mibs/MIBS/ibm/IMMALERT-MIB

1080 lines
45 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- ***************************************************************************
-- ***************************************************************************
--
-- File : immalert.mib
-- Description : Integrated Management Module mib for SNMP alerts
-- By : IBM
-- Version : 2.6
-- Date : July 26, 2011
--
--
-- Copyright (c) 2011 IBM All Rights Reserved.
--
--
-- Contains MIB description for:
-- This MIB is used by the IMM to generate traps
-- for Alert conditions detected by the management firmware.
-- ***************************************************************************
-- ***************************************************************************
-- ***************************************************************************
-- Revisions:
-- 07/28/2010 Version 2.0
-- Updated version info for imm2.mib and added portParity and portStopBits since these are supported in IMM2 hardware.
--
-- 09/13/2010 Version 2.1
-- added some Trap Types. Removed a couple of Trap Types. Changed some Trap Type names for consistency.
--
-- 10/20/2010 Version 2.2
-- add additional OIDs required to be sent with each SNMP Trap.
--
-- 02/24/2011 Version 2.3
-- change netfinitySupportProcessor to supportProcessor to be consistent with naming of "ibmProd 158" in other alert MIBs
--
-- 03/17/2011 Version 2.4
-- fix spelling of imm2alertMIB
--
-- 07/07/2011 Version 2.5
-- changes to make mib compatible with IMM1
--
-- 07/26/2011 Version 2.6
-- correction to "Alert Severity Value", range 0..65535
-- ***************************************************************************
IMMALERT-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE FROM RFC-1212
enterprises,
Counter, TimeTicks, IpAddress FROM RFC1155-SMI
mib-2,
DisplayString FROM RFC1213-MIB;
-- MIB for IMM Alerts starts here
ibm OBJECT IDENTIFIER ::= { enterprises 2 }
-- IBM products group
ibmProd OBJECT IDENTIFIER ::= { ibm 6 }
-- IBM Netfinity SP
supportProcessor OBJECT IDENTIFIER ::= { ibmProd 158 }
-- IBM IMM Alert
immalertMIB OBJECT IDENTIFIER ::= { supportProcessor 5 }
-- the nfspalt generic trap generator group
immtrapg OBJECT IDENTIFIER ::= { immalertMIB 1 }
altDateTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Timestamp of Local Date and Time when alert was generated"
::= { immtrapg 1 }
altSpTxtId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SP System Identification - Text Identification"
::= { immtrapg 3 }
altSysUuid OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host System UUID(Universal Unique ID)"
::= { immtrapg 5 }
altSysSern OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host System Serial Number"
::= { immtrapg 6 }
altPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alert Severity Value
- Critical Alert(0)
- Non-Critical Alert(2)
- System Alert(4)
- Recovery(8)"
::= { immtrapg 8 }
altMsgText OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alert Message Text"
::= { immtrapg 9 }
altMsgID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alert Message ID"
::= { immtrapg 10 }
altMsgIDPrefix OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alert Message ID"
::= { immtrapg 11 }
altHostContact OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Contact"
::= { immtrapg 12 }
altHostLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Location"
::= { immtrapg 13 }
altHostRoomID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Location - Room ID"
::= { immtrapg 14 }
altHostRackID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Location - Rack ID"
::= { immtrapg 15 }
altHostLowestUpos OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Location - Lowest U-position"
::= { immtrapg 16 }
altHostBladeBay OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Location - BladeBay"
::= { immtrapg 17 }
altEventID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Event Identifier"
::= { immtrapg 18 }
altServiceable OBJECT-TYPE
SYNTAX INTEGER {
notServiceable(0),
serviceableByIBM(1),
serviceableByCustomer(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serviceability information."
::= { immtrapg 19 }
altTest OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This event generated for test purposes."
::= { immtrapg 20 }
altFailingFRUs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ordered list of Failing FRU Numbers, separated by commas."
::= { immtrapg 21 }
altHostMTM OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Machine Type and Model for failing host."
::= { immtrapg 22 }
altAuxData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Auxiliary data that may be included for some events."
::= { immtrapg 23 }
-- ******************************************
-- Critical Traps
-- ******************************************
ibmSpTrapTempC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Temperature threshold exceeded."
::= 0
ibmSpTrapVoltC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Voltage threshold exceeded."
::= 1
ibmSpTrapPowerC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Power failure."
::= 4
ibmSpTrapHdC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Hard disk drive failure."
::= 5
ibmSpTrapFanC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Single Fan failure."
::= 11
ibmSpTrapIhcC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Incompatible hardware configuration."
::= 36
ibmSpTrapCPUC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: CPU Error."
::= 40
ibmSpTrapMemoryC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Memory Error."
::= 41
ibmSpTrapRdpsC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Redundant Power Supply failure."
::= 9
ibmSpTrapHardwareC TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Critical Alert: Other Failure - refer to Message ID for specific condition."
::= 50
-- ******************************************
-- Non-Critical Traps
-- ******************************************
ibmSpTrapRdpsN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: Redundant Power Supply failure."
::= 10
ibmSpTrapTempN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: Temperature threshold exceeded."
::= 12
ibmSpTrapVoltN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: Voltage threshold exceeded."
::= 13
ibmSpTrapPowerN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: Power."
::= 164
ibmSpTrapFanN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: Fan Error."
::= 165
ibmSpTrapCPUN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: CPU Error."
::= 42
ibmSpTrapMemoryN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: Memory Error."
::= 43
ibmSpTrapHardwareN TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Non-Critical Alert: Warning - refer to Message ID for specific condition."
::= 60
-- ******************************************
-- System Traps
-- ******************************************
ibmSpTrapRLogin TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"Sev-Off Alert: Event Remote Login."
::= 30
ibmSpTrapOsToS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: OS Timeout value exceeded."
::= 21
ibmSpTrapAppS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: Application Alert. Refer to Message ID for specific condition."
::= 22
ibmSpTrapPoffS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: Power Off."
::= 23
ibmSpTrapPonS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: Power On."
::= 24
ibmSpTrapBootS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: System Boot Failure."
::= 25
ibmSpTrapLdrToS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: OS Loader Timeout."
::= 26
ibmSpTrapPFAS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: Predictive Failure Analysis(PFA) information."
::= 27
ibmSpTrapSysLogS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: System Log 75% full."
::= 35
ibmSpTrapNwChangeS TRAP-TYPE
ENTERPRISE immalertMIB
VARIABLES
{
altDateTime,
altSpTxtId,
altSysUuid,
altSysSern,
altMsgID,
altMsgIDPrefix,
altPriority,
altMsgText,
altHostContact,
altHostLocation,
altHostRoomID,
altHostRackID,
altHostLowestUpos,
altHostBladeBay,
altEventID,
altServiceable,
altTest,
altFailingFRUs,
altHostMTM,
altAuxData
}
DESCRIPTION
"System Alert: Network change notification."
::= 37
END