803 lines
		
	
	
		
			27 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			803 lines
		
	
	
		
			27 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| --
 | |
| -- Accedian Enterprise Specific MIB
 | |
| --
 | |
| -- Copyright (c) 2005-2011, Accedian Networks, Inc.
 | |
| -- All rights reserved.
 | |
| --
 | |
| -- The contents of this document are subject to change without notice.
 | |
| --
 | |
| 
 | |
| 
 | |
| ACD-REGULATOR-MIB DEFINITIONS ::= BEGIN
 | |
| 
 | |
| IMPORTS
 | |
|     MODULE-IDENTITY, OBJECT-TYPE,
 | |
|     Gauge32, Counter32, Counter64, Unsigned32
 | |
|         FROM SNMPv2-SMI
 | |
|     DisplayString, TruthValue, DateAndTime, RowStatus
 | |
|         FROM SNMPv2-TC
 | |
|     MODULE-COMPLIANCE, OBJECT-GROUP
 | |
|         FROM SNMPv2-CONF
 | |
|     acdMibs
 | |
|         FROM ACCEDIAN-SMI;
 | |
| 
 | |
| acdRegulator MODULE-IDENTITY
 | |
| 
 | |
|     LAST-UPDATED "201110100100Z"
 | |
|     ORGANIZATION "Accedian Networks, Inc."
 | |
|     CONTACT-INFO
 | |
|             "Accedian Technical Assistance Center
 | |
|              Accedian Networks, Inc.
 | |
|              4878 Levy, suite 202
 | |
|              Saint-Laurent, Quebec Canada H4R 2P1
 | |
|              E-mail: support@accedian.com"
 | |
|     DESCRIPTION
 | |
|             "The Regulators database for this Accedian Networks device."
 | |
| 
 | |
|     REVISION "201110100100Z"        -- 10 October 2011
 | |
|     DESCRIPTION
 | |
|             "Add acdRegulatorTableLastChangeTid."
 | |
| 
 | |
|     REVISION "201011100100Z"        -- 10 November 2010
 | |
|     DESCRIPTION
 | |
|             "Add compliance section."
 | |
| 
 | |
|     REVISION "200805010100Z"        -- 1 May 2008
 | |
|     DESCRIPTION
 | |
|             "Add RowStatus in acdRegulatorTable table."
 | |
| 
 | |
|     REVISION "200802060100Z"        -- 6 Feb 2008
 | |
|     DESCRIPTION
 | |
|             "Add support for history table."
 | |
| 
 | |
|     REVISION "200703280100Z"        -- 28 March 2007
 | |
|     DESCRIPTION
 | |
|             "Initial version of MIB module ACD-REGULATOR-MIB."
 | |
| 
 | |
|     ::= { acdMibs 6 }
 | |
| 
 | |
| acdRegulatorNotifications   OBJECT IDENTIFIER ::= { acdRegulator 4 }
 | |
| acdRegulatorMIBObjects      OBJECT IDENTIFIER ::= { acdRegulator 5 }
 | |
| acdRegulatorConformance     OBJECT IDENTIFIER ::= { acdRegulator 6 }
 | |
| 
 | |
| acdRegulatorTableTid        OBJECT IDENTIFIER ::= { acdRegulatorMIBObjects 1 }
 | |
| 
 | |
| -----------------------------------------------------------------------
 | |
|  -- The Regulators table
 | |
|  -- This table contains all Regulators.
 | |
| ---------------------------------------------------------------------------
 | |
| 
 | |
| acdRegulatorTable OBJECT-TYPE
 | |
|     SYNTAX      SEQUENCE OF AcdRegulatorEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|             "Table of all Regulators"
 | |
|     ::= { acdRegulator 1 }
 | |
| 
 | |
| acdRegulatorEntry OBJECT-TYPE
 | |
|     SYNTAX      AcdRegulatorEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|             "A Regulator is a two rates three colors engine to regulate a
 | |
|              given traffic."
 | |
|     INDEX   { acdRegulatorID }
 | |
|     ::=  { acdRegulatorTable 1 }
 | |
| 
 | |
| 
 | |
| AcdRegulatorEntry ::= SEQUENCE {
 | |
|     acdRegulatorID              Unsigned32,
 | |
|     acdRegulatorName            DisplayString,
 | |
|     acdRegulatorCir             Unsigned32,
 | |
|     acdRegulatorCbs             Unsigned32,
 | |
|     acdRegulatorEir             Unsigned32,
 | |
|     acdRegulatorEbs             Unsigned32,
 | |
|     acdRegulatorIsBlind         TruthValue,
 | |
|     acdRegulatorIsCouple        TruthValue,
 | |
|     acdRegulatorRowStatus       RowStatus
 | |
| 
 | |
| }
 | |
| 
 | |
| acdRegulatorID  OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Unique value for each regulator entry. Its value ranges from 1 to
 | |
|         MAXINT (4 bytes). "
 | |
|    ::= { acdRegulatorEntry 1 }
 | |
| 
 | |
| acdRegulatorName OBJECT-TYPE
 | |
|     SYNTAX      DisplayString (SIZE (1..31))
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "This is a string to identify the regulator."
 | |
|     ::= { acdRegulatorEntry 2 }
 | |
| 
 | |
| acdRegulatorCir OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The committed information rate."
 | |
|     DEFVAL      { 20000 }
 | |
|    ::= { acdRegulatorEntry 3 }
 | |
| 
 | |
| acdRegulatorCbs OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     UNITS       "Kbytes"
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The committed burst size."
 | |
|     DEFVAL      { 8 }
 | |
|    ::= { acdRegulatorEntry 4 }
 | |
| 
 | |
| acdRegulatorEir OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The excess information rate."
 | |
|     DEFVAL      { 1000 }
 | |
|    ::= { acdRegulatorEntry 5 }
 | |
| 
 | |
| acdRegulatorEbs OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     UNITS       "Kbytes"
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The excess burst size."
 | |
|     DEFVAL      { 8 }
 | |
|    ::= { acdRegulatorEntry 6 }
 | |
| 
 | |
| acdRegulatorIsBlind OBJECT-TYPE
 | |
|     SYNTAX      TruthValue
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Enable or disable the pre-marking color processing."
 | |
|     DEFVAL      { false }
 | |
|     ::= { acdRegulatorEntry 7 }
 | |
| 
 | |
| acdRegulatorIsCouple OBJECT-TYPE
 | |
|     SYNTAX      TruthValue
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Enable or disable the coupling flag in this regulator."
 | |
|     DEFVAL      { false }
 | |
|     ::= { acdRegulatorEntry 8 }
 | |
| 
 | |
| acdRegulatorRowStatus OBJECT-TYPE
 | |
|     SYNTAX      RowStatus
 | |
|     MAX-ACCESS  read-create
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "All columns must have a valid value before a row can be activated. To
 | |
|         create a new regulator you shall provide the a unique name for
 | |
|         an empty row with the RowStatus set to Create and Go. To delete the
 | |
|         row you need to set the RowStatus to destroy."
 | |
|     ::= { acdRegulatorEntry 9 }
 | |
| 
 | |
| ---------------------------------------------------------------------------
 | |
|  -- The Regulator Counters table
 | |
|  -- This table contains all counters associated with each regulator.
 | |
| ---------------------------------------------------------------------------
 | |
| 
 | |
| acdRegulatorStatsTable OBJECT-TYPE
 | |
|     SYNTAX      SEQUENCE OF AcdRegulatorStatsEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|             "Table of all counters associated with each regulator."
 | |
|     ::= { acdRegulator 2 }
 | |
| 
 | |
| acdRegulatorStatsEntry OBJECT-TYPE
 | |
|     SYNTAX      AcdRegulatorStatsEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|             "An Entry consists of statitics related to a regulator entry."
 | |
|     INDEX   { acdRegulatorStatsID }
 | |
|     ::=  { acdRegulatorStatsTable 1 }
 | |
| 
 | |
| 
 | |
| AcdRegulatorStatsEntry ::= SEQUENCE {
 | |
|     acdRegulatorStatsID                     Unsigned32,
 | |
|     acdRegulatorStatsAcceptOctets           Counter32,
 | |
|     acdRegulatorStatsAcceptOverflowOctets   Counter32,
 | |
|     acdRegulatorStatsAcceptHCOctets         Counter64,
 | |
|     acdRegulatorStatsAcceptPkts             Counter32,
 | |
|     acdRegulatorStatsAcceptOverflowPkts     Counter32,
 | |
|     acdRegulatorStatsAcceptHCPkts           Counter64,
 | |
|     acdRegulatorStatsAcceptRate             Gauge32,
 | |
|     acdRegulatorStatsDropOctets             Counter32,
 | |
|     acdRegulatorStatsDropOverflowOctets     Counter32,
 | |
|     acdRegulatorStatsDropHCOctets           Counter64,
 | |
|     acdRegulatorStatsDropPkts               Counter32,
 | |
|     acdRegulatorStatsDropOverflowPkts       Counter32,
 | |
|     acdRegulatorStatsDropHCPkts             Counter64,
 | |
|     acdRegulatorStatsDropRate               Gauge32
 | |
| }
 | |
| 
 | |
| acdRegulatorStatsID  OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Unique value for each regulator entry. Its value ranges from 1 to
 | |
|         MAXINT (4 bytes)."
 | |
|    ::= { acdRegulatorStatsEntry 1 }
 | |
| 
 | |
| acdRegulatorStatsAcceptOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator. This is a
 | |
|          32 bits counter. Combined with acdRegulatorStatsAcceptOverflowOctets,
 | |
|          it provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorStatsAcceptHCOctets."
 | |
|     ::= { acdRegulatorStatsEntry 2 }
 | |
| 
 | |
| acdRegulatorStatsAcceptOverflowOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorStatsAcceptOctets
 | |
|          counter has overflowed. This is a 32 bits counter. Combined with 
 | |
|          acdRegulatorStatsAcceptOctets, it provides the equivalent of the
 | |
|          64 bits counter acdRegulatorStatsAccpetHCOctets."
 | |
|     ::= { acdRegulatorStatsEntry 3 }
 | |
| 
 | |
| acdRegulatorStatsAcceptHCOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator."
 | |
|     ::= { acdRegulatorStatsEntry 4 }
 | |
| 
 | |
| acdRegulatorStatsAcceptPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator. This is a
 | |
|          32 bits counter. Combined with acdRegulatorStatsAcceptOverflowPkts,
 | |
|          it provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorStatsAcceptHCPkts."
 | |
|     ::= { acdRegulatorStatsEntry 5 }
 | |
| 
 | |
| acdRegulatorStatsAcceptOverflowPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorStatsAcceptPkts
 | |
|          counter has overflowed. This is a 32 bits counter. Combined with 
 | |
|          acdRegulatorStatsAcceptPkts, it provides the equivalent of the
 | |
|          64 bits counter acdRegulatorStatsAcceptHCPkts."
 | |
|     ::= { acdRegulatorStatsEntry 6 }
 | |
| 
 | |
| acdRegulatorStatsAcceptHCPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator."
 | |
|     ::= { acdRegulatorStatsEntry 7 }
 | |
| 
 | |
| acdRegulatorStatsAcceptRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The accept rate."
 | |
|     ::= { acdRegulatorStatsEntry 8 }
 | |
| 
 | |
| acdRegulatorStatsDropOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator. This is a
 | |
|          32 bits counter. Combined with acdRegulatorStatsDropOverflowOctets,
 | |
|          it provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorStatsDropHCOctets."
 | |
|     ::= { acdRegulatorStatsEntry 9 }
 | |
| 
 | |
| acdRegulatorStatsDropOverflowOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorStatsDropOctets
 | |
|          counter has overflowed. This is a 32 bits counter. Combined with 
 | |
|          acdRegulatorStatsDropOctets, it provides the equivalent of the
 | |
|          64 bits counter acdRegulatorStatsDropHCOctets."
 | |
|     ::= { acdRegulatorStatsEntry 10 }
 | |
| 
 | |
| acdRegulatorStatsDropHCOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator."
 | |
|     ::= { acdRegulatorStatsEntry 11 }
 | |
| 
 | |
| acdRegulatorStatsDropPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator. This is a
 | |
|          32 bits counter. Combined with acdRegulatorStatsDropOverflowPkts,
 | |
|          it provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorStatsDropHCPkts."
 | |
|     ::= { acdRegulatorStatsEntry 12 }
 | |
| 
 | |
| acdRegulatorStatsDropOverflowPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorStatsDropPkts
 | |
|          counter has overflowed. This is a 32 bits counter. Combined with 
 | |
|          acdRegulatorStatsDropPkts, it provides the equivalent of the
 | |
|          64 bits counter acdRegulatorStatsDropHCPkts."
 | |
|     ::= { acdRegulatorStatsEntry 13 }
 | |
| 
 | |
| acdRegulatorStatsDropHCPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator."
 | |
|     ::= { acdRegulatorStatsEntry 14 }
 | |
| 
 | |
| acdRegulatorStatsDropRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The drop rate."
 | |
|     ::= { acdRegulatorStatsEntry 15 }
 | |
| 
 | |
| ---------------------------------------------------------------------------
 | |
|  -- The Regulator History group
 | |
| 
 | |
|  -- The Regulator History group records periodic statistical samples
 | |
|  -- from a regulator and stores them for later retrieval.
 | |
| 
 | |
| ---------------------------------------------------------------------------
 | |
| 
 | |
| acdRegulatorHistStatsTable OBJECT-TYPE
 | |
|     SYNTAX      SEQUENCE OF AcdRegulatorHistStatsEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|             "Table of all counters associated with each regulator."
 | |
|     ::= { acdRegulator 3 }
 | |
| 
 | |
| acdRegulatorHistStatsEntry OBJECT-TYPE
 | |
|     SYNTAX      AcdRegulatorHistStatsEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|             "An Entry consists of statitics related to a regulator entry."
 | |
|     INDEX   { acdRegulatorHistStatsID , acdRegulatorHistStatsSampleIndex }
 | |
|     ::=  { acdRegulatorHistStatsTable 1 }
 | |
| 
 | |
| 
 | |
| AcdRegulatorHistStatsEntry ::= SEQUENCE {
 | |
|     acdRegulatorHistStatsID                     Unsigned32,
 | |
|     acdRegulatorHistStatsSampleIndex            Unsigned32,
 | |
|     acdRegulatorHistStatsStatus                 INTEGER,
 | |
|     acdRegulatorHistStatsDuration               Unsigned32,
 | |
|     acdRegulatorHistStatsIntervalEnd            DateAndTime,
 | |
|     acdRegulatorHistStatsAcceptOctets           Counter32,
 | |
|     acdRegulatorHistStatsAcceptOverflowOctets   Counter32,
 | |
|     acdRegulatorHistStatsAcceptHCOctets         Counter64,
 | |
|     acdRegulatorHistStatsAcceptPkts             Counter32,
 | |
|     acdRegulatorHistStatsAcceptOverflowPkts     Counter32,
 | |
|     acdRegulatorHistStatsAcceptHCPkts           Counter64,
 | |
|     acdRegulatorHistStatsAcceptAvgRate          Gauge32,
 | |
|     acdRegulatorHistStatsAcceptMinRate          Gauge32,
 | |
|     acdRegulatorHistStatsAcceptMaxRate          Gauge32,
 | |
|     acdRegulatorHistStatsDropOctets             Counter32,
 | |
|     acdRegulatorHistStatsDropOverflowOctets     Counter32,
 | |
|     acdRegulatorHistStatsDropHCOctets           Counter64,
 | |
|     acdRegulatorHistStatsDropPkts               Counter32,
 | |
|     acdRegulatorHistStatsDropOverflowPkts       Counter32,
 | |
|     acdRegulatorHistStatsDropHCPkts             Counter64,
 | |
|     acdRegulatorHistStatsDropAvgRate            Gauge32,
 | |
|     acdRegulatorHistStatsDropMinRate            Gauge32,
 | |
|     acdRegulatorHistStatsDropMaxRate            Gauge32
 | |
| }
 | |
| 
 | |
| acdRegulatorHistStatsID  OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Unique value for each regulator entry. Its value ranges from 1 to
 | |
|         MAXINT (4 bytes)."
 | |
|     ::= { acdRegulatorHistStatsEntry 1 }
 | |
| 
 | |
| acdRegulatorHistStatsSampleIndex  OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "An index that uniquely identifies the particular sample this entry
 | |
|          represents among all samples associated with the same regulator
 | |
|          instance. This index starts at 1 and increases by one as each new
 | |
|          sample."
 | |
|     ::= { acdRegulatorHistStatsEntry 2 }
 | |
| 
 | |
| acdRegulatorHistStatsStatus OBJECT-TYPE
 | |
|     SYNTAX      INTEGER {
 | |
|                     valid(1),
 | |
|                     invalid(2)
 | |
|     }
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The status of this acdRegulatorHistStats entry."
 | |
|     ::= { acdRegulatorHistStatsEntry 3 }
 | |
| 
 | |
| acdRegulatorHistStatsDuration  OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The interval in seconds over which the data is sampled for this entry."
 | |
|     ::= { acdRegulatorHistStatsEntry 4 }
 | |
| 
 | |
| acdRegulatorHistStatsIntervalEnd OBJECT-TYPE
 | |
|     SYNTAX      DateAndTime
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "This is the time of the end of this entry."
 | |
|     ::= { acdRegulatorHistStatsEntry 5 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator during this
 | |
|          sampling interval. This is a 32 bits counter. Combined with
 | |
|          acdRegulatorHistStatsAcceptOverflowOctets, it provides the equivalent
 | |
|          of the 64 bits counter acdRegulatorHistStatsAcceptHCOctets."
 | |
|     ::= { acdRegulatorHistStatsEntry 6 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptOverflowOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorHistStatsAcceptOctets
 | |
|          counter has overflowed during this sampling interval. This is a
 | |
|          32 bits counter. Combined with acdRegulatorHistStatsAcceptOctets,
 | |
|          it provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorHistStatsAcceptHCOctets."
 | |
|     ::= { acdRegulatorHistStatsEntry 7 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptHCOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator during this
 | |
|          sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 8 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator during this
 | |
|          sampling interval. This is a 32 bits counter. Combined with
 | |
|          acdRegulatorHistStatsAcceptOverflowPkts, it provides the equivalent
 | |
|          of the 64 bits counter acdRegulatorHistStatsAcceptHCPkts."
 | |
|     ::= { acdRegulatorHistStatsEntry 9 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptOverflowPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorHistStatsAcceptPkts
 | |
|          counter has overflowed during this sampling interval. This is a
 | |
|          32 bits counter. Combined with acdRegulatorHistStatsAcceptPkts, it
 | |
|          provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorHistStatsAcceptHCPkts."
 | |
|     ::= { acdRegulatorHistStatsEntry 10 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptHCPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator during this
 | |
|          sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 11 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptAvgRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The average accept rate during this sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 12 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptMinRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The minimum accept rate during this sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 13 }
 | |
| 
 | |
| acdRegulatorHistStatsAcceptMaxRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The maximum accept rate during this sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 14 }
 | |
| 
 | |
| acdRegulatorHistStatsDropOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator during this
 | |
|          sampling interval. This is a 32 bits counter. Combined the overflow,
 | |
|          counter it provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorHistStatsDropHCOctets."
 | |
|     ::= { acdRegulatorHistStatsEntry 15 }
 | |
| 
 | |
| acdRegulatorHistStatsDropOverflowOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorHistStatsDropOctets
 | |
|          counter has overflowed during this sampling interval. This is a
 | |
|          32 bits counter. Combined with acdRegulatorHistStatsDropOctets, it
 | |
|          provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorHistStatsDropHCOctets."
 | |
|     ::= { acdRegulatorHistStatsEntry 16 }
 | |
| 
 | |
| acdRegulatorHistStatsDropHCOctets OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of octets received by this regulator during this
 | |
|          sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 17 }
 | |
| 
 | |
| acdRegulatorHistStatsDropPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator during this
 | |
|          sampling interval. This is a 32 bits counter. Combined with
 | |
|          acdRegulatorHistStatsDropOverflowPkts, it provides the equivalent of
 | |
|          the 64 bits counter acdRegulatorHistStatsDropHCPkts."
 | |
|     ::= { acdRegulatorHistStatsEntry 18 }
 | |
| 
 | |
| acdRegulatorHistStatsDropOverflowPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter32
 | |
|     UNITS       "Packets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of times the associated acdRegulatorHistStatsDropPkts
 | |
|          counter has overflowed during this sampling interval. This is a
 | |
|          32 bits counter. Combined with acdRegulatorHistStatsDropPkts, it
 | |
|          provides the equivalent of the 64 bits counter
 | |
|          acdRegulatorHistStatsDropHCPkts."
 | |
|     ::= { acdRegulatorHistStatsEntry 19 }
 | |
| 
 | |
| acdRegulatorHistStatsDropHCPkts OBJECT-TYPE
 | |
|     SYNTAX      Counter64
 | |
|     UNITS       "Octets"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The total number of packets received by this regulator during this
 | |
|          sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 20 }
 | |
| 
 | |
| acdRegulatorHistStatsDropAvgRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The average drop rate during this sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 21 }
 | |
| 
 | |
| acdRegulatorHistStatsDropMinRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The minimum drop rate during this sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 22 }
 | |
| 
 | |
| acdRegulatorHistStatsDropMaxRate OBJECT-TYPE
 | |
|     SYNTAX      Gauge32
 | |
|     UNITS       "Kbps"
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The maximum drop rate during this sampling interval."
 | |
|     ::= { acdRegulatorHistStatsEntry 23 }
 | |
| 
 | |
| ---------------------------------------------------------------------------
 | |
|  -- Transaction ID Information
 | |
| ---------------------------------------------------------------------------
 | |
| 
 | |
| acdRegulatorTableLastChangeTid OBJECT-TYPE
 | |
|     SYNTAX      Unsigned32
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "This is the transaction ID of the last change of the acdRegulatorTable
 | |
|         table.  If this value is different since the last read this is indicate 
 | |
|         a table change."
 | |
|     ::= { acdRegulatorTableTid 1 }
 | |
| 
 | |
| ---------------------------------------------------------------------------
 | |
|  -- ACD-REGULATOR-MIB Module - Conformance Information
 | |
| ---------------------------------------------------------------------------
 | |
| 
 | |
| acdRegulatorCompliances  OBJECT IDENTIFIER ::= { acdRegulatorConformance 1 }
 | |
| acdRegulatorGroups       OBJECT IDENTIFIER ::= { acdRegulatorConformance 2 }
 | |
| 
 | |
| ---------------------------------------------------------------------------
 | |
|  -- Units of conformance
 | |
| ---------------------------------------------------------------------------
 | |
| 
 | |
| acdRegulatorGroup OBJECT-GROUP
 | |
|     OBJECTS {
 | |
|         acdRegulatorName,
 | |
|         acdRegulatorCir,
 | |
|         acdRegulatorCbs,
 | |
|         acdRegulatorEir,
 | |
|         acdRegulatorEbs,
 | |
|         acdRegulatorIsBlind,
 | |
|         acdRegulatorIsCouple,
 | |
|         acdRegulatorRowStatus
 | |
|     }
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "Objects for the Regulator configurtion Group."
 | |
|     ::= { acdRegulatorGroups 1 }
 | |
| 
 | |
| acdRegulatorStatsGroup OBJECT-GROUP
 | |
|     OBJECTS {
 | |
|         acdRegulatorStatsAcceptOctets,
 | |
|         acdRegulatorStatsAcceptOverflowOctets,
 | |
|         acdRegulatorStatsAcceptHCOctets,
 | |
|         acdRegulatorStatsAcceptPkts,
 | |
|         acdRegulatorStatsAcceptOverflowPkts,
 | |
|         acdRegulatorStatsAcceptHCPkts,
 | |
|         acdRegulatorStatsAcceptRate,
 | |
|         acdRegulatorStatsDropOctets,
 | |
|         acdRegulatorStatsDropOverflowOctets,
 | |
|         acdRegulatorStatsDropHCOctets,
 | |
|         acdRegulatorStatsDropPkts,
 | |
|         acdRegulatorStatsDropOverflowPkts,
 | |
|         acdRegulatorStatsDropHCPkts,
 | |
|         acdRegulatorStatsDropRate
 | |
|     }
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "Objects for the Regulator statistics Group."
 | |
|     ::= { acdRegulatorGroups 2 }
 | |
| 
 | |
| acdRegulatorHistStatsGroup OBJECT-GROUP
 | |
|     OBJECTS {
 | |
|         acdRegulatorHistStatsStatus,
 | |
|         acdRegulatorHistStatsDuration,
 | |
|         acdRegulatorHistStatsIntervalEnd,
 | |
|         acdRegulatorHistStatsAcceptOctets,
 | |
|         acdRegulatorHistStatsAcceptOverflowOctets,
 | |
|         acdRegulatorHistStatsAcceptHCOctets,
 | |
|         acdRegulatorHistStatsAcceptPkts,
 | |
|         acdRegulatorHistStatsAcceptOverflowPkts,
 | |
|         acdRegulatorHistStatsAcceptHCPkts,
 | |
|         acdRegulatorHistStatsAcceptAvgRate,
 | |
|         acdRegulatorHistStatsAcceptMinRate,
 | |
|         acdRegulatorHistStatsAcceptMaxRate,
 | |
|         acdRegulatorHistStatsDropOctets,
 | |
|         acdRegulatorHistStatsDropOverflowOctets,
 | |
|         acdRegulatorHistStatsDropHCOctets,
 | |
|         acdRegulatorHistStatsDropPkts,
 | |
|         acdRegulatorHistStatsDropOverflowPkts,
 | |
|         acdRegulatorHistStatsDropHCPkts,
 | |
|         acdRegulatorHistStatsDropAvgRate,
 | |
|         acdRegulatorHistStatsDropMinRate,
 | |
|         acdRegulatorHistStatsDropMaxRate
 | |
|     }
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "Objects for the Regulator history statistics Group."
 | |
|     ::= { acdRegulatorGroups 3 }
 | |
| 
 | |
| acdRegulatorTidGroup OBJECT-GROUP
 | |
|     OBJECTS {
 | |
|         acdRegulatorTableLastChangeTid
 | |
|     }
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "List of scalars to monitior changes in tables."
 | |
|     ::= { acdRegulatorGroups 4 }
 | |
| 
 | |
| acdPaaCompliance MODULE-COMPLIANCE
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "The compliance statement for support of the ACD-REGULATOR-MIB module."
 | |
|     MODULE
 | |
|         MANDATORY-GROUPS {
 | |
|             acdRegulatorGroup,
 | |
|             acdRegulatorStatsGroup,
 | |
|             acdRegulatorHistStatsGroup,
 | |
|             acdRegulatorTidGroup
 | |
|          }
 | |
| 
 | |
|     OBJECT  acdRegulatorRowStatus
 | |
|       SYNTAX       RowStatus { active(1) }
 | |
|       WRITE-SYNTAX RowStatus { createAndGo(4), destroy(6) }
 | |
|       DESCRIPTION "Support for createAndWait is not required."
 | |
| 
 | |
|     ::= { acdRegulatorCompliances 1 }
 | |
| 
 | |
| 
 | |
| END
 | 