Initial commit
This commit is contained in:
205
MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB
Normal file
205
MIBS/dasan/SLE-MPLS-TP-PRO-IF-MIB
Normal file
@ -0,0 +1,205 @@
|
||||
--
|
||||
-- sle-mpls-tp-pro-if-mib.mib
|
||||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
||||
-- Tuesday, January 12, 2016 at 14:08:09
|
||||
--
|
||||
|
||||
SLE-MPLS-TP-PRO-IF-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
sleMgmt
|
||||
FROM DASAN-SMI
|
||||
mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId
|
||||
FROM MPLS-TE-STD-MIB
|
||||
SleControlStatusType, SleControlRequestResultType
|
||||
FROM SLE-TC-MIB
|
||||
zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
|
||||
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
|
||||
sleMplsTpNode MODULE-IDENTITY
|
||||
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
|
||||
ORGANIZATION
|
||||
"Multiprotocol Label Switching (MPLS) Working Group"
|
||||
CONTACT-INFO
|
||||
"Gyerok Kwon
|
||||
Dasan Networks
|
||||
Email: grkwon@dasannetworks.com
|
||||
|
||||
Kantharaj B M
|
||||
Dasan Networks
|
||||
Email: kanth@dasannetworks.com
|
||||
|
||||
DongChel Shin (Chris)
|
||||
Dasan Networks
|
||||
Email: dchshin@dasannetworks.com
|
||||
|
||||
Comments about this document should be emailed
|
||||
directly to the Dasan support email ID at
|
||||
support@dasannetworks.com."
|
||||
DESCRIPTION
|
||||
"Copyright (c) 2012 IETF Trust and the persons identified
|
||||
as the document authors. All rights reserved.
|
||||
|
||||
This MIB module contains generic object definitions for
|
||||
MPLS Traffic Engineering in transport networks."
|
||||
REVISION "201207150000Z" -- July 15, 2012 at 00:00 GMT
|
||||
DESCRIPTION
|
||||
"MPLS_TP node configuration table"
|
||||
::= { sleMpls 13 }
|
||||
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
|
||||
sleMpls OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"SLE MPLS."
|
||||
::= { sleMgmt 16 }
|
||||
|
||||
|
||||
sleMplsTpProIf OBJECT IDENTIFIER ::= { sleMplsTpNode 2 }
|
||||
|
||||
|
||||
sleMplsTpProIfInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SleMplsTpProIfInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION " "
|
||||
::= { sleMplsTpProIf 1 }
|
||||
|
||||
|
||||
sleMplsTpProIfInfoEntry OBJECT-TYPE
|
||||
SYNTAX SleMplsTpProIfInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION " "
|
||||
INDEX { sleMplsTPProIfInfoIfIndex }
|
||||
::= { sleMplsTpProIfInfoTable 1 }
|
||||
|
||||
|
||||
SleMplsTpProIfInfoEntry ::=
|
||||
SEQUENCE {
|
||||
sleMplsTPProIfInfoIfIndex
|
||||
Unsigned32,
|
||||
sleMplsTPProIfInfoIpAddr
|
||||
IpAddress
|
||||
}
|
||||
|
||||
sleMplsTPProIfInfoIfIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..65535)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used in accommodating the bigger
|
||||
size Global_Node_ID and/or ICC with lower size LSR
|
||||
identifier in order to index the mplsTunnelTable.
|
||||
|
||||
The Local Identifier is configured between 1 and 16777215,
|
||||
as valid IP address range starts from 16777216(01.00.00.00).
|
||||
This range is chosen to identify the mplsTunnelTable's
|
||||
Ingress/Egress LSR-id is IP address or Local identifier,
|
||||
if the configured range is not IP address, administrator is
|
||||
expected to retrieve the complete information
|
||||
(Global_Node_ID or ICC) from mplsTunnelExtNodeConfigTable.
|
||||
This way, existing mplsTunnelTable is reused for
|
||||
bidirectional tunnel extensions for MPLS based transport networks.
|
||||
|
||||
This Local Identifier allows the administrator to assign
|
||||
a unique identifier to map Global_Node_ID and/or ICC."
|
||||
::= { sleMplsTpProIfInfoEntry 1 }
|
||||
|
||||
|
||||
sleMplsTPProIfInfoIpAddr OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION " "
|
||||
::= { sleMplsTpProIfInfoEntry 2 }
|
||||
|
||||
|
||||
sleMplsTpProIfControl OBJECT IDENTIFIER ::= { sleMplsTpProIf 2 }
|
||||
|
||||
|
||||
sleMplsTpProIfControlRequest OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
setMplsTpProIfIpAddr(1),
|
||||
unSetMplsTpProIfIpAddr(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object holds the possible read-write columns that
|
||||
can be modified in the TunnelExtNodeConfigTable table.
|
||||
For each read-write column of TunnelExtNodeConfigTable table,
|
||||
a Set Operation control value is added in this object."
|
||||
::= { sleMplsTpProIfControl 1 }
|
||||
|
||||
|
||||
sleMplsTpProIfControlStatus OBJECT-TYPE
|
||||
SYNTAX SleControlStatusType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object displays the status of the configuration done."
|
||||
::= { sleMplsTpProIfControl 2 }
|
||||
|
||||
|
||||
sleMplsTpProIfControlTimer OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is based on the SLE style where a timer is configured for every control table."
|
||||
::= { sleMplsTpProIfControl 3 }
|
||||
|
||||
|
||||
sleMplsTpProIfControlTimestamp OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the time at which the configuration is done."
|
||||
::= { sleMplsTpProIfControl 4 }
|
||||
|
||||
|
||||
sleMplsTpProIfControlReqResult OBJECT-TYPE
|
||||
SYNTAX SleControlRequestResultType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The standard result of the SET operation is stored here."
|
||||
::= { sleMplsTpProIfControl 5 }
|
||||
|
||||
|
||||
sleMplsTpProIfControlIfIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION " "
|
||||
::= { sleMplsTpProIfControl 6 }
|
||||
|
||||
|
||||
sleMplsTpProIfControlIpAddr OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the Global Operator Identifier."
|
||||
REFERENCE
|
||||
"MPLS-TP Identifiers [RFC6370]."
|
||||
::= { sleMplsTpProIfControl 7 }
|
||||
|
||||
|
||||
|
||||
END
|
||||
|
||||
--
|
||||
-- sle-mpls-tp-pro-if-mib.mib
|
||||
--
|
Reference in New Issue
Block a user