LINKSYS-PHY-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: LINKSYS PHY MIB
|
||||
-- Version: 7.38
|
||||
-- Date: 10 Sep 2004
|
||||
--
|
||||
IMPORTS
|
||||
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
|
||||
ifIndex FROM IF-MIB
|
||||
TimeStamp, DisplayString FROM SNMPv2-TC
|
||||
rnd FROM LINKSYS-MIB
|
||||
TEXTUAL-CONVENTION FROM SNMPv2-TC;
|
||||
|
||||
rlPhy MODULE-IDENTITY
|
||||
LAST-UPDATED "200209300024Z" -- September 30, 2002
|
||||
ORGANIZATION "Linksys Computer Communication Ltd."
|
||||
CONTACT-INFO
|
||||
"www.linksys.com/business/support"
|
||||
DESCRIPTION
|
||||
"The MIB module describes the private MIB for testing Layer1 interfaces supported
|
||||
by Linksys's software and products."
|
||||
REVISION "200209300024Z" -- September 30, 2002
|
||||
DESCRIPTION
|
||||
"Initial revision"
|
||||
REVISION "200309210024Z" -- September 21, 2003
|
||||
DESCRIPTION
|
||||
"Added MODULE-IDENTITY and TEXTUAL-CONVENTION IMPORTS."
|
||||
::= { rnd 90 }
|
||||
|
||||
|
||||
RlPhyTestType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A value indicating the test to perform."
|
||||
SYNTAX INTEGER {
|
||||
rlPhyTestTableNoTest(1),
|
||||
rlPhyTestTableCableStatus(2),
|
||||
rlPhyTestTableCableFault(3),
|
||||
rlPhyTestTableCableLength(4),
|
||||
rlPhyTestTableTransceiverTemp(5),
|
||||
rlPhyTestTableTransceiverSupply(6),
|
||||
rlPhyTestTableTxBias(7),
|
||||
rlPhyTestTableTxOutput(8),
|
||||
rlPhyTestTableRxOpticalPower(9),
|
||||
rlPhyTestTableDataReady(10),
|
||||
rlPhyTestTableLOS(11),
|
||||
rlPhyTestTableTxFault(12),
|
||||
rlPhyTestTableCableChannel1(13),
|
||||
rlPhyTestTableCableChannel2(14),
|
||||
rlPhyTestTableCableChannel3(15),
|
||||
rlPhyTestTableCableChannel4(16),
|
||||
rlPhyTestTableCablePolarity1(17),
|
||||
rlPhyTestTableCablePolarity2(18),
|
||||
rlPhyTestTableCablePolarity3(19),
|
||||
rlPhyTestTableCablePolarity4(20),
|
||||
rlPhyTestTableCablePairSkew1(21),
|
||||
rlPhyTestTableCablePairSkew2(22),
|
||||
rlPhyTestTableCablePairSkew3(23),
|
||||
rlPhyTestTableCablePairSkew4(24)
|
||||
}
|
||||
|
||||
rlPhyTest OBJECT IDENTIFIER ::= { rlPhy 1 }
|
||||
|
||||
rlPhyTestSetTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPhyTestSetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION ""
|
||||
::= { rlPhyTest 1}
|
||||
|
||||
rlPhyTestSetEntry OBJECT-TYPE
|
||||
SYNTAX RlPhyTestSetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing objects for invoking tests on an interface."
|
||||
INDEX {ifIndex }
|
||||
::= { rlPhyTestSetTable 1 }
|
||||
|
||||
RlPhyTestSetEntry ::=
|
||||
SEQUENCE {
|
||||
rlPhyTestSetType RlPhyTestType
|
||||
}
|
||||
|
||||
rlPhyTestSetType OBJECT-TYPE
|
||||
SYNTAX RlPhyTestType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A control variable used to start operator initiated interface
|
||||
tests.1 indicates that no test has been initiated. Only
|
||||
operator initiated interface tests can be set to this variable."
|
||||
::= { rlPhyTestSetEntry 1 }
|
||||
|
||||
rlPhyTestGetTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPhyTestGetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION ""
|
||||
::= { rlPhyTest 2 }
|
||||
|
||||
rlPhyTestGetEntry OBJECT-TYPE
|
||||
SYNTAX RlPhyTestGetEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing results of tests on an interface."
|
||||
INDEX {ifIndex, rlPhyTestGetType}
|
||||
::= { rlPhyTestGetTable 1 }
|
||||
|
||||
RlPhyTestGetEntry ::=
|
||||
SEQUENCE {
|
||||
rlPhyTestGetType RlPhyTestType,
|
||||
rlPhyTestGetStatus INTEGER,
|
||||
rlPhyTestGetResult INTEGER,
|
||||
rlPhyTestGetUnits INTEGER,
|
||||
rlPhyTestGetAlarm INTEGER,
|
||||
rlPhyTestGetTimeStamp DisplayString
|
||||
}
|
||||
|
||||
rlPhyTestGetType OBJECT-TYPE
|
||||
SYNTAX RlPhyTestType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A control variable used to, 1 to indicate that this test can be
|
||||
done on the specified port, 2 to initiate the test whenever the
|
||||
user wishes"
|
||||
::= { rlPhyTestGetEntry 1 }
|
||||
|
||||
rlPhyTestGetStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(1), -- no test yet requested
|
||||
success(2),
|
||||
inProgress(3),
|
||||
notSupported(4),
|
||||
unAbleToRun(5), -- due to state of system
|
||||
aborted(6),
|
||||
failed(7)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object contains the status of the most recently
|
||||
requested test for operator initiated tests or the value
|
||||
none(1) if no tests have been requested since the last
|
||||
reset. For non operator initiated tests the value is always
|
||||
none(1).
|
||||
Note that this facility provides no provision for saving
|
||||
the results of one test when starting another, as could
|
||||
be required if used by multiple managers concurrently."
|
||||
::= { rlPhyTestGetEntry 2 }
|
||||
|
||||
rlPhyTestGetResult OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object holds the test result"
|
||||
::= { rlPhyTestGetEntry 3 }
|
||||
|
||||
rlPhyTestGetUnits OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
integer(1),
|
||||
boolean(2),
|
||||
downUP(3),
|
||||
reverseNormal(4),
|
||||
mdiMdix(5),
|
||||
meter(6),
|
||||
degree(7), -- Celsius
|
||||
microVolt(8),
|
||||
microOham(9),
|
||||
microAmper(10),
|
||||
microWatt(11),
|
||||
millisecond(12),
|
||||
alaskaPhyLength(13),
|
||||
alaskaPhyStatus(14),
|
||||
dbm(15),
|
||||
decidbm(16),
|
||||
milidbm(17),
|
||||
abcd(18),
|
||||
nanosecond(19)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The test result unit of measure. The units can be standard unit or special units
|
||||
that are designed for special test.
|
||||
|
||||
The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
|
||||
less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).
|
||||
|
||||
The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
|
||||
4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
|
||||
::= { rlPhyTestGetEntry 4 }
|
||||
|
||||
rlPhyTestGetAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
notRelevant(1),
|
||||
noAlarmSet(2),
|
||||
lowWarning(3),
|
||||
highWarning(4),
|
||||
lowAlarm(5),
|
||||
highAlarm(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object hold the Alarm for this Entry. only Test that have can have alarms
|
||||
use this field, other holds the Value notRelevant(1) "
|
||||
::= { rlPhyTestGetEntry 5 }
|
||||
|
||||
rlPhyTestGetTimeStamp OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time in string (formated DD-MMM-YYYY HH:MM:SS e.g
|
||||
14-Apr-2002 10:33:31)"
|
||||
::= { rlPhyTestGetEntry 6 }
|
||||
|
||||
END
|