@ -0,0 +1,286 @@
|
||||
--
|
||||
-- sle-mpls-tp-node-mib.mib
|
||||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
||||
-- Tuesday, January 12, 2016 at 11:22:02
|
||||
--
|
||||
|
||||
SLE-MPLS-TP-NODE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
sleMgmt
|
||||
FROM DASAN-SMI
|
||||
MplsCcId, MplsIccId
|
||||
FROM MPLS-TC-EXT-STD-MIB
|
||||
mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId
|
||||
FROM MPLS-TE-STD-MIB
|
||||
SleControlStatusType, SleControlRequestResultType
|
||||
FROM SLE-TC-MIB
|
||||
zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
|
||||
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
|
||||
sleMplsTpNode MODULE-IDENTITY
|
||||
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
|
||||
ORGANIZATION
|
||||
"Multiprotocol Label Switching (MPLS) Working Group"
|
||||
CONTACT-INFO
|
||||
"Gyerok Kwon
|
||||
Dasan Networks
|
||||
Email: grkwon@dasannetworks.com
|
||||
|
||||
Kantharaj B M
|
||||
Dasan Networks
|
||||
Email: kanth@dasannetworks.com
|
||||
|
||||
DongChel Shin (Chris)
|
||||
Dasan Networks
|
||||
Email: dchshin@dasannetworks.com
|
||||
|
||||
Comments about this document should be emailed
|
||||
directly to the Dasan support email ID at
|
||||
support@dasannetworks.com."
|
||||
DESCRIPTION
|
||||
"Copyright (c) 2012 IETF Trust and the persons identified
|
||||
as the document authors. All rights reserved.
|
||||
|
||||
This MIB module contains generic object definitions for
|
||||
MPLS Traffic Engineering in transport networks."
|
||||
REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
|
||||
DESCRIPTION
|
||||
"MPLS_TP node configuration table"
|
||||
::= { sleMpls 13 }
|
||||
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
|
||||
sleMpls OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"SLE MPLS."
|
||||
::= { sleMgmt 16 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfg OBJECT IDENTIFIER ::= { sleMplsTpNode 1 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgInfo OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 1 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgInfoGlobalId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..4294967295)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the Global Operator Identifier.
|
||||
this object value should be zero when
|
||||
sleMplsTpNodeConfigInfoCcId and sleMplsTpNodeConfigInfoICcId
|
||||
is configured with non-null value."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgInfo 1 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgInfoItutCc OBJECT-TYPE
|
||||
SYNTAX MplsCcId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object allows the operator or service provider to
|
||||
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
||||
either for Ingress ID or Egress ID.
|
||||
|
||||
This object value should be zero when
|
||||
sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgInfo 2 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgInfoItutIcc OBJECT-TYPE
|
||||
SYNTAX MplsIccId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object allows the operator or service provider to
|
||||
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
||||
either for Ingress ID or Egress ID.
|
||||
|
||||
This object value should be zero when
|
||||
sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgInfo 3 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgInfoNodeId OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the Node_ID within the operator."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgInfo 4 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgInfoNodeType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
ietf(1),
|
||||
itut(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object value should be zero when
|
||||
sleMplsTpNodeConfigInfoGlobalId are assigned with non-zero value ."
|
||||
::= { sleMplsTpNodeCfgInfo 5 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControl OBJECT IDENTIFIER ::= { sleMplsTpNodeCfg 2 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlRequest OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
setMplsTpNode(1),
|
||||
unsetMplsTpNode(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object holds the possible read-write columns that can be
|
||||
modified in the TunnelExtNodeConfigTable table. For each read-write
|
||||
column of TunnelExtNodeConfigTable table, a Set Operation control
|
||||
value is added in this object."
|
||||
::= { sleMplsTpNodeCfgControl 1 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlStatus OBJECT-TYPE
|
||||
SYNTAX SleControlStatusType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object displays the status of the configuration done."
|
||||
::= { sleMplsTpNodeCfgControl 2 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlTimer OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is based on the SLE style where a timer is configured
|
||||
for every control table."
|
||||
::= { sleMplsTpNodeCfgControl 3 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlTimestamp OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the time at which the configuration is done."
|
||||
::= { sleMplsTpNodeCfgControl 4 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlReqResult OBJECT-TYPE
|
||||
SYNTAX SleControlRequestResultType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The standard result of the SET operation is stored here."
|
||||
::= { sleMplsTpNodeCfgControl 5 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlGlobalId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..4294967295)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the Global Operator Identifier.
|
||||
This object value should be zero when
|
||||
sleMplsTpNodeConfigControlIccId and sleMplsTpNodeConfigControlccId
|
||||
is configured with non-null value."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgControl 6 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlItutCc OBJECT-TYPE
|
||||
SYNTAX MplsCcId
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object allows the operator or service provider to
|
||||
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
||||
either for Ingress ID or Egress ID.
|
||||
|
||||
This object value should be zero when
|
||||
sleMplsTpNodeConfigControlGlobalId are assigned with
|
||||
non-zero value."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgControl 7 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlItutIcc OBJECT-TYPE
|
||||
SYNTAX MplsIccId
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object allows the operator or service provider to configure a
|
||||
unique MPLS-TP ITU-T Carrier Code (ICC) either for Ingress ID
|
||||
or Egress ID.
|
||||
|
||||
This object value should be zero when
|
||||
sleMplsTpNodeConfigControlGlobalId are assigned with non-zero
|
||||
value."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgControl 8 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlNodeId OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the Node_ID within the operator."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgControl 9 }
|
||||
|
||||
|
||||
sleMplsTpNodeCfgControlNodeType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
ietf(1),
|
||||
itut(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object allows the operator or service provider to
|
||||
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
|
||||
either for Ingress ID or Egress ID.
|
||||
|
||||
This object value should be zero when
|
||||
msleMplsTpNodeConfigControlGlobalId are assigned with non-zero
|
||||
value."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpNodeCfgControl 10 }
|
||||
|
||||
|
||||
|
||||
END
|
||||
|
||||
--
|
||||