mibs/MIBS/comware/HH3C-POWER-ETH-EXT-MIB
2023-12-05 12:25:34 +01:00

1611 lines
59 KiB
Plaintext

-- =================================================================
-- Copyright (c) 2004-2019 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: Power over ethernet extend MIB
-- Reference: POWER-ETHERNET-MIB
-- Version: V1.7
-- History:
-- V1.0 2004-07-24 Created by Gaolong
-- V1.1 2004-09-08 Update file by Gaolong for some syntax errors.
-- V1.2 2004-11-19 Update file by liuhongxu for poe need.
-- add hh3cMainPsePriorityMode¡¢hh3cPsePowerMaxValue¡¢
-- hh3cpsePDChangNotification adjust the objects' sequence of
-- hh3cPsePortTable and hh3cMainPseTable add the description
-- of MANDATORY-GROUPS in hh3cPseCompliance.
-- V1.3 2004-12-16 Update file by liuhongxu for poe profile
-- add hh3cPsePortProfile, hh3cPseProfilesTable
-- change the name of hh3cPseProfileIndex add
-- hh3cPseProfileApplyNum. adjust the format of this mib.
-- V1.4 2005-03-29 Update file by Wangzhaoyan for poe pow need.
-- add hh3cPOEPowerObjects, hh3cPOEThresholdLimitObjs,
-- hh3cPOESupModuleInfoObjs, hh3cPOEDCOutStateObjects,
-- hh3cPOEDCDCOutInfoObjects, hh3cPOEACSwitchStateModuleObjs,
-- hh3cPOEInCurStateObjects, hh3cPOEAlarmStateObjects and the
-- sub-nodes. add 17 traps change the node name from
-- hh3cpsePDChangNotification to hh3cpsePDChangeNotification
-- change some detail as the suggestion from Wangyingxia and
-- Yangyang. adjust the format of this mib.
-- V1.5 2005-11-21 Update file by Liweizhen for controling the power-management
-- policy of PSE or PD. Add hh3cPsePolicyMode, hh3cPDPolicyMode,
-- hh3cMainPsePowerPriority.
-- Delete some description of hh3cPsePortProfileIndex node.
-- Change the description of hh3cPseProfilePowerMode node.
-- Change SYNTAX OCTET STRING range for the following nodes:
-- hh3cPOEPowerType, hh3cPOESupervisionModuleName,
-- hh3cPOESMFactorName, hh3cPOEModuleHardVerInfo.
-- Adjust the format of this mib.
-- V1.6 2015-07-21 Update file by Fangliwen for profile power limit.
-- Change the syntax of hh3cPseProfilePowerLimit node.
-- V1.7 2019-5-23 Update file for PoE-AI. Add the following nodes:
-- hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
-- hh3cPsePortIndex and hh3cPsePortDisableInfo.
-- =================================================================
HH3C-POWER-ETH-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
hh3cCommon
FROM HH3C-OID-MIB
pethPsePortGroupIndex, pethPsePortIndex,
pethMainPseGroupIndex, pethPsePortDetectionStatus
FROM POWER-ETHERNET-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
hh3cPowerEthernetExt MODULE-IDENTITY
LAST-UPDATED "201905230000Z" -- May 23, 2019 at 00:00 GMT
ORGANIZATION
"New H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085
"
DESCRIPTION
"Description."
REVISION "201905230000Z"
DESCRIPTION
"Add the following nodes:
hh3cPsePDDisableNotification,hh3cPsePortGroupIndex,
hh3cPsePortIndex and hh3cPsePortDisableInfo."
REVISION "201507250000Z"
DESCRIPTION
"The initial version of this MIB module."
::= { hh3cCommon 14 }
--
-- Node definitions
--
hh3cPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The indexing scheme is taken form that used by
the IETF Power MIB. The same indexing scheme is
used to give continuity in behaviour between
that standard and this extensions definitioin."
::= { hh3cPowerEthernetExt 1 }
hh3cPsePortEntry OBJECT-TYPE
SYNTAX Hh3cPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The pethPsePortGroupIndex is imported from the IETF Power MIB
and uniquely identifies the group containing the port to which
power ethernet PSE is connected. Group means (box in the stack,
module in a rack).
The pethPsePortPowerIndex is imported from the IETF Power MIB
and uniquely identifies the power ethernet PSE port within group
pethPseGroupIndex to which the power Ethernet PSE entry is
connected. This value will match the local port number on a
switch."
INDEX { pethPsePortGroupIndex, pethPsePortIndex }
::= { hh3cPsePortTable 1 }
Hh3cPsePortEntry ::=
SEQUENCE {
hh3cPsePortFaultDescription
DisplayString,
hh3cPsePortPeakPower
Integer32,
hh3cPsePortAveragePower
Integer32,
hh3cPsePortCurrentPower
Integer32,
hh3cPsePortPowerLimit
Integer32,
hh3cPsePortProfileIndex
Integer32
}
hh3cPsePortFaultDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object supports the fault category of the IETF Power MIB [1]
pethPsePortDetectionStatus object. A textual description
containing more information about the nature of this fault is
provided by this object. Typically this will detail the precise
PoE hardware state which is causing the pethPsePortDetectionStatus
object to be in the 'fault' state.
It is a DisplayString of up to 255 characters."
::= { hh3cPsePortEntry 2 }
hh3cPsePortPeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the peak power which has been consumed by
the port. It is defined as the highest measured value of power
in milliWatts that has been consumed by the port. Its value
is only reset when link is lost, the port is PoE disabled or
when it is manually reset by the user asspecified below.
It is a read/write integer value with units of milliWatts.
Writing a value of zero to this object resets its value
to zero. Writing any other value to this object has no
effect on its value and an error is returned."
::= { hh3cPsePortEntry 3 }
hh3cPsePortAveragePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the average power which has been consumed
by the port. This object is a read/write integer value with
units of milliWatts. Writing a value of zero to this object
resets its value to zero. Writing any other value to this
object has no effect on its value and an error is returned."
::= { hh3cPsePortEntry 4 }
hh3cPsePortCurrentPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the power currently being consumed by the port.
It is a read only integer value with units of milliWatts."
::= { hh3cPsePortEntry 5 }
hh3cPsePortPowerLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the power limit set for this port.
The PSE will not supply more than this level of power to the
specified port.
It is a read/write integer value with units of milliWatts."
::= { hh3cPsePortEntry 6 }
hh3cPsePortProfileIndex OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the power profile which is currently associated
with this port. This object references the corresponding
hh3cPseProfileIndex object in the power profiles table. A
value of zero is a special case and indicates that no
power profile is currently associated with this port. When
hh3cPseProfileIndex is set to an index of existent profile,
pethPsePortPowerPairs, pethPsePortPowerPriority,
pethPsePortAdminEnable and hh3cPsePortPowerLimit will be
set to the same as corresponding value. PethPsePortPowerPairs,
pethPsePortPowerPriority and pethPsePortAdminEnable are objects
of rfc3621-Power-Ethernet.mib."
::= { hh3cPsePortEntry 7 }
hh3cMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { hh3cPowerEthernetExt 2 }
hh3cMainPseEntry OBJECT-TYPE
SYNTAX Hh3cMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The pethMainPseGroupIndex is imported from the IETF Power MIB
and uniquely identifies the group containing the port to which
power ethernet PSE is connected. Group means (box in the stack,
module in a rack) and the value 1 MUST be used for non-modular
devices."
INDEX { pethMainPseGroupIndex }
::= { hh3cMainPseTable 1 }
Hh3cMainPseEntry ::=
SEQUENCE {
hh3cMainPsePowerLimit
Integer32,
hh3cMainPseAveragePower
Integer32,
hh3cMainPsePeakPower
Integer32,
hh3cMainGuaranteedPowerRemaining
Integer32,
hh3cMainPsePriorityMode
INTEGER,
hh3cMainPseLegacy
INTEGER,
hh3cMainPsePowerPriority
INTEGER
}
hh3cMainPsePowerLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the power limit set for the unit as a whole.
The PoE unit will already have a nominal power defined by the
IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object
specifies a further limit to this nominal power value. This may
be useful to control the thermals of the unit, or for internal
testing purposes. One possible use for this object may be to lower
the power consumption of the unit if one or more of the internal
fans have broken. It is a read/write integer value with units of
Watts (note - Watts is chosen instead of milliWatts here since
the IETF Power MIB [1] measures unit based parameters, such as
the pethMainPsePower object, in units of Watts)."
::= { hh3cMainPseEntry 1 }
hh3cMainPseAveragePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the average power which has been consumed
by the port. It is a read/write integer value with units of
Watts (note - Watts is chosen instead of milliWatts here since
the IETF Power MIB [1] measures unit based parameters, such as
the pethMainPsePower object, in units of Watts). Writing a value
of zero to this object resets its value to zero. Writing any
other value to this object has no effect on its value and an error
is returned."
::= { hh3cMainPseEntry 2 }
hh3cMainPsePeakPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the peak power which has been consumed for PoE.
It is defined as the highest measured value of power in milliWatts
that has been consumed at any one point in time by the sum of the PoE
ports. Its value is only reset when the unit is powered on or when
it is manually reset by the user as specifiedbelow. It is a read/write
integer value with units of Watts (note - Watts is chosen instead of
milliWatts here since the IETF Power MIB [1] measures unit based
parameters, such as the pethMainPsePower object, in units of Watts).
Writing a value of zero to this object resets its value to zero.
Writing any other value to this object has noeffect on its value
and an error is returned."
::= { hh3cMainPseEntry 3 }
hh3cMainGuaranteedPowerRemaining OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the amount of power remaining in the guaranteed
power pool. Each time a port is placed into guaranteed mode it
reserves a set amount of power out of the total guaranteed power
pool for the system. This intention of this object is to give the
client of this MIB (whether that be the CLI or the Web interface or
the end user) an indication of how many ports can still be placed
into guaranteed mode. It is a read only integer value with units of
Watts(note - Watts is chosen instead of milliWatts here since the
IETF Power MIB [1] measures unit based parameters,such as the
pethMainPsePower object, in units of Watts)."
::= { hh3cMainPseEntry 4 }
hh3cMainPsePriorityMode OBJECT-TYPE
SYNTAX INTEGER {
disconnection(0),
non-disconnection(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the priority mode on slot which must be
enabled firstly. When a new board is inserted, and the power is
over-load, a value of disconnection(0) means that the power will
stop supply to the low priority slot ; A value of non-disconnection(1)
means that the slot still supply when a new board is inserted, and
the power is over-load too."
::= { hh3cMainPseEntry 5 }
hh3cMainPseLegacy OBJECT-TYPE
SYNTAX INTEGER {
enable(0),
disable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the legacy mode on slot which must be enabled
firstly. Legacy mode: standard or nonstandard PD detection mode."
::= { hh3cMainPseEntry 6 }
hh3cMainPsePowerPriority OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
high(2),
low(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the priority of the PSE. The priority
will be used by the PSE policy to prevent from power overloading.
If the priority of PSE is set to critical, the PSE will turn into
guaranteed mode. The priority could be used by a control mechanism
that prevents power overloading by disconnecting PSEs with lower
power priority. PSEs that connect devices critical to the
application should be set to higher priority."
::= { hh3cMainPseEntry 7 }
-- Power Profile PSE table
hh3cPseProfilesTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPseProfilesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects representing a set of power profiles.
Power profiles can be applied to PoE ports, which have the
effect of automatically setting the priority, power limit
and PoE enable MIB objects to the values specified in the
power profile."
::= { hh3cPowerEthernetExt 7 }
hh3cPseProfilesEntry OBJECT-TYPE
SYNTAX Hh3cPseProfilesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the Main power of a PSE."
INDEX { hh3cPseProfileIndex }
::= { hh3cPseProfilesTable 1 }
Hh3cPseProfilesEntry ::= SEQUENCE {
hh3cPseProfileIndex Integer32,
hh3cPseProfileName DisplayString,
hh3cPseProfilePowerMode INTEGER,
hh3cPseProfilePowerLimit Integer32,
hh3cPseProfilePriority INTEGER,
hh3cPseProfilePairs INTEGER,
hh3cPseProfileApplyNum Integer32,
hh3cPseProfileRowStatus RowStatus
}
hh3cPseProfileIndex OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the profile. This uniquely allow the profile to be
identified."
::= { hh3cPseProfilesEntry 1 }
hh3cPseProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..15))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Assigns the profile a name with which the settings
can be assiciated with. For example, 'NBX Phone'."
::= { hh3cPseProfilesEntry 2 }
hh3cPseProfilePowerMode OBJECT-TYPE
SYNTAX INTEGER {
powerDisabled (1),
powerEnabled (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The power mode associated with this power profile. There
are two possible power modes as follows: powerDisabled,
powerEnabled. When a power profile is applied to a PSE port,
this value dictates the settings of the ports pethPsePortPowerPriority
and pethPsePortAdminEnable objects."
::= { hh3cPseProfilesEntry 3 }
hh3cPseProfilePowerLimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The power limit to be applied to the ports hh3cPsePortPowerLimit
object when the profile is applied to the PSE port. Expressed in
milliWatts."
::= { hh3cPseProfilesEntry 4 }
hh3cPseProfilePriority OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
high(2),
low(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the priority of the port from the point of
view of a power management algorithm. The priority that is set
by this variable could be used by a control mechanism that
prevents over current situations by disconnecting first ports
with lower power priority. Ports that connect devices critical
to the operation of the network - like the E911 telephones
ports - should be set to higher priority."
::= { hh3cPseProfilesEntry 5 }
hh3cPseProfilePairs OBJECT-TYPE
SYNTAX INTEGER {
signal(1),
spare(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Describes or controls the pairs in use. If the value of
pethPsePortPowerPairsControl is true, this object is writable.
A value of signal(1) means that the signal pairs only are in use.
A value of spare(2) means that the spare pairs only are in use."
REFERENCE
"IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
::= { hh3cPseProfilesEntry 6 }
hh3cPseProfileApplyNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of this profile which has been applied.
If hh3cPseProfileApplyNum is not zero, user can't
change the current line."
::= { hh3cPseProfilesEntry 7 }
hh3cPseProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this classifier.
If hh3cPseProfileApplyNum is not zero, user can't
delete the current line."
::= { hh3cPseProfilesEntry 8 }
hh3cPseAutoDetectActive OBJECT-TYPE
SYNTAX INTEGER
{
notSupported(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies whether the device auto-detection feature is
active. If this object is set to Active, and a known powered device
is detected, then the port will automatically switch to Auto-Guaranteed
mode. This is a stackwide object (ie. it is not referenced by
group index)."
::= { hh3cPowerEthernetExt 3 }
hh3cPsePowerMaxValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the max poe power for lanswitch.
The value should between the power currently and the max power."
::= { hh3cPowerEthernetExt 5 }
hh3cPsePolicyMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
priority(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PSE policy only applies to the situation that when a new
board (PSE) is inserted, and the power is overload.
A value of priority(2) means that the power will stop supplying
to the low priority PSE. About PSE priority, please refer to
hh3cMainPsePowerPriority. A value of disabled(1) means that the
power will stop supplying to the new inserted PSE. The default
value of this object is disabled(1)."
::= { hh3cPowerEthernetExt 9 }
hh3cPDPolicyMode OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
priority(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PD policy only applies to the situation that when a new
PD is inserted, and the power of PSE is overload.
A value of priority(2) means that the power will stop supplying
to the low priority port PD. About port priority, please refer
to pethPsePortPowerPriority. A value of disabled(1) means that
the slot stop supplying to the new inserted PD. The default
value of this object is disabled(1)."
::= { hh3cPowerEthernetExt 10 }
hh3cpseportNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 6 }
-- Notification Control Objects
hh3cpsePDChangeNotification NOTIFICATION-TYPE
OBJECTS { pethPsePortDetectionStatus }
STATUS current
DESCRIPTION
"This notification indicates if PD has been inserted or pulled out."
::= { hh3cpseportNotification 1 }
hh3cPOEDisconnectNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleDisconnect }
STATUS current
DESCRIPTION
"This notification indicates the POE power module does not disconnect."
::= { hh3cpseportNotification 2 }
hh3cPOEInputErrorNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleInputError }
STATUS current
DESCRIPTION
"This notification indicates the POE power module input error."
::= { hh3cpseportNotification 3 }
hh3cPOEOutputErrorNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOutputError }
STATUS current
DESCRIPTION
"This notification indicates the POE power module output error."
::= { hh3cpseportNotification 4 }
hh3cPOEOverVoltageNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverVoltage }
STATUS current
DESCRIPTION
"This notification indicates the POE power module overruns the
voltage limit."
::= { hh3cpseportNotification 5 }
hh3cPOEOverTempNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleOverTemp }
STATUS current
DESCRIPTION
"This notification indicates the POE power module overruns the
temperature limit."
::= { hh3cpseportNotification 6 }
hh3cPOEFanErrorNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleFanError }
STATUS current
DESCRIPTION
"This notification indicates the POE power module fan error."
::= { hh3cpseportNotification 7 }
hh3cPOEModuleShutdownNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleShutdown }
STATUS current
DESCRIPTION
"This notification indicates the POE power module is closed."
::= { hh3cpseportNotification 8 }
hh3cPOECurRestrictedNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEAlarmModuleInfoIndex, hh3cPOEModuleCurRestricted }
STATUS current
DESCRIPTION
"This notification indicates the POE power module current is restricted."
::= { hh3cpseportNotification 9 }
hh3cPOEACSwitchNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEACSwitchStateIndex, hh3cPOEACSwitchState }
STATUS current
DESCRIPTION
"This notification indicates the AC input switch alarm of this POE power."
::= { hh3cpseportNotification 10 }
hh3cPOEACInCurANotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEInCurAState }
STATUS current
DESCRIPTION
"This notification indicates the AC input current A alarm state of
this POE power."
::= { hh3cpseportNotification 11 }
hh3cPOEACInCurBNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEInCurBState }
STATUS current
DESCRIPTION
"This notification indicates the AC input current B alarm state of
this POE power."
::= { hh3cpseportNotification 12 }
hh3cPOEACInCurCNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEInCurCState }
STATUS current
DESCRIPTION
"This notification indicates the AC input current C alarm state of
this POE power."
::= { hh3cpseportNotification 13 }
hh3cPOEACSwitchVolABNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolAB}
STATUS current
DESCRIPTION
"This notification indicates the AC input voltage AB alarm state of
this POE power."
::= { hh3cpseportNotification 14 }
hh3cPOEACSwitchVolBCNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolBC}
STATUS current
DESCRIPTION
"This notification indicates the AC input voltage BC alarm state of
this POE power."
::= { hh3cpseportNotification 15 }
hh3cPOEACSwitchVolCANotification NOTIFICATION-TYPE
OBJECTS { hh3cPOESwitchStateVolExIndex, hh3cPOESwitchStateInVolCA }
STATUS current
DESCRIPTION
"This notification indicates the AC input voltage CA alarm state of
this POE power."
::= { hh3cpseportNotification 16 }
hh3cPOEDCOutVolNotification NOTIFICATION-TYPE
OBJECTS { hh3cPOEDCOutStateIndex, hh3cPOEDCOutDCVolAlarm }
STATUS current
DESCRIPTION
"This notification indicates the DC output alarm of this POE power."
::= { hh3cpseportNotification 17 }
hh3cPOEShutdownNotification NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This notification indicates the whole POE power has been shutdown."
::= { hh3cpseportNotification 18 }
hh3cPseComformance OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 4 }
hh3cPseCompliances OBJECT IDENTIFIER ::= { hh3cPseComformance 1 }
hh3cPseCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Description."
MODULE -- this module
MANDATORY-GROUPS { hh3cPsePortGroup,
hh3cMainPseGroup,
hh3cPseScalarGroup,
hh3cPsePDNotificationGroup
}
GROUP hh3cPseProfilesGroup
DESCRIPTION
"This group is mandatory only for executing POE commands as a batch."
::= { hh3cPseCompliances 1 }
hh3cPseGroup OBJECT IDENTIFIER ::= { hh3cPseComformance 2 }
hh3cPsePortGroup OBJECT-GROUP
OBJECTS { hh3cPsePortProfileIndex, hh3cPsePortPowerLimit, hh3cPsePortCurrentPower,
hh3cPsePortAveragePower, hh3cPsePortPeakPower, hh3cPsePortFaultDescription,
hh3cMainPsePriorityMode
}
STATUS current
DESCRIPTION
"A collection of objects should be supported at the same time."
::= { hh3cPseGroup 1 }
hh3cMainPseGroup OBJECT-GROUP
OBJECTS { hh3cMainPsePowerLimit, hh3cMainPseAveragePower, hh3cMainPsePeakPower,
hh3cMainGuaranteedPowerRemaining }
STATUS current
DESCRIPTION
"A collection of objects should be supported at the same time."
::= { hh3cPseGroup 2 }
hh3cPseScalarGroup OBJECT-GROUP
OBJECTS { hh3cPseAutoDetectActive, hh3cPsePowerMaxValue, hh3cPsePolicyMode ,
hh3cPDPolicyMode }
STATUS current
DESCRIPTION
"A collection of scalar objects supported."
::= { hh3cPseGroup 3 }
hh3cPsePDNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { hh3cpsePDChangeNotification }
STATUS current
DESCRIPTION
"PD Change Notification."
::= { hh3cPseGroup 4 }
hh3cPseProfilesGroup OBJECT-GROUP
OBJECTS { hh3cPseProfileName, hh3cPseProfilePowerMode,
hh3cPseProfilePowerLimit, hh3cPseProfilePriority,
hh3cPseProfilePairs, hh3cPseProfileApplyNum, hh3cPseProfileRowStatus}
STATUS current
DESCRIPTION
"A collection of objects should be supported at the same time."
::= { hh3cPseGroup 5 }
hh3cPOEPowerThresholdLimitGroup OBJECT-GROUP
OBJECTS { hh3cPOEThresholdACMimimum, hh3cPOEThresholdACMaximum,
hh3cPOEThresholdDCMinimum, hh3cPOEThresholdDCMaximum }
STATUS current
DESCRIPTION
"Power threshold limits group."
::= { hh3cPseGroup 6 }
hh3cPOEPowerSupInfoGroup OBJECT-GROUP
OBJECTS { hh3cPOEPowerType, hh3cPOEPowerModuleNum, hh3cPOESupervisionModuleName,
hh3cPOESMMajorVersion, hh3cPOESMMinorVersion, hh3cPOESMFactorName}
STATUS current
DESCRIPTION
"The basic Power information group."
::= { hh3cPseGroup 7 }
hh3cPOEPowerDCOutStateGroup OBJECT-GROUP
OBJECTS { hh3cPOEDCOutStateModuleNum }
STATUS current
DESCRIPTION
"The DC out power state group."
::= { hh3cPseGroup 8 }
hh3cPOEPowerDCOutInfoGroup OBJECT-GROUP
OBJECTS { hh3cPOEDCOutCurNum }
STATUS current
DESCRIPTION
"The power AC input switch information group"
::= { hh3cPseGroup 9 }
hh3cPOEPowerACSwitchStateModuleGroup OBJECT-GROUP
OBJECTS { hh3cPOEACSwitchStateModuleNum}
STATUS current
DESCRIPTION
"PD Change Notification."
::= { hh3cPseGroup 10 }
hh3cPOEPowerInCurStateGroup OBJECT-GROUP
OBJECTS { hh3cPOEInCurStateModuleNum, hh3cPOEInCurAState, hh3cPOEInCurBState,
hh3cPOEInCurCState}
STATUS current
DESCRIPTION
"PD Change Notification."
::= { hh3cPseGroup 11 }
hh3cPOEPowerAlarmStateGroup OBJECT-GROUP
OBJECTS { hh3cPOEAlarmStateModuleNum }
STATUS current
DESCRIPTION
"PD Change Notification."
::= { hh3cPseGroup 12 }
ACAlarmState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"AC Alarm State."
SYNTAX INTEGER{
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)
}
DCAlarmState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"DC Alarm State."
SYNTAX INTEGER{
normal (1),
underLimit (2),
aboveLimit (3),
fuseBroken (4),
switchOff (5),
otherError (6)
}
SwitchState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Switch State."
SYNTAX INTEGER {
on (1),
off (2),
highVoltInput (3),
lowVoltInput (4)
}
ModuleAlarmState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Module Alarm State."
SYNTAX INTEGER {
normal (1),
alarm (2)
}
hh3cPOEPowerObjects OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 8 }
hh3cPOEThresholdLimitObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 1 }
hh3cPOEThresholdACMimimum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold AC minimum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
The value of this node should be smaller than 264.0V and larger than 90.0V.
And it should be smaller than the hh3cPOEThresholdACMaximum."
::= { hh3cPOEThresholdLimitObjs 1 }
hh3cPOEThresholdACMaximum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold AC maximum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
It should be smaller than 264.0V and larger than 90.0V.
And it should be larger than the hh3cPOEThresholdACMinimum."
::= { hh3cPOEThresholdLimitObjs 2 }
hh3cPOEThresholdDCMinimum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold DC minimum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
It should be smaller than 47.0V and larger than 45.0V."
::= { hh3cPOEThresholdLimitObjs 3 }
hh3cPOEThresholdDCMaximum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input threshold DC maximum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
It should be smaller than 57.0V and larger than 55.0V."
::= { hh3cPOEThresholdLimitObjs 4 }
hh3cPOESupModuleInfoObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 2 }
hh3cPOEPowerType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the power."
::= { hh3cPOESupModuleInfoObjs 1 }
hh3cPOEPowerModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the power modules."
::= { hh3cPOESupModuleInfoObjs 2 }
hh3cPOESupervisionModuleName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the Supervision Module name on this POE power."
::= { hh3cPOESupModuleInfoObjs 3 }
hh3cPOESMMajorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the high byte of the monitor module version."
::= { hh3cPOESupModuleInfoObjs 4 }
hh3cPOESMMinorVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the low byte of the monitor module version."
::= { hh3cPOESupModuleInfoObjs 5 }
hh3cPOESMFactorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the name of the manufactor."
::= { hh3cPOESupModuleInfoObjs 6 }
hh3cPOEModuleInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPOEModuleInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of the module information on this POE power."
::= { hh3cPOESupModuleInfoObjs 7 }
hh3cPOEModuleInfoEntry OBJECT-TYPE
SYNTAX Hh3cPOEModuleInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the module information on this POE power."
INDEX { hh3cPOEModuleIndex }
::= { hh3cPOEModuleInfoTable 1 }
Hh3cPOEModuleInfoEntry ::=
SEQUENCE {
hh3cPOEModuleIndex
Integer32,
hh3cPOEModuleID
Integer32,
hh3cPOEModuleInfoPower
Integer32,
hh3cPOEModuleHardVerInfo
OCTET STRING
}
hh3cPOEModuleIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the current module on this POE power.
It is also the index of hh3cPOEModuleInfoTable.
The range of this node is from 1 to hh3cPOEPowerModuleNum."
::= { hh3cPOEModuleInfoEntry 1 }
hh3cPOEModuleID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the current module on this POE power."
::= { hh3cPOEModuleInfoEntry 2 }
hh3cPOEModuleInfoPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power of the current module on this POE power."
::= { hh3cPOEModuleInfoEntry 3 }
hh3cPOEModuleHardVerInfo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware version information of the current module on this POE power."
::= { hh3cPOEModuleInfoEntry 4 }
hh3cPOEDCOutStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 3 }
hh3cPOEDCOutStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module number on this POE power.
It is the maximum of the hh3cPOEDCOutStateIndex."
::= { hh3cPOEDCOutStateObjects 1 }
hh3cPOEDCOutStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPOEDCOutStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of DC output power state on this POE power."
::= { hh3cPOEDCOutStateObjects 2 }
hh3cPOEDCOutStateEntry OBJECT-TYPE
SYNTAX Hh3cPOEDCOutStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the DC output power state on this POE power."
INDEX { hh3cPOEDCOutStateIndex }
::= { hh3cPOEDCOutStateTable 1 }
Hh3cPOEDCOutStateEntry ::=
SEQUENCE {
hh3cPOEDCOutStateIndex
Integer32,
hh3cPOEDCOutDCVolAlarm
DCAlarmState
}
hh3cPOEDCOutStateIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the DC output power state on this POE power.
The range of this node is from 1 to hh3cPOEDCOutStateModuleNum."
::= { hh3cPOEDCOutStateEntry 1 }
hh3cPOEDCOutDCVolAlarm OBJECT-TYPE
SYNTAX DCAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DC output alarm of the DC output power state on this POE power.
The value of this node will be the following values:
normal (1),
underLimit (2),
aboveLimit (3),
fuseBroken (4),
switchOff (5),
otherError (6)."
::= { hh3cPOEDCOutStateEntry 2 }
hh3cPOEDCOutInfoObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 4 }
hh3cPOEDCOutCurNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DC output current on this POE power.
It is the maximum of hh3cPOEDCOutInfoIndex."
::= { hh3cPOEDCOutInfoObjects 1 }
hh3cPOEDCOutInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPOEDCOutInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of the DC output information on this POE power."
::= { hh3cPOEDCOutInfoObjects 2 }
hh3cPOEDCOutInfoEntry OBJECT-TYPE
SYNTAX Hh3cPOEDCOutInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the DC output information on this POE power."
INDEX { hh3cPOEDCOutInfoIndex }
::= { hh3cPOEDCOutInfoTable 1 }
Hh3cPOEDCOutInfoEntry ::=
SEQUENCE {
hh3cPOEDCOutInfoIndex
Integer32,
hh3cPOEDCOutVol
OCTET STRING,
hh3cPOEDCOutInfoLoadCur
OCTET STRING
}
hh3cPOEDCOutInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the DC output information on this POE POWER.
The range of this node is from 1 to hh3cPOEDCOutCurNum."
::= { hh3cPOEDCOutInfoEntry 1 }
hh3cPOEDCOutVol OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DC output voltage of the current DC output on this POE power."
::= { hh3cPOEDCOutInfoEntry 2 }
hh3cPOEDCOutInfoLoadCur OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total load current of the current DC output on this POE power."
::= { hh3cPOEDCOutInfoEntry 3 }
hh3cPOEACSwitchStateModuleObjs OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 5 }
hh3cPOEACSwitchStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the AC swtich state module on this POE power.
It is the maximum of hh3cPOEACSwitchStateIndex."
::= { hh3cPOEACSwitchStateModuleObjs 1 }
hh3cPOEACSwitchStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPOEACSwitchStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of the AC switch state on this POE power."
::= { hh3cPOEACSwitchStateModuleObjs 2 }
hh3cPOEACSwitchStateEntry OBJECT-TYPE
SYNTAX Hh3cPOEACSwitchStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the AC switch state on this POE power."
INDEX { hh3cPOEACSwitchStateIndex }
::= { hh3cPOEACSwitchStateTable 1 }
Hh3cPOEACSwitchStateEntry ::=
SEQUENCE {
hh3cPOEACSwitchStateIndex
Integer32,
hh3cPOEACSwitchState
SwitchState
}
hh3cPOEACSwitchStateIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index of the AC switch state on this POE power.
The range of this node is from 1 to hh3cPOEACSwitchStateModuleNum."
::= { hh3cPOEACSwitchStateEntry 1 }
hh3cPOEACSwitchState OBJECT-TYPE
SYNTAX SwitchState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The AC switch state on this POE power.
The value of this node will be one of the following values:
on (1),
off (2),
highVoltInput (3),
lowVoltInput (4)"
::= { hh3cPOEACSwitchStateEntry 2 }
hh3cPOEInCurStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 6 }
hh3cPOEInCurStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DC input current state of the module on this POE power.
It is the maximum of the hh3cPOESwitchStateVolExIndex."
::= { hh3cPOEInCurStateObjects 1 }
hh3cPOEInCurAState OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current A state in the DC input on this POE power.
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { hh3cPOEInCurStateObjects 2 }
hh3cPOEInCurBState OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current B state in the DC input on this POE power.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { hh3cPOEInCurStateObjects 3 }
hh3cPOEInCurCState OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current C state in the DC input on this POE power.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { hh3cPOEInCurStateObjects 4 }
hh3cPOESwitchStateVolExTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPOESwitchStateVolExEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All alarm status of the VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { hh3cPOEInCurStateObjects 5 }
hh3cPOESwitchStateVolExEntry OBJECT-TYPE
SYNTAX Hh3cPOESwitchStateVolExEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The hh3cPOESwitchStateVolExIndex will match the number of the VOL status."
INDEX { hh3cPOESwitchStateVolExIndex }
::= { hh3cPOESwitchStateVolExTable 1 }
Hh3cPOESwitchStateVolExEntry ::=
SEQUENCE {
hh3cPOESwitchStateVolExIndex
Integer32,
hh3cPOESwitchStateInVolAB
ACAlarmState,
hh3cPOESwitchStateInVolBC
ACAlarmState,
hh3cPOESwitchStateInVolCA
ACAlarmState
}
hh3cPOESwitchStateVolExIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The object species the index of the VOL status.
The range of this node is from 1 to hh3cPOEInCurStateModuleNum."
::= { hh3cPOESwitchStateVolExEntry 1 }
hh3cPOESwitchStateInVolAB OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the VOL AB alarm in each VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { hh3cPOESwitchStateVolExEntry 2 }
hh3cPOESwitchStateInVolBC OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the VOL BC alarm in each VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { hh3cPOESwitchStateVolExEntry 3 }
hh3cPOESwitchStateInVolCA OBJECT-TYPE
SYNTAX ACAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the VOL CA alarm in each VOL status.
The value of this node will be one of the following values:
normal (1),
underLimit (2),
aboveLimit (3),
lackPhrase (4),
fuseBroken (5),
switchOff (6),
otherError (7)."
::= { hh3cPOESwitchStateVolExEntry 4 }
hh3cPOEAlarmStateObjects OBJECT IDENTIFIER ::= { hh3cPOEPowerObjects 7 }
hh3cPOEAlarmStateModuleNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object specifies the number of the power modules in alarm state."
::= { hh3cPOEAlarmStateObjects 1 }
hh3cPOEAlarmStateInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cPOEAlarmStateInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All alarm states in the POE power modules."
::= { hh3cPOEAlarmStateObjects 2 }
hh3cPOEAlarmStateInfoEntry OBJECT-TYPE
SYNTAX Hh3cPOEAlarmStateInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The hh3cPOEAlarmModuleInfoIndex will match the number
of the power module."
INDEX { hh3cPOEAlarmModuleInfoIndex }
::= { hh3cPOEAlarmStateInfoTable 1 }
Hh3cPOEAlarmStateInfoEntry ::=
SEQUENCE {
hh3cPOEAlarmModuleInfoIndex
Integer32,
hh3cPOEModuleDisconnect
ModuleAlarmState,
hh3cPOEModuleInputError
ModuleAlarmState,
hh3cPOEModuleOutputError
ModuleAlarmState,
hh3cPOEModuleOverVoltage
ModuleAlarmState,
hh3cPOEModuleOverTemp
ModuleAlarmState,
hh3cPOEModuleFanError
ModuleAlarmState,
hh3cPOEModuleShutdown
ModuleAlarmState,
hh3cPOEModuleCurRestricted
ModuleAlarmState
}
hh3cPOEAlarmModuleInfoIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The index specifies the index of the Hh3cPOEAlarmStateInfoEntry table.
The range of this node is from 1 to hh3cPOEAlarmStateModuleNum."
::= { hh3cPOEAlarmStateInfoEntry 1 }
hh3cPOEModuleDisconnect OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The module does not link.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 2 }
hh3cPOEModuleInputError OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
Input error.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 3 }
hh3cPOEModuleOutputError OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
Output error.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 4 }
hh3cPOEModuleOverVoltage OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The voltage is too high.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 5 }
hh3cPOEModuleOverTemp OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The temperature is too high.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 6 }
hh3cPOEModuleFanError OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The fan error.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 7 }
hh3cPOEModuleShutdown OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The module is shutdown.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 8 }
hh3cPOEModuleCurRestricted OBJECT-TYPE
SYNTAX ModuleAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node specifies the alarm state:
The module limit the current.
The value of this node is one of the following values:
normal (1),
alarm (2)."
::= { hh3cPOEAlarmStateInfoEntry 9 }
Hh3cPDDisableState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"PD disabled State."
SYNTAX INTEGER{
unknown(0),
overInrush(1),
lessMPSCurrent(2),
peakPower(3),
overVoltage(4),
underVoltage(5),
overTemperature(6),
shortCircuit(7)
}
hh3cPseNotification OBJECT IDENTIFIER ::= { hh3cPowerEthernetExt 11 }
hh3cPseNotificationPrefix OBJECT IDENTIFIER ::= { hh3cPseNotification 0 }
hh3cPsePDDisableNotification NOTIFICATION-TYPE
OBJECTS{ hh3cPsePortGroupIndex, hh3cPsePortIndex, hh3cPsePortDisableInfo }
STATUS current
DESCRIPTION
"The PD has been powered off."
::= { hh3cPseNotificationPrefix 1 }
hh3cPseNotificationObjects OBJECT IDENTIFIER ::= { hh3cPseNotification 1 }
hh3cPsePortGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected."
::= { hh3cPseNotificationObjects 1 }
hh3cPsePortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This variable uniquely identifies the power Ethernet PSE
port within group pethPsePortGroupIndex to which the
power Ethernet PSE entry is connected."
::= { hh3cPseNotificationObjects 2 }
hh3cPsePortDisableInfo OBJECT-TYPE
SYNTAX Hh3cPDDisableState
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"
Reason that caused PSE port power failure.
The calue of this node is one of the following values:
unknown(0),
overInrush(1),
lessMPSCurrent(2),
peakPower(3),
overVoltage(4),
underVoltage(5),
overTemperature(6),
shortCircuit(7).
"
::= { hh3cPseNotificationObjects 3 }
END