Initial commit
This commit is contained in:
182
MIBS/arris/DOCS-TEST-MIB
Normal file
182
MIBS/arris/DOCS-TEST-MIB
Normal file
@ -0,0 +1,182 @@
|
||||
DOCS-TEST-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
-- do not import BITS,
|
||||
Integer32,
|
||||
enterprises
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION,
|
||||
TruthValue
|
||||
FROM SNMPv2-TC
|
||||
OBJECT-GROUP,
|
||||
MODULE-COMPLIANCE
|
||||
FROM SNMPv2-CONF;
|
||||
|
||||
|
||||
-- These are the defined Cablelabs OID paths. Not all are needed for the Test MIB,
|
||||
-- but included here for sake of completeness.
|
||||
cableLabs OBJECT IDENTIFIER ::= { enterprises 4491 }
|
||||
clabFunction OBJECT IDENTIFIER ::= { cableLabs 1 }
|
||||
clabFuncMib2 OBJECT IDENTIFIER ::= { clabFunction 1 }
|
||||
clabFuncProprietary OBJECT IDENTIFIER ::= { clabFunction 2 }
|
||||
clabProject OBJECT IDENTIFIER ::= { cableLabs 2 }
|
||||
clabProjDocsis OBJECT IDENTIFIER ::= { clabProject 1 }
|
||||
clabProjPacketCable OBJECT IDENTIFIER ::= { clabProject 2 }
|
||||
clabProjOpenCable OBJECT IDENTIFIER ::= { clabProject 3 }
|
||||
clabProjCableHome OBJECT IDENTIFIER ::= { clabProject 4 }
|
||||
|
||||
|
||||
docsTestMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "0203150000Z" -- March 15, 2002
|
||||
ORGANIZATION "DOCSIS 2.0 ATP Working Group"
|
||||
CONTACT-INFO
|
||||
" David Raftus
|
||||
Postal: Imedia Semiconductor
|
||||
340 Terry Fox Drive, Suite 202
|
||||
Ottawa Ontario
|
||||
Canada
|
||||
Phone: +1 613 592 1052
|
||||
E-mail: david.raftus@imedia.com
|
||||
|
||||
DOCSIS 2.0 ATP Working Group
|
||||
General Discussion: docsis-20@cablelabs.com,
|
||||
docsis-20-atp@cablelabs.com"
|
||||
DESCRIPTION
|
||||
"This is the MIB Module supporting programmable test features
|
||||
for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem
|
||||
Termination Systems (CMTS)."
|
||||
-- 4491 is the IANA Cablelabs enterprise number
|
||||
::= { clabProjDocsis 12 }
|
||||
|
||||
|
||||
|
||||
-- Textual Conventions
|
||||
-- none required yet - dave - leave as a placeholder
|
||||
|
||||
|
||||
-- Mapping path to the test mib.
|
||||
--
|
||||
docsTestMibObjects OBJECT IDENTIFIER ::= { docsTestMIB 1 }
|
||||
docsTestBaseObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 1 }
|
||||
docsTestSetupObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 2 }
|
||||
|
||||
--
|
||||
-- docsTestBaseObjects
|
||||
--
|
||||
-- These objects indicate the capability and current status of the
|
||||
-- programmable test features on the CM/CMTS.
|
||||
--
|
||||
|
||||
docsTestCapability OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the ability of this device to support the
|
||||
programmable features identified by the TYPE field from
|
||||
the CM/CMTS TLV table in [17] and section 3.1.2.
|
||||
Each octet within this octet string represents eight tests.
|
||||
For example, the first octet represents tests one through eight
|
||||
as identified by the TYPE field."
|
||||
::= { docsTestBaseObjects 1 }
|
||||
|
||||
docsTestStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the current operating status of tests initiated
|
||||
through the docsTestSetupObjects. The octet representation is
|
||||
identical to that used by docsTestCapability. A bit representation
|
||||
of one indicates that a test is currently active, while zero
|
||||
indicates the test is inactive or has completed."
|
||||
::= { docsTestBaseObjects 2 }
|
||||
|
||||
|
||||
--
|
||||
-- docsTestSetupObjects
|
||||
--
|
||||
-- These objects setup the test parameters ands initiate the test.
|
||||
--
|
||||
|
||||
docsTestType OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..1023)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Corresponds to the TYPE field from the CM/CMTS TLV Table
|
||||
in [17] and section 3.1.2. The default value of zero indicates
|
||||
no test has yet been initiated.
|
||||
A WrongValueError should be returned in response to a write
|
||||
request for a test not supported by the device. A read request
|
||||
will return the docsTestType value last successfully written,
|
||||
whether that test is active or inactive."
|
||||
DEFVAL { 0 }
|
||||
::= { docsTestSetupObjects 1 }
|
||||
|
||||
docsTestData OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Corresponds to the LENGTH and VALUE fields from the CM/CMTS TLV
|
||||
Table in [17] and section 3.1.2. A read request will return the
|
||||
docsTestData value last successfully written, whether that test
|
||||
is active or inactive."
|
||||
::= { docsTestSetupObjects 2 }
|
||||
|
||||
docsTestEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Used to initiate or stop the tests setup through the docsTestType
|
||||
and docsTestData objects.
|
||||
A CommitFailedError should be returned in response to a TRUE
|
||||
Write request if the values in docsTestType and docsTestData are
|
||||
incompatible, or a test could not be initiated for any other
|
||||
reason."
|
||||
::= { docsTestSetupObjects 3 }
|
||||
|
||||
|
||||
|
||||
|
||||
-- Compliance statements
|
||||
|
||||
docsTestConformance OBJECT IDENTIFIER ::= { docsTestMIB 2 }
|
||||
docsTestCompliances OBJECT IDENTIFIER ::= { docsTestConformance 1 }
|
||||
docsTestGroups OBJECT IDENTIFIER ::= { docsTestConformance 2 }
|
||||
|
||||
|
||||
docsTestBasicCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for devices that implement
|
||||
the DOCSIS compliant programmable test features."
|
||||
|
||||
MODULE -- docsTestMib
|
||||
|
||||
-- unconditionally mandatory groups
|
||||
MANDATORY-GROUPS {
|
||||
docsTestGroup
|
||||
} ::= { docsTestCompliances 1 }
|
||||
|
||||
|
||||
docsTestGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
docsTestCapability,
|
||||
docsTestStatus,
|
||||
docsTestType,
|
||||
docsTestData,
|
||||
docsTestEnable
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Group of objects implemented in both Cable Modems and
|
||||
Cable Modem Termination Systems."
|
||||
::= { docsTestGroups 1 }
|
||||
|
||||
|
||||
END
|