mibs/MIBS/hwg/HWg-WLD-MIB

163 lines
3.3 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- HWg-WLD MIB 1.01
-- History:
--
-- 1.00 27.11.2009 Marek Hummel - Created
-- 1.01 2.8.2010 Marek Hummel - Mib validation, add wldValue
-- 1.01-bis 12.5.2021 ChangeOID to avoid collisions with STE-MIB
--
HWg-WLD-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE FROM RFC-1212
Gauge, enterprises FROM RFC1155-SMI
DisplayString, sysName FROM RFC1213-MIB
TRAP-TYPE FROM RFC-1215;
--
-- Type Definitions
--
PositiveInteger ::= INTEGER (1..2147483647) -- 0x7FFF FFFF
SensorState ::= INTEGER {
invalid (0),
normal (1),
alarm (3)
}
SensorValue ::= INTEGER {
normal (0),
flooded (1),
disconnect (2),
invalid (3)
}
SensorSN ::= DisplayString (SIZE (0..16))
SensorName ::= DisplayString (SIZE (0..16))
SensorID ::= INTEGER
--
-- Node Definitions
--
hwgroup OBJECT IDENTIFIER ::= { enterprises 21796 }
x390 OBJECT IDENTIFIER ::= { hwgroup 4 }
hwgwld OBJECT IDENTIFIER ::= { x390 5 }
-- Application Info ------------------------------------------------------------
info OBJECT IDENTIFIER ::= { hwgwld 70 }
infoAddressMAC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..17))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MAC address in text form.
It is here to distinguish devices in trap messages."
::= { info 1 }
-- Sensors ---------------------------------------------------------------------
wldTable OBJECT-TYPE
SYNTAX SEQUENCE OF WldEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of sensor table entries. The number
of entries corresponds with number of detected sensors."
::= { hwgwld 4 }
wldEntry OBJECT-TYPE
SYNTAX WldEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing information applicable to a
particular sensor."
INDEX { wldIndex }
::= { wldTable 1 }
WldEntry ::= SEQUENCE {
wldIndex PositiveInteger,
wldName SensorName,
wldState SensorState,
wldSN SensorSN,
wldID SensorID,
wldValue SensorValue
}
wldIndex OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor index."
::= { wldEntry 1 }
wldName OBJECT-TYPE
SYNTAX SensorName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor name."
::= { wldEntry 2 }
wldState OBJECT-TYPE
SYNTAX SensorState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor state."
::= { wldEntry 3 }
wldSN OBJECT-TYPE
SYNTAX SensorSN
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor Serial number."
::= { wldEntry 4 }
wldID OBJECT-TYPE
SYNTAX SensorID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor ID."
::= { wldEntry 5 }
wldValue OBJECT-TYPE
SYNTAX SensorValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor value."
::= { wldEntry 6 }
-- Trap Definitions ------------------------------------------------------------
wldStateToAlarm TRAP-TYPE
ENTERPRISE hwgwld
VARIABLES { sysName, infoAddressMAC, wldIndex, wldName, wldState, wldSN, wldID, wldValue }
DESCRIPTION
"Sensor n changed to Alarm state."
::= 1
wldStateToNormal TRAP-TYPE
ENTERPRISE hwgwld
VARIABLES { sysName, infoAddressMAC, wldIndex, wldName, wldState, wldSN, wldID, wldValue }
DESCRIPTION
"Sensor n changed to Normal state."
::= 2
wldPeriodicAlarm TRAP-TYPE
ENTERPRISE hwgwld
VARIABLES { sysName, infoAddressMAC, wldIndex, wldName, wldState, wldSN, wldID, wldValue }
DESCRIPTION
"Sensor n periodic Alarm."
::= 3
END