@ -0,0 +1,121 @@
|
||||
-- *****************************************************************
|
||||
-- TN-FRA-MIB.my : TN Fault Relay Alarm MIB
|
||||
--
|
||||
-- Copyright (c) 2012 by Transition Networks, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
--
|
||||
|
||||
TN-FRA-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP FROM SNMPv2-CONF
|
||||
entPhysicalIndex FROM ENTITY-MIB
|
||||
ifIndex FROM IF-MIB
|
||||
tnProducts FROM TRANSITION-SMI;
|
||||
|
||||
tnFraMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201206251030Z"
|
||||
ORGANIZATION "Transition Networks, Inc."
|
||||
CONTACT-INFO
|
||||
"Transition Networks
|
||||
Technical Support
|
||||
|
||||
10900 Red Circle Drive
|
||||
Minnetonka, MN 55343 USA
|
||||
Tel: +1-800-526-9267
|
||||
|
||||
E-mail: techsupport@transition.com"
|
||||
DESCRIPTION
|
||||
"The mib module for managing all transition products with FRA(Fault relay alarm)"
|
||||
REVISION "201206250000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
::= { tnProducts 21 }
|
||||
|
||||
tnFraObjects OBJECT IDENTIFIER
|
||||
::= { tnFraMIB 1 }
|
||||
|
||||
tnFraMgmt OBJECT IDENTIFIER ::= { tnFraObjects 1 }
|
||||
|
||||
tnFraRelayAlarmState OBJECT-TYPE
|
||||
SYNTAX INTEGER {normal(1),negated(2)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Change the state of the relay when an alarm condition is active
|
||||
Normal (1): Relay is activated on alarm
|
||||
Negated(2): Relay is de-activated on alarm
|
||||
"
|
||||
::= { tnFraMgmt 1 }
|
||||
|
||||
tnFraPowerSupplyTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF TnFraPowerSupplyEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table is used for configuring fault relay status of the powersupply modules"
|
||||
::= { tnFraMgmt 2 }
|
||||
|
||||
tnFraPowerSupplyEntry OBJECT-TYPE
|
||||
SYNTAX TnFraPowerSupplyEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This entry contains configuration element of tnFraPowerSupplyTable"
|
||||
INDEX { entPhysicalIndex }
|
||||
::= { tnFraPowerSupplyTable 1 }
|
||||
|
||||
TnFraPowerSupplyEntry ::= SEQUENCE {
|
||||
tnFraPowerSupplyState INTEGER
|
||||
}
|
||||
|
||||
tnFraPowerSupplyState OBJECT-TYPE
|
||||
SYNTAX INTEGER { enable(1),disable(2)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trigger fault relay alarm while monitored power supply is not present
|
||||
Enabled(1) : Enable fault relay alarm.
|
||||
Disabled(2): Disable fault relay alarm.
|
||||
"
|
||||
::= { tnFraPowerSupplyEntry 1 }
|
||||
|
||||
tnFraLinkTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF TnFraLinkEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" This table is used for configuring fault relay status of the each port
|
||||
"
|
||||
::= { tnFraMgmt 3 }
|
||||
|
||||
tnFraLinkEntry OBJECT-TYPE
|
||||
SYNTAX TnFraLinkEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The entry list the tnFraLinkState priority of each port
|
||||
"
|
||||
INDEX { ifIndex }
|
||||
::= { tnFraLinkTable 1 }
|
||||
|
||||
TnFraLinkEntry ::= SEQUENCE {
|
||||
tnFraLinkState INTEGER
|
||||
}
|
||||
tnFraLinkState OBJECT-TYPE
|
||||
SYNTAX INTEGER { enable(1),disable(2)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trigger fault relay alarm while monitored Port is down
|
||||
Enabled(1) : Enable fault relay alarm of the link.
|
||||
Disabled(2): Disable fault relay alarm of the link.
|
||||
"
|
||||
::= { tnFraLinkEntry 1}
|
||||
END
|
||||
|