-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-LMM-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-LMM-MIB DEFINITIONS ::= BEGIN
IMPORTS
ifIndex
FROM IF-MIB
switch
FROM PRVT-SWITCH-MIB
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
FROM SNMPv2-SMI
TruthValue
FROM SNMPv2-TC;
prvtLmmMIB MODULE-IDENTITY
LAST-UPDATED "201110110000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Initial version. This MIB will configure laser monitoring"
REVISION "201110110000Z"
DESCRIPTION
"Initial release"
::= { switch 172 }
prvtLmmNotifications OBJECT IDENTIFIER
::= { prvtLmmMIB 0 }
prvtLmmObjects OBJECT IDENTIFIER
::= { prvtLmmMIB 1 }
prvtLmmShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable laser monitoring"
::= { prvtLmmObjects 1 }
prvtLmmDebug OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable laser monitoring"
::= { prvtLmmObjects 2 }
prvtLmmPeriod OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the monitoring interval (sec)."
::= { prvtLmmObjects 3 }
prvtLmmTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable sending SNMP traps when thresholds are crossed"
::= { prvtLmmObjects 4 }
prvtLmmLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable alert notification logging when thresholds are crossed"
::= { prvtLmmObjects 5 }
prvtLmmLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable LED-alert notifications when thresholds are crossed"
::= { prvtLmmObjects 6 }
prvtLmmTemperatureHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-128..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the low threshold value for global temperature (-128 up to 128).
prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
::= { prvtLmmObjects 7 }
prvtLmmTemperatureLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-128..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the low threshold value for global temperature (-128 up to 128).
prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
::= { prvtLmmObjects 8 }
prvtLmmRxPowerLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the low threshold value for global RX-power (-40 up to 8)
prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
::= { prvtLmmObjects 9 }
prvtLmmRxPowerHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the high threshold value for global RX-power (-40 up to 8)
prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
::= { prvtLmmObjects 10 }
prvtLmmTxPowerLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the low threshold value for global RX-power (-40 up to 8)
prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
::= { prvtLmmObjects 11 }
prvtLmmTxPowerHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the high threshold value for global RX-power (-40 up to 8)
prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
::= { prvtLmmObjects 12 }
prvtLmmInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtLmmInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Lmm configuration per ethernet port"
::= { prvtLmmObjects 13 }
prvtLmmInterfaceEntry OBJECT-TYPE
SYNTAX PrvtLmmInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Stack table entry"
INDEX { ifIndex }
::= { prvtLmmInterfaceTable 1 }
PrvtLmmInterfaceEntry ::= SEQUENCE {
prvtLmmInterfaceShutdown TruthValue,
prvtLmmInterfaceTempLowThreshold Integer32,
prvtLmmInterfaceTempHighThreshold Integer32,
prvtLmmInterfaceTempValue Integer32,
prvtLmmInterfaceTempThresholdLo Integer32,
prvtLmmInterfaceTempThresholdHi Integer32,
prvtLmmInterfaceTempTestState TruthValue,
prvtLmmInterfaceRxPowerLowThreshold Integer32,
prvtLmmInterfaceRxPowerHighThreshold Integer32,
prvtLmmInterfaceRxPowerValue Integer32,
prvtLmmInterfaceRxPowerThresholdRxLo Integer32,
prvtLmmInterfaceRxPowerThresholdRxHi Integer32,
prvtLmmInterfaceRxPowerTestState TruthValue,
prvtLmmInterfaceTxPowerLowThreshold Integer32,
prvtLmmInterfaceTxPowerHighThreshold Integer32,
prvtLmmInterfaceTxPowerValue Integer32,
prvtLmmInterfaceTxPowerThresholdTxLo Integer32,
prvtLmmInterfaceTxPowerThresholdTxHi Integer32,
prvtLmmInterfaceTxPowerTestState TruthValue,
prvtLmmInterfaceOperStatus TruthValue
}
prvtLmmInterfaceShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable laser monitoring on port"
::= { prvtLmmInterfaceEntry 1 }
prvtLmmInterfaceTempLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-128..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the low threshold value for port temperature"
::= { prvtLmmInterfaceEntry 2 }
prvtLmmInterfaceTempHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-128..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the high threshold value for port temperature.
Value of prvtLmmInterfaceTempHighThreshold must be greater than
prvtLmmInterfaceTempLowThreshold"
::= { prvtLmmInterfaceEntry 3 }
prvtLmmInterfaceTempValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display laser Temperature current value"
::= { prvtLmmInterfaceEntry 4 }
prvtLmmInterfaceTempThresholdLo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The thresholds read from hardware or set by user"
::= { prvtLmmInterfaceEntry 5 }
prvtLmmInterfaceTempThresholdHi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The thresholds read from hardware or set by user"
::= { prvtLmmInterfaceEntry 6 }
prvtLmmInterfaceTempTestState OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state test"
::= { prvtLmmInterfaceEntry 7 }
prvtLmmInterfaceRxPowerLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the low threshold value for port RX-power."
::= { prvtLmmInterfaceEntry 8 }
prvtLmmInterfaceRxPowerHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the high threshold value for port RX-power.
Value of prvtLmmInterfaceRxPowerHighThreshold must be greater than
prvtLmmInterfaceRxPowerLowThreshold"
::= { prvtLmmInterfaceEntry 9 }
prvtLmmInterfaceRxPowerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display laser Rx Power current value"
::= { prvtLmmInterfaceEntry 10 }
prvtLmmInterfaceRxPowerThresholdRxLo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The thresholds read from hardware or set by user"
::= { prvtLmmInterfaceEntry 11 }
prvtLmmInterfaceRxPowerThresholdRxHi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The thresholds read from hardware or set by user"
::= { prvtLmmInterfaceEntry 12 }
prvtLmmInterfaceRxPowerTestState OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state test"
::= { prvtLmmInterfaceEntry 13 }
prvtLmmInterfaceTxPowerLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the low threshold value for port TX-power"
::= { prvtLmmInterfaceEntry 14 }
prvtLmmInterfaceTxPowerHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the high threshold value for port TX-power
Value of prvtLmmInterfaceTxPowerHighThreshold must be greater than
prvtLmmInterfaceTxPowerLowThreshold"
::= { prvtLmmInterfaceEntry 15 }
prvtLmmInterfaceTxPowerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display laser Tx Power current value"
::= { prvtLmmInterfaceEntry 16 }
prvtLmmInterfaceTxPowerThresholdTxLo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The thresholds read from hardware or set by user"
::= { prvtLmmInterfaceEntry 17 }
prvtLmmInterfaceTxPowerThresholdTxHi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The thresholds read from hardware or set by user"
::= { prvtLmmInterfaceEntry 18 }
prvtLmmInterfaceTxPowerTestState OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state test"
::= { prvtLmmInterfaceEntry 19 }
prvtLmmInterfaceOperStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status"
::= { prvtLmmInterfaceEntry 20 }
prvtLmmTemperatureThresholdCrossed NOTIFICATION-TYPE
OBJECTS { prvtLmmInterfaceTempValue,
prvtLmmInterfaceTempThresholdHi,
prvtLmmInterfaceTempThresholdLo }
STATUS current
DESCRIPTION
"The prvtLmmTemperatureThresholdCrossed shall be generated
when prvtLmmInterfaceTempValue rises above prvtLmmInterfaceTempThresholdHi
or falls below prvtLmmInterfaceTempThresholdLo. Also the
notification shall be generated when prvtLmmInterfaceTempValue
returns to the normal range between prvtLmmInterfaceTempThresholdHi
and prvtLmmInterfaceTempThresholdLo."
::= { prvtLmmNotifications 1 }
prvtLmmTxPowerThresholdCrossed NOTIFICATION-TYPE
OBJECTS { prvtLmmInterfaceTxPowerValue,
prvtLmmInterfaceTxPowerThresholdTxHi,
prvtLmmInterfaceTxPowerThresholdTxLo }
STATUS current
DESCRIPTION
"The prvtLmmTxPowerThresholdCrossed shall be generated
when prvtLmmInterfaceTxPowerValue rises above prvtLmmInterfaceTxPowerThresholdTxHi
or falls below prvtLmmInterfaceTxPowerThresholdTxLo. Also the
notification shall be generated when prvtLmmInterfaceTxPowerValue
returns to the normal range between prvtLmmInterfaceTxPowerThresholdTxHi
and prvtLmmInterfaceTxPowerThresholdTxLo."
::= { prvtLmmNotifications 2 }
prvtLmmRxPowerThresholdCrossed NOTIFICATION-TYPE
OBJECTS { prvtLmmInterfaceRxPowerValue,
prvtLmmInterfaceRxPowerThresholdRxHi,
prvtLmmInterfaceRxPowerThresholdRxLo }
STATUS current
DESCRIPTION
"The prvtLmmRxPowerThresholdCrossed shall be generated
when prvtLmmInterfaceRxPowerValue rises above prvtLmmInterfaceRxPowerThresholdRxHi
or falls below prvtLmmInterfaceRxPowerThresholdRxLo. Also the
notification shall be generated when prvtLmmInterfaceRxPowerValue
returns to the normal range between prvtLmmInterfaceRxPowerThresholdRxHi
and prvtLmmInterfaceRxPowerThresholdRxLo."
::= { prvtLmmNotifications 3 }
END -- end of module PRVT-LMM-MIB.