Initial commit
This commit is contained in:
943
MIBS/cisco/CISCO-ENTITY-SENSOR-MIB
Normal file
943
MIBS/cisco/CISCO-ENTITY-SENSOR-MIB
Normal file
@ -0,0 +1,943 @@
|
||||
-- *****************************************************************
|
||||
-- CISCO-ENTITY-SENSOR-MIB
|
||||
--
|
||||
-- November 1997, Cliff L. Sojourner
|
||||
--
|
||||
-- Copyright (c) 1998-2003-2006, 2013, 2015 by cisco Systems Inc.
|
||||
-- All rights reserved.
|
||||
-- *****************************************************************
|
||||
|
||||
CISCO-ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP,
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TEXTUAL-CONVENTION,
|
||||
TimeStamp,
|
||||
TruthValue
|
||||
FROM SNMPv2-TC
|
||||
entPhysicalIndex
|
||||
FROM ENTITY-MIB
|
||||
EntPhysicalIndexOrZero
|
||||
FROM CISCO-TC
|
||||
ciscoMgmt
|
||||
FROM CISCO-SMI;
|
||||
|
||||
|
||||
ciscoEntitySensorMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201501150000Z"
|
||||
ORGANIZATION "Cisco Systems, Inc."
|
||||
CONTACT-INFO
|
||||
"Postal: Cisco Systems, Inc.
|
||||
170 West Tasman Drive
|
||||
San Jose, CA 95134-1706
|
||||
USA
|
||||
|
||||
Tel: +1 408 526 4000
|
||||
|
||||
E-mail: cs-snmp@cisco.com"
|
||||
DESCRIPTION
|
||||
"The CISCO-ENTITY-SENSOR-MIB is used to monitor
|
||||
the values of sensors in the Entity-MIB (RFC 2037)
|
||||
entPhysicalTable."
|
||||
REVISION "201501150000Z"
|
||||
DESCRIPTION
|
||||
"Corrected the definition of entSensorPrecision."
|
||||
REVISION "201309210000Z"
|
||||
DESCRIPTION
|
||||
"Added entSensorThresholdRecoveryNotification to
|
||||
entitySensorMIBNotifications.
|
||||
Added entSensorThresholdSeverity as a varbind
|
||||
object to entSensorThresholdNotification.
|
||||
Added entitySensorNotificationGroup
|
||||
and deprecated
|
||||
entitySensorThresholdNotificationGroup.
|
||||
Added entSensorThresholdNotification and
|
||||
entSensorThresholdRecoveryNotification to
|
||||
entitySensorNotificationGroup.
|
||||
Added entitySensorMIBComplianceV05 and
|
||||
deprecated entitySensorMIBComplianceV04."
|
||||
REVISION "200711120000Z"
|
||||
DESCRIPTION
|
||||
"Added entitySensorNotifCtrlGlobalGroup."
|
||||
REVISION "200601010000Z"
|
||||
DESCRIPTION
|
||||
"Add new object entSensorMeasuredEntity to
|
||||
entSensorValueTable."
|
||||
REVISION "200509080000Z"
|
||||
DESCRIPTION
|
||||
"Change the module descriptor name from entitySensorMIB
|
||||
to ciscoEntitySensorMIB since ENTITY-SENSOR-MIB also
|
||||
uses the same name and there is a conflict."
|
||||
REVISION "200301070000Z"
|
||||
DESCRIPTION
|
||||
"[1] Add dBm(14) in SensorDataType."
|
||||
REVISION "200210160000Z"
|
||||
DESCRIPTION
|
||||
"[1] Add critical(30) in CSensorThresholdSeverity.
|
||||
[2] Change to MAX-ACCESS read-write for 3 objects.
|
||||
[3] Add entitySensorMIBComplianceV02."
|
||||
REVISION "200006200000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
::= { ciscoMgmt 91 }
|
||||
|
||||
|
||||
entitySensorMIBObjects OBJECT IDENTIFIER
|
||||
::= { ciscoEntitySensorMIB 1 }
|
||||
|
||||
entitySensorMIBNotificationPrefix OBJECT IDENTIFIER
|
||||
::= { ciscoEntitySensorMIB 2 }
|
||||
|
||||
entitySensorMIBConformance OBJECT IDENTIFIER
|
||||
::= { ciscoEntitySensorMIB 3 }
|
||||
|
||||
|
||||
-- textual conventions
|
||||
|
||||
SensorDataType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"sensor measurement data types. valid values are:
|
||||
other(1): a measure other than those listed below
|
||||
unknown(2): unknown measurement, or
|
||||
arbitrary, relative numbers
|
||||
voltsAC(3): electric potential
|
||||
voltsDC(4): electric potential
|
||||
amperes(5): electric current
|
||||
watts(6): power
|
||||
hertz(7): frequency
|
||||
celsius(8): temperature
|
||||
percentRH(9): percent relative humidity
|
||||
rpm(10): shaft revolutions per minute
|
||||
cmm(11),: cubic meters per minute (airflow)
|
||||
truthvalue(12): value takes { true(1), false(2) }
|
||||
specialEnum(13): value takes user defined enumerated values
|
||||
dBm(14): dB relative to 1mW of power"
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
unknown(2),
|
||||
voltsAC(3),
|
||||
voltsDC(4),
|
||||
amperes(5),
|
||||
watts(6),
|
||||
hertz(7),
|
||||
celsius(8),
|
||||
percentRH(9),
|
||||
rpm(10),
|
||||
cmm(11),
|
||||
truthvalue(12),
|
||||
specialEnum(13),
|
||||
dBm(14)
|
||||
}
|
||||
|
||||
SensorDataScale ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"International System of Units (SI) prefixes."
|
||||
SYNTAX INTEGER {
|
||||
yocto(1), -- 10^-24
|
||||
zepto(2), -- 10^-21
|
||||
atto(3), -- 10^-18
|
||||
femto(4), -- 10^-15
|
||||
pico(5), -- 10^-12
|
||||
nano(6), -- 10^-9
|
||||
micro(7), -- 10^-6
|
||||
milli(8), -- 10^-3
|
||||
units(9), -- 10^0
|
||||
kilo(10), -- 10^3
|
||||
mega(11), -- 10^6
|
||||
giga(12), -- 10^9
|
||||
tera(13), -- 10^12
|
||||
exa(14), -- 10^15
|
||||
peta(15), -- 10^18
|
||||
zetta(16), -- 10^21
|
||||
yotta(17) -- 10^24
|
||||
}
|
||||
|
||||
SensorPrecision ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When in the range 1 to 9, SensorPrecision is the number
|
||||
of decimal places in the fractional part of
|
||||
a SensorValue fixed-point number. When in the range -8 to
|
||||
-1, SensorPrecision is the number of accurate digits in
|
||||
a SensorValue fixed-point number.
|
||||
|
||||
SensorPrecision is 0 for non-fixed-point numbers.
|
||||
|
||||
Agent implementors must choose a value for SensorPrecision
|
||||
so that the precision and accuracy of a SensorValue is
|
||||
correctly indicated.
|
||||
|
||||
For example, a temperature sensor that can measure 0o to
|
||||
100o C in 0.1o increments, +/- 0.05o, would have a
|
||||
SensorPrecision of 1, a SensorDataScale of units(0), and a
|
||||
SensorValue ranging from 0 to 1000.
|
||||
The SensorValue would be interpreted as (degrees C * 10).
|
||||
|
||||
If that temperature sensor's precision were 0.1o but its
|
||||
accuracy were only +/- 0.5o, then the SensorPrecision would
|
||||
be 0. The SensorValue would be interpreted as degrees C.
|
||||
|
||||
Another example: a fan rotation speed sensor that measures RPM
|
||||
from 0 to 10,000 in 100 RPM increments, with an accuracy of
|
||||
+50/-37 RPM, would have a SensorPrecision of -2, a
|
||||
SensorDataScale of units(9), and a SensorValue ranging from 0
|
||||
to 10000. The 10s and 1s digits of SensorValue would always
|
||||
be 0."
|
||||
SYNTAX INTEGER (-8..9)
|
||||
|
||||
SensorValue ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"For sensors that measure voltsAC, voltsDC,
|
||||
amperes, watts, hertz, celsius, cmm
|
||||
this item is a fixed point number ranging from
|
||||
-999,999,999 to +999,999,999. Use the value
|
||||
-1000000000 to indicate underflow. Use the value
|
||||
+1000000000 to indicate overflow. Use SensorPrecision
|
||||
to indicate how many fractional digits the SensorValue
|
||||
has.
|
||||
|
||||
|
||||
For sensors that measure percentRH, this item
|
||||
is a number ranging from 0 to 100.
|
||||
|
||||
For sensors that measure rpm, this item
|
||||
can take only nonnegative values, 0..999999999.
|
||||
|
||||
For sensors of type truthvalue, this item
|
||||
can take only two values: true(1), false(2).
|
||||
|
||||
For sensors of type specialEnum, this item
|
||||
can take any value in the range (-1000000000..1000000000),
|
||||
but the meaning of each value is specific to the
|
||||
sensor.
|
||||
|
||||
For sensors of type other and unknown,
|
||||
this item can take any value in the range
|
||||
(-1000000000..1000000000), but the meaning of the values
|
||||
are specific to the sensor.
|
||||
|
||||
Use Entity-MIB entPhysicalTable.entPhysicalVendorType
|
||||
to learn about the sensor type."
|
||||
SYNTAX INTEGER (-1000000000..1000000000)
|
||||
|
||||
SensorStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the operational status of the sensor.
|
||||
|
||||
ok(1) means the agent can read the sensor
|
||||
value.
|
||||
|
||||
unavailable(2) means that the agent presently
|
||||
can not report the sensor value.
|
||||
|
||||
nonoperational(3) means that the agent believes
|
||||
the sensor is broken. The sensor could have a
|
||||
hard failure (disconnected wire), or a soft failure
|
||||
such as out-of-range, jittery, or wildly fluctuating
|
||||
readings."
|
||||
SYNTAX INTEGER {
|
||||
ok(1),
|
||||
unavailable(2),
|
||||
nonoperational(3)
|
||||
}
|
||||
|
||||
SensorValueUpdateRate ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the interval in seconds between updates to the
|
||||
sensor's value.
|
||||
|
||||
The value zero indicates:
|
||||
- the sensor value is updated on demand (when polled by the
|
||||
agent for a get-request),
|
||||
- or when the sensor value changes (event-driven),
|
||||
- or the agent does not know the rate"
|
||||
SYNTAX INTEGER (0..999999999)
|
||||
|
||||
SensorThresholdSeverity ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"sensor threshold severity. Valid values are:
|
||||
|
||||
other(1) : a severity other than those listed below.
|
||||
minor(10) : Minor Problem threshold.
|
||||
major(20) : Major Problem threshold.
|
||||
critical(30): Critical problem threshold. A system might shut
|
||||
down the sensor associated FRU automatically if
|
||||
the sensor value reach the critical problem
|
||||
threshold."
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
minor(10),
|
||||
major(20),
|
||||
critical(30)
|
||||
}
|
||||
|
||||
SensorThresholdRelation ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"sensor threshold relational operator types. valid values are:
|
||||
|
||||
lessThan(1): if the sensor value is less than
|
||||
the threshold value
|
||||
lessOrEqual(2): if the sensor value is less than or equal to
|
||||
the threshold value
|
||||
greaterThan(3): if the sensor value is greater than
|
||||
the threshold value
|
||||
greaterOrEqual(4): if the sensor value is greater than or equal
|
||||
to the threshold value
|
||||
equalTo(5): if the sensor value is equal to
|
||||
the threshold value
|
||||
notEqualTo(6): if the sensor value is not equal to
|
||||
the threshold value"
|
||||
SYNTAX INTEGER {
|
||||
lessThan(1),
|
||||
lessOrEqual(2),
|
||||
greaterThan(3),
|
||||
greaterOrEqual(4),
|
||||
equalTo(5),
|
||||
notEqualTo(6)
|
||||
}
|
||||
-- MIB variables
|
||||
|
||||
entSensorValues OBJECT IDENTIFIER
|
||||
::= { entitySensorMIBObjects 1 }
|
||||
|
||||
entSensorThresholds OBJECT IDENTIFIER
|
||||
::= { entitySensorMIBObjects 2 }
|
||||
|
||||
entSensorGlobalObjects OBJECT IDENTIFIER
|
||||
::= { entitySensorMIBObjects 3 }
|
||||
|
||||
-- entSensorValueTable
|
||||
|
||||
entSensorValueTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EntSensorValueEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table lists the type, scale, and present value
|
||||
of a sensor listed in the Entity-MIB entPhysicalTable."
|
||||
::= { entSensorValues 1 }
|
||||
|
||||
entSensorValueEntry OBJECT-TYPE
|
||||
SYNTAX EntSensorValueEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entSensorValueTable entry describes the
|
||||
present reading of a sensor, the measurement units
|
||||
and scale, and sensor operational status."
|
||||
INDEX { entPhysicalIndex }
|
||||
::= { entSensorValueTable 1 }
|
||||
|
||||
EntSensorValueEntry ::= SEQUENCE {
|
||||
entSensorType SensorDataType,
|
||||
entSensorScale SensorDataScale,
|
||||
entSensorPrecision SensorPrecision,
|
||||
entSensorValue SensorValue,
|
||||
entSensorStatus SensorStatus,
|
||||
entSensorValueTimeStamp TimeStamp,
|
||||
entSensorValueUpdateRate SensorValueUpdateRate,
|
||||
entSensorMeasuredEntity EntPhysicalIndexOrZero
|
||||
}
|
||||
|
||||
entSensorType OBJECT-TYPE
|
||||
SYNTAX SensorDataType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the type of data
|
||||
reported by the entSensorValue.
|
||||
|
||||
This variable is set by the agent at start-up
|
||||
and the value does not change during operation."
|
||||
::= { entSensorValueEntry 1 }
|
||||
|
||||
entSensorScale OBJECT-TYPE
|
||||
SYNTAX SensorDataScale
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the exponent to apply
|
||||
to sensor values reported by entSensorValue.
|
||||
|
||||
This variable is set by the agent at start-up
|
||||
and the value does not change during operation."
|
||||
::= { entSensorValueEntry 2 }
|
||||
|
||||
entSensorPrecision OBJECT-TYPE
|
||||
SYNTAX SensorPrecision
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the number of decimal
|
||||
places of precision in fixed-point
|
||||
sensor values reported by entSensorValue.
|
||||
|
||||
This variable is set to 0 when entSensorType
|
||||
is not a fixed-point type: e.g.'percentRH(9)',
|
||||
'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
|
||||
|
||||
This variable is set by the agent at start-up
|
||||
and the value does not change during operation."
|
||||
::= { entSensorValueEntry 3 }
|
||||
|
||||
entSensorValue OBJECT-TYPE
|
||||
SYNTAX SensorValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable reports the most recent measurement seen
|
||||
by the sensor.
|
||||
|
||||
To correctly display or interpret this variable's value,
|
||||
you must also know entSensorType, entSensorScale, and
|
||||
entSensorPrecision.
|
||||
|
||||
However, you can compare entSensorValue with the threshold
|
||||
values given in entSensorThresholdTable without any semantic
|
||||
knowledge."
|
||||
::= { entSensorValueEntry 4 }
|
||||
|
||||
entSensorStatus OBJECT-TYPE
|
||||
SYNTAX SensorStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the present operational status
|
||||
of the sensor."
|
||||
::= { entSensorValueEntry 5 }
|
||||
|
||||
entSensorValueTimeStamp OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the age of the value reported by
|
||||
entSensorValue"
|
||||
::= { entSensorValueEntry 6 }
|
||||
|
||||
entSensorValueUpdateRate OBJECT-TYPE
|
||||
SYNTAX SensorValueUpdateRate
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the rate that the agent
|
||||
updates entSensorValue."
|
||||
::= { entSensorValueEntry 7 }
|
||||
|
||||
entSensorMeasuredEntity OBJECT-TYPE
|
||||
SYNTAX EntPhysicalIndexOrZero
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object identifies the physical entity for which the
|
||||
sensor is taking measurements. For example, for a sensor
|
||||
measuring the voltage output of a power-supply, this object
|
||||
would be the entPhysicalIndex of that power-supply; for a sensor
|
||||
measuring the temperature inside one chassis of a multi-chassis
|
||||
system, this object would be the enPhysicalIndex of that
|
||||
chassis.
|
||||
|
||||
This object has a value of zero when the physical entity
|
||||
for which the sensor is taking measurements can not be
|
||||
represented by any one row in the entPhysicalTable, or that
|
||||
there is no such physical entity."
|
||||
::= { entSensorValueEntry 8 }
|
||||
|
||||
|
||||
-- entSensorThresholdTable
|
||||
|
||||
entSensorThresholdTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EntSensorThresholdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table lists the threshold severity, relation, and
|
||||
comparison value, for a sensor listed in the Entity-MIB
|
||||
entPhysicalTable."
|
||||
::= { entSensorThresholds 1 }
|
||||
|
||||
entSensorThresholdEntry OBJECT-TYPE
|
||||
SYNTAX EntSensorThresholdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entSensorThresholdTable entry describes the
|
||||
thresholds for a sensor: the threshold severity,
|
||||
the threshold value, the relation, and the
|
||||
evaluation of the threshold.
|
||||
|
||||
Only entities of type sensor(8) are listed in this table.
|
||||
Only pre-configured thresholds are listed in this table.
|
||||
|
||||
Users can create sensor-value monitoring instruments
|
||||
in different ways, such as RMON alarms, Expression-MIB, etc.
|
||||
|
||||
Entries are created by the agent at system startup and
|
||||
FRU insertion. Entries are deleted by the agent at
|
||||
FRU removal."
|
||||
INDEX {
|
||||
entPhysicalIndex,
|
||||
entSensorThresholdIndex
|
||||
}
|
||||
::= { entSensorThresholdTable 1 }
|
||||
|
||||
EntSensorThresholdEntry ::= SEQUENCE {
|
||||
entSensorThresholdIndex Integer32,
|
||||
entSensorThresholdSeverity SensorThresholdSeverity,
|
||||
entSensorThresholdRelation SensorThresholdRelation,
|
||||
entSensorThresholdValue SensorValue,
|
||||
entSensorThresholdEvaluation TruthValue,
|
||||
entSensorThresholdNotificationEnable TruthValue
|
||||
}
|
||||
|
||||
entSensorThresholdIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..99999999)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An index that uniquely identifies an entry
|
||||
in the entSensorThresholdTable. This index
|
||||
permits the same sensor to have several
|
||||
different thresholds."
|
||||
::= { entSensorThresholdEntry 1 }
|
||||
|
||||
entSensorThresholdSeverity OBJECT-TYPE
|
||||
SYNTAX SensorThresholdSeverity
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the severity of this threshold."
|
||||
::= { entSensorThresholdEntry 2 }
|
||||
|
||||
entSensorThresholdRelation OBJECT-TYPE
|
||||
SYNTAX SensorThresholdRelation
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the relation between sensor value
|
||||
(entSensorValue) and threshold value (entSensorThresholdValue),
|
||||
required to trigger the alarm. when evaluating the relation,
|
||||
entSensorValue is on the left of entSensorThresholdRelation,
|
||||
entSensorThresholdValue is on the right.
|
||||
|
||||
in pseudo-code, the evaluation-alarm mechanism is:
|
||||
|
||||
...
|
||||
if (entSensorStatus == ok) then
|
||||
if (evaluate(entSensorValue, entSensorThresholdRelation,
|
||||
entSensorThresholdValue))
|
||||
then
|
||||
if (entSensorThresholdNotificationEnable == true))
|
||||
then
|
||||
raise_alarm(sensor's entPhysicalIndex);
|
||||
endif
|
||||
endif
|
||||
endif
|
||||
..."
|
||||
::= { entSensorThresholdEntry 3 }
|
||||
|
||||
entSensorThresholdValue OBJECT-TYPE
|
||||
SYNTAX SensorValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the value of the threshold.
|
||||
|
||||
To correctly display or interpret this variable's value,
|
||||
you must also know entSensorType, entSensorScale, and
|
||||
entSensorPrecision.
|
||||
|
||||
However, you can directly compare entSensorValue
|
||||
with the threshold values given in entSensorThresholdTable
|
||||
without any semantic knowledge."
|
||||
::= { entSensorThresholdEntry 4 }
|
||||
|
||||
entSensorThresholdEvaluation OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the result of the most
|
||||
recent evaluation of the threshold. If the threshold
|
||||
condition is true, entSensorThresholdEvaluation
|
||||
is true(1). If the threshold condition is false,
|
||||
entSensorThresholdEvaluation is false(2).
|
||||
|
||||
Thresholds are evaluated at the rate indicated by
|
||||
entSensorValueUpdateRate."
|
||||
::= { entSensorThresholdEntry 5 }
|
||||
|
||||
entSensorThresholdNotificationEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable controls generation of
|
||||
entSensorThresholdNotification for this threshold.
|
||||
|
||||
When this variable is 'true', generation of
|
||||
entSensorThresholdNotification is enabled for this
|
||||
threshold. When this variable is 'false',
|
||||
generation of entSensorThresholdNotification is
|
||||
disabled for this threshold."
|
||||
::= { entSensorThresholdEntry 6 }
|
||||
|
||||
|
||||
|
||||
-- Entity Sensor Global Objects
|
||||
|
||||
entSensorThreshNotifGlobalEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable enables the generation of
|
||||
entSensorThresholdNotification globally
|
||||
on the device. If this object value is
|
||||
'false', then no entSensorThresholdNotification
|
||||
will be generated on this device. If this object
|
||||
value is 'true', then whether a
|
||||
entSensorThresholdNotification for a threshold will
|
||||
be generated or not depends on the instance value of
|
||||
entSensorThresholdNotificationEnable for that
|
||||
threshold."
|
||||
::= { entSensorGlobalObjects 1 }
|
||||
-- notifications
|
||||
|
||||
entitySensorMIBNotifications OBJECT IDENTIFIER
|
||||
::= { entitySensorMIBNotificationPrefix 0 }
|
||||
|
||||
|
||||
entSensorThresholdNotification NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
entSensorThresholdValue,
|
||||
entSensorValue,
|
||||
entSensorThresholdSeverity
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The notification is generated when
|
||||
the sensor value entSensorValue crosses
|
||||
the threshold value entSensorThresholdValue and
|
||||
the value of entSensorThreshNotifGlobalEnable is true.
|
||||
|
||||
entSensorThresholdSeverity indicates the severity
|
||||
of this threshold.
|
||||
|
||||
The agent implementation guarantees prompt, timely
|
||||
evaluation of threshold and generation of this
|
||||
notification."
|
||||
::= { entitySensorMIBNotifications 1 }
|
||||
|
||||
entSensorThresholdRecoveryNotification NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
entSensorValue,
|
||||
entSensorThresholdSeverity,
|
||||
entSensorThresholdValue
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is generated
|
||||
as a recovery notification when
|
||||
the sensor value entSensorValue goes below
|
||||
the threshold value entSensorThresholdValue
|
||||
once it has generated entSensorThresholdNotification.
|
||||
The value of entSensorThreshNotifGlobalEnable needs
|
||||
to be true.
|
||||
|
||||
entSensorThresholdSeverity indicates the severity
|
||||
of this threshold.
|
||||
|
||||
The agent implementation guarantees prompt, timely
|
||||
evaluation of threshold and generation of this
|
||||
notification."
|
||||
::= { entitySensorMIBNotifications 2 }
|
||||
-- conformance information
|
||||
|
||||
entitySensorMIBCompliances OBJECT IDENTIFIER
|
||||
::= { entitySensorMIBConformance 1 }
|
||||
|
||||
entitySensorMIBGroups OBJECT IDENTIFIER
|
||||
::= { entitySensorMIBConformance 2 }
|
||||
|
||||
|
||||
-- compliance statements
|
||||
|
||||
entitySensorMIBComplianceV01 MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"An Entity-MIB implementation that lists
|
||||
sensors in its entPhysicalTable must implement
|
||||
this group."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
entitySensorValueGroup,
|
||||
entitySensorThresholdGroup,
|
||||
entitySensorThresholdNotificationGroup
|
||||
}
|
||||
::= { entitySensorMIBCompliances 1 }
|
||||
|
||||
entitySensorMIBComplianceV02 MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"An Entity-MIB implementation that lists
|
||||
sensors in its entPhysicalTable must implement
|
||||
this group."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
||||
|
||||
GROUP entitySensorValueGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which don't
|
||||
support IETF version of ENTITY-SENSOR-MIB."
|
||||
|
||||
GROUP entitySensorThresholdNotificationGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which support
|
||||
entitySensorValueGroup group."
|
||||
|
||||
OBJECT entSensorThresholdSeverity
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdRelation
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdValue
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
::= { entitySensorMIBCompliances 2 }
|
||||
|
||||
entitySensorMIBComplianceV03 MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"An Entity-MIB implementation that lists
|
||||
sensors in its entPhysicalTable must implement
|
||||
this group."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
||||
|
||||
GROUP entitySensorValueGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which don't
|
||||
support IETF version of ENTITY-SENSOR-MIB."
|
||||
|
||||
GROUP entitySensorThresholdNotificationGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which support
|
||||
entitySensorValueGroup group."
|
||||
|
||||
GROUP entitySensorValueGroupSup1
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which support
|
||||
the correlation between sensor and its measured
|
||||
physical entity."
|
||||
|
||||
OBJECT entSensorThresholdSeverity
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdRelation
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdValue
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
::= { entitySensorMIBCompliances 3 }
|
||||
|
||||
entitySensorMIBComplianceV04 MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"An Entity-MIB implementation that lists
|
||||
sensors in its entPhysicalTable must implement
|
||||
this group."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
||||
|
||||
GROUP entitySensorValueGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which don't
|
||||
support IETF version of ENTITY-SENSOR-MIB."
|
||||
|
||||
GROUP entitySensorThresholdNotificationGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which support
|
||||
entitySensorValueGroup group."
|
||||
|
||||
GROUP entitySensorValueGroupSup1
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems which support
|
||||
the correlation between sensor and its measured
|
||||
physical entity."
|
||||
|
||||
GROUP entitySensorNotifCtrlGlobalGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the platforms which support
|
||||
global notification control on
|
||||
entSensorThresholdNotification."
|
||||
|
||||
OBJECT entSensorThresholdSeverity
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdRelation
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdValue
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
::= { entitySensorMIBCompliances 4 }
|
||||
|
||||
entitySensorMIBComplianceV05 MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An Entity-MIB implementation that lists
|
||||
sensors in its entPhysicalTable must implement
|
||||
this group."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { entitySensorThresholdGroup }
|
||||
|
||||
GROUP entitySensorValueGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems
|
||||
which don't support IETF version of
|
||||
ENTITY-SENSOR-MIB."
|
||||
|
||||
GROUP entitySensorValueGroupSup1
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems
|
||||
which don't support IETF version of
|
||||
ENTITY-SENSOR-MIB."
|
||||
|
||||
GROUP entitySensorNotifCtrlGlobalGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems
|
||||
which don't support IETF version of
|
||||
ENTITY-SENSOR-MIB."
|
||||
|
||||
GROUP entitySensorNotificationGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for the systems
|
||||
which don't support IETF version of
|
||||
ENTITY-SENSOR-MIB."
|
||||
|
||||
OBJECT entSensorThresholdSeverity
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdRelation
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT entSensorThresholdValue
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
::= { entitySensorMIBCompliances 5 }
|
||||
|
||||
-- units of conformance
|
||||
|
||||
entitySensorValueGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
entSensorType,
|
||||
entSensorScale,
|
||||
entSensorPrecision,
|
||||
entSensorValue,
|
||||
entSensorStatus,
|
||||
entSensorValueTimeStamp,
|
||||
entSensorValueUpdateRate
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects which are used
|
||||
to describe and monitor values of Entity-MIB
|
||||
entPhysicalTable entries of sensors."
|
||||
::= { entitySensorMIBGroups 1 }
|
||||
|
||||
entitySensorThresholdGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
entSensorThresholdSeverity,
|
||||
entSensorThresholdRelation,
|
||||
entSensorThresholdValue,
|
||||
entSensorThresholdEvaluation,
|
||||
entSensorThresholdNotificationEnable
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects which are used
|
||||
to describe and monitor thresholds for
|
||||
sensors."
|
||||
::= { entitySensorMIBGroups 2 }
|
||||
|
||||
entitySensorThresholdNotificationGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { entSensorThresholdNotification }
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The collection of notifications used for
|
||||
monitoring sensor threshold activity.
|
||||
entitySensorThresholdNotificationGroup
|
||||
object is superseded by
|
||||
entitySensorNotificationGroup."
|
||||
::= { entitySensorMIBGroups 3 }
|
||||
|
||||
entitySensorValueGroupSup1 OBJECT-GROUP
|
||||
OBJECTS { entSensorMeasuredEntity }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects which are used to describe and track
|
||||
the measured entities of ENTITY-MIB entPhysicalTable."
|
||||
::= { entitySensorMIBGroups 4 }
|
||||
|
||||
entitySensorNotifCtrlGlobalGroup OBJECT-GROUP
|
||||
OBJECTS { entSensorThreshNotifGlobalEnable }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects which provide the global
|
||||
notification control on entSensorThresholdNotification."
|
||||
::= { entitySensorMIBGroups 5 }
|
||||
|
||||
entitySensorNotificationGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
entSensorThresholdNotification,
|
||||
entSensorThresholdRecoveryNotification
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of notifications used for
|
||||
monitoring sensor threshold activity."
|
||||
::= { entitySensorMIBGroups 6 }
|
||||
|
||||
END
|
||||
|
||||
|
||||
|
Reference in New Issue