CM-PROTECTION-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Integer32
|
||||
FROM SNMPv2-SMI
|
||||
DisplayString, TruthValue, RowStatus, StorageType, VariablePointer,
|
||||
MacAddress, TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
neIndex, shelfIndex, slotIndex
|
||||
FROM CM-ENTITY-MIB
|
||||
fsp150cm
|
||||
FROM ADVA-MIB;
|
||||
|
||||
cmProtectionMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201006230000Z"
|
||||
ORGANIZATION "ADVA Optical Networking"
|
||||
CONTACT-INFO
|
||||
" Raghav Trivedi
|
||||
ADVA Optical Networking, Inc.
|
||||
Tel: +1 972 759-1239
|
||||
E-mail: rtrivedi@advaoptical.com
|
||||
Postal: 2301 N. Greenville Ave. #300
|
||||
Richardson, TX USA 75082"
|
||||
DESCRIPTION
|
||||
"This module defines the Protection MIB definitions used by
|
||||
the F3 (FSP150CM/CC) product lines.
|
||||
Copyright (C) ADVA Optical Networking."
|
||||
REVISION "201006230000Z"
|
||||
DESCRIPTION
|
||||
"Notes from release 201006230000Z,
|
||||
(1)Added universalring as CmProtSwitchMode for R4.4CC.
|
||||
|
||||
Notes from release 200803030000Z,
|
||||
(1)MIB version ready for release FSP150CM 3.1."
|
||||
::= {fsp150cm 7}
|
||||
|
||||
--
|
||||
-- OID definitions
|
||||
--
|
||||
cmProtObjects OBJECT IDENTIFIER ::= {cmProtectionMIB 1}
|
||||
cmProtNotifications OBJECT IDENTIFIER ::= {cmProtectionMIB 2}
|
||||
cmProtConformance OBJECT IDENTIFIER ::= {cmProtectionMIB 3}
|
||||
|
||||
--
|
||||
-- Textual Conventions
|
||||
--
|
||||
CmProtSwitchMode ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerations for Protection Switch Mode.
|
||||
oneplusone - 1+1, this is the NPCUP mode,
|
||||
dualactiverx - In this mode, traffic is bridged in A2N
|
||||
direction (same as 1+1), however
|
||||
both network ports receive customer traffic in
|
||||
N2A direction. In this mode, both network
|
||||
ports are working, i.e. there is no
|
||||
protection.
|
||||
universalring - In this mode, traffic is bridged in A2N
|
||||
direction (same as 1+1), both
|
||||
network ports receive customer traffic in
|
||||
N2A direction. In this mode, both network
|
||||
ports are working, i.e. no protection.
|
||||
The main difference w.r.t dualactiverx is that
|
||||
traffic in N2A direction, which does not match
|
||||
the service definition is steered to the other
|
||||
network port, i.e. non-service matching traffic
|
||||
from N1 goes to N2 and vice versa."
|
||||
SYNTAX INTEGER {
|
||||
oneplusone (1),
|
||||
dualactiverx(2),
|
||||
universalring(3)
|
||||
}
|
||||
|
||||
CmProtSwitchDirection ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerations for Protection Switch Direction.
|
||||
unidirectional - Unidirectional Protection Switching,
|
||||
bidirectional - Bidirectional Protection Switching."
|
||||
SYNTAX INTEGER {
|
||||
unidirectional (1),
|
||||
bidirectional (2)
|
||||
}
|
||||
|
||||
CmProtSwitchAction ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerations for User initiated Protection Switch Action.
|
||||
manualfromworking - Manual Switch from Working,
|
||||
forcedfromworking - Forced Switch from Working,
|
||||
manualfromprotect - Manual Switch from Protect,
|
||||
forcedfromprotect - Forced Switch from Protect,
|
||||
lockoutfromprotect - Lockout from Protect"
|
||||
SYNTAX INTEGER {
|
||||
none (1),
|
||||
releaseprotswitch (2),
|
||||
manualfromworking (3),
|
||||
forcedfromworking (4),
|
||||
manualfromprotect (5),
|
||||
forcedfromprotect (6),
|
||||
lockoutfromprotect(7)
|
||||
}
|
||||
|
||||
CmProtUnitType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerations for Protection Unit Type.
|
||||
working - Working Protection Unit,
|
||||
protect - Protect Protection Unit."
|
||||
SYNTAX INTEGER {
|
||||
working (1),
|
||||
protect (2)
|
||||
}
|
||||
|
||||
CmProtUnitState ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerations for Protection Unit State.
|
||||
active - Active Protection Unit,
|
||||
standby - Standby Protection Unit."
|
||||
SYNTAX INTEGER {
|
||||
active (1),
|
||||
standby (2)
|
||||
}
|
||||
|
||||
CmProtGroupStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerations for Protection Status.
|
||||
nooutstandingreq - No oustanding request,
|
||||
sf-protect - Signal failure on protect,
|
||||
sf-working - Signal failure on working,
|
||||
sd-protect - Signal degrade on protect,
|
||||
sd-working - Signal degrade on working,
|
||||
manual-protect - Manual on protect
|
||||
manual-working - Manual on working
|
||||
forced-working - Forced on working
|
||||
forced-protect - Forced on protect
|
||||
lockout-protect - Lockout on protect
|
||||
waitToRestore - Wait to restore"
|
||||
SYNTAX INTEGER {
|
||||
nooutstandingreq (1),
|
||||
sf-protect (2),
|
||||
sf-working (3),
|
||||
sd-protect (4),
|
||||
sd-working (5),
|
||||
manual-protect (6),
|
||||
manual-working (7),
|
||||
forced-protect (8),
|
||||
forced-working (9),
|
||||
lockout-protect (10),
|
||||
waitToRestore (11)
|
||||
}
|
||||
|
||||
--
|
||||
-- Facility Protection Group Table
|
||||
--
|
||||
cmFacProtGroupTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CmFacProtGroupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of entries corresponding to the Facility Protection Groups.
|
||||
Entries can be created/deleted in this table by management
|
||||
application action."
|
||||
::= { cmProtObjects 1 }
|
||||
|
||||
cmFacProtGroupEntry OBJECT-TYPE
|
||||
SYNTAX CmFacProtGroupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing information applicable to a particular
|
||||
Protection Group."
|
||||
INDEX { neIndex, shelfIndex, slotIndex, cmFacProtGroupIndex }
|
||||
::= { cmFacProtGroupTable 1 }
|
||||
|
||||
CmFacProtGroupEntry ::= SEQUENCE {
|
||||
cmFacProtGroupIndex Integer32,
|
||||
cmFacProtGroupUserLabel DisplayString,
|
||||
cmFacProtGroupSwitchMode CmProtSwitchMode,
|
||||
cmFacProtGroupRevertive TruthValue,
|
||||
cmFacProtGroupWaitToRestore Integer32,
|
||||
cmFacProtGroupDirection CmProtSwitchDirection,
|
||||
cmFacProtGroupWorkPort VariablePointer,
|
||||
cmFacProtGroupProtPort VariablePointer,
|
||||
cmFacProtGroupStatus CmProtGroupStatus,
|
||||
cmFacProtGroupAction CmProtSwitchAction,
|
||||
cmFacProtGroupStorageType StorageType,
|
||||
cmFacProtGroupRowStatus RowStatus,
|
||||
cmFacProtGroupMacAddress MacAddress
|
||||
}
|
||||
|
||||
cmFacProtGroupIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index value associated with the Facility Protection Group."
|
||||
::= { cmFacProtGroupEntry 1 }
|
||||
|
||||
cmFacProtGroupUserLabel OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..64))
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"User Label associated with the Facility Protection Group."
|
||||
::= { cmFacProtGroupEntry 2 }
|
||||
|
||||
cmFacProtGroupSwitchMode OBJECT-TYPE
|
||||
SYNTAX CmProtSwitchMode
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Facility Protection Group's Protection Switch Mode."
|
||||
::= { cmFacProtGroupEntry 3 }
|
||||
|
||||
cmFacProtGroupRevertive OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Whether the Facility Protection is revertive or not.
|
||||
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'."
|
||||
::= { cmFacProtGroupEntry 4 }
|
||||
|
||||
cmFacProtGroupWaitToRestore OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..60|0)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Time in minutes to wait before reverting to Working facility
|
||||
in case of cmFacProtGroupRevertive set to revertive.
|
||||
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'."
|
||||
::= { cmFacProtGroupEntry 5 }
|
||||
|
||||
cmFacProtGroupDirection OBJECT-TYPE
|
||||
SYNTAX CmProtSwitchDirection
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Supported Protection Group Switch direction.
|
||||
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'."
|
||||
::= { cmFacProtGroupEntry 6 }
|
||||
|
||||
cmFacProtGroupWorkPort OBJECT-TYPE
|
||||
SYNTAX VariablePointer
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Facility Protection Group exists between 2 facilities (ports).
|
||||
This object represents the WORKING facility Port."
|
||||
::= { cmFacProtGroupEntry 7 }
|
||||
|
||||
cmFacProtGroupProtPort OBJECT-TYPE
|
||||
SYNTAX VariablePointer
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object
|
||||
represents the PROTECT facility Network Element Port when
|
||||
cmFacProtGroupSwitchMode is oneplusone. In the case of
|
||||
dualactiverx, this represents the second active port."
|
||||
::= { cmFacProtGroupEntry 8 }
|
||||
|
||||
cmFacProtGroupStatus OBJECT-TYPE
|
||||
SYNTAX CmProtGroupStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object represents the PROTECTION group status."
|
||||
::= { cmFacProtGroupEntry 9 }
|
||||
|
||||
cmFacProtGroupAction OBJECT-TYPE
|
||||
SYNTAX CmProtSwitchAction
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"User initiated protection switch action."
|
||||
::= { cmFacProtGroupEntry 10 }
|
||||
|
||||
cmFacProtGroupStorageType OBJECT-TYPE
|
||||
SYNTAX StorageType
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of storage configured for this entry."
|
||||
::= { cmFacProtGroupEntry 11 }
|
||||
|
||||
cmFacProtGroupRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of this row. An entry MUST NOT exist in the
|
||||
active state unless all objects in the entry have an
|
||||
appropriate value, as described
|
||||
in the description clause for each writable object.
|
||||
|
||||
The values of cmFacProtGroupRowStatus supported are
|
||||
createAndGo(4) and destroy(6). All mandatory attributes
|
||||
must be specified in a single SNMP SET request with
|
||||
cmFacProtGroupRowStatus value as createAndGo(4).
|
||||
Upon successful row creation, this object has a
|
||||
value of active(1).
|
||||
|
||||
The cmFacProtGroupRowStatus object may be modified if
|
||||
the associated instance of this object is equal to active(1)."
|
||||
::= { cmFacProtGroupEntry 12 }
|
||||
|
||||
cmFacProtGroupMacAddress OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object allows retrieval of the Mac Address of the PROTECTION group."
|
||||
::= { cmFacProtGroupEntry 13 }
|
||||
|
||||
|
||||
--
|
||||
-- Facility Protection Unit Table
|
||||
--
|
||||
cmFacProtUnitTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CmFacProtUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of entries corresponding to the Facility Protection
|
||||
Units."
|
||||
::= { cmProtObjects 2 }
|
||||
|
||||
cmFacProtUnitEntry OBJECT-TYPE
|
||||
SYNTAX CmFacProtUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing information applicable to a particular
|
||||
Protection Unit."
|
||||
INDEX { neIndex, shelfIndex, slotIndex, cmFacProtGroupIndex, cmFacProtUnitIndex }
|
||||
::= { cmFacProtUnitTable 1 }
|
||||
|
||||
CmFacProtUnitEntry ::= SEQUENCE {
|
||||
cmFacProtUnitIndex Integer32,
|
||||
cmFacProtUnitType CmProtUnitType,
|
||||
cmFacProtUnitState CmProtUnitState,
|
||||
cmFacProtUnitPort VariablePointer
|
||||
}
|
||||
|
||||
cmFacProtUnitIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index value associated with the Facility Protection Unit."
|
||||
::= { cmFacProtUnitEntry 1 }
|
||||
|
||||
cmFacProtUnitType OBJECT-TYPE
|
||||
SYNTAX CmProtUnitType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Facility Protection Unit's Type, i.e. whether working or protect."
|
||||
::= { cmFacProtUnitEntry 2 }
|
||||
|
||||
cmFacProtUnitState OBJECT-TYPE
|
||||
SYNTAX CmProtUnitState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Facility Protection Unit's State, i.e. whether active or standby."
|
||||
::= { cmFacProtUnitEntry 3 }
|
||||
|
||||
cmFacProtUnitPort OBJECT-TYPE
|
||||
SYNTAX VariablePointer
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Facility Protection Unit's points to a facility (port).
|
||||
This object represents the facility Network Element port."
|
||||
::= { cmFacProtUnitEntry 4 }
|
||||
|
||||
|
||||
--
|
||||
-- Multiplex Section Protection Group Table
|
||||
--
|
||||
cmMSPGroupTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CmMSPGroupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of entries corresponding to the Multiplex Section Protection Groups.
|
||||
Entries can be created/deleted in this table by management
|
||||
application action."
|
||||
::= { cmProtObjects 3 }
|
||||
|
||||
cmMSPGroupEntry OBJECT-TYPE
|
||||
SYNTAX CmMSPGroupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing information applicable to a particular
|
||||
Protection Group."
|
||||
INDEX { neIndex, cmMSPGroupIndex }
|
||||
::= { cmMSPGroupTable 1 }
|
||||
|
||||
CmMSPGroupEntry ::= SEQUENCE {
|
||||
cmMSPGroupIndex Integer32,
|
||||
cmMSPGroupUserLabel DisplayString,
|
||||
cmMSPGroupSwitchMode CmProtSwitchMode,
|
||||
cmMSPGroupRevertive TruthValue,
|
||||
cmMSPGroupWaitToRestore Integer32,
|
||||
cmMSPGroupB2DEGTrigger TruthValue,
|
||||
cmMSPGroupDirection CmProtSwitchDirection,
|
||||
cmMSPGroupWorkPort VariablePointer,
|
||||
cmMSPGroupProtPort VariablePointer,
|
||||
cmMSPGroupStatus CmProtGroupStatus,
|
||||
cmMSPGroupAction CmProtSwitchAction,
|
||||
cmMSPGroupStorageType StorageType,
|
||||
cmMSPGroupRowStatus RowStatus,
|
||||
cmMSPGroupMacAddress MacAddress
|
||||
}
|
||||
|
||||
cmMSPGroupIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index value associated with the Multiplex Section Protection Group."
|
||||
::= { cmMSPGroupEntry 1 }
|
||||
|
||||
cmMSPGroupUserLabel OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..64))
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"User Label associated with the Multiplex Section Protection Group."
|
||||
::= { cmMSPGroupEntry 2 }
|
||||
|
||||
cmMSPGroupSwitchMode OBJECT-TYPE
|
||||
SYNTAX CmProtSwitchMode
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Multiplex Section Protection Group's Protection Switch Mode."
|
||||
::= { cmMSPGroupEntry 3 }
|
||||
|
||||
cmMSPGroupRevertive OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Whether the Multiplex Section Protection is revertive or not.
|
||||
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'."
|
||||
::= { cmMSPGroupEntry 4 }
|
||||
|
||||
cmMSPGroupWaitToRestore OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..60|0)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Time in minutes to wait before reverting to Working facility
|
||||
in case of cmMSPGroupRevertive set to revertive.
|
||||
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'."
|
||||
::= { cmMSPGroupEntry 5 }
|
||||
|
||||
cmMSPGroupB2DEGTrigger OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"B2DEG is trigger of MSP or not."
|
||||
::= { cmMSPGroupEntry 6 }
|
||||
|
||||
cmMSPGroupDirection OBJECT-TYPE
|
||||
SYNTAX CmProtSwitchDirection
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Supported Protection Group Switch direction.
|
||||
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'."
|
||||
::= { cmMSPGroupEntry 7 }
|
||||
|
||||
cmMSPGroupWorkPort OBJECT-TYPE
|
||||
SYNTAX VariablePointer
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Multiplex Section Protection Group exists between 2 facilities (ports).
|
||||
This object represents the WORKING facility Port."
|
||||
::= { cmMSPGroupEntry 8 }
|
||||
|
||||
cmMSPGroupProtPort OBJECT-TYPE
|
||||
SYNTAX VariablePointer
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object
|
||||
represents the PROTECT facility Network Element Port when
|
||||
cmMSPGroupSwitchMode is oneplusone. In the case of
|
||||
dualactiverx, this represents the second active port."
|
||||
::= { cmMSPGroupEntry 9 }
|
||||
|
||||
cmMSPGroupStatus OBJECT-TYPE
|
||||
SYNTAX CmProtGroupStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object represents the PROTECTION group status."
|
||||
::= { cmMSPGroupEntry 10 }
|
||||
|
||||
cmMSPGroupAction OBJECT-TYPE
|
||||
SYNTAX CmProtSwitchAction
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"User initiated protection switch action."
|
||||
::= { cmMSPGroupEntry 11 }
|
||||
|
||||
cmMSPGroupStorageType OBJECT-TYPE
|
||||
SYNTAX StorageType
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of storage configured for this entry."
|
||||
::= { cmMSPGroupEntry 12 }
|
||||
|
||||
cmMSPGroupRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of this row. An entry MUST NOT exist in the
|
||||
active state unless all objects in the entry have an
|
||||
appropriate value, as described
|
||||
in the description clause for each writable object.
|
||||
|
||||
The values of cmMSPGroupRowStatus supported are
|
||||
createAndGo(4) and destroy(6). All mandatory attributes
|
||||
must be specified in a single SNMP SET request with
|
||||
cmMSPGroupRowStatus value as createAndGo(4).
|
||||
Upon successful row creation, this object has a
|
||||
value of active(1).
|
||||
|
||||
The cmMSPGroupRowStatus object may be modified if
|
||||
the associated instance of this object is equal to active(1)."
|
||||
::= { cmMSPGroupEntry 13 }
|
||||
|
||||
cmMSPGroupMacAddress OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object allows retrieval of the Mac Address of the PROTECTION group."
|
||||
::= { cmMSPGroupEntry 14 }
|
||||
|
||||
|
||||
--
|
||||
-- Multiplex Section Protection Unit Table
|
||||
--
|
||||
cmMSPUnitTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CmMSPUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of entries corresponding to the Multiplex Section Protection
|
||||
Units."
|
||||
::= { cmProtObjects 4 }
|
||||
|
||||
cmMSPUnitEntry OBJECT-TYPE
|
||||
SYNTAX CmMSPUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing information applicable to a particular
|
||||
Protection Unit."
|
||||
INDEX { neIndex, cmMSPGroupIndex, cmMSPUnitIndex }
|
||||
::= { cmMSPUnitTable 1 }
|
||||
|
||||
CmMSPUnitEntry ::= SEQUENCE {
|
||||
cmMSPUnitIndex Integer32,
|
||||
cmMSPUnitType CmProtUnitType,
|
||||
cmMSPUnitState CmProtUnitState,
|
||||
cmMSPUnitPort VariablePointer
|
||||
}
|
||||
|
||||
cmMSPUnitIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index value associated with the Multiplex Section Protection Unit."
|
||||
::= { cmMSPUnitEntry 1 }
|
||||
|
||||
cmMSPUnitType OBJECT-TYPE
|
||||
SYNTAX CmProtUnitType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Multiplex Section Protection Unit's Type, i.e. whether working or protect."
|
||||
::= { cmMSPUnitEntry 2 }
|
||||
|
||||
cmMSPUnitState OBJECT-TYPE
|
||||
SYNTAX CmProtUnitState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Multiplex Section Protection Unit's State, i.e. whether active or standby."
|
||||
::= { cmMSPUnitEntry 3 }
|
||||
|
||||
cmMSPUnitPort OBJECT-TYPE
|
||||
SYNTAX VariablePointer
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Facility Protection Unit's points to a facility (port).
|
||||
This object represents the facility Network Element port."
|
||||
::= { cmMSPUnitEntry 4 }
|
||||
|
||||
|
||||
--
|
||||
-- Conformance
|
||||
--
|
||||
cmProtCompliances OBJECT IDENTIFIER ::= {cmProtConformance 1}
|
||||
cmProtGroups OBJECT IDENTIFIER ::= {cmProtConformance 2}
|
||||
|
||||
cmProtCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes the requirements for conformance to the CM Prot
|
||||
group."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
cmProtObjectGroup, cmMSProtObjectGroup
|
||||
}
|
||||
::= { cmProtCompliances 1 }
|
||||
|
||||
cmProtObjectGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
cmFacProtGroupIndex, cmFacProtGroupUserLabel, cmFacProtGroupSwitchMode,
|
||||
cmFacProtGroupRevertive, cmFacProtGroupWaitToRestore,
|
||||
cmFacProtGroupDirection, cmFacProtGroupWorkPort,
|
||||
cmFacProtGroupProtPort, cmFacProtGroupStatus, cmFacProtGroupAction,
|
||||
cmFacProtGroupStorageType, cmFacProtGroupRowStatus,
|
||||
cmFacProtGroupMacAddress,
|
||||
|
||||
cmFacProtUnitIndex, cmFacProtUnitType, cmFacProtUnitState,
|
||||
cmFacProtUnitPort
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects used to manage the Protection Object group."
|
||||
::= { cmProtGroups 1 }
|
||||
|
||||
cmMSProtObjectGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
cmMSPGroupIndex, cmMSPGroupUserLabel,
|
||||
cmMSPGroupSwitchMode, cmMSPGroupRevertive,
|
||||
cmMSPGroupWaitToRestore, cmMSPGroupB2DEGTrigger,
|
||||
cmMSPGroupDirection, cmMSPGroupWorkPort,
|
||||
cmMSPGroupProtPort, cmMSPGroupStatus,
|
||||
cmMSPGroupAction, cmMSPGroupStorageType,
|
||||
cmMSPGroupRowStatus, cmMSPGroupMacAddress,
|
||||
|
||||
cmMSPUnitIndex, cmMSPUnitType,
|
||||
cmMSPUnitState, cmMSPUnitPort
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects used to manage the Multiplex
|
||||
Section Protection Object group."
|
||||
::= { cmProtGroups 2 }
|
||||
|
||||
END
|