238 lines
8.0 KiB
Plaintext
238 lines
8.0 KiB
Plaintext
|
-- SmartOptics Enterprise Specific TC MIB.
|
||
|
--
|
||
|
-- Copyright (c) 2011, SmartOptics
|
||
|
-- All rights reserved
|
||
|
--
|
||
|
|
||
|
MSERIES-TC DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY
|
||
|
FROM SNMPv2-SMI
|
||
|
TEXTUAL-CONVENTION
|
||
|
FROM SNMPv2-TC
|
||
|
mseries
|
||
|
FROM MSERIES-MIB;
|
||
|
|
||
|
|
||
|
smartTcMIB MODULE-IDENTITY
|
||
|
LAST-UPDATED "201402121327Z"
|
||
|
ORGANIZATION "SmartOptics"
|
||
|
CONTACT-INFO "http://www.smartoptics.com"
|
||
|
DESCRIPTION
|
||
|
"This is the enterprise specific TC MIB for SmartOptics M-Series"
|
||
|
REVISION "201402121327Z"
|
||
|
DESCRIPTION
|
||
|
"Added PortStatus and PortMode."
|
||
|
|
||
|
REVISION "201310151341Z"
|
||
|
DESCRIPTION
|
||
|
"Descriptions updated."
|
||
|
REVISION "201112050000Z"
|
||
|
DESCRIPTION
|
||
|
"Initial revision."
|
||
|
|
||
|
::= { mseries 5 }
|
||
|
|
||
|
--
|
||
|
-- definitions of the textual convetions
|
||
|
--
|
||
|
|
||
|
AlarmPerceivedSeverity ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Alarm severity as defined in ITU-T X.733."
|
||
|
SYNTAX INTEGER {
|
||
|
cleared (1),
|
||
|
indeterminate (2),
|
||
|
critical (3),
|
||
|
major (4),
|
||
|
minor (5),
|
||
|
warning (6)
|
||
|
}
|
||
|
|
||
|
AlarmNotificationType ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Type of alarm as defined in ITU-T X.733."
|
||
|
SYNTAX INTEGER {
|
||
|
undefined (0),
|
||
|
other (1),
|
||
|
communicationsAlarm (2),
|
||
|
qualityOfServiceAlarm (3),
|
||
|
processingErrorAlarm (4),
|
||
|
equipmentAlarm (5),
|
||
|
environmental (6),
|
||
|
integrityViolation (7),
|
||
|
operationalViolation (8),
|
||
|
physicalViolation(9),
|
||
|
securityServiceOrMechanismViloation (10),
|
||
|
timeDomainViolation (11)
|
||
|
}
|
||
|
|
||
|
AlarmProbableCause ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Alarm probable cause as defined in ITU-T X.733."
|
||
|
SYNTAX INTEGER {
|
||
|
undefined (0),
|
||
|
adapterError (1), -- Equipment
|
||
|
applicationSubsystemFailure (2), -- Processing
|
||
|
bandwidthReduced (3), -- Quality of service
|
||
|
callEstablishmentError (4), -- Communications
|
||
|
communicationsProtocolError (5), -- Communications
|
||
|
communicationsSubsystemFailure (6), -- Communications
|
||
|
configurationOrCustomizationError (7), -- Processing
|
||
|
congestion (8), -- Quality of service
|
||
|
corruptData (9), -- Processing
|
||
|
cpuCyclesLimitExceeded (10), -- Processing
|
||
|
dTEdCEInterfaceError (11), -- Communications
|
||
|
datasetOrModemError (12), -- Equipment
|
||
|
degradedSignal (13), -- Communications
|
||
|
enclosureDoorOpen (14), -- Environmental
|
||
|
equipmentMalfunction (15), -- Equipment
|
||
|
excessiveVibration (16), -- Environmental
|
||
|
fileError (17), -- Processing
|
||
|
fireDetected (18), -- Environmental
|
||
|
floodDetected (19), -- Environmental
|
||
|
framingError (20), -- Communications
|
||
|
heatingOrVentilationOrCoolingSystemProblem (21), -- Environmental
|
||
|
humidityUnacceptable (22), -- Environmental
|
||
|
inputDeviceError (23), -- Equipment
|
||
|
inputOutputDeviceError (24), -- Equipment
|
||
|
lANError (25), -- Communications
|
||
|
leakDetected (26), -- Environmental
|
||
|
localNodeTransmissionError (27), -- Communications
|
||
|
lossOfFrame (28), -- Communications
|
||
|
lossOfSignal (29), -- Communications
|
||
|
materialSupplyExhausted (30), -- Environmental
|
||
|
multiplexerProblem (31), -- Equipment
|
||
|
outOfMemory (32), -- Processing
|
||
|
outputDeviceError (33), -- Equipment
|
||
|
performanceDegraded (34), -- Quality of service
|
||
|
powerProblem (35), -- Equipment
|
||
|
pressureUnacceptable (36), -- Environmental
|
||
|
processorProblem (37), -- Equipment
|
||
|
pumpFailure (38), -- Environmental
|
||
|
queueSizeExceeded (39), -- Quality of service
|
||
|
receiveFailure (40), -- Equipment
|
||
|
receiverFailure (41), -- Equipment
|
||
|
remoteNodeTransmissionError (42), -- Communications
|
||
|
resourceAtOrNearingCapacity (43), -- Quality of service
|
||
|
responseTimeExcessive (44), -- Quality of service
|
||
|
retransmissionRateExcessive (45), -- Quality of service
|
||
|
softwareProgramError (46), -- Processing
|
||
|
softwareError (47), -- Processing
|
||
|
softwareProgramAbnormallyTerminated (48), -- Processing
|
||
|
storageCapacityProblem (49), -- Processing
|
||
|
temperatureUnacceptable (50), -- Environmental
|
||
|
thresholdCrossed (51), -- Quality of service
|
||
|
timingProblem (52), -- Equipment
|
||
|
toxicLeakDetected (53), -- Environmental
|
||
|
transmitFailure (54), -- Equipment
|
||
|
transmitterFailure (55), -- Equipment
|
||
|
underlyingResourceUnavailable (56), -- Processing
|
||
|
versionMismatch (57) } -- Processing
|
||
|
|
||
|
|
||
|
UnitType ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit type in the M-Series.
|
||
|
|
||
|
nmb - Network Management Board. The controlling
|
||
|
board of the M-Series.
|
||
|
|
||
|
psu1 - The Power Supply in slot 1 of the M-Series.
|
||
|
|
||
|
psu2 - The Power Supply in slot 2 of the M-Series.
|
||
|
|
||
|
fan - The Fan of the M-Series.
|
||
|
|
||
|
system - The chassis.
|
||
|
|
||
|
slaveNmb - Network Management Board of the Cascading system.
|
||
|
|
||
|
slavePsu1 - The Power Supply in slot 1 of the Cascading M-Series.
|
||
|
|
||
|
slavePsu2 - The Power Supply in slot 2 of the Cascading M-Series.
|
||
|
|
||
|
slaveFan - The Fan of the Cascading M-Series."
|
||
|
SYNTAX INTEGER {
|
||
|
nmb (1),
|
||
|
psu1 (2),
|
||
|
psu2 (3),
|
||
|
fan (4),
|
||
|
system (5),
|
||
|
slaveNmb (6),
|
||
|
slavePsu1 (7),
|
||
|
slavePsu2 (8),
|
||
|
slaveFan (9)
|
||
|
}
|
||
|
|
||
|
PortType ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Port direction.
|
||
|
|
||
|
rx - The port direction is receiving(Rx).
|
||
|
|
||
|
tx - The port direction is transmitting(Tx).
|
||
|
|
||
|
biDi - The port direction is both transmitting and receiving."
|
||
|
SYNTAX INTEGER {
|
||
|
rx (1),
|
||
|
tx (2),
|
||
|
biDi (3)
|
||
|
}
|
||
|
|
||
|
PortStatus ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The operational state for a port.
|
||
|
|
||
|
idle - The port is not activated
|
||
|
|
||
|
down - The port traffic is lost.
|
||
|
|
||
|
up - There is traffic on the port.
|
||
|
|
||
|
high - The port got to high power.
|
||
|
|
||
|
low - The port got to low power.
|
||
|
|
||
|
eyeSafety - The Line Tx port is in Eye Safety Mode.
|
||
|
This means that either the connector on the
|
||
|
Line Tx port is not inserted or that you have
|
||
|
too strong reflection from the line fiber.
|
||
|
|
||
|
cd - Channel detected.
|
||
|
|
||
|
ncd - No channel detected."
|
||
|
SYNTAX INTEGER {
|
||
|
idle (1),
|
||
|
down (2),
|
||
|
up (3),
|
||
|
high (4),
|
||
|
low (5),
|
||
|
eyeSafety (6),
|
||
|
cd (7),
|
||
|
ncd (8) }
|
||
|
|
||
|
PortMode ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Port Mode.
|
||
|
|
||
|
normal - The port is active. Alarms are not suppressed.
|
||
|
|
||
|
service - the port is in Service Mode. Alarms are
|
||
|
beeing suppressed. When service is ready the
|
||
|
Port Mode should be set back to normal."
|
||
|
SYNTAX INTEGER {
|
||
|
normal (1),
|
||
|
service (2)
|
||
|
}
|
||
|
|
||
|
END
|