-- PPC MIB
|
||
|
-- ====================================================================
|
||
|
-- Revision History
|
||
|
-- v0.13 2011-11-10 Gavin Zhao created, Lilinhua modified
|
||
|
-- *************************NMC v0.0.1.7***********************************
|
||
|
-- v0.14 2011-11-18 Lilinhua
|
||
|
-- 1. Modify string "ppcTrap" to "eppcTrap"
|
||
|
-- 2012-02-09 Lilinhua
|
||
|
-- 1. Modify upsESystemFaultCode's description "The warning code of UPS" to "The fault code of UPS".
|
||
|
-- *************************NMC v1.1.0.4************************************
|
||
|
-- v0.15 2012-07-20 Lilinhua
|
||
|
-- 1. upsEShutdownWarningPeriodInterval, modify access from read-only to read-write.
|
||
|
-- 2. upsEShutdownwarningPeriodTime, add unit second.
|
||
|
-- 2012-07-31 Lilinhua
|
||
|
-- 1. Modify upsEBatteryTestElapsedTime's format from hh:mm:ss.ss to hh:mm:ss
|
||
|
-- 2012-08-09 Lilinhua
|
||
|
-- 1. Modify values of upsEModuleWorkingMode as upsESystemStatus's.
|
||
|
-- *************************NMC v1.1.0.6************************************
|
||
|
-- 2012-08-27 Lilinhua
|
||
|
-- 1. Modify "Moudles" to "Modules", advised by Beth.
|
||
|
-- 2. Modify module name as phase name "upsEModuleOutputCurrentR", "upsEModuleOutputWattR", "upsEModuleOutputLoadR".
|
||
|
-- 3. Add Convert module item "upsEModuleTrapState(12)".
|
||
|
-- 4. Add Convert module item "upsEModuleConfigOutputVA(13)".
|
||
|
-- 5. Add Convert module item "upsEModuleOutputCurrentS(14)", "upsEModuleOutputCurrentT(15)".
|
||
|
-- 6. Add Convert module item "upsEModuleOutputWattS(16)", "upsEModuleOutputWattT(17)".
|
||
|
-- 7. Add Convert module item "upsEModuleOutputLoadS(18)", "upsEModuleOutputLoadT(19)".
|
||
|
-- 8. Add Convert module item "upsEModuleOutputVAR(20)", "upsEModuleOutputVAS(21)", "upsEModuleOutputVAT(22)".
|
||
|
-- 9. Modify upsETrapState max length from 255 to 127.
|
||
|
-- *************************NMC v1.1.0.6************************************
|
||
|
-- 2012-08-27 Lilinhua
|
||
|
-- 1. Modify trap description of Overload, OverTemperature.
|
||
|
-- *************************NMC v1.3.0.0************************************
|
||
|
-- 2013-06-21 Lilinhua
|
||
|
-- 1. Add two upsEShutdownEvents: "belowCapacityLimit(11), belowRemainTimeLimit(12)".
|
||
|
-- 2. Add 4 traps: upsEBelowCapacityLimit, upsENotBelowCapacityLimit, upsEBelowRemainTimeLimit, upsENotBelowRemainTimeLimit.
|
||
|
-- 3. Add 2 config data: upsESystemConfigBelowCapacityLimit, upsESystemConfigBelowRemainTimeLimit.
|
||
|
-- 4. Modify upsETrapState's description: "trap 2(battery on)" to "trap 7(battery on)".
|
||
|
-- *************************NMC v1.4.0.3************************************
|
||
|
-- 2014-10-15 Lilinhua
|
||
|
-- 1. Modify descriptions of "upsEEnvironmentTemperatureHighSetPoint, upsEEnvironmentHumidityHighSetPoint,
|
||
|
-- upsEEnvironmentTemperatureLowSetPoint, upsEEnvironmentHumidityLowSetPoint".
|
||
|
-- *************************NMC v1.5.0.4************************************
|
||
|
-- v0.16 2015-01-05 Lilinhua
|
||
|
-- 1. Modify MIB for add Load segment.
|
||
|
|
||
|
|
||
|
EPPC-MIB DEFINITIONS ::= BEGIN
|
||
|
IMPORTS
|
||
|
TRAP-TYPE
|
||
|
FROM RFC-1215
|
||
|
DisplayString
|
||
|
FROM SNMPv2-TC
|
||
|
OBJECT-TYPE
|
||
|
FROM RFC-1212
|
||
|
enterprises,Counter, IpAddress
|
||
|
FROM RFC1155-SMI
|
||
|
PositiveInteger,NonNegativeInteger
|
||
|
FROM UPS-MIB;
|
||
|
|
||
|
ppc OBJECT IDENTIFIER ::= { enterprises 935 }
|
||
|
|
||
|
device OBJECT IDENTIFIER ::= { ppc 10 }
|
||
|
upsAgent OBJECT IDENTIFIER ::= { device 1 }
|
||
|
|
||
|
upsE OBJECT IDENTIFIER ::= { upsAgent 1 }
|
||
|
upsETraps OBJECT IDENTIFIER ::= { upsAgent 2 }
|
||
|
upsEIdentity OBJECT IDENTIFIER ::= { upsE 1 }
|
||
|
upsESystemSummary OBJECT IDENTIFIER ::= { upsE 2 }
|
||
|
upsEBatterySystem OBJECT IDENTIFIER ::= { upsE 3 }
|
||
|
upsEPowerConverterSystem OBJECT IDENTIFIER ::= { upsE 4 }
|
||
|
upsELoadSegment OBJECT IDENTIFIER ::= { upsE 5 }
|
||
|
upsEEnvironment OBJECT IDENTIFIER ::= { upsE 6 }
|
||
|
upsEBatteryTest OBJECT IDENTIFIER ::= { upsE 7 }
|
||
|
upsEControl OBJECT IDENTIFIER ::= { upsE 8 }
|
||
|
upsETrapControl OBJECT IDENTIFIER ::= { upsE 9 }
|
||
|
|
||
|
--========================================================================
|
||
|
--upsEIdentity
|
||
|
--========================================================================
|
||
|
|
||
|
upsEIdentityManufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The name of the UPS manufacturer."
|
||
|
::= { upsEIdentity 1 }
|
||
|
|
||
|
upsEIdentityModel OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The UPS Model designation."
|
||
|
::= { upsEIdentity 2 }
|
||
|
|
||
|
upsEIdentityUPSFirmwareVerison OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The UPS firmware/software version(s)."
|
||
|
::= { upsEIdentity 3 }
|
||
|
|
||
|
upsEIndentityUPSSerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "optional.
|
||
|
Most UPS don't supply the value of UPS serial No."
|
||
|
::= { upsEIdentity 4 }
|
||
|
|
||
|
upsEIdentityDescription OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A string to identify the UPS. This object should be
|
||
|
set by the administrator."
|
||
|
::= { upsEIdentity 5 }
|
||
|
|
||
|
upsEIdentityAgentSoftwareVerison OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The Network Management Card software/firmware version.
|
||
|
This variable may or may not have the same value as
|
||
|
upsEIdentGroupUPSSoftwareVersion in some implementations."
|
||
|
::= { upsEIdentity 6 }
|
||
|
|
||
|
upsEIdentityAttachedDevices OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A string identifying the devices attached to the output(s)
|
||
|
of the UPS. This object should be set by the administrator"
|
||
|
::= { upsEIdentity 7 }
|
||
|
|
||
|
--========================================================================
|
||
|
--upsESystemSummary
|
||
|
--========================================================================
|
||
|
|
||
|
upsESystemStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { power-on ( 1 ) , stand-by( 2 ) , by-pass ( 3 ) ,
|
||
|
line( 4 ) , battery ( 5 ) , battery-test ( 6 ) , fault ( 7 ) ,
|
||
|
converter ( 8 ) , eco ( 9 ) , shutdown ( 10 ) , on-booster ( 11 ) , on-reducer ( 12 ) , other( 13 ) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The indication of UPS system status."
|
||
|
::= { upsESystemSummary 1 }
|
||
|
|
||
|
upsESystemTemperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The temperature of UPS presented in 0.1 degree."
|
||
|
::= { upsESystemSummary 2 }
|
||
|
|
||
|
upsESystemWarningCode OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The warning code of UPS. Please refer the warning table
|
||
|
of 'Q6' for details."
|
||
|
::= { upsESystemSummary 3 }
|
||
|
|
||
|
upsESystemFaultCode OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The fault code of UPS.Please refer the fault code
|
||
|
of 'Q6' for details."
|
||
|
::= { upsESystemSummary 4 }
|
||
|
|
||
|
upsESystemConfigInputVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal input voltage presented in 0.1 V. On those
|
||
|
systems which support read-write access to this object, if there is an
|
||
|
attempt to set this variable to a value that is not supported,
|
||
|
the request must be rejected and the agent shall respond with an
|
||
|
appropriate error message, i.e., badValue for SNMPv1, or
|
||
|
inconsistentValue for SNMPv2."
|
||
|
::= { upsESystemSummary 5 }
|
||
|
|
||
|
upsESystemConfigInputFrequence OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The nominal input frequency presented in 0.1 Hz. On those systems which support
|
||
|
read-write access to this object, if there is an attempt to
|
||
|
set this variable to a value that is not supported, the request
|
||
|
must be rejected and the agent shall respond with an appropriate
|
||
|
error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2."
|
||
|
::= { upsESystemSummary 6 }
|
||
|
|
||
|
upsESystemConfigOutputVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal output voltage presented in 0.1V. On those systems
|
||
|
which support read-write access to this object, if there is an
|
||
|
attempt to set this variable to a value that is not supported,
|
||
|
the request must be rejected and the agent shall respond with an
|
||
|
appropriate error message, i.e., badValue for SNMPv1, or
|
||
|
inconsistentValue for SNMPv2"
|
||
|
::= { upsESystemSummary 7 }
|
||
|
|
||
|
upsESystemConfigOutputFrequency OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The nominal output frequency presented in 0.1Hz. On those systems which support
|
||
|
read-write access to this object, if there is an attempt to set
|
||
|
this variable to a value that is not supported, the request must
|
||
|
be rejected and the agent shall respond with an appropriate error
|
||
|
message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2."
|
||
|
::= { upsESystemSummary 8 }
|
||
|
|
||
|
upsESystemConfigOutputVA OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
||
|
::= { upsESystemSummary 9 }
|
||
|
|
||
|
upsESystemConfigOutputPower OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal true power rating presented in W ."
|
||
|
::= { upsESystemSummary 10 }
|
||
|
|
||
|
upsESystemConfigOutputLoadHighSetPoint OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The maximum output load allowed before the load is too high for
|
||
|
UPS operation "
|
||
|
::= { upsESystemSummary 11 }
|
||
|
|
||
|
upsESystemConfigOverTemperatureSetPoint OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The maximum temperature allowed before the UPS
|
||
|
operation temperature is too high, presented in 0.1 degree."
|
||
|
::= { upsESystemSummary 12 }
|
||
|
|
||
|
upsESystemInputSourceNum OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The present external source of input power."
|
||
|
::= { upsESystemSummary 13 }
|
||
|
|
||
|
upsESystemInputLineBads OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of times the Input was out of tolerance in voltage or frequency.
|
||
|
Its value should be initialized 0 after agent restarting. "
|
||
|
::= { upsESystemSummary 14 }
|
||
|
|
||
|
upsESystemInputNumPhases OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of input phase utilized is this device, serves as the table index.
|
||
|
This value indicate the device initialized feature."
|
||
|
::= { upsESystemSummary 15 }
|
||
|
|
||
|
upsESystemInputTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsSystemInputEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A list of input table entries. The number of entries is given by the
|
||
|
value of upsESystemInputNumPhase."
|
||
|
::= { upsESystemSummary 16 }
|
||
|
|
||
|
upsESystemInputEntry OBJECT-TYPE
|
||
|
SYNTAX UpsSystemInputEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular input line."
|
||
|
INDEX { upsESystemInputPhase }
|
||
|
::= { upsESystemInputTable 1 }
|
||
|
|
||
|
UpsSystemInputEntry ::= SEQUENCE {
|
||
|
upsESystemInputPhase PositiveInteger,
|
||
|
upsESystemInputFrequency NonNegativeInteger,
|
||
|
upsESystemInputVoltage NonNegativeInteger,
|
||
|
upsESystemInputCurrent NonNegativeInteger,
|
||
|
upsESystemInputWatts NonNegativeInteger
|
||
|
}
|
||
|
|
||
|
|
||
|
upsESystemInputPhase OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger( 1 .. 3 )
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of the phase. Serves as index for input table"
|
||
|
::= { upsESystemInputEntry 1 }
|
||
|
|
||
|
|
||
|
upsESystemInputFrequency OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured input frquency from the UPS meters in 0.1Hz."
|
||
|
::= { upsESystemInputEntry 2 }
|
||
|
|
||
|
|
||
|
upsESystemInputVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured input voltage from the UPS meters in 0.1 volts"
|
||
|
::= { upsESystemInputEntry 3 }
|
||
|
|
||
|
|
||
|
upsESystemInputCurrent OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured input mandatory from the UPS meters in 0.1 amps."
|
||
|
::= { upsESystemInputEntry 4 }
|
||
|
|
||
|
|
||
|
upsESystemInputWatts OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured input real power in watts."
|
||
|
::= { upsESystemInputEntry 5 }
|
||
|
|
||
|
upsESystemOutputNumPhase OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of metered output phases, serves as the table index.
|
||
|
This value indicate the device initialized feature."
|
||
|
::= { upsESystemSummary 17 }
|
||
|
|
||
|
upsESystemOutputTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsSystemOutputEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A list of output table entries. The number of entries is given
|
||
|
by the value of upsESystemOutputNumPhase."
|
||
|
::= { upsESystemSummary 18 }
|
||
|
|
||
|
upsESystemOutputEntry OBJECT-TYPE
|
||
|
SYNTAX UpsSystemOutputEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular line."
|
||
|
INDEX { upsESystemOutputPhase }
|
||
|
::= { upsESystemOutputTable 1 }
|
||
|
|
||
|
UpsSystemOutputEntry ::= SEQUENCE {
|
||
|
upsESystemOutputPhase PositiveInteger,
|
||
|
upsESystemOutputFrequency NonNegativeInteger,
|
||
|
upsESystemOutputVoltage NonNegativeInteger,
|
||
|
upsESystemOutputCurrent NonNegativeInteger,
|
||
|
upsESystemOutputWatts NonNegativeInteger,
|
||
|
upsESystemOutputVA NonNegativeInteger,
|
||
|
upsESystemOutputLoad NonNegativeInteger
|
||
|
}
|
||
|
|
||
|
|
||
|
upsESystemOutputPhase OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of the phase. Serves as index for output table"
|
||
|
::= { upsESystemOutputEntry 1 }
|
||
|
|
||
|
|
||
|
upsESystemOutputFrequency OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured output frequency from the UPS meters in 0.1Hz."
|
||
|
::= { upsESystemOutputEntry 2 }
|
||
|
|
||
|
|
||
|
upsESystemOutputVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured output voltage from the UPS meters in 0.1 volts"
|
||
|
::= { upsESystemOutputEntry 3 }
|
||
|
|
||
|
|
||
|
upsESystemOutputCurrent OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured output mandatory from the UPS meters in 0.1 amps."
|
||
|
::= { upsESystemOutputEntry 4 }
|
||
|
|
||
|
|
||
|
upsESystemOutputWatts OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured output real power in watts."
|
||
|
::= { upsESystemOutputEntry 5 }
|
||
|
|
||
|
upsESystemOutputVA OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured output real complex power in VA."
|
||
|
::= { upsESystemOutputEntry 6 }
|
||
|
|
||
|
|
||
|
upsESystemOutputLoad OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The UPS output load in percent of rated capacity."
|
||
|
::= { upsESystemOutputEntry 7 }
|
||
|
|
||
|
upsESystemBypassNumPhase OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of bypass phases, serves as the table index.
|
||
|
This value indicate the device initialized feature"
|
||
|
::= { upsESystemSummary 19 }
|
||
|
|
||
|
upsESystemBypassTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsSystemBypassEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A list of bypass table entries. The number of entries is given by the
|
||
|
value of upsESystemBypassNumPhase."
|
||
|
::= { upsESystemSummary 20 }
|
||
|
|
||
|
|
||
|
upsESystemBypassEntry OBJECT-TYPE
|
||
|
SYNTAX UpsSystemBypassEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular line."
|
||
|
INDEX { upsESystemBypassPhase }
|
||
|
::= { upsESystemBypassTable 1 }
|
||
|
|
||
|
UpsSystemBypassEntry ::= SEQUENCE {
|
||
|
upsESystemBypassPhase PositiveInteger,
|
||
|
upsESystemBypassFrequency NonNegativeInteger,
|
||
|
upsESystemBypassVoltage NonNegativeInteger,
|
||
|
upsESystemBypassCurrent NonNegativeInteger,
|
||
|
upsESystemBypassWatts NonNegativeInteger
|
||
|
}
|
||
|
|
||
|
|
||
|
upsESystemBypassPhase OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of the phase. Serves as index for bypass table"
|
||
|
::= { upsESystemBypassEntry 1 }
|
||
|
|
||
|
|
||
|
upsESystemBypassFrequency OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured bypass frequency from the UPS meters in 0.1 Hz."
|
||
|
::= { upsESystemBypassEntry 2 }
|
||
|
|
||
|
|
||
|
upsESystemBypassVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured bypass voltage from the UPS meters in 0.1 volts"
|
||
|
::= { upsESystemBypassEntry 3 }
|
||
|
|
||
|
|
||
|
upsESystemBypassCurrent OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured bypass mandatory from the UPS meters in 0.1 amps"
|
||
|
::= { upsESystemBypassEntry 4 }
|
||
|
|
||
|
|
||
|
upsESystemBypassWatts OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured input real power in watts."
|
||
|
::= { upsESystemBypassEntry 5 }
|
||
|
|
||
|
|
||
|
upsESystemConfigBelowCapacityLimit OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The UPS batteries capacity(%) limit for shutdown"
|
||
|
::= { upsESystemSummary 21 }
|
||
|
|
||
|
upsESystemConfigBelowRemainTimeLimit OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The UPS batteries backup time(minute) limit for shutdown"
|
||
|
::= { upsESystemSummary 22 }
|
||
|
|
||
|
--========================================================================
|
||
|
--upsEBatterySystem
|
||
|
--========================================================================
|
||
|
|
||
|
upsEBatteryStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown ( 1 ) , batteryNormal ( 2 ) , batteryLow ( 3 ) ,
|
||
|
batteryDepleted ( 4 ) , batteryDischarging ( 5 ) , batteryFailure ( 6 ) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION " The status of UPS battery, a value of batteryLow indicates
|
||
|
that the battery-low status bit has been set from device.
|
||
|
A value of batteryDepleted indicates that the UPS will be
|
||
|
unable to sustain the present load when and if the utility
|
||
|
power is lost (including the possibility that the utility
|
||
|
power is mandatoryly absent and the UPS is unable to sustain
|
||
|
the output)"
|
||
|
::= { upsEBatterySystem 1 }
|
||
|
|
||
|
upsESecondsOnBattery OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "If the unit is on battery power, the elapsed time
|
||
|
since the UPS last switched to battery power, or the
|
||
|
time since the network management subsystem was last
|
||
|
restarted, whichever is less. 0 shall be returned
|
||
|
if the unit is not on battery power"
|
||
|
::= { upsEBatterySystem 2 }
|
||
|
|
||
|
upsEBatteryEstimatedMinutesRemaining OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An estimate of the time to battery charge depletion
|
||
|
under the present load conditions if the utility power
|
||
|
is off and remains off, or if it were to be lost and
|
||
|
remain off."
|
||
|
::= { upsEBatterySystem 3 }
|
||
|
|
||
|
upsEBatteryEstimatedChargeRemaining OBJECT-TYPE
|
||
|
SYNTAX Integer32 ( 0 .. 100 )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An estimate of the battery charge remaining expressed
|
||
|
as a percent of full charge"
|
||
|
::= { upsEBatterySystem 4 }
|
||
|
|
||
|
upsEPositiveBatteryVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the present positive battery voltage in 0.1 Volt DC"
|
||
|
::= { upsEBatterySystem 5 }
|
||
|
|
||
|
upsENegativeBatteryVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the present negative battery voltage in 0.1 Volt DC"
|
||
|
::= { upsEBatterySystem 6 }
|
||
|
|
||
|
upsEBatteryCellNumber OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "This object indicate the cell number of each set."
|
||
|
::= { upsEBatterySystem 7 }
|
||
|
|
||
|
upsEBatteryTemperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The ambient temperature at or near the UPS Battery
|
||
|
casing in 0.1 degree."
|
||
|
::= { upsEBatterySystem 8 }
|
||
|
|
||
|
upsEBatteryLastReplacedDate OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The date when the Batteries in this UPS were last replaced.
|
||
|
The format should be DD/MM/YYYY."
|
||
|
::= { upsEBatterySystem 9 }
|
||
|
|
||
|
upsEBatteryABMStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { charge ( 1 ) , float ( 2 ) , rest ( 3 ) ,
|
||
|
discharge ( 4 ) , disable ( 5 ) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION " The status of ABM."
|
||
|
::= { upsEBatterySystem 10 }
|
||
|
|
||
|
upsEChargerModulesNum OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger ( 0 .. 32 )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of charger modules inserted to UPS systems. served
|
||
|
as the index of the upsEChargerModulesTable.
|
||
|
The default value 0 indicate that the UPS system don't have
|
||
|
separate charger module."
|
||
|
::= { upsEBatterySystem 11 }
|
||
|
|
||
|
upsEChargerModulesTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsChargerModulesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A list of charger modules entries. The number of entries is given
|
||
|
by the value of upsEchargerModulesNum."
|
||
|
::= { upsEBatterySystem 12 }
|
||
|
|
||
|
upsEChargerModulesEntry OBJECT-TYPE
|
||
|
SYNTAX UpsChargerModulesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular charger module."
|
||
|
INDEX { chargerModulesNum }
|
||
|
::= { upsEChargerModulesTable 1 }
|
||
|
|
||
|
UpsChargerModulesEntry ::= SEQUENCE {
|
||
|
chargerModulesNum PositiveInteger,
|
||
|
chargerModulesAddress NonNegativeInteger ,
|
||
|
positiveChargeVotlage NonNegativeInteger,
|
||
|
negativeChargeVoltage NonNegativeInteger,
|
||
|
positiveChargeCurrent NonNegativeInteger,
|
||
|
negativeChargeCurrent NonNegativeInteger,
|
||
|
chargerModulesTemperature INTEGER,
|
||
|
chargerModulesMode INTEGER
|
||
|
}
|
||
|
|
||
|
|
||
|
chargerModulesNum OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger ( 1 .. 32 )
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of charger modules. Serves as index for charger module table"
|
||
|
::= { upsEChargerModulesEntry 1 }
|
||
|
|
||
|
|
||
|
chargerModulesAddress OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Charger Modules' address."
|
||
|
::= { upsEChargerModulesEntry 2 }
|
||
|
|
||
|
|
||
|
positiveChargeVotlage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured positive charger voltage from the UPS meters in 0.1 volts"
|
||
|
::= { upsEChargerModulesEntry 3 }
|
||
|
|
||
|
|
||
|
negativeChargeVoltage OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured nepositive charger voltage from the UPS meters in 0.1 volts"
|
||
|
::= { upsEChargerModulesEntry 4 }
|
||
|
|
||
|
|
||
|
positiveChargeCurrent OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured positive charger mandatory from the UPS meters in in 0.1 amps."
|
||
|
::= { upsEChargerModulesEntry 5 }
|
||
|
|
||
|
|
||
|
negativeChargeCurrent OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured nepositive charger mandatory from the UPS meters in 0.1 amps."
|
||
|
::= { upsEChargerModulesEntry 6 }
|
||
|
|
||
|
|
||
|
chargerModulesTemperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured charger temperature from the UPS meters in 0.1 degree."
|
||
|
::= { upsEChargerModulesEntry 7 }
|
||
|
|
||
|
|
||
|
chargerModulesMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER { powerOn ( 1 ) , standyby ( 2 ) , fault ( 3 ) , shutdown ( 4 ) ,
|
||
|
running ( 5 ) , suicide ( 6 ) , unknown ( 7 ) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The working mode of charger modules."
|
||
|
::= { upsEChargerModulesEntry 8 }
|
||
|
|
||
|
--========================================================================
|
||
|
--upsEPowerConverterSystem
|
||
|
--========================================================================
|
||
|
|
||
|
upsEUPSModulesNum OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger ( 0 .. 32 )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of UPS modules inserted to UPS systems.
|
||
|
served as the index of the upsEModulesTable.
|
||
|
the default value 0 indicate that the UPS system do not
|
||
|
have separate UPS module."
|
||
|
::= { upsEPowerConverterSystem 1 }
|
||
|
|
||
|
upsEModulesTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsModulesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A list of UPS modules entries. The number of entries is
|
||
|
given by the value of upsEModulesNum."
|
||
|
::= { upsEPowerConverterSystem 2 }
|
||
|
|
||
|
upsEModulesEntry OBJECT-TYPE
|
||
|
SYNTAX UpsModulesEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular upsE module."
|
||
|
INDEX { upsEModulesNum }
|
||
|
::= { upsEModulesTable 1 }
|
||
|
|
||
|
UpsModulesEntry ::= SEQUENCE {
|
||
|
upsEModulesNum PositiveInteger,
|
||
|
upsEModuleAddress INTEGER,
|
||
|
upsEModulePositiveBusVolt NonNegativeInteger,
|
||
|
upsEModuleNegativeBusVolt NonNegativeInteger,
|
||
|
upsEModuleTemperature INTEGER,
|
||
|
upsEModuleWorkingMode INTEGER,
|
||
|
upsEModuleOutputCurrentR NonNegativeInteger,
|
||
|
upsEModuleOutputWattR NonNegativeInteger,
|
||
|
upsEModuleOutputLoadR INTEGER,
|
||
|
upsEModuleWarningCode DisplayString,
|
||
|
upsEModuleFaultCode DisplayString,
|
||
|
|
||
|
upsEModuleTrapState DisplayString,
|
||
|
upsEModuleConfigOutputVA NonNegativeInteger,
|
||
|
upsEModuleOutputCurrentS NonNegativeInteger,
|
||
|
upsEModuleOutputCurrentT NonNegativeInteger,
|
||
|
upsEModuleOutputWattS NonNegativeInteger,
|
||
|
upsEModuleOutputWattT NonNegativeInteger,
|
||
|
upsEModuleOutputLoadS INTEGER,
|
||
|
upsEModuleOutputLoadT INTEGER,
|
||
|
upsEModuleOutputVAR NonNegativeInteger,
|
||
|
upsEModuleOutputVAS NonNegativeInteger,
|
||
|
upsEModuleOutputVAT NonNegativeInteger
|
||
|
}
|
||
|
|
||
|
|
||
|
upsEModulesNum OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger ( 1 .. 32 )
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of UPS modules. Serves as index for UPS module table"
|
||
|
::= { upsEModulesEntry 1 }
|
||
|
|
||
|
|
||
|
upsEModuleAddress OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "the address of UPS modules."
|
||
|
::= { upsEModulesEntry 2 }
|
||
|
|
||
|
|
||
|
upsEModulePositiveBusVolt OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured positive upsE module voltage from the UPS meters in 0.1 volts"
|
||
|
::= { upsEModulesEntry 3 }
|
||
|
|
||
|
|
||
|
upsEModuleNegativeBusVolt OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured nepositive upsE module voltage from the UPS meters in 0.1 volts"
|
||
|
::= { upsEModulesEntry 4 }
|
||
|
|
||
|
|
||
|
upsEModuleTemperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured upsE module temperature from the UPS meters in 0.1 degree."
|
||
|
::= { upsEModulesEntry 5 }
|
||
|
|
||
|
|
||
|
upsEModuleWorkingMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {power-on ( 1 ) , stand-by( 2 ) , by-pass ( 3 ) ,
|
||
|
line( 4 ) , battery ( 5 ) , battery-test ( 6 ) , fault ( 7 ) ,
|
||
|
converter ( 8 ) , eco ( 9 ) , shutdown ( 10 ) , on-booster ( 11 ) , on-reducer ( 12 ) , other( 13 ) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The working mode of UPS modules."
|
||
|
::= { upsEModulesEntry 6 }
|
||
|
|
||
|
|
||
|
upsEModuleOutputCurrentR OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
|
||
|
::= { upsEModulesEntry 7 }
|
||
|
|
||
|
|
||
|
upsEModuleOutputWattR OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
|
||
|
::= { upsEModulesEntry 8 }
|
||
|
|
||
|
|
||
|
upsEModuleOutputLoadR OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The output load of UPS modules in %."
|
||
|
::= { upsEModulesEntry 9 }
|
||
|
|
||
|
upsEModuleWarningCode OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The warning code of ups modules.Please refer the warning table of 'QU,XX' for details."
|
||
|
::= { upsEModulesEntry 10 }
|
||
|
|
||
|
upsEModuleFaultCode OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The fault code of ups modules.Please refer command 'QU,XX' for details."
|
||
|
::= { upsEModulesEntry 11 }
|
||
|
|
||
|
upsEModuleTrapState OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 127 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "the values indicate the unrestored traps.
|
||
|
For example, after AC fail, so the value of upsETrapState should be '1'.
|
||
|
And then the AC restore, the value of upsEModuleTrapState
|
||
|
should change to empty."
|
||
|
::= { upsEModulesEntry 12 }
|
||
|
|
||
|
|
||
|
upsEModuleConfigOutputVA OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
||
|
::= { upsEModulesEntry 13 }
|
||
|
|
||
|
|
||
|
upsEModuleOutputCurrentS OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
|
||
|
::= { upsEModulesEntry 14 }
|
||
|
|
||
|
upsEModuleOutputCurrentT OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
|
||
|
::= { upsEModulesEntry 15 }
|
||
|
|
||
|
upsEModuleOutputWattS OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
|
||
|
::= { upsEModulesEntry 16 }
|
||
|
|
||
|
upsEModuleOutputWattT OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
|
||
|
::= { upsEModulesEntry 17 }
|
||
|
|
||
|
upsEModuleOutputLoadS OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The output load of UPS modules in %."
|
||
|
::= { upsEModulesEntry 18 }
|
||
|
|
||
|
upsEModuleOutputLoadT OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The output load of UPS modules in %."
|
||
|
::= { upsEModulesEntry 19 }
|
||
|
|
||
|
upsEModuleOutputVAR OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
||
|
::= { upsEModulesEntry 20 }
|
||
|
|
||
|
upsEModuleOutputVAS OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
||
|
::= { upsEModulesEntry 21 }
|
||
|
|
||
|
upsEModuleOutputVAT OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
||
|
::= { upsEModulesEntry 22 }
|
||
|
|
||
|
--========================================================================
|
||
|
--upsELoadSegment
|
||
|
--========================================================================
|
||
|
upsELoadSegment1OffDelay OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
|
||
|
Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will
|
||
|
abort the countdown. Read this object will get countdown value of the Load Segment."
|
||
|
::= { upsELoadSegment 1 }
|
||
|
|
||
|
upsELoadSegment1OnDelay OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Setting this object will start the Load segment output after the indicated number of seconds,
|
||
|
including starting the UPS, if necessary. Setting this object to 0 will cause the startup
|
||
|
to occur immediately. Setting this object to -1 will abort the countdown."
|
||
|
::= { upsELoadSegment 2 }
|
||
|
|
||
|
upsELoadSegment1AutoOffTimer OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The load segment turns automatically off after the delay while the unit operates on battery,
|
||
|
but the shutdown is cancelled if the utility return before the delay has expired."
|
||
|
::= { upsELoadSegment 3 }
|
||
|
|
||
|
upsELoadSegment1AutoOnTimer OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The load segment is automatically turned on after a selected delay
|
||
|
if it has been shutdown due to on battery."
|
||
|
::= { upsELoadSegment 4 }
|
||
|
|
||
|
upsELoadSegment1State OBJECT-TYPE
|
||
|
SYNTAX INTEGER { off(1), on(2), off-pending(3), on-pending(4), not-support(5) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Load segment output state."
|
||
|
::= { upsELoadSegment 5 }
|
||
|
|
||
|
upsELoadSegment2OffDelay OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
|
||
|
Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will
|
||
|
abort the countdown. Read this object will get countdown value of the Load Segment."
|
||
|
::= { upsELoadSegment 6 }
|
||
|
|
||
|
upsELoadSegment2OnDelay OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Setting this object will start the Load segment output after the indicated number of seconds,
|
||
|
including starting the UPS, if necessary. Setting this object to 0 will cause the startup
|
||
|
to occur immediately. Setting this object to -1 will abort the countdown."
|
||
|
::= { upsELoadSegment 7 }
|
||
|
|
||
|
upsELoadSegment2AutoOffTimer OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The load segment turns automatically off after the delay while the unit operates on battery,
|
||
|
but the shutdown is cancelled if the utility return before the delay has expired."
|
||
|
::= { upsELoadSegment 8 }
|
||
|
|
||
|
upsELoadSegment2AutoOnTimer OBJECT-TYPE
|
||
|
-- Valid value is from -1 to 32767
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The load segment is automatically turned on after a selected delay
|
||
|
if it has been shutdown due to on battery."
|
||
|
::= { upsELoadSegment 9 }
|
||
|
|
||
|
upsELoadSegment2State OBJECT-TYPE
|
||
|
SYNTAX INTEGER { off(1), on(2), off-pending(3), on-pending(4), not-support(5) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Load segment output state."
|
||
|
::= { upsELoadSegment 10 }
|
||
|
|
||
|
--========================================================================
|
||
|
--upsEEnvironment
|
||
|
--========================================================================
|
||
|
|
||
|
upsEEnvironmentTemperature OBJECT IDENTIFIER ::= { upsEEnvironment 1 }
|
||
|
|
||
|
upsEEnvironmentCurrentTemperature OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measurement of temperature sensor, in 0.1 degree"
|
||
|
::= { upsEEnvironmentTemperature 1 }
|
||
|
|
||
|
upsEEnvironmentTemperatureHighSetPoint OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The set point for high temperature warning, in 0.1 degrees.
|
||
|
This value must be greater than upsEEnvironmentTemperatureLowSetPoint,
|
||
|
and the least significant digit must be zero."
|
||
|
::= { upsEEnvironmentTemperature 2 }
|
||
|
|
||
|
upsEEnvironmentTemperatureHighStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "To enable/disable high set point check with sensor temperature."
|
||
|
::= { upsEEnvironmentTemperature 3 }
|
||
|
|
||
|
upsEEnvironmentTemperatureLowSetPoint OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The set point for low temperature warning, in 0.1 degrees.
|
||
|
This value must be less than upsEEnvironmentTemperatureHighSetPoint,
|
||
|
and the least significant digit must be zero."
|
||
|
::= { upsEEnvironmentTemperature 4 }
|
||
|
|
||
|
upsEEnvironmentTemperatureLowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "To enable/disable low set point check with sensor temperature."
|
||
|
::= { upsEEnvironmentTemperature 5 }
|
||
|
|
||
|
upsEEnvironmentTemperatureOffset OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The offset to calibrate temperature of EMD, in 0.1 degrees"
|
||
|
::= { upsEEnvironmentTemperature 6 }
|
||
|
|
||
|
upsEEnvironmentHumidity OBJECT IDENTIFIER ::= { upsEEnvironment 2 }
|
||
|
|
||
|
upsEEnvironmentCurrentHumidity OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The measurement of sensor humidity present in %."
|
||
|
::= { upsEEnvironmentHumidity 1 }
|
||
|
|
||
|
upsEEnvironmentHumidityHighSetPoint OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The set point for high humidity warning, in %.
|
||
|
This value must be greater than upsEEnvironmentHumidityLowSetPoint."
|
||
|
::= { upsEEnvironmentHumidity 2 }
|
||
|
|
||
|
upsEEnvironmentHumidityHighStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "To enable/disable high set point check with emd humidity."
|
||
|
::= { upsEEnvironmentHumidity 3 }
|
||
|
|
||
|
upsEEnvironmentHumidityLowSetPoint OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The set point for low humidity warning, in %.
|
||
|
This value must be less than upsEEnvironmentHumidityHighSetPoint."
|
||
|
::= { upsEEnvironmentHumidity 4 }
|
||
|
|
||
|
upsEEnvironmentHumidityLowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "To enable/disable high set point check with emd humidity."
|
||
|
::= { upsEEnvironmentHumidity 5 }
|
||
|
|
||
|
upsEEnvironmentHumidityOffset OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The offset to calibrate humidity of EMD, in %."
|
||
|
::= { upsEEnvironmentHumidity 6 }
|
||
|
|
||
|
upsEEnvironmentContactsNum OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of environment contacts, serves as the table index."
|
||
|
::= { upsEEnvironment 3 }
|
||
|
|
||
|
upsEEnvironmentContactTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsEEnvironmentContactEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "A list of contacts table entries. The number of entries is given by the
|
||
|
value of upsEEnvironmentContactsNum"
|
||
|
::= { upsEEnvironment 4 }
|
||
|
|
||
|
upsEEnvironmentContactEntry OBJECT-TYPE
|
||
|
SYNTAX UpsEEnvironmentContactEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular contact"
|
||
|
INDEX { upsEEnvironmentContactIndex }
|
||
|
::= { upsEEnvironmentContactTable 1 }
|
||
|
|
||
|
UpsEEnvironmentContactEntry ::= SEQUENCE {
|
||
|
upsEEnvironmentContactIndex PositiveInteger,
|
||
|
upsEEnvironmentContactType INTEGER,
|
||
|
upsEEnvironmentContactState INTEGER,
|
||
|
upsEEnvironmentContactDescription DisplayString
|
||
|
}
|
||
|
|
||
|
|
||
|
upsEEnvironmentContactIndex OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The number of environment contacts. Serves as index for environment contact table"
|
||
|
::= { upsEEnvironmentContactEntry 1 }
|
||
|
|
||
|
|
||
|
upsEEnvironmentContactType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { normallyOpen ( 1 ) , normallyClosed ( 2 ) , notUsed ( 3 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "operation type"
|
||
|
::= { upsEEnvironmentContactEntry 2 }
|
||
|
|
||
|
|
||
|
upsEEnvironmentContactState OBJECT-TYPE
|
||
|
SYNTAX INTEGER { open ( 1 ) , closed ( 2 ) , openWithNotice ( 3 ) , closedWithNotice ( 4 ) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The mandatory status."
|
||
|
::= { upsEEnvironmentContactEntry 3 }
|
||
|
|
||
|
|
||
|
upsEEnvironmentContactDescription OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of environment contact."
|
||
|
::= { upsEEnvironmentContactEntry 4 }
|
||
|
|
||
|
--========================================================================
|
||
|
--upsEBatteryTest
|
||
|
--========================================================================
|
||
|
|
||
|
upsEBatteryTestStart OBJECT-TYPE
|
||
|
SYNTAX INTEGER { none ( 1 ) , batteryTest10Sec ( 2 ) , batteryTestUntilLow ( 3 ) ,
|
||
|
batteryTestWithTime ( 4 ) , cancelBatteryTest ( 5 ) , clearBatteryInfo ( 6 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "This object specify the battery test type and initiate battery test.
|
||
|
If battTestWithTime selected, the test time is refer to upsEBatteryTestSettingTime."
|
||
|
::= { upsEBatteryTest 1 }
|
||
|
|
||
|
upsEBatteryTestSettingTime OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The object specify the test time for battery test in seconds."
|
||
|
::= { upsEBatteryTest 2 }
|
||
|
|
||
|
upsEBatteryTestResult OBJECT-TYPE
|
||
|
SYNTAX INTEGER { idle ( 1 ) , processing ( 2 ) , noFailure ( 3 ) ,
|
||
|
failureOrWarning ( 4 ) , notPossible ( 5 ) , testCancel ( 6 ) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "This object indicate the test result of battery."
|
||
|
::= { upsEBatteryTest 3 }
|
||
|
|
||
|
upsEBatteryTestStartTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 19 .. 19 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The value of the time the test in progress was initiated,
|
||
|
or, if no test is in progress, the time the previous test
|
||
|
was initiated. If the value of upsETestBatteryTestResult
|
||
|
is noTestsInitiated(6), upsETestStartTime has the value
|
||
|
01/01/1970 00:00:00."
|
||
|
::= { upsEBatteryTest 4 }
|
||
|
|
||
|
upsEBatteryTestElapsedTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 11 .. 11 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The amount of time in format hh:mm:ss, since the test in progress
|
||
|
was initiated, or, if no test is in progress, the previous
|
||
|
test took to complete. If the value of upsTestResultsSummary
|
||
|
is idle(1), upsTestElapsedTime has the value 00:00:00."
|
||
|
::= { upsEBatteryTest 5 }
|
||
|
|
||
|
|
||
|
upsEBatteryTestScheduleTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsBatteryTestScheduleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "This table describes the schedule for automatically battery
|
||
|
test."
|
||
|
::= { upsEBatteryTest 6 }
|
||
|
|
||
|
upsEBatteryTestScheduleEntry OBJECT-TYPE
|
||
|
SYNTAX UpsBatteryTestScheduleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to schedule test."
|
||
|
INDEX { upsEBatteryTestScheduleIndex }
|
||
|
::= { upsEBatteryTestScheduleTable 1 }
|
||
|
|
||
|
UpsBatteryTestScheduleEntry ::= SEQUENCE {
|
||
|
upsEBatteryTestScheduleIndex PositiveInteger,
|
||
|
upsEBatteryTestScheduleDay INTEGER,
|
||
|
upsEBatteryTestScheduleTime DisplayString,
|
||
|
upsEBatteryTestScheduleType INTEGER,
|
||
|
upsEBatteryTestScheduleTestWithTime NonNegativeInteger,
|
||
|
upsEBatteryTestScheduleSpecialDay DisplayString
|
||
|
}
|
||
|
|
||
|
|
||
|
upsEBatteryTestScheduleIndex OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The index of battery test scheduled."
|
||
|
::= { upsEBatteryTestScheduleEntry 1 }
|
||
|
|
||
|
|
||
|
upsEBatteryTestScheduleDay OBJECT-TYPE
|
||
|
SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednsday ( 3 ) ,
|
||
|
thusday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
|
||
|
sunday ( 7 ) , specialday ( 8 ) , none ( 9 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The weekday or specaial day on which the UPS should start battery test."
|
||
|
::= { upsEBatteryTestScheduleEntry 2 }
|
||
|
|
||
|
|
||
|
upsEBatteryTestScheduleTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 5 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The time that the battery test will be initiated in hh:mm format."
|
||
|
::= { upsEBatteryTestScheduleEntry 3 }
|
||
|
|
||
|
|
||
|
upsEBatteryTestScheduleType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { none ( 1 ) , batteryTest10sec ( 2 ) , batteryTestUntilLow ( 3 ) ,
|
||
|
batteryTestWithTime ( 4 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The type of battery test."
|
||
|
::= { upsEBatteryTestScheduleEntry 5 }
|
||
|
|
||
|
|
||
|
upsEBatteryTestScheduleTestWithTime OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The battery time of setting time test in seconds."
|
||
|
::= { upsEBatteryTestScheduleEntry 6 }
|
||
|
|
||
|
|
||
|
upsEBatteryTestScheduleSpecialDay OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 10 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The special day that the battery test will be initiated in dd/mm/yyyy format."
|
||
|
::= { upsEBatteryTestScheduleEntry 7 }
|
||
|
|
||
|
--========================================================================
|
||
|
-- upsEControl
|
||
|
--========================================================================
|
||
|
|
||
|
upsEControlOutputOffDelay OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Setting this value to other than zero will cause the UPS
|
||
|
output to turn off after the number of seconds. "
|
||
|
::= { upsEControl 1 }
|
||
|
|
||
|
upsEControlOutputOnDelay OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Setting this value to other than zero will cause the
|
||
|
UPS output to turn on after the number of seconds. "
|
||
|
::= { upsEControl 2 }
|
||
|
|
||
|
upsEControlOutputOnOffControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER { upsEOutputOff ( 1 ) , upsEOutputOffCancel ( 2 ) , upsESleep( 3 ) , none ( 4 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "upsEOutputOff ( 1 ) indicates the shutdown sequence,
|
||
|
upsEOutputOffCancel ( 2 ) indicates cancel the shutdown sequence,
|
||
|
upsESleep( 3 ) indicates shutdown UPS first, then switch on."
|
||
|
::= { upsEControl 3 }
|
||
|
|
||
|
upsEShutdownEventsTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsShutdownEventsEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "This table describes the parametes for shutdown process
|
||
|
when shutdown event occurs"
|
||
|
::= { upsEControl 4 }
|
||
|
|
||
|
upsEShutdownEventsEntry OBJECT-TYPE
|
||
|
SYNTAX UpsShutdownEventsEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular shutdown
|
||
|
event line"
|
||
|
INDEX { upsEShutdownEvent }
|
||
|
::= { upsEShutdownEventsTable 1 }
|
||
|
|
||
|
UpsShutdownEventsEntry ::= SEQUENCE {
|
||
|
upsEShutdownEvent INTEGER,
|
||
|
upsEShutdownEventAction INTEGER,
|
||
|
upsEShutdownwarningPeriodTime NonNegativeInteger,
|
||
|
upsEShutdownWarningPeriodInterval NonNegativeInteger
|
||
|
}
|
||
|
|
||
|
|
||
|
upsEShutdownEvent OBJECT-TYPE
|
||
|
SYNTAX INTEGER { acFail ( 1 ) , batteryLow ( 2 ) , upsEOverLoad ( 3 ) ,
|
||
|
upsEOverTemperature ( 4 ) , upsEWeeklySchedule ( 5 ) ,
|
||
|
upsESpecialSchedule ( 6 ) , environmentTemperatureOverThreshold ( 7 ) ,
|
||
|
environmentHumidityOverThreshold ( 8 ) , environmentContact1Alarm ( 9 ) ,
|
||
|
environmentContact2Alarm ( 10 ), belowCapacityLimit( 11 ), belowRemainTimeLimit( 12 )}
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The shutdown event identification"
|
||
|
::= { upsEShutdownEventsEntry 1 }
|
||
|
|
||
|
|
||
|
upsEShutdownEventAction OBJECT-TYPE
|
||
|
SYNTAX INTEGER { disable ( 1 ) , warning ( 2 ) , shutdownClient ( 3 ) , shutdownUPS ( 4 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Status of the corresponding shutdown Event.
|
||
|
When set to disable(), shutdown process will not start when
|
||
|
corresponding event occured."
|
||
|
::= { upsEShutdownEventsEntry 2 }
|
||
|
|
||
|
|
||
|
upsEShutdownwarningPeriodTime OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The Delay in seconds after the occurance of the curresponding shutdown
|
||
|
event, and warning message should be popped in this period."
|
||
|
::= { upsEShutdownEventsEntry 3 }
|
||
|
|
||
|
|
||
|
upsEShutdownWarningPeriodInterval OBJECT-TYPE
|
||
|
SYNTAX NonNegativeInteger
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The frequency of sending warning messages to the connected
|
||
|
clients when the curresponding shutdown event occurs.
|
||
|
The value is in units of seconds."
|
||
|
::= { upsEShutdownEventsEntry 4 }
|
||
|
|
||
|
upsEControlWeeklyScheduleTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsControlWeeklyScheduleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The table to schedule shutting down the ups by weekly"
|
||
|
::= { upsEControl 5 }
|
||
|
|
||
|
upsEControlWeeklyScheduleEntry OBJECT-TYPE
|
||
|
SYNTAX UpsControlWeeklyScheduleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular line"
|
||
|
INDEX { upsEControlWeeklyScheduleIndex }
|
||
|
::= { upsEControlWeeklyScheduleTable 1 }
|
||
|
|
||
|
UpsControlWeeklyScheduleEntry ::= SEQUENCE {
|
||
|
upsEControlWeeklyScheduleIndex PositiveInteger,
|
||
|
upsEWeeklyScheduleShutdownDay INTEGER,
|
||
|
upsEWeeklyScheduleShutdownTime DisplayString,
|
||
|
upsEWeeklyScheduleRestartDay INTEGER,
|
||
|
upsEWeeklyScheduleRestartTime DisplayString
|
||
|
}
|
||
|
|
||
|
|
||
|
upsEControlWeeklyScheduleIndex OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "the index of schedule events."
|
||
|
::= { upsEControlWeeklyScheduleEntry 1 }
|
||
|
|
||
|
|
||
|
upsEWeeklyScheduleShutdownDay OBJECT-TYPE
|
||
|
SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednesday ( 3 ) ,
|
||
|
thursday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
|
||
|
sunday ( 7 ) , none ( 8 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "the weekday on which upsE shoud shutdown"
|
||
|
::= { upsEControlWeeklyScheduleEntry 2 }
|
||
|
|
||
|
|
||
|
upsEWeeklyScheduleShutdownTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 5 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The time that the process of shutting down the UPS will be initiated
|
||
|
in hh:mm format."
|
||
|
::= { upsEControlWeeklyScheduleEntry 3 }
|
||
|
|
||
|
|
||
|
upsEWeeklyScheduleRestartDay OBJECT-TYPE
|
||
|
SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednesday ( 3 ) ,
|
||
|
thursday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
|
||
|
sunday ( 7 ) , none ( 8 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "the weekday on which the UPS should restart."
|
||
|
::= { upsEControlWeeklyScheduleEntry 4 }
|
||
|
|
||
|
|
||
|
upsEWeeklyScheduleRestartTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The time the UPS will restart in hh:mm format."
|
||
|
::= { upsEControlWeeklyScheduleEntry 5 }
|
||
|
|
||
|
upsEControlSpecialDayScheduleTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsControlSpecialDayScheduleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The table to schedule shutting down the ups."
|
||
|
::= { upsEControl 6 }
|
||
|
|
||
|
upsEControlSpecialDayScheduleEntry OBJECT-TYPE
|
||
|
SYNTAX UpsControlSpecialDayScheduleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular line."
|
||
|
INDEX { upsEControlSpecialDayScheduleIndex }
|
||
|
::= { upsEControlSpecialDayScheduleTable 1 }
|
||
|
|
||
|
UpsControlSpecialDayScheduleEntry ::= SEQUENCE {
|
||
|
upsEControlSpecialDayScheduleIndex PositiveInteger,
|
||
|
upsESpecialDayScheduleShutdownDay DisplayString,
|
||
|
upsESpecialDayScheduleShutdownTime DisplayString,
|
||
|
upsESpecialDayScheduleRestartDay DisplayString,
|
||
|
upsESpecialDayScheduleRestartTime DisplayString
|
||
|
}
|
||
|
|
||
|
|
||
|
upsEControlSpecialDayScheduleIndex OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The index of special day schedule."
|
||
|
::= { upsEControlSpecialDayScheduleEntry 1 }
|
||
|
|
||
|
|
||
|
upsESpecialDayScheduleShutdownDay OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The special day on which UPS should shutdown with the format
|
||
|
of DD/MM/YYYY."
|
||
|
::= { upsEControlSpecialDayScheduleEntry 2 }
|
||
|
|
||
|
|
||
|
upsESpecialDayScheduleShutdownTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The time that the process of shutting down the UPS will be initiated
|
||
|
in hh:mm format."
|
||
|
::= { upsEControlSpecialDayScheduleEntry 3 }
|
||
|
|
||
|
|
||
|
upsESpecialDayScheduleRestartDay OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The special day on which the UPS should restart with the format
|
||
|
of DD/MM/YYYY."
|
||
|
::= { upsEControlSpecialDayScheduleEntry 4 }
|
||
|
|
||
|
|
||
|
upsESpecialDayScheduleRestartTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The time the UPS will restart in hh:mm format."
|
||
|
::= { upsEControlSpecialDayScheduleEntry 5 }
|
||
|
|
||
|
upsESystemMasterOffDelay OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The UPS output will shutdown after the indicated number of seconds, -1 indicate no action."
|
||
|
::= { upsEControl 7 }
|
||
|
upsESystemMasterOnDelay OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The UPS output will start on after the indicated number of seconds, -1 indicate no action."
|
||
|
::= { upsEControl 8 }
|
||
|
|
||
|
--========================================================================
|
||
|
-- upsETrapControl
|
||
|
--========================================================================
|
||
|
|
||
|
upsETrapsReceiversTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF UpsTrapsReceiversEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION " This table list the managers'IP to send traps to."
|
||
|
::= { upsETrapControl 1 }
|
||
|
|
||
|
upsETrapsReceiversEntry OBJECT-TYPE
|
||
|
SYNTAX UpsTrapsReceiversEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "An entry containing information applicable to a particular input line."
|
||
|
INDEX { upsETrapsReceiversIndex }
|
||
|
::= { upsETrapsReceiversTable 1 }
|
||
|
|
||
|
UpsTrapsReceiversEntry ::= SEQUENCE {
|
||
|
upsETrapsReceiversIndex PositiveInteger,
|
||
|
upsETrapsReceiverAddress DisplayString,
|
||
|
upsETrapReceiverCommunityString DisplayString,
|
||
|
upsETrapType INTEGER,
|
||
|
upsETrapsSeverityLevel INTEGER,
|
||
|
upsETrapReceiverDescription DisplayString
|
||
|
}
|
||
|
|
||
|
upsETrapsReceiversIndex OBJECT-TYPE
|
||
|
SYNTAX PositiveInteger
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The index to a trap receiver entry"
|
||
|
::= { upsETrapsReceiversEntry 1 }
|
||
|
|
||
|
upsETrapsReceiverAddress OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 45 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The IP address of the manager to send a trap to."
|
||
|
::= { upsETrapsReceiversEntry 2 }
|
||
|
|
||
|
upsETrapReceiverCommunityString OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The community name to use in the trap when
|
||
|
sent to the manager."
|
||
|
::= { upsETrapsReceiversEntry 3 }
|
||
|
|
||
|
upsETrapType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { none ( 1 ) , rfc1628Trap ( 2 ) , eppcTrap ( 3 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The type of trap to be received by the manager."
|
||
|
::= { upsETrapsReceiversEntry 4 }
|
||
|
|
||
|
upsETrapsSeverityLevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER { informational ( 1 ) , warning ( 2 ) , severe ( 3 ) }
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The severity level of traps to be received by this manager."
|
||
|
::= { upsETrapsReceiversEntry 5 }
|
||
|
|
||
|
upsETrapReceiverDescription OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "Description of trap receivers"
|
||
|
::= { upsETrapsReceiversEntry 6 }
|
||
|
|
||
|
upsETrapState OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 127 ) )
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "the values indicate the unrestored traps.
|
||
|
For example, after AC fail, the agent send
|
||
|
the trap 1(AC Fail) and trap 7(battery on) to
|
||
|
NMS. so the value of upsETrapState should be '1,7'.
|
||
|
And then the AC restore, the value of upsETrapState
|
||
|
should change to empty."
|
||
|
::= { upsETrapControl 2 }
|
||
|
|
||
|
-- ===========================================================================
|
||
|
-- Trap defination
|
||
|
-- ===========================================================================
|
||
|
|
||
|
upsEPowerFail TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Utility power not available."
|
||
|
::= 1
|
||
|
|
||
|
upsEPowerRestored TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Utility power has restored."
|
||
|
::= 2
|
||
|
|
||
|
upsELowBattery TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"SEVERE: The UPS batteries are low and will soon be exhausted."
|
||
|
::= 3
|
||
|
|
||
|
upsEReturnFromLowBattery TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS has return from a low battery condition."
|
||
|
::= 4
|
||
|
|
||
|
upsEFailed TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"SEVERE: The UPS is not working fine."
|
||
|
::= 5
|
||
|
|
||
|
upsEOk TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS is working fine."
|
||
|
::= 6
|
||
|
|
||
|
upsEOnBattery TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEBatteryEstimatedMinutesRemaining,
|
||
|
upsESecondsOnBattery
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: The UPS has switched to battery backup power."
|
||
|
::= 7
|
||
|
|
||
|
upsENotOnBattery TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS is not on battery power."
|
||
|
::= 8
|
||
|
|
||
|
upsETestInProgress TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The testing is going on ups."
|
||
|
::= 9
|
||
|
|
||
|
upsETestOver TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEBatteryTestStart,
|
||
|
upsEBatteryTestSettingTime,
|
||
|
upsEBatteryTestResult,
|
||
|
upsEBatteryTestStartTime
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The testing of UPS is completed."
|
||
|
::= 10
|
||
|
|
||
|
upsEBypassOn TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS has enabled bypass."
|
||
|
::= 11
|
||
|
|
||
|
upsEOnline TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS is not on Bypass and return to normal status."
|
||
|
::= 12
|
||
|
|
||
|
upsECommunicationLost TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"SEVERE: Communication to the UPS has been lost."
|
||
|
::= 13
|
||
|
|
||
|
upsECommunicationEstablished TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Communication with the UPS has been established."
|
||
|
::= 14
|
||
|
|
||
|
upsEGoingShutdown TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: The UPS is going to shutdown output."
|
||
|
::= 15
|
||
|
|
||
|
upsEShutdownCancelled TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS is not going to shutdown output."
|
||
|
::= 16
|
||
|
|
||
|
upsEOutlet1GoingShutdown TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: The UPS is going to shutdown outlet1."
|
||
|
::= 17
|
||
|
|
||
|
upsEOutlet1ShutdownCancelled TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS is not going to shutdown outlet1."
|
||
|
::= 18
|
||
|
|
||
|
upsEOutlet2GoingShutdown TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: The UPS is going to shutdown outlet2."
|
||
|
::= 19
|
||
|
|
||
|
upsEOutlet2ShutdownCancelled TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS is not going to shutdown outlet2."
|
||
|
::= 20
|
||
|
|
||
|
upsESleeping TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEControlOutputOnDelay
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: UPS has entered sleep mode and power to load has been cut off."
|
||
|
::= 21
|
||
|
|
||
|
upsEWokeUp TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS woke up from sleep mode and power to load has been restored."
|
||
|
::= 22
|
||
|
|
||
|
upsEOverTemperature TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsESystemTemperature,
|
||
|
upsESystemConfigOverTemperatureSetPoint
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: The UPS temperature is over the setting limit."
|
||
|
::= 23
|
||
|
|
||
|
upsENotOverTemperature TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsESystemTemperature,
|
||
|
upsESystemConfigOverTemperatureSetPoint
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS temperature is not over the setting limit."
|
||
|
::= 24
|
||
|
|
||
|
upsEOverLoad TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsESystemOutputLoad,
|
||
|
upsESystemConfigOutputLoadHighSetPoint
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: The UPS load is over the setting limit."
|
||
|
::= 25
|
||
|
|
||
|
upsENotOverLoad TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsESystemOutputLoad,
|
||
|
upsESystemConfigOutputLoadHighSetPoint
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS load is not over the setting limit."
|
||
|
::= 26
|
||
|
|
||
|
upsEModuleInserted TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: UPS module or charger module plug-in."
|
||
|
::= 27
|
||
|
|
||
|
upsEModuleRemoved TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: UPS module or charger module unplugs."
|
||
|
::= 28
|
||
|
|
||
|
sensorTemperatureTooHigh TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentTemperatureHighSetPoint,
|
||
|
upsEEnvironmentCurrentTemperature
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: Sensor Temperature over high Set point."
|
||
|
::= 29
|
||
|
|
||
|
sensorTemperatureNotHigh TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentTemperatureHighSetPoint,
|
||
|
upsEEnvironmentCurrentTemperature
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Sensor Temperature not over high Set point."
|
||
|
::= 30
|
||
|
|
||
|
sensorTemperatureTooLow TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentTemperatureLowSetPoint,
|
||
|
upsEEnvironmentCurrentTemperature
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: Sensor Temperature under low Set point."
|
||
|
::= 31
|
||
|
|
||
|
sensorTemperatureNotLow TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentTemperatureLowSetPoint,
|
||
|
upsEEnvironmentCurrentTemperature
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Sensor Temperature not under low Set point."
|
||
|
::= 32
|
||
|
|
||
|
sensorHumidityTooHigh TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentHumidityHighSetPoint,
|
||
|
upsEEnvironmentCurrentHumidity
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: Sensor Humidity over high Set point."
|
||
|
::= 33
|
||
|
|
||
|
sensorHumidityNotHigh TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentHumidityHighSetPoint,
|
||
|
upsEEnvironmentCurrentHumidity
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Sensor Humidity not over high Set point."
|
||
|
::= 34
|
||
|
|
||
|
sensorHumidityTooLow TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentHumidityLowSetPoint,
|
||
|
upsEEnvironmentCurrentHumidity
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: Sensor Humidity under low Set point."
|
||
|
::= 35
|
||
|
|
||
|
sensorHumidityNotLow TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentHumidityLowSetPoint,
|
||
|
upsEEnvironmentCurrentHumidity
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Sensor Humidity not under low Set point."
|
||
|
::= 36
|
||
|
|
||
|
contactAlarm1Active TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentContactType,
|
||
|
upsEEnvironmentContactDescription
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: Contact Alarm-1 activated."
|
||
|
::= 37
|
||
|
|
||
|
concactAlarm1Normal TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentContactType,
|
||
|
upsEEnvironmentContactDescription
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Contact Alarm-1 not active."
|
||
|
::= 38
|
||
|
|
||
|
contactAlarm2Active TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentContactType,
|
||
|
upsEEnvironmentContactDescription
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"WARNING: Contact Alarm-2 activated."
|
||
|
::= 39
|
||
|
|
||
|
contactAlarm2Normal TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEEnvironmentContactType,
|
||
|
upsEEnvironmentContactDescription
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Contact Alarm-2 not active."
|
||
|
::= 40
|
||
|
|
||
|
upsEInternalwarning TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Internal warning."
|
||
|
::= 41
|
||
|
|
||
|
upsEReturnFromInternalwarning TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Internal warning."
|
||
|
::= 42
|
||
|
|
||
|
upsEEPOActive TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: EPO Active."
|
||
|
::= 43
|
||
|
|
||
|
upsEReturnFromEPOActive TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from EPO Active."
|
||
|
::= 44
|
||
|
|
||
|
upsEModuleUnlock TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Module Unlock."
|
||
|
::= 45
|
||
|
|
||
|
upsEReturnFromModuleUnlock TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Module Unlock."
|
||
|
::= 46
|
||
|
|
||
|
upsEMain1Neutralloss TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Main 1 Neutral loss."
|
||
|
::= 47
|
||
|
|
||
|
upsEReturnFromMain1Neutralloss TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Main 1 Neutral loss."
|
||
|
::= 48
|
||
|
|
||
|
upsEMain1phaseerror TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Main 1 phase error."
|
||
|
::= 49
|
||
|
|
||
|
upsEReturnFromMain1phaseerror TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Main 1 phase error."
|
||
|
::= 50
|
||
|
|
||
|
upsESitefault TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Site fault."
|
||
|
::= 51
|
||
|
|
||
|
upsEReturnFromSitefault TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Site fault."
|
||
|
::= 52
|
||
|
|
||
|
upsEBypassAbnormal TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Bypass Abnormal."
|
||
|
::= 53
|
||
|
|
||
|
upsEReturnFromBypassAbnormal TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Bypass Abnormal."
|
||
|
::= 54
|
||
|
|
||
|
upsEBypassPhaseError TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Bypass Phase Error."
|
||
|
::= 55
|
||
|
|
||
|
upsEReturnFromBypassPhaseError TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Bypass Phase Error."
|
||
|
::= 56
|
||
|
|
||
|
upsEBatteryOpen TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Battery Open."
|
||
|
::= 57
|
||
|
|
||
|
upsEReturnFromBatteryOpen TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Battery Open."
|
||
|
::= 58
|
||
|
|
||
|
upsEBatteryOverCharge TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Battery Over Charge."
|
||
|
::= 59
|
||
|
|
||
|
upsEReturnFromBatteryOverCharge TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Battery Over Charge."
|
||
|
::= 60
|
||
|
|
||
|
upsEBatteryReverse TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Battery Reverse."
|
||
|
::= 61
|
||
|
|
||
|
upsEReturnFromBatteryReverse TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Battery Reverse."
|
||
|
::= 62
|
||
|
|
||
|
upsEOverloadforewarning TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Overload forewarning."
|
||
|
::= 63
|
||
|
|
||
|
upsEReturnFromOverloadforewarning TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Overload forewarning."
|
||
|
::= 64
|
||
|
|
||
|
upsEOverloadWarning TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Overload Warning."
|
||
|
::= 65
|
||
|
|
||
|
upsEReturnFromOverloadWarning TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Overload Warning."
|
||
|
::= 66
|
||
|
|
||
|
upsEFanLock TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Fan Lock."
|
||
|
::= 67
|
||
|
|
||
|
upsEReturnFromFanLock TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Fan Lock."
|
||
|
::= 68
|
||
|
|
||
|
upsEMaintaincoverisopen TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Maintain cover is open."
|
||
|
::= 69
|
||
|
|
||
|
upsEReturnFromMaintaincoverisopen TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Maintain cover is open."
|
||
|
::= 70
|
||
|
|
||
|
upsEChargerfault TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Charger fault."
|
||
|
::= 71
|
||
|
|
||
|
upsEReturnFromChargerfault TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Charger fault."
|
||
|
::= 72
|
||
|
|
||
|
upsEModulelocationerror TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Module location error."
|
||
|
::= 73
|
||
|
|
||
|
upsEReturnFromModulelocationerror TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Module location error."
|
||
|
::= 74
|
||
|
|
||
|
upsETurnonabnormal TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Turn on abnormal."
|
||
|
::= 75
|
||
|
|
||
|
upsEReturnFromTurnonabnormal TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Turn on abnormal."
|
||
|
::= 76
|
||
|
|
||
|
upsERedundancyloss TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Redundancy loss."
|
||
|
::= 77
|
||
|
|
||
|
upsEReturnFromRedundancyloss TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Redundancy loss."
|
||
|
::= 78
|
||
|
|
||
|
upsEHotSwapActived TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Hot Swap Active."
|
||
|
::= 79
|
||
|
|
||
|
upsEReturnFromHotSwapActived TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Hot Swap Active."
|
||
|
::= 80
|
||
|
|
||
|
upsEBatteryInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Battery Inform."
|
||
|
::= 81
|
||
|
|
||
|
upsEReturnFromBatteryInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Battery Inform."
|
||
|
::= 82
|
||
|
|
||
|
upsEInspectionInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Inspection Inform."
|
||
|
::= 83
|
||
|
|
||
|
upsEReturnFromInspectionInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Inspection Inform."
|
||
|
::= 84
|
||
|
|
||
|
upsEGuaranteeInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Guarantee Inform."
|
||
|
::= 85
|
||
|
|
||
|
upsEReturnFromGuaranteeInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Guarantee Inform."
|
||
|
::= 86
|
||
|
|
||
|
upsETemperatureLow TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Temperature Low."
|
||
|
::= 87
|
||
|
|
||
|
upsEReturnFromTemperatureLow TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Temperature Low."
|
||
|
::= 88
|
||
|
|
||
|
upsETemperatureHigh TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Temperature High."
|
||
|
::= 89
|
||
|
|
||
|
upsEReturnFromTemperatureHigh TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Temperature High."
|
||
|
::= 90
|
||
|
|
||
|
upsEBatteryOverTemperature TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Battery Over Temperature."
|
||
|
::= 91
|
||
|
|
||
|
upsEReturnFromBatteryOverTemperature TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Battery Over Temperature."
|
||
|
::= 92
|
||
|
|
||
|
upsEFanMaintainInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Fan Maintain Inform."
|
||
|
::= 93
|
||
|
|
||
|
upsEReturnFromFanMaintainInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Fan Maintain Inform."
|
||
|
::= 94
|
||
|
|
||
|
upsEBusCapacitanceMaintainInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Bus Capacitance Maintain Inform."
|
||
|
::= 95
|
||
|
|
||
|
upsEReturnFromBusCapacitanceMaintainInform TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from Bus Capacitance Maintain Inform."
|
||
|
::= 96
|
||
|
|
||
|
upsESystemOverCapacity TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: System Over Capacity."
|
||
|
::= 97
|
||
|
|
||
|
upsEReturnFromSystemOverCapacity TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Return from System Over Capacity."
|
||
|
::= 98
|
||
|
|
||
|
-- Trap Id 99-122 is not defined.
|
||
|
|
||
|
upsEBelowCapacityLimit TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEBatteryEstimatedChargeRemaining,
|
||
|
upsESystemConfigBelowCapacityLimit
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"SEVERE: The UPS batteries capacity is lower than setting limit."
|
||
|
::= 123
|
||
|
|
||
|
upsENotBelowCapacityLimit TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS batteries capacity is not lower than setting limit."
|
||
|
::= 124
|
||
|
|
||
|
upsEBelowRemainTimeLimit TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
VARIABLES {
|
||
|
upsEBatteryEstimatedMinutesRemaining,
|
||
|
upsESystemConfigBelowRemainTimeLimit
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"SEVERE: The UPS batteries backup time is below the setting limit."
|
||
|
::= 125
|
||
|
|
||
|
upsENotBelowRemainTimeLimit TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: The UPS batteries backup time is not below the setting limit."
|
||
|
::= 126
|
||
|
|
||
|
upsELoadSegment1Off TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Load segment 1 is off."
|
||
|
::= 127
|
||
|
upsELoadSegment1On TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Load segment 1 is on."
|
||
|
::= 128
|
||
|
|
||
|
upsELoadSegment2Off TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"WARNING: Load segment 2 is off."
|
||
|
::= 129
|
||
|
upsELoadSegment2On TRAP-TYPE
|
||
|
ENTERPRISE upsETraps
|
||
|
DESCRIPTION
|
||
|
"INFORMATION: Load segment 2 is on."
|
||
|
::= 130
|
||
|
|
||
|
END
|
||
|
|