1185 lines
40 KiB
Plaintext
1185 lines
40 KiB
Plaintext
|
--- ****************************************************************************
|
|||
|
-- *
|
|||
|
-- * Description: Implements definitions for the NECE
|
|||
|
-- *
|
|||
|
-- * Copyright 2003 by BKtel communications GmbH
|
|||
|
-- *
|
|||
|
-- * V.0.1 28.03.03 M. Heldmann first draft
|
|||
|
-- * V.0.2 31.03.03 M. Heldmann added GpioType
|
|||
|
-- * V.0.3 23.07.03 M. Heldmann modified descriptions for the states
|
|||
|
-- * V.0.4 05.01.04 M. Heldmann added two additional neceConfigTrapReceiver's and
|
|||
|
-- * configurable Get and Set Communities
|
|||
|
-- * V.1.0 19.03.04 M. Heldmann added neceConfigTrapReceiverVerify..neceConfigTrapAccumulationTime (ISDN dial up things)
|
|||
|
-- * neceDisplayTrapsSent, neceDisplayTrapsDiscarded
|
|||
|
-- * V.1.1 29.04.04 M. Heldmann added some descriptions
|
|||
|
-- * V.1.2 16.09.04 M. Heldmann added neceConfigHmsTrapsCompliance ... neceConfigFactoryInternal
|
|||
|
-- * V.1.3 08.12.04 M. Heldmann changed neceConfigFactoryInternal to neceConfigTimezone
|
|||
|
-- * M. Heldmann added neceConfigNtpServerIp ... neceConfigFactoryCommandLine
|
|||
|
-- * V.1.4 25.10.05 M. Heldmann changed name neceConfigNtpTimezone to neceConfigTimezone
|
|||
|
-- * M. Heldmann added neceConfigDaylightSavingFrom ... neceConfigDaylightSavingTo
|
|||
|
-- * V.1.5 13.09.06 M. Heldmann added neceStatesPowerSupplyLeft ... neceStatesFanRight
|
|||
|
-- * 29.09.06 M. Heldmann modified description for neceConfigCableWatchUsed
|
|||
|
-- * 04.10.06 M. Heldmann NESlotWriteValue expanded due to new 2G6 platform needs
|
|||
|
-- * V.1.6 27.05.08 M. Heldmann marked neceConfigHfcInventoryFormat as read-only
|
|||
|
-- * 29.05.08 M. Heldmann renamed threshold parameters in xxxxMeasuringValuesTable
|
|||
|
-- * V.1.7 16.09.09 M. Heldmann renamed type of neceConfigFactoryCommandLine from DisplayString to OCTET STRING
|
|||
|
-- * V.1.8 11.07.13 M. Heldmann adjusted syntax of "CommonEntry" to remove MIB compiler warnings
|
|||
|
-- * V.1.9 05.09.14 M. Heldmann changed CommonModuleWidth and ConfigNESlotWrite STATUS to optional
|
|||
|
-- ****************************************************************************
|
|||
|
|
|||
|
BKTEL-HFC862-NECE-MIB DEFINITIONS ::= BEGIN
|
|||
|
|
|||
|
IMPORTS
|
|||
|
experimental, enterprises, TimeTicks, IpAddress, Counter
|
|||
|
FROM RFC1155-SMI
|
|||
|
OBJECT-TYPE
|
|||
|
FROM RFC-1212
|
|||
|
TRAP-TYPE
|
|||
|
FROM RFC-1215
|
|||
|
modules, DisplayString, TruthValue, PerceivedSeverityValue, NESlotValue, ModuleWidthValue
|
|||
|
FROM BKTEL-HFC862-BASE-MIB
|
|||
|
;
|
|||
|
|
|||
|
nece OBJECT IDENTIFIER ::= { modules 100 }
|
|||
|
neceCommon OBJECT IDENTIFIER ::= { nece 1 }
|
|||
|
neceStates OBJECT IDENTIFIER ::= { nece 2 }
|
|||
|
neceConfiguration OBJECT IDENTIFIER ::= { nece 3 }
|
|||
|
neceControl OBJECT IDENTIFIER ::= { nece 4 }
|
|||
|
neceMeasuringValues OBJECT IDENTIFIER ::= { nece 5 }
|
|||
|
neceDisplay OBJECT IDENTIFIER ::= { nece 6 }
|
|||
|
|
|||
|
--
|
|||
|
-- Type definitions
|
|||
|
--
|
|||
|
|
|||
|
GpioType ::= INTEGER
|
|||
|
{
|
|||
|
gpioTypeNotSupported(1), -- port is not supported be this type of NEC
|
|||
|
gpioTypeInputOnly(2),
|
|||
|
gpioTypeInputOrOutput(3),
|
|||
|
gpioTypeOutputOnly(4)
|
|||
|
}
|
|||
|
|
|||
|
GpioMode ::= INTEGER
|
|||
|
{
|
|||
|
gpioModeInput(1),
|
|||
|
gpioModeInputIsNotify(2), -- only used for web interface
|
|||
|
gpioModeInputIsWarning(3),
|
|||
|
gpioModeInputIsAlarm(4),
|
|||
|
gpioModeOutputOnAnyAlarm(5), -- not usable for all gpio ports
|
|||
|
gpioModeOutputOnAnyWarning(6) -- not usable for all gpio ports
|
|||
|
}
|
|||
|
|
|||
|
GpioLogicLevel ::= INTEGER
|
|||
|
{
|
|||
|
gpioLevelActiveHigh(1),
|
|||
|
gpioLevelActiveLow(2)
|
|||
|
}
|
|||
|
|
|||
|
HmsTrapsComplianceValue ::= INTEGER
|
|||
|
{
|
|||
|
fullCompliant(1),
|
|||
|
minorCompliant(2) -- Default setting until NECE Software 1.10
|
|||
|
}
|
|||
|
|
|||
|
HfcInventoryFormatValue ::= INTEGER
|
|||
|
{
|
|||
|
format_DKS_T12_9(1),
|
|||
|
format_T_Nova_E531i(2) -- Default setting until NECE Software 1.10
|
|||
|
}
|
|||
|
|
|||
|
TrapVerifyTimeoutValue ::= INTEGER (30..600)
|
|||
|
|
|||
|
TrapAccumulationTimeValue ::= INTEGER (0..60)
|
|||
|
|
|||
|
NESlotWriteValue ::= INTEGER (-1..99)
|
|||
|
|
|||
|
|
|||
|
--*****************************************************************************************
|
|||
|
-- neceCommon group
|
|||
|
|
|||
|
neceCommonNumberOfModules OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Number of modules in table."
|
|||
|
::= { neceCommon 1 }
|
|||
|
|
|||
|
neceCommonTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF NeceCommonEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The table contains all modules of the nece-type in the NE"
|
|||
|
::= { neceCommon 2 }
|
|||
|
|
|||
|
neceCommonEntry OBJECT-TYPE
|
|||
|
SYNTAX NeceCommonEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Common-Values for a module."
|
|||
|
INDEX { neceNESlot }
|
|||
|
::= { neceCommonTable 1 }
|
|||
|
|
|||
|
-- the structure of the entry
|
|||
|
|
|||
|
NeceCommonEntry ::= SEQUENCE
|
|||
|
{
|
|||
|
neceNESlot NESlotValue,
|
|||
|
neceCommonType DisplayString,
|
|||
|
neceCommonDescr DisplayString,
|
|||
|
neceCommonFirmwareId DisplayString,
|
|||
|
neceCommonModuleWidth ModuleWidthValue
|
|||
|
}
|
|||
|
|
|||
|
neceNESlot OBJECT-TYPE
|
|||
|
SYNTAX NESlotValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The virtual slotID"
|
|||
|
::= { neceCommonEntry 1 }
|
|||
|
|
|||
|
neceCommonType OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE (0..32))
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Module model name"
|
|||
|
::= { neceCommonEntry 2 }
|
|||
|
|
|||
|
neceCommonDescr OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Module alias name"
|
|||
|
::= { neceCommonEntry 3 }
|
|||
|
|
|||
|
neceCommonFirmwareId OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE (0..32))
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Module firmware version"
|
|||
|
::= { neceCommonEntry 4 }
|
|||
|
|
|||
|
neceCommonModuleWidth OBJECT-TYPE
|
|||
|
SYNTAX ModuleWidthValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS optional
|
|||
|
DESCRIPTION "The width of the module."
|
|||
|
::= { neceCommonEntry 5 }
|
|||
|
|
|||
|
--*****************************************************************************************
|
|||
|
-- neceStates group
|
|||
|
|
|||
|
neceStatesTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF NeceStatesEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION ""
|
|||
|
::= { neceStates 1 }
|
|||
|
|
|||
|
-- table of states entry(ro/rw)
|
|||
|
|
|||
|
neceStatesEntry OBJECT-TYPE
|
|||
|
SYNTAX NeceStatesEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Alarms for a module."
|
|||
|
INDEX { neceNESlot }
|
|||
|
::= { neceStatesTable 1 }
|
|||
|
|
|||
|
-- the structure of the entry
|
|||
|
|
|||
|
NeceStatesEntry ::= SEQUENCE
|
|||
|
{
|
|||
|
neceStatesGpInput1 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput2 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput3 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput4 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput5 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput6 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput7 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput8 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput9 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput10 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput11 PerceivedSeverityValue,
|
|||
|
neceStatesGpInput12 PerceivedSeverityValue,
|
|||
|
neceStatesPowerSupplyLeft PerceivedSeverityValue,
|
|||
|
neceStatesPowerSupplyRight PerceivedSeverityValue,
|
|||
|
neceStatesFanLeft PerceivedSeverityValue,
|
|||
|
neceStatesFanRight PerceivedSeverityValue
|
|||
|
}
|
|||
|
|
|||
|
neceStatesGpInput1 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 1."
|
|||
|
::= { neceStatesEntry 1 }
|
|||
|
|
|||
|
neceStatesGpInput2 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 2."
|
|||
|
::= { neceStatesEntry 2 }
|
|||
|
|
|||
|
neceStatesGpInput3 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 3."
|
|||
|
::= { neceStatesEntry 3 }
|
|||
|
|
|||
|
neceStatesGpInput4 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 4."
|
|||
|
::= { neceStatesEntry 4 }
|
|||
|
|
|||
|
neceStatesGpInput5 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 5."
|
|||
|
::= { neceStatesEntry 5 }
|
|||
|
|
|||
|
neceStatesGpInput6 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 6."
|
|||
|
::= { neceStatesEntry 6 }
|
|||
|
|
|||
|
neceStatesGpInput7 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 7."
|
|||
|
::= { neceStatesEntry 7 }
|
|||
|
|
|||
|
neceStatesGpInput8 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 8."
|
|||
|
::= { neceStatesEntry 8 }
|
|||
|
|
|||
|
neceStatesGpInput9 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 9."
|
|||
|
::= { neceStatesEntry 9 }
|
|||
|
|
|||
|
neceStatesGpInput10 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 10."
|
|||
|
::= { neceStatesEntry 10 }
|
|||
|
|
|||
|
neceStatesGpInput11 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 11."
|
|||
|
::= { neceStatesEntry 11 }
|
|||
|
|
|||
|
neceStatesGpInput12 OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "State of general purpose input no. 12."
|
|||
|
::= { neceStatesEntry 12 }
|
|||
|
|
|||
|
neceStatesPowerSupplyLeft OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The left (looking from front side) power supply unit fails.
|
|||
|
Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5)"
|
|||
|
::= { neceStatesEntry 13 }
|
|||
|
|
|||
|
neceStatesPowerSupplyRight OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The right (looking from front side) power supply unit fails.
|
|||
|
Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5)"
|
|||
|
::= { neceStatesEntry 14 }
|
|||
|
|
|||
|
neceStatesFanLeft OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The left (looking from front side) fan unit fails.
|
|||
|
Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5)"
|
|||
|
::= { neceStatesEntry 15 }
|
|||
|
|
|||
|
neceStatesFanRight OBJECT-TYPE
|
|||
|
SYNTAX PerceivedSeverityValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The right (looking from front side) fan unit fails.
|
|||
|
Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5)"
|
|||
|
::= { neceStatesEntry 16 }
|
|||
|
|
|||
|
|
|||
|
--*****************************************************************************************
|
|||
|
-- neceConfiguration group
|
|||
|
|
|||
|
neceConfigurationTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF NeceConfigurationEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION ""
|
|||
|
::= { neceConfiguration 1 }
|
|||
|
|
|||
|
-- table of configuration entry(ro/rw)
|
|||
|
|
|||
|
neceConfigurationEntry OBJECT-TYPE
|
|||
|
SYNTAX NeceConfigurationEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION ""
|
|||
|
INDEX { neceNESlot }
|
|||
|
::= { neceConfigurationTable 1 }
|
|||
|
|
|||
|
-- the structure of the entry
|
|||
|
|
|||
|
NeceConfigurationEntry ::= SEQUENCE
|
|||
|
{
|
|||
|
neceConfigGpio1Type GpioType,
|
|||
|
neceConfigGpio1Mode GpioMode,
|
|||
|
neceConfigGpio1LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio1Description DisplayString,
|
|||
|
neceConfigGpio2Type GpioType,
|
|||
|
neceConfigGpio2Mode GpioMode,
|
|||
|
neceConfigGpio2LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio2Description DisplayString,
|
|||
|
neceConfigGpio3Type GpioType,
|
|||
|
neceConfigGpio3Mode GpioMode,
|
|||
|
neceConfigGpio3LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio3Description DisplayString,
|
|||
|
neceConfigGpio4Type GpioType,
|
|||
|
neceConfigGpio4Mode GpioMode,
|
|||
|
neceConfigGpio4LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio4Description DisplayString,
|
|||
|
neceConfigGpio5Type GpioType,
|
|||
|
neceConfigGpio5Mode GpioMode,
|
|||
|
neceConfigGpio5LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio5Description DisplayString,
|
|||
|
neceConfigGpio6Type GpioType,
|
|||
|
neceConfigGpio6Mode GpioMode,
|
|||
|
neceConfigGpio6LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio6Description DisplayString,
|
|||
|
neceConfigGpio7Type GpioType,
|
|||
|
neceConfigGpio7Mode GpioMode,
|
|||
|
neceConfigGpio7LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio7Description DisplayString,
|
|||
|
neceConfigGpio8Type GpioType,
|
|||
|
neceConfigGpio8Mode GpioMode,
|
|||
|
neceConfigGpio8LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio8Description DisplayString,
|
|||
|
neceConfigGpio9Type GpioType,
|
|||
|
neceConfigGpio9Mode GpioMode,
|
|||
|
neceConfigGpio9LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio9Description DisplayString,
|
|||
|
neceConfigGpio10Type GpioType,
|
|||
|
neceConfigGpio10Mode GpioMode,
|
|||
|
neceConfigGpio10LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio10Description DisplayString,
|
|||
|
neceConfigGpio11Type GpioType,
|
|||
|
neceConfigGpio11Mode GpioMode,
|
|||
|
neceConfigGpio11LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio11Description DisplayString,
|
|||
|
neceConfigGpio12Type GpioType,
|
|||
|
neceConfigGpio12Mode GpioMode,
|
|||
|
neceConfigGpio12LogicLevel GpioLogicLevel,
|
|||
|
neceConfigGpio12Description DisplayString,
|
|||
|
neceConfigNESlotWrite NESlotWriteValue,
|
|||
|
neceConfigIpAddress IpAddress,
|
|||
|
neceConfigNetmask IpAddress,
|
|||
|
neceConfigDefaultrouter IpAddress,
|
|||
|
neceConfigTrapReceiver1HostIp IpAddress,
|
|||
|
neceConfigTrapReceiver1Community DisplayString,
|
|||
|
neceConfigTrapReceiver2HostIp IpAddress,
|
|||
|
neceConfigTrapReceiver2to4Community DisplayString,
|
|||
|
neceConfigTrapReceiver3HostIp IpAddress,
|
|||
|
neceConfigTrapReceiver4HostIp IpAddress,
|
|||
|
neceConfigGetCommunity DisplayString,
|
|||
|
neceConfigSetCommunity DisplayString,
|
|||
|
neceConfigTrapReceiverVerify TruthValue,
|
|||
|
neceConfigTrapVerifyReceiverIp IpAddress,
|
|||
|
neceConfigTrapVerifyTimeout TrapVerifyTimeoutValue,
|
|||
|
neceConfigTrapAccumulationTime TrapAccumulationTimeValue,
|
|||
|
neceConfigCableWatchUsed TruthValue,
|
|||
|
neceConfigHmsTrapsCompliance HmsTrapsComplianceValue,
|
|||
|
neceConfigHmsNotificationsEnable TruthValue,
|
|||
|
neceConfigHfcInventoryFormat HfcInventoryFormatValue,
|
|||
|
neceConfigTimezone INTEGER,
|
|||
|
neceConfigNtpServerIp IpAddress,
|
|||
|
neceConfigFactoryCommandLine OCTET STRING,
|
|||
|
neceConfigDaylightSavingFrom DisplayString,
|
|||
|
neceConfigDaylightSavingTo DisplayString
|
|||
|
}
|
|||
|
|
|||
|
neceConfigGpio1Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 1"
|
|||
|
::={ neceConfigurationEntry 1 }
|
|||
|
|
|||
|
neceConfigGpio1Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 1"
|
|||
|
::={ neceConfigurationEntry 2 }
|
|||
|
|
|||
|
neceConfigGpio1LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 1"
|
|||
|
::={ neceConfigurationEntry 3 }
|
|||
|
|
|||
|
neceConfigGpio1Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 1"
|
|||
|
::={ neceConfigurationEntry 4 }
|
|||
|
|
|||
|
neceConfigGpio2Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 2"
|
|||
|
::={ neceConfigurationEntry 5 }
|
|||
|
|
|||
|
neceConfigGpio2Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 2"
|
|||
|
::={ neceConfigurationEntry 6 }
|
|||
|
|
|||
|
neceConfigGpio2LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 2"
|
|||
|
::={ neceConfigurationEntry 7 }
|
|||
|
|
|||
|
neceConfigGpio2Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 2"
|
|||
|
::={ neceConfigurationEntry 8 }
|
|||
|
|
|||
|
neceConfigGpio3Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 3"
|
|||
|
::={ neceConfigurationEntry 9 }
|
|||
|
|
|||
|
neceConfigGpio3Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 3"
|
|||
|
::={ neceConfigurationEntry 10 }
|
|||
|
|
|||
|
neceConfigGpio3LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 3"
|
|||
|
::={ neceConfigurationEntry 11 }
|
|||
|
|
|||
|
neceConfigGpio3Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 3"
|
|||
|
::={ neceConfigurationEntry 12 }
|
|||
|
|
|||
|
neceConfigGpio4Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 4"
|
|||
|
::={ neceConfigurationEntry 13 }
|
|||
|
|
|||
|
neceConfigGpio4Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 4"
|
|||
|
::={ neceConfigurationEntry 14 }
|
|||
|
|
|||
|
neceConfigGpio4LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 4"
|
|||
|
::={ neceConfigurationEntry 15 }
|
|||
|
|
|||
|
neceConfigGpio4Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 4"
|
|||
|
::={ neceConfigurationEntry 16 }
|
|||
|
|
|||
|
neceConfigGpio5Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 5"
|
|||
|
::={ neceConfigurationEntry 17 }
|
|||
|
|
|||
|
neceConfigGpio5Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 5"
|
|||
|
::={ neceConfigurationEntry 18 }
|
|||
|
|
|||
|
neceConfigGpio5LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 5"
|
|||
|
::={ neceConfigurationEntry 19 }
|
|||
|
|
|||
|
neceConfigGpio5Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 5"
|
|||
|
::={ neceConfigurationEntry 20 }
|
|||
|
|
|||
|
neceConfigGpio6Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 6"
|
|||
|
::={ neceConfigurationEntry 21 }
|
|||
|
|
|||
|
neceConfigGpio6Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 6"
|
|||
|
::={ neceConfigurationEntry 22 }
|
|||
|
|
|||
|
neceConfigGpio6LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 6"
|
|||
|
::={ neceConfigurationEntry 23 }
|
|||
|
|
|||
|
neceConfigGpio6Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 6"
|
|||
|
::={ neceConfigurationEntry 24 }
|
|||
|
|
|||
|
neceConfigGpio7Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 7"
|
|||
|
::={ neceConfigurationEntry 25 }
|
|||
|
|
|||
|
neceConfigGpio7Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 7"
|
|||
|
::={ neceConfigurationEntry 26 }
|
|||
|
|
|||
|
neceConfigGpio7LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 7"
|
|||
|
::={ neceConfigurationEntry 27 }
|
|||
|
|
|||
|
neceConfigGpio7Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 7"
|
|||
|
::={ neceConfigurationEntry 28 }
|
|||
|
|
|||
|
neceConfigGpio8Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 8"
|
|||
|
::={ neceConfigurationEntry 29 }
|
|||
|
|
|||
|
neceConfigGpio8Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 8"
|
|||
|
::={ neceConfigurationEntry 30 }
|
|||
|
|
|||
|
neceConfigGpio8LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 8"
|
|||
|
::={ neceConfigurationEntry 31 }
|
|||
|
|
|||
|
neceConfigGpio8Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 8"
|
|||
|
::={ neceConfigurationEntry 32 }
|
|||
|
|
|||
|
neceConfigGpio9Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 9"
|
|||
|
::={ neceConfigurationEntry 33 }
|
|||
|
|
|||
|
neceConfigGpio9Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 9"
|
|||
|
::={ neceConfigurationEntry 34 }
|
|||
|
|
|||
|
neceConfigGpio9LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 9"
|
|||
|
::={ neceConfigurationEntry 35 }
|
|||
|
|
|||
|
neceConfigGpio9Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 9"
|
|||
|
::={ neceConfigurationEntry 36 }
|
|||
|
|
|||
|
neceConfigGpio10Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 10"
|
|||
|
::={ neceConfigurationEntry 37 }
|
|||
|
|
|||
|
neceConfigGpio10Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 10"
|
|||
|
::={ neceConfigurationEntry 38 }
|
|||
|
|
|||
|
neceConfigGpio10LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 10"
|
|||
|
::={ neceConfigurationEntry 39 }
|
|||
|
|
|||
|
neceConfigGpio10Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 10"
|
|||
|
::={ neceConfigurationEntry 40 }
|
|||
|
|
|||
|
neceConfigGpio11Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 11"
|
|||
|
::={ neceConfigurationEntry 41 }
|
|||
|
|
|||
|
neceConfigGpio11Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 11"
|
|||
|
::={ neceConfigurationEntry 42 }
|
|||
|
|
|||
|
neceConfigGpio11LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 11"
|
|||
|
::={ neceConfigurationEntry 43 }
|
|||
|
|
|||
|
neceConfigGpio11Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 11"
|
|||
|
::={ neceConfigurationEntry 44 }
|
|||
|
|
|||
|
neceConfigGpio12Type OBJECT-TYPE
|
|||
|
SYNTAX GpioType
|
|||
|
ACCESS read-only -- READONLY !!!
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The type of the general purpose port no. 12"
|
|||
|
::={ neceConfigurationEntry 45 }
|
|||
|
|
|||
|
neceConfigGpio12Mode OBJECT-TYPE
|
|||
|
SYNTAX GpioMode
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The mode of the general purpose port no. 12"
|
|||
|
::={ neceConfigurationEntry 46 }
|
|||
|
|
|||
|
neceConfigGpio12LogicLevel OBJECT-TYPE
|
|||
|
SYNTAX GpioLogicLevel
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"The logic level of the general purpose port no. 12"
|
|||
|
::={ neceConfigurationEntry 47 }
|
|||
|
|
|||
|
neceConfigGpio12Description OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION
|
|||
|
"A description for the general purpose port no. 12"
|
|||
|
::={ neceConfigurationEntry 48 }
|
|||
|
|
|||
|
|
|||
|
neceConfigNESlotWrite OBJECT-TYPE
|
|||
|
SYNTAX NESlotWriteValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS optional
|
|||
|
DESCRIPTION "By writing this variable a slot can be assigned
|
|||
|
for devices that dont support hardware slot detection.
|
|||
|
Reading '-1' means that the slot position is NOT writable."
|
|||
|
::= { neceConfigurationEntry 49 }
|
|||
|
|
|||
|
neceConfigIpAddress OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The ip address of the NEC.
|
|||
|
NOTE: The NECE executes a reset if this parameter gets changed"
|
|||
|
::= { neceConfigurationEntry 50 }
|
|||
|
|
|||
|
neceConfigNetmask OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The netmask of the NEC.
|
|||
|
NOTE: The NECE executes a reset if this parameter gets changed"
|
|||
|
::= { neceConfigurationEntry 51 }
|
|||
|
|
|||
|
neceConfigDefaultrouter OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The default router of the NEC.
|
|||
|
NOTE: The NECE executes a reset if this parameter gets changed"
|
|||
|
::= { neceConfigurationEntry 52 }
|
|||
|
|
|||
|
neceConfigTrapReceiver1HostIp OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The ip address of the host no.1 that should receive traps
|
|||
|
Address 0.0.0.0 disables the trap. Broad- or multicast addresses
|
|||
|
are not allowed"
|
|||
|
::= { neceConfigurationEntry 53 }
|
|||
|
|
|||
|
neceConfigTrapReceiver1Community OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(4..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The community name used for traps to host no.1"
|
|||
|
::= { neceConfigurationEntry 54 }
|
|||
|
|
|||
|
neceConfigTrapReceiver2HostIp OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The ip address of the host no.2 that should receive traps
|
|||
|
Address 0.0.0.0 disables the trap. Broad- or multicast addresses
|
|||
|
are not allowed"
|
|||
|
::= { neceConfigurationEntry 55 }
|
|||
|
|
|||
|
neceConfigTrapReceiver2to4Community OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(4..31))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The community name used for traps to hosts no.2 to no.4"
|
|||
|
::= { neceConfigurationEntry 56 }
|
|||
|
|
|||
|
neceConfigTrapReceiver3HostIp OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The ip address of the host no.3 that should receive traps
|
|||
|
Address 0.0.0.0 disables the trap. Broad- or multicast addresses
|
|||
|
are not allowed
|
|||
|
NOTE: The community name 'neceConfigTrapReceiver2to4Community' is
|
|||
|
used for this trap receiver no. 3"
|
|||
|
::= { neceConfigurationEntry 57 }
|
|||
|
|
|||
|
neceConfigTrapReceiver4HostIp OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The ip address of the host no.4 that should receive traps
|
|||
|
Address 0.0.0.0 disables the trap. Broad- or multicast addresses
|
|||
|
are not allowed
|
|||
|
NOTE: The community name 'neceConfigTrapReceiver2to4Community' is
|
|||
|
used for this trap receiver no. 4"
|
|||
|
::= { neceConfigurationEntry 58 }
|
|||
|
|
|||
|
neceConfigGetCommunity OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..15))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The community name that is allowed for GET requests
|
|||
|
NOTES:
|
|||
|
- By writing 'neceConfigGetCommunity' AND 'neceConfigSetCommunity'
|
|||
|
to an empty string of size 0, the default community settings
|
|||
|
are used."
|
|||
|
::= { neceConfigurationEntry 59 }
|
|||
|
|
|||
|
neceConfigSetCommunity OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(0..15))
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The community name that is allowed for SET and GET requests
|
|||
|
NOTES:
|
|||
|
- By writing 'neceConfigGetCommunity' AND 'neceConfigSetCommunity'
|
|||
|
to an empty string of size 0, the default community settings
|
|||
|
are used."
|
|||
|
::= { neceConfigurationEntry 60}
|
|||
|
|
|||
|
neceConfigTrapReceiverVerify OBJECT-TYPE
|
|||
|
SYNTAX TruthValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "If TRUE, the NECE verifies if the 'sysDescr' variable is readable on host
|
|||
|
with ip-address 'neceConfigTrapVerifyReceiverIp' before sending new traps.
|
|||
|
NOTE: The NECE executes a reset if this parameter gets changed"
|
|||
|
::= { neceConfigurationEntry 61 }
|
|||
|
|
|||
|
neceConfigTrapVerifyReceiverIp OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The ip address of the host that should receive the 'sysDescr' verify request.
|
|||
|
Broad- or multicast addresses are not allowed.
|
|||
|
!!! Only valid if neceConfigTrapReceiverVerify == true(1) !!!"
|
|||
|
::= { neceConfigurationEntry 62 }
|
|||
|
|
|||
|
neceConfigTrapVerifyTimeout OBJECT-TYPE
|
|||
|
SYNTAX TrapVerifyTimeoutValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Timeout in seconds after which the NECE stops trying to verify 'sysDescr'.
|
|||
|
All pending traps are sent, although no verify response, after that timeout.
|
|||
|
!!! Only valid if neceConfigTrapReceiverVerify == true(1) !!!"
|
|||
|
::= { neceConfigurationEntry 63 }
|
|||
|
|
|||
|
neceConfigTrapAccumulationTime OBJECT-TYPE
|
|||
|
SYNTAX TrapAccumulationTimeValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Time in seconds that the NECE waits before sending all pending traps.
|
|||
|
NOTE: There are two condition where the NECE sends its pending traps earlier
|
|||
|
ignoring this accumulation time (of course verifying first):
|
|||
|
1) The NECE's internal trap buffer is 3/4 full
|
|||
|
2) The NECE's SNMP agent is polled by a request from manager
|
|||
|
!!! Only valid if neceConfigTrapReceiverVerify == true(1) !!!"
|
|||
|
::= { neceConfigurationEntry 64 }
|
|||
|
|
|||
|
neceConfigCableWatchUsed OBJECT-TYPE
|
|||
|
SYNTAX TruthValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "This parameter is obsolete and no more needed, always returns false(2)"
|
|||
|
::= { neceConfigurationEntry 65 }
|
|||
|
|
|||
|
neceConfigHmsTrapsCompliance OBJECT-TYPE
|
|||
|
SYNTAX HmsTrapsComplianceValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Set the compliance mode of the SCTE HMS traps
|
|||
|
In earlier versions of NECE (<= Sw.Rel. 1.10) the trap compliance
|
|||
|
to the SCTE HMS MIBs was not fully given. See manual for details."
|
|||
|
::= { neceConfigurationEntry 66 }
|
|||
|
|
|||
|
neceConfigHmsNotificationsEnable OBJECT-TYPE
|
|||
|
SYNTAX TruthValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "With this control the user can disable all traps of type NOTIFY
|
|||
|
and there entries in the SCTE HMS tree.
|
|||
|
NOTE: The NECE executes a reset if this parameter gets changed"
|
|||
|
::= { neceConfigurationEntry 67 }
|
|||
|
|
|||
|
neceConfigHfcInventoryFormat OBJECT-TYPE
|
|||
|
SYNTAX HfcInventoryFormatValue
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Selects the supported format of the hfcInventoryFabricData (T-NOVA-HFC-INVENTORY-MIB)"
|
|||
|
::= { neceConfigurationEntry 68 }
|
|||
|
|
|||
|
neceConfigTimezone OBJECT-TYPE
|
|||
|
SYNTAX INTEGER (-24..24)
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The timezone in units of half hours from GMT (Greenwich Mean Time).
|
|||
|
For example:
|
|||
|
Berlin => +2 half hours means GMT+1 hour
|
|||
|
Tokio => +18 half hours means GMT+9 hours
|
|||
|
NewYork => -10 half hours means GMT-5 hours
|
|||
|
NOTE: Not all NECE's support an NTP server."
|
|||
|
::= { neceConfigurationEntry 69 }
|
|||
|
|
|||
|
neceConfigNtpServerIp OBJECT-TYPE
|
|||
|
SYNTAX IpAddress
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "The ip address of an NTP time server.
|
|||
|
Setting the ip to 0.0.0.0 disables the time server lookup.
|
|||
|
NOTE: Not all NECE's support an NTP server."
|
|||
|
::= { neceConfigurationEntry 70 }
|
|||
|
|
|||
|
neceConfigFactoryCommandLine OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "A factory internal command interface"
|
|||
|
::= { neceConfigurationEntry 71}
|
|||
|
|
|||
|
neceConfigDaylightSavingFrom OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Daylight saving start time in a special textformat (see manual for detail)"
|
|||
|
::= { neceConfigurationEntry 72}
|
|||
|
|
|||
|
neceConfigDaylightSavingTo OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Daylight saving end time in a special textformat (see manual for detail)"
|
|||
|
::= { neceConfigurationEntry 73}
|
|||
|
|
|||
|
|
|||
|
--*****************************************************************************************
|
|||
|
-- neceControl group
|
|||
|
|
|||
|
neceControlTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF NeceControlEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION ""
|
|||
|
::= { neceControl 1 }
|
|||
|
|
|||
|
-- table of control entry(ro/rw)
|
|||
|
|
|||
|
neceControlEntry OBJECT-TYPE
|
|||
|
SYNTAX NeceControlEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Alarms for a module."
|
|||
|
INDEX { neceNESlot }
|
|||
|
::= { neceControlTable 1 }
|
|||
|
|
|||
|
-- the structure of the entry
|
|||
|
|
|||
|
NeceControlEntry ::= SEQUENCE
|
|||
|
{
|
|||
|
neceControlReset TruthValue
|
|||
|
}
|
|||
|
|
|||
|
neceControlReset OBJECT-TYPE
|
|||
|
SYNTAX TruthValue
|
|||
|
ACCESS read-write
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Reset the module."
|
|||
|
::= { neceControlEntry 1 }
|
|||
|
|
|||
|
|
|||
|
|
|||
|
--*****************************************************************************************
|
|||
|
-- neceMeasuringValues group
|
|||
|
|
|||
|
-- table of measuring Values
|
|||
|
|
|||
|
neceMeasuringValuesTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF NeceMeasuringValuesEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION ""
|
|||
|
::= { neceMeasuringValues 1 }
|
|||
|
|
|||
|
-- table of measuring Values entry
|
|||
|
|
|||
|
neceMeasuringValuesEntry OBJECT-TYPE
|
|||
|
SYNTAX NeceMeasuringValuesEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Common-Values for a module."
|
|||
|
INDEX { neceNESlot }
|
|||
|
::= { neceMeasuringValuesTable 1 }
|
|||
|
|
|||
|
-- the structure of the entry
|
|||
|
|
|||
|
NeceMeasuringValuesEntry ::= SEQUENCE
|
|||
|
{
|
|||
|
neceTemperatureLoLo INTEGER,
|
|||
|
neceTemperatureLo INTEGER,
|
|||
|
neceTemperatureValue INTEGER,
|
|||
|
neceTemperatureHi INTEGER,
|
|||
|
neceTemperatureHiHi INTEGER
|
|||
|
}
|
|||
|
|
|||
|
neceTemperatureLoLo OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Temperature low alarm threshold in steps of 0,1<>C."
|
|||
|
::= { neceMeasuringValuesEntry 1 }
|
|||
|
|
|||
|
neceTemperatureLo OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Temperature low warning threshold in steps of 0,1<>C."
|
|||
|
::= { neceMeasuringValuesEntry 2 }
|
|||
|
|
|||
|
neceTemperatureValue OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Temperature in steps of 0,1<>C."
|
|||
|
::= { neceMeasuringValuesEntry 3 }
|
|||
|
|
|||
|
neceTemperatureHi OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Temperature high warning threshold in steps of 0,1<>C."
|
|||
|
::= { neceMeasuringValuesEntry 4 }
|
|||
|
|
|||
|
neceTemperatureHiHi OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Temperature high alarm threshold in steps of 0,1<>C."
|
|||
|
::= { neceMeasuringValuesEntry 5 }
|
|||
|
|
|||
|
|
|||
|
--*****************************************************************************************
|
|||
|
-- Display group
|
|||
|
|
|||
|
neceDisplayTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF NeceDisplayEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION ""
|
|||
|
::= { neceDisplay 1 }
|
|||
|
|
|||
|
-- table of configuration entry(ro/rw)
|
|||
|
|
|||
|
neceDisplayEntry OBJECT-TYPE
|
|||
|
SYNTAX NeceDisplayEntry
|
|||
|
ACCESS not-accessible
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION ""
|
|||
|
INDEX { neceNESlot }
|
|||
|
::= { neceDisplayTable 1 }
|
|||
|
|
|||
|
-- the structure of the entry
|
|||
|
|
|||
|
NeceDisplayEntry ::= SEQUENCE
|
|||
|
{
|
|||
|
neceDisplayTrapsSent INTEGER,
|
|||
|
neceDisplayTrapsDiscarded INTEGER
|
|||
|
}
|
|||
|
|
|||
|
neceDisplayTrapsSent OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Number of traps that the NECE has sent."
|
|||
|
::= { neceDisplayEntry 1 }
|
|||
|
|
|||
|
neceDisplayTrapsDiscarded OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
ACCESS read-only
|
|||
|
STATUS mandatory
|
|||
|
DESCRIPTION "Number of traps that the NECE has discarded.
|
|||
|
Discarded traps occur because of trap buffer overflow or timeouts."
|
|||
|
::= { neceDisplayEntry 2 }
|
|||
|
|
|||
|
END
|
|||
|
--*****************************************************************************************--
|