mibs/MIBS/transition/TN-Y1564-MIB

602 lines
23 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- *****************************************************************
-- TN-Y1564-MIB.my : TN Y.1564 OAM MIB
--
-- Author : Krish
--
-- Copyright (c) 2014 by Transition Networks, Inc.
-- All rights reserved.
--
-- *************************************************************************************************
--
TN-Y1564-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
DisplayString, RowStatus, TruthValue FROM SNMPv2-TC
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
tnProducts FROM TRANSITION-SMI
InetAddressType,InetAddress FROM INET-ADDRESS-MIB
MacAddress FROM SNMPv2-TC
;
tnY1564MIB MODULE-IDENTITY
LAST-UPDATED "201408220000Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
" Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"The MIB provides functionalities for system user management in TN modules."
REVISION "201408220000Z"
DESCRIPTION
"Initial Revision of this module"
::= { tnProducts 154 }
tnY1564MIBNotifications OBJECT IDENTIFIER ::= { tnY1564MIB 1 }
tnY1564MIBObjects OBJECT IDENTIFIER ::= { tnY1564MIB 2 }
tnY1564MIBConformance OBJECT IDENTIFIER ::= { tnY1564MIB 3 }
--
-- sub Objects list
--
tnY1564CfgMgmt OBJECT IDENTIFIER ::= { tnY1564MIBObjects 1 }
tnY1564ReportMgmt OBJECT IDENTIFIER ::= { tnY1564MIBObjects 2 }
tnY1564ProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnY1564ProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides configuration of SOAM Maintenance Point.
"
::= { tnY1564CfgMgmt 1 }
tnY1564ProfileEntry OBJECT-TYPE
SYNTAX TnY1564ProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry in the table represents a configuration for local SOAM."
INDEX { IMPLIED tnY1564ProfileName }
::= { tnY1564ProfileTable 1 }
TnY1564ProfileEntry ::=
SEQUENCE{
tnY1564ProfileName SnmpAdminString,
tnY1564ProfileDescription DisplayString,
tnY1564DuelEnded TruthValue,
tnY1564DstOamAware TruthValue,
tnY1564TrafficType INTEGER,
tnY1564MegLevel INTEGER,
tnY1564FrameSize INTEGER,
tnY1564UserFrameSize INTEGER,
tnY1564DwellTime INTEGER,
tnY1564SacFLR INTEGER,
tnY1564SacFTD INTEGER,
tnY1564SacFDV INTEGER,
tnY1564CirEnable TruthValue,
tnY1564CirStepDuration INTEGER,
tnY1564CirDmInterval INTEGER,
tnY1564CirStepCount INTEGER,
tnY1564EirEnable TruthValue,
tnY1564EirDuration INTEGER,
tnY1564EirDmInterval INTEGER,
tnY1564TrafficPolicingEnable TruthValue,
tnY1564TrafficPolicingDuration INTEGER,
tnY1564TrafficPolicingDmInterval INTEGER,
tnY1564PerfTestEnable TruthValue,
tnY1564PerfTestDuration INTEGER,
tnY1564PerfTestUserDuration INTEGER,
tnY1564PerfTestDmInterval INTEGER,
tnY1564ProfileStatus RowStatus
}
tnY1564ProfileName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name, ASCII range 33-126, of this table."
::= { tnY1564ProfileEntry 1 }
tnY1564ProfileDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The description of this table."
::= { tnY1564ProfileEntry 2 }
tnY1564DuelEnded OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"For future use."
::= { tnY1564ProfileEntry 3 }
tnY1564DstOamAware OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When set, switch transmits Y.1731 DMM frames for delay measurements
and Y.1731 1DM frames when this is cleared. When Traffic Type is 'Y.1731 OAM',
switch transmits Y.1731 LBM frames as background traffic when DST is
configured as OAM-aware, and Y.1731 TST frames when not."
::= { tnY1564ProfileEntry 4 }
tnY1564TrafficType OBJECT-TYPE
SYNTAX INTEGER {
y1731Oam(1),
simCustomer(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "
When set to 'Y.1731 OAM', this switch transmits Y.1731
OAM PDUs as background traffic, and DST is OAM-aware
determines the PDU type. In the current version of the
software, only one ECE can be tested at a time in this mode.
When set to 'Simulated Customer', the software will generate
a traffic-pattern per ECE that will hit the ECE, and use
the ECE's counters to determine PASS/FAIL criteria.Besides
supporting simultaneous test of multiple ECEs,
'Simulated Customer' has the advantage that the tester can
see directly from the report if she has configured ECEs wrongly,
since the report will show per-ECE counters and fail if an ECE
under test is not hit as expected by the traffic pattern."
::= { tnY1564ProfileEntry 5 }
tnY1564MegLevel OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
three(3),
four(4),
five(5),
six(6),
seven(7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "
The MEG level used in generated Y.1731 OAM frames (both LBM/TST and DMM/1DM)."
::= { tnY1564ProfileEntry 6 }
tnY1564FrameSize OBJECT-TYPE
SYNTAX INTEGER {
bytes64(1),
bytes128(2),
bytes256(3),
bytes512(4),
bytes1024(5),
bytes1280(6),
bytes1518(7),
mtu(8),
userDefined(9)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "
Selects the frame size of the background traffic. The frame size
does not include possible C-tag(s) added to match the ECE. Besides
standard frame sizes there are two custom selections:
MTU - The UNI's MTU will be used for the background traffic.
User-defined - custom specification of a frame size of the background traffic.
Valid range is 64 to 10236 bytes.
"
::= { tnY1564ProfileEntry 7 }
tnY1564UserFrameSize OBJECT-TYPE
SYNTAX INTEGER(64..10236)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
User defined frame size of the background traffic.
Valid range is 64 to 10236 bytes.
"
::= { tnY1564ProfileEntry 8 }
tnY1564DwellTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
When a trial (a single step of a subtest) is executed, background
traffic is transmitted for a certain period of time. When that
period has elapsed, the Dwell Time determines how long to wait
before reading hardware counters and status in order to assess
the status of the trial. The required dwell time must be at least
the worst-case roundtrip time, and therefore a.o. depends on the
physical distance between the near and far ends.
Valid range is from 100 to 10000 in steps of 100 milliseconds
with a default of 500 milliseconds.
"
::= { tnY1564ProfileEntry 9 }
tnY1564SacFLR OBJECT-TYPE
SYNTAX INTEGER(0..1000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Defines the acceptable Frame Loss Ratio.
The Acceptable FLR is measured in permille. Setting this to
1000 effectively disables this check.The number is used in all
enabled subtests. Only delay measurement PDUs and green
background traffic undergoes FLR check. If the number of looped
green frames differs from the number of transmitted green frames
by more than the 'Acceptable FLR', the test is considered failing,
otherwise passing.If the EVC contains multiple ECEs that matches
on the same VLAN ID (UNI ingress) and the EVC uses 'Tx Lookup' equal
to 'VID-PCP', the NNI ingress rules count looped traffic per NNI
outer tag's PCP, and therefore provide more detailed information about
which ECE is failing, than if the EVC uses 'Tx Lookup' equal to 'VID',
where all looped traffic arriving on NNI is counted on the same ECE.
The disadvantage of the 'VID-PCP' method is that it uses more chip
resources than does the 'VID' method.
Valid range is from 0 to 1000 with a default of 0‰.
"
::= { tnY1564ProfileEntry 10 }
tnY1564SacFTD OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Defines the acceptable Frame Transfer Delay, measured in
milliseconds. If the highest observed frame transfer delay
exceeds this, the test fails.
Valid range is from 0 to 10000 with a default of 0 milliseconds.
A value of 0 disables this check.
"
::= { tnY1564ProfileEntry 11 }
tnY1564SacFDV OBJECT-TYPE
SYNTAX INTEGER(0..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Defines the acceptable Frame Delay Variation, measured in milliseconds.
If the highest observed frame delay variation exceeds this, the test fails.
Valid range is from 0 to 10000 with a default of 0 milliseconds.
A value of 0 disables this check.
"
::= { tnY1564ProfileEntry 12 }
tnY1564CirEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Set, to enable the CIR test."
::= { tnY1564ProfileEntry 13 }
tnY1564CirStepDuration OBJECT-TYPE
SYNTAX INTEGER(1..3600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Each step in the CIR configuration test applies background
traffic for this number of seconds.
Valid range is from 1 to 3600 with a default of 10 seconds.
"
::= { tnY1564ProfileEntry 14 }
tnY1564CirDmInterval OBJECT-TYPE
SYNTAX INTEGER(100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
A Y.1731 1DM or DMM frame (depending on type of test) is
transmitted every so many milliseconds, in order to perform
delay measurements (DM). The number should be selected so
that at least three DM frames are transmitted during a trial
in order to obtain delay variation results. After each trial
the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
Valid range is from 100 to 10000 in steps of 100 milliseconds
with a default of 500 milliseconds.
A value of 0 effectively disables transmission of DM frames,
which thereby indirectly disables the check against the SAC.
"
::= { tnY1564ProfileEntry 15 }
tnY1564CirStepCount OBJECT-TYPE
SYNTAX INTEGER(1..1000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
The number of steps (trials) used to reach CIR. If, for example,
Step Count is set to 4, four trials are executed. The first runs
at 25% of this ECEs share of CIR, the second at 50%, then 75%,
and finally 100%. A step count of 1 corresponds to executing
Y.1564's A.1 test (Simple CIR Validation Test). A step count
greater than 1 corresponds to executing Y.1564's A.2 test (Step Load CIR Test).
Valid range is from 1 to 1000 with a default of 4 steps.
"
::= { tnY1564ProfileEntry 16 }
tnY1564EirEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Set, to enable the EIR test."
::= { tnY1564ProfileEntry 17 }
tnY1564EirDuration OBJECT-TYPE
SYNTAX INTEGER(1..3600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
The EIR configuration test is executed in one single trial,
whose duration is configured with this parameter.
Valid range is from 1 to 3600 with a default of 10 seconds.
"
::= { tnY1564ProfileEntry 18 }
tnY1564EirDmInterval OBJECT-TYPE
SYNTAX INTEGER(100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
A Y.1731 1DM or DMM frame (depending on type of test) is
transmitted every so many milliseconds, in order to perform
delay measurements (DM). The number should be selected so
that at least three DM frames are transmitted during a trial
in order to obtain delay variation results. After each trial
the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
Valid range is from 100 to 10000 in steps of 100 milliseconds
with a default of 500 milliseconds.
A value of 0 effectively disables transmission of DM frames,
which thereby indirectly disables the check against the SAC.
"
::= { tnY1564ProfileEntry 19 }
tnY1564TrafficPolicingEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Set, to enable the Traffic Policing test."
::= { tnY1564ProfileEntry 20 }
tnY1564TrafficPolicingDuration OBJECT-TYPE
SYNTAX INTEGER(1..3600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
The Traffic Policing test is executed in one single trial,
whose duration is configured with this parameter.
Valid range is from 1 to 3600 with a default of 10 seconds.
"
::= { tnY1564ProfileEntry 21 }
tnY1564TrafficPolicingDmInterval OBJECT-TYPE
SYNTAX INTEGER(100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
A Y.1731 1DM or DMM frame (depending on type of test) is
transmitted every so many milliseconds, in order to perform
delay measurements (DM). The number should be selected so
that at least three DM frames are transmitted during a trial
in order to obtain delay variation results. After each trial
the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
Valid range is from 100 to 10000 in steps of 100 milliseconds
with a default of 500 milliseconds.
A value of 0 effectively disables transmission of DM frames,
which thereby indirectly disables the check against the SAC.
"
::= { tnY1564ProfileEntry 22 }
tnY1564PerfTestEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Set, to enable the Performance test."
::= { tnY1564ProfileEntry 23 }
tnY1564PerfTestDuration OBJECT-TYPE
SYNTAX INTEGER {
mins15(1),
hours2(2),
hours24(3),
userDefined(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
The performance test is executed in one single trial, whose
duration is configured with this parameter. There are
Y.1564-specified standard durations and a custom duration can be
specified by selecting User-defined Duration option.
"
::= { tnY1564ProfileEntry 24 }
tnY1564PerfTestUserDuration OBJECT-TYPE
SYNTAX INTEGER(1..86400)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
User defined duration. Valid range is from 1 to 86400 with a default of 900 seconds
"
::= { tnY1564ProfileEntry 25 }
tnY1564PerfTestDmInterval OBJECT-TYPE
SYNTAX INTEGER(100..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
A Y.1731 1DM or DMM frame (depending on type of test) is
transmitted every so many milliseconds, in order to perform
delay measurements (DM). The number should be selected so
that at least three DM frames are transmitted during a trial
in order to obtain delay variation results. After each trial
the measured FTD and FDV is compared against the SAC's Acceptable FLR, FTD, and FDV.
Valid range is from 100 to 10000 in steps of 100 milliseconds
with a default of 500 milliseconds.
A value of 0 effectively disables transmission of DM frames,
which thereby indirectly disables the check against the SAC.
"
::= { tnY1564ProfileEntry 26 }
tnY1564ProfileStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated.
"
::= { tnY1564ProfileEntry 27 }
-- ------------------------------------------------------
-- ------------------------------------------------------
-- ------------------------------------------------------
-- ------------------------------------------------------
tnY1564ReportTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnY1564ReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides configuration of SOAM Maintenance Point.
"
::= { tnY1564ReportMgmt 1 }
tnY1564ReportEntry OBJECT-TYPE
SYNTAX TnY1564ReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A entry in the table represents a configuration for local SOAM."
INDEX { IMPLIED tnY1564ReportName }
::= { tnY1564ReportTable 1 }
TnY1564ReportEntry ::=
SEQUENCE{
tnY1564ReportName SnmpAdminString,
tnY1564ReportDscr DisplayString,
tnY1564ReportTime DisplayString,
tnY1564ReportTftpAddrType InetAddressType,
tnY1564ReportTftpAddr InetAddress,
tnY1564ReportTestStatus INTEGER,
tnY1564ReportAction INTEGER
}
tnY1564ReportName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name, ASCII range 33-126, of this table."
::= { tnY1564ReportEntry 1 }
tnY1564ReportDscr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this table."
::= { tnY1564ReportEntry 2 }
tnY1564ReportTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (26))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this table."
::= { tnY1564ReportEntry 3 }
tnY1564ReportTftpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The tftp server IP address type. "
::= { tnY1564ReportEntry 4 }
tnY1564ReportTftpAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The tftp server IP address. "
::= { tnY1564ReportEntry 5 }
tnY1564ReportTestStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
executing(2),
cancelling(3),
cancelled(4),
passed(5),
failed(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
"
::= { tnY1564ReportEntry 6 }
tnY1564ReportAction OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
cancelTest(2),
saveReport(3),
deleteReport(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
"
::= { tnY1564ReportEntry 7 }
END