mibs/MIBS/smartoptics/MSERIES-TC
2023-12-05 12:25:34 +01:00

238 lines
8.0 KiB
Plaintext

-- SmartOptics Enterprise Specific TC MIB.
--
-- Copyright (c) 2011, SmartOptics
-- All rights reserved
--
MSERIES-TC DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
mseries
FROM MSERIES-MIB;
smartTcMIB MODULE-IDENTITY
LAST-UPDATED "201402121327Z"
ORGANIZATION "SmartOptics"
CONTACT-INFO "http://www.smartoptics.com"
DESCRIPTION
"This is the enterprise specific TC MIB for SmartOptics M-Series"
REVISION "201402121327Z"
DESCRIPTION
"Added PortStatus and PortMode."
REVISION "201310151341Z"
DESCRIPTION
"Descriptions updated."
REVISION "201112050000Z"
DESCRIPTION
"Initial revision."
::= { mseries 5 }
--
-- definitions of the textual convetions
--
AlarmPerceivedSeverity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Alarm severity as defined in ITU-T X.733."
SYNTAX INTEGER {
cleared (1),
indeterminate (2),
critical (3),
major (4),
minor (5),
warning (6)
}
AlarmNotificationType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Type of alarm as defined in ITU-T X.733."
SYNTAX INTEGER {
undefined (0),
other (1),
communicationsAlarm (2),
qualityOfServiceAlarm (3),
processingErrorAlarm (4),
equipmentAlarm (5),
environmental (6),
integrityViolation (7),
operationalViolation (8),
physicalViolation(9),
securityServiceOrMechanismViloation (10),
timeDomainViolation (11)
}
AlarmProbableCause ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Alarm probable cause as defined in ITU-T X.733."
SYNTAX INTEGER {
undefined (0),
adapterError (1), -- Equipment
applicationSubsystemFailure (2), -- Processing
bandwidthReduced (3), -- Quality of service
callEstablishmentError (4), -- Communications
communicationsProtocolError (5), -- Communications
communicationsSubsystemFailure (6), -- Communications
configurationOrCustomizationError (7), -- Processing
congestion (8), -- Quality of service
corruptData (9), -- Processing
cpuCyclesLimitExceeded (10), -- Processing
dTEdCEInterfaceError (11), -- Communications
datasetOrModemError (12), -- Equipment
degradedSignal (13), -- Communications
enclosureDoorOpen (14), -- Environmental
equipmentMalfunction (15), -- Equipment
excessiveVibration (16), -- Environmental
fileError (17), -- Processing
fireDetected (18), -- Environmental
floodDetected (19), -- Environmental
framingError (20), -- Communications
heatingOrVentilationOrCoolingSystemProblem (21), -- Environmental
humidityUnacceptable (22), -- Environmental
inputDeviceError (23), -- Equipment
inputOutputDeviceError (24), -- Equipment
lANError (25), -- Communications
leakDetected (26), -- Environmental
localNodeTransmissionError (27), -- Communications
lossOfFrame (28), -- Communications
lossOfSignal (29), -- Communications
materialSupplyExhausted (30), -- Environmental
multiplexerProblem (31), -- Equipment
outOfMemory (32), -- Processing
outputDeviceError (33), -- Equipment
performanceDegraded (34), -- Quality of service
powerProblem (35), -- Equipment
pressureUnacceptable (36), -- Environmental
processorProblem (37), -- Equipment
pumpFailure (38), -- Environmental
queueSizeExceeded (39), -- Quality of service
receiveFailure (40), -- Equipment
receiverFailure (41), -- Equipment
remoteNodeTransmissionError (42), -- Communications
resourceAtOrNearingCapacity (43), -- Quality of service
responseTimeExcessive (44), -- Quality of service
retransmissionRateExcessive (45), -- Quality of service
softwareProgramError (46), -- Processing
softwareError (47), -- Processing
softwareProgramAbnormallyTerminated (48), -- Processing
storageCapacityProblem (49), -- Processing
temperatureUnacceptable (50), -- Environmental
thresholdCrossed (51), -- Quality of service
timingProblem (52), -- Equipment
toxicLeakDetected (53), -- Environmental
transmitFailure (54), -- Equipment
transmitterFailure (55), -- Equipment
underlyingResourceUnavailable (56), -- Processing
versionMismatch (57) } -- Processing
UnitType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The unit type in the M-Series.
nmb - Network Management Board. The controlling
board of the M-Series.
psu1 - The Power Supply in slot 1 of the M-Series.
psu2 - The Power Supply in slot 2 of the M-Series.
fan - The Fan of the M-Series.
system - The chassis.
slaveNmb - Network Management Board of the Cascading system.
slavePsu1 - The Power Supply in slot 1 of the Cascading M-Series.
slavePsu2 - The Power Supply in slot 2 of the Cascading M-Series.
slaveFan - The Fan of the Cascading M-Series."
SYNTAX INTEGER {
nmb (1),
psu1 (2),
psu2 (3),
fan (4),
system (5),
slaveNmb (6),
slavePsu1 (7),
slavePsu2 (8),
slaveFan (9)
}
PortType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Port direction.
rx - The port direction is receiving(Rx).
tx - The port direction is transmitting(Tx).
biDi - The port direction is both transmitting and receiving."
SYNTAX INTEGER {
rx (1),
tx (2),
biDi (3)
}
PortStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The operational state for a port.
idle - The port is not activated
down - The port traffic is lost.
up - There is traffic on the port.
high - The port got to high power.
low - The port got to low power.
eyeSafety - The Line Tx port is in Eye Safety Mode.
This means that either the connector on the
Line Tx port is not inserted or that you have
too strong reflection from the line fiber.
cd - Channel detected.
ncd - No channel detected."
SYNTAX INTEGER {
idle (1),
down (2),
up (3),
high (4),
low (5),
eyeSafety (6),
cd (7),
ncd (8) }
PortMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Port Mode.
normal - The port is active. Alarms are not suppressed.
service - the port is in Service Mode. Alarms are
beeing suppressed. When service is ready the
Port Mode should be set back to normal."
SYNTAX INTEGER {
normal (1),
service (2)
}
END