Initial commit
This commit is contained in:
886
MIBS/sagemcom/EQUIPMENT-MIB
Normal file
886
MIBS/sagemcom/EQUIPMENT-MIB
Normal file
@ -0,0 +1,886 @@
|
||||
--*******************************************************************
|
||||
--* SAGEM, IONOS *
|
||||
--*******************************************************************
|
||||
--*******************************************************************
|
||||
--
|
||||
-- Filename: equip
|
||||
--
|
||||
-- File type: .mib
|
||||
--
|
||||
-- Description: SNMP source Mib file.
|
||||
--
|
||||
-- Contains general description and operation for
|
||||
-- equipent level.
|
||||
--
|
||||
--
|
||||
-- Version: 19 11 2002
|
||||
--
|
||||
-- Date(DD MM YYYY): 15 11 2002 last update for IONOS NMS
|
||||
--
|
||||
-- Contact: D. Mobuchon, F. Bonnevialle
|
||||
--
|
||||
-- History:
|
||||
-- Version: Date: 04 08 98
|
||||
-- Version: MIB-P0-301199 Date: 30 11 1999
|
||||
-- Version: MIB-P0-05092000 Date: 05 09 2000
|
||||
-- Modification de la table des managers
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 25 04 2001
|
||||
-- Desc: * Add 7 equipment modification counters
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 14 06 2002
|
||||
-- Desc: * DisplayString is imported from SNMPv2-TC instead of RFC1213
|
||||
--
|
||||
-- Name: F.Bonnevialle
|
||||
-- Date: 15 11 2002
|
||||
-- Desc: Modification for SilverCreek Compiler
|
||||
--*******************************************************************
|
||||
--*******************************************************************
|
||||
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
||||
--*******************************************************************
|
||||
|
||||
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- MIB: EQUIPMENT-MIB
|
||||
--*******************************************************************
|
||||
EQUIPMENT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- IMPORTS
|
||||
--*******************************************************************
|
||||
|
||||
IMPORTS
|
||||
sagemDr FROM SAGEM-DR-MIB
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE,
|
||||
IpAddress,Counter32 FROM SNMPv2-SMI
|
||||
DisplayString FROM SNMPv2-TC;
|
||||
-- TRAP-TYPE FROM RFC-1215;
|
||||
|
||||
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- OBJECTS
|
||||
--*******************************************************************
|
||||
|
||||
--*******************************************************************
|
||||
|
||||
equip MODULE-IDENTITY
|
||||
LAST-UPDATED "0211150000Z"
|
||||
ORGANIZATION "SAGEM/DR Tolbiac Centre"
|
||||
CONTACT-INFO " "
|
||||
DESCRIPTION
|
||||
"
|
||||
Modification:
|
||||
Date: 15 11 2002
|
||||
Description:
|
||||
sagemDr replace sagem-dr
|
||||
NOTIFICATION-TYPE replace TRAP-TYPE
|
||||
|
||||
Modification:
|
||||
Date: 14 06 2002
|
||||
Description: Modification of Imports
|
||||
DisplayString is imported from SNMPv2-TC instead of RFC1213
|
||||
|
||||
Modification:
|
||||
Date: 20 12 1999
|
||||
Description: Modification of comments
|
||||
Modification of bugs
|
||||
|
||||
Modification:
|
||||
Date: 19 11 1999
|
||||
Name: sagem-dr, SagemBoolean
|
||||
Description: Definition of OID sagem-dr instead of sat
|
||||
Definition of data SagemBoolean instead of Boolean
|
||||
|
||||
Name: communityString
|
||||
Description: SIZE(0..20) replaced by SIZE (0..50)
|
||||
|
||||
|
||||
New Object:
|
||||
Date: 19 11 1999
|
||||
|
||||
Name: All *Manager* are new objects
|
||||
Description: Manager list that recieves the traps.
|
||||
|
||||
Name: equipCptModif
|
||||
Description: Incremental counter used to manage
|
||||
the modifications on the equipment.
|
||||
|
||||
Name: communityAcces
|
||||
Description: new names used
|
||||
iONNOS-ANM-Supervisor instead of Set ...
|
||||
|
||||
Name: trapCommunity
|
||||
Description:SIZE(0..20) replaced by SIZE (0..50)
|
||||
|
||||
Name: equipLoad
|
||||
Description: Object is simplified to an OID
|
||||
|
||||
Name: equipLoadDiagnostic
|
||||
Description: A string to help in case of problem
|
||||
|
||||
Name: transferedItemTable,transferedItem,
|
||||
TransferedItem,transferedItemIndex
|
||||
transferedItemType,transferedItemVersion
|
||||
transferedItemComments
|
||||
Description:
|
||||
These object are used to manage the download
|
||||
and upload of some part of the data; the data
|
||||
can be a part of a program, a complete program,
|
||||
or a config.
|
||||
The transferedItemType is reused in equipLocalFile
|
||||
|
||||
Name: equipStatusV2
|
||||
Description: used by IONOS ANM V2
|
||||
|
||||
"
|
||||
REVISION "9808040000Z"
|
||||
DESCRIPTION
|
||||
"
|
||||
Creation : this MIB module describes equipment level operation such as
|
||||
date and time set, restart, reset, community and trap
|
||||
management.
|
||||
"
|
||||
::= { sagemDr 107 }
|
||||
|
||||
--*******************************************************************
|
||||
|
||||
SagemBoolean ::= INTEGER { true(1), false(2) }
|
||||
IntDateTime ::= INTEGER (0..2147483647)
|
||||
Severity ::= INTEGER
|
||||
{
|
||||
nonAlarmed (1),
|
||||
minor (2),
|
||||
major (3),
|
||||
critical (4),
|
||||
warning (5),
|
||||
invNonAlarmed (6),
|
||||
invMinor(7),
|
||||
invMajor(8),
|
||||
invCritical(9),
|
||||
invWarning(10)
|
||||
}
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
equipDateTime OBJECT-TYPE
|
||||
SYNTAX IntDateTime
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this field is the date and time of the equipment.
|
||||
It is the number of seconds since 1st January 1970."
|
||||
::= { equip 1 }
|
||||
|
||||
equipLastModif OBJECT-TYPE
|
||||
SYNTAX IntDateTime
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The date and time when the equipment was last modified."
|
||||
::= { equip 2 }
|
||||
|
||||
equipWarmStart OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The equipment make a hot start if this field is set to `true'.
|
||||
This operation can only be done by the iONOSANMsupervisor
|
||||
or dIRECTACCESSsupervisor.
|
||||
The value returns to `false' after the restart."
|
||||
::= { equip 3 }
|
||||
|
||||
equipClearConf OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The equipment resets all its parameters, including those
|
||||
stored in non-volatile media storage, if this field is set
|
||||
to `true'.
|
||||
This command does not apply to mib-2 parameters, like @ip,
|
||||
routing table, etc ...
|
||||
This operation can only be done by the iONOSANMsupervisor
|
||||
or dIRECTACCESSsupervisor.
|
||||
The value returns to `false' after the reset.
|
||||
This operation is optionnal."
|
||||
::= { equip 4 }
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- Description:
|
||||
-- Community
|
||||
-- The "communityTable" is used for the habilitation.
|
||||
-- It contains a sequense of "CommunityEntry"
|
||||
-- The size for the habilitation table is 10 elements for ADR equipement.
|
||||
-- A "CommunityEntry" is a sequence:
|
||||
-- (communityIndex,communityString,communityAccess)
|
||||
-- The different kind of habilitation are:
|
||||
-- iONOSANMobserver,
|
||||
-- iONOSANMoperator,
|
||||
-- iONOSANMsupervisor,
|
||||
-- dIRECTACCESSobserver,
|
||||
-- dIRECTACCESSoperator,
|
||||
-- dIRECTACCESSsupervisor,
|
||||
-- The 4 last one are used for the "Add Drop for IP" IPA.
|
||||
-- iONOSANMclientobserver,
|
||||
-- iONOSANMclientoperator,
|
||||
-- dIRECTACCESSclientobserver,
|
||||
-- dIRECTACCESSclientoperator.
|
||||
|
||||
communityNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of community in equipment."
|
||||
::= { equip 5 }
|
||||
|
||||
communityTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CommunityEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of community in equipment."
|
||||
::= { equip 6 }
|
||||
|
||||
communityEntry OBJECT-TYPE
|
||||
SYNTAX CommunityEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular community of the equipment."
|
||||
INDEX { communityIndex }
|
||||
::= { communityTable 1 }
|
||||
|
||||
CommunityEntry ::=
|
||||
SEQUENCE {
|
||||
communityIndex INTEGER,
|
||||
communityString DisplayString,
|
||||
communityAcces INTEGER
|
||||
}
|
||||
|
||||
communityIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value which identify a particular
|
||||
community."
|
||||
::= { communityEntry 1 }
|
||||
|
||||
|
||||
communityString OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique textual string that can be used by a SNMP manager as
|
||||
community string. It can be also used as password for other
|
||||
configuration like http, not only snmp.
|
||||
The table must have at least two entries associated with
|
||||
the iONOSANMsupervisor access right (this entry is created by
|
||||
equipement at startup with value `secret') and
|
||||
dIRECTACCESSsupervisor access right (this entry is
|
||||
created by equipement at startup with value 'supervisor') .
|
||||
According to equipment implementation, it is possible to
|
||||
create other entries associed with lower rights that PDU
|
||||
community string can afford (actualy equal if
|
||||
IONOSANMsupervisor status is granted).
|
||||
If the other access rights are created at startup by the equipment,
|
||||
its must use the following values : 'private' for
|
||||
'iONOSANMoperator, 'public' for 'iONOSANMobserver',
|
||||
'operator' for dIRECTACCESSoperator, 'observer' for
|
||||
dIRECTACCESSobserver, and 'client' for the others.
|
||||
|
||||
All community string can be modified only by
|
||||
IONOSANMsupervisor.
|
||||
A dIRECTACCESS community string can be modified by
|
||||
dIRECTACCESSsupervisor.
|
||||
|
||||
The reading of a community string gives *** for all
|
||||
access rights .
|
||||
|
||||
An entry may be discarded by setting its community string to
|
||||
void string. This should not be used by the administrator or
|
||||
he could discard himself "
|
||||
|
||||
::= { communityEntry 2 }
|
||||
|
||||
|
||||
communityAcces OBJECT-TYPE
|
||||
SYNTAX INTEGER {iONOSANMobserver (1),
|
||||
iONOSANMoperator(2),
|
||||
iONOSANMsupervisor(3),
|
||||
dIRECTACCESSobserver (4),
|
||||
dIRECTACCESSoperator(5),
|
||||
dIRECTACCESSsupervisor(6),
|
||||
iONOSANMclientobserver(7),
|
||||
iONOSANMclientoperator(8),
|
||||
dIRECTACCESSclientobserver(9),
|
||||
dIRECTACCESSclientoperator(10)
|
||||
}
|
||||
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
iONOSANMsupervisor(3) access :
|
||||
allows all operations including community string
|
||||
(community string = password)
|
||||
iONOSANMoperator(2) access :
|
||||
allows all set operations except write community
|
||||
string read or write and also some special operations.
|
||||
iONOSANMobserver (1) access :
|
||||
allows only get and get_next requests.
|
||||
dIRECTACCESSsupervisor(6) access :
|
||||
allows all operations EXcluding IONOS ANM community string
|
||||
dIRECTACCESSoperator(5) access :
|
||||
allows all set operations except write community
|
||||
string read or write and also some special operations.
|
||||
dIRECTACCESSobserver (4) access :
|
||||
allows only get and get_next requests.
|
||||
iONOSANMclientoperator(8) access :
|
||||
allows only set some special operations
|
||||
iONOSANMclientobserver(7) access :
|
||||
allows only get and get_next requests for special operations
|
||||
dIRECTACCESSclientoperator(10) access :
|
||||
allows only set some special operations
|
||||
dIRECTACCESSclientobserver(9) access :
|
||||
allows only get and get_next requests for special operations
|
||||
"
|
||||
::= { communityEntry 3 }
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- Description:
|
||||
-- "trapTable": trap's receiver table
|
||||
|
||||
trapNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of trap receivers description in equipment."
|
||||
::= { equip 7 }
|
||||
|
||||
trapTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF TrapEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of trap receivers in equipment."
|
||||
::= { equip 8 }
|
||||
|
||||
trapEntry OBJECT-TYPE
|
||||
SYNTAX TrapEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular trap of the equipment."
|
||||
INDEX { trapIndex }
|
||||
::= { trapTable 1 }
|
||||
|
||||
TrapEntry ::=
|
||||
SEQUENCE {
|
||||
trapIndex INTEGER,
|
||||
trapDestination IpAddress,
|
||||
trapCommunity DisplayString
|
||||
}
|
||||
|
||||
trapIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value which identify a particular
|
||||
trap receiver.
|
||||
The value of index is a constant assigned to an entry at
|
||||
equipment design time. "
|
||||
::= { trapEntry 1 }
|
||||
|
||||
trapDestination OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The ip address to which the equipment will send the traps.
|
||||
Note that the value must be unique along this table.
|
||||
An entry may be discarded by setting the IP address to 0.0.0.0
|
||||
"
|
||||
::= { trapEntry 2 }
|
||||
|
||||
|
||||
trapCommunity OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
-- It is better to use a size value lower than 10.
|
||||
-- The size value 50 is used for the BMX
|
||||
"The community string to use when a trap is sent to
|
||||
this address. "
|
||||
::= { trapEntry 3 }
|
||||
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
|
||||
-- Description:
|
||||
-- Up and download for the software and configuration
|
||||
--
|
||||
equipLoad OBJECT IDENTIFIER ::= { equip 9 }
|
||||
|
||||
equipLocalFile OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The file path suitable for the equipment."
|
||||
::= { equipLoad 1 }
|
||||
|
||||
equipServerAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The ip adress of tftp serveur from which is read/write
|
||||
the file `equipRemoteFile'."
|
||||
::= { equipLoad 2 }
|
||||
|
||||
equipRemoteFile OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The file path to be loaded on/from the equipement."
|
||||
::= { equipLoad 3 }
|
||||
|
||||
equipDirection OBJECT-TYPE
|
||||
SYNTAX INTEGER { download (0), upload(1)
|
||||
, backupDownload (2), switching (3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This field selects the direction of data stream.
|
||||
When it is set to `backupDownload', only the transfert is done.
|
||||
When it is set to `download' the transfert is done and then the
|
||||
information transfert is switched in the operational state.
|
||||
When it is set to `switching', there is no transfert;
|
||||
there is only a switching. "
|
||||
::= { equipLoad 4 }
|
||||
|
||||
equipLoadProceed OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
This entry is use to start (set to `true') loading a file
|
||||
on/from a equipment which has a tftp client.
|
||||
The value of the field remains to `true' until load is
|
||||
completed or has been aborted.
|
||||
This operation can only be done by the iONOSANMsupervisor
|
||||
or dIRECTACCESSsupervisor.
|
||||
It may be possible to abort the loading by setting it
|
||||
to false.
|
||||
After the switching of a new configuration, the equipment
|
||||
must increase the value of the variable 'equipCptModif'
|
||||
"
|
||||
::= { equipLoad 5 }
|
||||
|
||||
equipLoadDiagnostic OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A string used to help in case of trouble."
|
||||
::= { equipLoad 6 }
|
||||
|
||||
equipLoadProtocole OBJECT-TYPE
|
||||
SYNTAX INTEGER { ftp (1), tftp (2),
|
||||
http (3), telnet (4)}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Protocole used by the equipment for the download"
|
||||
::= { equipLoad 7 }
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- Description:
|
||||
-- Delayed up and download for the software and configuration
|
||||
--
|
||||
-- equipLoadState OBJECT-TYPE
|
||||
-- SYNTAX INTEGER { delayedLoad (1), loadRunning (2),
|
||||
-- delayedSwitching (3), switchingRunning (4),
|
||||
-- loadOK (5), loadNOK (6) ,aborted (7)}
|
||||
-- MAX-ACCESS read-only
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "This field indicates the status of the current load processes valided
|
||||
-- by 'equipLoadProceed'.
|
||||
-- Remark : a download includes a data transfer (load) from the
|
||||
-- server to the equipment and a switching for using the data or the
|
||||
-- software transfered . A upload includes only a data transfer from
|
||||
-- the equipment to the server
|
||||
-- It's optional for the equipment which doesn't realise delayed download "
|
||||
-- ::= { equipLoad 8 }
|
||||
--
|
||||
-- equipLoadDateTime OBJECT-TYPE
|
||||
-- SYNTAX IntDateTime
|
||||
-- MAX-ACCESS read-write
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "The value of this field is the date and time of the equipment
|
||||
-- at which the load processes valided by
|
||||
-- 'equipLoadProceed' must begin .
|
||||
-- If this value if equal at 0 or < at the current
|
||||
-- time, the load starts immediately.
|
||||
-- It is the number of seconds since 1st January 1970."
|
||||
-- ::= { equipLoad 9 }
|
||||
--
|
||||
-- equipSwitchingDateTime OBJECT-TYPE
|
||||
-- SYNTAX IntDateTime
|
||||
-- MAX-ACCESS read-write
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "
|
||||
-- The value of this field is the date and time of the equipment
|
||||
-- at which the switching processes valided by
|
||||
-- 'equipLoadProceed' must begin .If this value if equal at
|
||||
-- 0 or < at the current time, the switching starts immediately
|
||||
-- (if there isn't load)or immediately after the load (if there is a load).
|
||||
-- It is the number of seconds since 1st January 1970.
|
||||
-- After the switching of a new configuration, the equipment
|
||||
-- must increase the value of the variable 'equipCptModif'
|
||||
-- "
|
||||
-- ::= { equipLoad 10 }
|
||||
--
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- Description:
|
||||
-- These object are used to manage the download
|
||||
-- and upload of some part of the data; the data
|
||||
-- can be a part of a program, a complete program,
|
||||
-- or a config.
|
||||
--
|
||||
-- The transferedItemType can be:
|
||||
-- inactive programName
|
||||
-- active programName
|
||||
-- inactive"Config"
|
||||
-- active"Config"
|
||||
-- ALL Program
|
||||
-- ALL
|
||||
--
|
||||
-- The transferedItemType is reused in equipLocalFile
|
||||
|
||||
|
||||
transferedItemTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF TransferedItemEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of uploaded or downloaded Item from the
|
||||
equipment."
|
||||
::= { equip 30 }
|
||||
|
||||
transferedItemEntry OBJECT-TYPE
|
||||
SYNTAX TransferedItemEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular Item transferd from/to the equipment."
|
||||
INDEX { transferedItemIndex }
|
||||
::= { transferedItemTable 1 }
|
||||
|
||||
TransferedItemEntry ::=
|
||||
SEQUENCE {
|
||||
transferedItemIndex INTEGER,
|
||||
transferedItemType DisplayString,
|
||||
transferedItemVersion DisplayString,
|
||||
transferedItemComment DisplayString
|
||||
}
|
||||
|
||||
transferedItemIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { transferedItemEntry 1 }
|
||||
|
||||
transferedItemType OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"used to know what kind of data to transferate,
|
||||
mainly programName or config"
|
||||
::= { transferedItemEntry 2 }
|
||||
|
||||
transferedItemVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"for a program, return the software version;
|
||||
for a config return the associated software version"
|
||||
::= { transferedItemEntry 3 }
|
||||
|
||||
transferedItemComment OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"give additional information about the tranfered data"
|
||||
::= { transferedItemEntry 4 }
|
||||
|
||||
--*******************************************************************
|
||||
-- Description:
|
||||
|
||||
equipStatus OBJECT-TYPE
|
||||
SYNTAX Severity
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This field summerizes the status of all equipment objects
|
||||
(port, card, ...)
|
||||
This variable is polled by IONOS ANM V1
|
||||
The 'equipmentStatusTrap' is sent after a GET on this variable.
|
||||
equipStatus and equipStatusTrap are only used with V1.
|
||||
"
|
||||
::= { equip 10 }
|
||||
|
||||
equipStatusV2 OBJECT-TYPE
|
||||
SYNTAX Severity
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Replace equipStatus for the v2. For the v1, equipStatus
|
||||
in EQUIPMENT-MIB send a trap after been polled;
|
||||
For the v2, equipStatus is polled."
|
||||
::= { equip 11 }
|
||||
|
||||
--*******************************************************************
|
||||
--* modification counters
|
||||
--*******************************************************************
|
||||
-- Description:
|
||||
-- "equipCptModif":
|
||||
-- Incremental counter used to manage the modifications
|
||||
-- on the equipment.
|
||||
-- Warning:
|
||||
-- Replace equipLastModif for the new equipment ADR155c and
|
||||
-- the next generation of equipment.
|
||||
|
||||
equipCptModif OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter for all equipments modifications. It represents
|
||||
the sum of the 7 other counters"
|
||||
::= { equip 12 }
|
||||
|
||||
-- Modification counters
|
||||
cptModif OBJECT IDENTIFIER ::= { equip 14 }
|
||||
|
||||
cptSNC OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter version for the SNC modifications."
|
||||
::= { cptModif 1 }
|
||||
|
||||
|
||||
cptCnx OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter version for the Connexion modifications."
|
||||
::= { cptModif 2 }
|
||||
|
||||
cptMSP OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter version for the MSP modifications."
|
||||
::= { cptModif 3 }
|
||||
|
||||
cptMsSpring OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter version for the MS-SPRING modifications."
|
||||
::= { cptModif 4 }
|
||||
|
||||
cptSynchro OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter version for the Synchro modifications."
|
||||
::= { cptModif 5 }
|
||||
|
||||
cptMngt OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter version for the MNGT modifications (mngt list, password, trap, ...)."
|
||||
::= { cptModif 6 }
|
||||
|
||||
cptNet OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The counter version for the Network modifications."
|
||||
::= { cptModif 7 }
|
||||
|
||||
|
||||
-- equipConfSaveStatus OBJECT-TYPE
|
||||
-- SYNTAX SagemBoolean
|
||||
-- MAX-ACCESS read-only
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "If 'true', this variable indicates that all configuration
|
||||
-- modifications are saved in flash memory.
|
||||
-- If false, this variable indicates that configuration
|
||||
-- modifications are not saved in flash memory. "
|
||||
-- ::= { equip 13 }
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
--
|
||||
-- Description:
|
||||
-- ACCESS TABLE FILTER
|
||||
-- The table is a access filter table that ckeck the IP address of
|
||||
-- the SNMP managers.
|
||||
|
||||
|
||||
equipManagerNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of manager = number of IP addresses in the table"
|
||||
::= { equip 20 }
|
||||
|
||||
equipManagerTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EquipManagerEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table containing Ip Addresses and maximum authorized level"
|
||||
::= { equip 21 }
|
||||
|
||||
equipManagerEntry OBJECT-TYPE
|
||||
SYNTAX EquipManagerEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Entry containing IP addresses of managers allowed in R/W."
|
||||
INDEX {equipManagerIndex}
|
||||
::= {equipManagerTable 1}
|
||||
|
||||
EquipManagerEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
equipManagerIndex INTEGER,
|
||||
equipManagerAddress IpAddress,
|
||||
equipManagerADM SagemBoolean,
|
||||
equipManagerOPR SagemBoolean,
|
||||
equipManagerOBS SagemBoolean
|
||||
}
|
||||
|
||||
equipManagerIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Index of equipManagerTable
|
||||
There's only 10 values in this table"
|
||||
::= {equipManagerEntry 1}
|
||||
|
||||
equipManagerAddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The IP address of one of the allowed managers.
|
||||
If the table contains only address values which are equal
|
||||
to 0.0.0.0, no access filter are done.
|
||||
Write the IP address 0.0.0.0 to remove a manager.
|
||||
This operation can only be done by the iONOSANMsupervisor.
|
||||
"
|
||||
::= {equipManagerEntry 2}
|
||||
|
||||
equipManagerADM OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If 'true', this variable indicates that the manager defined by
|
||||
its address can have the Supervisor rigth as maximum level
|
||||
The value 'false' is set by the equipment when another level
|
||||
is choosen"
|
||||
::= {equipManagerEntry 3}
|
||||
|
||||
equipManagerOPR OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If 'true', this variable indicates that the manager defined by
|
||||
its address can have the Operator rigth as maximum level
|
||||
The value 'false' is set by the equipment when another level
|
||||
is choosen"
|
||||
::= {equipManagerEntry 4}
|
||||
|
||||
equipManagerOBS OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If 'true', this variable indicates that the manager defined by
|
||||
its address can have the Observer rigth as maximum level
|
||||
The value 'false' is set by the equipment when another level
|
||||
is choosen"
|
||||
::= {equipManagerEntry 5}
|
||||
|
||||
--*******************************************************************
|
||||
-- Warning: This Trap is only used for V1
|
||||
-- equipStatusTrap TRAP-TYPE
|
||||
-- ENTERPRISE equip
|
||||
-- VARIABLES { equipStatus }
|
||||
-- DESCRIPTION
|
||||
-- "This trap indicates the alarm status of the equipment.
|
||||
-- Only sent with IONOS ANM V1"
|
||||
-- ::= 1
|
||||
|
||||
equipTraps OBJECT IDENTIFIER ::= { equip 0 }
|
||||
|
||||
equipStatusTrap NOTIFICATION-TYPE
|
||||
OBJECTS { equipStatus }
|
||||
STATUS current
|
||||
DESCRIPTION "This trap indicates the alarm status of the equipment.
|
||||
Only sent with IONOS ANM V1"
|
||||
REFERENCE ""
|
||||
::= { equipTraps 1 }
|
||||
END
|
Reference in New Issue