mibs/MIBS/accedian/ACD-ALARM-MIB
2023-12-05 12:25:34 +01:00

511 lines
16 KiB
Plaintext

--
-- Accedian Enterprise Specific MIB: Structure of Management Information
--
-- Copyright (c) 2005-2011, Accedian Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--
ACD-ALARM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32
FROM SNMPv2-SMI
DisplayString, TruthValue, DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
sysName
FROM SNMPv2-MIB
acdMibs
FROM ACCEDIAN-SMI;
acdAlarm MODULE-IDENTITY
LAST-UPDATED "201110100100Z"
ORGANIZATION "Accedian Networks, Inc."
CONTACT-INFO
"Accedian Technical Assistance Center
Accedian Networks, Inc.
4878 Levy, suite 202
Saint-Laurent, Quebec Canada H4R 2P1
E-mail: support@accedian.com"
DESCRIPTION
"The alarm Table for this Accedian Networks device."
REVISION "201110100100Z" -- 10 October 2011
DESCRIPTION
"Add acdAlarmCfgTableLastChangeTid and
acdAlarmStatusTableLastChangeTid."
REVISION "201011100100Z" -- 10 November 2010
DESCRIPTION
"Fix compliance section."
REVISION "200902040100Z" -- 4 Feb 2009
DESCRIPTION
"Add new fields in acdAlarmCfgEntry, acdAlarmActiveState and
acdAlarmClearState."
REVISION "200802010100Z" -- 1 Feb 2008
DESCRIPTION
"Add UNITS clause to object, where appropriate."
REVISION "200705220100Z" -- 22 May 2007
DESCRIPTION
"Add acdAlarmCfgNumber object to Alarm traps."
REVISION "200612190100Z" -- 19 Dec 2006
DESCRIPTION
"Add 802.3AH notification enable and msg field in status table."
REVISION "200608060100Z" -- 6 Aug 2006
DESCRIPTION
"Initial version of MIB module ACD-ALARM-MIB."
::= { acdMibs 1 }
acdAlarmMIBObjects OBJECT IDENTIFIER ::= { acdAlarm 15 }
acdAlarmConfig OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 1 }
acdAlarmStatus OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 2 }
acdAlarmConformance OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 3 }
acdAlarmTableTid OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 4 }
---------------------------------------------------------------------------
-- Alarm General configuration
---------------------------------------------------------------------------
acdAlarmGenThreshOn OBJECT-TYPE
SYNTAX Unsigned32 (500..50000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value represents the Alarm On Hysteris. This is the time since the
detection of the On event inside the system versus the report. This is
to avoid storm of notifications."
::= { acdAlarm 1 }
acdAlarmGenThreshOff OBJECT-TYPE
SYNTAX Unsigned32 (500..50000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value represents the Alarm Off Hysteris. This is the time since the
detection of the Off event inside the system versus the report. This is
to avoid storm of notifications."
::= { acdAlarm 2 }
acdAlarmGenLedEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the LEDs."
::= { acdAlarm 3 }
acdAlarmGenSyslogEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the syslog system."
::= { acdAlarm 4 }
acdAlarmGenSNMPEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the SNMP agent."
::= { acdAlarm 5 }
acdAlarmGen8023AHEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to Enable the alarms reporting through the 802.3AH protocol."
::= { acdAlarm 6 }
---------------------------------------------------------------------------
-- The Alarm configuration table
-- This table contains the configuration for each alarm.
---------------------------------------------------------------------------
acdAlarmCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdAlarmCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all alarms."
::= { acdAlarm 10 }
acdAlarmCfgEntry OBJECT-TYPE
SYNTAX AcdAlarmCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An alarm is an exceptional event that requires user notificaton."
INDEX { acdAlarmCfgID }
::= { acdAlarmCfgTable 1 }
AcdAlarmCfgEntry ::= SEQUENCE {
acdAlarmCfgID Unsigned32,
acdAlarmCfgNumber Unsigned32,
acdAlarmCfgDesc DisplayString,
acdAlarmCfgEnable TruthValue,
acdAlarmCfgSeverity INTEGER,
acdAlarmCfgServiceAffecting TruthValue,
acdAlarmCfgExtNumber DisplayString,
acdAlarmCfgConditionType DisplayString,
acdAlarmCfgAMOType DisplayString
}
acdAlarmCfgID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdAlarmCfgEntry 1 }
acdAlarmCfgNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.BBB.CC and is expressed in decimal, A is the module number, BBB is
the instance number (1-999) and CC is the error number (1-99). A module
number is assigned for each source of alarm in the system. For example
the port module is set to 1, the SFP module is set to 2, the PAA is set
to 3 and the environmental is set to 8."
::= { acdAlarmCfgEntry 2 }
acdAlarmCfgDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is to describe the alarm in a readable way, e.g.:
+5Vdc Power supply fail."
::= { acdAlarmCfgEntry 3 }
acdAlarmCfgEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to indicate if the alarm is reported or not."
::= { acdAlarmCfgEntry 4 }
acdAlarmCfgSeverity OBJECT-TYPE
SYNTAX INTEGER {
info(0),
minor(1),
major(2),
critical(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Accedian Networks classifies alarms into four severity types. These types
and their associated decimal codes are, informational(0), minor(1),
major(2) and critical(3)."
::= { acdAlarmCfgEntry 5 }
acdAlarmCfgServiceAffecting OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is to indicate if the alarm is service affecting or not. This
value depends on the utilization of the box. For instance in an
application where the monitoring of the traffic is mandatory the link
down event on the monitor port is service affecting."
::= { acdAlarmCfgEntry 6 }
acdAlarmCfgExtNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.B.C and is expressed in decimal, A is the module number, B is
the instance number and C is the error number. A module number is
assigned for each source of alarm in the system (see Accedian
documentation for more detail)."
::= { acdAlarmCfgEntry 7 }
acdAlarmCfgConditionType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the type of alarm condition."
::= { acdAlarmCfgEntry 8 }
acdAlarmCfgAMOType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the Alarm Maintenance Object."
::= { acdAlarmCfgEntry 9 }
---------------------------------------------------------------------------
-- The Alarms Status table
-- This table contains the status of all alarms.
---------------------------------------------------------------------------
acdAlarmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcdAlarmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of all alarms"
::= { acdAlarm 11 }
acdAlarmStatusEntry OBJECT-TYPE
SYNTAX AcdAlarmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An alarm is an exceptional event that requires user notificaton."
INDEX { acdAlarmStatusID }
::= { acdAlarmStatusTable 1 }
AcdAlarmStatusEntry ::= SEQUENCE {
acdAlarmStatusID Unsigned32,
acdAlarmStatusNumber Unsigned32,
acdAlarmStatusOn TruthValue,
acdAlarmStatusLastChange DateAndTime,
acdAlarmStatusMsg DisplayString
}
acdAlarmStatusID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes). "
::= { acdAlarmStatusEntry 1 }
acdAlarmStatusNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is
the instance number (1-999) and CC is the error number (1-99). A module
number is assigned for each source of alarm in the system. For example
the port module is set to 1, the SFP module is set to 2, the PAA is set
to 3 and the environmental is set to 8."
::= { acdAlarmStatusEntry 2 }
acdAlarmStatusOn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is to indicate if the alarm is On or Off."
::= { acdAlarmStatusEntry 3 }
acdAlarmStatusLastChange OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the time of the last change for this alarm. A value of zero
means that nothing happened to this alarm since the last reboot."
::= { acdAlarmStatusEntry 4 }
acdAlarmStatusMsg OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string is to add information why the alarm is reported."
::= { acdAlarmStatusEntry 5 }
-- Accedian Alarm Traps
---------------------------------------------------------------------------
-- DESCRIPTION "Definition point for Accedian Alarm notifications."
---------------------------------------------------------------------------
acdAlarmV2 OBJECT IDENTIFIER ::= { acdAlarm 12 }
acdAlarmActiveState NOTIFICATION-TYPE
OBJECTS { acdAlarmCfgID,
acdAlarmCfgNumber,
acdAlarmCfgSeverity,
acdAlarmCfgServiceAffecting,
acdAlarmCfgDesc,
acdAlarmStatusLastChange,
acdAlarmCfgExtNumber,
acdAlarmCfgConditionType,
acdAlarmCfgAMOType,
sysName }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps."
::= { acdAlarmV2 1 }
acdAlarmClearState NOTIFICATION-TYPE
OBJECTS { acdAlarmCfgID,
acdAlarmCfgNumber,
acdAlarmCfgSeverity,
acdAlarmCfgServiceAffecting,
acdAlarmCfgDesc,
acdAlarmStatusLastChange,
acdAlarmCfgExtNumber,
acdAlarmCfgConditionType,
acdAlarmCfgAMOType,
sysName }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps."
::= { acdAlarmV2 2 }
---------------------------------------------------------------------------
-- Transaction ID Information
---------------------------------------------------------------------------
acdAlarmCfgTableLastChangeTid OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the transaction ID of the last change of the acdAlarmCfgTable
table. If this value is different since the last read this is indicate
a table change."
::= { acdAlarmTableTid 1 }
acdAlarmStatusTableLastChangeTid OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the transaction ID of the last change of the acdAlarmStatusTable
table. If this value is different since the last read this is indicate
a table change."
::= { acdAlarmTableTid 2 }
---------------------------------------------------------------------------
-- ACD-ALARM-MIB Module - Conformance Information
---------------------------------------------------------------------------
acdAlarmCompliances OBJECT IDENTIFIER ::= { acdAlarmConformance 1 }
acdAlarmGroups OBJECT IDENTIFIER ::= { acdAlarmConformance 2 }
---------------------------------------------------------------------------
-- Units of conformance
---------------------------------------------------------------------------
acdAlarmGenGroup OBJECT-GROUP
OBJECTS {
acdAlarmGenThreshOn,
acdAlarmGenThreshOff,
acdAlarmGenLedEnable,
acdAlarmGenSyslogEnable,
acdAlarmGenSNMPEnable,
acdAlarmGen8023AHEnable
}
STATUS current
DESCRIPTION
"."
::= { acdAlarmGroups 1 }
acdAlarmCfgGroup OBJECT-GROUP
OBJECTS {
acdAlarmCfgID,
acdAlarmCfgNumber,
acdAlarmCfgDesc,
acdAlarmCfgEnable,
acdAlarmCfgSeverity,
acdAlarmCfgServiceAffecting,
acdAlarmCfgExtNumber,
acdAlarmCfgConditionType,
acdAlarmCfgAMOType
}
STATUS current
DESCRIPTION
"."
::= { acdAlarmGroups 2 }
acdAlarmStatusGroup OBJECT-GROUP
OBJECTS {
acdAlarmStatusID,
acdAlarmStatusNumber,
acdAlarmStatusOn,
acdAlarmStatusLastChange,
acdAlarmStatusMsg
}
STATUS current
DESCRIPTION
"."
::= { acdAlarmGroups 3 }
acdAlarmNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
acdAlarmActiveState,
acdAlarmClearState
}
STATUS current
DESCRIPTION
"Objects for the Notifications group."
::= { acdAlarmGroups 4 }
acdAlarmTidGroup OBJECT-GROUP
OBJECTS {
acdAlarmCfgTableLastChangeTid,
acdAlarmStatusTableLastChangeTid
}
STATUS current
DESCRIPTION
"List of scalars to monitior changes in tables."
::= { acdAlarmGroups 5 }
---------------------------------------------------------------------------
-- MIB Module Compliance statements
---------------------------------------------------------------------------
acdAlarmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for support of the ACD-ALARM-MIB module."
MODULE
MANDATORY-GROUPS {
acdAlarmGenGroup,
acdAlarmCfgGroup,
acdAlarmStatusGroup,
acdAlarmNotificationsGroup,
acdAlarmTidGroup
}
::= { acdAlarmCompliances 1 }
END