LINKSYS-rlInterfaces DEFINITIONS ::= BEGIN
|
||
|
|
||
|
-- Title: LINKSYS Switch Interfaces Private
|
||
|
-- Version: 7.45
|
||
|
-- Date: 07 May 2006
|
||
|
-- 30-Nov-2004 Added type AutoNegCapabilitiesBits
|
||
|
-- 30-Nov-2004 Added fields swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities
|
||
|
-- swIfOperSpeedDuplexAutoNegotiationLocalCapabilities
|
||
|
-- swIfSpeedDuplexNegotiationRemoteCapabilities to swIfEntry
|
||
|
-- 22-Nov-2005 Obsoleted field swIfPhysAddressType
|
||
|
-- 22-Nov-2005 Added rlIfBaseMACAddressPerIfIndex
|
||
|
-- 30-Oct-2005 Added swIfExtTable
|
||
|
-- 30-Nov-2005 Added fields swIfAdminComboMode
|
||
|
-- swIfOperComboMode swIfExtTable to swIfEntry
|
||
|
-- 05-Dec-2005 Added rlFlowControlCascadeMode and rlFlowControlCascadeType
|
||
|
-- 23-Feb-2005 Added rlFlowControlRxPerSystem
|
||
|
-- 07-May-2006 Added rlCascadePortProtectionAction
|
||
|
-- 04-Jun-2006 Added multiple-auth enum to swIfHostMode
|
||
|
-- 11-Jun-2008 Added rlManagementIfIndex
|
||
|
-- 06-Jun-2009 Added rlIfClearPortMacAddresses
|
||
|
|
||
|
IMPORTS
|
||
|
rnd, rlIfInterfaces FROM LINKSYS-MIB
|
||
|
ifIndex, InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB
|
||
|
PortList FROM Q-BRIDGE-MIB
|
||
|
Unsigned32, Integer32, Counter32,
|
||
|
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
||
|
RowStatus, TruthValue, TEXTUAL-CONVENTION,
|
||
|
DisplayString FROM SNMPv2-TC;
|
||
|
|
||
|
|
||
|
swInterfaces MODULE-IDENTITY
|
||
|
LAST-UPDATED "201304010000Z" -- April 1, 2013
|
||
|
ORGANIZATION "Linksys LLC."
|
||
|
CONTACT-INFO
|
||
|
"www.linksys.com/business/support"
|
||
|
DESCRIPTION
|
||
|
"The MIB module describes the private MIB for Switch Interfaces supported
|
||
|
by Linksys MTS software and products."
|
||
|
REVISION "201304010000Z" -- April 1, 2013
|
||
|
DESCRIPTION
|
||
|
"Added MODULE-IDENTITY"
|
||
|
::= { rnd 43 }
|
||
|
|
||
|
|
||
|
-- These bits can be set in any combination (except unknown)
|
||
|
-- for field swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities
|
||
|
-- and will take affect when field swIfSpeedDuplexAutoNegotiation
|
||
|
-- will be set to enabled.
|
||
|
-- In addition these fields can be read for operative values of
|
||
|
-- auto negotiation capabilities
|
||
|
AutoNegCapabilitiesBits ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Auto negotiation capabilities bits."
|
||
|
SYNTAX BITS {
|
||
|
default(0),
|
||
|
unknown(1),
|
||
|
tenHalf(2),
|
||
|
tenFull(3),
|
||
|
fastHalf(4),
|
||
|
fastFull(5),
|
||
|
gigaHalf(6),
|
||
|
gigaFull(7),
|
||
|
tenGigaFull(8)
|
||
|
}
|
||
|
|
||
|
--
|
||
|
-- swTable
|
||
|
--
|
||
|
|
||
|
swIfTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SwIfEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Switch media specific information and configuration of the device
|
||
|
interfaces."
|
||
|
::= { swInterfaces 1 }
|
||
|
|
||
|
swIfEntry OBJECT-TYPE
|
||
|
SYNTAX SwIfEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines the contents of each line in the swIfTable table."
|
||
|
INDEX { swIfIndex }
|
||
|
::= { swIfTable 1 }
|
||
|
|
||
|
SwIfEntry ::= SEQUENCE {
|
||
|
swIfIndex INTEGER,
|
||
|
swIfPhysAddressType INTEGER,
|
||
|
swIfDuplexAdminMode INTEGER,
|
||
|
swIfDuplexOperMode INTEGER,
|
||
|
swIfBackPressureMode INTEGER,
|
||
|
swIfTaggedMode INTEGER,
|
||
|
swIfTransceiverType INTEGER,
|
||
|
swIfLockAdminStatus INTEGER,
|
||
|
swIfLockOperStatus INTEGER,
|
||
|
swIfType INTEGER,
|
||
|
swIfDefaultTag INTEGER,
|
||
|
swIfDefaultPriority INTEGER,
|
||
|
swIfStatus RowStatus,
|
||
|
swIfFlowControlMode INTEGER,
|
||
|
swIfSpeedAdminMode INTEGER,
|
||
|
swIfSpeedDuplexAutoNegotiation INTEGER,
|
||
|
swIfOperFlowControlMode INTEGER,
|
||
|
swIfOperSpeedDuplexAutoNegotiation INTEGER,
|
||
|
swIfOperBackPressureMode INTEGER,
|
||
|
swIfAdminLockAction INTEGER,
|
||
|
swIfOperLockAction INTEGER,
|
||
|
swIfAdminLockTrapEnable TruthValue,
|
||
|
swIfOperLockTrapEnable TruthValue,
|
||
|
swIfOperSuspendedStatus TruthValue,
|
||
|
swIfLockOperTrapCount INTEGER,
|
||
|
swIfLockAdminTrapFrequency INTEGER,
|
||
|
swIfReActivate TruthValue,
|
||
|
swIfAdminMdix INTEGER,
|
||
|
swIfOperMdix INTEGER,
|
||
|
swIfHostMode INTEGER,
|
||
|
swIfSingleHostViolationAdminAction INTEGER,
|
||
|
swIfSingleHostViolationOperAction INTEGER,
|
||
|
swIfSingleHostViolationAdminTrapEnable TruthValue,
|
||
|
swIfSingleHostViolationOperTrapEnable TruthValue,
|
||
|
swIfSingleHostViolationOperTrapCount INTEGER,
|
||
|
swIfSingleHostViolationAdminTrapFrequency INTEGER,
|
||
|
swIfLockLimitationMode INTEGER,
|
||
|
swIfLockMaxMacAddresses INTEGER,
|
||
|
swIfLockMacAddressesCount INTEGER,
|
||
|
swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities AutoNegCapabilitiesBits,
|
||
|
swIfOperSpeedDuplexAutoNegotiationLocalCapabilities AutoNegCapabilitiesBits,
|
||
|
swIfSpeedDuplexNegotiationRemoteCapabilities AutoNegCapabilitiesBits,
|
||
|
swIfAdminComboMode INTEGER,
|
||
|
swIfOperComboMode INTEGER,
|
||
|
swIfAutoNegotiationMasterSlavePreference INTEGER
|
||
|
}
|
||
|
|
||
|
|
||
|
swIfIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Index to the swIfTable. The interface defined by a
|
||
|
particular value of this index is the same interface as
|
||
|
identified by the same value of ifIndex (MIB II)."
|
||
|
::= { swIfEntry 1 }
|
||
|
|
||
|
swIfPhysAddressType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
default(1),
|
||
|
reserve(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS obsolete
|
||
|
DESCRIPTION
|
||
|
" This variable indicates whether the physical address assigned to this
|
||
|
interface should be the default one or be chosen from the set of
|
||
|
reserved physical addresses of the device."
|
||
|
DEFVAL { default }
|
||
|
::= { swIfEntry 2 }
|
||
|
|
||
|
swIfDuplexAdminMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
none(1),
|
||
|
half(2),
|
||
|
full(3)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable specifies whether this interface should operate in
|
||
|
half duplex or full duplex mode. This specification will take effect
|
||
|
only if swIfSpeedDuplexAutoNegotiation is disabled.
|
||
|
A value of 'none' is returned if a value of the variable
|
||
|
hasn't been set."
|
||
|
DEFVAL { none }
|
||
|
::= { swIfEntry 3 }
|
||
|
|
||
|
swIfDuplexOperMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
half(1),
|
||
|
full(2),
|
||
|
hybrid(3),
|
||
|
unknown(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" This variable indicates whether this interface operates in half
|
||
|
duplex or full duplex mode.
|
||
|
This variable can have the values hybrid or unknown
|
||
|
only for a trunk.
|
||
|
unknown - only if trunk operative status is not present."
|
||
|
::= { swIfEntry 4 }
|
||
|
|
||
|
swIfBackPressureMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enable(1),
|
||
|
disable(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether this interface activates back pressure
|
||
|
when congested."
|
||
|
::= { swIfEntry 5 }
|
||
|
|
||
|
swIfTaggedMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enable(1),
|
||
|
disable(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"If enable, this interface operates in tagged mode, i.e all frames sent
|
||
|
out through this interface will have the 802.1Q header.
|
||
|
If disabled the frames will not be tagged."
|
||
|
DEFVAL { disable }
|
||
|
::= { swIfEntry 6 }
|
||
|
|
||
|
swIfTransceiverType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
regular(1),
|
||
|
fiberOptics(2),
|
||
|
comboRegular(3),
|
||
|
comboFiberOptics(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" This variable indicates the transceiver type of this interface."
|
||
|
::= { swIfEntry 7 }
|
||
|
|
||
|
swIfLockAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
locked(1),
|
||
|
unlocked(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether this interface should operate in locked
|
||
|
or unlocked mode.
|
||
|
In unlocked mode the device learns all MAC addresses from this port and
|
||
|
forwards all frames arrived at this port. In locked mode no new MAC
|
||
|
addresses are learned and only frames with known source MAC
|
||
|
addresses are forwarded."
|
||
|
DEFVAL { unlocked }
|
||
|
::= { swIfEntry 8 }
|
||
|
|
||
|
swIfLockOperStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
locked(1),
|
||
|
unlocked(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable defines whether this interface operates in locked
|
||
|
or unlocked mode. It is locked in each of the following two cases:
|
||
|
1) if swLockAdminStatus is set to locked
|
||
|
2) no IP/IPX interface is defined over this interface and no
|
||
|
VLAN contains this interface.
|
||
|
In unlocked mode the device learns all MAC addresses from this port and
|
||
|
forwards all frames arrived at this port. In locked mode no new MAC
|
||
|
addresses are learned and only frames with known source MAC
|
||
|
addresses are forwarded."
|
||
|
::= { swIfEntry 9 }
|
||
|
|
||
|
swIfType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
eth10M(1),
|
||
|
eth100M(2),
|
||
|
eth1000M(3),
|
||
|
eth10G(4),
|
||
|
unknown(5)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" This variable specifies the type of interface."
|
||
|
::= { swIfEntry 10 }
|
||
|
|
||
|
swIfDefaultTag OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..4095)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable specifies the default VLAN tag which will be attached
|
||
|
to outgoing frames if swIfTaggedMode for this interface is enabled."
|
||
|
DEFVAL { 0 }
|
||
|
::= { swIfEntry 11 }
|
||
|
|
||
|
swIfDefaultPriority OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..7)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" This variable specifies the default port priority."
|
||
|
DEFVAL { 0 }
|
||
|
::= { swIfEntry 12 }
|
||
|
|
||
|
swIfStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of a table entry.
|
||
|
It is used to delete an entry from this table."
|
||
|
::= { swIfEntry 13 }
|
||
|
|
||
|
swIfFlowControlMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
on(1),
|
||
|
off(2),
|
||
|
autoNegotiation(3),
|
||
|
enabledRx(4),
|
||
|
enabledTx(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"on - Flow control will be enabled on this interface according to the
|
||
|
IEEE 802.3x standard.
|
||
|
off - Flow control is disabled.
|
||
|
autoNegotiation - Flow control will be enabled or disabled on this
|
||
|
interface. If enabled, it will operate as specified
|
||
|
by the IEEE 802.3x standard.
|
||
|
enabledRx - Flow control will be enabled on this interface for
|
||
|
recieved frames.
|
||
|
enabledTx - Flow control will be enabled on this interface for
|
||
|
transmitted frames.
|
||
|
An attempt to set this object to 'enabledRx(4)' or 'enabledTx(5)'
|
||
|
will fail on interfaces that do not support operation
|
||
|
at greater than 100 Mb/s.
|
||
|
In any case, flow control can work only if swIfDuplexOperMode is
|
||
|
full."
|
||
|
::= { swIfEntry 14}
|
||
|
|
||
|
swIfSpeedAdminMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable specifies the required speed of this interface in bits
|
||
|
per second. This specification will take effect only if
|
||
|
swIfSpeedDuplexAutoNegotiation is disabled.
|
||
|
A value of 10 is returned for 10G.
|
||
|
A value of 0 is returned if the value of the variable
|
||
|
hasn't been set."
|
||
|
DEFVAL { 0 }
|
||
|
::= { swIfEntry 15 }
|
||
|
|
||
|
swIfSpeedDuplexAutoNegotiation OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enabled(1),
|
||
|
disabled(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"If enabled the speed and duplex mode will be set by the device through
|
||
|
the autonegotiation process. Otherwise these characteristics will be
|
||
|
set according to the values of swIfSpeedAdminMode and
|
||
|
swIfSpeedDuplexAutoNegotiation."
|
||
|
::= { swIfEntry 16 }
|
||
|
|
||
|
swIfOperFlowControlMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
on(1),
|
||
|
off(2),
|
||
|
enabledRx(3),
|
||
|
enabledTx(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"on - Flow control is enabled on this interface according to the
|
||
|
IEEE 802.3x standard.
|
||
|
off - Flow control is disabled.
|
||
|
enabledRx - Flow control is enabled on this interface for
|
||
|
recieved frames.
|
||
|
enabledTx - Flow control is enabled on this interface for
|
||
|
transmitted frames."
|
||
|
::= { swIfEntry 17}
|
||
|
|
||
|
swIfOperSpeedDuplexAutoNegotiation OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enabled(1),
|
||
|
disabled(2),
|
||
|
hybrid(3),
|
||
|
unknown(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"If enabled the speed and duplex are determined by the device through
|
||
|
the autonegotiation process.
|
||
|
If disabled these characteristics are determined according to the values
|
||
|
of swIfSpeedAdminMode and swIfDuplexAdminMode.
|
||
|
hybrid - only for a trunk.
|
||
|
unknown - only for ports that there operative status is not present."
|
||
|
::= { swIfEntry 18 }
|
||
|
|
||
|
swIfOperBackPressureMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enable(1),
|
||
|
disable(2),
|
||
|
hybrid(3),
|
||
|
unknown(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the operative back pressure mode of
|
||
|
this interface."
|
||
|
::= { swIfEntry 19 }
|
||
|
|
||
|
swIfAdminLockAction OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
discard(1),
|
||
|
forwardNormal(2),
|
||
|
discardDisable(3)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates which action this interface should be taken
|
||
|
in locked mode and therefore relevant only in locked mode.
|
||
|
Possible actions:
|
||
|
discard(1) - every packet is dropped.
|
||
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
||
|
discardDisable(3) - drops the first packet and suspends the port."
|
||
|
--DEFVAL { discard } changed to product specific
|
||
|
::= { swIfEntry 20 }
|
||
|
|
||
|
|
||
|
swIfOperLockAction OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
discard(1),
|
||
|
forwardNormal (2),
|
||
|
discardDisable(3)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates which action this interface actually takes in
|
||
|
locked mode and therefore relevant only in locked mode.
|
||
|
Possible actions:
|
||
|
discard(1) - every packet is dropped.
|
||
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
||
|
discardDisable(3) - drops the first packet and suspends the port."
|
||
|
::= { swIfEntry 21 }
|
||
|
|
||
|
|
||
|
swIfAdminLockTrapEnable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether to create a SNMP trap in the locked mode."
|
||
|
--DEFVAL { false } changed to product specific
|
||
|
::= { swIfEntry 22 }
|
||
|
|
||
|
swIfOperLockTrapEnable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether a SNMP trap can be created in the
|
||
|
locked mode."
|
||
|
::= { swIfEntry 23 }
|
||
|
|
||
|
swIfOperSuspendedStatus OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether the port is suspended or not due to some
|
||
|
feature. After reboot this value is false"
|
||
|
::= { swIfEntry 24 }
|
||
|
|
||
|
swIfLockOperTrapCount OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0 .. 2147483647 )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the trap counter status per ifIndex
|
||
|
(i.e. number of received packets since the last trap sent due to a
|
||
|
packet which was received on this ifIndex). It's relevant only in locked
|
||
|
mode while trap is enabled."
|
||
|
::= { swIfEntry 25 }
|
||
|
|
||
|
swIfLockAdminTrapFrequency OBJECT-TYPE
|
||
|
SYNTAX INTEGER (1 .. 1000000)
|
||
|
-- UNITS "seconds"
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the minimal frequency (in seconds) of sending
|
||
|
a trap per ifIndex. It's relevant only in locked mode and in trap
|
||
|
enabled."
|
||
|
--DEFVAL { 10 } changed to product specific
|
||
|
::= { swIfEntry 26 }
|
||
|
|
||
|
swIfReActivate OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable reactivates (enables) an ifIndex (which was suspended)"
|
||
|
DEFVAL { false }
|
||
|
::= { swIfEntry 27 }
|
||
|
|
||
|
swIfAdminMdix OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
cross(1),
|
||
|
normal(2),
|
||
|
auto(3)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The configuration is on a physical port, not include trunks.
|
||
|
cross - The interface should force crossover.
|
||
|
normal - The interface should not force crossover.
|
||
|
auto - Auto mdix is enabled on the interface."
|
||
|
::= { swIfEntry 28 }
|
||
|
|
||
|
swIfOperMdix OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
cross(1),
|
||
|
normal(2),
|
||
|
unknown(3)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"cross - The interface is in crossover mode.
|
||
|
normal - The interface is not in crossover mode.
|
||
|
unknown - Only for port that its operative status is not present
|
||
|
or down."
|
||
|
::= { swIfEntry 29 }
|
||
|
|
||
|
swIfHostMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
single(1),
|
||
|
multiple(2),
|
||
|
multiple-auth(3)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the 802.1X host mode of a port. Relevant when the port's 802.1X control is auto.
|
||
|
In addtion multiple-auth was added."
|
||
|
DEFVAL { single }
|
||
|
::= { swIfEntry 30 }
|
||
|
|
||
|
swIfSingleHostViolationAdminAction OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
discard(1),
|
||
|
forwardNormal (2),
|
||
|
discardDisable(3)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates which action this interface should take in single authorized.
|
||
|
Possible actions:
|
||
|
discard - every packet is dropped.
|
||
|
forwardNormal - every packet is forwarded according to the DST address.
|
||
|
discardDisable - drops the first packet and suspends the port."
|
||
|
DEFVAL { discard }
|
||
|
::= { swIfEntry 31 }
|
||
|
|
||
|
swIfSingleHostViolationOperAction OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
discard(1),
|
||
|
forwardNormal (2),
|
||
|
discardDisable(3)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates which action this interface actually takes in single authorized.
|
||
|
Possible actions:
|
||
|
discard(1) - every packet is dropped.
|
||
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
||
|
discardDisable(3) - drops the first packet and suspends the port."
|
||
|
DEFVAL { discard }
|
||
|
::= { swIfEntry 32 }
|
||
|
|
||
|
swIfSingleHostViolationAdminTrapEnable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether to create a SNMP trap in single authorized."
|
||
|
DEFVAL { false }
|
||
|
::= { swIfEntry 33 }
|
||
|
|
||
|
swIfSingleHostViolationOperTrapEnable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether a SNMP trap can be created in the single authorized."
|
||
|
::= { swIfEntry 34 }
|
||
|
|
||
|
swIfSingleHostViolationOperTrapCount OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0 .. 2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the trap counter status per ifIndex
|
||
|
(i.e. number of received packets since the last trap sent due to a packet
|
||
|
which was received on this ifIndex). It's relevant only in single authorized
|
||
|
while trap is enabled."
|
||
|
::= { swIfEntry 35 }
|
||
|
|
||
|
swIfSingleHostViolationAdminTrapFrequency OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0 .. 1000000)
|
||
|
-- UNITS "seconds"
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the minimal frequency (in seconds) of sending a
|
||
|
trap per ifIndex. It's relevant only in single authorized and in trap enabled.
|
||
|
A value of 0 means that trap is disabled."
|
||
|
DEFVAL { 0 }
|
||
|
::= { swIfEntry 36 }
|
||
|
|
||
|
swIfLockLimitationMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
disabled(1),
|
||
|
dynamic(2),
|
||
|
secure-permanent(3),
|
||
|
secure-delete-on-reset(4)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates what is the learning limitation on the locked interface.
|
||
|
Possible values:
|
||
|
disabled - learning is stopped. The dynamic addresses associated with the
|
||
|
port are not aged out or relearned on other port as long as the port is
|
||
|
locked.
|
||
|
dynamic - dynamic addresses can be learned up to the maximum dynamic addresses
|
||
|
allowed on the port. Relearning and aging of the dynamic addresses are
|
||
|
enabled. The learned addresses aren't kept after reset.
|
||
|
secure-permanent - secure addresses can be learned up to the maximum addresses
|
||
|
allowed on the port. Relearning and aging of addresses are disabled.
|
||
|
The learned addresses are kept after reset.
|
||
|
secure-delete-on-reset - secure addresses can be learned up to the maximum addresses
|
||
|
allowed on the port. Relearning and aging of addresses are disabled.
|
||
|
The learned addresses are not kept after reset."
|
||
|
--DEFVAL { disabled } changed to product specific
|
||
|
::= { swIfEntry 37 }
|
||
|
|
||
|
swIfLockMaxMacAddresses OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0 .. 2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable defines the maximum number of dynamic addresses that
|
||
|
can be asscoiated with the locked interface. It isn't relevant in
|
||
|
disabled limitation mode."
|
||
|
DEFVAL { 1 }
|
||
|
::= { swIfEntry 38 }
|
||
|
|
||
|
swIfLockMacAddressesCount OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0 .. 2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the actual number of dynamic addresses that can
|
||
|
be asscoiated with the locked interface. It isn't relevant in disabled
|
||
|
limitation mode."
|
||
|
::= { swIfEntry 39 }
|
||
|
|
||
|
swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities OBJECT-TYPE
|
||
|
SYNTAX AutoNegCapabilitiesBits
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Administrative auto negotiation capabilities of the interface that can be advertised when
|
||
|
swIfSpeedDuplexAutoNegotiation is enabled.
|
||
|
default bit means advertise all the port's capabilities
|
||
|
according to its type."
|
||
|
DEFVAL { {default} }
|
||
|
::= { swIfEntry 40 }
|
||
|
|
||
|
swIfOperSpeedDuplexAutoNegotiationLocalCapabilities OBJECT-TYPE
|
||
|
SYNTAX AutoNegCapabilitiesBits
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Operative auto negotiation capabilities of the remote link.
|
||
|
unknown bit means that port operative status is not up."
|
||
|
::= { swIfEntry 41 }
|
||
|
|
||
|
swIfSpeedDuplexNegotiationRemoteCapabilities OBJECT-TYPE
|
||
|
SYNTAX AutoNegCapabilitiesBits
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Operative auto negotiation capabilities of the remote link.
|
||
|
unknown bit means that port operative status is not up,
|
||
|
or auto negotiation process not complete,
|
||
|
or remote link is not auto negotiation able."
|
||
|
::= { swIfEntry 42 }
|
||
|
|
||
|
swIfAdminComboMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
force-fiber(1),
|
||
|
force-copper(2),
|
||
|
prefer-fiber(3),
|
||
|
prefer-copper(4)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable specifies the administrative mode of a combo Ethernet interface."
|
||
|
DEFVAL { prefer-fiber }
|
||
|
::= { swIfEntry 43 }
|
||
|
|
||
|
swIfOperComboMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
fiber(1),
|
||
|
copper(2),
|
||
|
unknown(3)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable specifies the operative mode of a combo Ethernet interface."
|
||
|
::= { swIfEntry 44 }
|
||
|
|
||
|
swIfAutoNegotiationMasterSlavePreference OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
preferMaster(1),
|
||
|
preferSlave(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable specifies the administrative mode of the Maste-Slave preference in auto negotiation."
|
||
|
-- DEFVAL - according to MTSC parameter
|
||
|
::= { swIfEntry 45 }
|
||
|
|
||
|
|
||
|
|
||
|
--
|
||
|
-- swIfMibVersion
|
||
|
--
|
||
|
swIfMibVersion OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The swIfTable Mib's version, the current version is 3."
|
||
|
::= { swInterfaces 2 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- swIfPortLockSupport
|
||
|
--
|
||
|
swIfPortLockSupport OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
supported (1),
|
||
|
notSupported (2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"indicates if the locked port package is supported."
|
||
|
::= { swInterfaces 3 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- swIfPortLockActionSupport
|
||
|
--
|
||
|
swIfPortLockActionSupport OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"indicates which port lock actions are supported:
|
||
|
(bit 0 is the most significant bit)
|
||
|
bit 0 - discard
|
||
|
bit 1 - forwardNormal
|
||
|
bit 2 - discardDisable"
|
||
|
::= { swInterfaces 4 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- swIfPortLockTrapSupport
|
||
|
--
|
||
|
swIfPortLockTrapSupport OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(1))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"indicates with which port lock actions the trap option is supported
|
||
|
(e.g. discard indicates that trap is supported only when the portlock
|
||
|
action is discard):
|
||
|
(bit 0 is the most significant bit)
|
||
|
bit 0 - discard
|
||
|
bit 1 - forwardNormal
|
||
|
bit 2 - discardDisable"
|
||
|
::= { swInterfaces 5 }
|
||
|
|
||
|
|
||
|
|
||
|
--
|
||
|
-- swIfPortLockIfRangeTable
|
||
|
--
|
||
|
swIfPortLockIfRangeTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SwIfPortLockIfRangeEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Port lock interfaces range configuration"
|
||
|
::= { swInterfaces 6 }
|
||
|
|
||
|
swIfPortLockIfRangeEntry OBJECT-TYPE
|
||
|
SYNTAX SwIfPortLockIfRangeEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines the contents of each line in the swIfPortLockIfRangeTable table."
|
||
|
INDEX { swIfPortLockIfRangeIndex }
|
||
|
::= { swIfPortLockIfRangeTable 1 }
|
||
|
|
||
|
SwIfPortLockIfRangeEntry ::= SEQUENCE {
|
||
|
swIfPortLockIfRangeIndex INTEGER,
|
||
|
swIfPortLockIfRange PortList,
|
||
|
swIfPortLockIfRangeLockStatus INTEGER,
|
||
|
swIfPortLockIfRangeAction INTEGER,
|
||
|
swIfPortLockIfRangeTrapEn TruthValue,
|
||
|
swIfPortLockIfRangeTrapFreq INTEGER
|
||
|
}
|
||
|
|
||
|
swIfPortLockIfRangeIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Index to the swIfPortLockIfRangeTable."
|
||
|
::= { swIfPortLockIfRangeEntry 1 }
|
||
|
|
||
|
swIfPortLockIfRange OBJECT-TYPE
|
||
|
SYNTAX PortList
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The set of interfaces to which the port lock parameters should be configured"
|
||
|
::= { swIfPortLockIfRangeEntry 2 }
|
||
|
|
||
|
swIfPortLockIfRangeLockStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
locked(1),
|
||
|
unlocked(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether the interfaces range should operate in locked
|
||
|
or unlocked mode.
|
||
|
In unlocked mode the device learns all MAC addresses from these interfaces and
|
||
|
forwards all frames arrived at these interfaces. In locked mode no new MAC
|
||
|
addresses are learned and only frames with known source MAC
|
||
|
addresses are forwarded."
|
||
|
DEFVAL { unlocked }
|
||
|
::= { swIfPortLockIfRangeEntry 3 }
|
||
|
|
||
|
swIfPortLockIfRangeAction OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
discard(1),
|
||
|
forwardNormal(2),
|
||
|
discardDisable(3)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates which action for these interfaces should be take
|
||
|
in locked mode and therefore relevant only in locked mode.
|
||
|
Possible actions:
|
||
|
discard(1) - every packet is dropped.
|
||
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
||
|
discardDisable(3) - drops the first packet and suspends the port."
|
||
|
--DEFVAL { discard } changed to product specific
|
||
|
::= { swIfPortLockIfRangeEntry 4 }
|
||
|
|
||
|
swIfPortLockIfRangeTrapEn OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates whether to create a SNMP trap in the locked mode."
|
||
|
--DEFVAL { false } changed to product specific
|
||
|
::= { swIfPortLockIfRangeEntry 5 }
|
||
|
|
||
|
swIfPortLockIfRangeTrapFreq OBJECT-TYPE
|
||
|
SYNTAX INTEGER (1 .. 1000000)
|
||
|
-- UNITS "seconds"
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the minimal frequency (in seconds) of sending
|
||
|
a trap for these interfaces. It's relevant only in locked mode and in trap
|
||
|
enabled."
|
||
|
--DEFVAL { 10 } changed to product specific
|
||
|
::= { swIfPortLockIfRangeEntry 6 }
|
||
|
|
||
|
--
|
||
|
-- swIfExtTable
|
||
|
--
|
||
|
|
||
|
swIfExtTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SwIfExtEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Display information and configuration of the device interfaces."
|
||
|
::= { swInterfaces 7 }
|
||
|
|
||
|
swIfExtEntry OBJECT-TYPE
|
||
|
SYNTAX SwIfExtEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines the contents of each row in the swIfExtTable."
|
||
|
INDEX { ifIndex }
|
||
|
::= { swIfExtTable 1 }
|
||
|
|
||
|
SwIfExtEntry ::= SEQUENCE {
|
||
|
swIfExtSFPSpeed INTEGER
|
||
|
}
|
||
|
|
||
|
swIfExtSFPSpeed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
default(1),
|
||
|
eth100M(2),
|
||
|
eth1G(3)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Configure speed of an SFP Ethernet interface."
|
||
|
DEFVAL { default }
|
||
|
::= { swIfExtEntry 1 }
|
||
|
|
||
|
--
|
||
|
-- rlIfInterfaces
|
||
|
--
|
||
|
|
||
|
rlIfMibVersion OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"MIB's version, the current version is 1."
|
||
|
::= { rlIfInterfaces 1 }
|
||
|
|
||
|
rlIfNumOfPhPorts OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Total number of physical ports on this device
|
||
|
(including all stack units)"
|
||
|
::= { rlIfInterfaces 2 }
|
||
|
|
||
|
rlIfMapOfOnPhPorts OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each bit in this octet string indicates that the correspondig port's
|
||
|
ifOperStatus is ON if set.
|
||
|
The mapping of port number to bits in this octet string is as follows:
|
||
|
The port with the L2 interface number 1 is mapped to the least
|
||
|
significant bit of the 1st octet, the port with L2 ifNumber 2 to the
|
||
|
next significant bit in the 1st octet, port 8 to the most-significant
|
||
|
bit of the in the 1st octet, port 9 to the least
|
||
|
significant bit of the 2nd octet, etc. and in general,
|
||
|
port n to bit corresponding to 2**((n mod 8) -1) in byte n/8 + 1"
|
||
|
::= { rlIfInterfaces 3 }
|
||
|
|
||
|
rlIfClearPortMibCounters OBJECT-TYPE
|
||
|
SYNTAX PortList
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each bit that is set in this portList represent a port that
|
||
|
its mib counters should be reset."
|
||
|
::= { rlIfInterfaces 4 }
|
||
|
|
||
|
rlIfNumOfUserDefinedPorts OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of user defined ports on this device."
|
||
|
::= { rlIfInterfaces 5 }
|
||
|
|
||
|
rlIfFirstOutOfBandIfIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"First ifIndex of out-of-band port.
|
||
|
This scalar exists only the device has out of band ports."
|
||
|
::= { rlIfInterfaces 6 }
|
||
|
|
||
|
rlIfNumOfLoopbackPorts OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of loopback ports on this device."
|
||
|
::= { rlIfInterfaces 7 }
|
||
|
|
||
|
rlIfFirstLoopbackIfIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"First ifIndex of loopback port.
|
||
|
This scalar will exists only if rlIfNumOfLoopbackPorts
|
||
|
is different from 0."
|
||
|
::= { rlIfInterfaces 8 }
|
||
|
|
||
|
rlIfExistingPortList OBJECT-TYPE
|
||
|
SYNTAX PortList
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates which ports/trunks exist in the system.
|
||
|
It doesn't indicate which are present."
|
||
|
::= { rlIfInterfaces 9 }
|
||
|
|
||
|
rlIfBaseMACAddressPerIfIndex OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates if the system will assign a unique MAC per Ethernet port or not."
|
||
|
::= { rlIfInterfaces 10 }
|
||
|
|
||
|
rlFlowControlCascadeMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enabled(1),
|
||
|
disabled(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"enable disable flow control on cascade ports"
|
||
|
::= { rlIfInterfaces 11 }
|
||
|
|
||
|
rlFlowControlCascadeType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
internalonly(1),
|
||
|
internalexternal(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"define which type of ports will be affected by flow control on cascade ports"
|
||
|
::= { rlIfInterfaces 12 }
|
||
|
|
||
|
rlFlowControlRxPerSystem OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"define if flow control RX is supported per system."
|
||
|
::= { rlIfInterfaces 13 }
|
||
|
|
||
|
rlCascadePortProtectionAction OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"As a result of this set all of the local cascade ports
|
||
|
will stop being consider unstable and will be force up."
|
||
|
::= { rlIfInterfaces 14 }
|
||
|
|
||
|
rlManagementIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specify L2 bound management interface index in a single IP address system
|
||
|
when configurable management interface is supported."
|
||
|
::= { rlIfInterfaces 15 }
|
||
|
|
||
|
rlIfClearStackPortsCounters OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"As a result of this set all counters of
|
||
|
all external cascade ports will be cleared."
|
||
|
::= { rlIfInterfaces 16 }
|
||
|
|
||
|
rlIfClearPortMacAddresses OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndexOrZero
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"if port is non secure, its all dynamic MAC addresses are cleared.
|
||
|
if port is secure, its all secure MAC addresses which have learned or configured are cleared."
|
||
|
::= { rlIfInterfaces 17 }
|
||
|
|
||
|
rlIfCutThroughPacketLength OBJECT-TYPE
|
||
|
SYNTAX INTEGER (257 .. 16383)
|
||
|
MAX-ACCESS read-write
|
||
|
-- Obsolete
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The default packet length that is assigned to a packet in the
|
||
|
Cut-Through mode."
|
||
|
DEFVAL { 1522 }
|
||
|
::= { rlIfInterfaces 18 }
|
||
|
|
||
|
rlIfCutPriorityZero OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 0."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 19 }
|
||
|
|
||
|
rlIfCutPriorityOne OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 1."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 20 }
|
||
|
|
||
|
rlIfCutPriorityTwo OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 2."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 21 }
|
||
|
|
||
|
rlIfCutPriorityThree OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 3."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 22 }
|
||
|
|
||
|
rlIfCutPriorityFour OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 4."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 23 }
|
||
|
|
||
|
rlIfCutPriorityFive OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 5."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 24 }
|
||
|
|
||
|
rlIfCutPrioritySix OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 6."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 25 }
|
||
|
|
||
|
rlIfCutPrioritySeven OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-Through for priority 7."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 26 }
|
||
|
|
||
|
rlIfCutThroughTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF RlIfCutThroughEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Information and configuration of cut-through feature."
|
||
|
::= { rlIfInterfaces 27 }
|
||
|
|
||
|
rlIfCutThroughEntry OBJECT-TYPE
|
||
|
SYNTAX RlIfCutThroughEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines the contents of each line in the swIfTable table."
|
||
|
INDEX { swIfIndex }
|
||
|
::= { rlIfCutThroughTable 1 }
|
||
|
|
||
|
RlIfCutThroughEntry ::= SEQUENCE {
|
||
|
rlIfCutThroughPriorityEnable TruthValue,
|
||
|
rlIfCutThroughUntaggedEnable TruthValue,
|
||
|
rlIfCutThroughOperMode TruthValue
|
||
|
}
|
||
|
|
||
|
rlIfCutThroughPriorityEnable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-through for a priority for an interface."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfCutThroughEntry 1 }
|
||
|
|
||
|
rlIfCutThroughUntaggedEnable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable or disable cut-through for untagged packets for an interface."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfCutThroughEntry 2 }
|
||
|
|
||
|
rlIfCutThroughOperMode OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Operational mode of spesific cut-through interface."
|
||
|
::= { rlIfCutThroughEntry 3 }
|
||
|
|
||
|
rlCutThroughPacketLength OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The default packet length that is assigned to a packet in the
|
||
|
Cut-Through mode."
|
||
|
::= { rlIfInterfaces 28 }
|
||
|
|
||
|
rlCutThroughPacketLengthAfterReset OBJECT-TYPE
|
||
|
SYNTAX INTEGER (257 .. 16383)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The default packet length that is assigned to a packet in the
|
||
|
Cut-Through mode after reset."
|
||
|
DEFVAL { 1522 }
|
||
|
::= { rlIfInterfaces 29 }
|
||
|
|
||
|
rlCutThroughEnable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Cut-Through global enable mode."
|
||
|
::= { rlIfInterfaces 30 }
|
||
|
|
||
|
rlCutThroughEnableAfterReset OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Cut-Through global enable mode after reset."
|
||
|
DEFVAL { false }
|
||
|
::= { rlIfInterfaces 31 }
|
||
|
|
||
|
rlFlowControlMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
send-receive(1),
|
||
|
receive-only(2)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Define which mode will be enabled on flow control enabled ports.
|
||
|
The interfaces with enabled flow control will receive pause frames, but will not send flow control pause
|
||
|
frames
|
||
|
Send-receive: The interfaces with enabled flow control will receive and send pause frames.
|
||
|
Receive-only: The interfaces with enabled flow control will receive pause frames, but will not send flow
|
||
|
control pause frames."
|
||
|
|
||
|
::= { rlIfInterfaces 32 }
|
||
|
|
||
|
|
||
|
|
||
|
END
|
||
|
|
||
|
|