427 lines
14 KiB
Plaintext
427 lines
14 KiB
Plaintext
-- *********************************************************************
|
|
-- **
|
|
-- ** BATM Advanced Communications.
|
|
-- **
|
|
-- *********************************************************************
|
|
-- ** Filename: PRVT-LMM-MIB.mib
|
|
-- ** Project: T-Metro Switches.
|
|
-- ** Purpose: Private MIB
|
|
-- *********************************************************************
|
|
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
|
|
-- WARNING:
|
|
--
|
|
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
|
--
|
|
-- This file is the property of BATM Advanced Communications and contains
|
|
-- proprietary and confidential information. This file is made
|
|
-- available to authorized BATM customers on the express
|
|
-- condition that neither it, nor any of the information contained
|
|
-- therein, shall be disclosed to third parties or be used for any
|
|
-- purpose other than to replace, modify or upgrade firmware and/or
|
|
-- software components of BATM manufactured equipment within the
|
|
-- authorized customer's network, and that such transfer be
|
|
-- completed in accordance with the instructions provided by
|
|
-- BATM. Any other use is strictly prohibited.
|
|
--
|
|
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
|
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
|
|
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
|
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
|
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
|
--
|
|
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
|
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
|
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
|
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
|
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
|
|
PRVT-LMM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
ifIndex
|
|
FROM IF-MIB
|
|
switch
|
|
FROM PRVT-SWITCH-MIB
|
|
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
TruthValue
|
|
FROM SNMPv2-TC;
|
|
|
|
prvtLmmMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201110110000Z"
|
|
ORGANIZATION
|
|
"BATM Advanced Communication"
|
|
CONTACT-INFO
|
|
"BATM/Telco Systems Support team
|
|
Email:
|
|
For North America: techsupport@telco.com
|
|
For North Europe: support@batm.de, info@batm.de
|
|
For the rest of the world: techsupport@telco.com"
|
|
DESCRIPTION
|
|
"Initial version. This MIB will configure laser monitoring"
|
|
REVISION "201110110000Z"
|
|
DESCRIPTION
|
|
"Initial release"
|
|
::= { switch 172 }
|
|
|
|
|
|
prvtLmmNotifications OBJECT IDENTIFIER
|
|
::= { prvtLmmMIB 0 }
|
|
|
|
prvtLmmObjects OBJECT IDENTIFIER
|
|
::= { prvtLmmMIB 1 }
|
|
|
|
prvtLmmShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable laser monitoring"
|
|
::= { prvtLmmObjects 1 }
|
|
|
|
prvtLmmDebug OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable laser monitoring"
|
|
::= { prvtLmmObjects 2 }
|
|
|
|
prvtLmmPeriod OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the monitoring interval (sec)."
|
|
::= { prvtLmmObjects 3 }
|
|
|
|
prvtLmmTrap OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable sending SNMP traps when thresholds are crossed"
|
|
::= { prvtLmmObjects 4 }
|
|
|
|
prvtLmmLog OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable alert notification logging when thresholds are crossed"
|
|
::= { prvtLmmObjects 5 }
|
|
|
|
prvtLmmLed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable LED-alert notifications when thresholds are crossed"
|
|
::= { prvtLmmObjects 6 }
|
|
|
|
prvtLmmTemperatureHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..128)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the low threshold value for global temperature (-128 up to 128).
|
|
prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
|
|
::= { prvtLmmObjects 7 }
|
|
|
|
prvtLmmTemperatureLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..128)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the low threshold value for global temperature (-128 up to 128).
|
|
prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold"
|
|
::= { prvtLmmObjects 8 }
|
|
|
|
prvtLmmRxPowerLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the low threshold value for global RX-power (-40 up to 8)
|
|
prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
|
|
::= { prvtLmmObjects 9 }
|
|
|
|
prvtLmmRxPowerHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the high threshold value for global RX-power (-40 up to 8)
|
|
prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold"
|
|
::= { prvtLmmObjects 10 }
|
|
|
|
prvtLmmTxPowerLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the low threshold value for global RX-power (-40 up to 8)
|
|
prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
|
|
::= { prvtLmmObjects 11 }
|
|
|
|
prvtLmmTxPowerHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the high threshold value for global RX-power (-40 up to 8)
|
|
prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold"
|
|
::= { prvtLmmObjects 12 }
|
|
|
|
prvtLmmInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrvtLmmInterfaceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lmm configuration per ethernet port"
|
|
::= { prvtLmmObjects 13 }
|
|
|
|
prvtLmmInterfaceEntry OBJECT-TYPE
|
|
SYNTAX PrvtLmmInterfaceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Stack table entry"
|
|
INDEX { ifIndex }
|
|
::= { prvtLmmInterfaceTable 1 }
|
|
|
|
PrvtLmmInterfaceEntry ::= SEQUENCE {
|
|
prvtLmmInterfaceShutdown TruthValue,
|
|
prvtLmmInterfaceTempLowThreshold Integer32,
|
|
prvtLmmInterfaceTempHighThreshold Integer32,
|
|
prvtLmmInterfaceTempValue Integer32,
|
|
prvtLmmInterfaceTempThresholdLo Integer32,
|
|
prvtLmmInterfaceTempThresholdHi Integer32,
|
|
prvtLmmInterfaceTempTestState TruthValue,
|
|
prvtLmmInterfaceRxPowerLowThreshold Integer32,
|
|
prvtLmmInterfaceRxPowerHighThreshold Integer32,
|
|
prvtLmmInterfaceRxPowerValue Integer32,
|
|
prvtLmmInterfaceRxPowerThresholdRxLo Integer32,
|
|
prvtLmmInterfaceRxPowerThresholdRxHi Integer32,
|
|
prvtLmmInterfaceRxPowerTestState TruthValue,
|
|
prvtLmmInterfaceTxPowerLowThreshold Integer32,
|
|
prvtLmmInterfaceTxPowerHighThreshold Integer32,
|
|
prvtLmmInterfaceTxPowerValue Integer32,
|
|
prvtLmmInterfaceTxPowerThresholdTxLo Integer32,
|
|
prvtLmmInterfaceTxPowerThresholdTxHi Integer32,
|
|
prvtLmmInterfaceTxPowerTestState TruthValue,
|
|
prvtLmmInterfaceOperStatus TruthValue
|
|
}
|
|
|
|
prvtLmmInterfaceShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable laser monitoring on port"
|
|
::= { prvtLmmInterfaceEntry 1 }
|
|
|
|
prvtLmmInterfaceTempLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..128)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the low threshold value for port temperature"
|
|
::= { prvtLmmInterfaceEntry 2 }
|
|
|
|
prvtLmmInterfaceTempHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..128)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the high threshold value for port temperature.
|
|
Value of prvtLmmInterfaceTempHighThreshold must be greater than
|
|
prvtLmmInterfaceTempLowThreshold"
|
|
::= { prvtLmmInterfaceEntry 3 }
|
|
|
|
prvtLmmInterfaceTempValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Display laser Temperature current value"
|
|
::= { prvtLmmInterfaceEntry 4 }
|
|
|
|
prvtLmmInterfaceTempThresholdLo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The thresholds read from hardware or set by user"
|
|
::= { prvtLmmInterfaceEntry 5 }
|
|
|
|
prvtLmmInterfaceTempThresholdHi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The thresholds read from hardware or set by user"
|
|
::= { prvtLmmInterfaceEntry 6 }
|
|
|
|
prvtLmmInterfaceTempTestState OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state test"
|
|
::= { prvtLmmInterfaceEntry 7 }
|
|
|
|
prvtLmmInterfaceRxPowerLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the low threshold value for port RX-power."
|
|
::= { prvtLmmInterfaceEntry 8 }
|
|
|
|
prvtLmmInterfaceRxPowerHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the high threshold value for port RX-power.
|
|
Value of prvtLmmInterfaceRxPowerHighThreshold must be greater than
|
|
prvtLmmInterfaceRxPowerLowThreshold"
|
|
::= { prvtLmmInterfaceEntry 9 }
|
|
|
|
prvtLmmInterfaceRxPowerValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Display laser Rx Power current value"
|
|
::= { prvtLmmInterfaceEntry 10 }
|
|
|
|
prvtLmmInterfaceRxPowerThresholdRxLo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The thresholds read from hardware or set by user"
|
|
::= { prvtLmmInterfaceEntry 11 }
|
|
|
|
prvtLmmInterfaceRxPowerThresholdRxHi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The thresholds read from hardware or set by user"
|
|
::= { prvtLmmInterfaceEntry 12 }
|
|
|
|
prvtLmmInterfaceRxPowerTestState OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state test"
|
|
::= { prvtLmmInterfaceEntry 13 }
|
|
|
|
prvtLmmInterfaceTxPowerLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the low threshold value for port TX-power"
|
|
::= { prvtLmmInterfaceEntry 14 }
|
|
|
|
prvtLmmInterfaceTxPowerHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specify the high threshold value for port TX-power
|
|
Value of prvtLmmInterfaceTxPowerHighThreshold must be greater than
|
|
prvtLmmInterfaceTxPowerLowThreshold"
|
|
::= { prvtLmmInterfaceEntry 15 }
|
|
|
|
prvtLmmInterfaceTxPowerValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Display laser Tx Power current value"
|
|
::= { prvtLmmInterfaceEntry 16 }
|
|
|
|
prvtLmmInterfaceTxPowerThresholdTxLo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The thresholds read from hardware or set by user"
|
|
::= { prvtLmmInterfaceEntry 17 }
|
|
|
|
prvtLmmInterfaceTxPowerThresholdTxHi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The thresholds read from hardware or set by user"
|
|
::= { prvtLmmInterfaceEntry 18 }
|
|
|
|
prvtLmmInterfaceTxPowerTestState OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state test"
|
|
::= { prvtLmmInterfaceEntry 19 }
|
|
|
|
prvtLmmInterfaceOperStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational status"
|
|
::= { prvtLmmInterfaceEntry 20 }
|
|
|
|
prvtLmmTemperatureThresholdCrossed NOTIFICATION-TYPE
|
|
OBJECTS { prvtLmmInterfaceTempValue,
|
|
prvtLmmInterfaceTempThresholdHi,
|
|
prvtLmmInterfaceTempThresholdLo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The prvtLmmTemperatureThresholdCrossed shall be generated
|
|
when prvtLmmInterfaceTempValue rises above prvtLmmInterfaceTempThresholdHi
|
|
or falls below prvtLmmInterfaceTempThresholdLo. Also the
|
|
notification shall be generated when prvtLmmInterfaceTempValue
|
|
returns to the normal range between prvtLmmInterfaceTempThresholdHi
|
|
and prvtLmmInterfaceTempThresholdLo."
|
|
::= { prvtLmmNotifications 1 }
|
|
|
|
prvtLmmTxPowerThresholdCrossed NOTIFICATION-TYPE
|
|
OBJECTS { prvtLmmInterfaceTxPowerValue,
|
|
prvtLmmInterfaceTxPowerThresholdTxHi,
|
|
prvtLmmInterfaceTxPowerThresholdTxLo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The prvtLmmTxPowerThresholdCrossed shall be generated
|
|
when prvtLmmInterfaceTxPowerValue rises above prvtLmmInterfaceTxPowerThresholdTxHi
|
|
or falls below prvtLmmInterfaceTxPowerThresholdTxLo. Also the
|
|
notification shall be generated when prvtLmmInterfaceTxPowerValue
|
|
returns to the normal range between prvtLmmInterfaceTxPowerThresholdTxHi
|
|
and prvtLmmInterfaceTxPowerThresholdTxLo."
|
|
::= { prvtLmmNotifications 2 }
|
|
|
|
prvtLmmRxPowerThresholdCrossed NOTIFICATION-TYPE
|
|
OBJECTS { prvtLmmInterfaceRxPowerValue,
|
|
prvtLmmInterfaceRxPowerThresholdRxHi,
|
|
prvtLmmInterfaceRxPowerThresholdRxLo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The prvtLmmRxPowerThresholdCrossed shall be generated
|
|
when prvtLmmInterfaceRxPowerValue rises above prvtLmmInterfaceRxPowerThresholdRxHi
|
|
or falls below prvtLmmInterfaceRxPowerThresholdRxLo. Also the
|
|
notification shall be generated when prvtLmmInterfaceRxPowerValue
|
|
returns to the normal range between prvtLmmInterfaceRxPowerThresholdRxHi
|
|
and prvtLmmInterfaceRxPowerThresholdRxLo."
|
|
::= { prvtLmmNotifications 3 }
|
|
|
|
END -- end of module PRVT-LMM-MIB.
|