mibs/MIBS/siae/SIAE-RADIO-SYSTEM-MIB

4693 lines
156 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- ----------------------------------------------------------------------------
--
-- SIAE MICROELETTRONICA s.p.a.
--
-- Via Michelangelo Buonarroti, 21
-- 20093 - Cologno Monzese
-- Milano
-- ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------
SIAE-RADIO-SYSTEM-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE,
Integer32, Counter32
FROM SNMPv2-SMI
InterfaceIndexOrZero
FROM IF-MIB
TEXTUAL-CONVENTION,
DisplayString, RowStatus, StorageType
FROM SNMPv2-TC
siaeMib
FROM SIAE-TREE-MIB
AlarmStatus, AlarmSeverityCode, alarmTrap
FROM SIAE-ALARM-MIB
equipIpSnmpAgentAddress
FROM SIAE-EQUIP-MIB;
radioSystem MODULE-IDENTITY
LAST-UPDATED "201607140000Z"
ORGANIZATION "SIAE MICROELETTRONICA spa"
CONTACT-INFO
"SIAE MICROELETTONICA s.p.a.
Via Michelangelo Buonarroti, 21
20093 - Cologno Monzese
Milano - ITALY
Phone : +39-02-27325-1
E-mail: help@siaemic.com
"
DESCRIPTION
"Radio System MIB.
"
REVISION "201607140000Z"
DESCRIPTION
"MIB version 01.00.05
- added radioXpd in radioStatusTable
- deprecated linkXpd in linkStatusTable
"
REVISION "201602290000Z"
DESCRIPTION
"MIB version 01.00.04
- Added linkXpd to linkStatusTable
- changed MAX-ACCESS clause of linkChRadioSettingsIdx from
read-only to read-create
- Fixed DESCRIPTION of linkSettingsTable
"
REVISION "201509150000Z"
DESCRIPTION
"Fixed DESCRIPTION of radioTxChannelSpacing
"
REVISION "201506180000Z"
DESCRIPTION
"MIB version 01.00.03
- Added linkConfigurationInProgress and
linkConfigurationInProgressTrapNotification
- Added radio radioRxBerThresholdTable
- Added fadeMarginMeasure
- Deprecated linkFadeMarginMeasure
- Added table radioLoopCapabilityTable
- Added table sspTable
- Added table stm1BulkSettingsTable
- Added table linkE1vsSTM1CapacityTable
- Deprecated linkAcmMaxTDMCapacity
- Deprecated linkTfcTable, linkProTable and linkProMaintTable.
- Added linkTfcV2Table, linkProV2Table and linkProMaintV2Table
in order to replace deprecated tables.
- Added channelSpacingSelection
"
REVISION "201503230000Z"
DESCRIPTION
"Removed alarmTrapNumber from TRAPs and IMPORTS.
"
REVISION "201411050000Z"
DESCRIPTION
"MIB version 01.00.02
Changes for support of modulation 4096QAM:
- DESCRIPTION of linkBandwidthAndModulation
- ModulationMap TEXTUAL-CONVENTION
- BitsPerSymbol TEXTUAL-CONVENTION
Changes for support of channel spacing 60MHz and 80MHz:
- DESCRIPTION of linkBandwidthAndModulation
- ChannelSpacing TEXTUAL-CONVENTION
"
REVISION "201409160000Z"
DESCRIPTION
"MIB version 01.00.01
- Added combinedRadioCapabilitiesTable, combinedRadioFrequencyTable,
combinedRadioDuplexFrequencyTable and combinedRadioPowerScalingTable
- Declared deprecated linkCapabilitiesTable, linkFrequencyTable,
linkDuplexFrequencyTable, linkAcmPowerScaling,
linkAcmAtpcRxPowerScaling and linkAcmPowerRange.
- Added linkNotMatchingRadiosAlarm and
linkNotMatchingRadiosAlarmSeverityCode
"
REVISION "201404010000Z"
DESCRIPTION
"Initial version 01.00.00.
"
::= { siaeMib 80 }
----------------------------------------------------------------------------------
-- Textual Conventions
----------------------------------------------------------------------------------
ChannelSpacing ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This TC describes a data type which identifies a RF channel spacing.
"
SYNTAX INTEGER {
-- ETSI
bw3M5Hz (0),
bw7Mhz (1),
bw14MHz (2),
bw28MHz (3),
bw40MHz (5),
bw56MHz (4),
bw112MHz (6),
bw250Mhz (7),
bw500Mhz (8),
bw750Mhz (9),
bw1000Mhz (10),
-- FCC
bw10Mhz (11),
bw20Mhz (12),
bw30Mhz (13),
bw50Mhz (14),
bw60Mhz (15),
bw80Mhz (16)
}
ModulationMap ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the radioBranchModulationMap
and radioBranchRefModulationMap objects.
"
SYNTAX BITS {
modBPSK (0),
mod4QAM (1),
mod8PSK (2),
mod16QAM (3),
mod32QAM (4),
mod64QAM (5),
mod128QAM (6),
mod256QAM (7),
mod512QAM (8),
mod1024QAM (9),
mod2048QAM (10),
mod4096QAM (11)
}
ConfigMismatchReason ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used to specify the cause of Config Mismatch Alarm,
that is the mismatch between the radio link capability and the current
local and remote configuration.
- securityMismatch(0)
Copyright violation
- frequencyFailMismatch(1)
Configured frequency is out of Filter-Bandwidth
- frequencyAlertMismatch(2)
Configured frequency across Filter-Bandwidth
- ptxMismatch(3)
Tx power configured incongruent with RF Tx power limits
- channelSpacingAndModulationMismatch(4)
Bandwidth and/or modulation configured is invalid
(RF doesn't support it)
- remoteConfigurationMismatch(5)
Incongruence between the couple of Terminal Radio Unit (TRU)
in the link:
- Frequency Incongruent (Freq)
- Reference Bandwidth and Modulation incongruent
- Acm-Tx map in congruent with remote Acm-Rx map
- acmMismatch(6)
Obsolete (no longer used)
- profileSetMismatch(7)
The selected profile set is not supported by the TRU
"
SYNTAX BITS {
securityMismatch(0),
frequencyFailMismatch(1),
frequencyAlertMismatch(2),
ptxMismatch(3),
channelSpacingAndModulationMismatch(4),
remoteConfigurationMismatch(5),
acmMismatch(6),
profileSetMismatch(7)
}
RadioCapability ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the radioBranchKeyFeatures
objects.
"
SYNTAX BITS {
reserved (0),
trafficSquelch (1),
baseBandLoop (2),
maxPower (3),
carrierOnly (4),
iQLoop (5),
rfLoopGivenMod (6), -- only at a given modulation
rfLoopAnyMod (7) -- at any modulation
}
BitsPerSymbol ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"his TC describes a data type which identifies a RF channel spacing.
"
SYNTAX INTEGER {
bpsBPSK (1),
bps4QAM (2),
bps8PSK (3),
bps16QAM (4),
bps32QAM (5),
bps64QAM (6),
bps128QAM (7),
bps256QAM (8),
bps512QAM (9),
bps1024QAM (10),
bps2048QAM (11),
bps4096QAM (12)
}
Stm1IndexOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This textual convention permits the
additional value of zero to an stm1Index in stm1Table.
The value zero is object-specific and must therefore be
defined as part of the description of any object which
uses this syntax. Examples of the usage of zero might
include situations where stm-1 was unknown, or when none
or all stm-1s need to be referenced."
SYNTAX Integer32 (0..2147483647)
----------------------------------------------------------------------------------
-- radioSystem GROUP
----------------------------------------------------------------------------------
--
-- This group contains all the objects that are specific of the radio system
--
----------------------------------------------------------------------------------
------ Beginning --------------------------------------------------------------
radioSystemMibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01."
::= {radioSystem 1}
------- Begin of radioTable
--
radioTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of radio interface entries. This table is useful
to show the manager all the available radio interfaces
on the equipment. Moreover it is a reference for
Performance Monitoring (PWR and G828).
"
::= {radioSystem 2}
radioEntry OBJECT-TYPE
SYNTAX RadioEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular radio interface.
"
INDEX {radioIndex}
::= {radioTable 1}
RadioEntry ::=
SEQUENCE {
radioIndex Integer32,
radioLabel DisplayString,
radioType INTEGER,
radioIfIndex InterfaceIndexOrZero,
radioStorageType StorageType
}
radioIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each radio
interface. It is recommended that values are assigned
contiguously starting from 1.
"
::= {radioEntry 1}
radioLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the radio
interface. This string should include the name of the
manufacturer, the product name and the version of the
interface hardware/software.
"
::= {radioEntry 2}
radioType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
analogRadio(2), -- analogic radio --
digitalRadio(3), -- digital radio --
xpicRadio(4) -- xpic radio --
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of interface.
"
::= {radioEntry 3}
radioIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines a greater than zero value
to identify an interface in ifTable or a zero
value if ifTable is not supported.
"
::= {radioEntry 4}
radioStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The storage type of this conceptual row. Conceptual
rows having the value 'permanent' need not allow
write-access to any columnar objects in the row.
"
::= {radioEntry 5}
--
------- End of radioTable
------- Begin of xpicTable
--
xpicTable OBJECT-TYPE
SYNTAX SEQUENCE OF XpicEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of xpic radio interface entries. If a manager
wants to make an xpic link, it should only add a
particular xpic radio interface to an xpic link.
"
::= {radioSystem 3}
xpicEntry OBJECT-TYPE
SYNTAX XpicEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular xpic radio interface.
"
INDEX {xpicIndex}
::= {xpicTable 1}
XpicEntry ::=
SEQUENCE {
xpicIndex Integer32,
xpicRadioIdx Integer32,
xpicRowstatus RowStatus
}
xpicIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each xpic radio
interface. It is recommended that values are assigned
contiguously starting from 1.
"
::= {xpicEntry 1}
xpicRadioIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of xpic radio interface, corresponding
to an available xpic radio interface in radioTable.
"
::= {xpicEntry 2}
xpicRowstatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this conceptual row in xpicTable.
"
::= {xpicEntry 3}
--
------- End of xpicTable
------- Begin of xpicChTable
--
xpicChTable OBJECT-TYPE
SYNTAX SEQUENCE OF XpicChEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of xpic channel entries. This table maps
each xpic radio in respective xpic radio interface.
"
::= {radioSystem 4}
xpicChEntry OBJECT-TYPE
SYNTAX XpicChEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular xpic channel. It defines radio interface and
polarization for a given xpic channel.
"
INDEX {xpicIndex,
xpicChPolIndex}
::= {xpicChTable 1}
XpicChEntry ::=
SEQUENCE {
xpicChPolIndex Integer32,
xpicChRadioIdx Integer32,
xpicChRowstatus RowStatus
}
xpicChPolIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the xpic radio polarization.
"
::= {xpicChEntry 1}
xpicChRadioIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Xpic radio interface, corresponding to a radio interface
in radioTable, used to make up the given xpic radio interface.
"
::= {xpicChEntry 2}
xpicChRowstatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this conceptual row in xpicChTable.
"
::= {xpicChEntry 3}
--
------- End of xpicChTable
linkAvailableIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows an index which is available for creation of a new link
in the system. It shows the smallest available index.
Any attempt to create a link with a different index results
in a failure.
"
::= {radioSystem 5}
------- Begin of linkTable
--
linkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of link entries.
"
::= {radioSystem 6}
linkEntry OBJECT-TYPE
SYNTAX LinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular link.
"
INDEX {linkIndex}
::= {linkTable 1}
LinkEntry ::=
SEQUENCE {
linkIndex Integer32,
linkType INTEGER,
linkLabel DisplayString,
linkIfIndex InterfaceIndexOrZero,
linkRowstatus RowStatus
}
linkIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each link.
Manager must use the first available index,
suggested by linkAvailableIndex.
"
::= {linkEntry 1}
linkType OBJECT-TYPE
SYNTAX INTEGER {
radio1p0(1), -- 1+0
radio1p1HS(2), -- 1+1 Hot Standby
radio1p1FD(3), -- 1+1 Frequency Diversity
radio2p0Xpic(4), -- 2+0 XPIC
radio2p2XpicHS(5), -- 2+2 XPIC Hot Standby
radio2p2XpicFD(6), -- 2+2 XPIC Frequency Diversity
radioNp1(7) -- N+1
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies link type. Supported link types are:
single link, 1+1 Hot Standby, 1+1 Frequency Diversity, 2+0 XPIC,
2+2 XPIC Hot Standby, 2+2 XPIC Frequency Diversity and N+1.
"
DEFVAL {radio1p0}
::= {linkEntry 2}
linkLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual string containing information about the link.
This string should give more details about link specific
parameters.
"
DEFVAL {""}
::= {linkEntry 3}
linkIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines a greater than zero value
to identify a link in ifTable or a zero
value if ifTable is not supported.
"
DEFVAL {0}
::= {linkEntry 4}
linkRowstatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row of linkTable. This object is used to manage the
creation and deletion of conceptual rows in linkTable.
To create a row in this table, a manager should set rowstatus to
createAndWait(5) and choose a link type. Respective entries in
linkSettingsTable, linkStatusTable and tdmSettingsTable will be
created by agent.In case of protection links proper entries in
linkProtectionTable will be also created.
Until instances of all corresponding columns are appropriately
configured, the value of the corresponding instance of rowstatus
is notReady(3).
When there is sufficient information to (attempt to) make the
conceptual row available for use by the managed device,
then the rowstatus column turns into notInService(2); manager
must set rowstatus to active(1) to make the conceptual row
active.
The contents of linkSettingsTable and radioSettingsTable can be
changed only if this object is notInService(2).
"
::= {linkEntry 5}
--
------- End of linkTable
------- Begin of linkChTable
--
linkChTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkChEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of link channel entries.
"
::= {radioSystem 7}
linkChEntry OBJECT-TYPE
SYNTAX LinkChEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular link channel.
"
INDEX {linkIndex,
linkChIndex}
::= {linkChTable 1}
LinkChEntry ::=
SEQUENCE {
linkChIndex Integer32,
linkChRadioIdx Integer32,
linkChRadioSettingsIdx Integer32,
linkChRowstatus RowStatus
}
linkChIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Channel Index.
"
::= {linkChEntry 1}
linkChRadioIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Radio channel index that corresponds to an
available radio interface in radioTable.
"
::= {linkChEntry 2}
linkChRadioSettingsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Radio Settings Index. This object is a foreign
key for a corresponding radioSettingsTable entry,
which is automatically created by agent.
"
DEFVAL {0}
::= {linkChEntry 3}
linkChRowstatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row of linkChTable. This object is used
to manage the creation and deletion of conceptual rows in
linkChTable.
To create a row in this table, a manager should set rowstatus to
createAndWait(5). Until instances of all corresponding columns
are appropriately configured, the value of the corresponding
instance of rowstatus is notReady(3).
When there is sufficient information to (attempt to) make the
conceptual row available for use by the managed device,
then the rowstatus column turns into notInService(2); manager
must set rowstatus to active(1) to make the conceptual row
active.
The content of radioSettingsTable can be changed only if this
object is notInService(2).
"
::= {linkChEntry 4}
--
------- End of linkChTable
------- Begin of linkSettingsTable
--
linkSettingsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkSettingsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with link settings entries. This table contains all
parameters of a radio frequency link. The content of this
table can be changed by a manager if linkRowStatus is
notInService(2)."
::= {radioSystem 8}
linkSettingsEntry OBJECT-TYPE
SYNTAX LinkSettingsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Radio link entry"
INDEX {linkIndex}
::= {linkSettingsTable 1}
LinkSettingsEntry ::=
SEQUENCE {
linkBandwidthAndModulation Integer32,
linkAcmEngineEnable INTEGER,
linkTxUpperProfile INTEGER,
linkTxLowerProfile INTEGER,
linkId INTEGER,
linkTxPwrThresh INTEGER,
linkRxPwrThresh INTEGER,
linkSynchSetupProtocolEnable INTEGER,
linkProfilesSetSelection INTEGER,
linkXpicControlProcedure INTEGER
}
linkBandwidthAndModulation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Link Modulation and Bandwidth (channel spacing).
The value of this object value is computed by:
65536*modulation+bandwidth
where bandwidth selection is:
0 = 3.5Mhz
1 = 7MHz
2 = 14MHz
3 = 28MHz
4 = 56MHz
5 = 10MHz
6 = 20MHz
7 = 30MHz
8 = 40MHz
9 = 50MHz
10 = 112Mhz
11 = 250Mhz
12 = 500Mhz
13 = 750Mhz
14 = 1Ghz
15 = 60MHz
16 = 80MHz
and modulation is in bit-per-symbol:
1 = BPSK
2 = 4QAM
3 = 8PSK
4 = 16QAM
5 = 32QAM
6 = 64QAM
7 = 128QAM
8 = 256QAM
9 = 512QAM
10 = 1024QAM
11 = 2048QAM.
12 = 4096QAM.
Examples:
250Mhz-4QAM (131083),
500Mhz-4QAM (131084),
250Mhz-16QAM (262155),
500Mhz-64QAM (393228).
Note: 0 bit-per-symbol is not possible,
so value 0 is used for
BandwidthAndModulation unassigned."
::= {linkSettingsEntry 1}
linkAcmEngineEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to enable/disable the ACM engine"
DEFVAL { disable }
::= {linkSettingsEntry 2}
linkTxUpperProfile OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object (and linkTxLowerProfile object) is used to
restrict the TX profile range when ACM is enabled."
::= {linkSettingsEntry 3}
linkTxLowerProfile OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object (and linkTxUpperProfile object) is used to
restrict the TX profile range when ACM is enabled."
::= {linkSettingsEntry 4}
linkId OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Link Identification (value 0..255)"
DEFVAL {0}
::= {linkSettingsEntry 5}
linkTxPwrThresh OBJECT-TYPE
SYNTAX INTEGER (3..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold (value +3 , +15 dB) relative to nominal value of the TX power
below wich the related alarm is set."
DEFVAL {3}
::= {linkSettingsEntry 6}
linkRxPwrThresh OBJECT-TYPE
SYNTAX INTEGER (-99..-40)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold (value -40 , -99 dBm) for RX power below wich the related
alarm is set."
DEFVAL {-70}
::= {linkSettingsEntry 7}
linkSynchSetupProtocolEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Synchronization Setup Protocol (SSP) control"
DEFVAL {disable}
::= {linkSettingsEntry 8}
linkProfilesSetSelection OBJECT-TYPE
SYNTAX INTEGER {
highThroughput (1),
highGain (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Selection of the working profile set between high gain
(max robustness) profile set and high throughput (max
capacity) profile set. The set of profiles high gain
features a greater robustness against to the set of
profiles high throughput.
For radio systems that do not have more sets of profiles,
this object becomes read only and its reading shows the
only one set of profiles supported.
"
DEFVAL {highThroughput}
::= {linkSettingsEntry 9}
linkXpicControlProcedure OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set by manager to enable\disable XPIC alarm control procedure.
Only for XPIC configurations."
DEFVAL { enable }
::= {linkSettingsEntry 10}
--
------- End of linkSettingsTable
------- Begin of radioSettingsTable
--
radioSettingsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioSettingsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with radio settings entries. This table contains all
parameters of a radio terminal. The content of this table
can be changed only linkRowStatus is notInService(2)"
::= {radioSystem 9}
radioSettingsEntry OBJECT-TYPE
SYNTAX RadioSettingsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Radio terminal entry"
INDEX {radioSettingsIndex}
::= {radioSettingsTable 1}
RadioSettingsEntry ::=
SEQUENCE {
radioSettingsIndex Integer32,
radioSettingsRowStatus RowStatus,
radioSettingsLabel DisplayString,
radioTxFrequency INTEGER,
radioDuplexFrequency INTEGER,
radioTxAttenuation INTEGER,
radioAtpcManual INTEGER,
radioAtpcPwrHigh Integer32,
radioAtpcPwrLow Integer32,
radioAtpcRange Integer32,
radioFreqTableSelection ChannelSpacing
}
radioSettingsIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radio settings index.
"
::= {radioSettingsEntry 1}
radioSettingsRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row.
"
::= {radioSettingsEntry 2}
radioSettingsLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the radio
interface.
"
::= {radioSettingsEntry 3}
radioTxFrequency OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Transmitted frequency in KHz. Null value means invalid frequency."
DEFVAL {0}
::= {radioSettingsEntry 4}
radioDuplexFrequency OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of duplex frequency in KHz. -2 means not set."
DEFVAL {-2}
::= {radioSettingsEntry 5}
radioTxAttenuation OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Transmitter attenuation relative to nominal power (dBm)."
::= {radioSettingsEntry 6}
radioAtpcManual OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enables/disables Atpc Manual operation."
DEFVAL {disable}
::= {radioSettingsEntry 7}
radioAtpcPwrHigh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ATPC Control - Local Rx Power High (dBm range -30 to -80) -."
DEFVAL {-40}
::= {radioSettingsEntry 8}
radioAtpcPwrLow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ATPC Control - Local Rx Power Low (dBm range -30 to -80) -."
DEFVAL {-60}
::= {radioSettingsEntry 9}
radioAtpcRange OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the range of the ATPC regulation (expressed in dB) with respect
to the current value of maximum Tx output, that is intended as the upper
limit of the range. A null value means no limit: the lower limit
of the range is equal to minimum Ptx."
DEFVAL {0}
::= {radioSettingsEntry 10}
radioFreqTableSelection OBJECT-TYPE
SYNTAX ChannelSpacing
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RadioFrequencyTable key (channel spacing & modulation) selection."
::= {radioSettingsEntry 11}
--
------- End of radioSettingsTable
------- Begin of tdmSettingsTable
--
tdmSettingsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmSettingsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with tdm settings entries.
"
::= {radioSystem 10}
tdmSettingsEntry OBJECT-TYPE
SYNTAX TdmSettingsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing tdm parameters for a particular link.
"
INDEX {linkIndex,
tdmPolIndex}
::= {tdmSettingsTable 1}
TdmSettingsEntry ::=
SEQUENCE {
tdmPolIndex Integer32,
tdmE1Channel Integer32,
tdmE1Framer INTEGER
}
tdmPolIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Polarization index.
"
::= {tdmSettingsEntry 1}
tdmE1Channel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of E1 channels. This object is used to define the capacity
of E1 tributaries assigned to a given radio link. The capacity is
changed in steps of E1 (2Mbit/s).
"
DEFVAL {0}
::= {tdmSettingsEntry 2}
tdmE1Framer OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to attach the framer to a given E1.
"
DEFVAL {disable}
::= {tdmSettingsEntry 3}
--
------- End of tdmSettingsTable
------- Begin of radioCapabilitiesTable
--
radioCapabilitiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioCapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with RadioCapabilities entries: there is an entry for each
radioTable rows."
::= {radioSystem 11}
radioCapabilitiesEntry OBJECT-TYPE
SYNTAX RadioCapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RadioCapabilities entry."
INDEX {radioIndex}
::= {radioCapabilitiesTable 1}
RadioCapabilitiesEntry ::=
SEQUENCE {
radioCapabilitiesCapability RadioCapability,
radioCapabilitiesTxMinFrequency Integer32,
radioCapabilitiesTxMaxFrequency Integer32,
radioCapabilitiesStepFrequency Integer32,
radioCapabilitiesMinPtxNominalValue Integer32,
radioCapabilitiesMaxPtxNominalValue Integer32,
radioCapabilitiesExtendedMinPwr Integer32
}
radioCapabilitiesCapability OBJECT-TYPE
SYNTAX RadioCapability
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit map to describe the radio features."
::= {radioCapabilitiesEntry 1}
radioCapabilitiesTxMinFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum of available channel frequency in KHz."
::= {radioCapabilitiesEntry 2}
radioCapabilitiesTxMaxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum of available channel frequency in KHz."
::= {radioCapabilitiesEntry 3}
radioCapabilitiesStepFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum frequency step in KHz."
::= {radioCapabilitiesEntry 4}
radioCapabilitiesMinPtxNominalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum nominal Ptx in dBm."
::= {radioCapabilitiesEntry 5}
radioCapabilitiesMaxPtxNominalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum nominal Ptx in dBm."
::= {radioCapabilitiesEntry 6}
radioCapabilitiesExtendedMinPwr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum extended Ptx power for fade margin."
::= {radioCapabilitiesEntry 7}
--
------- End of radioCapabilitiesTable
------- Begin of radioStatusTable
--
radioStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with RadioStatus records: one record for 1+0 configuration and
two record for 1+1 configuration."
::= {radioSystem 12}
radioStatusEntry OBJECT-TYPE
SYNTAX RadioStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RadioStatus record."
INDEX {radioIndex}
::= {radioStatusTable 1}
RadioStatusEntry ::=
SEQUENCE {
radioCurrentDuplexFrequency Integer32,
radioTxChannelSpacing Integer32,
radioPrx Integer32,
radioPtx Integer32,
radioNormalizedMse Integer32,
radioRxActiveStatus INTEGER,
radioTxActiveStatus INTEGER,
radioCableOpenAlarm AlarmStatus,
radioCableShortAlarm AlarmStatus,
radioInvalidFrequencyAlarm AlarmStatus,
radioBaseBandRxAlarm AlarmStatus,
radioModulatorFailAlarm AlarmStatus,
radioDemodulatorFailAlarm AlarmStatus,
radioRxPowerLowAlarm AlarmStatus,
radioTxPowerLowAlarm AlarmStatus,
radioRemDemodulatorFailAlarm AlarmStatus,
radioVcoFailAlarm AlarmStatus,
radioRxIFAgcAlarm AlarmStatus,
radioTxIFAgcAlarm AlarmStatus,
radioIduOduCommunicationAlarm AlarmStatus,
radioOduIduCommunicationAlarm AlarmStatus,
radioLocalOduAlarmSynthesis AlarmStatus,
radioRemoteOduAlarmSynthesis AlarmStatus,
radioConfigMismatchAlarm AlarmStatus,
radioConfigAlarmReason ConfigMismatchReason,
radioRxQualityLowAlarm AlarmStatus,
radioRxQualityWarningAlarm AlarmStatus,
radioXpd Integer32
}
radioCurrentDuplexFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Spacing between transmitted and received frequency in KHz."
::= {radioStatusEntry 1}
radioTxChannelSpacing OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Half of transmitted signal channel spacing in KHz."
::= {radioStatusEntry 2}
radioPrx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received power level (dBm)."
::= {radioStatusEntry 3}
radioPtx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitted power level (dBm)."
::= {radioStatusEntry 4}
radioNormalizedMse OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Normalized MSE (Mean Squared Error) is an indicator of the Signal
to Noise (S/N) ratio. It's in 0.1 dB steps"
::= {radioStatusEntry 5}
radioRxActiveStatus OBJECT-TYPE
SYNTAX INTEGER {
cleared (1),
active (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receiver Active status with associated Severity
In 1+1 Hot Standby radio system, only one RX is active.
RXs are active in other configurations of the radio system.
"
::= {radioStatusEntry 6}
radioTxActiveStatus OBJECT-TYPE
SYNTAX INTEGER {
cleared (1),
active (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitter Active status with associated Severity.
In 1+1 Hot Standby radio system, only one TX is active.
TXs are active in other configurations of the radio system.
"
::= {radioStatusEntry 7}
radioCableOpenAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cable connnecting ODU is open: alarm status with associated
severity.
"
::= {radioStatusEntry 8}
radioCableShortAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cable connnecting ODU is in short-circuit: alarm status
with associated severity.
"
::= {radioStatusEntry 9}
radioInvalidFrequencyAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Invalid frequency alarm with associated severity."
::= {radioStatusEntry 10}
radioBaseBandRxAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Base Band Rx alarm status with associated severity."
::= {radioStatusEntry 11}
radioModulatorFailAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator Fail Alarm status with associated severity."
::= {radioStatusEntry 12}
radioDemodulatorFailAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Demodulator Fail Alarm status with associated severity."
::= {radioStatusEntry 13}
radioRxPowerLowAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receiver power low alarm status with associated severity."
::= {radioStatusEntry 14}
radioTxPowerLowAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmitter power low alarm status with associated severity."
::= {radioStatusEntry 15}
radioRemDemodulatorFailAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote Demodulator Fail Alarm status with associated severity."
::= {radioStatusEntry 16}
radioVcoFailAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RT VCO fail alarm status with associated severity."
::= {radioStatusEntry 17}
radioRxIFAgcAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RT Rx IF AGC fail alarm status with associated severity."
::= {radioStatusEntry 18}
radioTxIFAgcAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RT Tx IF AGC fail alarm status with associated severity."
::= {radioStatusEntry 19}
radioIduOduCommunicationAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Communication from IDU towards ODU is down"
::= {radioStatusEntry 20}
radioOduIduCommunicationAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Communication from ODU towards IDU is down"
::= {radioStatusEntry 21}
radioLocalOduAlarmSynthesis OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Local ODU alarm synthesis with associated severity."
::= {radioStatusEntry 22}
radioRemoteOduAlarmSynthesis OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Local ODU alarm synthesis alarm status with associated severity."
::= {radioStatusEntry 23}
radioConfigMismatchAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Config Mismatch alarm status with associated severity and related map."
::= {radioStatusEntry 24}
radioConfigAlarmReason OBJECT-TYPE
SYNTAX ConfigMismatchReason
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit map to describe the Config Mismatch Alarm"
-- DEFVAL { { } }
::= {radioStatusEntry 25}
radioRxQualityLowAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High BER Alarm status with associated severity."
::= {radioStatusEntry 26}
radioRxQualityWarningAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RX signal is close to cause errors on payload."
::= {radioStatusEntry 27}
radioXpd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cross-Polarization Discrimination, in tenths of dB, is the
difference between the received signal power of the
co-polarized main beam, and it componemt received on the
cross-polarized signal.
This object shows an extimated value of the XPD performed by
the cross-polarization interference canceller (XPIC).
This means that the measure is reliable if:
- XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5),
or radio2p2XpicFD(6))
- Alarm radioDemodulatorFailAlarm is cleared.
- XPD is not too high, since without cross-polar interference
the canceller is not able to works well. Basically, in this
condition, the extimated XPD is greater than the real one.
"
::= {radioStatusEntry 28}
--
------- End of radioStatusTable
--
-- MAINTENANCE TABLE
--
------- Begin of radioMaintTable
--
radioMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with Command for maintenance of radio branch.
Objects in this table is not persistent. An Instance of this
table is created on creation of radioBranchEntry"
::= {radioSystem 13}
radioMaintEntry OBJECT-TYPE
SYNTAX RadioMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Radio branch Maintenance record."
INDEX {radioIndex}
::= {radioMaintTable 1}
RadioMaintEntry ::=
SEQUENCE {
radioTxStatus INTEGER,
radioCarrierOnly INTEGER,
radioLoop INTEGER,
radioRFLoopTestResult INTEGER,
radioRFLoopTestPercTime INTEGER,
radioRtPsuOff INTEGER,
radioLom INTEGER,
radioXpic INTEGER
}
radioTxStatus OBJECT-TYPE
SYNTAX INTEGER {
transmitterOff (1),
transmitterOn (2),
permanentOff (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmitter status control.
The value transmitterOff(1) is related to a manual operation.
The value permanentOff(3) is persistent across restart.
"
DEFVAL {transmitterOn}
::= {radioMaintEntry 1}
radioCarrierOnly OBJECT-TYPE
SYNTAX INTEGER {
carrierOnlyOff (1),
carrierOnlyOn (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Carrier only transmission control."
DEFVAL {carrierOnlyOff}
::= {radioMaintEntry 2}
radioLoop OBJECT-TYPE
SYNTAX INTEGER {
loopOff (1),
rfLoop (2),
iqLoop (3),
baseBandLoop (4),
rfLoopAtFixedMod (6),
baseBandLoopEthSquelch (7),
rfLoopAtFixedModEthSquelch(8),
iqloopEthSquelch (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the Radio Branch loops."
DEFVAL {loopOff}
::= {radioMaintEntry 3}
radioRFLoopTestResult OBJECT-TYPE
SYNTAX INTEGER {
testNone (0),
testRunning (1),
testNotPossible (2),
testPassed (3),
testFail (4),
testInterrupted (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radio branch RT loop test result."
DEFVAL {testNone}
::= {radioMaintEntry 4}
radioRFLoopTestPercTime OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radio branch RT loop test time percentage"
::= {radioMaintEntry 5}
radioRtPsuOff OBJECT-TYPE
SYNTAX INTEGER {
rtPsuOff (1),
rtPsuOn (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It switches on/off the Rt power supply"
DEFVAL {rtPsuOn}
::= {radioMaintEntry 6}
radioLom OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to enable the IP packet forwarding towards Radio."
DEFVAL {disable}
::= {radioMaintEntry 7}
radioXpic OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable of the cross polarization interference cancellation of this
radio. The value disable is tied to a manual operation
(ManOpRecord). This object is applicable only if thiis radio
belongs to a 2+0 XPIC or 2+2 XPIC link."
::= {radioMaintEntry 8}
--
------- End of radioMaintTable
------- Begin of radioFrequencyTable
--
radioFrequencyTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Availables channels for selected channel spacing and modulation
(see leaf radioFreqTableSelection)."
::= {radioSystem 14}
radioFreqTabEntry OBJECT-TYPE
SYNTAX RadioFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RadioFreqTab record."
INDEX {radioIndex, radioFreqChannelId}
::= {radioFrequencyTable 1}
RadioFreqEntry ::=
SEQUENCE {
radioFreqChannelId Integer32,
radioFreqChannelNum Integer32,
radioFreqValue Integer32
}
radioFreqChannelId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table"
::= {radioFreqTabEntry 1}
radioFreqChannelNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Available channel number."
::= {radioFreqTabEntry 2}
radioFreqValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency related to radioFreqChannelNum."
::= {radioFreqTabEntry 3}
--
------- End of radioFrequencyTable
------- Begin of radioDuplexFrequencyTable
--
radioDuplexFrequencyTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioDuplexFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with available duplex frequencies. Duplex frequency is
the absolute value of difference between RX and TX frequency."
::= {radioSystem 15}
radioDuplexFreqEntry OBJECT-TYPE
SYNTAX RadioDuplexFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Duplex Frequency entry. There is an entry for each available
duplex frequency."
INDEX {radioIndex, radioDuplexFreqId}
::= {radioDuplexFrequencyTable 1}
RadioDuplexFreqEntry ::=
SEQUENCE {
radioDuplexFreqId Integer32,
radioDuplexFreqValue Integer32
}
radioDuplexFreqId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= {radioDuplexFreqEntry 1}
radioDuplexFreqValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duplex frequency in KHz."
::= {radioDuplexFreqEntry 2}
--
------- End of radioDuplexFrequencyTable
------- Begin of radioModulationTable
--
radioModulationTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of modulations related to channel spacing."
::= {radioSystem 16}
radioModulationEntry OBJECT-TYPE
SYNTAX RadioModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"radioModulation record."
INDEX {radioIndex, radioChannelSpacing}
::= {radioModulationTable 1}
RadioModulationEntry ::=
SEQUENCE {
radioChannelSpacing ChannelSpacing,
radioModulationMap ModulationMap,
radioRefModulationMap ModulationMap
}
radioChannelSpacing OBJECT-TYPE
SYNTAX ChannelSpacing
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the channel spacing."
::= {radioModulationEntry 1}
radioModulationMap OBJECT-TYPE
SYNTAX ModulationMap
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"List of modulations in the radioChanSpacing"
::= {radioModulationEntry 2}
radioRefModulationMap OBJECT-TYPE
SYNTAX ModulationMap
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"List of modulations that can be selected as reference
in the radioChanSpacingId"
::= {radioModulationEntry 3}
--
------- End of radioModulationTable
------- Begin of linkStatusTable
--
linkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with LinkStatusEntry."
::= {radioSystem 17}
linkStatusEntry OBJECT-TYPE
SYNTAX LinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link status entry"
INDEX {linkIndex,
linkPolIndex }
::= {linkStatusTable 1}
LinkStatusEntry ::=
SEQUENCE{
linkPolIndex INTEGER,
linkAcmRxProfile Integer32,
linkAcmTxProfile Integer32,
linkAcmRxProfileLabel DisplayString,
linkAcmTxProfileLabel DisplayString,
linkAcmRxModulation BitsPerSymbol,
linkAcmTxModulation BitsPerSymbol,
linkAcmRxCode INTEGER,
linkAcmTxCode INTEGER,
linkTxETHCapacity Integer32,
linkRxETHCapacity Integer32,
linkTxTDMCapacity Integer32,
linkRxTDMCapacity Integer32,
linkRescueModulation BitsPerSymbol,
linkReducedCapacityAlarm AlarmStatus,
linkLinkTelemetryFailAlarm AlarmStatus,
linkIdMismatchAlarm AlarmStatus,
linkRadioEocAlarm AlarmStatus,
linkSetupMismatchAlarm AlarmStatus,
linkRescueSetupAlarm AlarmStatus,
linkXpicProcedureBlockAlarm AlarmStatus,
linkXpicRemTxOffAlarm AlarmStatus,
linkRemoteIduAlarmSynthesis AlarmStatus,
linkNotMatchingRadiosAlarm AlarmStatus,
linkConfigurationInProgress INTEGER,
linkXpd Integer32
}
linkPolIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the radio polarization. In XPIC radio link
identifies one of the polarizations."
::= {linkStatusEntry 1}
linkAcmRxProfile OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the ACM profile number in use in the radio Rx.
It is the linkAcmProfileId of linkAcmTable.
Label is linkAcmProfileLabel from linkAcmTable"
::= {linkStatusEntry 2}
linkAcmTxProfile OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the ACM profile number in use in the radio Tx.
It is the linkAcmProfileId of linkAcmTable.
Label is linkAcmProfileLabel from linkAcmTable"
::= {linkStatusEntry 3}
linkAcmRxProfileLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string used to describe current acm rx profile"
::= {linkStatusEntry 4}
linkAcmTxProfileLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string used to describe current acm tx profile"
::= {linkStatusEntry 5}
linkAcmRxModulation OBJECT-TYPE
SYNTAX BitsPerSymbol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the type of modulation of the Rx profile in use."
::= {linkStatusEntry 6}
linkAcmTxModulation OBJECT-TYPE
SYNTAX BitsPerSymbol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the type of modulation of the Tx profile in use."
::= {linkStatusEntry 7}
linkAcmRxCode OBJECT-TYPE
SYNTAX INTEGER {
unknown (0),
normal (1),
strong (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the type of codificator of the Rx profile in use."
::= {linkStatusEntry 8}
linkAcmTxCode OBJECT-TYPE
SYNTAX INTEGER {
unknown (0),
normal (1),
strong (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the type of codificator of the Tx profile in use."
::= {linkStatusEntry 9}
linkTxETHCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports (in Kbits/sec) the transmitted payload
capacity used by the Ethernet"
DEFVAL { 0 }
::= {linkStatusEntry 10}
linkRxETHCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports (in Kbits/sec) the received payload capacity
used by the Ethernet"
DEFVAL { 0 }
::= {linkStatusEntry 11}
linkTxTDMCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the capacity in kbit/sec reserved to TDM
tributaries in tx ACM profile."
DEFVAL { 0 }
::= {linkStatusEntry 12}
linkRxTDMCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the capacity in kbit/sec reserved to TDM
tributaries in rx ACM profile."
DEFVAL { 0 }
::= {linkStatusEntry 13}
linkRescueModulation OBJECT-TYPE
SYNTAX BitsPerSymbol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the modulation used when the remote terminal is
unreachable, ie traffic on radio link is down."
DEFVAL { bps4QAM }
::= {linkStatusEntry 14}
linkReducedCapacityAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The equipment works in reduced capacity"
::= {linkStatusEntry 15}
linkLinkTelemetryFailAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fail of link telemetry communication channel with associated
Severity"
::= {linkStatusEntry 16}
linkIdMismatchAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Identification Alarm with associated Severity"
::= {linkStatusEntry 17}
linkRadioEocAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fail of Radio Eoc link communication channel with associated
Severity"
::= {linkStatusEntry 18}
linkSetupMismatchAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local setup doesn't match the setup of remote terminal"
::= {linkStatusEntry 19}
linkRescueSetupAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The equipment is using the setup relative to the rescue modulation"
::= {linkStatusEntry 20}
linkXpicProcedureBlockAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Only for XPIC equipment configurations.
Equipment Controller XPIC procedure Alarm control with associated
Severity"
::= {linkStatusEntry 21}
linkXpicRemTxOffAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Only for XPIC equipment configurations.
Remote TX OFF command with associated Severity"
::= {linkStatusEntry 22}
linkRemoteIduAlarmSynthesis OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synthesis of the remote IDU alarms"
::= {linkStatusEntry 23}
linkNotMatchingRadiosAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Radios of the link does not have matched parameters."
::= {linkStatusEntry 24}
linkConfigurationInProgress OBJECT-TYPE
SYNTAX INTEGER {
cleared (1),
active (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link is being configured and the table linkSettingsTable is
not available for modifying parameters.
"
::= {linkStatusEntry 25}
linkXpd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Cross-Polarization Discrimination, in tenths of dB, is the
difference between the received signal power of the
co-polarized main beam, and it componemt received on the
cross-polarized signal.
This object shows an extimated value of the XPD performed by
the cross-polarization interference canceller (XPIC).
This means that the measure is reliable if:
- XPIC is on (linkType is radio2p0Xpic(4), or radio2p2XpicHS(5),
or radio2p2XpicFD(6))
- Alarm radioDemodulatorFailAlarm is cleared.
- XPD is not too high, since without cross-polar interference
the canceller is not able to works well. Basically, in this
condition, the extimated XPD is greater than the real one.
"
::= {linkStatusEntry 26}
--
------- End of linkStatusTable
------- Begin of linkTfcTable
--
linkTfcTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkTfcEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Transmitter Fail Check feature. In 1+1 HS configuration, the
radio terminal that doesn't receive signals on both receivers,
requests the remote transmitter switch.
This table was deprecated and replaced by linkTfcV2Table.
It is a view of the rows of the linkTfcV2Table with the same
linkIndex and linkPolIndex equal to 1, in order to ensure
compatibility with old SNMP managers.
"
::= {radioSystem 18}
linkTfcEntry OBJECT-TYPE
SYNTAX LinkTfcEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Radio link TFC entry."
INDEX {linkIndex}
::= {linkTfcTable 1}
LinkTfcEntry ::=
SEQUENCE {
linkTfcAction INTEGER,
linkTfcControl INTEGER,
linkTfcWatchWindow INTEGER,
linkTfcAlarmThreshold INTEGER,
linkTfcAlarm AlarmStatus,
linkTfcRowStatus RowStatus
}
linkTfcAction OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
reset (1)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"reset: to clear the forced switch generated by Trasmission Fail
Check algorithm (only if 1+1 configuration and ISO system)."
::= {linkTfcEntry 1}
linkTfcControl OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"It enables the Tx switch from remote equipment (only if 1+1
configuration and ISO system)."
DEFVAL {disable}
::= {linkTfcEntry 2}
linkTfcWatchWindow OBJECT-TYPE
SYNTAX INTEGER (1..300)
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Watch Window (in seconds) related to Trasmission Fail Check
algorithm (only if 1+1 configuration and ISO system)."
DEFVAL { 60 }
::= {linkTfcEntry 3}
linkTfcAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (1..60)
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Alarm Threshold (number of seconds with both remote RX in fail)
related to Trasmission Fail Check algorithm (only if 1+1
configuration and ISO system)."
DEFVAL { 10 }
::= {linkTfcEntry 4}
linkTfcAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Transmission switch alarm generated by Trasmission Fail Check
algorithm (only if 1+1 configuration and ISO system)."
::= {linkTfcEntry 5}
linkTfcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Status of this conceptual row in linkTfcTable."
::= {linkTfcEntry 6}
--
------- End of linkTfcTable
------- Begin of linkMaintTable
--
linkMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with commands for maintenance of radio link.
Objects in this table is not persistent. An Instance of this
table is created on creation of linkStatusEntry"
::= {radioSystem 19}
linkMaintEntry OBJECT-TYPE
SYNTAX LinkMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Radio link maintenance entry."
INDEX {linkIndex,
linkPolIndex}
::= {linkMaintTable 1}
LinkMaintEntry ::=
SEQUENCE {
linkBerStart INTEGER,
linkBaseBandLom INTEGER,
linkFadeMarginMeasure INTEGER,
linkXpicControlProcedureReset INTEGER
}
linkBerStart OBJECT-TYPE
SYNTAX INTEGER {
restart (1),
stop (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Stop, Start (resetting errors and counters) the pattern.
This item is linked to a manual operation (ManOpRecord) instance."
DEFVAL {stop}
::= {linkMaintEntry 1}
linkBaseBandLom OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to enable the IP packet forwarding towards modems.
This item is linked to a manual operation (ManOpRecord) instance."
DEFVAL {disable}
::= {linkMaintEntry 2}
linkFadeMarginMeasure OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Set by manager to start/stop fade margin measure.
This item is linked to a manual operation (ManOpRecord) instance.
This object is deprecated and replaced by fadeMarginMeasure.
"
DEFVAL { disable }
::= {linkMaintEntry 3}
linkXpicControlProcedureReset OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set by manager to reset the XPIC control procedure after a
blocking action."
DEFVAL {notActive}
::= {linkMaintEntry 4}
--
------- End of linkMaintTable
------- Begin of linkBerTable
--
linkBerTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkBerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with Command to estimate BER of radio equipment.
Every objects in this table is not persistent. An Instance of this
table is created on creation of linkStatusEntry"
::= {radioSystem 20}
linkBerEntry OBJECT-TYPE
SYNTAX LinkBerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Radio equipment BER estimate record."
INDEX {linkIndex,
linkPolIndex}
::= {linkBerTable 1}
LinkBerEntry ::=
SEQUENCE {
linkBerErrorCounterH Counter32,
linkBerErrorCounterL Counter32,
linkBerDataCounterH Counter32,
linkBerDataCounterL Counter32,
linkBerSyncLossAlarm AlarmStatus,
linkBerSyncLossAlarmCounter Integer32,
linkBerElapsedTime Integer32
}
linkBerErrorCounterH OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High 32 bit part of the 64 bit error counter. Bit 32-63."
::= {linkBerEntry 1}
linkBerErrorCounterL OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low 32 bit part of the 64 bit error counter. Bit 0-31."
::= {linkBerEntry 2}
linkBerDataCounterH OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High 32 bit part of the 64 bit data counter. Bit 32-63."
::= {linkBerEntry 3}
linkBerDataCounterL OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low 32 bit part of the 64 bit data counter. Bit 0-31."
::= {linkBerEntry 4}
linkBerSyncLossAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BER sync loss alarm."
::= {linkBerEntry 5}
linkBerSyncLossAlarmCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BER sync loss events counter."
::= {linkBerEntry 6}
linkBerElapsedTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BER measure elapsed time."
::= {linkBerEntry 7}
--
------- End of linkBerTable
------- Begin of linkAcmTable
--
linkAcmTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkAcmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with link records."
::= {radioSystem 21}
linkAcmEntry OBJECT-TYPE
SYNTAX LinkAcmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ACM entries."
INDEX {linkIndex, linkPolIndex, linkAcmProfileId}
::= {linkAcmTable 1}
LinkAcmEntry ::=
SEQUENCE {
linkAcmProfileId Integer32,
linkAcmProfileModulation BitsPerSymbol,
linkAcmProfileCode INTEGER,
linkAcmProfileCapacity Integer32,
linkAcmProfileLabel DisplayString,
linkAcmMaxTDMCapacity Integer32,
linkAcmPowerScaling Integer32,
linkAcmProfileEnable INTEGER,
linkAcmDownshiftThreshold Integer32,
linkAcmUpshiftThreshold Integer32,
linkAcmActiveProfile INTEGER,
linkAcmTDMCapacity Integer32,
linkAcmETHCapacity Integer32,
linkAcmAtpcRxPowerScaling Integer32,
linkAcmPowerRange Integer32
}
linkAcmProfileId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the profile number for the radio selected
by the object linkAcmId."
::= {linkAcmEntry 1}
linkAcmProfileModulation OBJECT-TYPE
SYNTAX BitsPerSymbol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the modulation of the profile."
::= {linkAcmEntry 2}
linkAcmProfileCode OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
strong (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the type of codificator of the profile."
::= {linkAcmEntry 3}
linkAcmProfileCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to contain total capacity of profile
(in kbits/sec)."
::= {linkAcmEntry 4}
linkAcmProfileLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string used to assign a name to profile."
::= {linkAcmEntry 5}
linkAcmProfileEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is used to contain if the use of this profile is
enabled or disabled"
DEFVAL {enable}
::= {linkAcmEntry 6}
linkAcmMaxTDMCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object reports the maximum capacity that can
be assigned to the TDM traffic.
The capacity is specified in number of E1 (2Mbit/s).
This object has been superseded by linkE1vsSTM1CapacityTable.
"
DEFVAL {0}
::= {linkAcmEntry 7}
linkAcmPowerScaling OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object contains the difference (in eighth of dB) between the
TX power at this profile modulation and the TX power at the
reference modulation. The power scaling value is achieved from the
table linkPtxProfileTable.
This object is deprecated: see combinedRadioPowerScalingTable."
::= {linkAcmEntry 8}
linkAcmDownshiftThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is used to contain the downshift threshold in dB/10."
::= {linkAcmEntry 9}
linkAcmUpshiftThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is used to contain the upshift threshold in dB/10."
::= {linkAcmEntry 10}
linkAcmActiveProfile OBJECT-TYPE
SYNTAX INTEGER {
cleared (1),
activeRx (2),
activeTx (3),
activeBoth (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to contain the active status of this profile.
The value of the object is related to linkAcmRxProfile
and linkAcmTxProfile of the LinkStatusEntry."
DEFVAL {cleared}
::= {linkAcmEntry 11}
linkAcmTDMCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports current TDM capacity (in kbits/sec)
of the profile."
::= {linkAcmEntry 12}
linkAcmETHCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports current ETH capacity (in Kbits/sec) of
the profile."
::= {linkAcmEntry 13}
linkAcmAtpcRxPowerScaling OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object contains the difference (in eighth of dB) between the
ATPC RX level thresholds at this profile modulation and the ATPC
RX level thresholds at the upper modulation.
This object is deprecated: see combinedRadioPowerScalingTable."
::= {linkAcmEntry 14}
linkAcmPowerRange OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object contains (in dB) the current value of ATPC range.
This object is deprecated: see combinedRadioPowerScalingTable."
::= {linkAcmEntry 15}
--
------- End of linkAcmTable
------- Begin of linkProTable
--
linkProTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkProEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A list of protection link entries.
This table was deprecated and replaced by linkProV2Table.
It is a view of the rows of the linkProV2Table with the same
linkIndex and linkPolIndex equal to 1, in order to ensure
compatibility with old SNMP managers
"
::= {radioSystem 22}
linkProEntry OBJECT-TYPE
SYNTAX LinkProEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry containing management information applicable to a
protected link.
"
INDEX {linkIndex}
::= {linkProTable 1}
LinkProEntry ::=
SEQUENCE {
linkProProtectionTxChIdx Integer32,
linkProProtectionRxChIdx Integer32,
linkProTxWtrTime INTEGER,
linkProRxWtrTime INTEGER,
linkProTxSwitchedChIdx Integer32,
linkProRxSwitchedChIdx Integer32,
linkProTxRevertive INTEGER,
linkProRxRevertive INTEGER,
linkProExtraTraffic INTEGER,
linkProRowStatus RowStatus
}
linkProProtectionTxChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object identifies the tx protection channel
of a protected link. This object is not applicable
in case of not-revertive protection. For N+1 links
a value different from zero must be set.
"
DEFVAL {0}
::= {linkProEntry 1}
linkProProtectionRxChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object identifies the rx protection channel
of a protected link. This object is not applicable
in case of not-revertive protection. For N+1 links
a value different from zero must be set.
"
DEFVAL {0}
::= {linkProEntry 2}
linkProTxWtrTime OBJECT-TYPE
SYNTAX INTEGER (0..12)
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"It defines the Wait Time (in minutes) to Restore in transmission
when revertive protection is enabled. Zero value means no switch.
If switch is not supported or protection is not revertive,
a value different from zero cannot be set.
"
DEFVAL {0}
::= {linkProEntry 3}
linkProRxWtrTime OBJECT-TYPE
SYNTAX INTEGER (0..12)
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"It defines the Wait Time (in minutes) to Restore in reception when
revertive protection is enabled. Zero value means no switch.
If switch is not supported or protection is not revertive,
a value different from zero cannot be set.
"
DEFVAL {0}
::= {linkProEntry 4}
linkProTxSwitchedChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object reports the index of tx channel switched to protection.
This object is applicable only for N+1 protection schema.
"
DEFVAL {0}
::= {linkProEntry 5}
linkProRxSwitchedChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object reports the index of rx channel switched to protection.
This object is applicable only for N+1 protection schema.
"
DEFVAL {0}
::= {linkProEntry 6}
linkProTxRevertive OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"It defines if tx protection is revertive or not revertive.
In case of N+1 protection, protection is always revertive.
"
DEFVAL {disable}
::= {linkProEntry 7}
linkProRxRevertive OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"It defines if rx protection is revertive or not revertive.
In case of N+1 protection, protection is always revertive.
"
DEFVAL {disable}
::= {linkProEntry 8}
linkProExtraTraffic OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object enables or disables the transfer of extra traffic
on the protection channel in a N+1 link. This object must be
set to disabled in case of architectures different for N+1.
"
DEFVAL {disable}
::= {linkProEntry 9}
linkProRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Status of this conceptual row in linkProTable.
"
::= {linkProEntry 10}
--
------- End of linkProTable
------- Begin of linkProMaintTable
--
linkProMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkProMaintEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A list of maintenance commands for protected links.
A row in this table is added on creation of a row
in linkProTable.
This table was deprecated and replaced by linkProMaintV2Table.
It is a view of the rows of the linkProMaintV2Table with the same
linkIndex and linkPolIndex equal to 1, in order to ensure
compatibility with old SNMP managers
"
::= {radioSystem 23}
linkProMaintEntry OBJECT-TYPE
SYNTAX LinkProMaintEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry containing maintenance commands applicable to a
protected link.
"
INDEX {linkIndex}
::= {linkProMaintTable 1}
LinkProMaintEntry ::=
SEQUENCE {
linkProMaintTxLockout INTEGER,
linkProMaintRxLockout INTEGER,
linkProMaintTxForced Integer32,
linkProMaintRxForced Integer32,
linkProMaintTxWtrReset INTEGER,
linkProMaintRxWtrReset INTEGER
}
linkProMaintTxLockout OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Command to enable/disable tx lockout. This object
is applicable only in case of N+1 protections.
"
DEFVAL {disable}
::= {linkProMaintEntry 1}
linkProMaintRxLockout OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Command to enable/disable rx lockout. This object
is applicable only in case of N+1 protections.
"
DEFVAL {disable}
::= {linkProMaintEntry 2}
linkProMaintTxForced OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Command to force switch to a given
transmission channel. Zero value means no
switch.
"
DEFVAL {0}
::= {linkProMaintEntry 3}
linkProMaintRxForced OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Command to force switch to a given
receiving channel. Zero value means no
switch.
"
DEFVAL {0}
::= {linkProMaintEntry 4}
linkProMaintTxWtrReset OBJECT-TYPE
SYNTAX INTEGER {
notActive (1),
on (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Clear wait time to restore making the revertive
path immediately available.
"
DEFVAL {notActive}
::= {linkProMaintEntry 5}
linkProMaintRxWtrReset OBJECT-TYPE
SYNTAX INTEGER {
notActive (1),
on (2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Clear wait time to restore making the revertive
path immediately available.
"
DEFVAL {notActive}
::= {linkProMaintEntry 6}
--
------- End of linkProMaintTable
------- Begin of linkCapabilitiesTable
--
linkCapabilitiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkCapabilitiesEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table with RadioCapabilities entries: there is an entry for each
linkTable row.
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios.
In 1+1 FD radio link, managers have to know the capabilities
of each channel. As such, this table is declared deprecated and
replaced by combinedRadioCapabilitiesTable."
::= {radioSystem 24}
linkCapabilitiesEntry OBJECT-TYPE
SYNTAX LinkCapabilitiesEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"LinkCapabilities entry."
INDEX {linkIndex}
::= {linkCapabilitiesTable 1}
LinkCapabilitiesEntry ::=
SEQUENCE {
linkCapabilitiesCapability RadioCapability,
linkCapabilitiesTxMinFrequency Integer32,
linkCapabilitiesTxMaxFrequency Integer32,
linkCapabilitiesStepFrequency Integer32,
linkCapabilitiesMinPtxNominalValue Integer32,
linkCapabilitiesMaxPtxNominalValue Integer32,
linkCapabilitiesExtendedMinPwr Integer32
}
linkCapabilitiesCapability OBJECT-TYPE
SYNTAX RadioCapability
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Bit map to describe the radio features."
::= {linkCapabilitiesEntry 1}
linkCapabilitiesTxMinFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Minimum of available channel frequency in KHz."
::= {linkCapabilitiesEntry 2}
linkCapabilitiesTxMaxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Maximum of available channel frequency in KHz."
::= {linkCapabilitiesEntry 3}
linkCapabilitiesStepFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Minimum frequency step in KHz."
::= {linkCapabilitiesEntry 4}
linkCapabilitiesMinPtxNominalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Minimum nominal Ptx in dBm."
::= {linkCapabilitiesEntry 5}
linkCapabilitiesMaxPtxNominalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Maximum nominal Ptx in dBm."
::= {linkCapabilitiesEntry 6}
linkCapabilitiesExtendedMinPwr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Minimum extended Ptx power for fade margin."
::= {linkCapabilitiesEntry 7}
--
------- End of linkCapabilitiesTable
------- Begin of linkFrequencyTable
--
linkFrequencyTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkFreqEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Availables channels for selected channel spacing and modulation
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios.
In 1+1 FD radio link, managers have to know the allowable
frequencies of each channel. As such, this table is declared
deprecated and replaced by combinedRadioFrequencyTable."
::= {radioSystem 25}
linkFreqTabEntry OBJECT-TYPE
SYNTAX LinkFreqEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"LinkFreqTab record."
INDEX {linkIndex, linkFreqChannelId}
::= {linkFrequencyTable 1}
LinkFreqEntry ::=
SEQUENCE {
linkFreqChannelId Integer32,
linkFreqChannelNum Integer32,
linkFreqValue Integer32
}
linkFreqChannelId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Index of the table"
::= {linkFreqTabEntry 1}
linkFreqChannelNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Available channel number."
::= {linkFreqTabEntry 2}
linkFreqValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Frequency related to linkFreqChannelNum."
::= {linkFreqTabEntry 3}
--
------- End of linkFrequencyTable
------- Begin of linkDuplexFrequencyTable
--
linkDuplexFrequencyTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkDuplexFreqEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table with available duplex frequencies. Duplex frequency is
the absolute value of difference between RX and TX frequency.
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios.
In 1+1 FD radio link, managers have to know the allowable
duplex frequencies of each channel. As such, this table is declared
deprecated and replaced by combinedRadioDuplexFrequencyTable."
::= {radioSystem 26}
linkDuplexFreqEntry OBJECT-TYPE
SYNTAX LinkDuplexFreqEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Duplex Frequency entry. For each available duplex frequency"
INDEX {linkIndex, linkDuplexFreqId}
::= {linkDuplexFrequencyTable 1}
LinkDuplexFreqEntry ::=
SEQUENCE {
linkDuplexFreqId Integer32,
linkDuplexFreqValue Integer32
}
linkDuplexFreqId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Index of the table."
::= {linkDuplexFreqEntry 1}
linkDuplexFreqValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Duplex frequency in KHz."
::= {linkDuplexFreqEntry 2}
--
------- End of linkDuplexFrequencyTable
------- Begin of linkModulationTable
--
linkModulationTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of modulation related to channel spacing.
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios.
"
::= {radioSystem 27}
linkModulationEntry OBJECT-TYPE
SYNTAX LinkModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"linkModulation record."
INDEX {linkIndex, linkChannelSpacing}
::= {linkModulationTable 1}
LinkModulationEntry ::=
SEQUENCE {
linkChannelSpacing ChannelSpacing,
linkModulationMap ModulationMap,
linkRefModulationMap ModulationMap
}
linkChannelSpacing OBJECT-TYPE
SYNTAX ChannelSpacing
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the channel spacing."
::= {linkModulationEntry 1}
linkModulationMap OBJECT-TYPE
SYNTAX ModulationMap
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"List of modulation in the linkChanSpacing"
::= {linkModulationEntry 2}
linkRefModulationMap OBJECT-TYPE
SYNTAX ModulationMap
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"List of modulations that can be selected as reference
in the linkChanSpacingId"
::= {linkModulationEntry 3}
--
------- End of linkModulationTable
------- Begin of linkChCapabilitiesTable
--
combinedRadioCapabilitiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF CombinedRadioCapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with RadioCapabilities entries: there is an entry for each
radioSettingTable row.
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios belonging to the link.
In 1+1 FD radio link, managers have to know the allowable
duplex frequencies of each channel. As such, this table is declared
deprecated and replaced by combinedRadioCapabilitiesTable."
::= {radioSystem 28}
combinedRadioCapabilitiesEntry OBJECT-TYPE
SYNTAX CombinedRadioCapabilitiesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"combinedRadioCapabilities entry."
INDEX {radioSettingsIndex}
::= {combinedRadioCapabilitiesTable 1}
CombinedRadioCapabilitiesEntry ::=
SEQUENCE {
combinedRadioCapabilitiesCapability RadioCapability,
combinedRadioCapabilitiesTxMinFrequency Integer32,
combinedRadioCapabilitiesTxMaxFrequency Integer32,
combinedRadioCapabilitiesStepFrequency Integer32,
combinedRadioCapabilitiesMinPtxNominalValue Integer32,
combinedRadioCapabilitiesMaxPtxNominalValue Integer32,
combinedRadioCapabilitiesExtendedMinPwr Integer32
}
combinedRadioCapabilitiesCapability OBJECT-TYPE
SYNTAX RadioCapability
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit map to describe the radio features."
::= {combinedRadioCapabilitiesEntry 1}
combinedRadioCapabilitiesTxMinFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum of available channel frequency in KHz."
::= {combinedRadioCapabilitiesEntry 2}
combinedRadioCapabilitiesTxMaxFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum of available channel frequency in KHz."
::= {combinedRadioCapabilitiesEntry 3}
combinedRadioCapabilitiesStepFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum frequency step in KHz."
::= {combinedRadioCapabilitiesEntry 4}
combinedRadioCapabilitiesMinPtxNominalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum nominal Ptx in dBm."
::= {combinedRadioCapabilitiesEntry 5}
combinedRadioCapabilitiesMaxPtxNominalValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum nominal Ptx in dBm."
::= {combinedRadioCapabilitiesEntry 6}
combinedRadioCapabilitiesExtendedMinPwr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum extended Ptx power for fade margin."
::= {combinedRadioCapabilitiesEntry 7}
--
------- End of combinedRadioCapabilitiesTable
------- Begin of combinedRadioFrequencyTable
--
combinedRadioFrequencyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CombinedRadioFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Availables channels for selected channel spacing and modulation
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios."
::= {radioSystem 29}
combinedRadioFreqTabEntry OBJECT-TYPE
SYNTAX CombinedRadioFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"combinedRadioFreqTab record."
INDEX {radioSettingsIndex, combinedRadioFreqChannelId}
::= {combinedRadioFrequencyTable 1}
CombinedRadioFreqEntry ::=
SEQUENCE {
combinedRadioFreqChannelId Integer32,
combinedRadioFreqChannelNum Integer32,
combinedRadioFreqValue Integer32
}
combinedRadioFreqChannelId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table"
::= {combinedRadioFreqTabEntry 1}
combinedRadioFreqChannelNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Available channel number."
::= {combinedRadioFreqTabEntry 2}
combinedRadioFreqValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency related to combinedRadioFreqChannelNum."
::= {combinedRadioFreqTabEntry 3}
--
------- End of combinedRadioFrequencyTable
------- Begin of combinedRadioDuplexFrequencyTable
--
combinedRadioDuplexFrequencyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CombinedRadioDuplexFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with available duplex frequencies. Duplex frequency is
the absolute value of difference between RX and TX frequency.
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios."
::= {radioSystem 30}
combinedRadioDuplexFreqEntry OBJECT-TYPE
SYNTAX CombinedRadioDuplexFreqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Duplex Frequency entry. There is an entry for each available
duplex frequency."
INDEX {radioSettingsIndex, combinedRadioDuplexFreqId}
::= {combinedRadioDuplexFrequencyTable 1}
CombinedRadioDuplexFreqEntry ::=
SEQUENCE {
combinedRadioDuplexFreqId Integer32,
combinedRadioDuplexFreqValue Integer32
}
combinedRadioDuplexFreqId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index of the table."
::= {combinedRadioDuplexFreqEntry 1}
combinedRadioDuplexFreqValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duplex frequency in KHz."
::= {combinedRadioDuplexFreqEntry 2}
--
------- End of combinedRadioDuplexFrequencyTable
------- Begin of combinedRadioPowerScalingTable
--
combinedRadioPowerScalingTable OBJECT-TYPE
SYNTAX SEQUENCE OF CombinedRadioPowerScalingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of modulation related to channel spacing.
In 1+1 HS and XPIC radio links, this table contains only values
supported by both radios."
::= {radioSystem 31}
combinedRadioPowerScalingEntry OBJECT-TYPE
SYNTAX CombinedRadioPowerScalingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"radioPowerScaling record."
INDEX {radioSettingsIndex, linkAcmProfileId}
::= {combinedRadioPowerScalingTable 1}
CombinedRadioPowerScalingEntry ::=
SEQUENCE {
combinedRadioPowerScaling Integer32,
combinedRadioAtpcRxPowerScaling Integer32,
combinedRadioPowerRange Integer32
}
combinedRadioPowerScaling OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the difference (in eighth of dB) between the
TX power at this profile modulation and the TX power at the
reference modulation. The power scaling value is achieved from the
table linkPtxProfileTable."
::= {combinedRadioPowerScalingEntry 1}
combinedRadioAtpcRxPowerScaling OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the difference (in eighth of dB) between the
ATPC RX level thresholds at this profile modulation and the ATPC
RX level thresholds at the upper modulation."
::= {combinedRadioPowerScalingEntry 2}
combinedRadioPowerRange OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains (in dB) the current value of ATPC range."
::= {combinedRadioPowerScalingEntry 3}
--
------- End of radioPowerScalingTable
------- Begin of stm1BulkSettingsTable
--
stm1BulkMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF Stm1BulkMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with entries containing stm-1 bulk transport parameters
for a particular link.
For each link are present as many rows as the STM-1 that the link
can carry in bulk mode.
"
::= {radioSystem 32}
stm1BulkMappingEntry OBJECT-TYPE
SYNTAX Stm1BulkMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An row in stm1BulkSettingsTable.
"
INDEX {linkIndex, stm1BulkPolIndex, stm1BulkChanIndex}
::= {stm1BulkMappingTable 1}
Stm1BulkMappingEntry ::=
SEQUENCE {
stm1BulkPolIndex Integer32,
stm1BulkChanIndex Integer32,
stm1BulkChannel Stm1IndexOrZero
}
stm1BulkPolIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Polarization index.
"
::= {stm1BulkMappingEntry 1}
stm1BulkChanIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"STM-1 channel index.
The range of this object is from 1 to N, where N is the number
of STM-1 that a link can carry in bulk mode.
"
::= {stm1BulkMappingEntry 2}
stm1BulkChannel OBJECT-TYPE
SYNTAX Stm1IndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Index of the stm-1 in stm1Table.
The SNMP agent will accept only index of a STM-1 present in
stm1Table with stm1Structure set to opaque(4).
"
DEFVAL {0}
::= {stm1BulkMappingEntry 3}
--
------- End of stm1BulkSettingsTable
------- Begin of linkE1vsSTM1CapacityTable
--
linkE1vsSTM1CapacityTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkE1vsSTM1CapacityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with entries containing the E1 cpacity according to the
tributaries STM-1 configured to be carried in bulk mode.
"
::= {radioSystem 33}
linkE1vsSTM1CapacityEntry OBJECT-TYPE
SYNTAX LinkE1vsSTM1CapacityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An row in linkE1vsSTM1CapacityTable.
"
INDEX {linkIndex, linkAcmProfileId, linkE1vsSTM1CapacityStm1}
::= {linkE1vsSTM1CapacityTable 1}
LinkE1vsSTM1CapacityEntry ::=
SEQUENCE {
linkE1vsSTM1CapacityStm1 Integer32,
linkE1vsSTM1CapacityE1 Integer32
}
linkE1vsSTM1CapacityStm1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Number of tributaries STM-1 configured to be transported in
bulk mode.
"
::= {linkE1vsSTM1CapacityEntry 1 }
linkE1vsSTM1CapacityE1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of E1 that can be carried by this profile according to the
the tributaries STM-1 carried in bulk mode.
"
::= {linkE1vsSTM1CapacityEntry 2}
--
------- End of linkE1vsSTM1CapacityTable
------- Begin of linkTfcV2Table
--
linkTfcV2Table OBJECT-TYPE
SYNTAX SEQUENCE OF LinkTfcV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transmitter Fail Check feature. In 1+1 HS configuration, the
radio terminal that doesn't receive signals on both receivers,
requests the remote transmitter switch."
::= {radioSystem 34}
linkTfcV2Entry OBJECT-TYPE
SYNTAX LinkTfcV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Radio link TFC entry."
INDEX {linkIndex, linkPolIndex}
::= {linkTfcV2Table 1}
LinkTfcV2Entry ::=
SEQUENCE {
linkTfcV2Action INTEGER,
linkTfcV2Control INTEGER,
linkTfcV2WatchWindow INTEGER,
linkTfcV2AlarmThreshold INTEGER,
linkTfcV2Alarm AlarmStatus,
linkTfcV2RowStatus RowStatus
}
linkTfcV2Action OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
reset (1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"reset: to clear the forced switch generated by Trasmission Fail
Check algorithm (only if 1+1 configuration and ISO system)."
::= {linkTfcV2Entry 1}
linkTfcV2Control OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"It enables the Tx switch from remote equipment (only if 1+1
configuration and ISO system)."
DEFVAL {disable}
::= {linkTfcV2Entry 2}
linkTfcV2WatchWindow OBJECT-TYPE
SYNTAX INTEGER (1..300)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Watch Window (in seconds) related to Trasmission Fail Check
algorithm (only if 1+1 configuration and ISO system)."
DEFVAL { 60 }
::= {linkTfcV2Entry 3}
linkTfcV2AlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (1..60)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Alarm Threshold (number of seconds with both remote RX in fail)
related to Trasmission Fail Check algorithm (only if 1+1
configuration and ISO system)."
DEFVAL { 10 }
::= {linkTfcV2Entry 4}
linkTfcV2Alarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmission switch alarm generated by Trasmission Fail Check
algorithm (only if 1+1 configuration and ISO system)."
::= {linkTfcV2Entry 5}
linkTfcV2RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this conceptual row in linkTfcV2Table."
::= {linkTfcV2Entry 6}
--
------- End of linkTfcV2Table
------- Begin of linkProV2Table
--
linkProV2Table OBJECT-TYPE
SYNTAX SEQUENCE OF LinkProV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of protection link entries.
"
::= {radioSystem 35}
linkProV2Entry OBJECT-TYPE
SYNTAX LinkProV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
protected link.
"
INDEX {linkIndex, linkPolIndex}
::= {linkProV2Table 1}
LinkProV2Entry ::=
SEQUENCE {
linkProV2ProtectionTxChIdx Integer32,
linkProV2ProtectionRxChIdx Integer32,
linkProV2TxWtrTime INTEGER,
linkProV2RxWtrTime INTEGER,
linkProV2TxSwitchedChIdx Integer32,
linkProV2RxSwitchedChIdx Integer32,
linkProV2TxRevertive INTEGER,
linkProV2RxRevertive INTEGER,
linkProV2ExtraTraffic INTEGER,
linkProV2RowStatus RowStatus
}
linkProV2ProtectionTxChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the tx protection channel
of a protected link. This object is not applicable
in case of not-revertive protection. For N+1 links
a value different from zero must be set.
"
DEFVAL {0}
::= {linkProV2Entry 1}
linkProV2ProtectionRxChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the rx protection channel
of a protected link. This object is not applicable
in case of not-revertive protection. For N+1 links
a value different from zero must be set.
"
DEFVAL {0}
::= {linkProV2Entry 2}
linkProV2TxWtrTime OBJECT-TYPE
SYNTAX INTEGER (0..12)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"It defines the Wait Time (in minutes) to Restore in transmission
when revertive protection is enabled. Zero value means no switch.
If switch is not supported or protection is not revertive,
a value different from zero cannot be set.
"
DEFVAL {0}
::= {linkProV2Entry 3}
linkProV2RxWtrTime OBJECT-TYPE
SYNTAX INTEGER (0..12)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"It defines the Wait Time (in minutes) to Restore in reception when
revertive protection is enabled. Zero value means no switch.
If switch is not supported or protection is not revertive,
a value different from zero cannot be set.
"
DEFVAL {0}
::= {linkProV2Entry 4}
linkProV2TxSwitchedChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the index of tx channel switched to protection.
This object is applicable only for N+1 protection schema.
"
DEFVAL {0}
::= {linkProV2Entry 5}
linkProV2RxSwitchedChIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the index of rx channel switched to protection.
This object is applicable only for N+1 protection schema.
"
DEFVAL {0}
::= {linkProV2Entry 6}
linkProV2TxRevertive OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"It defines if tx protection is revertive or not revertive.
In case of N+1 protection, protection is always revertive.
"
DEFVAL {disable}
::= {linkProV2Entry 7}
linkProV2RxRevertive OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"It defines if rx protection is revertive or not revertive.
In case of N+1 protection, protection is always revertive.
"
DEFVAL {disable}
::= {linkProV2Entry 8}
linkProV2ExtraTraffic OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables or disables the transfer of extra traffic
on the protection channel in a N+1 link. This object must be
set to disabled in case of architectures different for N+1.
"
DEFVAL {disable}
::= {linkProV2Entry 9}
linkProV2RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this conceptual row in linkProV2Table.
"
::= {linkProV2Entry 10}
--
------- End of linkProV2Table
------- Begin of linkProMaintV2Table
--
linkProMaintV2Table OBJECT-TYPE
SYNTAX SEQUENCE OF LinkProMaintV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of maintenance commands for protected links.
A row in this table is added on creation of a row
in linkProV2Table.
"
::= {radioSystem 36}
linkProMaintV2Entry OBJECT-TYPE
SYNTAX LinkProMaintV2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing maintenance commands applicable to a
protected link.
"
INDEX {linkIndex, linkPolIndex}
::= {linkProMaintV2Table 1}
LinkProMaintV2Entry ::=
SEQUENCE {
linkProMaintV2TxLockout INTEGER,
linkProMaintV2RxLockout INTEGER,
linkProMaintV2TxForced Integer32,
linkProMaintV2RxForced Integer32,
linkProMaintV2TxWtrReset INTEGER,
linkProMaintV2RxWtrReset INTEGER
}
linkProMaintV2TxLockout OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command to enable/disable tx lockout. This object
is applicable only in case of N+1 protections.
"
DEFVAL {disable}
::= {linkProMaintV2Entry 1}
linkProMaintV2RxLockout OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command to enable/disable rx lockout. This object
is applicable only in case of N+1 protections.
"
DEFVAL {disable}
::= {linkProMaintV2Entry 2}
linkProMaintV2TxForced OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command to force switch to a given
transmission channel. Zero value means no
switch.
"
DEFVAL {0}
::= {linkProMaintV2Entry 3}
linkProMaintV2RxForced OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command to force switch to a given
receiving channel. Zero value means no
switch.
"
DEFVAL {0}
::= {linkProMaintV2Entry 4}
linkProMaintV2TxWtrReset OBJECT-TYPE
SYNTAX INTEGER {
notActive (1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear wait time to restore making the revertive
path immediately available.
"
DEFVAL {notActive}
::= {linkProMaintV2Entry 5}
linkProMaintV2RxWtrReset OBJECT-TYPE
SYNTAX INTEGER {
notActive (1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear wait time to restore making the revertive
path immediately available.
"
DEFVAL {notActive}
::= {linkProMaintV2Entry 6}
--
------- End of linkProMaintV2Table
------- Begin of sspTable
--
sspTable OBJECT-TYPE
SYNTAX SEQUENCE OF SspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of operative and administrative set of parameters.
This table holds three row for every link (and its polarizations)
configured in the NE:
1) administative parameters of local NE
2) operative parameters of local NE
3) administative parameters of remote NE
"
::= {radioSystem 37}
sspEntry OBJECT-TYPE
SYNTAX SspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing SSP relevant parameters.
"
INDEX {linkIndex, linkPolIndex, sspParameterType}
::= {sspTable 1}
SspEntry ::=
SEQUENCE {
sspParameterType INTEGER,
sspLinkBandwidth INTEGER,
sspLinkModulation INTEGER,
sspLinkAcmEngineEnable INTEGER,
sspLinkTxUpperProfile INTEGER,
sspLinkTxLowerProfile INTEGER,
sspLinkSynchSetupProtocolEnable INTEGER,
sspLinkProfilesSetSelection INTEGER,
sspTdmE1Channel Integer32,
sspTdmStm1Channel Integer32
}
sspParameterType OBJECT-TYPE
SYNTAX INTEGER {
localAdminStatus (1),
localOperStatus (2),
remoteAdminStatus (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies what parameters are for.
"
::= {sspEntry 1}
sspLinkBandwidth OBJECT-TYPE
SYNTAX INTEGER {
sspBw3p5Mhz (0),
sspBw7MHz (1),
sspBw14MHz (2),
sspBw28MHz (3),
sspBw56MHz (4),
sspBw10MHz (5),
sspBw20MHz (6),
sspBw30MHz (7),
sspBw40MHz (8),
sspBw50MHz (9),
sspBw112Mhz (10),
sspBw250Mhz (11),
sspBw500Mhz (12),
sspBw750Mhz (13),
sspBw1Ghz (14),
sspBw60MHz (15),
sspBw80MHz (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Bandwidth (channel spacing).
"
::= {sspEntry 2}
sspLinkModulation OBJECT-TYPE
SYNTAX INTEGER{
sspModBPSK (1),
sspMod4QAM (2),
sspMod8PSK (3),
sspMod16QAM (4),
sspMod32QAM (5),
sspMod64QAM (6),
sspMod128QAM (7),
sspMod256QAM (8),
sspMod512QAM (9),
sspMod1024QAM (10),
sspMod2048QAM (11),
sspMod4096QAM (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link reference modulation.
"
::= {sspEntry 3}
sspLinkAcmEngineEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to enable/disable the ACM engine.
"
DEFVAL { disable }
::= {sspEntry 4}
sspLinkTxUpperProfile OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object (and linkTxLowerProfile object) is used to
restrict the TX profile range when ACM is enabled.
"
::= {sspEntry 5}
sspLinkTxLowerProfile OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object (and linkTxUpperProfile object) is used to
restrict the TX profile range when ACM is enabled.
"
::= {sspEntry 6}
sspLinkSynchSetupProtocolEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synchronization Setup Protocol (SSP) control.
"
::= {sspEntry 7}
sspLinkProfilesSetSelection OBJECT-TYPE
SYNTAX INTEGER {
highThroughput (1),
highGain (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selection of the working profile set between high gain
(max robustness) profile set and high throughput (max
capacity) profile set. The set of profiles high gain
features a greater robustness against to the set of
profiles high throughput.
For radio systems that do not have more sets of profiles,
this object becomes read only and its reading shows the
only one set of profiles supported.
"
::= {sspEntry 8}
sspTdmE1Channel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of E1 channels. This object is used to define the capacity
of E1 tributaries assigned to a given radio link. The capacity is
changed in steps of E1 (2Mbit/s).
"
::= {sspEntry 9}
sspTdmStm1Channel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of STM-1 channels transported in bulk mode.
"
::= {sspEntry 10}
--
------- End of sspTable
------- Begin of radioLoopCapabilityTable
--
radioLoopCapabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioLoopCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows which group a radio loop belongs to.
Radios with the same group number (identifier) close loop
simultaneously.
"
::= {radioSystem 38}
radioLoopCapabilityEntry OBJECT-TYPE
SYNTAX RadioLoopCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a group identifier for each radio loop type.
"
INDEX {radioIndex}
::= {radioLoopCapabilityTable 1}
RadioLoopCapabilityEntry ::=
SEQUENCE {
radioLoopRfGroup Integer32,
radioLoopIqGroup Integer32,
radioLoopBaseBandGroup Integer32
}
radioLoopRfGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group to which the radio RF loop belong to.
"
::= {radioLoopCapabilityEntry 1}
radioLoopIqGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group to which the radio IQ loop belong to.
"
::= {radioLoopCapabilityEntry 2}
radioLoopBaseBandGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group to which the radio base loop belong to.
"
::= {radioLoopCapabilityEntry 3}
--
------- End of radioLoopCapabilityTable
------- Begin of radioRxThresholdTable
--
radioRxBerThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadioRxBerThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shows the nominal and measured values of RX power
at a bit error rate (BER) equal to 10e-6.
"
::= {radioSystem 39}
radioRxBerThresholdEntry OBJECT-TYPE
SYNTAX RadioRxBerThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing the RX power thresholds.
"
INDEX {radioIndex}
::= {radioRxBerThresholdTable 1}
RadioRxBerThresholdEntry ::=
SEQUENCE {
radioRxBerThresholdStatus INTEGER,
radioNominalRxBerThreshold Integer32,
radioMeasuredRxBerThreshold Integer32
}
radioRxBerThresholdStatus OBJECT-TYPE
SYNTAX INTEGER {
nonValid (1),
valid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows whether the following objects are significant.
"
::= {radioRxBerThresholdEntry 1}
radioNominalRxBerThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal value of RX power @ BER equal to 10e-6
"
::= {radioRxBerThresholdEntry 2}
radioMeasuredRxBerThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured value of RX power @ BER equal to 10e-6.
"
::= {radioRxBerThresholdEntry 3}
--
------- End of radioRxThresholdTable
radioRemDemodulatorFailAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioRemDemodulatorFailAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 50}
radioRxActiveStatusTrapNotification OBJECT-TYPE
SYNTAX INTEGER {
trapDisable (1),
trapEnable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disables (statusTrapEnable or statusTrapDisable) the trap
generation on status change event for radioRxActivestatus"
DEFVAL{ trapEnable }
::= {radioSystem 51}
radioTxActiveStatusTrapNotification OBJECT-TYPE
SYNTAX INTEGER {
trapDisable (1),
trapEnable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the radioTxActivestatus and
enable/disable the trap generation on status change event."
DEFVAL{ trapEnable }
::= {radioSystem 52}
radioCableOpenAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioCableOpen
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 53}
radioCableShortAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioCableShort
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 54}
radioInvalidFrequencyAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioInvalidFrequencyAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 55}
radioBaseBandRxAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioBaseBandRxAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 56}
radioModulatorFailAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioModulatorFailAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 57}
radioDemodulatorFailAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioDemodulatorFailAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 58}
radioRxPowerLowAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioRxPowerLowAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 59}
radioTxPowerLowAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioTxPowerLowAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 60}
radioVcoFailAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioVcoFailAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 61}
radioRxIFAgcAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioRxIFAgcAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 62}
radioTxIFAgcAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioTxIFAgcAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 63}
radioIduOduCommunicationAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the radioIduOduCommunicationAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 64}
radioOduIduCommunicationAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the radioOduIduCommunicationAlarm
and enable/disable the trap generation on status change event."
DEFVAL {warningTrapEnable}
::= {radioSystem 65}
radioLocalOduAlarmSynthesisSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the radioLocalOduAlarmSynthesis
and enable/disable the trap generation on status change event."
DEFVAL {statusTrapDisable}
::= {radioSystem 66}
radioRemoteOduAlarmSynthesisSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the radioRemoteOduAlarmSynthesis
and enable/disable the trap generation on status change event."
DEFVAL {statusTrapDisable}
::= {radioSystem 67}
radioConfigMismatchAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the radioConfigMismatchAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 68}
radioPrxHysteresisValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the delta value associated to the radioPrx before
having a new trap generation (radioPtxChange TRAP).
The zero value is not allowed."
DEFVAL {3}
::= {radioSystem 69}
radioPtxHysteresisValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the delta value associated to the radioPtx before
having a new trap generation (radioPtxChange TRAP).
The zero value is not allowed."
DEFVAL {3}
::= {radioSystem 70}
radioPrxHysteresisValueTrapNotification OBJECT-TYPE
SYNTAX INTEGER {
trapDisable (1),
trapEnable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the Rx change trap generation on status change
event."
DEFVAL {trapEnable}
::= {radioSystem 71}
radioPtxHysteresisValueTrapNotification OBJECT-TYPE
SYNTAX INTEGER {
trapDisable (1),
trapEnable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the Tx change trap generation on status change
event."
DEFVAL {trapEnable}
::= {radioSystem 72}
radioRxQualityLowAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the radioRxQualityLowAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 73}
radioRxQualityWarningAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the radioRxQualityWarningAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 74}
linkReducedCapacityAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkReducedCapacityAlarm
and enable/disable the trap generation on status change event."
DEFVAL {warningTrapEnable}
::= {radioSystem 75}
linkLinkTelemetryFailAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkLinkTelemetryFailAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 76}
linkIdMismatchAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkIdMismatchAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 77}
linkRadioEocAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkRadioEocAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 78}
linkSetupMismatchAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkSetupMismatchAlarm
and enable/disable the trap generation on status change event."
DEFVAL {warningTrapEnable}
::= {radioSystem 79}
linkRescueSetupAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkRescueSetupAlarm
and enable/disable the trap generation on status change event."
DEFVAL {criticalTrapEnable}
::= {radioSystem 80}
linkXpicProcedureBlockAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkXpicProcedureBlockAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 81}
linkXpicRemTxOffAlarmAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkXpicRemTxOffAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 82}
linkLocalIduAlarmSynthesis OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synthesis of the local IDU alarms"
::= {radioSystem 83}
linkLocalIduAlarmSynthesisSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkLocalIduAlarmSynthesis
and enable/disable the trap generation on status change event."
DEFVAL{ statusTrapDisable }
::= {radioSystem 84}
linkRemoteIduAlarmSynthesisSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkLocalIduAlarmSynthesis
and enable/disable the trap generation on status change event."
DEFVAL{ statusTrapDisable }
::= {radioSystem 85}
linkTfcAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkTfcV2Alarm (linkTfcAlarm)
and enable/disable the trap generation on status change event."
DEFVAL { minorTrapEnable }
::= {radioSystem 86}
linkBerSyncLossAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkBerSyncLossAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 87}
linkNotMatchingRadiosAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the linkNotMatchingRadiosAlarm
and enable/disable the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {radioSystem 88}
channelSpacingSelection OBJECT-TYPE
SYNTAX BITS {
etsi (0),
fcc (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"his object selects which channel spacings the radio link has to
support:
- etsi: Compliant with European Telecommunication Standards
Institute
- fcc: Compliant with Federal Communications Commission
"
DEFVAL { { etsi, fcc } }
::= {radioSystem 89}
fadeMarginMeasure OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set by manager to start/stop fade margin measure.
This item is linked to a manual operation (ManOpRecord) instance."
DEFVAL { disable }
::= {radioSystem 90}
linkConfigurationInProgressTrapNotification OBJECT-TYPE
SYNTAX INTEGER {
trapDisable (1),
trapEnable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disables (statusTrapEnable or statusTrapDisable) the trap
generation on status change event for linkConfigurationInProgress"
DEFVAL{ trapEnable }
::= {radioSystem 91}
-----------------------
-- This MIB module generates the following TRAPs:
-----------------------
radioPrxChange NOTIFICATION-TYPE
OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPrx}
STATUS current
DESCRIPTION
"This event is generated when radioPrx is changed, in
modulus, more than radioPtxHysteresisValue from last TRAP.
The data passed with the event are:
1) equipIpSnmpAgentAddress - agent IP address
2) radioIndex - branch index
3) radioName - user assinged name
4) radioPrx - PRX value"
::= { alarmTrap 8001 }
radioPtxChange NOTIFICATION-TYPE
OBJECTS {equipIpSnmpAgentAddress, radioIndex, radioSettingsLabel, radioPtx}
STATUS current
DESCRIPTION
"This event is generated when radioPtx is changed, in
modulus, more than radioPtxHysteresisValue from last TRAP.
The data passed with the event are:
1) equipIpSnmpAgentAddress - agent IP address
2) radioIndex - branch index
3) radioName - user assigned name
4) radioPtx - PTX value"
::= { alarmTrap 8002 }
------ End group -----------------------------------------------------------------
---------------------------------- End -------------------------------------
END