803 lines
27 KiB
Plaintext
803 lines
27 KiB
Plaintext
|
--
|
||
|
-- Accedian Enterprise Specific MIB
|
||
|
--
|
||
|
-- Copyright (c) 2005-2011, Accedian Networks, Inc.
|
||
|
-- All rights reserved.
|
||
|
--
|
||
|
-- The contents of this document are subject to change without notice.
|
||
|
--
|
||
|
|
||
|
|
||
|
ACD-REGULATOR-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE,
|
||
|
Gauge32, Counter32, Counter64, Unsigned32
|
||
|
FROM SNMPv2-SMI
|
||
|
DisplayString, TruthValue, DateAndTime, RowStatus
|
||
|
FROM SNMPv2-TC
|
||
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
||
|
FROM SNMPv2-CONF
|
||
|
acdMibs
|
||
|
FROM ACCEDIAN-SMI;
|
||
|
|
||
|
acdRegulator MODULE-IDENTITY
|
||
|
|
||
|
LAST-UPDATED "201110100100Z"
|
||
|
ORGANIZATION "Accedian Networks, Inc."
|
||
|
CONTACT-INFO
|
||
|
"Accedian Technical Assistance Center
|
||
|
Accedian Networks, Inc.
|
||
|
4878 Levy, suite 202
|
||
|
Saint-Laurent, Quebec Canada H4R 2P1
|
||
|
E-mail: support@accedian.com"
|
||
|
DESCRIPTION
|
||
|
"The Regulators database for this Accedian Networks device."
|
||
|
|
||
|
REVISION "201110100100Z" -- 10 October 2011
|
||
|
DESCRIPTION
|
||
|
"Add acdRegulatorTableLastChangeTid."
|
||
|
|
||
|
REVISION "201011100100Z" -- 10 November 2010
|
||
|
DESCRIPTION
|
||
|
"Add compliance section."
|
||
|
|
||
|
REVISION "200805010100Z" -- 1 May 2008
|
||
|
DESCRIPTION
|
||
|
"Add RowStatus in acdRegulatorTable table."
|
||
|
|
||
|
REVISION "200802060100Z" -- 6 Feb 2008
|
||
|
DESCRIPTION
|
||
|
"Add support for history table."
|
||
|
|
||
|
REVISION "200703280100Z" -- 28 March 2007
|
||
|
DESCRIPTION
|
||
|
"Initial version of MIB module ACD-REGULATOR-MIB."
|
||
|
|
||
|
::= { acdMibs 6 }
|
||
|
|
||
|
acdRegulatorNotifications OBJECT IDENTIFIER ::= { acdRegulator 4 }
|
||
|
acdRegulatorMIBObjects OBJECT IDENTIFIER ::= { acdRegulator 5 }
|
||
|
acdRegulatorConformance OBJECT IDENTIFIER ::= { acdRegulator 6 }
|
||
|
|
||
|
acdRegulatorTableTid OBJECT IDENTIFIER ::= { acdRegulatorMIBObjects 1 }
|
||
|
|
||
|
-----------------------------------------------------------------------
|
||
|
-- The Regulators table
|
||
|
-- This table contains all Regulators.
|
||
|
---------------------------------------------------------------------------
|
||
|
|
||
|
acdRegulatorTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF AcdRegulatorEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Table of all Regulators"
|
||
|
::= { acdRegulator 1 }
|
||
|
|
||
|
acdRegulatorEntry OBJECT-TYPE
|
||
|
SYNTAX AcdRegulatorEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A Regulator is a two rates three colors engine to regulate a
|
||
|
given traffic."
|
||
|
INDEX { acdRegulatorID }
|
||
|
::= { acdRegulatorTable 1 }
|
||
|
|
||
|
|
||
|
AcdRegulatorEntry ::= SEQUENCE {
|
||
|
acdRegulatorID Unsigned32,
|
||
|
acdRegulatorName DisplayString,
|
||
|
acdRegulatorCir Unsigned32,
|
||
|
acdRegulatorCbs Unsigned32,
|
||
|
acdRegulatorEir Unsigned32,
|
||
|
acdRegulatorEbs Unsigned32,
|
||
|
acdRegulatorIsBlind TruthValue,
|
||
|
acdRegulatorIsCouple TruthValue,
|
||
|
acdRegulatorRowStatus RowStatus
|
||
|
|
||
|
}
|
||
|
|
||
|
acdRegulatorID OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Unique value for each regulator entry. Its value ranges from 1 to
|
||
|
MAXINT (4 bytes). "
|
||
|
::= { acdRegulatorEntry 1 }
|
||
|
|
||
|
acdRegulatorName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (1..31))
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is a string to identify the regulator."
|
||
|
::= { acdRegulatorEntry 2 }
|
||
|
|
||
|
acdRegulatorCir OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The committed information rate."
|
||
|
DEFVAL { 20000 }
|
||
|
::= { acdRegulatorEntry 3 }
|
||
|
|
||
|
acdRegulatorCbs OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "Kbytes"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The committed burst size."
|
||
|
DEFVAL { 8 }
|
||
|
::= { acdRegulatorEntry 4 }
|
||
|
|
||
|
acdRegulatorEir OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The excess information rate."
|
||
|
DEFVAL { 1000 }
|
||
|
::= { acdRegulatorEntry 5 }
|
||
|
|
||
|
acdRegulatorEbs OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "Kbytes"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The excess burst size."
|
||
|
DEFVAL { 8 }
|
||
|
::= { acdRegulatorEntry 6 }
|
||
|
|
||
|
acdRegulatorIsBlind OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable the pre-marking color processing."
|
||
|
DEFVAL { false }
|
||
|
::= { acdRegulatorEntry 7 }
|
||
|
|
||
|
acdRegulatorIsCouple OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable the coupling flag in this regulator."
|
||
|
DEFVAL { false }
|
||
|
::= { acdRegulatorEntry 8 }
|
||
|
|
||
|
acdRegulatorRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"All columns must have a valid value before a row can be activated. To
|
||
|
create a new regulator you shall provide the a unique name for
|
||
|
an empty row with the RowStatus set to Create and Go. To delete the
|
||
|
row you need to set the RowStatus to destroy."
|
||
|
::= { acdRegulatorEntry 9 }
|
||
|
|
||
|
---------------------------------------------------------------------------
|
||
|
-- The Regulator Counters table
|
||
|
-- This table contains all counters associated with each regulator.
|
||
|
---------------------------------------------------------------------------
|
||
|
|
||
|
acdRegulatorStatsTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF AcdRegulatorStatsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Table of all counters associated with each regulator."
|
||
|
::= { acdRegulator 2 }
|
||
|
|
||
|
acdRegulatorStatsEntry OBJECT-TYPE
|
||
|
SYNTAX AcdRegulatorStatsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An Entry consists of statitics related to a regulator entry."
|
||
|
INDEX { acdRegulatorStatsID }
|
||
|
::= { acdRegulatorStatsTable 1 }
|
||
|
|
||
|
|
||
|
AcdRegulatorStatsEntry ::= SEQUENCE {
|
||
|
acdRegulatorStatsID Unsigned32,
|
||
|
acdRegulatorStatsAcceptOctets Counter32,
|
||
|
acdRegulatorStatsAcceptOverflowOctets Counter32,
|
||
|
acdRegulatorStatsAcceptHCOctets Counter64,
|
||
|
acdRegulatorStatsAcceptPkts Counter32,
|
||
|
acdRegulatorStatsAcceptOverflowPkts Counter32,
|
||
|
acdRegulatorStatsAcceptHCPkts Counter64,
|
||
|
acdRegulatorStatsAcceptRate Gauge32,
|
||
|
acdRegulatorStatsDropOctets Counter32,
|
||
|
acdRegulatorStatsDropOverflowOctets Counter32,
|
||
|
acdRegulatorStatsDropHCOctets Counter64,
|
||
|
acdRegulatorStatsDropPkts Counter32,
|
||
|
acdRegulatorStatsDropOverflowPkts Counter32,
|
||
|
acdRegulatorStatsDropHCPkts Counter64,
|
||
|
acdRegulatorStatsDropRate Gauge32
|
||
|
}
|
||
|
|
||
|
acdRegulatorStatsID OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Unique value for each regulator entry. Its value ranges from 1 to
|
||
|
MAXINT (4 bytes)."
|
||
|
::= { acdRegulatorStatsEntry 1 }
|
||
|
|
||
|
acdRegulatorStatsAcceptOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator. This is a
|
||
|
32 bits counter. Combined with acdRegulatorStatsAcceptOverflowOctets,
|
||
|
it provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorStatsAcceptHCOctets."
|
||
|
::= { acdRegulatorStatsEntry 2 }
|
||
|
|
||
|
acdRegulatorStatsAcceptOverflowOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorStatsAcceptOctets
|
||
|
counter has overflowed. This is a 32 bits counter. Combined with
|
||
|
acdRegulatorStatsAcceptOctets, it provides the equivalent of the
|
||
|
64 bits counter acdRegulatorStatsAccpetHCOctets."
|
||
|
::= { acdRegulatorStatsEntry 3 }
|
||
|
|
||
|
acdRegulatorStatsAcceptHCOctets OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator."
|
||
|
::= { acdRegulatorStatsEntry 4 }
|
||
|
|
||
|
acdRegulatorStatsAcceptPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator. This is a
|
||
|
32 bits counter. Combined with acdRegulatorStatsAcceptOverflowPkts,
|
||
|
it provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorStatsAcceptHCPkts."
|
||
|
::= { acdRegulatorStatsEntry 5 }
|
||
|
|
||
|
acdRegulatorStatsAcceptOverflowPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorStatsAcceptPkts
|
||
|
counter has overflowed. This is a 32 bits counter. Combined with
|
||
|
acdRegulatorStatsAcceptPkts, it provides the equivalent of the
|
||
|
64 bits counter acdRegulatorStatsAcceptHCPkts."
|
||
|
::= { acdRegulatorStatsEntry 6 }
|
||
|
|
||
|
acdRegulatorStatsAcceptHCPkts OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator."
|
||
|
::= { acdRegulatorStatsEntry 7 }
|
||
|
|
||
|
acdRegulatorStatsAcceptRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The accept rate."
|
||
|
::= { acdRegulatorStatsEntry 8 }
|
||
|
|
||
|
acdRegulatorStatsDropOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator. This is a
|
||
|
32 bits counter. Combined with acdRegulatorStatsDropOverflowOctets,
|
||
|
it provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorStatsDropHCOctets."
|
||
|
::= { acdRegulatorStatsEntry 9 }
|
||
|
|
||
|
acdRegulatorStatsDropOverflowOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorStatsDropOctets
|
||
|
counter has overflowed. This is a 32 bits counter. Combined with
|
||
|
acdRegulatorStatsDropOctets, it provides the equivalent of the
|
||
|
64 bits counter acdRegulatorStatsDropHCOctets."
|
||
|
::= { acdRegulatorStatsEntry 10 }
|
||
|
|
||
|
acdRegulatorStatsDropHCOctets OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator."
|
||
|
::= { acdRegulatorStatsEntry 11 }
|
||
|
|
||
|
acdRegulatorStatsDropPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator. This is a
|
||
|
32 bits counter. Combined with acdRegulatorStatsDropOverflowPkts,
|
||
|
it provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorStatsDropHCPkts."
|
||
|
::= { acdRegulatorStatsEntry 12 }
|
||
|
|
||
|
acdRegulatorStatsDropOverflowPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorStatsDropPkts
|
||
|
counter has overflowed. This is a 32 bits counter. Combined with
|
||
|
acdRegulatorStatsDropPkts, it provides the equivalent of the
|
||
|
64 bits counter acdRegulatorStatsDropHCPkts."
|
||
|
::= { acdRegulatorStatsEntry 13 }
|
||
|
|
||
|
acdRegulatorStatsDropHCPkts OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator."
|
||
|
::= { acdRegulatorStatsEntry 14 }
|
||
|
|
||
|
acdRegulatorStatsDropRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The drop rate."
|
||
|
::= { acdRegulatorStatsEntry 15 }
|
||
|
|
||
|
---------------------------------------------------------------------------
|
||
|
-- The Regulator History group
|
||
|
|
||
|
-- The Regulator History group records periodic statistical samples
|
||
|
-- from a regulator and stores them for later retrieval.
|
||
|
|
||
|
---------------------------------------------------------------------------
|
||
|
|
||
|
acdRegulatorHistStatsTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF AcdRegulatorHistStatsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Table of all counters associated with each regulator."
|
||
|
::= { acdRegulator 3 }
|
||
|
|
||
|
acdRegulatorHistStatsEntry OBJECT-TYPE
|
||
|
SYNTAX AcdRegulatorHistStatsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An Entry consists of statitics related to a regulator entry."
|
||
|
INDEX { acdRegulatorHistStatsID , acdRegulatorHistStatsSampleIndex }
|
||
|
::= { acdRegulatorHistStatsTable 1 }
|
||
|
|
||
|
|
||
|
AcdRegulatorHistStatsEntry ::= SEQUENCE {
|
||
|
acdRegulatorHistStatsID Unsigned32,
|
||
|
acdRegulatorHistStatsSampleIndex Unsigned32,
|
||
|
acdRegulatorHistStatsStatus INTEGER,
|
||
|
acdRegulatorHistStatsDuration Unsigned32,
|
||
|
acdRegulatorHistStatsIntervalEnd DateAndTime,
|
||
|
acdRegulatorHistStatsAcceptOctets Counter32,
|
||
|
acdRegulatorHistStatsAcceptOverflowOctets Counter32,
|
||
|
acdRegulatorHistStatsAcceptHCOctets Counter64,
|
||
|
acdRegulatorHistStatsAcceptPkts Counter32,
|
||
|
acdRegulatorHistStatsAcceptOverflowPkts Counter32,
|
||
|
acdRegulatorHistStatsAcceptHCPkts Counter64,
|
||
|
acdRegulatorHistStatsAcceptAvgRate Gauge32,
|
||
|
acdRegulatorHistStatsAcceptMinRate Gauge32,
|
||
|
acdRegulatorHistStatsAcceptMaxRate Gauge32,
|
||
|
acdRegulatorHistStatsDropOctets Counter32,
|
||
|
acdRegulatorHistStatsDropOverflowOctets Counter32,
|
||
|
acdRegulatorHistStatsDropHCOctets Counter64,
|
||
|
acdRegulatorHistStatsDropPkts Counter32,
|
||
|
acdRegulatorHistStatsDropOverflowPkts Counter32,
|
||
|
acdRegulatorHistStatsDropHCPkts Counter64,
|
||
|
acdRegulatorHistStatsDropAvgRate Gauge32,
|
||
|
acdRegulatorHistStatsDropMinRate Gauge32,
|
||
|
acdRegulatorHistStatsDropMaxRate Gauge32
|
||
|
}
|
||
|
|
||
|
acdRegulatorHistStatsID OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Unique value for each regulator entry. Its value ranges from 1 to
|
||
|
MAXINT (4 bytes)."
|
||
|
::= { acdRegulatorHistStatsEntry 1 }
|
||
|
|
||
|
acdRegulatorHistStatsSampleIndex OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An index that uniquely identifies the particular sample this entry
|
||
|
represents among all samples associated with the same regulator
|
||
|
instance. This index starts at 1 and increases by one as each new
|
||
|
sample."
|
||
|
::= { acdRegulatorHistStatsEntry 2 }
|
||
|
|
||
|
acdRegulatorHistStatsStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
valid(1),
|
||
|
invalid(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of this acdRegulatorHistStats entry."
|
||
|
::= { acdRegulatorHistStatsEntry 3 }
|
||
|
|
||
|
acdRegulatorHistStatsDuration OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The interval in seconds over which the data is sampled for this entry."
|
||
|
::= { acdRegulatorHistStatsEntry 4 }
|
||
|
|
||
|
acdRegulatorHistStatsIntervalEnd OBJECT-TYPE
|
||
|
SYNTAX DateAndTime
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is the time of the end of this entry."
|
||
|
::= { acdRegulatorHistStatsEntry 5 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator during this
|
||
|
sampling interval. This is a 32 bits counter. Combined with
|
||
|
acdRegulatorHistStatsAcceptOverflowOctets, it provides the equivalent
|
||
|
of the 64 bits counter acdRegulatorHistStatsAcceptHCOctets."
|
||
|
::= { acdRegulatorHistStatsEntry 6 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptOverflowOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorHistStatsAcceptOctets
|
||
|
counter has overflowed during this sampling interval. This is a
|
||
|
32 bits counter. Combined with acdRegulatorHistStatsAcceptOctets,
|
||
|
it provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorHistStatsAcceptHCOctets."
|
||
|
::= { acdRegulatorHistStatsEntry 7 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptHCOctets OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator during this
|
||
|
sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 8 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator during this
|
||
|
sampling interval. This is a 32 bits counter. Combined with
|
||
|
acdRegulatorHistStatsAcceptOverflowPkts, it provides the equivalent
|
||
|
of the 64 bits counter acdRegulatorHistStatsAcceptHCPkts."
|
||
|
::= { acdRegulatorHistStatsEntry 9 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptOverflowPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorHistStatsAcceptPkts
|
||
|
counter has overflowed during this sampling interval. This is a
|
||
|
32 bits counter. Combined with acdRegulatorHistStatsAcceptPkts, it
|
||
|
provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorHistStatsAcceptHCPkts."
|
||
|
::= { acdRegulatorHistStatsEntry 10 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptHCPkts OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator during this
|
||
|
sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 11 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptAvgRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The average accept rate during this sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 12 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptMinRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum accept rate during this sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 13 }
|
||
|
|
||
|
acdRegulatorHistStatsAcceptMaxRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum accept rate during this sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 14 }
|
||
|
|
||
|
acdRegulatorHistStatsDropOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator during this
|
||
|
sampling interval. This is a 32 bits counter. Combined the overflow,
|
||
|
counter it provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorHistStatsDropHCOctets."
|
||
|
::= { acdRegulatorHistStatsEntry 15 }
|
||
|
|
||
|
acdRegulatorHistStatsDropOverflowOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorHistStatsDropOctets
|
||
|
counter has overflowed during this sampling interval. This is a
|
||
|
32 bits counter. Combined with acdRegulatorHistStatsDropOctets, it
|
||
|
provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorHistStatsDropHCOctets."
|
||
|
::= { acdRegulatorHistStatsEntry 16 }
|
||
|
|
||
|
acdRegulatorHistStatsDropHCOctets OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of octets received by this regulator during this
|
||
|
sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 17 }
|
||
|
|
||
|
acdRegulatorHistStatsDropPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator during this
|
||
|
sampling interval. This is a 32 bits counter. Combined with
|
||
|
acdRegulatorHistStatsDropOverflowPkts, it provides the equivalent of
|
||
|
the 64 bits counter acdRegulatorHistStatsDropHCPkts."
|
||
|
::= { acdRegulatorHistStatsEntry 18 }
|
||
|
|
||
|
acdRegulatorHistStatsDropOverflowPkts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
UNITS "Packets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of times the associated acdRegulatorHistStatsDropPkts
|
||
|
counter has overflowed during this sampling interval. This is a
|
||
|
32 bits counter. Combined with acdRegulatorHistStatsDropPkts, it
|
||
|
provides the equivalent of the 64 bits counter
|
||
|
acdRegulatorHistStatsDropHCPkts."
|
||
|
::= { acdRegulatorHistStatsEntry 19 }
|
||
|
|
||
|
acdRegulatorHistStatsDropHCPkts OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
UNITS "Octets"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The total number of packets received by this regulator during this
|
||
|
sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 20 }
|
||
|
|
||
|
acdRegulatorHistStatsDropAvgRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The average drop rate during this sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 21 }
|
||
|
|
||
|
acdRegulatorHistStatsDropMinRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum drop rate during this sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 22 }
|
||
|
|
||
|
acdRegulatorHistStatsDropMaxRate OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "Kbps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum drop rate during this sampling interval."
|
||
|
::= { acdRegulatorHistStatsEntry 23 }
|
||
|
|
||
|
---------------------------------------------------------------------------
|
||
|
-- Transaction ID Information
|
||
|
---------------------------------------------------------------------------
|
||
|
|
||
|
acdRegulatorTableLastChangeTid OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is the transaction ID of the last change of the acdRegulatorTable
|
||
|
table. If this value is different since the last read this is indicate
|
||
|
a table change."
|
||
|
::= { acdRegulatorTableTid 1 }
|
||
|
|
||
|
---------------------------------------------------------------------------
|
||
|
-- ACD-REGULATOR-MIB Module - Conformance Information
|
||
|
---------------------------------------------------------------------------
|
||
|
|
||
|
acdRegulatorCompliances OBJECT IDENTIFIER ::= { acdRegulatorConformance 1 }
|
||
|
acdRegulatorGroups OBJECT IDENTIFIER ::= { acdRegulatorConformance 2 }
|
||
|
|
||
|
---------------------------------------------------------------------------
|
||
|
-- Units of conformance
|
||
|
---------------------------------------------------------------------------
|
||
|
|
||
|
acdRegulatorGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
acdRegulatorName,
|
||
|
acdRegulatorCir,
|
||
|
acdRegulatorCbs,
|
||
|
acdRegulatorEir,
|
||
|
acdRegulatorEbs,
|
||
|
acdRegulatorIsBlind,
|
||
|
acdRegulatorIsCouple,
|
||
|
acdRegulatorRowStatus
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Objects for the Regulator configurtion Group."
|
||
|
::= { acdRegulatorGroups 1 }
|
||
|
|
||
|
acdRegulatorStatsGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
acdRegulatorStatsAcceptOctets,
|
||
|
acdRegulatorStatsAcceptOverflowOctets,
|
||
|
acdRegulatorStatsAcceptHCOctets,
|
||
|
acdRegulatorStatsAcceptPkts,
|
||
|
acdRegulatorStatsAcceptOverflowPkts,
|
||
|
acdRegulatorStatsAcceptHCPkts,
|
||
|
acdRegulatorStatsAcceptRate,
|
||
|
acdRegulatorStatsDropOctets,
|
||
|
acdRegulatorStatsDropOverflowOctets,
|
||
|
acdRegulatorStatsDropHCOctets,
|
||
|
acdRegulatorStatsDropPkts,
|
||
|
acdRegulatorStatsDropOverflowPkts,
|
||
|
acdRegulatorStatsDropHCPkts,
|
||
|
acdRegulatorStatsDropRate
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Objects for the Regulator statistics Group."
|
||
|
::= { acdRegulatorGroups 2 }
|
||
|
|
||
|
acdRegulatorHistStatsGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
acdRegulatorHistStatsStatus,
|
||
|
acdRegulatorHistStatsDuration,
|
||
|
acdRegulatorHistStatsIntervalEnd,
|
||
|
acdRegulatorHistStatsAcceptOctets,
|
||
|
acdRegulatorHistStatsAcceptOverflowOctets,
|
||
|
acdRegulatorHistStatsAcceptHCOctets,
|
||
|
acdRegulatorHistStatsAcceptPkts,
|
||
|
acdRegulatorHistStatsAcceptOverflowPkts,
|
||
|
acdRegulatorHistStatsAcceptHCPkts,
|
||
|
acdRegulatorHistStatsAcceptAvgRate,
|
||
|
acdRegulatorHistStatsAcceptMinRate,
|
||
|
acdRegulatorHistStatsAcceptMaxRate,
|
||
|
acdRegulatorHistStatsDropOctets,
|
||
|
acdRegulatorHistStatsDropOverflowOctets,
|
||
|
acdRegulatorHistStatsDropHCOctets,
|
||
|
acdRegulatorHistStatsDropPkts,
|
||
|
acdRegulatorHistStatsDropOverflowPkts,
|
||
|
acdRegulatorHistStatsDropHCPkts,
|
||
|
acdRegulatorHistStatsDropAvgRate,
|
||
|
acdRegulatorHistStatsDropMinRate,
|
||
|
acdRegulatorHistStatsDropMaxRate
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Objects for the Regulator history statistics Group."
|
||
|
::= { acdRegulatorGroups 3 }
|
||
|
|
||
|
acdRegulatorTidGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
acdRegulatorTableLastChangeTid
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"List of scalars to monitior changes in tables."
|
||
|
::= { acdRegulatorGroups 4 }
|
||
|
|
||
|
acdPaaCompliance MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for support of the ACD-REGULATOR-MIB module."
|
||
|
MODULE
|
||
|
MANDATORY-GROUPS {
|
||
|
acdRegulatorGroup,
|
||
|
acdRegulatorStatsGroup,
|
||
|
acdRegulatorHistStatsGroup,
|
||
|
acdRegulatorTidGroup
|
||
|
}
|
||
|
|
||
|
OBJECT acdRegulatorRowStatus
|
||
|
SYNTAX RowStatus { active(1) }
|
||
|
WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) }
|
||
|
DESCRIPTION "Support for createAndWait is not required."
|
||
|
|
||
|
::= { acdRegulatorCompliances 1 }
|
||
|
|
||
|
|
||
|
END
|