@ -0,0 +1,543 @@
|
||||
-- =================================================================
|
||||
-- Copyright (c) 2004-2011 New H3C Tech. Co., Ltd. All rights reserved.
|
||||
--
|
||||
-- Description: This MIB define objects for MPLS Te Tunnel.
|
||||
-- Reference:
|
||||
-- Version: V1.0
|
||||
-- History:
|
||||
-- V1.0 2011-03-24 Created by fengnina 04924.
|
||||
-- ==================================================================
|
||||
|
||||
HH3C-TE-TUNNEL-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
hh3cCommon
|
||||
FROM HH3C-OID-MIB
|
||||
MplsTunnelIndex, MplsTunnelInstanceIndex, MplsExtendedTunnelId, MplsLabel
|
||||
FROM MPLS-TC-STD-MIB
|
||||
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
RowPointer
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
hh3cTeTunnel MODULE-IDENTITY
|
||||
LAST-UPDATED "201103240948Z" -- March 24, 2011 at 09:48 GMT
|
||||
ORGANIZATION
|
||||
"New H3C Tech. Co., Ltd."
|
||||
CONTACT-INFO
|
||||
"Platform Team New H3C Tech. Co., Ltd.
|
||||
Hai-Dian District Beijing P.R. China
|
||||
http://www.h3c.com
|
||||
Zip:100085"
|
||||
DESCRIPTION
|
||||
"This MIB contains managed object definitions for the
|
||||
Multiprotocol Label Switching (MPLS) Te Tunnel."
|
||||
::= { hh3cCommon 115 }
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
|
||||
hh3cTeTunnelScalars OBJECT IDENTIFIER ::= { hh3cTeTunnel 1 }
|
||||
|
||||
hh3cTeTunnelMaxTunnelIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The max value of tunnel id is permitted configure on the device."
|
||||
::= { hh3cTeTunnelScalars 1 }
|
||||
|
||||
hh3cTeTunnelObjects OBJECT IDENTIFIER ::= { hh3cTeTunnel 2 }
|
||||
|
||||
hh3cTeTunnelStaticCrlspTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF Hh3cTeTunnelStaticCrlspEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information for static-crlsp, and through this
|
||||
to get detail information about this static-crlsp. Only support
|
||||
transit LSR and egress LSR."
|
||||
::= { hh3cTeTunnelObjects 1 }
|
||||
|
||||
hh3cTeTunnelStaticCrlspEntry OBJECT-TYPE
|
||||
SYNTAX Hh3cTeTunnelStaticCrlspEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry in this table describes static-crlsp information."
|
||||
INDEX { hh3cTeTunnelStaticCrlspInLabel }
|
||||
::= { hh3cTeTunnelStaticCrlspTable 1 }
|
||||
|
||||
Hh3cTeTunnelStaticCrlspEntry ::=
|
||||
SEQUENCE {
|
||||
hh3cTeTunnelStaticCrlspInLabel
|
||||
MplsLabel,
|
||||
hh3cTeTunnelStaticCrlspName
|
||||
OCTET STRING,
|
||||
hh3cTeTunnelStaticCrlspStatus
|
||||
INTEGER,
|
||||
hh3cTeTunnelStaticCrlspRole
|
||||
INTEGER,
|
||||
hh3cTeTunnelStaticCrlspXCPointer
|
||||
RowPointer
|
||||
}
|
||||
|
||||
hh3cTeTunnelStaticCrlspInLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is unique label value that manualy assigned. Uniquely
|
||||
identifies a static-crlsp. Managers should use this to obtain
|
||||
detail static-crlsp information."
|
||||
::= { hh3cTeTunnelStaticCrlspEntry 1 }
|
||||
|
||||
hh3cTeTunnelStaticCrlspName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..15))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unique name assigned to the static-crlsp."
|
||||
::= { hh3cTeTunnelStaticCrlspEntry 2 }
|
||||
|
||||
hh3cTeTunnelStaticCrlspStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
up(1),
|
||||
down(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the actual status of this static-crlsp,
|
||||
The value must be up when the static-crlsp status is up and
|
||||
the value must be down when the static-crlsp status is down."
|
||||
::= { hh3cTeTunnelStaticCrlspEntry 3 }
|
||||
|
||||
hh3cTeTunnelStaticCrlspRole OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
transit(1),
|
||||
tail(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicate the role of this static-crlsp. This value must
|
||||
be transit at transit point of the tunnel, and tail at
|
||||
terminating point of the tunnel."
|
||||
::= { hh3cTeTunnelStaticCrlspEntry 4 }
|
||||
|
||||
hh3cTeTunnelStaticCrlspXCPointer OBJECT-TYPE
|
||||
SYNTAX RowPointer
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This pointer unique identify a row of mplsXCTable.
|
||||
This value should be zeroDotZero when the static-crlsp
|
||||
is down. The mplsXCTable identifies the segments that
|
||||
compose this tunnel, their characteristics, and relationships
|
||||
to each other."
|
||||
::= { hh3cTeTunnelStaticCrlspEntry 5 }
|
||||
|
||||
hh3cTeTunnelCoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF Hh3cTeTunnelCoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information for Co-routed reverse crlsp and
|
||||
infomation of Co-routed bidirectional Tunnel Interface.
|
||||
If hh3cCorouteTunnelLspInstance is zero, to obtain infomation of
|
||||
Co-routed bidirectional Tunnel Interface, otherwise to obtain
|
||||
Co-routed reverse crlsp infomation."
|
||||
::= { hh3cTeTunnelObjects 2 }
|
||||
|
||||
hh3cTeTunnelCoEntry OBJECT-TYPE
|
||||
SYNTAX Hh3cTeTunnelCoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry in this table describes Co-routed infomation of
|
||||
bidirectional Tunnel Interface and reserver lsp information."
|
||||
INDEX { hh3cTeTunnelCoIndex, hh3cTeTunnelCoLspInstance, hh3cTeTunnelCoIngressLSRId, hh3cTeTunnelCoEgressLSRId }
|
||||
::= { hh3cTeTunnelCoTable 1 }
|
||||
|
||||
Hh3cTeTunnelCoEntry ::=
|
||||
SEQUENCE {
|
||||
hh3cTeTunnelCoIndex
|
||||
MplsTunnelIndex,
|
||||
hh3cTeTunnelCoLspInstance
|
||||
MplsTunnelInstanceIndex,
|
||||
hh3cTeTunnelCoIngressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hh3cTeTunnelCoEgressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hh3cTeTunnelCoBiMode
|
||||
INTEGER,
|
||||
hh3cTeTunnelCoReverseLspInstance
|
||||
MplsTunnelInstanceIndex,
|
||||
hh3cTeTunnelCoReverseLspXCPointer
|
||||
RowPointer
|
||||
}
|
||||
|
||||
hh3cTeTunnelCoIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Uniquely identifies a set of tunnel instances between a pair
|
||||
of ingress and egress LSRs that specified at originating point.
|
||||
This value should be equal to the value signaled in the
|
||||
Tunnel Id of the Session object."
|
||||
::= { hh3cTeTunnelCoEntry 1 }
|
||||
|
||||
hh3cTeTunnelCoLspInstance OBJECT-TYPE
|
||||
SYNTAX MplsTunnelInstanceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When obtain infomation of Co-routed bidirectional Tunnel Interface,
|
||||
this vlaue should be zero. And this value must be LspID to obtain
|
||||
reverse crlsp information. Values greater than 0, but less than or
|
||||
equal to 65535, should be useless."
|
||||
::= { hh3cTeTunnelCoEntry 2 }
|
||||
|
||||
hh3cTeTunnelCoIngressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity the ingress LSR associated with this tunnel instance.
|
||||
This vlaue is equal to the LsrID of originating endpoint."
|
||||
::= { hh3cTeTunnelCoEntry 3 }
|
||||
|
||||
hh3cTeTunnelCoEgressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity of the egress LSR associated with this tunnel instance.
|
||||
This vlaue is equal to the LsrID of terminating point."
|
||||
::= { hh3cTeTunnelCoEntry 4 }
|
||||
|
||||
hh3cTeTunnelCoBiMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
coroutedActive(1),
|
||||
coroutedPassive(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This vlaue indicated the bidirection mode of tunnel interface.
|
||||
The valuemust be coroutedActive at the originating point of the
|
||||
tunnel and coroutedPassive at the terminating point."
|
||||
::= { hh3cTeTunnelCoEntry 5 }
|
||||
|
||||
hh3cTeTunnelCoReverseLspInstance OBJECT-TYPE
|
||||
SYNTAX MplsTunnelInstanceIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated the reverse lsp instance, and
|
||||
should be equal to obverse lsp instance."
|
||||
::= { hh3cTeTunnelCoEntry 6 }
|
||||
|
||||
hh3cTeTunnelCoReverseLspXCPointer OBJECT-TYPE
|
||||
SYNTAX RowPointer
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This pointer unique index to mplsXCTable of the reverse lsp.
|
||||
The mplsXCTable identifies the segments that compose this tunnel,
|
||||
their characteristics, and relationships to each other. A
|
||||
value of zeroDotZero indicate that there is no crlsp assigned
|
||||
to this."
|
||||
::= { hh3cTeTunnelCoEntry 7 }
|
||||
|
||||
hh3cTeTunnelPsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF Hh3cTeTunnelPsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table defines some objects for managers to obtain
|
||||
TE tunnel Protection Switching group current status information."
|
||||
::= { hh3cTeTunnelObjects 3 }
|
||||
|
||||
hh3cTeTunnelPsEntry OBJECT-TYPE
|
||||
SYNTAX Hh3cTeTunnelPsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry in this table describes TE tunnel Protection
|
||||
Switching group infromation."
|
||||
INDEX { hh3cTeTunnelPsIndex, hh3cTeTunnelPsIngressLSRId, hh3cTeTunnelPsEgressLSRId }
|
||||
::= { hh3cTeTunnelPsTable 1 }
|
||||
|
||||
Hh3cTeTunnelPsEntry ::=
|
||||
SEQUENCE {
|
||||
hh3cTeTunnelPsIndex
|
||||
MplsTunnelIndex,
|
||||
hh3cTeTunnelPsIngressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hh3cTeTunnelPsEgressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hh3cTeTunnelPsProtectIndex
|
||||
MplsTunnelIndex,
|
||||
hh3cTeTunnelPsProtectIngressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hh3cTeTunnelPsProtectEgressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hh3cTeTunnelPsProtectType
|
||||
INTEGER,
|
||||
hh3cTeTunnelPsRevertiveMode
|
||||
INTEGER,
|
||||
hh3cTeTunnelPsWtrTime
|
||||
Unsigned32,
|
||||
hh3cTeTunnelPsHoldOffTime
|
||||
Unsigned32,
|
||||
hh3cTeTunnelPsSwitchMode
|
||||
INTEGER,
|
||||
hh3cTeTunnelPsWorkPathStatus
|
||||
INTEGER,
|
||||
hh3cTeTunnelPsProtectPathStatus
|
||||
INTEGER,
|
||||
hh3cTeTunnelPsSwitchResult
|
||||
INTEGER
|
||||
}
|
||||
|
||||
hh3cTeTunnelPsIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Uniquely identifies a TE tunnel Protection Switching group
|
||||
instance. This value must be equal to the tunnel id of work
|
||||
tunnel instance."
|
||||
::= { hh3cTeTunnelPsEntry 1 }
|
||||
|
||||
hh3cTeTunnelPsIngressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity the ingress LSR associated with work tunnel instance."
|
||||
::= { hh3cTeTunnelPsEntry 2 }
|
||||
|
||||
hh3cTeTunnelPsEgressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity of the egress LSR associated with work tunnel instance."
|
||||
::= { hh3cTeTunnelPsEntry 3 }
|
||||
|
||||
hh3cTeTunnelPsProtectIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Uniquely identifies a TE tunnel Protection Switching
|
||||
group instance. This value must be equal to the tunnel
|
||||
id of TE tunnel Protection Switching group instance."
|
||||
::= { hh3cTeTunnelPsEntry 4 }
|
||||
|
||||
hh3cTeTunnelPsProtectIngressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity the ingress LSR associated with TE tunnel
|
||||
Protection Switching group instance."
|
||||
::= { hh3cTeTunnelPsEntry 5 }
|
||||
|
||||
hh3cTeTunnelPsProtectEgressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity of the egress LSR associated with TE tunnel
|
||||
Protection Switching group instance."
|
||||
::= { hh3cTeTunnelPsEntry 6 }
|
||||
|
||||
hh3cTeTunnelPsProtectType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
oneToOne(1),
|
||||
onePlusOne(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated TE tunnel Protection Switching group
|
||||
type. The default value is oneToOne."
|
||||
DEFVAL { oneToOne }
|
||||
::= { hh3cTeTunnelPsEntry 7 }
|
||||
|
||||
hh3cTeTunnelPsRevertiveMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
revertive(1),
|
||||
noRevertive(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated protect switch mode. The value must be
|
||||
revertive or nonRevertive, default value is revertive.
|
||||
"
|
||||
DEFVAL { revertive }
|
||||
::= { hh3cTeTunnelPsEntry 8 }
|
||||
|
||||
hh3cTeTunnelPsWtrTime OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..60)
|
||||
UNITS "30 seconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The cycle time that switch to protect tunnel."
|
||||
DEFVAL { 24 }
|
||||
::= { hh3cTeTunnelPsEntry 9 }
|
||||
|
||||
hh3cTeTunnelPsHoldOffTime OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..20)
|
||||
UNITS "500ms"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value is switchback delay time. When detected the work path
|
||||
fault, switch to protect path after this time."
|
||||
DEFVAL { 0 }
|
||||
::= { hh3cTeTunnelPsEntry 10 }
|
||||
|
||||
hh3cTeTunnelPsSwitchMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
uniDirectional(1),
|
||||
biDirectional(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated TE tunnel Protection Switching
|
||||
group switch mode."
|
||||
DEFVAL { uniDirectional }
|
||||
::= { hh3cTeTunnelPsEntry 11 }
|
||||
|
||||
hh3cTeTunnelPsWorkPathStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(1),
|
||||
noDefect(2),
|
||||
inDefect(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicates work path status. none, noDefect, inDefect
|
||||
will be used."
|
||||
::= { hh3cTeTunnelPsEntry 12 }
|
||||
|
||||
hh3cTeTunnelPsProtectPathStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(1),
|
||||
noDefect(2),
|
||||
inDefect(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicates protect path status. none, noDefect,
|
||||
inDefect(3) will be used."
|
||||
::= { hh3cTeTunnelPsEntry 13 }
|
||||
|
||||
hh3cTeTunnelPsSwitchResult OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
workPath(1),
|
||||
protectPath(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated current using path is work path or protect
|
||||
path."
|
||||
::= { hh3cTeTunnelPsEntry 14 }
|
||||
|
||||
hh3cTeTunnelNotifications OBJECT IDENTIFIER ::= { hh3cTeTunnel 3 }
|
||||
|
||||
hh3cTeTunnelNotificationsPrefix OBJECT IDENTIFIER ::= { hh3cTeTunnelNotifications 0 }
|
||||
|
||||
hh3cTeTunnelPsSwitchWtoP NOTIFICATION-TYPE
|
||||
OBJECTS { hh3cTeTunnelPsWorkPathStatus, hh3cTeTunnelPsProtectPathStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is generated when protect workgroup switch from
|
||||
work tunnel to protect tunnel."
|
||||
::= { hh3cTeTunnelNotificationsPrefix 1 }
|
||||
|
||||
hh3cTeTunnelPsSwitchPtoW NOTIFICATION-TYPE
|
||||
OBJECTS { hh3cTeTunnelPsWorkPathStatus, hh3cTeTunnelPsProtectPathStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is generated when protect workgroup switch from
|
||||
protect tunnel to work tunnel."
|
||||
::= { hh3cTeTunnelNotificationsPrefix 2 }
|
||||
|
||||
hh3cTeTunnelConformance OBJECT IDENTIFIER ::= { hh3cTeTunnel 4 }
|
||||
|
||||
hh3cTeTunnelCompliances OBJECT IDENTIFIER ::= { hh3cTeTunnelConformance 1 }
|
||||
|
||||
hh3cTeTunnelCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for SNMP."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { hh3cTeTunnelNotificationsGroup, hh3cTeTunnelScalarsGroup, hh3cTeTunnelStaticCrlspGroup, hh3cTeTunnelCorouteGroup, hh3cTeTunnelPsGroup
|
||||
}
|
||||
::= { hh3cTeTunnelCompliances 1 }
|
||||
|
||||
hh3cTeTunnelGroups OBJECT IDENTIFIER ::= { hh3cTeTunnelConformance 2 }
|
||||
|
||||
hh3cTeTunnelNotificationsGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { hh3cTeTunnelPsSwitchPtoW, hh3cTeTunnelPsSwitchWtoP }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This group contains MPLS Te Tunnel traps."
|
||||
::= { hh3cTeTunnelGroups 1 }
|
||||
|
||||
hh3cTeTunnelScalarsGroup OBJECT-GROUP
|
||||
OBJECTS { hh3cTeTunnelMaxTunnelIndex }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Scalar object needed to implement MPLS te tunnels."
|
||||
::= { hh3cTeTunnelGroups 2 }
|
||||
|
||||
hh3cTeTunnelStaticCrlspGroup OBJECT-GROUP
|
||||
OBJECTS { hh3cTeTunnelStaticCrlspName, hh3cTeTunnelStaticCrlspStatus, hh3cTeTunnelStaticCrlspRole, hh3cTeTunnelStaticCrlspXCPointer }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects for quering static-crlsp information."
|
||||
::= { hh3cTeTunnelGroups 3 }
|
||||
|
||||
hh3cTeTunnelCorouteGroup OBJECT-GROUP
|
||||
OBJECTS { hh3cTeTunnelCoBiMode, hh3cTeTunnelCoReverseLspInstance, hh3cTeTunnelCoReverseLspXCPointer }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects for quering Co-routed reverse crlsp information."
|
||||
::= { hh3cTeTunnelGroups 4 }
|
||||
|
||||
hh3cTeTunnelPsGroup OBJECT-GROUP
|
||||
OBJECTS { hh3cTeTunnelPsProtectIndex, hh3cTeTunnelPsProtectIngressLSRId, hh3cTeTunnelPsProtectEgressLSRId, hh3cTeTunnelPsProtectType, hh3cTeTunnelPsRevertiveMode,
|
||||
hh3cTeTunnelPsWtrTime, hh3cTeTunnelPsHoldOffTime, hh3cTeTunnelPsSwitchMode, hh3cTeTunnelPsWorkPathStatus, hh3cTeTunnelPsProtectPathStatus,
|
||||
hh3cTeTunnelPsSwitchResult }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects for quering protect workgroup information."
|
||||
::= { hh3cTeTunnelGroups 5 }
|
||||
|
||||