mibs/MIBS/cambium/CAMBIUM-PTP650-MIB

6087 lines
210 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
CAMBIUM-PTP650-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress,
enterprises
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC
InetAddress, InetAddressType
FROM INET-ADDRESS-MIB;
cambium MODULE-IDENTITY
LAST-UPDATED "201502060443Z"
ORGANIZATION "Cambium Networks Ltd."
CONTACT-INFO
"Post: Simon Whitaker
Cambium Networks Ltd.
Unit B2,
Linhay Business Park,
Eastern Road,
Ashburton,
Devon.
TQ13 7UP
United Kingdom
Phone: +44 (0) 1364 655 500
Email: simon.whitaker@cambiumnetworks.com"
DESCRIPTION
"MIB for non-line-of-sight (NLOS) wireless ethernet bridge."
REVISION "201502060443Z"
DESCRIPTION
"PTP650-01-40:
Added Second Data Service attributes to support a second data path over
wireless link.
Added support for Cable Diagnostics.
Added IEEE 1588 Transparent Clock source port and Transparent Clock source
alarm attributes."
REVISION "201406181412Z"
DESCRIPTION
"PTP650-01-20:
Added TDM group and NIDU attributes to support the telecomms interfaces.
Added Router Protocols group to support Microwave Adaptive Bandwidth (MAB).
Added support for Out-Of-Band Remote Management, and for mute and enable
transmission. Renamed 'ethernet bridging' attributes to 'data bridging'.
Made more SyncE attributes writable."
REVISION "201402211503Z"
DESCRIPTION
"PTP650-01-10:
Added Synchronous Ethernet (SyncE) and IEEE 1588 Transparent Clock.
Support PTP650s. Clarified localPacketFiltering, regulatoryBand,
TDD Sync status & alarm. TX power max increased to 30dBm.
Modified the bit assignments of enabledDiagnosticAlarms to combine
the various status & warning bits for the main PSU, Aux & SFP ports
into a single portState bit."
REVISION "201308021028Z"
DESCRIPTION "PTP650-01-00: Initial revision."
::= { enterprises 17713 }
-- Groups in cambium
ptp OBJECT IDENTIFIER ::= { cambium 1 }
ptmp OBJECT IDENTIFIER ::= { cambium 2 }
ptp650 OBJECT IDENTIFIER ::= { cambium 7 }
-- Groups in ptp650
dfs OBJECT IDENTIFIER ::= { ptp650 3 }
bridge OBJECT IDENTIFIER ::= { ptp650 4 }
configuration OBJECT IDENTIFIER ::= { ptp650 5 }
ethernet OBJECT IDENTIFIER ::= { ptp650 6 }
tDM OBJECT IDENTIFIER ::= { ptp650 7 }
license OBJECT IDENTIFIER ::= { ptp650 8 }
management OBJECT IDENTIFIER ::= { ptp650 9 }
phyControl OBJECT IDENTIFIER ::= { ptp650 10 }
phyStatus OBJECT IDENTIFIER ::= { ptp650 12 }
alarms OBJECT IDENTIFIER ::= { ptp650 13 }
smtp OBJECT IDENTIFIER ::= { ptp650 15 }
snmpControl OBJECT IDENTIFIER ::= { ptp650 16 }
sntp OBJECT IDENTIFIER ::= { ptp650 17 }
reset OBJECT IDENTIFIER ::= { ptp650 18 }
versions OBJECT IDENTIFIER ::= { ptp650 19 }
pubStats OBJECT IDENTIFIER ::= { ptp650 20 }
encryption OBJECT IDENTIFIER ::= { ptp650 22 }
tDDControl OBJECT IDENTIFIER ::= { ptp650 23 }
aAAControl OBJECT IDENTIFIER ::= { ptp650 25 }
syslogControl OBJECT IDENTIFIER ::= { ptp650 24 }
routerProtocols OBJECT IDENTIFIER ::= { ptp650 26 }
cableDiagnostics OBJECT IDENTIFIER ::= { ptp650 27 }
supplementary OBJECT IDENTIFIER ::= { ptp650 96 }
ptpGroups OBJECT IDENTIFIER ::= { ptp650 98 }
ptpTraps OBJECT IDENTIFIER ::= { ptp650 99 }
ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 }
-- Compliance information
--
ptpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Cambium PTP MIB"
MODULE -- this module
MANDATORY-GROUPS { dfsGroup
, bridgeGroup
, configurationGroup
, ethernetGroup
, tDMGroup
, licenseGroup
, managementGroup
, phyControlGroup
, phyStatusGroup
, alarmsGroup
, smtpGroup
, snmpControlGroup
, sntpGroup
, resetGroup
, versionsGroup
, pubStatsGroup
, encryptionGroup
, tDDControlGroup
, aAAControlGroup
, syslogControlGroup
, routerProtocolsGroup
, cableDiagnosticsGroup
, supplementaryGroup
, notificationsGroup
}
::= { ptp650 97 }
dfsGroup OBJECT-GROUP
OBJECTS { dfsTableNumber
, extendedSpectrumScanning
, dfsMeans
, dfsNineNinePointNinePercentiles
, dfsPeaks
}
STATUS current
DESCRIPTION "The dfs object group."
::= { ptpGroups 3 }
bridgeGroup OBJECT-GROUP
OBJECTS { localPacketFiltering
}
STATUS current
DESCRIPTION "The bridge object group."
::= { ptpGroups 4 }
configurationGroup OBJECT-GROUP
OBJECTS { iPv4Address
, subnetMask
, gatewayIPAddress
, targetMACAddress
, masterSlaveMode
, maximumTransmitPower
, antennaGain
, cableLoss
, eIRP
, channelBandwidth
, linkName
, siteName
, accessMethod
, groupID
, iPv6Address
, iPVersion
, iPv6AutoConfiguredLinkLocalAddress
, iPv6PrefixLength
, iPv6GatewayAddress
, remoteInternetAddressType
, remoteInternetAddress
, subbandLowestFrequency
, subbandHighestFrequency
, enableTransmission
}
STATUS current
DESCRIPTION "The configuration object group."
::= { ptpGroups 5 }
ethernetGroup OBJECT-GROUP
OBJECTS { mainPSUPortAutoNegotiation
, mainPSUPortAutoNegAdvertisement
, mainPSUPortAutoMdix
, mainPSUPortStatus
, mainPSUPortSpeedAndDuplex
, dataPortWirelessDownAlert
, useVLANForManagementInterfaces
, vLANManagementPriority
, vLANManagementVID
, auxPortStatus
, auxPortSpeedAndDuplex
, ethernetPriorityTableNumber
, l2CPPriorityTableNumber
, iPDSCPPriorityTableNumber
, mPLSTCPriorityTableNumber
, managementPortWirelessDownAlert
, qOSPriorityScheme
, unknownNetworkPriorityQueueMapping
, dSCPManagementPriority
, dataBridgingStatus
, mainPSUPortAllocation
, auxPortAllocation
, sFPPortAllocation
, dataPortPauseFrames
, sFPPortAutoNegotiation
, sFPPortAutoNegAdvertisement
, sFPPortAutoMdix
, sFPPortStatus
, sFPPortSpeedAndDuplex
, auxPortPowerOverEthernetOutput
, auxPortPowerOverEthernetOutputStatus
, syncETracking
, syncEEquipmentClock
, mainPSUPortQLRxOverwrite
, mainPSUPortSSMTx
, sFPPortSSMTx
, auxPortSSMTx
, syncETrackingState
, mainPSUPortQLRx
, auxPortQLRx
, sFPPortQLRx
, mainPSUPortQLTx
, auxPortQLTx
, sFPPortQLTx
, mainPSUPortSyncEMasterSlaveStatus
, auxPortSyncEMasterSlaveStatus
, sFPPortSyncEMasterSlaveStatus
, mainPSUPortGigabitMasterSlaveStatus
, auxPortGigabitMasterSlaveStatus
, sFPPortGigabitMasterSlaveStatus
, transparentClock
, transparentClockVLAN
, transparentClockVID
, mainPSUPortAcceptedQLRx
, auxPortAcceptedQLRx
, sFPPortAcceptedQLRx
, mainPSUPortSyncERxStatus
, auxPortSyncERxStatus
, sFPPortSyncERxStatus
, nIDULanPortStatus
, nIDULanPortSpeedAndDuplex
, oOBPriorityQueueMapping
, nIDULanPortAutoNegotiation
, nIDULanPortAutoNegAdvertisement
, nIDULanPortAutoMdix
, nIDULanPortGigabitMasterSlaveStatus
, txMABFrames
, managementNetworkAccessEnabled
, secondDataPortPauseFrames
, secondDataBridgingStatus
, transparentClockPort
, ethernetPriorityQueueMapping
, l2CPPriorityQueueMapping
, iPDSCPPriorityQueueMapping
, mPLSTCPriorityQueueMapping
}
STATUS current
DESCRIPTION "The ethernet object group."
::= { ptpGroups 6 }
tDMGroup OBJECT-GROUP
OBJECTS { tDMInterfaceControl
, tDMInterfaceStatus
, tDMEnabledChannels
, tdmTableNumber
, tDMConfigurationMismatch
, lowestTDMModulationMode
, tDMChannelStatus
, tDMChannelLineCode
, tDMChannelCableLength
, tDMChannelLoopback
}
STATUS current
DESCRIPTION "The tDM object group."
::= { ptpGroups 7 }
licenseGroup OBJECT-GROUP
OBJECTS { regulatoryBand
, productVariant
, productName
, frequencyVariant
, sNMPv3Enable
, licenseVersion
, licenseUnitSerialNumber
, licenseIssueNumber
, licenseCountry
, licenseNumberOfRegulatoryBands
, licenseBandwidthCap
, licenseEncryption
, licenseSecurityLevel
, licenseGroupAccess
, licenseOOBManagementSupport
, licenseSFPPortSupport
, licenseAuxiliaryPortSupport
, licenseCapacity
, licenseMaxNumberOfTDMChannels
, licenseIEEE1588Support
, licenseSyncESupport
, licenseIPv6Support
, licenseMinimumFirmwareVersion
, licenseFullCapabilityTrialStatus
, licenseRemainingTrialPeriod
, licenseRemainingTrialPeriodAlarm
, capacityVariantMismatch
, licenseTDDSyncSupport
, licenseMaxLinkRange
, licenseTrialPeriod
, licenseRARSupport
, licenseRegulatoryBandsList
}
STATUS current
DESCRIPTION "The license object group."
::= { ptpGroups 8 }
managementGroup OBJECT-GROUP
OBJECTS { targetRange
, rangingMode
, installStatus
, installArmState
, tFTPServerPortNumber
, tFTPSoftwareUpgradeFileName
, tFTPStartSoftwareUpgrade
, tFTPSoftwareUpgradeStatus
, tFTPSoftwareUpgradeStatusText
, tFTPSoftwareUpgradeStatusAdditionalText
, hTTPAccessEnabled
, telnetAccessEnabled
, hTTPPortNumber
, hTTPSPortNumber
, telnetPortNumber
, hTTPSAccessEnabled
, tFTPServerInternetAddressType
, tFTPServerInternetAddress
, lowestDataModulationMode
, lowestSecondDataModulationMode
}
STATUS current
DESCRIPTION "The management object group."
::= { ptpGroups 9 }
phyControlGroup OBJECT-GROUP
OBJECTS { linkSymmetry
, userConfiguredMaxModulationMode
, linkModeOptimization
, txColorCode
, rxColorCode
, remoteMaximumTransmitPower
}
STATUS current
DESCRIPTION "The phyControl object group."
::= { ptpGroups 10 }
phyStatusGroup OBJECT-GROUP
OBJECTS { linkLoss
, receivePower
, vectorError
, transmitPower
, receiveChannel
, transmitChannel
, receiveFreqMHz
, transmitFreqMHz
, signalStrengthRatio
, receiveFreqKHz
, transmitFreqKHz
, rawReceivePower
, range
, receiveModulationMode
, transmitModulationMode
, searchState
}
STATUS current
DESCRIPTION "The phyStatus object group."
::= { ptpGroups 12 }
alarmsGroup OBJECT-GROUP
OBJECTS { unitOutOfCalibration
, incompatibleRegulatoryBands
, noWirelessChannelAvailable
, wirelessLinkDisabledWarning
, mainPSUPortDisabledWarning
, sFPError
, mainPSUPortConfigurationMismatch
, incompatibleMasterAndSlave
, tDDSynchronizationStatus
, auxPortDisabledWarning
, tDDSynchronizationAlarm
, linkModeOptimizationMismatch
, auxPortConfigurationMismatch
, secureModeAlarm
, dataBridgingStatusAlarm
, sFPPortDisabledWarning
, sFPPortConfigurationMismatch
, maxLinkRangeExceeded
, nIDULanPortDisabledWarning
, nIDULanPortConfigurationMismatch
, portAllocationMismatch
, secondDataBridgingStatusAlarm
, transparentClockSourcePortAlarm
}
STATUS current
DESCRIPTION "The alarms object group."
::= { ptpGroups 13 }
smtpGroup OBJECT-GROUP
OBJECTS { sMTPEmailAlert
, sMTPServerPortNumber
, sMTPSourceEmailAddress
, sMTPDestinationEmailAddress
, sMTPEnabledMessages
, sMTPServerInternetAddressType
, sMTPServerInternetAddress
}
STATUS current
DESCRIPTION "The smtp object group."
::= { ptpGroups 15 }
snmpControlGroup OBJECT-GROUP
OBJECTS { sNMPPortNumber
, sNMPCommunityString
, sNMPTrapTableNumber
, sNMPTrapVersion
, sNMPEnabledTraps
, enabledDiagnosticAlarms
, sNMPSendAllTrapsAtStartup
, sNMPTrapPortNumber
, sNMPTrapInternetAddressType
, sNMPTrapInternetAddress
, sNMPTrapReceiverEnabled
}
STATUS current
DESCRIPTION "The snmpControl object group."
::= { ptpGroups 16 }
sntpGroup OBJECT-GROUP
OBJECTS { sNTPState
, sNTPPollInterval
, sNTPSync
, sNTPLastSync
, systemClock
, timeZone
, daylightSaving
, sNTPPrimaryServer
, sNTPPrimaryServerDeadTime
, sNTPServerRetries
, sNTPServerTimeout
, sNTPServerTableNumber
, sNTPServerPortNumber
, sNTPServerStatus
, sNTPServerInternetAddressType
, sNTPServerInternetAddress
}
STATUS current
DESCRIPTION "The sntp object group."
::= { ptpGroups 17 }
resetGroup OBJECT-GROUP
OBJECTS { systemReset
}
STATUS current
DESCRIPTION "The reset object group."
::= { ptpGroups 18 }
versionsGroup OBJECT-GROUP
OBJECTS { softwareVersion
, hardwareVersion
, secondarySoftwareVersion
, bootVersion
}
STATUS current
DESCRIPTION "The versions object group."
::= { ptpGroups 19 }
pubStatsGroup OBJECT-GROUP
OBJECTS { receiveDataRate
, transmitDataRate
, aggregateDataRate
, wirelessLinkAvailability
, wirelessLinkStatus
, byteErrorRatio
, receiveModulationModeDetail
, dataBridgingAvailability
}
STATUS current
DESCRIPTION "The pubStats object group."
::= { ptpGroups 20 }
encryptionGroup OBJECT-GROUP
OBJECTS { encryptionAlgorithm
}
STATUS current
DESCRIPTION "The encryption object group."
::= { ptpGroups 22 }
tDDControlGroup OBJECT-GROUP
OBJECTS { tDDSynchronizationMode
}
STATUS current
DESCRIPTION "The tDDControl object group."
::= { ptpGroups 23 }
aAAControlGroup OBJECT-GROUP
OBJECTS { userTableNumber
, userName
, userRole
, userEnabled
, userPassword
}
STATUS current
DESCRIPTION "The aAAControl object group."
::= { ptpGroups 25 }
syslogControlGroup OBJECT-GROUP
OBJECTS { syslogClient
, syslogState
}
STATUS current
DESCRIPTION "The syslogControl object group."
::= { ptpGroups 24 }
routerProtocolsGroup OBJECT-GROUP
OBJECTS { microwaveAdaptiveBandwidth
, mABNominalModulationMode
, mABTransmissionInterval
, mABHoldoffPeriod
, mABMaintenanceLevel
, useVLANForMABProtocol
, mABProtocolVID
, mABProtocolVLANPriority
, mABState
, mABNominalTransmitCapacity
, mABCurrentTransmitCapacity
}
STATUS current
DESCRIPTION "The routerProtocols object group."
::= { ptpGroups 26 }
cableDiagnosticsGroup OBJECT-GROUP
OBJECTS { cableDiagnosticsPorts
, cableDiagnosticsControl
, cableDiagnosticsWarning
, cableDiagnosticsResultTableNumber
, cableDiagnosticsResultsDateTime
, cableDiagPair1Results
, cableDiagPair1Distance
, cableDiagPair2Results
, cableDiagPair2Distance
, cableDiagPair3Results
, cableDiagPair3Distance
, cableDiagPair4Results
, cableDiagPair4Distance
}
STATUS current
DESCRIPTION "The cableDiagnostics object group."
::= { ptpGroups 27 }
supplementaryGroup OBJECT-GROUP
OBJECTS { longitude
, latitude
, altitude
}
STATUS current
DESCRIPTION "The supplementary object group."
::= { ptpGroups 96 }
notificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { channelChangeTrap
, dfsImpulsiveInterferenceTrap
, mainPSUPortStatusTrap
, mainPSUPortDisabledWarningTrap
, mainPSUPortConfigurationMismatchTrap
, auxPortStatusTrap
, auxPortDisabledWarningTrap
, regulatoryBandTrap
, installStatusTrap
, installArmStateTrap
, unitOutOfCalibrationTrap
, auxPortPowerOverEthernetOutputStatusTrap
, incompatibleRegulatoryBandsTrap
, noWirelessChannelAvailableTrap
, wirelessLinkDisabledWarningTrap
, auxPortConfigurationMismatchTrap
, sFPErrorTrap
, sFPPortStatusTrap
, incompatibleMasterAndSlaveTrap
, sNTPSyncTrap
, tDDSynchronizationAlarmTrap
, sFPPortDisabledWarningTrap
, sFPPortConfigurationMismatchTrap
, linkModeOptimizationMismatchTrap
, tDMInterfaceStatusTrap
, tDMChannelStatusTrap
, tDMChannelLoopbackTrap
, nIDULanPortStatusTrap
, syslogStateTrap
, syslogLocalNearlyFullTrap
, syslogLocalWrappedTrap
, syslogClientTrap
, secureModeAlarmTrap
, dataBridgingStatusAlarmTrap
, licenseRemainingTrialPeriodAlarmTrap
, capacityVariantMismatchTrap
, maxLinkRangeExceededTrap
, tDMConfigurationMismatchTrap
, nIDULanPortDisabledWarningTrap
, nIDULanPortConfigurationMismatchTrap
, secondDataBridgingStatusAlarmTrap
, transparentClockSourcePortAlarmTrap
, portAllocationMismatchTrap
}
STATUS current
DESCRIPTION "The notifications group."
::= { ptpGroups 99 }
DfsTableEntry ::=
SEQUENCE { dfsTableIndex INTEGER
, dfsMeans Integer32
, dfsNineNinePointNinePercentiles Integer32
, dfsPeaks Integer32
}
dfsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A table storing a snapshot of various DFS measurements for each channel"
::= { dfs 2 }
dfsTableEntry OBJECT-TYPE
SYNTAX DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table DfsTable"
INDEX { dfsTableIndex }
::= { dfsTable 1 }
EthernetPriorityTableEntry ::=
SEQUENCE { ethernetPriorityTableIndex INTEGER
, ethernetPriorityQueueMapping INTEGER
}
ethernetPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority."
::= { ethernet 15 }
ethernetPriorityTableEntry OBJECT-TYPE
SYNTAX EthernetPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table EthernetPriorityTable"
INDEX { ethernetPriorityTableIndex }
::= { ethernetPriorityTable 1 }
L2CPPriorityTableEntry ::=
SEQUENCE { l2CPPriorityTableIndex INTEGER
, l2CPPriorityQueueMapping INTEGER
}
l2CPPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2CPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by L2CP priority."
::= { ethernet 17 }
l2CPPriorityTableEntry OBJECT-TYPE
SYNTAX L2CPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table L2CPPriorityTable"
INDEX { l2CPPriorityTableIndex }
::= { l2CPPriorityTable 1 }
IPDSCPPriorityTableEntry ::=
SEQUENCE { iPDSCPPriorityTableIndex INTEGER
, iPDSCPPriorityQueueMapping INTEGER
}
iPDSCPPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority."
::= { ethernet 19 }
iPDSCPPriorityTableEntry OBJECT-TYPE
SYNTAX IPDSCPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table IPDSCPPriorityTable"
INDEX { iPDSCPPriorityTableIndex }
::= { iPDSCPPriorityTable 1 }
MPLSTCPriorityTableEntry ::=
SEQUENCE { mPLSTCPriorityTableIndex INTEGER
, mPLSTCPriorityQueueMapping INTEGER
}
mPLSTCPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority."
::= { ethernet 21 }
mPLSTCPriorityTableEntry OBJECT-TYPE
SYNTAX MPLSTCPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table MPLSTCPriorityTable"
INDEX { mPLSTCPriorityTableIndex }
::= { mPLSTCPriorityTable 1 }
TdmTableEntry ::=
SEQUENCE { tdmTableIndex INTEGER
, tDMChannelStatus INTEGER
, tDMChannelLineCode INTEGER
, tDMChannelCableLength INTEGER
, tDMChannelLoopback INTEGER
}
tdmTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A table storing a configuration and status for each TDM channel"
::= { tDM 5 }
tdmTableEntry OBJECT-TYPE
SYNTAX TdmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table TdmTable"
INDEX { tdmTableIndex }
::= { tdmTable 1 }
LicenseRegulatoryBandsTableEntry ::=
SEQUENCE { licenseRegulatoryBandsTableIndex INTEGER
, licenseRegulatoryBandsList INTEGER
}
licenseRegulatoryBandsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LicenseRegulatoryBandsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { license 18 }
licenseRegulatoryBandsTableEntry OBJECT-TYPE
SYNTAX LicenseRegulatoryBandsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table LicenseRegulatoryBandsTable"
INDEX { licenseRegulatoryBandsTableIndex }
::= { licenseRegulatoryBandsTable 1 }
SNMPTrapTableEntry ::=
SEQUENCE { sNMPTrapTableIndex INTEGER
, sNMPTrapPortNumber INTEGER
, sNMPTrapInternetAddressType INTEGER
, sNMPTrapInternetAddress InetAddress
, sNMPTrapReceiverEnabled INTEGER
}
sNMPTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" SNMP trap configuration table."
::= { snmpControl 4 }
sNMPTrapTableEntry OBJECT-TYPE
SYNTAX SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNMPTrapTable"
INDEX { sNMPTrapTableIndex }
::= { sNMPTrapTable 1 }
SNTPServerTableEntry ::=
SEQUENCE { sNTPServerTableIndex INTEGER
, sNTPServerPortNumber INTEGER
, sNTPServerStatus DisplayString
, sNTPServerInternetAddressType INTEGER
, sNTPServerInternetAddress InetAddress
}
sNTPServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNTPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sntp 15 }
sNTPServerTableEntry OBJECT-TYPE
SYNTAX SNTPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNTPServerTable"
INDEX { sNTPServerTableIndex }
::= { sNTPServerTable 1 }
UserTableEntry ::=
SEQUENCE { userTableIndex INTEGER
, userName DisplayString
, userRole INTEGER
, userEnabled INTEGER
, userPassword DisplayString
}
userTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The User Table Control group contains objects specifically for user account management."
::= { aAAControl 2 }
userTableEntry OBJECT-TYPE
SYNTAX UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table UserTable"
INDEX { userTableIndex }
::= { userTable 1 }
CableDiagnosticsResultTableEntry ::=
SEQUENCE { cableDiagnosticsResultTableIndex INTEGER
, cableDiagnosticsResultsDateTime Integer32
, cableDiagPair1Results INTEGER
, cableDiagPair1Distance Integer32
, cableDiagPair2Results INTEGER
, cableDiagPair2Distance Integer32
, cableDiagPair3Results INTEGER
, cableDiagPair3Distance Integer32
, cableDiagPair4Results INTEGER
, cableDiagPair4Distance Integer32
}
cableDiagnosticsResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF CableDiagnosticsResultTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { cableDiagnostics 5 }
cableDiagnosticsResultTableEntry OBJECT-TYPE
SYNTAX CableDiagnosticsResultTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table CableDiagnosticsResultTable"
INDEX { cableDiagnosticsResultTableIndex }
::= { cableDiagnosticsResultTable 1 }
-- Dfs group attribute definitions
--
dfsTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the dfsTable"
::= { dfs 1 }
extendedSpectrumScanning OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables Extended Spectrum Scanning"
::= { dfs 3 }
-- DfsTable group attribute definitions
--
dfsTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the dfsTable."
::= { dfsTableEntry 1 }
dfsMeans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS means"
::= { dfsTableEntry 2 }
dfsNineNinePointNinePercentiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS 99.9 percentiles"
::= { dfsTableEntry 3 }
dfsPeaks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS peaks"
::= { dfsTableEntry 4 }
-- Bridge group attribute definitions
--
localPacketFiltering OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Local Packet Filtering is Enabled, the unit keeps
track of the port (Main, SFP, Aux or Wireless) on which a
packet with a given MAC source address destined to the
management agent has been received. This MAC address to
port mapping is then used in order to route any response
from the management agent to the right port. When Local
Packet Filtering is Disabled, any Ethernet packet from
the management agent is sent to all ports."
::= { bridge 1 }
-- Configuration group attribute definitions
--
iPv4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet protocol (IPv4) address. This address is used
by the family of Internet protocols to uniquely identify
the unit on a network."
::= { configuration 1 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A subnet allows the flow of network traffic between
hosts to be segregated based on a network configuration.
By organizing hosts into logical groups, subnetting can
improve network security and performance."
::= { configuration 2 }
gatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 address of a device on the current network that
acts as an IPv4 network gateway. A gateway acts as an
entrance / exit to packets from / to other networks"
::= { configuration 3 }
targetMACAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the PTP wireless unit forming the other
end of the PTP link"
::= { configuration 4 }
masterSlaveMode OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PTP wireless link operates using a master and slave
relationship"
::= { configuration 5 }
maximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-15..30)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the wireless unit is permitted to
use when establishing and maintaining the wireless link.
This may be reduced during installation"
::= { configuration 6 }
antennaGain OBJECT-TYPE
SYNTAX INTEGER (130..610)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Antenna Gain. Expressed in 10ths of dBi."
::= { configuration 7 }
cableLoss OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loss in the cable between the ODU and the antenna.
Expressed in 10ths of dB. NB: This attribute is ignored
for variants with an integral antenna."
::= { configuration 8 }
eIRP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Effective Isotropic Radiated Power (EIRP) describes the
strength of the radio signal leaving the wireless unit.
Expressed in 10ths of dBm"
::= { configuration 9 }
channelBandwidth OBJECT-TYPE
SYNTAX INTEGER {
bw30MHz(0),
bw15MHz(1),
bw10MHz(2),
bw5MHz(3),
bw20MHz(4),
bw56MHz(5),
bw50MHz(6),
bw40MHz(7),
bw45MHz(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This control sets the bandwidth of the transmit and
receive radio channels"
::= { configuration 11 }
linkName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the PTP link allocated by the System
Administrator. Used to establish a connection with the
correct PTP wireless unit at the other end of the link.
NOTE: The link name MUST be the same at both ends of the
PTP link."
::= { configuration 14 }
siteName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field contains a user-provided description of the
site name together with any additional notes"
::= { configuration 15 }
accessMethod OBJECT-TYPE
SYNTAX INTEGER {
linkAccess(0),
linkNameAccess(1),
groupAccess(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODUs must be configured in pairs before a link can be
established. The Access Method attribute determines how
the paired ODUs will recognise each other. For the Link
Access method, each ODU must be configured with Target
MAC Address equal to the MAC Address of the other unit.
For the Link Name Access method, both units must be
configured with the same Link Name. For the Group Access
method, both units must be configured with the same Group
ID."
::= { configuration 16 }
groupID OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Access Method is set to Group Access, the Group ID
identifies all the units belonging to the same group"
::= { configuration 17 }
iPv6Address OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet protocol (IPv6) address. This address is used
by the family of Internet protocols to uniquely identify
the unit on a network."
::= { configuration 18 }
iPVersion OBJECT-TYPE
SYNTAX INTEGER {
iPv4(0),
iPv6(1),
dualIPv4andIPv6(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP protocol selection. Choice of IPv4, IPv6 or Dual."
::= { configuration 20 }
iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auto configured link local IPv6 address"
::= { configuration 21 }
iPv6PrefixLength OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv6 prefix length"
::= { configuration 22 }
iPv6GatewayAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address of a device on the current network that
is currently acting as an IPv6 network gateway. A gateway
acts as an entrance / exit to packets from / to other
networks."
::= { configuration 23 }
remoteInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
remoteInternetAddressType."
::= { configuration 24 }
remoteInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"INET address used to identify the peer wireless unit"
::= { configuration 25 }
subbandLowestFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lowest center frequency of the subset of channels."
::= { configuration 26 }
subbandHighestFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Highest center frequency of the subset of channels."
::= { configuration 27 }
enableTransmission OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
muted(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control for enabling/disabling the radio transmitter of
the Master. Note: Use Web Properties to control this
feature."
::= { configuration 28 }
-- Ethernet group attribute definitions
--
mainPSUPortAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls whether the local Ethernet interface
configuration is automatically negotiated or forced. Do
not use a forced setting together with auto negotiation
at the Ethernet link partner. If you want to run your
Ethernet link at a fixed speed and duplex then you would
normally leave auto negotiation enabled and only enable
the single Auto Neg Advertisement option that you want
the link to run in - FORCING ETHERNET CONFIGURATION IS A
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
new setting will only take effect after a system reboot."
::= { ethernet 1 }
mainPSUPortAutoNegAdvertisement OBJECT-TYPE
SYNTAX BITS {
negInvalid(2),
neg10MbpsHalfDuplex(3),
neg10MbpsFullDuplex(4),
neg100MbpsHalfDuplex(5),
neg100MbpsFullDuplex(6),
neg1000MbpsFullDuplex(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This sets the different Ethernet configurations that
will be advertised during auto negotiation. Note the new
setting will only take effect after a system reboot.
WARNING: Duplex mismatch may result if both ends of the
Ethernet link do not have the same settings. Do not auto
negotiation together with a fixed setting at the Ethernet
link partner. WARNING: Make sure that you select
option(s) that you know your connected equipment can
cater for!"
::= { ethernet 2 }
mainPSUPortAutoMdix OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This enables/disables the Auto MDI/MDIX capability. NB:
The new setting will only take effect after a system
reboot"
::= { ethernet 3 }
mainPSUPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1),
fiberLinkUp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the Main PSU Ethernet link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ethernet 4 }
mainPSUPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the Main PSU Ethernet
link"
::= { ethernet 5 }
dataPortWirelessDownAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, this causes the Ethernet link to be
dropped briefly when the wireless link drops. This is so
that spanning tree algorithms can quickly detect that
there is a problem."
::= { ethernet 6 }
useVLANForManagementInterfaces OBJECT-TYPE
SYNTAX INTEGER {
noVLANTagging(0),
iEEE8021QTaggedCTagType8100(1),
iEEE8021adTaggedSTagorBTagType88a8(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether the management interfaces
(WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 7 }
vLANManagementPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(0),
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN Priority (0-7) will be included in packets
generated by the management interfaces"
::= { ethernet 8 }
vLANManagementVID OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN VID (0-4094) will be included in packets
generated by the management interfaces. Note the new
setting will only take effect after a system reboot"
::= { ethernet 11 }
auxPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the Aux Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ethernet 12 }
auxPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the Aux Ethernet link"
::= { ethernet 13 }
ethernetPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the vLANPriorityTable."
::= { ethernet 14 }
l2CPPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the l2CPPriorityTable."
::= { ethernet 16 }
iPDSCPPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the iPDSCPPriorityTable."
::= { ethernet 18 }
mPLSTCPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the mPLSTCPriorityTable."
::= { ethernet 20 }
managementPortWirelessDownAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, this causes the management link to be
dropped briefly when the wireless link drops. This is so
that spanning tree algorithms can quickly detect that
there is a problem."
::= { ethernet 23 }
qOSPriorityScheme OBJECT-TYPE
SYNTAX INTEGER {
ethernet(0),
iPMPLS(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects classification based on fields in the Ethernet
header (Layer 2) or in the Network header (Layer 3). The
unit recognises two network layer protocols: IP and MPLS"
::= { ethernet 24 }
unknownNetworkPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of unknown network
protocols to an egress queue at the wireless port.
Unknown means something other than IP and MPLS"
::= { ethernet 25 }
dSCPManagementPriority OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This Differentiated Services Code Point value will be
inserted in the IP Header of all IP Datagrams transmitted
by the management interfaces"
::= { ethernet 26 }
dataBridgingStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of Ethernet Data traffic bridging over
the wireless link"
::= { ethernet 27 }
mainPSUPortAllocation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
dataOnly(1),
dataandInBandManagement(2),
outofBandLocalManagement(3),
outofBandRemoteManagement(4),
secondDataOnly(5),
secondDataandInBandManagement(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the service or services supported by the Main
PSU Ethernet port"
::= { ethernet 28 }
auxPortAllocation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
dataOnly(1),
dataandInBandManagement(2),
outofBandLocalManagement(3),
outofBandRemoteManagement(4),
secondDataOnly(5),
secondDataandInBandManagement(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the service or services supported by the Aux
Ethernet port"
::= { ethernet 29 }
sFPPortAllocation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
dataOnly(1),
dataandInBandManagement(2),
outofBandLocalManagement(3),
outofBandRemoteManagement(4),
secondDataOnly(5),
secondDataandInBandManagement(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the service or services supported by the SFP
Ethernet port"
::= { ethernet 30 }
dataPortPauseFrames OBJECT-TYPE
SYNTAX INTEGER {
tunnel(0),
discard(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Controls whether the bridge tunnels or discards Layer 2
PAUSE frames arriving at the Data Port. Such frames are
identified by the destination MAC Address being equal to
01-80-C2-00-00-01"
::= { ethernet 31 }
sFPPortAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls whether the local SFP Ethernet interface
configuration is automatically negotiated or forced. Do
not use a forced setting together with auto negotiation
at the Ethernet link partner. If you want to run your
Ethernet link at a fixed speed and duplex then you would
normally leave auto negotiation enabled and only enable
the single Auto Neg Advertisement option that you want
the link to run in - FORCING ETHERNET CONFIGURATION IS A
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
new setting will only take effect after a system reboot."
::= { ethernet 32 }
sFPPortAutoNegAdvertisement OBJECT-TYPE
SYNTAX BITS {
negInvalid(2),
neg10MbpsHalfDuplex(3),
neg10MbpsFullDuplex(4),
neg100MbpsHalfDuplex(5),
neg100MbpsFullDuplex(6),
neg1000MbpsFullDuplex(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This sets the different SFP Ethernet configurations that
will be advertised during auto negotiation. Note the new
setting will only take effect after a system reboot.
WARNING: Duplex mismatch may result if both ends of the
Ethernet link do not have the same settings. Do not auto
negotiation together with a fixed setting at the Ethernet
link partner. WARNING: Make sure that you select
option(s) that you know your connected equipment can
cater for!"
::= { ethernet 33 }
sFPPortAutoMdix OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This enables/disables the Auto MDI/MDIX capability. NB:
The new setting will only take effect after a system
reboot"
::= { ethernet 34 }
sFPPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1),
fiberLinkUp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the SFP Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ethernet 35 }
sFPPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the SFP Ethernet link"
::= { ethernet 36 }
auxPortPowerOverEthernetOutput OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the Power Over Ethernet (PoE) output of the
Aux port. Enabling PoE output may lead to system
instability; please refer to the User Guide before
enabling this control"
::= { ethernet 37 }
auxPortPowerOverEthernetOutputStatus OBJECT-TYPE
SYNTAX INTEGER {
poEOutputOn(0),
poEOutputDisabled(1),
poEOutputEnabledbutNotActiveErrororNoLoadPresent(2),
poEOutputOverloadError(3),
poEOutputOverTempError(4),
poEOutputErrorDetected(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the Power Over Ethernet (PoE) output
of the Aux port"
::= { ethernet 38 }
syncETracking OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1),
internalTDMUseOnly(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether Synchronous Ethernet (SyncE) network
synchronization is enabled."
::= { ethernet 39 }
syncEEquipmentClock OBJECT-TYPE
SYNTAX INTEGER {
eECOption1(0),
eECOption2(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"EEC-Option 1 applies to synchronous Ethernet equipments
that are designed to interwork with networks optimized
for the 2048-kbit/s hierarchy. Corresponds to ITU-T G.813
Option 1; EEC-Option 2 applies to synchronous Ethernet
equipments that are designed to interwork with networks
optimized for the 1544-kbit/s hierarchy. Corresponds to
Type IV clock from ITU-T G.812."
::= { ethernet 40 }
mainPSUPortQLRxOverwrite OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Override for the Synchronous Ethernet (SyncE) received
Quality Level (QL) on the main PSU port."
::= { ethernet 41 }
mainPSUPortSSMTx OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the Synchronous Ethernet (SyncE)
Quality Level (QL) is transmitted on the Main PSU port"
::= { ethernet 42 }
sFPPortSSMTx OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the Synchronous Ethernet (SyncE)
Quality Level (QL) is transmitted on the SFP port"
::= { ethernet 43 }
auxPortSSMTx OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the Synchronous Ethernet (SyncE)
Quality Level (QL) is transmitted on the Aux port"
::= { ethernet 44 }
syncETrackingState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
acquiringWirelessLock(1),
freeRunning(2),
lockedLocalAcquiringHoldover(3),
lockedLocalHoldoverAcquired(4),
holdover(5),
lockedRemoteAcquiringHoldover(6),
lockedRemoteHoldoverAcquired(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of Synchronous Ethernet (SyncE)
network synchronization."
::= { ethernet 45 }
mainPSUPortQLRx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12),
qLFAILED(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Quality Level (QL)
currently being received on the main PSU port."
::= { ethernet 46 }
auxPortQLRx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12),
qLFAILED(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Quality Level (QL)
currently being received on the auxiliary port."
::= { ethernet 47 }
sFPPortQLRx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12),
qLFAILED(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Quality Level (QL)
currently being received on the SFP port."
::= { ethernet 48 }
mainPSUPortQLTx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) transmit Quality Level
(QL) of the main PSU port."
::= { ethernet 49 }
auxPortQLTx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) transmit Quality Level
(QL) of the auxiliary port."
::= { ethernet 50 }
sFPPortQLTx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) transmit Quality Level
(QL) of the SFP port."
::= { ethernet 51 }
mainPSUPortSyncEMasterSlaveStatus OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main PSU port Synchronous Ethernet (SyncE)
Master/Slave status"
::= { ethernet 52 }
auxPortSyncEMasterSlaveStatus OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary port Synchronous Ethernet (SyncE)
Master/Slave status"
::= { ethernet 53 }
sFPPortSyncEMasterSlaveStatus OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFP port Synchronous Ethernet (SyncE) Master/Slave
status"
::= { ethernet 54 }
mainPSUPortGigabitMasterSlaveStatus OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1),
notApplicable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main PSU port Gigabit Ethernet Master/Slave status"
::= { ethernet 55 }
auxPortGigabitMasterSlaveStatus OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1),
notApplicable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary port Gigabit Ethernet Master/Slave status"
::= { ethernet 56 }
sFPPortGigabitMasterSlaveStatus OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1),
notApplicable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFP port Gigabit Ethernet Master/Slave status"
::= { ethernet 57 }
transparentClock OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This control enables the Precision Time Protocol
(IEEE-1588) Transparent Clock. Once enabled the unit will
modify the correction field in PTP event messages to take
account of the time these frames have been resident in
this system. This will happen for all PTP frames at Layer
2 & Layer 3 (IPv4 & IPv6) unless a transparent clock VLAN
is enabled."
::= { ethernet 58 }
transparentClockVLAN OBJECT-TYPE
SYNTAX INTEGER {
all(0),
sTagged(1),
cTagged(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If All is selected then all PTP frames will have their
correction fields modified with the residence time. If an
S-TAG or C-TAG is selected, only frames with this VLAN
tag and matching the VLAN ID in the Transparent Clock VID
will have their correction fields modified."
::= { ethernet 59 }
transparentClockVID OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VLAN ID which frames must match if they are to be
corrected. Only valid when an S-TAG or C-TAG has been
selected."
::= { ethernet 60 }
mainPSUPortAcceptedQLRx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12),
qLFAILED(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Quality Level (QL)
currently accepted (validated) on the main PSU port."
::= { ethernet 61 }
auxPortAcceptedQLRx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12),
qLFAILED(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Quality Level (QL)
currently accepted (validated) on the auxiliary port."
::= { ethernet 62 }
sFPPortAcceptedQLRx OBJECT-TYPE
SYNTAX INTEGER {
none(0),
qLPRS(1),
qLSTU(2),
qLPRC(3),
qLST2(4),
qLSSUAQLTNC(5),
qLSSUB(6),
qLST3E(7),
qLEEC2QLST3(8),
qLEEC1QLSEC(9),
qLSMC(10),
qLPROV(11),
qLDNUQLDUS(12),
qLFAILED(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Quality Level (QL)
currently accepted (validated) on the SFP port."
::= { ethernet 63 }
mainPSUPortSyncERxStatus OBJECT-TYPE
SYNTAX INTEGER {
good(0),
waittoRestore(1),
failed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Receive Status of the
main PSU port"
::= { ethernet 64 }
auxPortSyncERxStatus OBJECT-TYPE
SYNTAX INTEGER {
good(0),
waittoRestore(1),
failed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Receive Status of the
auxiliary port"
::= { ethernet 65 }
sFPPortSyncERxStatus OBJECT-TYPE
SYNTAX INTEGER {
good(0),
waittoRestore(1),
failed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Synchronous Ethernet (SyncE) Receive Status of the
SFP port"
::= { ethernet 66 }
nIDULanPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1),
fiberLinkUp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the NIDU LAN Ethernet link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ethernet 67 }
nIDULanPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the Ethernet link to the
NIDU LAN Port"
::= { ethernet 68 }
oOBPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of traffic to an egress
queue at the wireless port"
::= { ethernet 69 }
nIDULanPortAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls whether the local Ethernet interface
configuration is automatically negotiated or forced. Do
not use a forced setting together with auto negotiation
at the Ethernet link partner. If you want to run your
Ethernet link at a fixed speed and duplex then you would
normally leave auto negotiation enabled and only enable
the single Auto Neg Advertisement option that you want
the link to run in - FORCING ETHERNET CONFIGURATION IS A
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
new setting will only take effect after a system reboot."
::= { ethernet 70 }
nIDULanPortAutoNegAdvertisement OBJECT-TYPE
SYNTAX BITS {
negInvalid(2),
neg10MbpsHalfDuplex(3),
neg10MbpsFullDuplex(4),
neg100MbpsHalfDuplex(5),
neg100MbpsFullDuplex(6),
neg1000MbpsFullDuplex(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This sets the different Ethernet configurations that
will be advertised during auto negotiation. Note the new
setting will only take effect after a system reboot.
WARNING: Duplex mismatch may result if both ends of the
Ethernet link do not have the same settings. Do not auto
negotiation together with a fixed setting at the Ethernet
link partner. WARNING: Make sure that you select
option(s) that you know your connected equipment can
cater for!"
::= { ethernet 71 }
nIDULanPortAutoMdix OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This enables/disables the Auto MDI/MDIX capability. NB:
The new setting will only take effect after a system
reboot"
::= { ethernet 72 }
nIDULanPortGigabitMasterSlaveStatus OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1),
notApplicable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The NIDU LAN port Gigabit Ethernet Master/Slave status"
::= { ethernet 73 }
txMABFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of MAB frames transmitted"
::= { ethernet 74 }
managementNetworkAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled the local Out-of-Band interface can be used
to access the remote management network. If not enabled
the local management agent can still be accessed from the
remote management network and the local Out-of-Band
interface"
::= { ethernet 75 }
secondDataPortPauseFrames OBJECT-TYPE
SYNTAX INTEGER {
tunnel(0),
discard(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Controls whether the bridge tunnels or discards Layer 2
PAUSE frames arriving at the Second Data Service Port.
Such frames are identified by the destination MAC Address
being equal to 01-80-C2-00-00-01"
::= { ethernet 76 }
secondDataBridgingStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of bridging Second Data Service Ethernet
traffic over the wireless link"
::= { ethernet 80 }
transparentClockPort OBJECT-TYPE
SYNTAX INTEGER {
mainPSU(0),
aux(1),
sFP(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IEEE 1588 Transparent Clock source"
::= { ethernet 81 }
-- EthernetPriorityTable group attribute definitions
--
ethernetPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8),
untagged(9)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet priority flag, used to index values in the
ethernetPriorityTable"
::= { ethernetPriorityTableEntry 1 }
ethernetPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this Ethernet priority
(also known as IEEE 802.1p value) to an egress queue at
the wireless port"
::= { ethernetPriorityTableEntry 2 }
-- L2CPPriorityTable group attribute definitions
--
l2CPPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER {
bridge(1),
mRP(2),
cFM(3),
rAPS(4),
eAPS(5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"L2CP priority flag, used to index values in the
l2CPPriorityTable"
::= { l2CPPriorityTableEntry 1 }
l2CPPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this layer two control
protocol (L2CP) to an egress queue at the wireless port"
::= { l2CPPriorityTableEntry 2 }
-- IPDSCPPriorityTable group attribute definitions
--
iPDSCPPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IP DSCP priority flag, used to index values in the
iPDSCPPriorityTable"
::= { iPDSCPPriorityTableEntry 1 }
iPDSCPPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this IP differentiated
services code point (DSCP) value to an egress queue at
the wireless port"
::= { iPDSCPPriorityTableEntry 2 }
-- MPLSTCPriorityTable group attribute definitions
--
mPLSTCPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MPLS TC priority flag, used to index values in the
mPLSTCPriorityTable"
::= { mPLSTCPriorityTableEntry 1 }
mPLSTCPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this MPLS traffic class
(the field formerly known as EXP) to an egress queue at
the wireless port"
::= { mPLSTCPriorityTableEntry 2 }
-- TDM group attribute definitions
--
tDMInterfaceControl OBJECT-TYPE
SYNTAX INTEGER {
none(0),
e1(1),
t1(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line interface type. If this is set to 'None' then
the TDM interfaces are disabled, and the TDM settings
will be ignored."
::= { tDM 1 }
tDMInterfaceStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
connectedNotConfigured(1),
notConnected(2),
nIDUdetectedonAUXport(3),
error(4),
codeDownloadInProgress(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"@Current status of the connection to the TDM Box. A
state of 'Up' on a green background indicates that the
TDM Box is connected OK. When connecting a TDM Box only
the Main Ethernet port should be used"
::= { tDM 2 }
tDMEnabledChannels OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of TDM channels enabled in the system"
::= { tDM 3 }
tdmTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the TdmTable"
::= { tDM 4 }
tDMConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
linetypemismatch(1),
enabledchannelsmismatch(2),
linetypeandenabledchannelsmismatch(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the configuration of the TDM Box. A
state of 'Ok' on a green background indicates that the
TDM Box configuration is matched OK with the remote end."
::= { tDM 6 }
lowestTDMModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest modulation mode at which tdm data will be
sent. The effective lowest modulation mode is displayed
in the TDM Configuration page"
::= { tDM 7 }
-- TdmTable group attribute definitions
--
tdmTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"TDM Channel flag, used to index channels in the
TdmTable"
::= { tdmTableEntry 1 }
tDMChannelStatus OBJECT-TYPE
SYNTAX INTEGER {
up(0),
noSignalLocal(1),
noSignalRemote(2),
noSignalLocalandRemote(3),
remoteTiming(4),
noSignalLocalandRemoteTiming(5),
disabled(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the TDM channels. A value of 0
indicates that a TDM channel is established"
::= { tdmTableEntry 2 }
tDMChannelLineCode OBJECT-TYPE
SYNTAX INTEGER {
aMI(0),
b8ZSorHDB3(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line code setting of the TDM interfaces. This must
match the setting of the device connected to an
interface"
::= { tdmTableEntry 3 }
tDMChannelCableLength OBJECT-TYPE
SYNTAX INTEGER {
feet133(0),
feet266(1),
feet399(2),
feet533(3),
feet655(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lengths of the cables connected to the TDM
interfaces, measured in feet"
::= { tdmTableEntry 4 }
tDMChannelLoopback OBJECT-TYPE
SYNTAX INTEGER {
none(0),
copper(1),
wireless(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loopback status of TDM channels. This is intended
for installation testing and should be set to 'None' for
normal operation. The wire connections to a unit can be
tested by applying a 'Copper' loopback to the local unit.
The wireless connection to the remote unit can be tested
by applying a 'Wireless' loopback to the remote unit with
no loopback on the local unit. NB: a change of state may
generate an SNMP trap and/or SMTP email alert"
::= { tdmTableEntry 5 }
-- License group attribute definitions
--
regulatoryBand OBJECT-TYPE
SYNTAX INTEGER {
regInvalid(0),
reg158GHz(1),
reg258GHz(2),
reg358GHz(3),
reg458GHz(4),
reg558GHz(5),
reg658GHz(6),
reg754GHzUnrestrictedEIRPwithDFS(7),
reg854GHzUnrestrictedEIRP(8),
reg9(9),
reg1058GHz(10),
reg1158GHz(11),
reg1254GHzFCCUNII2C(12),
reg1354GHz(13),
reg1449GHzPublicSafety(14),
reg15(15),
reg1659GHz(16),
reg1759GHz(17),
reg1849GHzPublicSafety(18),
reg1958GHz(19),
reg2054GHz(20),
reg2154GHz(21),
reg2258GHz(22),
reg23(23),
reg2458GHz(24),
reg2558GHzETSI(25),
reg2654GHzETSI(26),
reg2758GHz(27),
reg2858GHz(28),
reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29),
reg3054GHz(30),
reg3158GHz(31),
reg3249GHzLicensed(32),
reg3349GHzETSIBroadbandDisasterRelief(33),
reg3458GHz(34),
reg3558GHzUnrestrictedEIRP(35),
reg3654GHz(36),
reg3758GHz(37),
reg3852GHzFCCUNII2A(38),
reg3951GHzETSIBroadbandDisasterRelief(39),
reg4054GHz(40),
reg4154GHz(41),
reg4254GHz(42),
reg4354GHz(43),
reg4458GHz(44),
reg4558GHz(45),
reg4658GHz(46),
reg4758GHz(47),
reg4858GHz(48),
reg4958GHz(49),
reg5058GHz(50),
reg5158GHz(51),
reg5258GHz(52),
reg5358GHz(53),
reg5458GHz(54),
reg5558GHz(55),
reg5654GHz(56),
reg5754GHz(57),
reg5858GHz(58),
reg5958GHz(59),
reg6058GHz(60),
reg6149GHz(61),
reg6252GHz(62),
reg6352GHz(63),
reg6451GHz(64),
reg6551GHz(65),
reg6651GHz(66),
reg6752GHz(67),
reg6852GHz(68),
reg6952GHz(69),
reg7052GHz(70),
reg7152GHz(71),
reg7252GHz(72),
reg7352GHz(73),
reg7452GHz(74),
reg7552GHz(75),
reg7652GHz(76),
reg7752GHz(77),
reg7849GHz(78),
reg7954GHz(79),
reg8049GHz(80),
reg8147GHz(81),
reg8247GHz(82),
reg8352GHz(83),
reg8451GHzFCCUNII1(84),
reg8552GHzFCCUNII12A(85),
reg8654GHzFCCUNII2A2C(86),
reg8758GHz(87),
reg8849GHz(88),
reg8949GHz(89),
reg9054GHzFCCUNII2CParabolicantenna(90),
reg9152GHzFCCUNII2AParabolicantenna(91),
reg9251GHzFCCUNII1Parabolicantenna(92),
reg9349GHz(93),
reg94(94),
reg95(95),
reg96(96),
reg97(97),
reg98(98),
reg99(99),
reg100(100),
reg101(101),
reg102(102),
reg103(103),
reg104(104),
reg105(105),
reg106(106),
reg107(107),
reg108(108),
reg109(109),
reg110(110),
reg111(111),
reg112(112),
reg113(113),
reg114(114),
reg115(115),
reg116(116),
reg117(117),
reg118(118),
reg119(119),
reg120(120),
reg121(121),
reg122(122),
reg123(123),
reg124(124),
reg125(125),
reg126(126),
reg127(127),
reg128(128),
reg129(129),
reg130(130),
reg131(131),
reg132(132),
reg133(133),
reg134(134),
reg135(135),
reg136(136),
reg137(137),
reg138(138),
reg139(139),
reg140(140),
reg141(141),
reg142(142),
reg143(143),
reg144(144),
reg145(145),
reg146(146),
reg147(147),
reg148(148),
reg149(149),
reg150(150),
reg151(151),
reg152(152),
reg153(153),
reg154(154),
reg155(155),
reg156(156),
reg157(157),
reg158(158),
reg159(159),
reg160(160),
reg161(161),
reg162(162),
reg163(163),
reg164(164),
reg165(165),
reg166(166),
reg167(167),
reg168(168),
reg169(169),
reg170(170),
reg171(171),
reg172(172),
reg173(173),
reg174(174),
reg175(175),
reg176(176),
reg177(177),
reg178(178),
reg179(179),
reg180(180),
reg181(181),
reg182(182),
reg183(183),
reg184(184),
reg185(185),
reg186(186),
reg187(187),
reg188(188),
reg189(189),
reg190(190),
reg191(191),
reg192(192),
reg193(193),
reg194(194),
reg195(195),
reg196(196),
reg197(197),
reg198(198),
reg199(199),
reg200(200),
reg201(201),
reg202(202),
reg203(203),
reg204(204),
reg205(205),
reg206(206),
reg207(207),
reg208(208),
reg209(209),
reg210(210),
reg211(211),
reg212(212),
reg213(213),
reg214(214),
reg215(215),
reg216(216),
reg217(217),
reg218(218),
reg219(219),
reg220(220),
reg221(221),
reg222(222),
reg223(223),
reg224(224),
reg225(225),
reg226(226),
reg227(227),
reg228(228),
reg229(229),
reg230(230),
reg231(231),
reg232(232),
reg233(233),
reg234(234),
reg235(235),
reg236(236),
reg237(237),
reg238(238),
reg239(239),
reg240(240),
reg241(241),
reg242(242),
reg243(243),
reg244(244),
reg245(245),
reg246(246),
reg247(247),
reg248(248),
reg249(249),
reg250(250),
reg251(251),
reg252(252),
reg253(253),
reg254(254),
reg255(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Regulatory Band prohibits the wireless unit from
operating outside the regulated limits. An invalid
Regulatory Band may be caused by a missing or incorrect
License Key, a corrupt MAC Address or an attempt to
configure a Regulatory Band not allowed by the License
Key. NB: a change of state may generate an SNMP trap
and/or SMTP email alert."
::= { license 1 }
productVariant OBJECT-TYPE
SYNTAX INTEGER {
pTPxx400Full(0),
pTPxx400Deprecated1(1),
pTPxx400Deprecated2(2),
pTPxx400Lite(3),
spare1(4),
pTPxx300(5),
spare2(6),
spare3(7),
pTPxx500FullDeprecated(8),
pTPxx500LiteDeprecated(9),
pTPxx500(10),
pTPxx600Lite(11),
pTPxx600Full(12),
pTPxx650(13),
spare6(14),
pTP800(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product variant"
::= { license 2 }
productName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the product variant"
::= { license 3 }
frequencyVariant OBJECT-TYPE
SYNTAX INTEGER {
freq5GHz(0),
freq4GHz(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware frequency variant"
::= { license 5 }
sNMPv3Enable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMPv3 availability control"
::= { license 9 }
licenseVersion OBJECT-TYPE
SYNTAX INTEGER (1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key version."
::= { license 12 }
licenseUnitSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..11))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit serial number."
::= { license 13 }
licenseIssueNumber OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key issue number for this unit."
::= { license 15 }
licenseCountry OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..103))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The country in which this unit is licensed to operate."
::= { license 16 }
licenseNumberOfRegulatoryBands OBJECT-TYPE
SYNTAX INTEGER (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of regulatory bands for which the unit is
licensed to operate."
::= { license 17 }
licenseBandwidthCap OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless link bandwidth cap in MHz. Zero indicates
no bandwidth cap."
::= { license 20 }
licenseEncryption OBJECT-TYPE
SYNTAX INTEGER {
none(0),
aESRijndael(1),
aES192bitRijndael(2),
aES256bitRijndael(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key encryption algorithms available."
::= { license 21 }
licenseSecurityLevel OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
fIPS(1),
uCAPL(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key security level."
::= { license 22 }
licenseGroupAccess OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key group access setting."
::= { license 23 }
licenseOOBManagementSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key Out-Of-Band (OOB) support setting."
::= { license 24 }
licenseSFPPortSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key Ethernet SFP Port support setting."
::= { license 25 }
licenseAuxiliaryPortSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key Ethernet Auxiliary Port support
setting."
::= { license 26 }
licenseCapacity OBJECT-TYPE
SYNTAX INTEGER {
full(0),
mid(1),
lite(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key capacity"
::= { license 27 }
licenseMaxNumberOfTDMChannels OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key maximum TDM channels setting. Zero
indicates TDM not available."
::= { license 28 }
licenseIEEE1588Support OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key IEEE-1588 support setting."
::= { license 29 }
licenseSyncESupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key SyncE support setting."
::= { license 30 }
licenseIPv6Support OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key IPv6 support setting."
::= { license 31 }
licenseMinimumFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..23))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum firmware version required to support this
license key."
::= { license 32 }
licenseFullCapabilityTrialStatus OBJECT-TYPE
SYNTAX INTEGER {
available(0),
active(1),
inactive(2),
expired(3),
unavailable(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key full capability trial period status."
::= { license 33 }
licenseRemainingTrialPeriod OBJECT-TYPE
SYNTAX INTEGER (0..31536000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remaining time for the license key full capability
trial period."
::= { license 34 }
licenseRemainingTrialPeriodAlarm OBJECT-TYPE
SYNTAX INTEGER {
fullCapabilityTrialNotActiveOrMoreThan7DaysRemaining(0),
fullCapabilityTrialExpiringInLessThan7Days(1),
fullCapabilityTrialExpiringInLessThan6Days(2),
fullCapabilityTrialExpiringInLessThan5Days(3),
fullCapabilityTrialExpiringInLessThan4Days(4),
fullCapabilityTrialExpiringInLessThan3Days(5),
fullCapabilityTrialExpiringInLessThan2Days(6),
fullCapabilityTrialExpiringInLessThan1Day(7),
fullCapabilityTrialHasExpired(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the full capability trial license period is about to
expire then purchase a license upgrade from your
reseller."
::= { license 35 }
capacityVariantMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote node of this link has a lower link capacity.
Operating with a reduced effective link capacity."
::= { license 36 }
licenseTDDSyncSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key TDD Synchronization support setting."
::= { license 37 }
licenseMaxLinkRange OBJECT-TYPE
SYNTAX INTEGER (0..1999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum licensed range for the wireless link in tenths
of km. A value of zero indicates that the maximum link
range is not limited by the license."
::= { license 38 }
licenseTrialPeriod OBJECT-TYPE
SYNTAX INTEGER (0..365)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key maximum trial period, in days."
::= { license 39 }
licenseRARSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
mAB(1),
dLEP(2),
mABandDLEP(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The license key Radio Aware Routing support setting."
::= { license 40 }
-- LicenseRegulatoryBandsTable group attribute definitions
--
licenseRegulatoryBandsTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"License regulatory bands, used to index the
LicenseRegulatoryBandsTable."
::= { licenseRegulatoryBandsTableEntry 1 }
licenseRegulatoryBandsList OBJECT-TYPE
SYNTAX INTEGER {
regInvalid(0),
reg158GHz(1),
reg258GHz(2),
reg358GHz(3),
reg458GHz(4),
reg558GHz(5),
reg658GHz(6),
reg754GHzUnrestrictedEIRPwithDFS(7),
reg854GHzUnrestrictedEIRP(8),
reg9(9),
reg1058GHz(10),
reg1158GHz(11),
reg1254GHzFCCUNII2C(12),
reg1354GHz(13),
reg1449GHzPublicSafety(14),
reg15(15),
reg1659GHz(16),
reg1759GHz(17),
reg1849GHzPublicSafety(18),
reg1958GHz(19),
reg2054GHz(20),
reg2154GHz(21),
reg2258GHz(22),
reg23(23),
reg2458GHz(24),
reg2558GHzETSI(25),
reg2654GHzETSI(26),
reg2758GHz(27),
reg2858GHz(28),
reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29),
reg3054GHz(30),
reg3158GHz(31),
reg3249GHzLicensed(32),
reg3349GHzETSIBroadbandDisasterRelief(33),
reg3458GHz(34),
reg3558GHzUnrestrictedEIRP(35),
reg3654GHz(36),
reg3758GHz(37),
reg3852GHzFCCUNII2A(38),
reg3951GHzETSIBroadbandDisasterRelief(39),
reg4054GHz(40),
reg4154GHz(41),
reg4254GHz(42),
reg4354GHz(43),
reg4458GHz(44),
reg4558GHz(45),
reg4658GHz(46),
reg4758GHz(47),
reg4858GHz(48),
reg4958GHz(49),
reg5058GHz(50),
reg5158GHz(51),
reg5258GHz(52),
reg5358GHz(53),
reg5458GHz(54),
reg5558GHz(55),
reg5654GHz(56),
reg5754GHz(57),
reg5858GHz(58),
reg5958GHz(59),
reg6058GHz(60),
reg6149GHz(61),
reg6252GHz(62),
reg6352GHz(63),
reg6451GHz(64),
reg6551GHz(65),
reg6651GHz(66),
reg6752GHz(67),
reg6852GHz(68),
reg6952GHz(69),
reg7052GHz(70),
reg7152GHz(71),
reg7252GHz(72),
reg7352GHz(73),
reg7452GHz(74),
reg7552GHz(75),
reg7652GHz(76),
reg7752GHz(77),
reg7849GHz(78),
reg7954GHz(79),
reg8049GHz(80),
reg8147GHz(81),
reg8247GHz(82),
reg8352GHz(83),
reg8451GHzFCCUNII1(84),
reg8552GHzFCCUNII12A(85),
reg8654GHzFCCUNII2A2C(86),
reg8758GHz(87),
reg8849GHz(88),
reg8949GHz(89),
reg9054GHzFCCUNII2CParabolicantenna(90),
reg9152GHzFCCUNII2AParabolicantenna(91),
reg9251GHzFCCUNII1Parabolicantenna(92),
reg9349GHz(93),
reg94(94),
reg95(95),
reg96(96),
reg97(97),
reg98(98),
reg99(99),
reg100(100),
reg101(101),
reg102(102),
reg103(103),
reg104(104),
reg105(105),
reg106(106),
reg107(107),
reg108(108),
reg109(109),
reg110(110),
reg111(111),
reg112(112),
reg113(113),
reg114(114),
reg115(115),
reg116(116),
reg117(117),
reg118(118),
reg119(119),
reg120(120),
reg121(121),
reg122(122),
reg123(123),
reg124(124),
reg125(125),
reg126(126),
reg127(127),
reg128(128),
reg129(129),
reg130(130),
reg131(131),
reg132(132),
reg133(133),
reg134(134),
reg135(135),
reg136(136),
reg137(137),
reg138(138),
reg139(139),
reg140(140),
reg141(141),
reg142(142),
reg143(143),
reg144(144),
reg145(145),
reg146(146),
reg147(147),
reg148(148),
reg149(149),
reg150(150),
reg151(151),
reg152(152),
reg153(153),
reg154(154),
reg155(155),
reg156(156),
reg157(157),
reg158(158),
reg159(159),
reg160(160),
reg161(161),
reg162(162),
reg163(163),
reg164(164),
reg165(165),
reg166(166),
reg167(167),
reg168(168),
reg169(169),
reg170(170),
reg171(171),
reg172(172),
reg173(173),
reg174(174),
reg175(175),
reg176(176),
reg177(177),
reg178(178),
reg179(179),
reg180(180),
reg181(181),
reg182(182),
reg183(183),
reg184(184),
reg185(185),
reg186(186),
reg187(187),
reg188(188),
reg189(189),
reg190(190),
reg191(191),
reg192(192),
reg193(193),
reg194(194),
reg195(195),
reg196(196),
reg197(197),
reg198(198),
reg199(199),
reg200(200),
reg201(201),
reg202(202),
reg203(203),
reg204(204),
reg205(205),
reg206(206),
reg207(207),
reg208(208),
reg209(209),
reg210(210),
reg211(211),
reg212(212),
reg213(213),
reg214(214),
reg215(215),
reg216(216),
reg217(217),
reg218(218),
reg219(219),
reg220(220),
reg221(221),
reg222(222),
reg223(223),
reg224(224),
reg225(225),
reg226(226),
reg227(227),
reg228(228),
reg229(229),
reg230(230),
reg231(231),
reg232(232),
reg233(233),
reg234(234),
reg235(235),
reg236(236),
reg237(237),
reg238(238),
reg239(239),
reg240(240),
reg241(241),
reg242(242),
reg243(243),
reg244(244),
reg245(245),
reg246(246),
reg247(247),
reg248(248),
reg249(249),
reg250(250),
reg251(251),
reg252(252),
reg253(253),
reg254(254),
reg255(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The list of regulatory bands for which the unit is
licensed to operate. A regulatory band prohibits the
wireless unit from operating outside the regulated
limits. An invalid regulatory band indicates a corrupted
license key. NB: a change of state may generate an SNMP
trap and/or SMTP email alert."
::= { licenseRegulatoryBandsTableEntry 2 }
-- Management group attribute definitions
--
targetRange OBJECT-TYPE
SYNTAX INTEGER (0..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Initial target range used in installation +/-1,
expressed in tenths of a kilometer. When Auto-Ranging
this must be set to 0"
::= { management 1 }
rangingMode OBJECT-TYPE
SYNTAX INTEGER {
auto0to40km(0),
auto0to100km(1),
auto0to200km(2),
targetRange(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of ranging to use during installation, either
Auto-Ranging or use a selectable Target Range"
::= { management 2 }
installStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
wrongPeer(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { management 3 }
installArmState OBJECT-TYPE
SYNTAX INTEGER {
disarmed(0),
armed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a change
of state may generate an SNMP trap and/or SMTP email
alert"
::= { management 4 }
tFTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 6 }
tFTPSoftwareUpgradeFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Filename of the Software Upgrade to be loaded from the
TFTP Server"
::= { management 7 }
tFTPStartSoftwareUpgrade OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write '1' to this attribute to start the TFTP software
upgrade process. The attribute will be reset to 0 when
the upgrade process has finished. Continuing with the
software upgrade will cause spectrum management (DSO)
channel metrics collection to stop. The wireless unit
will no longer search for the optimal operational radio
channel. The performance of this wireless link may
deterioate over time. If operating in a regulatory band
where RADAR detection is mandatory you must complete the
software upgrade and reboot the unit. Channel metrics
collection will only be restarted after the wireless unit
has been rebooted"
::= { management 8 }
tFTPSoftwareUpgradeStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
uploadinprogress(1),
uploadsuccessfulprogrammingFLASH(2),
upgradesuccessfulreboottorunthenewsoftwareimage(3),
upgradefailed(4),
upgradewarning(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the TFTP Software upgrade process"
::= { management 9 }
tFTPSoftwareUpgradeStatusText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Descriptive text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 10 }
tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any additional text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 11 }
hTTPAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTP access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTP port. Remote
management via HTTPS is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 12 }
telnetAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not Telnet access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the TELNET port. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = Disabled)"
::= { management 13 }
hTTPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTP access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 80)"
::= { management 14 }
hTTPSPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTPS access. A value
of zero will use the default port number. Availability of
HTTPS is controlled via the License Key. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 443)"
::= { management 15 }
telnetPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for TELNET access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 23)"
::= { management 16 }
hTTPSAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTPS access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTPS port. Remote
management via HTTP is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 17 }
tFTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
tFTPServerInternetAddress."
::= { management 18 }
tFTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"INET address of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 19 }
lowestDataModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest modulation mode at which Ethernet Data
traffic will be bridged over the wireless link"
::= { management 20 }
lowestSecondDataModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest modulation mode at which Second Data Service
Ethernet traffic will be bridged over the wireless link"
::= { management 21 }
-- PhyControl group attribute definitions
--
linkSymmetry OBJECT-TYPE
SYNTAX INTEGER {
symmetryAdaptive(0),
symmetry2to1(1),
symmetry1to1(2),
symmetry1to2(3),
symmetry3to1(4),
symmetry1to3(5),
symmetry5to1(6),
symmetry1to5(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides configuration options for sharing the available
wireless capacity between the transmit and receive
directions. Fixed link symmetry is defined by a ratio of
the burst duration for the transmit direction to the
burst duration for the receive direction. Permitted
settings are 5:1, 3:1, 2:1, 1:1, 1:2, 1:3, 1:5. The 1:1
option provides fixed symmetric operation. The adaptive
option selects transmit and receive burst durations
automatically in response to the offered Ethernet traffic
in each link direction. This attribute is valid only for
a unit configured as a TDD Master"
::= { phyControl 1 }
userConfiguredMaxModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modBpsk63percent(0),
modQpsk63percent(1),
modQpsk87percent(2),
mod16qam63percent(3),
mod16qam87percent(4),
mod64qam75percent(5),
mod64qam92percent(6),
mod256qam81percent(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum receive modulation mode controls the MAX
mode used for adaptive modulation. NOTE: This attribute
is automatically disabled when the installation agent is
armed. To disarm the installation agent use the
installation wizard"
::= { phyControl 2 }
linkModeOptimization OBJECT-TYPE
SYNTAX INTEGER {
iPTraffic(0),
tDMTraffic(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optimizes the wireless link behavior for the type of
traffic to be carried. In 'IP Traffic' mode, the wireless
link will minimize transmission errors by automatically
adapting the modulation mode. In 'TDM Traffic' mode, the
wireless link will minimize transmission latency and
preserve throughput by maintaining a higher modulation
mode in the presence of a limited number of errors. The
'TDM Traffic' mode is recommended for E1/T1 applications
and connectionless protocols."
::= { phyControl 3 }
txColorCode OBJECT-TYPE
SYNTAX INTEGER {
a(0),
b(1),
c(2),
d(3),
e(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit Color Code. This attribute need only be
considered when the unit is installed in a network of PTP
units and where some of the units are operating on the
same frequency. In this case, the value would normally be
derived by a network planner. In all other cases, it is
recommended that this attribute is left at the default
value. NOTE: For the link to operate, the value of this
parameter must in all cases match the value of the Rx
Color Code parameter at the far end of the link."
::= { phyControl 4 }
rxColorCode OBJECT-TYPE
SYNTAX INTEGER {
a(0),
b(1),
c(2),
d(3),
e(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive Color Code. This attribute need only be
considered when the unit is installed in a network of PTP
units and where some of the units are operating on the
same frequency. In this case, the value would normally be
derived by a network planner. In all other cases, it is
recommended that this attribute is left at the default
value. NOTE: For the link to operate, the value of this
parameter must in all cases match the value of the Tx
Color Code parameter at the far end of the link."
::= { phyControl 5 }
remoteMaximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-15..30)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the remote wireless unit is
permitted to use when establishing and maintaining the
wireless link"
::= { phyControl 6 }
-- PhyStatus group attribute definitions
--
linkLoss OBJECT-TYPE
SYNTAX INTEGER (-500..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless link loss expressed in tenths of a dB"
::= { phyStatus 1 }
receivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive power expressed in tenths of a dBm"
::= { phyStatus 2 }
vectorError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vector error measurement compares the received
signal's IQ modulation characteristics to an ideal signal
to determine the composite error vector magnitude. The
value represented by this attribute is the average vector
error over the previous second expressed in tenths of a
dB"
::= { phyStatus 3 }
transmitPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit power expressed in tenths of a dBm"
::= { phyStatus 4 }
receiveChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive channel"
::= { phyStatus 5 }
transmitChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit channel"
::= { phyStatus 6 }
receiveFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..6050)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed in integer MHz"
::= { phyStatus 7 }
transmitFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..6050)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed in integer MHz"
::= { phyStatus 8 }
signalStrengthRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal strength ratio (Vertical / Horizontal) : the
number of dB larger the Vertical antenna input is than
the Horizontal antenna input expressed in tenths of a dB"
::= { phyStatus 9 }
receiveFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..6050000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed as KHz"
::= { phyStatus 10 }
transmitFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..6050000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed as KHz"
::= { phyStatus 11 }
rawReceivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raw receive power expressed in tenths of a dBm"
::= { phyStatus 12 }
range OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distance between the two peer wireless units expressed
in tenths of a kilometer"
::= { phyStatus 13 }
receiveModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive modulation mode"
::= { phyStatus 14 }
transmitModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit modulation mode"
::= { phyStatus 15 }
searchState OBJECT-TYPE
SYNTAX INTEGER {
registering(0),
searching(1),
acquiring(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Search status of the wireless modem. 'Registering' means
that the modem has locked to an OFDM signal, and the
wireless link is up. 'Searching' means that no wireless
signal has been detected. 'Acquiring' means that a
wireless signal has been detected, but the modem has not
locked to an OFDM signal."
::= { phyStatus 16 }
-- Alarms group attribute definitions
--
unitOutOfCalibration OBJECT-TYPE
SYNTAX INTEGER {
calibrated(0),
partialCalibration(1),
invalidCalibration(2),
bandwidthvariantunsupportedPAsShutdown(3),
outOfCalibrationPAsShutdown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { alarms 1 }
incompatibleRegulatoryBands OBJECT-TYPE
SYNTAX INTEGER {
regOK(0),
regIncompatibleLicenseKeys(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The master and slave units have incompatible regulatory
bands. NB: Both units must have compatible license keys"
::= { alarms 4 }
noWirelessChannelAvailable OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
noWirelessChannelAvailable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { alarms 5 }
wirelessLinkDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { alarms 6 }
mainPSUPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { alarms 7 }
sFPError OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
installedSFPNotLicensed(1),
fiberLinkNotEstablishedButLOSNotDetected(2),
fiberLinkNotEstablishedAndLOSDetected(3),
installedSFPNotSupported(4),
sFPInitializationFailed(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the SFP link is not OK, there are five possible
causes: Either a SFP has been installed but the license
key does not include SFP fiber support, a fiber link
could not be established even though no LOS was detected
(i.e. an optical carrier was detected, which could be due
to a broken TX fiber, or because the link is disabled at
the fiber link partner), a fiber link could not be
established and LOS is detected (i.e. no optical carrier
is detected), the installed SFP is not supported or the
installed SFP failed to initialize correctly. NB: a
change of status may generate an SNMP trap and/or SMTP
email alert"
::= { alarms 8 }
mainPSUPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { alarms 9 }
incompatibleMasterAndSlave OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
incompatibleProductVariants(1),
differentSoftwareVersionsRunning(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { alarms 10 }
tDDSynchronizationStatus OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
holdover(1),
holdoverNoGPSSyncIn(2),
notSynchronized(3),
notSynchronizedNoGPSSyncIn(4),
pTPSYNCNotConnected(5),
initialising(6),
clusterTimingMaster(7),
acquiringLock(8),
inactive(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An alarm value (displayed in red) indicates that one of
the following conditions has not been met (i) An external
timing system is connected or internal timing has been
configured. (ii) The timing system is providing a useable
reference. (iii) The ODU is locked to this reference."
::= { alarms 11 }
auxPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { alarms 12 }
tDDSynchronizationAlarm OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
synchronizationLost(1),
referenceSignalLost(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { alarms 13 }
linkModeOptimizationMismatch OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
linkModeOptimizationMismatch(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { alarms 14 }
auxPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { alarms 15 }
secureModeAlarm OBJECT-TYPE
SYNTAX INTEGER {
secureModeIsActive(0),
secureModeIsNotConfigured(1),
secureModeIsConfiguredButNotActive(2),
secureModeIsNotSupported(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
The secure mode is not configured(1) state indicates that
the unit is capable of secure mode operation, and one or
more of the following security materials has not been
configured: Key Of Keys, Private Key, Public Certificate,
DRNG Entropy Status, Wireless Encryption Key. The secure
mode mode is configured but not active(2) state indicates
that the unit is capable of secure mode operation, and
the security material has been configured, but the
configuration of interfaces is not consistent with secure
mode operation. The secure mode is not supported(3) state
indicates that the unit is not capable of secure mode
operation. The secure mode capability requires
appropriate hardware compatibility, license key and
software image."
::= { alarms 16 }
dataBridgingStatusAlarm OBJECT-TYPE
SYNTAX INTEGER {
bridgingEnabled(0),
bridgingDisabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet Data traffic bridging is disabled because the
wireless link is not operating at the configured Lowest
Data Modulation Mode"
::= { alarms 17 }
sFPPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { alarms 18 }
sFPPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { alarms 19 }
maxLinkRangeExceeded OBJECT-TYPE
SYNTAX INTEGER {
maxLinkRangeOK(0),
maxLinkRangeExceeded(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured link range is greater than the maximum
allowed by the license key. The link will operate at a
reduced capacity while this condition applies. This alarm
is only raised if the license specifies a maximum link
range and the trial license is not active."
::= { alarms 20 }
nIDULanPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { alarms 21 }
nIDULanPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch."
::= { alarms 22 }
portAllocationMismatch OBJECT-TYPE
SYNTAX INTEGER {
portAllocationOK(0),
mismatchinSecondDataService(1),
mismatchinOutofBandRemoteManagementService(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local and remote ODUs have different services
configured."
::= { alarms 23 }
secondDataBridgingStatusAlarm OBJECT-TYPE
SYNTAX INTEGER {
bridgingEnabled(0),
bridgingDisabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bridging of Ethernet traffic from Second Data Service
has been disabled because the wireless link is not
operating at the configured Lowest Second Data Modulation
Mode"
::= { alarms 24 }
transparentClockSourcePortAlarm OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
invalidTransparentClockSourcePort(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transparent Clock will not function properly because
SFP, the selected clock source port is not FIBER"
::= { alarms 25 }
-- Smtp group attribute definitions
--
sMTPEmailAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Simple Mail Transfer Protocol is used to send equipment
alerts via email to a specified email address"
::= { smtp 1 }
sMTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port number of the SMTP server"
::= { smtp 3 }
sMTPSourceEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'from' email address used when constructing the
automatically generated e-mail message"
::= { smtp 4 }
sMTPDestinationEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'to' email address used when constructing the
automatically generated e-mail message"
::= { smtp 5 }
sMTPEnabledMessages OBJECT-TYPE
SYNTAX BITS {
nIDULanPortUpDown(0),
sFPPortUpDown(1),
auxPortUpDown(2),
mainPSUPortUpDown(3),
enabledDiagnosticAlarms(4),
dFSImpulseInterference(5),
channelChange(6),
wirelessLinkUpDown(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SMTP messages the unit will send"
::= { smtp 6 }
sMTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sMTPServerInternetAddress."
::= { smtp 7 }
sMTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet address of the SMTP server"
::= { smtp 8 }
-- SnmpControl group attribute definitions
--
sNMPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number used to access the SNMP MIB (i.e.
Gets and Sets) (default = 161). NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 1 }
sNMPCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP community string. NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 2 }
sNMPTrapTableNumber OBJECT-TYPE
SYNTAX INTEGER (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the sNMPTrapTable."
::= { snmpControl 3 }
sNMPTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(0),
v2c(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP protocol version to use for SNMP Traps. NB: A
system reboot is required to activate changes to this
attribute"
::= { snmpControl 5 }
sNMPEnabledTraps OBJECT-TYPE
SYNTAX BITS {
auxPortUpDown(0),
mainPSUPortUpDown(1),
authenticationFailure(2),
enabledDiagnosticAlarms(3),
dFSImpulseInterference(4),
channelChange(5),
wirelessLinkUpDown(6),
coldStart(7),
nIDULanPortUpDown(14),
sFPPortUpDown(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SNMP Traps the unit will send"
::= { snmpControl 6 }
enabledDiagnosticAlarms OBJECT-TYPE
SYNTAX BITS {
portState(0),
incompatibleMasterAndSlave(1),
incompatibleRegulatoryBands(2),
maximumLinkRangeExceeded(3),
unitOutOfCalibration(4),
installArmState(5),
installStatus(6),
regulatoryBand(7),
syslogLocalWrapped(8),
syslogLocalNearlyFull(9),
syslogDisabledWarning(10),
linkModeOptimizationMismatch(11),
tDDSynchronizationAlarm(12),
wirelessLinkDisabledWarning(13),
sNTPSynchronizationFailed(14),
noWirelessChannelAvailable(15),
tDMAlarms(18),
capacityVariantMismatch(19),
remainingFullCapacityTrialTime(20),
dataBridgingStatus(21),
unknown18(22),
syslogClientDisabledWarning(23)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which individual diagnostic alarms are enabled.
The unit may be configured to generate SNMP traps and/or
SMTP email alerts for these enabled alarms by selecting
'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps'
and/or 'SMTP Enabled Messages' attributes"
::= { snmpControl 7 }
sNMPSendAllTrapsAtStartup OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether cleared traps are reported at start-up
as well as raised traps. Only enabled traps will be
reported. NB: Traps corresponding to transient events
(i.e. not associated with an alarm or status value) are
only sent when required and not at start-up."
::= { snmpControl 8 }
-- SNMPTrapTable group attribute definitions
--
sNMPTrapTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP trap value, used to index the SNMPTrapTable."
::= { sNMPTrapTableEntry 1 }
sNMPTrapPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination port for SNMP Traps (default=162). NB: A
system reboot is required to activate changes to this
attribute."
::= { sNMPTrapTableEntry 3 }
sNMPTrapInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sNMPTrapInternetAddress."
::= { sNMPTrapTableEntry 4 }
sNMPTrapInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Internet address to which all SNMP Traps are sent."
::= { sNMPTrapTableEntry 5 }
sNMPTrapReceiverEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of 0 disables the sending of SNMP trap to
corresponding receiver. A value of 1 enables the sending
of SNMP trap to corresponding receiver."
::= { sNMPTrapTableEntry 6 }
-- Sntp group attribute definitions
--
sNTPState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNTP control state"
::= { sntp 1 }
sNTPPollInterval OBJECT-TYPE
SYNTAX INTEGER (60..43200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNTP server polling interval"
::= { sntp 4 }
sNTPSync OBJECT-TYPE
SYNTAX INTEGER {
noSync(0),
inSync(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP"
::= { sntp 5 }
sNTPLastSync OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last SNTP sync time"
::= { sntp 6 }
systemClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System clock presented as local time"
::= { sntp 7 }
timeZone OBJECT-TYPE
SYNTAX INTEGER {
gmtMinus1200(0),
gmtMinus1130(1),
gmtMinus1100(2),
gmtMinus1030(3),
gmtMinus1000(4),
gmtMinus0930(5),
gmtMinus0900(6),
gmtMinus0830(7),
gmtMinus0800(8),
gmtMinus0730(9),
gmtMinus0700(10),
gmtMinus0630(11),
gmtMinus0600(12),
gmtMinus0530(13),
gmtMinus0500(14),
gmtMinus0430(15),
gmtMinus0400(16),
gmtMinus0330(17),
gmtMinus0300(18),
gmtMinus0230(19),
gmtMinus0200(20),
gmtMinus0130(21),
gmtMinus0100(22),
gmtMinus0030(23),
gmtZero(24),
gmtPlus0030(25),
gmtPlus0100(26),
gmtPlus0130(27),
gmtPlus0200(28),
gmtPlus0230(29),
gmtPlus0300(30),
gmtPlus0330(31),
gmtPlus0400(32),
gmtPlus0430(33),
gmtPlus0500(34),
gmtPlus0530(35),
gmtPlus0600(36),
gmtPlus0630(37),
gmtPlus0700(38),
gmtPlus0730(39),
gmtPlus0800(40),
gmtPlus0830(41),
gmtPlus0900(42),
gmtPlus0930(43),
gmtPlus1000(44),
gmtPlus1030(45),
gmtPlus1100(46),
gmtPlus1130(47),
gmtPlus1200(48),
gmtPlus1230(49),
gmtPlus1300(50)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time zone offsets from Greenwich Mean Time (GMT)"
::= { sntp 8 }
daylightSaving OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Daylight Saving Time"
::= { sntp 9 }
sNTPPrimaryServer OBJECT-TYPE
SYNTAX INTEGER {
server1(0),
server2(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the primary SNTP server, determining the order
in which the servers are tried."
::= { sntp 10 }
sNTPPrimaryServerDeadTime OBJECT-TYPE
SYNTAX INTEGER (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time (in seconds) to wait before retrying communications
with an unresponsive primary SNTP server. Setting the
value to 0 disables the timer."
::= { sntp 11 }
sNTPServerRetries OBJECT-TYPE
SYNTAX INTEGER (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times the PTP will retry after an SNTP server
fails to respond."
::= { sntp 12 }
sNTPServerTimeout OBJECT-TYPE
SYNTAX INTEGER (1..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time (in seconds) the PTP will wait for a response from
an SNTP server."
::= { sntp 13 }
sNTPServerTableNumber OBJECT-TYPE
SYNTAX INTEGER (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the SNTPServerTable."
::= { sntp 14 }
-- SNTPServerTable group attribute definitions
--
sNTPServerTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index range for the SNTPServerTable."
::= { sNTPServerTableEntry 1 }
sNTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number of the SNTP server. Defaults to port
123."
::= { sNTPServerTableEntry 3 }
sNTPServerStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status message reflecting the result of communications
with the SNTP server when last polled"
::= { sNTPServerTableEntry 4 }
sNTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sNTPServerInternetAddress."
::= { sNTPServerTableEntry 5 }
sNTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Internet address of a valid SNTP server"
::= { sNTPServerTableEntry 6 }
-- Reset group attribute definitions
--
systemReset OBJECT-TYPE
SYNTAX INTEGER {
running(0),
consoleReboot(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to '1' will cause a system
reboot. NB: a system reboot will apply any pending new
settings held in memory"
::= { reset 1 }
-- Versions group attribute definitions
--
softwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current software version"
::= { versions 1 }
hardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware platform version"
::= { versions 2 }
secondarySoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Secondary software version, used when the primary
software image is invalid or erased"
::= { versions 3 }
bootVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Boot code software version"
::= { versions 4 }
-- PubStats group attribute definitions
--
receiveDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 1 }
transmitDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 2 }
aggregateDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 3 }
wirelessLinkAvailability OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link availability calculated since the last reset of the
system counters, as a percentage multiplied by 10000 to
give four decimal places of precision"
::= { pubStats 4 }
wirelessLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(0),
registering(1),
searching(2),
acquiring(3),
radarCAC(4),
initialising(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the wireless link"
::= { pubStats 5 }
byteErrorRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reciprocal of the byte error ratio calculated since the
last reset of the system counters"
::= { pubStats 6 }
receiveModulationModeDetail OBJECT-TYPE
SYNTAX INTEGER {
runningAtMaximumReceiveMode(0),
runningAtUserConfiguredMaxModulationMode(1),
restrictedBecauseInstallationIsArmed(2),
restrictedBecauseOfByteErrorsOnTheWirelessLink(3),
restrictedBecauseTheLinkParametersAreUpdating(4),
restrictedBecauseChannelChangeIsInProgress(5),
restrictedDueToTheLowEthernetLinkSpeed(6),
runningAtMaximumReceiveModeForChannelBandwidth(7),
limitedByTheWirelessConditions(8),
restrictedBecauseFullCapabilityTrialLicenseExpired(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reason for the current receive modulation mode"
::= { pubStats 7 }
dataBridgingAvailability OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link availability bridging Ethernet Data traffic
calculated since the last reset of the system counters,
as a percentage multiplied by 10000 to give four decimal
places of precision"
::= { pubStats 8 }
-- Encryption group attribute definitions
--
encryptionAlgorithm OBJECT-TYPE
SYNTAX INTEGER {
none(0),
aESRijndael(1),
aES192bitRijndael(2),
aES256bitRijndael(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Encryption Algorithm used by the wireless link. NB:
A system reboot is required to activate changes to this
attribute. NB: The same Encryption Algorithm must be
configured at BOTH ends of the link for it to function
correctly"
::= { encryption 1 }
-- TDDControl group attribute definitions
--
tDDSynchronizationMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TDD Synchronization Mode selection"
::= { tDDControl 1 }
-- AAAControl group attribute definitions
--
userTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the userTable"
::= { aAAControl 1 }
-- UserTable group attribute definitions
--
userTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the userTable."
::= { userTableEntry 1 }
userName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..67))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User name which must be entered, along with the
appropriate password, in order to gain access to the
system."
::= { userTableEntry 2 }
userRole OBJECT-TYPE
SYNTAX INTEGER {
readOnly(0),
systemAdministrator(1),
securityOfficer(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Role of the selected user. A Security Officer has access
to and can modify all settings. A System Administrator
has access to and can modify all non-security settings. A
Read Only user can view settings, but cannot make any
changes."
::= { userTableEntry 3 }
userEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable / Disable the selected user"
::= { userTableEntry 4 }
userPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..67))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User password, which must be entered in order to gain
access to the system."
::= { userTableEntry 5 }
-- SyslogControl group attribute definitions
--
syslogClient OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { syslogControl 1 }
syslogState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { syslogControl 2 }
-- RouterProtocols group attribute definitions
--
microwaveAdaptiveBandwidth OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable support of Microwave Adaptive Bandwidth Protocol.
MAB is disabled if link symmetry is configured as
Adaptive"
::= { routerProtocols 1 }
mABNominalModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Nominal modulation mode is the desired modulation
mode. MAB VSM packets are generated when the current
modulation mode falls below the nominal modulation."
::= { routerProtocols 2 }
mABTransmissionInterval OBJECT-TYPE
SYNTAX INTEGER {
transmissionInterval1s(0),
transmissionInterval10s(1),
transmissionInterval60s(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum interval (in seconds) between successive MAB
vendor specific messages (VSM). These VSM are sent when
the current transmit capacity falls below the configured
MAB Nominal Modulation Mode."
::= { routerProtocols 3 }
mABHoldoffPeriod OBJECT-TYPE
SYNTAX INTEGER (10..60)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The period (in seconds) over which transmit capacity is
averaged over to determine when the wireless link has
degraded"
::= { routerProtocols 4 }
mABMaintenanceLevel OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maintenance Levels (0-7) determines the destination MAC
address of MAB vendor specific messages."
::= { routerProtocols 5 }
useVLANForMABProtocol OBJECT-TYPE
SYNTAX INTEGER {
noVLANTagging(0),
iEEE8021QTaggedCTagType8100(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls whether MAB vendor specific messages (VSM)
packets use VLAN tags or not."
::= { routerProtocols 6 }
mABProtocolVID OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This VLAN VID (0-4094) will be included in MAB vendor
specific messages (VSM) packets."
::= { routerProtocols 7 }
mABProtocolVLANPriority OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This VLAN Priority (0-7) will be included in MAB vendor
specific messages (VSM) packets."
::= { routerProtocols 8 }
mABState OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
degraded(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of MAB Protocol. A state of 'Normal' on a
green background indicates that a PTP link is operating
at nominal capacity"
::= { routerProtocols 9 }
mABNominalTransmitCapacity OBJECT-TYPE
SYNTAX INTEGER (0..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal Tx capacity used in MAB Vendor Specific
Messages for the selected nominal modulation mode "
::= { routerProtocols 10 }
mABCurrentTransmitCapacity OBJECT-TYPE
SYNTAX INTEGER (0..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx capacity of the wireless link used in the
last MAB Vendor Specific Message transmitted."
::= { routerProtocols 11 }
-- CableDiagnostics group attribute definitions
--
cableDiagnosticsPorts OBJECT-TYPE
SYNTAX BITS {
auxPort(6),
mainPSUPort(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select ports on which Cable Diagnostics must be
executed"
::= { cableDiagnostics 1 }
cableDiagnosticsControl OBJECT-TYPE
SYNTAX INTEGER {
startTest(0),
testInProgress(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set this attribute to 'Test in Progress' to start a
Cable Diagnostics test"
::= { cableDiagnostics 2 }
cableDiagnosticsWarning OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
testInProgress(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Normal Ethernet operation is disrupted when a Cable
Diagnostics test is in progress"
::= { cableDiagnostics 3 }
cableDiagnosticsResultTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of rows in the Cable Diagnostics Result Table."
::= { cableDiagnostics 4 }
-- CableDiagnosticsResultTable group attribute definitions
--
cableDiagnosticsResultTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cable Diagnostics Port value used to index into the
result table."
::= { cableDiagnosticsResultTableEntry 1 }
cableDiagnosticsResultsDateTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Date and Time when a Cable Diagnostics test was last
executed"
::= { cableDiagnosticsResultTableEntry 2 }
cableDiagPair1Results OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
unknown(1),
inProgress(2),
notTested(3),
openCircuit(4),
shortCircuit(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the most recent execution of Cable
Diagnostics on cable pair 1. According to the T658B
wiring scheme, pair 1 is pins 4 & 5 on the RJ45 socket on
the ODU. Open Circuit is reported when the impedance is
greater than 330 ohms. Short Circuit is reported when the
impedance is less than 33 ohms. Unknown is reported when
a continuous signal is received from the link partner for
125 ms, preventing start of the test."
::= { cableDiagnosticsResultTableEntry 3 }
cableDiagPair1Distance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distance in meters from the ODU to the fault
detected on the cable pair during the most recent
execution of Cable Diagnostics. Faults in cables longer
than 160 meters (525 feet) may not be detected. The error
margin is +/-2 meters (6.5 feet)."
::= { cableDiagnosticsResultTableEntry 4 }
cableDiagPair2Results OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
unknown(1),
inProgress(2),
notTested(3),
openCircuit(4),
shortCircuit(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the most recent execution of Cable
Diagnostics on cable pair 2. According to the T658B
wiring scheme, pair 2 is pins 1 & 2 on the RJ45 socket on
the ODU. Open Circuit is reported when the impedance is
greater than 330 ohms. Short Circuit is reported when the
impedance is less than 33 ohms. Unknown is reported when
a continuous signal is received from the link partner for
125 ms, preventing start of the test."
::= { cableDiagnosticsResultTableEntry 5 }
cableDiagPair2Distance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distance in meters from the ODU to the fault
detected on the cable pair during the most recent
execution of Cable Diagnostics. Faults in cables longer
than 160 meters (525 feet) may not be detected. The error
margin is +/-2 meters (6.5 feet)."
::= { cableDiagnosticsResultTableEntry 6 }
cableDiagPair3Results OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
unknown(1),
inProgress(2),
notTested(3),
openCircuit(4),
shortCircuit(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the most recent execution of Cable
Diagnostics on cable pair 3. According to the T658B
wiring scheme, pair 3 is pins 3 & 6 on the RJ45 socket on
the ODU. Open Circuit is reported when the impedance is
greater than 330 ohms. Short Circuit is reported when the
impedance is less than 33 ohms. Unknown is reported when
a continuous signal is received from the link partner for
125 ms, preventing start of the test."
::= { cableDiagnosticsResultTableEntry 7 }
cableDiagPair3Distance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distance in meters from the ODU to the fault
detected on the cable pair during the most recent
execution of Cable Diagnostics. Faults in cables longer
than 160 meters (525 feet) may not be detected. The error
margin is +/-2 meters (6.5 feet)."
::= { cableDiagnosticsResultTableEntry 8 }
cableDiagPair4Results OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
unknown(1),
inProgress(2),
notTested(3),
openCircuit(4),
shortCircuit(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of the most recent execution of Cable
Diagnostics on cable pair 4. According to the T658B
wiring scheme, pair 4 is pins 7 & 8 on the RJ45 socket on
the ODU. Open Circuit is reported when the impedance is
greater than 330 ohms. Short Circuit is reported when the
impedance is less than 33 ohms. Unknown is reported when
a continuous signal is received from the link partner for
125 ms, preventing start of the test."
::= { cableDiagnosticsResultTableEntry 9 }
cableDiagPair4Distance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distance in meters from the ODU to the fault
detected on the cable pair during the most recent
execution of Cable Diagnostics. Faults in cables longer
than 160 meters (525 feet) may not be detected. The error
margin is +/-2 meters (6.5 feet)."
::= { cableDiagnosticsResultTableEntry 10 }
-- Supplementary group attribute definitions
--
longitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The longitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 1 }
latitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The latitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 2 }
altitude OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The altitude of the unit, measured in meters. This
object is set by the SNMP manager and has no internal
function."
::= { supplementary 3 }
-- Enterprise NOTIFICATION definitions
--
channelChangeTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "The PTP radio has changed wireless channel.
This has been caused by either
i) mandatory radar avoidance,
a DFS impulsive interference event will also be
detected,
or
ii) Dynamic Spectrum Optimization, (DSO)
DSO improves link performance by selecting the
most appropriate transmit and receive channels
with the lowest level of interference."
::= { ptpTrapPrefix 1 }
dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "DFS impulsive interference detected event"
::= { ptpTrapPrefix 2 }
mainPSUPortStatusTrap NOTIFICATION-TYPE
OBJECTS { mainPSUPortStatus }
STATUS current
DESCRIPTION
"Current status of the Main PSU Ethernet link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 3 }
mainPSUPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { mainPSUPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { ptpTrapPrefix 4 }
mainPSUPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { mainPSUPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { ptpTrapPrefix 5 }
auxPortStatusTrap NOTIFICATION-TYPE
OBJECTS { auxPortStatus }
STATUS current
DESCRIPTION
"Current status of the Aux Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 6 }
auxPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { auxPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { ptpTrapPrefix 7 }
regulatoryBandTrap NOTIFICATION-TYPE
OBJECTS { regulatoryBand }
STATUS current
DESCRIPTION
"The Regulatory Band prohibits the wireless unit from
operating outside the regulated limits. An invalid
Regulatory Band may be caused by a missing or incorrect
License Key, a corrupt MAC Address or an attempt to
configure a Regulatory Band not allowed by the License
Key. NB: a change of state may generate an SNMP trap
and/or SMTP email alert."
::= { ptpTrapPrefix 8 }
installStatusTrap NOTIFICATION-TYPE
OBJECTS { installStatus }
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { ptpTrapPrefix 9 }
installArmStateTrap NOTIFICATION-TYPE
OBJECTS { installArmState }
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a change
of state may generate an SNMP trap and/or SMTP email
alert"
::= { ptpTrapPrefix 10 }
unitOutOfCalibrationTrap NOTIFICATION-TYPE
OBJECTS { unitOutOfCalibration }
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { ptpTrapPrefix 11 }
auxPortPowerOverEthernetOutputStatusTrap NOTIFICATION-TYPE
OBJECTS { auxPortPowerOverEthernetOutputStatus }
STATUS current
DESCRIPTION
"Current status of the Power Over Ethernet (PoE) output
of the Aux port"
::= { ptpTrapPrefix 12 }
incompatibleRegulatoryBandsTrap NOTIFICATION-TYPE
OBJECTS { incompatibleRegulatoryBands }
STATUS current
DESCRIPTION
"The master and slave units have incompatible regulatory
bands. NB: Both units must have compatible license keys"
::= { ptpTrapPrefix 14 }
noWirelessChannelAvailableTrap NOTIFICATION-TYPE
OBJECTS { noWirelessChannelAvailable }
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { ptpTrapPrefix 15 }
wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { wirelessLinkDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { ptpTrapPrefix 16 }
auxPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { auxPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { ptpTrapPrefix 17 }
sFPErrorTrap NOTIFICATION-TYPE
OBJECTS { sFPError }
STATUS current
DESCRIPTION
"If the SFP link is not OK, there are five possible
causes: Either a SFP has been installed but the license
key does not include SFP fiber support, a fiber link
could not be established even though no LOS was detected
(i.e. an optical carrier was detected, which could be due
to a broken TX fiber, or because the link is disabled at
the fiber link partner), a fiber link could not be
established and LOS is detected (i.e. no optical carrier
is detected), the installed SFP is not supported or the
installed SFP failed to initialize correctly. NB: a
change of status may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 18 }
sFPPortStatusTrap NOTIFICATION-TYPE
OBJECTS { sFPPortStatus }
STATUS current
DESCRIPTION
"Current status of the SFP Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 19 }
incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE
OBJECTS { incompatibleMasterAndSlave }
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 20 }
sNTPSyncTrap NOTIFICATION-TYPE
OBJECTS { sNTPSync }
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP"
::= { ptpTrapPrefix 21 }
tDDSynchronizationAlarmTrap NOTIFICATION-TYPE
OBJECTS { tDDSynchronizationAlarm }
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { ptpTrapPrefix 22 }
sFPPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { sFPPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { ptpTrapPrefix 23 }
sFPPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { sFPPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { ptpTrapPrefix 24 }
linkModeOptimizationMismatchTrap NOTIFICATION-TYPE
OBJECTS { linkModeOptimizationMismatch }
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { ptpTrapPrefix 25 }
tDMInterfaceStatusTrap NOTIFICATION-TYPE
OBJECTS { tDMInterfaceStatus }
STATUS current
DESCRIPTION
"@Current status of the connection to the TDM Box. A
state of 'Up' on a green background indicates that the
TDM Box is connected OK. When connecting a TDM Box only
the Main Ethernet port should be used"
::= { ptpTrapPrefix 26 }
tDMChannelStatusTrap NOTIFICATION-TYPE
OBJECTS { tDMChannelStatus }
STATUS current
DESCRIPTION
"Current status of the TDM channels. A value of 0
indicates that a TDM channel is established"
::= { ptpTrapPrefix 27 }
tDMChannelLoopbackTrap NOTIFICATION-TYPE
OBJECTS { tDMChannelLoopback }
STATUS current
DESCRIPTION
"The loopback status of TDM channels. This is intended
for installation testing and should be set to 'None' for
normal operation. The wire connections to a unit can be
tested by applying a 'Copper' loopback to the local unit.
The wireless connection to the remote unit can be tested
by applying a 'Wireless' loopback to the remote unit with
no loopback on the local unit. NB: a change of state may
generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 28 }
nIDULanPortStatusTrap NOTIFICATION-TYPE
OBJECTS { nIDULanPortStatus }
STATUS current
DESCRIPTION
"Current status of the NIDU LAN Ethernet link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 29 }
syslogStateTrap NOTIFICATION-TYPE
OBJECTS { syslogState }
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { ptpTrapPrefix 30 }
syslogLocalNearlyFullTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log is nearly full (90%)"
::= { ptpTrapPrefix 31 }
syslogLocalWrappedTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log has wrapped"
::= { ptpTrapPrefix 32 }
syslogClientTrap NOTIFICATION-TYPE
OBJECTS { syslogClient }
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { ptpTrapPrefix 33 }
secureModeAlarmTrap NOTIFICATION-TYPE
OBJECTS { secureModeAlarm }
STATUS current
DESCRIPTION
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
The secure mode is not configured(1) state indicates that
the unit is capable of secure mode operation, and one or
more of the following security materials has not been
configured: Key Of Keys, Private Key, Public Certificate,
DRNG Entropy Status, Wireless Encryption Key. The secure
mode mode is configured but not active(2) state indicates
that the unit is capable of secure mode operation, and
the security material has been configured, but the
configuration of interfaces is not consistent with secure
mode operation. The secure mode is not supported(3) state
indicates that the unit is not capable of secure mode
operation. The secure mode capability requires
appropriate hardware compatibility, license key and
software image."
::= { ptpTrapPrefix 34 }
dataBridgingStatusAlarmTrap NOTIFICATION-TYPE
OBJECTS { dataBridgingStatusAlarm }
STATUS current
DESCRIPTION
"Ethernet Data traffic bridging is disabled because the
wireless link is not operating at the configured Lowest
Data Modulation Mode"
::= { ptpTrapPrefix 35 }
licenseRemainingTrialPeriodAlarmTrap NOTIFICATION-TYPE
OBJECTS { licenseRemainingTrialPeriodAlarm }
STATUS current
DESCRIPTION
"If the full capability trial license period is about to
expire then purchase a license upgrade from your
reseller."
::= { ptpTrapPrefix 36 }
capacityVariantMismatchTrap NOTIFICATION-TYPE
OBJECTS { capacityVariantMismatch }
STATUS current
DESCRIPTION
"The remote node of this link has a lower link capacity.
Operating with a reduced effective link capacity."
::= { ptpTrapPrefix 37 }
maxLinkRangeExceededTrap NOTIFICATION-TYPE
OBJECTS { maxLinkRangeExceeded }
STATUS current
DESCRIPTION
"The measured link range is greater than the maximum
allowed by the license key. The link will operate at a
reduced capacity while this condition applies. This alarm
is only raised if the license specifies a maximum link
range and the trial license is not active."
::= { ptpTrapPrefix 38 }
tDMConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { tDMConfigurationMismatch }
STATUS current
DESCRIPTION
"Current status of the configuration of the TDM Box. A
state of 'Ok' on a green background indicates that the
TDM Box configuration is matched OK with the remote end."
::= { ptpTrapPrefix 39 }
nIDULanPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { nIDULanPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the interface has disabled
Ethernet traffic"
::= { ptpTrapPrefix 40 }
nIDULanPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { nIDULanPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch."
::= { ptpTrapPrefix 41 }
secondDataBridgingStatusAlarmTrap NOTIFICATION-TYPE
OBJECTS { secondDataBridgingStatusAlarm }
STATUS current
DESCRIPTION
"Bridging of Ethernet traffic from Second Data Service
has been disabled because the wireless link is not
operating at the configured Lowest Second Data Modulation
Mode"
::= { ptpTrapPrefix 42 }
transparentClockSourcePortAlarmTrap NOTIFICATION-TYPE
OBJECTS { transparentClockSourcePortAlarm }
STATUS current
DESCRIPTION
"Transparent Clock will not function properly because
SFP, the selected clock source port is not FIBER"
::= { ptpTrapPrefix 43 }
portAllocationMismatchTrap NOTIFICATION-TYPE
OBJECTS { portAllocationMismatch }
STATUS current
DESCRIPTION
"The local and remote ODUs have different services
configured."
::= { ptpTrapPrefix 44 }
END