Initial commit
This commit is contained in:
152
MIBS/eltexmes23xx/ELTEX-MES
Normal file
152
MIBS/eltexmes23xx/ELTEX-MES
Normal file
@ -0,0 +1,152 @@
|
||||
--
|
||||
-- Eltex MES Ethernet Switches MIBs
|
||||
--
|
||||
-- Copyright (c) 2015, Eltex Ltd
|
||||
-- All rights reserved.
|
||||
--
|
||||
|
||||
ELTEX-MES DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
eltexLtd, elHardware
|
||||
FROM ELTEX-SMI-ACTUAL;
|
||||
|
||||
eltMes MODULE-IDENTITY
|
||||
LAST-UPDATED "201511170000Z"
|
||||
ORGANIZATION "Eltex Co"
|
||||
CONTACT-INFO "eltex.nsk.ru"
|
||||
DESCRIPTION "Mib for Eltex MES ethernet switches."
|
||||
REVISION "201511170000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { elHardware 23 }
|
||||
|
||||
Percents ::= INTEGER (0..100)
|
||||
NetNumber ::= OCTET STRING (SIZE(4))
|
||||
VlanPriority ::= INTEGER (0..7)
|
||||
|
||||
-- Some MIB compilers require that the following 7 lines which define the path
|
||||
-- to Elt MIB are commented out:
|
||||
|
||||
-- mib OBJECT IDENTIFIER ::= { mgmt 1 }
|
||||
-- directory OBJECT IDENTIFIER ::= { internet 1 }
|
||||
-- experimental OBJECT IDENTIFIER ::= { internet 3 }
|
||||
-- private OBJECT IDENTIFIER ::= { internet 4 }
|
||||
-- enterprises OBJECT IDENTIFIER ::= { private 1 }
|
||||
|
||||
-- Objects in this MIB are arranged into groups:
|
||||
--01 eltMesMng - Management/Action
|
||||
--02 ...
|
||||
|
||||
-- At the end of the MIB there is a definition of all Eltex-specific traps.
|
||||
|
||||
eltMesNotifications OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION " All the Eltex notifications will reside under this branch
|
||||
as specified in
|
||||
RFC2578 'Structure of Management Information Version 2 (SMIv2)' 8.5"
|
||||
::= { eltMes 0 }
|
||||
|
||||
-- eltMesMng group contains Management Variables for Eltex devices
|
||||
|
||||
eltMesMng OBJECT IDENTIFIER ::= { eltMes 1 }
|
||||
-- see eltMng.mib
|
||||
|
||||
eltMesDevParams OBJECT IDENTIFIER ::= { eltMes 2}
|
||||
-- see eltDevParams.mib
|
||||
|
||||
eltMesCopy OBJECT IDENTIFIER ::= { eltMes 3 }
|
||||
-- see eltCopy.mib
|
||||
|
||||
eltMesIpOspfMtu OBJECT IDENTIFIER ::= { eltMes 4 }
|
||||
-- see eltIpOspfMtu.mib
|
||||
|
||||
eltMesIpBfd OBJECT IDENTIFIER ::= { eltMes 6 }
|
||||
-- see eltIpBfd.mib
|
||||
|
||||
eltMesIpUnnumbered OBJECT IDENTIFIER ::= { eltMes 7 }
|
||||
-- see eltIpUnnumbered.mib
|
||||
|
||||
eltMesDhcp OBJECT IDENTIFIER ::= { eltMes 8 }
|
||||
-- see eltDhcp.mib
|
||||
|
||||
eltMesLinkAgg OBJECT IDENTIFIER ::= { eltMes 9 }
|
||||
-- see eltLinkAgg.mib
|
||||
|
||||
-- eltMesSyslog OBJECT IDENTIFIER ::= { eltMes 10 }
|
||||
-- see eltSyslog.mib
|
||||
|
||||
--eltMesEnv OBJECT IDENTIFIER ::= { eltMes 11 }
|
||||
-- see eltEnv.mib
|
||||
|
||||
eltMesQosTailDropMib OBJECT IDENTIFIER ::= { eltMes 12 }
|
||||
-- see eltQosTailDropMib.mib
|
||||
|
||||
--eltMesL2TunnelConfig ::= { eltMes 13 }
|
||||
-- see ELTEX-L2-TUNNEL-CONFIG-MIB.mib
|
||||
|
||||
eltMesHardwareMib OBJECT IDENTIFIER ::= { eltMes 14 }
|
||||
-- see eltHardware.mib
|
||||
|
||||
eltMesSsh OBJECT IDENTIFIER ::= { eltMes 15 }
|
||||
-- see ELTEX-MES-SSH-MIB.mib
|
||||
|
||||
eltMesSecuritySuiteMIB OBJECT IDENTIFIER ::= { eltMes 19 }
|
||||
-- see ELTEX-MES-SECURITY-SUITE-MIB.mib
|
||||
|
||||
eltMesTuning OBJECT IDENTIFIER ::= { eltMes 29 }
|
||||
-- see eltTuning.mib
|
||||
|
||||
eltMesSwInterfaces OBJECT IDENTIFIER ::= { eltMes 43 }
|
||||
-- see eltInterfaces.mib
|
||||
|
||||
eltMesIpMulticast OBJECT IDENTIFIER ::= { eltMes 46 }
|
||||
--see eltBrgMulticast.mib
|
||||
|
||||
eltMesPhdTransceiver OBJECT IDENTIFIER ::= { eltMes 53 }
|
||||
--see ELTEX-PHYSICAL-DESCRIPTION-MIB.mib
|
||||
|
||||
eltMesMacMulticast OBJECT IDENTIFIER ::= { eltMes 55 }
|
||||
--see eltBrgMulticast.mib
|
||||
|
||||
eltMesStormCtrl OBJECT IDENTIFIER ::= { eltMes 77 }
|
||||
--see elteltStormCtrl.mib
|
||||
|
||||
eltMesAAA OBJECT IDENTIFIER ::= { eltMes 79 }
|
||||
--see eltAAA.mib
|
||||
|
||||
eltMesRadius OBJECT IDENTIFIER ::= { eltMes 80 }
|
||||
--see eltAAA.mib
|
||||
|
||||
eltMesTacacs OBJECT IDENTIFIER ::= { eltMes 81 }
|
||||
--see eltAAA.mib
|
||||
|
||||
eltMesSmon OBJECT IDENTIFIER ::= { eltMes 84 }
|
||||
--see eltSmon.mib
|
||||
|
||||
eltMesQosCliMib OBJECT IDENTIFIER ::= { eltMes 88 }
|
||||
--see eltQosclimib.mib
|
||||
|
||||
eltMesPhy OBJECT IDENTIFIER ::= { eltMes 90 }
|
||||
-- see eltPhy.mib
|
||||
|
||||
eltMesIpSpec OBJECT IDENTIFIER ::= { eltMes 91 }
|
||||
-- see eltip.mib
|
||||
|
||||
eltMesDot1x OBJECT IDENTIFIER ::= { eltMes 95 }
|
||||
-- see eltdot1x.mib
|
||||
|
||||
eltMesBridgeSecurity OBJECT IDENTIFIER ::= { eltMes 112}
|
||||
--see eltBridgeSecurity.mib
|
||||
|
||||
eltMesEndOfMibGroup OBJECT IDENTIFIER ::= { eltMes 1000 }
|
||||
-- see ELTEX-ENDOFMIB-MIB.MIB
|
||||
|
||||
|
||||
|
||||
END
|
||||
|
136
MIBS/eltexmes23xx/ELTEX-MES-HWENVIROMENT-MIB
Normal file
136
MIBS/eltexmes23xx/ELTEX-MES-HWENVIROMENT-MIB
Normal file
@ -0,0 +1,136 @@
|
||||
ELTEX-MES-HWENVIROMENT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: Eltex MES Hardware enviroment definition
|
||||
-- Version: 1.3
|
||||
-- Date: 27-Jul-2018
|
||||
|
||||
IMPORTS
|
||||
eltMes FROM ELTEX-MES
|
||||
OBJECT-TYPE FROM SNMPv2-SMI
|
||||
RlEnvMonState, rlEnvMonFanStatusEntry FROM RADLAN-HWENVIROMENT;
|
||||
|
||||
eltMesEnv MODULE-IDENTITY
|
||||
LAST-UPDATED "201807270000Z"
|
||||
ORGANIZATION "Eltex Enterprise Co, Ltd."
|
||||
CONTACT-INFO "www.eltex.nsk.ru"
|
||||
DESCRIPTION
|
||||
"This private MIB module contains Eltex's hardware enviroment definition."
|
||||
REVISION "201807270000Z"
|
||||
DESCRIPTION
|
||||
"Added eltEnvResetButtonMode scalar."
|
||||
REVISION "201710110000Z"
|
||||
DESCRIPTION
|
||||
"Added Eltex's hardware enviroment definition."
|
||||
REVISION "201506110000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { eltMes 11 }
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
-- eltEnvMonBatteryStatusTable
|
||||
--------------------------------------------------------------------------------
|
||||
|
||||
eltEnvMonBatteryStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EltEnvMonBatteryStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of battery status maintained by the environmental monitor
|
||||
card."
|
||||
::= { eltMesEnv 1 }
|
||||
|
||||
eltEnvMonBatteryStatusEntry OBJECT-TYPE
|
||||
SYNTAX EltEnvMonBatteryStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the battery status table, representing the status of
|
||||
the associated battery maintained by the environmental monitor."
|
||||
INDEX { eltEnvMonBatteryStatusIndex }
|
||||
::= { eltEnvMonBatteryStatusTable 1 }
|
||||
|
||||
EltEnvMonBatteryStatusEntry ::= SEQUENCE {
|
||||
eltEnvMonBatteryStatusIndex INTEGER,
|
||||
eltEnvMonBatteryState RlEnvMonState,
|
||||
eltEnvMonBatteryStatusCharge INTEGER
|
||||
}
|
||||
|
||||
eltEnvMonBatteryStatusIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the battery being instrumented. This index is for SNMP
|
||||
purposes only, and has no intrinsic meaning."
|
||||
::= { eltEnvMonBatteryStatusEntry 1 }
|
||||
|
||||
eltEnvMonBatteryState OBJECT-TYPE
|
||||
SYNTAX RlEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The mandatory state of the battery being instrumented."
|
||||
::= { eltEnvMonBatteryStatusEntry 2 }
|
||||
|
||||
eltEnvMonBatteryStatusCharge OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..100 | 255)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Remaining percentage of battery charge. Value of 255 means that this
|
||||
parameter is undefined due to battery not supporting this feature or
|
||||
because it cannot be obtained in current state."
|
||||
::= { eltEnvMonBatteryStatusEntry 3 }
|
||||
|
||||
--
|
||||
-- eltEnvResetButtonMode
|
||||
--
|
||||
|
||||
eltEnvResetButtonMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(0),
|
||||
disable(1),
|
||||
reset-only(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Mode of reset button: 0 - Enable, 1 - disable, 2 - reset-only mode"
|
||||
DEFVAL { enable }
|
||||
::= { eltMesEnv 2 }
|
||||
|
||||
|
||||
--
|
||||
-- eltEnvMonFanStatusTable
|
||||
--
|
||||
|
||||
eltEnvMonFanStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EltEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of fan status maintained by the environmental monitor"
|
||||
::= { eltMesEnv 3 }
|
||||
|
||||
eltEnvMonFanStatusEntry OBJECT-TYPE
|
||||
SYNTAX EltEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table augments existing RADLAN table rlEnvMonFanStatusTable"
|
||||
AUGMENTS { rlEnvMonFanStatusEntry }
|
||||
::= { eltEnvMonFanStatusTable 1 }
|
||||
|
||||
EltEnvMonFanStatusEntry ::= SEQUENCE {
|
||||
eltEnvMonFanSpeed INTEGER
|
||||
}
|
||||
|
||||
eltEnvMonFanSpeed OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This parameter represents the speed of the fan in RPM"
|
||||
::= { eltEnvMonFanStatusEntry 1 }
|
||||
|
||||
END
|
564
MIBS/eltexmes23xx/ELTEX-MES-PHYSICAL-DESCRIPTION-MIB
Normal file
564
MIBS/eltexmes23xx/ELTEX-MES-PHYSICAL-DESCRIPTION-MIB
Normal file
@ -0,0 +1,564 @@
|
||||
ELTEX-MES-PHYSICAL-DESCRIPTION-MIB DEFINITIONS ::= BEGIN
|
||||
-- Version: 2.3
|
||||
-- Date: 04-Aug-2021
|
||||
|
||||
IMPORTS
|
||||
OBJECT-TYPE, MODULE-IDENTITY, TimeTicks,
|
||||
NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI
|
||||
DisplayString, PhysAddress, RowStatus, TruthValue FROM SNMPv2-TC
|
||||
JackType FROM MAU-MIB
|
||||
InterfaceIndexOrZero,ifIndex,InterfaceIndex FROM IF-MIB
|
||||
eltMes FROM ELTEX-MES
|
||||
rlPhdUnitGenParamEntry, rlCascadeEntry, rlCascadeAdminEntry
|
||||
FROM RADLAN-Physicaldescription-MIB
|
||||
;
|
||||
|
||||
eltMesPhysicalDescription MODULE-IDENTITY
|
||||
LAST-UPDATED "202108040000Z"
|
||||
ORGANIZATION "Eltex Ltd."
|
||||
CONTACT-INFO
|
||||
"eltex.nsk.ru"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for physical
|
||||
device configuration and information."
|
||||
|
||||
REVISION "202108040000Z"
|
||||
DESCRIPTION
|
||||
"Added eltCascadeAdminTable, added field eltCascadeFecOperMode
|
||||
to eltCascadeEntry."
|
||||
|
||||
REVISION "201804240000Z"
|
||||
DESCRIPTION
|
||||
"Added eltPhdTransceiverThresholdTable."
|
||||
|
||||
REVISION "201711110000Z"
|
||||
DESCRIPTION
|
||||
"Added fields eltPhdTransceiverInfoPartNumber and
|
||||
eltPhdTransceiverInfoVendorRev to eltPhdTransceiverInfoTable"
|
||||
|
||||
REVISION "201509140000Z"
|
||||
DESCRIPTION
|
||||
"Added eltPhdUnitGenParamTable."
|
||||
|
||||
REVISION "201303210000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { eltMes 53 }
|
||||
|
||||
eltMesPhdTransceiver OBJECT IDENTIFIER ::= { eltMesPhysicalDescription 1 }
|
||||
|
||||
eltPhdTransceiverInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EltPhdTransceiverInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table show the information of transceiver on interface."
|
||||
::= { eltMesPhdTransceiver 1 }
|
||||
|
||||
eltPhdTransceiverInfoEntry OBJECT-TYPE
|
||||
SYNTAX EltPhdTransceiverInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry of the eltPhdTransceiverInfoTable."
|
||||
INDEX { ifIndex }
|
||||
::= { eltPhdTransceiverInfoTable 1 }
|
||||
|
||||
EltPhdTransceiverInfoEntry ::=
|
||||
SEQUENCE {
|
||||
eltPhdTransceiverInfoConnectorType INTEGER,
|
||||
eltPhdTransceiverInfoType INTEGER,
|
||||
eltPhdTransceiverInfoComplianceCode OCTET STRING,
|
||||
eltPhdTransceiverInfoWaveLength Integer32,
|
||||
eltPhdTransceiverInfoVendorName OCTET STRING,
|
||||
eltPhdTransceiverInfoSerialNumber OCTET STRING,
|
||||
eltPhdTransceiverInfoFiberDiameterType INTEGER,
|
||||
eltPhdTransceiverInfoTransferDistance Integer32,
|
||||
eltPhdTransceiverInfoDiagnostic TruthValue,
|
||||
eltPhdTransceiverInfoPartNumber OCTET STRING,
|
||||
eltPhdTransceiverInfoVendorRev OCTET STRING
|
||||
}
|
||||
|
||||
eltPhdTransceiverInfoConnectorType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
unknown(0),
|
||||
sc(1),
|
||||
fibre-ch-st1(2),
|
||||
fibre-ch-st2(3),
|
||||
bnc-tnc(4),
|
||||
fibre-ch-coaxial-headers(5),
|
||||
fibrejack(6),
|
||||
lc(7),
|
||||
mt-rj(8),
|
||||
mu(9),
|
||||
sg(10),
|
||||
optical-pigtail(11),
|
||||
mpo-parallel-optic(12),
|
||||
hssdc-ii(32),
|
||||
copper-pigtail(33),
|
||||
rj45(34),
|
||||
no-separable-connector(35),
|
||||
unallocated(127),
|
||||
vendorspec(255)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Connector type of the interface."
|
||||
::= { eltPhdTransceiverInfoEntry 1 }
|
||||
|
||||
eltPhdTransceiverInfoType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
unknown(0),
|
||||
gbic(1),
|
||||
sff(2),
|
||||
sfp-sfpplus(3),
|
||||
xbi-300-pin(4),
|
||||
xenpak(5),
|
||||
xfp(6),
|
||||
xff(7),
|
||||
xfp-e(8),
|
||||
xpak(9),
|
||||
x2(10),
|
||||
dwdm-sfp(11),
|
||||
qsfp(12),
|
||||
qsfpplus(13),
|
||||
reserved(127),
|
||||
vendorspec(255)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of the interface, such as SFP/XFP/GBIC."
|
||||
::= { eltPhdTransceiverInfoEntry 2 }
|
||||
|
||||
eltPhdTransceiverInfoComplianceCode OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Compliance code read from the transceiver."
|
||||
::= { eltPhdTransceiverInfoEntry 3 }
|
||||
|
||||
eltPhdTransceiverInfoWaveLength OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Wave length of the interface, measured in nanometer."
|
||||
::= { eltPhdTransceiverInfoEntry 4 }
|
||||
|
||||
eltPhdTransceiverInfoVendorName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Vendor name of the interface."
|
||||
::= { eltPhdTransceiverInfoEntry 5 }
|
||||
|
||||
eltPhdTransceiverInfoSerialNumber OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Serial number of the interface."
|
||||
::= { eltPhdTransceiverInfoEntry 6 }
|
||||
|
||||
eltPhdTransceiverInfoFiberDiameterType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
fiber9(1),
|
||||
fiber50(2),
|
||||
fiber625(3),
|
||||
copper(4),
|
||||
unknown(65535)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The diameter of the fiber, measured in micron.
|
||||
fiber9 - 9 micron multi-mode fiber
|
||||
fiber50 - 50 micron multi-mode fiber
|
||||
fiber625 - 62.5 micron multi-mode fiber
|
||||
copper - copper cable."
|
||||
::= { eltPhdTransceiverInfoEntry 7 }
|
||||
|
||||
eltPhdTransceiverInfoTransferDistance OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximal distance which the interface could transmit,
|
||||
measured in meter."
|
||||
::= { eltPhdTransceiverInfoEntry 8 }
|
||||
|
||||
eltPhdTransceiverInfoDiagnostic OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicating whether the digital diagnostic monitoring function is supported or not."
|
||||
::= { eltPhdTransceiverInfoEntry 9 }
|
||||
|
||||
eltPhdTransceiverInfoPartNumber OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Part number provided by SFP vendor."
|
||||
::= { eltPhdTransceiverInfoEntry 10 }
|
||||
|
||||
eltPhdTransceiverInfoVendorRev OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Revision level for part number provided by vendor."
|
||||
::= { eltPhdTransceiverInfoEntry 11 }
|
||||
|
||||
--
|
||||
-- eltPhdUnitGenParamTable
|
||||
--
|
||||
|
||||
eltPhdUnitGenParamTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EltPhdUnitGenParamEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"For each module (board) there is an entry describing it in this
|
||||
module"
|
||||
::= { eltMesPhysicalDescription 2 }
|
||||
|
||||
eltPhdUnitGenParamEntry OBJECT-TYPE
|
||||
SYNTAX EltPhdUnitGenParamEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table augments existing RADLAN table rlPhdUnitGenParamTable"
|
||||
AUGMENTS { rlPhdUnitGenParamEntry }
|
||||
::= { eltPhdUnitGenParamTable 1 }
|
||||
|
||||
EltPhdUnitGenParamEntry ::= SEQUENCE {
|
||||
eltPhdUnitGenParamCommitHash DisplayString,
|
||||
eltPhdUnitGenParamBuildTag DisplayString,
|
||||
eltPhdUnitGenParamBuildNumber DisplayString
|
||||
}
|
||||
|
||||
eltPhdUnitGenParamCommitHash OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Hash of current commit."
|
||||
::= { eltPhdUnitGenParamEntry 1 }
|
||||
|
||||
eltPhdUnitGenParamBuildTag OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Build branch."
|
||||
::= { eltPhdUnitGenParamEntry 2 }
|
||||
|
||||
eltPhdUnitGenParamBuildNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Build describe number."
|
||||
::= { eltPhdUnitGenParamEntry 3 }
|
||||
|
||||
--
|
||||
-- eltCascadeTable
|
||||
--
|
||||
|
||||
eltCascadeTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EltCascadeEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table augments existing RADLAN table rlCascadeTable."
|
||||
::= { eltMesPhysicalDescription 3 }
|
||||
|
||||
eltCascadeEntry OBJECT-TYPE
|
||||
SYNTAX EltCascadeEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry of this table specifies a cascaded link information in a unit"
|
||||
AUGMENTS { rlCascadeEntry }
|
||||
::= { eltCascadeTable 1 }
|
||||
|
||||
EltCascadeEntry ::= SEQUENCE {
|
||||
eltCascadeLastChange TimeTicks,
|
||||
eltCascadeOperStatus INTEGER,
|
||||
eltCascadeDuplexOperMode INTEGER,
|
||||
eltCascadeOperSpeedDuplexAutoNegotiation INTEGER,
|
||||
eltCascadeOperMdix INTEGER,
|
||||
eltCascadeTransceiverType INTEGER,
|
||||
eltCascadeIfType INTEGER,
|
||||
eltCascadeFecOperMode INTEGER
|
||||
}
|
||||
|
||||
eltCascadeLastChange OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of sysUpTime at the time the cascade interface
|
||||
entered its current operational state."
|
||||
::= { eltCascadeEntry 1 }
|
||||
|
||||
eltCascadeOperStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
up(1),
|
||||
down(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the state of this interface."
|
||||
::= { eltCascadeEntry 2 }
|
||||
|
||||
eltCascadeDuplexOperMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
half(1),
|
||||
full(2),
|
||||
hybrid(3),
|
||||
unknown(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates whether this interface operates in half
|
||||
duplex or full duplex mode."
|
||||
::= { eltCascadeEntry 3 }
|
||||
|
||||
eltCascadeOperSpeedDuplexAutoNegotiation OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled(1),
|
||||
disabled(2),
|
||||
hybrid(3),
|
||||
unknown(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If enabled the speed and duplex are determined by the device through
|
||||
the autonegotiation process."
|
||||
::= { eltCascadeEntry 4 }
|
||||
|
||||
eltCascadeOperMdix OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
cross(2),
|
||||
auto(3),
|
||||
unknown(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"cross - The interface is in crossover mode.
|
||||
normal - The interface is not in crossover mode.
|
||||
unknown - Only for port that its operative status is not present
|
||||
or down."
|
||||
::= { eltCascadeEntry 5 }
|
||||
|
||||
eltCascadeTransceiverType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
regular(1),
|
||||
fiberOptics(2),
|
||||
comboRegular(3),
|
||||
comboFiberOptics(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the transceiver type of this interface."
|
||||
::= { eltCascadeEntry 6 }
|
||||
|
||||
eltCascadeIfType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
eth10M(1),
|
||||
eth100M(2),
|
||||
eth1000M(3),
|
||||
eth10G(4),
|
||||
eth20G(5),
|
||||
eth40G(6),
|
||||
eth100G(7),
|
||||
unknown(8)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable specifies the type of interface."
|
||||
::= { eltCascadeEntry 7 }
|
||||
|
||||
eltCascadeFecOperMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(0),
|
||||
auto(1),
|
||||
cl74(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the actual Forward Error Correction (FEC) mode
|
||||
that currently in use on the port."
|
||||
::= { eltCascadeEntry 8 }
|
||||
|
||||
--
|
||||
-- eltPhdTransceiverThresholdTable
|
||||
--
|
||||
|
||||
eltPhdTransceiverThresholdTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EltPhdTransceiverThresholdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains the threshold information of transceiver."
|
||||
::= { eltMesPhdTransceiver 2 }
|
||||
|
||||
eltPhdTransceiverThresholdEntry OBJECT-TYPE
|
||||
SYNTAX EltPhdTransceiverThresholdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry of the eltPhdTransceiverThresholdTable."
|
||||
INDEX { ifIndex, eltPhdTransceiverThresholdType }
|
||||
::= { eltPhdTransceiverThresholdTable 1 }
|
||||
|
||||
EltPhdTransceiverThresholdEntry ::=
|
||||
SEQUENCE {
|
||||
eltPhdTransceiverThresholdType INTEGER,
|
||||
eltPhdTransceiverThresholdAction INTEGER,
|
||||
eltPhdTransceiverThresholdHighAlarm INTEGER,
|
||||
eltPhdTransceiverThresholdHighWarning INTEGER,
|
||||
eltPhdTransceiverThresholdLowWarning INTEGER,
|
||||
eltPhdTransceiverThresholdLowAlarm INTEGER
|
||||
}
|
||||
|
||||
eltPhdTransceiverThresholdType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
temperature(0),
|
||||
supply(1),
|
||||
txBias(2),
|
||||
txOutput(3),
|
||||
rxOpticalPower(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A value indicating the threshold to configure.
|
||||
temperature - degree (Celsius) -127-127, voltage - microVolt 0-6550000,
|
||||
current - microAmper 0-131000, output power or input power - microWatt 0-6553"
|
||||
::= { eltPhdTransceiverThresholdEntry 1 }
|
||||
|
||||
eltPhdTransceiverThresholdAction OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(0),
|
||||
log(1),
|
||||
send-trap(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"What action to perform when value is bad."
|
||||
::= { eltPhdTransceiverThresholdEntry 2 }
|
||||
|
||||
eltPhdTransceiverThresholdHighAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See eltPhdTransceiverThresholdType for details"
|
||||
::= { eltPhdTransceiverThresholdEntry 3 }
|
||||
|
||||
eltPhdTransceiverThresholdHighWarning OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See eltPhdTransceiverThresholdType for details"
|
||||
::= { eltPhdTransceiverThresholdEntry 4 }
|
||||
|
||||
eltPhdTransceiverThresholdLowWarning OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See eltPhdTransceiverThresholdType for details"
|
||||
::= { eltPhdTransceiverThresholdEntry 5 }
|
||||
|
||||
eltPhdTransceiverThresholdLowAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See eltPhdTransceiverThresholdType for details"
|
||||
::= { eltPhdTransceiverThresholdEntry 6 }
|
||||
|
||||
--
|
||||
-- eltMesPhdNsf
|
||||
--
|
||||
|
||||
eltMesPhdNsf OBJECT IDENTIFIER ::= { eltMesPhysicalDescription 4 }
|
||||
|
||||
eltPhdNsfEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable Non-Stop Forwarding during the stack master switchover."
|
||||
DEFVAL { false }
|
||||
::= { eltMesPhdNsf 1 }
|
||||
|
||||
eltPhdNsfTime OBJECT-TYPE
|
||||
SYNTAX INTEGER (60..600)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Set the time period in which protocols wait for the new master to complete initialization.
|
||||
The port states set by the former master is preserved during this time."
|
||||
DEFVAL {120}
|
||||
::= { eltMesPhdNsf 2 }
|
||||
|
||||
--
|
||||
-- eltCascadeAdminTable
|
||||
--
|
||||
|
||||
eltCascadeAdminTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EltCascadeAdminEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table augments existing RADLAN table rlCascadeAdminTable."
|
||||
::= { eltMesPhysicalDescription 6 }
|
||||
|
||||
eltCascadeAdminEntry OBJECT-TYPE
|
||||
SYNTAX EltCascadeAdminEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry of this table specifies a cascaded information in a unit after reset"
|
||||
AUGMENTS { rlCascadeAdminEntry }
|
||||
::= { eltCascadeAdminTable 1 }
|
||||
|
||||
EltCascadeAdminEntry ::= SEQUENCE {
|
||||
eltCascadeAdminFec INTEGER
|
||||
}
|
||||
|
||||
eltCascadeAdminFec OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(0),
|
||||
auto(1),
|
||||
cl74(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable controls the Forward Error Correction (FEC) mode on the port."
|
||||
::= { eltCascadeAdminEntry 1 }
|
||||
|
||||
END
|
4187
MIBS/eltexmes23xx/ELTEX-SMI-ACTUAL
Normal file
4187
MIBS/eltexmes23xx/ELTEX-SMI-ACTUAL
Normal file
File diff suppressed because it is too large
Load Diff
542
MIBS/eltexmes23xx/MARVELL-POE-MIB
Normal file
542
MIBS/eltexmes23xx/MARVELL-POE-MIB
Normal file
@ -0,0 +1,542 @@
|
||||
MARVELL-POE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: Marvell LOCALIZATION ROS
|
||||
-- This Private MIB is enhancement for rfc3621.txt - Power Ethernet Mib
|
||||
-- Version: 7.50
|
||||
-- Date: 28 Nov 2005
|
||||
|
||||
IMPORTS
|
||||
rnd FROM RADLAN-MIB
|
||||
DisplayString, TruthValue FROM SNMPv2-TC
|
||||
InterfaceIndex FROM IF-MIB
|
||||
OBJECT-TYPE, MODULE-IDENTITY, Unsigned32 FROM SNMPv2-SMI;
|
||||
|
||||
|
||||
rlPoe MODULE-IDENTITY
|
||||
LAST-UPDATED "200911260000Z"
|
||||
ORGANIZATION "Marvell."
|
||||
CONTACT-INFO
|
||||
"Marvell.com"
|
||||
DESCRIPTION
|
||||
"Add a new field in the PoE MIB to indicate Max power allocation allowed"
|
||||
REVISION "201006020000Z"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for Power Over Ethernet."
|
||||
REVISION "200911260000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { rnd 108 }
|
||||
|
||||
RlPoeType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION "PoE types:
|
||||
1 - none: no PoE, unknown type;
|
||||
2 - PoE: Standard AF PoE
|
||||
3 - PoE Plus: Standard AT PoE
|
||||
4 - 60 W: 60W poe port "
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
poe(2),
|
||||
poeplus(3),
|
||||
poe60w(4)
|
||||
}
|
||||
|
||||
rlPethPsePortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPethPsePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table listing additional information for Power Over Ethernet ports."
|
||||
::= {rlPoe 1 }
|
||||
|
||||
rlPethPsePortEntry OBJECT-TYPE
|
||||
SYNTAX RlPethPsePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rlPethPsePortTable."
|
||||
INDEX { rlPethPsePortGroupIndex , rlPethPsePortIndex }
|
||||
::= {rlPethPsePortTable 1 }
|
||||
|
||||
RlPethPsePortEntry ::= SEQUENCE {
|
||||
rlPethPsePortGroupIndex INTEGER,
|
||||
rlPethPsePortIndex INTEGER,
|
||||
rlPethPsePortOutputVoltage INTEGER,
|
||||
rlPethPsePortOutputCurrent INTEGER,
|
||||
rlPethPsePortOutputPower INTEGER,
|
||||
rlPethPsePortPowerLimit INTEGER,
|
||||
rlPethPsePortStatus INTEGER,
|
||||
rlPethPsePortStatusDescription DisplayString,
|
||||
rlPethPsePortOperPowerLimit INTEGER,
|
||||
rlPethPsePortTimeRangeName DisplayString,
|
||||
rlPethPsePortOperStatus TruthValue,
|
||||
rlPethPsePortMaxPowerAllocAllowed INTEGER,
|
||||
rlPethPsePortSupportPoeType RlPoeType,
|
||||
rlPethPsePortLinkPartnerPoeType RlPoeType,
|
||||
rlPethPsePortFourPairForced INTEGER,
|
||||
rlPethPsePortFourPairEnabled INTEGER,
|
||||
rlPethPsePortNegotiationAllocatedPower INTEGER,
|
||||
rlPethPsePortNegotiationProtocolOwner INTEGER
|
||||
}
|
||||
|
||||
rlPethPsePortGroupIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the group
|
||||
containing the port to which a power Ethernet PSE is
|
||||
connected. Group means box in the stack, module in a
|
||||
rack and the value 1 MUST be used for non-modular devices.
|
||||
Furthermore, the same value MUST be used in this variable,
|
||||
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
|
||||
to refer to a given box in a stack or module in the rack."
|
||||
::= { rlPethPsePortEntry 1 }
|
||||
|
||||
rlPethPsePortIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the power Ethernet PSE
|
||||
port within group pethPsePortGroupIndex to which the
|
||||
power Ethernet PSE entry is connected."
|
||||
::= { rlPethPsePortEntry 2 }
|
||||
|
||||
rlPethPsePortOutputVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 3 }
|
||||
|
||||
rlPethPsePortOutputCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the output current level in milli amper from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 4 }
|
||||
|
||||
rlPethPsePortOutputPower OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the output power level in milli watts from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 5 }
|
||||
|
||||
rlPethPsePortPowerLimit OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 6 }
|
||||
|
||||
rlPethPsePortStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the hardware status of rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 7 }
|
||||
|
||||
rlPethPsePortStatusDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..80))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the description of the hardware status of rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 8 }
|
||||
|
||||
rlPethPsePortOperPowerLimit OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 9 }
|
||||
|
||||
rlPethPsePortTimeRangeName OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..32))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable is used to bind PoE port to time range."
|
||||
::= { rlPethPsePortEntry 10 }
|
||||
|
||||
rlPethPsePortOperStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status."
|
||||
::= { rlPethPsePortEntry 11 }
|
||||
|
||||
rlPethPsePortMaxPowerAllocAllowed OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 12 }
|
||||
|
||||
rlPethPsePortSupportPoeType OBJECT-TYPE
|
||||
SYNTAX RlPoeType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the supported type of the PoE port"
|
||||
::= { rlPethPsePortEntry 13 }
|
||||
|
||||
rlPethPsePortLinkPartnerPoeType OBJECT-TYPE
|
||||
SYNTAX RlPoeType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the link partner PoE type."
|
||||
::= { rlPethPsePortEntry 14 }
|
||||
|
||||
rlPethPsePortFourPairForced OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
forcedEnable(0),
|
||||
forcedDisable(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable enabled the spare pair ALT_B in 60W port to force 4 pair enable."
|
||||
::= { rlPethPsePortEntry 15 }
|
||||
|
||||
rlPethPsePortFourPairEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fourPairEnable(1),
|
||||
fourPairDisable(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates that spare pair ALT_B is enable."
|
||||
::= { rlPethPsePortEntry 16 }
|
||||
|
||||
rlPethPsePortNegotiationAllocatedPower OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the power allocation in milli watts from power negotiation"
|
||||
::= { rlPethPsePortEntry 17 }
|
||||
|
||||
rlPethPsePortNegotiationProtocolOwner OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
protocolOwnerNone(0),
|
||||
protocolOwnerCDP(1),
|
||||
protocolOwnerLLDP(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the protocol owner on power management negotiation protocol"
|
||||
::= { rlPethPsePortEntry 18 }
|
||||
|
||||
rlPethMainPseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPethMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table listing additional read - only information for Power Over Ethernet."
|
||||
::= {rlPoe 2 }
|
||||
|
||||
rlPethMainPseEntry OBJECT-TYPE
|
||||
SYNTAX RlPethMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rlPethMainPseTable."
|
||||
INDEX { rlPethMainPseGroupIndex }
|
||||
::= {rlPethMainPseTable 1 }
|
||||
|
||||
RlPethMainPseEntry ::= SEQUENCE {
|
||||
rlPethMainPseGroupIndex INTEGER,
|
||||
rlPethMainPseSwVersion DisplayString,
|
||||
rlPethMainPseHwVersion DisplayString,
|
||||
rlPethMainPseHwType INTEGER,
|
||||
rlPethMainPsePowerGuardBand INTEGER
|
||||
|
||||
}
|
||||
|
||||
rlPethMainPseGroupIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the group
|
||||
containing the port to which a power Ethernet PSE is
|
||||
connected. Group means box in the stack, module in a
|
||||
rack and the value 1 MUST be used for non-modular devices.
|
||||
Furthermore, the same value MUST be used in this variable,
|
||||
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
|
||||
to refer to a given box in a stack or module in the rack."
|
||||
::= { rlPethMainPseEntry 1 }
|
||||
|
||||
rlPethMainPseSwVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..20))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the MCU SW version."
|
||||
::= { rlPethMainPseEntry 2 }
|
||||
|
||||
rlPethMainPseHwVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..20))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the MCU HW version."
|
||||
::= { rlPethMainPseEntry 3 }
|
||||
|
||||
rlPethMainPseHwType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enhanced(1),
|
||||
plus(2),
|
||||
auto(3),
|
||||
nonPoe(4),
|
||||
enhancedPlus(5),
|
||||
poe60w(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the MCU HW type (enhanced, plus, none)."
|
||||
::= { rlPethMainPseEntry 4 }
|
||||
|
||||
rlPethMainPsePowerGuardBand OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the guard band in [W] for not connecting
|
||||
additional ports."
|
||||
::= { rlPethMainPseEntry 5 }
|
||||
|
||||
rlPethPowerPseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPethPowerPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table listing additional read-write information for Power Over Ethernet - PSE side."
|
||||
::= {rlPoe 3 }
|
||||
|
||||
rlPethPowerPseEntry OBJECT-TYPE
|
||||
SYNTAX RlPethPowerPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rlPethPowerPseTable."
|
||||
INDEX { rlPethPowerPseGroupIndex }
|
||||
::= {rlPethPowerPseTable 1 }
|
||||
|
||||
RlPethPowerPseEntry ::= SEQUENCE {
|
||||
rlPethPowerPseGroupIndex INTEGER,
|
||||
rlPethPowerPsePower INTEGER,
|
||||
rlPethPowerPseRpsPower INTEGER,
|
||||
rlPethPowerPsePowerManagementMode INTEGER,
|
||||
rlPethPowerPsedisconnectMethod INTEGER,
|
||||
rlPethPowerPseTemperatureSensor INTEGER,
|
||||
rlPethPowerPseInrushTestEnabled INTEGER,
|
||||
rlPethPowerPseLegacyDisabled INTEGER
|
||||
}
|
||||
|
||||
rlPethPowerPseGroupIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..8)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the group
|
||||
containing the port to which a power Ethernet PSE is
|
||||
connected. Group means box in the stack, module in a
|
||||
rack and the value 1 MUST be used for non-modular devices.
|
||||
Furthermore, the same value MUST be used in this variable,
|
||||
PethPowerPseGroupIndex, and pethNotificationControlGroupIndex
|
||||
to refer to a given box in a stack or module in the rack."
|
||||
::= { rlPethPowerPseEntry 1 }
|
||||
|
||||
|
||||
-- depricated
|
||||
rlPethPowerPsePower OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
ps1(1),
|
||||
ps2(2),
|
||||
ps3(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the maximum power in [W] supplied by PSE."
|
||||
::= { rlPethPowerPseEntry 2 }
|
||||
|
||||
-- depricated
|
||||
rlPethPowerPseRpsPower OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
rps1(1),
|
||||
rps2(2),
|
||||
rps3(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the maximum power in [W] supplied by PSE + RPS."
|
||||
::= { rlPethPowerPseEntry 3 }
|
||||
|
||||
rlPethPowerPsePowerManagementMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
portlimit(0),
|
||||
classlimit(5),
|
||||
maxlimit(6)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies power management mode."
|
||||
::= { rlPethPowerPseEntry 4 }
|
||||
|
||||
rlPethPowerPsedisconnectMethod OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
lowestpriority(0),
|
||||
nextport(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies disconnect method. "
|
||||
::= { rlPethPowerPseEntry 5 }
|
||||
|
||||
rlPethPowerPseTemperatureSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER (-200..200)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the pd temperature sensor. "
|
||||
::= { rlPethPowerPseEntry 6 }
|
||||
|
||||
rlPethPowerPseInrushTestEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled(0),
|
||||
disabled(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies if HW inrush test will be disabled.
|
||||
by default HW inrush test is enabled."
|
||||
::= { rlPethPowerPseEntry 7 }
|
||||
|
||||
rlPethPowerPseLegacyDisabled OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled(0),
|
||||
disabled(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies poe Legacy global configuration mode"
|
||||
::= { rlPethPowerPseEntry 8 }
|
||||
|
||||
|
||||
--rlPethPdPortTable
|
||||
|
||||
rlPethPdPortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPethPdPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table listing additional read-write information for Power Over Ethernet - PD side."
|
||||
::= {rlPoe 4 }
|
||||
|
||||
rlPethPdPortEntry OBJECT-TYPE
|
||||
SYNTAX RlPethPdPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rlPethPdPortTable."
|
||||
INDEX { rlPethPdPortIndex }
|
||||
::= {rlPethPdPortTable 1}
|
||||
|
||||
RlPethPdPortEntry ::= SEQUENCE {
|
||||
rlPethPdPortIndex InterfaceIndex,
|
||||
rlPethPdPortSupportPoeType RlPoeType,
|
||||
rlPethPdPortOperPoeType RlPoeType,
|
||||
rlPethPdPortPowerRequest Unsigned32,
|
||||
rlPethPdPortPowerAvailable Unsigned32,
|
||||
rlPethPdPortForcedMode RlPoeType,
|
||||
rlPethPdPortNegotiationProtocolOwner INTEGER
|
||||
}
|
||||
|
||||
rlPethPdPortIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the power Ethernet PD
|
||||
port within group rlPethPdPortGroupIndex to which the
|
||||
power Ethernet PSE entry is connected."
|
||||
::= { rlPethPdPortEntry 1 }
|
||||
|
||||
rlPethPdPortSupportPoeType OBJECT-TYPE
|
||||
SYNTAX RlPoeType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the PoE type of the PD port (AF/AT/60W)"
|
||||
::= { rlPethPdPortEntry 2 }
|
||||
|
||||
rlPethPdPortOperPoeType OBJECT-TYPE
|
||||
SYNTAX RlPoeType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the operational PoE status of the PD port"
|
||||
::= { rlPethPdPortEntry 3 }
|
||||
|
||||
rlPethPdPortPowerRequest OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the requested power the PD port request from the PSE in mili-Watts"
|
||||
::= { rlPethPdPortEntry 4 }
|
||||
|
||||
rlPethPdPortPowerAvailable OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the available power the PSE port offers to the PD port in mili-Watts"
|
||||
::= { rlPethPdPortEntry 5 }
|
||||
|
||||
rlPethPdPortForcedMode OBJECT-TYPE
|
||||
SYNTAX RlPoeType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the powered PD port forced mode"
|
||||
::= { rlPethPdPortEntry 6 }
|
||||
|
||||
rlPethPdPortNegotiationProtocolOwner OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
protocolOwnerNone(0),
|
||||
protocolOwnerCDP(1),
|
||||
protocolOwnerLLDP(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the protocol owner on power management negotiation protocol"
|
||||
::= { rlPethPdPortEntry 7 }
|
||||
|
||||
END
|
||||
|
795
MIBS/eltexmes23xx/RADLAN-DEVICEPARAMS-MIB
Normal file
795
MIBS/eltexmes23xx/RADLAN-DEVICEPARAMS-MIB
Normal file
@ -0,0 +1,795 @@
|
||||
RADLAN-DEVICEPARAMS-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: RADLAN ROS
|
||||
-- Private DEVICE PARAMETERS MIB
|
||||
-- Version: 7.46
|
||||
-- Date: 15-Jan-2007
|
||||
|
||||
IMPORTS
|
||||
rnd FROM RADLAN-MIB
|
||||
OBJECT-TYPE, MODULE-IDENTITY, IpAddress FROM SNMPv2-SMI
|
||||
TruthValue, DisplayString, PhysAddress FROM SNMPv2-TC;
|
||||
|
||||
rndDeviceParams MODULE-IDENTITY
|
||||
LAST-UPDATED "200701020000Z"
|
||||
ORGANIZATION "Radlan - a MARVELL company.
|
||||
Marvell Semiconductor, Inc."
|
||||
CONTACT-INFO
|
||||
"www.marvell.com"
|
||||
DESCRIPTION
|
||||
"This private MIB module defines general Parameters private MIBs."
|
||||
REVISION "200701020000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { rnd 2 }
|
||||
|
||||
-- rndDeviceParams group contains a number of general variables
|
||||
|
||||
rndBridgeType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
reb(1),
|
||||
ceb(2),
|
||||
ceblb(3),
|
||||
xeb(4),
|
||||
xeb1(5),
|
||||
rebsx(6),
|
||||
rtb(7),
|
||||
ltb(8),
|
||||
tre(9),
|
||||
rtre(10), -- remote TRE
|
||||
xtb(11),
|
||||
ete(12),
|
||||
rete(13), -- remote ETE
|
||||
ielb(30),
|
||||
leb(31),
|
||||
openGate12(32),
|
||||
openGate4(33),
|
||||
ran(34),
|
||||
itlb(35),
|
||||
gatelinx(36),
|
||||
openGate2(37),
|
||||
ogRanTR(38),
|
||||
rdapter(39),
|
||||
ogVan(40),
|
||||
wanGate(41),
|
||||
ogRubE(42),
|
||||
ogRubT(43),
|
||||
wanGateI(44),
|
||||
vGate4(45),
|
||||
lre(46),
|
||||
mrt(47),
|
||||
vGate2(48)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identification of the RND bridge type."
|
||||
::= { rndDeviceParams 1 }
|
||||
|
||||
|
||||
rndInactiveArpTimeOut OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable defines the maximum time period that can pass
|
||||
between ARP requests concerning an entry in the ARP table.
|
||||
After this time period, the entry is deleted from the table."
|
||||
::= { rndDeviceParams 2 }
|
||||
|
||||
-- The following two variables define the format of RND specific
|
||||
-- error messages issued by the RND devices
|
||||
|
||||
rndBridgeAlarm OBJECT IDENTIFIER ::= { rndDeviceParams 3 }
|
||||
|
||||
rndErrorDesc OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual description of the enterprise-specific trap sent
|
||||
to the Network Management Station by the RND managed device."
|
||||
::= { rndBridgeAlarm 1 }
|
||||
|
||||
rndErrorSeverity OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
info(0),
|
||||
warning(1),
|
||||
error(2),
|
||||
fatal-error(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The severity type of the enterprise-specific trap sent to the
|
||||
Network Management Station by the RND managed device."
|
||||
::= { rndBridgeAlarm 2 }
|
||||
|
||||
rndBrgVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The bridge version."
|
||||
::= { rndDeviceParams 4 }
|
||||
|
||||
rndBrgFeatures OBJECT-TYPE
|
||||
SYNTAX OCTET STRING -- SIZE 20
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A bit mask that defines the features supported by a particular configuration
|
||||
of this network element:
|
||||
__________________________________________
|
||||
| Byte 1|Byte 2 |Byte 3 | ....|Byte 20 |
|
||||
|87654321| | 87654321|
|
||||
|________|_______________________________|
|
||||
|
||||
Byte1 :
|
||||
bit1: TX Block mask
|
||||
bit2: Source Routing Encapulation
|
||||
bit3: SNA/SDLC
|
||||
bit4: Frame Relay
|
||||
bit5: SNMP
|
||||
bit6: LAN Manager
|
||||
bit7: High Performance
|
||||
bit8: Translation
|
||||
Byte2 :
|
||||
bit1: DEC Router
|
||||
bit2: IPX Router
|
||||
bit3: IP Router
|
||||
Byte3 :
|
||||
bit1: Dial Up Backup
|
||||
bit2: COD
|
||||
bit3: FACS
|
||||
bit4: Load Balance
|
||||
bit5: Remote Configuration
|
||||
bit6: RIP 2
|
||||
bit7: OSPF
|
||||
bit8: IPX RIP/SAP Filter
|
||||
Byte4 :
|
||||
bit1: BootP Server
|
||||
bit2: BootP Client
|
||||
bit3: Compression
|
||||
bit4: V25.bis
|
||||
bit5: ISDN
|
||||
bit6: CODv2
|
||||
bit7: NSPF
|
||||
bit8: UDP Relay
|
||||
|
||||
Byte5
|
||||
bit1:VirtualLAN
|
||||
bit2:Static IP Multicast
|
||||
bit3:IP Redundancy
|
||||
bit4:CCM2
|
||||
bit5:ISDN Bonding
|
||||
bit6:Backup Link Selection -- for the VAN/Rdapter ver 4.0
|
||||
bit7:IP/IPX Forwarding -- for the WANgate ver 4.0
|
||||
bit8:Improved COD
|
||||
|
||||
Byte6
|
||||
bit1: Server Disptacher
|
||||
bit2: ISDN_US -- for the VANSX/WANGATE ver 5.0
|
||||
bit3: PPP
|
||||
bit4: IP Rip Filter -- for Vgate3
|
||||
bit5: Zero Hop Routing -- for Vgate3
|
||||
bit6: ISDN Japan
|
||||
bit7: PPP-Security
|
||||
|
||||
Byte7
|
||||
bit1: With unmanaged Switch
|
||||
bit2: 2 LANs
|
||||
bit3: OSPF Ver 2.0
|
||||
bit4: FACS Ver 2.0
|
||||
bit5: Multiple WEB Farm
|
||||
bit6: Backup Server
|
||||
bit7: Check Connectivity
|
||||
bit8: WSD multiplexing
|
||||
|
||||
Byte8
|
||||
bit1: MRT3
|
||||
bit2: WSD Redundancy
|
||||
bit3: DHCP Server
|
||||
bit4: WSD Connection Limit
|
||||
bit5: WSD Distributed System
|
||||
bit6: WSD Load Report
|
||||
bit7: WSD super farm
|
||||
bit8: RadWiz leased line
|
||||
|
||||
Byte9
|
||||
bit1: PPP IP address negotiaton
|
||||
bit2: DNS
|
||||
bit3: Nat
|
||||
bit4: WSD Static proximity
|
||||
bit5: WSD Dynamic proximity
|
||||
bit6: WSD Proxy
|
||||
bit7: WSD Proximity client
|
||||
bit8: MAC Load balancing
|
||||
|
||||
Byte10
|
||||
bit1: Unnum Inf
|
||||
bit2: Power Supply redundancy
|
||||
bit3: MRT PPP Compression
|
||||
bit4: ZHR Apolo
|
||||
bit5: Copy port
|
||||
bit6: UDP Relay 2.0
|
||||
bit7: NVRAM
|
||||
bit8: URL table
|
||||
|
||||
Byte11
|
||||
bit1: URL super farm
|
||||
bit2: NAT on LAN
|
||||
bit3: Remote Con
|
||||
bit4: AP5000
|
||||
bit5: Session tracking
|
||||
bit6: Mirroring
|
||||
bit7: Alias IP
|
||||
bit8: CSD Nat
|
||||
|
||||
Byte12
|
||||
bit1: content check
|
||||
bit2: mlb virtual ip
|
||||
bit3: reserved RadLan
|
||||
bit4: csd nat exception
|
||||
bit5: statistics monitor
|
||||
bit6: reserved-for-radware "
|
||||
|
||||
::= { rndDeviceParams 5 }
|
||||
|
||||
rndBrgLicense OBJECT-TYPE
|
||||
SYNTAX OCTET STRING -- SIZE 20
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This parameter is used for entering a s/w license number for a device.
|
||||
A separate license number is supplied for each device."
|
||||
::= { rndDeviceParams 6 }
|
||||
|
||||
-- IP Host Parameters
|
||||
|
||||
--All the new parameters under this section will be added to the
|
||||
-- rndMng group, as rndIpHost sub-group.
|
||||
--
|
||||
rndIpHost OBJECT IDENTIFIER ::= { rndDeviceParams 7 }
|
||||
--
|
||||
--ICMP Transmission Enable\Disable
|
||||
--The new variable will be
|
||||
|
||||
-- Obsolete
|
||||
-- rndICMPTransmitionEnable OBJECT-TYPE
|
||||
-- SYNTAX INTEGER {
|
||||
-- enable(1),
|
||||
-- disable(2)
|
||||
-- }
|
||||
-- MAX-ACCESS read-write
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "This variable controlls the ability to transmit ICMP frames"
|
||||
-- ::= { rndIpHost 1 }
|
||||
|
||||
rndCommunityTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RndCommunityEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The community table of the agent"
|
||||
::= { rndIpHost 2 }
|
||||
|
||||
rndCommunityEntry OBJECT-TYPE
|
||||
SYNTAX RndCommunityEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The row definition for this table."
|
||||
INDEX { rndCommunityMngStationAddr,
|
||||
IMPLIED rndCommunityString }
|
||||
::= { rndCommunityTable 1 }
|
||||
|
||||
RndCommunityEntry ::= SEQUENCE {
|
||||
rndCommunityMngStationAddr IpAddress,
|
||||
rndCommunityString DisplayString,
|
||||
rndCommunityAccess INTEGER,
|
||||
rndCommunityTrapsEnable INTEGER,
|
||||
rndCommunityStatus INTEGER,
|
||||
rndCommunityPortSecurity INTEGER,
|
||||
rndCommunityOwner DisplayString,
|
||||
rndCommunityTrapDestPort INTEGER
|
||||
}
|
||||
|
||||
|
||||
rndCommunityMngStationAddr OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The management station that will be allowed to
|
||||
communicate with the agent IP address"
|
||||
::= { rndCommunityEntry 1 }
|
||||
|
||||
rndCommunityString OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(1..20))
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The community string with which the management
|
||||
station will communicate with the agent"
|
||||
::= { rndCommunityEntry 2 }
|
||||
|
||||
rndCommunityAccess OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
readOnly(1),
|
||||
readWrite(2),
|
||||
super(3)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The allowed access to this management station"
|
||||
::= { rndCommunityEntry 3}
|
||||
|
||||
rndCommunityTrapsEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
snmpV1(1),
|
||||
snmpV2(2),
|
||||
snmpV3(3),
|
||||
trapsDisable(4)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Should the agent send traps to the management station,
|
||||
and what version is required"
|
||||
::= { rndCommunityEntry 4 }
|
||||
|
||||
rndCommunityStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
invalid(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of this entry. If the status is invalid the
|
||||
community entry will be deleted"
|
||||
::= { rndCommunityEntry 5 }
|
||||
|
||||
rndCommunityPortSecurity OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled(1),
|
||||
disabled(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If enabled the device will only receive SNMP messages from the port,
|
||||
through which this NMS is reachable from the device."
|
||||
DEFVAL { disabled }
|
||||
::= { rndCommunityEntry 6 }
|
||||
|
||||
rndCommunityOwner OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(1..32))
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The owner of this community"
|
||||
::= { rndCommunityEntry 7 }
|
||||
|
||||
rndCommunityTrapDestPort OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..65535)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The transport protocol (usually UDP) port to which traps to the
|
||||
management station represebted by this entry will be sent. The default
|
||||
is the well-known IANA assigned port number for SNMP traps.
|
||||
This object is relevant only if rndCommunityTrapsEnable has a value
|
||||
different from trapsDisable."
|
||||
DEFVAL { 162 }
|
||||
::= { rndCommunityEntry 8 }
|
||||
|
||||
rlMridTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlMridEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MRID related configurations table of the agent"
|
||||
::= { rndIpHost 3 }
|
||||
|
||||
rlMridEntry OBJECT-TYPE
|
||||
SYNTAX RlMridEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The row definition for this table."
|
||||
INDEX { rndCommunityMngStationAddr,
|
||||
IMPLIED rndCommunityString }
|
||||
::= { rlMridTable 1 }
|
||||
|
||||
RlMridEntry ::= SEQUENCE {
|
||||
rlMridConnection INTEGER,
|
||||
rlManagedMrid INTEGER
|
||||
}
|
||||
|
||||
rlMridConnection OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The router instance connecting the NMS who accessed the agent
|
||||
through the community table entry corresponding to the keys of this entry."
|
||||
::= { rlMridEntry 1 }
|
||||
|
||||
rlManagedMrid OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The router instance currently managed by the NMS who accessed the agent
|
||||
through the community table entry corresponding to the keys of this entry "
|
||||
::= { rlMridEntry 2 }
|
||||
|
||||
rndManagedTime OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(6))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time will be sent in the format hhmmss"
|
||||
::= { rndDeviceParams 8 }
|
||||
|
||||
rndManagedDate OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(6))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The date will be sent in the format ddmmyy"
|
||||
::= { rndDeviceParams 9 }
|
||||
|
||||
rndBaseBootVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines the boot version of the product."
|
||||
::= { rndDeviceParams 10 }
|
||||
|
||||
rndIpHostManagement OBJECT IDENTIFIER ::= { rndIpHost 4 }
|
||||
|
||||
rndIpHostManagementSupported OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"ifindex manage supported."
|
||||
::= { rndIpHostManagement 1 }
|
||||
|
||||
rndIpHostManagementIfIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"if supported manage , indicate ifindex, if 0 thaen disable"
|
||||
::= { rndIpHostManagement 2 }
|
||||
|
||||
genGroup OBJECT IDENTIFIER ::= { rndDeviceParams 11 }
|
||||
genGroupHWVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines the HW version of the product."
|
||||
::= { genGroup 1 }
|
||||
|
||||
genGroupConfigurationSymbol OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(1))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines the Configuration Symbol attached to any hardware module
|
||||
manufactured by LANNET. One single character A..Z defines the CS
|
||||
version."
|
||||
::= { genGroup 2 }
|
||||
|
||||
genGroupHWStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
ok(1),
|
||||
hardwareProblems(2),
|
||||
notSupported(255)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This attribute describes the status of the group hardware as detected
|
||||
by the sensors software."
|
||||
::= { genGroup 3 }
|
||||
|
||||
rndBasePhysicalAddress OBJECT-TYPE
|
||||
SYNTAX PhysAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Base physical (MAC) address of the device."
|
||||
::= { rndDeviceParams 12 }
|
||||
|
||||
RlImageIdType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"SW images enumeration"
|
||||
SYNTAX INTEGER { image1(1), image2(2) }
|
||||
|
||||
rndSoftwareFile OBJECT IDENTIFIER ::= { rndDeviceParams 13 }
|
||||
|
||||
rndActiveSoftwareFileTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RndActiveSoftwareFileEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The (conceptual) table listing the active software file of the
|
||||
requested unit."
|
||||
::= {rndSoftwareFile 1 }
|
||||
|
||||
rndActiveSoftwareFileEntry OBJECT-TYPE
|
||||
SYNTAX RndActiveSoftwareFileEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry (conceptual row) in the rndActiveSoftwareFileTable."
|
||||
INDEX {rndUnitNumber }
|
||||
::= {rndActiveSoftwareFileTable 1 }
|
||||
|
||||
RndActiveSoftwareFileEntry ::= SEQUENCE {
|
||||
rndUnitNumber INTEGER,
|
||||
rndActiveSoftwareFile RlImageIdType,
|
||||
rndActiveSoftwareFileAfterReset INTEGER
|
||||
}
|
||||
|
||||
rndUnitNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unit number (for stackable devices) or 1 for 'stand alone' device."
|
||||
::= {rndActiveSoftwareFileEntry 1 }
|
||||
|
||||
rndActiveSoftwareFile OBJECT-TYPE
|
||||
SYNTAX RlImageIdType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the current active software file, image1 or image2."
|
||||
::= {rndActiveSoftwareFileEntry 2 }
|
||||
|
||||
rndActiveSoftwareFileAfterReset OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
image1(1),
|
||||
image2(2),
|
||||
invalidImage(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the software file that will be active after reset (image1 or image2).
|
||||
If an error occurred in the download process, resulting in the corruption
|
||||
of the single software file, The value 'invalidImage' will be returned.
|
||||
This value can not be set by the user."
|
||||
::= {rndActiveSoftwareFileEntry 3 }
|
||||
|
||||
rlResetStatus
|
||||
OBJECT-TYPE
|
||||
SYNTAX BITS {
|
||||
ok(0),
|
||||
no-stack-integrity(1),
|
||||
downgrade(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A bit mask that specifies system status before reset action is preformed.
|
||||
Reset is prohibited in stackable products if the images selected after
|
||||
reboot are not of the same release version in ALL stack units.
|
||||
Downgrade status specifies that there are some actions to be preformed
|
||||
on the CDB file before reset is preformed.
|
||||
0x0 - OK
|
||||
0x1 - noStackIntegrity
|
||||
0x2 - downgrade"
|
||||
::= { rndSoftwareFile 2 }
|
||||
|
||||
|
||||
rndImageSize OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Max number of sectors currently allocated for image(s)."
|
||||
::= { rndDeviceParams 14 }
|
||||
|
||||
rndBackupConfigurationEnabled OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies whether the device supports backup-config parameters in lcli commands."
|
||||
::= { rndDeviceParams 15 }
|
||||
|
||||
rndImageInfo OBJECT IDENTIFIER ::= { rndDeviceParams 16 }
|
||||
|
||||
rndImageInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RndImageInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table contains information about images."
|
||||
::= {rndImageInfo 1 }
|
||||
|
||||
rndImageInfoEntry OBJECT-TYPE
|
||||
SYNTAX RndImageInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rndImageInfoTable."
|
||||
INDEX {rndStackUnitNumber }
|
||||
::= {rndImageInfoTable 1 }
|
||||
|
||||
RndImageInfoEntry ::= SEQUENCE {
|
||||
rndStackUnitNumber INTEGER,
|
||||
rndImage1Name DisplayString,
|
||||
rndImage2Name DisplayString,
|
||||
rndImage1Version DisplayString,
|
||||
rndImage2Version DisplayString,
|
||||
rndImage1Date DisplayString,
|
||||
rndImage2Date DisplayString,
|
||||
rndImage1Time DisplayString,
|
||||
rndImage2Time DisplayString,
|
||||
rndImage1Description DisplayString,
|
||||
rndImage2Description DisplayString
|
||||
}
|
||||
|
||||
rndStackUnitNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unit number (for stackable devices) or 1 for 'stand alone' device."
|
||||
::= {rndImageInfoEntry 1 }
|
||||
|
||||
rndImage1Name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the file name of image-1 in the system."
|
||||
::= {rndImageInfoEntry 2 }
|
||||
|
||||
rndImage2Name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the file name of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
|
||||
::= {rndImageInfoEntry 3 }
|
||||
|
||||
|
||||
rndImage1Version OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the version of image-1 in the system."
|
||||
::= {rndImageInfoEntry 4 }
|
||||
|
||||
rndImage2Version OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the version of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
|
||||
::= {rndImageInfoEntry 5 }
|
||||
|
||||
rndImage1Date OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the compilation date of image-1 in the system."
|
||||
::= {rndImageInfoEntry 6 }
|
||||
|
||||
rndImage2Date OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the compilation date of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
|
||||
::= {rndImageInfoEntry 7 }
|
||||
|
||||
rndImage1Time OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the compilation time of image-1 in the system."
|
||||
::= {rndImageInfoEntry 8 }
|
||||
|
||||
rndImage2Time OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the compilation time of image-2 (if present) in the system.If image-2 is not present show 'no info' text"
|
||||
::= {rndImageInfoEntry 9 }
|
||||
|
||||
rndImage1Description OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the description of image-1 in the system."
|
||||
::= {rndImageInfoEntry 10 }
|
||||
|
||||
rndImage2Description OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the description of image-2 in the system."
|
||||
::= {rndImageInfoEntry 11 }
|
||||
|
||||
rlComponentsInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlComponentsInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table contains information about components, their streams and baselines in the device images."
|
||||
::= {rndImageInfo 2}
|
||||
|
||||
rlComponentsInfoEntry OBJECT-TYPE
|
||||
SYNTAX RlComponentsInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the rlComponentsInfoTable."
|
||||
INDEX {rlComponentsInfoStackUnitNumber, rlComponentsInfoImageId,
|
||||
IMPLIED rlComponentsInfoComponent}
|
||||
::= {rlComponentsInfoTable 1 }
|
||||
|
||||
RlComponentsInfoEntry ::= SEQUENCE {
|
||||
rlComponentsInfoStackUnitNumber INTEGER,
|
||||
rlComponentsInfoImageId RlImageIdType,
|
||||
rlComponentsInfoComponent DisplayString,
|
||||
rlComponentsInfoBaseline DisplayString
|
||||
}
|
||||
|
||||
rlComponentsInfoStackUnitNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unit number (for stackable devices) or 1 for 'stand alone' device."
|
||||
::= {rlComponentsInfoEntry 1}
|
||||
|
||||
|
||||
rlComponentsInfoImageId OBJECT-TYPE
|
||||
SYNTAX RlImageIdType
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the image id in the unit"
|
||||
::= {rlComponentsInfoEntry 2}
|
||||
|
||||
rlComponentsInfoComponent OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE (1..40))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the SW component name."
|
||||
::= {rlComponentsInfoEntry 3}
|
||||
|
||||
rlComponentsInfoBaseline OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the version control baseline of the SW component name."
|
||||
::= {rlComponentsInfoEntry 5}
|
||||
|
||||
|
||||
END
|
||||
|
253
MIBS/eltexmes23xx/RADLAN-File
Normal file
253
MIBS/eltexmes23xx/RADLAN-File
Normal file
@ -0,0 +1,253 @@
|
||||
RADLAN-File DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: RADLAN File Private Extension
|
||||
-- Version: 7.39.00.00
|
||||
-- Date: 23 Feb 2005
|
||||
-- 23-Sep-2003 Added field rlFileRowStatus to rlFileTable
|
||||
-- 23-Sep-2003 Removed field rlFileActionNextLine from rlFileActionTable
|
||||
-- 23-Sep-2003 Removed values "display" and "delete" of rlFileActionCommand
|
||||
-- 07-Nov-2004 Added Scalar rlFileAuditingEnable
|
||||
-- 23-Feb-2005 Added rlFileFlashSize
|
||||
|
||||
|
||||
IMPORTS
|
||||
rnd FROM RADLAN-MIB
|
||||
DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue FROM SNMPv2-TC
|
||||
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
|
||||
|
||||
|
||||
rlFile MODULE-IDENTITY
|
||||
LAST-UPDATED "201304010000Z" -- April 1, 2013
|
||||
ORGANIZATION "Marvell Semiconductor, Inc."
|
||||
CONTACT-INFO
|
||||
"www.marvell.com"
|
||||
DESCRIPTION
|
||||
"The MIB module describes the private MIB for File Private Extension
|
||||
supported by Marvell MTS software and products."
|
||||
REVISION "201304010000Z" -- April 1, 2013
|
||||
DESCRIPTION
|
||||
"Added MODULE-IDENTITY"
|
||||
::= { rnd 96 }
|
||||
|
||||
FilePermission ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"File permission"
|
||||
SYNTAX BITS {
|
||||
read(0),
|
||||
write(1),
|
||||
execute(2),
|
||||
dir(3)
|
||||
}
|
||||
|
||||
|
||||
rlFileMibVersion OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the File System MIB version. The current version is 1."
|
||||
::= {rlFile 1 }
|
||||
|
||||
rlFileTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlFileEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The (conceptual) table listing all the files
|
||||
of the flash file system."
|
||||
::= {rlFile 2 }
|
||||
|
||||
rlFileEntry OBJECT-TYPE
|
||||
SYNTAX RlFileEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry (conceptual row) in the FileTable."
|
||||
INDEX { IMPLIED rlFileName }
|
||||
::= {rlFileTable 1 }
|
||||
|
||||
RlFileEntry ::= SEQUENCE {
|
||||
rlFileName OCTET STRING,
|
||||
rlFilePermission FilePermission,
|
||||
rlFileSize INTEGER,
|
||||
rlFileModificationDate DisplayString,
|
||||
rlFileModificationTime DisplayString,
|
||||
rlFileRowStatus RowStatus,
|
||||
rlFileFlashSize INTEGER,
|
||||
rlFileFullNormalizedName OCTET STRING
|
||||
}
|
||||
|
||||
rlFileName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING(SIZE(1..160))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name of the file."
|
||||
::= { rlFileEntry 1 }
|
||||
|
||||
rlFilePermission OBJECT-TYPE
|
||||
SYNTAX FilePermission
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"permission level bitmap. "
|
||||
::= { rlFileEntry 2 }
|
||||
|
||||
rlFileSize OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The size of the file in bytes (actual size)."
|
||||
::= { rlFileEntry 3 }
|
||||
|
||||
rlFileModificationDate OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time-stamp indicating the date of creation or last
|
||||
modification of this file. The format of the time-stamp is
|
||||
dd-mmm-yyyy"
|
||||
::= { rlFileEntry 4 }
|
||||
|
||||
rlFileModificationTime OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time-stamp indicating the time of creation or last
|
||||
modification of this file. The format of the time-stamp is
|
||||
hh:mm:ss"
|
||||
::= { rlFileEntry 5 }
|
||||
|
||||
rlFileRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"It is used just to delete an entry"
|
||||
::= { rlFileEntry 6 }
|
||||
|
||||
rlFileFlashSize OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The size allocated for the file in bytes (allocated size)."
|
||||
::= { rlFileEntry 7 }
|
||||
|
||||
rlFileFullNormalizedName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The full normalized name - up to max OCTET STRING length and
|
||||
not containing '..' and '.' path components."
|
||||
::= { rlFileEntry 8 }
|
||||
|
||||
rlFileActionTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlFileActionEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The (conceptual) table listing only one entry at a time
|
||||
with parameters needed for performing an action on a file."
|
||||
::= {rlFile 3 }
|
||||
|
||||
rlFileActionEntry OBJECT-TYPE
|
||||
SYNTAX RlFileActionEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry (conceptual row) in the FileActionTable."
|
||||
INDEX {rlFileActionName }
|
||||
::= {rlFileActionTable 1 }
|
||||
|
||||
RlFileActionEntry ::= SEQUENCE {
|
||||
rlFileActionName OCTET STRING,
|
||||
rlFileActionNewName OCTET STRING,
|
||||
rlFileActionRowStatus RowStatus,
|
||||
rlFileActionCommand INTEGER
|
||||
}
|
||||
|
||||
rlFileActionName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..160))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name of the file."
|
||||
::= { rlFileActionEntry 1 }
|
||||
|
||||
rlFileActionNewName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..160))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The new name for the file (in case of action rename)."
|
||||
::= { rlFileActionEntry 2 }
|
||||
|
||||
rlFileActionRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"It is used to create an entry"
|
||||
::= { rlFileActionEntry 3 }
|
||||
|
||||
rlFileActionCommand OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
rename(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Perform an action on the file."
|
||||
::= { rlFileActionEntry 4 }
|
||||
|
||||
rlFileTotalSizeOfFlash OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the total size of the flash in bytes."
|
||||
::= {rlFile 4 }
|
||||
|
||||
rlFileFreeSizeOfFlash OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the number of free bytes in the flash."
|
||||
::= {rlFile 5 }
|
||||
|
||||
--- File System auditing control (SysLog)
|
||||
|
||||
rlFileAuditingEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Controls whether SysLog messages
|
||||
should be issued on file rename/delete events"
|
||||
DEFVAL { true }
|
||||
::= { rlFile 6 }
|
||||
|
||||
rlFileTotalSizeOfUSB OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the total size of the USB in bytes."
|
||||
::= {rlFile 7 }
|
||||
|
||||
rlFileFreeSizeOfUSB OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the number of free bytes in the USB."
|
||||
::= {rlFile 8 }
|
||||
|
||||
END
|
473
MIBS/eltexmes23xx/RADLAN-HWENVIROMENT
Normal file
473
MIBS/eltexmes23xx/RADLAN-HWENVIROMENT
Normal file
@ -0,0 +1,473 @@
|
||||
RADLAN-HWENVIROMENT DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
rnd FROM RADLAN-MIB
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION, DisplayString,TruthValue FROM SNMPv2-TC;
|
||||
|
||||
rlEnv MODULE-IDENTITY
|
||||
LAST-UPDATED "200309210000Z"
|
||||
ORGANIZATION "Radlan Computer Communications Ltd."
|
||||
CONTACT-INFO
|
||||
"radlan.com"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for environment of Radlan devices."
|
||||
REVISION "200309210000Z"
|
||||
DESCRIPTION
|
||||
"Added this MODULE-IDENTITY clause."
|
||||
::= { rnd 83 }
|
||||
|
||||
RlEnvMonState ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the state of a device being monitored.
|
||||
Valid values are:
|
||||
|
||||
normal(1): the environment is good, such as low
|
||||
temperature or full battery charge.
|
||||
|
||||
warning(2): the environment is bad, such as temperature
|
||||
above normal operation range but not too
|
||||
high, or battery discharge.
|
||||
|
||||
critical(3): the environment is very bad, such as
|
||||
temperature much higher than normal
|
||||
operation limit or critically low battery charge.
|
||||
|
||||
shutdown(4): the environment is the worst, the system
|
||||
should be shutdown immediately.
|
||||
|
||||
notPresent(5): the environmental monitor is not present,
|
||||
such as temperature sensors or battery does not exist.
|
||||
|
||||
notFunctioning(6): the environmental monitor does not
|
||||
function properly, such as a temperature
|
||||
sensor generates a abnormal data like
|
||||
1000 or error happens while reading battery
|
||||
state.
|
||||
|
||||
restore(7): the environment is restoring its normal state,
|
||||
such as battery recharging.
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
warning(2),
|
||||
critical(3),
|
||||
shutdown(4),
|
||||
notPresent(5),
|
||||
notFunctioning(6),
|
||||
restore(7),
|
||||
notAvailable(8),
|
||||
backingUp(9)
|
||||
}
|
||||
|
||||
|
||||
RlEnvMonDirection ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the state of a device being monitored.
|
||||
Valid values are:
|
||||
|
||||
unKnown(1): if the board not support air flow direction.
|
||||
|
||||
frontToBack(2): the air flow direction of the fan is front to back.
|
||||
|
||||
backToFront(3): the air flow direction of the fan is back to front.
|
||||
|
||||
clockwise(4): the air flow direction of the fan is clock wise
|
||||
|
||||
unClockwise(5): the air flow direction of the fan is unclock wise
|
||||
|
||||
insideOutside(6): the air flow direction of the fan is inside outside
|
||||
|
||||
outsideInside(7): the air flow direction of the fan is outside inside
|
||||
|
||||
rightToLeft(8): the air flow direction of the fan is from right to left
|
||||
|
||||
leftToRight(9): the air flow direction of the fan is from left to right
|
||||
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
unKnown(1),
|
||||
frontToBack(2),
|
||||
backToFront(3),
|
||||
clockwise(4),
|
||||
unClockwise(5),
|
||||
insideOut(6),
|
||||
outsideIn(7),
|
||||
rightToLeft(8),
|
||||
leftToRight(9)
|
||||
}
|
||||
|
||||
rlEnvPhysicalDescription OBJECT IDENTIFIER ::= { rlEnv 1 }
|
||||
|
||||
rlEnvMonFanStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of fan status maintained by the environmental
|
||||
monitor."
|
||||
::= { rlEnvPhysicalDescription 1 }
|
||||
|
||||
rlEnvMonFanStatusEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the fan status table, representing the status of
|
||||
the associated fan maintained by the environmental monitor."
|
||||
INDEX { rlEnvMonFanStatusIndex }
|
||||
::= { rlEnvMonFanStatusTable 1 }
|
||||
|
||||
RlEnvMonFanStatusEntry ::=
|
||||
SEQUENCE {
|
||||
rlEnvMonFanStatusIndex INTEGER,
|
||||
rlEnvMonFanStatusDescr DisplayString,
|
||||
rlEnvMonFanState RlEnvMonState
|
||||
}
|
||||
|
||||
rlEnvMonFanStatusIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the fan being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { rlEnvMonFanStatusEntry 1 }
|
||||
|
||||
rlEnvMonFanStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the fan being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { rlEnvMonFanStatusEntry 2 }
|
||||
|
||||
rlEnvMonFanState OBJECT-TYPE
|
||||
SYNTAX RlEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The mandatory state of the fan being instrumented."
|
||||
::= { rlEnvMonFanStatusEntry 3 }
|
||||
|
||||
|
||||
|
||||
rlEnvMonSupplyStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvMonSupplyStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of power supply status maintained by the
|
||||
environmental monitor card."
|
||||
::= { rlEnvPhysicalDescription 2 }
|
||||
|
||||
rlEnvMonSupplyStatusEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvMonSupplyStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the power supply status table, representing the
|
||||
status of the associated power supply maintained by the
|
||||
environmental monitor card."
|
||||
INDEX { rlEnvMonSupplyStatusIndex }
|
||||
::= { rlEnvMonSupplyStatusTable 1 }
|
||||
|
||||
RlEnvMonSupplyStatusEntry ::=
|
||||
SEQUENCE {
|
||||
rlEnvMonSupplyStatusIndex INTEGER ,
|
||||
rlEnvMonSupplyStatusDescr DisplayString,
|
||||
rlEnvMonSupplyState RlEnvMonState,
|
||||
rlEnvMonSupplySource INTEGER,
|
||||
rlEnvMonSupplyFanDirection RlEnvMonDirection
|
||||
}
|
||||
|
||||
rlEnvMonSupplyStatusIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the power supply being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { rlEnvMonSupplyStatusEntry 1 }
|
||||
|
||||
rlEnvMonSupplyStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the power supply being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { rlEnvMonSupplyStatusEntry 2 }
|
||||
|
||||
rlEnvMonSupplyState OBJECT-TYPE
|
||||
SYNTAX RlEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The mandatory state of the power supply being instrumented."
|
||||
::= { rlEnvMonSupplyStatusEntry 3 }
|
||||
|
||||
rlEnvMonSupplySource OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
unknown(1),
|
||||
ac(2),
|
||||
dc(3),
|
||||
externalPowerSupply(4),
|
||||
internalRedundant(5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The power supply source.
|
||||
unknown - Power supply source unknown
|
||||
ac - AC power supply
|
||||
dc - DC power supply
|
||||
externalPowerSupply - External power supply
|
||||
internalRedundant - Internal redundant power supply
|
||||
"
|
||||
::= { rlEnvMonSupplyStatusEntry 4 }
|
||||
|
||||
rlEnvMonSupplyFanDirection OBJECT-TYPE
|
||||
SYNTAX RlEnvMonDirection
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The direction of the power supply's fan."
|
||||
::= { rlEnvMonSupplyStatusEntry 5 }
|
||||
|
||||
--------------------------------------------------------------------------------
|
||||
-- rlEnvMonIndexTable
|
||||
--------------------------------------------------------------------------------
|
||||
|
||||
rlEnvMonIndexTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvMonIndexEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table that can help building indexes for EnvMon tables."
|
||||
::= { rlEnvPhysicalDescription 10 }
|
||||
|
||||
rlEnvMonIndexEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvMonIndexEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in table, representing the index input parameters."
|
||||
INDEX { rlEnvMonIndexUnitId, rlEnvMonIndexObjType, rlEnvMonIndexObjIndex }
|
||||
::= { rlEnvMonIndexTable 1 }
|
||||
|
||||
RlEnvMonIndexEntry ::=
|
||||
SEQUENCE {
|
||||
rlEnvMonIndexUnitId INTEGER,
|
||||
rlEnvMonIndexObjType INTEGER,
|
||||
rlEnvMonIndexObjIndex INTEGER,
|
||||
rlEnvMonIndexValue INTEGER
|
||||
}
|
||||
|
||||
rlEnvMonIndexUnitId OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unit ID."
|
||||
::= { rlEnvMonIndexEntry 1 }
|
||||
|
||||
rlEnvMonIndexObjType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerSupply(5),
|
||||
fan(6),
|
||||
thermalSensorUnderCard(14)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Object type."
|
||||
::= { rlEnvMonIndexEntry 2 }
|
||||
|
||||
rlEnvMonIndexObjIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Index of object."
|
||||
::= { rlEnvMonIndexEntry 3 }
|
||||
|
||||
rlEnvMonIndexValue OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Calculated index value."
|
||||
::= { rlEnvMonIndexEntry 4 }
|
||||
|
||||
rlEnvFanData OBJECT IDENTIFIER ::= { rlEnv 5 }
|
||||
|
||||
rlEnvFanDataTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvFanDataEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"For each unit in a stack"
|
||||
::= { rlEnvFanData 1 }
|
||||
|
||||
rlEnvFanDataEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvFanDataEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry of this table specifies a unit"
|
||||
INDEX { rlEnvFanDataStackUnit }
|
||||
::= { rlEnvFanDataTable 1 }
|
||||
|
||||
RlEnvFanDataEntry ::= SEQUENCE {
|
||||
rlEnvFanDataStackUnit INTEGER,
|
||||
rlEnvFanDataTemp INTEGER,
|
||||
rlEnvFanDataSpeed INTEGER,
|
||||
rlEnvFanDataOperLevel INTEGER,
|
||||
rlEnvFanDataAdminLevel INTEGER,
|
||||
rlEnvFanDataDirection RlEnvMonDirection
|
||||
}
|
||||
|
||||
rlEnvFanDataStackUnit OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of the stack unit"
|
||||
::= { rlEnvFanDataEntry 1 }
|
||||
|
||||
rlEnvFanDataTemp OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unit temperature"
|
||||
::= { rlEnvFanDataEntry 2 }
|
||||
|
||||
rlEnvFanDataSpeed OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Fan speed in RPM"
|
||||
::= { rlEnvFanDataEntry 3 }
|
||||
|
||||
rlEnvFanDataOperLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Fan speed operative level"
|
||||
::= { rlEnvFanDataEntry 4 }
|
||||
|
||||
rlEnvFanDataAdminLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configured fan speed level"
|
||||
::= { rlEnvFanDataEntry 5 }
|
||||
|
||||
rlEnvFanDataDirection OBJECT-TYPE
|
||||
SYNTAX RlEnvMonDirection
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The direction of the system's fan."
|
||||
::= { rlEnvFanDataEntry 6 }
|
||||
|
||||
|
||||
-- ************ Redundant Fan ************** --
|
||||
|
||||
RlEnvRedundantFanStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the status of a redundant fan.
|
||||
Valid values are:
|
||||
Ready(1): fan is ready and not active (all fans are O.K)
|
||||
Active(2): fan is active (one or more fan failed)
|
||||
Failure(3): fan failure "
|
||||
|
||||
SYNTAX INTEGER {
|
||||
ready(1),
|
||||
active(2),
|
||||
failure(3),
|
||||
notPresent(4)
|
||||
}
|
||||
|
||||
rlEnvRedundantFanTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvRedundantFanEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table of redundant fan status"
|
||||
::= { rlEnv 6 }
|
||||
|
||||
rlEnvRedundantFanEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvRedundantFanEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the redundant fan status table, representing the status of the associated fan "
|
||||
INDEX { rlEnvRedundantFanUnitId, rlEnvRedundantFanIndex }
|
||||
::= { rlEnvRedundantFanTable 1 }
|
||||
|
||||
RlEnvRedundantFanEntry ::=
|
||||
SEQUENCE {
|
||||
rlEnvRedundantFanUnitId Unsigned32,
|
||||
rlEnvRedundantFanIndex INTEGER,
|
||||
rlEnvRedundantFanStatus RlEnvRedundantFanStatus
|
||||
}
|
||||
|
||||
rlEnvRedundantFanUnitId OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of the stack unit"
|
||||
::= { rlEnvRedundantFanEntry 1 }
|
||||
|
||||
rlEnvRedundantFanIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The fan index"
|
||||
::= { rlEnvRedundantFanEntry 2 }
|
||||
|
||||
rlEnvRedundantFanStatus OBJECT-TYPE
|
||||
SYNTAX RlEnvRedundantFanStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The fan status"
|
||||
::= { rlEnvRedundantFanEntry 3 }
|
||||
|
||||
rlEnvRedundantFanSupported OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Defines whether Redundant Fan feature is supported"
|
||||
::= { rlEnv 7 }
|
||||
|
||||
END
|
||||
|
734
MIBS/eltexmes23xx/RADLAN-MIB
Normal file
734
MIBS/eltexmes23xx/RADLAN-MIB
Normal file
@ -0,0 +1,734 @@
|
||||
RADLAN-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: RADLAN ROS
|
||||
-- Version: 7.46
|
||||
-- Date: 23-Jan-2007
|
||||
--
|
||||
-- 05-Jun-2003 Added rlHostParamTable
|
||||
-- 12-Jun-2003 Added enumeration to rndErrorSeverity
|
||||
-- 14-Jun-2003 Added field rlCopyHistoryErrorMessage to table rlCopyHistoryTable
|
||||
-- 29-Jun-2003 Tables rlOspf...LnkTable replayed tables rlOspf...LSATable)
|
||||
-- 08-Jul-2003 The low range boundary and the default value of rlDvmrpPruneLifetime
|
||||
-- were changed from 300 to 200 seconds
|
||||
-- 16-Jul-2003 The following values VesuvioT and VesuvioF were added to
|
||||
-- rlPhDModuleType
|
||||
-- 22-Jul-2003 Added rlStartupCDBChanged, rlManualReboot
|
||||
-- 23-Jul-2003 New group rldot1x was added
|
||||
-- 24-Jul-2003 Changed ipMRouteStdMIB to rlIpMRouteStdMIB
|
||||
-- 27-Jul-2003 Changed access of rlMaxNumberOfAccessRules to read-only
|
||||
-- 27-Jul-2003 Changed access of rlMaxNumberOfAccessRulesAfterReset to read-write
|
||||
-- 30-Jul-2003 Added 802.1x traps rldot1xPortStatusAuthorizedTrap and
|
||||
-- rldot1xPortStatusUnauthorizedTrap
|
||||
-- 30-Jul-2003 Added rlFile
|
||||
-- 31-Jul-2003 Added rlAAAEap
|
||||
-- 10-Aug-2003 Renamed enumeration values resetCDB to resetStartupCDB and
|
||||
-- eraseCDB to eraseStartupCDB and
|
||||
-- added enumeration values eraseRunningCDB and copyStartupToRunning
|
||||
-- 16-Aug-2003 Added rlSnmp
|
||||
-- 18-Aug-2002 Added rldot1xExtAuthSessionStatsTable
|
||||
-- 21-Aug-2003 Added rlOspfTuning
|
||||
-- 09-Sep-2003 Added rlPortCopyVlanTaggingTable
|
||||
-- 13-Sep-2003 Added IMPLIED to INDEX { IMPLIED rlTranslationNameToIpName }
|
||||
-- 15-Sep-2003 rlPhysicalDescription's version (a value of variable rlPhDMibVersion)
|
||||
-- was changed from 2 to 3
|
||||
-- 15-Sep-2003 Added field rldot1dStpPortRole to rldot1dStpPortTable
|
||||
-- 15-Sep-2003 Added field rldot1sMStpInstancePortRole to rldot1sMstpInstancePortTable
|
||||
-- 15-Sep-2003 Added field rldot1sMstpExtPortBoundary to rldot1sMstpExtPortEntryTable
|
||||
-- 19-Sep-2003 Added rldot1xGuestVlanSupported, rldot1xGuestVlanVID, rldot1xGuestVlanPorts,
|
||||
-- rldot1xUnAuthenticatedVlanSupported, rldot1xUnAuthenticatedVlanTable,
|
||||
-- rldot1xUserBasedVlanSupported, rldot1xUserBasedVlanPorts
|
||||
-- 26-Sep-2003 Added rlMridTable
|
||||
-- 26-Sep-2003 Added rlMirModel
|
||||
-- 26-Sep-2003 Deleted JackType from IMPORTS clause
|
||||
-- 26-Sep-2003 Changed naming of SMIv2-like types
|
||||
-- 26-Sep-2003 Moved rlSyslog branch to new MIB
|
||||
-- 26-Sep-2003 Moved rlCopy branch to new MIB
|
||||
-- 26-Sep-2003 Editorial changes
|
||||
-- 02-Oct-2003 Added vlanSpecialTagTable
|
||||
-- 02-Oct-2003 Added field branch rlMibTree and table rlMibTreeTable
|
||||
-- 02-Oct-2003 rlPhysicalDescription's version (a value of variable rlPhDMibVersion)
|
||||
-- was changed from 3 to 4
|
||||
-- 02-Oct-2003 Added vlanSpecialTagCurrentTable
|
||||
-- 09-Oct-2003 Added field rldot1sMstpInstanceRemainingHopes to rldot1sMstpInstanceTable
|
||||
-- 11-Oct-2003 Changed OSPF tuning
|
||||
-- 24-Oct-2003 Change range of rldot1sMstpInstancePortPathCost
|
||||
-- from (1..65535) to (1..200000000)
|
||||
-- 26-Oct-2003 Added rsMaxNumberRpAddresesInGroupRange,rsMaxNumberRpAddresesInGroupRangeAfterReset
|
||||
-- 26-Oct-2003 Removed rlPimSMBootStrapInfoEnable
|
||||
-- 27-Oct-2003 Change range of rldot1sMStpInstancePortAdminPathCost
|
||||
-- from (0..65535) to (0..200000000)
|
||||
-- 29-Oct-2003 Added rlIfExistingPortList
|
||||
-- 07-Nov-2003 rldot1sMstpMaxHopes:
|
||||
-- a. range was changed from 1..20 to 1..40
|
||||
-- b. default value was chaged from 10 to 20
|
||||
-- rldot1sMstpDesignatedMaxHopes:
|
||||
-- a. range was changed from 1..40 to 1..20
|
||||
-- 02-Dec-2003 Unused group rsIpZeroHopRouting was deleted
|
||||
-- 03-Dec-2003 Added rlSNMPDomains branch
|
||||
-- 03-Dec-3003 Added rlTstBasicRateTable
|
||||
-- 14-Dec-2003 Added field rldot1dStpBpduType to rldot1dStpPortEntry
|
||||
-- 14-Dec-2003 Added rldot1dStpFilterBpdu
|
||||
-- 21-Dec-2003 Updated imports of DisplayString, PhysAddress, TimeInterval,
|
||||
-- DateAndTime, ipAddrEntry
|
||||
-- 21-Dec-3003 Added rlEmWebHttpsActiveCertificateId and rlSsl
|
||||
-- 24-Dec-3003 Added rldot1sMstpRemainingHops
|
||||
-- 13-Jan-2004 Change MSTP tables indexes to read-only.
|
||||
-- 30-Jan-2004 add field rldot1sMstpExtPortInternalAdminPathCost to rldot1sMstpExtPortTable.
|
||||
-- 30-Jan-2004 change field rldot1sMstpExtPortInternalPathCost to rldot1sMstpExtPortInternalOperPathCost
|
||||
-- and make it read-only, change range to (0..200000000).
|
||||
-- 03-Feb-2004 traps 186-191 are implemeted in the Physicaldescription MIB - for stacking.
|
||||
-- 09-Feb-2004 Change the upper rage of rldot1sMstpVlan to 4094.
|
||||
-- 11-Mar-2004 Added swIfPortLockIfRangeTable
|
||||
-- 26-Mar-2004 rlLcli MIB was moved to separated file
|
||||
-- 30-Mar-2004 Added traps swIfTablePortLock and swIfTablePortUnLock
|
||||
-- 19-Apr-2004 Moved to separate MIBS IP Multicast & DVMRP
|
||||
-- 24-Apr-2004 Moved to separate MIBS VLAN
|
||||
-- 05-May-2004 Deleted default values in swIfEntry
|
||||
-- 07-May-2004 Added mac base priority MIB as RND 101
|
||||
-- 16-May-2004 Added value invalidImage(3) to rndActiveSoftwareFileAfterReset
|
||||
-- of rndActiveSoftwareFileTable
|
||||
-- 18-May-2004 Moved to separate files: ipSpec, rlBgp, rsTunning, rlFft,
|
||||
-- rndMng, rndApplications
|
||||
-- 31-May-2004 Added rlWlanAccessPoint
|
||||
-- 31-May-2004 Moved to separate files: rsUDP, swInterfaces, rlRmonControl
|
||||
-- 09-Jun-2004 change field rldot1sMstpInstancePortEnable in rldot1sMstpInstancePortEntry
|
||||
-- to read-only
|
||||
-- 16-Jun-2004 Added rndIpHostManagementSupported and rndIpHostManagementIfIndex
|
||||
-- 10-Nov-2004 Added rndNotifications
|
||||
-- 11-Nov-2004 Added rlAAAUserLocked trap
|
||||
-- 23-Nov-2004 Added type kiloBitsPerSecond RlStormCtrlRateUnit.
|
||||
-- 29-Nov-2004 limit rldot1sMstpPendingConfigurationName to 32 characters.
|
||||
-- 17-Jan-2005 Add rldot1dStpPortRestrictedRole field to rldot1dStpPortEntry
|
||||
-- 16-Mar-2005 Add rlLocalization branch
|
||||
-- 14-Apr-2005 Add rlRs232
|
||||
-- 18-Apr-2005 Add rldot1dStpPortAutoEdgePort to rldot1dStpPortEntry
|
||||
-- 27-Apr-2005 ZachM add rlStackLinkChange trap.
|
||||
-- 16-Jun-2005 Added rlNicRedundancy
|
||||
-- 01-Jul-2005 Added rlIgmpSnoopMulticastTvTable
|
||||
-- 07-Dec-2005 Added rlUPnP branch
|
||||
-- 12-Dec-2005 Added rldot1dStpFloodBpduMethod
|
||||
-- 14-Dec-2005 Add rlLldp branch
|
||||
-- 02-Feb-2006 GalVA added rlEmWebExtraPort
|
||||
-- 02-Feb-2006 GalVA added rlEmWebExtraPortType
|
||||
-- 12-Feb-2006 Import V2 textual conventions from SNMPv2-TC-v1 instead of SNMPv2-TC and RADLAN-SNMPv2
|
||||
-- 12-Feb-2006 Removed private trunk MIB to separate MIB module.
|
||||
-- 06-Mar-2006 Added rldot1dStpSeparatedBridges
|
||||
-- 13-Mar-2006 GalVA added rlEmWebMaxHttpsIdleTimeout
|
||||
-- 26-Mar-2006 Removed IMPORTs from IEEE8023-LAG-MIB + editorial change in rldot1dStpSeparatedBridges
|
||||
-- 24-May-2006 Added BPDU Guard support
|
||||
-- 31-May-2006 Added rldot1xAuthenticationPortTable OBJECT-TYPE
|
||||
-- 08-Jun-2006 Added rlDhcpSpoofing
|
||||
-- 08-Jun-2006 Added rldot1xAuthMultiStatsTable, rldot1xAuthMultiDiagTable, rldot1xAuthMultiSessionStatsEntry
|
||||
-- 02-Jul-2006 Added Bonjour branch
|
||||
-- 02-Jul-2006 Added rlLinksysSmartMIB branch
|
||||
-- 05-Jul-2006 Added rldot1xAuthConfigTable
|
||||
-- 10-Jul-2006 Moved branch rlMacMulticast to rlbridgemulticast
|
||||
-- 07-Aug-2006 Moved definitios of traps rlCopyFinished and rlCopyFailed TRAP-TYPE
|
||||
-- to ADLAN-COPY-MIB
|
||||
-- 23-Aug-2006 Added rlGlobalIpAddrTable
|
||||
-- 29-Aug-2006 Added rndImageSize
|
||||
-- 21-Sep-2006 Added rldot1xBpduFilteringEnabled
|
||||
-- 07-Sep-2006 Moved all rlEmbWeb definitions to rlembweb.mib
|
||||
-- 06-Oct-2006 Added rndBackupConfigurationEnabled
|
||||
-- 09-Oct-2006 Added rndImageInfoTable
|
||||
-- 03-Nov-2006 Added dlPrivate
|
||||
-- 18-Dec-2006 Added rlDhcpClCommandTable
|
||||
-- 02-Jan-2007 rndDeviceParams MIB was moved to separate file RADLAN-DEVICEPARAMS-MIB.MIB
|
||||
-- 02-Jan-2007 rndBootP MIB was moved to separate file RADLAN-BOOTP-MIB.MIB
|
||||
-- 02-Jan-2007 rlBrgMacSwitch MIB was moved to separate file RADLAN-BRGMACSWITCH-MIB.MIB
|
||||
-- 02-Jan-2007 rlpBridgeMIBObjects MIB was moved to separate file RADLAN-BRIDGEMIBOBJECTS-MIB.MIB
|
||||
-- 02-Jan-2007 rlCli MIB was moved to separate file RADLAN-CLI-MIB.MIB
|
||||
-- 02-Jan-2007 rlTelnet MIB was moved to separate file RADLAN-TELNET-MIB.MIB
|
||||
-- 02-Jan-2007 rlArpSpoofing MIB was moved to separate file RADLAN-ARPSPOOFING-MIB.MIB
|
||||
-- 02-Jan-2007 rlMir MIB was moved to separate file RADLAN-MIR-MIB.MIB
|
||||
-- 02-Jan-2007 rlGvrp MIB was moved to separate file RADLAN-GVRP-MIB.MIB
|
||||
-- 02-Jan-2007 rlSwPackageVersion MIB was moved to separate file RRADLAN-SWPACKAGEVERSION-MIB.MIB
|
||||
-- 02-Jan-2007 rlRCli MIB was moved to separate file RADLAN-RCLI-MIB.MIB
|
||||
-- 02-Jan-2007 rlAggregateVlan MIB was moved to separate file RADLAN-AGGREGATEVLAN-MIB.MIB
|
||||
-- 02-Jan-2007 rlGmrp MIB was moved to separate file RADLAN-GMRP-MIB.MIB
|
||||
-- 02-Jan-2007 rlDhcpCl MIB was moved to separate file RADLAN-DHCPCL-MIB.MIB
|
||||
-- 02-Jan-2007 rlStormCtrl MIB was moved to separate file RADLAN-STORMCTRL-MIB.MIB
|
||||
-- 02-Jan-2007 rlSmon MIB was moved to separate file RADLAN-SMON-MIB.MIB
|
||||
-- 02-Jan-2007 rlDigitalKeyManage MIB was moved to separate file RADLAN-DIGITALKEYMANAGE-MIB.MIB
|
||||
-- 02-Jan-2007 rldot1x MIB was moved to separate file RADLAN-DOT1X-MIB.MIB
|
||||
-- 02-Jan-2007 rlSocket MIB was moved to separate file RADLAN-SOCKET-MIB.MIB
|
||||
-- 02-Jan-2007 rl3sw2swTables MIB was moved to separate file RADLAN-3SW2SWTABLES-MIB.MIB
|
||||
-- 02-Jan-2007 rlMultiSessionTerminal MIB was moved to separate file RADLAN-MULTISESSIONTERMINAL-MIB.MIB
|
||||
-- 02-Jan-2007 rlTraceRoute MIB was moved to separate file RADLAN-TRACEROUTE-MIB.MIB
|
||||
-- 02-Jan-2007 rlJumboFrames MIB was moved to separate file RADLAN-JUMBOFRAMES-MIB.MIB
|
||||
-- 02-Jan-2007 rlCDB MIB was moved to separate file RADLAN-CDB-MIB.MIB
|
||||
-- 02-Jan-2007 rndEndOfMibGroup MIB was moved to separate file RADLAN-ENDOFMIB-MIB.MIB
|
||||
-- 15-Jan-2007 Devided file appolo.txt to a few files
|
||||
-- Renamed file appolo.txt to ralan-mib.mib
|
||||
-- 22-Jan-2007 Added rlIntel
|
||||
-- 28-Mar-2007 added rlTunnel
|
||||
-- 08/APR/07- add rlAutoUpdate
|
||||
-- 21-Oct-2007 Add rldot1dStpPortLoopback to rldot1dStpPortEntry
|
||||
-- 08-MAY-2007 Added rlCpuCounters
|
||||
-- 11-Mar-2008 Added rlIPv6
|
||||
-- 07-Apr-2008 added rlActionAcl for ros_vnd14's ACLs.
|
||||
-- 14-Apr-2008 added rlSafeGuard for ros_vnd14's Safeguard.
|
||||
-- 27-Aug-2008 added rlVlanTrunking for ros_vnd14's Vlan Trunking
|
||||
-- 31-Dec-2008 added rlTrafficSegmentation
|
||||
-- 05-Jan-2009 added rlIMPBFeatures
|
||||
-- 25-Mar-2009 added rlDeleteImg
|
||||
-- 02-Apr-2009 added rlCustom1BonjourService
|
||||
-- 18-Apr-2010 added rlPfcMib
|
||||
-- 30-Jan-2015 added rlLan1
|
||||
|
||||
|
||||
-- Title: RADLAN ROS
|
||||
-- Private RADLAN MIB
|
||||
-- Version: 7.46
|
||||
-- Date: 2 JAN 2007
|
||||
|
||||
IMPORTS
|
||||
|
||||
enterprises
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
Percents ::= INTEGER (0..100)
|
||||
NetNumber ::= OCTET STRING (SIZE(4))
|
||||
VlanPriority ::= INTEGER (0..7)
|
||||
|
||||
rnd MODULE-IDENTITY
|
||||
LAST-UPDATED "200701020000Z"
|
||||
ORGANIZATION "Radlan - a MARVELL company.
|
||||
Marvell Semiconductor, Inc."
|
||||
CONTACT-INFO
|
||||
"www.marvell.com"
|
||||
DESCRIPTION
|
||||
"This private MIB module defines RADLAN private MIBs."
|
||||
REVISION "200701020000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { enterprises 89 }
|
||||
|
||||
|
||||
-- Some MIB compilers require that the following 7 lines which define the path
|
||||
-- to RND MIB are commented out:
|
||||
|
||||
-- mib OBJECT IDENTIFIER ::= { mgmt 1 }
|
||||
-- directory OBJECT IDENTIFIER ::= { internet 1 }
|
||||
-- experimental OBJECT IDENTIFIER ::= { internet 3 }
|
||||
-- private OBJECT IDENTIFIER ::= { internet 4 }
|
||||
-- enterprises OBJECT IDENTIFIER ::= { private 1 }
|
||||
|
||||
-- Objects in this MIB are arranged into groups:
|
||||
--01 rndMng - Management/Action
|
||||
--02 rndDeviceParams - General parameters
|
||||
--04 rndInterface - Obsolete
|
||||
--09 rndBackup - Obsolete
|
||||
--12 rndIPX - Parameters for management of IPX router
|
||||
--16 rndFACS - Obsolete
|
||||
--20 rndCOD - Obsolete
|
||||
--22 rndBrgHub - Obsolete
|
||||
--23 rndAdapter - Obsolete
|
||||
--24 rndBootP - BootP configurgaration.
|
||||
--26 ipSpec - IP Private MIBs
|
||||
--27 virtualLan - Obsolete
|
||||
--28 rsConf - Obsolete
|
||||
--29 rsTunning - Tunning sub group
|
||||
--30 rndISDN - Obsolete
|
||||
--31 rndPPP - Obsolete
|
||||
--34 frameRelay - Obsolete
|
||||
--35 rndApplications -
|
||||
--38 rsDHCP - DHCP server configuration
|
||||
--39 radWiz - Obsolete
|
||||
--40 rsCfgUpgrade - Obsolete
|
||||
--42 rsUDP -
|
||||
--43 swInterfaces -
|
||||
--44 securityZone - Obsolete
|
||||
--45 rll3SwtchETMdl - Obsolete
|
||||
--46 rlIPmulticast -
|
||||
--47 rlFFT -
|
||||
--48 vlan -
|
||||
--49 rlRmonControl -
|
||||
--50 rlBrgMacSwitch -
|
||||
--51 rlExperience -
|
||||
--52 rlCli -
|
||||
--53 rlPhysicalDescription -
|
||||
--54 rlIfInterfaces -
|
||||
--55 rlMacMulticast -
|
||||
--56 rlGalileo -
|
||||
--57 rlpBridgeMIBObjects-
|
||||
--58 rlTelnet -
|
||||
--59 rlPolicy -
|
||||
--60 rlArpSpoofing -
|
||||
--61 rlMir -
|
||||
--62 rlIpMRouteStdMIB -
|
||||
--63 rl3sw2swTables -
|
||||
--64 rlGvrp -
|
||||
--65 rlDot3adAgg -
|
||||
--66 rlEmbWeb -
|
||||
--67 rlSwPackageVersion -
|
||||
--68 rlBroadcom -
|
||||
--69 rlMultiSessionTerminal -
|
||||
--70 rlRCli -
|
||||
--71 rlBgp -
|
||||
--72 rlAgentsCapabilitiesGroups -
|
||||
--73 rlAggregateVlan -
|
||||
--74 rlLCli -
|
||||
--75 rlGmrp -
|
||||
--76 rlDhcpCl - Dhcp client
|
||||
--77 rlStormCtrl -
|
||||
--78 rlSsh -
|
||||
--79 rlAAA -
|
||||
--80 Radius -
|
||||
--81 rlTraceRoute -
|
||||
--82 rlSyslog -
|
||||
--83 rlEnv - HardWare status indication
|
||||
--84 rlSmon -
|
||||
--85 rlSocket -
|
||||
--86 rlDigitalKeyManage -
|
||||
--87 rlCopy -
|
||||
--88 rlQosCliMib -
|
||||
--89 rlMngInf -
|
||||
--90 rlPhy -
|
||||
--91 rlJumboFrames -
|
||||
--92 rlTimeSynchronization
|
||||
--93 rlDnsCl - Dns client
|
||||
--94 rlCDB
|
||||
--95 rldot1x
|
||||
--96 rlFile
|
||||
--97 rlAAAEap - AAA for 1x
|
||||
--98 rlSNMP
|
||||
--99 rlQosServ
|
||||
--100 rlSsl
|
||||
--101 rlMacBasePrio
|
||||
--102 Wireless Access Point Private MIB
|
||||
--103 rlLocalization
|
||||
--104 rlRs232
|
||||
--105 rlNicRedundancy
|
||||
--106 rlAmap
|
||||
--107 rlStack
|
||||
--108 rlPoe
|
||||
--109 rlUPnP
|
||||
--110 rlLldp
|
||||
--111 rlOib
|
||||
--112 rlBridgeSecurity
|
||||
--113 rlDhcpSpoofing
|
||||
--114 rlBonjour
|
||||
--115 rlLinksysSmartMIB
|
||||
--116 rlBrgMulticast
|
||||
--117 rlBrgMcMngr
|
||||
--118 rlGlobalIpAddrTable
|
||||
--119 dlPrivate
|
||||
--120 rlSecuritySuiteMib
|
||||
--121 rlIntel
|
||||
--122 rlTunnel
|
||||
--126 rlGreenEthernet
|
||||
--127 rlLbd
|
||||
--128 rlErrdisableRecovery
|
||||
--129 rlIPv6
|
||||
-- ...
|
||||
--139 rlIMPBFeatures
|
||||
--140 rlSmartPorts
|
||||
--143 rlCustom1BonjourService
|
||||
--200 rlWanMib
|
||||
|
||||
-- At the end of the MIB there is a definition of all RND-specific traps.
|
||||
|
||||
rndNotifications OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION " All the rnd notifications will reside under this branch
|
||||
as specified in
|
||||
RFC2578 'Structure of Management Information Version 2 (SMIv2)' 8.5"
|
||||
::= { rnd 0 }
|
||||
|
||||
|
||||
-- rndMng group contains Management Variables for RND devices
|
||||
|
||||
rndMng OBJECT IDENTIFIER ::= { rnd 1 }
|
||||
-- see rlMng.mib
|
||||
|
||||
rndDeviceParams OBJECT IDENTIFIER ::= { rnd 2 }
|
||||
-- see RADLAN-DEVICEPARAMS-MIB.MIB
|
||||
|
||||
-- Obsolete
|
||||
-- rndInterface OBJECT IDENTIFIER ::= { rnd 4 }
|
||||
|
||||
-- Obsolete
|
||||
-- rndBackup OBJECT IDENTIFIER ::= { rnd 9 }
|
||||
|
||||
-- Obsolete
|
||||
-- rndIPX OBJECT IDENTIFIER ::= { rnd 12 }
|
||||
|
||||
-- Obsolete
|
||||
-- rndFACS OBJECT IDENTIFIER ::= { rnd 16 }
|
||||
|
||||
-- Obsolete
|
||||
-- rndCOD OBJECT IDENTIFIER ::= { rnd 20 }
|
||||
|
||||
-- Obsolete
|
||||
-- rndBrgHub OBJECT IDENTIFIER ::= { rnd 22 }
|
||||
|
||||
-- Obsolete
|
||||
-- rndAdapter OBJECT IDENTIFIER ::= { rnd 23 }
|
||||
|
||||
rndBootP OBJECT IDENTIFIER ::= { rnd 24 }
|
||||
-- see RADLAN-BOOTP-MIB.MIB
|
||||
|
||||
-- ip Specific group Addition parameters to ip group in MIB-2
|
||||
|
||||
ipSpec OBJECT IDENTIFIER ::= { rnd 26 }
|
||||
-- see rlIp.mib
|
||||
|
||||
-- Obsolete
|
||||
-- virtualLan OBJECT IDENTIFIER ::= { rnd 27 }
|
||||
|
||||
-- Obsolete
|
||||
-- rsConf OBJECT IDENTIFIER ::= { rnd 28 }
|
||||
|
||||
rsTunning OBJECT IDENTIFIER ::= { rnd 29 }
|
||||
-- see rlTuning.mib
|
||||
|
||||
-- Obsolete
|
||||
-- rndISDN OBJECT IDENTIFIER ::= { rnd 30}
|
||||
|
||||
-- Obsolete
|
||||
-- rndPPP OBJECT IDENTIFIER ::= { rnd 31 }
|
||||
|
||||
-- Obsolete
|
||||
-- frameRelay OBJECT IDENTIFIER ::= { rnd 34 }
|
||||
|
||||
rndApplications OBJECT IDENTIFIER ::= { rnd 35 }
|
||||
-- see rlApplication.mib
|
||||
|
||||
-- Obsolete
|
||||
-- rndOGCompression OBJECT IDENTIFIER ::= { rnd 36 }
|
||||
|
||||
-- Obsolete
|
||||
-- rndEthernet OBJECT IDENTIFIER ::= { rnd 37 }
|
||||
|
||||
--rsDHCP OBJECT IDENTIFIER ::= { rnd 38 }
|
||||
--see rlDhcl.mib
|
||||
|
||||
-- Obsolete
|
||||
-- radWiz OBJECT IDENTIFIER ::= { rnd 39 }
|
||||
|
||||
-- Obsolete
|
||||
-- rsCfgUpgrade OBJECT IDENTIFIER ::= { rnd 40 }
|
||||
|
||||
-- Obsolete
|
||||
--rsRMON OBJECT IDENTIFIER ::= { rnd 41 }
|
||||
|
||||
-- rsCopyPort was deleted
|
||||
-- { rsRMON 1 } reserved
|
||||
|
||||
-- rsMonitPort was deleted
|
||||
-- { rsRMON 2 } reserved
|
||||
|
||||
rsUDP OBJECT IDENTIFIER ::= { rnd 42}
|
||||
-- see rlUdp.mib
|
||||
|
||||
swInterfaces OBJECT IDENTIFIER ::= { rnd 43 }
|
||||
-- see rlInterfaces.mib
|
||||
|
||||
-- Obsolete
|
||||
-- securityZone OBJECT IDENTIFIER ::= { rnd 44 }
|
||||
|
||||
-- Obsolete
|
||||
-- rll3SwtchETMdl OBJECT IDENTIFIER ::= { rnd 45 }
|
||||
|
||||
rlIPmulticast OBJECT IDENTIFIER ::= { rnd 46 }
|
||||
|
||||
rlFFT OBJECT IDENTIFIER ::= { rnd 47 }
|
||||
|
||||
vlan OBJECT IDENTIFIER ::= { rnd 48 }
|
||||
|
||||
rlRmonControl OBJECT IDENTIFIER ::= { rnd 49}
|
||||
-- see rlRmon.mib
|
||||
|
||||
rlBrgMacSwitch OBJECT IDENTIFIER ::= { rnd 50 }
|
||||
-- see RADLAN-BRGMACSWITCH-MIB.MIB
|
||||
|
||||
rlExperience OBJECT IDENTIFIER ::= { rnd 51 }
|
||||
|
||||
rlCli OBJECT IDENTIFIER ::= { rnd 52 }
|
||||
--see RADLAN-CLI-MIB.MIB
|
||||
|
||||
-- Used for Drafts not received yet OBJECT IDENTIFIER
|
||||
|
||||
rlPhysicalDescription OBJECT IDENTIFIER ::= { rnd 53 }
|
||||
|
||||
rlIfInterfaces OBJECT IDENTIFIER ::= { rnd 54 }
|
||||
-- see rlInterfaces.mib
|
||||
|
||||
rlMacMulticast OBJECT IDENTIFIER ::= { rnd 55 }
|
||||
--see rlbrgmulticast.mib
|
||||
|
||||
rlGalileo OBJECT IDENTIFIER ::= { rnd 56 }
|
||||
|
||||
rlpBridgeMIBObjects OBJECT IDENTIFIER ::= { rnd 57 }
|
||||
--see RADLAN-BRIDGEMIBOBJECTS-MIB.MIB
|
||||
|
||||
rlTelnet OBJECT IDENTIFIER ::= { rnd 58 }
|
||||
--see RADLAN-TELNET-MIB.MIB
|
||||
|
||||
rlPolicy OBJECT IDENTIFIER ::= { rnd 59 }
|
||||
|
||||
rlArpSpoofing OBJECT IDENTIFIER ::= { rnd 60 }
|
||||
--see RADLAN-ARPSPOOFING-MIB.MIB
|
||||
|
||||
rlMir OBJECT IDENTIFIER ::= { rnd 61 }
|
||||
--see RADLAN-MIR-MIB.MIB
|
||||
|
||||
rlIpMRouteStdMIB OBJECT IDENTIFIER ::= { rnd 62 }
|
||||
|
||||
rl3sw2swTables OBJECT IDENTIFIER ::= { rnd 63 }
|
||||
--see RADLAN-3SW2SWTABLES-MIB.MIB
|
||||
|
||||
rlGvrp OBJECT IDENTIFIER ::= { rnd 64 }
|
||||
--see RADLAN-GVRP-MIB.MIB
|
||||
|
||||
rlDot3adAgg OBJECT IDENTIFIER ::= { rnd 65 }
|
||||
|
||||
rlEmbWeb OBJECT IDENTIFIER ::= { rnd 66 }
|
||||
|
||||
rlSwPackageVersion OBJECT IDENTIFIER ::= { rnd 67 }
|
||||
--see RADLAN-SWPACKAGEVERSION-MIB.MIB
|
||||
|
||||
rlBroadcom OBJECT IDENTIFIER ::= { rnd 68 }
|
||||
|
||||
rlMultiSessionTerminal OBJECT IDENTIFIER ::= { rnd 69 }
|
||||
--see RADLAN-MULTISESSIONTERMINAL-MIB.MIB
|
||||
|
||||
rlRCli OBJECT IDENTIFIER ::= { rnd 70 }
|
||||
--see RADLAN-RCLI-MIB.MIB
|
||||
|
||||
rlBgp OBJECT IDENTIFIER ::= { rnd 71 }
|
||||
|
||||
rlAgentsCapabilitiesGroups OBJECT IDENTIFIER ::= { rnd 72 }
|
||||
|
||||
rlAggregateVlan OBJECT IDENTIFIER ::= {rnd 73}
|
||||
--see RADLAN-AGGREGATEVLAN-MIB.MIB
|
||||
|
||||
-- rlLCli OBJECT IDENTIFIER ::= { rnd 74 }
|
||||
|
||||
rlGmrp OBJECT IDENTIFIER ::= { rnd 75 }
|
||||
--see RADLAN-GMRP-MIB.MIB
|
||||
|
||||
rlDhcpCl OBJECT IDENTIFIER ::= { rnd 76 }
|
||||
--see RADLAN-DHCPCL-MIB.MIB
|
||||
|
||||
------------------------------
|
||||
|
||||
rlStormCtrl OBJECT IDENTIFIER ::= { rnd 77 }
|
||||
--see RADLAN-STORMCTRL-MIB.MIB
|
||||
|
||||
rlSsh OBJECT IDENTIFIER ::= { rnd 78 }
|
||||
|
||||
rlAAA OBJECT IDENTIFIER ::= { rnd 79 }
|
||||
|
||||
rlRadius OBJECT IDENTIFIER ::= { rnd 80 }
|
||||
|
||||
-- see rlAAA.mib
|
||||
|
||||
rlTraceRoute OBJECT IDENTIFIER ::= { rnd 81 }
|
||||
--see RADLAN-TRACEROUTE-MIB.MIB
|
||||
|
||||
rlSyslog OBJECT IDENTIFIER ::= { rnd 82 }
|
||||
|
||||
rlEnv OBJECT IDENTIFIER ::= { rnd 83 }
|
||||
-- rlPhysicalDescription OBJECT IDENTIFIER ::= { rlEnv 1 }
|
||||
-- entitySensorMIB OBJECT IDENTIFIER ::= { rlEnv 2 }
|
||||
|
||||
rlSmon OBJECT IDENTIFIER ::= { rnd 84 }
|
||||
-- see RADLAN-SMON-MIB.MIB
|
||||
|
||||
rlSocket OBJECT IDENTIFIER ::= { rnd 85 }
|
||||
-- see RADLAN-SOCKET-MIB.MIB
|
||||
|
||||
rlDigitalKeyManage OBJECT IDENTIFIER ::= { rnd 86 }
|
||||
-- see RADLAN-DIGITALKEYMANAGE-MIB.MIB
|
||||
|
||||
rlCopy OBJECT IDENTIFIER ::= { rnd 87 }
|
||||
|
||||
rlQosCliMib OBJECT IDENTIFIER ::= { rnd 88 }
|
||||
|
||||
rlMngInf OBJECT IDENTIFIER ::= { rnd 89 }
|
||||
|
||||
rlPhy OBJECT IDENTIFIER ::= { rnd 90 }
|
||||
|
||||
rlJumboFrames OBJECT IDENTIFIER ::= { rnd 91 }
|
||||
-- see RADLAN-JUMBOFRAMES-MIB.MIB
|
||||
|
||||
rlTimeSynchronization OBJECT IDENTIFIER ::= { rnd 92 }
|
||||
|
||||
rlDnsCl OBJECT IDENTIFIER ::= { rnd 93 }
|
||||
|
||||
rlCDB OBJECT IDENTIFIER ::= { rnd 94 }
|
||||
-- see RADLAN-CDB-MIB.MIB
|
||||
|
||||
rldot1x OBJECT IDENTIFIER ::= { rnd 95 }
|
||||
-- see RADLAN-DOT1X-MIB.MIB
|
||||
|
||||
rlFile OBJECT IDENTIFIER ::= { rnd 96 }
|
||||
|
||||
rlAAAEap OBJECT IDENTIFIER ::= { rnd 97 }
|
||||
|
||||
rlSNMP OBJECT IDENTIFIER ::= { rnd 98 }
|
||||
|
||||
--rlQosServ OBJECT IDENTIFIER ::= { rnd 99 }
|
||||
|
||||
rlSsl OBJECT IDENTIFIER ::= { rnd 100 }
|
||||
|
||||
rlMacBasePrio OBJECT IDENTIFIER ::= { rnd 101 }
|
||||
|
||||
rlWlanAccessPoint OBJECT IDENTIFIER ::= { rnd 102 }
|
||||
|
||||
rlLocalization OBJECT IDENTIFIER ::= { rnd 103 }
|
||||
|
||||
rlRs232 OBJECT IDENTIFIER ::= { rnd 104 }
|
||||
|
||||
rlNicRedundancy OBJECT IDENTIFIER ::= { rnd 105 }
|
||||
|
||||
rlAmap OBJECT IDENTIFIER ::= { rnd 106 }
|
||||
|
||||
rlStack OBJECT IDENTIFIER ::= { rnd 107 }
|
||||
|
||||
rlPoe OBJECT IDENTIFIER ::= { rnd 108 }
|
||||
|
||||
rlUPnP OBJECT IDENTIFIER ::= { rnd 109 }
|
||||
|
||||
rlLldp OBJECT IDENTIFIER ::= { rnd 110 }
|
||||
|
||||
rlOib OBJECT IDENTIFIER ::= { rnd 111 }
|
||||
|
||||
rlBridgeSecurity OBJECT IDENTIFIER ::= { rnd 112 }
|
||||
|
||||
rlDhcpSpoofing OBJECT IDENTIFIER ::= { rnd 113 }
|
||||
|
||||
rlBonjour OBJECT IDENTIFIER ::= { rnd 114 }
|
||||
|
||||
rlLinksysSmartMIB OBJECT IDENTIFIER ::= { rnd 115 }
|
||||
|
||||
rlBrgMulticast OBJECT IDENTIFIER ::= { rnd 116 }
|
||||
|
||||
rlBrgMcMngr OBJECT IDENTIFIER ::= { rnd 117 }
|
||||
|
||||
rlGlobalIpAddrTable OBJECT IDENTIFIER ::= { rnd 118 }
|
||||
|
||||
dlPrivate OBJECT IDENTIFIER ::= { rnd 119 }
|
||||
|
||||
rlSecuritySuiteMib OBJECT IDENTIFIER ::= { rnd 120 }
|
||||
|
||||
rlIntel OBJECT IDENTIFIER ::= { rnd 121 }
|
||||
|
||||
rlTunnel OBJECT IDENTIFIER ::= { rnd 122 }
|
||||
|
||||
rlAutoUpdate OBJECT IDENTIFIER ::= { rnd 123 }
|
||||
|
||||
rlCpuCounters OBJECT IDENTIFIER ::= { rnd 124 }
|
||||
|
||||
--xxxx OBJECT IDENTIFIER ::= { rnd 125 }
|
||||
|
||||
--rlGreenEthernet OBJECT IDENTIFIER ::= { rnd 126 }
|
||||
|
||||
rlLbd OBJECT IDENTIFIER ::= { rnd 127 }
|
||||
|
||||
rlErrdisableRecovery OBJECT IDENTIFIER ::= { rnd 128 }
|
||||
|
||||
rlIPv6 OBJECT IDENTIFIER ::= { rnd 129 }
|
||||
|
||||
rlActionAcl OBJECT IDENTIFIER ::= { rnd 130 }
|
||||
|
||||
rlSafeGuard OBJECT IDENTIFIER ::= { rnd 131 }
|
||||
|
||||
rlProtectedPorts OBJECT IDENTIFIER ::= { rnd 132}
|
||||
|
||||
rlBanner OBJECT IDENTIFIER ::= { rnd 133}
|
||||
|
||||
rlGreenEth OBJECT IDENTIFIER ::= { rnd 134}
|
||||
|
||||
rlDlf OBJECT IDENTIFIER ::= { rnd 135}
|
||||
|
||||
rlVlanTrunking OBJECT IDENTIFIER ::= { rnd 136 }
|
||||
|
||||
rlCdp OBJECT IDENTIFIER ::= { rnd 137 }
|
||||
|
||||
rlTrafficSeg OBJECT IDENTIFIER ::= { rnd 138 }
|
||||
|
||||
rlImpbFeatures OBJECT IDENTIFIER ::= { rnd 139 }
|
||||
|
||||
rlSmartPorts OBJECT IDENTIFIER ::= { rnd 140 }
|
||||
|
||||
rlStatistics OBJECT IDENTIFIER ::= { rnd 141 }
|
||||
|
||||
rlDeleteImg OBJECT IDENTIFIER ::= { rnd 142 }
|
||||
|
||||
rlCustom1BonjourService OBJECT IDENTIFIER ::= { rnd 143 }
|
||||
|
||||
rlSpecialBpdu OBJECT IDENTIFIER ::= { rnd 144 }
|
||||
|
||||
rlTBIMib OBJECT IDENTIFIER ::= { rnd 145}
|
||||
|
||||
rlWeightedRandomTailDrop OBJECT IDENTIFIER ::= { rnd 146}
|
||||
|
||||
rlsFlowMib OBJECT IDENTIFIER ::= { rnd 147 }
|
||||
|
||||
rlPfcMib OBJECT IDENTIFIER ::= { rnd 148}
|
||||
|
||||
rlEee OBJECT IDENTIFIER ::= { rnd 149}
|
||||
|
||||
rlEventsMib OBJECT IDENTIFIER ::= { rnd 150}
|
||||
|
||||
rlWlanMIB OBJECT IDENTIFIER ::= { rnd 200 }
|
||||
|
||||
rlEtsMib OBJECT IDENTIFIER ::= { rnd 201 }
|
||||
|
||||
rlQcnMib OBJECT IDENTIFIER ::= { rnd 202 }
|
||||
|
||||
rlSctMib OBJECT IDENTIFIER ::= { rnd 203 }
|
||||
|
||||
rlSysmngMib OBJECT IDENTIFIER ::= { rnd 204 }
|
||||
|
||||
rlFip OBJECT IDENTIFIER ::= { rnd 205 }
|
||||
|
||||
rlDebugCapabilities OBJECT IDENTIFIER ::= { rnd 206 }
|
||||
|
||||
rlIpStdAcl OBJECT IDENTIFIER ::= { rnd 207 }
|
||||
|
||||
rlSecSd OBJECT IDENTIFIER ::= { rnd 209 }
|
||||
|
||||
rlOspf OBJECT IDENTIFIER ::= { rnd 210 }
|
||||
|
||||
rlRtRedist OBJECT IDENTIFIER ::= { rnd 211 }
|
||||
|
||||
rlIpPrefList OBJECT IDENTIFIER ::= { rnd 212 }
|
||||
|
||||
rlVoipSnoop OBJECT IDENTIFIER ::= { rnd 213 }
|
||||
|
||||
rlDhcpv6 OBJECT IDENTIFIER ::= { rnd 214}
|
||||
|
||||
rlIpv6Fhs OBJECT IDENTIFIER ::= { rnd 215}
|
||||
|
||||
rlInventoryEnt OBJECT IDENTIFIER ::= { rnd 217}
|
||||
|
||||
rlUdld OBJECT IDENTIFIER ::= { rnd 218 }
|
||||
|
||||
rlSpan OBJECT IDENTIFIER ::= { rnd 219 }
|
||||
|
||||
rlPortStat OBJECT IDENTIFIER ::= { rnd 223 }
|
||||
|
||||
rlLan1 OBJECT IDENTIFIER ::= { rnd 224 }
|
||||
|
||||
rlIgmp OBJECT IDENTIFIER ::= { rnd 225 }
|
||||
|
||||
rlRadiusServ OBJECT IDENTIFIER ::= { rnd 226 }
|
||||
|
||||
rlRouteMap OBJECT IDENTIFIER ::= { rnd 227 }
|
||||
|
||||
rlPolicyBasedRouting OBJECT IDENTIFIER ::= { rnd 228 }
|
||||
|
||||
rlSna OBJECT IDENTIFIER ::= { rnd 229 }
|
||||
|
||||
rlWBA OBJECT IDENTIFIER ::= { rnd 230 }
|
||||
|
||||
rndEndOfMibGroup OBJECT IDENTIFIER ::= { rnd 1000 }
|
||||
|
||||
-- see RADLAN-ENDOFMIB-MIB.MIB
|
||||
|
||||
END
|
||||
|
233
MIBS/eltexmes23xx/RADLAN-PHY-MIB
Normal file
233
MIBS/eltexmes23xx/RADLAN-PHY-MIB
Normal file
@ -0,0 +1,233 @@
|
||||
RADLAN-PHY-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: RADLAN PHY MIB
|
||||
-- Version: 7.38
|
||||
-- Date: 10 Sep 2004
|
||||
--
|
||||
IMPORTS
|
||||
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
|
||||
ifIndex FROM IF-MIB
|
||||
TimeStamp, DisplayString FROM SNMPv2-TC
|
||||
TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC
|
||||
rnd FROM RADLAN-MIB;
|
||||
|
||||
rlPhy MODULE-IDENTITY
|
||||
LAST-UPDATED "200209300024Z" -- September 30, 2002
|
||||
ORGANIZATION "Radlan Computer Communication Ltd."
|
||||
CONTACT-INFO
|
||||
"radlan.com"
|
||||
DESCRIPTION
|
||||
"The MIB module describes the private MIB for testing Layer1 interfaces supported
|
||||
by Radlan's software and products."
|
||||
REVISION "200209300024Z" -- September 30, 2002
|
||||
DESCRIPTION
|
||||
"Initial revision"
|
||||
REVISION "200309210024Z" -- September 21, 2003
|
||||
DESCRIPTION
|
||||
"Added MODULE-IDENTITY and TEXTUAL-CONVENTION IMPORTS."
|
||||
::= { rnd 90 }
|
||||
|
||||
|
||||
RlPhyTestType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A value indicating the test to perform."
|
||||
SYNTAX INTEGER {
|
||||
rlPhyTestTableNoTest(1),
|
||||
rlPhyTestTableCableStatus(2),
|
||||
rlPhyTestTableCableFault(3),
|
||||
rlPhyTestTableCableLength(4),
|
||||
rlPhyTestTableTransceiverTemp(5),
|
||||
rlPhyTestTableTransceiverSupply(6),
|
||||
rlPhyTestTableTxBias(7),
|
||||
rlPhyTestTableTxOutput(8),
|
||||
rlPhyTestTableRxOpticalPower(9),
|
||||
rlPhyTestTableDataReady(10),
|
||||
rlPhyTestTableLOS(11),
|
||||
rlPhyTestTableTxFault(12),
|
||||
rlPhyTestTableCableChannel1(13),
|
||||
rlPhyTestTableCableChannel2(14),
|
||||
rlPhyTestTableCableChannel3(15),
|
||||
rlPhyTestTableCableChannel4(16),
|
||||
rlPhyTestTableCablePolarity1(17),
|
||||
rlPhyTestTableCablePolarity2(18),
|
||||
rlPhyTestTableCablePolarity3(19),
|
||||
rlPhyTestTableCablePolarity4(20),
|
||||
rlPhyTestTableCablePairSkew1(21),
|
||||
rlPhyTestTableCablePairSkew2(22),
|
||||
rlPhyTestTableCablePairSkew3(23),
|
||||
rlPhyTestTableCablePairSkew4(24),
|
||||
rlPhyTestTableCableStatusFast(25),
|
||||
rlPhyTestTableSFPEepromQualified(26),
|
||||
rlPhyTestTableRxOpticalPower1(27),
|
||||
rlPhyTestTableRxOpticalPower2(28),
|
||||
rlPhyTestTableRxOpticalPower3(29),
|
||||
rlPhyTestTableTxBias1(30),
|
||||
rlPhyTestTableTxBias2(31),
|
||||
rlPhyTestTableTxBias3(32),
|
||||
rlPhyTestTableLOS1(33),
|
||||
rlPhyTestTableLOS2(34),
|
||||
rlPhyTestTableLOS3(35)
|
||||
}
|
||||
|
||||
rlPhyTest OBJECT IDENTIFIER ::= { rlPhy 1 }
|
||||
|
||||
rlPhyTestSetTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPhyTestSetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION ""
|
||||
::= { rlPhyTest 1}
|
||||
|
||||
rlPhyTestSetEntry OBJECT-TYPE
|
||||
SYNTAX RlPhyTestSetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing objects for invoking tests on an interface."
|
||||
INDEX {ifIndex }
|
||||
::= { rlPhyTestSetTable 1 }
|
||||
|
||||
RlPhyTestSetEntry ::=
|
||||
SEQUENCE {
|
||||
rlPhyTestSetType RlPhyTestType
|
||||
}
|
||||
|
||||
rlPhyTestSetType OBJECT-TYPE
|
||||
SYNTAX RlPhyTestType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A control variable used to start operator initiated interface
|
||||
tests.1 indicates that no test has been initiated. Only
|
||||
operator initiated interface tests can be set to this variable."
|
||||
::= { rlPhyTestSetEntry 1 }
|
||||
|
||||
rlPhyTestGetTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPhyTestGetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION ""
|
||||
::= { rlPhyTest 2 }
|
||||
|
||||
rlPhyTestGetEntry OBJECT-TYPE
|
||||
SYNTAX RlPhyTestGetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing results of tests on an interface."
|
||||
INDEX {ifIndex, rlPhyTestGetType}
|
||||
::= { rlPhyTestGetTable 1 }
|
||||
|
||||
RlPhyTestGetEntry ::=
|
||||
SEQUENCE {
|
||||
rlPhyTestGetType RlPhyTestType,
|
||||
rlPhyTestGetStatus INTEGER,
|
||||
rlPhyTestGetResult INTEGER,
|
||||
rlPhyTestGetUnits INTEGER,
|
||||
rlPhyTestGetAlarm INTEGER,
|
||||
rlPhyTestGetTimeStamp DisplayString
|
||||
}
|
||||
|
||||
rlPhyTestGetType OBJECT-TYPE
|
||||
SYNTAX RlPhyTestType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A control variable used to, 1 to indicate that this test can be
|
||||
done on the specified port, 2 to initiate the test whenever the
|
||||
user wishes"
|
||||
::= { rlPhyTestGetEntry 1 }
|
||||
|
||||
rlPhyTestGetStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(1), -- no test yet requested
|
||||
success(2),
|
||||
inProgress(3),
|
||||
notSupported(4),
|
||||
unAbleToRun(5), -- due to state of system
|
||||
aborted(6),
|
||||
failed(7)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object contains the status of the most recently
|
||||
requested test for operator initiated tests or the value
|
||||
none(1) if no tests have been requested since the last
|
||||
reset. For non operator initiated tests the value is always
|
||||
none(1).
|
||||
Note that this facility provides no provision for saving
|
||||
the results of one test when starting another, as could
|
||||
be required if used by multiple managers concurrently."
|
||||
::= { rlPhyTestGetEntry 2 }
|
||||
|
||||
rlPhyTestGetResult OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object holds the test result"
|
||||
::= { rlPhyTestGetEntry 3 }
|
||||
|
||||
rlPhyTestGetUnits OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
integer(1),
|
||||
boolean(2),
|
||||
downUP(3),
|
||||
reverseNormal(4),
|
||||
mdiMdix(5),
|
||||
meter(6),
|
||||
degree(7), -- Celsius
|
||||
microVolt(8),
|
||||
microOham(9),
|
||||
microAmper(10),
|
||||
microWatt(11),
|
||||
millisecond(12),
|
||||
alaskaPhyLength(13),
|
||||
alaskaPhyStatus(14),
|
||||
dbm(15),
|
||||
decidbm(16),
|
||||
milidbm(17),
|
||||
abcd(18),
|
||||
nanosecond(19)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The test result unit of measure. The units can be standard unit or special units
|
||||
that are designed for special test.
|
||||
|
||||
The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
|
||||
less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).
|
||||
|
||||
The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
|
||||
4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
|
||||
::= { rlPhyTestGetEntry 4 }
|
||||
|
||||
rlPhyTestGetAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
notRelevant(1),
|
||||
noAlarmSet(2),
|
||||
lowWarning(3),
|
||||
highWarning(4),
|
||||
lowAlarm(5),
|
||||
highAlarm(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object hold the Alarm for this Entry. only Test that have can have alarms
|
||||
use this field, other holds the Value notRelevant(1) "
|
||||
::= { rlPhyTestGetEntry 5 }
|
||||
|
||||
rlPhyTestGetTimeStamp OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time in string (formated DD-MMM-YYYY HH:MM:SS e.g
|
||||
14-Apr-2002 10:33:31)"
|
||||
::= { rlPhyTestGetEntry 6 }
|
||||
|
||||
END
|
1319
MIBS/eltexmes23xx/RADLAN-Physicaldescription-MIB
Normal file
1319
MIBS/eltexmes23xx/RADLAN-Physicaldescription-MIB
Normal file
File diff suppressed because it is too large
Load Diff
495
MIBS/eltexmes23xx/RADLAN-rndMng
Normal file
495
MIBS/eltexmes23xx/RADLAN-rndMng
Normal file
@ -0,0 +1,495 @@
|
||||
RADLAN-rndMng DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: RADLAN Management Private Extension
|
||||
-- Version: 7.45
|
||||
-- Date: 19 Dec 2006
|
||||
-- 28-Feb-2005 Added rlCpuUtilEnable
|
||||
-- 28-Feb-2005 Added rlCpuUtilDuringLastSecond
|
||||
-- 28-Feb-2005 Added rlCpuUtilDuringLastMinute
|
||||
-- 28-Feb-2005 Added rlCpuUtilDuringLast5Minutes
|
||||
-- 13-Jun-2006 Added value {none} of rndAction
|
||||
-- 20-Jun-2006 Added rlRebootDelay
|
||||
-- 19-Dec-2006 Added resetToFactoryDefaults
|
||||
-- 04-Apr-2012 Added rlScheduledReload
|
||||
-- 04-Dec-2012 Added rlSysNameTable
|
||||
|
||||
IMPORTS
|
||||
rnd FROM RADLAN-MIB
|
||||
Unsigned32,
|
||||
MODULE-IDENTITY, OBJECT-TYPE, TimeTicks FROM SNMPv2-SMI
|
||||
RowStatus, TruthValue, DisplayString,
|
||||
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
||||
InetAddressType, InetAddress FROM INET-ADDRESS-MIB
|
||||
InterfaceIndex FROM IF-MIB;
|
||||
|
||||
|
||||
rndMng MODULE-IDENTITY
|
||||
LAST-UPDATED "201212040000Z"
|
||||
ORGANIZATION "Radlan Computer Communications Ltd."
|
||||
CONTACT-INFO
|
||||
"radlan.com"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for RND general management MIB."
|
||||
REVISION "201212040000Z"
|
||||
DESCRIPTION
|
||||
"Added rlSysNameTable object."
|
||||
REVISION "201204040000Z"
|
||||
DESCRIPTION
|
||||
"Added rlScheduledReload object."
|
||||
REVISION "200902240000Z"
|
||||
DESCRIPTION
|
||||
"Added rlRunningCDBequalToStartupCDB object."
|
||||
REVISION "200710240000Z"
|
||||
DESCRIPTION
|
||||
"Added rlGroupManagement branch."
|
||||
REVISION "200606200000Z"
|
||||
DESCRIPTION
|
||||
"Added rlRebootDelay object"
|
||||
REVISION "200406010000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB."
|
||||
::= { rnd 1 }
|
||||
|
||||
|
||||
rndSysId OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identification of an RND device. The device type for each
|
||||
integer clarifies the sysObjectID in MIB - II."
|
||||
::= { rndMng 1 }
|
||||
|
||||
rndAction OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
reset(1),
|
||||
sendNetworkTab(2),
|
||||
deleteNetworkTab(3),
|
||||
sendRoutingTab(4), -- Level II
|
||||
deleteRoutingTab(5),
|
||||
sendLanTab(6),
|
||||
deleteLanTab(7),
|
||||
deleteArpTab(8),
|
||||
sendArpTab(9),
|
||||
deleteRouteTab(10), -- Level III
|
||||
sendRouteTab(11),
|
||||
backupSPFRoutingTab(12),
|
||||
backupIPRoutingTab(13),
|
||||
backupNetworkTab(14),
|
||||
backupLanTab(15),
|
||||
backupArpTab(16),
|
||||
backupIPXRipTab(17),
|
||||
backupIPXSAPTab(18),
|
||||
resetStartupCDB(19),
|
||||
eraseStartupCDB(20),
|
||||
deleteZeroHopRoutingAllocTab(21),
|
||||
slipDisconnect(22),
|
||||
deleteDynamicLanTab(23),
|
||||
eraseRunningCDB(24),
|
||||
copyStartupToRunning(25),
|
||||
none(26),
|
||||
resetToFactoryDefaults(27)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable enables the operator to perform one of the
|
||||
specified actions on the tables maintained by the network device.
|
||||
Send actions require support of proprietery File exchange
|
||||
protocol."
|
||||
::= { rndMng 2 }
|
||||
|
||||
rndFileName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING -- SIZE 256
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name of the file used internally by RND for transferring
|
||||
tables maintained by network devices, using a prorietary File
|
||||
exchange protocol."
|
||||
::= { rndMng 3 }
|
||||
|
||||
rlSnmpVersionSupported OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the snmp versions that are supported by
|
||||
this device."
|
||||
::= { rndMng 4 }
|
||||
|
||||
rlSnmpMibVersion OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the snmp support version that is supported by
|
||||
this device."
|
||||
::= { rndMng 5 }
|
||||
|
||||
rlCpuUtilEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enables measurement of the device CPU utilization.
|
||||
In order to get real values for rlCpuUtilDuringLastSecond, rlCpuUtilDuringLastMinute
|
||||
and rlCpuUtilDuringLast5Minutes, the value of this object must be true."
|
||||
DEFVAL { true }
|
||||
::= { rndMng 6 }
|
||||
|
||||
rlCpuUtilDuringLastSecond OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..101)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Percentage of the device CPU utilization during last second.
|
||||
The value 101 is a dummy value, indicating that the CPU utilization was
|
||||
not measured (since measurement is disabled or was disabled during last second)."
|
||||
::= { rndMng 7 }
|
||||
|
||||
rlCpuUtilDuringLastMinute OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..101)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Percentage of the device CPU utilization during last minute.
|
||||
The value 101 is a dummy value, indicating that the CPU utilization was
|
||||
not measured (since measurement is disabled or was disabled during last minute)."
|
||||
::= { rndMng 8 }
|
||||
|
||||
rlCpuUtilDuringLast5Minutes OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..101)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Percentage of the device CPU utilization during the last 5 minutes.
|
||||
The value 101 is a dummy value, indicating that the CPU utilization was
|
||||
not measured (since measurement is disabled or was disabled during last 5 minutes)."
|
||||
::= { rndMng 9 }
|
||||
|
||||
rlRebootDelay OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting the variable will cause the device to reboot rlRebootDelay timeticks
|
||||
from the moment this variable was set.
|
||||
If not set, the variable will return a value of 4294967295.
|
||||
If set to 4294967295, reboot action is cancelled.
|
||||
The maximum delay is set by the host parameter: reboot_delay_max"
|
||||
::= { rndMng 10 }
|
||||
|
||||
rlGroupManagement OBJECT IDENTIFIER ::= { rndMng 11 }
|
||||
|
||||
rlGroupMngQuery OBJECT-TYPE
|
||||
SYNTAX INTEGER {query(1), idle(2) }
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting value query will cause the device to query for UPNP devices on the network.
|
||||
The device will always return value idle for GET."
|
||||
::= { rlGroupManagement 1 }
|
||||
|
||||
rlGroupMngQueryPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Sets desired interval between queries for UPNP devices on the network.
|
||||
Setting 0 will result in no such query.
|
||||
Note that the actual query interval might be less than the set value
|
||||
if another application running in the device requested a shorter interval.
|
||||
Likewise setting 0 will not necessarily stop periodic queries if another
|
||||
application is still interested in periodic polling."
|
||||
DEFVAL { 0 }
|
||||
::= { rlGroupManagement 2 }
|
||||
|
||||
rlGroupMngLastUpdate OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The last time rlGroupMng MIB was updated."
|
||||
::= { rlGroupManagement 3 }
|
||||
|
||||
|
||||
rlGroupMngDevicesTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlGroupMngDeviceEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table showing the discovered devices."
|
||||
::= { rlGroupManagement 4 }
|
||||
|
||||
rlGroupMngDeviceEntry OBJECT-TYPE
|
||||
|
||||
SYNTAX RlGroupMngDeviceEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The row definition for this table."
|
||||
INDEX { rlGroupMngDeviceIdType, rlGroupMngDeviceId, rlGroupMngSubdevice }
|
||||
|
||||
::= { rlGroupMngDevicesTable 1 }
|
||||
|
||||
|
||||
RlGroupMngDeviceEntry ::= SEQUENCE {
|
||||
rlGroupMngDeviceIdType InetAddressType,
|
||||
rlGroupMngDeviceId InetAddress,
|
||||
rlGroupMngSubdevice INTEGER,
|
||||
rlGroupMngDeviceDescription DisplayString,
|
||||
rlGroupMngGroupMngEnabled TruthValue,
|
||||
rlGroupMngGroupLLDPDeviceId DisplayString,
|
||||
rlGroupMngDeviceVendor DisplayString,
|
||||
rlGroupMngDeviceAdvertisedCachingTime INTEGER,
|
||||
rlGroupMngDeviceLocationURL DisplayString,
|
||||
rlGroupMngDeviceLastSeen TimeTicks
|
||||
}
|
||||
|
||||
rlGroupMngDeviceIdType OBJECT-TYPE
|
||||
SYNTAX InetAddressType
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The IP address type of the discovered device "
|
||||
::= { rlGroupMngDeviceEntry 1 }
|
||||
|
||||
rlGroupMngDeviceId OBJECT-TYPE
|
||||
SYNTAX InetAddress
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The IP address of the discovered device "
|
||||
::= { rlGroupMngDeviceEntry 2 }
|
||||
|
||||
rlGroupMngSubdevice OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A subdevice within the rlGroupMngDeviceId. Only subdevices with greatest
|
||||
specifity will be kept (specific UUID device is more specific than basic device which is in turn
|
||||
more specific than root device. "
|
||||
::= { rlGroupMngDeviceEntry 3 }
|
||||
|
||||
rlGroupMngDeviceDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The discovery protocol description of the device."
|
||||
::= { rlGroupMngDeviceEntry 4 }
|
||||
|
||||
|
||||
rlGroupMngGroupMngEnabled OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether the device has Group Management enable."
|
||||
::= { rlGroupMngDeviceEntry 5 }
|
||||
|
||||
rlGroupMngGroupLLDPDeviceId OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The LLDP device id. If it is empty the device id is not known (either it is a non-MTS device or a non-LLDP supporting MTS device."
|
||||
::= { rlGroupMngDeviceEntry 6 }
|
||||
|
||||
rlGroupMngDeviceVendor OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The vendor of the device. If empty the vendor is not known."
|
||||
::= { rlGroupMngDeviceEntry 7 }
|
||||
|
||||
rlGroupMngDeviceAdvertisedCachingTime OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The caching time advertised by the device. If no update for this
|
||||
device has been received during this caching time the system will assume
|
||||
that the device has left the network and will therefore remove its entry
|
||||
from the table."
|
||||
::= { rlGroupMngDeviceEntry 8 }
|
||||
|
||||
rlGroupMngDeviceLocationURL OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The URL inidicating the location of the XML presenting the details of the device."
|
||||
::= { rlGroupMngDeviceEntry 9 }
|
||||
|
||||
rlGroupMngDeviceLastSeen OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of sysUpTime at the moment of last reception of an update for
|
||||
this device. "
|
||||
::= { rlGroupMngDeviceEntry 10 }
|
||||
|
||||
rlRunningCDBequalToStartupCDB OBJECT-TYPE
|
||||
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether there are changes in running CDB that were not saved in flash."
|
||||
::= { rndMng 13 }
|
||||
|
||||
rlClearMib OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Clear MIB value for scalars or tables:
|
||||
Delete all entries for tables with dynamic entries.
|
||||
Set table entries default values for table with static entries.
|
||||
Set scalar default value."
|
||||
::= { rndMng 14 }
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
-- Scheduled Reload
|
||||
-------------------------------------------------------------------------------
|
||||
rlScheduledReload OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..10))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Used for requesting a delayed reload of the device in a
|
||||
specific desired time, should be configured in one of the following formats:
|
||||
'athhmmddMM' , 'inhhhmmm' or '', setting this value to an empty string
|
||||
will result in request for cancellation of a (previously) committed system reload.
|
||||
to complete the request, the 'rlScheduledReloadCommit' must also be set to either
|
||||
TRUE (apply) or FALSE (discard) for completion of the transaction.
|
||||
failing from doing so will result in an indefinite lock of the API"
|
||||
::= { rndMng 15 }
|
||||
|
||||
rlScheduledReloadPendingDate OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..24))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Displays the most recently requested scheduled-reload due date
|
||||
in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7).
|
||||
if there is no pending/scheduled reload request, string will be empty"
|
||||
::= { rndMng 16 }
|
||||
|
||||
rlScheduledReloadApprovedDate OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..24))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Displays the most recently approved/committed scheduled-reload date
|
||||
in 'inhhhmmathhmmssddMMYYYYw' format. where 'w' stands for weekDay (1-7).
|
||||
if there is no committed scheduled-reload , string will be empty"
|
||||
::= { rndMng 17 }
|
||||
|
||||
rlScheduledReloadCommit OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"commits the pending scheduled-reload request, and completes the transaction.
|
||||
when this value is set to TRUE, the system is instructed to perform the
|
||||
requested reload operation at the requested date/time
|
||||
as was given in 'rlScheduledReload'.
|
||||
setting this value to FALSE will discard the request."
|
||||
::= { rndMng 18 }
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
-- System Name Configuration Table
|
||||
-------------------------------------------------------------------------------
|
||||
rlSysNameTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlSysNameEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Holds the current system name configuration."
|
||||
::= { rndMng 19 }
|
||||
|
||||
rlSysNameEntry OBJECT-TYPE
|
||||
SYNTAX RlSysNameEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The row definition of this table."
|
||||
INDEX { rlSysNameSource,
|
||||
rlSysNameIfIndex }
|
||||
::= { rlSysNameTable 1 }
|
||||
|
||||
RlSysNameEntry ::= SEQUENCE {
|
||||
rlSysNameSource INTEGER,
|
||||
rlSysNameIfIndex InterfaceIndex,
|
||||
rlSysNameName DisplayString (SIZE (0..255)),
|
||||
rlSysNameRowStatus RowStatus
|
||||
}
|
||||
|
||||
rlSysNameSource OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
dhcpv6(1),
|
||||
dhcpv4(2),
|
||||
static(3)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The system name source. 'static' if defined by user through CLI,
|
||||
'dhcpv6' or 'dhcpv4' if received by DHCP network protocol."
|
||||
DEFVAL { static }
|
||||
::= { rlSysNameEntry 1 }
|
||||
|
||||
rlSysNameIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The IfIndex from which the system-name configuration was received,
|
||||
for static entries, value will always be 1."
|
||||
DEFVAL { 1 }
|
||||
::= { rlSysNameEntry 2 }
|
||||
|
||||
rlSysNameName OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..255))
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An administratively-assigned name for this managed node.
|
||||
By convention, this is the node's fully-qualified domain
|
||||
name. If the name is unknown, the value is the zero-length
|
||||
string."
|
||||
::= { rlSysNameEntry 3 }
|
||||
|
||||
rlSysNameRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The row status variable, used according to
|
||||
row installation and removal conventions."
|
||||
::= { rlSysNameEntry 4 }
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
|
||||
rlErrdisableLinkFlappingCause OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable/Disable Link flapping error disable in the switch."
|
||||
::= { rndMng 20 }
|
||||
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
|
||||
END
|
||||
|