HP-ICF-BRIDGE DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32
FROM SNMPv2-SMI
TruthValue, TimeStamp, TimeInterval
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
dot1dBasePortEntry
FROM BRIDGE-MIB
VlanIndex
FROM Q-BRIDGE-MIB
hpSwitch
FROM HP-ICF-OID
ConfigStatus
FROM HP-ICF-TC
hpSwitchStpPortEntry
FROM CONFIG-MIB
ifIndex
FROM IF-MIB
portCopyEntry
FROM SMON-MIB;
BridgeId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The Bridge Identifier as used in the Spanning Tree
Protocol to uniquely identify a bridge."
SYNTAX OCTET STRING (SIZE (8))
hpicfBridge MODULE-IDENTITY
LAST-UPDATED "200609300000Z" -- September 30, 2006
ORGANIZATION "Hewlett-Packard Company
Network Infrastructure Solutions"
CONTACT-INFO "Hewlett-Packard Company
8000 Foothills Blvd.
Roseville, CA 95747"
DESCRIPTION "This MIB module contains HP proprietary
extensions to the standard Bridge MIBs."
REVISION "200609300000Z" -- September 30, 2006
DESCRIPTION "Added 'hpicfBridgeMirrorSessionID' MIB object."
REVISION "200609260000Z" -- September 26, 2006
DESCRIPTION "Added 'hpicfBridgeRstpAutoEdgePort' MIB object."
REVISION "200608131738Z" -- Aug 08, 2006
DESCRIPTION "Added hpicfLoopProtect MIB and
updated conformance statements."
REVISION "200302200000Z" -- February 20, 2003
DESCRIPTION
"Added 'mstpOperation' option to the
'hpicfBridgeRstpForceVersion' MIB object.
Added 'ieee8021s' option to the
'hpicfBridgeRstpProtocolVersion' MIB object."
REVISION "200205231738Z" -- May 23, 2002
DESCRIPTION "Added conformance information."
REVISION "200110032050Z" -- October 3, 2001
DESCRIPTION "Modified hpicfBridgeRstp MIB to contain
ConfigStatus."
REVISION "200011030642Z" -- November 3, 2000
DESCRIPTION "Initial revision."
::= { hpSwitch 12 }
hpicfBridgeObjects
OBJECT IDENTIFIER ::= { hpicfBridge 1 }
hpicfBridgeBase
OBJECT IDENTIFIER ::= { hpicfBridgeObjects 1 }
-- **********************************************************************
-- VLAN Objects
-- **********************************************************************
hpicfBridgeMaxVlans OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Defines the number of VLANs that the switch will
support for dynamic use without requiring a reboot."
::= { hpicfBridgeBase 1 }
hpicfBridgeVlanEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Administrative status of VLAN support on this
switch."
::= { hpicfBridgeBase 2 }
hpicfBridgePrimaryVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The 802.1Q VLAN ID of the primary VLAN for this
switch."
::= { hpicfBridgeBase 3 }
hpicfBridgeVlanConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If one or more variables in this group has been
reconfigured since the last reboot in such a way
as to require a reboot to take effect, the value
of this variable will be set to 'notInService'."
::= { hpicfBridgeBase 4 }
-- **********************************************************************
-- GVRP Objects
-- **********************************************************************
hpicfBridgeGvrp OBJECT IDENTIFIER ::= { hpicfBridgeObjects 2 }
hpicfBridgeGvrpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfBridgeGvrpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table that contains information about the
GVRP port configurations on this switch."
::= { hpicfBridgeGvrp 1 }
hpicfBridgeGvrpPortEntry OBJECT-TYPE
SYNTAX HpicfBridgeGvrpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "GVRP information associated with a single port."
AUGMENTS { dot1dBasePortEntry }
::= { hpicfBridgeGvrpPortTable 1 }
HpicfBridgeGvrpPortEntry ::=
SEQUENCE {
hpicfBridgeGvrpRestrictedVlanReg TruthValue
}
hpicfBridgeGvrpRestrictedVlanReg OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls GVRP's ability to learn new VLANs on
this port. When set to 'false', GVRP will accept
JOIN requests for new VLANs on this port. When
set to 'true', GVRP will only process protocol
packets that concern themselves with known VLANs."
::= { hpicfBridgeGvrpPortEntry 1 }
-- **********************************************************************
-- Rapid Reconfiguration Spanning Tree Objects
-- **********************************************************************
hpicfBridgeRstp OBJECT IDENTIFIER ::= { hpicfBridgeObjects 4 }
hpicfBridgeRstpForceVersion OBJECT-TYPE
SYNTAX INTEGER {
stpCompatibility(0),
rstpOperation(2),
mstpOperation(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Operational mode of Spanning Tree protocol:
- stpCompatibility means protocol operates as STP protocol
on all ports.
- rstpOperation means protocol operates as Rapid
Reconfiguration on all ports except on those ports where
legacy system has been detected.
- mstpOperation means protocol operates in native MSTP mode,
this option is available only if object
'hpicfBridgeRstpProtocolVersion' is set to 'ieee8021s'."
::= { hpicfBridgeRstp 1 }
hpicfBridgeRstpConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The configuration status of this group of objects. If
one or more variables in this group were
reconfigured since last reboot and required reboot to
take effect, the value of this variable will be set to
notInService."
::= { hpicfBridgeRstp 2 }
hpicfBridgeRstpProtocolVersion OBJECT-TYPE
SYNTAX INTEGER {
ieee8021d(0),
ieee8021w(2),
ieee8021s(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The protocol version currently running on switch
- ieee8021d version of STP protocol,
- ieee8021w Rapid Reconfiguration version of STP protocol,
- ieee8021s Multiple STP (MSTP) protocol"
::= { hpicfBridgeRstp 3 }
hpicfBridgeRstpAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The operational status of the spanning tree protocol"
::= { hpicfBridgeRstp 4 }
hpicfBridgeRstpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfBridgeRstpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table that contains port-specific information
for the Spanning Tree Protocol."
::= { hpicfBridgeRstp 5 }
hpicfBridgeRstpPortEntry OBJECT-TYPE
SYNTAX HpicfBridgeRstpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of information maintained by every port
about the Spanning Tree Protocol state for that
port."
INDEX { hpicfBridgeRstpPortIndex }
::= { hpicfBridgeRstpPortTable 1 }
HpicfBridgeRstpPortEntry ::=
SEQUENCE {
hpicfBridgeRstpPortIndex INTEGER,
hpicfBridgeRstpAdminEdgePort INTEGER,
hpicfBridgeRstpOperEdgePort INTEGER,
hpicfBridgeRstpAdminPointToPointMac INTEGER,
hpicfBridgeRstpOperPointToPointMac TruthValue,
hpicfBridgeRstpPortPathCost INTEGER,
hpicfBridgeRstpForceBpduMigrationCheck TruthValue,
hpicfBridgeRstpAutoEdgePort TruthValue,
hpicfBridgeRstpPortBpduFiltering TruthValue
}
hpicfBridgeRstpPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The port number of the port for which this entry
contains Spanning Tree Protocol management
information."
REFERENCE
"IEEE 802.1w"
::= { hpicfBridgeRstpPortEntry 1 }
hpicfBridgeRstpAdminEdgePort OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate that port is connected to LAN segment that don't
have any bridge connected to it"
REFERENCE
"IEEE P802.1w Clause 17.3; IEEE P802.1t Clause 18"
::= { hpicfBridgeRstpPortEntry 2 }
hpicfBridgeRstpOperEdgePort OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Reflects the value of the operEdgePort parameter, as
defined by the operation of the Bridge Detection state
machine (Clause 18 of P802.1t). The value of this parameter
is used by a Designated Port in order to determine how
rapidly it may transition to the Forwarding Port State
(see 17.23, Port Role Transitions state machine).
The Bridge Detection state machine sets this parameter to
the value of adminEdgePort (P802.1t 18.1.3) on
initialization, and forces its value to FALSE if any BPDUs
are received on the Port."
REFERENCE
"IEEE P802.1w Clause 17.3; IEEE P802.1t Clause 18"
::= { hpicfBridgeRstpPortEntry 3 }
hpicfBridgeRstpAdminPointToPointMac OBJECT-TYPE
SYNTAX INTEGER {
forceTrue(1),
forceFalse(2),
auto(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "
forceTrue: This value indicates that the administrator requires the MAC
to be treated as if it is connected to a point-to-point LAN
segment, regardless of any indications to the contrary that
are generated by the MAC entity.
forceFalse: This value indicates that the administrator requires the MAC
to be treated as if it is connected to a non-point-to-point
LAN segment, regardless of any indications to the contrary
that are generated by the MAC entity.
auto: This value indicates that the administrator requires the
point-to-point status of the MAC to be determined in accordance
with the specific MAC procedures defined in 6.5."
REFERENCE
"IEEE P802.1w; IEEE P802.1t"
::= { hpicfBridgeRstpPortEntry 4 }
hpicfBridgeRstpOperPointToPointMac OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
true: This value indicates that the MAC is connected to a
point-to-point LAN segment; i.e., there is at most one other
system attached to the LAN segment.
false: This value indicates that the MAC is connected to a
non-point-to-point LAN segment; i.e., there can be more than one
other system attached to the LAN segment."
REFERENCE
"IEEE P802.1w; IEEE P802.1t"
::= { hpicfBridgeRstpPortEntry 5 }
hpicfBridgeRstpPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..200000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Rapid Reconfiguration Port Path Cost - 32 bit values"
REFERENCE
"IEEE 802.1w"
::= { hpicfBridgeRstpPortEntry 6 }
hpicfBridgeRstpForceBpduMigrationCheck OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When operating in RST (version 2 or greater) mode
writing TRUE(1) to this object forces this port to
transmit RST BPDUs. Any other operation on this object
has no effect and it always returns FALSE(2) when read."
REFERENCE
"IEEE P802.1w"
::= { hpicfBridgeRstpPortEntry 7 }
hpicfBridgeRstpAutoEdgePort OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Represents the value of 'autoEdgePort' parameter.
This parameter is optional. It is used by the Bridge
Detection state machine for the automatic identification
of edge ports. The default is false."
REFERENCE
"IEEE 802.1D-2004"
::= { hpicfBridgeRstpPortEntry 8 }
hpicfBridgeRstpPortBpduFiltering OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This value indicates whether or not BPDUs need
to be filtered on this port. If the value is true the
received BPDUs will be dropped and no BPDUs will be
transmitted on the port. If the value is false the BPDUs
are being processed as usual. The default is false."
REFERENCE
"IEEE P802.1w"
::= { hpicfBridgeRstpPortEntry 9 }
-- **********************************************************************
-- Loop Protection Objects
-- **********************************************************************
-- Port Remediation Textual Convention
LoopProtectReceiverAction::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
" This TC describes the actions a port that receives a loop
protection protocol packet can take.
The disableTx(1) enumeration indicates that the sender of
the loop protect packet will be disabled.
The noDisable(2) enumeration indicates that no port is to
be disabled."
SYNTAX INTEGER
{
disableTx(1),
noDisable(2)
}
hpicfBridgeLoopProtect OBJECT IDENTIFIER ::= { hpicfBridgeObjects 5 }
hpicfBridgeLoopProtectNotifications
OBJECT IDENTIFIER ::= { hpicfBridgeLoopProtect 0 }
hpicfBridgeLoopProtectBase
OBJECT IDENTIFIER ::= { hpicfBridgeLoopProtect 1 }
hpicfBridgeLoopProtectPort
OBJECT IDENTIFIER ::= { hpicfBridgeLoopProtect 2 }
hpicfBridgeLoopProtectInterval OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The interval in seconds at which loop protection packets are
transmitted. The default value is 5 seconds."
::= { hpicfBridgeLoopProtectBase 1 }
hpicfBridgeLoopProtectTrapLoopDetectEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether notifications should be sent when a loop
is detected on a port. By default this object will
have a value of false(2)."
::= { hpicfBridgeLoopProtectBase 2 }
hpicfBridgeLoopProtectEnableTimer OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The time in seconds to wait before reenabling a port
disabled by loop protection. When a port is disabled by
loop protection a reenable timer for the port is initialized
with the value of this period. If the period is not equal to
zero the port will be reenabled after the period has
elapsed. Otherwise the port will remain disabled."
::= { hpicfBridgeLoopProtectBase 3 }
hpicfBridgeLoopProtectPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfBridgeLoopProtectPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Per-interface configuration for Loop Protection."
::= { hpicfBridgeLoopProtectPort 1 }
hpicfBridgeLoopProtectPortEntry OBJECT-TYPE
SYNTAX HpicfBridgeLoopProtectPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Loop Protection configuration information for
a single port."
INDEX { ifIndex }
::= { hpicfBridgeLoopProtectPortTable 1 }
HpicfBridgeLoopProtectPortEntry ::=
SEQUENCE {
hpicfBridgeLoopProtectPortEnable TruthValue,
hpicfBridgeLoopProtectPortLoopDetected TruthValue,
hpicfBridgeLoopProtectPortLastLoopTime TimeStamp,
hpicfBridgeLoopProtectPortLoopCount Counter32,
hpicfBridgeLoopProtectPortReceiverAction LoopProtectReceiverAction
}
hpicfBridgeLoopProtectPortEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object indicates whether this port has
Loop protection enabled. The default value is FALSE"
::= { hpicfBridgeLoopProtectPortEntry 1 }
hpicfBridgeLoopProtectPortLoopDetected OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object will be set to TRUE when a loop is detected on
the port. The value of this object will be reset to FALSE when
the port's hpicfBridgeLoopProtectPortEnable is set to
FALSE."
::= { hpicfBridgeLoopProtectPortEntry 2 }
hpicfBridgeLoopProtectPortLastLoopTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of sysUpTime when a loop was last detected
on this port. A value of 0 means that the timestamp has
not been set."
::= { hpicfBridgeLoopProtectPortEntry 3 }
hpicfBridgeLoopProtectPortLoopCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "When the loop protect feature is enabled on the port this
object counts the number of loops detected on the port.
When the feature is disabled on the port the value of this
object is set to 0."
::= { hpicfBridgeLoopProtectPortEntry 4 }
hpicfBridgeLoopProtectPortReceiverAction OBJECT-TYPE
SYNTAX LoopProtectReceiverAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls the action taken when a Loop protection packet is
received on this port. When set to 'disableTx' the port
that transmitted the packet will be disabled. When set to
'noDisable' the transmitting port will not be disabled."
::= { hpicfBridgeLoopProtectPortEntry 5 }
-- **********************************************************************
-- hpicfBridgeLoopProtect Notifications
-- **********************************************************************
hpicfBridgeLoopProtectLoopDetectedNotification NOTIFICATION-TYPE
OBJECTS { ifIndex,
hpicfBridgeLoopProtectPortLoopCount,
hpicfBridgeLoopProtectPortReceiverAction}
STATUS current
DESCRIPTION "A hpicfBridgeLoopProtectLoopDetectedNotification signifies
that a loop has been detected by the loop protection protocol.
Generation of this notification is controlled by
hpicfBridgeLoopProtectTrapLoopDetectEnable. To prevent
excessive notifications this trap is rate-limited to allow
a maximum of 1 notifications every 30 seconds.
Notifications that are not sent due to rate-limiting are
dropped, and not queued up to be sent later."
::= { hpicfBridgeLoopProtectNotifications 1 }
-- **********************************************************************
-- Local Mirror Session Objects
-- **********************************************************************
hpicfBridgeMirrorSession OBJECT IDENTIFIER
::= { hpicfBridgeObjects 6 }
hpicfBridgeMirrorSessionBase OBJECT IDENTIFIER
::= { hpicfBridgeMirrorSession 1 }
hpicfBridgeMirrorSessionDestination OBJECT IDENTIFIER
::= { hpicfBridgeMirrorSession 2 }
hpicfBridgeMirrorSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpicfBridgeMirrorSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains mirror session information
related to a given specified destination. A mirror
session is a group of one or more portCopyEntries
all having the same specified destination. A given
specified destination may be associated with more
then one mirror session."
::= { hpicfBridgeMirrorSessionDestination 1 }
hpicfBridgeMirrorSessionEntry OBJECT-TYPE
SYNTAX HpicfBridgeMirrorSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the hpicfBridgeMirrorSessionEntry contains
mirror session specific identification
information."
AUGMENTS { portCopyEntry }
::= { hpicfBridgeMirrorSessionTable 1 }
HpicfBridgeMirrorSessionEntry ::=
SEQUENCE {
hpicfBridgeMirrorSessionID Integer32
}
hpicfBridgeMirrorSessionID OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This variable is valid only for mirroring
transfers. It allows mirroring destinations
to be grouped. A given hpicfBridgeMirrorSessionID
can only be used with 1 destination. However,
multiple sources may be related to the same
hpicfBridgeMirrorSessionID. To ensure that the
hpicfBridgeMirrorSessionID is properly assigned,
it can only be updated when the respective
portCopyEntry object is in the notReady state.
For non-mirroring transfers, the value should
be set to 0. "
DEFVAL { 1 }
::= { hpicfBridgeMirrorSessionEntry 1 }
-- **********************************************************************
-- Conformance information
-- **********************************************************************
hpicfBridgeConformance OBJECT IDENTIFIER ::= { hpicfBridge 2 }
hpicfBridgeGroups OBJECT IDENTIFIER ::= { hpicfBridgeConformance 1 }
hpicfBridgeCompliances OBJECT IDENTIFIER ::= { hpicfBridgeConformance 2 }
hpicfBridgeNotGroups OBJECT IDENTIFIER ::= { hpicfBridgeConformance 3 }
hpicfBridgeVlanBaseGroup OBJECT-GROUP
OBJECTS { hpicfBridgeMaxVlans,
hpicfBridgeVlanEnable,
hpicfBridgePrimaryVlan,
hpicfBridgeVlanConfigStatus }
STATUS current
DESCRIPTION "Basic VLAN configuration information that is not
in the standard 802.1Q Bridge MIB."
::= { hpicfBridgeGroups 1 }
hpicfBridgeGvrpPortGroup OBJECT-GROUP
OBJECTS { hpicfBridgeGvrpRestrictedVlanReg }
STATUS current
DESCRIPTION "GVRP configuration information that is not (yet)
in the standard 802.1Q Bridge MIB.
Note that this information is very likely to be added
to a future update of the 802.1Q Bridge MIB, at which
time, support for objects in this group will most
likely be deprecated."
::= { hpicfBridgeGroups 2 }
hpicfBridgeRstpBaseGroup OBJECT-GROUP
OBJECTS { hpicfBridgeRstpForceVersion,
hpicfBridgeRstpConfigStatus,
hpicfBridgeRstpProtocolVersion,
hpicfBridgeRstpAdminStatus,
hpicfBridgeRstpPortTable }
STATUS current
DESCRIPTION "Rapid Spanning Tree Protocol (RSTP) configuration
information that is in neither the standard 802.1w
MIB, nor the standard 802.1d (STP) MIB.
Note that as RSTP improves compatibility, some
objects in this MIB will likely be deprecated."
::= {hpicfBridgeGroups 3 }
hpicfBridgeLoopProtectBaseGroup OBJECT-GROUP
OBJECTS { hpicfBridgeLoopProtectInterval,
hpicfBridgeLoopProtectEnableTimer,
hpicfBridgeLoopProtectTrapLoopDetectEnable,
hpicfBridgeLoopProtectPortEnable,
hpicfBridgeLoopProtectPortLoopDetected,
hpicfBridgeLoopProtectPortLastLoopTime,
hpicfBridgeLoopProtectPortLoopCount,
hpicfBridgeLoopProtectPortReceiverAction
}
STATUS current
DESCRIPTION "A collection of objects providing basic instrumentation
and control of the HP Loop protection entity."
::= {hpicfBridgeGroups 4 }
-- **********************************************************************
-- Notification groups
-- **********************************************************************
hpicfBridgeLoopProtectNotGrp NOTIFICATION-GROUP
NOTIFICATIONS { hpicfBridgeLoopProtectLoopDetectedNotification }
STATUS current
DESCRIPTION "Notifications for Loop protection."
::= { hpicfBridgeNotGroups 1 }
hpicfBridgeMirrorSessionBaseGroup OBJECT-GROUP
OBJECTS { hpicfBridgeMirrorSessionID
}
STATUS current
DESCRIPTION "A collection of objects providing identification
of a mirroring session entity."
::= {hpicfBridgeGroups 5 }
-- **********************************************************************
-- Compliance statements
-- **********************************************************************
hpicfBridgeCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for HP Switches with IEEE
802.1Q VLAN support for bridging objects not found
in the standard Bridge MIBs."
MODULE
MANDATORY-GROUPS { hpicfBridgeVlanBaseGroup }
GROUP hpicfBridgeGvrpPortGroup
DESCRIPTION "Support for this group is required for switches
that support GVRP until such time as support for
these objects is added to a standard MIB."
::= { hpicfBridgeCompliances 1 }
hpicfBridgeComplianceRevTwo MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for HP Switches with IEEE
802.1W Rapid Spanning Tree Protocol support for
bridging objects not found in the standard Bridge
MIBs."
MODULE
MANDATORY-GROUPS { hpicfBridgeVlanBaseGroup }
GROUP hpicfBridgeGvrpPortGroup
DESCRIPTION "Support for this group is required for switches
that support GVRP until such time as support for
these objects is added to a standard MIB."
GROUP hpicfBridgeRstpBaseGroup
DESCRIPTION "Support for this group is required for switches
that implement RSTP until such time as support for
these objects is added to a standard MIB."
::= { hpicfBridgeCompliances 2 }
hpicfBridgeComplianceRevThree MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for HP Switches with IEEE
802.1W Rapid Spanning Tree Protocol support for
bridging objects not found in the standard Bridge
MIBs."
MODULE
MANDATORY-GROUPS { hpicfBridgeVlanBaseGroup }
GROUP hpicfBridgeGvrpPortGroup
DESCRIPTION "Support for this group is required for switches
that support GVRP until such time as support for
these objects is added to a standard MIB."
GROUP hpicfBridgeRstpBaseGroup
DESCRIPTION "Support for this group is required for switches
that implement RSTP until such time as support for
these objects is added to a standard MIB."
::= { hpicfBridgeCompliances 3 }
hpicfBridgeComplianceRevFour MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for HP Switches with IEEE
802.1W Rapid Spanning Tree Protocol support for
bridging objects not found in the standard Bridge
MIBs."
MODULE
MANDATORY-GROUPS { hpicfBridgeVlanBaseGroup }
GROUP hpicfBridgeGvrpPortGroup
DESCRIPTION "Support for this group is required for switches
that support GVRP until such time as support for
these objects is added to a standard MIB."
GROUP hpicfBridgeRstpBaseGroup
DESCRIPTION "Support for this group is required for switches
that implement RSTP until such time as support for
these objects is added to a standard MIB."
GROUP hpicfBridgeMirrorSessionBaseGroup
DESCRIPTION "Support for this group is mandatory for switches
that implement the multi session mirroring
(intelligent mirroring) feature."
::= { hpicfBridgeCompliances 4 }
hpicfBridgeLoopProtectCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for HP Switches with
support for hpicfBridge loop protection objects."
MODULE
MANDATORY-GROUPS { hpicfBridgeLoopProtectBaseGroup,
hpicfBridgeLoopProtectNotifications }
GROUP hpicfBridgeLoopProtectBaseGroup
DESCRIPTION "Support for this group is mandatory for switches
that implement the loop protection feature."
GROUP hpicfBridgeLoopProtectNotifications
DESCRIPTION "Implementation of this group is mandatory
for switches that implement the loop protection
feature."
::= { hpicfBridgeCompliances 5 }
END