TPLINK-SYSINFO-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
TimeStamp
|
||||
FROM SNMPv2-TC
|
||||
OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
tplinkMgmt
|
||||
FROM TPLINK-MIB
|
||||
ifIndex
|
||||
FROM RFC1213-MIB;
|
||||
|
||||
tplinkSysInfoMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201211290000Z"
|
||||
ORGANIZATION "TP-LINK"
|
||||
CONTACT-INFO "www.tplink.com"
|
||||
DESCRIPTION
|
||||
"This MIB module contain a collection of managed objects
|
||||
that get infomation of the system."
|
||||
|
||||
REVISION "201211290000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
::= { tplinkMgmt 1 }
|
||||
|
||||
tplinkSysInfoMIBObjects OBJECT IDENTIFIER ::= {tplinkSysInfoMIB 1}
|
||||
tplinkSysInfoNotifications OBJECT IDENTIFIER ::= {tplinkSysInfoMIB 2}
|
||||
|
||||
|
||||
tpSysInfoDescription OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual description of the entity. This value
|
||||
should include the full name and version
|
||||
identification of the system's hardware type,
|
||||
software operating-system, and networking
|
||||
software. It is current that this only contain
|
||||
printable ASCII characters."
|
||||
::= { tplinkSysInfoMIBObjects 1 }
|
||||
|
||||
tpSysInfoHostName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An administratively-assigned name for this
|
||||
managed node. By convention, this is the node's
|
||||
fully-qualified domain name.range:17 byte."
|
||||
::= { tplinkSysInfoMIBObjects 2 }
|
||||
|
||||
tpSysInfoLocation OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The physical location of this node (e.g.,
|
||||
`telephone closet, 3rd floor'),range:32 byte."
|
||||
::= { tplinkSysInfoMIBObjects 3 }
|
||||
|
||||
tpSysInfoContact OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The textual identification of the contact person
|
||||
for this managed node, together with information
|
||||
on how to contact this person.range:32 byte."
|
||||
::= { tplinkSysInfoMIBObjects 4 }
|
||||
|
||||
tpSysInfoHwVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The hardWare version of the product."
|
||||
::= { tplinkSysInfoMIBObjects 5 }
|
||||
|
||||
tpSysInfoSwVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The softWare version of the product."
|
||||
::= { tplinkSysInfoMIBObjects 6 }
|
||||
|
||||
tpSysInfoMacAddr OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MAC address of the product."
|
||||
::= { tplinkSysInfoMIBObjects 7 }
|
||||
|
||||
tpSysInfoSerialNum OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Serial number of the product."
|
||||
::= { tplinkSysInfoMIBObjects 8 }
|
||||
|
||||
tpSysInfoUpTime OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time (in hundredths of a second) since the
|
||||
network management portion of the system was last
|
||||
re-initialized."
|
||||
::= { tplinkSysInfoMIBObjects 9 }
|
||||
|
||||
tpSysInfoSerialPort OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
9600(0), --config the baud rate as 9600
|
||||
19200(1), --config the baud rate as 19200
|
||||
38400(2), --config the baud rate as 38400
|
||||
57600(3), --config the baud rate as 57600
|
||||
115200(4) --config the baud rate as 115200
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"config the baud rate of the system"
|
||||
::= { tplinkSysInfoMIBObjects 10}
|
||||
|
||||
tpSysInfoPortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF TPSYSINFOPORTENTRY
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Port Utilization."
|
||||
::= { tplinkSysInfoMIBObjects 11 }
|
||||
|
||||
tpSysInfoPortEntry OBJECT-TYPE
|
||||
SYNTAX TPSYSINFOPORTENTRY
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry contains of the information of port Utilization."
|
||||
INDEX { ifIndex }
|
||||
::= { tpSysInfoPortTable 1 }
|
||||
|
||||
TPSYSINFOPORTENTRY ::=
|
||||
SEQUENCE {
|
||||
tpSysInfoPortRxUtilization
|
||||
OCTET STRING,
|
||||
tpSysInfoPortTxUtilization
|
||||
OCTET STRING
|
||||
}
|
||||
|
||||
tpSysInfoPortRxUtilization OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Displays the port Tx Utilization."
|
||||
::= { tpSysInfoPortEntry 1 }
|
||||
|
||||
tpSysInfoPortTxUtilization OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Displays the port Tx Utilization."
|
||||
::= { tpSysInfoPortEntry 2 }
|
||||
|
||||
tpSysInfoLed OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
off(0), --LED off
|
||||
on(1), --LED on
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Config the switch LED status."
|
||||
::= { tplinkSysInfoMIBObjects 12}
|
||||
|
||||
END
|