mibs/MIBS/adva/CM-PROTECTION-MIB
2023-12-05 12:25:34 +01:00

676 lines
22 KiB
Plaintext

CM-PROTECTION-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
MODULE-IDENTITY, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
DisplayString, TruthValue, RowStatus, StorageType, VariablePointer,
MacAddress, TEXTUAL-CONVENTION
FROM SNMPv2-TC
neIndex, shelfIndex, slotIndex
FROM CM-ENTITY-MIB
fsp150cm
FROM ADVA-MIB;
cmProtectionMIB MODULE-IDENTITY
LAST-UPDATED "201006230000Z"
ORGANIZATION "ADVA Optical Networking"
CONTACT-INFO
" Raghav Trivedi
ADVA Optical Networking, Inc.
Tel: +1 972 759-1239
E-mail: rtrivedi@advaoptical.com
Postal: 2301 N. Greenville Ave. #300
Richardson, TX USA 75082"
DESCRIPTION
"This module defines the Protection MIB definitions used by
the F3 (FSP150CM/CC) product lines.
Copyright (C) ADVA Optical Networking."
REVISION "201006230000Z"
DESCRIPTION
"Notes from release 201006230000Z,
(1)Added universalring as CmProtSwitchMode for R4.4CC.
Notes from release 200803030000Z,
(1)MIB version ready for release FSP150CM 3.1."
::= {fsp150cm 7}
--
-- OID definitions
--
cmProtObjects OBJECT IDENTIFIER ::= {cmProtectionMIB 1}
cmProtNotifications OBJECT IDENTIFIER ::= {cmProtectionMIB 2}
cmProtConformance OBJECT IDENTIFIER ::= {cmProtectionMIB 3}
--
-- Textual Conventions
--
CmProtSwitchMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerations for Protection Switch Mode.
oneplusone - 1+1, this is the NPCUP mode,
dualactiverx - In this mode, traffic is bridged in A2N
direction (same as 1+1), however
both network ports receive customer traffic in
N2A direction. In this mode, both network
ports are working, i.e. there is no
protection.
universalring - In this mode, traffic is bridged in A2N
direction (same as 1+1), both
network ports receive customer traffic in
N2A direction. In this mode, both network
ports are working, i.e. no protection.
The main difference w.r.t dualactiverx is that
traffic in N2A direction, which does not match
the service definition is steered to the other
network port, i.e. non-service matching traffic
from N1 goes to N2 and vice versa."
SYNTAX INTEGER {
oneplusone (1),
dualactiverx(2),
universalring(3)
}
CmProtSwitchDirection ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerations for Protection Switch Direction.
unidirectional - Unidirectional Protection Switching,
bidirectional - Bidirectional Protection Switching."
SYNTAX INTEGER {
unidirectional (1),
bidirectional (2)
}
CmProtSwitchAction ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerations for User initiated Protection Switch Action.
manualfromworking - Manual Switch from Working,
forcedfromworking - Forced Switch from Working,
manualfromprotect - Manual Switch from Protect,
forcedfromprotect - Forced Switch from Protect,
lockoutfromprotect - Lockout from Protect"
SYNTAX INTEGER {
none (1),
releaseprotswitch (2),
manualfromworking (3),
forcedfromworking (4),
manualfromprotect (5),
forcedfromprotect (6),
lockoutfromprotect(7)
}
CmProtUnitType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerations for Protection Unit Type.
working - Working Protection Unit,
protect - Protect Protection Unit."
SYNTAX INTEGER {
working (1),
protect (2)
}
CmProtUnitState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerations for Protection Unit State.
active - Active Protection Unit,
standby - Standby Protection Unit."
SYNTAX INTEGER {
active (1),
standby (2)
}
CmProtGroupStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerations for Protection Status.
nooutstandingreq - No oustanding request,
sf-protect - Signal failure on protect,
sf-working - Signal failure on working,
sd-protect - Signal degrade on protect,
sd-working - Signal degrade on working,
manual-protect - Manual on protect
manual-working - Manual on working
forced-working - Forced on working
forced-protect - Forced on protect
lockout-protect - Lockout on protect
waitToRestore - Wait to restore"
SYNTAX INTEGER {
nooutstandingreq (1),
sf-protect (2),
sf-working (3),
sd-protect (4),
sd-working (5),
manual-protect (6),
manual-working (7),
forced-protect (8),
forced-working (9),
lockout-protect (10),
waitToRestore (11)
}
--
-- Facility Protection Group Table
--
cmFacProtGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmFacProtGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to the Facility Protection Groups.
Entries can be created/deleted in this table by management
application action."
::= { cmProtObjects 1 }
cmFacProtGroupEntry OBJECT-TYPE
SYNTAX CmFacProtGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information applicable to a particular
Protection Group."
INDEX { neIndex, shelfIndex, slotIndex, cmFacProtGroupIndex }
::= { cmFacProtGroupTable 1 }
CmFacProtGroupEntry ::= SEQUENCE {
cmFacProtGroupIndex Integer32,
cmFacProtGroupUserLabel DisplayString,
cmFacProtGroupSwitchMode CmProtSwitchMode,
cmFacProtGroupRevertive TruthValue,
cmFacProtGroupWaitToRestore Integer32,
cmFacProtGroupDirection CmProtSwitchDirection,
cmFacProtGroupWorkPort VariablePointer,
cmFacProtGroupProtPort VariablePointer,
cmFacProtGroupStatus CmProtGroupStatus,
cmFacProtGroupAction CmProtSwitchAction,
cmFacProtGroupStorageType StorageType,
cmFacProtGroupRowStatus RowStatus,
cmFacProtGroupMacAddress MacAddress
}
cmFacProtGroupIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index value associated with the Facility Protection Group."
::= { cmFacProtGroupEntry 1 }
cmFacProtGroupUserLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User Label associated with the Facility Protection Group."
::= { cmFacProtGroupEntry 2 }
cmFacProtGroupSwitchMode OBJECT-TYPE
SYNTAX CmProtSwitchMode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Facility Protection Group's Protection Switch Mode."
::= { cmFacProtGroupEntry 3 }
cmFacProtGroupRevertive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Whether the Facility Protection is revertive or not.
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'."
::= { cmFacProtGroupEntry 4 }
cmFacProtGroupWaitToRestore OBJECT-TYPE
SYNTAX Integer32 (1..60|0)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time in minutes to wait before reverting to Working facility
in case of cmFacProtGroupRevertive set to revertive.
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'."
::= { cmFacProtGroupEntry 5 }
cmFacProtGroupDirection OBJECT-TYPE
SYNTAX CmProtSwitchDirection
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Supported Protection Group Switch direction.
This object is not applicable for cmFacProtGroupSwitchMode 'dualactiverx'."
::= { cmFacProtGroupEntry 6 }
cmFacProtGroupWorkPort OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Facility Protection Group exists between 2 facilities (ports).
This object represents the WORKING facility Port."
::= { cmFacProtGroupEntry 7 }
cmFacProtGroupProtPort OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object
represents the PROTECT facility Network Element Port when
cmFacProtGroupSwitchMode is oneplusone. In the case of
dualactiverx, this represents the second active port."
::= { cmFacProtGroupEntry 8 }
cmFacProtGroupStatus OBJECT-TYPE
SYNTAX CmProtGroupStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the PROTECTION group status."
::= { cmFacProtGroupEntry 9 }
cmFacProtGroupAction OBJECT-TYPE
SYNTAX CmProtSwitchAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User initiated protection switch action."
::= { cmFacProtGroupEntry 10 }
cmFacProtGroupStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of storage configured for this entry."
::= { cmFacProtGroupEntry 11 }
cmFacProtGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of cmFacProtGroupRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
cmFacProtGroupRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The cmFacProtGroupRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { cmFacProtGroupEntry 12 }
cmFacProtGroupMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object allows retrieval of the Mac Address of the PROTECTION group."
::= { cmFacProtGroupEntry 13 }
--
-- Facility Protection Unit Table
--
cmFacProtUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmFacProtUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to the Facility Protection
Units."
::= { cmProtObjects 2 }
cmFacProtUnitEntry OBJECT-TYPE
SYNTAX CmFacProtUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information applicable to a particular
Protection Unit."
INDEX { neIndex, shelfIndex, slotIndex, cmFacProtGroupIndex, cmFacProtUnitIndex }
::= { cmFacProtUnitTable 1 }
CmFacProtUnitEntry ::= SEQUENCE {
cmFacProtUnitIndex Integer32,
cmFacProtUnitType CmProtUnitType,
cmFacProtUnitState CmProtUnitState,
cmFacProtUnitPort VariablePointer
}
cmFacProtUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index value associated with the Facility Protection Unit."
::= { cmFacProtUnitEntry 1 }
cmFacProtUnitType OBJECT-TYPE
SYNTAX CmProtUnitType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Facility Protection Unit's Type, i.e. whether working or protect."
::= { cmFacProtUnitEntry 2 }
cmFacProtUnitState OBJECT-TYPE
SYNTAX CmProtUnitState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Facility Protection Unit's State, i.e. whether active or standby."
::= { cmFacProtUnitEntry 3 }
cmFacProtUnitPort OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Facility Protection Unit's points to a facility (port).
This object represents the facility Network Element port."
::= { cmFacProtUnitEntry 4 }
--
-- Multiplex Section Protection Group Table
--
cmMSPGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmMSPGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to the Multiplex Section Protection Groups.
Entries can be created/deleted in this table by management
application action."
::= { cmProtObjects 3 }
cmMSPGroupEntry OBJECT-TYPE
SYNTAX CmMSPGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information applicable to a particular
Protection Group."
INDEX { neIndex, cmMSPGroupIndex }
::= { cmMSPGroupTable 1 }
CmMSPGroupEntry ::= SEQUENCE {
cmMSPGroupIndex Integer32,
cmMSPGroupUserLabel DisplayString,
cmMSPGroupSwitchMode CmProtSwitchMode,
cmMSPGroupRevertive TruthValue,
cmMSPGroupWaitToRestore Integer32,
cmMSPGroupB2DEGTrigger TruthValue,
cmMSPGroupDirection CmProtSwitchDirection,
cmMSPGroupWorkPort VariablePointer,
cmMSPGroupProtPort VariablePointer,
cmMSPGroupStatus CmProtGroupStatus,
cmMSPGroupAction CmProtSwitchAction,
cmMSPGroupStorageType StorageType,
cmMSPGroupRowStatus RowStatus,
cmMSPGroupMacAddress MacAddress
}
cmMSPGroupIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index value associated with the Multiplex Section Protection Group."
::= { cmMSPGroupEntry 1 }
cmMSPGroupUserLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User Label associated with the Multiplex Section Protection Group."
::= { cmMSPGroupEntry 2 }
cmMSPGroupSwitchMode OBJECT-TYPE
SYNTAX CmProtSwitchMode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Multiplex Section Protection Group's Protection Switch Mode."
::= { cmMSPGroupEntry 3 }
cmMSPGroupRevertive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Whether the Multiplex Section Protection is revertive or not.
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'."
::= { cmMSPGroupEntry 4 }
cmMSPGroupWaitToRestore OBJECT-TYPE
SYNTAX Integer32 (1..60|0)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time in minutes to wait before reverting to Working facility
in case of cmMSPGroupRevertive set to revertive.
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'."
::= { cmMSPGroupEntry 5 }
cmMSPGroupB2DEGTrigger OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"B2DEG is trigger of MSP or not."
::= { cmMSPGroupEntry 6 }
cmMSPGroupDirection OBJECT-TYPE
SYNTAX CmProtSwitchDirection
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Supported Protection Group Switch direction.
This object is not applicable for cmMSPGroupSwitchMode 'dualactiverx'."
::= { cmMSPGroupEntry 7 }
cmMSPGroupWorkPort OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Multiplex Section Protection Group exists between 2 facilities (ports).
This object represents the WORKING facility Port."
::= { cmMSPGroupEntry 8 }
cmMSPGroupProtPort OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object
represents the PROTECT facility Network Element Port when
cmMSPGroupSwitchMode is oneplusone. In the case of
dualactiverx, this represents the second active port."
::= { cmMSPGroupEntry 9 }
cmMSPGroupStatus OBJECT-TYPE
SYNTAX CmProtGroupStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the PROTECTION group status."
::= { cmMSPGroupEntry 10 }
cmMSPGroupAction OBJECT-TYPE
SYNTAX CmProtSwitchAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User initiated protection switch action."
::= { cmMSPGroupEntry 11 }
cmMSPGroupStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of storage configured for this entry."
::= { cmMSPGroupEntry 12 }
cmMSPGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of cmMSPGroupRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
cmMSPGroupRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The cmMSPGroupRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { cmMSPGroupEntry 13 }
cmMSPGroupMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object allows retrieval of the Mac Address of the PROTECTION group."
::= { cmMSPGroupEntry 14 }
--
-- Multiplex Section Protection Unit Table
--
cmMSPUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF CmMSPUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of entries corresponding to the Multiplex Section Protection
Units."
::= { cmProtObjects 4 }
cmMSPUnitEntry OBJECT-TYPE
SYNTAX CmMSPUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information applicable to a particular
Protection Unit."
INDEX { neIndex, cmMSPGroupIndex, cmMSPUnitIndex }
::= { cmMSPUnitTable 1 }
CmMSPUnitEntry ::= SEQUENCE {
cmMSPUnitIndex Integer32,
cmMSPUnitType CmProtUnitType,
cmMSPUnitState CmProtUnitState,
cmMSPUnitPort VariablePointer
}
cmMSPUnitIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index value associated with the Multiplex Section Protection Unit."
::= { cmMSPUnitEntry 1 }
cmMSPUnitType OBJECT-TYPE
SYNTAX CmProtUnitType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplex Section Protection Unit's Type, i.e. whether working or protect."
::= { cmMSPUnitEntry 2 }
cmMSPUnitState OBJECT-TYPE
SYNTAX CmProtUnitState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplex Section Protection Unit's State, i.e. whether active or standby."
::= { cmMSPUnitEntry 3 }
cmMSPUnitPort OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Facility Protection Unit's points to a facility (port).
This object represents the facility Network Element port."
::= { cmMSPUnitEntry 4 }
--
-- Conformance
--
cmProtCompliances OBJECT IDENTIFIER ::= {cmProtConformance 1}
cmProtGroups OBJECT IDENTIFIER ::= {cmProtConformance 2}
cmProtCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the CM Prot
group."
MODULE -- this module
MANDATORY-GROUPS {
cmProtObjectGroup, cmMSProtObjectGroup
}
::= { cmProtCompliances 1 }
cmProtObjectGroup OBJECT-GROUP
OBJECTS {
cmFacProtGroupIndex, cmFacProtGroupUserLabel, cmFacProtGroupSwitchMode,
cmFacProtGroupRevertive, cmFacProtGroupWaitToRestore,
cmFacProtGroupDirection, cmFacProtGroupWorkPort,
cmFacProtGroupProtPort, cmFacProtGroupStatus, cmFacProtGroupAction,
cmFacProtGroupStorageType, cmFacProtGroupRowStatus,
cmFacProtGroupMacAddress,
cmFacProtUnitIndex, cmFacProtUnitType, cmFacProtUnitState,
cmFacProtUnitPort
}
STATUS current
DESCRIPTION
"A collection of objects used to manage the Protection Object group."
::= { cmProtGroups 1 }
cmMSProtObjectGroup OBJECT-GROUP
OBJECTS {
cmMSPGroupIndex, cmMSPGroupUserLabel,
cmMSPGroupSwitchMode, cmMSPGroupRevertive,
cmMSPGroupWaitToRestore, cmMSPGroupB2DEGTrigger,
cmMSPGroupDirection, cmMSPGroupWorkPort,
cmMSPGroupProtPort, cmMSPGroupStatus,
cmMSPGroupAction, cmMSPGroupStorageType,
cmMSPGroupRowStatus, cmMSPGroupMacAddress,
cmMSPUnitIndex, cmMSPUnitType,
cmMSPUnitState, cmMSPUnitPort
}
STATUS current
DESCRIPTION
"A collection of objects used to manage the Multiplex
Section Protection Object group."
::= { cmProtGroups 2 }
END