-- Copyright (c) 2004-2019 New H3C Tech. Co., Ltd. All rights reserved.
|
|||
|
--
|
|||
|
-- Description: Power over ethernet extend MIB
|
|||
|
-- Reference: POWER-ETHERNET-MIB
|
|||
|
-- Version: V1.7
|
|||
|
-- History:
|
|||
|
-- V1.0 2004-07-24 Created by Gaolong
|
|||
|
-- V1.1 2004-09-08 Update file by Gaolong for some syntax errors.
|
|||
|
-- V1.2 2004-11-19 Update file by liuhongxu for poe need.
|
|||
|
-- add hh3cMainPsePriorityMode<64><65>hh3cPsePowerMaxValue<75><65>
|
|||
|
-- hh3cpsePDChangNotification adjust the objects' sequence of
|
|||
|
-- hh3cPsePortTable and hh3cMainPseTable add the description
|
|||
|
-- of MANDATORY-GROUPS in hh3cPseCompliance.
|
|||
|
-- V1.3 2004-12-16 Update file by liuhongxu for poe profile
|
|||
|
-- add hh3cPsePortProfile, hh3cPseProfilesTable
|
|||
|
-- change the name of hh3cPseProfileIndex add
|
|||
|
-- hh3cPseProfileApplyNum. adjust the format of this mib.
|
|||
|
-- V1.4 2005-03-29 Update file by Wangzhaoyan for poe pow need.
|
|||
|
-- add hh3cPOEPowerObjects, hh3cPOEThresholdLimitObjs,
|
|||
|
-- hh3cPOESupModuleInfoObjs, hh3cPOEDCOutStateObjects,
|
|||
|
-- hh3cPOEDCDCOutInfoObjects, hh3cPOEACSwitchStateModuleObjs,
|
|||
|
-- hh3cPOEInCurStateObjects, hh3cPOEAlarmStateObjects and the
|
|||
|
-- sub-nodes. add 17 traps change the node name from
|
|||
|
-- hh3cpsePDChangNotification to hh3cpsePDChangeNotification
|
|||
|
-- change some detail as the suggestion from Wangyingxia and
|
|||
|
-- Yangyang. adjust the format of this mib.
|
|||
|
-- V1.5 2005-11-21 Update file by Liweizhen for controling the power-management
|
|||
|
-- policy of PSE or PD. Add hh3cPsePolicyMode, hh3cPDPolicyMode,
|
|||
|
-- hh3cMainPsePowerPriority.
|
|||
|
-- Delete some description of hh3cPsePortProfileIndex node.
|
|||
|
-- Change the description of hh3cPseProfilePowerMode node.
|
|||
|
-- Change SYNTAX OCTET STRING range for the following nodes:
|
|||
|
-- hh3cPOEPowerType, hh3cPOESupervisionModuleName,
|
|||
|
-- hh3cPOESMFactorName, hh3cPOEModuleHardVerInfo.
|
|||
|
-- Adjust the format of this mib.
|
|||
|
-- V1.6 2015-07-21 Update file by Fangliwen for profile power limit.
|
|||
|
-- Change the syntax of hh3cPseProfilePowerLimit node.
|
|||
|
-- V1.7 2019-5-23 Update file for PoE-AI. Add the following nodes:
|
|||
|
-- hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
|
|||
|
-- hh3cPsePortIndex and hh3cPsePortDisableInfo.
|
|||
|
-- =================================================================
|
|||
|
HH3C-POWER-ETH-EXT-MIB DEFINITIONS ::= BEGIN
|
|||
|
|
|||
|
IMPORTS
|
|||
|
hh3cCommon
|
|||
|
FROM HH3C-OID-MIB
|
|||
|
pethPsePortGroupIndex, pethPsePortIndex,
|
|||
|
pethMainPseGroupIndex, pethPsePortDetectionStatus
|
|||
|
FROM POWER-ETHERNET-MIB
|
|||
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|||
|
FROM SNMPv2-CONF
|
|||
|
Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|||
|
FROM SNMPv2-SMI
|
|||
|
DisplayString, RowStatus, TEXTUAL-CONVENTION
|
|||
|
FROM SNMPv2-TC;
|
|||
|
|
|||
|
|
|||
|
hh3cPowerEthernetExt MODULE-IDENTITY
|
|||
|
LAST-UPDATED "201905230000Z" -- May 23, 2019 at 00:00 GMT
|
|||
|
|
|||
|
ORGANIZATION
|
|||
|
"New H3C Tech. Co., Ltd."
|
|||
|
CONTACT-INFO
|
|||
|
"Platform Team New H3C Tech. Co., Ltd.
|
|||
|
Hai-Dian District Beijing P.R. China
|
|||
|
http://www.h3c.com
|
|||
|
Zip:100085
|
|||
|
"
|
|||
|
DESCRIPTION
|
|||
|
"Description."
|
|||
|
REVISION "201905230000Z"
|
|||
|
DESCRIPTION
|
|||
|
"Add the following nodes:
|
|||
|
hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
|
|||
|
hh3cPsePortIndex and hh3cPsePortDisableInfo."
|
|||
|
REVISION "201507250000Z"
|
|||
|
DESCRIPTION
|
|||
|
"The initial version of this MIB module."
|
|||
|
::= { hh3cCommon 14 }
|
|||
|
|
|||
|
|
|||
|
--
|
|||
|
-- Node definitions
|
|||
|
--
|
|||
|
|
|||
|
hh3cPsePortTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPsePortEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The indexing scheme is taken form that used by
|
|||
|
the IETF Power MIB. The same indexing scheme is
|
|||
|
used to give continuity in behaviour between
|
|||
|
that standard and this extensions definitioin."
|
|||
|
::= { hh3cPowerEthernetExt 1 }
|
|||
|
|
|||
|
|
|||
|
hh3cPsePortEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPsePortEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The pethPsePortGroupIndex is imported from the IETF Power MIB
|
|||
|
and uniquely identifies the group containing the port to which
|
|||
|
power ethernet PSE is connected. Group means (box in the stack,
|
|||
|
module in a rack).
|
|||
|
|
|||
|
The pethPsePortPowerIndex is imported from the IETF Power MIB
|
|||
|
and uniquely identifies the power ethernet PSE port within group
|
|||
|
pethPseGroupIndex to which the power Ethernet PSE entry is
|
|||
|
connected. This value will match the local port number on a
|
|||
|
switch."
|
|||
|
INDEX { pethPsePortGroupIndex, pethPsePortIndex }
|
|||
|
::= { hh3cPsePortTable 1 }
|
|||
|
|
|||
|
|
|||
|
Hh3cPsePortEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cPsePortFaultDescription
|
|||
|
DisplayString,
|
|||
|
hh3cPsePortPeakPower
|
|||
|
Integer32,
|
|||
|
hh3cPsePortAveragePower
|
|||
|
Integer32,
|
|||
|
hh3cPsePortCurrentPower
|
|||
|
Integer32,
|
|||
|
hh3cPsePortPowerLimit
|
|||
|
Integer32,
|
|||
|
hh3cPsePortProfileIndex
|
|||
|
Integer32
|
|||
|
}
|
|||
|
|
|||
|
hh3cPsePortFaultDescription OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object supports the fault category of the IETF Power MIB [1]
|
|||
|
pethPsePortDetectionStatus object. A textual description
|
|||
|
containing more information about the nature of this fault is
|
|||
|
provided by this object. Typically this will detail the precise
|
|||
|
PoE hardware state which is causing the pethPsePortDetectionStatus
|
|||
|
object to be in the 'fault' state.
|
|||
|
It is a DisplayString of up to 255 characters."
|
|||
|
::= { hh3cPsePortEntry 2 }
|
|||
|
|
|||
|
|
|||
|
hh3cPsePortPeakPower OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the peak power which has been consumed by
|
|||
|
the port. It is defined as the highest measured value of power
|
|||
|
in milliWatts that has been consumed by the port. Its value
|
|||
|
is only reset when link is lost, the port is PoE disabled or
|
|||
|
when it is manually reset by the user asspecified below.
|
|||
|
It is a read/write integer value with units of milliWatts.
|
|||
|
Writing a value of zero to this object resets its value
|
|||
|
to zero. Writing any other value to this object has no
|
|||
|
effect on its value and an error is returned."
|
|||
|
::= { hh3cPsePortEntry 3 }
|
|||
|
|
|||
|
|
|||
|
hh3cPsePortAveragePower OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the average power which has been consumed
|
|||
|
by the port. This object is a read/write integer value with
|
|||
|
units of milliWatts. Writing a value of zero to this object
|
|||
|
resets its value to zero. Writing any other value to this
|
|||
|
object has no effect on its value and an error is returned."
|
|||
|
::= { hh3cPsePortEntry 4 }
|
|||
|
|
|||
|
|
|||
|
hh3cPsePortCurrentPower OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the power currently being consumed by the port.
|
|||
|
It is a read only integer value with units of milliWatts."
|
|||
|
::= { hh3cPsePortEntry 5 }
|
|||
|
|
|||
|
|
|||
|
hh3cPsePortPowerLimit OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the power limit set for this port.
|
|||
|
The PSE will not supply more than this level of power to the
|
|||
|
specified port.
|
|||
|
It is a read/write integer value with units of milliWatts."
|
|||
|
::= { hh3cPsePortEntry 6 }
|
|||
|
|
|||
|
hh3cPsePortProfileIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (0..100)
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Indicates the power profile which is currently associated
|
|||
|
with this port. This object references the corresponding
|
|||
|
hh3cPseProfileIndex object in the power profiles table. A
|
|||
|
value of zero is a special case and indicates that no
|
|||
|
power profile is currently associated with this port. When
|
|||
|
hh3cPseProfileIndex is set to an index of existent profile,
|
|||
|
pethPsePortPowerPairs, pethPsePortPowerPriority,
|
|||
|
pethPsePortAdminEnable and hh3cPsePortPowerLimit will be
|
|||
|
set to the same as corresponding value. PethPsePortPowerPairs,
|
|||
|
pethPsePortPowerPriority and pethPsePortAdminEnable are objects
|
|||
|
of rfc3621-Power-Ethernet.mib."
|
|||
|
::= { hh3cPsePortEntry 7 }
|
|||
|
|
|||
|
|
|||
|
hh3cMainPseTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cMainPseEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Description."
|
|||
|
::= { hh3cPowerEthernetExt 2 }
|
|||
|
|
|||
|
|
|||
|
hh3cMainPseEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cMainPseEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The pethMainPseGroupIndex is imported from the IETF Power MIB
|
|||
|
and uniquely identifies the group containing the port to which
|
|||
|
power ethernet PSE is connected. Group means (box in the stack,
|
|||
|
module in a rack) and the value 1 MUST be used for non-modular
|
|||
|
devices."
|
|||
|
INDEX { pethMainPseGroupIndex }
|
|||
|
::= { hh3cMainPseTable 1 }
|
|||
|
|
|||
|
|
|||
|
Hh3cMainPseEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cMainPsePowerLimit
|
|||
|
Integer32,
|
|||
|
hh3cMainPseAveragePower
|
|||
|
Integer32,
|
|||
|
hh3cMainPsePeakPower
|
|||
|
Integer32,
|
|||
|
hh3cMainGuaranteedPowerRemaining
|
|||
|
Integer32,
|
|||
|
hh3cMainPsePriorityMode
|
|||
|
INTEGER,
|
|||
|
hh3cMainPseLegacy
|
|||
|
INTEGER,
|
|||
|
hh3cMainPsePowerPriority
|
|||
|
INTEGER
|
|||
|
}
|
|||
|
|
|||
|
hh3cMainPsePowerLimit OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the power limit set for the unit as a whole.
|
|||
|
The PoE unit will already have a nominal power defined by the
|
|||
|
IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object
|
|||
|
specifies a further limit to this nominal power value. This may
|
|||
|
be useful to control the thermals of the unit, or for internal
|
|||
|
testing purposes. One possible use for this object may be to lower
|
|||
|
the power consumption of the unit if one or more of the internal
|
|||
|
fans have broken. It is a read/write integer value with units of
|
|||
|
Watts (note - Watts is chosen instead of milliWatts here since
|
|||
|
the IETF Power MIB [1] measures unit based parameters, such as
|
|||
|
the pethMainPsePower object, in units of Watts)."
|
|||
|
::= { hh3cMainPseEntry 1 }
|
|||
|
|
|||
|
|
|||
|
hh3cMainPseAveragePower OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the average power which has been consumed
|
|||
|
by the port. It is a read/write integer value with units of
|
|||
|
Watts (note - Watts is chosen instead of milliWatts here since
|
|||
|
the IETF Power MIB [1] measures unit based parameters, such as
|
|||
|
the pethMainPsePower object, in units of Watts). Writing a value
|
|||
|
of zero to this object resets its value to zero. Writing any
|
|||
|
other value to this object has no effect on its value and an error
|
|||
|
is returned."
|
|||
|
::= { hh3cMainPseEntry 2 }
|
|||
|
|
|||
|
|
|||
|
hh3cMainPsePeakPower OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the peak power which has been consumed for PoE.
|
|||
|
It is defined as the highest measured value of power in milliWatts
|
|||
|
that has been consumed at any one point in time by the sum of the PoE
|
|||
|
ports. Its value is only reset when the unit is powered on or when
|
|||
|
it is manually reset by the user as specifiedbelow. It is a read/write
|
|||
|
integer value with units of Watts (note - Watts is chosen instead of
|
|||
|
milliWatts here since the IETF Power MIB [1] measures unit based
|
|||
|
parameters, such as the pethMainPsePower object, in units of Watts).
|
|||
|
Writing a value of zero to this object resets its value to zero.
|
|||
|
Writing any other value to this object has noeffect on its value
|
|||
|
and an error is returned."
|
|||
|
::= { hh3cMainPseEntry 3 }
|
|||
|
|
|||
|
|
|||
|
hh3cMainGuaranteedPowerRemaining OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the amount of power remaining in the guaranteed
|
|||
|
power pool. Each time a port is placed into guaranteed mode it
|
|||
|
reserves a set amount of power out of the total guaranteed power
|
|||
|
pool for the system. This intention of this object is to give the
|
|||
|
client of this MIB (whether that be the CLI or the Web interface or
|
|||
|
the end user) an indication of how many ports can still be placed
|
|||
|
into guaranteed mode. It is a read only integer value with units of
|
|||
|
Watts(note - Watts is chosen instead of milliWatts here since the
|
|||
|
IETF Power MIB [1] measures unit based parameters,such as the
|
|||
|
pethMainPsePower object, in units of Watts)."
|
|||
|
::= { hh3cMainPseEntry 4 }
|
|||
|
|
|||
|
|
|||
|
hh3cMainPsePriorityMode OBJECT-TYPE
|
|||
|
SYNTAX INTEGER {
|
|||
|
disconnection(0),
|
|||
|
non-disconnection(1)
|
|||
|
}
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Describes or controls the priority mode on slot which must be
|
|||
|
enabled firstly. When a new board is inserted, and the power is
|
|||
|
over-load, a value of disconnection(0) means that the power will
|
|||
|
stop supply to the low priority slot ; A value of non-disconnection(1)
|
|||
|
means that the slot still supply when a new board is inserted, and
|
|||
|
the power is over-load too."
|
|||
|
::= { hh3cMainPseEntry 5 }
|
|||
|
|
|||
|
hh3cMainPseLegacy OBJECT-TYPE
|
|||
|
SYNTAX INTEGER {
|
|||
|
enable(0),
|
|||
|
disable(1)
|
|||
|
}
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Describes or controls the legacy mode on slot which must be enabled
|
|||
|
firstly. Legacy mode: standard or nonstandard PD detection mode."
|
|||
|
::= { hh3cMainPseEntry 6 }
|
|||
|
|
|||
|
hh3cMainPsePowerPriority OBJECT-TYPE
|
|||
|
SYNTAX INTEGER {
|
|||
|
critical(1),
|
|||
|
high(2),
|
|||
|
low(3)
|
|||
|
}
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Describes or controls the priority of the PSE. The priority
|
|||
|
will be used by the PSE policy to prevent from power overloading.
|
|||
|
If the priority of PSE is set to critical, the PSE will turn into
|
|||
|
guaranteed mode. The priority could be used by a control mechanism
|
|||
|
that prevents power overloading by disconnecting PSEs with lower
|
|||
|
power priority. PSEs that connect devices critical to the
|
|||
|
application should be set to higher priority."
|
|||
|
::= { hh3cMainPseEntry 7 }
|
|||
|
|
|||
|
-- Power Profile PSE table
|
|||
|
hh3cPseProfilesTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPseProfilesEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"A table of objects representing a set of power profiles.
|
|||
|
Power profiles can be applied to PoE ports, which have the
|
|||
|
effect of automatically setting the priority, power limit
|
|||
|
and PoE enable MIB objects to the values specified in the
|
|||
|
power profile."
|
|||
|
::= { hh3cPowerEthernetExt 7 }
|
|||
|
|
|||
|
hh3cPseProfilesEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPseProfilesEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"A set of objects that display and control the Main power of a PSE."
|
|||
|
INDEX { hh3cPseProfileIndex }
|
|||
|
::= { hh3cPseProfilesTable 1 }
|
|||
|
|
|||
|
Hh3cPseProfilesEntry ::= SEQUENCE {
|
|||
|
hh3cPseProfileIndex Integer32,
|
|||
|
hh3cPseProfileName DisplayString,
|
|||
|
hh3cPseProfilePowerMode INTEGER,
|
|||
|
hh3cPseProfilePowerLimit Integer32,
|
|||
|
hh3cPseProfilePriority INTEGER,
|
|||
|
hh3cPseProfilePairs INTEGER,
|
|||
|
hh3cPseProfileApplyNum Integer32,
|
|||
|
hh3cPseProfileRowStatus RowStatus
|
|||
|
}
|
|||
|
|
|||
|
hh3cPseProfileIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..100)
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The index of the profile. This uniquely allow the profile to be
|
|||
|
identified."
|
|||
|
::= { hh3cPseProfilesEntry 1 }
|
|||
|
|
|||
|
hh3cPseProfileName OBJECT-TYPE
|
|||
|
SYNTAX DisplayString (SIZE(1..15))
|
|||
|
MAX-ACCESS read-create
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Assigns the profile a name with which the settings
|
|||
|
can be assiciated with. For example, 'NBX Phone'."
|
|||
|
::= { hh3cPseProfilesEntry 2 }
|
|||
|
|
|||
|
hh3cPseProfilePowerMode OBJECT-TYPE
|
|||
|
SYNTAX INTEGER {
|
|||
|
powerDisabled (1),
|
|||
|
powerEnabled (2)
|
|||
|
}
|
|||
|
MAX-ACCESS read-create
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The power mode associated with this power profile. There
|
|||
|
are two possible power modes as follows: powerDisabled,
|
|||
|
powerEnabled. When a power profile is applied to a PSE port,
|
|||
|
this value dictates the settings of the ports pethPsePortPowerPriority
|
|||
|
and pethPsePortAdminEnable objects."
|
|||
|
::= { hh3cPseProfilesEntry 3 }
|
|||
|
|
|||
|
hh3cPseProfilePowerLimit OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-create
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The power limit to be applied to the ports hh3cPsePortPowerLimit
|
|||
|
object when the profile is applied to the PSE port. Expressed in
|
|||
|
milliWatts."
|
|||
|
::= { hh3cPseProfilesEntry 4 }
|
|||
|
|
|||
|
hh3cPseProfilePriority OBJECT-TYPE
|
|||
|
SYNTAX INTEGER {
|
|||
|
critical(1),
|
|||
|
high(2),
|
|||
|
low(3)
|
|||
|
}
|
|||
|
MAX-ACCESS read-create
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This object controls the priority of the port from the point of
|
|||
|
view of a power management algorithm. The priority that is set
|
|||
|
by this variable could be used by a control mechanism that
|
|||
|
prevents over current situations by disconnecting first ports
|
|||
|
with lower power priority. Ports that connect devices critical
|
|||
|
to the operation of the network - like the E911 telephones
|
|||
|
ports - should be set to higher priority."
|
|||
|
::= { hh3cPseProfilesEntry 5 }
|
|||
|
|
|||
|
hh3cPseProfilePairs OBJECT-TYPE
|
|||
|
SYNTAX INTEGER {
|
|||
|
signal(1),
|
|||
|
spare(2)
|
|||
|
}
|
|||
|
MAX-ACCESS read-create
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Describes or controls the pairs in use. If the value of
|
|||
|
pethPsePortPowerPairsControl is true, this object is writable.
|
|||
|
A value of signal(1) means that the signal pairs only are in use.
|
|||
|
A value of spare(2) means that the spare pairs only are in use."
|
|||
|
REFERENCE
|
|||
|
"IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
|
|||
|
::= { hh3cPseProfilesEntry 6 }
|
|||
|
|
|||
|
hh3cPseProfileApplyNum OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The number of this profile which has been applied.
|
|||
|
If hh3cPseProfileApplyNum is not zero, user can't
|
|||
|
change the current line."
|
|||
|
::= { hh3cPseProfilesEntry 7 }
|
|||
|
|
|||
|
hh3cPseProfileRowStatus OBJECT-TYPE
|
|||
|
SYNTAX RowStatus
|
|||
|
MAX-ACCESS read-create
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The status of this classifier.
|
|||
|
If hh3cPseProfileApplyNum is not zero, user can't
|
|||
|
delete the current line."
|
|||
|
::= { hh3cPseProfilesEntry 8 }
|
|||
|
|
|||
|
hh3cPseAutoDetectActive OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
{
|
|||
|
notSupported(1),
|
|||
|
disabled(2),
|
|||
|
enabled(3)
|
|||
|
}
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies whether the device auto-detection feature is
|
|||
|
active. If this object is set to Active, and a known powered device
|
|||
|
is detected, then the port will automatically switch to Auto-Guaranteed
|
|||
|
mode. This is a stackwide object (ie. it is not referenced by
|
|||
|
group index)."
|
|||
|
::= { hh3cPowerEthernetExt 3 }
|
|||
|
|
|||
|
hh3cPsePowerMaxValue OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the max poe power for lanswitch.
|
|||
|
The value should between the power currently and the max power."
|
|||
|
::= { hh3cPowerEthernetExt 5 }
|
|||
|
|
|||
|
hh3cPsePolicyMode OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
{
|
|||
|
disabled(1),
|
|||
|
priority(2)
|
|||
|
}
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The PSE policy only applies to the situation that when a new
|
|||
|
board (PSE) is inserted, and the power is overload.
|
|||
|
A value of priority(2) means that the power will stop supplying
|
|||
|
to the low priority PSE. About PSE priority, please refer to
|
|||
|
hh3cMainPsePowerPriority. A value of disabled(1) means that the
|
|||
|
power will stop supplying to the new inserted PSE. The default
|
|||
|
value of this object is disabled(1)."
|
|||
|
::= { hh3cPowerEthernetExt 9 }
|
|||
|
|
|||
|
hh3cPDPolicyMode OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
{
|
|||
|
disabled(1),
|
|||
|
priority(2)
|
|||
|
}
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The PD policy only applies to the situation that when a new
|
|||
|
PD is inserted, and the power of PSE is overload.
|
|||
|
A value of priority(2) means that the power will stop supplying
|
|||
|
to the low priority port PD. About port priority, please refer
|
|||
|
to pethPsePortPowerPriority. A value of disabled(1) means that
|
|||
|
the slot stop supplying to the new inserted PD. The default
|
|||
|
value of this object is disabled(1)."
|
|||
|
::= { hh3cPowerEthernetExt 10 }
|
|||
|
|
|||
|
hh3cpseportNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 6 }
|
|||
|
|
|||
|
-- Notification Control Objects
|
|||
|
|
|||
|
hh3cpsePDChangeNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { pethPsePortDetectionStatus }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates if PD has been inserted or pulled out."
|
|||
|
::= { hh3cpseportNotification 1 }
|
|||
|
|
|||
|
hh3cPOEDisconnectNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleDisconnect }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module does not disconnect."
|
|||
|
::= { hh3cpseportNotification 2 }
|
|||
|
|
|||
|
hh3cPOEInputErrorNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleInputError }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module input error."
|
|||
|
::= { hh3cpseportNotification 3 }
|
|||
|
|
|||
|
hh3cPOEOutputErrorNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOutputError }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module output error."
|
|||
|
::= { hh3cpseportNotification 4 }
|
|||
|
|
|||
|
hh3cPOEOverVoltageNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverVoltage }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module overruns the
|
|||
|
voltage limit."
|
|||
|
::= { hh3cpseportNotification 5 }
|
|||
|
|
|||
|
hh3cPOEOverTempNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverTemp }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module overruns the
|
|||
|
temperature limit."
|
|||
|
::= { hh3cpseportNotification 6 }
|
|||
|
|
|||
|
hh3cPOEFanErrorNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleFanError }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module fan error."
|
|||
|
::= { hh3cpseportNotification 7 }
|
|||
|
|
|||
|
hh3cPOEModuleShutdownNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleShutdown }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module is closed."
|
|||
|
::= { hh3cpseportNotification 8 }
|
|||
|
|
|||
|
hh3cPOECurRestrictedNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleCurRestricted }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the POE power module current is restricted."
|
|||
|
::= { hh3cpseportNotification 9 }
|
|||
|
|
|||
|
hh3cPOEACSwitchNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEACSwitchStateIndex, hh3cPOEACSwitchState }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the AC input switch alarm of this POE power."
|
|||
|
::= { hh3cpseportNotification 10 }
|
|||
|
|
|||
|
hh3cPOEACInCurANotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEInCurAState }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the AC input current A alarm state of
|
|||
|
this POE power."
|
|||
|
::= { hh3cpseportNotification 11 }
|
|||
|
|
|||
|
hh3cPOEACInCurBNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEInCurBState }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the AC input current B alarm state of
|
|||
|
this POE power."
|
|||
|
::= { hh3cpseportNotification 12 }
|
|||
|
|
|||
|
hh3cPOEACInCurCNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEInCurCState }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the AC input current C alarm state of
|
|||
|
this POE power."
|
|||
|
::= { hh3cpseportNotification 13 }
|
|||
|
|
|||
|
hh3cPOEACSwitchVolABNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolAB}
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the AC input voltage AB alarm state of
|
|||
|
this POE power."
|
|||
|
::= { hh3cpseportNotification 14 }
|
|||
|
|
|||
|
hh3cPOEACSwitchVolBCNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolBC}
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the AC input voltage BC alarm state of
|
|||
|
this POE power."
|
|||
|
::= { hh3cpseportNotification 15 }
|
|||
|
|
|||
|
hh3cPOEACSwitchVolCANotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolCA }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the AC input voltage CA alarm state of
|
|||
|
this POE power."
|
|||
|
::= { hh3cpseportNotification 16 }
|
|||
|
|
|||
|
hh3cPOEDCOutVolNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS { hh3cPOEDCOutStateIndex, hh3cPOEDCOutDCVolAlarm }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the DC output alarm of this POE power."
|
|||
|
::= { hh3cpseportNotification 17 }
|
|||
|
|
|||
|
hh3cPOEShutdownNotification NOTIFICATION-TYPE
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This notification indicates the whole POE power has been shutdown."
|
|||
|
::= { hh3cpseportNotification 18 }
|
|||
|
hh3cPseComformance OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 4 }
|
|||
|
|
|||
|
hh3cPseCompliances OBJECT IDENTIFIER ::= { hh3cPseComformance 1 }
|
|||
|
|
|||
|
hh3cPseCompliance MODULE-COMPLIANCE
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Description."
|
|||
|
MODULE -- this module
|
|||
|
MANDATORY-GROUPS { hh3cPsePortGroup,
|
|||
|
hh3cMainPseGroup,
|
|||
|
hh3cPseScalarGroup,
|
|||
|
hh3cPsePDNotificationGroup
|
|||
|
}
|
|||
|
GROUP hh3cPseProfilesGroup
|
|||
|
DESCRIPTION
|
|||
|
"This group is mandatory only for executing POE commands as a batch."
|
|||
|
::= { hh3cPseCompliances 1 }
|
|||
|
|
|||
|
hh3cPseGroup OBJECT IDENTIFIER ::= { hh3cPseComformance 2 }
|
|||
|
|
|||
|
hh3cPsePortGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPsePortProfileIndex, hh3cPsePortPowerLimit, hh3cPsePortCurrentPower,
|
|||
|
hh3cPsePortAveragePower, hh3cPsePortPeakPower, hh3cPsePortFaultDescription,
|
|||
|
hh3cMainPsePriorityMode
|
|||
|
}
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"A collection of objects should be supported at the same time."
|
|||
|
::= { hh3cPseGroup 1 }
|
|||
|
|
|||
|
hh3cMainPseGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cMainPsePowerLimit, hh3cMainPseAveragePower, hh3cMainPsePeakPower,
|
|||
|
hh3cMainGuaranteedPowerRemaining }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"A collection of objects should be supported at the same time."
|
|||
|
::= { hh3cPseGroup 2 }
|
|||
|
|
|||
|
hh3cPseScalarGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPseAutoDetectActive, hh3cPsePowerMaxValue, hh3cPsePolicyMode ,
|
|||
|
hh3cPDPolicyMode }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"A collection of scalar objects supported."
|
|||
|
::= { hh3cPseGroup 3 }
|
|||
|
|
|||
|
hh3cPsePDNotificationGroup NOTIFICATION-GROUP
|
|||
|
NOTIFICATIONS { hh3cpsePDChangeNotification }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"PD Change Notification."
|
|||
|
::= { hh3cPseGroup 4 }
|
|||
|
|
|||
|
hh3cPseProfilesGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPseProfileName, hh3cPseProfilePowerMode,
|
|||
|
hh3cPseProfilePowerLimit, hh3cPseProfilePriority,
|
|||
|
hh3cPseProfilePairs, hh3cPseProfileApplyNum, hh3cPseProfileRowStatus}
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"A collection of objects should be supported at the same time."
|
|||
|
::= { hh3cPseGroup 5 }
|
|||
|
|
|||
|
hh3cPOEPowerThresholdLimitGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPOEThresholdACMimimum, hh3cPOEThresholdACMaximum,
|
|||
|
hh3cPOEThresholdDCMinimum, hh3cPOEThresholdDCMaximum }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Power threshold limits group."
|
|||
|
::= { hh3cPseGroup 6 }
|
|||
|
|
|||
|
hh3cPOEPowerSupInfoGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPOEPowerType, hh3cPOEPowerModuleNum, hh3cPOESupervisionModuleName,
|
|||
|
hh3cPOESMMajorVersion, hh3cPOESMMinorVersion, hh3cPOESMFactorName}
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The basic Power information group."
|
|||
|
::= { hh3cPseGroup 7 }
|
|||
|
|
|||
|
hh3cPOEPowerDCOutStateGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPOEDCOutStateModuleNum }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The DC out power state group."
|
|||
|
::= { hh3cPseGroup 8 }
|
|||
|
|
|||
|
hh3cPOEPowerDCOutInfoGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPOEDCOutCurNum }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The power AC input switch information group"
|
|||
|
::= { hh3cPseGroup 9 }
|
|||
|
|
|||
|
hh3cPOEPowerACSwitchStateModuleGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPOEACSwitchStateModuleNum}
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"PD Change Notification."
|
|||
|
::= { hh3cPseGroup 10 }
|
|||
|
|
|||
|
hh3cPOEPowerInCurStateGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPOEInCurStateModuleNum, hh3cPOEInCurAState, hh3cPOEInCurBState,
|
|||
|
hh3cPOEInCurCState}
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"PD Change Notification."
|
|||
|
::= { hh3cPseGroup 11 }
|
|||
|
|
|||
|
hh3cPOEPowerAlarmStateGroup OBJECT-GROUP
|
|||
|
OBJECTS { hh3cPOEAlarmStateModuleNum }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"PD Change Notification."
|
|||
|
::= { hh3cPseGroup 12 }
|
|||
|
|
|||
|
ACAlarmState ::= TEXTUAL-CONVENTION
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"AC Alarm State."
|
|||
|
SYNTAX INTEGER{
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)
|
|||
|
}
|
|||
|
|
|||
|
DCAlarmState ::= TEXTUAL-CONVENTION
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"DC Alarm State."
|
|||
|
SYNTAX INTEGER{
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
fuseBroken (4),
|
|||
|
switchOff (5),
|
|||
|
otherError (6)
|
|||
|
}
|
|||
|
|
|||
|
SwitchState ::= TEXTUAL-CONVENTION
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Switch State."
|
|||
|
SYNTAX INTEGER {
|
|||
|
on (1),
|
|||
|
off (2),
|
|||
|
highVoltInput (3),
|
|||
|
lowVoltInput (4)
|
|||
|
}
|
|||
|
|
|||
|
ModuleAlarmState ::= TEXTUAL-CONVENTION
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Module Alarm State."
|
|||
|
SYNTAX INTEGER {
|
|||
|
normal (1),
|
|||
|
alarm (2)
|
|||
|
}
|
|||
|
|
|||
|
hh3cPOEPowerObjects OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 8 }
|
|||
|
|
|||
|
hh3cPOEThresholdLimitObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 1 }
|
|||
|
|
|||
|
hh3cPOEThresholdACMimimum OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..10))
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Input threshold AC minimum.
|
|||
|
It is a read-write node.
|
|||
|
The value of this node is 'OCTET STRING',
|
|||
|
it is used to describe a float value.
|
|||
|
So this string should fit the following rule:
|
|||
|
1. This string should be terminated by '\0';
|
|||
|
2. Every characters should be number or radix point;
|
|||
|
3. The radix point should occur only once, and it should not
|
|||
|
be the first or the last character of the string.
|
|||
|
The value of this node should be smaller than 264.0V and larger than 90.0V.
|
|||
|
And it should be smaller than the hh3cPOEThresholdACMaximum."
|
|||
|
::= { hh3cPOEThresholdLimitObjs 1 }
|
|||
|
|
|||
|
hh3cPOEThresholdACMaximum OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..10))
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Input threshold AC maximum.
|
|||
|
It is a read-write node.
|
|||
|
The value of this node is 'OCTET STRING',
|
|||
|
it is used to describe a float value.
|
|||
|
So this string should fit the following rule:
|
|||
|
1. This string should be terminated by '\0';
|
|||
|
2. Every characters should be number or radix point;
|
|||
|
3. The radix point should occur only once, and it should not
|
|||
|
be the first or the last character of the string.
|
|||
|
It should be smaller than 264.0V and larger than 90.0V.
|
|||
|
And it should be larger than the hh3cPOEThresholdACMinimum."
|
|||
|
::= { hh3cPOEThresholdLimitObjs 2 }
|
|||
|
|
|||
|
hh3cPOEThresholdDCMinimum OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..10))
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Input threshold DC minimum.
|
|||
|
It is a read-write node.
|
|||
|
The value of this node is 'OCTET STRING',
|
|||
|
it is used to describe a float value.
|
|||
|
So this string should fit the following rule:
|
|||
|
1. This string should be terminated by '\0';
|
|||
|
2. Every characters should be number or radix point;
|
|||
|
3. The radix point should occur only once, and it should not
|
|||
|
be the first or the last character of the string.
|
|||
|
It should be smaller than 47.0V and larger than 45.0V."
|
|||
|
::= { hh3cPOEThresholdLimitObjs 3 }
|
|||
|
|
|||
|
hh3cPOEThresholdDCMaximum OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..10))
|
|||
|
MAX-ACCESS read-write
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Input threshold DC maximum.
|
|||
|
It is a read-write node.
|
|||
|
The value of this node is 'OCTET STRING',
|
|||
|
it is used to describe a float value.
|
|||
|
So this string should fit the following rule:
|
|||
|
1. This string should be terminated by '\0';
|
|||
|
2. Every characters should be number or radix point;
|
|||
|
3. The radix point should occur only once, and it should not
|
|||
|
be the first or the last character of the string.
|
|||
|
It should be smaller than 57.0V and larger than 55.0V."
|
|||
|
::= { hh3cPOEThresholdLimitObjs 4 }
|
|||
|
|
|||
|
hh3cPOESupModuleInfoObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 2 }
|
|||
|
|
|||
|
hh3cPOEPowerType OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..127))
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The type of the power."
|
|||
|
::= { hh3cPOESupModuleInfoObjs 1 }
|
|||
|
|
|||
|
hh3cPOEPowerModuleNum OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The number of the power modules."
|
|||
|
::= { hh3cPOESupModuleInfoObjs 2 }
|
|||
|
|
|||
|
hh3cPOESupervisionModuleName OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..127))
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the Supervision Module name on this POE power."
|
|||
|
::= { hh3cPOESupModuleInfoObjs 3 }
|
|||
|
|
|||
|
hh3cPOESMMajorVersion OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the high byte of the monitor module version."
|
|||
|
::= { hh3cPOESupModuleInfoObjs 4 }
|
|||
|
|
|||
|
hh3cPOESMMinorVersion OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the low byte of the monitor module version."
|
|||
|
::= { hh3cPOESupModuleInfoObjs 5 }
|
|||
|
|
|||
|
hh3cPOESMFactorName OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..127))
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the name of the manufactor."
|
|||
|
::= { hh3cPOESupModuleInfoObjs 6 }
|
|||
|
|
|||
|
hh3cPOEModuleInfoTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPOEModuleInfoEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The table of the module information on this POE power."
|
|||
|
::= { hh3cPOESupModuleInfoObjs 7 }
|
|||
|
|
|||
|
hh3cPOEModuleInfoEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPOEModuleInfoEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The entry of the module information on this POE power."
|
|||
|
INDEX { hh3cPOEModuleIndex }
|
|||
|
::= { hh3cPOEModuleInfoTable 1 }
|
|||
|
|
|||
|
Hh3cPOEModuleInfoEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cPOEModuleIndex
|
|||
|
Integer32,
|
|||
|
hh3cPOEModuleID
|
|||
|
Integer32,
|
|||
|
hh3cPOEModuleInfoPower
|
|||
|
Integer32,
|
|||
|
hh3cPOEModuleHardVerInfo
|
|||
|
OCTET STRING
|
|||
|
}
|
|||
|
|
|||
|
hh3cPOEModuleIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The index of the current module on this POE power.
|
|||
|
It is also the index of hh3cPOEModuleInfoTable.
|
|||
|
The range of this node is from 1 to hh3cPOEPowerModuleNum."
|
|||
|
::= { hh3cPOEModuleInfoEntry 1 }
|
|||
|
|
|||
|
hh3cPOEModuleID OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The ID of the current module on this POE power."
|
|||
|
::= { hh3cPOEModuleInfoEntry 2 }
|
|||
|
|
|||
|
hh3cPOEModuleInfoPower OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The power of the current module on this POE power."
|
|||
|
::= { hh3cPOEModuleInfoEntry 3 }
|
|||
|
|
|||
|
hh3cPOEModuleHardVerInfo OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..127))
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The hardware version information of the current module on this POE power."
|
|||
|
::= { hh3cPOEModuleInfoEntry 4 }
|
|||
|
|
|||
|
hh3cPOEDCOutStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 3 }
|
|||
|
|
|||
|
hh3cPOEDCOutStateModuleNum OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The module number on this POE power.
|
|||
|
It is the maximum of the hh3cPOEDCOutStateIndex."
|
|||
|
::= { hh3cPOEDCOutStateObjects 1 }
|
|||
|
|
|||
|
hh3cPOEDCOutStateTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPOEDCOutStateEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The table of DC output power state on this POE power."
|
|||
|
::= { hh3cPOEDCOutStateObjects 2 }
|
|||
|
|
|||
|
hh3cPOEDCOutStateEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPOEDCOutStateEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The entry of the DC output power state on this POE power."
|
|||
|
INDEX { hh3cPOEDCOutStateIndex }
|
|||
|
::= { hh3cPOEDCOutStateTable 1 }
|
|||
|
|
|||
|
Hh3cPOEDCOutStateEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cPOEDCOutStateIndex
|
|||
|
Integer32,
|
|||
|
hh3cPOEDCOutDCVolAlarm
|
|||
|
DCAlarmState
|
|||
|
}
|
|||
|
|
|||
|
hh3cPOEDCOutStateIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The index of the DC output power state on this POE power.
|
|||
|
The range of this node is from 1 to hh3cPOEDCOutStateModuleNum."
|
|||
|
::= { hh3cPOEDCOutStateEntry 1 }
|
|||
|
|
|||
|
hh3cPOEDCOutDCVolAlarm OBJECT-TYPE
|
|||
|
SYNTAX DCAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The DC output alarm of the DC output power state on this POE power.
|
|||
|
The value of this node will be the following values:
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
fuseBroken (4),
|
|||
|
switchOff (5),
|
|||
|
otherError (6)."
|
|||
|
::= { hh3cPOEDCOutStateEntry 2 }
|
|||
|
|
|||
|
hh3cPOEDCOutInfoObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 4 }
|
|||
|
|
|||
|
hh3cPOEDCOutCurNum OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The number of DC output current on this POE power.
|
|||
|
It is the maximum of hh3cPOEDCOutInfoIndex."
|
|||
|
::= { hh3cPOEDCOutInfoObjects 1 }
|
|||
|
|
|||
|
hh3cPOEDCOutInfoTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPOEDCOutInfoEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The table of the DC output information on this POE power."
|
|||
|
::= { hh3cPOEDCOutInfoObjects 2 }
|
|||
|
|
|||
|
hh3cPOEDCOutInfoEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPOEDCOutInfoEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The entry of the DC output information on this POE power."
|
|||
|
INDEX { hh3cPOEDCOutInfoIndex }
|
|||
|
::= { hh3cPOEDCOutInfoTable 1 }
|
|||
|
|
|||
|
Hh3cPOEDCOutInfoEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cPOEDCOutInfoIndex
|
|||
|
Integer32,
|
|||
|
hh3cPOEDCOutVol
|
|||
|
OCTET STRING,
|
|||
|
hh3cPOEDCOutInfoLoadCur
|
|||
|
OCTET STRING
|
|||
|
}
|
|||
|
|
|||
|
hh3cPOEDCOutInfoIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The index of the DC output information on this POE POWER.
|
|||
|
The range of this node is from 1 to hh3cPOEDCOutCurNum."
|
|||
|
::= { hh3cPOEDCOutInfoEntry 1 }
|
|||
|
|
|||
|
hh3cPOEDCOutVol OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..10))
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The DC output voltage of the current DC output on this POE power."
|
|||
|
::= { hh3cPOEDCOutInfoEntry 2 }
|
|||
|
|
|||
|
hh3cPOEDCOutInfoLoadCur OBJECT-TYPE
|
|||
|
SYNTAX OCTET STRING (SIZE (1..10))
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The total load current of the current DC output on this POE power."
|
|||
|
::= { hh3cPOEDCOutInfoEntry 3 }
|
|||
|
|
|||
|
hh3cPOEACSwitchStateModuleObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 5 }
|
|||
|
|
|||
|
hh3cPOEACSwitchStateModuleNum OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The number of the AC swtich state module on this POE power.
|
|||
|
It is the maximum of hh3cPOEACSwitchStateIndex."
|
|||
|
::= { hh3cPOEACSwitchStateModuleObjs 1 }
|
|||
|
|
|||
|
hh3cPOEACSwitchStateTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPOEACSwitchStateEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The table of the AC switch state on this POE power."
|
|||
|
::= { hh3cPOEACSwitchStateModuleObjs 2 }
|
|||
|
|
|||
|
hh3cPOEACSwitchStateEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPOEACSwitchStateEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The entry of the AC switch state on this POE power."
|
|||
|
INDEX { hh3cPOEACSwitchStateIndex }
|
|||
|
::= { hh3cPOEACSwitchStateTable 1 }
|
|||
|
|
|||
|
Hh3cPOEACSwitchStateEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cPOEACSwitchStateIndex
|
|||
|
Integer32,
|
|||
|
hh3cPOEACSwitchState
|
|||
|
SwitchState
|
|||
|
}
|
|||
|
|
|||
|
hh3cPOEACSwitchStateIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The index of the AC switch state on this POE power.
|
|||
|
The range of this node is from 1 to hh3cPOEACSwitchStateModuleNum."
|
|||
|
::= { hh3cPOEACSwitchStateEntry 1 }
|
|||
|
|
|||
|
hh3cPOEACSwitchState OBJECT-TYPE
|
|||
|
SYNTAX SwitchState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The AC switch state on this POE power.
|
|||
|
The value of this node will be one of the following values:
|
|||
|
on (1),
|
|||
|
off (2),
|
|||
|
highVoltInput (3),
|
|||
|
lowVoltInput (4)"
|
|||
|
::= { hh3cPOEACSwitchStateEntry 2 }
|
|||
|
|
|||
|
hh3cPOEInCurStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 6 }
|
|||
|
|
|||
|
hh3cPOEInCurStateModuleNum OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The DC input current state of the module on this POE power.
|
|||
|
It is the maximum of the hh3cPOESwitchStateVolExIndex."
|
|||
|
::= { hh3cPOEInCurStateObjects 1 }
|
|||
|
|
|||
|
hh3cPOEInCurAState OBJECT-TYPE
|
|||
|
SYNTAX ACAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The current A state in the DC input on this POE power.
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)."
|
|||
|
::= { hh3cPOEInCurStateObjects 2 }
|
|||
|
|
|||
|
hh3cPOEInCurBState OBJECT-TYPE
|
|||
|
SYNTAX ACAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The current B state in the DC input on this POE power.
|
|||
|
The value of this node will be one of the following values:
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)."
|
|||
|
::= { hh3cPOEInCurStateObjects 3 }
|
|||
|
|
|||
|
hh3cPOEInCurCState OBJECT-TYPE
|
|||
|
SYNTAX ACAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The current C state in the DC input on this POE power.
|
|||
|
The value of this node will be one of the following values:
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)."
|
|||
|
::= { hh3cPOEInCurStateObjects 4 }
|
|||
|
|
|||
|
hh3cPOESwitchStateVolExTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPOESwitchStateVolExEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"All alarm status of the VOL status.
|
|||
|
The value of this node will be one of the following values:
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)."
|
|||
|
::= { hh3cPOEInCurStateObjects 5 }
|
|||
|
|
|||
|
hh3cPOESwitchStateVolExEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPOESwitchStateVolExEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The hh3cPOESwitchStateVolExIndex will match the number of the VOL status."
|
|||
|
INDEX { hh3cPOESwitchStateVolExIndex }
|
|||
|
::= { hh3cPOESwitchStateVolExTable 1 }
|
|||
|
|
|||
|
Hh3cPOESwitchStateVolExEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cPOESwitchStateVolExIndex
|
|||
|
Integer32,
|
|||
|
hh3cPOESwitchStateInVolAB
|
|||
|
ACAlarmState,
|
|||
|
hh3cPOESwitchStateInVolBC
|
|||
|
ACAlarmState,
|
|||
|
hh3cPOESwitchStateInVolCA
|
|||
|
ACAlarmState
|
|||
|
}
|
|||
|
|
|||
|
hh3cPOESwitchStateVolExIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object species the index of the VOL status.
|
|||
|
The range of this node is from 1 to hh3cPOEInCurStateModuleNum."
|
|||
|
::= { hh3cPOESwitchStateVolExEntry 1 }
|
|||
|
|
|||
|
hh3cPOESwitchStateInVolAB OBJECT-TYPE
|
|||
|
SYNTAX ACAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the VOL AB alarm in each VOL status.
|
|||
|
The value of this node will be one of the following values:
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)."
|
|||
|
::= { hh3cPOESwitchStateVolExEntry 2 }
|
|||
|
|
|||
|
hh3cPOESwitchStateInVolBC OBJECT-TYPE
|
|||
|
SYNTAX ACAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the VOL BC alarm in each VOL status.
|
|||
|
The value of this node will be one of the following values:
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)."
|
|||
|
::= { hh3cPOESwitchStateVolExEntry 3 }
|
|||
|
|
|||
|
hh3cPOESwitchStateInVolCA OBJECT-TYPE
|
|||
|
SYNTAX ACAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the VOL CA alarm in each VOL status.
|
|||
|
The value of this node will be one of the following values:
|
|||
|
normal (1),
|
|||
|
underLimit (2),
|
|||
|
aboveLimit (3),
|
|||
|
lackPhrase (4),
|
|||
|
fuseBroken (5),
|
|||
|
switchOff (6),
|
|||
|
otherError (7)."
|
|||
|
::= { hh3cPOESwitchStateVolExEntry 4 }
|
|||
|
|
|||
|
hh3cPOEAlarmStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 7 }
|
|||
|
|
|||
|
hh3cPOEAlarmStateModuleNum OBJECT-TYPE
|
|||
|
SYNTAX Integer32
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The object specifies the number of the power modules in alarm state."
|
|||
|
::= { hh3cPOEAlarmStateObjects 1 }
|
|||
|
|
|||
|
hh3cPOEAlarmStateInfoTable OBJECT-TYPE
|
|||
|
SYNTAX SEQUENCE OF Hh3cPOEAlarmStateInfoEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"All alarm states in the POE power modules."
|
|||
|
::= { hh3cPOEAlarmStateObjects 2 }
|
|||
|
|
|||
|
hh3cPOEAlarmStateInfoEntry OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPOEAlarmStateInfoEntry
|
|||
|
MAX-ACCESS not-accessible
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The hh3cPOEAlarmModuleInfoIndex will match the number
|
|||
|
of the power module."
|
|||
|
INDEX { hh3cPOEAlarmModuleInfoIndex }
|
|||
|
::= { hh3cPOEAlarmStateInfoTable 1 }
|
|||
|
|
|||
|
Hh3cPOEAlarmStateInfoEntry ::=
|
|||
|
SEQUENCE {
|
|||
|
hh3cPOEAlarmModuleInfoIndex
|
|||
|
Integer32,
|
|||
|
hh3cPOEModuleDisconnect
|
|||
|
ModuleAlarmState,
|
|||
|
hh3cPOEModuleInputError
|
|||
|
ModuleAlarmState,
|
|||
|
hh3cPOEModuleOutputError
|
|||
|
ModuleAlarmState,
|
|||
|
hh3cPOEModuleOverVoltage
|
|||
|
ModuleAlarmState,
|
|||
|
hh3cPOEModuleOverTemp
|
|||
|
ModuleAlarmState,
|
|||
|
hh3cPOEModuleFanError
|
|||
|
ModuleAlarmState,
|
|||
|
hh3cPOEModuleShutdown
|
|||
|
ModuleAlarmState,
|
|||
|
hh3cPOEModuleCurRestricted
|
|||
|
ModuleAlarmState
|
|||
|
}
|
|||
|
|
|||
|
hh3cPOEAlarmModuleInfoIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The index specifies the index of the Hh3cPOEAlarmStateInfoEntry table.
|
|||
|
The range of this node is from 1 to hh3cPOEAlarmStateModuleNum."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 1 }
|
|||
|
|
|||
|
hh3cPOEModuleDisconnect OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
The module does not link.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 2 }
|
|||
|
|
|||
|
hh3cPOEModuleInputError OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
Input error.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 3 }
|
|||
|
|
|||
|
hh3cPOEModuleOutputError OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
Output error.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 4 }
|
|||
|
|
|||
|
hh3cPOEModuleOverVoltage OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
The voltage is too high.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 5 }
|
|||
|
|
|||
|
hh3cPOEModuleOverTemp OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
The temperature is too high.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 6 }
|
|||
|
|
|||
|
hh3cPOEModuleFanError OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
The fan error.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 7 }
|
|||
|
|
|||
|
hh3cPOEModuleShutdown OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
The module is shutdown.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 8 }
|
|||
|
|
|||
|
hh3cPOEModuleCurRestricted OBJECT-TYPE
|
|||
|
SYNTAX ModuleAlarmState
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The node specifies the alarm state:
|
|||
|
The module limit the current.
|
|||
|
The value of this node is one of the following values:
|
|||
|
normal (1),
|
|||
|
alarm (2)."
|
|||
|
::= { hh3cPOEAlarmStateInfoEntry 9 }
|
|||
|
|
|||
|
Hh3cPDDisableState ::= TEXTUAL-CONVENTION
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"PD disabled State."
|
|||
|
SYNTAX INTEGER{
|
|||
|
unknown(0),
|
|||
|
overInrush(1),
|
|||
|
lessMPSCurrent(2),
|
|||
|
peakPower(3),
|
|||
|
overVoltage(4),
|
|||
|
underVoltage(5),
|
|||
|
overTemperature(6),
|
|||
|
shortCircuit(7)
|
|||
|
}
|
|||
|
|
|||
|
hh3cPseNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 11 }
|
|||
|
hh3cPseNotificationPrefix OBJECT IDENTIFIER ::= { hh3cPseNotification 0 }
|
|||
|
|
|||
|
hh3cPsePDDisableNotification NOTIFICATION-TYPE
|
|||
|
OBJECTS{ hh3cPsePortGroupIndex, hh3cPsePortIndex, hh3cPsePortDisableInfo }
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"The PD has been powered off."
|
|||
|
::= { hh3cPseNotificationPrefix 1 }
|
|||
|
|
|||
|
hh3cPseNotificationObjects OBJECT IDENTIFIER ::= { hh3cPseNotification 1 }
|
|||
|
|
|||
|
hh3cPsePortGroupIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This variable uniquely identifies the group
|
|||
|
containing the port to which a power Ethernet PSE is
|
|||
|
connected."
|
|||
|
::= { hh3cPseNotificationObjects 1 }
|
|||
|
|
|||
|
hh3cPsePortIndex OBJECT-TYPE
|
|||
|
SYNTAX Integer32 (1..2147483647)
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"This variable uniquely identifies the power Ethernet PSE
|
|||
|
port within group pethPsePortGroupIndex to which the
|
|||
|
power Ethernet PSE entry is connected."
|
|||
|
::= { hh3cPseNotificationObjects 2 }
|
|||
|
|
|||
|
hh3cPsePortDisableInfo OBJECT-TYPE
|
|||
|
SYNTAX Hh3cPDDisableState
|
|||
|
MAX-ACCESS accessible-for-notify
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"
|
|||
|
Reason that caused PSE port power failure.
|
|||
|
The calue of this node is one of the following values:
|
|||
|
unknown(0),
|
|||
|
overInrush(1),
|
|||
|
lessMPSCurrent(2),
|
|||
|
peakPower(3),
|
|||
|
overVoltage(4),
|
|||
|
underVoltage(5),
|
|||
|
overTemperature(6),
|
|||
|
shortCircuit(7).
|
|||
|
"
|
|||
|
::= { hh3cPseNotificationObjects 3 }
|
|||
|
|
|||
|