mibs/MIBS/raisecom/RAISECOM-FANMONITOR-MIB

293 lines
11 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- MibName=raisecomSynce
-- *****************************************************************
-- Version 1.0 Created 2010.12.30 by hongding
-- This version of MIB is created just for the Management of fan .
--
-- Copyright(c) 2002-2012 by RAISECOM TECH, Ltd.
-- All rights reserved.
--
-- modify history
-- 01,20120418,yangzhonghong, ITS00020700,change the enum values of the raisecomFanCardState node
-- 01,20121206,guokai, ESW00006977,add raisecomFanMonitorTrapSendEnable
-- *****************************************************************
RAISECOM-FANMONITOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
raisecomSystem
FROM RAISECOM-SYSTEM-MIB
TruthValue
FROM SNMPv2-TC
Integer32,Unsigned32,Counter32
FROM SNMPv2-SMI;
raisecomFanMonitor MODULE-IDENTITY
LAST-UPDATED "201012270000Z"
ORGANIZATION "Raisecom, Inc."
CONTACT-INFO
" Raise Systems
Postal: Beijing,
China
Tel: 86-010-82884499
E-mail: support@raisecom.com"
DESCRIPTION
"Configuration of fanMonitor object."
-- -------------------------------------------------------------
-- modify history
-- -------------------------------------------------------------
REVISION "201012300000Z"
DESCRIPTION "The initial revision of this MIB."
::= { raisecomSystem 5}
-- -------------------------------------------------------------
-- groups in the raisecomFanMonitor MIB
-- -------------------------------------------------------------
raisecomFanMonitorNotification OBJECT IDENTIFIER ::= { raisecomFanMonitor 1 }
raisecomFanMonitorMibObjects OBJECT IDENTIFIER ::= { raisecomFanMonitor 2 }
-- -------------------------------------------------------------
-- raisecomFanMonitorNotification
-- -------------------------------------------------------------
raisecomFanSpeedNormal NOTIFICATION-TYPE
OBJECTS { raisecomFanIndex,
raisecomFanSpeedValue
}
STATUS current
DESCRIPTION
"The trap notification occur when fan state translating from abnormal to normal."
::= { raisecomFanMonitorNotification 1 }
raisecomFanSpeedAbnormal NOTIFICATION-TYPE
OBJECTS { raisecomFanIndex,
raisecomFanSpeedValue,
raisecomFanSpeedDueValue
}
STATUS current
DESCRIPTION
"The trap notification occur when fan state translatingfrom normal to abnormal."
::= { raisecomFanMonitorNotification 2 }
raisecomFanCardUp NOTIFICATION-TYPE
OBJECTS { raisecomFanCardState }
STATUS current
DESCRIPTION
"The trap notification occur when fan card state translating from down to up."
::= { raisecomFanMonitorNotification 3 }
raisecomFanCardDown NOTIFICATION-TYPE
OBJECTS { raisecomFanCardState }
STATUS current
DESCRIPTION
"The trap notification occur when fan card state translating from up to down."
::= { raisecomFanMonitorNotification 4 }
-- -------------------------------------------------------------
-- raisecomFanMonitorMibObjects
-- -------------------------------------------------------------
raisecomFanMonitorGlobalGroup OBJECT IDENTIFIER ::= { raisecomFanMonitorMibObjects 1 }
-- -------------------------------------------------------------
-- raisecomFanMonitorGlobalGroup
-- -------------------------------------------------------------
raisecomFanMonitorMode OBJECT-TYPE
SYNTAX INTEGER
{
enforce(1),
auto(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An integer value that specify the current monitor mode.
ENFORCE(1) means that the fan speed need to set manully;
AUTO(2) means that the fan speed will ajusted autoly according
to the temperature"
::= { raisecomFanMonitorGlobalGroup 1 }
raisecomFanMonitorSpdLevel OBJECT-TYPE
SYNTAX Unsigned32(1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the speed level of fan in enforce mode."
::= { raisecomFanMonitorGlobalGroup 2 }
raisecomFanMonitorNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the number of fan being monitorred."
::= { raisecomFanMonitorGlobalGroup 3 }
raisecomFanMonitorLevlNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the total number of fan speed levels."
::= { raisecomFanMonitorGlobalGroup 4 }
raisecomFanCardState OBJECT-TYPE
SYNTAX INTEGER
{
all-down(1),
all-up(2),
card1-up(3),
card2-up(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the current state of fan cards.
all_down(1) means that all fan cards are down;
all_up(2) means that all fan cards are up;
card1_up(3) means that fan card 1 is up, the others are down;
card2_up(4) means that fan card 2 is up, the others are down."
::= { raisecomFanMonitorGlobalGroup 5 }
raisecomFanCardSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"specify the identical serial number of current fan card,this
string number will be set when device leaving factory"
::= { raisecomFanMonitorGlobalGroup 6 }
raisecomFanMonitorTrapSendEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the status of sending trap"
::= {raisecomFanMonitorGlobalGroup 7 }
-- -------------------------------------------------------------
-- raisecomFanMonitorStateTable
-- -------------------------------------------------------------
raisecomFanMonitorStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomFanMonitorStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fan monitor state table."
::= { raisecomFanMonitorMibObjects 2 }
raisecomFanMonitorStateEntry OBJECT-TYPE
SYNTAX RaisecomFanMonitorStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fan monitor state entry."
INDEX { raisecomFanIndex }
::= { raisecomFanMonitorStateTable 1 }
RaisecomFanMonitorStateEntry ::= SEQUENCE {
raisecomFanIndex Unsigned32,
raisecomFanSpeedValue Unsigned32,
raisecomFanWorkState INTEGER,
raisecomFanSpeedCurrentLevel Unsigned32
}
raisecomFanIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specify the sequence number of fan."
::= { raisecomFanMonitorStateEntry 1 }
raisecomFanSpeedValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the actural speed of the current fan."
::= { raisecomFanMonitorStateEntry 2 }
raisecomFanWorkState OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
abnormal(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the current state of fan
normal(1) means the current fan operate normally;
abnormal(2) means the current fan operate abnormally"
::= { raisecomFanMonitorStateEntry 3 }
raisecomFanSpeedCurrentLevel OBJECT-TYPE
SYNTAX Unsigned32(1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the temperature scale border that match the speed levle,
based on this scale border,the current fan speed will ajusted autoly
according to the current temperature"
::= { raisecomFanMonitorStateEntry 4 }
-- -------------------------------------------------------------
-- raisecomFanSpeedLevelTable
-- -------------------------------------------------------------
raisecomFanSpeedLevelTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomFanSpeedLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"fan speed level information table."
::= { raisecomFanMonitorMibObjects 3 }
raisecomFanSpeedLevelEntry OBJECT-TYPE
SYNTAX RaisecomFanSpeedLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"fan speed level information entry."
INDEX { raisecomFanSpeedLevelIndex }
::= { raisecomFanSpeedLevelTable 1 }
RaisecomFanSpeedLevelEntry ::= SEQUENCE {
raisecomFanSpeedLevelIndex Unsigned32,
raisecomFanSpeedDueValue Unsigned32,
raisecomFanSpeedTemperatureScale Unsigned32
}
raisecomFanSpeedLevelIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specify the fan speed level index."
::= { raisecomFanSpeedLevelEntry 1 }
raisecomFanSpeedDueValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the speed value that match the fan levle index.
this value can ben get from a new or normal fan ,not an used
fan ,because the used fan may be aged"
::= { raisecomFanSpeedLevelEntry 2 }
raisecomFanSpeedTemperatureScale OBJECT-TYPE
SYNTAX Unsigned32(45..75)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the temperature scale border that match the speed levle,
based on this scale border,the current fan speed will ajusted autoly
according to the current temperature"
::= { raisecomFanSpeedLevelEntry 3 }
END