-- DLINKSW-SFLOW-MIB.mib : D-Link sFlow MIB
--
-- Copyright (c) 2013 D-Link Corporation, all rights reserved.
--
-- *****************************************************************
DLINKSW-SFLOW-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus,DisplayString
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
InetAddressType, InetAddress, InetAddressIPv4, InetAddressIPv6
FROM INET-ADDRESS-MIB
dlinkIndustrialCommon
FROM DLINK-ID-REC-MIB;
dlinkSwSFlowMIB MODULE-IDENTITY
LAST-UPDATED "201304100000Z"
ORGANIZATION "D-Link Corp."
CONTACT-INFO
" D-Link Corporation
Postal: No. 289, Sinhu 3rd Rd., Neihu District,
Taipei City 114, Taiwan, R.O.C
Tel: +886-2-66000123
E-mail: tsd@dlink.com.tw
"
DESCRIPTION
"The structure of sFlow for the proprietary enterprise."
REVISION "201304100000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { dlinkIndustrialCommon 36 }
-- -----------------------------------------------------------------------------
dSFlowMIBNotifications OBJECT IDENTIFIER ::= { dlinkSwSFlowMIB 0 }
dSFlowMIBObjects OBJECT IDENTIFIER ::= { dlinkSwSFlowMIB 1 }
dSFlowMIBConformance OBJECT IDENTIFIER ::= { dlinkSwSFlowMIB 2 }
-- -----------------------------------------------------------------------------
DSFlowDataSource ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Identifies the ifIndex of interface as the source of sFlow data.
DSFlowDataSources of this traditional form are called
'port-based'. Ideally the sampling entity will perform
sampling on all flows originating from or destined to
the specified interface. However, if the switch architecture
only allows input or output sampling then the sampling agent
is permitted to only sample input flows input or output flows.
Each packet must only be considered once for sampling,
irrespective of the number of ports it will be forwarded to.
Note: Since each DSFlowDataSource operates independently a
packet that crosses multiple DataSources may generate
multiple flow records."
SYNTAX Integer32 (1..2147483647)
DSFlowInstance ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"If more than one sFlow sampler is available for this
DSFlowDataSource then individual samplers are distinguished
using the DSFlowInstance variable. The value of
DSFlowInstance ranges from 1..n where n is the number of
samplers associated with this DSFlowDataSource.
Note: Each sFlow sampler instance must operate
independently of all other instances. Setting
an attribute of one sampler must not alter the
the behavior and settings of other sampler
instances."
SYNTAX Integer32 (1..65535)
DSFlowReceiver ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Identify the sFlow receiver associated with this resource.
A value of zero indicates that this resource is available.
If non-zero the value must correspond to a valid, active
dSFlowRcvrIndex.
If the value is currently zero it may be set to any
active entry in the dSFlowRcvrTable. If the value is
not zero then a set to anything other than zero or
its current value will result in an SNMP error (bad value).
Setting to zero frees the resource and returns all the
values in this entry to their default values.
If an entry in the dSFlowRcvrTable expires, either
because the dSFlowRcvrOwner is set to the empty
string or because the dSFlowRcvrCurrentTimeout reaches zero, then
the agent must mark all associated resources as available
(by setting the associated DSFlowReceiver entry to zero)
and all values in these records must be restored to their
default values.
This mechanism provides no enforcement and relies on the
cooperation of management entities in order to ensure that
competition for a resource is fairly resolved. A management
entity should not make any changes to a resource
without first acquiring it by successfully writing its
dSFlowRcvrIndex value as the DSFlowReceiver for the resource."
SYNTAX Integer32
-- -----------------------------------------------------------------------------
dSFlowVersion OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Uniquely identifies the version and implementation of this MIB.
The version string must have the following structure:
<MIB Version>;<Organization>;<Software Revision>
where:
<MIB Version> must be '1.3', the version of referred SFLOW-MIB,
which is defined by sFlow.org.
<Organization> the name of the organization responsible
for the agent implementation.
<Revision> the specific software build of this agent.
As an example, the string '1.3;InMon Corp.;2.1.1' indicates
that this agent implements version '1.2' of the SFLOW MIB, that
it was developed by 'InMon Corp.' and that the software build
is '2.1.1'.
The MIB Version will change with each revision of the SFLOW-MIB.
Management entities must check the MIB Version and not attempt
to manage agents with MIB Versions greater than that for which
they were designed.
Note: The sFlow Datagram Format has an independent version
number which may change independently from <MIB Version>.
<MIB Version> applies to the structure and semantics of
the SFLOW MIB only."
DEFVAL { "1.3;;" }
::= { dSFlowMIBObjects 1 }
dSFlowAgentAddressIPv4 OBJECT-TYPE
SYNTAX InetAddressIPv4
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv4 address associated with this agent."
::= { dSFlowMIBObjects 2 }
dSFlowAgentAddressIPv6 OBJECT-TYPE
SYNTAX InetAddressIPv6
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv6 address associated with this agent. If the IPv6
is not supported on this agent, 0::0 will be displayed."
::= { dSFlowMIBObjects 3 }
-- -----------------------------------------------------------------------------
-- Receiver Table
-- -----------------------------------------------------------------------------
dSFlowRcvrTable OBJECT-TYPE
SYNTAX SEQUENCE OF DSFlowRcvrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the receivers of sFlow information."
::= { dSFlowMIBObjects 4 }
dSFlowRcvrEntry OBJECT-TYPE
SYNTAX DSFlowRcvrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of an sFlow Receiver."
INDEX { dSFlowRcvrIndex }
::= { dSFlowRcvrTable 1 }
DSFlowRcvrEntry ::= SEQUENCE {
dSFlowRcvrIndex Integer32,
dSFlowRcvrOwner DisplayString,
dSFlowRcvrAdminTimeout Integer32,
dSFlowRcvrCurrentTimeout Integer32,
dSFlowRcvrMaximumDatagramSize Integer32,
dSFlowRcvrAddressType InetAddressType,
dSFlowRcvrAddress InetAddress,
dSFlowRcvrVrfName DisplayString,
dSFlowRcvrPort Integer32,
dSFlowRcvrDatagramVersion Integer32,
dSFlowRcvrReset INTEGER
}
dSFlowRcvrIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into dSFlowReceiverTable. The number of supported receivers
is project dependent."
::= { dSFlowRcvrEntry 1 }
dSFlowRcvrOwner OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entity making use of this dSFlowRcvrTable entry. The
empty string indicates that the entry is currently unclaimed.
An entity wishing to claim a dSFlowRcvrTable entry must
ensure that the entry is unclaimed before trying to claim it.
The entry is claimed by setting the owner string. The entry
must be claimed before any changes can be made to the receiver's
other objects.
When a management entity is finished using the receiver, it
should set the value of dSFlowRcvrOwner back to unclaimed.
The agent must restore all other entities this row to their
default values when the owner is set to unclaimed. It must
also free all other resources associated with this
dSFlowRcvrTable entry.
This mechanism provides no enforcement and relies on the
cooperation of management entities in order to ensure that
competition for a receiver entry is fairly resolved."
DEFVAL { "" }
::= { dSFlowRcvrEntry 2 }
dSFlowRcvrAdminTimeout OBJECT-TYPE
SYNTAX Integer32 (0..2000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The expire time (in seconds) configured for the receiver.
A management entity wanting to maintain control of the receiver
is responsible for setting a new value before the old one
expires.
When the interval expires, the agent is responsible for
restoring all other entities in this row to their default
values. It must also free all other resources associated with
this dSFlowRcvrTable entry.
When set, 0 means infinite that the receiver will never be
expired."
DEFVAL { 0 }
::= { dSFlowRcvrEntry 3 }
dSFlowRcvrCurrentTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (in seconds) remaining before the receiver is released."
DEFVAL { 0 }
::= { dSFlowRcvrEntry 4 }
dSFlowRcvrMaximumDatagramSize OBJECT-TYPE
SYNTAX Integer32 (700..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of data bytes that can be sent in a single
sample datagram. The manager should set this value to avoid
fragmentation of the sFlow datagrams."
DEFVAL { 1400 }
::= { dSFlowRcvrEntry 5 }
dSFlowRcvrAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address type of the sFlow collector."
DEFVAL { ipv4 }
::= { dSFlowRcvrEntry 6 }
dSFlowRcvrAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the sFlow collector.
If set to 0.0.0.0 no sFlow datagrams will be sent."
DEFVAL { '00000000'h } -- 0.0.0.0
::= { dSFlowRcvrEntry 7 }
dSFlowRcvrVrfName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the name of the routing forwarding instance."
DEFVAL { "" }
::= { dSFlowRcvrEntry 8 }
dSFlowRcvrPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port of the remote sFlow collector."
DEFVAL { 6343 }
::= { dSFlowRcvrEntry 9 }
dSFlowRcvrDatagramVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of sFlow datagrams that should be sent."
DEFVAL { 5 }
::= { dSFlowRcvrEntry 10 }
dSFlowRcvrReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
noOp(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object reset the receiver when set to 'reset'.
No action is taken if this object is set to 'noOp'.
When read, the value 'noOp' is returned."
DEFVAL { noOp }
::= { dSFlowRcvrEntry 11 }
-- -----------------------------------------------------------------------------
-- Flow Sampling Table
-- -----------------------------------------------------------------------------
dSFlowFsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DSFlowFsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the flow samplers within a device."
::= { dSFlowMIBObjects 5 }
dSFlowFsEntry OBJECT-TYPE
SYNTAX DSFlowFsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a flow sampler."
INDEX {
dSFlowFsDataSource,
dSFlowFsInstance
}
::= { dSFlowFsTable 1 }
DSFlowFsEntry ::= SEQUENCE {
dSFlowFsDataSource DSFlowDataSource,
dSFlowFsInstance DSFlowInstance,
dSFlowFsReceiver DSFlowReceiver,
dSFlowFsDirection INTEGER,
dSFlowFsAdminSamplingRate Integer32,
dSFlowFsActiveSamplingRate Integer32,
dSFlowFsMaximumHeaderSize Integer32,
dSFlowFsRowStatus RowStatus
}
dSFlowFsDataSource OBJECT-TYPE
SYNTAX DSFlowDataSource
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the source of the data for this flow
sampler."
::= { dSFlowFsEntry 1 }
dSFlowFsInstance OBJECT-TYPE
SYNTAX DSFlowInstance
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The instance index for uniquely identifying the flow sampler
when multiple flow samplers are associated with one interface."
::= { dSFlowFsEntry 2 }
dSFlowFsReceiver OBJECT-TYPE
SYNTAX DSFlowReceiver
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of the sFlow receiver for this flow sampler."
DEFVAL { 0 }
::= { dSFlowFsEntry 3 }
dSFlowFsDirection OBJECT-TYPE
SYNTAX INTEGER{
inbound(1),
outbound(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the flow direction which will be sampled.
'inbound' - sample ingress packets.
'outbound' - sample egress packets."
DEFVAL { inbound }
::= { dSFlowFsEntry 4 }
dSFlowFsAdminSamplingRate OBJECT-TYPE
SYNTAX Integer32 (0..65536)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The configured sampling rate for packet sampling from this
source.
Set to N to sample 1/Nth of the packets in the monitored flows.
An agent should choose its own algorithm to introduce variance
into the sampling so that exactly every Nth packet is not
counted. A sampling rate of 1 counts all packets. A sampling
rate of 0 disables sampling.
The agent is permitted to have minimum and maximum allowable
values for the sampling rate. A minimum rate lets the agent
designer set an upper bound on the overhead associated with
sampling, and a maximum rate may be the result of hardware
restrictions (such as counter size). In addition not all values
between the maximum and minimum may be realizable as the
sampling rate (again because of implementation considerations).
When the sampling rate is set the agent is free to adjust the
value so that it lies between the maximum and minimum values
and has the closest achievable value.
When read, the configured sampling rate will be returned."
DEFVAL { 0 }
::= { dSFlowFsEntry 5 }
dSFlowFsActiveSamplingRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statistical sampling rate for packet sampling from this
source.
When read, the agent must return the actual sampling rate it
will be using (after the adjustments previously described). The
sampling algorithm must converge so that over time the number
of packets sampled approaches 1/Nth of the total number of
packets in the monitored flows."
DEFVAL { 0 }
::= { dSFlowFsEntry 6 }
dSFlowFsMaximumHeaderSize OBJECT-TYPE
SYNTAX Integer32 (18..256)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of bytes that should be copied from a
sampled packet. The agent may have an internal maximum and
minimum permissible sizes. If an attempt is made to set this
value outside the permissible range then the agent should
adjust the value to the closest permissible value."
DEFVAL { 128 }
::= { dSFlowFsEntry 7 }
dSFlowFsRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { dSFlowFsEntry 8 }
-- -----------------------------------------------------------------------------
-- Counter Polling Table
-- -----------------------------------------------------------------------------
dSFlowCpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DSFlowCpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the counter pollers within a device."
::= { dSFlowMIBObjects 6 }
dSFlowCpEntry OBJECT-TYPE
SYNTAX DSFlowCpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a counter poller."
INDEX {
dSFlowCpDataSource,
dSFlowCpInstance
}
::= { dSFlowCpTable 1 }
DSFlowCpEntry ::= SEQUENCE {
dSFlowCpDataSource DSFlowDataSource,
dSFlowCpInstance DSFlowInstance,
dSFlowCpReceiver DSFlowReceiver,
dSFlowCpInterval Integer32,
dSFlowCpRowStatus RowStatus
}
dSFlowCpDataSource OBJECT-TYPE
SYNTAX DSFlowDataSource
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies the source of the data for the counter poller."
::= { dSFlowCpEntry 1 }
dSFlowCpInstance OBJECT-TYPE
SYNTAX DSFlowInstance
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The instance instance index for uniquely identifying the counter
poller when multiple Pollers are associated with one interface."
::= { dSFlowCpEntry 2 }
dSFlowCpReceiver OBJECT-TYPE
SYNTAX DSFlowReceiver
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The sflow receiver's index for this counter poller."
DEFVAL { 0 }
::= { dSFlowCpEntry 3 }
dSFlowCpInterval OBJECT-TYPE
SYNTAX Integer32 (0..120)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of seconds between successive samples of the
counters associated with this data source. A sampling interval
of 0 disables counter sampling.
The agent is permitted to have minimum and maximum allowable
values for the counter polling interval. A minimum interval
lets the agent designer set an upper bound on the overhead
associated with polling, and a maximum interval may be the
result of implementation restrictions (such as counter size).
In addition not all values between the maximum and minimum may
be realizable as the sampling interval (again because of
implementation considerations)."
DEFVAL { 0 }
::= { dSFlowCpEntry 4 }
dSFlowCpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the status of this entry."
::= { dSFlowCpEntry 5 }
-- -----------------------------------------------------------------------------
-- MIB Conformance statements
-- -----------------------------------------------------------------------------
dSFlowMIBCompliances OBJECT IDENTIFIER ::= { dSFlowMIBConformance 1 }
dSFlowMIBGroups OBJECT IDENTIFIER ::= { dSFlowMIBConformance 2 }
dSFlowCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement the
DLINKSW-SFLOW-MIB."
MODULE -- this module
MANDATORY-GROUPS { dSFlowAgentGroup }
OBJECT dSFlowRcvrAddressType
DESCRIPTION
"It is compliant to support only a subset of values. For example if
the platform doesn't support IPv6, the type of 'ipv6' cannot be
configured."
OBJECT dSFlowRcvrVrfName
DESCRIPTION
"When the agent doesn't support VRF, only zero string can be set."
::= { dSFlowMIBCompliances 1 }
dSFlowAgentGroup OBJECT-GROUP
OBJECTS {
dSFlowVersion, dSFlowAgentAddressIPv4, dSFlowAgentAddressIPv6,
dSFlowRcvrOwner,dSFlowRcvrAdminTimeout,dSFlowRcvrCurrentTimeout,
dSFlowRcvrMaximumDatagramSize, dSFlowRcvrAddressType,
dSFlowRcvrAddress, dSFlowRcvrPort, dSFlowRcvrVrfName,
dSFlowRcvrDatagramVersion, dSFlowRcvrReset,
dSFlowFsReceiver, dSFlowFsDirection,
dSFlowFsAdminSamplingRate, dSFlowFsActiveSamplingRate,
dSFlowFsMaximumHeaderSize, dSFlowFsRowStatus,
dSFlowCpReceiver, dSFlowCpInterval, dSFlowCpRowStatus
}
STATUS current
DESCRIPTION
"A collection of objects for managing the generation and
transportation of sFlow data records."
::= { dSFlowMIBGroups 1 }
END