5292 lines
		
	
	
		
			204 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			5292 lines
		
	
	
		
			204 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
DOCS-IF-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
  IMPORTS
 | 
						|
     MODULE-IDENTITY,
 | 
						|
     OBJECT-TYPE,
 | 
						|
     Unsigned32,
 | 
						|
     Integer32,
 | 
						|
     Counter32,
 | 
						|
     Counter64,
 | 
						|
     TimeTicks,
 | 
						|
     IpAddress,
 | 
						|
     transmission
 | 
						|
             FROM SNMPv2-SMI        -- [RFC2578]
 | 
						|
     TEXTUAL-CONVENTION,
 | 
						|
     MacAddress,
 | 
						|
     RowStatus,
 | 
						|
     TruthValue,
 | 
						|
     TimeInterval,
 | 
						|
     TimeStamp,
 | 
						|
     StorageType
 | 
						|
             FROM SNMPv2-TC         -- [RFC2579]
 | 
						|
     OBJECT-GROUP,
 | 
						|
     MODULE-COMPLIANCE
 | 
						|
             FROM SNMPv2-CONF       -- [RFC2580]
 | 
						|
     ifIndex, InterfaceIndexOrZero
 | 
						|
             FROM IF-MIB            -- [RFC2863]
 | 
						|
     InetAddressType,
 | 
						|
     InetAddress
 | 
						|
             FROM INET-ADDRESS-MIB  -- [RFC4001]
 | 
						|
     IANAifType
 | 
						|
             FROM IANAifType-MIB;   -- [IANA]
 | 
						|
 | 
						|
docsIfMib MODULE-IDENTITY
 | 
						|
     LAST-UPDATED    "200605240000Z" -- May 24, 2006
 | 
						|
     ORGANIZATION    "IETF IPCDN Working Group"
 | 
						|
     CONTACT-INFO
 | 
						|
         "        David Raftus
 | 
						|
          Postal: ATI Technologies Inc.
 | 
						|
                  340 Terry Fox Drive, Suite 202
 | 
						|
                  Ottawa Ontario
 | 
						|
                  Canada
 | 
						|
          Phone:  +1 613 592 1052 ext.222
 | 
						|
          E-mail: david.raftus@ati.com
 | 
						|
 | 
						|
                  Eduardo Cardona
 | 
						|
          Postal: Cable Television Laboratories, Inc.
 | 
						|
                  858 Coal Creek Circle
 | 
						|
                  Louisville, CO 80027-9750
 | 
						|
                  U.S.A.
 | 
						|
          Phone:  Tel:    +1 303 661 9100
 | 
						|
                  Fax:    +1 303 661 9199
 | 
						|
          E-mail: e.cardona@cablelabs.com;mibs@cablelabs.com
 | 
						|
 | 
						|
          IETF IPCDN Working Group
 | 
						|
          General Discussion: ipcdn@ietf.org
 | 
						|
          Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn
 | 
						|
          Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn
 | 
						|
          Co-chairs: Richard Woundy, Richard_Woundy@cable.comcast.com
 | 
						|
                     Jean-Francois Mule, jf.mule@cablelabs.com"
 | 
						|
     DESCRIPTION
 | 
						|
         "This is the MIB Module for DOCSIS 2.0-compliant Radio
 | 
						|
          Frequency (RF) interfaces in Cable Modems and
 | 
						|
          Cable Modem Termination Systems.
 | 
						|
 | 
						|
          Copyright (C) The Internet Society (2006).  This
 | 
						|
          version of this MIB module is part of RFC 4546; see
 | 
						|
          the RFC itself for full legal notices."
 | 
						|
 | 
						|
     REVISION        "200605240000Z"
 | 
						|
     DESCRIPTION
 | 
						|
         "Revision of the IETF RF MIB module for DOCSIS 2.0.
 | 
						|
          This version published as RFC 4546.
 | 
						|
          This MIB module revision includes the following
 | 
						|
          among others:
 | 
						|
          Usage of ifType (205) for upstream logical channels.
 | 
						|
          Addition of downstream and upstream utilization
 | 
						|
          counters.
 | 
						|
          Additional statistics per upstream interface.
 | 
						|
          Upstream channel offline configuration mechanism.
 | 
						|
          Added MIB support for new DOCSIS 2.0 modulation
 | 
						|
          attributes.
 | 
						|
          Euro-DOCSIS downstream interleave values.
 | 
						|
          Adjustments to RFC 2670 definitions based on
 | 
						|
          the MIB review guidelines from the IETF
 | 
						|
 | 
						|
          Operations and Management Area (OPS)."
 | 
						|
 | 
						|
     REVISION "199908190000Z"
 | 
						|
     DESCRIPTION
 | 
						|
         "Initial version, published as RFC 2670.
 | 
						|
          Modified by Mike St. Johns to fix problems identified by
 | 
						|
          the first pass of the MIB doctor.  Of special note,
 | 
						|
          docsIfRangingResp and docsIfCmtsInsertionInterval were
 | 
						|
          obsoleted and replaced by other objects with the same
 | 
						|
          functionality, but with more appropriate syntax."
 | 
						|
     ::= { transmission 127 }
 | 
						|
 | 
						|
-- Textual Conventions
 | 
						|
 | 
						|
TenthdBmV ::= TEXTUAL-CONVENTION
 | 
						|
     DISPLAY-HINT "d-1"
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "This data type represents power levels that are normally
 | 
						|
          expressed in dBmV.  Units are in tenths of a dBmV;
 | 
						|
          for example, 5.1 dBmV will be represented as 51."
 | 
						|
     SYNTAX       Integer32
 | 
						|
 | 
						|
TenthdB ::= TEXTUAL-CONVENTION
 | 
						|
     DISPLAY-HINT "d-1"
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "This data type represents power levels that are normally
 | 
						|
          expressed in dB.  Units are in tenths of a dB;
 | 
						|
          for example, 5.1 dB will be represented as 51."
 | 
						|
     SYNTAX       Integer32
 | 
						|
 | 
						|
DocsisVersion ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS          current
 | 
						|
    DESCRIPTION
 | 
						|
        "Indicates the DOCSIS Radio Frequency specification being
 | 
						|
         referenced.
 | 
						|
         'docsis10' indicates DOCSIS 1.0.
 | 
						|
         'docsis11' indicates DOCSIS 1.1.
 | 
						|
         'docsis20' indicates DOCSIS 2.0."
 | 
						|
    SYNTAX        INTEGER {
 | 
						|
         docsis10 (1),
 | 
						|
         docsis11 (2),
 | 
						|
         docsis20 (3)
 | 
						|
    }
 | 
						|
 | 
						|
DocsisQosVersion ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS          current
 | 
						|
    DESCRIPTION
 | 
						|
        "Indicates the referenced quality-of-service
 | 
						|
         level.
 | 
						|
         'docsis10 refers to DOCSIS 1.0 Class of
 | 
						|
         Service queuing services, and 'docsis11' refers
 | 
						|
         to DOCSIS 1.1 Quality of Service."
 | 
						|
    SYNTAX        INTEGER {
 | 
						|
        docsis10 (1),
 | 
						|
        docsis11 (2)
 | 
						|
    }
 | 
						|
 | 
						|
DocsisUpstreamType ::= TEXTUAL-CONVENTION
 | 
						|
    STATUS          current
 | 
						|
    DESCRIPTION
 | 
						|
         "Indicates the DOCSIS Upstream Channel Type.
 | 
						|
          'unknown' means information not available.
 | 
						|
          'tdma' is related to TDMA, Time Division
 | 
						|
          Multiple Access; 'atdma' is related to A-TDMA,
 | 
						|
          Advanced Time Division Multiple Access,
 | 
						|
          'scdma' is related to S-CDMA, Synchronous
 | 
						|
          Code Division Multiple Access.
 | 
						|
          'tdmaAndAtdma is related to simultaneous support of
 | 
						|
          TDMA and A-TDMA modes."
 | 
						|
    SYNTAX          INTEGER {
 | 
						|
        unknown(0),
 | 
						|
        tdma(1),
 | 
						|
        atdma(2),
 | 
						|
        scdma(3),
 | 
						|
        tdmaAndAtdma(4)
 | 
						|
    }
 | 
						|
 | 
						|
 DocsEqualizerData ::= TEXTUAL-CONVENTION
 | 
						|
      STATUS       current
 | 
						|
      DESCRIPTION
 | 
						|
          "This data type represents the equalizer data
 | 
						|
           as measured at the receiver interface.
 | 
						|
           The format of the equalizer follows the structure of the
 | 
						|
           Transmit Equalization Adjust RNG-RSP TLV of DOCSIS RFI
 | 
						|
           v2.0 :
 | 
						|
           1 byte Main tap location 1..(n + m)
 | 
						|
           1 byte Number of forward taps per symbol
 | 
						|
           1 byte Number of forward taps: n
 | 
						|
           1 byte Number of reverse taps: m
 | 
						|
 | 
						|
           Following are the equalizer coefficients:
 | 
						|
           First, forward taps coefficients:
 | 
						|
           2 bytes F1 (real),  2 bytes  F1 (imag)
 | 
						|
 | 
						|
           ...
 | 
						|
           2 bytes Fn (real),  2 bytes  Fn (imag)
 | 
						|
 | 
						|
           Then, reverse taps coefficients:
 | 
						|
           2 bytes D1 (real),  2 bytes  D1 (imag)
 | 
						|
           ...
 | 
						|
 | 
						|
           2 bytes Dm (real),  2 bytes  Dm (imag)
 | 
						|
 | 
						|
           The equalizer coefficients are considered signed 16-bit
 | 
						|
           integers in the range from -32768 (0x8000) to 32767
 | 
						|
           (0x7FFF).
 | 
						|
 | 
						|
           DOCSIS specifications require up to a maximum of
 | 
						|
           64 equalizer taps (n + m); therefore, this object size
 | 
						|
            can get up 260 bytes (4 + 4x64).
 | 
						|
           The minimum object size (other than zero) for a t-spaced
 | 
						|
           tap with a minimum of 8 symbols will be 36 (4 + 4x8)."
 | 
						|
      REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 8-23."
 | 
						|
      SYNTAX       OCTET STRING(SIZE (0 | 36..260))
 | 
						|
 | 
						|
docsIfMibObjects  OBJECT IDENTIFIER ::= { docsIfMib 1 }
 | 
						|
docsIfBaseObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 1 }
 | 
						|
docsIfCmObjects   OBJECT IDENTIFIER ::= { docsIfMibObjects 2 }
 | 
						|
docsIfCmtsObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 3 }
 | 
						|
 | 
						|
--
 | 
						|
-- BASE GROUP
 | 
						|
--
 | 
						|
 | 
						|
--
 | 
						|
-- The following table is implemented on both the Cable Modem
 | 
						|
-- and the Cable Modem Termination System.  This table is
 | 
						|
-- read only for the CM.
 | 
						|
--
 | 
						|
 | 
						|
docsIfDownstreamChannelTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfDownstreamChannelEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This table describes the attributes of downstream
 | 
						|
          channels (frequency bands)."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-16, and 6-17."
 | 
						|
     ::= { docsIfBaseObjects 1 }
 | 
						|
 | 
						|
docsIfDownstreamChannelEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfDownstreamChannelEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "An entry provides a list of attributes for a single
 | 
						|
          downstream channel.
 | 
						|
          An entry in this table exists for each ifEntry with an
 | 
						|
          ifType of docsCableDownstream(128)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfDownstreamChannelTable 1 }
 | 
						|
 | 
						|
DocsIfDownstreamChannelEntry ::= SEQUENCE {
 | 
						|
         docsIfDownChannelId               Integer32,
 | 
						|
         docsIfDownChannelFrequency        Integer32,
 | 
						|
         docsIfDownChannelWidth            Integer32,
 | 
						|
         docsIfDownChannelModulation       INTEGER,
 | 
						|
         docsIfDownChannelInterleave       INTEGER,
 | 
						|
         docsIfDownChannelPower            TenthdBmV,
 | 
						|
         docsIfDownChannelAnnex            INTEGER,
 | 
						|
         docsIfDownChannelStorageType      StorageType
 | 
						|
     }
 | 
						|
 | 
						|
docsIfDownChannelId OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The Cable Modem Termination System identification of the
 | 
						|
          downstream channel within this particular MAC interface.
 | 
						|
          if the interface is down, the object returns the most
 | 
						|
          current value.  If the downstream channel ID is unknown,
 | 
						|
          this object returns a value of 0."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 1 }
 | 
						|
 | 
						|
docsIfDownChannelFrequency OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..1000000000)
 | 
						|
     UNITS       "hertz"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The center of the downstream frequency associated with
 | 
						|
          this channel.  This object will return the current tuner
 | 
						|
 | 
						|
          frequency.  If a CMTS provides IF output, this object
 | 
						|
          will return 0, unless this CMTS is in control of the
 | 
						|
          final downstream frequency.  See the associated
 | 
						|
          compliance object for a description of valid frequencies
 | 
						|
          that may be written to this object."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.3.3."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 2 }
 | 
						|
 | 
						|
docsIfDownChannelWidth OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16000000)
 | 
						|
     UNITS       "hertz"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The bandwidth of this downstream channel.  Most
 | 
						|
          implementations are expected to support a channel width
 | 
						|
          of 6 MHz (North America) and/or 8 MHz (Europe).  See the
 | 
						|
          associated compliance object for a description of the
 | 
						|
          valid channel widths for this object."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 6-17."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 3 }
 | 
						|
 | 
						|
docsIfDownChannelModulation OBJECT-TYPE
 | 
						|
     SYNTAX      INTEGER {
 | 
						|
         unknown(1),
 | 
						|
         other(2),
 | 
						|
         qam64(3),
 | 
						|
         qam256(4)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The modulation type associated with this downstream
 | 
						|
          channel.  If the interface is down, this object either
 | 
						|
          returns the configured value (CMTS), the most current
 | 
						|
          value (CM), or the value of unknown(1).  See the
 | 
						|
          associated conformance object for write conditions and
 | 
						|
          limitations.  See the reference for specifics on the
 | 
						|
          modulation profiles implied by qam64 and qam256."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 6-17."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 4 }
 | 
						|
 | 
						|
docsIfDownChannelInterleave OBJECT-TYPE
 | 
						|
     SYNTAX      INTEGER {
 | 
						|
         unknown(1),
 | 
						|
         other(2),
 | 
						|
         taps8Increment16(3),
 | 
						|
         taps16Increment8(4),
 | 
						|
         taps32Increment4(5),
 | 
						|
         taps64Increment2(6),
 | 
						|
         taps128Increment1(7),
 | 
						|
         taps12increment17(8)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The Forward Error Correction (FEC) interleaving used
 | 
						|
          for this downstream channel.
 | 
						|
          Values are defined as follows:
 | 
						|
          taps8Increment16(3):   protection 5.9/4.1 usec,
 | 
						|
                                 latency .22/.15 msec
 | 
						|
          taps16Increment8(4):   protection 12/8.2 usec,
 | 
						|
                                 latency .48/.33 msec
 | 
						|
          taps32Increment4(5):   protection 24/16 usec,
 | 
						|
                                 latency .98/.68 msec
 | 
						|
          taps64Increment2(6):   protection 47/33 usec,
 | 
						|
                                 latency 2/1.4 msec
 | 
						|
          taps128Increment1(7):  protection 95/66 usec,
 | 
						|
                                 latency 4/2.8 msec
 | 
						|
          taps12increment17(8):  protection 18/14 usec,
 | 
						|
                                 latency 0.43/0.32 msec
 | 
						|
 | 
						|
         The value 'taps12increment17' is supported by EuroDOCSIS
 | 
						|
         cable systems only, and the others by DOCSIS cable systems.
 | 
						|
 | 
						|
          If the interface is down, this object either returns
 | 
						|
          the configured value (CMTS), the most current value (CM),
 | 
						|
          or the value of unknown(1).
 | 
						|
          The value of other(2) is returned if the interleave
 | 
						|
          is known but not defined in the above list.
 | 
						|
          See the associated conformance object for write
 | 
						|
          conditions and limitations.  See the reference for the FEC
 | 
						|
          configuration described by the setting of this object."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 6-15."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 5 }
 | 
						|
 | 
						|
docsIfDownChannelPower OBJECT-TYPE
 | 
						|
     SYNTAX      TenthdBmV
 | 
						|
     UNITS       "dBmV"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CMTS, the operational transmit power.  At the CM,
 | 
						|
          the received power level.
 | 
						|
          If the interface is down, this object either returns
 | 
						|
          the configured value (CMTS), the most current value (CM)
 | 
						|
          or the value of 0.  See the associated conformance object
 | 
						|
          for write conditions and limitations.  See the reference
 | 
						|
          for recommended and required power levels."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-16, 6-17."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 6 }
 | 
						|
 | 
						|
docsIfDownChannelAnnex OBJECT-TYPE
 | 
						|
     SYNTAX      INTEGER {
 | 
						|
         unknown(1),
 | 
						|
         other(2),
 | 
						|
         annexA(3),
 | 
						|
         annexB(4),
 | 
						|
         annexC(5)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The value of this object indicates the conformance of
 | 
						|
          the implementation to important regional cable standards.
 | 
						|
          annexA : Annex A from ITU-T J.83 is used.
 | 
						|
                   (equivalent to EN 300 429)
 | 
						|
          annexB : Annex B from ITU-T J.83 is used.
 | 
						|
          annexC : Annex C from ITU-T J.83 is used."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 6.3.1, and H.3.1."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 7 }
 | 
						|
 | 
						|
docsIfDownChannelStorageType OBJECT-TYPE
 | 
						|
     SYNTAX       StorageType
 | 
						|
     MAX-ACCESS   read-only
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "The storage type for this conceptual row.
 | 
						|
          Entries with this object set to permanent(4)
 | 
						|
          do not require write operations for read-write
 | 
						|
          objects."
 | 
						|
     ::= { docsIfDownstreamChannelEntry 8 }
 | 
						|
 | 
						|
--
 | 
						|
-- The following table is implemented on both the CM and the CMTS.
 | 
						|
-- For the CM, only attached channels appear in the table.  For the
 | 
						|
-- CM, this table is read-only as well.
 | 
						|
--
 | 
						|
 | 
						|
docsIfUpstreamChannelTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfUpstreamChannelEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This table describes the attributes of attached upstream
 | 
						|
          channels."
 | 
						|
     ::= { docsIfBaseObjects 2 }
 | 
						|
 | 
						|
docsIfUpstreamChannelEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfUpstreamChannelEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "List of attributes for a single upstream channel.  For
 | 
						|
          DOCSIS 2.0 CMTSs, an entry in this table exists for
 | 
						|
          each ifEntry with an ifType of docsCableUpstreamChannel
 | 
						|
          (205).
 | 
						|
          For DOCSIS 1.x CM/CMTSs and DOCSIS 2.0 CMs, an entry in
 | 
						|
          this table exists for each ifEntry with an ifType of
 | 
						|
          docsCableUpstream (129).
 | 
						|
 | 
						|
          For DOCSIS 2.0 CMTSs, two classes of interfaces can be
 | 
						|
          defined for this table:
 | 
						|
           o Upstream Physical Interfaces: The traditional DOCSIS
 | 
						|
             1.x CMTS upstream interface ifType 129 and the DOCSIS
 | 
						|
             2.0 ifType 205 that are functional.  In other words,
 | 
						|
             interfaces that represent upstream receivers within
 | 
						|
             an RF MAC interface.
 | 
						|
             Entries of physical interfaces are exposed to the
 | 
						|
             management interface with their corresponding
 | 
						|
             ifStack hierarchy and are not administratively
 | 
						|
             created by this table.
 | 
						|
 | 
						|
           o Upstream Temporary Interfaces: A fictitious
 | 
						|
             interface created for the purpose of manipulating
 | 
						|
             physical interface parameters offline, then
 | 
						|
             validating prior to updating the target physical
 | 
						|
             interface.
 | 
						|
 | 
						|
          In case of a reinitialization of the managed system,
 | 
						|
          physical interfaces values persist while the temporary
 | 
						|
          interfaces are not recreated.
 | 
						|
 | 
						|
          This mechanism helps to minimize service disruptions
 | 
						|
          originating in situations where a group of interface
 | 
						|
          parameter values need to be consistent with each other
 | 
						|
          in SET operations.  A temporary buffer
 | 
						|
          (temporary interface) is provided to allow the CMTS
 | 
						|
          to validate the parameters offline."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfUpstreamChannelTable 1 }
 | 
						|
 | 
						|
DocsIfUpstreamChannelEntry ::= SEQUENCE {
 | 
						|
         docsIfUpChannelId                     Integer32,
 | 
						|
         docsIfUpChannelFrequency              Integer32,
 | 
						|
         docsIfUpChannelWidth                  Integer32,
 | 
						|
         docsIfUpChannelModulationProfile      Unsigned32,
 | 
						|
         docsIfUpChannelSlotSize               Unsigned32,
 | 
						|
         docsIfUpChannelTxTimingOffset         Unsigned32,
 | 
						|
         docsIfUpChannelRangingBackoffStart    Integer32,
 | 
						|
         docsIfUpChannelRangingBackoffEnd      Integer32,
 | 
						|
         docsIfUpChannelTxBackoffStart         Integer32,
 | 
						|
         docsIfUpChannelTxBackoffEnd           Integer32,
 | 
						|
         docsIfUpChannelScdmaActiveCodes       Unsigned32,
 | 
						|
         docsIfUpChannelScdmaCodesPerSlot      Integer32,
 | 
						|
         docsIfUpChannelScdmaFrameSize         Unsigned32,
 | 
						|
         docsIfUpChannelScdmaHoppingSeed       Unsigned32,
 | 
						|
         docsIfUpChannelType                   DocsisUpstreamType,
 | 
						|
         docsIfUpChannelCloneFrom              InterfaceIndexOrZero,
 | 
						|
         docsIfUpChannelUpdate                 TruthValue,
 | 
						|
         docsIfUpChannelStatus                 RowStatus,
 | 
						|
         docsIfUpChannelPreEqEnable            TruthValue
 | 
						|
     }
 | 
						|
 | 
						|
docsIfUpChannelId OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The CMTS identification of the upstream channel."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 1 }
 | 
						|
 | 
						|
docsIfUpChannelFrequency OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..1000000000)
 | 
						|
     UNITS       "hertz"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The center of the frequency band associated with this
 | 
						|
          upstream interface.  This object returns 0 if the frequency
 | 
						|
          is undefined or unknown.  Minimum permitted upstream
 | 
						|
          frequency is 5,000,000 Hz for current technology.  See
 | 
						|
          the associated conformance object for write conditions
 | 
						|
          and limitations."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 4-2."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 2 }
 | 
						|
 | 
						|
docsIfUpChannelWidth OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..64000000)
 | 
						|
     UNITS       "hertz"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The bandwidth of this upstream interface.  This object
 | 
						|
          returns 0 if the interface width is undefined or unknown.
 | 
						|
          Minimum permitted interface width is currently 200,000 Hz.
 | 
						|
          See the associated conformance object for write conditions
 | 
						|
          and limitations."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 6-5."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 3 }
 | 
						|
 | 
						|
docsIfUpChannelModulationProfile OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "An entry identical to the docsIfModIndex in the
 | 
						|
          docsIfCmtsModulationTable that describes this channel.
 | 
						|
          This channel is further instantiated there by a grouping
 | 
						|
          of interval usage codes (IUCs) that, together, fully
 | 
						|
          describe the channel modulation.  This object returns 0 if
 | 
						|
          the docsIfCmtsModulationTable entry does not exist or is
 | 
						|
          empty.  See the associated conformance object for write
 | 
						|
          conditions and limitations.
 | 
						|
 | 
						|
          Setting this object returns an 'inconsistentValue'
 | 
						|
          error if the following conditions are not satisfied:
 | 
						|
          1. All the IUC entries in the selected modulation profile
 | 
						|
          MUST have the same value of docsIfCmtsModChannelType.
 | 
						|
          2. All of the Modulation parameters in the selected
 | 
						|
          modulation profile MUST be consistent with the other
 | 
						|
          parameters in this docsIfUpstreamChannelEntry."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 8-19."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 4 }
 | 
						|
 | 
						|
docsIfUpChannelSlotSize OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     UNITS       "ticks"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Applicable to TDMA and ATDMA channel types only.
 | 
						|
          The number of 6.25 microsecond ticks in each upstream
 | 
						|
          mini-slot.  Returns zero if the value is undefined or
 | 
						|
          unknown or in case of an SCDMA channel.
 | 
						|
          See the associated conformance object for write
 | 
						|
          conditions and limitations."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.1.2.4."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 5 }
 | 
						|
 | 
						|
docsIfUpChannelTxTimingOffset OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CM, a measure of the current round trip time
 | 
						|
          obtained from the ranging offset (initial ranging offset +
 | 
						|
          ranging offset adjustments).
 | 
						|
          At the CMTS, the maximum of timing offset, among all the
 | 
						|
          CMs that are/were present on the channel, taking into
 | 
						|
          account all ( initial + periodic ) timing offset
 | 
						|
          corrections that were sent for each of the CMs.  Generally,
 | 
						|
          these measurements are positive, but if the measurements
 | 
						|
          are negative, the value of this object is zero.  Used for
 | 
						|
          timing of CM upstream transmissions to ensure synchronized
 | 
						|
          arrivals at the CMTS.
 | 
						|
          Units are one 64th fraction of 6.25 microseconds."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.19."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 6 }
 | 
						|
 | 
						|
docsIfUpChannelRangingBackoffStart OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The initial random backoff window to use when retrying
 | 
						|
          Ranging Requests.  Expressed as a power of 2.  A value of
 | 
						|
          16 at the CMTS indicates that a proprietary adaptive retry
 | 
						|
          mechanism is to be used.  See the associated conformance
 | 
						|
          object for write conditions and limitations."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 8.3.4, and 9.4."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 7 }
 | 
						|
 | 
						|
docsIfUpChannelRangingBackoffEnd OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The final random backoff window to use when retrying
 | 
						|
          Ranging Requests.  Expressed as a power of 2.  A value of
 | 
						|
          16 at the CMTS indicates that a proprietary adaptive retry
 | 
						|
          mechanism is to be used.  See the associated conformance
 | 
						|
          object for write conditions and limitations."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.4, and 9.4."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 8 }
 | 
						|
 | 
						|
docsIfUpChannelTxBackoffStart OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The initial random backoff window to use when retrying
 | 
						|
          transmissions.  Expressed as a power of 2.  A value of 16
 | 
						|
          at the CMTS indicates that a proprietary adaptive retry
 | 
						|
          mechanism is to be used.  See the associated conformance
 | 
						|
          object for write conditions and limitations."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.4, and 9.4."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 9 }
 | 
						|
 | 
						|
docsIfUpChannelTxBackoffEnd OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The final random backoff window to use when retrying
 | 
						|
          transmissions.  Expressed as a power of 2.  A value of 16
 | 
						|
          at the CMTS indicates that a proprietary adaptive retry
 | 
						|
          mechanism is to be used.  See the associated conformance
 | 
						|
          object for write conditions and limitations."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.4, and 9.4."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 10 }
 | 
						|
 | 
						|
docsIfUpChannelScdmaActiveCodes OBJECT-TYPE
 | 
						|
     SYNTAX     Unsigned32 (0|64..66|68..70|72|74..78|80..82|84..88
 | 
						|
                             |90..96|98..100|102|104..106|108
 | 
						|
                             |110..112|114..126|128)
 | 
						|
     MAX-ACCESS read-create
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "Applicable for SCDMA channel types only.
 | 
						|
          Number of active codes.  Returns zero for
 | 
						|
          Non-SCDMA channel types.  Note that legal
 | 
						|
          values from 64..128 MUST be non-prime."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.11.2.1."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 11 }
 | 
						|
 | 
						|
docsIfUpChannelScdmaCodesPerSlot OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32(0 | 2..32)
 | 
						|
     UNITS       "codesperMinislots"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Applicable for SCDMA channel types only.
 | 
						|
          The number of SCDMA codes per mini-slot.
 | 
						|
          Returns zero if the value is undefined or unknown or in
 | 
						|
 | 
						|
          case of a TDMA or ATDMA channel."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.11.2.1."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 12 }
 | 
						|
 | 
						|
docsIfUpChannelScdmaFrameSize OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32 (0..32)
 | 
						|
     UNITS       "spreadIntervals"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Applicable for SCDMA channel types only.
 | 
						|
          SCDMA Frame size in units of spreading intervals.
 | 
						|
          This value returns zero for non-SCDMA Profiles."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.12."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 13 }
 | 
						|
 | 
						|
docsIfUpChannelScdmaHoppingSeed OBJECT-TYPE
 | 
						|
     SYNTAX     Unsigned32 (0..32767)
 | 
						|
     MAX-ACCESS read-create
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "Applicable for SCDMA channel types only.
 | 
						|
          15-bit seed used for code hopping sequence initialization.
 | 
						|
          Returns zero for non-SCDMA channel types.
 | 
						|
          Setting this value to a value different than zero for
 | 
						|
          non-SCDMA channel types returns the error 'wrongValue'."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.14.1."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 14 }
 | 
						|
 | 
						|
docsIfUpChannelType OBJECT-TYPE
 | 
						|
     SYNTAX      DocsisUpstreamType
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Reflects the Upstream channel type.
 | 
						|
          This object returns the value of docsIfCmtsModChannelType
 | 
						|
          for the modulation profile selected in
 | 
						|
          docsIfUpChannelModulationProfile for this row."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.1."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 15 }
 | 
						|
 | 
						|
docsIfUpChannelCloneFrom OBJECT-TYPE
 | 
						|
     SYNTAX      InterfaceIndexOrZero
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object contains the ifIndex value of the physical
 | 
						|
          interface row entry whose parameters are to be adjusted.
 | 
						|
 | 
						|
          Upon setting this object to the ifIndex value of a
 | 
						|
          physical interface, the following interface objects values
 | 
						|
          are copied to this entry:
 | 
						|
          docsIfUpChannelFrequency,
 | 
						|
          docsIfUpChannelWidth,
 | 
						|
          docsIfUpChannelModulationProfile,
 | 
						|
          docsIfUpChannelSlotSize,
 | 
						|
          docsIfUpChannelRangingBackoffStart,
 | 
						|
          docsIfUpChannelRangingBackoffEnd,
 | 
						|
          docsIfUpChannelTxBackoffStart,
 | 
						|
          docsIfUpChannelTxBackoffEnd,
 | 
						|
          docsIfUpChannelScdmaActiveCodes,
 | 
						|
          docsIfUpChannelScdmaCodesPerSlot,
 | 
						|
          docsIfUpChannelScdmaFrameSize,
 | 
						|
          docsIfUpChannelScdmaHoppingSeed,
 | 
						|
          docsIfUpChannelType, and
 | 
						|
          docsIfUpChannelPreEqEnable
 | 
						|
          Setting this object to the value of a non-existent or
 | 
						|
          a temporary upstream interface returns the error
 | 
						|
          'wrongValue'.
 | 
						|
          This object MUST contain a value of zero for physical
 | 
						|
          interfaces entries.
 | 
						|
          Setting this object in row entries that correspond to
 | 
						|
          physical interfaces returns the error 'wrongValue'."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 16 }
 | 
						|
 | 
						|
docsIfUpChannelUpdate OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Used to perform the copy of adjusted parameters from the
 | 
						|
          temporary interface entry to the physical interface
 | 
						|
          indicated by the docsIfUpChannelCloneFrom object.  The
 | 
						|
          transfer is initiated through an SNMP SET to 'true' of
 | 
						|
 | 
						|
          this object.
 | 
						|
          A SET to 'true' fails and returns error 'commitFailed'
 | 
						|
          if docsIfUpChannelStatus value is 'notInService', which
 | 
						|
          means that the interface parameters values are not
 | 
						|
          compatible with each other or have not been validated yet.
 | 
						|
          Reading this object always returns 'false'."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 17 }
 | 
						|
 | 
						|
docsIfUpChannelStatus OBJECT-TYPE
 | 
						|
     SYNTAX      RowStatus
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is only used for the creation of a temporary
 | 
						|
          upstream row with the purpose of updating the parameters
 | 
						|
          of a physical upstream channel entry.
 | 
						|
 | 
						|
          The following restrictions apply to this object:
 | 
						|
          1. This object is not writable for physical interfaces.
 | 
						|
          2. Temporary interface entries are only created by a SET
 | 
						|
             of this object to createandWait(5).
 | 
						|
          3. ifAdminStatus from the Interface MIB RFC 2863 is used
 | 
						|
             to take a physical upstream channel offline, to be
 | 
						|
             consistent with DOCSIS 1.x operation, as indicated in
 | 
						|
             RFC 2670.
 | 
						|
             In addition,
 | 
						|
              o ifAdminStatus 'down' is reflected in this object
 | 
						|
                as 'notInService'.
 | 
						|
              o ifOperStatus 'down' while ifAdminStatus 'up' is
 | 
						|
                reflected in this object as 'notInservice'.
 | 
						|
          4. Temporary created rows MUST be set to 'active' with
 | 
						|
             the purpose of validating upstream parameter
 | 
						|
             consistency prior to transferring the parameters to the
 | 
						|
             physical interface.
 | 
						|
 | 
						|
          Below is a mandatory procedure for adjusting the values
 | 
						|
          of a physical interface:
 | 
						|
          1. Create a temporary interface entry through an SNMP SET
 | 
						|
             using 'createAndWait'.  At this point, the RowStatus
 | 
						|
             reports 'notReady'.
 | 
						|
             The Manager entity uses an ifIndex value outside the
 | 
						|
             operational range of the physical interfaces for the
 | 
						|
             creation of a temporary interface.
 | 
						|
          2. Set the docsIfUpChannelCloneFrom object to the ifIndex
 | 
						|
             value of the physical row to update.  Now
 | 
						|
             docsIfUpChannelStatus reports 'notInService'.
 | 
						|
          3. Change the upstream parameters to the desired values
 | 
						|
             in the temporary row.
 | 
						|
 | 
						|
          4. Validate that all parameters are consistent by setting
 | 
						|
             docsIfUpChannelStatus to 'active'.  A failure to set the
 | 
						|
             RowStatus to 'active' returns the error 'commitFailed',
 | 
						|
             which means the parameters are not compatible with the
 | 
						|
             target physical interface.
 | 
						|
          5. With docsIfUpChannelStatus 'active', transfer the
 | 
						|
             parameters to the target physical interface by setting
 | 
						|
             the object docsIfUpChannelUpdate to 'true'.
 | 
						|
          6. Delete the temporary row by setting
 | 
						|
             docsIfUpChannelStatus to 'destroy'."
 | 
						|
     ::= { docsIfUpstreamChannelEntry 18 }
 | 
						|
 | 
						|
docsIfUpChannelPreEqEnable OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CMTS, this object is used to enable or disable
 | 
						|
          pre-equalization on the upstream channel represented by
 | 
						|
          this table instance.  At the CM, this object is read-only
 | 
						|
          and reflects the status of pre-equalization as represented
 | 
						|
          in the RNG-RSP.  Pre-equalization is considered enabled at
 | 
						|
          the CM if a RNG-RSP with pre-equalization data has been
 | 
						|
          received at least once since the last mac
 | 
						|
          reinitialization."
 | 
						|
     DEFVAL {false}
 | 
						|
     ::= { docsIfUpstreamChannelEntry 19 }
 | 
						|
 | 
						|
-- The following table describes the attributes of each class of
 | 
						|
-- service.  The entries in this table are referenced from the
 | 
						|
-- docsIfServiceEntries.  They exist as a separate table in order to
 | 
						|
-- reduce redundant information in docsIfServiceTable.
 | 
						|
--
 | 
						|
-- This table is implemented at both the CM and the CMTS.
 | 
						|
-- The CM need only maintain entries for the classes of service
 | 
						|
-- referenced by its docsIfCmServiceTable.
 | 
						|
--
 | 
						|
 | 
						|
docsIfQosProfileTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfQosProfileEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes for each class of service."
 | 
						|
     ::= { docsIfBaseObjects 3 }
 | 
						|
 | 
						|
docsIfQosProfileEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfQosProfileEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes for a single class of service.
 | 
						|
          If implemented as read-create in the Cable Modem
 | 
						|
          Termination System, creation of entries in this table is
 | 
						|
          controlled by the value of
 | 
						|
          docsIfCmtsQosProfilePermissions.
 | 
						|
 | 
						|
          If implemented as read-only, entries are created based
 | 
						|
          on information in REG-REQ MAC messages received from
 | 
						|
          cable modems (for Cable Modem Termination System), or
 | 
						|
          based on information extracted from the TFTP option file
 | 
						|
          (for Cable Modem).
 | 
						|
          In the Cable Modem Termination System, read-only entries
 | 
						|
          are removed if no longer referenced by
 | 
						|
          docsIfCmtsServiceTable.
 | 
						|
 | 
						|
          An entry in this table MUST not be removed while it is
 | 
						|
          referenced by an entry in docsIfCmServiceTable (Cable
 | 
						|
          Modem) or docsIfCmtsServiceTable (Cable Modem Termination
 | 
						|
          System).
 | 
						|
 | 
						|
          An entry in this table SHOULD NOT be changeable while
 | 
						|
          it is referenced by an entry in docsIfCmtsServiceTable.
 | 
						|
 | 
						|
          If this table is created automatically, there SHOULD only
 | 
						|
          be a single entry for each Class of Service.  Multiple
 | 
						|
          entries with the same Class of Service parameters are NOT
 | 
						|
          RECOMMENDED."
 | 
						|
     INDEX { docsIfQosProfIndex }
 | 
						|
     ::= { docsIfQosProfileTable 1 }
 | 
						|
 | 
						|
DocsIfQosProfileEntry ::= SEQUENCE {
 | 
						|
         docsIfQosProfIndex                Integer32,
 | 
						|
         docsIfQosProfPriority             Integer32,
 | 
						|
         docsIfQosProfMaxUpBandwidth       Integer32,
 | 
						|
         docsIfQosProfGuarUpBandwidth      Integer32,
 | 
						|
         docsIfQosProfMaxDownBandwidth     Integer32,
 | 
						|
         docsIfQosProfMaxTxBurst           Integer32,  -- deprecated
 | 
						|
         docsIfQosProfBaselinePrivacy      TruthValue,
 | 
						|
         docsIfQosProfStatus               RowStatus,
 | 
						|
         docsIfQosProfMaxTransmitBurst     Integer32,
 | 
						|
         docsIfQosProfStorageType          StorageType
 | 
						|
     }
 | 
						|
 | 
						|
docsIfQosProfIndex OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..16383)
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The index value that uniquely identifies an entry
 | 
						|
          in the docsIfQosProfileTable."
 | 
						|
     ::= { docsIfQosProfileEntry 1 }
 | 
						|
 | 
						|
docsIfQosProfPriority OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..7)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "A relative priority assigned to this service when
 | 
						|
          allocating bandwidth.  Zero indicates lowest priority
 | 
						|
          and seven indicates highest priority.
 | 
						|
          Interpretation of priority is device-specific.
 | 
						|
          MUST NOT be changed while this row is active."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex C.1.1.4."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfQosProfileEntry 2 }
 | 
						|
 | 
						|
docsIfQosProfMaxUpBandwidth OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..100000000)
 | 
						|
     UNITS "bits per second"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The maximum upstream bandwidth, in bits per second,
 | 
						|
          allowed for a service with this service class.
 | 
						|
          Zero if there is no restriction of upstream bandwidth.
 | 
						|
          MUST NOT be changed while this row is active."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex C.1.1.4."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfQosProfileEntry 3 }
 | 
						|
 | 
						|
docsIfQosProfGuarUpBandwidth OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..100000000)
 | 
						|
     UNITS "bits per second"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Minimum guaranteed upstream bandwidth, in bits per second,
 | 
						|
          allowed for a service with this service class.
 | 
						|
          MUST NOT be changed while this row is active."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex C.1.1.4."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfQosProfileEntry 4 }
 | 
						|
 | 
						|
docsIfQosProfMaxDownBandwidth OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..100000000)
 | 
						|
     UNITS "bits per second"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The maximum downstream bandwidth, in bits per second,
 | 
						|
          allowed for a service with this service class.
 | 
						|
          Zero if there is no restriction of downstream bandwidth.
 | 
						|
          MUST NOT be changed while this row is active."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex C.1.1.4."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfQosProfileEntry 5 }
 | 
						|
 | 
						|
docsIfQosProfMaxTxBurst OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     UNITS "mini-slots"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      deprecated
 | 
						|
     DESCRIPTION
 | 
						|
         "The maximum number of mini-slots that may be requested
 | 
						|
          for a single upstream transmission.
 | 
						|
          A value of zero means there is no limit.
 | 
						|
          MUST NOT be changed while this row is active.
 | 
						|
          This object has been deprecated and replaced by
 | 
						|
          docsIfQosProfMaxTransmitBurst, to fix a mismatch
 | 
						|
          of the units and value range with respect to the DOCSIS
 | 
						|
          Maximum Upstream Channel Transmit Burst Configuration
 | 
						|
          Setting."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          C.1.1.4."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfQosProfileEntry 6 }
 | 
						|
 | 
						|
docsIfQosProfBaselinePrivacy OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Indicates whether Baseline Privacy is enabled for this
 | 
						|
          service class.
 | 
						|
          MUST NOT be changed while this row is active."
 | 
						|
     DEFVAL { false }
 | 
						|
     ::= { docsIfQosProfileEntry 7 }
 | 
						|
 | 
						|
docsIfQosProfStatus OBJECT-TYPE
 | 
						|
     SYNTAX      RowStatus
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This is object is used to create or delete rows in
 | 
						|
          this table.  This object MUST NOT be changed from active
 | 
						|
          while the row is referenced by any entry in either
 | 
						|
          docsIfCmServiceTable (on the CM) or
 | 
						|
          docsIfCmtsServiceTable (on the CMTS)."
 | 
						|
     ::= { docsIfQosProfileEntry 8 }
 | 
						|
 | 
						|
docsIfQosProfMaxTransmitBurst OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..65535)
 | 
						|
     UNITS       "bytes"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The maximum number of bytes that may be requested for a
 | 
						|
          single upstream transmission.  A value of zero means there
 | 
						|
          is no limit.  Note: This value does not include any
 | 
						|
          physical layer overhead.
 | 
						|
          MUST NOT be changed while this row is active."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex C.1.1.4."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfQosProfileEntry 9 }
 | 
						|
 | 
						|
docsIfQosProfStorageType OBJECT-TYPE
 | 
						|
     SYNTAX       StorageType
 | 
						|
     MAX-ACCESS   read-only
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "The storage type for this conceptual row.
 | 
						|
          Entries with this object set to permanent(4)
 | 
						|
 | 
						|
          do not require write operations for writable
 | 
						|
          objects."
 | 
						|
     ::= { docsIfQosProfileEntry 10 }
 | 
						|
 | 
						|
docsIfSignalQualityTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfSignalQualityEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CM, describes the PHY signal quality of downstream
 | 
						|
          channels.  At the CMTS, this object describes the PHY
 | 
						|
          signal quality of upstream channels.  At the CMTS, this
 | 
						|
          table MAY exclude contention intervals."
 | 
						|
     ::= { docsIfBaseObjects 4 }
 | 
						|
 | 
						|
docsIfSignalQualityEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfSignalQualityEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CM, this object describes the PHY characteristics of
 | 
						|
          a downstream channel.  At the CMTS, it describes the PHY
 | 
						|
          signal quality of an upstream channel.
 | 
						|
          An entry in this table exists for each ifEntry with an
 | 
						|
          ifType of docsCableDownstream(128) for Cable Modems.
 | 
						|
          For DOCSIS 1.1 Cable Modem Termination Systems, an entry
 | 
						|
          exists for each ifEntry with an ifType of
 | 
						|
          docsCableUpstream (129).
 | 
						|
          For DOCSIS 2.0 Cable Modem Termination Systems, an entry
 | 
						|
          exists for each ifEntry with an ifType of
 | 
						|
          docsCableUpstreamChannel (205)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfSignalQualityTable 1 }
 | 
						|
 | 
						|
DocsIfSignalQualityEntry ::= SEQUENCE {
 | 
						|
         docsIfSigQIncludesContention  TruthValue,
 | 
						|
         docsIfSigQUnerroreds          Counter32,
 | 
						|
         docsIfSigQCorrecteds          Counter32,
 | 
						|
         docsIfSigQUncorrectables      Counter32,
 | 
						|
         docsIfSigQSignalNoise         TenthdB,
 | 
						|
         docsIfSigQMicroreflections    Integer32,
 | 
						|
         docsIfSigQEqualizationData    DocsEqualizerData,
 | 
						|
         docsIfSigQExtUnerroreds       Counter64,
 | 
						|
         docsIfSigQExtCorrecteds       Counter64,
 | 
						|
         docsIfSigQExtUncorrectables   Counter64
 | 
						|
     }
 | 
						|
 | 
						|
docsIfSigQIncludesContention OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "true(1) if this CMTS includes contention intervals in
 | 
						|
          the counters in this table.  Always false(2) for CMs."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4.1"
 | 
						|
     ::= { docsIfSignalQualityEntry 1 }
 | 
						|
 | 
						|
docsIfSigQUnerroreds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received on this channel without error.
 | 
						|
          This includes all codewords, whether or not they
 | 
						|
          were part of frames destined for this device.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 6.2.4, and 6.3.6."
 | 
						|
     ::= { docsIfSignalQualityEntry 2 }
 | 
						|
 | 
						|
docsIfSigQCorrecteds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received on this channel with correctable
 | 
						|
          errors.  This includes all codewords, whether or not
 | 
						|
          they were part of frames destined for this device.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 6.2.4, and 6.3.6."
 | 
						|
     ::= { docsIfSignalQualityEntry 3 }
 | 
						|
 | 
						|
docsIfSigQUncorrectables OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received on this channel with uncorrectable
 | 
						|
          errors.  This includes all codewords, whether or not
 | 
						|
          they were part of frames destined for this device.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 6.2.4, and 6.3.6."
 | 
						|
     ::= { docsIfSignalQualityEntry 4 }
 | 
						|
 | 
						|
docsIfSigQSignalNoise OBJECT-TYPE
 | 
						|
     SYNTAX      TenthdB
 | 
						|
     UNITS       "TenthdB"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Signal/Noise ratio as perceived for this channel.
 | 
						|
          At the CM, this object  describes the Signal/Noise of the
 | 
						|
          downstream channel.  At the CMTS, it describes the
 | 
						|
          average Signal/Noise of the upstream channel."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 4-1 and 4-2"
 | 
						|
     ::= { docsIfSignalQualityEntry 5 }
 | 
						|
 | 
						|
docsIfSigQMicroreflections OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     UNITS       "-dBc"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Microreflections, including in-channel response
 | 
						|
          as perceived on this interface, measured in dBc below
 | 
						|
          the signal level.
 | 
						|
          This object is not assumed to return an absolutely
 | 
						|
          accurate value, but it gives a rough indication
 | 
						|
 | 
						|
          of microreflections received on this interface.
 | 
						|
          It is up to the implementer to provide information
 | 
						|
          as accurately as possible."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 4-1 and 4-2"
 | 
						|
     ::= { docsIfSignalQualityEntry 6 }
 | 
						|
 | 
						|
docsIfSigQEqualizationData OBJECT-TYPE
 | 
						|
        SYNTAX      DocsEqualizerData
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "At the CM, this object returns the equalization data for
 | 
						|
             the downstream channel.
 | 
						|
 | 
						|
             At the CMTS, this object is not applicable and is not
 | 
						|
             instantiated.  Note that previous CMTS implementations
 | 
						|
             may instantiate this object in two ways:
 | 
						|
             - An equalization value indicating an equalization
 | 
						|
               average for the upstream channel.  Those values have
 | 
						|
               vendor-dependent interpretations.
 | 
						|
             - Return a zero-length OCTET STRING to indicate that
 | 
						|
               the value is unknown or if there is no equalization
 | 
						|
               data available or defined."
 | 
						|
        REFERENCE
 | 
						|
            "DOCSIS Radio Frequency Interface Specification,
 | 
						|
             Figure 6-23."
 | 
						|
        ::= { docsIfSignalQualityEntry 7 }
 | 
						|
 | 
						|
docsIfSigQExtUnerroreds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received on this channel without error.
 | 
						|
          This includes all codewords, whether or not they
 | 
						|
          were part of frames destined for this device.
 | 
						|
          This is the 64-bit version of docsIfSigQUnerroreds.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 6.2.4, and 6.3.6."
 | 
						|
     ::= { docsIfSignalQualityEntry 8 }
 | 
						|
 | 
						|
docsIfSigQExtCorrecteds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received on this channel with correctable
 | 
						|
          errors.  This includes all codewords, whether or not
 | 
						|
          they were part of frames destined for this device.
 | 
						|
          This is the 64-bit version of docsIfSigQCorrecteds.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 6.2.4, and 6.3.6."
 | 
						|
     ::= { docsIfSignalQualityEntry 9 }
 | 
						|
 | 
						|
docsIfSigQExtUncorrectables OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received on this channel with uncorrectable
 | 
						|
          errors.  This includes all codewords, whether or not
 | 
						|
          they were part of frames destined for this device.
 | 
						|
          This is the 64-bit version of docsIfSigQUncorrectables.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Sections 6.2.4, 6.3.6."
 | 
						|
     ::= { docsIfSignalQualityEntry 10 }
 | 
						|
 | 
						|
--
 | 
						|
-- DOCSIS Version of the device
 | 
						|
--
 | 
						|
 | 
						|
docsIfDocsisBaseCapability OBJECT-TYPE
 | 
						|
        SYNTAX      DocsisVersion
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Indication of the DOCSIS capability of the device."
 | 
						|
        REFERENCE
 | 
						|
            "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
             Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
             Annex G."
 | 
						|
        ::= { docsIfBaseObjects 5 }
 | 
						|
 | 
						|
--
 | 
						|
-- CABLE MODEM GROUP
 | 
						|
--
 | 
						|
 | 
						|
--
 | 
						|
-- The CM MAC Table
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmMacTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmMacEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes of each CM MAC interface,
 | 
						|
          extending the information available from ifEntry."
 | 
						|
     ::= { docsIfCmObjects 1 }
 | 
						|
 | 
						|
docsIfCmMacEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmMacEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "An entry containing objects describing attributes of
 | 
						|
          each MAC entry, extending the information in ifEntry.
 | 
						|
          An entry in this table exists for each ifEntry with an
 | 
						|
          ifType of docsCableMaclayer(127)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfCmMacTable 1 }
 | 
						|
 | 
						|
DocsIfCmMacEntry ::= SEQUENCE {
 | 
						|
         docsIfCmCmtsAddress           MacAddress,
 | 
						|
         docsIfCmCapabilities          BITS,
 | 
						|
         docsIfCmRangingRespTimeout    TimeTicks,
 | 
						|
         docsIfCmRangingTimeout        TimeInterval
 | 
						|
      }
 | 
						|
 | 
						|
docsIfCmCmtsAddress OBJECT-TYPE
 | 
						|
     SYNTAX      MacAddress
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Identifies the CMTS that is believed to control this MAC
 | 
						|
          domain.  At the CM, this will be the source address from
 | 
						|
          SYNC, MAP, and other MAC-layer messages.  If the CMTS is
 | 
						|
          unknown, returns 00-00-00-00-00-00."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.2.2."
 | 
						|
     ::= { docsIfCmMacEntry 1 }
 | 
						|
 | 
						|
docsIfCmCapabilities OBJECT-TYPE
 | 
						|
     SYNTAX      BITS {
 | 
						|
         atmCells(0),
 | 
						|
         concatenation(1)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Identifies the capabilities of the MAC implementation
 | 
						|
          at this interface.  Note that packet transmission is
 | 
						|
          always supported.  Therefore, there is no specific bit
 | 
						|
          required to explicitly indicate this capability.
 | 
						|
          Note that BITS objects are encoded most significant bit
 | 
						|
          first.  For example, if bit 1 is set, the value of this
 | 
						|
          object is the octet string '40'H."
 | 
						|
     ::= { docsIfCmMacEntry 2 }
 | 
						|
 | 
						|
docsIfCmRangingRespTimeout OBJECT-TYPE
 | 
						|
     SYNTAX      TimeTicks
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      obsolete
 | 
						|
     DESCRIPTION
 | 
						|
         "Waiting time for a Ranging Response packet.
 | 
						|
          This object has been obsoleted and replaced by
 | 
						|
          docsIfCmRangingTimeout to correct the typing to
 | 
						|
          TimeInterval."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.1.6."
 | 
						|
     DEFVAL { 20 }
 | 
						|
     ::= { docsIfCmMacEntry 3 }
 | 
						|
 | 
						|
docsIfCmRangingTimeout OBJECT-TYPE
 | 
						|
     SYNTAX      TimeInterval
 | 
						|
     UNITS       "HundredOfSeconds"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Waiting time for a Ranging Response packet.
 | 
						|
          This object MUST NOT persist at reinitialization
 | 
						|
          of the managed system."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.1.6, timer T3."
 | 
						|
     DEFVAL { 20 }
 | 
						|
     ::= { docsIfCmMacEntry 4 }
 | 
						|
 | 
						|
--
 | 
						|
-- CM status table.
 | 
						|
-- This table is implemented only at the CM.
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmStatusTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmStatusEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This table maintains a number of status objects
 | 
						|
          and counters for Cable Modems."
 | 
						|
     ::= { docsIfCmObjects 2 }
 | 
						|
 | 
						|
docsIfCmStatusEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmStatusEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "A set of status objects and counters for a single MAC
 | 
						|
          layer instance in Cable Modem.
 | 
						|
          An entry in this table exists for each ifEntry with an
 | 
						|
          ifType of docsCableMaclayer(127)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfCmStatusTable 1 }
 | 
						|
 | 
						|
DocsIfCmStatusEntry ::= SEQUENCE {
 | 
						|
         docsIfCmStatusValue               INTEGER,
 | 
						|
         docsIfCmStatusCode                OCTET STRING,
 | 
						|
         docsIfCmStatusTxPower             TenthdBmV,
 | 
						|
         docsIfCmStatusResets              Counter32,
 | 
						|
         docsIfCmStatusLostSyncs           Counter32,
 | 
						|
         docsIfCmStatusInvalidMaps         Counter32,
 | 
						|
         docsIfCmStatusInvalidUcds         Counter32,
 | 
						|
         docsIfCmStatusInvalidRangingResponses   Counter32,
 | 
						|
         docsIfCmStatusInvalidRegistrationResponses Counter32,
 | 
						|
         docsIfCmStatusT1Timeouts          Counter32,
 | 
						|
         docsIfCmStatusT2Timeouts          Counter32,
 | 
						|
         docsIfCmStatusT3Timeouts          Counter32,
 | 
						|
         docsIfCmStatusT4Timeouts          Counter32,
 | 
						|
         docsIfCmStatusRangingAborteds     Counter32,
 | 
						|
         docsIfCmStatusDocsisOperMode      DocsisQosVersion,
 | 
						|
         docsIfCmStatusModulationType      DocsisUpstreamType,
 | 
						|
         docsIfCmStatusEqualizationData    DocsEqualizerData,
 | 
						|
         docsIfCmStatusUCCs                Counter32,
 | 
						|
         docsIfCmStatusUCCFails            Counter32
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmStatusValue OBJECT-TYPE
 | 
						|
     SYNTAX      INTEGER {
 | 
						|
         other(1),
 | 
						|
         notReady(2),
 | 
						|
         notSynchronized(3),
 | 
						|
         phySynchronized(4),
 | 
						|
         usParametersAcquired(5),
 | 
						|
         rangingComplete(6),
 | 
						|
         ipComplete(7),
 | 
						|
         todEstablished(8),
 | 
						|
         securityEstablished(9),
 | 
						|
         paramTransferComplete(10),
 | 
						|
         registrationComplete(11),
 | 
						|
         operational(12),
 | 
						|
         accessDenied(13)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current Cable Modem connectivity state, as specified
 | 
						|
          in the RF Interface Specification.  Interpretations for
 | 
						|
          state values 1-12 are clearly outlined in the SP-RFI
 | 
						|
          reference given below.
 | 
						|
          The state value accessDenied(13) indicates the CMTS has
 | 
						|
          sent a Registration Aborted message to the CM.  The same
 | 
						|
          state is reported as accessDenied(7) by the CMTS object
 | 
						|
          docsIfCmtsCmStatusValue."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 11.2.
 | 
						|
          Data-Over-Cable Service Interface Specifications:
 | 
						|
 | 
						|
          Operations Support System Interface Specification
 | 
						|
          SP-OSSIv2.0-I09-050812, Section 6.3.4.2."
 | 
						|
     ::= { docsIfCmStatusEntry 1 }
 | 
						|
 | 
						|
docsIfCmStatusCode OBJECT-TYPE
 | 
						|
     SYNTAX      OCTET STRING (SIZE( 0 | 5 | 6 ))
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Status code for a Cable Modem as defined in the
 | 
						|
          OSSI Specification.  The status code consists
 | 
						|
          of a single character indicating error groups, followed
 | 
						|
          by a two- or three-digit number indicating the status
 | 
						|
          condition, followed by a decimal.
 | 
						|
          An example of a returned value could be 'T101.0'.
 | 
						|
          The zero-length OCTET STRING indicates no status code yet
 | 
						|
          registered."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications:
 | 
						|
          Operations Support System Interface Specification
 | 
						|
          SP-OSSIv2.0-I09-050812, Annex D."
 | 
						|
     ::= { docsIfCmStatusEntry 2 }
 | 
						|
 | 
						|
docsIfCmStatusTxPower OBJECT-TYPE
 | 
						|
     SYNTAX      TenthdBmV
 | 
						|
     UNITS       "TenthdBmV"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The operational transmit power for the attached upstream
 | 
						|
          channel."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.18."
 | 
						|
     ::= { docsIfCmStatusEntry 3 }
 | 
						|
 | 
						|
docsIfCmStatusResets OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "resets"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times the CM reset or initialized this
 | 
						|
          interface.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmStatusEntry 4 }
 | 
						|
 | 
						|
docsIfCmStatusLostSyncs OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times the CM lost synchronization with
 | 
						|
          the downstream channel.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.2."
 | 
						|
     ::= { docsIfCmStatusEntry 5 }
 | 
						|
 | 
						|
docsIfCmStatusInvalidMaps OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "maps"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times the CM received invalid MAP messages.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.4."
 | 
						|
     ::= { docsIfCmStatusEntry 6 }
 | 
						|
 | 
						|
docsIfCmStatusInvalidUcds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "messages"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times the CM received invalid UCD messages.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.3."
 | 
						|
     ::= { docsIfCmStatusEntry 7 }
 | 
						|
 | 
						|
docsIfCmStatusInvalidRangingResponses OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "messages"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times the CM received invalid ranging response
 | 
						|
          messages.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.6."
 | 
						|
     ::= { docsIfCmStatusEntry 8 }
 | 
						|
 | 
						|
docsIfCmStatusInvalidRegistrationResponses OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "messages"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times the CM received invalid registration
 | 
						|
          response messages.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.8."
 | 
						|
     ::= { docsIfCmStatusEntry 9 }
 | 
						|
 | 
						|
docsIfCmStatusT1Timeouts OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "timeouts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times counter T1 expired in the CM.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 9-2."
 | 
						|
     ::= { docsIfCmStatusEntry 10 }
 | 
						|
 | 
						|
docsIfCmStatusT2Timeouts OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "timeouts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times counter T2 expired in the CM.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 9-2."
 | 
						|
     ::= { docsIfCmStatusEntry 11 }
 | 
						|
 | 
						|
docsIfCmStatusT3Timeouts OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "timeouts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times counter T3 expired in the CM.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 9-2."
 | 
						|
     ::= { docsIfCmStatusEntry 12 }
 | 
						|
 | 
						|
docsIfCmStatusT4Timeouts OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "timeouts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times counter T4 expired in the CM.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 9-2."
 | 
						|
     ::= { docsIfCmStatusEntry 13 }
 | 
						|
 | 
						|
docsIfCmStatusRangingAborteds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "attempts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Number of times the ranging process was aborted
 | 
						|
          by the CMTS.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.3.3."
 | 
						|
     ::= { docsIfCmStatusEntry 14 }
 | 
						|
 | 
						|
docsIfCmStatusDocsisOperMode OBJECT-TYPE
 | 
						|
     SYNTAX      DocsisQosVersion
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
          "Indication of whether the device has registered using 1.0
 | 
						|
           Class of Service or 1.1 Quality of Service.
 | 
						|
           An unregistered CM SHOULD indicate 'docsis11' for a
 | 
						|
           docsIfDocsisBaseCapability value of DOCSIS 1.1/2.0.  An
 | 
						|
           unregistered CM SHOULD indicate 'docsis10'  for a
 | 
						|
           docsIfDocsisBaseCapability value of DOCSIS 1.0."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex G."
 | 
						|
     ::= { docsIfCmStatusEntry 15 }
 | 
						|
 | 
						|
docsIfCmStatusModulationType OBJECT-TYPE
 | 
						|
      SYNTAX      DocsisUpstreamType
 | 
						|
      MAX-ACCESS  read-only
 | 
						|
      STATUS      current
 | 
						|
      DESCRIPTION
 | 
						|
          "Indicates modulation type status currently used by the
 | 
						|
           CM.  Since this object specifically identifies PHY mode,
 | 
						|
           the shared upstream channel type is not permitted."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.1."
 | 
						|
      ::= { docsIfCmStatusEntry 16 }
 | 
						|
 | 
						|
docsIfCmStatusEqualizationData OBJECT-TYPE
 | 
						|
     SYNTAX      DocsEqualizerData
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Pre-equalization data for this CM after convolution with
 | 
						|
          data indicated in the RNG-RSP.  This data is valid when
 | 
						|
          docsIfUpChannelPreEqEnable is set to true."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 8-23."
 | 
						|
     ::= { docsIfCmStatusEntry 17 }
 | 
						|
 | 
						|
docsIfCmStatusUCCs OBJECT-TYPE
 | 
						|
     SYNTAX          Counter32
 | 
						|
     UNITS           "attempts"
 | 
						|
     MAX-ACCESS      read-only
 | 
						|
     STATUS          current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of successful Upstream Channel Change
 | 
						|
          transactions.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmStatusEntry 18 }
 | 
						|
 | 
						|
docsIfCmStatusUCCFails OBJECT-TYPE
 | 
						|
     SYNTAX          Counter32
 | 
						|
     UNITS           "attempts"
 | 
						|
     MAX-ACCESS      read-only
 | 
						|
     STATUS          current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of failed Upstream Channel Change
 | 
						|
          transactions.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmStatusEntry 19 }
 | 
						|
 | 
						|
--
 | 
						|
-- The Cable Modem Service Table
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmServiceTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmServiceEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes of each upstream service queue
 | 
						|
          on a CM."
 | 
						|
     ::= { docsIfCmObjects 3 }
 | 
						|
 | 
						|
docsIfCmServiceEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmServiceEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes of an upstream bandwidth service
 | 
						|
          queue.
 | 
						|
          An entry in this table exists for each Service ID.
 | 
						|
          The primary index is an ifIndex with an ifType of
 | 
						|
          docsCableMaclayer(127)."
 | 
						|
     INDEX { ifIndex, docsIfCmServiceId }
 | 
						|
     ::= { docsIfCmServiceTable 1 }
 | 
						|
 | 
						|
DocsIfCmServiceEntry ::= SEQUENCE {
 | 
						|
         docsIfCmServiceId               Integer32,
 | 
						|
         docsIfCmServiceQosProfile       Integer32,
 | 
						|
         docsIfCmServiceTxSlotsImmed     Counter32,
 | 
						|
         docsIfCmServiceTxSlotsDed       Counter32,
 | 
						|
         docsIfCmServiceTxRetries        Counter32,
 | 
						|
         docsIfCmServiceTxExceededs      Counter32,
 | 
						|
         docsIfCmServiceRqRetries        Counter32,
 | 
						|
         docsIfCmServiceRqExceededs      Counter32,
 | 
						|
         docsIfCmServiceExtTxSlotsImmed  Counter64,
 | 
						|
         docsIfCmServiceExtTxSlotsDed    Counter64
 | 
						|
 | 
						|
      }
 | 
						|
 | 
						|
docsIfCmServiceId OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..16383)
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Identifies a service queue for upstream bandwidth.  The
 | 
						|
          attributes of this service queue are shared between the
 | 
						|
          CM and the CMTS.  The CMTS allocates upstream bandwidth
 | 
						|
          to this service queue based on requests from the CM and
 | 
						|
          on the class of service associated with this queue."
 | 
						|
     ::= { docsIfCmServiceEntry 1 }
 | 
						|
 | 
						|
docsIfCmServiceQosProfile OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16383)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The index in docsIfQosProfileTable describing the quality
 | 
						|
          of service attributes associated with this particular
 | 
						|
          service.  If no associated entry in docsIfQosProfileTable
 | 
						|
          exists, this object returns a value of zero."
 | 
						|
     ::= { docsIfCmServiceEntry 2 }
 | 
						|
 | 
						|
docsIfCmServiceTxSlotsImmed OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of upstream mini-slots that have been used to
 | 
						|
          transmit data PDUs in immediate (contention) mode.  This
 | 
						|
          includes only those PDUs that are presumed to have
 | 
						|
          arrived at the head-end (i.e., those that were explicitly
 | 
						|
          acknowledged).  It does not include retransmission attempts
 | 
						|
          or mini-slots used by requests.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 3 }
 | 
						|
 | 
						|
docsIfCmServiceTxSlotsDed OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of upstream mini-slots that have been used to
 | 
						|
          transmit data PDUs in dedicated mode (i.e., as a result
 | 
						|
          of a unicast Data Grant).
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 4 }
 | 
						|
 | 
						|
docsIfCmServiceTxRetries OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "attempts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of attempts to transmit data PDUs containing
 | 
						|
          requests for acknowledgment that did not result in
 | 
						|
          acknowledgment.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 5 }
 | 
						|
 | 
						|
docsIfCmServiceTxExceededs OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "attempts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of data PDU transmission failures due to
 | 
						|
          excessive retries without acknowledgment.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 6 }
 | 
						|
 | 
						|
docsIfCmServiceRqRetries OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "attempts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of attempts to transmit bandwidth requests
 | 
						|
          that did not result in acknowledgment.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 7 }
 | 
						|
 | 
						|
docsIfCmServiceRqExceededs OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "attempts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of requests for bandwidth that failed due to
 | 
						|
          excessive retries without acknowledgment.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 8 }
 | 
						|
 | 
						|
docsIfCmServiceExtTxSlotsImmed OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of upstream mini-slots that have been used to
 | 
						|
          transmit data PDUs in immediate (contention) mode.  This
 | 
						|
          includes only those PDUs that are presumed to have
 | 
						|
          arrived at the head-end (i.e., those that were explicitly
 | 
						|
          acknowledged).  It does not include retransmission attempts
 | 
						|
          or mini-slots used by requests.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 9 }
 | 
						|
 | 
						|
docsIfCmServiceExtTxSlotsDed OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of upstream mini-slots that have been used to
 | 
						|
          transmit data PDUs in dedicated mode (i.e., as a result
 | 
						|
          of a unicast Data Grant).
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.4."
 | 
						|
     ::= { docsIfCmServiceEntry 10 }
 | 
						|
 | 
						|
--
 | 
						|
-- CMTS GROUP
 | 
						|
--
 | 
						|
 | 
						|
--
 | 
						|
-- The CMTS MAC Table
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmtsMacTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsMacEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes of each CMTS MAC interface,
 | 
						|
          extending the information available from ifEntry.
 | 
						|
          Mandatory for all CMTS devices."
 | 
						|
     ::= { docsIfCmtsObjects 1 }
 | 
						|
 | 
						|
docsIfCmtsMacEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsMacEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "An entry containing objects describing attributes of each
 | 
						|
          MAC entry, extending the information in ifEntry.
 | 
						|
          An entry in this table exists for each ifEntry with an
 | 
						|
          ifType of docsCableMaclayer(127)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfCmtsMacTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsMacEntry ::= SEQUENCE {
 | 
						|
         docsIfCmtsCapabilities            BITS,
 | 
						|
         docsIfCmtsSyncInterval            Integer32,
 | 
						|
         docsIfCmtsUcdInterval             Integer32,
 | 
						|
         docsIfCmtsMaxServiceIds           Integer32,
 | 
						|
         docsIfCmtsInsertionInterval       TimeTicks,   -- Obsolete
 | 
						|
         docsIfCmtsInvitedRangingAttempts  Integer32,
 | 
						|
         docsIfCmtsInsertInterval          TimeInterval,
 | 
						|
         docsIfCmtsMacStorageType          StorageType
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsCapabilities OBJECT-TYPE
 | 
						|
     SYNTAX      BITS {
 | 
						|
         atmCells(0),
 | 
						|
         concatenation(1)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Identifies the capabilities of the CMTS MAC
 | 
						|
          implementation at this interface.  Note that packet
 | 
						|
          transmission is always supported.  Therefore, there
 | 
						|
          is no specific bit required to explicitly indicate
 | 
						|
          this capability.
 | 
						|
          Note that BITS objects are encoded most significant bit
 | 
						|
          first.  For example, if bit 1 is set, the value of this
 | 
						|
          object is the octet string '40'H."
 | 
						|
     ::= { docsIfCmtsMacEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsSyncInterval OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..200)
 | 
						|
     UNITS       "Milliseconds"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The interval between CMTS transmission of successive SYNC
 | 
						|
          messages at this interface."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.3."
 | 
						|
     ::= { docsIfCmtsMacEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsUcdInterval OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..2000)
 | 
						|
     UNITS       "Milliseconds"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The interval between CMTS transmission of successive
 | 
						|
          Upstream Channel Descriptor messages for each upstream
 | 
						|
          channel at this interface."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.3"
 | 
						|
     ::= { docsIfCmtsMacEntry 3 }
 | 
						|
 | 
						|
docsIfCmtsMaxServiceIds OBJECT-TYPE
 | 
						|
     SYNTAX     Integer32 (1..16383)
 | 
						|
     UNITS      "SIDs"
 | 
						|
     MAX-ACCESS read-only
 | 
						|
     STATUS     current
 | 
						|
     DESCRIPTION
 | 
						|
         "The maximum number of service IDs that may be
 | 
						|
          simultaneously active."
 | 
						|
     ::= { docsIfCmtsMacEntry 4 }
 | 
						|
 | 
						|
docsIfCmtsInsertionInterval OBJECT-TYPE
 | 
						|
     SYNTAX      TimeTicks
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      obsolete
 | 
						|
     DESCRIPTION
 | 
						|
         "The amount of time to elapse between each broadcast
 | 
						|
          initial maintenance grant.  Broadcast initial maintenance
 | 
						|
          grants are used to allow new cable modems to join the
 | 
						|
          network.  Zero indicates that a vendor-specific algorithm
 | 
						|
          is used instead of a fixed time.  The maximum amount of
 | 
						|
 | 
						|
          time permitted by the specification is 2 seconds.
 | 
						|
          This object has been obsoleted and replaced by
 | 
						|
          docsIfCmtsInsertInterval to fix a SYNTAX typing problem."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex B."
 | 
						|
     ::= { docsIfCmtsMacEntry 5 }
 | 
						|
 | 
						|
docsIfCmtsInvitedRangingAttempts OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..1024)
 | 
						|
     UNITS      "attempts"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The maximum number of attempts to make on invitations
 | 
						|
          for ranging requests.  A value of zero means the system
 | 
						|
          SHOULD attempt to range forever."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 9.3.3 and Annex B."
 | 
						|
     ::= { docsIfCmtsMacEntry 6 }
 | 
						|
 | 
						|
docsIfCmtsInsertInterval OBJECT-TYPE
 | 
						|
     SYNTAX      TimeInterval
 | 
						|
     UNITS       "HundredOfSeconds"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The amount of time to elapse between each broadcast
 | 
						|
          initial maintenance grant.  Broadcast initial maintenance
 | 
						|
          grants are used to allow new cable modems to join the
 | 
						|
          network.  Zero indicates that a vendor-specific algorithm
 | 
						|
          is used instead of a fixed time.  The maximum amount of
 | 
						|
          time permitted by the specification is 2 seconds."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex B."
 | 
						|
     ::= { docsIfCmtsMacEntry 7 }
 | 
						|
 | 
						|
docsIfCmtsMacStorageType OBJECT-TYPE
 | 
						|
     SYNTAX       StorageType
 | 
						|
     MAX-ACCESS   read-only
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "The storage type for this conceptual row.
 | 
						|
 | 
						|
          Entries with this object set to permanent(4)
 | 
						|
          do not require write operations for read-write
 | 
						|
          objects."
 | 
						|
     ::= { docsIfCmtsMacEntry 8 }
 | 
						|
 | 
						|
--
 | 
						|
--
 | 
						|
-- CMTS status table.
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmtsStatusTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsStatusEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "For the MAC layer, this group maintains a number of
 | 
						|
          status objects and counters."
 | 
						|
     ::= { docsIfCmtsObjects 2 }
 | 
						|
 | 
						|
docsIfCmtsStatusEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsStatusEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
        "Status entry for a single MAC layer.
 | 
						|
          An entry in this table exists for each ifEntry with an
 | 
						|
          ifType of docsCableMaclayer(127)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfCmtsStatusTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsStatusEntry ::= SEQUENCE {
 | 
						|
         docsIfCmtsStatusInvalidRangeReqs        Counter32,
 | 
						|
         docsIfCmtsStatusRangingAborteds         Counter32,
 | 
						|
         docsIfCmtsStatusInvalidRegReqs          Counter32,
 | 
						|
         docsIfCmtsStatusFailedRegReqs           Counter32,
 | 
						|
         docsIfCmtsStatusInvalidDataReqs         Counter32,
 | 
						|
         docsIfCmtsStatusT5Timeouts              Counter32
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsStatusInvalidRangeReqs OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "messages"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object counts invalid RNG-REQ messages received on
 | 
						|
          this interface.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.5."
 | 
						|
     ::= { docsIfCmtsStatusEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsStatusRangingAborteds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "attempts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object counts ranging attempts that were explicitly
 | 
						|
          aborted by the CMTS.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.6."
 | 
						|
     ::= { docsIfCmtsStatusEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsStatusInvalidRegReqs OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "messages"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object counts invalid REG-REQ messages received on
 | 
						|
          this interface; that is, syntax, out of range parameters,
 | 
						|
          or erroneous requests.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.7."
 | 
						|
     ::= { docsIfCmtsStatusEntry 3 }
 | 
						|
 | 
						|
docsIfCmtsStatusFailedRegReqs OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "attempts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object counts failed registration attempts.  Included
 | 
						|
          are docsIfCmtsStatusInvalidRegReqs, authentication, and
 | 
						|
          class of service failures.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.3.7."
 | 
						|
     ::= { docsIfCmtsStatusEntry 4 }
 | 
						|
 | 
						|
docsIfCmtsStatusInvalidDataReqs OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "messages"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object counts invalid data request messages
 | 
						|
          received on this interface.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsStatusEntry 5 }
 | 
						|
 | 
						|
docsIfCmtsStatusT5Timeouts OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "timeouts"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object counts the number of times counter T5
 | 
						|
          expired on this interface.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 9-2."
 | 
						|
     ::= { docsIfCmtsStatusEntry 6 }
 | 
						|
 | 
						|
--
 | 
						|
-- CM status table (within CMTS).
 | 
						|
-- This table is implemented only at the CMTS.
 | 
						|
-- It contains per-CM status information available in the CMTS.
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmtsCmStatusTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsCmStatusEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "A set of objects in the CMTS, maintained for each
 | 
						|
          cable modem connected to this CMTS."
 | 
						|
     ::= { docsIfCmtsObjects 3 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsCmStatusEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Status information for a single cable modem.
 | 
						|
          An entry in this table exists for each cable modem
 | 
						|
          that is connected to the CMTS implementing this table."
 | 
						|
     INDEX { docsIfCmtsCmStatusIndex }
 | 
						|
     ::= { docsIfCmtsCmStatusTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsCmStatusEntry ::= SEQUENCE {
 | 
						|
         docsIfCmtsCmStatusIndex               Integer32,
 | 
						|
         docsIfCmtsCmStatusMacAddress          MacAddress,
 | 
						|
         docsIfCmtsCmStatusIpAddress        IpAddress, -- deprecated
 | 
						|
         docsIfCmtsCmStatusDownChannelIfIndex  InterfaceIndexOrZero,
 | 
						|
         docsIfCmtsCmStatusUpChannelIfIndex    InterfaceIndexOrZero,
 | 
						|
         docsIfCmtsCmStatusRxPower             TenthdBmV,
 | 
						|
         docsIfCmtsCmStatusTimingOffset        Unsigned32,
 | 
						|
         docsIfCmtsCmStatusEqualizationData    DocsEqualizerData,
 | 
						|
         docsIfCmtsCmStatusValue               INTEGER,
 | 
						|
         docsIfCmtsCmStatusUnerroreds          Counter32,
 | 
						|
         docsIfCmtsCmStatusCorrecteds          Counter32,
 | 
						|
         docsIfCmtsCmStatusUncorrectables      Counter32,
 | 
						|
         docsIfCmtsCmStatusSignalNoise         TenthdB,
 | 
						|
         docsIfCmtsCmStatusMicroreflections    Integer32,
 | 
						|
         docsIfCmtsCmStatusExtUnerroreds       Counter64,
 | 
						|
         docsIfCmtsCmStatusExtCorrecteds       Counter64,
 | 
						|
         docsIfCmtsCmStatusExtUncorrectables   Counter64,
 | 
						|
         docsIfCmtsCmStatusDocsisRegMode       DocsisQosVersion,
 | 
						|
         docsIfCmtsCmStatusModulationType      DocsisUpstreamType,
 | 
						|
         docsIfCmtsCmStatusInetAddressType     InetAddressType,
 | 
						|
         docsIfCmtsCmStatusInetAddress         InetAddress,
 | 
						|
         docsIfCmtsCmStatusValueLastUpdate     TimeStamp,
 | 
						|
         docsIfCmtsCmStatusHighResolutionTimingOffset Unsigned32
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsCmStatusIndex OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..2147483647)
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Index value to uniquely identify an entry in this table.
 | 
						|
          For an individual cable modem, this index value SHOULD
 | 
						|
          NOT change during CMTS uptime."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusMacAddress OBJECT-TYPE
 | 
						|
     SYNTAX      MacAddress
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "MAC address of the cable modem.  If the cable modem has
 | 
						|
          multiple MAC addresses, this is the MAC address associated
 | 
						|
          with the Cable interface."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 8.2.2."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusIpAddress OBJECT-TYPE
 | 
						|
     SYNTAX      IpAddress
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      deprecated
 | 
						|
     DESCRIPTION
 | 
						|
         "IP address of this cable modem.  If the cable modem has no
 | 
						|
          IP address assigned, or the IP address is unknown, this
 | 
						|
          object returns a value of 0.0.0.0.  If the cable modem has
 | 
						|
          multiple IP addresses, this object returns the IP address
 | 
						|
          associated with the Cable interface.
 | 
						|
          This object has been deprecated and replaced by
 | 
						|
          docsIfCmtsCmStatusInetAddressType and
 | 
						|
          docsIfCmtsCmStatusInetAddress, to enable IPv6 addressing
 | 
						|
          in the future."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 3 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusDownChannelIfIndex OBJECT-TYPE
 | 
						|
     SYNTAX      InterfaceIndexOrZero
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "IfIndex of the downstream channel that this CM is
 | 
						|
          connected to.  If the downstream channel is unknown, this
 | 
						|
          object returns a value of zero."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 4 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusUpChannelIfIndex OBJECT-TYPE
 | 
						|
     SYNTAX      InterfaceIndexOrZero
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
        "For DOCSIS 2.0, indicates the ifIndex of the logical
 | 
						|
         upstream channel (ifType 205) this CM is connected to.
 | 
						|
         For DOCSIS 1.x, indicates the ifIndex of the upstream
 | 
						|
          channel (ifType 129) this CM is connected to.
 | 
						|
          If the upstream channel is unknown, this object
 | 
						|
          returns a value of zero."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 5 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusRxPower OBJECT-TYPE
 | 
						|
     SYNTAX      TenthdBmV
 | 
						|
     UNITS       "ThenthdBmV"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The receive power as perceived for upstream data from
 | 
						|
          this cable modem.
 | 
						|
          If the receive power is unknown, this object returns
 | 
						|
          a value of zero."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.18."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 6 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusTimingOffset OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32 (0..4294967295)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "A measure of the current round trip time for this CM.
 | 
						|
          Used for timing of CM upstream transmissions to ensure
 | 
						|
          synchronized arrivals at the CMTS.  Units are in terms
 | 
						|
          of (6.25 microseconds/64).  Returns zero if the value
 | 
						|
          is unknown.
 | 
						|
          For channels requiring finer resolution, please refer to
 | 
						|
          object docsIfCmtsCmStatusHighResolutionTimingOffset."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.17."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 7 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusEqualizationData OBJECT-TYPE
 | 
						|
     SYNTAX      DocsEqualizerData
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Equalization data for this CM, as measured by the CMTS.
 | 
						|
          Returns the zero-length OCTET STRING if the value is
 | 
						|
          unknown or if there is no equalization data available
 | 
						|
          or defined."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Figure 8-23."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 8 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusValue OBJECT-TYPE
 | 
						|
     SYNTAX      INTEGER {
 | 
						|
         other(1),
 | 
						|
         ranging(2),
 | 
						|
         rangingAborted(3),
 | 
						|
         rangingComplete(4),
 | 
						|
         ipComplete(5),
 | 
						|
         registrationComplete(6),
 | 
						|
         accessDenied(7),
 | 
						|
         operational(8),
 | 
						|
         -- value 8 should not be used
 | 
						|
         registeredBPIInitializing(9)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current cable modem connectivity state, as specified
 | 
						|
          in the RF Interface Specification.  Returned status
 | 
						|
          information is the CM status, as assumed by the CMTS,
 | 
						|
          and indicates the following events:
 | 
						|
          other(1)
 | 
						|
             Any state other than below.
 | 
						|
          ranging(2)
 | 
						|
             The CMTS has received an Initial Ranging Request
 | 
						|
             message from the CM, and the ranging process is not
 | 
						|
             yet complete.
 | 
						|
          rangingAborted(3)
 | 
						|
             The CMTS has sent a Ranging Abort message to the CM.
 | 
						|
 | 
						|
          rangingComplete(4)
 | 
						|
             The CMTS has sent a Ranging Complete message to the CM.
 | 
						|
          ipComplete(5)
 | 
						|
             The CMTS has received a DHCP reply message and
 | 
						|
             forwarded it to the CM.
 | 
						|
          registrationComplete(6)
 | 
						|
             The CMTS has sent a Registration Response message to
 | 
						|
             the CM.
 | 
						|
          accessDenied(7)
 | 
						|
             The CMTS has sent a Registration Aborted message
 | 
						|
             to the CM.
 | 
						|
          operational(8)
 | 
						|
             Value 8 is considered reserved and should not be defined
 | 
						|
             in future revisions of this MIB module to avoid conflict
 | 
						|
             with documented implementations that support value 8 to
 | 
						|
             indicate operational state after completing the BPI
 | 
						|
             initialization process.
 | 
						|
          registeredBPIInitializing(9)
 | 
						|
             Baseline Privacy (BPI) is enabled and the CMTS is in the
 | 
						|
             process of completing BPI initialization.  This state
 | 
						|
             MAY last for a significant length of time if failures
 | 
						|
             occur during the initialization process.  After
 | 
						|
             completion of BPI initialization, the CMTS will report
 | 
						|
             registrationComplete(6).
 | 
						|
          The CMTS only needs to report states it is able to
 | 
						|
          detect."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 11.2."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 9 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusUnerroreds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received without error from this cable modem.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.4."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 10 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusCorrecteds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received with correctable errors from this
 | 
						|
          cable modem.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.4."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 11 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusUncorrectables OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received with uncorrectable errors from this
 | 
						|
          cable modem.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.4."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 12 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusSignalNoise OBJECT-TYPE
 | 
						|
     SYNTAX      TenthdB
 | 
						|
     UNITS       "TenthdB"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Signal/Noise ratio as perceived for upstream data from
 | 
						|
          this cable modem.
 | 
						|
          If the Signal/Noise is unknown, this object returns
 | 
						|
          a value of zero."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 4-1 and 4-2."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 13 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusMicroreflections OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     UNITS       "-dBc"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Total microreflections, including in-channel response
 | 
						|
          as perceived on this interface, measured in dBc below
 | 
						|
          the signal level.
 | 
						|
          This object is not assumed to return an absolutely
 | 
						|
          accurate value, but it gives a rough indication
 | 
						|
          of microreflections received on this interface.
 | 
						|
          It is up to the implementer to provide information
 | 
						|
          as accurately as possible.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 4-1 and 4-2"
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 14 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusExtUnerroreds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received without error from this cable modem.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.5."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 15 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusExtCorrecteds OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received with correctable errors from this
 | 
						|
          cable modem.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.5."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 16 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusExtUncorrectables OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "codewords"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Codewords received with uncorrectable errors from this
 | 
						|
          cable modem.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.5."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 17 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusDocsisRegMode OBJECT-TYPE
 | 
						|
        SYNTAX      DocsisQosVersion
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Indication of whether the CM has registered using 1.0
 | 
						|
             Class of Service or 1.1 Quality of Service."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Annex G."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 18 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusModulationType OBJECT-TYPE
 | 
						|
      SYNTAX      DocsisUpstreamType
 | 
						|
      MAX-ACCESS  read-only
 | 
						|
      STATUS      current
 | 
						|
      DESCRIPTION
 | 
						|
          "Indicates modulation type currently used by the CM.  Since
 | 
						|
           this object specifically identifies PHY mode, the shared
 | 
						|
           type is not permitted.  If the upstream channel is
 | 
						|
           unknown, this object returns a value of zero."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 8-19."
 | 
						|
      ::= { docsIfCmtsCmStatusEntry 19 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusInetAddressType OBJECT-TYPE
 | 
						|
        SYNTAX      InetAddressType
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "The type of internet address of
 | 
						|
             docsIfCmtsCmStatusInetAddress.  If the cable modem
 | 
						|
             internet address is unassigned or unknown, then the
 | 
						|
             value of this object is unknown(0)."
 | 
						|
        ::= { docsIfCmtsCmStatusEntry 20 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusInetAddress OBJECT-TYPE
 | 
						|
        SYNTAX      InetAddress
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Internet address of this cable modem.  If the Cable
 | 
						|
             Modem has no Internet address assigned, or the Internet
 | 
						|
             address is unknown, the value of this object is the
 | 
						|
             zero-length OCTET STRING.  If the cable modem has
 | 
						|
             multiple Internet addresses, this object returns the
 | 
						|
             Internet address associated with the Cable
 | 
						|
             (i.e., RF MAC) interface."
 | 
						|
        ::= { docsIfCmtsCmStatusEntry 21 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusValueLastUpdate OBJECT-TYPE
 | 
						|
        SYNTAX      TimeStamp
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "The value of sysUpTime when docsIfCmtsCmStatusValue
 | 
						|
             was last updated."
 | 
						|
        ::= { docsIfCmtsCmStatusEntry 22 }
 | 
						|
 | 
						|
docsIfCmtsCmStatusHighResolutionTimingOffset OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32 (0..4294967295)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "A measure of the current round trip time for this CM.
 | 
						|
          Used for timing of CM upstream transmissions to ensure
 | 
						|
          synchronized arrivals at the CMTS.  Units are in terms
 | 
						|
          of (6.25 microseconds/(64*256)).  Returns zero if the value
 | 
						|
          is unknown.
 | 
						|
          This is the high resolution version of object
 | 
						|
          docsIfCmtsCmStatusTimingOffset, for channels requiring
 | 
						|
          finer resolution."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Section 6.2.17."
 | 
						|
     ::= { docsIfCmtsCmStatusEntry 23 }
 | 
						|
 | 
						|
--
 | 
						|
-- The CMTS Service Table.
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmtsServiceTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsServiceEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes of upstream service queues
 | 
						|
          in a Cable Modem Termination System."
 | 
						|
     ::= { docsIfCmtsObjects 4 }
 | 
						|
 | 
						|
docsIfCmtsServiceEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsServiceEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the attributes of a single upstream bandwidth
 | 
						|
          service queue.
 | 
						|
          Entries in this table exist for each ifEntry with an
 | 
						|
          ifType of docsCableMaclayer(127), and for each service
 | 
						|
          queue (Service ID) within this MAC layer.
 | 
						|
          Entries in this table are created with the creation of
 | 
						|
          individual Service IDs by the MAC layer and removed
 | 
						|
          when a Service ID is removed."
 | 
						|
     INDEX { ifIndex, docsIfCmtsServiceId }
 | 
						|
     ::= { docsIfCmtsServiceTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsServiceEntry ::= SEQUENCE {
 | 
						|
 | 
						|
         docsIfCmtsServiceId               Integer32,
 | 
						|
         docsIfCmtsServiceCmStatusIndex    Integer32,  -- deprecated
 | 
						|
         docsIfCmtsServiceAdminStatus      INTEGER,
 | 
						|
         docsIfCmtsServiceQosProfile       Integer32,
 | 
						|
         docsIfCmtsServiceCreateTime       TimeStamp,
 | 
						|
         docsIfCmtsServiceInOctets         Counter32,
 | 
						|
         docsIfCmtsServiceInPackets        Counter32,
 | 
						|
         docsIfCmtsServiceNewCmStatusIndex Integer32
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsServiceId OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..16383)
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Identifies a service queue for upstream bandwidth.  The
 | 
						|
          attributes of this service queue are shared between the
 | 
						|
          Cable Modem and the Cable Modem Termination System.
 | 
						|
          The CMTS allocates upstream bandwidth to this service
 | 
						|
          queue based on requests from the CM and on the class of
 | 
						|
          service associated with this queue."
 | 
						|
     ::= { docsIfCmtsServiceEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsServiceCmStatusIndex OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..65535)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      deprecated
 | 
						|
     DESCRIPTION
 | 
						|
         "Pointer to an entry in docsIfCmtsCmStatusTable identifying
 | 
						|
          the cable modem using this Service Queue.  If multiple
 | 
						|
          cable modems are using this Service Queue, the value of
 | 
						|
          this object is zero.
 | 
						|
          This object has been deprecated and replaced by
 | 
						|
          docsIfCmtsServiceNewCmStatusIndex, to fix a mismatch
 | 
						|
          of the value range with respect to docsIfCmtsCmStatusIndex
 | 
						|
          (1..2147483647)."
 | 
						|
     ::= { docsIfCmtsServiceEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsServiceAdminStatus OBJECT-TYPE
 | 
						|
     SYNTAX      INTEGER {
 | 
						|
         enabled(1),
 | 
						|
         disabled(2),
 | 
						|
         destroyed(3) }
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Allows a service class for a particular modem to be
 | 
						|
          suppressed, (re-)enabled, or deleted altogether."
 | 
						|
     ::= { docsIfCmtsServiceEntry 3 }
 | 
						|
 | 
						|
docsIfCmtsServiceQosProfile OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16383)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The index in docsIfQosProfileTable describing the quality
 | 
						|
          of service attributes associated with this particular
 | 
						|
          service.  If no associated docsIfQosProfileTable entry
 | 
						|
          exists, this object returns a value of zero."
 | 
						|
     ::= { docsIfCmtsServiceEntry 4 }
 | 
						|
 | 
						|
docsIfCmtsServiceCreateTime OBJECT-TYPE
 | 
						|
     SYNTAX      TimeStamp
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The value of sysUpTime when this entry was created."
 | 
						|
     ::= { docsIfCmtsServiceEntry 5 }
 | 
						|
 | 
						|
docsIfCmtsServiceInOctets OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "Bytes"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The cumulative number of Packet Data octets received
 | 
						|
          on this Service ID.  The count does not include the
 | 
						|
          size of the Cable MAC header.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsServiceEntry 6 }
 | 
						|
 | 
						|
docsIfCmtsServiceInPackets OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "packets"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The cumulative number of Packet Data packets received
 | 
						|
          on this Service ID.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsServiceEntry 7 }
 | 
						|
 | 
						|
docsIfCmtsServiceNewCmStatusIndex OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..2147483647)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Pointer (via docsIfCmtsCmStatusIndex) to an entry in
 | 
						|
          docsIfCmtsCmStatusTable identifying the cable modem
 | 
						|
          using this Service Queue.  If multiple cable modems are
 | 
						|
          using this Service Queue, the value of this object is
 | 
						|
          zero."
 | 
						|
     ::= { docsIfCmtsServiceEntry 8 }
 | 
						|
 | 
						|
--
 | 
						|
-- The following table provides upstream channel modulation profiles.
 | 
						|
-- Entries in this table can be
 | 
						|
-- re-used by one or more upstream channels.  An upstream channel
 | 
						|
-- will have a modulation profile for each value of
 | 
						|
-- docsIfModIntervalUsageCode.
 | 
						|
--
 | 
						|
 | 
						|
docsIfCmtsModulationTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsModulationEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes a modulation profile associated with one or more
 | 
						|
          upstream channels."
 | 
						|
     ::= { docsIfCmtsObjects 5 }
 | 
						|
 | 
						|
docsIfCmtsModulationEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsModulationEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes a modulation profile for an Interval Usage Code
 | 
						|
          for one or more upstream channels.
 | 
						|
          Entries in this table are created by the operator.
 | 
						|
 | 
						|
          Initial default entries MAY be created at system
 | 
						|
          initialization time, which could report a value of
 | 
						|
          'permanent' or 'readOnly' for docsIfCmtsModStorageType.
 | 
						|
          A CMTS MAY reject the creation of additional Interval
 | 
						|
          Usage Codes for a modulation profile being defined at
 | 
						|
          Initialization time.
 | 
						|
          No individual objects have to be specified in order
 | 
						|
          to create an entry in this table.
 | 
						|
 | 
						|
          Note that some objects do not have DEFVAL clauses
 | 
						|
          but do have calculated defaults and need not be specified
 | 
						|
          during row creation."
 | 
						|
      INDEX { docsIfCmtsModIndex, docsIfCmtsModIntervalUsageCode}
 | 
						|
     ::= { docsIfCmtsModulationTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsModulationEntry ::= SEQUENCE {
 | 
						|
         docsIfCmtsModIndex                    Integer32,
 | 
						|
         docsIfCmtsModIntervalUsageCode        INTEGER,
 | 
						|
         docsIfCmtsModControl                  RowStatus,
 | 
						|
         docsIfCmtsModType                     INTEGER,
 | 
						|
         docsIfCmtsModPreambleLen              Integer32,
 | 
						|
         docsIfCmtsModDifferentialEncoding     TruthValue,
 | 
						|
         docsIfCmtsModFECErrorCorrection       Integer32,
 | 
						|
         docsIfCmtsModFECCodewordLength        Integer32,
 | 
						|
         docsIfCmtsModScramblerSeed            Integer32,
 | 
						|
         docsIfCmtsModMaxBurstSize             Integer32,
 | 
						|
         docsIfCmtsModGuardTimeSize            Unsigned32,
 | 
						|
         docsIfCmtsModLastCodewordShortened    TruthValue,
 | 
						|
         docsIfCmtsModScrambler                TruthValue,
 | 
						|
         docsIfCmtsModByteInterleaverDepth     Unsigned32,
 | 
						|
         docsIfCmtsModByteInterleaverBlockSize Unsigned32,
 | 
						|
         docsIfCmtsModPreambleType             INTEGER,
 | 
						|
         docsIfCmtsModTcmErrorCorrectionOn     TruthValue,
 | 
						|
         docsIfCmtsModScdmaInterleaverStepSize Unsigned32,
 | 
						|
         docsIfCmtsModScdmaSpreaderEnable      TruthValue,
 | 
						|
         docsIfCmtsModScdmaSubframeCodes       Unsigned32,
 | 
						|
         docsIfCmtsModChannelType              DocsisUpstreamType,
 | 
						|
         docsIfCmtsModStorageType              StorageType
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsModIndex OBJECT-TYPE
 | 
						|
     SYNTAX       Integer32 (1..2147483647)
 | 
						|
     MAX-ACCESS   not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
          "An index into the Channel Modulation table representing
 | 
						|
           a group of Interval Usage Codes, all associated with the
 | 
						|
           same channel."
 | 
						|
     ::= { docsIfCmtsModulationEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsModIntervalUsageCode OBJECT-TYPE
 | 
						|
     SYNTAX       INTEGER {
 | 
						|
         request(1),
 | 
						|
         requestData(2),
 | 
						|
         initialRanging(3),
 | 
						|
         periodicRanging(4),
 | 
						|
         shortData(5),
 | 
						|
         longData(6),
 | 
						|
         advPhyShortData(9),
 | 
						|
         advPhyLongData(10),
 | 
						|
         ugs(11)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "An index into the Channel Modulation table that, when
 | 
						|
          grouped with other Interval Usage Codes, fully
 | 
						|
          instantiates all modulation sets for a given upstream
 | 
						|
          channel."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 8-20."
 | 
						|
     ::= { docsIfCmtsModulationEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsModControl OBJECT-TYPE
 | 
						|
     SYNTAX      RowStatus
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Controls and reflects the status of rows in this table.
 | 
						|
          There is no restriction on the changing of values in this
 | 
						|
          table while their associated rows are active, with the
 | 
						|
          exception of:
 | 
						|
 | 
						|
          1. If a modulation profile is being referenced by one
 | 
						|
             or more upstream channels, an attempt to set the value
 | 
						|
             of docsIfCmtsModChannelType returns an
 | 
						|
             'inconsistentValue' error.
 | 
						|
 | 
						|
          2. If a modulation profile is being referenced by one
 | 
						|
             or more upstream channels, an attempt to set
 | 
						|
             docsIfCmtsModControl to destroy(6) or notInService(2)
 | 
						|
             returns an 'inconsistentValue' error."
 | 
						|
     ::= { docsIfCmtsModulationEntry 3 }
 | 
						|
 | 
						|
docsIfCmtsModType OBJECT-TYPE
 | 
						|
     SYNTAX      INTEGER {
 | 
						|
         other(1),
 | 
						|
         qpsk(2),
 | 
						|
         qam16(3),
 | 
						|
         qam8(4),
 | 
						|
         qam32(5),
 | 
						|
         qam64(6),
 | 
						|
         qam128(7)
 | 
						|
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The modulation type used on this channel.  Returns
 | 
						|
          other(1) if the modulation type is not
 | 
						|
          qpsk, qam16, qam8, qam32, qam64, or qam128.
 | 
						|
          Type qam128 is used for SCDMA channels only.
 | 
						|
          See the reference for the modulation profiles
 | 
						|
          implied by different modulation types."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { qpsk }
 | 
						|
     ::= { docsIfCmtsModulationEntry 4 }
 | 
						|
 | 
						|
docsIfCmtsModPreambleLen OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..1536)
 | 
						|
     UNITS       "bits"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The preamble length for this modulation profile in bits.
 | 
						|
          Default value is the minimum needed by the implementation
 | 
						|
          at the CMTS for the given modulation profile."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     ::= { docsIfCmtsModulationEntry 5 }
 | 
						|
 | 
						|
docsIfCmtsModDifferentialEncoding OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Specifies whether or not differential encoding is used
 | 
						|
          on this channel."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { false }
 | 
						|
     ::= { docsIfCmtsModulationEntry 6 }
 | 
						|
 | 
						|
docsIfCmtsModFECErrorCorrection OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..16)
 | 
						|
     UNITS       "Bytes"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of correctable errored bytes (t) used in
 | 
						|
          forward error correction code.  The value of 0 indicates
 | 
						|
          that no correction is employed.  The number of check bytes
 | 
						|
          appended will be twice this value."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 7 }
 | 
						|
 | 
						|
docsIfCmtsModFECCodewordLength OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..255)
 | 
						|
     UNITS       "Bytes"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of data bytes (k) in the forward error
 | 
						|
          correction codeword.
 | 
						|
          This object is not used if docsIfCmtsModFECErrorCorrection
 | 
						|
          is zero."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { 32 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 8 }
 | 
						|
 | 
						|
docsIfCmtsModScramblerSeed OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..32767)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The 15-bit seed value for the scrambler polynomial."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 8-19."
 | 
						|
     DEFVAL { 0 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 9 }
 | 
						|
 | 
						|
docsIfCmtsModMaxBurstSize OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The maximum number of mini-slots that can be transmitted
 | 
						|
          during this channel's burst time.  Returns zero if the
 | 
						|
          burst length is bounded by the allocation MAP rather than
 | 
						|
          by this profile.
 | 
						|
          Default value is 0, except for shortData, where it is 8."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 8-19."
 | 
						|
     ::= { docsIfCmtsModulationEntry 10 }
 | 
						|
 | 
						|
docsIfCmtsModGuardTimeSize OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     UNITS       "Symbol-times"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The number of symbol-times that MUST follow the end of
 | 
						|
          this channel's burst.  Default value is the minimum time
 | 
						|
          needed by the implementation for this modulation profile."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     ::= { docsIfCmtsModulationEntry 11 }
 | 
						|
 | 
						|
docsIfCmtsModLastCodewordShortened OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Indicates whether the last FEC codeword is truncated."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { true }
 | 
						|
     ::= { docsIfCmtsModulationEntry 12 }
 | 
						|
 | 
						|
docsIfCmtsModScrambler OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Indicates whether the scrambler is employed."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { false }
 | 
						|
     ::= { docsIfCmtsModulationEntry 13 }
 | 
						|
 | 
						|
docsIfCmtsModByteInterleaverDepth OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "ATDMA Byte Interleaver Depth (Ir).  This object returns 1
 | 
						|
          for non-ATDMA profiles."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { 1 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 14 }
 | 
						|
 | 
						|
docsIfCmtsModByteInterleaverBlockSize OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "ATDMA Byte Interleaver Block size (Br).  This object
 | 
						|
          returns zero for non-ATDMA profiles "
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { 18 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 15 }
 | 
						|
 | 
						|
docsIfCmtsModPreambleType OBJECT-TYPE
 | 
						|
     SYNTAX       INTEGER {
 | 
						|
         unknown(0),
 | 
						|
         qpsk0(1),
 | 
						|
         qpsk1(2)
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Preamble type for DOCSIS 2.0 bursts.  The value
 | 
						|
          'unknown(0)' represents a row entry consisting only of
 | 
						|
          DOCSIS 1.x bursts"
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { qpsk0 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 16 }
 | 
						|
 | 
						|
docsIfCmtsModTcmErrorCorrectionOn OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Trellis Code Modulation (TCM) On/Off.  This value returns
 | 
						|
          false for non-S-CDMA profiles."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { false }
 | 
						|
     ::= { docsIfCmtsModulationEntry 17 }
 | 
						|
 | 
						|
docsIfCmtsModScdmaInterleaverStepSize OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32 (0 | 1..32)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         " S-CDMA Interleaver step size.  This value returns zero
 | 
						|
           for non-S-CDMA profiles."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     DEFVAL { 1 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 18 }
 | 
						|
 | 
						|
docsIfCmtsModScdmaSpreaderEnable OBJECT-TYPE
 | 
						|
     SYNTAX      TruthValue
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         " S-CDMA spreader.  This value returns false for non-S-CDMA
 | 
						|
           profiles.  Default value for IUC 3 and 4 is OFF; for
 | 
						|
           all other IUCs it is ON."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Tables 6-7, and 8-19."
 | 
						|
     ::= { docsIfCmtsModulationEntry 19 }
 | 
						|
 | 
						|
docsIfCmtsModScdmaSubframeCodes OBJECT-TYPE
 | 
						|
     SYNTAX      Unsigned32 (0 | 1..128)
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         " S-CDMA sub-frame size.  This value returns zero
 | 
						|
           for non-S-CDMA profiles."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 6-7, and 8-19."
 | 
						|
     DEFVAL { 1 }
 | 
						|
     ::= { docsIfCmtsModulationEntry 20 }
 | 
						|
 | 
						|
docsIfCmtsModChannelType OBJECT-TYPE
 | 
						|
     SYNTAX      DocsisUpstreamType
 | 
						|
     MAX-ACCESS  read-create
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Describes the modulation channel type for this modulation
 | 
						|
          entry.
 | 
						|
          All the active entries in a modulation profile (that is all
 | 
						|
          active entries that share a common docsIfCmtsModIndex)
 | 
						|
          MUST have the same value of docsIfCmtsModChannelType."
 | 
						|
     REFERENCE
 | 
						|
         "Data-Over-Cable Service Interface Specifications: Radio
 | 
						|
          Frequency Interface Specification SP-RFIv2.0-I10-051209,
 | 
						|
          Table 8-19."
 | 
						|
     DEFVAL { tdma }
 | 
						|
     ::= { docsIfCmtsModulationEntry 21 }
 | 
						|
 | 
						|
docsIfCmtsModStorageType OBJECT-TYPE
 | 
						|
     SYNTAX       StorageType
 | 
						|
     MAX-ACCESS   read-only
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "The storage type for this conceptual row.
 | 
						|
          Entries with this object set to permanent(4)
 | 
						|
          do not require write operations for read-write
 | 
						|
          objects."
 | 
						|
     DEFVAL      { nonVolatile }
 | 
						|
 ::= { docsIfCmtsModulationEntry 22 }
 | 
						|
 | 
						|
docsIfCmtsQosProfilePermissions OBJECT-TYPE
 | 
						|
     SYNTAX      BITS {
 | 
						|
         createByManagement(0),
 | 
						|
         updateByManagement(1),
 | 
						|
         createByModems(2)
 | 
						|
 | 
						|
     }
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This object specifies permitted methods of creating
 | 
						|
          entries in docsIfQosProfileTable.
 | 
						|
          createByManagement(0) is set if entries can be created
 | 
						|
          using SNMP.  updateByManagement(1) is set if updating
 | 
						|
          entries using SNMP is permitted.  createByModems(2)
 | 
						|
          is set if entries can be created based on information
 | 
						|
          in REG-REQ MAC messages received from cable modems.
 | 
						|
          Information in this object is only applicable if
 | 
						|
          docsIfQosProfileTable is implemented as read-create.
 | 
						|
          Otherwise, this object is implemented as read-only
 | 
						|
          and returns createByModems(2).
 | 
						|
          Either createByManagement(0) or updateByManagement(1)
 | 
						|
          MUST be set when writing to this object.
 | 
						|
          Note that BITS objects are encoded most significant bit
 | 
						|
          first.  For example, if bit 2 is set, the value of this
 | 
						|
          object is the octet string '20'H."
 | 
						|
     ::= { docsIfCmtsObjects 6 }
 | 
						|
 | 
						|
docsIfCmtsMacToCmTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsMacToCmEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This is a table to provide a quick access index into the
 | 
						|
          docsIfCmtsCmStatusTable.  There is exactly one row in this
 | 
						|
          table for each row in the docsIfCmtsCmStatusTable.  In
 | 
						|
          general, the management station SHOULD use this table only
 | 
						|
          to get a pointer into the docsIfCmtsCmStatusTable (which
 | 
						|
          corresponds to the CM's RF interface MAC address) and
 | 
						|
          SHOULD not iterate (e.g., GetNext through) this table."
 | 
						|
     ::= { docsIfCmtsObjects 7 }
 | 
						|
 | 
						|
docsIfCmtsMacToCmEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsMacToCmEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "A row in the docsIfCmtsMacToCmTable.
 | 
						|
          An entry in this table exists for each cable modem
 | 
						|
          that is connected to the CMTS implementing this table."
 | 
						|
     INDEX   { docsIfCmtsCmMac }
 | 
						|
     ::= {docsIfCmtsMacToCmTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsMacToCmEntry ::= SEQUENCE {
 | 
						|
 | 
						|
             docsIfCmtsCmMac     MacAddress,
 | 
						|
             docsIfCmtsCmPtr     Integer32
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsCmMac OBJECT-TYPE
 | 
						|
     SYNTAX      MacAddress
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The RF side MAC address for the referenced CM (e.g., the
 | 
						|
          interface on the CM that has docsCableMacLayer(127) as
 | 
						|
          its ifType)."
 | 
						|
     ::= { docsIfCmtsMacToCmEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsCmPtr OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (1..2147483647)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "An row index into docsIfCmtsCmStatusTable.  When queried
 | 
						|
          with the correct instance value (e.g., a CM's MAC address),
 | 
						|
          returns the index in docsIfCmtsCmStatusTable that
 | 
						|
          represents that CM."
 | 
						|
     ::= { docsIfCmtsMacToCmEntry 2 }
 | 
						|
 | 
						|
-- The following independent object and associated table provide
 | 
						|
-- operators with a mechanism to evaluate the load/utilization of
 | 
						|
-- both upstream and downstream physical channels.  This information
 | 
						|
-- may be used for capacity planning and incident analysis and may
 | 
						|
-- be particularly helpful in provisioning of high value QOS.
 | 
						|
--
 | 
						|
-- Utilization is expressed as an index representing the calculated
 | 
						|
-- percentage utilization of the upstream or downstream channel in
 | 
						|
-- the most recent sampling interval (i.e., utilization interval).
 | 
						|
-- Refer to the DESCRIPTION field of the
 | 
						|
-- docsIfCmtsChannelUtUtilization object for definitions and
 | 
						|
-- calculation details.
 | 
						|
 | 
						|
docsIfCmtsChannelUtilizationInterval OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..86400)
 | 
						|
     UNITS       "seconds"
 | 
						|
     MAX-ACCESS  read-write
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The time interval in seconds over which the channel
 | 
						|
          utilization index is calculated.  All upstream/downstream
 | 
						|
          channels use the same
 | 
						|
          docsIfCmtsChannelUtilizationInterval.
 | 
						|
 | 
						|
          Setting a value of zero disables utilization reporting.
 | 
						|
          A channel utilization index is calculated over a fixed
 | 
						|
          window applying to the most recent
 | 
						|
          docsIfCmtsChannelUtilizationInterval.  It would therefore
 | 
						|
          be prudent to use a relatively short
 | 
						|
          docsIfCmtsChannelUtilizationInterval.
 | 
						|
          It is a vendor decision whether to reset the timer when
 | 
						|
          docsIfCmtsChannelUtilizationInterval is changed during a
 | 
						|
          utilization sampling period."
 | 
						|
     ::= { docsIfCmtsObjects 8 }
 | 
						|
 | 
						|
docsIfCmtsChannelUtilizationTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsChannelUtilizationEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Reports utilization statistics for attached upstream and
 | 
						|
          downstream physical channels."
 | 
						|
     ::= { docsIfCmtsObjects 9 }
 | 
						|
 | 
						|
docsIfCmtsChannelUtilizationEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsChannelUtilizationEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Utilization statistics for a single upstream or downstream
 | 
						|
          physical channel.  An entry exists in this table for each
 | 
						|
          ifEntry with an ifType equal to
 | 
						|
          docsCableDownstream (128)
 | 
						|
          or docsCableUpstream (129)."
 | 
						|
     INDEX  { ifIndex, docsIfCmtsChannelUtIfType,
 | 
						|
          docsIfCmtsChannelUtId }
 | 
						|
     ::= { docsIfCmtsChannelUtilizationTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsChannelUtilizationEntry ::= SEQUENCE {
 | 
						|
         docsIfCmtsChannelUtIfType         IANAifType,
 | 
						|
         docsIfCmtsChannelUtId             Integer32,
 | 
						|
         docsIfCmtsChannelUtUtilization    Integer32
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsChannelUtIfType OBJECT-TYPE
 | 
						|
     SYNTAX       IANAifType
 | 
						|
     MAX-ACCESS   not-accessible
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "The secondary index into this table.  Indicates the IANA
 | 
						|
          interface type associated with this physical channel.
 | 
						|
          Only docsCableDownstream (128) and
 | 
						|
 | 
						|
          docsCableUpstream (129) are valid."
 | 
						|
     ::= { docsIfCmtsChannelUtilizationEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsChannelUtId OBJECT-TYPE
 | 
						|
     SYNTAX       Integer32 (0..255)
 | 
						|
     MAX-ACCESS   not-accessible
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
          "The tertiary index into this table.  Indicates the CMTS
 | 
						|
           identifier for this physical channel."
 | 
						|
     ::= { docsIfCmtsChannelUtilizationEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsChannelUtUtilization OBJECT-TYPE
 | 
						|
     SYNTAX       Integer32 (0..100)
 | 
						|
     UNITS        "percent"
 | 
						|
     MAX-ACCESS   read-only
 | 
						|
     STATUS       current
 | 
						|
     DESCRIPTION
 | 
						|
         "The calculated and truncated utilization index for this
 | 
						|
          physical upstream or downstream channel, accurate as of
 | 
						|
          the most recent docsIfCmtsChannelUtilizationInterval.
 | 
						|
 | 
						|
          Upstream Channel Utilization Index:
 | 
						|
 | 
						|
          The upstream channel utilization index is expressed as a
 | 
						|
          percentage of mini-slots utilized on the physical channel,
 | 
						|
          regardless of burst type.  For an Initial Maintenance
 | 
						|
          region, the mini-slots for the complete region are
 | 
						|
          considered utilized if the CMTS received an upstream
 | 
						|
          burst within the region from any CM on the physical
 | 
						|
          channel.  For contention REQ and REQ/DATA regions, the
 | 
						|
          mini-slots for a transmission opportunity within the
 | 
						|
          region are considered utilized if the CMTS received an
 | 
						|
          upstream burst within the opportunity from any CM on the
 | 
						|
          physical channel.  For all other regions, utilized
 | 
						|
          mini-slots are those in which the CMTS granted
 | 
						|
          bandwidth to any unicast SID on the physical channel.
 | 
						|
 | 
						|
          For an upstream interface that has multiple logical
 | 
						|
          upstream channels enabled, the utilization index is a
 | 
						|
          weighted sum of utilization indices for the logical
 | 
						|
          channels.  The weight for each utilization index is the
 | 
						|
          percentage of upstream mini-slots allocated for the
 | 
						|
          corresponding logical channel.
 | 
						|
          Example:
 | 
						|
          If 75% of bandwidth is allocated to the first logical
 | 
						|
          channel and 25% to the second, and the utilization
 | 
						|
          indices for each are 60 and 40, respectively, the
 | 
						|
 | 
						|
          utilization index for the upstream physical channel is
 | 
						|
          (60 * 0.75) + (40 * 0.25) = 55.  This figure
 | 
						|
          applies to the most recent utilization interval.
 | 
						|
 | 
						|
          Downstream Channel Utilization Index:
 | 
						|
 | 
						|
          The downstream channel utilization index is a percentage
 | 
						|
          expressing the ratio between bytes used to transmit data
 | 
						|
          versus the total number of bytes transmitted in the raw
 | 
						|
          bandwidth of the MPEG channel.  As with the upstream
 | 
						|
          utilization index, the calculated value represents
 | 
						|
          the most recent utilization interval.
 | 
						|
          Formula:
 | 
						|
          Downstream utilization index =
 | 
						|
          (100 * (data bytes / raw bytes))
 | 
						|
 | 
						|
          Definitions:
 | 
						|
          Data bytes:    Number of bytes transmitted as data in the
 | 
						|
                         docsIfCmtsChannelUtilizationInterval.
 | 
						|
                         Identical to docsIfCmtsDownChannelCtrUsed
 | 
						|
                         Bytes measured over the utilization
 | 
						|
                         interval.
 | 
						|
          Raw bandwidth: Total number of bytes available for
 | 
						|
                         transmitting data, not including bytes
 | 
						|
                         used for headers and other overhead.
 | 
						|
          Raw bytes:     (raw bandwidth *
 | 
						|
                         docsIfCmtsChannelUtilizationInterval).
 | 
						|
                         Identical to docsIfCmtsDownChannelCtrTotal
 | 
						|
                         Bytes measured over the utilization
 | 
						|
                         interval."
 | 
						|
     ::= { docsIfCmtsChannelUtilizationEntry 3 }
 | 
						|
 | 
						|
-- The following table provides operators with input data
 | 
						|
-- appropriate for calculating downstream channel utilization.
 | 
						|
-- Operators may use the docsIfCmtsChannelUtilizationTable or
 | 
						|
-- perform their own polling of the
 | 
						|
-- docsIfCmtsDownChannelCounterTable objects to characterize
 | 
						|
-- their downstream channel usage.  The 32-bit counter objects are
 | 
						|
-- included to provide backward compatibility with SNMPv1 managers,
 | 
						|
-- which cannot access 64-bit counter objects.
 | 
						|
 | 
						|
docsIfCmtsDownChannelCounterTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsDownChannelCounterEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This table is implemented at the CMTS to collect
 | 
						|
          downstream channel statistics for utilization
 | 
						|
 | 
						|
          calculations."
 | 
						|
     ::= { docsIfCmtsObjects 10 }
 | 
						|
 | 
						|
docsIfCmtsDownChannelCounterEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsDownChannelCounterEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "An entry provides a list of traffic counters for a single
 | 
						|
          downstream channel.
 | 
						|
          An entry in this table exists for each ifEntry with an
 | 
						|
          ifType of docsCableDownstream(128)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfCmtsDownChannelCounterTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsDownChannelCounterEntry ::= SEQUENCE {
 | 
						|
         docsIfCmtsDownChnlCtrId              Integer32,
 | 
						|
         docsIfCmtsDownChnlCtrTotalBytes      Counter32,
 | 
						|
         docsIfCmtsDownChnlCtrUsedBytes       Counter32,
 | 
						|
         docsIfCmtsDownChnlCtrExtTotalBytes   Counter64,
 | 
						|
         docsIfCmtsDownChnlCtrExtUsedBytes    Counter64
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsDownChnlCtrId OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The Cable Modem Termination System identification
 | 
						|
          of the downstream channel within this particular MAC
 | 
						|
          interface.  If the interface is down, the object returns
 | 
						|
          the most current value.  If the downstream channel ID is
 | 
						|
          unknown, this object returns a value of 0."
 | 
						|
     ::= { docsIfCmtsDownChannelCounterEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsDownChnlCtrTotalBytes OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "Bytes"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CMTS, the total number of bytes in the Payload
 | 
						|
          portion of MPEG Packets (i.e., not including MPEG header
 | 
						|
          or pointer_field) transported by this downstream channel.
 | 
						|
          This is the 32-bit version of
 | 
						|
          docsIfCmtsDownChnlCtrExtTotalBytes, included to provide
 | 
						|
          back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsDownChannelCounterEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsDownChnlCtrUsedBytes OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "Bytes"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CMTS, the total number of DOCSIS data bytes
 | 
						|
          transported by this downstream channel.
 | 
						|
          The number of data bytes is defined as the total number
 | 
						|
          of bytes transported in DOCSIS payloads minus the number
 | 
						|
          of stuff bytes transported in DOCSIS payloads.
 | 
						|
          This is the 32-bit version of
 | 
						|
          docsIfCmtsDownChnlCtrExtUsedBytes, included to provide
 | 
						|
          back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsDownChannelCounterEntry 3 }
 | 
						|
 | 
						|
docsIfCmtsDownChnlCtrExtTotalBytes OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "Bytes"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CMTS, the total number of bytes in the Payload
 | 
						|
          portion of MPEG Packets (i.e., not including MPEG header
 | 
						|
          or pointer_field) transported by this downstream
 | 
						|
          channel.
 | 
						|
          This is the 64-bit version of
 | 
						|
          docsIfCmtsDownChnlCtrTotalBytes and will not be
 | 
						|
          accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsDownChannelCounterEntry 4 }
 | 
						|
 | 
						|
docsIfCmtsDownChnlCtrExtUsedBytes OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "Bytes"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "At the CMTS, the total number of DOCSIS data bytes
 | 
						|
          transported by this downstream channel.  The number
 | 
						|
          of data bytes is defined as the total number of bytes
 | 
						|
          transported in DOCSIS payloads minus the number of
 | 
						|
          stuff bytes transported in DOCSIS payloads.
 | 
						|
          This is the 64-bit version of
 | 
						|
          docsIfCmtsDownChnlCtrUsedBytes and will not be accessible
 | 
						|
          to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsDownChannelCounterEntry 5 }
 | 
						|
 | 
						|
-- The following table provides operators with input data appropriate
 | 
						|
-- for calculating upstream channel utilization, and for determining
 | 
						|
-- the traffic characteristics of upstream channels.  Operators may
 | 
						|
-- use the docsIfCmtsChannelUtilizationTable or perform their own
 | 
						|
-- polling of the docsIfCmtsUpChannelCounterTable objects for
 | 
						|
-- utilization determination.
 | 
						|
-- The first four 32 and 64 objects in this table are mandatory.
 | 
						|
-- Vendors may choose to implement the remaining optional objects to
 | 
						|
-- provide operators with finer characterization of upstream channel
 | 
						|
-- traffic patterns.  The 32-bit counter objects are included to
 | 
						|
-- provide backward compatibility with SNMPv1 managers, which cannot
 | 
						|
-- access 64-bit counter objects.
 | 
						|
 | 
						|
docsIfCmtsUpChannelCounterTable OBJECT-TYPE
 | 
						|
     SYNTAX      SEQUENCE OF DocsIfCmtsUpChannelCounterEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "This table is implemented at the CMTS to provide upstream
 | 
						|
          channel statistics appropriate for channel utilization
 | 
						|
          calculations."
 | 
						|
     ::= { docsIfCmtsObjects 11 }
 | 
						|
 | 
						|
docsIfCmtsUpChannelCounterEntry OBJECT-TYPE
 | 
						|
     SYNTAX      DocsIfCmtsUpChannelCounterEntry
 | 
						|
     MAX-ACCESS  not-accessible
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "List of traffic statistics for a single upstream channel.
 | 
						|
          For DOCSIS 2.0 CMTSs, an entry in this table
 | 
						|
          exists for each ifEntry with an ifType of
 | 
						|
          docsCableUpstreamChannel (205).
 | 
						|
 | 
						|
          For DOCSIS 1.x CMTSs, an entry in this table
 | 
						|
          exists for each ifEntry with an ifType of
 | 
						|
          docsCableUpstream (129)."
 | 
						|
     INDEX { ifIndex }
 | 
						|
     ::= { docsIfCmtsUpChannelCounterTable 1 }
 | 
						|
 | 
						|
DocsIfCmtsUpChannelCounterEntry ::= SEQUENCE {
 | 
						|
         docsIfCmtsUpChnlCtrId                          Integer32,
 | 
						|
         docsIfCmtsUpChnlCtrTotalMslots                 Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrUcastGrantedMslots          Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnMslots             Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnMslots              Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalMslots              Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtUcastGrantedMslots       Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnMslots          Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnMslots           Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnMslots              Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnReqMslots          Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnReqMslots           Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnReqMslots           Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnReqDataMslots      Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnReqDataMslots       Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnReqDataMslots       Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots    Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots     Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnInitMaintMslots     Counter32,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnMslots           Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnReqMslots       Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnReqMslots        Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnReqMslots        Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots   Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots    Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots    Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots  Counter64,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots  Counter64
 | 
						|
     }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrId OBJECT-TYPE
 | 
						|
     SYNTAX      Integer32 (0..255)
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The CMTS identification of the upstream channel."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 1 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrTotalMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of all mini-slots
 | 
						|
          defined for this upstream logical channel.  This count
 | 
						|
          includes all IUCs and SIDs, even those allocated to the
 | 
						|
          NULL SID for a 2.0 logical channel that is inactive.  This
 | 
						|
          is the 32-bit version of docsIfCmtsUpChnlCtrExtTotalMslots
 | 
						|
          and is included for back compatibility with SNMPv1
 | 
						|
          managers.  Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 2 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrUcastGrantedMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of unicast
 | 
						|
          granted mini-slots on the upstream logical channel,
 | 
						|
          regardless of burst type.  Unicast granted mini-slots are
 | 
						|
          those in which the CMTS assigned bandwidth to any unicast
 | 
						|
          SID on the logical channel.  However, this object does not
 | 
						|
          include minis-lots for reserved IUCs, or grants to SIDs
 | 
						|
          designated as meaning 'no CM'.  This is the 32-bit version
 | 
						|
          of docsIfCmtsUpChnlCtrExtUcastGrantedMslots, and is
 | 
						|
          included for back compatibility with SNMPv1 managers.
 | 
						|
          Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 3 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrTotalCntnMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          mini-slots defined for this upstream logical channel.  This
 | 
						|
          count includes all mini-slots assigned to a broadcast or
 | 
						|
 | 
						|
          multicast SID on the logical channel.  This is the 32-bit
 | 
						|
          version of docsIfCmtsUpChnlCtrExtTotalCntnMslots, and is
 | 
						|
          included for back compatibility with SNMPv1 managers.
 | 
						|
          Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 4 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrUsedCntnMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          mini-slots utilized on the upstream logical channel.  For
 | 
						|
          contention regions, utilized mini-slots are those in which
 | 
						|
          the CMTS correctly received an upstream burst from any CM
 | 
						|
          on the upstream logical channel.  This is the 32-bit
 | 
						|
          version of docsIfCmtsUpChnlCtrExtUsedCntnMslots and is
 | 
						|
          included for back compatibility with SNMPv1 managers.
 | 
						|
          Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 5 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtTotalMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of all mini-slots
 | 
						|
          defined for this upstream logical channel.  This count
 | 
						|
          includes all IUCs and SIDs, even those allocated to the
 | 
						|
          NULL SID for a 2.0 logical channel that is inactive.  This
 | 
						|
          is the 64-bit version of docsIfCmtsUpChnlCtrTotalMslots
 | 
						|
          and will not be accessible to SNMPv1 managers.
 | 
						|
          Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 6 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtUcastGrantedMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of unicast
 | 
						|
          granted mini-slots on the upstream logical channel,
 | 
						|
          regardless of burst type.  Unicast granted mini-slots are
 | 
						|
          those in which the CMTS assigned bandwidth to any unicast
 | 
						|
          SID on the logical channel.  However, this object does not
 | 
						|
          include mini-slots for reserved IUCs, or grants to SIDs
 | 
						|
          designated as meaning 'no CM'.  This is the 64-bit version
 | 
						|
          of docsIfCmtsUpChnlCtrUcastGrantedMslots and will not be
 | 
						|
          accessible to SNMPv1 managers.
 | 
						|
          Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 7 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtTotalCntnMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          mini-slots defined for this upstream logical channel.  This
 | 
						|
          count includes all mini-slots assigned to a broadcast or
 | 
						|
          multicast SID on the logical channel.  This is the 64-bit
 | 
						|
          version of docsIfCmtsUpChnlCtrTotalCntnMslots and will
 | 
						|
          not be accessible to SNMPv1 managers.
 | 
						|
          Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 8 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtUsedCntnMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
 | 
						|
          mini-slots utilized on the upstream logical channel.  For
 | 
						|
          contention regions, utilized mini-slots are those in which
 | 
						|
          the CMTS correctly received an upstream burst from any CM
 | 
						|
          on the upstream logical channel.  This is the 64-bit
 | 
						|
          version of docsIfCmtsUpChnlCtrUsedCntnMslots and will not
 | 
						|
          be accessible to SNMPv1 managers.
 | 
						|
          Support for this object is mandatory.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 9 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrCollCntnMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          mini-slots subjected to collisions on the upstream logical
 | 
						|
          channel.  For contention regions, these are the mini-slots
 | 
						|
          applicable to bursts that the CMTS detected but could not
 | 
						|
          correctly receive.  This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtCollCntnMslots and is included for
 | 
						|
          back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 10 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrTotalCntnReqMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request mini-slots defined for this upstream logical
 | 
						|
          channel.  This count includes all mini-slots for IUC1
 | 
						|
          assigned to a broadcast or multicast SID on the logical
 | 
						|
          channel.  This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtTotalCntnReqMslots and is included
 | 
						|
          for back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 11 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrUsedCntnReqMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request mini-slots utilized on this upstream logical
 | 
						|
          channel.  This count includes all contention mini-slots for
 | 
						|
          IUC1 applicable to bursts that the CMTS correctly
 | 
						|
          received.  This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtUsedCntnReqMslots and is included
 | 
						|
          for back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 12 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrCollCntnReqMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request mini-slots subjected to collisions on this upstream
 | 
						|
          logical channel.  This includes all contention mini-slots
 | 
						|
          for IUC1 applicable to bursts that the CMTS detected but
 | 
						|
          could not correctly receive.  This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtCollCntnReqMslots and is included
 | 
						|
          for back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 13 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrTotalCntnReqDataMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
 | 
						|
          request data mini-slots defined for this upstream logical
 | 
						|
          channel.  This count includes all mini-slots for IUC2
 | 
						|
          assigned to a broadcast or multicast SID on the logical
 | 
						|
          channel.  This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots and is
 | 
						|
          included for back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 14 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrUsedCntnReqDataMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request data mini-slots utilized on this upstream logical
 | 
						|
          channel.  This includes all contention mini-slots for IUC2
 | 
						|
          applicable to bursts that the CMTS correctly received.
 | 
						|
          This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots and is
 | 
						|
          included for back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 15 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrCollCntnReqDataMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request data mini-slots subjected to collisions on this
 | 
						|
          upstream logical channel.  This includes all contention
 | 
						|
          mini-slots for IUC2 applicable to bursts that the CMTS
 | 
						|
          detected, but could not correctly receive.  This is the
 | 
						|
          32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots and is
 | 
						|
          included for back compatibility with SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 16 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          initial maintenance mini-slots defined for this upstream
 | 
						|
          logical channel.  This includes all mini-slots for IUC3
 | 
						|
          assigned to a broadcast or multicast SID on the logical
 | 
						|
          channel.  This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots
 | 
						|
          and is included for back compatibility with SNMPv1
 | 
						|
          managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 17 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          initial maintenance mini-slots utilized on this upstream
 | 
						|
          logical channel.  This includes all contention mini-slots
 | 
						|
          for IUC3 applicable to bursts that the CMTS correctly
 | 
						|
          received.  This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots
 | 
						|
          and is included for back compatibility with SNMPv1
 | 
						|
          managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 18 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrCollCntnInitMaintMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter32
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          initial maintenance mini-slots subjected to collisions on
 | 
						|
          this upstream logical channel.  This includes all
 | 
						|
          contention mini-slots for IUC3 applicable to bursts that
 | 
						|
          the CMTS detected, but could not correctly receive.
 | 
						|
          This is the 32-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots
 | 
						|
          and is included for back compatibility with SNMPv1
 | 
						|
          managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 19 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtCollCntnMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of collision
 | 
						|
          contention mini-slots on the upstream logical channel.
 | 
						|
          For contention regions, these are the mini-slots applicable
 | 
						|
          to bursts that the CMTS detected, but could not correctly
 | 
						|
          receive.  This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrCollCntnMslots and will not be
 | 
						|
          accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 20 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtTotalCntnReqMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request mini-slots defined for this upstream logical
 | 
						|
          channel.  This count includes all mini-slots for IUC1
 | 
						|
          assigned to a broadcast or multicast SID on the logical
 | 
						|
          channel.  This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrTotalCntnReqMslots and will not be
 | 
						|
          accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 21 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtUsedCntnReqMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request mini-slots utilized on this upstream logical
 | 
						|
          channel.  This count includes all contention mini-slots for
 | 
						|
          IUC1 applicable to bursts that the CMTS correctly
 | 
						|
          received.  This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrUsedCntnReqMslots and will not be
 | 
						|
          accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 22 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtCollCntnReqMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request mini-slots subjected to collisions on this upstream
 | 
						|
          logical channel.  This includes all contention mini-slots
 | 
						|
          for IUC1 applicable to bursts that the CMTS detected,
 | 
						|
          but could not correctly receive.  This is the 64-bit
 | 
						|
          version of docsIfCmtsUpChnlCtrCollCntnReqMslots and will
 | 
						|
          not be accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 23 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request data mini-slots defined for this upstream logical
 | 
						|
          channel.  This count includes all mini-slots for IUC2
 | 
						|
          assigned to a broadcast or multicast SID on the logical
 | 
						|
          channel.  This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrTotalCntnReqDataMslots and will not be
 | 
						|
          accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 24 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request data mini-slots utilized on this upstream logical
 | 
						|
          channel.  This includes all contention mini-slots for IUC2
 | 
						|
          applicable to bursts that the CMTS correctly received.
 | 
						|
          This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrUsedCntnReqDataMslots and will not be
 | 
						|
          accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 25 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          request data mini-slots subjected to collisions on this
 | 
						|
          upstream logical channel.  This includes all contention
 | 
						|
          mini-slots for IUC2 applicable to bursts that the CMTS
 | 
						|
          detected, but could not correctly receive.  This is the
 | 
						|
          64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrCollCntnReqDataMslots
 | 
						|
          and will not be accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 26 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of initial
 | 
						|
          maintenance mini-slots defined for this upstream logical
 | 
						|
          channel.  This count includes all mini-slots for IUC3
 | 
						|
          assigned to a broadcast or multicast SID on the logical
 | 
						|
          channel.  This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots
 | 
						|
          and will not be accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 27 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of initial
 | 
						|
          maintenance mini-slots utilized on this upstream logical
 | 
						|
          channel.  This includes all contention mini-slots for IUC3
 | 
						|
          applicable to bursts that the CMTS correctly received.
 | 
						|
          This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots
 | 
						|
          and will not be accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 28 }
 | 
						|
 | 
						|
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots OBJECT-TYPE
 | 
						|
     SYNTAX      Counter64
 | 
						|
     UNITS       "mini-slots"
 | 
						|
     MAX-ACCESS  read-only
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Current count, from CMTS initialization, of contention
 | 
						|
          initial maintenance mini-slots subjected to collisions on
 | 
						|
          this upstream logical channel.  This includes all
 | 
						|
          contention mini-slots for IUC3 applicable to bursts that
 | 
						|
          the CMTS detected, but could not correctly receive.
 | 
						|
          This is the 64-bit version of
 | 
						|
          docsIfCmtsUpChnlCtrCollCntnInitMaintMslots and will not
 | 
						|
          be accessible to SNMPv1 managers.
 | 
						|
          Discontinuities in the value of this counter can occur
 | 
						|
          at reinitialization of the managed system, and at other
 | 
						|
          times as indicated by the value of
 | 
						|
          ifCounterDiscontinuityTime for the associated ifIndex."
 | 
						|
     ::= { docsIfCmtsUpChannelCounterEntry 29 }
 | 
						|
 | 
						|
--
 | 
						|
-- notification group is for future extension.
 | 
						|
--
 | 
						|
 | 
						|
docsIfNotification OBJECT IDENTIFIER     ::= { docsIfMib 2 }
 | 
						|
 | 
						|
--
 | 
						|
-- MIB Compliance statements.
 | 
						|
--
 | 
						|
 | 
						|
--
 | 
						|
-- Conformance definitions
 | 
						|
--
 | 
						|
 | 
						|
docsIfConformance  OBJECT IDENTIFIER     ::= { docsIfMib 3 }
 | 
						|
docsIfCompliances  OBJECT IDENTIFIER     ::= { docsIfConformance 1 }
 | 
						|
docsIfGroups       OBJECT IDENTIFIER     ::= { docsIfConformance 2 }
 | 
						|
 | 
						|
docsIfBasicCompliance MODULE-COMPLIANCE
 | 
						|
     STATUS      deprecated
 | 
						|
     DESCRIPTION
 | 
						|
         "The compliance statement for devices that implement
 | 
						|
          DOCSIS 1.x compliant Radio Frequency Interfaces."
 | 
						|
 | 
						|
MODULE  -- docsIfMib
 | 
						|
 | 
						|
-- unconditionally mandatory groups
 | 
						|
MANDATORY-GROUPS {
 | 
						|
     docsIfBasicGroup
 | 
						|
     }
 | 
						|
 | 
						|
-- conditionally mandatory group
 | 
						|
GROUP docsIfCmGroup
 | 
						|
     DESCRIPTION
 | 
						|
         "This group is implemented only in cable modems, not in
 | 
						|
          cable modem termination systems."
 | 
						|
 | 
						|
-- conditionally mandatory group
 | 
						|
GROUP docsIfCmtsGroup
 | 
						|
     DESCRIPTION
 | 
						|
         "This group is implemented only in cable modem termination
 | 
						|
          systems, not in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelFrequency
 | 
						|
     WRITE-SYNTAX Integer32 (54000000..860000000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems.  The values above are
 | 
						|
          appropriate for a cable plant using a Sub-Split channel
 | 
						|
          plan.  If DOCSIS is extended to cover other types of
 | 
						|
          channel plans (and frequency allocations), this object
 | 
						|
          will be modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelWidth
 | 
						|
     WRITE-SYNTAX Integer32 (6000000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is important to implement this object as read-only.
 | 
						|
          In cable modems, this object is always implemented as
 | 
						|
          read-only.  The above value is appropriate for cable
 | 
						|
          plants running under NTSC (National Television
 | 
						|
          Standards Committee) standards.  If DOCSIS is extended to
 | 
						|
          work with other standards (e.g., European standards), this
 | 
						|
          object will be modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelModulation
 | 
						|
     WRITE-SYNTAX INTEGER {
 | 
						|
                            qam64 (3),
 | 
						|
                            qam256 (4)
 | 
						|
                          }
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelInterleave
 | 
						|
     WRITE-SYNTAX INTEGER {
 | 
						|
                 taps8Increment16(3),
 | 
						|
                 taps16Increment8(4),
 | 
						|
                 taps32Increment4(5),
 | 
						|
                 taps64Increment2(6),
 | 
						|
                 taps128Increment1(7)
 | 
						|
                  }
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelPower
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelFrequency
 | 
						|
     WRITE-SYNTAX Integer32 (5000000..42000000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems.  The values above are
 | 
						|
          appropriate for a cable plant using a Sub-Split channel
 | 
						|
          plan.  If DOCSIS is extended to cover other types of
 | 
						|
          channel plans (and frequency allocations), this object
 | 
						|
          will be modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelWidth
 | 
						|
     WRITE-SYNTAX Integer32 (200000..3200000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems.  The above value is appropriate
 | 
						|
          for cable plants running under NTSC (National Television
 | 
						|
          Standards Committee) standards.  If DOCSIS is extended to
 | 
						|
          work with other standards (e.g., European standards), this
 | 
						|
          object will be modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelModulationProfile
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelSlotSize
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelRangingBackoffStart
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelRangingBackoffEnd
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelTxBackoffStart
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelTxBackoffEnd
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfPriority
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfMaxUpBandwidth
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfGuarUpBandwidth
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfMaxDownBandwidth
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfMaxTxBurst
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfBaselinePrivacy
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfStatus
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsServiceAdminStatus
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsSyncInterval
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsUcdInterval
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsInsertInterval
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsInvitedRangingAttempts
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsQosProfilePermissions
 | 
						|
     WRITE-SYNTAX     BITS {
 | 
						|
         createByManagement(0),
 | 
						|
         updateByManagement(1)
 | 
						|
        }
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT docsIfCmtsModType
 | 
						|
     WRITE-SYNTAX INTEGER {
 | 
						|
                     qpsk (2),
 | 
						|
                     qam16 (3)
 | 
						|
                      }
 | 
						|
     DESCRIPTION
 | 
						|
         "A management station MAY only set 16QAM or QPSK modulation,
 | 
						|
          but others might be possible, based on device
 | 
						|
          configuration."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsModPreambleLen
 | 
						|
     SYNTAX Integer32 (0..1024)
 | 
						|
     DESCRIPTION
 | 
						|
         "The range of the values for this MODULE-COMPLIANCE
 | 
						|
          is 0..1024."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsModFECErrorCorrection
 | 
						|
        SYNTAX Integer32 (0..10)
 | 
						|
        DESCRIPTION
 | 
						|
            "The range of the values for this MODULE-COMPLIANCE
 | 
						|
             is 0..10."
 | 
						|
     ::= { docsIfCompliances 1 }
 | 
						|
 | 
						|
docsIfBasicComplianceV2 MODULE-COMPLIANCE
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "The compliance statement for devices that implement
 | 
						|
          DOCSIS 2.0 Radio Frequency Interfaces."
 | 
						|
 | 
						|
MODULE  -- docsIfMib
 | 
						|
 | 
						|
-- unconditionally mandatory groups
 | 
						|
MANDATORY-GROUPS {
 | 
						|
     docsIfBasicGroupV2
 | 
						|
     }
 | 
						|
 | 
						|
-- conditionally mandatory group
 | 
						|
GROUP docsIfCmGroupV2
 | 
						|
     DESCRIPTION
 | 
						|
         "This group is implemented only in cable modems, not in
 | 
						|
          cable modem termination systems."
 | 
						|
 | 
						|
-- conditionally mandatory group
 | 
						|
GROUP docsIfCmtsGroupV2
 | 
						|
     DESCRIPTION
 | 
						|
         "This group is implemented only in cable modem termination
 | 
						|
          systems, not in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelFrequency
 | 
						|
     WRITE-SYNTAX Integer32 (47000000..862000000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems.
 | 
						|
          A range of 54MHz to 860MHz is appropriate for a cable
 | 
						|
          plant using a North American Sub-Split channel plan.
 | 
						|
          The spectrum range has been expanded to accommodate
 | 
						|
          a lower edge of 47MHz and an upper edge of 862MHz
 | 
						|
          for some European channel plans.
 | 
						|
          If DOCSIS is extended to cover other types of channel
 | 
						|
          plans (and frequency allocations), this object will be
 | 
						|
          modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelWidth
 | 
						|
     WRITE-SYNTAX Integer32 (6000000 | 8000000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is important to implement this object as read-only.
 | 
						|
          In cable modems, this object is always implemented as
 | 
						|
          read-only.  The value of 6 MHz is appropriate for cable
 | 
						|
          plants running under NTSC (National Television
 | 
						|
          Standards Committee) standards.  The value of 8 MHz is
 | 
						|
          appropriate for cable plants running under ETSI
 | 
						|
          standards.  For other regional standards, this
 | 
						|
          object will be modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelModulation
 | 
						|
     WRITE-SYNTAX INTEGER {
 | 
						|
                            qam64 (3),
 | 
						|
                            qam256 (4)
 | 
						|
                          }
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelInterleave
 | 
						|
     WRITE-SYNTAX INTEGER {
 | 
						|
                 taps8Increment16(3),
 | 
						|
                 taps16Increment8(4),
 | 
						|
                 taps32Increment4(5),
 | 
						|
                 taps64Increment2(6),
 | 
						|
                 taps128Increment1(7),
 | 
						|
                 taps12increment17(8)
 | 
						|
                  }
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfDownChannelPower
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-write in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelFrequency
 | 
						|
     WRITE-SYNTAX Integer32 (5000000..65000000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems.
 | 
						|
          A range of 5MHz to 42MHz is appropriate for a cable
 | 
						|
          plant using a North American Sub-Split channel plan.
 | 
						|
          The spectrum range has been expanded to accommodate
 | 
						|
          an upper edge of 65MHz for some European channel plans.
 | 
						|
          If DOCSIS is extended to cover other types of channel
 | 
						|
          plans (and frequency allocations), this object will
 | 
						|
          be modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelWidth
 | 
						|
     WRITE-SYNTAX Integer32 (200000..6400000)
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems,
 | 
						|
          read-only in cable modems.  The above value is appropriate
 | 
						|
          for cable plants running under NTSC (National Television
 | 
						|
          Standards Committee) standards.  If DOCSIS is extended to
 | 
						|
          work with other standards (e.g., European standards), this
 | 
						|
          object will be modified accordingly."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelModulationProfile
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelSlotSize
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelRangingBackoffStart
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelRangingBackoffEnd
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelTxBackoffStart
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelTxBackoffEnd
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelScdmaActiveCodes
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems.
 | 
						|
          The number of active codes when SCDMA is in use MUST range
 | 
						|
          from 64 to 128 and MUST be a non-Prime value.
 | 
						|
          Providing this range allows for the following features
 | 
						|
          and capabilities:
 | 
						|
             1) Power management in S-CDMA spreader-on frames
 | 
						|
                (with a 3 dB spread).
 | 
						|
 | 
						|
             2) Avoidance of code 0.
 | 
						|
             3) Flexible mini-slot sizes with and without the use of
 | 
						|
                code 0."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelScdmaCodesPerSlot
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelScdmaFrameSize
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelScdmaHoppingSeed
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelCloneFrom
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelUpdate
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelStatus
 | 
						|
        MIN-ACCESS  read-only
 | 
						|
        DESCRIPTION
 | 
						|
            "Read-create in Cable Modem Termination Systems;
 | 
						|
             read-only in Cable Modems.
 | 
						|
             Entries associated to physical interfaces only support
 | 
						|
             the read-only value 'active'."
 | 
						|
 | 
						|
OBJECT  docsIfUpChannelPreEqEnable
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "Read-create in cable modem termination systems;
 | 
						|
          read-only in cable modems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfPriority
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfMaxUpBandwidth
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfGuarUpBandwidth
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfMaxDownBandwidth
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfBaselinePrivacy
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfStatus
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfQosProfMaxTransmitBurst
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "This object is always read-only in cable modems.
 | 
						|
          It is compliant to implement this object as read-only
 | 
						|
          in cable modem termination systems."
 | 
						|
 | 
						|
OBJECT  docsIfCmRangingTimeout
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT docsIfCmStatusModulationType
 | 
						|
    SYNTAX          INTEGER {
 | 
						|
        unknown(0),
 | 
						|
        tdma(1),
 | 
						|
        atdma(2),
 | 
						|
        scdma(3)
 | 
						|
    }
 | 
						|
     DESCRIPTION
 | 
						|
         "CM does not use both modulation burst profiles of a
 | 
						|
          'tdmAndAtdma' ChannelType; therefore, 'tdmAndAtdma'is
 | 
						|
          not supported."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsServiceAdminStatus
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsSyncInterval
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsUcdInterval
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsInsertInterval
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsInvitedRangingAttempts
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT  docsIfCmtsQosProfilePermissions
 | 
						|
     WRITE-SYNTAX     BITS {
 | 
						|
         createByManagement(0),
 | 
						|
         updateByManagement(1)
 | 
						|
        }
 | 
						|
     MIN-ACCESS  read-only
 | 
						|
     DESCRIPTION
 | 
						|
         "It is compliant to implement this object as read-only."
 | 
						|
 | 
						|
OBJECT docsIfCmtsModType
 | 
						|
     WRITE-SYNTAX      INTEGER {
 | 
						|
         qpsk(2),
 | 
						|
         qam16(3),
 | 
						|
         qam64(6)
 | 
						|
     }
 | 
						|
     DESCRIPTION
 | 
						|
         "A management station MAY only set 64QAM, 16QAM, or QPSK
 | 
						|
          modulation for Time or Code division Multiple Access,
 | 
						|
          but others might be possible based on device
 | 
						|
          configuration."
 | 
						|
 | 
						|
OBJECT docsIfCmtsCmStatusModulationType
 | 
						|
    SYNTAX          INTEGER {
 | 
						|
        unknown(0),
 | 
						|
        tdma(1),
 | 
						|
        atdma(2),
 | 
						|
        scdma(3)
 | 
						|
    }
 | 
						|
     DESCRIPTION
 | 
						|
         "CM does not use both modulation burst profiles of a
 | 
						|
          'tdmAndAtdma' ChannelType; therefore, 'tdmAndAtdma'is
 | 
						|
          not supported."
 | 
						|
     ::= { docsIfCompliances 2 }
 | 
						|
 | 
						|
docsIfBasicGroup OBJECT-GROUP
 | 
						|
     OBJECTS {
 | 
						|
         docsIfDownChannelId,
 | 
						|
         docsIfDownChannelFrequency,
 | 
						|
         docsIfDownChannelWidth,
 | 
						|
         docsIfDownChannelModulation,
 | 
						|
         docsIfDownChannelInterleave,
 | 
						|
         docsIfDownChannelPower,
 | 
						|
         docsIfUpChannelId,
 | 
						|
         docsIfUpChannelFrequency,
 | 
						|
         docsIfUpChannelWidth,
 | 
						|
         docsIfUpChannelModulationProfile,
 | 
						|
         docsIfUpChannelSlotSize,
 | 
						|
         docsIfUpChannelTxTimingOffset,
 | 
						|
         docsIfUpChannelRangingBackoffStart,
 | 
						|
         docsIfUpChannelRangingBackoffEnd,
 | 
						|
         docsIfUpChannelTxBackoffStart,
 | 
						|
         docsIfUpChannelTxBackoffEnd,
 | 
						|
         docsIfQosProfPriority,
 | 
						|
         docsIfQosProfMaxUpBandwidth,
 | 
						|
         docsIfQosProfGuarUpBandwidth,
 | 
						|
         docsIfQosProfMaxDownBandwidth,
 | 
						|
         docsIfQosProfMaxTxBurst,
 | 
						|
         docsIfQosProfBaselinePrivacy,
 | 
						|
         docsIfQosProfStatus,
 | 
						|
         docsIfSigQIncludesContention,
 | 
						|
         docsIfSigQUnerroreds,
 | 
						|
         docsIfSigQCorrecteds,
 | 
						|
         docsIfSigQUncorrectables,
 | 
						|
         docsIfSigQSignalNoise,
 | 
						|
         docsIfSigQMicroreflections,
 | 
						|
         docsIfSigQEqualizationData
 | 
						|
     }
 | 
						|
     STATUS      deprecated
 | 
						|
     DESCRIPTION
 | 
						|
         "Group of objects implemented in both cable modems and
 | 
						|
          cable modem termination systems."
 | 
						|
     ::= { docsIfGroups 1 }
 | 
						|
 | 
						|
docsIfCmGroup OBJECT-GROUP
 | 
						|
     OBJECTS {
 | 
						|
         docsIfCmCmtsAddress,
 | 
						|
         docsIfCmCapabilities,
 | 
						|
         docsIfCmRangingTimeout,
 | 
						|
         docsIfCmStatusValue,
 | 
						|
         docsIfCmStatusCode,
 | 
						|
         docsIfCmStatusTxPower,
 | 
						|
         docsIfCmStatusResets,
 | 
						|
         docsIfCmStatusLostSyncs,
 | 
						|
         docsIfCmStatusInvalidMaps,
 | 
						|
         docsIfCmStatusInvalidUcds,
 | 
						|
         docsIfCmStatusInvalidRangingResponses,
 | 
						|
         docsIfCmStatusInvalidRegistrationResponses,
 | 
						|
         docsIfCmStatusT1Timeouts,
 | 
						|
         docsIfCmStatusT2Timeouts,
 | 
						|
         docsIfCmStatusT3Timeouts,
 | 
						|
         docsIfCmStatusT4Timeouts,
 | 
						|
         docsIfCmStatusRangingAborteds,
 | 
						|
         docsIfCmServiceQosProfile,
 | 
						|
         docsIfCmServiceTxSlotsImmed,
 | 
						|
         docsIfCmServiceTxSlotsDed,
 | 
						|
         docsIfCmServiceTxRetries,
 | 
						|
         docsIfCmServiceTxExceededs,
 | 
						|
         docsIfCmServiceRqRetries,
 | 
						|
         docsIfCmServiceRqExceededs
 | 
						|
     }
 | 
						|
     STATUS      deprecated
 | 
						|
     DESCRIPTION
 | 
						|
         "Group of objects implemented in cable modems."
 | 
						|
     ::= { docsIfGroups 2 }
 | 
						|
 | 
						|
docsIfCmtsGroup OBJECT-GROUP
 | 
						|
     OBJECTS {
 | 
						|
         docsIfCmtsCapabilities,
 | 
						|
         docsIfCmtsSyncInterval,
 | 
						|
         docsIfCmtsUcdInterval,
 | 
						|
         docsIfCmtsMaxServiceIds,
 | 
						|
         docsIfCmtsInvitedRangingAttempts,
 | 
						|
         docsIfCmtsInsertInterval,
 | 
						|
         docsIfCmtsStatusInvalidRangeReqs,
 | 
						|
         docsIfCmtsStatusRangingAborteds,
 | 
						|
         docsIfCmtsStatusInvalidRegReqs,
 | 
						|
         docsIfCmtsStatusFailedRegReqs,
 | 
						|
         docsIfCmtsStatusInvalidDataReqs,
 | 
						|
         docsIfCmtsStatusT5Timeouts,
 | 
						|
         docsIfCmtsCmStatusMacAddress,
 | 
						|
         docsIfCmtsCmStatusIpAddress,
 | 
						|
         docsIfCmtsCmStatusDownChannelIfIndex,
 | 
						|
         docsIfCmtsCmStatusUpChannelIfIndex,
 | 
						|
         docsIfCmtsCmStatusRxPower,
 | 
						|
         docsIfCmtsCmStatusTimingOffset,
 | 
						|
         docsIfCmtsCmStatusEqualizationData,
 | 
						|
         docsIfCmtsCmStatusValue,
 | 
						|
         docsIfCmtsCmStatusUnerroreds,
 | 
						|
         docsIfCmtsCmStatusCorrecteds,
 | 
						|
         docsIfCmtsCmStatusUncorrectables,
 | 
						|
         docsIfCmtsCmStatusSignalNoise,
 | 
						|
         docsIfCmtsCmStatusMicroreflections,
 | 
						|
         docsIfCmtsServiceCmStatusIndex,
 | 
						|
         docsIfCmtsServiceAdminStatus,
 | 
						|
         docsIfCmtsServiceQosProfile,
 | 
						|
         docsIfCmtsServiceCreateTime,
 | 
						|
         docsIfCmtsServiceInOctets,
 | 
						|
         docsIfCmtsServiceInPackets,
 | 
						|
         docsIfCmtsModType,
 | 
						|
         docsIfCmtsModControl,
 | 
						|
         docsIfCmtsModPreambleLen,
 | 
						|
         docsIfCmtsModDifferentialEncoding,
 | 
						|
         docsIfCmtsModFECErrorCorrection,
 | 
						|
         docsIfCmtsModFECCodewordLength,
 | 
						|
         docsIfCmtsModScramblerSeed,
 | 
						|
         docsIfCmtsModMaxBurstSize,
 | 
						|
         docsIfCmtsModGuardTimeSize,
 | 
						|
         docsIfCmtsModLastCodewordShortened,
 | 
						|
         docsIfCmtsModScrambler,
 | 
						|
         docsIfCmtsQosProfilePermissions,
 | 
						|
         docsIfCmtsCmPtr
 | 
						|
     }
 | 
						|
     STATUS      deprecated
 | 
						|
     DESCRIPTION
 | 
						|
         "Group of objects implemented in Cable Modem Termination
 | 
						|
          Systems."
 | 
						|
     ::= { docsIfGroups 3 }
 | 
						|
 | 
						|
-- obsolete group
 | 
						|
-- RFC 2670 already had a obsolete group, even though RFC2670
 | 
						|
-- was the first version of this MIB Module.
 | 
						|
 | 
						|
docsIfObsoleteGroup OBJECT-GROUP
 | 
						|
     OBJECTS {
 | 
						|
         docsIfCmRangingRespTimeout,
 | 
						|
         docsIfCmtsInsertionInterval
 | 
						|
     }
 | 
						|
     STATUS      obsolete
 | 
						|
     DESCRIPTION
 | 
						|
         "Group of objects obsoleted."
 | 
						|
     ::= { docsIfGroups 4 }
 | 
						|
 | 
						|
docsIfBasicGroupV2 OBJECT-GROUP
 | 
						|
     OBJECTS {
 | 
						|
         docsIfDownChannelId,
 | 
						|
         docsIfDownChannelFrequency,
 | 
						|
         docsIfDownChannelWidth,
 | 
						|
         docsIfDownChannelModulation,
 | 
						|
         docsIfDownChannelInterleave,
 | 
						|
         docsIfDownChannelPower,
 | 
						|
         docsIfDownChannelAnnex,
 | 
						|
         docsIfUpChannelId,
 | 
						|
         docsIfUpChannelFrequency,
 | 
						|
         docsIfUpChannelWidth,
 | 
						|
         docsIfUpChannelModulationProfile,
 | 
						|
         docsIfUpChannelSlotSize,
 | 
						|
         docsIfUpChannelTxTimingOffset,
 | 
						|
         docsIfUpChannelRangingBackoffStart,
 | 
						|
         docsIfUpChannelRangingBackoffEnd,
 | 
						|
         docsIfUpChannelTxBackoffStart,
 | 
						|
         docsIfUpChannelTxBackoffEnd,
 | 
						|
         docsIfUpChannelScdmaActiveCodes,
 | 
						|
         docsIfUpChannelScdmaCodesPerSlot,
 | 
						|
         docsIfUpChannelScdmaFrameSize,
 | 
						|
         docsIfUpChannelScdmaHoppingSeed,
 | 
						|
         docsIfUpChannelType,
 | 
						|
         docsIfUpChannelCloneFrom,
 | 
						|
         docsIfUpChannelUpdate,
 | 
						|
         docsIfUpChannelStatus,
 | 
						|
         docsIfUpChannelPreEqEnable,
 | 
						|
         docsIfQosProfPriority,
 | 
						|
         docsIfQosProfMaxUpBandwidth,
 | 
						|
         docsIfQosProfGuarUpBandwidth,
 | 
						|
         docsIfQosProfMaxDownBandwidth,
 | 
						|
         docsIfQosProfBaselinePrivacy,
 | 
						|
         docsIfQosProfStatus,
 | 
						|
         docsIfQosProfMaxTransmitBurst,
 | 
						|
         docsIfSigQIncludesContention,
 | 
						|
         docsIfSigQUnerroreds,
 | 
						|
         docsIfSigQCorrecteds,
 | 
						|
         docsIfSigQUncorrectables,
 | 
						|
         docsIfSigQSignalNoise,
 | 
						|
         docsIfSigQMicroreflections,
 | 
						|
         docsIfSigQExtUnerroreds,
 | 
						|
         docsIfSigQExtCorrecteds,
 | 
						|
         docsIfSigQExtUncorrectables,
 | 
						|
         docsIfDocsisBaseCapability
 | 
						|
     }
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Group of objects implemented in both cable modems and
 | 
						|
          cable modem termination systems."
 | 
						|
     ::= { docsIfGroups 5 }
 | 
						|
 | 
						|
docsIfCmGroupV2 OBJECT-GROUP
 | 
						|
     OBJECTS {
 | 
						|
         docsIfCmCmtsAddress,
 | 
						|
         docsIfCmCapabilities,
 | 
						|
         docsIfCmRangingTimeout,
 | 
						|
         docsIfCmStatusValue,
 | 
						|
         docsIfCmStatusCode,
 | 
						|
         docsIfCmStatusTxPower,
 | 
						|
         docsIfCmStatusResets,
 | 
						|
         docsIfCmStatusLostSyncs,
 | 
						|
         docsIfCmStatusInvalidMaps,
 | 
						|
         docsIfCmStatusInvalidUcds,
 | 
						|
         docsIfCmStatusInvalidRangingResponses,
 | 
						|
         docsIfCmStatusInvalidRegistrationResponses,
 | 
						|
         docsIfCmStatusT1Timeouts,
 | 
						|
         docsIfCmStatusT2Timeouts,
 | 
						|
         docsIfCmStatusT3Timeouts,
 | 
						|
         docsIfCmStatusT4Timeouts,
 | 
						|
         docsIfCmStatusRangingAborteds,
 | 
						|
         docsIfCmStatusDocsisOperMode,
 | 
						|
         docsIfCmStatusModulationType,
 | 
						|
         docsIfCmStatusEqualizationData,
 | 
						|
         docsIfCmStatusUCCs,
 | 
						|
         docsIfCmStatusUCCFails,
 | 
						|
         docsIfCmServiceQosProfile,
 | 
						|
         docsIfCmServiceTxSlotsImmed,
 | 
						|
         docsIfCmServiceTxSlotsDed,
 | 
						|
         docsIfCmServiceTxRetries,
 | 
						|
         docsIfCmServiceTxExceededs,
 | 
						|
         docsIfCmServiceRqRetries,
 | 
						|
         docsIfCmServiceRqExceededs,
 | 
						|
         docsIfCmServiceExtTxSlotsImmed,
 | 
						|
         docsIfCmServiceExtTxSlotsDed,
 | 
						|
         docsIfSigQEqualizationData
 | 
						|
     }
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Group of objects implemented in cable modems."
 | 
						|
     ::= { docsIfGroups 6 }
 | 
						|
 | 
						|
docsIfCmtsGroupV2 OBJECT-GROUP
 | 
						|
     OBJECTS {
 | 
						|
         docsIfCmtsCapabilities,
 | 
						|
         docsIfCmtsSyncInterval,
 | 
						|
         docsIfCmtsUcdInterval,
 | 
						|
         docsIfCmtsMaxServiceIds,
 | 
						|
         docsIfCmtsInvitedRangingAttempts,
 | 
						|
         docsIfCmtsInsertInterval,
 | 
						|
         docsIfCmtsMacStorageType,
 | 
						|
         docsIfCmtsStatusInvalidRangeReqs,
 | 
						|
         docsIfCmtsStatusRangingAborteds,
 | 
						|
         docsIfCmtsStatusInvalidRegReqs,
 | 
						|
         docsIfCmtsStatusFailedRegReqs,
 | 
						|
         docsIfCmtsStatusInvalidDataReqs,
 | 
						|
         docsIfCmtsStatusT5Timeouts,
 | 
						|
         docsIfCmtsCmStatusMacAddress,
 | 
						|
         docsIfCmtsCmStatusDownChannelIfIndex,
 | 
						|
         docsIfCmtsCmStatusUpChannelIfIndex,
 | 
						|
         docsIfCmtsCmStatusRxPower,
 | 
						|
         docsIfCmtsCmStatusTimingOffset,
 | 
						|
         docsIfCmtsCmStatusEqualizationData,
 | 
						|
         docsIfCmtsCmStatusValue,
 | 
						|
         docsIfCmtsCmStatusUnerroreds,
 | 
						|
         docsIfCmtsCmStatusCorrecteds,
 | 
						|
         docsIfCmtsCmStatusUncorrectables,
 | 
						|
         docsIfCmtsCmStatusSignalNoise,
 | 
						|
         docsIfCmtsCmStatusMicroreflections,
 | 
						|
         docsIfCmtsCmStatusExtUnerroreds,
 | 
						|
         docsIfCmtsCmStatusExtCorrecteds,
 | 
						|
         docsIfCmtsCmStatusExtUncorrectables,
 | 
						|
         docsIfCmtsCmStatusDocsisRegMode,
 | 
						|
         docsIfCmtsCmStatusModulationType,
 | 
						|
         docsIfCmtsCmStatusInetAddressType,
 | 
						|
         docsIfCmtsCmStatusInetAddress,
 | 
						|
         docsIfCmtsCmStatusValueLastUpdate,
 | 
						|
         docsIfCmtsCmStatusHighResolutionTimingOffset,
 | 
						|
         docsIfCmtsServiceAdminStatus,
 | 
						|
         docsIfCmtsServiceQosProfile,
 | 
						|
         docsIfCmtsServiceCreateTime,
 | 
						|
         docsIfCmtsServiceInOctets,
 | 
						|
         docsIfCmtsServiceInPackets,
 | 
						|
         docsIfCmtsServiceNewCmStatusIndex,
 | 
						|
         docsIfCmtsModType,
 | 
						|
         docsIfCmtsModControl,
 | 
						|
         docsIfCmtsModPreambleLen,
 | 
						|
         docsIfCmtsModDifferentialEncoding,
 | 
						|
         docsIfCmtsModFECErrorCorrection,
 | 
						|
         docsIfCmtsModFECCodewordLength,
 | 
						|
         docsIfCmtsModScramblerSeed,
 | 
						|
         docsIfCmtsModMaxBurstSize,
 | 
						|
         docsIfCmtsModGuardTimeSize,
 | 
						|
         docsIfCmtsModLastCodewordShortened,
 | 
						|
         docsIfCmtsModScrambler,
 | 
						|
         docsIfCmtsModByteInterleaverDepth,
 | 
						|
         docsIfCmtsModByteInterleaverBlockSize,
 | 
						|
         docsIfCmtsModPreambleType,
 | 
						|
         docsIfCmtsModTcmErrorCorrectionOn,
 | 
						|
         docsIfCmtsModScdmaInterleaverStepSize,
 | 
						|
         docsIfCmtsModScdmaSpreaderEnable,
 | 
						|
         docsIfCmtsModScdmaSubframeCodes,
 | 
						|
         docsIfCmtsModChannelType,
 | 
						|
         docsIfCmtsModStorageType,
 | 
						|
         docsIfCmtsQosProfilePermissions,
 | 
						|
         docsIfCmtsCmPtr,
 | 
						|
         docsIfCmtsChannelUtilizationInterval,
 | 
						|
         docsIfCmtsChannelUtUtilization,
 | 
						|
         docsIfCmtsDownChnlCtrId,
 | 
						|
         docsIfCmtsDownChnlCtrTotalBytes,
 | 
						|
         docsIfCmtsDownChnlCtrUsedBytes,
 | 
						|
         docsIfCmtsDownChnlCtrExtTotalBytes,
 | 
						|
         docsIfCmtsDownChnlCtrExtUsedBytes,
 | 
						|
         docsIfCmtsUpChnlCtrId,
 | 
						|
         docsIfCmtsUpChnlCtrTotalMslots,
 | 
						|
         docsIfCmtsUpChnlCtrUcastGrantedMslots,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnMslots,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtUcastGrantedMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnMslots,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnMslots,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnReqMslots,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnReqMslots,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnReqMslots,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnReqDataMslots,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnReqDataMslots,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnReqDataMslots,
 | 
						|
         docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots,
 | 
						|
         docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots,
 | 
						|
         docsIfCmtsUpChnlCtrCollCntnInitMaintMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnReqMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnReqMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnReqMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots,
 | 
						|
         docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots,
 | 
						|
         docsIfDownChannelStorageType,
 | 
						|
         docsIfQosProfStorageType
 | 
						|
 | 
						|
     }
 | 
						|
     STATUS      current
 | 
						|
     DESCRIPTION
 | 
						|
         "Group of objects implemented in Cable Modem Termination
 | 
						|
          Systems."
 | 
						|
     ::= { docsIfGroups 7 }
 | 
						|
 | 
						|
END
 |