812 lines
24 KiB
Plaintext
812 lines
24 KiB
Plaintext
|
--- ****************************************************************************
|
||
|
-- *
|
||
|
-- * Description: Implements definitions for the BK-Ethernet-Switch-modules
|
||
|
-- *
|
||
|
-- * Copyright 2007 by BKtel communications GmbH
|
||
|
-- *
|
||
|
-- *
|
||
|
-- * V.0.1 12.05.2006 M. Heldmann first draft
|
||
|
-- * V.0.2 04.10.2006 M. Heldmann NESlotWriteValue expanded due to new 2G6 platform needs
|
||
|
-- * V.1.0 11.05.2007 M. Heldmann renamed this module from "bkswitch" to "bkbes"
|
||
|
-- * added a couple of parameters
|
||
|
-- * V.1.1 11.07.2013 M. Heldmann adjusted syntax of "CommonEntry" to remove MIB compiler warnings
|
||
|
-- * V.1.2 05.09.2014 M. Heldmann changed CommonModuleWidth and ConfigNESlotWrite STATUS to optional
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
BKTEL-HFC862-BES-V01-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
experimental, enterprises, TimeTicks, IpAddress, Counter
|
||
|
FROM RFC1155-SMI
|
||
|
OBJECT-TYPE
|
||
|
FROM RFC-1212
|
||
|
TRAP-TYPE
|
||
|
FROM RFC-1215
|
||
|
modules, DisplayString, TruthValue, PerceivedSeverityValue, NESlotValue, ModuleWidthValue
|
||
|
FROM BKTEL-HFC862-BASE-MIB
|
||
|
;
|
||
|
|
||
|
bes OBJECT IDENTIFIER ::= { modules 114 }
|
||
|
besCommon OBJECT IDENTIFIER ::= { bes 1 }
|
||
|
besStates OBJECT IDENTIFIER ::= { bes 2 }
|
||
|
besConfiguration OBJECT IDENTIFIER ::= { bes 3 }
|
||
|
besControl OBJECT IDENTIFIER ::= { bes 4 }
|
||
|
besMeasuringValues OBJECT IDENTIFIER ::= { bes 5 }
|
||
|
besDisplay OBJECT IDENTIFIER ::= { bes 6 }
|
||
|
besDisplayPorts OBJECT IDENTIFIER ::= { bes 56 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- Type definitions
|
||
|
--
|
||
|
|
||
|
PortType ::= INTEGER
|
||
|
{
|
||
|
typeCopper(1),
|
||
|
typeFiber(2)
|
||
|
}
|
||
|
|
||
|
PortLinkState ::= INTEGER
|
||
|
{
|
||
|
linkDown(1),
|
||
|
linkUp(2)
|
||
|
}
|
||
|
|
||
|
PortStatus ::= INTEGER
|
||
|
{
|
||
|
statusUnknown(1),
|
||
|
statusInit(2),
|
||
|
statusValid(3),
|
||
|
statusBusy(4),
|
||
|
statusEmpty(5),
|
||
|
statusInvalid(6),
|
||
|
statusLossOfSignal(7)
|
||
|
}
|
||
|
|
||
|
PortDuplexMode ::= INTEGER
|
||
|
{
|
||
|
duplexFull(1),
|
||
|
duplexHalf(2)
|
||
|
}
|
||
|
|
||
|
PortSpeed ::= INTEGER
|
||
|
{
|
||
|
speedUnknown(0),
|
||
|
speed10Mbps(10),
|
||
|
speed100Mbps(100),
|
||
|
speed1000Mbps(1000)
|
||
|
}
|
||
|
|
||
|
PortFlowControl ::= INTEGER
|
||
|
{
|
||
|
flowControlDisabled(1),
|
||
|
flowControlEnabled(2)
|
||
|
}
|
||
|
|
||
|
NESlotWriteValue ::= INTEGER (-1..99)
|
||
|
|
||
|
|
||
|
-- MibCompiler defs --
|
||
|
-- $idx$: besDisplayConfiguration
|
||
|
-- MibCompiler defs --
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
-- BES (BK Ethernet Switch)
|
||
|
--*****************************************************************************************
|
||
|
-- besCommon group
|
||
|
|
||
|
besCommonNumberOfModules OBJECT-TYPE
|
||
|
SYNTAX INTEGER(0..50)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Number of modules in table."
|
||
|
::= { besCommon 1 }
|
||
|
|
||
|
besCommonTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BesCommonEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The table contains all modules of the BES-type in the NE"
|
||
|
::= { besCommon 2 }
|
||
|
|
||
|
-- table of states entry(ro/rw)
|
||
|
|
||
|
besCommonEntry OBJECT-TYPE
|
||
|
SYNTAX BesCommonEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Common-Values for a module."
|
||
|
INDEX { besNESlot }
|
||
|
::= { besCommonTable 1 }
|
||
|
|
||
|
-- the structure of the entry
|
||
|
|
||
|
BesCommonEntry ::= SEQUENCE
|
||
|
{
|
||
|
besNESlot NESlotValue,
|
||
|
besCommonType DisplayString,
|
||
|
besCommonDescr DisplayString,
|
||
|
besCommonFirmwareId DisplayString,
|
||
|
besCommonModuleWidth ModuleWidthValue
|
||
|
}
|
||
|
|
||
|
besNESlot OBJECT-TYPE
|
||
|
SYNTAX NESlotValue
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot number of the chassis for which this
|
||
|
entry contains management information."
|
||
|
::= { besCommonEntry 1 }
|
||
|
|
||
|
besCommonType OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The type of physical module. modSlotEmpty indicates
|
||
|
an empty slot. A Value of modSlotUnknown indicates
|
||
|
that the type of module is unknown."
|
||
|
::= { besCommonEntry 2 }
|
||
|
|
||
|
besCommonDescr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A textual description of the module.
|
||
|
If not available, this Value should be
|
||
|
set to a zero length string."
|
||
|
::= { besCommonEntry 3 }
|
||
|
|
||
|
besCommonFirmwareId OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE(0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The firmware Id of the module."
|
||
|
::= { besCommonEntry 4 }
|
||
|
|
||
|
besCommonModuleWidth OBJECT-TYPE
|
||
|
SYNTAX ModuleWidthValue
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION "The width of the module in multiples of slots (1, 2, ...)"
|
||
|
::= { besCommonEntry 5 }
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
-- besMeasuringValues group
|
||
|
|
||
|
-- table of measuring Values
|
||
|
|
||
|
besMeasuringValuesTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BesMeasuringValuesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
::= { besMeasuringValues 1 }
|
||
|
|
||
|
-- table of measuring Values entry
|
||
|
|
||
|
besMeasuringValuesEntry OBJECT-TYPE
|
||
|
SYNTAX BesMeasuringValuesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Common-Values for a module."
|
||
|
INDEX { besNESlot }
|
||
|
::= { besMeasuringValuesTable 1 }
|
||
|
|
||
|
-- the structure of the entry
|
||
|
|
||
|
BesMeasuringValuesEntry ::= SEQUENCE
|
||
|
{
|
||
|
besTemperatureLoLo INTEGER,
|
||
|
besTemperatureLo INTEGER,
|
||
|
besTemperatureValue INTEGER,
|
||
|
besTemperatureHi INTEGER,
|
||
|
besTemperatureHiHi INTEGER,
|
||
|
|
||
|
besInputVoltageLoLo INTEGER,
|
||
|
besInputVoltageLo INTEGER,
|
||
|
besInputVoltageValue INTEGER,
|
||
|
besInputVoltageHi INTEGER,
|
||
|
besInputVoltageHiHi INTEGER
|
||
|
}
|
||
|
|
||
|
-- *****
|
||
|
besTemperatureLoLo OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Device temperature low alarm threshold in 0.1 celsius degrees."
|
||
|
::= { besMeasuringValuesEntry 1 }
|
||
|
|
||
|
besTemperatureLo OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Device temperature low warning threshold in 0.1 celsius degrees."
|
||
|
::= { besMeasuringValuesEntry 2 }
|
||
|
|
||
|
besTemperatureValue OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Device temperature in 0.1 celsius degrees."
|
||
|
::= { besMeasuringValuesEntry 3 }
|
||
|
|
||
|
besTemperatureHi OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Device temperature high warning threshold in 0.1 celsius degrees."
|
||
|
::= { besMeasuringValuesEntry 4 }
|
||
|
|
||
|
besTemperatureHiHi OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Device temperature high alarm threshold in 0.1 celsius degrees."
|
||
|
::= { besMeasuringValuesEntry 5 }
|
||
|
|
||
|
-- *****
|
||
|
besInputVoltageLoLo OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The input supply voltage low alarm threshold in steps of 0.1 Volts."
|
||
|
::= { besMeasuringValuesEntry 6 }
|
||
|
|
||
|
besInputVoltageLo OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The input supply voltage low warning threshold in steps of 0.1 Volts."
|
||
|
::= { besMeasuringValuesEntry 7 }
|
||
|
|
||
|
besInputVoltageValue OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The input supply voltage in steps of 0.1 Volts.
|
||
|
Input supply voltage nominal value, see 'besDisplayInputVoltageNominal'"
|
||
|
::= { besMeasuringValuesEntry 8 }
|
||
|
|
||
|
besInputVoltageHi OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The input supply voltage high warning threshold in steps of 0.1 Volts."
|
||
|
::= { besMeasuringValuesEntry 9 }
|
||
|
|
||
|
besInputVoltageHiHi OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The input supply voltage high alarm threshold in steps of 0.1 Volts."
|
||
|
::= { besMeasuringValuesEntry 10 }
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
-- besStates group
|
||
|
|
||
|
-- Note: For every control OId there must be a correspondant alarm OId!
|
||
|
|
||
|
besStatesTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BesStatesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
::= { besStates 1 }
|
||
|
|
||
|
-- table of states entry(ro/rw)
|
||
|
|
||
|
besStatesEntry OBJECT-TYPE
|
||
|
SYNTAX BesStatesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Alarms for a module."
|
||
|
INDEX { besNESlot }
|
||
|
::= { besStatesTable 1 }
|
||
|
|
||
|
-- the structure of the entry
|
||
|
|
||
|
BesStatesEntry ::= SEQUENCE
|
||
|
{
|
||
|
besStatesBootloader PerceivedSeverityValue,
|
||
|
besStatesCommLoss PerceivedSeverityValue,
|
||
|
besStatesTemperatureLow PerceivedSeverityValue,
|
||
|
besStatesTemperatureHigh PerceivedSeverityValue,
|
||
|
besStatesInputVoltageLow PerceivedSeverityValue,
|
||
|
besStatesInputVoltageHigh PerceivedSeverityValue
|
||
|
}
|
||
|
|
||
|
besStatesBootloader OBJECT-TYPE
|
||
|
SYNTAX PerceivedSeverityValue
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The device is running in bootloader mode
|
||
|
without a legal application software."
|
||
|
::= { besStatesEntry 1 }
|
||
|
|
||
|
besStatesCommLoss OBJECT-TYPE
|
||
|
SYNTAX PerceivedSeverityValue
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The NEC has lost the connection to the device.
|
||
|
Reason may be a removed or defective device.
|
||
|
Note that this state is set by the NEC and not
|
||
|
by the device"
|
||
|
::= { besStatesEntry 2 }
|
||
|
|
||
|
besStatesTemperatureLow OBJECT-TYPE
|
||
|
SYNTAX PerceivedSeverityValue
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Device temperature low"
|
||
|
::= { besStatesEntry 3 }
|
||
|
|
||
|
besStatesTemperatureHigh OBJECT-TYPE
|
||
|
SYNTAX PerceivedSeverityValue
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Device temperature high"
|
||
|
::= { besStatesEntry 4 }
|
||
|
|
||
|
besStatesInputVoltageLow OBJECT-TYPE
|
||
|
SYNTAX PerceivedSeverityValue
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Input supply voltage low"
|
||
|
::= { besStatesEntry 5 }
|
||
|
|
||
|
besStatesInputVoltageHigh OBJECT-TYPE
|
||
|
SYNTAX PerceivedSeverityValue
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Input supply voltage high"
|
||
|
::= { besStatesEntry 6 }
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
-- besControl group
|
||
|
|
||
|
besControlTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BesControlEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
::= { besControl 1 }
|
||
|
|
||
|
-- table of control entry(ro/rw)
|
||
|
|
||
|
besControlEntry OBJECT-TYPE
|
||
|
SYNTAX BesControlEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Alarms for a module."
|
||
|
INDEX { besNESlot }
|
||
|
::= { besControlTable 1 }
|
||
|
|
||
|
-- the structure of the entry
|
||
|
|
||
|
BesControlEntry ::= SEQUENCE
|
||
|
{
|
||
|
besControlReset TruthValue,
|
||
|
besControlModuleLedBlink TruthValue
|
||
|
}
|
||
|
|
||
|
besControlReset OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Reset the module."
|
||
|
::= { besControlEntry 1 }
|
||
|
|
||
|
besControlModuleLedBlink OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Writing this variable to true(1) lets the device's
|
||
|
modul LED blink green for 10 seconds.
|
||
|
Writing this variable to false(2) stbes blinking at once.
|
||
|
This variable always returns false(2) on read requests"
|
||
|
::= { besControlEntry 2 }
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
-- besConfiguration group
|
||
|
|
||
|
besConfigurationTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BesConfigurationEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
::= { besConfiguration 1 }
|
||
|
|
||
|
-- table of configuration entry(ro/rw)
|
||
|
|
||
|
besConfigurationEntry OBJECT-TYPE
|
||
|
SYNTAX BesConfigurationEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
INDEX { besNESlot }
|
||
|
::= { besConfigurationTable 1 }
|
||
|
|
||
|
-- the structure of the entry
|
||
|
|
||
|
BesConfigurationEntry ::= SEQUENCE
|
||
|
{
|
||
|
besConfigNESlotWrite NESlotWriteValue,
|
||
|
besConfigConfigurationIndex INTEGER,
|
||
|
besConfigConfiguration DisplayString
|
||
|
}
|
||
|
|
||
|
-- Common part
|
||
|
|
||
|
besConfigNESlotWrite OBJECT-TYPE
|
||
|
SYNTAX NESlotWriteValue
|
||
|
ACCESS read-write
|
||
|
STATUS optional
|
||
|
DESCRIPTION "By writing this variable a slot can be assigned
|
||
|
for devices that dont support hardware slot detection.
|
||
|
Reading '-1' means that the slot position is NOT writable."
|
||
|
::= { besConfigurationEntry 1 }
|
||
|
|
||
|
besConfigConfigurationIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Index of the active configuration (1..besDisplayNumberOfConfigs)"
|
||
|
::= { besConfigurationEntry 2 }
|
||
|
|
||
|
besConfigConfiguration OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of the active configuration"
|
||
|
::= { besConfigurationEntry 3 }
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
-- Display group
|
||
|
|
||
|
besDisplayTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BesDisplayEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
::= { besDisplay 1 }
|
||
|
|
||
|
-- table of configuration entry(ro/rw)
|
||
|
|
||
|
besDisplayEntry OBJECT-TYPE
|
||
|
SYNTAX BesDisplayEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
INDEX { besNESlot }
|
||
|
::= { besDisplayTable 1 }
|
||
|
|
||
|
-- the structure of the entry
|
||
|
|
||
|
BesDisplayEntry ::= SEQUENCE
|
||
|
{
|
||
|
besDisplayNumberOfPorts INTEGER,
|
||
|
besDisplayInputVoltageNominal INTEGER,
|
||
|
|
||
|
besDisplayNumberOfConfigs INTEGER,
|
||
|
besDisplayConfiguration1 DisplayString,
|
||
|
besDisplayConfiguration2 DisplayString,
|
||
|
besDisplayConfiguration3 DisplayString,
|
||
|
besDisplayConfiguration4 DisplayString,
|
||
|
besDisplayConfiguration5 DisplayString,
|
||
|
besDisplayConfiguration6 DisplayString,
|
||
|
besDisplayConfiguration7 DisplayString,
|
||
|
besDisplayConfiguration8 DisplayString,
|
||
|
besDisplayConfiguration9 DisplayString,
|
||
|
besDisplayConfiguration10 DisplayString,
|
||
|
besDisplayConfiguration11 DisplayString,
|
||
|
besDisplayConfiguration12 DisplayString,
|
||
|
besDisplayConfiguration13 DisplayString,
|
||
|
besDisplayConfiguration14 DisplayString,
|
||
|
besDisplayConfiguration15 DisplayString,
|
||
|
besDisplayConfiguration16 DisplayString
|
||
|
|
||
|
}
|
||
|
|
||
|
besDisplayNumberOfPorts OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of ports"
|
||
|
::={ besDisplayEntry 1 }
|
||
|
|
||
|
besDisplayInputVoltageNominal OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The nominal value of input voltage in 0.1 V units."
|
||
|
::={ besDisplayEntry 2 }
|
||
|
|
||
|
besDisplayNumberOfConfigs OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of different configurations supplied"
|
||
|
::={ besDisplayEntry 3 }
|
||
|
|
||
|
besDisplayConfiguration1 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #1"
|
||
|
::= { besDisplayEntry 4 }
|
||
|
|
||
|
besDisplayConfiguration2 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #2"
|
||
|
::= { besDisplayEntry 5 }
|
||
|
|
||
|
besDisplayConfiguration3 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #3"
|
||
|
::= { besDisplayEntry 6 }
|
||
|
|
||
|
besDisplayConfiguration4 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #4"
|
||
|
::= { besDisplayEntry 7 }
|
||
|
|
||
|
besDisplayConfiguration5 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #5"
|
||
|
::= { besDisplayEntry 8 }
|
||
|
|
||
|
besDisplayConfiguration6 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #6"
|
||
|
::= { besDisplayEntry 9 }
|
||
|
|
||
|
besDisplayConfiguration7 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #7"
|
||
|
::= { besDisplayEntry 10 }
|
||
|
|
||
|
besDisplayConfiguration8 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #8"
|
||
|
::= { besDisplayEntry 11 }
|
||
|
|
||
|
besDisplayConfiguration9 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #9"
|
||
|
::= { besDisplayEntry 12 }
|
||
|
|
||
|
besDisplayConfiguration10 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #10"
|
||
|
::= { besDisplayEntry 13 }
|
||
|
|
||
|
besDisplayConfiguration11 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #11"
|
||
|
::= { besDisplayEntry 14 }
|
||
|
|
||
|
besDisplayConfiguration12 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #12"
|
||
|
::= { besDisplayEntry 15 }
|
||
|
|
||
|
besDisplayConfiguration13 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #13"
|
||
|
::= { besDisplayEntry 16 }
|
||
|
|
||
|
besDisplayConfiguration14 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #14"
|
||
|
::= { besDisplayEntry 17 }
|
||
|
|
||
|
besDisplayConfiguration15 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #15"
|
||
|
::= { besDisplayEntry 18 }
|
||
|
|
||
|
besDisplayConfiguration16 OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of configuration no. #16"
|
||
|
::= { besDisplayEntry 19 }
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
-- DisplayPorts group
|
||
|
|
||
|
-- MibCompiler defs --
|
||
|
-- $suboids$: 56,1
|
||
|
-- MibCompiler defs --
|
||
|
|
||
|
besDisplayPortsTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BesDisplayPortsEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
::= { besDisplayPorts 1 }
|
||
|
|
||
|
-- table of configuration entry(ro/rw)
|
||
|
|
||
|
besDisplayPortsEntry OBJECT-TYPE
|
||
|
SYNTAX BesDisplayPortsEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION ""
|
||
|
INDEX { besNESlot, besDisplayPortsPortIndex }
|
||
|
::= { besDisplayPortsTable 1 }
|
||
|
|
||
|
-- the structure of the entry
|
||
|
|
||
|
BesDisplayPortsEntry ::= SEQUENCE
|
||
|
{
|
||
|
besDisplayPortsPortIndex INTEGER,
|
||
|
besDisplayPortsPortName DisplayString,
|
||
|
besDisplayPortsType PortType,
|
||
|
besDisplayPortsLinkState PortLinkState,
|
||
|
besDisplayPortsStatus PortStatus,
|
||
|
besDisplayPortsDuplexMode PortDuplexMode,
|
||
|
besDisplayPortsSpeed PortSpeed,
|
||
|
besDisplayPortsFlowControl PortFlowControl,
|
||
|
besDisplayPortsFiberTxDistance INTEGER,
|
||
|
besDisplayPortsFiberTxWavelen INTEGER,
|
||
|
besDisplayPortsFiberRxWavelenMin INTEGER,
|
||
|
besDisplayPortsFiberRxWavelenMax INTEGER,
|
||
|
besDisplayPortsFiberSfpData DisplayString
|
||
|
|
||
|
}
|
||
|
|
||
|
besDisplayPortsPortIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port index (1..besDisplayNumberOfPorts)"
|
||
|
::={ besDisplayPortsEntry 1 }
|
||
|
|
||
|
besDisplayPortsPortName OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port name"
|
||
|
::={ besDisplayPortsEntry 2 }
|
||
|
|
||
|
besDisplayPortsType OBJECT-TYPE
|
||
|
SYNTAX PortType
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port type"
|
||
|
::={ besDisplayPortsEntry 3 }
|
||
|
|
||
|
besDisplayPortsLinkState OBJECT-TYPE
|
||
|
SYNTAX PortLinkState
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port link status"
|
||
|
::={ besDisplayPortsEntry 4 }
|
||
|
|
||
|
besDisplayPortsStatus OBJECT-TYPE
|
||
|
SYNTAX PortStatus
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port status"
|
||
|
::={ besDisplayPortsEntry 5 }
|
||
|
|
||
|
besDisplayPortsDuplexMode OBJECT-TYPE
|
||
|
SYNTAX PortDuplexMode
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port duplex mode"
|
||
|
::={ besDisplayPortsEntry 6 }
|
||
|
|
||
|
besDisplayPortsSpeed OBJECT-TYPE
|
||
|
SYNTAX PortSpeed
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port speed"
|
||
|
::={ besDisplayPortsEntry 7 }
|
||
|
|
||
|
besDisplayPortsFlowControl OBJECT-TYPE
|
||
|
SYNTAX PortFlowControl
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port speed"
|
||
|
::={ besDisplayPortsEntry 8 }
|
||
|
|
||
|
besDisplayPortsFiberTxDistance OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port transmission distance in units of km (Fiber ports only)"
|
||
|
::={ besDisplayPortsEntry 9 }
|
||
|
|
||
|
besDisplayPortsFiberTxWavelen OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port transmission wavelength in units of nm (Fiber ports only)"
|
||
|
::={ besDisplayPortsEntry 10 }
|
||
|
|
||
|
besDisplayPortsFiberRxWavelenMin OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port minimum receive wavelength in units of nm (Fiber ports only)"
|
||
|
::={ besDisplayPortsEntry 11 }
|
||
|
|
||
|
besDisplayPortsFiberRxWavelenMax OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port maximum receive wavelength in units of nm (Fiber ports only)"
|
||
|
::={ besDisplayPortsEntry 12 }
|
||
|
|
||
|
besDisplayPortsFiberSfpData OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Port SFP data text (Fiber ports only)"
|
||
|
::={ besDisplayPortsEntry 13 }
|
||
|
|
||
|
|
||
|
|
||
|
--*****************************************************************************************
|
||
|
END
|
||
|
|