Initial commit
This commit is contained in:
626
MIBS/allied/AT-ENVMON-MIB
Normal file
626
MIBS/allied/AT-ENVMON-MIB
Normal file
@ -0,0 +1,626 @@
|
||||
-- ============================================================================
|
||||
-- AT-ENVMON.MIB, Allied Telesis enterprise MIB: Environment Monitoring
|
||||
--
|
||||
-- Copied from ATR-ENVMON.MIB of pre 2.9.1 release
|
||||
--
|
||||
-- Copyright (c) 2006 by Allied Telesis, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- ============================================================================
|
||||
|
||||
AT-ENVMON-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE,
|
||||
Unsigned32,
|
||||
enterprises
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
TruthValue,
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
|
||||
ifIndex
|
||||
FROM IF-MIB
|
||||
|
||||
DisplayStringUnsized
|
||||
FROM AT-SMI-MIB
|
||||
|
||||
sysinfo
|
||||
FROM AT-SYSINFO-MIB
|
||||
;
|
||||
|
||||
envMon MODULE-IDENTITY
|
||||
LAST-UPDATED "200603070000Z"
|
||||
ORGANIZATION "Allied Telesis, Inc"
|
||||
CONTACT-INFO
|
||||
"http://www.alliedtelesis.com"
|
||||
DESCRIPTION
|
||||
"The AT Environment Monitoring MIB for managing and
|
||||
reporting data relating to voltage rails, fan speeds,
|
||||
temperature sensors and power supply units."
|
||||
|
||||
REVISION "200603070000Z"
|
||||
DESCRIPTION
|
||||
"Initial Revision"
|
||||
::= { sysinfo 10 }
|
||||
|
||||
-- Textual Conventions
|
||||
|
||||
EnvMonPsbSensorType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the type of a Power Supply Bay Device sensor."
|
||||
SYNTAX INTEGER {
|
||||
psbSensorTypeInvalid (0),
|
||||
fanSpeedDiscrete (1),
|
||||
temperatureDiscrete (2),
|
||||
voltageDiscrete (3) }
|
||||
|
||||
-- This section of the MIB contains new generic environment monitoring
|
||||
-- data. It relates to temperature, fanspeed, voltage and power supply
|
||||
-- bay device monitors.
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- The Environment Monitoring Fan Table
|
||||
-- ---------------------------------------------------------- --
|
||||
|
||||
envMonFanTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EnvMonFanEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of fans installed in the device that have their
|
||||
fan speeds monitored by environment monitoring hardware."
|
||||
::= { envMon 1 }
|
||||
|
||||
envMonFanEntry OBJECT-TYPE
|
||||
SYNTAX EnvMonFanEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description, current speed, lower threshold speed and
|
||||
current status of a fan."
|
||||
INDEX { envMonFanBoardIndex, envMonFanIndex }
|
||||
::= { envMonFanTable 1 }
|
||||
|
||||
EnvMonFanEntry ::=
|
||||
SEQUENCE {
|
||||
envMonFanBoardIndex
|
||||
Unsigned32,
|
||||
envMonFanIndex
|
||||
Unsigned32,
|
||||
envMonFanDescription
|
||||
DisplayStringUnsized,
|
||||
envMonFanCurrentSpeed
|
||||
Unsigned32,
|
||||
envMonFanLowerThreshold
|
||||
Unsigned32,
|
||||
envMonFanAlarm
|
||||
TruthValue
|
||||
}
|
||||
|
||||
envMonFanBoardIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the board hosting this fan in the board table."
|
||||
::= { envMonFanEntry 1 }
|
||||
|
||||
envMonFanIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The numeric identifier of this fan within the context of its host board."
|
||||
::= { envMonFanEntry 2 }
|
||||
|
||||
envMonFanDescription OBJECT-TYPE
|
||||
SYNTAX DisplayStringUnsized (SIZE (0..30))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The text description of this fan."
|
||||
::= { envMonFanEntry 3 }
|
||||
|
||||
envMonFanCurrentSpeed OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current speed of this fan in revolutions per
|
||||
minute."
|
||||
::= { envMonFanEntry 4 }
|
||||
|
||||
envMonFanLowerThreshold OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The minimum acceptable speed of the fan (in revolutions
|
||||
per minute)."
|
||||
::= { envMonFanEntry 5 }
|
||||
|
||||
envMonFanAlarm OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An indication of whether this fan is currently in an
|
||||
alarm condition. A value of TRUE indicates that its
|
||||
current speed is too low, FALSE indicates that the
|
||||
current speed is acceptable."
|
||||
::= { envMonFanEntry 6 }
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- The Environment Monitoring Voltage Table
|
||||
-- ---------------------------------------------------------- --
|
||||
|
||||
envMonVoltageTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EnvMonVoltageEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of voltage rails in the device that are
|
||||
monitored by environment monitoring hardware."
|
||||
::= { envMon 2 }
|
||||
|
||||
envMonVoltageEntry OBJECT-TYPE
|
||||
SYNTAX EnvMonVoltageEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description, current value, upper & lower threshold
|
||||
settings and current status of a voltage rail."
|
||||
INDEX { envMonVoltageBoardIndex, envMonVoltageIndex }
|
||||
::= { envMonVoltageTable 1 }
|
||||
|
||||
EnvMonVoltageEntry ::=
|
||||
SEQUENCE {
|
||||
envMonVoltageBoardIndex
|
||||
Unsigned32,
|
||||
envMonVoltageIndex
|
||||
Unsigned32,
|
||||
envMonVoltageDescription
|
||||
DisplayStringUnsized,
|
||||
envMonVoltageCurrent
|
||||
INTEGER,
|
||||
envMonVoltageUpperThreshold
|
||||
INTEGER,
|
||||
envMonVoltageLowerThreshold
|
||||
INTEGER,
|
||||
envMonVoltageAlarm
|
||||
TruthValue
|
||||
}
|
||||
|
||||
envMonVoltageBoardIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the board hosting this voltage sensor in the board table."
|
||||
::= { envMonVoltageEntry 1 }
|
||||
|
||||
envMonVoltageIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The numeric identifier of this voltage rail within the context of its host board."
|
||||
::= { envMonVoltageEntry 2 }
|
||||
|
||||
envMonVoltageDescription OBJECT-TYPE
|
||||
SYNTAX DisplayStringUnsized (SIZE (0..30))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The text description of this voltage rail."
|
||||
::= { envMonVoltageEntry 3 }
|
||||
|
||||
envMonVoltageCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current reading of this voltage rail in millivolts."
|
||||
::= { envMonVoltageEntry 4 }
|
||||
|
||||
envMonVoltageUpperThreshold OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum acceptable reading of this voltage rail in millivolts."
|
||||
::= { envMonVoltageEntry 5 }
|
||||
|
||||
envMonVoltageLowerThreshold OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The minimum acceptable reading of this voltage rail in millivolts."
|
||||
::= { envMonVoltageEntry 6 }
|
||||
|
||||
envMonVoltageAlarm OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An indication of whether this voltage rail is currently
|
||||
in an alarm condition. A value of TRUE indicates that
|
||||
its current reading is outside its threshold range,
|
||||
FALSE indicates that the current reading is acceptable."
|
||||
::= { envMonVoltageEntry 7 }
|
||||
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- The Environment Monitoring Temperature Table
|
||||
-- ---------------------------------------------------------- --
|
||||
|
||||
envMonTemperatureTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EnvMonTemperatureEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of temperature sensors in the device that are
|
||||
monitored by environment monitoring hardware."
|
||||
::= { envMon 3 }
|
||||
|
||||
envMonTemperatureEntry OBJECT-TYPE
|
||||
SYNTAX EnvMonTemperatureEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description, current value, upper threshold setting
|
||||
and current status of a temperature sensor."
|
||||
INDEX { envMonTemperatureBoardIndex, envMonTemperatureIndex }
|
||||
::= { envMonTemperatureTable 1 }
|
||||
|
||||
EnvMonTemperatureEntry ::=
|
||||
SEQUENCE {
|
||||
envMonTemperatureBoardIndex
|
||||
Unsigned32,
|
||||
envMonTemperatureIndex
|
||||
Unsigned32,
|
||||
envMonTemperatureDescription
|
||||
DisplayStringUnsized,
|
||||
envMonTemperatureCurrent
|
||||
INTEGER,
|
||||
envMonTemperatureUpperThreshold
|
||||
INTEGER,
|
||||
envMonTemperatureAlarm
|
||||
TruthValue
|
||||
}
|
||||
|
||||
envMonTemperatureBoardIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the board hosting this temperature sensor in the board table."
|
||||
::= { envMonTemperatureEntry 1 }
|
||||
|
||||
envMonTemperatureIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The numeric identifier of this temperature sensor within the context of its host board."
|
||||
::= { envMonTemperatureEntry 2 }
|
||||
|
||||
envMonTemperatureDescription OBJECT-TYPE
|
||||
SYNTAX DisplayStringUnsized (SIZE (0..30))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The text description of this temperature sensor."
|
||||
::= { envMonTemperatureEntry 3 }
|
||||
|
||||
envMonTemperatureCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current reading of this temperature sensor in tenths of a degree Celcius."
|
||||
::= { envMonTemperatureEntry 4 }
|
||||
|
||||
envMonTemperatureUpperThreshold OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum acceptable reading of this temperature
|
||||
sensor in tenths of a degree Celcius."
|
||||
::= { envMonTemperatureEntry 5 }
|
||||
|
||||
envMonTemperatureAlarm OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An indication of whether this temperature sensor is
|
||||
currently in an alarm condition. A value of TRUE indicates
|
||||
that its current reading is outside its threshold range,
|
||||
FALSE indicates that the current reading is acceptable."
|
||||
::= { envMonTemperatureEntry 6 }
|
||||
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- The Environment Monitoring Power Supply Bay Device Table
|
||||
-- ---------------------------------------------------------- --
|
||||
|
||||
envMonPsbObjects OBJECT IDENTIFIER ::= { envMon 4 }
|
||||
|
||||
envMonPsbTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EnvMonPsbEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table showing power supply bays in the system and info
|
||||
on any devices that are present."
|
||||
::= { envMonPsbObjects 1 }
|
||||
|
||||
envMonPsbEntry OBJECT-TYPE
|
||||
SYNTAX EnvMonPsbEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description and current status of a power supply
|
||||
bay device."
|
||||
INDEX { envMonPsbHostBoardIndex, envMonPsbHostSlotIndex }
|
||||
::= { envMonPsbTable 1 }
|
||||
|
||||
EnvMonPsbEntry ::=
|
||||
SEQUENCE {
|
||||
envMonPsbHostBoardIndex
|
||||
Unsigned32,
|
||||
envMonPsbHostSlotIndex
|
||||
Unsigned32,
|
||||
envMonPsbHeldBoardIndex
|
||||
Unsigned32,
|
||||
envMonPsbHeldBoardId
|
||||
OBJECT IDENTIFIER,
|
||||
envMonPsbDescription
|
||||
DisplayStringUnsized
|
||||
}
|
||||
|
||||
envMonPsbHostBoardIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the board hosting this PSB in the board table."
|
||||
::= { envMonPsbEntry 1 }
|
||||
|
||||
envMonPsbHostSlotIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of this PSB slot within the context of its host board.
|
||||
This index is fixed for each slot, on each type of board."
|
||||
::= { envMonPsbEntry 2 }
|
||||
|
||||
envMonPsbHeldBoardIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of a board installed in this power supply bay.
|
||||
This value corresponds to envMonPsbSensorBoardIndex for
|
||||
each sensor on this board. A value of 0 indicates that a
|
||||
board is is either not present or not supported."
|
||||
::= { envMonPsbEntry 3 }
|
||||
|
||||
envMonPsbHeldBoardId OBJECT-TYPE
|
||||
SYNTAX OBJECT IDENTIFIER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of board installed in this power supply bay. The
|
||||
values of this object are taken from the pprXxx object IDs
|
||||
under the boards sub-tree in the parent MIB. A value of 0
|
||||
indicates that a board is is either not present or not
|
||||
supported."
|
||||
::= { envMonPsbEntry 4 }
|
||||
|
||||
envMonPsbDescription OBJECT-TYPE
|
||||
SYNTAX DisplayStringUnsized (SIZE (0..30))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The text description of this power supply bay."
|
||||
::= { envMonPsbEntry 5 }
|
||||
|
||||
envMonPsbSensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EnvMonPsbSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of environment monitoring sensors on installed
|
||||
power supply bay devices."
|
||||
::= { envMonPsbObjects 2 }
|
||||
|
||||
envMonPsbSensorEntry OBJECT-TYPE
|
||||
SYNTAX EnvMonPsbSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description and current status of a power supply
|
||||
bay device."
|
||||
INDEX { envMonPsbSensorBoardIndex, envMonPsbSensorIndex }
|
||||
::= { envMonPsbSensorTable 1 }
|
||||
|
||||
EnvMonPsbSensorEntry ::=
|
||||
SEQUENCE {
|
||||
envMonPsbSensorBoardIndex
|
||||
Unsigned32,
|
||||
envMonPsbSensorIndex
|
||||
Unsigned32,
|
||||
envMonPsbSensorType
|
||||
EnvMonPsbSensorType,
|
||||
envMonPsbSensorDescription
|
||||
DisplayStringUnsized,
|
||||
envMonPsbSensorAlarm
|
||||
TruthValue
|
||||
}
|
||||
|
||||
envMonPsbSensorBoardIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the board hosting this sensor in the board table."
|
||||
::= { envMonPsbSensorEntry 1 }
|
||||
|
||||
envMonPsbSensorIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of this power supply bay environmental sensor, within the
|
||||
context of its host board."
|
||||
::= { envMonPsbSensorEntry 2 }
|
||||
|
||||
envMonPsbSensorType OBJECT-TYPE
|
||||
SYNTAX EnvMonPsbSensorType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the type of environmental variable this sensor detects."
|
||||
::= { envMonPsbSensorEntry 3 }
|
||||
|
||||
envMonPsbSensorDescription OBJECT-TYPE
|
||||
SYNTAX DisplayStringUnsized (SIZE (0..30))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The text description of this power supply bay environmental sensor."
|
||||
::= { envMonPsbSensorEntry 4 }
|
||||
|
||||
envMonPsbSensorAlarm OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An indication of whether this environmental sensor is currently
|
||||
in an alarm condition. A value of TRUE indicates that
|
||||
the device is in a failure condition, FALSE indicates
|
||||
that the device is functioning normally."
|
||||
::= { envMonPsbSensorEntry 5 }
|
||||
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- The Environment Monitoring SNMP Trap Objects
|
||||
-- ---------------------------------------------------------- --
|
||||
|
||||
envMonTraps OBJECT IDENTIFIER ::= { envMon 5 }
|
||||
|
||||
envMonFanAlarmSetEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonFanBoardIndex,
|
||||
envMonFanIndex,
|
||||
envMonFanDescription,
|
||||
envMonFanLowerThreshold,
|
||||
envMonFanCurrentSpeed }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when the monitored speed of a fan
|
||||
drops below its lower threshold."
|
||||
::= { envMonTraps 1 }
|
||||
|
||||
envMonFanAlarmClearedEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonFanBoardIndex,
|
||||
envMonFanIndex,
|
||||
envMonFanDescription,
|
||||
envMonFanLowerThreshold,
|
||||
envMonFanCurrentSpeed }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when the monitored speed of a fan
|
||||
returns to an acceptable value, the fan
|
||||
having previously been in an alarm condition."
|
||||
::= { envMonTraps 2 }
|
||||
|
||||
envMonVoltAlarmSetEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonVoltageBoardIndex,
|
||||
envMonVoltageIndex,
|
||||
envMonVoltageDescription,
|
||||
envMonVoltageUpperThreshold,
|
||||
envMonVoltageLowerThreshold,
|
||||
envMonVoltageCurrent }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when the voltage of a monitored
|
||||
voltage rail, goes out of tolerance by
|
||||
either dropping below its lower threshold,
|
||||
or exceeding its upper threshold."
|
||||
::= { envMonTraps 3 }
|
||||
|
||||
envMonVoltAlarmClearedEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonVoltageBoardIndex,
|
||||
envMonVoltageIndex,
|
||||
envMonVoltageDescription,
|
||||
envMonVoltageUpperThreshold,
|
||||
envMonVoltageLowerThreshold,
|
||||
envMonVoltageCurrent }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when the voltage of a monitored
|
||||
voltage rail returns to an acceptable value,
|
||||
having previously been in an alarm condition."
|
||||
::= { envMonTraps 4 }
|
||||
|
||||
envMonTempAlarmSetEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonTemperatureBoardIndex,
|
||||
envMonTemperatureIndex,
|
||||
envMonTemperatureDescription,
|
||||
envMonTemperatureUpperThreshold,
|
||||
envMonTemperatureCurrent }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when a monitored temperature
|
||||
exceeds its upper threshold."
|
||||
::= { envMonTraps 5 }
|
||||
|
||||
envMonTempAlarmClearedEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonTemperatureBoardIndex,
|
||||
envMonTemperatureIndex,
|
||||
envMonTemperatureDescription,
|
||||
envMonTemperatureUpperThreshold,
|
||||
envMonTemperatureCurrent }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when a monitored temperature
|
||||
returns to an acceptable value, having
|
||||
previously been in an alarm condition."
|
||||
::= { envMonTraps 6 }
|
||||
|
||||
envMonPsbAlarmSetEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonPsbSensorBoardIndex,
|
||||
envMonPsbSensorIndex,
|
||||
envMonPsbSensorType,
|
||||
envMonPsbSensorDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when a monitored parameter of
|
||||
a power supply bay device goes out of
|
||||
tolerance."
|
||||
::= { envMonTraps 7 }
|
||||
|
||||
envMonPsbAlarmClearedEvent NOTIFICATION-TYPE
|
||||
OBJECTS { envMonPsbSensorBoardIndex,
|
||||
envMonPsbSensorIndex,
|
||||
envMonPsbSensorType,
|
||||
envMonPsbSensorDescription }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Triggered when a monitored parameter of
|
||||
a power supply bay device returns to an
|
||||
acceptable value, having previously been
|
||||
in an alarm condition."
|
||||
::= { envMonTraps 8 }
|
||||
|
||||
END
|