Initial commit
This commit is contained in:
510
MIBS/accedian/ACD-ALARM-MIB
Normal file
510
MIBS/accedian/ACD-ALARM-MIB
Normal file
@ -0,0 +1,510 @@
|
||||
--
|
||||
-- Accedian Enterprise Specific MIB: Structure of Management Information
|
||||
--
|
||||
-- Copyright (c) 2005-2011, Accedian Networks, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- The contents of this document are subject to change without notice.
|
||||
--
|
||||
|
||||
|
||||
ACD-ALARM-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
||||
Unsigned32
|
||||
FROM SNMPv2-SMI
|
||||
DisplayString, TruthValue, DateAndTime
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
sysName
|
||||
FROM SNMPv2-MIB
|
||||
acdMibs
|
||||
FROM ACCEDIAN-SMI;
|
||||
|
||||
acdAlarm MODULE-IDENTITY
|
||||
|
||||
LAST-UPDATED "201110100100Z"
|
||||
ORGANIZATION "Accedian Networks, Inc."
|
||||
CONTACT-INFO
|
||||
"Accedian Technical Assistance Center
|
||||
Accedian Networks, Inc.
|
||||
4878 Levy, suite 202
|
||||
Saint-Laurent, Quebec Canada H4R 2P1
|
||||
E-mail: support@accedian.com"
|
||||
DESCRIPTION
|
||||
"The alarm Table for this Accedian Networks device."
|
||||
|
||||
REVISION "201110100100Z" -- 10 October 2011
|
||||
DESCRIPTION
|
||||
"Add acdAlarmCfgTableLastChangeTid and
|
||||
acdAlarmStatusTableLastChangeTid."
|
||||
|
||||
REVISION "201011100100Z" -- 10 November 2010
|
||||
DESCRIPTION
|
||||
"Fix compliance section."
|
||||
|
||||
REVISION "200902040100Z" -- 4 Feb 2009
|
||||
DESCRIPTION
|
||||
"Add new fields in acdAlarmCfgEntry, acdAlarmActiveState and
|
||||
acdAlarmClearState."
|
||||
|
||||
REVISION "200802010100Z" -- 1 Feb 2008
|
||||
DESCRIPTION
|
||||
"Add UNITS clause to object, where appropriate."
|
||||
|
||||
REVISION "200705220100Z" -- 22 May 2007
|
||||
DESCRIPTION
|
||||
"Add acdAlarmCfgNumber object to Alarm traps."
|
||||
|
||||
REVISION "200612190100Z" -- 19 Dec 2006
|
||||
DESCRIPTION
|
||||
"Add 802.3AH notification enable and msg field in status table."
|
||||
|
||||
REVISION "200608060100Z" -- 6 Aug 2006
|
||||
DESCRIPTION
|
||||
"Initial version of MIB module ACD-ALARM-MIB."
|
||||
|
||||
::= { acdMibs 1 }
|
||||
|
||||
acdAlarmMIBObjects OBJECT IDENTIFIER ::= { acdAlarm 15 }
|
||||
acdAlarmConfig OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 1 }
|
||||
acdAlarmStatus OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 2 }
|
||||
acdAlarmConformance OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 3 }
|
||||
|
||||
acdAlarmTableTid OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 4 }
|
||||
|
||||
---------------------------------------------------------------------------
|
||||
-- Alarm General configuration
|
||||
---------------------------------------------------------------------------
|
||||
acdAlarmGenThreshOn OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (500..50000)
|
||||
UNITS "milliseconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value represents the Alarm On Hysteris. This is the time since the
|
||||
detection of the On event inside the system versus the report. This is
|
||||
to avoid storm of notifications."
|
||||
::= { acdAlarm 1 }
|
||||
|
||||
acdAlarmGenThreshOff OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (500..50000)
|
||||
UNITS "milliseconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value represents the Alarm Off Hysteris. This is the time since the
|
||||
detection of the Off event inside the system versus the report. This is
|
||||
to avoid storm of notifications."
|
||||
::= { acdAlarm 2 }
|
||||
|
||||
acdAlarmGenLedEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is to Enable the alarms reporting through the LEDs."
|
||||
::= { acdAlarm 3 }
|
||||
|
||||
acdAlarmGenSyslogEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is to Enable the alarms reporting through the syslog system."
|
||||
::= { acdAlarm 4 }
|
||||
|
||||
acdAlarmGenSNMPEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is to Enable the alarms reporting through the SNMP agent."
|
||||
::= { acdAlarm 5 }
|
||||
|
||||
acdAlarmGen8023AHEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is to Enable the alarms reporting through the 802.3AH protocol."
|
||||
::= { acdAlarm 6 }
|
||||
|
||||
---------------------------------------------------------------------------
|
||||
-- The Alarm configuration table
|
||||
-- This table contains the configuration for each alarm.
|
||||
---------------------------------------------------------------------------
|
||||
|
||||
acdAlarmCfgTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AcdAlarmCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table of all alarms."
|
||||
::= { acdAlarm 10 }
|
||||
|
||||
acdAlarmCfgEntry OBJECT-TYPE
|
||||
SYNTAX AcdAlarmCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An alarm is an exceptional event that requires user notificaton."
|
||||
INDEX { acdAlarmCfgID }
|
||||
::= { acdAlarmCfgTable 1 }
|
||||
|
||||
AcdAlarmCfgEntry ::= SEQUENCE {
|
||||
acdAlarmCfgID Unsigned32,
|
||||
acdAlarmCfgNumber Unsigned32,
|
||||
acdAlarmCfgDesc DisplayString,
|
||||
acdAlarmCfgEnable TruthValue,
|
||||
acdAlarmCfgSeverity INTEGER,
|
||||
acdAlarmCfgServiceAffecting TruthValue,
|
||||
acdAlarmCfgExtNumber DisplayString,
|
||||
acdAlarmCfgConditionType DisplayString,
|
||||
acdAlarmCfgAMOType DisplayString
|
||||
|
||||
}
|
||||
|
||||
acdAlarmCfgID OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique value for each alarm. Its value ranges from 1 to
|
||||
MAXINT (4 bytes). "
|
||||
::= { acdAlarmCfgEntry 1 }
|
||||
|
||||
acdAlarmCfgNumber OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique number that identifies this alarm. Assigned by the unit. The
|
||||
alarm identifier is compose of 3 fields, the module number, the instance
|
||||
number and the error number. The alarm number looks like this:
|
||||
A.BBB.CC and is expressed in decimal, A is the module number, BBB is
|
||||
the instance number (1-999) and CC is the error number (1-99). A module
|
||||
number is assigned for each source of alarm in the system. For example
|
||||
the port module is set to 1, the SFP module is set to 2, the PAA is set
|
||||
to 3 and the environmental is set to 8."
|
||||
::= { acdAlarmCfgEntry 2 }
|
||||
|
||||
acdAlarmCfgDesc OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..128))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This string is to describe the alarm in a readable way, e.g.:
|
||||
+5Vdc Power supply fail."
|
||||
::= { acdAlarmCfgEntry 3 }
|
||||
|
||||
acdAlarmCfgEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is to indicate if the alarm is reported or not."
|
||||
::= { acdAlarmCfgEntry 4 }
|
||||
|
||||
acdAlarmCfgSeverity OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
info(0),
|
||||
minor(1),
|
||||
major(2),
|
||||
critical(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Accedian Networks classifies alarms into four severity types. These types
|
||||
and their associated decimal codes are, informational(0), minor(1),
|
||||
major(2) and critical(3)."
|
||||
::= { acdAlarmCfgEntry 5 }
|
||||
|
||||
acdAlarmCfgServiceAffecting OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is to indicate if the alarm is service affecting or not. This
|
||||
value depends on the utilization of the box. For instance in an
|
||||
application where the monitoring of the traffic is mandatory the link
|
||||
down event on the monitor port is service affecting."
|
||||
::= { acdAlarmCfgEntry 6 }
|
||||
|
||||
acdAlarmCfgExtNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique number that identifies this alarm. Assigned by the unit. The
|
||||
alarm identifier is compose of 3 fields, the module number, the instance
|
||||
number and the error number. The alarm number looks like this:
|
||||
A.B.C and is expressed in decimal, A is the module number, B is
|
||||
the instance number and C is the error number. A module number is
|
||||
assigned for each source of alarm in the system (see Accedian
|
||||
documentation for more detail)."
|
||||
::= { acdAlarmCfgEntry 7 }
|
||||
|
||||
acdAlarmCfgConditionType OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the type of alarm condition."
|
||||
::= { acdAlarmCfgEntry 8 }
|
||||
|
||||
acdAlarmCfgAMOType OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..128))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the Alarm Maintenance Object."
|
||||
::= { acdAlarmCfgEntry 9 }
|
||||
|
||||
---------------------------------------------------------------------------
|
||||
-- The Alarms Status table
|
||||
-- This table contains the status of all alarms.
|
||||
---------------------------------------------------------------------------
|
||||
|
||||
acdAlarmStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AcdAlarmStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table of all alarms"
|
||||
::= { acdAlarm 11 }
|
||||
|
||||
acdAlarmStatusEntry OBJECT-TYPE
|
||||
SYNTAX AcdAlarmStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An alarm is an exceptional event that requires user notificaton."
|
||||
INDEX { acdAlarmStatusID }
|
||||
::= { acdAlarmStatusTable 1 }
|
||||
|
||||
AcdAlarmStatusEntry ::= SEQUENCE {
|
||||
acdAlarmStatusID Unsigned32,
|
||||
acdAlarmStatusNumber Unsigned32,
|
||||
acdAlarmStatusOn TruthValue,
|
||||
acdAlarmStatusLastChange DateAndTime,
|
||||
acdAlarmStatusMsg DisplayString
|
||||
}
|
||||
|
||||
acdAlarmStatusID OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique value for each alarm. Its value ranges from 1 to
|
||||
MAXINT (4 bytes). "
|
||||
::= { acdAlarmStatusEntry 1 }
|
||||
|
||||
acdAlarmStatusNumber OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique number that identifies this alarm. Assigned by the unit. The
|
||||
alarm identifier is compose of 3 fields, the module number, the instance
|
||||
number and the error number. The alarm number looks like this:
|
||||
AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is
|
||||
the instance number (1-999) and CC is the error number (1-99). A module
|
||||
number is assigned for each source of alarm in the system. For example
|
||||
the port module is set to 1, the SFP module is set to 2, the PAA is set
|
||||
to 3 and the environmental is set to 8."
|
||||
::= { acdAlarmStatusEntry 2 }
|
||||
|
||||
acdAlarmStatusOn OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is to indicate if the alarm is On or Off."
|
||||
::= { acdAlarmStatusEntry 3 }
|
||||
|
||||
acdAlarmStatusLastChange OBJECT-TYPE
|
||||
SYNTAX DateAndTime
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the time of the last change for this alarm. A value of zero
|
||||
means that nothing happened to this alarm since the last reboot."
|
||||
::= { acdAlarmStatusEntry 4 }
|
||||
|
||||
acdAlarmStatusMsg OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This string is to add information why the alarm is reported."
|
||||
::= { acdAlarmStatusEntry 5 }
|
||||
|
||||
-- Accedian Alarm Traps
|
||||
---------------------------------------------------------------------------
|
||||
-- DESCRIPTION "Definition point for Accedian Alarm notifications."
|
||||
---------------------------------------------------------------------------
|
||||
|
||||
acdAlarmV2 OBJECT IDENTIFIER ::= { acdAlarm 12 }
|
||||
|
||||
acdAlarmActiveState NOTIFICATION-TYPE
|
||||
OBJECTS { acdAlarmCfgID,
|
||||
acdAlarmCfgNumber,
|
||||
acdAlarmCfgSeverity,
|
||||
acdAlarmCfgServiceAffecting,
|
||||
acdAlarmCfgDesc,
|
||||
acdAlarmStatusLastChange,
|
||||
acdAlarmCfgExtNumber,
|
||||
acdAlarmCfgConditionType,
|
||||
acdAlarmCfgAMOType,
|
||||
sysName }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The SNMP trap that is generated when an alarm
|
||||
entry crosses its rising threshold and generates
|
||||
an event that is configured for sending SNMP
|
||||
traps."
|
||||
|
||||
::= { acdAlarmV2 1 }
|
||||
|
||||
acdAlarmClearState NOTIFICATION-TYPE
|
||||
OBJECTS { acdAlarmCfgID,
|
||||
acdAlarmCfgNumber,
|
||||
acdAlarmCfgSeverity,
|
||||
acdAlarmCfgServiceAffecting,
|
||||
acdAlarmCfgDesc,
|
||||
acdAlarmStatusLastChange,
|
||||
acdAlarmCfgExtNumber,
|
||||
acdAlarmCfgConditionType,
|
||||
acdAlarmCfgAMOType,
|
||||
sysName }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The SNMP trap that is generated when an alarm
|
||||
entry crosses its falling threshold and generates
|
||||
an event that is configured for sending SNMP
|
||||
traps."
|
||||
|
||||
::= { acdAlarmV2 2 }
|
||||
|
||||
---------------------------------------------------------------------------
|
||||
-- Transaction ID Information
|
||||
---------------------------------------------------------------------------
|
||||
|
||||
acdAlarmCfgTableLastChangeTid OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the transaction ID of the last change of the acdAlarmCfgTable
|
||||
table. If this value is different since the last read this is indicate
|
||||
a table change."
|
||||
::= { acdAlarmTableTid 1 }
|
||||
|
||||
acdAlarmStatusTableLastChangeTid OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the transaction ID of the last change of the acdAlarmStatusTable
|
||||
table. If this value is different since the last read this is indicate
|
||||
a table change."
|
||||
::= { acdAlarmTableTid 2 }
|
||||
|
||||
---------------------------------------------------------------------------
|
||||
-- ACD-ALARM-MIB Module - Conformance Information
|
||||
---------------------------------------------------------------------------
|
||||
|
||||
acdAlarmCompliances OBJECT IDENTIFIER ::= { acdAlarmConformance 1 }
|
||||
acdAlarmGroups OBJECT IDENTIFIER ::= { acdAlarmConformance 2 }
|
||||
|
||||
---------------------------------------------------------------------------
|
||||
-- Units of conformance
|
||||
---------------------------------------------------------------------------
|
||||
|
||||
acdAlarmGenGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
acdAlarmGenThreshOn,
|
||||
acdAlarmGenThreshOff,
|
||||
acdAlarmGenLedEnable,
|
||||
acdAlarmGenSyslogEnable,
|
||||
acdAlarmGenSNMPEnable,
|
||||
acdAlarmGen8023AHEnable
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"."
|
||||
::= { acdAlarmGroups 1 }
|
||||
|
||||
acdAlarmCfgGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
acdAlarmCfgID,
|
||||
acdAlarmCfgNumber,
|
||||
acdAlarmCfgDesc,
|
||||
acdAlarmCfgEnable,
|
||||
acdAlarmCfgSeverity,
|
||||
acdAlarmCfgServiceAffecting,
|
||||
acdAlarmCfgExtNumber,
|
||||
acdAlarmCfgConditionType,
|
||||
acdAlarmCfgAMOType
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"."
|
||||
::= { acdAlarmGroups 2 }
|
||||
|
||||
acdAlarmStatusGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
acdAlarmStatusID,
|
||||
acdAlarmStatusNumber,
|
||||
acdAlarmStatusOn,
|
||||
acdAlarmStatusLastChange,
|
||||
acdAlarmStatusMsg
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"."
|
||||
::= { acdAlarmGroups 3 }
|
||||
|
||||
acdAlarmNotificationsGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
acdAlarmActiveState,
|
||||
acdAlarmClearState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects for the Notifications group."
|
||||
::= { acdAlarmGroups 4 }
|
||||
|
||||
acdAlarmTidGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
acdAlarmCfgTableLastChangeTid,
|
||||
acdAlarmStatusTableLastChangeTid
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of scalars to monitior changes in tables."
|
||||
::= { acdAlarmGroups 5 }
|
||||
|
||||
---------------------------------------------------------------------------
|
||||
-- MIB Module Compliance statements
|
||||
---------------------------------------------------------------------------
|
||||
acdAlarmCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for support of the ACD-ALARM-MIB module."
|
||||
MODULE
|
||||
MANDATORY-GROUPS {
|
||||
acdAlarmGenGroup,
|
||||
acdAlarmCfgGroup,
|
||||
acdAlarmStatusGroup,
|
||||
acdAlarmNotificationsGroup,
|
||||
acdAlarmTidGroup
|
||||
}
|
||||
|
||||
::= { acdAlarmCompliances 1 }
|
||||
|
||||
END
|
Reference in New Issue