mibs/MIBS/ruckus/RUCKUS-SYSTEM-MIB

255 lines
5.4 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
--
-- Copyright (c) 2010 by Ruckus Wireless, Inc.
-- All Rights Reserved
--
RUCKUS-SYSTEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
ruckusCommonSystemModule
FROM RUCKUS-ROOT-MIB
TruthValue,
DisplayString
FROM SNMPv2-TC
OBJECT-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF
MODULE-IDENTITY,
OBJECT-TYPE,
Unsigned32
FROM SNMPv2-SMI;
ruckusSystemMIB MODULE-IDENTITY
LAST-UPDATED "201010150800Z"
ORGANIZATION "Ruckus Wireless, Inc."
CONTACT-INFO
"Ruckus Wireless Inc.
Postal:
880 W Maude Ave
Sunnyvale, CA 94085
USA
EMail: support@ruckuswireless.com
Phone: +1-650-265-4200"
DESCRIPTION
"Ruckus system objects."
::= { ruckusCommonSystemModule 1 }
-- Groups
--
ruckusSystemObjects OBJECT IDENTIFIER ::= { ruckusSystemMIB 1 }
ruckusSystemInfo OBJECT IDENTIFIER ::= { ruckusSystemObjects 1 }
ruckusSystemServices OBJECT IDENTIFIER ::= { ruckusSystemObjects 2 }
ruckusSystemCommands OBJECT IDENTIFIER ::= { ruckusSystemObjects 3 }
ruckusSystemEvents OBJECT IDENTIFIER ::= { ruckusSystemMIB 2 }
-- System Info
--
ruckusSystemCPUUtil OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CPU utilization."
::= { ruckusSystemInfo 1 }
ruckusSystemMemoryUtil OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Memory utilization."
::= { ruckusSystemInfo 2 }
-- System Services
--
ruckusSystemHTTP OBJECT IDENTIFIER ::= { ruckusSystemServices 1 }
ruckusSystemHTTPS OBJECT IDENTIFIER ::= { ruckusSystemServices 2 }
ruckusSystemTelnet OBJECT IDENTIFIER ::= { ruckusSystemServices 3 }
ruckusSystemSSH OBJECT IDENTIFIER ::= { ruckusSystemServices 4 }
ruckusSystemBonjour OBJECT IDENTIFIER ::= { ruckusSystemServices 5 }
ruckusSystemSyslog OBJECT IDENTIFIER ::= { ruckusSystemServices 6 }
ruckusSystemNTP OBJECT IDENTIFIER ::= { ruckusSystemServices 7 }
ruckusSystemFlexMaster OBJECT IDENTIFIER ::= { ruckusSystemServices 8 }
ruckusSystemHTTPStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable HTTP service."
DEFVAL { true }
::= { ruckusSystemHTTP 1 }
ruckusSystemHTTPSStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable HTTPS service."
DEFVAL { true }
::= { ruckusSystemHTTPS 1 }
ruckusSystemTelnetStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable Telnet service."
DEFVAL { true }
::= { ruckusSystemTelnet 1 }
ruckusSystemSSHStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable SSH service."
DEFVAL { true }
::= { ruckusSystemSSH 1 }
ruckusSystemBonjourStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable Bonjour service."
DEFVAL { true }
::= { ruckusSystemBonjour 1 }
ruckusSystemSyslogStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable Syslog service."
DEFVAL { true }
::= { ruckusSystemSyslog 1 }
ruckusSystemSyslogServerIP OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2..40))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP(v4 or v6) of syslog server."
::= { ruckusSystemSyslog 2 }
ruckusSystemSyslogServerPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port of syslog server."
::= { ruckusSystemSyslog 3 }
ruckusSystemNTPStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable/disable NTP service."
DEFVAL { true }
::= { ruckusSystemNTP 1 }
ruckusSystemNTPGMTTime OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GMT time."
::= { ruckusSystemNTP 2 }
ruckusSystemNTPActiveServer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Active NTP server."
::= { ruckusSystemNTP 3 }
ruckusSystemNTPUpdate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Update GMT time."
::= { ruckusSystemNTP 4 }
ruckusSystemFlexMasterURL OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Config FlexMaster server URL. URL start with 'http://' or 'https://'"
::= { ruckusSystemFlexMaster 1 }
-- System Commands
--
ruckusSystemReboot OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reboot."
DEFVAL { true }
::= { ruckusSystemCommands 1 }
ruckusSystemSetFactory OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set factory default."
DEFVAL { true }
::= { ruckusSystemCommands 2 }
ruckusSystemDHCPRenew OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Renew DHCP IP."
DEFVAL { true }
::= { ruckusSystemCommands 3 }
-- Conformance & Compliance
--
END