mibs/MIBS/adtran/ADTRAN-AOS-MUX-MIB

452 lines
14 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
ADTRAN-AOS-MUX-MIB DEFINITIONS ::= BEGIN
-- TITLE: THE ADTRAN OPERATING SYSTEM MULTIPLEXING MIB
-- FILENAME: AdGenAOSMux.mib
-- AUTHOR: Jason Schock
-- DATE: 10/15/04
-- HISTORY
-- 10/15/04 First draft.
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
RowStatus
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
adIdentity
FROM ADTRAN-MIB
adGenAOSCommon, adGenAOSConformance
FROM ADTRAN-AOS;
adGenAOSMuxID MODULE-IDENTITY
LAST-UPDATED "200410150000Z"
ORGANIZATION "ADTRAN, Inc."
CONTACT-INFO
"Technical Support Dept.
Postal: ADTRAN, Inc.
901 Explorer Blvd.
Huntsville, AL 35806
Tel: +1 800 726-8663
Fax: +1 256 963 6217
E-mail: support@adtran.com"
DESCRIPTION
"The MIB module for the management of AOS products with
TDM multiplexing and/or cross-connects."
::= { adIdentity 10000 53 1 5 }
-- OBJECT IDENTIFIERS
adGenAOSMux OBJECT IDENTIFIER ::= { adGenAOSCommon 5 }
adGenAOSXConnect OBJECT IDENTIFIER ::= { adGenAOSMux 1 }
adGenAOSTdmGroup OBJECT IDENTIFIER ::= { adGenAOSMux 2 }
adGenAOSMuxConformance OBJECT IDENTIFIER ::= { adGenAOSMux 99 }
adGenAOSMuxCompliance OBJECT IDENTIFIER ::= { adGenAOSMuxConformance 1 }
adGenAOSMuxMibGroups OBJECT IDENTIFIER ::= { adGenAOSMuxConformance 2 }
--
-- XConnect Configuration Table
--
adGenAOSXConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenAOSXConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Cross-Connect Configuration Table"
::= { adGenAOSXConnect 1 }
adGenAOSXConnectEntry OBJECT-TYPE
SYNTAX AdGenAOSXConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Cross-Connect Configuration Table"
INDEX{ adGenAOSXConnectIndex }
::= { adGenAOSXConnectTable 1 }
AdGenAOSXConnectEntry ::= SEQUENCE
{
adGenAOSXConnectIndex INTEGER,
adGenAOSXConnectFirstIfType INTEGER,
adGenAOSXConnectFirstIfNumber INTEGER,
adGenAOSXConnectFirstSubIfNumber INTEGER,
adGenAOSXConnectFirstIfSlot INTEGER,
adGenAOSXConnectFirstIfPort INTEGER,
adGenAOSXConnectFirstTdmGroup INTEGER,
adGenAOSXConnectFirstTdmGroupDS0 INTEGER,
adGenAOSXConnectSecondIfType INTEGER,
adGenAOSXConnectSecondIfNumber INTEGER,
adGenAOSXConnectSecondSubIfNumber INTEGER,
adGenAOSXConnectSecondIfSlot INTEGER,
adGenAOSXConnectSecondIfPort INTEGER,
adGenAOSXConnectSecondTdmGroup INTEGER,
adGenAOSXConnectSecondTdmGroupDS0 INTEGER,
adGenAOSXConnectPreserveRbs INTEGER,
adGenAOSXConnectRowStatus RowStatus
}
adGenAOSXConnectIndex OBJECT-TYPE
SYNTAX INTEGER (1..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number that uniquely defines the cross-connect"
::= { adGenAOSXConnectEntry 1 }
adGenAOSXConnectFirstIfType OBJECT-TYPE
SYNTAX INTEGER
{
notAssigned(0),
dds(1), -- from only
t1E1(2), -- from/to
eth(3), -- from only
serial(4), -- from/to
shdsl(5), -- from only
fxs(6), -- to only
frameRelay(7), -- from/to
ppp(8) -- to only
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of interface from which a cross-connect is being
made"
::= { adGenAOSXConnectEntry 2 }
adGenAOSXConnectFirstIfNumber OBJECT-TYPE
SYNTAX INTEGER (0..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number that defines the interface described by
adGenAOSXConnectFirstIfType -- set to 0 if the interface
can be defined by adGenAOSXConnectFirstIfSlot and
adGenAOSXConnectFirstIfPort"
::= { adGenAOSXConnectEntry 3 }
adGenAOSXConnectFirstSubIfNumber OBJECT-TYPE
SYNTAX INTEGER (0..1007)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number that further defines some interfaces -- set to
0 if the interface can be defined by adGenAOSXConnectFirstIfSlot
and adGenAOSXConnectFirstIfPort"
::= { adGenAOSXConnectEntry 4 }
adGenAOSXConnectFirstIfSlot OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The slot number containing the interface described by
adGenAOSXConnectFirstIfType -- set to 0 if the interface
can be defined by adGenAOSXConnectFirstIfNumber (and
adGenAOSXConnectFirstSubIfNumber)
Note: 0 is also a valid slot number."
::= { adGenAOSXConnectEntry 5 }
adGenAOSXConnectFirstIfPort OBJECT-TYPE
SYNTAX INTEGER (0..48)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The port number of the interface described by
adGenAOSXConnectFirstIfType -- set to 0 if the interface
can be defined by adGenAOSXConnectFirstIfNumber (and
adGenAOSXConnectFirstSubIfNumber)"
::= { adGenAOSXConnectEntry 6 }
adGenAOSXConnectFirstTdmGroup OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number uniquely identifying the TDM Group associated
with the interface described by adGenAOSXConnectFirstIfType
-- set to 0 if it is not necessary that a TDM Group be
associated with the interface"
::= { adGenAOSXConnectEntry 7 }
adGenAOSXConnectFirstTdmGroupDS0 OBJECT-TYPE
SYNTAX INTEGER (0..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The specific DS0 of the TDM Group, described by
adGenAOSXConnectFirstTdmGroup, from which a cross-
connect is being made -- set to 0 if it is not necessary
that a specific timeslot be defined"
::= { adGenAOSXConnectEntry 8 }
adGenAOSXConnectSecondIfType OBJECT-TYPE
SYNTAX INTEGER
{
notAssigned(0),
dds(1), -- from only
t1E1(2), -- from/to
eth(3), -- from only
serial(4), -- from/to
shdsl(5), -- from only
fxs(6), -- to only
frameRelay(7), -- from/to
ppp(8) -- to only
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of interface to which a cross-connect is being
made"
::= { adGenAOSXConnectEntry 9 }
adGenAOSXConnectSecondIfNumber OBJECT-TYPE
SYNTAX INTEGER (0..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number that defines the interface described by
adGenAOSXConnectSecondIfType -- set to 0 if the interface
can be defined by adGenAOSXConnectSecondIfSlot and
adGenAOSXConnectSecondIfPort"
::= { adGenAOSXConnectEntry 10 }
adGenAOSXConnectSecondSubIfNumber OBJECT-TYPE
SYNTAX INTEGER (0..1007)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number that further defines some interfaces -- set to
0 if the interface can be defined by adGenAOSXConnectSecondIfSlot
and adGenAOSXConnectSecondIfPort"
::= { adGenAOSXConnectEntry 11 }
adGenAOSXConnectSecondIfSlot OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The slot number containing the interface described by
adGenAOSXConnectSecondIfType -- set to 0 if the interface
can be defined by adGenAOSXConnectSecondIfNumber (and
adGenAOSXConnectSecondSubIfNumber)
Note: 0 is also a valid slot number."
::= { adGenAOSXConnectEntry 12 }
adGenAOSXConnectSecondIfPort OBJECT-TYPE
SYNTAX INTEGER (0..48)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The port number of the interface described by
adGenAOSXConnectSecondIfType -- set to 0 if the interface
can be defined by adGenAOSXConnectSecondIfNumber (and
adGenAOSXConnectSecondSubIfNumber)"
::= { adGenAOSXConnectEntry 13 }
adGenAOSXConnectSecondTdmGroup OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number uniquely identifying the TDM Group associated
with the interface described by adGenAOSXConnectSecondIfType
-- set to 0 if it is not necessary that a TDM Group be
associated with the interface"
::= { adGenAOSXConnectEntry 14 }
adGenAOSXConnectSecondTdmGroupDS0 OBJECT-TYPE
SYNTAX INTEGER (0..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The specific DS0 of the TDM Group, described by
adGenAOSXConnectSecondTdmGroup, to which a cross-
connect is being made -- set to 0 if it is not necessary
that a specific timeslot be defined"
::= { adGenAOSXConnectEntry 15 }
adGenAOSXConnectPreserveRbs OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ability of the cross-connect to maintain robbed-bit
signaling integrity -- set to disabled if robbed-bit
signaling is not a characteristic of the cross-connect."
::= { adGenAOSXConnectEntry 16 }
adGenAOSXConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this conceptual row. Until instances
of appropriate corresponding columns are configured,
the value of the corresponding instance of the
adGenAOSXConnectStatus column is 'notReady'."
::= { adGenAOSXConnectEntry 17 }
--
-- TDM Group Configuration Table
--
adGenAOSTdmGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdGenAOSTdmGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The TDM Group Table that associates DS0s into mappable
units"
::= { adGenAOSTdmGroup 1 }
adGenAOSTdmGroupEntry OBJECT-TYPE
SYNTAX AdGenAOSTdmGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the TDM Group Table"
INDEX{ adGenAOSTdmGroupIfSlot, adGenAOSTdmGroupIfPort, adGenAOSTdmGroupID }
::= { adGenAOSTdmGroupTable 1 }
AdGenAOSTdmGroupEntry ::= SEQUENCE
{
adGenAOSTdmGroupIfSlot INTEGER,
adGenAOSTdmGroupIfPort INTEGER,
adGenAOSTdmGroupID INTEGER,
adGenAOSTdmGroupMask INTEGER,
adGenAOSTdmGroupUsage INTEGER
}
adGenAOSTdmGroupIfSlot OBJECT-TYPE
SYNTAX INTEGER (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number containing the interface for
the TDM Group"
::= { adGenAOSTdmGroupEntry 1 }
adGenAOSTdmGroupIfPort OBJECT-TYPE
SYNTAX INTEGER (0..48)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number containing the interface for
the TDM Group"
::= { adGenAOSTdmGroupEntry 2 }
adGenAOSTdmGroupID OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number that uniquely defines the TDM Group"
::= { adGenAOSTdmGroupEntry 3 }
adGenAOSTdmGroupMask OBJECT-TYPE
SYNTAX INTEGER (-2147483648..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A bitmap of the contiguous DS0s included in this TDM Group
Example: mapping DS0s 1-12:
00000000000000000000111111111111 (bin),
00000FFF (hex),
4095 (dec)
Note: To create a new row in adGenAOSTdmGroupTable,
set adGenAOSTdmGroupMask with the appropriate
index values corresponding to the desired slot,
port, and TDM group ID"
::= { adGenAOSTdmGroupEntry 4 }
adGenAOSTdmGroupUsage OBJECT-TYPE
SYNTAX INTEGER
{
fiftySixKbps(1),
sixtyFourKbps(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The speed of the individual DS0s"
::= { adGenAOSTdmGroupEntry 5 }
--
-- Compliance Statements
--
adGenAOSMuxConformancemModule MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMPv2 entities which
implement the adGenAOSMux MIB."
MODULE
MANDATORY-GROUPS
{
adGenAOSXConnectGrp,
adGenAOSTdmGroupGrp
}
::= { adGenAOSMuxCompliance 1 }
-- units of conformance
adGenAOSXConnectGrp OBJECT-GROUP
OBJECTS
{
adGenAOSXConnectIndex,
adGenAOSXConnectFirstIfType,
adGenAOSXConnectFirstIfNumber,
adGenAOSXConnectFirstSubIfNumber,
adGenAOSXConnectFirstIfSlot,
adGenAOSXConnectFirstIfPort,
adGenAOSXConnectFirstTdmGroup,
adGenAOSXConnectFirstTdmGroupDS0,
adGenAOSXConnectSecondIfType,
adGenAOSXConnectSecondIfNumber,
adGenAOSXConnectSecondSubIfNumber,
adGenAOSXConnectSecondIfSlot,
adGenAOSXConnectSecondIfPort,
adGenAOSXConnectSecondTdmGroup,
adGenAOSXConnectSecondTdmGroupDS0,
adGenAOSXConnectPreserveRbs,
adGenAOSXConnectRowStatus
}
STATUS current
DESCRIPTION
"The Cross-Connect Group."
::= { adGenAOSMuxMibGroups 1 }
adGenAOSTdmGroupGrp OBJECT-GROUP
OBJECTS
{
adGenAOSTdmGroupIfSlot,
adGenAOSTdmGroupIfPort,
adGenAOSTdmGroupID,
adGenAOSTdmGroupMask,
adGenAOSTdmGroupUsage
}
STATUS current
DESCRIPTION
"The TDM Group Group."
::= { adGenAOSMuxMibGroups 2 }
END