Initial commit
This commit is contained in:
		
							
								
								
									
										503
									
								
								MIBS/adva/F3-PBB-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										503
									
								
								MIBS/adva/F3-PBB-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,503 @@
 | 
			
		||||
F3-PBB-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
IMPORTS
 | 
			
		||||
        MODULE-COMPLIANCE, OBJECT-GROUP 
 | 
			
		||||
                FROM SNMPv2-CONF
 | 
			
		||||
        MODULE-IDENTITY, OBJECT-TYPE, Integer32
 | 
			
		||||
                FROM SNMPv2-SMI
 | 
			
		||||
        DisplayString, TruthValue, MacAddress, VariablePointer
 | 
			
		||||
                FROM SNMPv2-TC
 | 
			
		||||
        cmEthernetAccPortEntry, cmEthernetNetPortEntry, cmFlowEntry,
 | 
			
		||||
        FlowTagControl
 | 
			
		||||
                FROM CM-FACILITY-MIB
 | 
			
		||||
        ipManagementTunnelEntry
 | 
			
		||||
                FROM CM-IP-MIB
 | 
			
		||||
        PerfCounter64
 | 
			
		||||
             FROM  CM-COMMON-MIB
 | 
			
		||||
        cmEthernetNetPortStatsEntry, cmEthernetNetPortHistoryEntry
 | 
			
		||||
             FROM  CM-PERFORMANCE-MIB
 | 
			
		||||
        fsp150cm
 | 
			
		||||
             FROM  ADVA-MIB;
 | 
			
		||||
 | 
			
		||||
f3PBBMIB MODULE-IDENTITY
 | 
			
		||||
    LAST-UPDATED        "201210080000Z"
 | 
			
		||||
    ORGANIZATION    "ADVA Optical Networking"
 | 
			
		||||
    CONTACT-INFO
 | 
			
		||||
            "        Raghav Trivedi
 | 
			
		||||
                     ADVA Optical Networking, Inc.
 | 
			
		||||
                Tel: +1 972 759-1239
 | 
			
		||||
             E-mail: rtrivedi@advaoptical.com
 | 
			
		||||
             Postal: 2301 N. Greenville Ave. #300
 | 
			
		||||
                     Richardson, TX USA 75082"
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This module defines the Facility MIB definitions used by 
 | 
			
		||||
             the F3 (FSP150CM/CC) product lines.  
 | 
			
		||||
             Copyright (C) ADVA Optical Networking."
 | 
			
		||||
    REVISION        "201210080000Z"
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
             "Notes from release 201210080000Z. "
 | 
			
		||||
    ::= {fsp150cm 21}
 | 
			
		||||
-- 
 | 
			
		||||
-- OID definitions
 | 
			
		||||
-- 
 | 
			
		||||
f3PBBConfigObjects            OBJECT IDENTIFIER ::= {f3PBBMIB 1}
 | 
			
		||||
f3PBBPerformanceObjects       OBJECT IDENTIFIER ::= {f3PBBMIB 2}
 | 
			
		||||
f3PBBConformance              OBJECT IDENTIFIER ::= {f3PBBMIB 3}
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
--  f3PbbEthernetAccPortTable
 | 
			
		||||
--
 | 
			
		||||
f3PbbEthernetAccPortTable  OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF F3PbbEthernetAccPortEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A list of entries corresponding to PBB function on the net port"
 | 
			
		||||
    ::= { f3PBBConfigObjects 1 }
 | 
			
		||||
 | 
			
		||||
f3PbbEthernetAccPortEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX      F3PbbEthernetAccPortEntry 
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A conceptual row in the f3PbbEthernetAccPortTable."
 | 
			
		||||
    AUGMENTS { cmEthernetAccPortEntry }
 | 
			
		||||
    ::= { f3PbbEthernetAccPortTable 1 }
 | 
			
		||||
    
 | 
			
		||||
F3PbbEthernetAccPortEntry ::= SEQUENCE {  
 | 
			
		||||
    f3PbbEthernetAccPortITagLoopbackMask                INTEGER,
 | 
			
		||||
    f3PbbEthernetAccPortITagLoopback1                   DisplayString,
 | 
			
		||||
    f3PbbEthernetAccPortITagLoopback2                   DisplayString,
 | 
			
		||||
    f3PbbEthernetAccPortITagLoopback3                   DisplayString   
 | 
			
		||||
}
 | 
			
		||||
    
 | 
			
		||||
f3PbbEthernetAccPortITagLoopbackMask OBJECT-TYPE
 | 
			
		||||
    SYNTAX     INTEGER
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
             "This object allows to specify which itag loopback has been enabled.
 | 
			
		||||
             1: Itag 1 loopback enabled, 2: Itag 2 loopback enabled, 4: Itag 4 loopback enabled."
 | 
			
		||||
     ::= { f3PbbEthernetAccPortEntry 1 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetAccPortITagLoopback1 OBJECT-TYPE
 | 
			
		||||
    SYNTAX  DisplayString
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This object allows specification of the Itag 1 to be looped back when port is in
 | 
			
		||||
            vlan(terminal/facility) loopback configuration. This is valid only if the
 | 
			
		||||
            corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set.  The value
 | 
			
		||||
            to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority. 
 | 
			
		||||
            If Y is specified as a *, all Priorities (0 to 7) are looped back."
 | 
			
		||||
     ::= { f3PbbEthernetAccPortEntry 2 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetAccPortITagLoopback2 OBJECT-TYPE
 | 
			
		||||
    SYNTAX  DisplayString
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This object allows specification of the Itag 2 to be looped back when port is in
 | 
			
		||||
            vlan(terminal/facility) loopback configuration. This is valid only if the
 | 
			
		||||
            corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set.  The value
 | 
			
		||||
            to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority. 
 | 
			
		||||
            If Y is specified as a *, all Priorities (0 to 7) are looped back."
 | 
			
		||||
     ::= { f3PbbEthernetAccPortEntry 3 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetAccPortITagLoopback3 OBJECT-TYPE
 | 
			
		||||
    SYNTAX  DisplayString
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This object allows specification of the Itag 3 to be looped back when port is in
 | 
			
		||||
            vlan(terminal/facility) loopback configuration. This is valid only if the
 | 
			
		||||
            corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set.  The value
 | 
			
		||||
            to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority. 
 | 
			
		||||
            If Y is specified as a *, all Priorities (0 to 7) are looped back."
 | 
			
		||||
     ::= { f3PbbEthernetAccPortEntry 4 }
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
--  f3PbbEthernetNetPortTable
 | 
			
		||||
--
 | 
			
		||||
f3PbbEthernetNetPortTable  OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF F3PbbEthernetNetPortEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A list of entries corresponding to PBB function on the net port"
 | 
			
		||||
    ::= { f3PBBConfigObjects 2 }
 | 
			
		||||
 | 
			
		||||
f3PbbEthernetNetPortEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX      F3PbbEthernetNetPortEntry 
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A conceptual row in the f3PbbEthernetNetPortTable."
 | 
			
		||||
    AUGMENTS { cmEthernetNetPortEntry }
 | 
			
		||||
    ::= { f3PbbEthernetNetPortTable 1 }
 | 
			
		||||
    
 | 
			
		||||
F3PbbEthernetNetPortEntry ::= SEQUENCE {
 | 
			
		||||
    f3PbbEthernetNetPortBackboneMacAddress              MacAddress,    
 | 
			
		||||
    f3PbbEthernetNetPortITagLoopbackMask                INTEGER,
 | 
			
		||||
    f3PbbEthernetNetPortITagLoopback1                   DisplayString,
 | 
			
		||||
    f3PbbEthernetNetPortITagLoopback2                   DisplayString,
 | 
			
		||||
    f3PbbEthernetNetPortITagLoopback3                   DisplayString   
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
f3PbbEthernetNetPortBackboneMacAddress OBJECT-TYPE
 | 
			
		||||
    SYNTAX     MacAddress
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
             "This object is mac address of backbone network port." 
 | 
			
		||||
     ::= { f3PbbEthernetNetPortEntry 1 }
 | 
			
		||||
    
 | 
			
		||||
f3PbbEthernetNetPortITagLoopbackMask OBJECT-TYPE
 | 
			
		||||
    SYNTAX     INTEGER
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
             "This object allows to specify which itag loopback has been enabled.
 | 
			
		||||
             1: Itag 1 loopback enabled, 2: Itag 2 loopback enabled, 4: Itag 4 loopback enabled."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortEntry 2 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetNetPortITagLoopback1 OBJECT-TYPE
 | 
			
		||||
    SYNTAX  DisplayString
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This object allows specification of the Itag 1 to be looped back when port is in
 | 
			
		||||
            vlan(terminal/facility) loopback configuration. This is valid only if the
 | 
			
		||||
            corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set.  The value
 | 
			
		||||
            to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority. 
 | 
			
		||||
            If Y is specified as a *, all Priorities (0 to 7) are looped back."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortEntry 3 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetNetPortITagLoopback2 OBJECT-TYPE
 | 
			
		||||
    SYNTAX  DisplayString
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This object allows specification of the Itag 2 to be looped back when port is in
 | 
			
		||||
            vlan(terminal/facility) loopback configuration. This is valid only if the
 | 
			
		||||
            corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set.  The value
 | 
			
		||||
            to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority. 
 | 
			
		||||
            If Y is specified as a *, all Priorities (0 to 7) are looped back."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortEntry 4 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetNetPortITagLoopback3 OBJECT-TYPE
 | 
			
		||||
    SYNTAX  DisplayString
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This object allows specification of the Itag 3 to be looped back when port is in
 | 
			
		||||
            vlan(terminal/facility) loopback configuration. This is valid only if the
 | 
			
		||||
            corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set.  The value
 | 
			
		||||
            to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority. 
 | 
			
		||||
            If Y is specified as a *, all Priorities (0 to 7) are looped back."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortEntry 5 }
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
--  f3PbbFlowTable
 | 
			
		||||
--
 | 
			
		||||
f3PbbFlowTable  OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF F3PbbFlowEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A list of entries corresponding to PBB function on the flow"
 | 
			
		||||
    ::= { f3PBBConfigObjects 3 }
 | 
			
		||||
 | 
			
		||||
f3PbbFlowEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX      F3PbbFlowEntry 
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A conceptual row in the f3PbbFlowTable."
 | 
			
		||||
    AUGMENTS { cmFlowEntry }
 | 
			
		||||
    ::= { f3PbbFlowTable 1 }
 | 
			
		||||
    
 | 
			
		||||
F3PbbFlowEntry ::= SEQUENCE {
 | 
			
		||||
    f3PbbFlowITagControl                     FlowTagControl,
 | 
			
		||||
    f3PbbFlowITagISID                        Integer32,
 | 
			
		||||
    f3PbbFlowITagPriority                    Integer32,
 | 
			
		||||
    f3PbbFlowBackboneMacDestinationEnabled   TruthValue,
 | 
			
		||||
    f3PbbFlowBackboneMacDestinationAddress   MacAddress,
 | 
			
		||||
    f3PbbFlowA2NPbbCapableFlag               TruthValue
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
f3PbbFlowITagControl  OBJECT-TYPE
 | 
			
		||||
    SYNTAX     FlowTagControl
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
         "This object allows specification of the tag management 
 | 
			
		||||
          operation on the I-TAG.  Supported types are 'none', 'push', and 'pushisid'.
 | 
			
		||||
          and it must be none while ctagcontrol or stagcontrol is not none."
 | 
			
		||||
     ::= { f3PbbFlowEntry 1 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbFlowITagISID OBJECT-TYPE 
 | 
			
		||||
    SYNTAX     Integer32 (256..16777214)
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
         "This object is used to specify the ITagISID. Its rang from 256 to 16777214."
 | 
			
		||||
     ::= { f3PbbFlowEntry 2 }
 | 
			
		||||
 | 
			
		||||
f3PbbFlowITagPriority OBJECT-TYPE 
 | 
			
		||||
    SYNTAX     Integer32 (0..7)
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
         "This object is used to specify the priority of ITag. Its rang from 0 to 7."
 | 
			
		||||
     ::= { f3PbbFlowEntry 3 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbFlowBackboneMacDestinationEnabled  OBJECT-TYPE
 | 
			
		||||
    SYNTAX     TruthValue
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
         "This object indicates whether can assign BMAC value.
 | 
			
		||||
          When enabled, user can assign a  unicast BMAC as B_DA for this EVC
 | 
			
		||||
          When disabled, 01-1E-83-<I-SID> will be used as B-DA."
 | 
			
		||||
     ::= { f3PbbFlowEntry 4 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbFlowBackboneMacDestinationAddress OBJECT-TYPE
 | 
			
		||||
    SYNTAX     MacAddress
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
         "Customer can configure the backbone MAC destination address, the
 | 
			
		||||
         default value is 01-1E-83-<I-SID>."
 | 
			
		||||
    ::= { f3PbbFlowEntry 5 }
 | 
			
		||||
    
 | 
			
		||||
f3PbbFlowA2NPbbCapableFlag  OBJECT-TYPE
 | 
			
		||||
    SYNTAX     TruthValue
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
         "When it is false, Drop PBB frames in the A2N direction (FPGA function),
 | 
			
		||||
         Allow to PUSH I-TAG on this flow;
 | 
			
		||||
         When A2NPbbCapableFlag is TRUE,
 | 
			
		||||
         Pass PBB frames in the A2N direction (FPGA function), Software allow PUSH I-TAG on this flow(normal)
 | 
			
		||||
         will not allow to PUSH S-TAG on this flow, will not allow to PUSH C-TAG on this flow,
 | 
			
		||||
         Software will allow to PUSH C-TAG/S-TAG on this flow."
 | 
			
		||||
     ::= { f3PbbFlowEntry 6 }
 | 
			
		||||
     
 | 
			
		||||
--
 | 
			
		||||
--  f3PbbIpManagementTunnelTable
 | 
			
		||||
--
 | 
			
		||||
f3PbbIpManagementTunnelTable  OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF F3PbbIpManagementTunnelEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A list of entries corresponding to PBB function on the mngt tunnel"
 | 
			
		||||
    ::= { f3PBBConfigObjects 4 }
 | 
			
		||||
 | 
			
		||||
f3PbbIpManagementTunnelEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX      F3PbbIpManagementTunnelEntry 
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A conceptual row in the f3PbbIpManagementTunnelTable."
 | 
			
		||||
    AUGMENTS { ipManagementTunnelEntry }
 | 
			
		||||
    ::= { f3PbbIpManagementTunnelTable 1 }
 | 
			
		||||
    
 | 
			
		||||
F3PbbIpManagementTunnelEntry ::= SEQUENCE {
 | 
			
		||||
    f3PbbIpManagementTunnelItagEnabled         TruthValue,
 | 
			
		||||
    f3PbbIpManagementTunnelISID                Integer32,
 | 
			
		||||
    f3PbbIpManagementTunnelIPriority           Integer32,
 | 
			
		||||
    f3PbbIpManagementTunnelBackboneMacDestinationEnabled         TruthValue,
 | 
			
		||||
    f3PbbIpManagementTunnelBackboneMacDestinationAddress         MacAddress
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
f3PbbIpManagementTunnelItagEnabled OBJECT-TYPE
 | 
			
		||||
    SYNTAX     TruthValue 
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS   current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
       "This object ITAG whether enabled, It is Enabled only When management tunnel type is ISID based.
 | 
			
		||||
        By default it is disabled"
 | 
			
		||||
    ::= { f3PbbIpManagementTunnelEntry 1 }
 | 
			
		||||
    
 | 
			
		||||
f3PbbIpManagementTunnelISID OBJECT-TYPE
 | 
			
		||||
    SYNTAX     Integer32(256..16777214)
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS   current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
       "Only applicable when iTagEnabled =  enabled (ISID is shown to user, but in IFM data type here is ITAG)."
 | 
			
		||||
    ::= { f3PbbIpManagementTunnelEntry 2 }
 | 
			
		||||
    
 | 
			
		||||
f3PbbIpManagementTunnelIPriority OBJECT-TYPE
 | 
			
		||||
    SYNTAX     Integer32(0..7)
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS   current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
       "Only applicable when iTagEnabled =  enabled (ISID is shown to user, but in IFM data type here is ITAG, no use at present)."
 | 
			
		||||
    ::= { f3PbbIpManagementTunnelEntry 3 }
 | 
			
		||||
 | 
			
		||||
f3PbbIpManagementTunnelBackboneMacDestinationEnabled OBJECT-TYPE
 | 
			
		||||
    SYNTAX     TruthValue 
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS   current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
       "When enabled, we will use provisioned B-MAC for ARP and for management packets.
 | 
			
		||||
        When disabled, we will use backbone group MAC address for ARP and get B-DA from ARP response
 | 
			
		||||
        By default, it is disabled"
 | 
			
		||||
    ::= { f3PbbIpManagementTunnelEntry 4 }
 | 
			
		||||
 | 
			
		||||
f3PbbIpManagementTunnelBackboneMacDestinationAddress OBJECT-TYPE
 | 
			
		||||
    SYNTAX     MacAddress 
 | 
			
		||||
    MAX-ACCESS read-write
 | 
			
		||||
    STATUS   current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
       "User must set a valid MAC address, Only applicable when iTagEnabled =  enabled
 | 
			
		||||
        By default, it is 00:00:00:00:00:00"
 | 
			
		||||
    ::= { f3PbbIpManagementTunnelEntry 5 }
 | 
			
		||||
    
 | 
			
		||||
--
 | 
			
		||||
-- PBB Net Port Statistics Table
 | 
			
		||||
--
 | 
			
		||||
f3PbbEthernetNetPortStatsTable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF F3PbbEthernetNetPortStatsEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A collection of pbb Ethernet Network Port related statistics.  
 | 
			
		||||
             These reflect the current data."
 | 
			
		||||
    ::= { f3PBBPerformanceObjects 1 }
 | 
			
		||||
 | 
			
		||||
f3PbbEthernetNetPortStatsEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX      F3PbbEthernetNetPortStatsEntry 
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A conceptual row in the f3PbbEthernetNetPortStatsTable.
 | 
			
		||||
             Entries exist in this table for each Ethernet interface/port."
 | 
			
		||||
    AUGMENTS { cmEthernetNetPortStatsEntry }
 | 
			
		||||
    ::= { f3PbbEthernetNetPortStatsTable 1 }
 | 
			
		||||
 | 
			
		||||
F3PbbEthernetNetPortStatsEntry ::= SEQUENCE {
 | 
			
		||||
    f3PbbEthernetNetPortStatsPbbUniBdaDiscard      PerfCounter64,
 | 
			
		||||
    f3PbbEthernetNetPortStatsPbbGroupBdaDiscard    PerfCounter64
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
f3PbbEthernetNetPortStatsPbbUniBdaDiscard OBJECT-TYPE
 | 
			
		||||
     SYNTAX     PerfCounter64
 | 
			
		||||
     MAX-ACCESS read-only
 | 
			
		||||
     STATUS     current
 | 
			
		||||
     DESCRIPTION
 | 
			
		||||
         "Number of PBB frames (BDA is not backbone group MAC) 
 | 
			
		||||
         discarded due to receive BDA which is not matching the 
 | 
			
		||||
         port's PBB MAC address when port is non-promiscuous mode."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortStatsEntry 1 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetNetPortStatsPbbGroupBdaDiscard OBJECT-TYPE
 | 
			
		||||
     SYNTAX     PerfCounter64
 | 
			
		||||
     MAX-ACCESS read-only
 | 
			
		||||
     STATUS     current
 | 
			
		||||
     DESCRIPTION
 | 
			
		||||
         "Number of PBB frames discarded due to mismatch of I-SID in I-TAG and I-SID 
 | 
			
		||||
         in backbone group MAC in the B-DA when port is non-promiscuous mode."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortStatsEntry 2 }
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
-- PBB Net Port History Statistics Table
 | 
			
		||||
--
 | 
			
		||||
f3PbbEthernetNetPortHistoryStatsTable OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF F3PbbEthernetNetPortHistoryStatsEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A collection of pbb Ethernet Network Port related statistics.  
 | 
			
		||||
             These reflect the current data."
 | 
			
		||||
    ::= { f3PBBPerformanceObjects 2 }
 | 
			
		||||
 | 
			
		||||
f3PbbEthernetNetPortHistoryStatsEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX      F3PbbEthernetNetPortHistoryStatsEntry 
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A conceptual row in the f3PbbEthernetNetPortHistoryStatsTable.
 | 
			
		||||
             Entries exist in this table for each Ethernet interface/port."
 | 
			
		||||
    AUGMENTS { cmEthernetNetPortHistoryEntry }
 | 
			
		||||
    ::= { f3PbbEthernetNetPortHistoryStatsTable 1 }
 | 
			
		||||
 | 
			
		||||
F3PbbEthernetNetPortHistoryStatsEntry ::= SEQUENCE {
 | 
			
		||||
    f3PbbEthernetNetPortHistoryStatsPbbUniBdaDiscard      PerfCounter64,
 | 
			
		||||
    f3PbbEthernetNetPortHistoryStatsPbbGroupBdaDiscard    PerfCounter64
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
f3PbbEthernetNetPortHistoryStatsPbbUniBdaDiscard OBJECT-TYPE
 | 
			
		||||
     SYNTAX     PerfCounter64
 | 
			
		||||
     MAX-ACCESS read-only
 | 
			
		||||
     STATUS     current
 | 
			
		||||
     DESCRIPTION
 | 
			
		||||
         "Number of PBB frames (BDA is not backbone group MAC) 
 | 
			
		||||
         discarded due to receive BDA which is not matching the 
 | 
			
		||||
         port's PBB MAC address when port is non-promiscuous mode."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortHistoryStatsEntry 1 }
 | 
			
		||||
     
 | 
			
		||||
f3PbbEthernetNetPortHistoryStatsPbbGroupBdaDiscard OBJECT-TYPE
 | 
			
		||||
     SYNTAX     PerfCounter64
 | 
			
		||||
     MAX-ACCESS read-only
 | 
			
		||||
     STATUS     current
 | 
			
		||||
     DESCRIPTION
 | 
			
		||||
         "Number of PBB frames discarded due to mismatch of I-SID in I-TAG and I-SID 
 | 
			
		||||
         in backbone group MAC in the B-DA when port is non-promiscuous mode."
 | 
			
		||||
     ::= { f3PbbEthernetNetPortHistoryStatsEntry 2 }
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
--Conformance
 | 
			
		||||
--
 | 
			
		||||
f3PBBCompliances      OBJECT IDENTIFIER ::= {f3PBBConformance 1}
 | 
			
		||||
f3PBBGroups           OBJECT IDENTIFIER ::= {f3PBBConformance 2}
 | 
			
		||||
 | 
			
		||||
f3PBBCompliance MODULE-COMPLIANCE
 | 
			
		||||
    STATUS  current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "Describes the requirements for conformance to the PBB Object
 | 
			
		||||
             group."
 | 
			
		||||
    MODULE  -- this module
 | 
			
		||||
        MANDATORY-GROUPS {
 | 
			
		||||
              f3PbbConfigGroup, f3PbbStatsGroup
 | 
			
		||||
        }
 | 
			
		||||
    ::= { f3PBBCompliances 1 }
 | 
			
		||||
 | 
			
		||||
f3PbbConfigGroup OBJECT-GROUP
 | 
			
		||||
    OBJECTS {
 | 
			
		||||
        f3PbbEthernetAccPortITagLoopbackMask, f3PbbEthernetAccPortITagLoopback1,
 | 
			
		||||
        f3PbbEthernetAccPortITagLoopback2, f3PbbEthernetAccPortITagLoopback3,
 | 
			
		||||
        
 | 
			
		||||
        f3PbbEthernetNetPortBackboneMacAddress, f3PbbEthernetNetPortITagLoopbackMask,
 | 
			
		||||
        f3PbbEthernetNetPortITagLoopback1, f3PbbEthernetNetPortITagLoopback2,
 | 
			
		||||
        f3PbbEthernetNetPortITagLoopback3,
 | 
			
		||||
        
 | 
			
		||||
        f3PbbFlowITagControl, f3PbbFlowITagISID,
 | 
			
		||||
        f3PbbFlowITagPriority, f3PbbFlowBackboneMacDestinationEnabled,
 | 
			
		||||
        f3PbbFlowBackboneMacDestinationAddress, f3PbbFlowA2NPbbCapableFlag,
 | 
			
		||||
        
 | 
			
		||||
        f3PbbIpManagementTunnelItagEnabled, f3PbbIpManagementTunnelISID,
 | 
			
		||||
        f3PbbIpManagementTunnelIPriority, f3PbbIpManagementTunnelBackboneMacDestinationEnabled,
 | 
			
		||||
        f3PbbIpManagementTunnelBackboneMacDestinationAddress
 | 
			
		||||
    }
 | 
			
		||||
    STATUS  current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A collection of objects used to manage the F3 PBB Functionality
 | 
			
		||||
             ."
 | 
			
		||||
    ::= { f3PBBGroups 1 }
 | 
			
		||||
 | 
			
		||||
f3PbbStatsGroup OBJECT-GROUP
 | 
			
		||||
    OBJECTS {
 | 
			
		||||
        f3PbbEthernetNetPortStatsPbbUniBdaDiscard, f3PbbEthernetNetPortStatsPbbGroupBdaDiscard,	
 | 
			
		||||
        
 | 
			
		||||
        f3PbbEthernetNetPortHistoryStatsPbbUniBdaDiscard, f3PbbEthernetNetPortHistoryStatsPbbGroupBdaDiscard
 | 
			
		||||
    }
 | 
			
		||||
    STATUS  current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A collection of objects used to manage the F3 PBB Functionality
 | 
			
		||||
            ."
 | 
			
		||||
    ::= { f3PBBGroups 2 }
 | 
			
		||||
 | 
			
		||||
END
 | 
			
		||||
		Reference in New Issue
	
	Block a user