1486 lines
56 KiB
Plaintext
1486 lines
56 KiB
Plaintext
|
HP-ICF-TRANSCEIVER-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
OBJECT-TYPE, MODULE-IDENTITY, Integer32, Unsigned32, TimeTicks
|
||
|
FROM SNMPv2-SMI
|
||
|
SnmpAdminString
|
||
|
FROM SNMP-FRAMEWORK-MIB
|
||
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
||
|
FROM SNMPv2-CONF
|
||
|
TruthValue
|
||
|
FROM SNMPv2-TC
|
||
|
hpSwitch
|
||
|
FROM HP-ICF-OID
|
||
|
ifIndex
|
||
|
FROM IF-MIB;
|
||
|
|
||
|
hpicfTransceiverMIB MODULE-IDENTITY
|
||
|
LAST-UPDATED "201107250000Z" -- July 25, 2011
|
||
|
ORGANIZATION "HP Networking"
|
||
|
CONTACT-INFO "Hewlett Packard Company
|
||
|
8000 Foothills Blvd.
|
||
|
Roseville, CA 95747"
|
||
|
DESCRIPTION "This MIB module describes HP transceiver
|
||
|
information."
|
||
|
REVISION "201107250000Z" -- July 25, 2011
|
||
|
DESCRIPTION "Deprecated hpicfXcvrDiagnosticsTimeStamp, add
|
||
|
hpicfXcvrDiagnosticsTimeTicks."
|
||
|
REVISION "201106080000Z" -- June 8, 2011
|
||
|
DESCRIPTION "Add objects for reporting phy and cable
|
||
|
diagnostics information."
|
||
|
REVISION "201103140000Z" -- March 14, 2011
|
||
|
DESCRIPTION "Change hpicfXcvrInfoEntry INDEX to ifIndex and
|
||
|
hpicfXcvrPortIndex to Integer32 and read-only."
|
||
|
REVISION "201103020000Z" -- March 2, 2011
|
||
|
DESCRIPTION "Management Infromation Base module for transceiver
|
||
|
information and statistics."
|
||
|
|
||
|
::= { hpSwitch 82 }
|
||
|
|
||
|
-- *******************************************************************
|
||
|
-- Textual Conventions
|
||
|
-- *******************************************************************
|
||
|
|
||
|
-- *******************************************************************
|
||
|
-- Transceiver Objects
|
||
|
-- *******************************************************************
|
||
|
|
||
|
hpicfXcvrObjects OBJECT IDENTIFIER
|
||
|
::= { hpicfTransceiverMIB 1 }
|
||
|
|
||
|
hpicfXcvrInfo OBJECT IDENTIFIER
|
||
|
::= { hpicfXcvrObjects 1 }
|
||
|
|
||
|
-- *******************************************************************
|
||
|
-- Transceiver Info
|
||
|
-- *******************************************************************
|
||
|
|
||
|
hpicfXcvrInfoTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF HpicfXcvrInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of objects that display transceiver
|
||
|
characteristics."
|
||
|
::= { hpicfXcvrInfo 1 }
|
||
|
|
||
|
hpicfXcvrInfoEntry OBJECT-TYPE
|
||
|
SYNTAX HpicfXcvrInfoEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A set of objects that displays information of
|
||
|
a transceiver."
|
||
|
INDEX { ifIndex }
|
||
|
::= { hpicfXcvrInfoTable 1 }
|
||
|
|
||
|
HpicfXcvrInfoEntry ::=
|
||
|
SEQUENCE {
|
||
|
hpicfXcvrPortIndex Integer32,
|
||
|
hpicfXcvrPortDesc SnmpAdminString,
|
||
|
hpicfXcvrModel SnmpAdminString,
|
||
|
hpicfXcvrSerial SnmpAdminString,
|
||
|
hpicfXcvrType SnmpAdminString,
|
||
|
hpicfXcvrConnectorType SnmpAdminString,
|
||
|
hpicfXcvrWavelength SnmpAdminString,
|
||
|
hpicfXcvrTxDist SnmpAdminString,
|
||
|
hpicfXcvrDiagnostics INTEGER,
|
||
|
hpicfXcvrDiagnosticsUpdate TruthValue,
|
||
|
hpicfXcvrTemp Integer32,
|
||
|
hpicfXcvrVoltage Unsigned32,
|
||
|
hpicfXcvrBias Unsigned32,
|
||
|
hpicfXcvrTxPower Integer32,
|
||
|
hpicfXcvrRxPower Integer32,
|
||
|
hpicfXcvrAlarms BITS,
|
||
|
hpicfXcvrErrors BITS,
|
||
|
hpicfXcvrTempHiAlarm Integer32,
|
||
|
hpicfXcvrTempLoAlarm Integer32,
|
||
|
hpicfXcvrTempHiWarn Integer32,
|
||
|
hpicfXcvrTempLoWarn Integer32,
|
||
|
hpicfXcvrVccHiAlarm Unsigned32,
|
||
|
hpicfXcvrVccLoAlarm Unsigned32,
|
||
|
hpicfXcvrVccHiWarn Unsigned32,
|
||
|
hpicfXcvrVccLoWarn Unsigned32,
|
||
|
hpicfXcvrBiasHiAlarm Unsigned32,
|
||
|
hpicfXcvrBiasLoAlarm Unsigned32,
|
||
|
hpicfXcvrBiasHiWarn Unsigned32,
|
||
|
hpicfXcvrBiasLoWarn Unsigned32,
|
||
|
hpicfXcvrPwrOutHiAlarm Unsigned32,
|
||
|
hpicfXcvrPwrOutLoAlarm Unsigned32,
|
||
|
hpicfXcvrPwrOutHiWarn Unsigned32,
|
||
|
hpicfXcvrPwrOutLoWarn Unsigned32,
|
||
|
hpicfXcvrRcvPwrHiAlarm Unsigned32,
|
||
|
hpicfXcvrRcvPwrLoAlarm Unsigned32,
|
||
|
hpicfXcvrRcvPwrHiWarn Unsigned32,
|
||
|
hpicfXcvrRcvPwrLoWarn Unsigned32,
|
||
|
hpicfXcvrDiagnosticsTimeStamp SnmpAdminString,
|
||
|
hpicfXcvrPhyLinkStatus INTEGER,
|
||
|
hpicfXcvrPhySpeed Unsigned32,
|
||
|
hpicfXcvrPhyDuplex INTEGER,
|
||
|
hpicfXcvrMdiPairACableStatus INTEGER,
|
||
|
hpicfXcvrMdiPairACableLength Unsigned32,
|
||
|
hpicfXcvrMdiPairADistanceToFault Unsigned32,
|
||
|
hpicfXcvrMdiPairAPolaritySwap INTEGER,
|
||
|
hpicfXcvrMdiPairASkew Unsigned32,
|
||
|
hpicfXcvrMdiPairBCableStatus INTEGER,
|
||
|
hpicfXcvrMdiPairBCableLength Unsigned32,
|
||
|
hpicfXcvrMdiPairBDistanceToFault Unsigned32,
|
||
|
hpicfXcvrMdiPairBPolaritySwap INTEGER,
|
||
|
hpicfXcvrMdiPairBSkew Unsigned32,
|
||
|
hpicfXcvrMdiPairCCableStatus INTEGER,
|
||
|
hpicfXcvrMdiPairCCableLength Unsigned32,
|
||
|
hpicfXcvrMdiPairCDistanceToFault Unsigned32,
|
||
|
hpicfXcvrMdiPairCPolaritySwap INTEGER,
|
||
|
hpicfXcvrMdiPairCSkew Unsigned32,
|
||
|
hpicfXcvrMdiPairDCableStatus INTEGER,
|
||
|
hpicfXcvrMdiPairDCableLength Unsigned32,
|
||
|
hpicfXcvrMdiPairDDistanceToFault Unsigned32,
|
||
|
hpicfXcvrMdiPairDPolaritySwap INTEGER,
|
||
|
hpicfXcvrMdiPairDSkew Unsigned32,
|
||
|
hpicfXcvrMdiPairABSwap INTEGER,
|
||
|
hpicfXcvrMdiPairCDSwap INTEGER,
|
||
|
hpicfXcvrDiagnosticsTimeTicks TimeTicks
|
||
|
}
|
||
|
|
||
|
hpicfXcvrPortIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32(1..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The interface number for this entry."
|
||
|
::= { hpicfXcvrInfoEntry 1 }
|
||
|
|
||
|
hpicfXcvrPortDesc OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..8))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A textual description of the interface."
|
||
|
::= { hpicfXcvrInfoEntry 2 }
|
||
|
|
||
|
hpicfXcvrModel OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..32))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A textual description of the transceiver
|
||
|
model number."
|
||
|
::= { hpicfXcvrInfoEntry 3 }
|
||
|
|
||
|
hpicfXcvrSerial OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..32))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A textual description of the transceiver
|
||
|
serial number."
|
||
|
::= { hpicfXcvrInfoEntry 4 }
|
||
|
|
||
|
hpicfXcvrType OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..32))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A textual description of the transceiver type."
|
||
|
::= { hpicfXcvrInfoEntry 5 }
|
||
|
|
||
|
hpicfXcvrConnectorType OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..64))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A textual description of the transceiver
|
||
|
connector type."
|
||
|
::= { hpicfXcvrInfoEntry 6 }
|
||
|
|
||
|
hpicfXcvrWavelength OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..96))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A textual description of the central optical
|
||
|
wavelength.
|
||
|
|
||
|
n/a will be reported for copper transceivers."
|
||
|
::= { hpicfXcvrInfoEntry 7 }
|
||
|
|
||
|
hpicfXcvrTxDist OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..64))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A textual description of the link length
|
||
|
supported by the transceiver."
|
||
|
::= { hpicfXcvrInfoEntry 8 }
|
||
|
|
||
|
hpicfXcvrDiagnostics OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
none(0),
|
||
|
dom(1),
|
||
|
vct(2),
|
||
|
other(3)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates transceiver diagnostic support.
|
||
|
May be one of Virtual Cable Test (VCT), Diagnostic
|
||
|
Optical Monitoring (DOM), other or none."
|
||
|
::= { hpicfXcvrInfoEntry 9 }
|
||
|
|
||
|
hpicfXcvrDiagnosticsUpdate OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object will cause specific actions
|
||
|
depending on the diagnostic support of the
|
||
|
transceiver.
|
||
|
|
||
|
Transceiver Diagnostic support:
|
||
|
|
||
|
None : No action taken.
|
||
|
DOM : Will update diagnostic information
|
||
|
for the transceiver.
|
||
|
VCT : Will update diagnostic information
|
||
|
for the transceiver.
|
||
|
Other : Vendor specific.
|
||
|
|
||
|
The value of the object will be reset after
|
||
|
the completion of the update.
|
||
|
|
||
|
Please note: VCT and other (cable-diagnostics)
|
||
|
may cause a loss of link and take a few second
|
||
|
to run for each interface."
|
||
|
::= { hpicfXcvrInfoEntry 10 }
|
||
|
|
||
|
hpicfXcvrTemp OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "thousandths of degrees Celsius"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is transceiver internal temperature
|
||
|
in thousandths of degrees Celsius.
|
||
|
|
||
|
As an example: 49120 is 49.120 degrees Celsius.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 11 }
|
||
|
|
||
|
hpicfXcvrVoltage OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "hundreds of microvolts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is transceiver supply voltage
|
||
|
in hundreds of microvolts.
|
||
|
|
||
|
As an example: 32928 is 3.2928 volts.
|
||
|
|
||
|
Will be zero if the transceiver does not report
|
||
|
this object.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 12 }
|
||
|
|
||
|
hpicfXcvrBias OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "microamps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is Tx bias current in microamps.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 13 }
|
||
|
|
||
|
hpicfXcvrTxPower OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "thousandths of dBm"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is transmit output power
|
||
|
in thousandths of dBm.
|
||
|
|
||
|
As an example: -5840 is -5.840dBm.
|
||
|
|
||
|
-in dBm (0 microwatts) will be reported as -99999999.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 14 }
|
||
|
|
||
|
hpicfXcvrRxPower OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "thousandths of dBm"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is received optical power
|
||
|
in thousandths of dBm.
|
||
|
|
||
|
As an example: -5840 is -5.840dBm.
|
||
|
|
||
|
-in dBm (0 microwatts) will be reported as -99999999.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 15 }
|
||
|
|
||
|
hpicfXcvrAlarms OBJECT-TYPE
|
||
|
SYNTAX BITS {
|
||
|
rxPowerLowWarning(0),
|
||
|
rxPowerHighWarning(1),
|
||
|
txPowerLowWarning(2),
|
||
|
txPowerHighWarning(3),
|
||
|
txBiasLowWarning(4),
|
||
|
txBiasHighWarning(5),
|
||
|
vccLowWarning(6),
|
||
|
vccHighWarning(7),
|
||
|
tempLowWarning(8),
|
||
|
tempHighWarning(9),
|
||
|
rxPowerLowAlarm(10),
|
||
|
rxPowerHighAlarm(11),
|
||
|
txPowerLowAlarm(12),
|
||
|
txPowerHighAlarm(13),
|
||
|
txBiasLowAlarm(14),
|
||
|
txBiasHighAlarm(15),
|
||
|
vccLowAlarm(16),
|
||
|
vccHighAlarm(17),
|
||
|
tempLowAlarm(18),
|
||
|
tempHighAlarm(19)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Bitmask indicating transceiver alarms,
|
||
|
Rx power low warning(0)
|
||
|
Rx power high warning(1)
|
||
|
Tx power low warning(2)
|
||
|
Tx power high warning(3)
|
||
|
Tx bias low warning(4)
|
||
|
Tx bias high warning(5)
|
||
|
Vcc low warning(6)
|
||
|
Vcc high warning(7)
|
||
|
Temp low warning(8)
|
||
|
Temp high warning(9)
|
||
|
Rx power low alarm(10)
|
||
|
Rx power high alarm(11)
|
||
|
Tx power low alarm(12)
|
||
|
Tx power high alarm(13)
|
||
|
Tx bias low alarm(14)
|
||
|
Tx bias high alarm(15)
|
||
|
Vcc low alarm(16)
|
||
|
Vcc high alarm(17)
|
||
|
Temp low alarm(18)
|
||
|
Temp high alarm(19)
|
||
|
|
||
|
Unused(20-31)
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 16 }
|
||
|
|
||
|
hpicfXcvrErrors OBJECT-TYPE
|
||
|
SYNTAX BITS {
|
||
|
xcvrIOError(0),
|
||
|
xcvrChecksum(1),
|
||
|
xcvrTypeAndPortConfigMismatch(2),
|
||
|
xcvrTypeNotSupported(3),
|
||
|
wisLocalFault(4),
|
||
|
rcvOpticalPowerFault(5),
|
||
|
pmapmdReceiverLocalFault(6),
|
||
|
pcsReceiveLocalFault(7),
|
||
|
phyXSReceiveLocalFault(8),
|
||
|
laserBiasCurrentFault(9),
|
||
|
laserTemperatureFault(10),
|
||
|
laserOutputPowerFault(11),
|
||
|
txFault(12),
|
||
|
pmapmdTransmitterLocalFault(13),
|
||
|
pcsTransmitLocalFault(14),
|
||
|
phyXSTransmitLocalFault(15),
|
||
|
rxLossOfSignal(16)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Bitmask indicating transceiver errors.
|
||
|
Transceiver information I/O error(0)
|
||
|
Transceiver information checksum error(1)
|
||
|
Transceiver type and port configuration mismatch(2)
|
||
|
Transceiver type not supported by port hardware(3)
|
||
|
WIS local fault(4)
|
||
|
Receive optical power fault(5)
|
||
|
PMA/PMD receiver local fault(6)
|
||
|
PCS receive local fault(7)
|
||
|
PHY XS receive local fault(8)
|
||
|
Laser bias current fault(9)
|
||
|
Laser temperature fault(10)
|
||
|
Laser output power fault(11)
|
||
|
TX fault(12)
|
||
|
PMA/PMD transmitter local fault(13)
|
||
|
PCS transmit local fault(14)
|
||
|
PHY XS Transmit Local Fault(15)
|
||
|
RX loss of signal(16)
|
||
|
|
||
|
Unused(17-31)
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 17 }
|
||
|
|
||
|
hpicfXcvrTempHiAlarm OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "thousandths of degrees Celsius"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver temperature high alarm
|
||
|
threshold limit in thousandths of degrees Celsius.
|
||
|
|
||
|
As an example: 49120 is 49.120 degrees Celsius.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 18 }
|
||
|
|
||
|
hpicfXcvrTempLoAlarm OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "thousandths of degrees Celsius"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver temperature low alarm
|
||
|
threshold limit in thousandths of degrees Celsius.
|
||
|
|
||
|
As an example: 49120 is 49.120 degrees Celsius.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 19 }
|
||
|
|
||
|
hpicfXcvrTempHiWarn OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "thousandths of degrees Celsius"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver temperature high warning
|
||
|
threshold limit in thousandths of degrees Celsius.
|
||
|
|
||
|
As an example: 49120 is 49.120 degrees Celsius.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 20 }
|
||
|
|
||
|
hpicfXcvrTempLoWarn OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
UNITS "thousandths of degrees Celsius"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver temperature low warning
|
||
|
threshold limit in thousandths of degrees Celsius.
|
||
|
|
||
|
As an example: 49120 is 49.120 degrees Celsius.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 21 }
|
||
|
|
||
|
hpicfXcvrVccHiAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "hundreds of microvolts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver VCC high alarm
|
||
|
threshold limit in hundreds of microvolts.
|
||
|
|
||
|
As an example: 32928 is 3.2928 volts.
|
||
|
|
||
|
Returns zero if not supported on the transceiver.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 22 }
|
||
|
|
||
|
hpicfXcvrVccLoAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "hundreds of microvolts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver VCC low alarm
|
||
|
threshold limit in hundreds of microvolts.
|
||
|
|
||
|
As an example: 32928 is 3.2928 volts.
|
||
|
|
||
|
Returns zero if not supported on the transceiver.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 23 }
|
||
|
|
||
|
hpicfXcvrVccHiWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "hundreds of microvolts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver VCC high warning
|
||
|
threshold limit in hundreds of microvolts.
|
||
|
|
||
|
As an example: 32928 is 3.2928 volts.
|
||
|
|
||
|
Returns zero if not supported on the transceiver.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 24 }
|
||
|
|
||
|
hpicfXcvrVccLoWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "hundreds of microvolts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver VCC low warning
|
||
|
threshold limit in hundreds of microvolts.
|
||
|
|
||
|
As an example: 32928 is 3.2928 volts.
|
||
|
|
||
|
Returns zero if not supported on the transceiver.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 25 }
|
||
|
|
||
|
hpicfXcvrBiasHiAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "microamps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver bias high alarm
|
||
|
threshold limit in microamps.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 26 }
|
||
|
|
||
|
hpicfXcvrBiasLoAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "microamps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver bias low alarm
|
||
|
threshold limit in microamps.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 27 }
|
||
|
|
||
|
hpicfXcvrBiasHiWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "microamps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver bias high warning
|
||
|
threshold limit in microamps.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 28 }
|
||
|
|
||
|
hpicfXcvrBiasLoWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "microamps"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver bias low warning
|
||
|
threshold limit in microamps.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 29 }
|
||
|
|
||
|
hpicfXcvrPwrOutHiAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver transmit power high alarm
|
||
|
threshold limit in tenths of microwatts.
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 30 }
|
||
|
|
||
|
hpicfXcvrPwrOutLoAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver transmit power low alarm
|
||
|
threshold limit in tenths of microwatts.
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 31 }
|
||
|
|
||
|
hpicfXcvrPwrOutHiWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver transmit power high warning
|
||
|
threshold limit in tenths of microwatts
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 32 }
|
||
|
|
||
|
hpicfXcvrPwrOutLoWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver transmit power low warning
|
||
|
threshold limit in tenths of microwatts.
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 33 }
|
||
|
|
||
|
hpicfXcvrRcvPwrHiAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver receive power high alarm
|
||
|
threshold limit in tenths of microwatts.
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 34 }
|
||
|
|
||
|
hpicfXcvrRcvPwrLoAlarm OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver receive power low alarm
|
||
|
threshold limit in tenths of microwatts.
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 35 }
|
||
|
|
||
|
hpicfXcvrRcvPwrHiWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver receive power high warning
|
||
|
threshold limit in tenths of microwatts.
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 36 }
|
||
|
|
||
|
hpicfXcvrRcvPwrLoWarn OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65535)
|
||
|
UNITS "tenths of microwatts"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Transceiver receive power low warning
|
||
|
threshold limit in tenths of microwatts.
|
||
|
|
||
|
As an example: 10000 is 1 milliwatt.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is DOM."
|
||
|
::= { hpicfXcvrInfoEntry 37 }
|
||
|
|
||
|
hpicfXcvrDiagnosticsTimeStamp OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(1..64))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"********* THIS OBJECT IS DEPRECATED *********
|
||
|
|
||
|
A textual description of the diagnostics
|
||
|
information updated for the last time in the
|
||
|
transceiver.
|
||
|
|
||
|
This object has been deprecated. Its functionality
|
||
|
has been replaced by hpicfXcvrDiagnosticsTimeticks."
|
||
|
::= { hpicfXcvrInfoEntry 38 }
|
||
|
|
||
|
hpicfXcvrPhyLinkStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
down(0),
|
||
|
up(1)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the link status as reported
|
||
|
by the physical entity.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 39 }
|
||
|
|
||
|
hpicfXcvrPhySpeed OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "megabits per second"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the speed in Mbps as reported
|
||
|
by the physical entity.
|
||
|
|
||
|
Will be zero if speed and duplex are unresolved.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 40 }
|
||
|
|
||
|
hpicfXcvrPhyDuplex OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
half(0),
|
||
|
full(1),
|
||
|
unspecified(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the duplex as reported by
|
||
|
the physical entity.
|
||
|
|
||
|
Will be unspecified if speed and duplex are unresolved.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 41 }
|
||
|
|
||
|
hpicfXcvrMdiPairACableStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
short(1),
|
||
|
open(2),
|
||
|
failed(3),
|
||
|
impedanceMismatch(4),
|
||
|
unspecified(5)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the diagnostics
|
||
|
test status on the cable pair.
|
||
|
|
||
|
Normal = No cable fault detected.
|
||
|
Open = Lack of continuity between ends.
|
||
|
Short = Short detected.
|
||
|
Impedance mismatch =
|
||
|
- Cable pair is not connected properly or
|
||
|
- Cable pair is damaged or
|
||
|
- Connector is faulty.
|
||
|
Failed = TDR test failed on cable pair.
|
||
|
Unspecified : This object is unavailable or not reported.
|
||
|
|
||
|
As reported through cable diagnostics.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 42 }
|
||
|
|
||
|
hpicfXcvrMdiPairACableLength OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the cable pair length in
|
||
|
meters as reported by cable diagnostics.
|
||
|
|
||
|
A gigabit link must be present for this object
|
||
|
to be non zero.
|
||
|
|
||
|
Will be zero if not available or the transceiver
|
||
|
does not report this object.
|
||
|
|
||
|
Accuracy is +/- 10 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 43 }
|
||
|
|
||
|
hpicfXcvrMdiPairADistanceToFault OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the distance in meters to
|
||
|
a fault in the cable pair as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be zero if no fault or the transceiver does not
|
||
|
report this object.
|
||
|
|
||
|
Accuracy is +/- 2 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 44 }
|
||
|
|
||
|
hpicfXcvrMdiPairAPolaritySwap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
reversed(1),
|
||
|
unspecified(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates if the cable pair connected
|
||
|
to the phy is inverted as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be unspecified if the this object is unavailable
|
||
|
or not reported.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 45 }
|
||
|
|
||
|
hpicfXcvrMdiPairASkew OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "nanoseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the delay skew in nanoseconds
|
||
|
of this cable pair and the fastest cable pair as
|
||
|
reported through cable diagnostics.
|
||
|
|
||
|
Will be zero if the lowest of the pairs or if the
|
||
|
transceiver does not report this object.
|
||
|
|
||
|
Accuracy is +/- 8 ns.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 46 }
|
||
|
|
||
|
hpicfXcvrMdiPairBCableStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
short(1),
|
||
|
open(2),
|
||
|
failed(3),
|
||
|
impedanceMismatch(4),
|
||
|
unspecified(5)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the cable diagnostics
|
||
|
test status on the cable pair.
|
||
|
|
||
|
Normal = No cable fault detected.
|
||
|
Open = Lack of continuity between ends.
|
||
|
Short = Short detected.
|
||
|
Impedance mismatch =
|
||
|
- Cable pair is not connected properly or
|
||
|
- Cable pair is damaged or
|
||
|
- Connector is faulty.
|
||
|
Failed = TDR test failed on cable pair.
|
||
|
Unspecified : This object is unavailable or not
|
||
|
reported.
|
||
|
|
||
|
As reported through cable diagnostics.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 47 }
|
||
|
|
||
|
hpicfXcvrMdiPairBCableLength OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the cable pair length in
|
||
|
meters as reported by cable diagnostics.
|
||
|
|
||
|
A gigabit link must be present for this object
|
||
|
to be non zero.
|
||
|
|
||
|
Will be zero if not available or the transceiver
|
||
|
does not report this object.
|
||
|
|
||
|
Accuracy is +/- 10 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 48 }
|
||
|
|
||
|
hpicfXcvrMdiPairBDistanceToFault OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the distance in meters to
|
||
|
a fault in the cable pair as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be zero if no fault or the transceiver does not
|
||
|
report this object.
|
||
|
|
||
|
Accuracy is +/- 2 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 49 }
|
||
|
|
||
|
hpicfXcvrMdiPairBPolaritySwap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
reversed(1),
|
||
|
unspecified(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates if the cable pair connected
|
||
|
to the phy were inverted as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be unspecified if the this object is unavailable
|
||
|
or not reported.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 50 }
|
||
|
|
||
|
hpicfXcvrMdiPairBSkew OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "nanoseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the delay skew in nanoseconds
|
||
|
of this cable pair and the fastest cable pair as
|
||
|
reported through cable diagnostics.
|
||
|
|
||
|
Will be zero if the lowest of the pairs or if the
|
||
|
transceiver does not report this object.
|
||
|
|
||
|
Accuracy is +/- 8 ns.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 51 }
|
||
|
|
||
|
hpicfXcvrMdiPairCCableStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
short(1),
|
||
|
open(2),
|
||
|
failed(3),
|
||
|
impedanceMismatch(4),
|
||
|
unspecified(5)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the cable diagnostics
|
||
|
test status on the cable pair.
|
||
|
|
||
|
Normal = No cable fault detected.
|
||
|
Open = Lack of continuity between ends.
|
||
|
Short = Short detected.
|
||
|
Impedance Mismatch =
|
||
|
- Cable pair is not connected properly or
|
||
|
- Cable pair is damaged or
|
||
|
- Connector is faulty.
|
||
|
Failed = TDR test failed on cable pair.
|
||
|
Unspecified : This object is unavailable or not reported.
|
||
|
|
||
|
As reported through cable diagnostics.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 52 }
|
||
|
|
||
|
hpicfXcvrMdiPairCCableLength OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the cable length in meters
|
||
|
of the cable pair as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
A gigabit link must be present for this object
|
||
|
to be non zero.
|
||
|
|
||
|
Will be zero if not available or the transceiver
|
||
|
does not report this object.
|
||
|
|
||
|
Accuracy is +/- 10 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 53 }
|
||
|
|
||
|
hpicfXcvrMdiPairCDistanceToFault OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the distance in meters to
|
||
|
a fault in the cable pair as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be zero if there is no fault or the
|
||
|
transceiver does not report this object.
|
||
|
|
||
|
Accuracy is +/- 2 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 54 }
|
||
|
|
||
|
hpicfXcvrMdiPairCPolaritySwap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
reversed(1),
|
||
|
unspecified(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates if the cable pair connected
|
||
|
to the phy were inverted as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be unspecified if the this object is unavailable
|
||
|
or not reported.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 55 }
|
||
|
|
||
|
hpicfXcvrMdiPairCSkew OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "nanoseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the delay skew in nanoseconds
|
||
|
of this cable pair and the fastest cable pair as
|
||
|
reported through cable diagnostics.
|
||
|
|
||
|
Will be zero if the lowest of the pairs or if the
|
||
|
transceiver does not report this object.
|
||
|
|
||
|
Accuracy is +/- 8 ns.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 56 }
|
||
|
|
||
|
hpicfXcvrMdiPairDCableStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
short(1),
|
||
|
open(2),
|
||
|
failed(3),
|
||
|
impedanceMismatch(4),
|
||
|
unspecified(5)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the cable diagnostics
|
||
|
test status on the cable pair.
|
||
|
|
||
|
Normal = No cable fault detected.
|
||
|
Open = Lack of continuity between ends.
|
||
|
Short = Short detected.
|
||
|
Impedance Mismatch =
|
||
|
- Cable pair is not connected properly or
|
||
|
- Cable pair is damaged or
|
||
|
- Connector is faulty.
|
||
|
Failed = TDR test failed on cable pair.
|
||
|
Unspecified : This object is unavailable or not
|
||
|
reported.
|
||
|
|
||
|
As reported through cable diagnostics.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 57 }
|
||
|
|
||
|
hpicfXcvrMdiPairDCableLength OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the cable length in meters
|
||
|
of the cable pair as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
A gigabit link must be present for this object
|
||
|
to be non zero.
|
||
|
|
||
|
Will be zero if not available or the transceiver
|
||
|
does not report this object.
|
||
|
|
||
|
Accuracy is +/- 10 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 58 }
|
||
|
|
||
|
hpicfXcvrMdiPairDDistanceToFault OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "meters"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the distance in meters to
|
||
|
a fault in the cable pair as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be zero if no fault or the transceiver does not
|
||
|
report this object.
|
||
|
|
||
|
Accuracy is +/- 2 meters.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 59 }
|
||
|
|
||
|
hpicfXcvrMdiPairDPolaritySwap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(0),
|
||
|
reversed(1),
|
||
|
unspecified(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates if the cable pair connected
|
||
|
to the phy were inverted as reported through cable
|
||
|
diagnostics.
|
||
|
|
||
|
Will be unspecified if the this object is unavailable
|
||
|
or not reported.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 60 }
|
||
|
|
||
|
hpicfXcvrMdiPairDSkew OBJECT-TYPE
|
||
|
SYNTAX Unsigned32(0..4294967295)
|
||
|
UNITS "nanoseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the delay skew in nanoseconds
|
||
|
of this cable pair and the fastest cable pair as
|
||
|
reported through cable diagnostics.
|
||
|
|
||
|
Will be zero if the lowest of the pairs or if the
|
||
|
transceiver does not report this object.
|
||
|
|
||
|
Accuracy is +/- 8 ns.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 61 }
|
||
|
|
||
|
hpicfXcvrMdiPairABSwap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
mdi(0),
|
||
|
mdix(1),
|
||
|
unspecified(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the if the channels are
|
||
|
swapped for channels A and B as reported through
|
||
|
cable diagnostics.
|
||
|
|
||
|
MDI : Channel A received on MDI[1], Channel B on MDI[0]
|
||
|
MDIX : Channel A received on MDI[0], Channel B on MDI[1]
|
||
|
Unspecified : This object is unavailable or not reported.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 62 }
|
||
|
|
||
|
hpicfXcvrMdiPairCDSwap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
mdi(0),
|
||
|
mdix(1),
|
||
|
unspecified(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates if the channels are
|
||
|
swapped for channels C and D as reported through
|
||
|
cable diagnostics.
|
||
|
|
||
|
MDI : Channel C received on MDI[3], Channel D on MDI[2]
|
||
|
MDIX : Channel C received on MDI[2], Channel D on MDI[3].
|
||
|
Unspecified : This object is unavailable or not reported.
|
||
|
|
||
|
The value of this object is valid when the value of
|
||
|
the hpicfXcvrDiagnostics object is VCT or other."
|
||
|
::= { hpicfXcvrInfoEntry 63 }
|
||
|
|
||
|
hpicfXcvrDiagnosticsTimeTicks OBJECT-TYPE
|
||
|
SYNTAX TimeTicks
|
||
|
UNITS "centi-seconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime of when this diagnostic
|
||
|
information was last updated. If this diagnostic
|
||
|
information was never updated, then this object
|
||
|
will contain a zero value."
|
||
|
::= { hpicfXcvrInfoEntry 64 }
|
||
|
|
||
|
-- *******************************************************************
|
||
|
-- Conformance Section
|
||
|
-- *******************************************************************
|
||
|
|
||
|
hpicfXcvrConformance OBJECT IDENTIFIER
|
||
|
::= { hpicfTransceiverMIB 2 }
|
||
|
|
||
|
hpicfXcvrGroups OBJECT IDENTIFIER
|
||
|
::= { hpicfXcvrConformance 1 }
|
||
|
|
||
|
hpicfXcvrInfoGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
hpicfXcvrPortIndex,
|
||
|
hpicfXcvrPortDesc,
|
||
|
hpicfXcvrModel,
|
||
|
hpicfXcvrSerial,
|
||
|
hpicfXcvrType,
|
||
|
hpicfXcvrConnectorType,
|
||
|
hpicfXcvrWavelength,
|
||
|
hpicfXcvrTxDist,
|
||
|
hpicfXcvrDiagnostics,
|
||
|
hpicfXcvrDiagnosticsUpdate,
|
||
|
hpicfXcvrTemp,
|
||
|
hpicfXcvrVoltage,
|
||
|
hpicfXcvrBias,
|
||
|
hpicfXcvrRxPower,
|
||
|
hpicfXcvrTxPower,
|
||
|
hpicfXcvrAlarms,
|
||
|
hpicfXcvrErrors,
|
||
|
hpicfXcvrTempHiAlarm,
|
||
|
hpicfXcvrTempLoAlarm,
|
||
|
hpicfXcvrTempHiWarn,
|
||
|
hpicfXcvrTempLoWarn,
|
||
|
hpicfXcvrVccHiAlarm,
|
||
|
hpicfXcvrVccLoAlarm,
|
||
|
hpicfXcvrVccHiWarn,
|
||
|
hpicfXcvrVccLoWarn,
|
||
|
hpicfXcvrBiasHiAlarm,
|
||
|
hpicfXcvrBiasLoAlarm,
|
||
|
hpicfXcvrBiasHiWarn,
|
||
|
hpicfXcvrBiasLoWarn,
|
||
|
hpicfXcvrPwrOutHiAlarm,
|
||
|
hpicfXcvrPwrOutLoAlarm,
|
||
|
hpicfXcvrPwrOutHiWarn,
|
||
|
hpicfXcvrPwrOutLoWarn,
|
||
|
hpicfXcvrRcvPwrHiAlarm,
|
||
|
hpicfXcvrRcvPwrLoAlarm,
|
||
|
hpicfXcvrRcvPwrHiWarn,
|
||
|
hpicfXcvrRcvPwrLoWarn,
|
||
|
hpicfXcvrDiagnosticsTimeStamp,
|
||
|
hpicfXcvrPhyLinkStatus,
|
||
|
hpicfXcvrPhySpeed,
|
||
|
hpicfXcvrPhyDuplex,
|
||
|
hpicfXcvrMdiPairACableStatus,
|
||
|
hpicfXcvrMdiPairACableLength,
|
||
|
hpicfXcvrMdiPairADistanceToFault,
|
||
|
hpicfXcvrMdiPairAPolaritySwap,
|
||
|
hpicfXcvrMdiPairASkew,
|
||
|
hpicfXcvrMdiPairBCableStatus,
|
||
|
hpicfXcvrMdiPairBCableLength,
|
||
|
hpicfXcvrMdiPairBDistanceToFault,
|
||
|
hpicfXcvrMdiPairBPolaritySwap,
|
||
|
hpicfXcvrMdiPairBSkew,
|
||
|
hpicfXcvrMdiPairCCableStatus,
|
||
|
hpicfXcvrMdiPairCCableLength,
|
||
|
hpicfXcvrMdiPairCDistanceToFault,
|
||
|
hpicfXcvrMdiPairCPolaritySwap,
|
||
|
hpicfXcvrMdiPairCSkew,
|
||
|
hpicfXcvrMdiPairDCableStatus,
|
||
|
hpicfXcvrMdiPairDCableLength,
|
||
|
hpicfXcvrMdiPairDDistanceToFault,
|
||
|
hpicfXcvrMdiPairDPolaritySwap,
|
||
|
hpicfXcvrMdiPairDSkew,
|
||
|
hpicfXcvrMdiPairABSwap,
|
||
|
hpicfXcvrMdiPairCDSwap
|
||
|
}
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"********* THIS GROUP IS DEPRECATED *********
|
||
|
|
||
|
A collection of objects representing transceiver
|
||
|
information.
|
||
|
|
||
|
This object has been deprecated and replaced with
|
||
|
hpicfXcvrInfoGroup1."
|
||
|
::= { hpicfXcvrGroups 1 }
|
||
|
|
||
|
hpicfXcvrInfoGroup1 OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
hpicfXcvrPortIndex,
|
||
|
hpicfXcvrPortDesc,
|
||
|
hpicfXcvrModel,
|
||
|
hpicfXcvrSerial,
|
||
|
hpicfXcvrType,
|
||
|
hpicfXcvrConnectorType,
|
||
|
hpicfXcvrWavelength,
|
||
|
hpicfXcvrTxDist,
|
||
|
hpicfXcvrDiagnostics,
|
||
|
hpicfXcvrDiagnosticsUpdate,
|
||
|
hpicfXcvrTemp,
|
||
|
hpicfXcvrVoltage,
|
||
|
hpicfXcvrBias,
|
||
|
hpicfXcvrRxPower,
|
||
|
hpicfXcvrTxPower,
|
||
|
hpicfXcvrAlarms,
|
||
|
hpicfXcvrErrors,
|
||
|
hpicfXcvrTempHiAlarm,
|
||
|
hpicfXcvrTempLoAlarm,
|
||
|
hpicfXcvrTempHiWarn,
|
||
|
hpicfXcvrTempLoWarn,
|
||
|
hpicfXcvrVccHiAlarm,
|
||
|
hpicfXcvrVccLoAlarm,
|
||
|
hpicfXcvrVccHiWarn,
|
||
|
hpicfXcvrVccLoWarn,
|
||
|
hpicfXcvrBiasHiAlarm,
|
||
|
hpicfXcvrBiasLoAlarm,
|
||
|
hpicfXcvrBiasHiWarn,
|
||
|
hpicfXcvrBiasLoWarn,
|
||
|
hpicfXcvrPwrOutHiAlarm,
|
||
|
hpicfXcvrPwrOutLoAlarm,
|
||
|
hpicfXcvrPwrOutHiWarn,
|
||
|
hpicfXcvrPwrOutLoWarn,
|
||
|
hpicfXcvrRcvPwrHiAlarm,
|
||
|
hpicfXcvrRcvPwrLoAlarm,
|
||
|
hpicfXcvrRcvPwrHiWarn,
|
||
|
hpicfXcvrRcvPwrLoWarn,
|
||
|
hpicfXcvrPhyLinkStatus,
|
||
|
hpicfXcvrPhySpeed,
|
||
|
hpicfXcvrPhyDuplex,
|
||
|
hpicfXcvrMdiPairACableStatus,
|
||
|
hpicfXcvrMdiPairACableLength,
|
||
|
hpicfXcvrMdiPairADistanceToFault,
|
||
|
hpicfXcvrMdiPairAPolaritySwap,
|
||
|
hpicfXcvrMdiPairASkew,
|
||
|
hpicfXcvrMdiPairBCableStatus,
|
||
|
hpicfXcvrMdiPairBCableLength,
|
||
|
hpicfXcvrMdiPairBDistanceToFault,
|
||
|
hpicfXcvrMdiPairBPolaritySwap,
|
||
|
hpicfXcvrMdiPairBSkew,
|
||
|
hpicfXcvrMdiPairCCableStatus,
|
||
|
hpicfXcvrMdiPairCCableLength,
|
||
|
hpicfXcvrMdiPairCDistanceToFault,
|
||
|
hpicfXcvrMdiPairCPolaritySwap,
|
||
|
hpicfXcvrMdiPairCSkew,
|
||
|
hpicfXcvrMdiPairDCableStatus,
|
||
|
hpicfXcvrMdiPairDCableLength,
|
||
|
hpicfXcvrMdiPairDDistanceToFault,
|
||
|
hpicfXcvrMdiPairDPolaritySwap,
|
||
|
hpicfXcvrMdiPairDSkew,
|
||
|
hpicfXcvrMdiPairABSwap,
|
||
|
hpicfXcvrMdiPairCDSwap,
|
||
|
hpicfXcvrDiagnosticsTimeTicks
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of objects representing transceiver
|
||
|
information."
|
||
|
::= { hpicfXcvrGroups 2 }
|
||
|
|
||
|
hpicfXcvrCompliances OBJECT IDENTIFIER ::=
|
||
|
{ hpicfXcvrConformance 2 }
|
||
|
|
||
|
hpicfXcvrCompliance MODULE-COMPLIANCE
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"********* THIS COMPLIANCE IS DEPRECATED *********
|
||
|
|
||
|
Describes the requirements for conformance to the
|
||
|
transceiver MIB.
|
||
|
|
||
|
This compliance section has been deprecated and
|
||
|
replaced with hpicfXcvrCompliance1."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS { hpicfXcvrInfoGroup }
|
||
|
::= { hpicfXcvrCompliances 1 }
|
||
|
|
||
|
hpicfXcvrCompliance1 MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Describes the requirements for conformance to the
|
||
|
transceiver MIB."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS { hpicfXcvrInfoGroup1 }
|
||
|
::= { hpicfXcvrCompliances 2 }
|
||
|