255 lines
5.4 KiB
Plaintext
255 lines
5.4 KiB
Plaintext
--
|
|
-- Copyright (c) 2010 by Ruckus Wireless, Inc.
|
|
-- All Rights Reserved
|
|
--
|
|
|
|
RUCKUS-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
ruckusCommonSystemModule
|
|
FROM RUCKUS-ROOT-MIB
|
|
TruthValue,
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP,
|
|
MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI;
|
|
|
|
ruckusSystemMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201010150800Z"
|
|
ORGANIZATION "Ruckus Wireless, Inc."
|
|
CONTACT-INFO
|
|
"Ruckus Wireless Inc.
|
|
|
|
Postal:
|
|
880 W Maude Ave
|
|
Sunnyvale, CA 94085
|
|
USA
|
|
|
|
EMail: support@ruckuswireless.com
|
|
|
|
Phone: +1-650-265-4200"
|
|
DESCRIPTION
|
|
"Ruckus system objects."
|
|
::= { ruckusCommonSystemModule 1 }
|
|
|
|
|
|
-- Groups
|
|
--
|
|
|
|
ruckusSystemObjects OBJECT IDENTIFIER ::= { ruckusSystemMIB 1 }
|
|
|
|
ruckusSystemInfo OBJECT IDENTIFIER ::= { ruckusSystemObjects 1 }
|
|
|
|
ruckusSystemServices OBJECT IDENTIFIER ::= { ruckusSystemObjects 2 }
|
|
|
|
ruckusSystemCommands OBJECT IDENTIFIER ::= { ruckusSystemObjects 3 }
|
|
|
|
ruckusSystemEvents OBJECT IDENTIFIER ::= { ruckusSystemMIB 2 }
|
|
|
|
|
|
-- System Info
|
|
--
|
|
|
|
ruckusSystemCPUUtil OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU utilization."
|
|
::= { ruckusSystemInfo 1 }
|
|
|
|
|
|
ruckusSystemMemoryUtil OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory utilization."
|
|
::= { ruckusSystemInfo 2 }
|
|
|
|
|
|
-- System Services
|
|
--
|
|
|
|
ruckusSystemHTTP OBJECT IDENTIFIER ::= { ruckusSystemServices 1 }
|
|
|
|
ruckusSystemHTTPS OBJECT IDENTIFIER ::= { ruckusSystemServices 2 }
|
|
|
|
ruckusSystemTelnet OBJECT IDENTIFIER ::= { ruckusSystemServices 3 }
|
|
|
|
ruckusSystemSSH OBJECT IDENTIFIER ::= { ruckusSystemServices 4 }
|
|
|
|
ruckusSystemBonjour OBJECT IDENTIFIER ::= { ruckusSystemServices 5 }
|
|
|
|
ruckusSystemSyslog OBJECT IDENTIFIER ::= { ruckusSystemServices 6 }
|
|
|
|
ruckusSystemNTP OBJECT IDENTIFIER ::= { ruckusSystemServices 7 }
|
|
|
|
ruckusSystemFlexMaster OBJECT IDENTIFIER ::= { ruckusSystemServices 8 }
|
|
|
|
ruckusSystemHTTPStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable HTTP service."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemHTTP 1 }
|
|
|
|
|
|
ruckusSystemHTTPSStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable HTTPS service."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemHTTPS 1 }
|
|
|
|
|
|
ruckusSystemTelnetStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable Telnet service."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemTelnet 1 }
|
|
|
|
|
|
ruckusSystemSSHStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable SSH service."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemSSH 1 }
|
|
|
|
|
|
ruckusSystemBonjourStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable Bonjour service."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemBonjour 1 }
|
|
|
|
|
|
ruckusSystemSyslogStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable Syslog service."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemSyslog 1 }
|
|
|
|
|
|
ruckusSystemSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (2..40))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP(v4 or v6) of syslog server."
|
|
::= { ruckusSystemSyslog 2 }
|
|
|
|
|
|
ruckusSystemSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port of syslog server."
|
|
::= { ruckusSystemSyslog 3 }
|
|
|
|
|
|
ruckusSystemNTPStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable NTP service."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemNTP 1 }
|
|
|
|
|
|
ruckusSystemNTPGMTTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GMT time."
|
|
::= { ruckusSystemNTP 2 }
|
|
|
|
|
|
ruckusSystemNTPActiveServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active NTP server."
|
|
::= { ruckusSystemNTP 3 }
|
|
|
|
|
|
ruckusSystemNTPUpdate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Update GMT time."
|
|
::= { ruckusSystemNTP 4 }
|
|
|
|
|
|
ruckusSystemFlexMasterURL OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config FlexMaster server URL. URL start with 'http://' or 'https://'"
|
|
::= { ruckusSystemFlexMaster 1 }
|
|
|
|
-- System Commands
|
|
--
|
|
|
|
ruckusSystemReboot OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reboot."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemCommands 1 }
|
|
|
|
|
|
ruckusSystemSetFactory OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set factory default."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemCommands 2 }
|
|
|
|
|
|
ruckusSystemDHCPRenew OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Renew DHCP IP."
|
|
DEFVAL { true }
|
|
::= { ruckusSystemCommands 3 }
|
|
|
|
|
|
-- Conformance & Compliance
|
|
--
|
|
|
|
END
|