mibs/MIBS/bktel/BKTEL-HFC862-HMSNE-MIB

494 lines
15 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- ******************************************************************************************
-- *
-- * Description: Implements definitions for a HMS based network element
-- *
-- * Copyright 2014 by BKtel communications GmbH
-- *
-- * V.1.0 04.10.2006 M. Heldmann - created this "bkhmsne.mib" file based on BKtel systems "ahmsne.mib" file
-- * - marked all parameters that are not used by NMS implementation of BKtel communications GmbH
-- * - removed the 'ne' OID definition here and added 'ne' to IMPORTS
-- * because the 'ne' is defined in root mib too
-- * V.1.1 12.05.2014 M. Heldmann - marked all obsolete parameters as 'obsolete' - they may be no more supported by future NEC types and NEC software versions
-- * - expanded neModulTable by full inventory information
-- * - a couple of renamings
-- * - changed name neModulType to neModuleModelName with SYNTAX DisplayString
-- ******************************************************************************************
BKTEL-HFC862-HMSNE-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
ne, DisplayString, TruthValue, NESlotValue, PerceivedSeverityValue
FROM BKTEL-HFC862-BASE-MIB
;
neCommon OBJECT IDENTIFIER ::= { ne 1 }
neType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of NE"
::= { neCommon 1 }
neDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The description of the NE."
::= { neCommon 2 }
neLocationStreet OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Location Street of Network Element.
Writable size depends on net element controller, default 32"
::= { neCommon 3 }
neLocationCity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Location City of Network Element.
Writable size depends on net element controller, default 32"
::= { neCommon 4 }
neObsolete_UsingAPS OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neCommon 5 }
neObsolete_APSMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neCommon 6 }
-- #####+1 Space reserved
neObsolete_CommonSubrackWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete.
(The width of the Subracks)"
::= { neCommon 8 }
neObsolete_CommonSubrackNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete.
(The number of Subracks)"
::= { neCommon 9 }
neObsolete_NumberModul OBJECT-TYPE
SYNTAX INTEGER (1..61)
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete.
(Current number of entries in the Modul table)"
::= { neCommon 10 }
neObsolete_UsingRevertiveMode OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neCommon 11 }
neObsolete_RevertiveMode OBJECT-TYPE
SYNTAX INTEGER (0..300)
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neCommon 12 }
neObsolete_InitPhase OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neCommon 13 }
neObsolete_PredecessorRedundantPath OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neCommon 14 }
neObsolete_PredecessorNominalPath OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neCommon 15 }
neModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF NeModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table containing information about each Module."
::= { neCommon 16 }
neModuleEntry OBJECT-TYPE
SYNTAX NeModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of information about each Module."
INDEX { neModuleNESlot }
::= { neModuleTable 1 }
NeModuleEntry ::= SEQUENCE
{
neModuleNESlot NESlotValue,
neModuleSubrack INTEGER,
neModuleModelName DisplayString,
neModuleMibLink OBJECT IDENTIFIER,
neModuleSubrackSlot INTEGER,
neModuleSlotUnitsUsed INTEGER,
neModuleSlotRackDetection INTEGER,
neModuleHousingType INTEGER,
neModuleFirmwareVersion DisplayString,
neModuleHardwareVersion DisplayString,
neModuleDateOfProduction DisplayString,
neModuleSerialNumber DisplayString,
neModuleArticleNumber DisplayString,
neModuleCustomerCode DisplayString,
neModuleAliasName DisplayString,
neModuleUserdata DisplayString,
neModuleReset TruthValue,
neModuleLedBlink TruthValue
}
neModuleNESlot OBJECT-TYPE -- former neNESlot
SYNTAX NESlotValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot number
IMPORTANT NOTE:
this is a not a physical slot within a module rack,
but an assigned slot ID that uniquely identifies each module
including non subrack based modules as 19 inch modules"
::= { neModuleEntry 1 }
neModuleSubrack OBJECT-TYPE -- former neSubrack
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subrack number in which the module is equiped (1 .. N).
A value of 0 means: No subrack number"
::= { neModuleEntry 2 }
neModuleModelName OBJECT-TYPE -- former neModulType
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module model name"
::= { neModuleEntry 3 }
neModuleMibLink OBJECT-TYPE -- former neModulMibLink
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Defines the link to the OID of the equiped module"
::= { neModuleEntry 4 }
-- Expansions, 12.05.2014
neModuleSubrackSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot number within subrack in which the module is equiped (1 .. N).
A value of 0 means: No slot number"
::= { neModuleEntry 5 }
neModuleSlotUnitsUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used.
For all other module types the number of slots within subrack which the module occupies."
::= { neModuleEntry 6 }
neModuleSlotRackDetection OBJECT-TYPE
SYNTAX INTEGER
{
notSupported(1),
supported(2),
detectionError(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Reports the state of modules slot and rack hardware detection."
::= { neModuleEntry 7 }
neModuleHousingType OBJECT-TYPE
SYNTAX INTEGER
{
housingUnknownOrDefault(1),
housingBk(2),
housing2G6(3),
housing19inch(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module housing type"
::= { neModuleEntry 8 }
neModuleFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module firmware version"
::= { neModuleEntry 9 }
neModuleHardwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module hardware version"
::= { neModuleEntry 10 }
neModuleDateOfProduction OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module date of production, possible formats:
- empty string -> no data defined
- YYYY -> only the year of production is defined
- YYYY-MM-DD -> full date of production is defined"
::= { neModuleEntry 11 }
neModuleSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module serial number"
::= { neModuleEntry 12 }
neModuleArticleNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Module article number"
::= { neModuleEntry 13 }
neModuleCustomerCode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Customer specific article code"
::= { neModuleEntry 14 }
neModuleAliasName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Module alias name"
::= { neModuleEntry 15 }
neModuleUserdata OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Module user data"
::= { neModuleEntry 16 }
neModuleReset OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION "Resets the module if this parameter is written to true(1)."
::= { neModuleEntry 17 }
neModuleLedBlink OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION "Writing this variable to true(1) lets the device's
modul LED blink green for 10 seconds.
Writing this variable to false(2) stops blinking at once.
This variable always returns false(2) on read requests"
::= { neModuleEntry 18 }
neStates OBJECT IDENTIFIER ::= { ne 2 }
neStatesObsolete_TrapDisable OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neStates 1 }
neStatesObsolete_TerminalConnected OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neStates 2 }
-- #####+1 Space reserved
neStatesObsolete_Isolated OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neStates 4 }
neStatesObsolete_ResetModullist OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neStates 5 }
neStatesObsolete_Redundant OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neStates 6 }
neStatesObsolete_ActivateRedundantPath OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neStates 7 }
neStatesObsolete_AutoOff OBJECT-TYPE
SYNTAX PerceivedSeverityValue
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neStates 8 }
neConfig OBJECT IDENTIFIER ::= { ne 3 }
neConfigObsolete_NEtype OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neConfig 1 }
neConfigObsolete_IPaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neConfig 2 }
neConfigObsolete_Alarmdelay OBJECT-TYPE
SYNTAX INTEGER (3..60)
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neConfig 3 }
neConfigDeprecated_MinTrapInterval OBJECT-TYPE
SYNTAX INTEGER (0..10)
ACCESS read-write
STATUS optional
DESCRIPTION
"This parameter is deprecated.
(The minimum waiting time between two traps.
Only used for HMS070 over RS232 interface)"
::= { neConfig 4 }
neConfigDeprecated_MaxTrapLifetime OBJECT-TYPE
SYNTAX INTEGER (30..300)
ACCESS read-write
STATUS optional
DESCRIPTION
"This parameter is deprecated.
(The maximum lifetime of a trap.
Only used for HMS070 over RS232 interface)"
::= { neConfig 5 }
neControl OBJECT IDENTIFIER ::= { ne 4 }
neControlTrapDisable OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)"
::= { neControl 1 }
neControlResetModullist OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This command removes all disconnected (not responding) modules from the module list."
::= { neControl 2 }
neControlObsolete_SetDefaultAPS OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This parameter is obsolete."
::= { neControl 3 }
-- This trap is obsolete and no more supported by new (2014) NECxE
neSynchronizeEvent TRAP-TYPE
ENTERPRISE ne
DESCRIPTION "The SNMP trap that is generated when data on LMT must get actualized."
::= 1
END