Initial commit
This commit is contained in:
		
							
								
								
									
										869
									
								
								MIBS/dasan/SLE-MPLS-TP-LPS-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										869
									
								
								MIBS/dasan/SLE-MPLS-TP-LPS-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,869 @@
 | 
			
		||||
--
 | 
			
		||||
-- sle-mpls-tp-lps-mib.mib
 | 
			
		||||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0  Build 88
 | 
			
		||||
-- Tuesday, January 12, 2016 at 11:21:30
 | 
			
		||||
--
 | 
			
		||||
 | 
			
		||||
	SLE-MPLS-TP-LPS-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 
 | 
			
		||||
		IMPORTS
 | 
			
		||||
			sleMgmt			
 | 
			
		||||
				FROM DASAN-SMI			
 | 
			
		||||
			SleControlStatusType, SleControlRequestResultType			
 | 
			
		||||
				FROM SLE-TC-MIB			
 | 
			
		||||
			TimeTicks, Unsigned32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, 
 | 
			
		||||
			OBJECT-IDENTITY			
 | 
			
		||||
				FROM SNMPv2-SMI;
 | 
			
		||||
	
 | 
			
		||||
	
 | 
			
		||||
		sleMplsTpLps MODULE-IDENTITY 
 | 
			
		||||
			LAST-UPDATED "201510070000Z"		-- October 07, 2015 at 00:00 GMT
 | 
			
		||||
			ORGANIZATION 
 | 
			
		||||
				"Multiprotocol Label Switching (MplsTp) Working Group"
 | 
			
		||||
			CONTACT-INFO 
 | 
			
		||||
				"Gyerok Kwon 
 | 
			
		||||
				Dasan Networks
 | 
			
		||||
				Email:  grkwon@dasannetworks.com
 | 
			
		||||
				
 | 
			
		||||
				Kantharaj B M
 | 
			
		||||
				Dasan Networks
 | 
			
		||||
				Email:  kanth@dasannetworks.com
 | 
			
		||||
				
 | 
			
		||||
				DongChel Shin (Chris)
 | 
			
		||||
				Dasan Networks
 | 
			
		||||
				Email:  dchshin@dasannetworks.com
 | 
			
		||||
				
 | 
			
		||||
				Comments about this document should be emailed
 | 
			
		||||
				directly to the Dasan support email ID at
 | 
			
		||||
				support@dasannetworks.com."
 | 
			
		||||
			DESCRIPTION 
 | 
			
		||||
				"This management information module supports the
 | 
			
		||||
				configuration and management of MplsTp TP linear
 | 
			
		||||
				protection groups. "
 | 
			
		||||
			REVISION "201207150000Z"		-- July 15, 2012 at 00:00 GMT
 | 
			
		||||
			DESCRIPTION 
 | 
			
		||||
				"MplsTp Protection Switching Group objects for LSP MEPs"
 | 
			
		||||
			::= { sleMpls 18 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
	
 | 
			
		||||
	
 | 
			
		||||
--
 | 
			
		||||
-- Node definitions
 | 
			
		||||
--
 | 
			
		||||
	
 | 
			
		||||
		sleMpls OBJECT-IDENTITY
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION 
 | 
			
		||||
				"SLE MplsTp."
 | 
			
		||||
			::= { sleMgmt 16 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfg OBJECT IDENTIFIER ::= { sleMplsTpLps 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoTable OBJECT-TYPE
 | 
			
		||||
			SYNTAX SEQUENCE OF SleMplsTpLpsCfgInfoEntry
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This table lists the sleMplsTp linear protection groups that
 | 
			
		||||
				have been configured on the system."
 | 
			
		||||
			::= { sleMplsTpLpsCfg 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoEntry OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleMplsTpLpsCfgInfoEntry
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"A conceptual row in the sleMplsTpLpsCfgInfoTable."
 | 
			
		||||
			INDEX { sleMplsTpLpsCfgInfoGroupIndex }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoTable 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		SleMplsTpLpsCfgInfoEntry ::=
 | 
			
		||||
			SEQUENCE { 
 | 
			
		||||
				sleMplsTpLpsCfgInfoGroupIndex
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsCfgInfoGroupName
 | 
			
		||||
					OCTET STRING,
 | 
			
		||||
				sleMplsTpLpsCfgInfoMode
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpLpsCfgInfoProtectionScheme
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpLpsCfgInfoRevertive
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpLpsCfgInfoWtr
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsCfgInfoContinualTxInterval
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsCfgInfoRapidTxInterval
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsCfgInfoSwitchOver
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpLpsCfgInfoLockOut
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpLpsCfgInfoHoldOffTimer
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsCfgInfoActivePath
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpLpsCfgInfoOperationState
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpLpsCfgInfoEventStatus
 | 
			
		||||
					INTEGER
 | 
			
		||||
			 }
 | 
			
		||||
 | 
			
		||||
		sleMplsTpLpsCfgInfoGroupIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (0..65535)
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Index for the conceptual row identifying a protection group."
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoGroupName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING (SIZE (1..128))
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Textual name represents the sleMplsTp tp protection group.
 | 
			
		||||
				Each Protection Group is identified by a unique
 | 
			
		||||
				protection group name. "
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoMode OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				onePlusOne(1),
 | 
			
		||||
				oneColonOne(2),
 | 
			
		||||
				oneColonN(3)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The architectural mode of the Protection group. This can
 | 
			
		||||
				either be 1+1, 1:1, 1:n.
 | 
			
		||||
				
 | 
			
		||||
				1+1
 | 
			
		||||
				
 | 
			
		||||
				In the 1+1 protection scheme, a fully dedicated
 | 
			
		||||
				protection entity is allocated. Data traffic is copied
 | 
			
		||||
				and fed at the source to both the working and the
 | 
			
		||||
				protection entities.  The traffic on the working and the
 | 
			
		||||
				protection entities is transmitted simultaneously to
 | 
			
		||||
				the sink of the protection domain, where selection
 | 
			
		||||
				between the working and protection entities is performed
 | 
			
		||||
				
 | 
			
		||||
				1:1
 | 
			
		||||
				
 | 
			
		||||
				In the 1:1 scheme, a protection path is allocated to
 | 
			
		||||
				protect against a defect, failure, or a degradation in a
 | 
			
		||||
				working path. In normal conditions, data traffic is
 | 
			
		||||
				transmitted over the working entity, while the
 | 
			
		||||
				protection entity functions in the idle state. If there
 | 
			
		||||
				is a defect on the working entity or a specific
 | 
			
		||||
				administrative request, traffic is switched to the
 | 
			
		||||
				protection entity.
 | 
			
		||||
				
 | 
			
		||||
				1:n
 | 
			
		||||
				
 | 
			
		||||
				In case of 1:n linear protection, one protection entity
 | 
			
		||||
				is allocated to protect n working entities. The protection
 | 
			
		||||
				entity might not have sufficient resources to protect all the
 | 
			
		||||
				working entities that may be affected by fault conditions at a
 | 
			
		||||
				specific time. In this case, in order to guaranteed
 | 
			
		||||
				protection, the protection entity should support enough
 | 
			
		||||
				capacity and bandwidth to protect any of the n working
 | 
			
		||||
				entities."
 | 
			
		||||
			DEFVAL { oneColonOne }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 3 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoProtectionScheme OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				bidirectional(1),
 | 
			
		||||
				unidirectional(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The object represents the operational scheme of
 | 
			
		||||
				protection switching group. The protection scheme may
 | 
			
		||||
				either be unidirectional or bidirectional.
 | 
			
		||||
				
 | 
			
		||||
				bidirectional
 | 
			
		||||
				In bidirectional protection scheme, both the directions
 | 
			
		||||
				will be switched simultaneously even if the fault
 | 
			
		||||
				applies to only one direction of the path.
 | 
			
		||||
				
 | 
			
		||||
				unidirectional
 | 
			
		||||
				In unidirectional protection scheme protection switching
 | 
			
		||||
				will be performed independently for each direction of a
 | 
			
		||||
				bidirectional transport path
 | 
			
		||||
				
 | 
			
		||||
				This object may not be modified if the associated
 | 
			
		||||
				sleMplsTpLpsCfgRowStatus object is equal to active(1). "
 | 
			
		||||
			DEFVAL { bidirectional }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 4 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoRevertive OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				nonrevertive(1),
 | 
			
		||||
				revertive(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object represents the reversion mode of the Linear
 | 
			
		||||
				Protection Switching group. The reversion mode of
 | 
			
		||||
				protection mechanism may be either revertive or
 | 
			
		||||
				non-revertive.
 | 
			
		||||
				
 | 
			
		||||
				In non-revertive mode, after a service has been
 | 
			
		||||
				recovered, traffic will be forwarded on the recovery
 | 
			
		||||
				path revertive
 | 
			
		||||
				In revertive mode, after a service has been
 | 
			
		||||
				recovered, traffic will be redirected back onto the
 | 
			
		||||
				original working path."
 | 
			
		||||
			DEFVAL { nonrevertive }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 5 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoWtr OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (0..720)
 | 
			
		||||
			UNITS "seconds"
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object hold the Wait To Restore timer value in
 | 
			
		||||
				seconds.
 | 
			
		||||
				The WTR timer is used to delay reversion of PSC state
 | 
			
		||||
				to Normal state when recovering from a failure
 | 
			
		||||
				condition on the working path when the protection
 | 
			
		||||
				domain is configured for revertive behavior
 | 
			
		||||
				
 | 
			
		||||
				This object may not be modified if the associated
 | 
			
		||||
				sleMplsTpLpsCfgRowStatus object is equal to active(1)."
 | 
			
		||||
			DEFVAL { 300 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 6 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoContinualTxInterval OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..20)
 | 
			
		||||
			UNITS "seconds"
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The Continual Tx Time in Seconds. Represents the time 
 | 
			
		||||
				interval to send the continual LPS packet to the other 
 | 
			
		||||
				end based on the current state."
 | 
			
		||||
			DEFVAL { 5 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 7 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoRapidTxInterval OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1000..20000)
 | 
			
		||||
			UNITS "micro-seconds"
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The Rapid Tx interval in micro-Seconds. Represents the time
 | 
			
		||||
				interval to send the LPS packet to the other end, when
 | 
			
		||||
				there is a change in state of Linear Protection domain due
 | 
			
		||||
				to local input. The default value is 3.3 milli-seconds
 | 
			
		||||
				which is 3300 micro-seconds"
 | 
			
		||||
			DEFVAL { 3300 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 8 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoSwitchOver OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				none(0),
 | 
			
		||||
				forced(1),
 | 
			
		||||
				manual(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				" this object used for switch the traffic to the back up path."
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 9 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoLockOut OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				enable(1),
 | 
			
		||||
				disable(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"this is object is used for preventing the swith traffic by the protection path."
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 10 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoHoldOffTimer OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				" this object used for show the hold off timer."
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 11 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoActivePath OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				primary(1),
 | 
			
		||||
				backup(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object say which path is Active ."
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 12 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoOperationState OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				up(1),
 | 
			
		||||
				down(0)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"this  object says Operational Status of LPS.    The LPS is between PE to PE."
 | 
			
		||||
			DEFVAL { 0 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 13 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgInfoEventStatus OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				normal(1),
 | 
			
		||||
				protection(2),
 | 
			
		||||
				localForce(3),
 | 
			
		||||
				localManual(4),
 | 
			
		||||
				localSgfProtection(5),
 | 
			
		||||
				localSgfWorking(6),
 | 
			
		||||
				localWtr(7),
 | 
			
		||||
				localLock(8),
 | 
			
		||||
				localClrSfProtection(9),
 | 
			
		||||
				localClrSfWorking(10),
 | 
			
		||||
				localClrEvent(11),
 | 
			
		||||
				remoteLock(12),
 | 
			
		||||
				remoteForce(13),
 | 
			
		||||
				remoteManual(14),
 | 
			
		||||
				remoteSfProtect(15),
 | 
			
		||||
				remoteSfWork(16),
 | 
			
		||||
				remoteWtr(17),
 | 
			
		||||
				remoteNoReq(18),
 | 
			
		||||
				remoteNotRevert(19),
 | 
			
		||||
				noRequest(20),
 | 
			
		||||
				remoteSdWork(21),
 | 
			
		||||
				remoteSdProtection(22),
 | 
			
		||||
				remoteExesWork(23),
 | 
			
		||||
				remoteExesProtect(24),
 | 
			
		||||
				remoteRrReqWork(25),
 | 
			
		||||
				remoteRrReqProtec(26),
 | 
			
		||||
				remoteNoReqWork(27),
 | 
			
		||||
				remoteNoReqProtection(28),
 | 
			
		||||
				localSdProtection(29),
 | 
			
		||||
				localClearSdProtection(30),
 | 
			
		||||
				localSdWorking(31),
 | 
			
		||||
				localClearSdWorking(32),
 | 
			
		||||
				localExercise(33)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This  is object says  EVENT Status of LPS protection ."
 | 
			
		||||
			DEFVAL { 0 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgInfoEntry 14 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControl OBJECT IDENTIFIER ::= { sleMplsTpLpsCfg 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlRequest OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				createSleMplsTpLpsCfgEntry(1),
 | 
			
		||||
				deleteSleMplsTpLpsCfgEntry(2),
 | 
			
		||||
				setSleMplsTpLpsCfgControProtectionScheme(3),
 | 
			
		||||
				unsetSleMplsTpLpsCfgControProtectionScheme(4),
 | 
			
		||||
				setSleMplsLpsTpCfgControlRevertive(5),
 | 
			
		||||
				setSleMplsLpsTpCfgControlWaitToRestoreset(6),
 | 
			
		||||
				unsetSleMplsTpLpsCfgControlWaitToRestoreset(7),
 | 
			
		||||
				setSleMplsLpsTpCfgControlContinualTxInterval(8),
 | 
			
		||||
				unsetSleMplsTpLpsCfgControlContinualTxInterval(9),
 | 
			
		||||
				setSleMplsLpsTpCfgControlRapidTxInterval(10),
 | 
			
		||||
				unsetSleMplsTpLpsCfgControlRapidTxInterval(11),
 | 
			
		||||
				setSleMplsLpsTpCfgControlSwitchover(12),
 | 
			
		||||
				unsetSleMplsTpLpsCfgControlSwitchover(13),
 | 
			
		||||
				setSleMplsTpLpsCfgControlLockOut(14),
 | 
			
		||||
				unsetSleMplsTpLpsTpCfgControlLockOut(15),
 | 
			
		||||
				setSleMplsTpLpsCfgControlHoldOffTimer(16),
 | 
			
		||||
				unSetSleMplsTpLpsCfgControlHoldOffTimer(17)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"the configuration commands, and user can configure functions 
 | 
			
		||||
				via setting this entry as proper value."
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlStatus OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleControlStatusType
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"status of user command. User have to check this value as 
 | 
			
		||||
				.busy. or .idle. before do setRequest."
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlTimer OBJECT-TYPE
 | 
			
		||||
			SYNTAX Gauge32
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"the wait-time until setRequest end. In case of short-time command, this value is 0"
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 3 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlTimeStamp OBJECT-TYPE
 | 
			
		||||
			SYNTAX TimeTicks
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"the time stamp of the last command. (don.t care)"
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 4 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlReqResult OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleControlRequestResultType
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Result of the last command."
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 5 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlGroupName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING (SIZE (1..32))
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Textual name represents the sleMplsTp tp protection group.
 | 
			
		||||
				Each Protection Group is identified by a unique
 | 
			
		||||
				protection group name. "
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 6 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlMode OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				onePlusOne(1),
 | 
			
		||||
				oneColonOne(2),
 | 
			
		||||
				oneColonN(3)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The architectural mode of the Protection group. This can
 | 
			
		||||
				either be 1+1, 1:1, 1:n.
 | 
			
		||||
				
 | 
			
		||||
				1+1
 | 
			
		||||
				
 | 
			
		||||
				In the 1+1 protection scheme, a fully dedicated
 | 
			
		||||
				protection entity is allocated. Data traffic is copied
 | 
			
		||||
				
 | 
			
		||||
				
 | 
			
		||||
				
 | 
			
		||||
				and fed at the source to both the working and the
 | 
			
		||||
				protection entities.  The traffic on the working and the
 | 
			
		||||
				protection entities is transmitted simultaneously to
 | 
			
		||||
				the sink of the protection domain, where selection
 | 
			
		||||
				between the working and protection entities is performed
 | 
			
		||||
				
 | 
			
		||||
				1:1
 | 
			
		||||
				
 | 
			
		||||
				In the 1:1 scheme, a protection path is allocated to
 | 
			
		||||
				protect against a defect, failure, or a degradation in a
 | 
			
		||||
				working path. In normal conditions, data traffic is
 | 
			
		||||
				transmitted over the working entity, while the
 | 
			
		||||
				protection entity functions in the idle state. If there
 | 
			
		||||
				is a defect on the working entity or a specific
 | 
			
		||||
				administrative request, traffic is switched to the
 | 
			
		||||
				protection entity.
 | 
			
		||||
				
 | 
			
		||||
				1:n
 | 
			
		||||
				
 | 
			
		||||
				In case of 1:n linear protection, one protection entity
 | 
			
		||||
				is allocated to protect n working entities. The protection
 | 
			
		||||
				entity might not have sufficient resources to protect all the
 | 
			
		||||
				working entities that may be affected by fault conditions at a
 | 
			
		||||
				specific time. In this case, in order to guaranteed
 | 
			
		||||
				protection, the protection entity should support enough
 | 
			
		||||
				capacity and bandwidth to protect any of the n working
 | 
			
		||||
				entities."
 | 
			
		||||
			DEFVAL { oneColonOne }
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 7 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlProtectionScheme OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				bidirectional(1),
 | 
			
		||||
				unidirectional(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The object represents the operational scheme of
 | 
			
		||||
				protection switching group. The protection scheme may
 | 
			
		||||
				either be unidirectional or bidirectional.
 | 
			
		||||
				
 | 
			
		||||
				bidirectional
 | 
			
		||||
				In bidirectional protection scheme, both the directions
 | 
			
		||||
				will be switched simultaneously even if the fault
 | 
			
		||||
				applies to only one direction of the path.
 | 
			
		||||
				
 | 
			
		||||
				unidirectional
 | 
			
		||||
				In unidirectional protection scheme protection switching
 | 
			
		||||
				will be performed independently for each direction of a
 | 
			
		||||
				bidirectional transport path
 | 
			
		||||
				
 | 
			
		||||
				This object may not be modified if the associated
 | 
			
		||||
				sleMplsTpLpsCfgControlRowStatus object is equal to active(1). "
 | 
			
		||||
			DEFVAL { bidirectional }
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 8 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlRevertive OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				nonrevertive(1),
 | 
			
		||||
				revertive(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object represents the reversion mode of the Linear
 | 
			
		||||
				Protection Switching group. The reversion mode of
 | 
			
		||||
				protection mechanism may be either revertive or
 | 
			
		||||
				non-revertive.
 | 
			
		||||
				
 | 
			
		||||
				nonrevertive
 | 
			
		||||
				In non-revertive mode, after a service has been
 | 
			
		||||
				recovered, traffic will be forwarded on the recovery
 | 
			
		||||
				path
 | 
			
		||||
				
 | 
			
		||||
				revertive
 | 
			
		||||
				In revertive mode, after a service has been
 | 
			
		||||
				recovered, traffic will be redirected back onto the
 | 
			
		||||
				original working path."
 | 
			
		||||
			DEFVAL { nonrevertive }
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 9 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlWtr OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (0..720)
 | 
			
		||||
			UNITS "seconds"
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object hold the Wait To Restore timer value in
 | 
			
		||||
				seconds.
 | 
			
		||||
				The WTR timer is used to delay reversion of PSC state
 | 
			
		||||
				to Normal state when recovering from a failure
 | 
			
		||||
				condition on the working path when the protection
 | 
			
		||||
				domain is configured for revertive behavior
 | 
			
		||||
				
 | 
			
		||||
				This object may not be modified if the associated
 | 
			
		||||
				sleMplsTpLpsCfgControlRowStatus object is equal to active(1)."
 | 
			
		||||
			DEFVAL { 300 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 10 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlContinualTxInterval OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..20)
 | 
			
		||||
			UNITS "seconds"
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The Continual Tx Time in Seconds. Represents the time 
 | 
			
		||||
				interval to send the continual LPS packet to the other 
 | 
			
		||||
				end based on the current state."
 | 
			
		||||
			DEFVAL { 5 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 11 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlRapidTxInterval OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1000)
 | 
			
		||||
			UNITS "micro-seconds"
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The Rapid Tx interval in micro-Seconds. Represents the time
 | 
			
		||||
				interval to send the LPS packet to the other end, when
 | 
			
		||||
				there is a change in state of Linear Protection domain due
 | 
			
		||||
				to local input. The default value is 3.3 milli-seconds
 | 
			
		||||
				which is 3300 micro-seconds"
 | 
			
		||||
			DEFVAL { 3300 }
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 12 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlswitchOver OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				force(1),
 | 
			
		||||
				manual(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				" this object used for switch the traffic to the back up path."
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 13 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlLockOut OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				enable(1),
 | 
			
		||||
				disable(0)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"this is object is used for preventing the swith traffic by the protection path."
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 14 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsCfgControlHoldOffTimer OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the holdofftimer "
 | 
			
		||||
			::= { sleMplsTpLpsCfgControl 15 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfg OBJECT IDENTIFIER ::= { sleMplsTpLps 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgInfoTable OBJECT-TYPE
 | 
			
		||||
			SYNTAX SEQUENCE OF SleMplsTpLpsMeCfgInfoEntry
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This table lists Maintenance Association that have been
 | 
			
		||||
				configured in Protection groups."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfg 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgInfoEntry OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleMplsTpLpsMeCfgInfoEntry
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"A conceptual row in the sleMplsTpLpsMeCfgInfoTable."
 | 
			
		||||
			INDEX { sleMplsTpLpsMeCfgInfoMeIndex, sleMplsTpLpsMeCfgInfoMPId, sleMplsTpLspMeCfgInfoGroupIndex, sleMplsTpLpsMeCfgInfoMegIndex }
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgInfoTable 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		SleMplsTpLpsMeCfgInfoEntry ::=
 | 
			
		||||
			SEQUENCE { 
 | 
			
		||||
				sleMplsTpLpsMeCfgInfoMegIndex
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsMeCfgInfoMeIndex
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsMeCfgInfoMPId
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLspMeCfgInfoGroupIndex
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpLpsMeCfgInfoState
 | 
			
		||||
					INTEGER
 | 
			
		||||
			 }
 | 
			
		||||
 | 
			
		||||
		sleMplsTpLpsMeCfgInfoMegIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (0..65535)
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Uniquely identifies a maintenance entity index within
 | 
			
		||||
				a MEG."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgInfoEntry 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgInfoMeIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (0..65535)
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object denotes the ME name, each
 | 
			
		||||
				Maintenance Entity has unique name within MEG."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgInfoEntry 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgInfoMPId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..8191)
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Indicates the maintenance point index, used to create
 | 
			
		||||
				multiple MEPs in a node of single ME. The value of this
 | 
			
		||||
				object can be MEP index or MIP index. Managers should 
 | 
			
		||||
				obtain new values for row creation in this table by reading
 | 
			
		||||
				mplsOamIdMeMpIndexNext."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgInfoEntry 3 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLspMeCfgInfoGroupIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (0..65535)
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Textual name represents the sleMplsTp tp protection group.
 | 
			
		||||
				Each Protection Group is identified by a unique
 | 
			
		||||
				protection group name. "
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgInfoEntry 4 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgInfoState OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				primary(1),
 | 
			
		||||
				backup(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object represents the operational state of the ME
 | 
			
		||||
				as either primary or backup"
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgInfoEntry 5 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControl OBJECT IDENTIFIER ::= { sleMplsTpLpsMeCfg 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlRequest OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				createSleMplsTpLpsMeConfigEntry(1),
 | 
			
		||||
				deleteSleMplsTpLpsMeConfigEntry(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"the configuration commands, and user can configure functions via setting 
 | 
			
		||||
				this entry as proper value."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlStatus OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleControlStatusType
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"status of user command. User have to check this value as 
 | 
			
		||||
				.busy. or .idle. before do setRequest."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlTimer OBJECT-TYPE
 | 
			
		||||
			SYNTAX Gauge32
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"the wait-time until setRequest end. In case of short-time command, this value is 0"
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 3 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlTimeStamp OBJECT-TYPE
 | 
			
		||||
			SYNTAX TimeTicks
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"the time stamp of the last command. (don.t care)"
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 4 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlReqResult OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleControlRequestResultType
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Result of the last command."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 5 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlMegName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Uniquely identifies a maintenance entity index within
 | 
			
		||||
				a MEG"
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 6 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlMeName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object denotes the ME name, each
 | 
			
		||||
				Maintenance Entity has unique name within MEG."
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 7 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlMpId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION			" "
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 8 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlGroupName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object holds the Protection group index wherein
 | 
			
		||||
				this ME included in. If this ME is not part of a protection
 | 
			
		||||
				group this value is set to 0. "
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 9 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpLpsMeCfgControlState OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				primary(1),
 | 
			
		||||
				backup(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object represents the operational state of the ME
 | 
			
		||||
				as either primary or backup"
 | 
			
		||||
			::= { sleMplsTpLpsMeCfgControl 10 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
	
 | 
			
		||||
	END
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
-- sle-mpls-tp-lps-mib.mib
 | 
			
		||||
--
 | 
			
		||||
		Reference in New Issue
	
	Block a user