2380 lines
		
	
	
		
			60 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			2380 lines
		
	
	
		
			60 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
--
 | 
						|
--defines ALCOMA-MIB for SNMP agent extension
 | 
						|
--Contents:	Global Registration Module
 | 
						|
--		ALCOMA OIDs - Enterprise 12140
 | 
						|
--Version:	4.8
 | 
						|
--Date:		31 August, 2016
 | 
						|
--Developed By: ing.Václav VACEK
 | 
						|
--              SW engineer
 | 
						|
--              ALCOMA a.s.
 | 
						|
 | 
						|
--
 | 
						|
--Copyright (c)2012 By ALCOMA a.s.
 | 
						|
--
 | 
						|
 | 
						|
ALCOMA-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
 | 
						|
IMPORTS
 | 
						|
	enterprises
 | 
						|
		FROM RFC1155-SMI
 | 
						|
	OBJECT-TYPE
 | 
						|
		FROM RFC-1212
 | 
						|
	DisplayString
 | 
						|
		FROM RFC1213-MIB;
 | 
						|
 | 
						|
 | 
						|
alcoma               OBJECT IDENTIFIER ::= { enterprises 12140 }
 | 
						|
products             OBJECT IDENTIFIER ::= { alcoma 1 }
 | 
						|
alMP                 OBJECT IDENTIFIER ::= { alcoma 2 }
 | 
						|
alRADIO-RELAY-LINK   OBJECT IDENTIFIER ::= { products 1 }
 | 
						|
alNMS                OBJECT IDENTIFIER ::= { products 2 }
 | 
						|
 | 
						|
-- Power Source MIB
 | 
						|
-- Parameters (Prefix Par)    
 | 
						|
 | 
						|
alStatusLED     OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 1 }
 | 
						|
 | 
						|
alEHW OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Hardware error."
 | 
						|
::= { alStatusLED 1 }
 | 
						|
     
 | 
						|
alESR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal error in radio."
 | 
						|
::= { alStatusLED 2 }
 | 
						|
 | 
						|
alESL OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal error on lines."
 | 
						|
::= { alStatusLED 3 }
 | 
						|
 | 
						|
alCA OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Non-standard command activate."
 | 
						|
::= { alStatusLED 4 }
 | 
						|
 | 
						|
local-station     OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 2 }
 | 
						|
 | 
						|
alL-General     OBJECT IDENTIFIER ::= { local-station 1 }
 | 
						|
 | 
						|
alLSupervisor OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),none(0),terminal(1),local(2),network(3),service(4),alcoma(5) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Active supervisor."
 | 
						|
::= { alL-General 1 }
 | 
						|
 | 
						|
alLConfiguration OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),undefined(0),cf2xE1(1),cf4xE1(2),cf1xE2(3),cf1xE1-Ethernet(4),cf1xE3-E1(7),cf1xEthernet(8),
 | 
						|
                            cf1xEthF-E1(9),
 | 
						|
                            cf1xEthF-E1-1xE1(10),cf1xEthF-E1-2xE1(11),cf1xEthF-E1-3xE1(12),cf1xEthF-E1-4xE1(13),
 | 
						|
                            cf1xEthF-E1-5xE1(14),cf1xEthF-E1-6xE1(15),cf1xEthF-E1-7xE1(16),cf1xEthF-E1-8xE1(17),
 | 
						|
                            cf1xEthF(18),
 | 
						|
                            cf1xEthF-1xE1(19),cf1xEthF-2xE1(20),cf1xEthF-3xE1(21),cf1xEthF-4xE1(22),
 | 
						|
                            cf1xEthF-5xE1(23),cf1xEthF-6xE1(24),cf1xEthF-7xE1(25),cf1xEthF-8xE1(26),
 | 
						|
                            cf2xFEth(27),cf2xFEth-1xE1(28),
 | 
						|
                            cf4xFEth-2xE1(29),
 | 
						|
                            cf2xGEth(30),cf2xGEth-SFP100(31),cf2xGEth-SFP1000(32),cf2xGEth-SFPSG(33) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"IDU configuration."
 | 
						|
::= { alL-General 2 }
 | 
						|
 | 
						|
alLStatus OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(0),ok(1),warning(2),error(3) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Station alarm status."
 | 
						|
::= { alL-General 3 }
 | 
						|
 | 
						|
alLHistory OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"History alarm status."
 | 
						|
::= { alL-General 4 }
 | 
						|
 | 
						|
alLIAISL OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Automatic AIS ignored."
 | 
						|
::= { alL-General 5 }
 | 
						|
 | 
						|
alLILEVPWR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Low RX or TX level alarms ignored."
 | 
						|
::= { alL-General 6 }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
alL-ODU     OBJECT IDENTIFIER ::= { local-station 2 }
 | 
						|
 | 
						|
alLRX-Level OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal receiver level."
 | 
						|
::= { alL-ODU 1 }
 | 
						|
 | 
						|
alLTX-PWR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitter power level."
 | 
						|
::= { alL-ODU 2 }
 | 
						|
 | 
						|
alLMode-TX OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),manual(1),atpc(2) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Mode of power control."
 | 
						|
::= { alL-ODU 3 }
 | 
						|
 | 
						|
alLODU-LB OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"ODU line-loopback."
 | 
						|
::= { alL-ODU 4 }
 | 
						|
 | 
						|
alL-Modem     OBJECT IDENTIFIER ::= { local-station 3 }
 | 
						|
 | 
						|
alLQuality OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),out(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Quality of 4-level modulation."
 | 
						|
::= { alL-Modem 1 }
 | 
						|
 | 
						|
alL-Supply     OBJECT IDENTIFIER ::= { local-station 4 }
 | 
						|
 | 
						|
alLVoltage-5V OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),high(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Voltage 5V high."
 | 
						|
::= { alL-Supply 1 }
 | 
						|
 | 
						|
alLVoltage-5Vor15V OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Voltage 5V or 15V low."
 | 
						|
::= { alL-Supply 2 }
 | 
						|
 | 
						|
alLVoltage-24V OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Voltage 24V low."
 | 
						|
::= { alL-Supply 3 }
 | 
						|
 | 
						|
alLCurrent-ODU OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),out(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"ODU current range."
 | 
						|
::= { alL-Supply 4 }
 | 
						|
 | 
						|
alLInput OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input voltage low."
 | 
						|
::= { alL-Supply 5 }
 | 
						|
 | 
						|
alL-IDU     OBJECT IDENTIFIER ::= { local-station 5 }
 | 
						|
 | 
						|
alLEEPROM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"EEPROM memory status."
 | 
						|
::= { alL-IDU 1 }
 | 
						|
 | 
						|
alLRAM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"RAM memory status."
 | 
						|
::= { alL-IDU 2 }
 | 
						|
 | 
						|
alLBattery OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"RAM backup battery voltage."
 | 
						|
::= { alL-IDU 3 }
 | 
						|
 | 
						|
alLCommIDU OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication status with blocks of IDU."
 | 
						|
::= { alL-IDU 4 }
 | 
						|
 | 
						|
alLCommRMT OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication status with remote station."
 | 
						|
::= { alL-IDU 5 }
 | 
						|
 | 
						|
alL-MUX     OBJECT IDENTIFIER ::= { local-station 6 }
 | 
						|
 | 
						|
alLBER-10E6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"BER > 10E-6."
 | 
						|
::= { alL-MUX 1 }
 | 
						|
 | 
						|
alLBER-10E4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"BER > 10E-4."
 | 
						|
::= { alL-MUX 2 }
 | 
						|
 | 
						|
alLFrame OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),loss(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Frame LOSS."
 | 
						|
::= { alL-MUX 3 }
 | 
						|
 | 
						|
alL-PDH1    OBJECT IDENTIFIER ::= { local-station 7 }
 | 
						|
 | 
						|
alLPDHFrame OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),loss(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"PDH1 frame LOSS."
 | 
						|
::= { alL-PDH1 1 }
 | 
						|
 | 
						|
alLAISPDH OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to PDH1 frame."
 | 
						|
::= { alL-PDH1 2 }
 | 
						|
 | 
						|
alLLLBPDH OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on PDH1 frame."
 | 
						|
::= { alL-PDH1 3 }
 | 
						|
 | 
						|
alLRLBPDH OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on PDH1 frame."
 | 
						|
::= { alL-PDH1 4 }
 | 
						|
 | 
						|
alL-Line1     OBJECT IDENTIFIER ::= { local-station 9 }
 | 
						|
 | 
						|
alLOSS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 1."
 | 
						|
::= { alL-Line1 1 }
 | 
						|
 | 
						|
alILOSS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 1."
 | 
						|
::= { alL-Line1 2 }
 | 
						|
 | 
						|
alAIS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 1."
 | 
						|
::= { alL-Line1 3 }
 | 
						|
 | 
						|
alAISL1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 1."
 | 
						|
::= { alL-Line1 4 }
 | 
						|
 | 
						|
alLLB1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 1."
 | 
						|
::= { alL-Line1 5 }
 | 
						|
 | 
						|
alRLB1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 1."
 | 
						|
::= { alL-Line1 6 }
 | 
						|
 | 
						|
alL-Line2     OBJECT IDENTIFIER ::= { local-station 10 }
 | 
						|
 | 
						|
alLLOSS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 2."
 | 
						|
::= { alL-Line2 1 }
 | 
						|
 | 
						|
alLILOSS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 2."
 | 
						|
::= { alL-Line2 2 }
 | 
						|
 | 
						|
alLAIS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 2."
 | 
						|
::= { alL-Line2 3 }
 | 
						|
 | 
						|
alLAISL2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 2."
 | 
						|
::= { alL-Line2 4 }
 | 
						|
 | 
						|
alLLLB2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 2."
 | 
						|
::= { alL-Line2 5 }
 | 
						|
 | 
						|
alLRLB2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 2."
 | 
						|
::= { alL-Line2 6 }
 | 
						|
 | 
						|
alL-Line3     OBJECT IDENTIFIER ::= { local-station 11 }
 | 
						|
 | 
						|
alLLOSS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 3."
 | 
						|
::= { alL-Line3 1 }
 | 
						|
 | 
						|
alLILOSS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 3."
 | 
						|
::= { alL-Line3 2 }
 | 
						|
 | 
						|
alLAIS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 3."
 | 
						|
::= { alL-Line3 3 }
 | 
						|
 | 
						|
alLAISL3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 3."
 | 
						|
::= { alL-Line3 4 }
 | 
						|
 | 
						|
alLLLB3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 3."
 | 
						|
::= { alL-Line3 5 }
 | 
						|
 | 
						|
alLRLB3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 3."
 | 
						|
::= { alL-Line3 6 }
 | 
						|
 | 
						|
alL-Line4     OBJECT IDENTIFIER ::= { local-station 12 }
 | 
						|
 | 
						|
alLLOSS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 4."
 | 
						|
::= { alL-Line4 1 }
 | 
						|
 | 
						|
alLILOSS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 4."
 | 
						|
::= { alL-Line4 2 }
 | 
						|
 | 
						|
alLAIS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 4."
 | 
						|
::= { alL-Line4 3 }
 | 
						|
 | 
						|
alLAISL4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 4."
 | 
						|
::= { alL-Line4 4 }
 | 
						|
 | 
						|
alLLLB4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 4."
 | 
						|
::= { alL-Line4 5 }
 | 
						|
 | 
						|
alLRLB4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 4."
 | 
						|
::= { alL-Line4 6 }
 | 
						|
 | 
						|
alL-Line5     OBJECT IDENTIFIER ::= { local-station 13 }
 | 
						|
 | 
						|
alLLOSS5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 5."
 | 
						|
::= { alL-Line5 1 }
 | 
						|
 | 
						|
alLILOSS5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 5."
 | 
						|
::= { alL-Line5 2 }
 | 
						|
 | 
						|
alLAIS5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 5."
 | 
						|
::= { alL-Line5 3 }
 | 
						|
 | 
						|
alLAISL5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 5."
 | 
						|
::= { alL-Line5 4 }
 | 
						|
 | 
						|
alLLLB5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 5."
 | 
						|
::= { alL-Line5 5 }
 | 
						|
 | 
						|
alLRLB5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 5."
 | 
						|
::= { alL-Line5 6 }
 | 
						|
 | 
						|
alL-Line6     OBJECT IDENTIFIER ::= { local-station 14 }
 | 
						|
 | 
						|
alLLOSS6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 6."
 | 
						|
::= { alL-Line6 1 }
 | 
						|
 | 
						|
alLILOSS6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 6."
 | 
						|
::= { alL-Line6 2 }
 | 
						|
 | 
						|
alLAIS6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 6."
 | 
						|
::= { alL-Line6 3 }
 | 
						|
 | 
						|
alLAISL6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 6."
 | 
						|
::= { alL-Line6 4 }
 | 
						|
 | 
						|
alLLLB6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 6."
 | 
						|
::= { alL-Line6 5 }
 | 
						|
 | 
						|
alLRLB6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 6."
 | 
						|
::= { alL-Line6 6 }
 | 
						|
 | 
						|
alL-Line7     OBJECT IDENTIFIER ::= { local-station 15 }
 | 
						|
 | 
						|
alLLOSS7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 7."
 | 
						|
::= { alL-Line7 1 }
 | 
						|
 | 
						|
alLILOSS7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 7."
 | 
						|
::= { alL-Line7 2 }
 | 
						|
 | 
						|
alLAIS7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 7."
 | 
						|
::= { alL-Line7 3 }
 | 
						|
 | 
						|
alLAISL7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 7."
 | 
						|
::= { alL-Line7 4 }
 | 
						|
 | 
						|
alLLLB7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 7."
 | 
						|
::= { alL-Line7 5 }
 | 
						|
 | 
						|
alLRLB7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 7."
 | 
						|
::= { alL-Line7 6 }
 | 
						|
 | 
						|
alL-Line8     OBJECT IDENTIFIER ::= { local-station 16 }
 | 
						|
 | 
						|
alLLOSS8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 8."
 | 
						|
::= { alL-Line8 1 }
 | 
						|
 | 
						|
alLILOSS8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 8."
 | 
						|
::= { alL-Line8 2 }
 | 
						|
 | 
						|
alLAIS8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 8."
 | 
						|
::= { alL-Line8 3 }
 | 
						|
 | 
						|
alLAISL8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 8."
 | 
						|
::= { alL-Line8 4 }
 | 
						|
 | 
						|
alLLLB8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 8."
 | 
						|
::= { alL-Line8 5 }
 | 
						|
 | 
						|
alLRLB8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 8."
 | 
						|
::= { alL-Line8 6 }
 | 
						|
 | 
						|
alL-Line9     OBJECT IDENTIFIER ::= { local-station 17 }
 | 
						|
 | 
						|
alLLOSS9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 9."
 | 
						|
::= { alL-Line9 1 }
 | 
						|
 | 
						|
alLILOSS9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 9."
 | 
						|
::= { alL-Line9 2 }
 | 
						|
 | 
						|
alLAIS9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 9."
 | 
						|
::= { alL-Line9 3 }
 | 
						|
 | 
						|
alLAISL9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 9."
 | 
						|
::= { alL-Line9 4 }
 | 
						|
 | 
						|
alLLLB9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 9."
 | 
						|
::= { alL-Line9 5 }
 | 
						|
 | 
						|
alLRLB9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 9."
 | 
						|
::= { alL-Line9 6 }
 | 
						|
 | 
						|
alL-Line10    OBJECT IDENTIFIER ::= { local-station 18 }
 | 
						|
 | 
						|
alLLOSS10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 10."
 | 
						|
::= { alL-Line10 1 }
 | 
						|
 | 
						|
alLILOSS10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 10."
 | 
						|
::= { alL-Line10 2 }
 | 
						|
 | 
						|
alLAIS10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 10."
 | 
						|
::= { alL-Line10 3 }
 | 
						|
 | 
						|
alLAISL10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 10."
 | 
						|
::= { alL-Line10 4 }
 | 
						|
 | 
						|
alLLLB10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 10."
 | 
						|
::= { alL-Line10 5 }
 | 
						|
 | 
						|
alLRLB10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 10."
 | 
						|
::= { alL-Line10 6 }
 | 
						|
 | 
						|
alL-Line11    OBJECT IDENTIFIER ::= { local-station 19 }
 | 
						|
 | 
						|
alLLOSS11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 11."
 | 
						|
::= { alL-Line11 1 }
 | 
						|
 | 
						|
alLILOSS11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 11."
 | 
						|
::= { alL-Line11 2 }
 | 
						|
 | 
						|
alLAIS11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 11."
 | 
						|
::= { alL-Line11 3 }
 | 
						|
 | 
						|
alLAISL11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 11."
 | 
						|
::= { alL-Line11 4 }
 | 
						|
 | 
						|
alLLLB11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 11."
 | 
						|
::= { alL-Line11 5 }
 | 
						|
 | 
						|
alLRLB11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 11."
 | 
						|
::= { alL-Line11 6 }
 | 
						|
 | 
						|
alL-Line12    OBJECT IDENTIFIER ::= { local-station 20 }
 | 
						|
 | 
						|
alLLOSS12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 12."
 | 
						|
::= { alL-Line12 1 }
 | 
						|
 | 
						|
alLILOSS12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 12."
 | 
						|
::= { alL-Line12 2 }
 | 
						|
 | 
						|
alLAIS12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 12."
 | 
						|
::= { alL-Line12 3 }
 | 
						|
 | 
						|
alLAISL12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 12."
 | 
						|
::= { alL-Line12 4 }
 | 
						|
 | 
						|
alLLLB12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 12."
 | 
						|
::= { alL-Line12 5 }
 | 
						|
 | 
						|
alLRLB12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 12."
 | 
						|
::= { alL-Line12 6 }
 | 
						|
 | 
						|
remote-station     OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 3 }
 | 
						|
 | 
						|
alR-General     OBJECT IDENTIFIER ::= { remote-station 1 }
 | 
						|
 | 
						|
alRSupervisor OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),none(0),terminal(1),local(2),network(3),service(4),alcoma(5) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Active supervisor."
 | 
						|
::= { alR-General 1 }
 | 
						|
 | 
						|
alRConfiguration OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),undefined(0),cf2xE1(1),cf4xE1(2),cf1xE2(3),cf1xE1-Ethernet(4),cf1xE3-E1(7),cf1xEthernet(8),
 | 
						|
                            cf1xEthF-E1(9),
 | 
						|
                            cf1xEthF-E1-1xE1(10),cf1xEthF-E1-2xE1(11),cf1xEthF-E1-3xE1(12),cf1xEthF-E1-4xE1(13),
 | 
						|
                            cf1xEthF-E1-5xE1(14),cf1xEthF-E1-6xE1(15),cf1xEthF-E1-7xE1(16),cf1xEthF-E1-8xE1(17),
 | 
						|
                            cf1xEthF(18),
 | 
						|
                            cf1xEthF-1xE1(19),cf1xEthF-2xE1(20),cf1xEthF-3xE1(21),cf1xEthF-4xE1(22),
 | 
						|
                            cf1xEthF-5xE1(23),cf1xEthF-6xE1(24),cf1xEthF-7xE1(25),cf1xEthF-8xE1(26),
 | 
						|
                            cf2xFEth(27),cf2xFEth-1xE1(28),
 | 
						|
                            cf4xFEth-2xE1(29),
 | 
						|
                            cf2xGEth(30),cf2xGEth-SFP100(31),cf2xGEth-SFP1000(32),cf2xGEth-SFPSG(33) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"IDU configuration."
 | 
						|
::= { alR-General 2 }
 | 
						|
 | 
						|
alRStatus OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(0),ok(1),warning(2),error(3) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Station alarm status."
 | 
						|
::= { alR-General 3 }
 | 
						|
 | 
						|
alRHistory OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"History alarm status."
 | 
						|
::= { alR-General 4 }
 | 
						|
 | 
						|
alRIAISL OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Automatic AIS ignored."
 | 
						|
::= { alR-General 5 }
 | 
						|
 | 
						|
alRILEVPWR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Low RX or TX level alarms ignored."
 | 
						|
::= { alR-General 6 }
 | 
						|
 | 
						|
alR-ODU     OBJECT IDENTIFIER ::= { remote-station 2 }
 | 
						|
 | 
						|
alRRX-Level OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal receiver level."
 | 
						|
::= { alR-ODU 1 }
 | 
						|
 | 
						|
alRTX-PWR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitter power level."
 | 
						|
::= { alR-ODU 2 }
 | 
						|
 | 
						|
alRMode-TX OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),manual(1),atpc(2) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Mode of power control."
 | 
						|
::= { alR-ODU 3 }
 | 
						|
 | 
						|
alRODU-LB OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"ODU line-loopback."
 | 
						|
::= { alR-ODU 4 }
 | 
						|
 | 
						|
alR-Modem     OBJECT IDENTIFIER ::= { remote-station 3 }
 | 
						|
 | 
						|
alRQuality OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),out(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Quality of 4-level modulation."
 | 
						|
::= { alR-Modem 1 }
 | 
						|
 | 
						|
alR-Supply     OBJECT IDENTIFIER ::= { remote-station 4 }
 | 
						|
 | 
						|
alRVoltage-5V OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),high(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Voltage 5V high."
 | 
						|
::= { alR-Supply 1 }
 | 
						|
 | 
						|
alRVoltage-5Vor15V OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Voltage 5V or 15V low."
 | 
						|
::= { alR-Supply 2 }
 | 
						|
 | 
						|
alRVoltage-24V OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Voltage 24V low."
 | 
						|
::= { alR-Supply 3 }
 | 
						|
 | 
						|
alRCurrent-ODU OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),out(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"ODU current range."
 | 
						|
::= { alR-Supply 4 }
 | 
						|
 | 
						|
alRInput OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input voltage low."
 | 
						|
::= { alR-Supply 5 }
 | 
						|
 | 
						|
alR-IDU     OBJECT IDENTIFIER ::= { remote-station 5 }
 | 
						|
 | 
						|
alREEPROM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"EEPROM memory status."
 | 
						|
::= { alR-IDU 1 }
 | 
						|
 | 
						|
alRRAM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"RAM memory status."
 | 
						|
::= { alR-IDU 2 }
 | 
						|
 | 
						|
alRBattery OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"RAM backup battery voltage."
 | 
						|
::= { alR-IDU 3 }
 | 
						|
 | 
						|
alRCommIDU OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication status with blocks of IDU."
 | 
						|
::= { alR-IDU 4 }
 | 
						|
 | 
						|
alRCommRMT OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication status with remote station."
 | 
						|
::= { alR-IDU 5 }
 | 
						|
 | 
						|
alR-MUX     OBJECT IDENTIFIER ::= { remote-station 6 }
 | 
						|
 | 
						|
alRBER-10E6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"BER > 10E-6."
 | 
						|
::= { alR-MUX 1 }
 | 
						|
 | 
						|
alRBER-10E4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"BER > 10E-4."
 | 
						|
::= { alR-MUX 2 }
 | 
						|
 | 
						|
alRFrame OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),loss(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Frame LOSS."
 | 
						|
::= { alR-MUX 3 }
 | 
						|
 | 
						|
alR-PDH1    OBJECT IDENTIFIER ::= { remote-station 7 }
 | 
						|
 | 
						|
alRPDHFrame OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),loss(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"PDH1 frame LOSS."
 | 
						|
::= { alR-PDH1 1 }
 | 
						|
 | 
						|
alRAISPDH OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to frame PDH1."
 | 
						|
::= { alR-PDH1 2 }
 | 
						|
 | 
						|
alRLLBPDH OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on PDH1 frame."
 | 
						|
::= { alR-PDH1 3 }
 | 
						|
 | 
						|
alRRLBPDH OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on PDH1 frame."
 | 
						|
::= { alR-PDH1 4 }
 | 
						|
 | 
						|
alR-Line1     OBJECT IDENTIFIER ::= { remote-station 9 }
 | 
						|
 | 
						|
alRLOSS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 1."
 | 
						|
::= { alR-Line1 1 }
 | 
						|
 | 
						|
alRILOSS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 1."
 | 
						|
::= { alR-Line1 2 }
 | 
						|
 | 
						|
alRAIS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 1."
 | 
						|
::= { alR-Line1 3 }
 | 
						|
 | 
						|
alRAISL1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 1."
 | 
						|
::= { alR-Line1 4 }
 | 
						|
 | 
						|
alRLLB1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 1."
 | 
						|
::= { alR-Line1 5 }
 | 
						|
 | 
						|
alRRLB1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 1."
 | 
						|
::= { alR-Line1 6 }
 | 
						|
 | 
						|
alR-Line2     OBJECT IDENTIFIER ::= { remote-station 10 }
 | 
						|
 | 
						|
alRLOSS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 2."
 | 
						|
::= { alR-Line2 1 }
 | 
						|
 | 
						|
alRILOSS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 2."
 | 
						|
::= { alR-Line2 2 }
 | 
						|
 | 
						|
alRAIS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 2."
 | 
						|
::= { alR-Line2 3 }
 | 
						|
 | 
						|
alRAISL2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 2."
 | 
						|
::= { alR-Line2 4 }
 | 
						|
 | 
						|
alRLLB2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 2."
 | 
						|
::= { alR-Line2 5 }
 | 
						|
 | 
						|
alRRLB2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 2."
 | 
						|
::= { alR-Line2 6 }
 | 
						|
 | 
						|
alR-Line3     OBJECT IDENTIFIER ::= { remote-station 11 }
 | 
						|
 | 
						|
alRLOSS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 3."
 | 
						|
::= { alR-Line3 1 }
 | 
						|
 | 
						|
alRILOSS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 3."
 | 
						|
::= { alR-Line3 2 }
 | 
						|
 | 
						|
alRAIS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 3."
 | 
						|
::= { alR-Line3 3 }
 | 
						|
 | 
						|
alRAISL3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 3."
 | 
						|
::= { alR-Line3 4 }
 | 
						|
 | 
						|
alRLLB3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 3."
 | 
						|
::= { alR-Line3 5 }
 | 
						|
 | 
						|
alRRLB3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 3."
 | 
						|
::= { alR-Line3 6 }
 | 
						|
 | 
						|
alR-Line4     OBJECT IDENTIFIER ::= { remote-station 12 }
 | 
						|
 | 
						|
alRLOSS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 4."
 | 
						|
::= { alR-Line4 1 }
 | 
						|
 | 
						|
alRILOSS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 4."
 | 
						|
::= { alR-Line4 2 }
 | 
						|
 | 
						|
alRAIS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 4."
 | 
						|
::= { alR-Line4 3 }
 | 
						|
 | 
						|
alRAISL4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 4."
 | 
						|
::= { alR-Line4 4 }
 | 
						|
 | 
						|
alRLLB4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 4."
 | 
						|
::= { alR-Line4 5 }
 | 
						|
 | 
						|
alRRLB4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 4."
 | 
						|
::= { alR-Line4 6 }
 | 
						|
 | 
						|
alR-Line5     OBJECT IDENTIFIER ::= { remote-station 13 }
 | 
						|
 | 
						|
alRLOSS5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 5."
 | 
						|
::= { alR-Line5 1 }
 | 
						|
 | 
						|
alRILOSS5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 5."
 | 
						|
::= { alR-Line5 2 }
 | 
						|
 | 
						|
alRAIS5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 5."
 | 
						|
::= { alR-Line5 3 }
 | 
						|
 | 
						|
alRAISL5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 5."
 | 
						|
::= { alR-Line5 4 }
 | 
						|
 | 
						|
alRLLB5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 5."
 | 
						|
::= { alR-Line5 5 }
 | 
						|
 | 
						|
alRRLB5 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 5."
 | 
						|
::= { alR-Line5 6 }
 | 
						|
 | 
						|
alR-Line6     OBJECT IDENTIFIER ::= { remote-station 14 }
 | 
						|
 | 
						|
alRLOSS6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 6."
 | 
						|
::= { alR-Line6 1 }
 | 
						|
 | 
						|
alRILOSS6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 6."
 | 
						|
::= { alR-Line6 2 }
 | 
						|
 | 
						|
alRAIS6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 6."
 | 
						|
::= { alR-Line6 3 }
 | 
						|
 | 
						|
alRAISL6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 6."
 | 
						|
::= { alR-Line6 4 }
 | 
						|
 | 
						|
alRLLB6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 6."
 | 
						|
::= { alR-Line6 5 }
 | 
						|
 | 
						|
alRRLB6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 6."
 | 
						|
::= { alR-Line6 6 }
 | 
						|
 | 
						|
alR-Line7     OBJECT IDENTIFIER ::= { remote-station 15 }
 | 
						|
 | 
						|
alRLOSS7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 7."
 | 
						|
::= { alR-Line7 1 }
 | 
						|
 | 
						|
alRILOSS7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 7."
 | 
						|
::= { alR-Line7 2 }
 | 
						|
 | 
						|
alRAIS7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 7."
 | 
						|
::= { alR-Line7 3 }
 | 
						|
 | 
						|
alRAISL7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 7."
 | 
						|
::= { alR-Line7 4 }
 | 
						|
 | 
						|
alRLLB7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 7."
 | 
						|
::= { alR-Line7 5 }
 | 
						|
 | 
						|
alRRLB7 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 7."
 | 
						|
::= { alR-Line7 6 }
 | 
						|
 | 
						|
alR-Line8     OBJECT IDENTIFIER ::= { remote-station 16 }
 | 
						|
 | 
						|
alRLOSS8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 8."
 | 
						|
::= { alR-Line8 1 }
 | 
						|
 | 
						|
alRILOSS8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 8."
 | 
						|
::= { alR-Line8 2 }
 | 
						|
 | 
						|
alRAIS8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 8."
 | 
						|
::= { alR-Line8 3 }
 | 
						|
 | 
						|
alRAISL8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 8."
 | 
						|
::= { alR-Line8 4 }
 | 
						|
 | 
						|
alRLLB8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 8."
 | 
						|
::= { alR-Line8 5 }
 | 
						|
 | 
						|
alRRLB8 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 8."
 | 
						|
::= { alR-Line8 6 }
 | 
						|
 | 
						|
alR-Line9     OBJECT IDENTIFIER ::= { remote-station 17 }
 | 
						|
 | 
						|
alRLOSS9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 9."
 | 
						|
::= { alR-Line9 1 }
 | 
						|
 | 
						|
alRILOSS9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 9."
 | 
						|
::= { alR-Line9 2 }
 | 
						|
 | 
						|
alRAIS9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 9."
 | 
						|
::= { alR-Line9 3 }
 | 
						|
 | 
						|
alRAISL9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 9."
 | 
						|
::= { alR-Line9 4 }
 | 
						|
 | 
						|
alRLLB9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 9."
 | 
						|
::= { alR-Line9 5 }
 | 
						|
 | 
						|
alRRLB9 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 9."
 | 
						|
::= { alR-Line9 6 }
 | 
						|
 | 
						|
alR-Line10    OBJECT IDENTIFIER ::= { remote-station 18 }
 | 
						|
 | 
						|
alRLOSS10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 10."
 | 
						|
::= { alR-Line10 1 }
 | 
						|
 | 
						|
alRILOSS10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 10."
 | 
						|
::= { alR-Line10 2 }
 | 
						|
 | 
						|
alRAIS10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 10."
 | 
						|
::= { alR-Line10 3 }
 | 
						|
 | 
						|
alRAISL10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 10."
 | 
						|
::= { alR-Line10 4 }
 | 
						|
 | 
						|
alRLLB10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 10."
 | 
						|
::= { alR-Line10 5 }
 | 
						|
 | 
						|
alRRLB10 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 10."
 | 
						|
::= { alR-Line10 6 }
 | 
						|
 | 
						|
alR-Line11    OBJECT IDENTIFIER ::= { remote-station 19 }
 | 
						|
 | 
						|
alRLOSS11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 11."
 | 
						|
::= { alR-Line11 1 }
 | 
						|
 | 
						|
alRILOSS11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 11."
 | 
						|
::= { alR-Line11 2 }
 | 
						|
 | 
						|
alRAIS11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 11."
 | 
						|
::= { alR-Line11 3 }
 | 
						|
 | 
						|
alRAISL11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 11."
 | 
						|
::= { alR-Line11 4 }
 | 
						|
 | 
						|
alRLLB11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 11."
 | 
						|
::= { alR-Line11 5 }
 | 
						|
 | 
						|
alRRLB11 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 11."
 | 
						|
::= { alR-Line11 6 }
 | 
						|
 | 
						|
alR-Line12    OBJECT IDENTIFIER ::= { remote-station 20 }
 | 
						|
 | 
						|
alRLOSS12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 12."
 | 
						|
::= { alR-Line12 1 }
 | 
						|
 | 
						|
alRILOSS12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 12."
 | 
						|
::= { alR-Line12 2 }
 | 
						|
 | 
						|
alRAIS12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 12."
 | 
						|
::= { alR-Line12 3 }
 | 
						|
 | 
						|
alRAISL12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 12."
 | 
						|
::= { alR-Line12 4 }
 | 
						|
 | 
						|
alRLLB12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 12."
 | 
						|
::= { alR-Line12 5 }
 | 
						|
 | 
						|
alRRLB12 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 12."
 | 
						|
::= { alR-Line12 6 }
 | 
						|
 | 
						|
alRRLTrap     OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 4 }
 | 
						|
 | 
						|
alLast-Message OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Message giving more detailed information on change of alarms status."
 | 
						|
::= { alRRLTrap 1 } 
 | 
						|
 | 
						|
traps                   OBJECT IDENTIFIER ::= { alcoma 0 }
 | 
						|
 | 
						|
generalOFF              OBJECT IDENTIFIER ::= { traps 1 }
 | 
						|
generalOK               OBJECT IDENTIFIER ::= { traps 2 }
 | 
						|
generalWAR              OBJECT IDENTIFIER ::= { traps 3 }
 | 
						|
generalERR              OBJECT IDENTIFIER ::= { traps 4 }
 | 
						|
receiverLowAlarmOn      OBJECT IDENTIFIER ::= { traps 5 }
 | 
						|
receiverLowAlarmOff     OBJECT IDENTIFIER ::= { traps 6 }
 | 
						|
transmitterLowAlarmOn   OBJECT IDENTIFIER ::= { traps 7 }
 | 
						|
transmitterLowAlarmOff  OBJECT IDENTIFIER ::= { traps 8 }
 | 
						|
signalQualityAlarmOn    OBJECT IDENTIFIER ::= { traps 9 }
 | 
						|
signalQualityAlarmOff   OBJECT IDENTIFIER ::= { traps 10 }
 | 
						|
ber6EAlarmOn            OBJECT IDENTIFIER ::= { traps 11 }
 | 
						|
ber6EAlarmOff           OBJECT IDENTIFIER ::= { traps 12 }
 | 
						|
ber4EAlarmOn            OBJECT IDENTIFIER ::= { traps 13 }
 | 
						|
ber4EAlarmOff           OBJECT IDENTIFIER ::= { traps 14 }
 | 
						|
inputSupplyAlarmOn      OBJECT IDENTIFIER ::= { traps 15 }
 | 
						|
inputSupplyAlarmOff     OBJECT IDENTIFIER ::= { traps 16 }
 | 
						|
aisFromLineAlarmOn      OBJECT IDENTIFIER ::= { traps 17 }
 | 
						|
aisFromLineAlarmOff     OBJECT IDENTIFIER ::= { traps 18 }
 | 
						|
aisToLineAlarmOn        OBJECT IDENTIFIER ::= { traps 19 }
 | 
						|
aisToLineAlarmOff       OBJECT IDENTIFIER ::= { traps 20 }
 | 
						|
aisToPdhAlarmOn         OBJECT IDENTIFIER ::= { traps 21 }
 | 
						|
aisToPdhAlarmOff        OBJECT IDENTIFIER ::= { traps 22 }
 | 
						|
lossAtLineAlarmOn       OBJECT IDENTIFIER ::= { traps 23 }
 | 
						|
lossAtLineAlarmOff      OBJECT IDENTIFIER ::= { traps 24 }
 | 
						|
lossAtPdhAlarmOn        OBJECT IDENTIFIER ::= { traps 25 }
 | 
						|
lossAtPdhAlarmOff       OBJECT IDENTIFIER ::= { traps 26 }
 | 
						|
lossAtFrameAlarmOn      OBJECT IDENTIFIER ::= { traps 27 }
 | 
						|
lossAtFrameAlarmOff     OBJECT IDENTIFIER ::= { traps 28 }
 | 
						|
 | 
						|
trapParam               OBJECT IDENTIFIER ::= { alNMS 1 }
 | 
						|
 | 
						|
nmsTrapTime OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Time of alarms scan."
 | 
						|
::= { trapParam 1 } 
 | 
						|
 | 
						|
trapSequence OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Number of trap sequence."
 | 
						|
::= { trapParam 2 } 
 | 
						|
 | 
						|
mwRouteID OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Identification of microwave route."
 | 
						|
::= { trapParam 3 } 
 | 
						|
 | 
						|
stationID OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Identification of Radio Relay Link station."
 | 
						|
::= { trapParam 4 } 
 | 
						|
 | 
						|
stationName OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Name of Radio Relay Link station."
 | 
						|
::= { trapParam 5 } 
 | 
						|
 | 
						|
mgmtGWaddr OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"IP address of Management Gateway."
 | 
						|
::= { trapParam 6 }
 | 
						|
 | 
						|
lineID OBJECT-TYPE
 | 
						|
	SYNTAX		DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line ID number."
 | 
						|
::= { trapParam 7 }
 | 
						|
 | 
						|
-- MIB pro spoje rady MPx
 | 
						|
 | 
						|
alMPStatusLED     OBJECT IDENTIFIER ::= { alMP 1 }
 | 
						|
 | 
						|
alMPEHW OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Hardware error."
 | 
						|
::= { alMPStatusLED 1 }
 | 
						|
     
 | 
						|
alMPESR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal error in radio."
 | 
						|
::= { alMPStatusLED 2 }
 | 
						|
 | 
						|
alMPESL OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal error on lines."
 | 
						|
::= { alMPStatusLED 3 }
 | 
						|
 | 
						|
alMPCA OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Non-standard command activate."
 | 
						|
::= { alMPStatusLED 4 }
 | 
						|
 | 
						|
alMPGeneral     OBJECT IDENTIFIER ::= { alMP 2 }
 | 
						|
 | 
						|
alMPSupervisor OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),none(0),terminal(1),local(2),network(3),service(4),alcoma(5) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Active supervisor."
 | 
						|
::= { alMPGeneral 1 }
 | 
						|
 | 
						|
alMPConfiguration OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),undefined(0),cf2xE1(1),cf4xE1(2),cf1xE2(3),cf1xE1-Ethernet(4),cf1xE3-E1(7),cf1xEthernet(8),
 | 
						|
                            cf1xEthF-E1(9),
 | 
						|
                            cf1xEthF-E1-1xE1(10),cf1xEthF-E1-2xE1(11),cf1xEthF-E1-3xE1(12),cf1xEthF-E1-4xE1(13),
 | 
						|
                            cf1xEthF-E1-5xE1(14),cf1xEthF-E1-6xE1(15),cf1xEthF-E1-7xE1(16),cf1xEthF-E1-8xE1(17),
 | 
						|
                            cf1xEthF(18),
 | 
						|
                            cf1xEthF-1xE1(19),cf1xEthF-2xE1(20),cf1xEthF-3xE1(21),cf1xEthF-4xE1(22),
 | 
						|
                            cf1xEthF-5xE1(23),cf1xEthF-6xE1(24),cf1xEthF-7xE1(25),cf1xEthF-8xE1(26),
 | 
						|
                            cf2xFEth(27),cf2xFEth-1xE1(28),
 | 
						|
                            cf4xFEth-2xE1(29),
 | 
						|
                            cf2xGEth(30),cf2xGEth-SFP100(31),cf2xGEth-SFP1000(32),cf2xGEth-SFPSG(33) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"IDU configuration."
 | 
						|
::= { alMPGeneral 2 }
 | 
						|
 | 
						|
alMPStatus OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(0),ok(1),warning(2),error(3) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Station alarm status."
 | 
						|
::= { alMPGeneral 3 }
 | 
						|
 | 
						|
alMPHistory OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"History alarm status."
 | 
						|
::= { alMPGeneral 4 }
 | 
						|
 | 
						|
alMPIAISL OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Automatic AIS ignored."
 | 
						|
::= { alMPGeneral 5 }
 | 
						|
 | 
						|
alMPILEVPWR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Low RX or TX level alarms ignored."
 | 
						|
::= { alMPGeneral 6 }
 | 
						|
 | 
						|
alMPExpiration OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..100))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Expiration status."
 | 
						|
::= { alMPGeneral 7 }
 | 
						|
 | 
						|
alMPDevType OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..100))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Device type."
 | 
						|
::= { alMPGeneral 8 }
 | 
						|
 | 
						|
alMPModel OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..100))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Terminal model."
 | 
						|
::= { alMPGeneral 9 }
 | 
						|
 | 
						|
alMPVersionSW OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..100))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Firmware version."
 | 
						|
::= { alMPGeneral 10 }
 | 
						|
 | 
						|
alMPODU     OBJECT IDENTIFIER ::= { alMP 3 }
 | 
						|
 | 
						|
alMPTuneTX OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitter frequency [MHz]."
 | 
						|
::= { alMPODU 1 }
 | 
						|
 | 
						|
alMPTuneRX OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Receiver frequency [MHz]."
 | 
						|
::= { alMPODU 2 }
 | 
						|
 | 
						|
alMPTX-PWR OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-128) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitter power level [dB]."
 | 
						|
::= { alMPODU 3 }
 | 
						|
 | 
						|
alMPRX-Level OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-128) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal receiver level [dB]."
 | 
						|
::= { alMPODU 4 }
 | 
						|
 | 
						|
alMPTX-PWRAlrm OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),out(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Alarm transmitter power level."
 | 
						|
::= { alMPODU 5 }
 | 
						|
 | 
						|
alMPRX-LevelAlrm OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Alarm signal receiver level."
 | 
						|
::= { alMPODU 6 }
 | 
						|
 | 
						|
alMPMode-TX OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),manual(1),atpc(2) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Mode of power control."
 | 
						|
::= { alMPODU 7 }
 | 
						|
 | 
						|
alMPODU-LB OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"ODU line-loopback."
 | 
						|
::= { alMPODU 8 }
 | 
						|
 | 
						|
alMPTemperature OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Temperature ODU."
 | 
						|
::= { alMPODU 9 }
 | 
						|
 | 
						|
alMPVerSwMW OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..50))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"MW Circuits version."
 | 
						|
::= { alMPODU 10 }
 | 
						|
 | 
						|
alMPSerNumMW OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..50))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"MW Serial Number."
 | 
						|
::= { alMPODU 11 }
 | 
						|
 | 
						|
alMPTypeODU OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),oduA(0),oduB(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Type of ODU."
 | 
						|
::= { alMPODU 12 }
 | 
						|
 | 
						|
alMPPTX OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Set power of transmitter."
 | 
						|
::= { alMPODU 13 }
 | 
						|
 | 
						|
alMPModem     OBJECT IDENTIFIER ::= { alMP 4 }
 | 
						|
 | 
						|
alMPQuality OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Quality of signal."
 | 
						|
::= { alMPModem 1 }
 | 
						|
 | 
						|
alMPSNR OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Signal noise ratio."
 | 
						|
::= { alMPModem 2 }
 | 
						|
 | 
						|
alMPQualityAlrm OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),out(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Alarm quality of signal."
 | 
						|
::= { alMPModem 3 }
 | 
						|
 | 
						|
alMPSNRAlrm OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Alarm signal noise ratio."
 | 
						|
::= { alMPModem 4 }
 | 
						|
 | 
						|
alMPRate OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ndef(0),r300Mbps(1),r200Mbps(2),r16Mbps1(3),r282Mbps(4),r40Mbps1(5),r20Mbps1(6),r10Mbps1(7),r5Mbps1(8),r179Mbps(9),r230Mbps(10),
 | 
						|
                            r14Mbps(11),r32Mbps2(12),r44Mbps(13),r22Mbps(14),r11Mbps(15),r5Mbps(16),r66Mbps(17),r33Mbps(18),
 | 
						|
                            r16Mbps(19),r8Mbps(20),r80Mbps(21),r333Mbps(22),r355Mbps(23),r384Mbps(24),r50Mbps(25),r72Mbps(26),
 | 
						|
                            r100Mbps(27),r123Mbps(28),r158Mbps(29),r168Mbps(30),r77Mbps(31),r35Mbps(32),r25Mbps(33),r165Mbps(34),
 | 
						|
                            r61Mbps(35),r39Mbps(36),r19Mbps(37),r17Mbps(38),r30Mbps(39),r34Mbps(40),r60Mbps(41),r178Mbps(42),
 | 
						|
                            r186Mbps(43),r1250Mbps(44),r70Mbps(45),r58Mbps(46),r116Mbps(47),r149Mbps(48),r183Mbps(49),
 | 
						|
                            r216Mbps(50),r249Mbps(51),r31Mbps(52),r41Mbps(53),r59Mbps(54),r64Mbps(55),r69Mbps(56),
 | 
						|
                            r83Mbps(57),r102Mbps(58),r119Mbps(59),r127Mbps(60),r137Mbps(61),r89Mbps(62) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmision rate of link."
 | 
						|
::= { alMPModem 5 }
 | 
						|
 | 
						|
alMPQAM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ndef(0),mp4FSK(1),mpQPSK(2),mp4QAM1(3),mp8QAM(4),mp16QAM1(5),mp4QAM2(6),mp16QAM2(7),mp32QAM(8),mp64QAM(9),mp128QAM(10),mp256QAM(11) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Low transnission rate of link."
 | 
						|
::= { alMPModem 6 }
 | 
						|
 | 
						|
alMPActiveACM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Activation ACM."
 | 
						|
::= { alMPModem 7 }
 | 
						|
 | 
						|
alMPStatusACM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),normal(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Actual ACM status."
 | 
						|
::= { alMPModem 8 }
 | 
						|
 | 
						|
alMPBW OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ndef(0),
 | 
						|
                                  bw3-5MHz(1),bw5MHz(2),bw7MHz(3),bw7-5MHz(4),bw10MHz(5),bw13-75MHz(6),bw14MHz(7),bw20MHz(8),bw20MHzETSI(9),bw27-5MHz(10),
 | 
						|
                                  bw28MHz(11),bw28MHzACAP(12),bw30MHz(13),bw40MHz(14),bw50MHz(15),bw55MHz(16),bw56MHz(17),bw56ACAPMHz(18),bw80MHz(19),bw110MHz(20),
 | 
						|
                                  bw112MHz(21) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Actual bandwidth."
 | 
						|
::= { alMPModem 9 }
 | 
						|
 | 
						|
alMPMaxRate OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ndef(0),r300Mbps(1),r200Mbps(2),r16Mbps1(3),r282Mbps(4),r40Mbps1(5),r20Mbps1(6),r10Mbps1(7),r5Mbps1(8),r179Mbps(9),r230Mbps(10),
 | 
						|
                            r14Mbps(11),r32Mbps2(12),r44Mbps(13),r22Mbps(14),r11Mbps(15),r5Mbps(16),r66Mbps(17),r33Mbps(18),
 | 
						|
                            r16Mbps(19),r8Mbps(20),r80Mbps(21),r333Mbps(22),r355Mbps(23),r384Mbps(24),r50Mbps(25),r72Mbps(26),
 | 
						|
                            r100Mbps(27),r123Mbps(28),r158Mbps(29),r168Mbps(30),r77Mbps(31),r35Mbps(32),r25Mbps(33),r165Mbps(34),
 | 
						|
                            r61Mbps(35),r39Mbps(36),r19Mbps(37),r17Mbps(38),r30Mbps(39),r34Mbps(40),r60Mbps(41),r178Mbps(42),
 | 
						|
                            r186Mbps(43),r1250Mbps(44),r70Mbps(45),r58Mbps(46),r116Mbps(47),r149Mbps(48),r183Mbps(49),
 | 
						|
                            r216Mbps(50),r249Mbps(51),r31Mbps(52),r41Mbps(53),r59Mbps(54),r64Mbps(55),r69Mbps(56),
 | 
						|
                            r83Mbps(57),r102Mbps(58),r119Mbps(59),r127Mbps(60),r137Mbps(61),r89Mbps(62) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Maximal Transmision rate of link."
 | 
						|
::= { alMPModem 10 }
 | 
						|
 | 
						|
alMPSupply     OBJECT IDENTIFIER ::= { alMP 5 }
 | 
						|
 | 
						|
alMPInput OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),low(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input voltage low."
 | 
						|
::= { alMPSupply 1 }
 | 
						|
 | 
						|
alMPRDG        OBJECT IDENTIFIER ::= { alMP 6 }
 | 
						|
 | 
						|
alMPEEPROM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"EEPROM memory status."
 | 
						|
::= { alMPRDG 1 }
 | 
						|
 | 
						|
alMPRAM OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),bad(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"RAM memory status."
 | 
						|
::= { alMPRDG 2 }
 | 
						|
 | 
						|
alMPCommRMT OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),error(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication status with remote station."
 | 
						|
::= { alMPRDG 3 }
 | 
						|
 | 
						|
alMPMUX        OBJECT IDENTIFIER ::= { alMP 7 }
 | 
						|
 | 
						|
alMPBER OBJECT-TYPE
 | 
						|
	SYNTAX  	DisplayString (SIZE (0..30))
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Value of BER."
 | 
						|
::= { alMPMUX 1 }
 | 
						|
 | 
						|
alMPBER-10E6 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"BER > 10E-6."
 | 
						|
::= { alMPMUX 2 }
 | 
						|
 | 
						|
alMPBER-10E4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),no(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"BER > 10E-4."
 | 
						|
::= { alMPMUX 3 }
 | 
						|
 | 
						|
alMPFrame OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),ok(0),loss(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Frame LOSS."
 | 
						|
::= { alMPMUX 4 }
 | 
						|
 | 
						|
alMPLine1     OBJECT IDENTIFIER ::= { alMP 8 }
 | 
						|
 | 
						|
alMPLOSS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 1."
 | 
						|
::= { alMPLine1 1 }
 | 
						|
 | 
						|
alMPILOSS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 1."
 | 
						|
::= { alMPLine1 2 }
 | 
						|
 | 
						|
alMPAIS1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS to line 1."
 | 
						|
::= { alMPLine1 3 }
 | 
						|
 | 
						|
alMPAISL1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"AIS from line 1."
 | 
						|
::= { alMPLine1 4 }
 | 
						|
 | 
						|
alMPLLB1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Line loopback on line 1."
 | 
						|
::= { alMPLine1 5 }
 | 
						|
 | 
						|
alMPRLB1 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Radio loopback on line 1."
 | 
						|
::= { alMPLine1 6 }
 | 
						|
 | 
						|
alMPLine2     OBJECT IDENTIFIER ::= { alMP 9 }
 | 
						|
 | 
						|
alMPLOSS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 2."
 | 
						|
::= { alMPLine2 1 }
 | 
						|
 | 
						|
alMPILOSS2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 2."
 | 
						|
::= { alMPLine2 2 }
 | 
						|
 | 
						|
alMPLink2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),down(0),up(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Link status line 2."
 | 
						|
::= { alMPLine2 3 }
 | 
						|
 | 
						|
alMPSpeed2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),e10Mbps(0),e100Mbps(1),e1000Mbps(2) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Speed of line 2."
 | 
						|
::= { alMPLine2 4 }
 | 
						|
 | 
						|
alMPType2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),halfduplex(0),fullduplex(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication type of line 2."
 | 
						|
::= { alMPLine2 5 }
 | 
						|
 | 
						|
alMPFlow2 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Flow control of line 2."
 | 
						|
::= { alMPLine2 6 }
 | 
						|
 | 
						|
alMPPktRX2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Received packets count of line 2."
 | 
						|
::= { alMPLine2 7 }
 | 
						|
 | 
						|
alMPByteRX2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Received bytes count of line 2."
 | 
						|
::= { alMPLine2 8 }
 | 
						|
 | 
						|
alMPPktTX2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitted packets count of line 2."
 | 
						|
::= { alMPLine2 9 }
 | 
						|
 | 
						|
alMPByteTX2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitted bytes count of line 2."
 | 
						|
::= { alMPLine2 10 }
 | 
						|
 | 
						|
alMPError2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Error count of line 2."
 | 
						|
::= { alMPLine2 11 }
 | 
						|
 | 
						|
alMPCollision2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Collision count of line 2."
 | 
						|
::= { alMPLine2 12 }
 | 
						|
 | 
						|
alMPPauseIn2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input Pause count of line 2."
 | 
						|
::= { alMPLine2 13 }
 | 
						|
 | 
						|
alMPPauseOut2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Output Pause count of line 2."
 | 
						|
::= { alMPLine2 14 }
 | 
						|
 | 
						|
alMPDiscardsIn2 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input Discards pactets count of line 2."
 | 
						|
::= { alMPLine2 15 }
 | 
						|
 | 
						|
alMPLine3     OBJECT IDENTIFIER ::= { alMP 10 }
 | 
						|
 | 
						|
alMPLOSS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 3."
 | 
						|
::= { alMPLine3 1 }
 | 
						|
 | 
						|
alMPILOSS3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 3."
 | 
						|
::= { alMPLine3 2 }
 | 
						|
 | 
						|
alMPLink3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),down(0),up(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Link status line 3."
 | 
						|
::= { alMPLine3 3 }
 | 
						|
 | 
						|
alMPSpeed3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),e10Mbps(0),e100Mbps(1),e1000Mbps(2) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Speed of line 3."
 | 
						|
::= { alMPLine3 4 }
 | 
						|
 | 
						|
alMPType3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),halfduplex(0),fullduplex(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication type of line 3."
 | 
						|
::= { alMPLine3 5 }
 | 
						|
 | 
						|
alMPFlow3 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Flow control of line 3."
 | 
						|
::= { alMPLine3 6 }
 | 
						|
 | 
						|
alMPPktRX3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Received packets count of line 3."
 | 
						|
::= { alMPLine3 7 }
 | 
						|
 | 
						|
alMPByteRX3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Received bytes count of line 3."
 | 
						|
::= { alMPLine3 8 }
 | 
						|
 | 
						|
alMPPktTX3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitted packets count of line 3."
 | 
						|
::= { alMPLine3 9 }
 | 
						|
 | 
						|
alMPByteTX3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitted bytes count of line 3."
 | 
						|
::= { alMPLine3 10 }
 | 
						|
 | 
						|
alMPError3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Error count of line 3."
 | 
						|
::= { alMPLine3 11 }
 | 
						|
 | 
						|
alMPCollision3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Collision count of line 3."
 | 
						|
::= { alMPLine3 12 }
 | 
						|
 | 
						|
alMPPauseIn3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input Pause count of line 3."
 | 
						|
::= { alMPLine3 13 }
 | 
						|
 | 
						|
alMPPauseOut3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Output Pause count of line 3."
 | 
						|
::= { alMPLine3 14 }
 | 
						|
 | 
						|
alMPDiscardsIn3 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input Discards pactets count of line 3."
 | 
						|
::= { alMPLine3 15 }
 | 
						|
 | 
						|
alMPLine4     OBJECT IDENTIFIER ::= { alMP 11 }
 | 
						|
 | 
						|
alMPLOSS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),not(0),yes(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"LOSS on line 4."
 | 
						|
::= { alMPLine4 1 }
 | 
						|
 | 
						|
alMPILOSS4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Ignore LOSS on line 4."
 | 
						|
::= { alMPLine4 2 }
 | 
						|
 | 
						|
alMPLink4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),down(0),up(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Link status line 4."
 | 
						|
::= { alMPLine4 3 }
 | 
						|
 | 
						|
alMPSpeed4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),e10Mbps(0),e100Mbps(1),e1000Mbps(2) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Speed of line 4."
 | 
						|
::= { alMPLine4 4 }
 | 
						|
 | 
						|
alMPType4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),halfduplex(0),fullduplex(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Communication type of line 4."
 | 
						|
::= { alMPLine4 5 }
 | 
						|
 | 
						|
alMPFlow4 OBJECT-TYPE
 | 
						|
	SYNTAX  	INTEGER { offline(-1),off(0),on(1) }
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Flow control of line 4."
 | 
						|
::= { alMPLine4 6 }
 | 
						|
 | 
						|
alMPPktRX4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Received packets count of line 4."
 | 
						|
::= { alMPLine4 7 }
 | 
						|
 | 
						|
alMPByteRX4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Received bytes count of line 4."
 | 
						|
::= { alMPLine4 8 }
 | 
						|
 | 
						|
alMPPktTX4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitted packets count of line 4."
 | 
						|
::= { alMPLine4 9 }
 | 
						|
 | 
						|
alMPByteTX4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Transmitted bytes count of line 4."
 | 
						|
::= { alMPLine4 10 }
 | 
						|
 | 
						|
alMPError4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Error count of line 4."
 | 
						|
::= { alMPLine4 11 }
 | 
						|
 | 
						|
alMPCollision4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Collision count of line 4."
 | 
						|
::= { alMPLine4 12 }
 | 
						|
 | 
						|
alMPPauseIn4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input Pause count of line 4."
 | 
						|
::= { alMPLine4 13 }
 | 
						|
 | 
						|
alMPPauseOut4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Output Pause count of line 4."
 | 
						|
::= { alMPLine4 14 }
 | 
						|
 | 
						|
alMPDiscardsIn4 OBJECT-TYPE
 | 
						|
	SYNTAX  	Unsigned32
 | 
						|
	ACCESS		read-only
 | 
						|
	STATUS		mandatory
 | 
						|
	DESCRIPTION	"Input Discards pactets count of line 4."
 | 
						|
::= { alMPLine4 15 }
 | 
						|
 | 
						|
END
 |