165 lines
5.0 KiB
Plaintext
165 lines
5.0 KiB
Plaintext
|
-- %DNP% $Id: RBN-TC.my,v 1.1.2.8.252.3 2011/02/22 17:26:18 thatcher Exp $
|
||
|
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/RBN-TC.my,v $
|
||
|
-- *****************************************************************
|
||
|
-- RBN-TC Textual Convention MIB
|
||
|
--
|
||
|
-- Copyright (c) 2000, 2002-2009, 2011 Ericsson AB
|
||
|
-- All rights reserved.
|
||
|
--
|
||
|
-- *****************************************************************
|
||
|
|
||
|
RBN-TC DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY,
|
||
|
Integer32, Unsigned32
|
||
|
FROM SNMPv2-SMI
|
||
|
|
||
|
TEXTUAL-CONVENTION
|
||
|
FROM SNMPv2-TC
|
||
|
|
||
|
rbnModules
|
||
|
FROM RBN-SMI;
|
||
|
|
||
|
|
||
|
rbnTC MODULE-IDENTITY
|
||
|
LAST-UPDATED "201101191800Z" -- Jan 19, 2011
|
||
|
ORGANIZATION "Ericsson AB."
|
||
|
CONTACT-INFO
|
||
|
" Ericsson AB.
|
||
|
|
||
|
Postal: 100 Headquarters Dr
|
||
|
San Jose, CA 95134
|
||
|
USA
|
||
|
|
||
|
Phone: +1 408 750 5000
|
||
|
Fax: +1 408 750 5599
|
||
|
"
|
||
|
DESCRIPTION
|
||
|
"Defines common textual conventions used in RBN mib
|
||
|
modules."
|
||
|
|
||
|
REVISION "201101191800Z" -- Jan 19, 2011
|
||
|
DESCRIPTION
|
||
|
"Update CONTACT-INFO & ORGANIZATION. "
|
||
|
|
||
|
REVISION "200910201700Z" -- Oct 20, 2009
|
||
|
DESCRIPTION
|
||
|
"Added new textual convention: RbnUnsigned64 for read-write
|
||
|
capable 64 bit integer value."
|
||
|
|
||
|
REVISION "200406191700Z" -- June 19, 2004
|
||
|
DESCRIPTION
|
||
|
"Added new textual convention: RbnPortMediumType. Correct
|
||
|
warnings given by smilint."
|
||
|
|
||
|
REVISION "200303171700Z" -- March 17, 2003
|
||
|
DESCRIPTION
|
||
|
"Added new textual convention: RbnVidOrUntagged."
|
||
|
|
||
|
REVISION "200211110000Z" -- November 11, 2002
|
||
|
DESCRIPTION
|
||
|
"Moved definitions of RbnSlot and RbnPort from RBN-PVC-MIB.
|
||
|
Updated range on RbnSlot and RbnPort."
|
||
|
|
||
|
REVISION "200206260000Z" -- June 26, 2002
|
||
|
DESCRIPTION
|
||
|
"Updated CONTACT-INFO. Added new textual conventions:
|
||
|
RbnKBytes and RbnPercentage."
|
||
|
|
||
|
REVISION "200007140000Z" -- July 14, 2000
|
||
|
DESCRIPTION
|
||
|
"Initial version."
|
||
|
::= { rbnModules 2 }
|
||
|
|
||
|
|
||
|
RbnCircuitHandle ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "1d:1d:2x-2x-2x"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique identifier for individual circuits. The string is
|
||
|
composed of the following:
|
||
|
|
||
|
Octet 1 slot
|
||
|
2 port
|
||
|
3-8 circuit identifier
|
||
|
|
||
|
slots/ports are numbered 0..n. The SMS CLI also numbers slots/ports
|
||
|
0..n but SE CLI numbers slots/ports 1..n. For example: When the
|
||
|
SE CLI refers to slot/port 1/2, this maps to to the RbnCircuitHandle
|
||
|
slot/port 0/1
|
||
|
"
|
||
|
SYNTAX OCTET STRING (SIZE (8))
|
||
|
|
||
|
RbnKBytes ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Storage size, expressed in units of 1024 bytes."
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
|
||
|
RbnPercentage ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d%"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This Textual Convention describes an object that stores
|
||
|
a whole integer percentage value."
|
||
|
SYNTAX Integer32 (0..100)
|
||
|
|
||
|
RbnSlot ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The chassis slot number. This is the physical slot
|
||
|
number as reported in the CLI command 'show hardware'
|
||
|
on SMS and the CLI command 'show port' on SE."
|
||
|
SYNTAX Unsigned32 (0..255)
|
||
|
|
||
|
RbnPort ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The chassis port number. This is the physical port
|
||
|
number as reported in the CLI command 'show hardware'
|
||
|
on SMS and the CLI command 'show port' on SE."
|
||
|
SYNTAX Unsigned32 (0..255)
|
||
|
|
||
|
RbnVidOrUntagged ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The twelve-bit VLAN Identifer (VID) used to uniquely
|
||
|
identify the VLAN to which the frame belongs. The VID is
|
||
|
encoded as an unsigned binary number. An untagged frame
|
||
|
does not carry any identification of the VLAN to which it
|
||
|
belongs and is designated with a value of 4096."
|
||
|
SYNTAX Integer32 (1..4096)
|
||
|
|
||
|
RbnPortMediumType ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Medium type of NAS port."
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(0),
|
||
|
dsl(11),
|
||
|
cable(12),
|
||
|
wireless(13),
|
||
|
satellite(14)
|
||
|
}
|
||
|
|
||
|
RbnUnsigned64 ::= TEXTUAL-CONVENTION
|
||
|
DISPLAY-HINT "8d"
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Unsigned 64 bit integer value is represented as an
|
||
|
OCTET STRING. This allows an unsigned integer value in
|
||
|
the range 0..18446744073709551615.
|
||
|
|
||
|
The octets are ordered with the first octet containing
|
||
|
the highest ordered bits of the integer and the 8th octet
|
||
|
containing the lowest ordered bits, corresponding to
|
||
|
network byte order."
|
||
|
SYNTAX OCTET STRING (SIZE(8))
|
||
|
|
||
|
END
|