-- File Name   : SPC200.txt
 | 
						||
 | 
						||
-- Date        : Wed Aug 23 14:03:00 CEST 2006
 | 
						||
-- Author      : Gilles Marceau
 | 
						||
 | 
						||
-- Date        : Tue Jul 06 18:48:54 CEST 2004
 | 
						||
-- Author      : Luc Capanaccia
 | 
						||
 | 
						||
-- Date        : Tue Jul 22 12:00:00 CEST 2004
 | 
						||
-- Reviewed by : Gilles Dupont
 | 
						||
 | 
						||
-- Date        : Mon Sep 13 12:00:00 CEST 2004
 | 
						||
-- Reviewed by : Gilles Dupont
 | 
						||
 | 
						||
-- Date        : Mon Sep 21 12:00:00 CEST 2004
 | 
						||
-- Reviewed by : Gilles Dupont
 | 
						||
 | 
						||
-- Date        : Tue Nov 16 12:30:00 CEST 2004
 | 
						||
-- Reviewed by : Luc Capanaccia
 | 
						||
 | 
						||
-- Date        : Fri Dec 17 12:30:00 CEST 2004
 | 
						||
-- Reviewed by : Luc Capanaccia
 | 
						||
 | 
						||
-- Date        : Thu Sep 15 14:00:00 CEST 2005
 | 
						||
-- Reviewed by : Philippe Rimauro (Tag PR01)
 | 
						||
 | 
						||
-- Date        : Thu Feb 08 14:03:00 CEST 2007
 | 
						||
-- Author      : Gilles Marceau
 | 
						||
 | 
						||
SPC200  DEFINITIONS ::= BEGIN
 | 
						||
        IMPORTS
 | 
						||
                RowStatus, TruthValue, MacAddress, DisplayString, TEXTUAL-CONVENTION
 | 
						||
                        FROM SNMPv2-TC
 | 
						||
                AGENT-CAPABILITIES, OBJECT-GROUP, MODULE-COMPLIANCE
 | 
						||
                        FROM SNMPv2-CONF
 | 
						||
                MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, 
 | 
						||
                Counter32, IpAddress, Unsigned32, Gauge32
 | 
						||
                        FROM SNMPv2-SMI
 | 
						||
                interfaces, ifIndex
 | 
						||
                        FROM IF-MIB                        
 | 
						||
                spidcom 
 | 
						||
                        FROM SPIDCOM-MIB;
 | 
						||
 | 
						||
                spc200MIB       MODULE-IDENTITY
 | 
						||
 | 
						||
                LAST-UPDATED    "200412171230Z" -- December 17, 2004
 | 
						||
 | 
						||
                ORGANIZATION    "Organization"
 | 
						||
                CONTACT-INFO    "Contact-info"
 | 
						||
                DESCRIPTION     "Description"
 | 
						||
                
 | 
						||
                REVISION        "200412171230Z"
 | 
						||
                DESCRIPTION     "Add software upgrade features"
 | 
						||
 | 
						||
                REVISION        "200411161230Z"
 | 
						||
                DESCRIPTION     "Add adapt level table , commit and reset command"
 | 
						||
                                
 | 
						||
                REVISION        "200409211200Z"
 | 
						||
                DESCRIPTION     "Add quick access to channel modulation and pilots"
 | 
						||
                                
 | 
						||
                REVISION        "200409131200Z"
 | 
						||
                DESCRIPTION     "Add quick access to notches"
 | 
						||
 | 
						||
                REVISION        "200407221200Z"
 | 
						||
                DESCRIPTION     "Corrected compilation errors"
 | 
						||
 | 
						||
                REVISION        "200407011757Z"
 | 
						||
                DESCRIPTION     "Initial revision"
 | 
						||
           
 | 
						||
                ::=  {  spidcom  1  }
 | 
						||
 | 
						||
-- TEXTUAL-CONVENTIONS --
 | 
						||
        ModulationValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "Modulation amplitude used by a group of carriers."
 | 
						||
                SYNTAX                  INTEGER  { none ( 1 ) , 
 | 
						||
                                                   bpsk ( 2 ) , 
 | 
						||
                                                   qpsk ( 3 )  , 
 | 
						||
                                                   qam16 ( 4 ) , 
 | 
						||
                                                   qam64 ( 5 ) , 
 | 
						||
                                                   qam256 ( 6 ) } 
 | 
						||
 | 
						||
        CarrierValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "A group is composed of 8 carriers."
 | 
						||
                SYNTAX                  Integer32  ( 1 .. 8  ) 
 | 
						||
 | 
						||
        PilotValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "The pilot carrier wave can be chosen between 
 | 
						||
                        the carrier 1 up to carrier 128 inside a band carrier range."
 | 
						||
                SYNTAX                  Integer32  ( 1 .. 128  ) 
 | 
						||
 | 
						||
        BandValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "A channel is composed of 7 bands."
 | 
						||
                SYNTAX                  Integer32  ( 1 .. 7  ) 
 | 
						||
 | 
						||
        PlcChannelType ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "The different type of plc channels:
 | 
						||
                          rx for the current reception channel,
 | 
						||
                          rx last for the last reception channel,
 | 
						||
                          tx for the current transmission channel."
 | 
						||
                SYNTAX                  INTEGER  { rx ( 1 ) , 
 | 
						||
                                                   rxLast ( 2 ) , 
 | 
						||
                                                   tx ( 3 ) } 
 | 
						||
 | 
						||
        EstimationMode ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "The type of Channel estimation process. Two are available:
 | 
						||
                          - automatic, the equipment negociates the best configuration
 | 
						||
                            with the remote equipment,
 | 
						||
                          - manual, the operator defines the configuration."
 | 
						||
                SYNTAX                  INTEGER  { automatic ( 1 ) , 
 | 
						||
                                                   manual ( 2 ) } 
 | 
						||
 | 
						||
        GroupValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "A band is composed of 16 groups."
 | 
						||
                SYNTAX                  Integer32  ( 1 .. 16  ) 
 | 
						||
 | 
						||
        ResultValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "Result value of input vectors."
 | 
						||
                SYNTAX                  INTEGER  { success ( 1 ) , 
 | 
						||
                                                   fail ( 2 ) } 
 | 
						||
                                                   
 | 
						||
        AdaptValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "The adapt level integer value."
 | 
						||
                SYNTAX                  Integer32  ( 0 .. 8191  )
 | 
						||
           
 | 
						||
        ChannelBandwidthValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "The channel bandwidth integer value."
 | 
						||
                SYNTAX                  Integer32 --PR01
 | 
						||
                
 | 
						||
        SoftwareIndex ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "The software index."
 | 
						||
                SYNTAX                  Integer32  ( 1 .. 10  )
 | 
						||
                                                                   
 | 
						||
        SoftwareActionResultValue ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "Result value of software action process."
 | 
						||
                SYNTAX                  INTEGER  { success ( 0 ) , 
 | 
						||
                                                   on-going ( 1 ) ,
 | 
						||
                                                   fileNotExist ( 2 ) ,
 | 
						||
                                                   flashExhausted ( 3 ),
 | 
						||
                                                   flashCorrupted ( 4 ),
 | 
						||
                                                   notEnoughMemory ( 5 ),
 | 
						||
                                                   invalidParameter ( 6 ),
 | 
						||
                                                   genericError ( 7 ) } 
 | 
						||
                                                   
 | 
						||
        SoftwareActionType ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "Type of software management action."
 | 
						||
                SYNTAX                  INTEGER  { switch ( 1 ) , 
 | 
						||
                                                   remove ( 2 ) } 
 | 
						||
                                                       
 | 
						||
--PR01 BEGIN
 | 
						||
       PlcModeType ::= TEXTUAL-CONVENTION 
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION
 | 
						||
                        "Type of software management action."
 | 
						||
                SYNTAX                  INTEGER  { ad-hoc ( 0 ) , 
 | 
						||
                                                   slave  ( 1 ) ,
 | 
						||
                                                   master ( 2 ) } 
 | 
						||
--PR01 END
 | 
						||
 | 
						||
-- PLC data
 | 
						||
 | 
						||
        plc OBJECT IDENTIFIER
 | 
						||
                ::=  {  spc200MIB  1  }
 | 
						||
 | 
						||
-- statistic data
 | 
						||
 | 
						||
        stats OBJECT IDENTIFIER
 | 
						||
                ::=  {  plc  1  }
 | 
						||
--PR01 BEGIN                
 | 
						||
--        protocol OBJECT IDENTIFIER
 | 
						||
--                ::=  {  stats  1  }
 | 
						||
 | 
						||
--        ip      OBJECT IDENTIFIER
 | 
						||
--                ::=  {  protocol  1  }
 | 
						||
 | 
						||
--        mac     OBJECT IDENTIFIER
 | 
						||
--                ::=  {  protocol  2  }
 | 
						||
 | 
						||
--        plcp    OBJECT IDENTIFIER
 | 
						||
--                ::=  {  protocol  3  }
 | 
						||
 | 
						||
--        ipStatsTable OBJECT-TYPE
 | 
						||
--                SYNTAX          SEQUENCE  OF  IpStatsEntry
 | 
						||
--                MAX-ACCESS      not-accessible
 | 
						||
--                STATUS          current
 | 
						||
--                DESCRIPTION     "This table gathers all statistic data specific to 
 | 
						||
--                                SPC200 chip relative to IP protocol. The data is 
 | 
						||
--                                relative to the underlying interface that is under 
 | 
						||
--                                the IP protocol layer. So the table index is 
 | 
						||
--                                the ifIndex of such an interface."
 | 
						||
--                ::=  { ip  1 }
 | 
						||
 | 
						||
--        ipStatsEntry OBJECT-TYPE
 | 
						||
--                SYNTAX          IpStatsEntry
 | 
						||
--                MAX-ACCESS      not-accessible
 | 
						||
--                STATUS          current
 | 
						||
--                DESCRIPTION     "This row contains IP statistic data specific to 
 | 
						||
--                                SPC200  chip. The data is relevant for the interface 
 | 
						||
--                                under the IP protocol layer."
 | 
						||
--                INDEX           {  ifIndex  }
 | 
						||
--                ::=  { ipStatsTable 1 }
 | 
						||
 | 
						||
--        IpStatsEntry  ::=  SEQUENCE {
 | 
						||
--                ipInPkts  Counter32,
 | 
						||
--                ipInErrorPkts  Counter32,
 | 
						||
--                ipOutPkts  Counter32,
 | 
						||
--                ipOutErrorPkts  Counter32,
 | 
						||
--                ipInBridgedPkts  Counter32
 | 
						||
--                }
 | 
						||
 | 
						||
 | 
						||
--        ipInPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of IP packets received by the interface 
 | 
						||
--                                        associated with this entry"
 | 
						||
--                ::=  {  ipStatsEntry  1  }
 | 
						||
 | 
						||
 | 
						||
--        ipInErrorPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of inbound IP packets that contained 
 | 
						||
--                                        errors preventing them from being deliverable to a
 | 
						||
--                                        higher -layer protocol on the interface associated
 | 
						||
--                                        with this entry."
 | 
						||
--                ::=  {  ipStatsEntry  2  }
 | 
						||
 | 
						||
 | 
						||
--        ipOutPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of outbound IP packets transmitted 
 | 
						||
--                                        out the interface associated with this entry"
 | 
						||
--                ::=  {  ipStatsEntry  3  }
 | 
						||
 | 
						||
 | 
						||
--        ipOutErrorPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of outbound IP packets that could not be
 | 
						||
--                                        transmitted because of errors."
 | 
						||
--                ::=  {  ipStatsEntry  4  }
 | 
						||
 | 
						||
 | 
						||
--        ipInBridgedPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of IP packets bridged from the interface,
 | 
						||
--                                        associated with this entry, and another one"
 | 
						||
--                ::=  {  ipStatsEntry  5  }
 | 
						||
 | 
						||
--        ipInPackets OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of IP packets received 
 | 
						||
--                                        by the SPC200 CHIP"
 | 
						||
--                ::=  {  ip  2  }
 | 
						||
 | 
						||
--        ipInErrorPackets OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of inbound IP packets that 
 | 
						||
--                                        contained errors preventing them from being delivered."
 | 
						||
--                ::=  {  ip  3  }
 | 
						||
 | 
						||
--        ipOutPackets OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of outbound IP packets transmitted 
 | 
						||
--                                        out the interfaces"
 | 
						||
--                ::=  {  ip  4  }
 | 
						||
 | 
						||
--        ipOutErrorPackets OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of outbound IP packets that could 
 | 
						||
--                                        not be transmitted because of errors."
 | 
						||
--                ::=  {  ip  5  }
 | 
						||
 | 
						||
--        ipBridgedPackets OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of IP packets bridged"
 | 
						||
--                ::=  {  ip  6  }
 | 
						||
 | 
						||
--        macStatsTable OBJECT-TYPE
 | 
						||
--                SYNTAX          SEQUENCE  OF  MacStatsEntry
 | 
						||
--                MAX-ACCESS      not-accessible
 | 
						||
--                STATUS          current
 | 
						||
--                DESCRIPTION     "This table gathers all SPC200 chip specific packet 
 | 
						||
--                                statistics relative to MAC layer.
 | 
						||
--                                The data is relative to the underlying interface 
 | 
						||
--                                that is under the MAC layer. So the table index is
 | 
						||
--                                the ifIndex of such an interface."
 | 
						||
--                ::=  { mac  1 }
 | 
						||
 | 
						||
--        macStatsEntry OBJECT-TYPE
 | 
						||
--                SYNTAX          MacStatsEntry
 | 
						||
--                MAX-ACCESS      not-accessible
 | 
						||
--                STATUS          current
 | 
						||
--                DESCRIPTION     "This row contains MAC statistic data specific 
 | 
						||
--                                to SPC200 chip. The data is relevant for the interface
 | 
						||
--                                under the MAC layer."
 | 
						||
--                INDEX           {  ifIndex  }
 | 
						||
--                ::=  { macStatsTable 1 }
 | 
						||
--
 | 
						||
--        MacStatsEntry  ::=  SEQUENCE {
 | 
						||
--                macInPkts  Counter32,
 | 
						||
--                macInErrorPkts  Counter32,
 | 
						||
--                macOutPackets  Counter32,
 | 
						||
--                macOutErrorPkts  Counter32
 | 
						||
--                }
 | 
						||
 | 
						||
 | 
						||
--        macInPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of MAC  packets received by the interface 
 | 
						||
--                                        associated with this entry"
 | 
						||
--                ::=  {  macStatsEntry  1  }
 | 
						||
--
 | 
						||
--
 | 
						||
--        macInErrorPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of inbound MAC packets that contained 
 | 
						||
--                                        errors preventing them from being deliverable to 
 | 
						||
--                                        a higher -layer protocol on the interface
 | 
						||
--                                        associated with this entry."
 | 
						||
--                ::=  {  macStatsEntry  2  }
 | 
						||
 | 
						||
 | 
						||
--        macOutPackets OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of outbound MAC packets transmitted
 | 
						||
--                                        out the interface associated with this entry"
 | 
						||
--                ::=  {  macStatsEntry  3  }
 | 
						||
 | 
						||
 | 
						||
--        macOutErrorPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of outbound MAC packets that could not be
 | 
						||
--                                        transmitted because of errors."
 | 
						||
--                ::=  {  macStatsEntry  4  }
 | 
						||
 | 
						||
--        plcpStatsTable OBJECT-TYPE
 | 
						||
--                SYNTAX          SEQUENCE  OF  PlcpStatsEntry
 | 
						||
--                MAX-ACCESS      not-accessible
 | 
						||
--                STATUS          current
 | 
						||
--                DESCRIPTION     "This table gathers all SPC200 chip specific packet 
 | 
						||
--                                statistics relative to PLCP protocol.
 | 
						||
--                                The data is relative to the underlying interface that
 | 
						||
--                                is under the PLCP protocol layer. So the table index 
 | 
						||
--                                is the ifIndex of such an interface."
 | 
						||
--                ::=  { plcp  1 }
 | 
						||
 | 
						||
--        plcpStatsEntry OBJECT-TYPE
 | 
						||
--                SYNTAX          PlcpStatsEntry
 | 
						||
--                MAX-ACCESS      not-accessible
 | 
						||
--                STATUS          current
 | 
						||
--                DESCRIPTION     "This row contains PLCP statistic data specific 
 | 
						||
--                                to SPC200 chip. The data is relevant for the interface
 | 
						||
--                                under the PLCP layer."
 | 
						||
--                INDEX           {  ifIndex  }
 | 
						||
--                ::=  { plcpStatsTable 1 }
 | 
						||
 | 
						||
--        PlcpStatsEntry  ::=  SEQUENCE {
 | 
						||
--                plcpInPkts  Counter32,
 | 
						||
--                plcpInErrorPkts  Counter32,
 | 
						||
--                plcpOutPkts  Counter32,
 | 
						||
--                plcpOutErrorPkts  Counter32
 | 
						||
--                }
 | 
						||
 | 
						||
 | 
						||
--       plcpInPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of PLCP packets received by the interface
 | 
						||
--                                        associated with this entry"
 | 
						||
--                ::=  {  plcpStatsEntry  1  }
 | 
						||
 | 
						||
 | 
						||
--        plcpInErrorPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of inbound PLCP packets that contained 
 | 
						||
--                                        errors preventing them from being deliverable to a
 | 
						||
--                                        higher -layer protocol on the interface associated 
 | 
						||
--                                        with this entry."
 | 
						||
--                ::=  {  plcpStatsEntry  2  }
 | 
						||
 | 
						||
 | 
						||
--        plcpOutPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The total number of outbound PLCP packets transmitted
 | 
						||
--                                        out the interface associated with this entry"
 | 
						||
--                ::=  {  plcpStatsEntry  3  }
 | 
						||
 | 
						||
 | 
						||
--        plcpOutErrorPkts OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The number of outbound PLCP packets that could not be
 | 
						||
--                                        transmitted because of errors."
 | 
						||
--                ::=  {  plcpStatsEntry  4  }
 | 
						||
--PR01 END                
 | 
						||
 | 
						||
 | 
						||
        portStatsTable OBJECT-TYPE
 | 
						||
                SYNTAX          SEQUENCE  OF  PortStatsEntry
 | 
						||
                MAX-ACCESS      not-accessible
 | 
						||
                STATUS          current
 | 
						||
                DESCRIPTION     "This table gathers all statistic data specific 
 | 
						||
                                to SPC200 chip relative to plc connection."
 | 
						||
                ::=  { stats  2 }
 | 
						||
 | 
						||
        portStatsEntry OBJECT-TYPE
 | 
						||
                SYNTAX          PortStatsEntry
 | 
						||
                MAX-ACCESS      not-accessible
 | 
						||
                STATUS          current
 | 
						||
                DESCRIPTION     "This row contains statistic data specific to 
 | 
						||
                                SPC200 chip  relative to a connection."
 | 
						||
                INDEX           {  plcBasePortIndex,
 | 
						||
                                   portStatsBandIndex,
 | 
						||
                                   portStatsGroupIndex,
 | 
						||
                                   portStatsCarrierIndex }
 | 
						||
                ::=  { portStatsTable 1 }
 | 
						||
 | 
						||
        PortStatsEntry  ::=  SEQUENCE {
 | 
						||
                portStatsBandIndex  BandValue,
 | 
						||
                portStatsGroupIndex  GroupValue,
 | 
						||
                portStatsCarrierIndex  CarrierValue,
 | 
						||
                portStatsSignal Counter32,
 | 
						||
                portStatsNoise  Counter32
 | 
						||
--                portStatsBer Counter32
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        portStatsBandIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the signal, 
 | 
						||
                                        noise, ber data are collected."
 | 
						||
                ::=  {  portStatsEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        portStatsGroupIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  GroupValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The group number on which the signal, 
 | 
						||
                                        noise, ber data are collected"
 | 
						||
                ::=  {  portStatsEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        portStatsCarrierIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  CarrierValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The group number on which the signal, 
 | 
						||
                                        noise, ber data are collected"
 | 
						||
                ::=  {  portStatsEntry  3  }
 | 
						||
 | 
						||
 | 
						||
        portStatsSignal OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The DB value of the signal associated 
 | 
						||
                                        with the carrier wave entry."
 | 
						||
                ::=  {  portStatsEntry  4  }
 | 
						||
 | 
						||
 | 
						||
        portStatsNoise OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The DB value of the noise associated 
 | 
						||
                                        with the carrier wave entry."
 | 
						||
                ::=  {  portStatsEntry  5  }
 | 
						||
--PR01 BEGIN
 | 
						||
--        portStatsBer OBJECT-TYPE     
 | 
						||
--                SYNTAX                  Counter32
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The BER value * 100 associated 
 | 
						||
--                                        with the carrier wave entry."
 | 
						||
--                ::=  {  portStatsEntry  6  }
 | 
						||
--PR01 END
 | 
						||
 | 
						||
        portStats2Table OBJECT-TYPE
 | 
						||
                SYNTAX          SEQUENCE  OF  PortStats2Entry
 | 
						||
                MAX-ACCESS      not-accessible
 | 
						||
                STATUS          current
 | 
						||
                DESCRIPTION     "This table gathers all statistic data specific to 
 | 
						||
                                SPC200 chip relative to plc channels. This table has 
 | 
						||
                                the same information as the portChannelStatsTable 
 | 
						||
                                but in a more compact way. This table has been added 
 | 
						||
                                to deal with possible slow performances."
 | 
						||
                ::=  { stats  3 }
 | 
						||
 | 
						||
        portStats2Entry OBJECT-TYPE
 | 
						||
                SYNTAX          PortStats2Entry
 | 
						||
                MAX-ACCESS      not-accessible
 | 
						||
                STATUS          current
 | 
						||
                DESCRIPTION     "This row contains statistic data specific to 
 | 
						||
                                SPC200 chip  relative to a connection."
 | 
						||
                INDEX           {  plcBasePortIndex,
 | 
						||
                                   plcModBandIndex  }
 | 
						||
                ::=  { portStats2Table 1        }
 | 
						||
 | 
						||
        PortStats2Entry ::=  SEQUENCE {
 | 
						||
                portStats2Signal     OCTET STRING,
 | 
						||
                portStats2Noise      OCTET STRING,
 | 
						||
 | 
						||
 | 
						||
--PR01 BEGIN
 | 
						||
--                portStats2Ber        OCTET STRING,
 | 
						||
                portStats2AvgBandAtt Counter32,
 | 
						||
                portStats2AvgBandSNR Counter32
 | 
						||
--PR01 END
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        portStats2Signal OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The values of the signal for all the carrier waves. 
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE. 
 | 
						||
                                        Each value is coded on two bytes. 
 | 
						||
                                        There is one value for each 128 carriers of the 
 | 
						||
                                        considered band."
 | 
						||
                ::=  {  portStats2Entry 1  }
 | 
						||
 | 
						||
 | 
						||
        portStats2Noise OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The values of the noise for all the carrier waves. 
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is coded on two bytes. 
 | 
						||
                                        There is one value for each 128 carriers of the 
 | 
						||
                                        considered band."
 | 
						||
                ::=  {  portStats2Entry 2  }
 | 
						||
 | 
						||
--        portStats2Ber OBJECT-TYPE     
 | 
						||
--                SYNTAX                  OCTET STRING
 | 
						||
--                MAX-ACCESS              read-only
 | 
						||
--                STATUS                  current
 | 
						||
--                DESCRIPTION             "The values of the signal for all the carrier waves. 
 | 
						||
--                                        The expected format is VALUE VALUE VALUE ... VALUE. 
 | 
						||
--                                        Each value is coded on two bytes. 
 | 
						||
--                                        There is one value for each 128 carriers of the 
 | 
						||
--                                        considered band.
 | 
						||
--                                        The VALUE represents the BER value * 10000."
 | 
						||
--                ::=  {  portStats2Entry 3  }
 | 
						||
 | 
						||
--PR01 BEGIN
 | 
						||
       portStats2AvgBandAtt OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Average attenuation per band (dB)." 
 | 
						||
                ::=  {  portStats2Entry  3  }
 | 
						||
 | 
						||
 | 
						||
        portStats2AvgBandSNR OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Average SNR per band (dB)."
 | 
						||
                ::=  {  portStats2Entry  4  }
 | 
						||
--PR01 END
 | 
						||
--PR01 BEGIN
 | 
						||
        portStats3Table OBJECT-TYPE
 | 
						||
                SYNTAX          SEQUENCE  OF  PortStats3Entry
 | 
						||
                MAX-ACCESS      not-accessible
 | 
						||
                STATUS          current
 | 
						||
                DESCRIPTION     "This table gathers all statistic data specific to 
 | 
						||
                                SPC200 chip relative to plc channels. This table has 
 | 
						||
                                the same information as the portChannelStatsTable 
 | 
						||
                                but in a more compact way. This table has been added 
 | 
						||
                                to deal with possible slow performances."
 | 
						||
                ::=  { stats  4 }
 | 
						||
 | 
						||
        portStats3Entry OBJECT-TYPE
 | 
						||
                SYNTAX          PortStats3Entry
 | 
						||
                MAX-ACCESS      not-accessible
 | 
						||
                STATUS          current
 | 
						||
                DESCRIPTION     "This row contains statistic data specific to 
 | 
						||
                                SPC200 chip  relative to a connection."
 | 
						||
                INDEX           {  plcBasePortIndex  }
 | 
						||
                ::=  { portStats3Table 1 }
 | 
						||
 | 
						||
        PortStats3Entry ::=  SEQUENCE {
 | 
						||
                portStats3AvgAtt      Counter32,
 | 
						||
                portStats3AvgSNR      Counter32
 | 
						||
                }
 | 
						||
 | 
						||
       portStats3AvgAtt OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Average attenuation on the link (dB)." 
 | 
						||
                ::=  {  portStats3Entry 1  }
 | 
						||
 | 
						||
       portStats3AvgSNR OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Average SNR on the link (dB)." 
 | 
						||
                ::=  {  portStats3Entry 2  }                            
 | 
						||
                         
 | 
						||
	   bootstats OBJECT-IDENTITY
 | 
						||
                STATUS  current
 | 
						||
                DESCRIPTION   "boot statistics"
 | 
						||
                ::= { stats 5 }
 | 
						||
 | 
						||
	   bootstatsBoot OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Boot"
 | 
						||
                ::=  { bootstats 1 }
 | 
						||
       
 | 
						||
	   bootstatsManualReset OBJECT-TYPE     
 | 
						||
       			SYNTAX                  Counter32
 | 
						||
		        MAX-ACCESS              read-only
 | 
						||
		        STATUS                  current
 | 
						||
		        DESCRIPTION             "Manual reset"
 | 
						||
		        ::=  { bootstats 2 }
 | 
						||
       
 | 
						||
	   bootstatsFailureReset OBJECT-TYPE     
 | 
						||
 	            SYNTAX                  Counter32
 | 
						||
		        MAX-ACCESS              read-only
 | 
						||
		        STATUS                  current
 | 
						||
		        DESCRIPTION             "Failure reset"
 | 
						||
		        ::=  { bootstats 3 }              
 | 
						||
                            
 | 
						||
--PR01 END
 | 
						||
                
 | 
						||
-- configuration data
 | 
						||
        plcObjects OBJECT IDENTIFIER
 | 
						||
                ::=  {  plc  2  }
 | 
						||
 | 
						||
        plcMode OBJECT-TYPE     -- PR01
 | 
						||
                SYNTAX                  PlcModeType --PR01
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Plc Mode"
 | 
						||
                ::=  {  plcObjects  1  }
 | 
						||
 | 
						||
        plcTopo OBJECT IDENTIFIER
 | 
						||
                ::=  {  plcObjects  2  }
 | 
						||
 | 
						||
        plcNodeConfiguration OBJECT IDENTIFIER
 | 
						||
                ::=  {  plcObjects  3  }
 | 
						||
 | 
						||
--PR01 BEGIN
 | 
						||
         plcSNAnalyser OBJECT IDENTIFIER 
 | 
						||
                ::= { plcObjects  4 }
 | 
						||
 | 
						||
         plcSNAnalyserEnable OBJECT-TYPE     
 | 
						||
                SYNTAX                  INTEGER { true ( 1 ) , 
 | 
						||
                                                  false ( 2 )  }
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "true if the modem should turn to spectrum analyser mode.
 | 
						||
                                        In this mode the modem enters a receive only mode,
 | 
						||
                                        and captures periodic samples of the signal on the powerline.
 | 
						||
                                        The spectrum analyser mode shall be disabled for normal
 | 
						||
                                        powerline modem operation."
 | 
						||
                ::=  {  plcSNAnalyser 1  }
 | 
						||
 | 
						||
         plcSNAnalyserTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcSNAnalyserEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table gathers all statistic data specific to 
 | 
						||
                                        SPC200 chip relative to plc analyser."
 | 
						||
                ::=  { plcSNAnalyser  2 }
 | 
						||
 | 
						||
        plcSNAnalyserEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcSNAnalyserEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains statistic data specific to 
 | 
						||
                                        SPC200 chip relative to a band."
 | 
						||
                INDEX                   {  plcModBandIndex   }
 | 
						||
                ::=  { plcSNAnalyserTable 1 }
 | 
						||
 | 
						||
        PlcSNAnalyserEntry  ::=  SEQUENCE {
 | 
						||
                plcSNAnalyserMinSignal    OCTET STRING,
 | 
						||
                plcSNAnalyserMaxSignal    OCTET STRING,
 | 
						||
                plcSNAnalyserAvgSignal    OCTET STRING,
 | 
						||
                plcSNAnalyserLastSignal   OCTET STRING,
 | 
						||
                plcSNAnalyserFFTDiv       Counter32     
 | 
						||
                 }
 | 
						||
 | 
						||
        plcSNAnalyserMinSignal OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Minimum signal measured over several samples for the
 | 
						||
                                        associated carrier wave entry. The value is expressed
 | 
						||
                                        in Glomer<65> which can be converted in dBm/Hz using the
 | 
						||
                                        following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
 | 
						||
                ::=  {  plcSNAnalyserEntry 1  }
 | 
						||
 | 
						||
 | 
						||
        plcSNAnalyserMaxSignal OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Maximum signal measured on several samples for the
 | 
						||
                                        associated carrier wave entry. The value is expressed
 | 
						||
                                        in Glomer<65> which can be converted in dBm/Hz using the
 | 
						||
                                        following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
 | 
						||
                ::=  {  plcSNAnalyserEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcSNAnalyserAvgSignal OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Average signal measured on several samples for the
 | 
						||
                                        associated carrier wave entry. The value is expressed
 | 
						||
                                        in Glomer<65> which can be converted in dBm/Hz using the
 | 
						||
                                        following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
 | 
						||
                ::=  {  plcSNAnalyserEntry  3  }
 | 
						||
 | 
						||
        plcSNAnalyserLastSignal OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Signal measured for last sample on the associated
 | 
						||
                                        carrier wave entry. The value is expressed
 | 
						||
                                        in Glomer<65> which can be converted in dBm/Hz using the
 | 
						||
                                        following formula: dBm/Hz = 19*log10(Glomer<65>) - 113"
 | 
						||
                ::=  {  plcSNAnalyserEntry  4  }
 | 
						||
 | 
						||
        plcSNAnalyserFFTDiv OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "FFT division factor on the associated band."
 | 
						||
                ::=  {  plcSNAnalyserEntry 5  }
 | 
						||
 | 
						||
        plcSNAnalyserAGC OBJECT-TYPE
 | 
						||
                SYNTAX                  Integer32 ( 0..255 )
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Gain factor in dB, as used by the
 | 
						||
                                        Automatic Gain Control last sample"
 | 
						||
                ::=  {  plcSNAnalyser 3  }
 | 
						||
 | 
						||
 | 
						||
         plcAGCAnalyser OBJECT IDENTIFIER 
 | 
						||
                ::= { plcObjects  5 }
 | 
						||
 | 
						||
         plcAGCAnalyserEnable OBJECT-TYPE     
 | 
						||
                SYNTAX                  INTEGER { true ( 1 ) , 
 | 
						||
                                                  false ( 2 )  }
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             " "
 | 
						||
                ::=  {  plcAGCAnalyser  1  }
 | 
						||
 | 
						||
        plcAGCAnalyserSamplesPart1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             " "
 | 
						||
                ::=  {  plcAGCAnalyser  2  }
 | 
						||
 | 
						||
        plcAGCAnalyserSamplesPart2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             " "
 | 
						||
                ::=  {  plcAGCAnalyser  3  }
 | 
						||
--PR01 END
 | 
						||
 | 
						||
        plcTopoChanges OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The total number of topology changes detected 
 | 
						||
                                        by this plc bridge since the management entity 
 | 
						||
                                        was last reset or initialized. Such changes 
 | 
						||
                                        concerns only 
 | 
						||
                                        - the plcBasePortTable rows 
 | 
						||
                                        - the plcBasePortTable columns 
 | 
						||
                                        except for plcBasePortChannelEstimation"
 | 
						||
                ::=  {  plcTopo  1  }
 | 
						||
 | 
						||
        plcBasePortTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcBasePortEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains the list of plc remote connection"
 | 
						||
                ::=  { plcTopo  2 }
 | 
						||
 | 
						||
        plcBasePortEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcBasePortEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains plc remote connection information"
 | 
						||
                INDEX                   {  plcBasePortIndex  }
 | 
						||
                ::=  { plcBasePortTable 1 }
 | 
						||
 | 
						||
        PlcBasePortEntry  ::=  SEQUENCE {
 | 
						||
                plcBasePortIndex                MacAddress,
 | 
						||
                plcBasePortAddress              MacAddress,
 | 
						||
                plcBasePortChannelEstimation    EstimationMode,
 | 
						||
                plcBasePortAttenuation          Counter32  }
 | 
						||
 | 
						||
 | 
						||
        plcBasePortIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  MacAddress
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The MAC address of the MAC layer above 
 | 
						||
                                        the plc interface of the remote PLC equipment."
 | 
						||
                ::=  {  plcBasePortEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        plcBasePortAddress OBJECT-TYPE     
 | 
						||
                SYNTAX                  MacAddress
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The MAC address of the MAC layer above 
 | 
						||
                                        the plc interface of the remote PLC equipment."
 | 
						||
                ::=  {  plcBasePortEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcBasePortChannelEstimation    OBJECT-TYPE     
 | 
						||
                SYNTAX                  EstimationMode
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Enable or disable the automatic channel 
 | 
						||
                                        estimation processus."
 | 
						||
                ::=  {  plcBasePortEntry  3  }                     
 | 
						||
                
 | 
						||
		plcBasePortAttenuation			OBJECT-TYPE     
 | 
						||
                SYNTAX                  Counter32 
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Link attenuation (dB)."
 | 
						||
                ::=  {  plcBasePortEntry  4 }       
 | 
						||
 | 
						||
 | 
						||
        plcChannelModulationStringTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcChannelModulationStringEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains string values for a quick access to
 | 
						||
                                        the modulation amplitude configurations of all active
 | 
						||
                                        channels."
 | 
						||
                ::=  { plcTopo  3 }
 | 
						||
 | 
						||
 | 
						||
        plcChannelModulationStringEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcChannelModulationStringEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains string values for a quick access to 
 | 
						||
                                        the modulation amplitude configuration
 | 
						||
                                        of each active channel of the remote 
 | 
						||
                                        connection referenced by plcBasePortIndex."
 | 
						||
                INDEX                   { plcBasePortIndex }
 | 
						||
                ::=  { plcChannelModulationStringTable 1 }
 | 
						||
 | 
						||
 | 
						||
                PlcChannelModulationStringEntry  ::=  SEQUENCE {
 | 
						||
                plcRxChannelModulation          OCTET STRING,
 | 
						||
                plcRxLastChannelModulation      OCTET STRING,
 | 
						||
                plcTxChannelModulation          OCTET STRING }
 | 
						||
 | 
						||
 | 
						||
        plcRxChannelModulation OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude values for the Rx channel of 
 | 
						||
                                        a given remote connection entry.
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is an octet representing two modulation values.
 | 
						||
                                        Each modulation is coded on 4 bits.
 | 
						||
                                        There are ( 16 groups * 7 bands ) / 2 = 66 values."
 | 
						||
                ::=  {  plcChannelModulationStringEntry 1  }
 | 
						||
 | 
						||
 | 
						||
        plcRxLastChannelModulation OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude values for the Rx Last channel of 
 | 
						||
                                        a given remote connection entry.
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is an octet representing two modulation values.
 | 
						||
                                        Each modulation is coded on 4 bits representing ModulationValue - 1.
 | 
						||
                                        There are ( 16 groups * 7 bands ) / 2 = 66 values."
 | 
						||
                ::=  {  plcChannelModulationStringEntry 2  }
 | 
						||
 | 
						||
        plcTxChannelModulation OBJECT-TYPE
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude values for the Tx channel of 
 | 
						||
                                        a given remote connection entry.
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is an octet representing two modulation values.
 | 
						||
                                        Each modulation is coded on 4 bits.
 | 
						||
                                        There are ( 16 groups * 7 bands ) / 2 = 66 values."
 | 
						||
                ::=  { plcChannelModulationStringEntry  3 }
 | 
						||
 | 
						||
 | 
						||
        plcChannelModulationTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcChannelModulationEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains the modulation amplitude 
 | 
						||
                                        configuration of all active channels."
 | 
						||
                ::=  { plcTopo  4 }
 | 
						||
 | 
						||
 | 
						||
       plcChannelModulationEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcChannelModulationEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains modulation amplitude configuration
 | 
						||
                                        of the channel, referenced by the plcPortChannelIndex, 
 | 
						||
                                        of the remote connection referenced by 
 | 
						||
                                        plcBasePortIndex."
 | 
						||
                INDEX                   { plcBasePortIndex, 
 | 
						||
                                        plcPortChannelIndex,
 | 
						||
                                        plcModBandIndex  }
 | 
						||
                ::=  { plcChannelModulationTable 1 }
 | 
						||
 | 
						||
        PlcChannelModulationEntry  ::=  SEQUENCE {
 | 
						||
                plcModBandIndex         BandValue,
 | 
						||
                plcModGroup1            ModulationValue,
 | 
						||
                plcModGroup2            ModulationValue,
 | 
						||
                plcModGroup3            ModulationValue,
 | 
						||
                plcModGroup4            ModulationValue,
 | 
						||
                plcModGroup5            ModulationValue,
 | 
						||
                plcModGroup6            ModulationValue,
 | 
						||
                plcModGroup7            ModulationValue,
 | 
						||
                plcModGroup8            ModulationValue,
 | 
						||
                plcModGroup9            ModulationValue,
 | 
						||
                plcModGroup10           ModulationValue,
 | 
						||
                plcModGroup11           ModulationValue,
 | 
						||
                plcModGroup12           ModulationValue,
 | 
						||
                plcModGroup13           ModulationValue,
 | 
						||
                plcModGroup14           ModulationValue,
 | 
						||
                plcModGroup15           ModulationValue,
 | 
						||
                plcModGroup16           ModulationValue
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        plcModBandIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number of which the modulations are defined"
 | 
						||
                ::=  {  plcChannelModulationEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the first group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the second group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  3  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup3 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the third group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  4  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup4 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the fourth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  5  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup5 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the fifth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  6  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup6 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the sixth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  7  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup7 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the seventh group 
 | 
						||
                                         of the band entry of the channel entry 
 | 
						||
                                         for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  8  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup8 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the eighth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  9  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup9 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the nineth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  10  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup10 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the tenth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  11  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup11 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the eleventh group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  12  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup12 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the twelveth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  13  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup13 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the thirteenth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  14  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup14 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the fourteenth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  15  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup15 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the fifteenth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  16  }
 | 
						||
 | 
						||
 | 
						||
        plcModGroup16 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The modulation amplitude of the sixteenth group 
 | 
						||
                                        of the band entry of the channel entry 
 | 
						||
                                        for a given remote connection entry."
 | 
						||
                ::=  {  plcChannelModulationEntry  17  }
 | 
						||
 | 
						||
 | 
						||
        plcChannelModulationInput OBJECT IDENTIFIER
 | 
						||
                ::=  { plcTopo  5 }
 | 
						||
        
 | 
						||
        plcModulationInputAddr OBJECT-TYPE     
 | 
						||
                SYNTAX                  MacAddress
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The MAC address of the MAC layer above 
 | 
						||
                                        the plc interface of the remote 
 | 
						||
                                        PLC equipment for which the modulation 
 | 
						||
                                        value changes are requested."
 | 
						||
                ::=  {  plcChannelModulationInput  1  }
 | 
						||
 | 
						||
        plcModulationInputChannel OBJECT-TYPE     
 | 
						||
                SYNTAX                  PlcChannelType
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The channel type of the remote PLC equipment
 | 
						||
                                        for which the modulation value changes 
 | 
						||
                                        are requested."
 | 
						||
                ::=  {  plcChannelModulationInput  2  }
 | 
						||
                                
 | 
						||
        plcModulationInputBand OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number of which the modulation value 
 | 
						||
                                        changes are requested."
 | 
						||
                ::=  {  plcChannelModulationInput  3  }
 | 
						||
                                                                
 | 
						||
        plcInputModulationGroup1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        first group of the considered band and 
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  4  }
 | 
						||
 | 
						||
        plcInputModulationGroup2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        second group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  5  }
 | 
						||
 | 
						||
        plcInputModulationGroup3 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        third group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  6  }
 | 
						||
 | 
						||
        plcInputModulationGroup4 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        fourth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  7  }
 | 
						||
 | 
						||
        plcInputModulationGroup5 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        fifth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  8  }
 | 
						||
 | 
						||
        plcInputModulationGroup6 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        sixth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  9  }
 | 
						||
 | 
						||
        plcInputModulationGroup7 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        seventh group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  10  }
 | 
						||
 | 
						||
        plcInputModulationGroup8 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        eighth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  11  }
 | 
						||
 | 
						||
        plcInputModulationGroup9 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        nineth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  12  }
 | 
						||
 | 
						||
        plcInputModulationGroup10 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        tenth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  13  }
 | 
						||
 | 
						||
        plcInputModulationGroup11 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        eleventh group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  14  }
 | 
						||
 | 
						||
        plcInputModulationGroup12 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        twelveth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  15  }
 | 
						||
 | 
						||
        plcInputModulationGroup13 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        thirteenth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  16  }
 | 
						||
 | 
						||
        plcInputModulationGroup14 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        fourteenth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  17  }
 | 
						||
 | 
						||
        plcInputModulationGroup15 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        fifteenth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  18  }
 | 
						||
 | 
						||
        plcInputModulationGroup16 OBJECT-TYPE     
 | 
						||
                SYNTAX                  ModulationValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The new requested modulation amplitude of the 
 | 
						||
                                        sixteenth group of the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelModulationInput  19  }
 | 
						||
 | 
						||
 | 
						||
        plcModulationInputProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request a modification of all the modulations
 | 
						||
                                        associated to a band and a channel of a remote
 | 
						||
                                        PLC equipment."
 | 
						||
                ::=  {  plcChannelModulationInput  20  }
 | 
						||
 | 
						||
         plcModulationInputResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  ResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested modulation value changes."
 | 
						||
                ::=  {  plcChannelModulationInput  21  }
 | 
						||
 | 
						||
        plcPortChannelTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcPortChannelEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains the list of plc channels"
 | 
						||
                ::=  { plcTopo  6 }
 | 
						||
 | 
						||
        plcPortChannelEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcPortChannelEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains plc channel information"
 | 
						||
                INDEX           {  plcBasePortIndex, plcPortChannelIndex   }
 | 
						||
                ::=  { plcPortChannelTable 1 }
 | 
						||
 | 
						||
        PlcPortChannelEntry  ::=  SEQUENCE {
 | 
						||
                plcPortChannelIndex        			Unsigned32,
 | 
						||
                plcPortChannelType         			PlcChannelType,
 | 
						||
                plcPortChannelGain         			Integer32,
 | 
						||
                plcPortChannelBandwidth   			ChannelBandwidthValue,
 | 
						||
                plcPortChannelMaxBandwidth 			ChannelBandwidthValue,
 | 
						||
                plcPortChannelSynchronizationBand 	BandValue
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        plcPortChannelIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  Unsigned32
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The channel number belongs to the remote connection 
 | 
						||
                                        with plc equipment associated with the 
 | 
						||
                                        plcBasePortIndex        value. 
 | 
						||
                                        Only three channels are expected.
 | 
						||
                                        Index 1 for RX channel
 | 
						||
                                        Index 2 for RXLast channel
 | 
						||
                                        index 3 for TX channel"
 | 
						||
                ::=  {  plcPortChannelEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        plcPortChannelType OBJECT-TYPE     
 | 
						||
                SYNTAX                  PlcChannelType
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The channel type."
 | 
						||
                ::=  {  plcPortChannelEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcPortChannelGain OBJECT-TYPE     
 | 
						||
                SYNTAX                  Integer32
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The gain associated with the channel."
 | 
						||
                ::=  {  plcPortChannelEntry  3  }
 | 
						||
                
 | 
						||
        plcPortChannelBandwidth OBJECT-TYPE     
 | 
						||
                SYNTAX                  ChannelBandwidthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The bandwidth of the channel in Kbit/s."
 | 
						||
                ::=  {  plcPortChannelEntry  4  }
 | 
						||
                                                        
 | 
						||
--PR01 BEGIN
 | 
						||
        plcPortChannelMaxBandwidth OBJECT-TYPE     
 | 
						||
                SYNTAX                  ChannelBandwidthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The maximum bandwidth of the channel in Kbit/s."
 | 
						||
                ::=  {  plcPortChannelEntry  5  }
 | 
						||
--PR01 END
 | 
						||
 | 
						||
		plcPortChannelSynchronizationBand OBJECT-TYPE       
 | 
						||
				SYNTAX					BandValue
 | 
						||
				MAX-ACCESS              read-only
 | 
						||
				STATUS					current
 | 
						||
				DESCRIPTION				"The synchronization band used for this channel."
 | 
						||
				::=  {  plcPortChannelEntry  6  }
 | 
						||
 | 
						||
        plcChannelPilotStringTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcChannelPilotStringEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains the string values representing
 | 
						||
                                        of pilot values of all active channels."
 | 
						||
                ::=  { plcTopo  7 }
 | 
						||
 | 
						||
 | 
						||
       plcChannelPilotStringEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcChannelPilotStringEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains a quick access for pilot values , 
 | 
						||
                                        of the remote connection referenced by 
 | 
						||
                                        plcBasePortIndex."
 | 
						||
                INDEX                   { plcBasePortIndex }
 | 
						||
                ::=  { plcChannelPilotStringTable 1 }
 | 
						||
 | 
						||
 | 
						||
        PlcChannelPilotStringEntry  ::=  SEQUENCE {
 | 
						||
                plcRxChannelPilots      OCTET STRING,
 | 
						||
                plcRxLastChannelPilots  OCTET STRING,
 | 
						||
                plcTxChannelPilots      OCTET STRING}
 | 
						||
 | 
						||
 | 
						||
        plcRxChannelPilots OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The carrier wave numbers which support  
 | 
						||
                                        the pilot waves for the Rx Channel.
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is a pair of octets representing the pilot 
 | 
						||
                                        values. There is one pair (pilot1 pilot2) for each
 | 
						||
                                        of the 7 bands."
 | 
						||
                ::=  {  plcChannelPilotStringEntry 1  }
 | 
						||
 | 
						||
 | 
						||
        plcRxLastChannelPilots OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The carrier wave numbers which support  
 | 
						||
                                        the pilot waves for the Rx Last Channel.
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is a pair of octets representing the pilot 
 | 
						||
                                        values. There is one pair (pilot1 pilot2) for each
 | 
						||
                                        of the 7 bands."
 | 
						||
                ::=  {  plcChannelPilotStringEntry 2  }
 | 
						||
                                
 | 
						||
                                
 | 
						||
        plcTxChannelPilots OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The carrier wave numbers which support  
 | 
						||
                                        the pilot waves for the Tx Channel.
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is a pair of octets representing the pilot 
 | 
						||
                                        values. There is one pair (pilot1 pilot2) for each
 | 
						||
                                        of the 7 bands."
 | 
						||
                ::=  {  plcChannelPilotStringEntry 3  }
 | 
						||
 | 
						||
 | 
						||
        plcChannelPilotsTable OBJECT-TYPE
 | 
						||
                SYNTAX                   SEQUENCE  OF  PlcChannelPilotsEntry
 | 
						||
                MAX-ACCESS               not-accessible
 | 
						||
                STATUS                   current
 | 
						||
                DESCRIPTION              "This tabel contains pilots configuration 
 | 
						||
                                         for each plc channel."
 | 
						||
                ::=  { plcTopo  8 }
 | 
						||
 | 
						||
 | 
						||
        plcChannelPilotsEntry OBJECT-TYPE
 | 
						||
                SYNTAX                   PlcChannelPilotsEntry
 | 
						||
                MAX-ACCESS               not-accessible
 | 
						||
                STATUS                   current
 | 
						||
                DESCRIPTION              "This row contains the pilots 1 and 2 configuration 
 | 
						||
                                         for a channel defined by the 
 | 
						||
                                         couple (plcBasePortIndex, plcPortChannelIndex)"
 | 
						||
                INDEX                    {   plcBasePortIndex, 
 | 
						||
                                             plcPortChannelIndex,
 | 
						||
                                             plcChannelPilotBandIndex  }
 | 
						||
                ::=  { plcChannelPilotsTable 1 }
 | 
						||
 | 
						||
        PlcChannelPilotsEntry  ::=  SEQUENCE {
 | 
						||
                plcChannelPilotBandIndex        BandValue,
 | 
						||
                plcChannelPilot1                PilotValue,
 | 
						||
                plcChannePilot2                 PilotValue
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        plcChannelPilotBandIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the pilots are defined."
 | 
						||
                ::=  {  plcChannelPilotsEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        plcChannelPilot1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The carrier wave number which supports  
 | 
						||
                                        the first pilot wave for the channel
 | 
						||
                                        associated with this entry."
 | 
						||
                ::=  {  plcChannelPilotsEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcChannePilot2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The carrier wave number which supports 
 | 
						||
                                        the second pilot wave for the channel
 | 
						||
                                        associated with this entry."
 | 
						||
                ::=  {  plcChannelPilotsEntry  3  }
 | 
						||
 | 
						||
 | 
						||
        plcChannelPilotsInput OBJECT IDENTIFIER
 | 
						||
                ::=  { plcTopo  9 }
 | 
						||
                                
 | 
						||
                plcPilotsInputAddr OBJECT-TYPE     
 | 
						||
                SYNTAX                  MacAddress
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The MAC address of the MAC layer above 
 | 
						||
                                        the plc interface of the remote 
 | 
						||
                                        PLC equipment for which the pilot 
 | 
						||
                                        value changes are requested."
 | 
						||
                ::=  {  plcChannelPilotsInput  1  }
 | 
						||
 | 
						||
        plcPilotsInputChannel OBJECT-TYPE     
 | 
						||
                SYNTAX                  PlcChannelType
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The channel type of the remote PLC equipment
 | 
						||
                                        for which the pilot value changes 
 | 
						||
                                        are requested."
 | 
						||
                ::=  {  plcChannelPilotsInput  2  }
 | 
						||
                                
 | 
						||
        plcPilotsInputBand OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number of which the pilots value 
 | 
						||
                                        changes are requested."
 | 
						||
                ::=  {  plcChannelPilotsInput  3  }
 | 
						||
 | 
						||
 | 
						||
        plcInputChannelPilot1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The carrier wave number which supports  
 | 
						||
                                        the first pilot wave for the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelPilotsInput  4  }
 | 
						||
 | 
						||
        plcInputChannelPilot2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The carrier wave number which supports  
 | 
						||
                                        the second pilot wave for the considered band and
 | 
						||
                                        channel input values."
 | 
						||
                ::=  {  plcChannelPilotsInput  5  }
 | 
						||
 | 
						||
        plcPilotsInputProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request a modification of the first and second pilot
 | 
						||
                                        associated to a band and a channel of a remote
 | 
						||
                                        PLC equipment."
 | 
						||
                ::=  {  plcChannelPilotsInput  6  }
 | 
						||
 | 
						||
         plcPilotsInputResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  ResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested pilot values changes."
 | 
						||
                ::=  {  plcChannelPilotsInput  7  }
 | 
						||
 | 
						||
        plcNodeNotches OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The values of the notches for all the node bands. 
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is an octet representing the 8 notches of 
 | 
						||
                                        each group. There is one value for each 7 * 16 bands."
 | 
						||
                ::=  {  plcNodeConfiguration 1  }
 | 
						||
 | 
						||
        plcNodeNotchesTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcNodeNotchesEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains Notches configuration 
 | 
						||
                                        for the SPC200 chip."
 | 
						||
                ::=  { plcNodeConfiguration  2 }
 | 
						||
 | 
						||
        plcNodeNotchesEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcNodeNotchesEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains Notches configuration for a group. 
 | 
						||
                                        The group is defined by the couple 
 | 
						||
                                        (plcNodeNotchesGroupIndex, plcNodeNotchesBandIndex)."
 | 
						||
                INDEX                   {  plcNodeNotchesBandIndex, plcNodeNotchesGroupIndex   }
 | 
						||
                ::=  { plcNodeNotchesTable 1 }
 | 
						||
 | 
						||
        PlcNodeNotchesEntry  ::=  SEQUENCE {
 | 
						||
                plcNodeNotchesBandIndex  BandValue,
 | 
						||
                plcNodeNotchesGroupIndex GroupValue,
 | 
						||
                plcNodeNotchesCarrier1   TruthValue,
 | 
						||
                plcNodeNotchesCarrier2   TruthValue,
 | 
						||
                plcNodeNotchesCarrier3   TruthValue,
 | 
						||
                plcNodeNotchesCarrier4   TruthValue,
 | 
						||
                plcNodeNotchesCarrier5   TruthValue,
 | 
						||
                plcNodeNotchesCarrier6   TruthValue,
 | 
						||
                plcNodeNotchesCarrier7   TruthValue,
 | 
						||
                plcNodeNotchesCarrier8   TruthValue
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesBandIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the notches are defined."
 | 
						||
                ::=  {  plcNodeNotchesEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesGroupIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  GroupValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The group number on which the notches are defined."
 | 
						||
                ::=  {  plcNodeNotchesEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the first carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  3  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the second carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  4  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier3 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the third carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  5  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier4 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the fourth carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  6  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier5 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the fifth carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  7  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier6 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the sixth carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  8  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier7 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the seventh carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  9  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesCarrier8 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Tell if the eighth carrier of the group entry 
 | 
						||
                                        of the band entry is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesEntry  10  }
 | 
						||
 | 
						||
        plcNodeNotchesInput OBJECT IDENTIFIER
 | 
						||
                ::=  { plcNodeConfiguration  3 }
 | 
						||
                                
 | 
						||
        plcNodeNotchesInputBand OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the notches value 
 | 
						||
                                        changes are requested."
 | 
						||
                ::=  {  plcNodeNotchesInput  1  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNotchesInputGroup OBJECT-TYPE     
 | 
						||
                SYNTAX                  GroupValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The group number on which the notches value 
 | 
						||
                                        changes are requested."
 | 
						||
                ::=  {  plcNodeNotchesInput  2  }
 | 
						||
 | 
						||
        plcNodeNotchesInputCarrier1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The first carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  3  }
 | 
						||
                                
 | 
						||
        plcNodeNotchesInputCarrier2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The second carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  4  }
 | 
						||
                                
 | 
						||
        plcNodeNotchesInputCarrier3 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The third carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  5  }
 | 
						||
                                
 | 
						||
        plcNodeNotchesInputCarrier4 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The fourth carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  6  }
 | 
						||
 | 
						||
        plcNodeNotchesInputCarrier5 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The eighth carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  7  }
 | 
						||
                                
 | 
						||
        plcNodeNotchesInputCarrier6 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The eighth carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  8  }
 | 
						||
                                
 | 
						||
        plcNodeNotchesInputCarrier7 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The seventh carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  9  }
 | 
						||
                                
 | 
						||
        plcNodeNotchesInputCarrier8 OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The eighth carrier of the considered group and 
 | 
						||
                                        band is a notch carrier. 
 | 
						||
                                        The true value means the current carrier is a notch."
 | 
						||
                ::=  {  plcNodeNotchesInput  10  }
 | 
						||
                              
 | 
						||
        plcNodeNotchesInputProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request a modification of the carrier notches
 | 
						||
                                        associated to the considered group and 
 | 
						||
                                        band."
 | 
						||
                ::=  {  plcNodeNotchesInput  11  }
 | 
						||
 | 
						||
         plcNodeNotchesInputResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  ResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested node carrier notches value changes."
 | 
						||
                ::=  {  plcNodeNotchesInput  12  }
 | 
						||
 | 
						||
 | 
						||
        plcNodePilots OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The values of the pilot for all the node bands. 
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is a pair of octets representing the pilot 
 | 
						||
                                        values. There is one pair (pilot1 pilot2) for each
 | 
						||
                                        of the 7 bands."
 | 
						||
                ::=  {  plcNodeConfiguration 4  }
 | 
						||
 | 
						||
        plcNodePilotsTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcNodePilotsEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains pilot values 
 | 
						||
                                        used by default on all channels."
 | 
						||
                ::=  { plcNodeConfiguration  5 }
 | 
						||
 | 
						||
        plcNodePilotsEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcNodePilotsEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains pilot values 
 | 
						||
                                        used by default on a band. 
 | 
						||
                                        The band is defined by the index 
 | 
						||
                                        plcNodePilotsBandIndex."
 | 
						||
                INDEX                   {  plcNodePilotsBandIndex  }
 | 
						||
                ::=  { plcNodePilotsTable 1 }
 | 
						||
 | 
						||
        PlcNodePilotsEntry  ::=  SEQUENCE {
 | 
						||
                plcNodePilotsBandIndex  BandValue,
 | 
						||
                plcNodePilot1           PilotValue,
 | 
						||
                plcNodePilot2           PilotValue
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        plcNodePilotsBandIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the pilot values are defined."
 | 
						||
                ::=  {  plcNodePilotsEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        plcNodePilot1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The default carrier wave number 
 | 
						||
                                        which supports the first pilot wave."
 | 
						||
                ::=  {  plcNodePilotsEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcNodePilot2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The default carrier wave number 
 | 
						||
                                        which supports the second pilot wave."
 | 
						||
                ::=  {  plcNodePilotsEntry  3  }
 | 
						||
 | 
						||
 | 
						||
        plcNodePilotsInput OBJECT IDENTIFIER
 | 
						||
                ::=  { plcNodeConfiguration  6 }
 | 
						||
                                
 | 
						||
        plcNodePilotsInputBand OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the pilot values 
 | 
						||
                                        changes are requested."
 | 
						||
                ::=  {  plcNodePilotsInput  1  }
 | 
						||
 | 
						||
 | 
						||
        plcInputNodePilot1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The default carrier wave number 
 | 
						||
                                        which supports the first pilot wave of 
 | 
						||
                                        the considered band."
 | 
						||
                ::=  {  plcNodePilotsInput  2  }
 | 
						||
                                
 | 
						||
        plcInputNodePilot2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  PilotValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The default carrier wave number 
 | 
						||
                                        which supports the second pilot wave of 
 | 
						||
                                        the considered band."
 | 
						||
                ::=  {  plcNodePilotsInput  3  }
 | 
						||
 | 
						||
                              
 | 
						||
        plcNodePilotsInputProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request a modification of the pilot values
 | 
						||
                                        associated to the considered band."
 | 
						||
                ::=  {  plcNodePilotsInput  4  }
 | 
						||
 | 
						||
         plcNodePilotsInputResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  ResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested node pilot values changes."
 | 
						||
                ::=  {  plcNodePilotsInput  5  }
 | 
						||
                
 | 
						||
       plcNodeAdaptsStringTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE OF PlcNodeAdaptsStringEntry               
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains string values for a 
 | 
						||
                                        quick access to the adapt configurations 
 | 
						||
                                        of all the carriers."
 | 
						||
                ::=  { plcNodeConfiguration  7 }
 | 
						||
 | 
						||
 | 
						||
       plcNodeAdaptsStringEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcNodeAdaptsStringEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains string values for a quick access to 
 | 
						||
                                        the adapt configuration
 | 
						||
                                        of each carrier of a band."
 | 
						||
                INDEX                   { plcBasePortIndex , plcNodeAdaptsStringBandIndex  }
 | 
						||
                ::=  { plcNodeAdaptsStringTable 1 }
 | 
						||
 | 
						||
        PlcNodeAdaptsStringEntry  ::=  SEQUENCE {
 | 
						||
                plcNodeAdaptsStringBandIndex BandValue,
 | 
						||
                plcNodeAdaptsStringBand      OCTET STRING }
 | 
						||
 | 
						||
        plcNodeAdaptsStringBandIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the adapt values are defined."
 | 
						||
                ::=  {  plcNodeAdaptsStringEntry  1  }
 | 
						||
 | 
						||
        plcNodeAdaptsStringBand OBJECT-TYPE     
 | 
						||
                SYNTAX                  OCTET STRING
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt values of the 128 carriers of a band.
 | 
						||
                                        The expected format is VALUE VALUE VALUE ... VALUE.
 | 
						||
                                        Each value is two octets representing one adapt carrier 
 | 
						||
                                        level.
 | 
						||
                                        There are ( 16 groups * 8 carriers)  = 128 values."
 | 
						||
                ::=  {  plcNodeAdaptsStringEntry 2  }
 | 
						||
       
 | 
						||
       plcNodeAdaptsTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE OF PlcNodeAdaptsEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains adapt level configuration 
 | 
						||
                                        for each carrier of the node."
 | 
						||
                ::=  { plcNodeConfiguration  8 }
 | 
						||
 | 
						||
        plcNodeAdaptsEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcNodeAdaptsEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains adapt level values 
 | 
						||
                                        for a group of carriers. 
 | 
						||
                                        The group is defined by the couple
 | 
						||
                                        (plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex)."
 | 
						||
                INDEX                   {  plcNodeAdaptsBandIndex,plcNodeAdaptsGroupIndex  }
 | 
						||
                ::=  { plcNodeAdaptsTable 1 }
 | 
						||
 | 
						||
        PlcNodeAdaptsEntry  ::=  SEQUENCE {
 | 
						||
                plcNodeAdaptsBandIndex  BandValue,
 | 
						||
                plcNodeAdaptsGroupIndex GroupValue,
 | 
						||
                plcNodeAdaptsCarrier1   AdaptValue,
 | 
						||
                plcNodeAdaptsCarrier2   AdaptValue,
 | 
						||
                plcNodeAdaptsCarrier3   AdaptValue,
 | 
						||
                plcNodeAdaptsCarrier4   AdaptValue,
 | 
						||
                plcNodeAdaptsCarrier5   AdaptValue,
 | 
						||
                plcNodeAdaptsCarrier6   AdaptValue,
 | 
						||
                plcNodeAdaptsCarrier7   AdaptValue,
 | 
						||
                plcNodeAdaptsCarrier8   AdaptValue
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        plcNodeAdaptsBandIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the adapt values are defined."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  1  }
 | 
						||
 | 
						||
        plcNodeAdaptsGroupIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  GroupValue
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The group number on which the adapt values are defined."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  2  }
 | 
						||
 | 
						||
        plcNodeAdaptsCarrier1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the first carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  3  }
 | 
						||
                
 | 
						||
        plcNodeAdaptsCarrier2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the second carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  4  }
 | 
						||
 | 
						||
        plcNodeAdaptsCarrier3 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the third carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  5  }
 | 
						||
 | 
						||
        plcNodeAdaptsCarrier4 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the fourth carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  6 }         
 | 
						||
                
 | 
						||
        plcNodeAdaptsCarrier5 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the fifth carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  7 }         
 | 
						||
                
 | 
						||
        plcNodeAdaptsCarrier6 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the sixth carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  8 }         
 | 
						||
 | 
						||
        plcNodeAdaptsCarrier7 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the seventh carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  9 }                         
 | 
						||
                
 | 
						||
        plcNodeAdaptsCarrier8 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the eighth carrier of the group."
 | 
						||
                ::=  {  plcNodeAdaptsEntry  10 }  
 | 
						||
                               
 | 
						||
        plcNodeAdaptsInput OBJECT IDENTIFIER
 | 
						||
                ::=  { plcNodeConfiguration  9 }
 | 
						||
                                
 | 
						||
        plcNodeAdaptsInputBand OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The band number on which the adapt level value 
 | 
						||
                                        changes are requested."
 | 
						||
                ::=  {  plcNodeAdaptsInput  1  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeAdaptsInputGroup OBJECT-TYPE     
 | 
						||
                SYNTAX                  GroupValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The group number on which the adapt level value 
 | 
						||
                                         changes are requested."
 | 
						||
                ::=  {  plcNodeAdaptsInput  2  }
 | 
						||
 | 
						||
        plcNodeAdaptsInputCarrier1 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the first carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  3  }
 | 
						||
                                
 | 
						||
        plcNodeAdaptsInputCarrier2 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the second carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  4  }
 | 
						||
                                
 | 
						||
        plcNodeAdaptsInputCarrier3 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the third carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  5  }
 | 
						||
                                
 | 
						||
        plcNodeAdaptsInputCarrier4 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the fourth carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  6  }
 | 
						||
 | 
						||
        plcNodeAdaptsInputCarrier5 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the fifth carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  7  }
 | 
						||
                                
 | 
						||
        plcNodeAdaptsInputCarrier6 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the sixth carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  8  }
 | 
						||
                                
 | 
						||
        plcNodeAdaptsInputCarrier7 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the seventh carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  9  }
 | 
						||
                                
 | 
						||
        plcNodeAdaptsInputCarrier8 OBJECT-TYPE     
 | 
						||
                SYNTAX                  AdaptValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The adapt level of the eighth carrier of the 
 | 
						||
                                        considered group of the chosen band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  10  }
 | 
						||
                              
 | 
						||
        plcNodeAdaptsInputProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request a modification of the carrier 
 | 
						||
                                        adapt level associated to the considered group and 
 | 
						||
                                        band."
 | 
						||
                ::=  {  plcNodeAdaptsInput  11  }
 | 
						||
 | 
						||
         plcNodeAdaptsInputResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  ResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested node adapt level 
 | 
						||
                                        value changes."
 | 
						||
                ::=  {  plcNodeAdaptsInput  12  }
 | 
						||
       
 | 
						||
        plcNodeNetConfigTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  PlcNodeNetConfigEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains ip and mac 
 | 
						||
                                        addresses of the node."
 | 
						||
                ::=  { plcNodeConfiguration  10 }
 | 
						||
 | 
						||
        plcNodeNetConfigEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  PlcNodeNetConfigEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains ip and mac address
 | 
						||
                                        used by an interface."
 | 
						||
                INDEX                   {  ifIndex  }
 | 
						||
                ::=  { plcNodeNetConfigTable 1 }
 | 
						||
 | 
						||
        PlcNodeNetConfigEntry  ::=  SEQUENCE {
 | 
						||
                plcNodeIpAddr   IpAddress,
 | 
						||
                plcNodeNetMask  IpAddress,
 | 
						||
                plcNodeMacAddr  MacAddress,
 | 
						||
                plcNodeGateway  IpAddress
 | 
						||
                }
 | 
						||
 | 
						||
 | 
						||
        plcNodeIpAddr OBJECT-TYPE     
 | 
						||
                SYNTAX                  IpAddress
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The IP address of the IP layer above the interface."
 | 
						||
                ::=  {  plcNodeNetConfigEntry  1  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeNetMask OBJECT-TYPE     
 | 
						||
                SYNTAX                  IpAddress
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The IP Subnet mask of the IP layer above the interface."
 | 
						||
                ::=  {  plcNodeNetConfigEntry  2  }
 | 
						||
 | 
						||
 | 
						||
        plcNodeMacAddr OBJECT-TYPE     
 | 
						||
                SYNTAX                  MacAddress
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The MAC address of the MAC layer above the interface."
 | 
						||
                ::=  {  plcNodeNetConfigEntry  3  }
 | 
						||
                
 | 
						||
        plcNodeGateway OBJECT-TYPE     
 | 
						||
                SYNTAX                  IpAddress
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The Gateway address of the IP layer above the interface."
 | 
						||
                ::=  {  plcNodeNetConfigEntry  4  }
 | 
						||
                
 | 
						||
        plcNodeActions OBJECT IDENTIFIER
 | 
						||
                ::=  { plcNodeConfiguration  11 }
 | 
						||
                
 | 
						||
        plcNodeActionsCommit OBJECT IDENTIFIER
 | 
						||
                ::=  { plcNodeActions  1 }
 | 
						||
                
 | 
						||
        plcNodeActionsCommitProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request the commit of the configuration 
 | 
						||
                                        changes into the flash memory"
 | 
						||
                ::=  {  plcNodeActionsCommit  1  }
 | 
						||
 | 
						||
         plcNodeActionsCommitResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  ResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested flash commit operation."
 | 
						||
                ::=  {  plcNodeActionsCommit  2  }
 | 
						||
            
 | 
						||
         plcNodeActionsReset OBJECT IDENTIFIER
 | 
						||
                ::=  { plcNodeActions  2 }
 | 
						||
                
 | 
						||
         plcNodeActionsResetProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request the reset of the node.
 | 
						||
                                        This operation will terminate the communication 
 | 
						||
                                        between the manager and the node"
 | 
						||
                ::=  {  plcNodeActionsReset  1  }
 | 
						||
                
 | 
						||
         plcNodeActionsCarrier OBJECT IDENTIFIER
 | 
						||
                ::=  { plcNodeActions  3 }
 | 
						||
                
 | 
						||
         plcNodeActionsCarrierFlatProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request the equipment to flat the signal"
 | 
						||
                ::=  {  plcNodeActionsCarrier  1  }
 | 
						||
                
 | 
						||
                
 | 
						||
plcBssId OBJECT IDENTIFIER
 | 
						||
                  ::=  {  plcObjects  6  }
 | 
						||
                
 | 
						||
plcMasterBssId  OBJECT-TYPE
 | 
						||
	  SYNTAX                  INTEGER(0..99)
 | 
						||
          MAX-ACCESS              read-write
 | 
						||
          STATUS                  current
 | 
						||
          DESCRIPTION             "The value of the master Bss Id"
 | 
						||
                  ::=  {  plcBssId  1  }   
 | 
						||
                  
 | 
						||
plcSlaveBssId  OBJECT-TYPE
 | 
						||
	  SYNTAX                  INTEGER(0..99)
 | 
						||
          MAX-ACCESS              read-write
 | 
						||
          STATUS                  current
 | 
						||
          DESCRIPTION             "The value of the slave Bss Id"
 | 
						||
                  ::=  {  plcBssId  2  }                     
 | 
						||
                  
 | 
						||
plcSpy OBJECT IDENTIFIER
 | 
						||
                  ::=  {  plcObjects  7  }
 | 
						||
 | 
						||
plcSpyIsDynamic OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to set the spy dynamic mode"
 | 
						||
                ::=  {  plcSpy  1  }
 | 
						||
 | 
						||
plcStaticSpySynchBandNb OBJECT-TYPE     
 | 
						||
                SYNTAX                  BandValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The synchronization band number used for static spy mode"
 | 
						||
                ::=  {  plcSpy  2  }
 | 
						||
                           
 | 
						||
                                                                                                                                        
 | 
						||
-- software upload
 | 
						||
        softwareMgnt  OBJECT IDENTIFIER
 | 
						||
                ::=  {  plc  3  }
 | 
						||
                
 | 
						||
        -- current version
 | 
						||
        currentSoftwareVersion OBJECT-TYPE     
 | 
						||
                SYNTAX                  DisplayString (SIZE (0..255))
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The name of the current software release."
 | 
						||
                ::=  {  softwareMgnt  1 }
 | 
						||
                
 | 
						||
        currentSoftwareBoardVersion OBJECT-TYPE     
 | 
						||
                SYNTAX                  DisplayString (SIZE (0..255))
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The name of the current software board release."
 | 
						||
                ::=  {  softwareMgnt  2 }
 | 
						||
             
 | 
						||
        currentSoftwareAFEVersion OBJECT-TYPE     
 | 
						||
                SYNTAX                  DisplayString (SIZE (0..255))
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The name of the current software Analog Front End  release."
 | 
						||
                ::=  {  softwareMgnt  3 }
 | 
						||
                
 | 
						||
-- table of software
 | 
						||
        softwareTable OBJECT-TYPE
 | 
						||
                SYNTAX                  SEQUENCE  OF  SoftwareEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This table contains the current and reserve 
 | 
						||
                                        softwares of the node."
 | 
						||
                ::=  { softwareMgnt  4 }
 | 
						||
 | 
						||
        softwareEntry OBJECT-TYPE
 | 
						||
                SYNTAX                  SoftwareEntry
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "This row contains software information."
 | 
						||
                INDEX                   {  softwareIndex  }
 | 
						||
                ::=  { softwareTable 1 }
 | 
						||
 | 
						||
        SoftwareEntry  ::=  SEQUENCE {
 | 
						||
                softwareIndex           SoftwareIndex,
 | 
						||
                softwareVersion         DisplayString
 | 
						||
                }
 | 
						||
 | 
						||
        softwareIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  SoftwareIndex
 | 
						||
                MAX-ACCESS              not-accessible
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The index number of the software."
 | 
						||
                ::=  {  softwareEntry  1  }
 | 
						||
                
 | 
						||
        softwareVersion OBJECT-TYPE     
 | 
						||
                SYNTAX                  DisplayString (SIZE (0..255))
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The name of the software release."
 | 
						||
                ::=  {  softwareEntry  2  }
 | 
						||
                
 | 
						||
        -- upload software action
 | 
						||
        softwareUpload OBJECT IDENTIFIER
 | 
						||
                ::=  {  softwareMgnt  5 }
 | 
						||
                
 | 
						||
        softwareUploadTFTPServerIP OBJECT-TYPE     
 | 
						||
                SYNTAX                  IpAddress
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The IP address of the TFTP serveur"
 | 
						||
                ::=  {  softwareUpload  1  }
 | 
						||
 | 
						||
 | 
						||
        softwareUploadLogin OBJECT-TYPE     
 | 
						||
                SYNTAX                  DisplayString (SIZE (0..16))
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The user login on the TFTP server"
 | 
						||
                ::=  {  softwareUpload  2  }
 | 
						||
               
 | 
						||
        softwareUploadPassword OBJECT-TYPE     
 | 
						||
                SYNTAX                  DisplayString (SIZE (0..16))
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The user password on the TFTP server. 
 | 
						||
                                        Warning: This field is displayed using 6 * characters"
 | 
						||
                ::=  {  softwareUpload  3  }
 | 
						||
         
 | 
						||
        softwareUploadFileName OBJECT-TYPE     
 | 
						||
                SYNTAX                  DisplayString (SIZE (0..255))
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The software file name to upload"
 | 
						||
                ::=  {  softwareUpload  4  }
 | 
						||
 | 
						||
         softwareUploadProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request the uploading to start"
 | 
						||
                ::=  {  softwareUpload  5  }
 | 
						||
                
 | 
						||
         softwareUploadResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  SoftwareActionResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested uploading"
 | 
						||
                ::=  {  softwareUpload  6  }
 | 
						||
 | 
						||
         softwareUploadTFTPServerPort OBJECT-TYPE     -- PR01
 | 
						||
                SYNTAX                  Integer32 ( 0..65535 )
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The service port of the TFTP server"
 | 
						||
                ::=  {  softwareUpload  7  }
 | 
						||
 | 
						||
         
 | 
						||
-- software action
 | 
						||
        softwareAction  OBJECT IDENTIFIER
 | 
						||
                ::=  {  softwareMgnt  6 }
 | 
						||
                
 | 
						||
        softwareActionIndex OBJECT-TYPE     
 | 
						||
                SYNTAX                  SoftwareIndex
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The index of the reserve software"
 | 
						||
                ::=  {  softwareAction  1  }
 | 
						||
                
 | 
						||
         softwareActionType OBJECT-TYPE     
 | 
						||
                SYNTAX                  SoftwareActionType
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Type of the software action software:
 | 
						||
                                        switch, remove "
 | 
						||
                ::=  {  softwareAction  2  }
 | 
						||
 | 
						||
         softwareActionProceed OBJECT-TYPE     
 | 
						||
                SYNTAX                  TruthValue
 | 
						||
                MAX-ACCESS              read-write
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "True to request the switch between the current 
 | 
						||
                                        and the reserver software to start"
 | 
						||
                ::=  {  softwareAction  3  }
 | 
						||
           
 | 
						||
         softwareActionResult OBJECT-TYPE     
 | 
						||
                SYNTAX                  SoftwareActionResultValue
 | 
						||
                MAX-ACCESS              read-only
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "Result value of the requested action"
 | 
						||
                ::=  {  softwareAction  4  }
 | 
						||
 | 
						||
         
 | 
						||
-- compliance
 | 
						||
        plcConformance OBJECT IDENTIFIER
 | 
						||
                ::=  {  plc  4  }
 | 
						||
                
 | 
						||
        plcCompliances OBJECT IDENTIFIER
 | 
						||
                ::=  {  plcConformance  1  }
 | 
						||
 | 
						||
        plcGroups OBJECT IDENTIFIER
 | 
						||
                ::=  {  plcConformance  2  }
 | 
						||
                
 | 
						||
        plcCompliance MODULE-COMPLIANCE
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The compliance statement for SPC200 chip."
 | 
						||
 | 
						||
                MODULE  
 | 
						||
                MANDATORY-GROUPS        { nodeGroup, topologyGroup }
 | 
						||
                GROUP                   statisticGroup
 | 
						||
                DESCRIPTION             "This group is mandatory for 
 | 
						||
                                        channel performances analysis"
 | 
						||
                ::=  {  plcCompliances  1  }
 | 
						||
 | 
						||
        nodeGroup OBJECT-GROUP
 | 
						||
                OBJECTS                 { plcNodeNotches, plcMode,
 | 
						||
                                          plcNodeNotchesCarrier1, plcNodeNotchesCarrier2, 
 | 
						||
                                          plcNodeNotchesCarrier3, plcNodeNotchesCarrier4,
 | 
						||
                                          plcNodeNotchesCarrier5, plcNodeNotchesCarrier6, 
 | 
						||
                                          plcNodeNotchesCarrier7, plcNodeNotchesCarrier8, 
 | 
						||
                                          plcNodePilots, plcNodePilot1, plcNodePilot2,
 | 
						||
                                          plcNodeAdaptsStringBand, plcNodeAdaptsCarrier1,
 | 
						||
                                          plcNodeAdaptsCarrier2, plcNodeAdaptsCarrier3,
 | 
						||
                                          plcNodeAdaptsCarrier4, plcNodeAdaptsCarrier5,
 | 
						||
                                          plcNodeAdaptsCarrier6, plcNodeAdaptsCarrier7,
 | 
						||
                                          plcNodeAdaptsCarrier8,
 | 
						||
                                          plcNodeIpAddr, plcNodeNetMask, plcNodeMacAddr,
 | 
						||
                                          plcNodeGateway, plcMasterBssId, plcSlaveBssId,
 | 
						||
                                          plcSpyIsDynamic, plcStaticSpySynchBandNb }
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "A collection of objects providing 
 | 
						||
                                        node configuration information."
 | 
						||
                ::=  {  plcGroups  1  }
 | 
						||
 | 
						||
                inputNodeGroup OBJECT-GROUP
 | 
						||
               OBJECTS                 { plcNodeNotchesInputBand, plcNodeNotchesInputGroup,
 | 
						||
                                         plcNodeNotchesInputCarrier1, plcNodeNotchesInputCarrier2, 
 | 
						||
                                         plcNodeNotchesInputCarrier3, plcNodeNotchesInputCarrier4,
 | 
						||
                                         plcNodeNotchesInputCarrier5, plcNodeNotchesInputCarrier6, 
 | 
						||
                                         plcNodeNotchesInputCarrier7, plcNodeNotchesInputCarrier8, 
 | 
						||
                                         plcNodeNotchesInputProceed,  plcNodeNotchesInputResult,
 | 
						||
                                         plcNodePilotsInputBand,
 | 
						||
                                         plcInputNodePilot1, plcInputNodePilot2,
 | 
						||
                                         plcNodePilotsInputProceed,plcNodePilotsInputResult,                                        
 | 
						||
                                         plcNodeAdaptsInputBand, plcNodeAdaptsInputGroup,  
 | 
						||
                                         plcNodeAdaptsInputCarrier1, plcNodeAdaptsInputCarrier2,
 | 
						||
                                         plcNodeAdaptsInputCarrier3, plcNodeAdaptsInputCarrier4,
 | 
						||
                                         plcNodeAdaptsInputCarrier5, plcNodeAdaptsInputCarrier6,
 | 
						||
                                         plcNodeAdaptsInputCarrier7, plcNodeAdaptsInputCarrier8,
 | 
						||
                                         plcNodeAdaptsInputProceed,  plcNodeAdaptsInputResult,
 | 
						||
                                         plcNodeActionsCommitProceed, plcNodeActionsCommitResult,
 | 
						||
                                         plcNodeActionsResetProceed, plcNodeActionsCarrierFlatProceed}
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "A collection of objects used to request  
 | 
						||
                                        node configuration information changes."
 | 
						||
                ::=  {  plcGroups  2  }
 | 
						||
 | 
						||
        topologyGroup OBJECT-GROUP
 | 
						||
                OBJECTS         { plcBasePortAddress, plcBasePortChannelEstimation,
 | 
						||
                				  plcBasePortAttenuation ,
 | 
						||
                                        plcChannePilot2, plcChannelPilot1,
 | 
						||
                                        plcRxChannelPilots,
 | 
						||
                                        plcRxLastChannelPilots,
 | 
						||
                                        plcTxChannelPilots, 
 | 
						||
                                        plcRxChannelModulation,
 | 
						||
                                        plcRxLastChannelModulation,
 | 
						||
                                        plcTxChannelModulation, 
 | 
						||
                                        plcModGroup1, plcModGroup10, plcModGroup11, 
 | 
						||
                                        plcModGroup12, plcModGroup13, plcModGroup14, 
 | 
						||
                                        plcModGroup15, plcModGroup16, plcModGroup2, 
 | 
						||
                                        plcModGroup3, plcModGroup4, plcModGroup5, 
 | 
						||
                                        plcModGroup6, plcModGroup7, plcModGroup8, 
 | 
						||
                                        plcModGroup9, 
 | 
						||
                                        plcPortChannelGain, 
 | 
						||
                                        plcPortChannelBandwidth,
 | 
						||
                                        plcPortChannelMaxBandwidth, 
 | 
						||
                                        plcPortChannelSynchronizationBand,
 | 
						||
                                        plcPortChannelType, plcTopoChanges }
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "A collection of objects providing 
 | 
						||
                                        topology configuration."
 | 
						||
                ::=  {  plcGroups  3  }
 | 
						||
 | 
						||
        inputTopologyGroup OBJECT-GROUP
 | 
						||
                OBJECTS         {       plcModulationInputAddr, plcModulationInputChannel, plcModulationInputBand,
 | 
						||
                                        plcInputModulationGroup1, plcInputModulationGroup2,
 | 
						||
                                        plcInputModulationGroup3, plcInputModulationGroup4, 
 | 
						||
                                        plcInputModulationGroup5, plcInputModulationGroup6, 
 | 
						||
                                        plcInputModulationGroup7, plcInputModulationGroup8, 
 | 
						||
                                        plcInputModulationGroup9, plcInputModulationGroup10, 
 | 
						||
                                        plcInputModulationGroup11, plcInputModulationGroup12,
 | 
						||
                                        plcInputModulationGroup13, plcInputModulationGroup14,
 | 
						||
                                        plcInputModulationGroup15, plcInputModulationGroup16,
 | 
						||
                                        plcModulationInputProceed, plcModulationInputResult,
 | 
						||
                                        plcPilotsInputAddr, plcPilotsInputChannel, plcPilotsInputBand,
 | 
						||
                                        plcInputChannelPilot1, plcInputChannelPilot2,
 | 
						||
                                        plcPilotsInputProceed, plcPilotsInputResult }
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "A collection of objects used to request  
 | 
						||
                                        topology configuration changes."
 | 
						||
                ::=  {  plcGroups  4  }
 | 
						||
 | 
						||
        statisticGroup OBJECT-GROUP
 | 
						||
                OBJECTS         {    --PR01 BEGIN
 | 
						||
                                     --   ipBridgedPackets, ipInBridgedPkts, 
 | 
						||
                                     --   ipInErrorPackets, ipInErrorPkts, ipInPackets, 
 | 
						||
                                     --   ipInPkts, ipOutErrorPackets, ipOutErrorPkts, 
 | 
						||
                                     --   ipOutPackets, ipOutPkts, macInErrorPkts, 
 | 
						||
                                     --   macInPkts, macOutErrorPkts, macOutPackets, 
 | 
						||
                                     --   plcpInErrorPkts, plcpInPkts, plcpOutErrorPkts,
 | 
						||
                                     --   plcpOutPkts, 
 | 
						||
                                     --PR01 END
 | 
						||
                                        portStats2AvgBandAtt, portStats2AvgBandSNR, --PR01
 | 
						||
                                     --   portStats2Ber,
 | 
						||
                                        portStats2Noise, portStats2Signal,       
 | 
						||
                                     --   portStatsBer,
 | 
						||
                                        portStatsNoise, portStatsSignal,
 | 
						||
                                        portStats3AvgAtt, portStats3AvgSNR  ,
 | 
						||
                                        bootstatsBoot, bootstatsManualReset, bootstatsFailureReset
 | 
						||
                                         } --PR01
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "A collection of objects providing 
 | 
						||
                                        statistic data on node and plc link performances."
 | 
						||
                ::=  {  plcGroups  5  }
 | 
						||
 | 
						||
        softwareGroup OBJECT-GROUP
 | 
						||
                OBJECTS         {       currentSoftwareVersion, currentSoftwareBoardVersion, 
 | 
						||
                                        currentSoftwareAFEVersion, softwareVersion,
 | 
						||
                                        softwareUploadTFTPServerIP, softwareUploadLogin,
 | 
						||
                                        softwareUploadPassword, softwareUploadFileName,
 | 
						||
                                        softwareUploadProceed, softwareUploadResult,
 | 
						||
                                        softwareUploadTFTPServerPort, --PR01
 | 
						||
                                        softwareActionIndex, softwareActionType,
 | 
						||
                                        softwareActionProceed, softwareActionResult }
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "A collection of objects providing 
 | 
						||
                                        software management"
 | 
						||
                ::=  {  plcGroups  6  }
 | 
						||
 | 
						||
--PR01 BEGIN
 | 
						||
        analyserGroup OBJECT-GROUP
 | 
						||
                OBJECTS         {       plcSNAnalyserAGC, plcSNAnalyserEnable,
 | 
						||
                                        plcSNAnalyserMinSignal, plcSNAnalyserMaxSignal,
 | 
						||
                                        plcSNAnalyserAvgSignal, plcSNAnalyserLastSignal,
 | 
						||
                                        plcSNAnalyserFFTDiv,
 | 
						||
                                        plcAGCAnalyserEnable,
 | 
						||
                                        plcAGCAnalyserSamplesPart1, plcAGCAnalyserSamplesPart2 }
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "A collection of objects providing 
 | 
						||
                                        spectrum analyser data"
 | 
						||
                ::=  {  plcGroups  7  }
 | 
						||
--PR01 END
 | 
						||
 | 
						||
        agentCapabilities AGENT-CAPABILITIES
 | 
						||
                PRODUCT-RELEASE         "Product-Release"
 | 
						||
                STATUS                  current
 | 
						||
                DESCRIPTION             "The SPC200 chip SNMP agent capabilities"
 | 
						||
 | 
						||
                SUPPORTS                SPC200
 | 
						||
                        INCLUDES        { nodeGroup, inputNodeGroup, 
 | 
						||
                                          topologyGroup, inputTopologyGroup, 
 | 
						||
                                          statisticGroup, softwareGroup,
 | 
						||
                                          analyserGroup } --PR01
 | 
						||
                                                                  
 | 
						||
--OK                SUPPORTS               IF-MIB
 | 
						||
--OK                        INCLUDES        { ifGeneralInformationGroup, ifHCPacketGroup }                   
 | 
						||
--OK                        VARIATION       ifAdminStatus
 | 
						||
--OK                                ACCESS                          read-only
 | 
						||
--OK                                DESCRIPTION                     "Forbid the update of the administrative status"                    
 | 
						||
--OK                       VARIATION       ifLinkUpDownTrapEnable
 | 
						||
--OK                                ACCESS                          not-implemented
 | 
						||
--OK                                DESCRIPTION                     "No trap supported"
 | 
						||
--KO                       VARIATION       ifAlias
 | 
						||
--KO                                ACCESS                          not-implemented
 | 
						||
--KO                                DESCRIPTION                     "The non volatile alias name 
 | 
						||
--KO                                                                cannot be saved on the SPC200 chip"
 | 
						||
--KO                        VARIATION       ifMtu
 | 
						||
--KO                                ACCESS                          not-implemented
 | 
						||
--KO                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                                
 | 
						||
                SUPPORTS               MAU-MIB
 | 
						||
                        INCLUDES        { mauIfGrpBasic }
 | 
						||
                        VARIATION       ifMauIndex
 | 
						||
                                DESCRIPTION                     "Only one MAU. So the value is always 1"
 | 
						||
                        VARIATION       ifMauMediaAvailable
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ifMauMediaAvailableStateExits
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ifMauJabberState
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ifMauJabberingStateEnters
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                                
 | 
						||
                SUPPORTS               IP-MIB
 | 
						||
                        INCLUDES        { ipGroup }
 | 
						||
                        VARIATION       ipForwarding
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipDefaultTTL
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipInHdrErrors
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipInAddrErrors
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipForwDatagrams
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipInUnknownProtos
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipInDiscards
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipInDelivers
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipOutDiscards
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipOutNoRoutes
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipReasmTimeout
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipReasmReqds
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipReasmOKs
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipReasmFails
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipFragOKs
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipFragFails
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipFragCreates
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipAdEntBcastAddr
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipAdEntReasmMaxSize
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                        VARIATION       ipRoutingDiscards
 | 
						||
                                ACCESS                          not-implemented
 | 
						||
                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                                
 | 
						||
                SUPPORTS                        SNMPv2-MIB
 | 
						||
                        INCLUDES        { systemGroup }
 | 
						||
                        
 | 
						||
--OK                SUPPORTS                        BRIDGE-MIB
 | 
						||
--OK                        INCLUDES        { dot1dBase }
 | 
						||
--KO                        VARIATION       dot1dBasePortDelayExceededDiscards
 | 
						||
--KO                                ACCESS                          not-implemented
 | 
						||
--KO                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
--KO                        VARIATION       dot1dBasePortMtuExceededDiscards
 | 
						||
--KO                                ACCESS                          not-implemented
 | 
						||
--KO                                DESCRIPTION                     "Information not available on SPC200 chip"
 | 
						||
                                
 | 
						||
                ::=  {  plcConformance  3  }
 | 
						||
                        
 | 
						||
                
 | 
						||
-- ifTableExt data
 | 
						||
 | 
						||
--ifTableExt OBJECT-TYPE                                  
 | 
						||
--       SYNTAX SEQUENCE OF IfEntryExt
 | 
						||
--	MAX-ACCESS not-accessible
 | 
						||
--	STATUS current
 | 
						||
--	DESCRIPTION
 | 
						||
--		"A list of interface entries.  The number of entries is
 | 
						||
--		given by the value of ifNumber. This Table is an Ext of the
 | 
						||
--		standard ifTable located in the IF-MIB."
 | 
						||
--	::=  {  spc200MIB  2  }
 | 
						||
 | 
						||
 | 
						||
--ifEntryExt OBJECT-TYPE
 | 
						||
--	SYNTAX IfEntryExt
 | 
						||
--	MAX-ACCESS not-accessible
 | 
						||
--	STATUS current
 | 
						||
--	DESCRIPTION
 | 
						||
--		"An entry containing management information applicable to a
 | 
						||
--		particular interface. These entries are indexed using the ifIndex
 | 
						||
--		of the standard IF-MIB."
 | 
						||
--	INDEX { ifIndex }
 | 
						||
--	::= { ifTableExt 1 }
 | 
						||
 | 
						||
 | 
						||
--IfEntryExt ::= SEQUENCE {
 | 
						||
--	ifDefaultSpeed              Gauge32,
 | 
						||
--	ifSpeedAutoNegAdminStatus   INTEGER }
 | 
						||
	
 | 
						||
	
 | 
						||
--ifDefaultSpeed OBJECT-TYPE
 | 
						||
--	SYNTAX Gauge32
 | 
						||
--	MAX-ACCESS read-write
 | 
						||
--	STATUS current
 | 
						||
--	DESCRIPTION 
 | 
						||
--	        "This field is used to set the speed for a given interface.
 | 
						||
--	        It contains a default value which will be copied into ifSpeed if
 | 
						||
--	        the ifSpeedAutoNegAdminStatus is disabled"		
 | 
						||
--	::= { ifEntryExt 1 }	
 | 
						||
        
 | 
						||
       
 | 
						||
--ifSpeedAutoNegAdminStatus OBJECT-TYPE
 | 
						||
--	SYNTAX INTEGER {
 | 
						||
--			enabled(1),
 | 
						||
--			disabled(2) }
 | 
						||
--	MAX-ACCESS read-write
 | 
						||
--	STATUS current
 | 
						||
--	DESCRIPTION
 | 
						||
--	       "This field is used to enable/disable the speed auto negotiation 
 | 
						||
--	       process for a given interface. If the status is disabled, the user
 | 
						||
--	       can set the speed by setting ifDefaultSpeed.
 | 
						||
--	       When the speed auto negotiation status is enabled, the hardware 
 | 
						||
--	       select a speed and set it in ifSpeed. When the speed auto negotiation 
 | 
						||
--	       status is disabled, the content of ifDefaultSpeed is copied into 
 | 
						||
--	       ifSpeed."	        		
 | 
						||
--	::= { ifEntryExt 2 }                        
 | 
						||
 | 
						||
 | 
						||
--ifGroupExt OBJECT-GROUP
 | 
						||
--	OBJECTS {
 | 
						||
--		ifDefaultSpeed,
 | 
						||
--		ifSpeedAutoNegAdminStatus }
 | 
						||
--	STATUS current
 | 
						||
--	DESCRIPTION
 | 
						||
--		"The fields needed by the SPiDCOM functionalities"
 | 
						||
		
 | 
						||
--	::= { ifTableExt 2 }
 | 
						||
 | 
						||
 | 
						||
-- ipExt data , for DHCP mode
 | 
						||
 | 
						||
ipExt OBJECT-IDENTITY
 | 
						||
      STATUS  current
 | 
						||
      DESCRIPTION
 | 
						||
            "Extended ip needed for SPiDCOM functionalities"
 | 
						||
       ::= { spc200MIB 4 }
 | 
						||
 | 
						||
ipDynamic OBJECT-TYPE     
 | 
						||
       SYNTAX                  TruthValue
 | 
						||
       MAX-ACCESS              read-write
 | 
						||
       STATUS                  current
 | 
						||
       DESCRIPTION             "True if Ip address is set dynamically"
 | 
						||
       ::=  { ipExt 1  }
 | 
						||
 | 
						||
ipExtGroup OBJECT-GROUP
 | 
						||
       OBJECTS {
 | 
						||
		ipDynamic 
 | 
						||
		}
 | 
						||
       STATUS current
 | 
						||
       DESCRIPTION             "The fields needed by the SPiDCOM functionalities"		
 | 
						||
       ::= { ipExt 2 }
 | 
						||
 | 
						||
END
 |