mibs/MIBS/telco-systems/binox/PRVT-OSPF-MIB

1338 lines
44 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-OSPF-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-OSPF-MIB DEFINITIONS ::= BEGIN
IMPORTS
routingProtocols
FROM PRVT-SWITCH-MIB
Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY,
OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC;
prvtOspfMIB MODULE-IDENTITY
LAST-UPDATED "201204010000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The PRVT OSPF MIB module contains additional information, needed to
control the OSPF protocol, that is not found in the standard RFC"
REVISION "201204010000Z"
DESCRIPTION
"Area ID is represent as octet string"
REVISION "201106020000Z"
DESCRIPTION
"Added prvtOspfTrafficEngEnable"
REVISION "200911130000Z"
DESCRIPTION
"Initial version"
::= { routingProtocols 2 }
PrvtOspfDesignatedRouterPriority ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The values defined for the priority of a system for
becoming the designated router."
SYNTAX Integer32 (0..255)
PrvtOspfIpAddress ::= TEXTUAL-CONVENTION
DISPLAY-HINT "1d.1d.1d.1d"
STATUS current
DESCRIPTION
"An IP address.
Currently only IPv4 network addresses are supported.
Format for IPv4 addresses consist of 4 octets in network-byte order."
SYNTAX OCTET STRING (SIZE(4 | 16))
prvtOspfObjects OBJECT IDENTIFIER
::= { prvtOspfMIB 1 }
prvtOspfRouterId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A 32-bit integer uniquely identifying the
router in the Autonomous System.
By convention, to ensure uniqueness, this
should default to the value of one of the
router's IP interface addresses."
REFERENCE
"OSPF Version 2, C.1 Global parameters"
::= { prvtOspfObjects 1 }
prvtOspfAdminStat OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative status of OSPF in the
router. The value 'enabled' denotes that the
OSPF Process is active on at least one interface;
'disabled' disables it on all interfaces."
::= { prvtOspfObjects 2 }
prvtOspfVersionNumber OBJECT-TYPE
SYNTAX INTEGER { version2(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current version number of the OSPF
protocol is 2."
REFERENCE
"OSPF Version 2, Title"
::= { prvtOspfObjects 3 }
prvtOspfExternLsaCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of external (LS type 5) link-state
advertisements in the link-state database."
REFERENCE
"OSPF Version 2, Appendix A.4.5 AS external link
advertisements"
::= { prvtOspfObjects 4 }
prvtOspfExternLsaCksumSum OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 32-bit unsigned sum of the LS checksums of
the external link-state advertisements contained
in the link-state database. This sum
can be used to determine if there has been a
change in a router's link state database, and
to compare the link-state database of two
routers."
::= { prvtOspfObjects 5 }
prvtOspfTOSSupport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The router's support for type-of-service routing."
REFERENCE
"OSPF Version 2, Appendix F.1.2 Optional TOS
support"
::= { prvtOspfObjects 6 }
prvtOspfOriginateNewLsas OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of new link-state advertisements
that have been originated. This number is
incremented each time the router originates a
new LSA."
::= { prvtOspfObjects 7 }
prvtOspfRxNewLsas OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of link-state advertisements re-
ceived determined to be new instantiations.
This number does not include newer instantia-
tions of self-originated link-state advertise-
ments."
::= { prvtOspfObjects 8 }
prvtOspfExtLsdbLimit OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of non-default AS-
external-LSAs entries that can be stored in the
link-state database. If the value is -1, then
there is no limit.
When the number of non-default AS-external-LSAs
in a router's link-state database reaches
ospfExtLsdbLimit, the router enters Overflow-
State. The router never holds more than
ospfExtLsdbLimit non-default AS-external-LSAs
in its database. OspfExtLsdbLimit MUST be set
identically in all routers attached to the OSPF
backbone and/or any regular OSPF area. (i.e.,
OSPF stub areas and NSSAs are excluded)."
::= { prvtOspfObjects 9 }
prvtOspfMulticastExtensions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit Mask indicating whether the router is
forwarding IP multicast (Class D) datagrams
based on the algorithms defined in the Multi-
cast Extensions to OSPF.
Bit 0, if set, indicates that the router can
forward IP multicast datagrams in the router's
directly attached areas (called intra-area mul-
ticast routing).
Bit 1, if set, indicates that the router can
forward IP multicast datagrams between OSPF
areas (called inter-area multicast routing).
Bit 2, if set, indicates that the router can
forward IP multicast datagrams between Auto-
nomous Systems (called inter-AS multicast rout-
ing).
Only certain combinations of bit settings are
allowed, namely: 0 (no multicast forwarding is
enabled), 1 (intra-area multicasting only), 3
(intra-area and inter-area multicasting), 5
(intra-area and inter-AS multicasting) and 7
(multicasting everywhere). By default, no mul-
ticast forwarding is enabled."
::= { prvtOspfObjects 10 }
prvtOspfExitOverflowInterval OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of seconds that, after entering
OverflowState, a router will attempt to leave
OverflowState. This allows the router to again
originate non-default AS-external-LSAs. When
set to 0, the router will not leave Overflow-
State until restarted."
::= { prvtOspfObjects 11 }
prvtOspfDemandExtensions OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The router's support for demand routing."
REFERENCE
"OSPF Version 2, Appendix on Demand Routing"
::= { prvtOspfObjects 12 }
prvtOspfAreaTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfAreaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information describing the configured parameters
and cumulative statistics of the router's
attached areas."
REFERENCE
"OSPF Version 2, Section 6 The Area Data
Structure"
::= { prvtOspfObjects 13 }
prvtOspfAreaEntry OBJECT-TYPE
SYNTAX PrvtOspfAreaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information describing the configured
parameters and cumulative statistics
of one of the router's attached areas."
INDEX { prvtOspfAreaId }
::= { prvtOspfAreaTable 1 }
PrvtOspfAreaEntry ::= SEQUENCE {
prvtOspfAreaId OCTET STRING,
prvtOspfAreaRowStatus RowStatus,
prvtOspfAreaType INTEGER,
prvtOspfAreaSummary INTEGER,
prvtOspfAreaAuthType INTEGER,
prvtOspfAreaShortcutConfiguration TruthValue,
prvtOspfAreaNssaTransitRole INTEGER,
prvtOspfAreaImportList OCTET STRING,
prvtOspfAreaExportList OCTET STRING,
prvtOspfAreaMetric Integer32,
prvtOspfAreaMetricType INTEGER,
prvtOspfAreaDefaultCost Integer32
}
prvtOspfAreaId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An octet string, uniquely identifying area.
Both A.B.C.D or integer notations are supported.
Area ID 0.0.0.0 is used for the OSPF backbone."
REFERENCE
"OSPF Version 2, Appendix C.2 Area parameters"
::= { prvtOspfAreaEntry 1 }
prvtOspfAreaRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable displays the status of the en-
try. Setting it to 'invalid' has the effect of
rendering it inoperative. The internal effect
(row removal) is implementation dependent."
::= { prvtOspfAreaEntry 2 }
prvtOspfAreaType OBJECT-TYPE
SYNTAX INTEGER { default(0), stub(1), nssa(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The area type"
::= { prvtOspfAreaEntry 3 }
prvtOspfAreaSummary OBJECT-TYPE
SYNTAX INTEGER { noAreaSummary(1), sendAreaSummary(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The variable ospfAreaSummary controls the im-
port of summary LSAs into stub areas. It has
no effect on other areas.
If it is noAreaSummary, the router will neither
originate nor propagate summary LSAs into the
stub area. It will rely entirely on its de-
fault route.
If it is sendAreaSummary, the router will both
summarize and propagate summary LSAs."
::= { prvtOspfAreaEntry 4 }
prvtOspfAreaAuthType OBJECT-TYPE
SYNTAX INTEGER { simple(1), md5(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The authentication type specified for an area.
Additional authentication types may be assigned
locally on a per Area basis."
::= { prvtOspfAreaEntry 5 }
prvtOspfAreaShortcutConfiguration OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Allows the user to set whether the area
allows the traffict to pass through other
not backbone area"
::= { prvtOspfAreaEntry 6 }
prvtOspfAreaNssaTransitRole OBJECT-TYPE
SYNTAX INTEGER { ospfNssaRoleNever(0), ospfNssaRoleAlways(1),
ospfNssaRoleCandidate(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Transit role"
::= { prvtOspfAreaEntry 7 }
prvtOspfAreaImportList OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Import List"
::= { prvtOspfAreaEntry 8 }
prvtOspfAreaExportList OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Export List"
::= { prvtOspfAreaEntry 9 }
prvtOspfAreaMetric OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Area metric"
::= { prvtOspfAreaEntry 10 }
prvtOspfAreaMetricType OBJECT-TYPE
SYNTAX INTEGER { ospfMetric(1), comparableCost(2),
nonComparable(3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Area metric type"
::= { prvtOspfAreaEntry 11 }
prvtOspfAreaDefaultCost OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default cost"
::= { prvtOspfAreaEntry 12 }
prvtOspfLsdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfLsdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OSPF Process's Link State Database."
REFERENCE
"OSPF Version 2, Section 12 Link State Adver-
tisements"
::= { prvtOspfObjects 14 }
prvtOspfLsdbEntry OBJECT-TYPE
SYNTAX PrvtOspfLsdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single Link State Advertisement."
INDEX { prvtOspfLsdbAreaId, prvtOspfLsdbType, prvtOspfLsdbLsid,
prvtOspfLsdbRouterId }
::= { prvtOspfLsdbTable 1 }
PrvtOspfLsdbEntry ::= SEQUENCE {
prvtOspfLsdbAreaId IpAddress,
prvtOspfLsdbType INTEGER,
prvtOspfLsdbLsid IpAddress,
prvtOspfLsdbRouterId IpAddress,
prvtOspfLsdbSequence Integer32,
prvtOspfLsdbAge Integer32,
prvtOspfLsdbChecksum Integer32,
prvtOspfLsdbLength Integer32,
prvtOspfLsdbAdvertisement OCTET STRING
}
prvtOspfLsdbAreaId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 32 bit identifier of the Area from which
the LSA was received."
REFERENCE
"OSPF Version 2, Appendix C.2 Area parameters"
::= { prvtOspfLsdbEntry 1 }
prvtOspfLsdbType OBJECT-TYPE
SYNTAX INTEGER { routerLink(1), networkLink(2), summaryLink(3),
asSummaryLink(4), asExternalLink(5),
multicastLink(6), nssaExternalLink(7),
unknownLink(8), opaqueLinkLsa(9), opaqueAreaLsa(10),
opaqueAsLsa(11) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of the link state advertisement.
Each link state type has a separate
advertisement format."
REFERENCE
"OSPF Version 2, Appendix A.4.1 The Link State
Advertisement header"
::= { prvtOspfLsdbEntry 2 }
prvtOspfLsdbLsid OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Link State ID is an LS Type Specific field
containing either a Router ID or an IP Address;
it identifies the piece of the routing domain
that is being described by the advertisement."
REFERENCE
"OSPF Version 2, Section 12.1.4 Link State ID"
::= { prvtOspfLsdbEntry 3 }
prvtOspfLsdbRouterId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 32 bit number that uniquely identifies the
originating router in the Autonomous System."
REFERENCE
"OSPF Version 2, Appendix C.1 Global parameters"
::= { prvtOspfLsdbEntry 4 }
prvtOspfLsdbSequence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sequence number field is a signed 32-bit
integer. It is used to detect old and duplicate
link state advertisements. The space of
sequence numbers is linearly ordered. The
larger the sequence number the more recent the
advertisement."
REFERENCE
"OSPF Version 2, Section 12.1.6 LS sequence
number"
::= { prvtOspfLsdbEntry 5 }
prvtOspfLsdbAge OBJECT-TYPE
SYNTAX Integer32 (-32768..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field is the age of the link state
advertisement in seconds."
REFERENCE
"OSPF Version 2, Section 12.1.1 LS age"
::= { prvtOspfLsdbEntry 6 }
prvtOspfLsdbChecksum OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field is the checksum of the complete
contents of the advertisement, excepting the
age field. The age field is excepted so that
an advertisement's age can be incremented
without updating the checksum. The checksum
used is the same that is used for ISO
connectionless datagrams; it is commonly
referred to as the Fletcher checksum."
REFERENCE
"OSPF Version 2, Section 12.1.7 LS checksum"
::= { prvtOspfLsdbEntry 7 }
prvtOspfLsdbLength OBJECT-TYPE
SYNTAX Integer32 (-32768..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The length of the ospf packet"
::= { prvtOspfLsdbEntry 8 }
prvtOspfLsdbAdvertisement OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entire Link State Advertisement,
including its header."
REFERENCE
"OSPF Version 2, Section 12 Link State
Advertisements"
::= { prvtOspfLsdbEntry 9 }
prvtOspfExtLsdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfExtLsdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OSPF Process's Links State Database."
REFERENCE
"OSPF Version 2, Section 12 Link State Adver-
tisements"
::= { prvtOspfObjects 15 }
prvtOspfExtLsdbEntry OBJECT-TYPE
SYNTAX PrvtOspfExtLsdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single Link State Advertisement."
INDEX { prvtOspfExtLsdbType, prvtOspfExtLsdbLsid,
prvtOspfExtLsdbRouterId }
::= { prvtOspfExtLsdbTable 1 }
PrvtOspfExtLsdbEntry ::= SEQUENCE {
prvtOspfExtLsdbType INTEGER,
prvtOspfExtLsdbLsid IpAddress,
prvtOspfExtLsdbRouterId IpAddress,
prvtOspfExtLsdbSequence Integer32,
prvtOspfExtLsdbAge Integer32,
prvtOspfExtLsdbChecksum Integer32,
prvtOspfExtLsdbAdvertisement OCTET STRING
}
prvtOspfExtLsdbType OBJECT-TYPE
SYNTAX INTEGER { routerLink(1), networkLink(2), summaryLink(3),
asSummaryLink(4), asExternalLink(5),
multicastLink(6), nssaExternalLink(7),
unknownLink(8), opaqueLinkLsa(9), opaqueAreaLsa(10),
opaqueAsLsa(11) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of the link state advertisement.
Each link state type has a separate advertise-
ment format."
REFERENCE
"OSPF Version 2, Appendix A.4.1 The Link State
Advertisement header"
::= { prvtOspfExtLsdbEntry 1 }
prvtOspfExtLsdbLsid OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Link State ID is an LS Type Specific field
containing either a Router ID or an IP Address;
it identifies the piece of the routing domain
that is being described by the advertisement."
REFERENCE
"OSPF Version 2, Section 12.1.4 Link State ID"
::= { prvtOspfExtLsdbEntry 2 }
prvtOspfExtLsdbRouterId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The 32 bit number that uniquely identifies the
originating router in the Autonomous System."
REFERENCE
"OSPF Version 2, Appendix C.1 Global parameters"
::= { prvtOspfExtLsdbEntry 3 }
prvtOspfExtLsdbSequence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sequence number field is a signed 32-bit
integer. It is used to detect old and duplicate
link state advertisements. The space of
sequence numbers is linearly ordered. The
larger the sequence number the more recent the
advertisement."
REFERENCE
"OSPF Version 2, Section 12.1.6 LS sequence
number"
::= { prvtOspfExtLsdbEntry 4 }
prvtOspfExtLsdbAge OBJECT-TYPE
SYNTAX Integer32 (-32768..32767)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field is the age of the link state
advertisement in seconds."
REFERENCE
"OSPF Version 2, Section 12.1.1 LS age"
::= { prvtOspfExtLsdbEntry 5 }
prvtOspfExtLsdbChecksum OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field is the checksum of the complete
contents of the advertisement, excepting the
age field. The age field is excepted so that
an advertisement's age can be incremented
without updating the checksum. The checksum
used is the same that is used for ISO
connectionless datagrams; it is commonly referred
to as the Fletcher checksum."
REFERENCE
"OSPF Version 2, Section 12.1.7 LS checksum"
::= { prvtOspfExtLsdbEntry 6 }
prvtOspfExtLsdbAdvertisement OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entire Link State Advertisement, including
its header."
REFERENCE
"OSPF Version 2, Section 12 Link State Adver-
tisements"
::= { prvtOspfExtLsdbEntry 7 }
prvtOspfIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OSPF Interface Table describes the inter-
faces from the viewpoint of OSPF."
REFERENCE
"OSPF Version 2, Appendix C.3 Router interface
parameters"
::= { prvtOspfObjects 16 }
prvtOspfIfEntry OBJECT-TYPE
SYNTAX PrvtOspfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OSPF Interface Entry describes one inter-
face from the viewpoint of OSPF."
INDEX { prvtOspfIfIpAddress }
::= { prvtOspfIfTable 1 }
PrvtOspfIfEntry ::= SEQUENCE {
prvtOspfIfIpAddress IpAddress,
prvtOspfIfRowStatus RowStatus,
prvtOspfIfAreaId OCTET STRING,
prvtOspfIfWorkingMode INTEGER,
prvtOspfIfTransitDelay Integer32,
prvtOspfIfPriority Integer32,
prvtOspfIfHelloTimer Integer32,
prvtOspfIfDeadTimer Integer32,
prvtOspfIfRetransmitInterval Integer32,
prvtOspfIfOutputCost Integer32,
prvtOspfIfAuthType INTEGER,
prvtOspfIfAuthSimple OCTET STRING,
prvtOspfIfType INTEGER
}
prvtOspfIfIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IP address of this OSPF interface."
::= { prvtOspfIfEntry 1 }
prvtOspfIfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable displays the status of the entry.
Setting it to 'invalid' has the effect of
rendering it inoperative. The internal effect
(row removal) is implementation dependent."
::= { prvtOspfIfEntry 2 }
prvtOspfIfAreaId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An octet string, uniquely identifying area.
Both A.B.C.D or integer notations are supported. Area ID
0.0.0.0 is used for the OSPF backbone."
::= { prvtOspfIfEntry 3 }
prvtOspfIfWorkingMode OBJECT-TYPE
SYNTAX INTEGER { active(0), passive(1) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Working mode"
::= { prvtOspfIfEntry 4 }
prvtOspfIfTransitDelay OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The estimated number of seconds it takes to
transmit a link state update packet over this
interface."
::= { prvtOspfIfEntry 5 }
prvtOspfIfPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The priority of this interface. Used in
multi-access networks, this field is used in
the designated router election algorithm. The
value 0 signifies that the router is not eligible
to become the designated router on this
particular network. In the event of a tie in
this value, routers will use their Router ID as
a tie breaker."
::= { prvtOspfIfEntry 6 }
prvtOspfIfHelloTimer OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The length of time, in seconds, between the
Hello packets that the router sends on the
interface. This value must be the same for all
routers attached to a common network."
::= { prvtOspfIfEntry 7 }
prvtOspfIfDeadTimer OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds that a router's Hello
packets have not been seen before it's neigh-
bors declare the router down. This should be
some multiple of the Hello interval. This
value must be the same for all routers attached
to a common network."
::= { prvtOspfIfEntry 8 }
prvtOspfIfRetransmitInterval OBJECT-TYPE
SYNTAX Integer32 (3..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds between link-state ad-
vertisement retransmissions, for adjacencies
belonging to this interface. This value is
also used when retransmitting database descrip-
tion and link-state request packets."
::= { prvtOspfIfEntry 9 }
prvtOspfIfOutputCost OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"No description in main model!"
::= { prvtOspfIfEntry 10 }
prvtOspfIfAuthType OBJECT-TYPE
SYNTAX INTEGER { simple(1), md5(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set authentication type of interface.
If not set, will use the one from area!"
::= { prvtOspfIfEntry 11 }
prvtOspfIfAuthSimple OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..8))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Simple authentication password (key).Up to 8 characters"
::= { prvtOspfIfEntry 12 }
prvtOspfIfType OBJECT-TYPE
SYNTAX INTEGER { none(0), broadcast(1), nbma(2),
pointToPoint(3), pointToMultipoint(5),
virtualLink(6), loopback(7) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"No description in main model!"
::= { prvtOspfIfEntry 13 }
prvtOspfIfAuthMd5Table OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfIfAuthMd5Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for configuring message digest authentication password"
::= { prvtOspfObjects 17 }
prvtOspfIfAuthMd5Entry OBJECT-TYPE
SYNTAX PrvtOspfIfAuthMd5Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table rows"
INDEX { prvtOspfIfIpAddress, prvtOspfIfAuthMd5Key }
::= { prvtOspfIfAuthMd5Table 1 }
PrvtOspfIfAuthMd5Entry ::= SEQUENCE {
prvtOspfIfAuthMd5Key Integer32,
prvtOspfIfAuthMd5RowStatus RowStatus,
prvtOspfIfAuthMd5Word OCTET STRING
}
prvtOspfIfAuthMd5Key OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Authentication key."
::= { prvtOspfIfAuthMd5Entry 1 }
prvtOspfIfAuthMd5RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus."
::= { prvtOspfIfAuthMd5Entry 2 }
prvtOspfIfAuthMd5Word OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Authentication word."
::= { prvtOspfIfAuthMd5Entry 3 }
prvtOspfNbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfNbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of non-virtual neighbor information."
REFERENCE
"OSPF Version 2, Section 10 The Neighbor Data Structure"
::= { prvtOspfObjects 18 }
prvtOspfNbrEntry OBJECT-TYPE
SYNTAX PrvtOspfNbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information regarding a single neighbor."
REFERENCE
"OSPF Version 2, Section 10 The Neighbor Data Structure"
INDEX { prvtOspfNbrIpAddr, prvtOspfNbrAddressLessIndex }
::= { prvtOspfNbrTable 1 }
PrvtOspfNbrEntry ::= SEQUENCE {
prvtOspfNbrIpAddr PrvtOspfIpAddress,
prvtOspfNbrAddressLessIndex Integer32,
prvtOspfNbrRtrId PrvtOspfIpAddress,
prvtOspfNbrOptions Integer32,
prvtOspfNbrPriority PrvtOspfDesignatedRouterPriority,
prvtOspfNbrState INTEGER,
prvtOspfNbrEvents Counter32,
prvtOspfNbrLsRetransQLen Gauge32,
prvtOspfNbmaNbrPermanence INTEGER,
prvtOspfNbrHelloSuppressed TruthValue
}
prvtOspfNbrIpAddr OBJECT-TYPE
SYNTAX PrvtOspfIpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IP address this neighbor is using in its
IP Source Address. Note that, on addressless
links, this will not be 0.0.0.0, but the ad-
dress of another of the neighbor's interfaces."
::= { prvtOspfNbrEntry 1 }
prvtOspfNbrAddressLessIndex OBJECT-TYPE
SYNTAX Integer32 (-2147483648..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"On an interface having an IP Address, zero.
On addressless interfaces, the corresponding
value of ifIndex in the Internet Standard MIB.
On row creation, this can be derived from the
instance."
::= { prvtOspfNbrEntry 2 }
prvtOspfNbrRtrId OBJECT-TYPE
SYNTAX PrvtOspfIpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A 32-bit integer (represented as a type IpAd-
dress) uniquely identifying the neighboring
router in the Autonomous System."
::= { prvtOspfNbrEntry 3 }
prvtOspfNbrOptions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit Mask corresponding to the neighbor's op-
tions field.
Bit 0, if set, indicates that the system will
operate on Type of Service metrics other than
TOS 0. If zero, the neighbor will ignore all
metrics except the TOS 0 metric.
Bit 1, if set, indicates that the associated
area accepts and operates on external informa-
tion; if zero, it is a stub area.
Bit 2, if set, indicates that the system is ca-
pable of routing IP Multicast datagrams; i.e.,
that it implements the Multicast Extensions to
OSPF.
Bit 3, if set, indicates that the associated
area is an NSSA. These areas are capable of
carrying type 7 external advertisements, which
are translated into type 5 external advertise-
ments at NSSA borders."
REFERENCE
"OSPF Version 2, Section 12.1.2 Options"
::= { prvtOspfNbrEntry 4 }
prvtOspfNbrPriority OBJECT-TYPE
SYNTAX PrvtOspfDesignatedRouterPriority
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority of this neighbor in the designat-
ed router election algorithm. The value 0 sig-
nifies that the neighbor is not eligible to be-
come the designated router on this particular
network."
::= { prvtOspfNbrEntry 5 }
prvtOspfNbrState OBJECT-TYPE
SYNTAX INTEGER { down(1), attempt(2), init(3), twoWay(4),
exchangeStart(5), exchange(6), loading(7), full(8) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The State of the relationship with this Neigh-
bor."
REFERENCE
"OSPF Version 2, Section 10.1 Neighbor States"
::= { prvtOspfNbrEntry 6 }
prvtOspfNbrEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times this neighbor relationship
has changed state, or an error has occurred."
::= { prvtOspfNbrEntry 7 }
prvtOspfNbrLsRetransQLen OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current length of the retransmission queue."
::= { prvtOspfNbrEntry 8 }
prvtOspfNbmaNbrPermanence OBJECT-TYPE
SYNTAX INTEGER { dynamic(1), permanent(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable displays the status of the entry.
'dynamic' and 'permanent' refer to how
the neighbor became known."
::= { prvtOspfNbrEntry 10 }
prvtOspfNbrHelloSuppressed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether Hellos are being suppressed
to the neighbor"
::= { prvtOspfNbrEntry 11 }
prvtOspfRedistributeTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfRedistributeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table represents the routing protocols, redistributed into the OSPF
routing domain.
Creation of conceptual row in the table starts the redistribution of the
specified protocol, which would lead to the injection of routing information
from that protocol into the OSPF.
Deletion of conceptual row would stop the redistribution of that protocol
into the OSPF.
OSPF router, which redistributes routing information from other
protocols, is an ASBR router"
::= { prvtOspfObjects 19 }
prvtOspfRedistributeEntry OBJECT-TYPE
SYNTAX PrvtOspfRedistributeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row represents a routing protocol, redistributed into OSPF"
INDEX { prvtOspfRedistributeProtocol }
::= { prvtOspfRedistributeTable 1 }
PrvtOspfRedistributeEntry ::= SEQUENCE {
prvtOspfRedistributeProtocol INTEGER,
prvtOspfRedistributeRowStatus RowStatus,
prvtOspfRedistributeMetric1 Integer32,
prvtOspfRedistributeMetric2 Integer32,
prvtOspfRedistributeRouteMap OCTET STRING
}
prvtOspfRedistributeProtocol OBJECT-TYPE
SYNTAX INTEGER { kernel(2), connected(3), static(4),
default(17) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The specific routes redistributed into OSPF. For T4R model the valid values
are connected, rip and static.
For all the other models all of the above routes can be redistributed "
::= { prvtOspfRedistributeEntry 1 }
prvtOspfRedistributeRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the status of the row. Setting of this field to active enables the
redistribution of the protocol.
Setting this field to destroy disables the redistribution of the protocol."
::= { prvtOspfRedistributeEntry 2 }
prvtOspfRedistributeMetric1 OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The metric 1, with which the external routes will be redistributed in the OSPF"
::= { prvtOspfRedistributeEntry 3 }
prvtOspfRedistributeMetric2 OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The metric 2, with which the external routes will be redistributed in the OSPF"
::= { prvtOspfRedistributeEntry 4 }
prvtOspfRedistributeRouteMap OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The route map that would filter the redistributed routing information"
::= { prvtOspfRedistributeEntry 5 }
prvtOspfRouterDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfRouterDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about available routers"
::= { prvtOspfObjects 20 }
prvtOspfRouterDataEntry OBJECT-TYPE
SYNTAX PrvtOspfRouterDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row represents a routing entry"
INDEX { prvtOspfRouterDataPrefix, prvtOspfRouterDataType,
prvtOspfRouterDataAreaId }
::= { prvtOspfRouterDataTable 1 }
PrvtOspfRouterDataEntry ::= SEQUENCE {
prvtOspfRouterDataPrefix OCTET STRING,
prvtOspfRouterDataType INTEGER,
prvtOspfRouterDataAreaId OCTET STRING,
prvtOspfRouterDataId IpAddress,
prvtOspfRouterDataCost Unsigned32,
prvtOspfRouterDataCostType Unsigned32,
prvtOspfRouterDataDestType INTEGER,
prvtOspfRouterDataPathType INTEGER,
prvtOspfRouterDataFlags BITS,
prvtOspfRouterDataExternalRouting INTEGER,
prvtOspfRouterDataTag Integer32
}
prvtOspfRouterDataPrefix OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(5))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 1 }
prvtOspfRouterDataType OBJECT-TYPE
SYNTAX INTEGER { network(1), router(2), external(3) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 2 }
prvtOspfRouterDataAreaId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4 | 16))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 3 }
prvtOspfRouterDataId OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 4 }
prvtOspfRouterDataCost OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 5 }
prvtOspfRouterDataCostType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 6 }
prvtOspfRouterDataDestType OBJECT-TYPE
SYNTAX INTEGER { router(1), network(2), disables(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 7 }
prvtOspfRouterDataPathType OBJECT-TYPE
SYNTAX INTEGER { intraArea(1), interArea(2), external1(3),
external3(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 8 }
prvtOspfRouterDataFlags OBJECT-TYPE
SYNTAX BITS { abr(0), asbr(1), virtual(2), unknown(3), nssa(4),
shortcut(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 9 }
prvtOspfRouterDataExternalRouting OBJECT-TYPE
SYNTAX INTEGER { default(0), stub(1), nssa(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 10 }
prvtOspfRouterDataTag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterDataEntry 11 }
prvtOspfRouterPathTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtOspfRouterPathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about available router's paths"
::= { prvtOspfObjects 21 }
prvtOspfRouterPathEntry OBJECT-TYPE
SYNTAX PrvtOspfRouterPathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row represents a routing's path entry"
INDEX { prvtOspfRouterDataPrefix, prvtOspfRouterDataType,
prvtOspfRouterDataAreaId, prvtOspfRouterPathNextHop }
::= { prvtOspfRouterPathTable 1 }
PrvtOspfRouterPathEntry ::= SEQUENCE {
prvtOspfRouterPathNextHop OCTET STRING,
prvtOspfRouterPathAdvertisingRouter OCTET STRING,
prvtOspfRouterPathInterfaceName OCTET STRING
}
prvtOspfRouterPathNextHop OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4 | 16))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterPathEntry 1 }
prvtOspfRouterPathAdvertisingRouter OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4 | 16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterPathEntry 2 }
prvtOspfRouterPathInterfaceName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unknown in main data model"
::= { prvtOspfRouterPathEntry 3 }
prvtOspfTrafficEngEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set to 'true' to enable the traffic engineering extensions of OSPF.
Note that enabling traffic engineering requires that router interface lo1
(PRVT-SWITCH-IPVLAN-MIB::ipInterfaceIpAddress.lo1) be configured with a
valid IP address (not 0.0.0.0 or 127.0.0.1). An attempt to enable traffic
engineering without such a valid address will fail (error returned)."
::= { prvtOspfObjects 22 }
END -- end of module PRVT-OSPF-MIB.