352 lines
		
	
	
		
			12 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			352 lines
		
	
	
		
			12 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
CM-REDUNDANCY-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
    MODULE-COMPLIANCE, OBJECT-GROUP
 | 
						|
             FROM SNMPv2-CONF
 | 
						|
    MODULE-IDENTITY, OBJECT-TYPE, Counter32, TimeTicks, Integer32
 | 
						|
             FROM SNMPv2-SMI
 | 
						|
    DisplayString, TruthValue, RowStatus, StorageType, VariablePointer,
 | 
						|
    TEXTUAL-CONVENTION
 | 
						|
             FROM SNMPv2-TC
 | 
						|
    fsp150cm
 | 
						|
             FROM  ADVA-MIB    
 | 
						|
    PhysicalIndex 
 | 
						|
             FROM ENTITY-MIB
 | 
						|
    neIndex, CardType
 | 
						|
             FROM CM-ENTITY-MIB;
 | 
						|
             
 | 
						|
cmRedundancyMIB MODULE-IDENTITY
 | 
						|
    LAST-UPDATED    "200902240000Z"
 | 
						|
    ORGANIZATION    "ADVA Optical Networking"
 | 
						|
    CONTACT-INFO
 | 
						|
            "        Raghav Trivedi
 | 
						|
                     ADVA Optical Networking, Inc.
 | 
						|
                Tel: +1 972 759-1239
 | 
						|
             E-mail: rtrivedi@advaoptical.com
 | 
						|
             Postal: 2301 N. Greenville Ave. #300
 | 
						|
                     Richardson, TX USA 75082"
 | 
						|
    DESCRIPTION
 | 
						|
            "This module defines the Redundancy MIB definitions used by 
 | 
						|
             the FSP150CM product line.  
 | 
						|
             Copyright (C) ADVA Optical Networking."
 | 
						|
    REVISION        "200902240000Z"
 | 
						|
    DESCRIPTION
 | 
						|
            "Notes from release 200902240000Z,
 | 
						|
             (1)MIB version ready for release FSP150CM 5.1." 
 | 
						|
    ::= {fsp150cm 15}    
 | 
						|
 | 
						|
-- 
 | 
						|
-- OID definitions
 | 
						|
-- 
 | 
						|
cmRedundancyObjects       OBJECT IDENTIFIER ::= {cmRedundancyMIB 1}
 | 
						|
cmRedundancyNotifications OBJECT IDENTIFIER ::= {cmRedundancyMIB 2}
 | 
						|
cmRedundancyConformance   OBJECT IDENTIFIER ::= {cmRedundancyMIB 3}
 | 
						|
 | 
						|
-- 
 | 
						|
-- Textual Conventions 
 | 
						|
-- 
 | 
						|
CmRedundancyArch ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for Redundancy Architecture.
 | 
						|
             loadbalance,
 | 
						|
             activestandby"
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   loadbalance (1),
 | 
						|
                   activestandby (2)
 | 
						|
                 }
 | 
						|
 | 
						|
CmRedundancyStandbyMode ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for Redundancy Mode.
 | 
						|
                                                                                       
 | 
						|
         coldStandby(1)     
 | 
						|
         
 | 
						|
           A method of redundancy in which the secondary (i.e., backup) system is
 | 
						|
            only called upon when the primary system fails. The system on cold standby
 | 
						|
             receives scheduled data backups, but less frequently than a warm standby. 
 | 
						|
 | 
						|
         warmStandby(2)  
 | 
						|
         
 | 
						|
           A method of redundancy in which the secondary (i.e., backup) system runs 
 | 
						|
           in the background of the primary system. Data is mirrored to the secondary
 | 
						|
            server at regular intervals, which means that there are times when both 
 | 
						|
            servers do not contain the exact same data..
 | 
						|
 | 
						|
         hotStandby(3)
 | 
						|
 | 
						|
           A method of redundancy in which the primary and secondary (i.e., backup)
 | 
						|
            systems run simultaneously. The data is mirrored to the secondary server
 | 
						|
             in real time so that both systems contain identical information. 
 | 
						|
        "
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   cold (1),
 | 
						|
                   warm (2),
 | 
						|
                   hot (3)
 | 
						|
                 }
 | 
						|
 | 
						|
CmRedundancyState ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for Redundancy State."
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   disabled (1),                   
 | 
						|
                   enabled (2)
 | 
						|
                 }
 | 
						|
CmRedundancySyncStatus ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for synchronization status."
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   none (1),                   
 | 
						|
                   out-of-synchronize (2),                   
 | 
						|
                   bulk-synchronize (3),
 | 
						|
                   incremental-synchronize (4)
 | 
						|
                 }
 | 
						|
 | 
						|
 | 
						|
CmRedundancySwitchOverReason ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for Redundancy Last Switch Over Reason."
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   unknown (1),
 | 
						|
                   latestUpdatedData (2),
 | 
						|
                   userTrigger (3),
 | 
						|
                   cardReset (4),
 | 
						|
                   cardRemoval (5),
 | 
						|
                   softwareFailure (6),
 | 
						|
                   hardwareFailure (7)
 | 
						|
                 }
 | 
						|
 | 
						|
CmRedundancySyncMode ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for Redundancy Synchronization Mode.
 | 
						|
             automatically  - Active card automatically propagates config data to its peer             
 | 
						|
             manually  - User needs to manually copy config data to standby card and apply it.             
 | 
						|
             "
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   automatically (1),
 | 
						|
                   manually(2)
 | 
						|
                 }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
CmRedundancyAction ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for User initiated Redundancy Switch Action.
 | 
						|
             force   - Force Switch from Active Card              
 | 
						|
             manual  - Manual Switch from Active Card
 | 
						|
             releasefore - Release Force switch from Active Card             
 | 
						|
             "
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   notApplicable (0), 
 | 
						|
                   force (1), 
 | 
						|
                   manual (2),
 | 
						|
                   releaseforce (3)
 | 
						|
                 }
 | 
						|
 | 
						|
CmRedundancyUnitState ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION
 | 
						|
        "Enumerations for Redundancy Unit State.
 | 
						|
             none   - no state              
 | 
						|
             normal  - normal state
 | 
						|
             maintenance - maintenance state
 | 
						|
             faultisolation - faultisolation        
 | 
						|
             "
 | 
						|
    SYNTAX       INTEGER {
 | 
						|
                   none (1), 
 | 
						|
                   normal (2), 
 | 
						|
                   maintenance(3),
 | 
						|
                   faultisolation(4),
 | 
						|
                   lock(5),
 | 
						|
                   extracted(6), 
 | 
						|
                   init(7),                    
 | 
						|
                   stanbdby(8)                 
 | 
						|
                 }
 | 
						|
                 
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- Entity Redundancy Group Table 
 | 
						|
--
 | 
						|
cmRedundancyGroupTable OBJECT-TYPE
 | 
						|
    SYNTAX     SEQUENCE OF CmRedundancyGroupEntry
 | 
						|
    MAX-ACCESS not-accessible
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "A list of entries corresponding to the Redundancy Groups.
 | 
						|
             "
 | 
						|
    ::= { cmRedundancyObjects 1 }
 | 
						|
 | 
						|
cmRedundancyGroupEntry OBJECT-TYPE
 | 
						|
    SYNTAX     CmRedundancyGroupEntry
 | 
						|
    MAX-ACCESS not-accessible
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
            "An entry containing information applicable to a particular
 | 
						|
             Redundancy Group."
 | 
						|
    INDEX { neIndex, cmRedundancyGroupIndex }
 | 
						|
    ::= { cmRedundancyGroupTable 1 }
 | 
						|
 | 
						|
CmRedundancyGroupEntry ::= SEQUENCE {
 | 
						|
    cmRedundancyGroupIndex                    Integer32,
 | 
						|
    cmRedundancyGroupUserLabel                DisplayString,
 | 
						|
    cmRedundancyGroupType                     CardType,
 | 
						|
    cmRedundancyGroupSyncEnabled              TruthValue,
 | 
						|
    cmRedundancyGroupActiveCard               VariablePointer,
 | 
						|
    cmRedundancyGroupActiveCardState          CmRedundancyUnitState,
 | 
						|
    cmRedundancyGroupStandbyCard              VariablePointer,
 | 
						|
    cmRedundancyGroupStandbyCardState         CmRedundancyUnitState,
 | 
						|
    cmRedundancyGroupLastSwitchOverTime       TimeTicks,
 | 
						|
    cmRedundancyGroupLastSwitchOverReason     CmRedundancySwitchOverReason,
 | 
						|
    cmRedundancyGroupState                    CmRedundancyState,
 | 
						|
    cmRedundancyGroupSyncStatus               CmRedundancySyncStatus,
 | 
						|
    cmRedundancyGroupAction                   CmRedundancyAction
 | 
						|
}
 | 
						|
 | 
						|
cmRedundancyGroupIndex OBJECT-TYPE
 | 
						|
    SYNTAX     Integer32
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "Unique index value associated with the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 1 }
 | 
						|
 | 
						|
cmRedundancyGroupUserLabel OBJECT-TYPE
 | 
						|
    SYNTAX     DisplayString (SIZE (0..64))
 | 
						|
    MAX-ACCESS read-create
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "User Label associated with the Reduandancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 2 }
 | 
						|
 | 
						|
cmRedundancyGroupType OBJECT-TYPE
 | 
						|
    SYNTAX     CardType
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The type of card who belongs to the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 3 }
 | 
						|
     
 | 
						|
cmRedundancyGroupSyncEnabled OBJECT-TYPE
 | 
						|
    SYNTAX     TruthValue
 | 
						|
    MAX-ACCESS read-write 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The way of the synchronization in Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 4 }
 | 
						|
 | 
						|
cmRedundancyGroupActiveCard OBJECT-TYPE
 | 
						|
    SYNTAX     VariablePointer
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The corresponding OID of the Active/Primary Card in the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 5 }
 | 
						|
cmRedundancyGroupActiveCardState OBJECT-TYPE
 | 
						|
    SYNTAX     CmRedundancyUnitState
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The state of the Active Card in the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 6 }
 | 
						|
     
 | 
						|
cmRedundancyGroupStandbyCard OBJECT-TYPE
 | 
						|
    SYNTAX     VariablePointer
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The corresponding OID of the Standby/Secondary Card in the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 7 }
 | 
						|
     
 | 
						|
cmRedundancyGroupStandbyCardState OBJECT-TYPE
 | 
						|
    SYNTAX     CmRedundancyUnitState
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The state of the Standby Card in the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 8 }
 | 
						|
     
 | 
						|
cmRedundancyGroupLastSwitchOverTime OBJECT-TYPE
 | 
						|
    SYNTAX     TimeTicks
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The value of sysUpTime when last switch over occurred."
 | 
						|
     ::= { cmRedundancyGroupEntry 9 }
 | 
						|
 | 
						|
cmRedundancyGroupLastSwitchOverReason OBJECT-TYPE
 | 
						|
    SYNTAX     CmRedundancySwitchOverReason
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The reason for last switch over in the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 10 }
 | 
						|
 | 
						|
cmRedundancyGroupState OBJECT-TYPE
 | 
						|
    SYNTAX     CmRedundancyState
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The current state of the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 11 }
 | 
						|
 | 
						|
cmRedundancyGroupSyncStatus OBJECT-TYPE
 | 
						|
    SYNTAX     CmRedundancySyncStatus
 | 
						|
    MAX-ACCESS read-only 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "The current sync state of the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 12 }
 | 
						|
 | 
						|
cmRedundancyGroupAction OBJECT-TYPE
 | 
						|
    SYNTAX     CmRedundancyAction
 | 
						|
    MAX-ACCESS read-write 
 | 
						|
    STATUS     current
 | 
						|
    DESCRIPTION
 | 
						|
         "User initiated switch action of the Redundancy Group."
 | 
						|
     ::= { cmRedundancyGroupEntry 13 }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- Notification
 | 
						|
--
 | 
						|
 | 
						|
--
 | 
						|
-- Conformance
 | 
						|
--
 | 
						|
cmRedundancyCompliances OBJECT IDENTIFIER ::= {cmRedundancyConformance 1}
 | 
						|
cmRedundancyGroups      OBJECT IDENTIFIER ::= {cmRedundancyConformance 2}
 | 
						|
 | 
						|
cmRedundancyCompliance MODULE-COMPLIANCE
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
            "Describes the requirements for conformance to the CM Redundancy
 | 
						|
             group."
 | 
						|
    MODULE  -- this module
 | 
						|
        MANDATORY-GROUPS {
 | 
						|
              cmRedundancyObjectGroup
 | 
						|
        }
 | 
						|
    ::= { cmRedundancyCompliances 1 }
 | 
						|
 | 
						|
cmRedundancyObjectGroup OBJECT-GROUP
 | 
						|
    OBJECTS {
 | 
						|
    cmRedundancyGroupIndex, cmRedundancyGroupUserLabel, cmRedundancyGroupType, cmRedundancyGroupSyncEnabled,
 | 
						|
    cmRedundancyGroupActiveCard, cmRedundancyGroupActiveCardState, cmRedundancyGroupStandbyCard,
 | 
						|
    cmRedundancyGroupStandbyCardState, cmRedundancyGroupLastSwitchOverTime, cmRedundancyGroupLastSwitchOverReason,
 | 
						|
    cmRedundancyGroupState, cmRedundancyGroupSyncStatus, cmRedundancyGroupAction
 | 
						|
    }
 | 
						|
    STATUS  current
 | 
						|
    DESCRIPTION
 | 
						|
        "A collection of objects used to manage the CM Redundancy Object group."
 | 
						|
    ::= { cmRedundancyGroups 1 }
 | 
						|
 | 
						|
END
 |