-- sle-faultmgmt-mib.mib
|
||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
||
-- Tuesday, April 12, 2016 at 17:15:30
|
||
--
|
||
|
||
SLE-FAULTMGMT-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
sleMgmt
|
||
FROM DASAN-SMI
|
||
SleControlStatusType, SleControlRequestResultType
|
||
FROM SLE-TC-MIB
|
||
OBJECT-GROUP, NOTIFICATION-GROUP
|
||
FROM SNMPv2-CONF
|
||
TimeTicks, IpAddress, Integer32, Unsigned32, Gauge32,
|
||
Counter32, Counter64, BITS, OBJECT-TYPE, MODULE-IDENTITY,
|
||
NOTIFICATION-TYPE
|
||
FROM SNMPv2-SMI
|
||
MacAddress, TimeStamp, TEXTUAL-CONVENTION
|
||
FROM SNMPv2-TC;
|
||
|
||
|
||
sleFaultMgmt MODULE-IDENTITY
|
||
LAST-UPDATED "201008130000Z" -- August 13, 2010 at 00:00 GMT
|
||
ORGANIZATION
|
||
" DASAN Networks"
|
||
CONTACT-INFO
|
||
"
|
||
"
|
||
DESCRIPTION
|
||
"The MIB module representing multiple logical
|
||
entities for the SLE alarm management. "
|
||
REVISION "190412080000Z" -- December 08, 1904 at 00:00 GMT
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleMgmt 4 }
|
||
|
||
|
||
|
||
--
|
||
-- Textual conventions
|
||
--
|
||
|
||
SpecificNum ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
SYNTAX INTEGER
|
||
{
|
||
portDown(1),
|
||
portUp(2),
|
||
portRemoved(3),
|
||
portInstalled(4),
|
||
powerFail(5),
|
||
powerOK(6),
|
||
powerRemoved(7),
|
||
powerInstalled(8),
|
||
fanFail(9),
|
||
fanOK(10),
|
||
fanRemoved(11),
|
||
fanInstalled(12),
|
||
moduleRemoved(13),
|
||
moduleInstalled(14),
|
||
systemRestart(15),
|
||
systemStart(16),
|
||
broadcastOver(17),
|
||
broadcastUnder(18),
|
||
cpuOverLoad(19),
|
||
cpuUnderLoad(20),
|
||
memoryOverUsed(21),
|
||
memoryUnderUsed(22),
|
||
portOverThreshold(23),
|
||
portUnderThreshold(24),
|
||
temperatureHigh(25),
|
||
temperatureLow(26),
|
||
mfgdBlocked(27),
|
||
mfgdReleased(28),
|
||
ipConflict(29),
|
||
ipUnconflict(30),
|
||
dhcpLeaseShortage(31),
|
||
dhcpLeaseSufficient(32),
|
||
dhcpOccuredIllegalEntry(33),
|
||
dhcpRemovedIllegalEntry(34),
|
||
rmonAlarmRising(35),
|
||
rmonAlarmNoRising(36),
|
||
rmonAlarmFalling(37),
|
||
rmonAlarmNoFalling(38),
|
||
bpduGuardDisabled(39),
|
||
rootGuardDisabled(40),
|
||
portSecurity(41),
|
||
userLogin(42),
|
||
userLogout(43),
|
||
systemWarmStart(44),
|
||
igmpGroupJoined(51),
|
||
igmpGroupLeaved(52),
|
||
dhcpIpaddressBound(53),
|
||
dhcpIpaddressFree(54),
|
||
doorOpened(55),
|
||
doorClosed(56),
|
||
powerModeChangedPowerToBattery(57),
|
||
powerModeChangedBatteryToPower(58),
|
||
batterylowcapacity(59),
|
||
batterynormalcapacity(60),
|
||
batteryhighTemperature(61),
|
||
batterynormalTemperature(62),
|
||
authenticationFail(63),
|
||
authenticationNoFail(64),
|
||
psuAcHighTemperature(65),
|
||
psuAcNormalTemperature(66),
|
||
batteryRemoved(67),
|
||
batteryEquipped(68),
|
||
batteryLowVoltage(69),
|
||
batteryNormalVoltage(70),
|
||
adminAccessLogin(71),
|
||
adminAccessLogout(72),
|
||
cfgdBlocked(73),
|
||
cfgdReleased(74),
|
||
sfgdBlocked(75),
|
||
sfgdReleased(76),
|
||
swWatchdogAbnomalState(77),
|
||
swWatchdogNomalState(78),
|
||
swWatchdogDetectError(79),
|
||
swWatchdogClearError(80),
|
||
ppsControlBlocked(81),
|
||
ppsControlReleased(82),
|
||
gotDMITempHighOverAlarm(83),
|
||
gotDMITempHighFallAlarm(84),
|
||
gotDMITempLowOverAlarm(85),
|
||
gotDMITempLowFallAlarm(86),
|
||
gotDMITempHighOverWarning(87),
|
||
gotDMITempHighFallWarning(88),
|
||
gotDMITempLowOverWarning(89),
|
||
gotDMITempLowFallWarning(90),
|
||
gotDMIVolHighOverAlarm(91),
|
||
gotDMIVolHighFallAlarm(92),
|
||
gotDMIVolLowOverAlarm(93),
|
||
gotDMIVolLowFallAlarm(94),
|
||
gotDMIVolHighOverWarning(95),
|
||
gotDMIVolHighFallWarning(96),
|
||
gotDMIVolLowOverWarning(97),
|
||
gotDMIVolLowFallWarning(98),
|
||
gotDMITxBiasHighOverAlarm(99),
|
||
gotDMITxBiasHighFallAlarm(100),
|
||
gotDMITxBiasLowOverAlarm(101),
|
||
gotDMITxBiasLowFallAlarm(102),
|
||
gotDMITxBiasHighOverWarning(103),
|
||
gotDMITxBiasHighFallWarning(104),
|
||
gotDMITxBiasLowOverWarning(105),
|
||
gotDMITxBiasLowFallWarning(106),
|
||
gotDMITxPowerHighOverAlarm(107),
|
||
gotDMITxPowerHighFallAlarm(108),
|
||
gotDMITxPowerLowOverAlarm(109),
|
||
gotDMITxPowerLowFallAlarm(110),
|
||
gotDMITxPowerHighOverWarning(111),
|
||
gotDMITxPowerHighFallWarning(112),
|
||
gotDMITxPowerLowOverWarning(113),
|
||
gotDMITxPowerLowFallWarning(114),
|
||
gotDMIRxPowerHighOverAlarm(115),
|
||
gotDMIRxPowerHighFallAlarm(116),
|
||
gotDMIRxPowerLowOverAlarm(117),
|
||
gotDMIRxPowerLowFallAlarm(118),
|
||
gotDMIRxPowerHighOverWarning(119),
|
||
gotDMIRxPowerHighFallWarning(120),
|
||
gotDMIRxPowerLowOverWarning(121),
|
||
gotDMIRxPowerLowFallWarning(122),
|
||
nosRemoteUpgradeRequest(123),
|
||
nosRemoteUpgradeSuccess(124),
|
||
nosRemoteUpgradeFailAbort(125),
|
||
nosRemoteUpgradeFailHeaderError(126),
|
||
nosRemoteUpgradeFailDownloadError(127),
|
||
nosRemoteUpgradeFailFlashError(128),
|
||
nosRemoteUpgradeStart(129),
|
||
systemDyingGasp(130),
|
||
remoteOamDyingGasp(131),
|
||
remoteOamDyingGaspRestoration(132),
|
||
cliHistory(133),
|
||
cliHistoryNo(134),
|
||
ntpConnectionFail(135),
|
||
nmsConnectionTypeChanged(137),
|
||
fanSpeedFallUnderThreshold(138),
|
||
fanSpeedRisingOverThreshold(139),
|
||
userLoginFail(140),
|
||
temperatureHighContinued(142),
|
||
swWatchdogInetAbnormalState(150),
|
||
swWatchdogInetNormalState(151),
|
||
swWatchdogInetDetectError(152),
|
||
swWatchdogInetClearError(153),
|
||
swWatchdogPonAbnormalState(154),
|
||
swWatchdogPonNormalState(155),
|
||
swWatchdogPonDetectError(156),
|
||
swWatchdogPonClearError(157),
|
||
arpInspectInvalid(158),
|
||
clockModuleRemoved(159),
|
||
clockModuleInstalled(160),
|
||
clockModuleInitFail(161),
|
||
clockModuleInitOk(162),
|
||
cliHistoryLog(163),
|
||
cliHistoryLogNo(164),
|
||
slotActionEvent(165),
|
||
slotStateChange(166),
|
||
interfaceAdminDown(167),
|
||
interfaceAdminUp(168),
|
||
slotPowerMonAbnormal(169),
|
||
slotPowerMonNormal(170),
|
||
slotErrorLEDChanged(171),
|
||
bfdSessionStateChanged(172),
|
||
clockModuleOPModeChanged(173),
|
||
clockModuleRefChanged(174),
|
||
clockModuleInSrcStatusChanged(175),
|
||
clockModuleInSrcAISStatusChanged(176),
|
||
clockModuleInSrcLoSStatusChanged(177),
|
||
clockModuleInSrcLSDCStatusChanged(178),
|
||
clockModuleInSrcNtrClockChanged(179),
|
||
portRxOverThreshold(181),
|
||
portRxUnderThreshold(182),
|
||
portTxOverThreshold(183),
|
||
portTxUnderThreshold(184),
|
||
cpuPpsOverThreshold(185),
|
||
cpuPpsUnderThreshold(186),
|
||
pairFanPowerOff(191),
|
||
pairFanPowerOn(192),
|
||
slotHealthStatusTimeout(199),
|
||
slotHealthStatusTimeoutCleared(200),
|
||
advaTemperature(201),
|
||
advaTemperatureNo(202),
|
||
advaPSUFailure(203),
|
||
advaPSUFailureNo(204),
|
||
advaFanFailure(205),
|
||
advaFanFailureNo(206),
|
||
advaInterfaceReceiveFailure(207),
|
||
advaInterfaceReceiveFailureNo(208),
|
||
advaInterfaceOpticalThreshold(209),
|
||
advaInterfaceOpticalThresholdNo(210),
|
||
advaInterfaceTransmitFault(211),
|
||
advaInterfaceTransmitFaultNo(212),
|
||
advaInterfaceMisconfiguration(213),
|
||
advaInterfaceMisconfigurationNo(214),
|
||
advaInterfaceSFPMismatch(215),
|
||
advaInterfaceSFPMismatchNo(216),
|
||
advaVoltageLow(217),
|
||
advaVoltageLowNo(218),
|
||
advaVoltageHigh(219),
|
||
advaVoltageHighNo(220),
|
||
criticalAlarmLedOn(251),
|
||
criticalAlarmLedOff(252),
|
||
majorAlarmLedOn(253),
|
||
majorAlarmLedOff(254),
|
||
minorAlarmLedOn(255),
|
||
minorAlarmLedOff(256),
|
||
systemTemperPowerCutOff(291),
|
||
systemTemperPowerCutoffCleared(292),
|
||
slotTemperPowerCutOff(294),
|
||
erpDomainLotp(301),
|
||
erpDomainLotpNo(302),
|
||
erpDomainULotp(303),
|
||
erpDomainULotpNo(304),
|
||
erpDomainMultipleRM(305),
|
||
erpDomainMultipleRMNo(306),
|
||
erpDomainRMNodeReacheablity(307),
|
||
erpDomainRMNodeReacheablityNo(308),
|
||
startupConfigLoadEnded(391),
|
||
eponOnuDeregister(401),
|
||
eponOnuRegister(402),
|
||
eponOnuRegistrationError(403),
|
||
eponOnuNoRegistrationError(404),
|
||
eponBadEncryptionKey(405),
|
||
eponNoBadEncryptionKey(406),
|
||
eponLlidMistmatch(407),
|
||
eponNoLlidMismatch(408),
|
||
eponTooManyRegister(409),
|
||
eponNoTooManyRegister(410),
|
||
eponDyingGASP(411),
|
||
eponNoDyingGASP(412),
|
||
eponOnuErrFramePeriod(413),
|
||
eponOnuNoErrFramePeriod(414),
|
||
eponOnuErrFrame(415),
|
||
eponOnuNoErrFrame(416),
|
||
eponOnuErrFrameSecondSummary(417),
|
||
eponOnuNoErrFrameSecondSummary(418),
|
||
eponOnuLastOnuDeregister(419),
|
||
eponOnuNoLastOnuDeregister(420),
|
||
eponOltCableDown(421),
|
||
eponOltRecoverCableDown(422),
|
||
eponOltHealthCheckError(423),
|
||
eponOnuOpticSignalErr(424),
|
||
eponOnuRecoverOpticSignalErr(425),
|
||
standardLinkFault(428),
|
||
standardLinkFaultCleared(429),
|
||
lossOfSignal(430),
|
||
lossOfSignalCleared(431),
|
||
transmitFail(432),
|
||
transmitFailCleared(433),
|
||
macLearningOverflow(434),
|
||
macLearningOverflowCleared(435),
|
||
loopback(436),
|
||
loopbackCleared(437),
|
||
standardDyinggasp(438),
|
||
standardDyinggaspCleared(439),
|
||
externalDyinggasp(440),
|
||
externalDyinggaspCleared(441),
|
||
standardCriticalEvent(442),
|
||
standardCriticalEventCleared(443),
|
||
externalCriticalEvent(444),
|
||
externalCriticalEventCleared(445),
|
||
eponStandbyLos(446),
|
||
eponStandbyLosCleared(447),
|
||
eponOnuPingTest(448),
|
||
eponOnuDmiThresholdTemperOverHighWarn(450),
|
||
clearEponOnuDmiThresholdTemperOverHighWarn(451),
|
||
eponOnuDmiThresholdTemperFallLowWarn(452),
|
||
clearEponOnuDmiThresholdTemperFallLowWarn(453),
|
||
eponOnuDmiThresholdTemperOverHighAlarm(454),
|
||
clearEponOnuDmiThresholdTemperOverHighAlarm(455),
|
||
eponOnuDmiThresholdTemperFallLowAlarm(456),
|
||
clearEponOnuDmiThresholdTemperFallLowAlarm(457),
|
||
eponOnuDmiThresholdVoltageOverHighWarn(458),
|
||
clearEponOnuDmiThresholdVoltageOverHighWarn(459),
|
||
eponOnuDmiThresholdVoltageFallLowWarn(460),
|
||
clearEponOnuDmiThresholdVoltageFallLowWarn(461),
|
||
eponOnuDmiThresholdVoltageOverHighAlarm(462),
|
||
clearEponOnuDmiThresholdVoltageOverHighAlarm(463),
|
||
eponOnuDmiThresholdVoltageFallLowAlarm(464),
|
||
clearEponOnuDmiThresholdVoltageFallLowAlarm(465),
|
||
eponOnuDmiThresholdTxbiasOverHighWarn(466),
|
||
clearEponOnuDmiThresholdTxbiasOverHighWarn(467),
|
||
eponOnuDmiThresholdTxbiasFallLowWarn(468),
|
||
clearEponOnuDmiThresholdTxbiasFallLowWarn(469),
|
||
eponOnuDmiThresholdTxbiasOverHighAlarm(470),
|
||
clearEponOnuDmiThresholdTxbiasOverHighAlarm(471),
|
||
eponOnuDmiThresholdTxbiasFallLowAlarm(472),
|
||
clearEponOnuDmiThresholdTxbiasFallLowAlarm(473),
|
||
eponOnuDmiThresholdTxpowerOverHighWarn(474),
|
||
clearEponOnuDmiThresholdTxpowerOverHighWarn(475),
|
||
eponOnuDmiThresholdTxpowerFallLowWarn(476),
|
||
clearEponOnuDmiThresholdTxpowerFallLowWarn(477),
|
||
eponOnuDmiThresholdTxpowerOverHighAlarm(478),
|
||
clearEponOnuDmiThresholdTxpowerOverHighAlarm(479),
|
||
eponOnuDmiThresholdTxpowerFallLowAlarm(480),
|
||
clearEponOnuDmiThresholdTxpowerFallLowAlarm(481),
|
||
eponOnuDmiThresholdRxpowerOverHighWarn(482),
|
||
clearEponOnuDmiThresholdRxpowerOverHighWarn(483),
|
||
eponOnuDmiThresholdRxpowerFallLowWarn(484),
|
||
clearEponOnuDmiThresholdRxpowerFallLowWarn(485),
|
||
eponOnuDmiThresholdRxpowerOverHighAlarm(486),
|
||
clearEponOnuDmiThresholdRxpowerOverHighAlarm(487),
|
||
eponOnuDmiThresholdRxpowerFallLowAlarm(488),
|
||
clearEponOnuDmiThresholdRxpowerFallLowAlarm(489),
|
||
eponDetectRouge(490),
|
||
clearEpoonDetectRouge(491),
|
||
eponDetectRougeOnuPowerOff(492),
|
||
eponDetectRougeOnuPowerOffFailed(493),
|
||
eponDetectRougeOnuDeregisterSuccess(494),
|
||
eponDetectRougeOnuDeregisterFailed(495),
|
||
eponDetectRougeOnuFoundFailed(496),
|
||
eponOltRedundancyDetectRxpower(497),
|
||
clearEponOltRedundancyDetectRxpower(498),
|
||
eponOltRedundancySwitchoverReasonForce(499),
|
||
eponOltRedundancySwitchoverReasonLos(500),
|
||
autoCLIStart(501),
|
||
autoCLINoStart(502),
|
||
autoCLIComplete(503),
|
||
autoCLINoComplete(504),
|
||
autoCLIRemoveOutputFile(505),
|
||
autoCLINoRemoveOutputFile(506),
|
||
autoResetSystem(507),
|
||
autoResetNoSystem(508),
|
||
autoResetPingReplyLoss(509),
|
||
autoResetNoPingReplyLoss(510),
|
||
autoResetMemoryLeakDetect(511),
|
||
autoResetNoMemoryLeakDetect(512),
|
||
loopDetectBlocked(551),
|
||
loopDetectUnBlockedByExpireTimer(552),
|
||
loopDetectUnBlockedByLinkDown(553),
|
||
loopDetectUnBlockedByClearCmd(554),
|
||
oamRemoteTestLoopback(562),
|
||
arulePacketDropDetect(601),
|
||
arulePacketDropRelease(602),
|
||
autoCpeUpgradeStart(605),
|
||
autoCpeUpgradeFail(607),
|
||
autoCpeUpgradeSuccess(609),
|
||
batteryUnderTemper(611),
|
||
batteryTemperUnderToNormal(612),
|
||
batteryCellAbnormal(613),
|
||
batteryCellNormal(614),
|
||
batteryCellTestChargeStarted(615),
|
||
batteryCellTestChargeFinished(616),
|
||
batteryAcPowerFault(617),
|
||
batteryAcPowerOk(618),
|
||
bME1CardNoDetect(620),
|
||
clearBME1CardNoDetect(621),
|
||
bME1CardAFEerror(622),
|
||
clearBME1CardAFEerror(623),
|
||
bME1CardIFEerror(624),
|
||
clearBME1CardIFEerror(625),
|
||
bME1CardFWerror(626),
|
||
clearBME1CardFWerror(627),
|
||
bME1CardPROVerror(628),
|
||
clearBME1CardPROVerror(629),
|
||
bME1CrashDetect(630),
|
||
clearBME1CrashDetect(631),
|
||
bME2CardNoDetect(632),
|
||
clearBME2CardNoDetect(633),
|
||
bME2CardAFEerror(634),
|
||
clearBME2CardAFEerror(635),
|
||
bME2CardIFEerror(636),
|
||
clearBME2CardIFEerror(637),
|
||
bME2CardFWerror(638),
|
||
clearBME2CardFWerror(639),
|
||
bME2CardPROVerror(640),
|
||
clearBME2CardPROVerror(641),
|
||
bME2CrashDetect(642),
|
||
clearBME2CrashDetect(643),
|
||
bME3CardNoDetect(644),
|
||
clearBME3CardNoDetect(645),
|
||
bME3CardAFEerror(646),
|
||
clearBME3CardAFEerror(647),
|
||
bME3CardIFEerror(648),
|
||
clearBME3CardIFEerror(649),
|
||
bME3CardFWerror(650),
|
||
clearBME3CardFWerror(651),
|
||
bME3CardPROVerror(652),
|
||
clearBME3CardPROVerror(653),
|
||
bME3CrashDetect(654),
|
||
clearBME3CrashDetect(655),
|
||
powerFromBattery(656),
|
||
clearPowerFromBattery(657),
|
||
invalidBatteryStatus(658),
|
||
clearInvalidBatteryStatus(659),
|
||
batteryChargeLow(660),
|
||
clearBatteryChargeLow(661),
|
||
batteryNotPresent(662),
|
||
clearBatteryNotPresent(663),
|
||
voltageLow(664),
|
||
clearVoltageLow(665),
|
||
tempOverThreshold(666),
|
||
clearTempOverThreshold(667),
|
||
tempUnderThreshold(668),
|
||
clearTempUnderThreshold(669),
|
||
cpuOverThreshold(670),
|
||
clearCpuOverThreshold(671),
|
||
trafficOverload(672),
|
||
clearTrafficOverload(673),
|
||
gEPONModuleNotDetect(674),
|
||
clearGEPONModuleNotDetect(675),
|
||
gEPONPortOperationDown(676),
|
||
clearGEPONPortOperationDown(677),
|
||
gEPONNoIncomingTraffic(678),
|
||
clearGEPONNoIncomingTraffic(679),
|
||
processCrashDetect(680),
|
||
clearProcessCrashDetect(681),
|
||
memoryLeakDetect(682),
|
||
clearMemoryLeakDetect(683),
|
||
memoryCorrupDetect(684),
|
||
clearMemoryCorrupDetect(685),
|
||
memoryLowDetect(686),
|
||
clearMemoryLowDetect(687),
|
||
dataLineerror(688),
|
||
clearDataLineerror(689),
|
||
addressLineerror(690),
|
||
clearAddressLineerror(691),
|
||
chipsetNotDetcet(692),
|
||
clearChipsetNotDetcet(693),
|
||
pciBuserror(694),
|
||
clearPciBuserror(695),
|
||
securityAdminConnect(696),
|
||
clearSecurityAdminConnect(697),
|
||
oNUPowerDown(698),
|
||
clearONUPowerDown(699),
|
||
oNUNotRegister(700),
|
||
clearONUNotRegister(701),
|
||
oNTOpticPre(702),
|
||
clearONTOpticPre(703),
|
||
writeMemroyFailSeveralTimes(721),
|
||
writeMemroyFailSeveralTimesCleared(722),
|
||
switchoverInitiated(800),
|
||
switchoverDone(801),
|
||
boardChangeState(802),
|
||
redConfigurationMisMatch(803),
|
||
aiuAlarmInput1(851),
|
||
aiuAlarmInput1Cleared(852),
|
||
aiuAlarmInput2(853),
|
||
aiuAlarmInput2Cleared(854),
|
||
aiuAlarmInput3(855),
|
||
aiuAlarmInput3Cleared(856),
|
||
aiuAlarmInput4(857),
|
||
aiuAlarmInput4Cleared(858),
|
||
aiuSlotUninstalled(859),
|
||
aiuSlotInstalled(860),
|
||
gponNoAuthCBU(901),
|
||
gponDuplicateONU(902),
|
||
gponDyingGasp(903),
|
||
gponUpgradeComplete(904),
|
||
gponDeregistered(905),
|
||
gponRegistered(906),
|
||
gponRogueOnu(907),
|
||
gponOnuBatteryEvent(908),
|
||
clearGponOnuBetteryEvent(909),
|
||
gponOnuPortOperStatus(910),
|
||
gponTransceiverChanged(911),
|
||
gponOltLosOn(912),
|
||
gponOltLosOff(913),
|
||
gponOltLosiOn(914),
|
||
gponOltLosiOff(915),
|
||
gponDyingGaspOn(916),
|
||
gponDyingGaspOff(917),
|
||
gponOntOSUpgradeStatus(918),
|
||
gponOntBLUpgradeStatus(919),
|
||
gponOltRxPowerLoss(920),
|
||
gponOltRxPowerDetected(921),
|
||
gponOnuTemperatureHighOverThreshold(922),
|
||
gponOnuTemperatureHighFallThreshold(923),
|
||
gponOnuTemperatureLowOverThreshold(924),
|
||
gponOnuTemperatureLowFallThreshold(925),
|
||
gponOnuCpuOverThreshold(926),
|
||
gponOnuCpuFallThreshold(927),
|
||
gponOnuMemoryOverThreshold(928),
|
||
gponOnuMemoryFallThreshold(929),
|
||
gponOnuI2cFail(930),
|
||
gponOnuRxOpticLowThreshAlarmOn(931),
|
||
gponOnuRxOpticLowThreshAlarmOff(932),
|
||
gponOnuRxOpticHighThreshAlarmOn(933),
|
||
gponOnuRxOpticHighThreshAlarmOff(934),
|
||
gponOltLOFIOn(935),
|
||
gponOltLOFIOff(936),
|
||
gponOltDOWOn(937),
|
||
gponOltDOWOff(938),
|
||
gponOltSFOn(939),
|
||
gponOltSFOff(940),
|
||
gponOltSDOn(941),
|
||
gponOltSDOff(942),
|
||
gponOltLCDGIOn(943),
|
||
gponOltLCDGIOff(944),
|
||
gponOltRDOn(945),
|
||
gponOltRDOff(946),
|
||
gponOltSUFOn(947),
|
||
gponOltSUFOff(948),
|
||
gponOltLOAOn(949),
|
||
gponOltLOAOff(950),
|
||
gponOltLOAMIOn(951),
|
||
gponOltLOAMIOff(952),
|
||
gponOltMEMOn(953),
|
||
gponOltMEMOff(954),
|
||
gponOltPEEOn(955),
|
||
gponOltPEEOff(956),
|
||
gponOltPSTOn(957),
|
||
gponOltPSTOff(958),
|
||
gponOltERROn(959),
|
||
gponOltERROff(960),
|
||
gponOltREIOn(961),
|
||
gponOltREIOff(962),
|
||
gponAntiSpoofingDupPortOn(963),
|
||
gponAntiSpoofingDupPortOff(964),
|
||
gponRedundancySwitchOver(965),
|
||
gponDuplicatedRangingResponse(966),
|
||
gponOnuPortOpticModuleRemove(967),
|
||
gponOnuPortOpticModuleInstall(968),
|
||
gponOnuOMCCProblemDetected(969),
|
||
gponOnuOMCCProblemCleared(970),
|
||
gponOltFixedTcontAlarmOn(971),
|
||
gponOltFixedTcontAlarmOff(972),
|
||
gponOltDynamicTcontAlarmOn(973),
|
||
gponOltDynamicTcontAlarmOff(974),
|
||
gponOltPortCountAlarmOn(975),
|
||
gponOltPortCountAlarmOff(976),
|
||
gponOltCableDownAlarmOn(977),
|
||
gponOltCableDownAlarmOff(978),
|
||
gponOltDeactiveMonitorAlarmOn(979),
|
||
gponOltDeactiveMonitorAlarmOff(980),
|
||
gponOltDfiOn(981),
|
||
gponOltDfiOff(982),
|
||
gponOltTransceiverPortChanged(984),
|
||
gponOnuPortOperStatusDown(985),
|
||
gponOnuPortOperStatusUp(986),
|
||
gponOltRxPowerHighOver(987),
|
||
gponOltRxPowerHighCleared(988),
|
||
gponOltRxPowerLowUnder(989),
|
||
gponOltRxPowerLowCleared(990),
|
||
oamRapsEastPortStatusChanged(1001),
|
||
oamRapsWestPortStatusChanged(1002),
|
||
oamURNodePortStatusChanged(1003),
|
||
oamRemoteLlcfLinkDown(1008),
|
||
oamRemoteLlcfLinkUp(1009),
|
||
oamInterfaceStatusChanged(1010),
|
||
oamMepRDIDetected(1011),
|
||
oamMepRDICleared(1012),
|
||
oamMepLOCDetected(1013),
|
||
oamMepLOCCleared(1014),
|
||
oamMepUNPDetected(1015),
|
||
oamMepUNPCleared(1016),
|
||
oamMepUNMDetected(1017),
|
||
oamMepUNMCleared(1018),
|
||
oamMepMMGDetected(1019),
|
||
oamMepMMGCleared(1020),
|
||
oamMepUNLDetected(1021),
|
||
oamMepUNLCleared(1022),
|
||
oamMepAISDetected(1023),
|
||
oamMepAISCleared(1024),
|
||
oamMepLCKDetected(1025),
|
||
oamMepLCKCleared(1026),
|
||
oamMepMISSINGDetected(1027),
|
||
oamMepMISSINGCleared(1028),
|
||
voipPortStatusEnabled(1051),
|
||
voipPortStatusDisabled(1052),
|
||
emLogDefectCPUHighOver(1101),
|
||
emLogDefectCPUHighUnder(1102),
|
||
emLogTemperHighOver(1103),
|
||
emLogTemperHighUnder(1104),
|
||
emLogTemperLowUnder(1105),
|
||
emLogTemperLowOver(1106),
|
||
emLogMemLowUnder(1107),
|
||
emLogMemLowOver(1108),
|
||
emLogFanFail(1109),
|
||
emLogFanFailCleared(1110),
|
||
emLogPhyCRCFail(1111),
|
||
emLogPhyCRCFailCleared(1112),
|
||
emLogPhyDetectFail(1113),
|
||
emLogPhyDetectFailCleared(1114),
|
||
emLogSFUMateInitFail(1115),
|
||
emLogSFUMateInitFailCleared(1116),
|
||
emLogDaemonHealthBad(1117),
|
||
emLogDaemonHealthBadCleared(1118),
|
||
emLogGPIURavenLinkDown(1119),
|
||
emLogGPIURavenLinkDownCleared(1120),
|
||
emLogRPMLow(1121),
|
||
emLogRPMLowCleared(1122),
|
||
emLogNAKError(1123),
|
||
emLogNAKErrorCleared(1124),
|
||
snmpAllConfCleared(1141),
|
||
slotNosUpgradeStart(1151),
|
||
slotNosUpgradeEnd(1152),
|
||
autonegoMissmatedSpeed(1171),
|
||
autonegoMissmatedDuplex(1172),
|
||
autonegoMismatched(1174),
|
||
dmiTempHighOverDurationAlarmOld(1201),
|
||
dmiTempLowFallDurationAlarmOld(1202),
|
||
dmiTempHighOverDurationWarningOld(1203),
|
||
dmiTempLowFallDurationWarningOld(1204),
|
||
dmiVolHighOverDurationAlarmOld(1205),
|
||
dmiVolLowFallDurationAlarmOld(1206),
|
||
dmiVolHighOverDurationWarningOld(1207),
|
||
dmiVolLowFallDurationWarningOld(1208),
|
||
dmiTxBiasHighOverDurationAlarmOld(1209),
|
||
dmiTxBiasLowFallDurationAlarmOld(1210),
|
||
dmiTxBiasHighOverDurationWarningOld(1211),
|
||
dmiTxBiasLowFallDurationWarningOld(1212),
|
||
dmiTxPowerHighOverDurationAlarmOld(1213),
|
||
dmiTxPowerLowFallDurationAlarmOld(1214),
|
||
dmiTxPowerHighOverDurationWarningOld(1215),
|
||
dmiTxPowerLowFallDurationWarningOld(1216),
|
||
dmiRxPowerHighOverDurationAlarmOld(1217),
|
||
dmiRxPowerLowFallDurationAlarmOld(1218),
|
||
dmiRxPowerHighOverDurationWarningOld(1219),
|
||
dmiRxPowerLowFallDurationWarningOld(1220),
|
||
attackGuard(1221),
|
||
attackGuardNo(1222),
|
||
activeLinkDown(1223),
|
||
activeLinkDownNo(1224),
|
||
activeLinkUp(1225),
|
||
activeLinkUpNo(1226),
|
||
redundantLinkDown(1227),
|
||
redundantLinkDownNo(1228),
|
||
redundantLinkUp(1229),
|
||
redundantLinkUpNo(1230),
|
||
inputErrorThreshold(1231),
|
||
inputErrorThresholdNo(1232),
|
||
overSizeFrameThreshold(1233),
|
||
overSizeFrameThresholdNo(1234),
|
||
configLoadFail(1235),
|
||
configLoadFailNo(1236),
|
||
nosLoadFail(1237),
|
||
nosLoadFailNo(1238),
|
||
securityViolation(1239),
|
||
securityViolationNo(1240),
|
||
selfTestCompleted(1241),
|
||
selfTestCompletedNo(1242),
|
||
risingAlarm(1243),
|
||
risingAlarmNo(1244),
|
||
fallingAlarm(1245),
|
||
fallingAlarmNo(1246),
|
||
newRoot(1247),
|
||
newRootNo(1248),
|
||
topologyChange(1249),
|
||
topologyChangeNo(1250),
|
||
broadcastStormStart(1251),
|
||
broadcastStormStartNo(1252),
|
||
broadcastStormEnd(1253),
|
||
broadcastStormEndNo(1254),
|
||
duplicateMac(1255),
|
||
duplicateMacNo(1256),
|
||
trapLog(1257),
|
||
trapLogNo(1258),
|
||
scriptLoadFail(1259),
|
||
scriptLoadFailNo(1260),
|
||
monitorEvent(1261),
|
||
monitorEventNo(1262),
|
||
powerDetectFail(1263),
|
||
powerDetectOk(1264),
|
||
underSizeFrameThreshold(1265),
|
||
underSizeFrameThresholdNo(1266),
|
||
runtFrameThreshold(1267),
|
||
runtFrameThresholdNo(1268),
|
||
dyingGasp(1269),
|
||
dyingGaspNo(1270),
|
||
voipPortStatusEnable(1271),
|
||
voipPortStatusDisable(1272),
|
||
fanStop(1281),
|
||
fanRun(1282),
|
||
mllcfLinkDown(1301),
|
||
mllcfLinkUp(1302),
|
||
gponOnuAniVoltageLowThreshAlarmOn(1331),
|
||
gponOnuAniVoltageLowThreshAlarmOff(1332),
|
||
gponOnuAniVoltageHighThreshAlarmOn(1333),
|
||
gponOnuAniVoltageHighThreshAlarmOff(1334),
|
||
gponOnuAniTemperatureLowThreshAlarmOn(1335),
|
||
gponOnuAniTemperatureLowThreshAlarmOff(1336),
|
||
gponOnuAniTemperatureHighThreshAlarmOn(1337),
|
||
gponOnuAniTemperatureHighThreshAlarmOff(1338),
|
||
gponOnuAniTxBiasLowThreshAlarmOn(1339),
|
||
gponOnuAniTxBiasLowThreshAlarmOff(1340),
|
||
gponOnuAniTxBiasHighThreshAlarmOn(1341),
|
||
gponOnuAniTxBiasHighThreshAlarmOff(1342),
|
||
gponOnuAniTxpowerLowThreshAlarmOn(1343),
|
||
gponOnuAniTxpowerLowThreshAlarmOff(1344),
|
||
gponOnuAniTxpowerHighThreshAlarmOn(1345),
|
||
gponOnuAniTxpowerHighThreshAlarmOff(1346),
|
||
gponOnuServiceOpModeAlarm(1347),
|
||
gponOnuServiceOpModeAlarmCleared(1348),
|
||
gponOnuAuthErrorReasonUpdated(1350),
|
||
portThresholdTxOverAlarm(1351),
|
||
portThresholdTxOverAlarmCleared(1352),
|
||
portThresholdTxOverWarn(1353),
|
||
portThresholdTxOverWarnCleared(1354),
|
||
portThresholdRxOverAlarm(1355),
|
||
portThresholdRxOverAlarmCleared(1356),
|
||
portThresholdRxOverWarn(1357),
|
||
portThresholdRxOverWarnCleared(1358),
|
||
tempThresholdHighOverAlarm(1361),
|
||
tempThresholdHighOverAlarmCleared(1362),
|
||
tempThresholdLowOverAlarm(1363),
|
||
tempThresholdLowOverAlarmCleared(1364),
|
||
tempThresholdHighOverWarn(1365),
|
||
tempThresholdHighOverWarnCleared(1366),
|
||
tempThresholdLowOverWarn(1367),
|
||
tempThresholdLowOverWarnCleared(1368),
|
||
moduleDmiReadError(1381),
|
||
moduleDmiReadErrorCleared(1382),
|
||
stormControlRxOver(1391),
|
||
stormControlRxOverCleared(1392),
|
||
rmonCrcAlignErrorRising(1401),
|
||
rmonCrcAlignErrorRisingCleared(1402),
|
||
rmonJabberRising(1403),
|
||
rmonJabberRisingCleared(1404),
|
||
rmonOversizePacketRising(1405),
|
||
rmonOversizePacketRisingCleared(1406),
|
||
rmonUndersizePacketRising(1407),
|
||
rmonUndersizePacketRisingCleared(1408),
|
||
rmonFragmentRising(1409),
|
||
rmonFragmentRisingCleared(1410),
|
||
rmonDropEventRising(1411),
|
||
rmonDropEventRisingCleared(1412),
|
||
rmonCollisionRising(1413),
|
||
rmonCollisionRisingCleared(1414),
|
||
rmonIfInDiscardsRising(1415),
|
||
rmonIfInDiscardsRisingCleared(1416),
|
||
rmonIfInErrosRising(1417),
|
||
rmonIfInErrosRisingCleared(1418),
|
||
rmonIfOutDiscardsRising(1419),
|
||
rmonIfOutDiscardsRisingCleared(1420),
|
||
rmonIfOutErrosRising(1421),
|
||
rmonIfOutErrosRisingCleared(1422),
|
||
rmonIfInPauseFrameRising(1423),
|
||
rmonIfInPauseFrameRisingCleared(1424),
|
||
rmonIfOutPauseFrameRising(1425),
|
||
rmonIfOutPauseFrameRisingCleared(1426),
|
||
rmonQueueTransmitRising(1427),
|
||
rmonQueueTransmitRisingCleared(1428),
|
||
rmonQueueDropRising(1429),
|
||
rmonQueueDropRisingCleared(1430),
|
||
eponOltRedundancySwitchoverReasonSlotRemove(1500),
|
||
eponOltRedundancySwitchoverReasonSlotRestart(1501),
|
||
eponOltRedundancySwitchoverReasonAutoDetect(1502),
|
||
eponOltRedundancySwitchoverReasonWtrDetect(1503),
|
||
eponOnuCrcUpStreamAlarmErr(1504),
|
||
eponOnuCrcUpStreamAlarmErrClean(1505),
|
||
eponOnuTooFrequentlyRegisteredErr(1506),
|
||
eponOnuTooFrequentlyRegisteredErrClean(1507),
|
||
eponOnuCrcDownStreamAlarmErr(1508),
|
||
eponOnuCrcDownStreamAlarmErrClean(1509),
|
||
eponOnuOpticPowerAlarmErr(1510),
|
||
eponOnuOpticPowerAlarmErrClean(1511),
|
||
eponOnuDcVoltageAlarmErr(1512),
|
||
eponOnuDcVoltageAlarmErrClean(1513),
|
||
eponOnuLoopingAlarmErr(1514),
|
||
eponOnuLoopingAlarmErrClean(1515),
|
||
eponOltRedundancyStandbyOltRxPowerOverHighThresholdAlarm(1516),
|
||
eponOltRedundancyStandbyOltRxPowerUnderLowThresholdAlarm(1517),
|
||
eponOnuBroadcastStormLlidUpAlarmErr(1518),
|
||
eponOnuBroadcastStormLlidUpAlarmErrClean(1519),
|
||
eponOnuBroadcastStormLlidDnAlarmErr(1520),
|
||
eponOnuBroadcastStormLlidDnAlarmErrClean(1521),
|
||
eponOnuBroadcastStormUniUpAlarmErr(1522),
|
||
eponOnuBroadcastStormUniUpAlarmErrClean(1523),
|
||
eponDetectRogueOnuTurn(1530),
|
||
eponDetectRogueOnuTurnClean(1531),
|
||
eponOnuLoopDetectErr(1532),
|
||
eponOnuRecoverDetectErr(1533),
|
||
eponThresholdAlarmLoopDetectErr(1534),
|
||
eponThresholdAlarmRecoverLoopDetectErr(1535),
|
||
eponThresholdAlarmOpticAlarmErr(1536),
|
||
eponThresholdAlarmRecoverOpticAlarmErr(1537),
|
||
eponThresholdAlarmOverVoltageErr(1538),
|
||
eponThresholdAlarmRecoverOverVoltageErr(1539),
|
||
eponOLTSFPModuleInstalled(1540),
|
||
eponOLTSFPModuleRemoved(1541),
|
||
eponOnuDailyRxPowerAlarm(1542),
|
||
fiberLengthChangedWarningAlarm(1561),
|
||
fiberLengthChangedWarningAlarmCleared(1562),
|
||
cfmOnuMepRdiCcmDetected(1601),
|
||
cfmOnuMepRdiCcmCleared(1602),
|
||
cfmOnuMepMacStatusDetected(1603),
|
||
cfmOnuMepMacStatusCleared(1604),
|
||
cfmOnuMepRemoteCcmDetected(1605),
|
||
cfmOnuMepRemoteCcmCleared(1606),
|
||
cfmOnuMepErrorCcmDetected(1607),
|
||
cfmOnuMepErrprCcmCleared(1608),
|
||
cfmOnuMepXconCcmDetected(1609),
|
||
cfmOnuMepXconCcmCleared(1610),
|
||
cfmOnuMepUnexpectedPeriodDetected(1611),
|
||
cfmOnuMepUnexpectedPeriodCleared(1612),
|
||
cfmOnuMepAisDetected(1613),
|
||
cfmOnuMepAisCleared(1614),
|
||
tcpDosAttack(2001),
|
||
tcpDosAttackCleared(2002),
|
||
tcpPortFlooding(2003),
|
||
tcpPortFloodingCleared(2004),
|
||
tcpHostRandomFlooding(2005),
|
||
tcpHostRandomFloodingCleared(2006),
|
||
tcpHostScanning(2007),
|
||
tcpHostScanningCleared(2008),
|
||
ipSppfing(2009),
|
||
ipSppfingCleared(2010),
|
||
udpDosAttack(2011),
|
||
udpDosAttackCleared(2012),
|
||
udpPortFlooding(2013),
|
||
udpPortFloodingCleared(2014),
|
||
udpHostRandomFlooding(2015),
|
||
udpHostRandomFloodingCleared(2016),
|
||
udpHostScanning(2017),
|
||
udpHostScanningCleared(2018),
|
||
udpIPSppfing(2019),
|
||
udpIPSppfingCleared(2020),
|
||
icmpDosAttack(2021),
|
||
icmpDosAttackCleared(2022),
|
||
icmpIPSppfing(2023),
|
||
icmpIPSppfingCleared(2024),
|
||
icmpHostScanning(2025),
|
||
icmpHostScanningCleared(2026),
|
||
arpMacFlooding(2027),
|
||
arpMacFloodingCleared(2028),
|
||
arpSpoofing(2029),
|
||
arpSpoofingCleared(2030),
|
||
decoySnare(2031),
|
||
decoySnareCleared(2032),
|
||
hostScan(2033),
|
||
hostScanCleared(2034),
|
||
portScan(2035),
|
||
portScanCleared(2036),
|
||
tcpPortScanning(2037),
|
||
tcpPortScanningCleared(2038),
|
||
udpPortScanning(2039),
|
||
udpPortScanningCleared(2040),
|
||
staticAttack(2041),
|
||
staticAttackCleared(2042),
|
||
dmiTempHighOverDurationAlarm(2101),
|
||
dmiTempHighOverDurationAlarmCleared(2102),
|
||
dmiTempLowOverDurationAlarm(2103),
|
||
dmiTempLowOverDurationAlarmCleared(2104),
|
||
dmiTempHighOverDurationWarning(2105),
|
||
dmiTempHighOverDurationWarningCleared(2106),
|
||
dmiTempLowOverDurationWarning(2107),
|
||
dmiTempLowOverDurationWarningCleared(2108),
|
||
dmiVolHighOverDurationAlarm(2109),
|
||
dmiVolHighOverDurationAlarmCleared(2110),
|
||
dmiVolLowOverDurationAlarm(2111),
|
||
dmiVolLowOverDurationAlarmCleared(2112),
|
||
dmiVolHighOverDurationWarning(2113),
|
||
dmiVolHighOverDurationWarningCleared(2114),
|
||
dmiVolLowOverDurationWarning(2115),
|
||
dmiVolLowOverDurationWarningCleared(2116),
|
||
dmiTxBiasHighOverDurationAlarm(2117),
|
||
dmiTxBiasHighOverDurationAlarmCleared(2118),
|
||
dmiTxBiasLowOverDurationAlarm(2119),
|
||
dmiTxBiasLowOverDurationAlarmCleared(2120),
|
||
dmiTxBiasHighOverDurationWarning(2121),
|
||
dmiTxBiasHighOverDurationWarningCleared(2122),
|
||
dmiTxBiasLowOverDurationWarning(2123),
|
||
dmiTxBiasLowOverDurationWarningCleared(2124),
|
||
dmiTxPowerHighOverDurationAlarm(2125),
|
||
dmiTxPowerHighOverDurationAlarmCleared(2126),
|
||
dmiTxPowerLowOverDurationAlarm(2127),
|
||
dmiTxPowerLowOverDurationAlarmCleared(2128),
|
||
dmiTxPowerHighOverDurationWarning(2129),
|
||
dmiTxPowerHighOverDurationWarningCleared(2130),
|
||
dmiTxPowerLowOverDurationWarning(2131),
|
||
dmiTxPowerLowOverDurationWarningCleared(2132),
|
||
dmiRxPowerHighOverDurationAlarm(2133),
|
||
dmiRxPowerHighOverDurationAlarmCleared(2134),
|
||
dmiRxPowerLowOverDurationAlarm(2135),
|
||
dmiRxPowerLowOverDurationAlarmCleared(2136),
|
||
dmiRxPowerHighOverDurationWarning(2137),
|
||
dmiRxPowerHighOverDurationWarningCleared(2138),
|
||
dmiRxPowerLowOverDurationWarning(2139),
|
||
dmiRxPowerLowOverDurationWarningCleared(2140),
|
||
reloadMateInitiated(2201),
|
||
reloadMateDone(2202),
|
||
reloadSIUInitiated(2203),
|
||
reloadSIUDone(2204)
|
||
}
|
||
|
||
|
||
--
|
||
-- Node definitions
|
||
--
|
||
|
||
sleFaultMgmtBase OBJECT IDENTIFIER ::= { sleFaultMgmt 1 }
|
||
|
||
|
||
sleFaultMgmtBaseGroup OBJECT IDENTIFIER ::= { sleFaultMgmtBase 1 }
|
||
|
||
|
||
sleFaultDefaultSeverity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleFaultMgmtBaseGroup 1 }
|
||
|
||
|
||
sleFaultCriteriaSeverity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleFaultMgmtBaseGroup 2 }
|
||
|
||
|
||
sleFaultNotifiyActivity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disabled(0),
|
||
enabled(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleFaultMgmtBaseGroup 3 }
|
||
|
||
|
||
sleFaultNextSeqNum OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sequence number for the alarm synchronization.
|
||
This value has a number to be used for the next alarm trap."
|
||
::= { sleFaultMgmtBaseGroup 4 }
|
||
|
||
|
||
sleFaultMgmtBaseControl OBJECT IDENTIFIER ::= { sleFaultMgmtBase 2 }
|
||
|
||
|
||
sleFaultControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setAlarmDefaultSeverity(1),
|
||
setAlarmCriteriaSeverity(2),
|
||
setNotificationActivity(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" This attribute identifies the control commands.
|
||
updateAlarmList:
|
||
the NE updates entries of alarms in the sleAlarmListTable
|
||
after having changed alarm severities of alarms
|
||
(due to change profile pointers in
|
||
managed entities or after modification of alarm severities
|
||
in profiles). This command should be applied once after having
|
||
finisled modifications of severties.
|
||
modifyAlarmSeverity:
|
||
modifies the severity of an alarm in specific profile.
|
||
createAlarmSeverityProfile:
|
||
creates a new profile with default severities.
|
||
The severities then have to be modified with command changeAlarmSeverity.
|
||
deleteAlarmSeverityProfile:
|
||
deletes a profile. Profile 1 is not allowed to be deleted.
|
||
|
||
Notifications : none "
|
||
::= { sleFaultMgmtBaseControl 1 }
|
||
|
||
|
||
sleFaultControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleFaultMgmtBaseControl 2 }
|
||
|
||
|
||
sleFaultControlTimer OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleFaultMgmtBaseControl 3 }
|
||
|
||
|
||
sleFaultControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleFaultMgmtBaseControl 4 }
|
||
|
||
|
||
sleFaultControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleFaultMgmtBaseControl 5 }
|
||
|
||
|
||
sleFaultControlDefaultSeverity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleFaultMgmtBaseControl 6 }
|
||
|
||
|
||
sleFaultControlCriteriaSeverity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleFaultMgmtBaseControl 7 }
|
||
|
||
|
||
sleFaultControlNotifiyActivity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
diabled(0),
|
||
enabled(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleFaultMgmtBaseControl 8 }
|
||
|
||
|
||
sleFaultMgmtBaseNotification OBJECT IDENTIFIER ::= { sleFaultMgmtBase 3 }
|
||
|
||
|
||
sleAlarmDefaultSeverityChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultDefaultSeverity, sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMgmtBaseNotification 1 }
|
||
|
||
|
||
sleAlarmDefaultCriteriaChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultCriteriaSeverity, sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMgmtBaseNotification 2 }
|
||
|
||
|
||
sleNotificationActivityChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult, sleFaultNotifiyActivity }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMgmtBaseNotification 3 }
|
||
|
||
|
||
sleAlarmSeverity OBJECT IDENTIFIER ::= { sleFaultMgmt 2 }
|
||
|
||
|
||
sleAlarmSeverityTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAlarmSeverityEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The alarm severity table.
|
||
The alarm severity table associates
|
||
profile index and AlarmID pairs with severities to be
|
||
used for alarm traps.
|
||
(Note that this table does not apply to cleared alarms). "
|
||
::= { sleAlarmSeverity 1 }
|
||
|
||
|
||
sleAlarmSeverityEntry OBJECT-TYPE
|
||
SYNTAX SleAlarmSeverityEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Entry of the alarm severity table. "
|
||
INDEX { sleAlarmSeverityIndex }
|
||
::= { sleAlarmSeverityTable 1 }
|
||
|
||
|
||
SleAlarmSeverityEntry ::=
|
||
SEQUENCE {
|
||
sleAlarmSeverityIndex
|
||
SpecificNum,
|
||
sleAlarmSeverityValue
|
||
INTEGER
|
||
}
|
||
|
||
sleAlarmSeverityIndex OBJECT-TYPE
|
||
SYNTAX SpecificNum
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following alarms is devided by the specific character, ===============.
|
||
The division basis is that alarms is bounded or released.
|
||
|
||
001: portDown: To detect whether physical or logical interface's link status is up or down.
|
||
002: portUp:
|
||
===============
|
||
003: portRemoved: To detect whether physical interface is installed or not.
|
||
004: portInstalled:
|
||
===============
|
||
005: powerFail: To detect whether power module's operation status is good or not.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
006: powerOK:
|
||
===============
|
||
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
008: powerInstalled:
|
||
===============
|
||
009: fanFail: To detect whether FAN module's operation status is good or not.
|
||
010: fanOK:
|
||
===============
|
||
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
|
||
012: fanInstalled:
|
||
===============
|
||
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
|
||
014: moduleInstalled:
|
||
===============
|
||
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
|
||
===============
|
||
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
|
||
(This alarm isn<73><6E>t used current)
|
||
===============
|
||
017: broadcastOver: To detect the receipt of broadcast packet.
|
||
(This alarm isn<73><6E>t used current)
|
||
018: broadcastUnder:
|
||
===============
|
||
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
|
||
020: cpuUnderLoad:
|
||
===============
|
||
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
|
||
022: memoryUnderUsed:
|
||
===============
|
||
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
|
||
less than delta value of current interface's InOctects or not.
|
||
024: portUnderThreshold:
|
||
===============
|
||
025: temperatureHigh: To detect whether the configured system's temperature threshold is
|
||
less than current temperature or not.
|
||
026: temperatureLow:
|
||
===============
|
||
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
|
||
028: mfgdReleased:
|
||
===============
|
||
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
|
||
030: ipUnconflict:
|
||
===============
|
||
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
|
||
sufficient or not.
|
||
032: dhcpLeaseSufficient:
|
||
===============
|
||
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
|
||
034: dhcpRemovedIllegalEntry:
|
||
===============
|
||
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not. But alarm generation
|
||
would be issued by means of event type in RMON event.
|
||
036: rmonAlarmNoRising:
|
||
===============
|
||
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not.
|
||
But alarm generation would be issued by means of event type in RMON event.
|
||
038: rmonAlarmNoFalling:
|
||
===============
|
||
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
|
||
So STP reconfiguration doesn't use this edge ports.
|
||
===============
|
||
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So, Root guard prevents a new inserted node from being root bridge as well as
|
||
receiving a superior BPDU from root bridge.
|
||
but this node participates in STP topology reconfiguration.
|
||
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
|
||
===============
|
||
041: portSecurity: To detect whether interface is configured for security or not.
|
||
This can be used to prevent MAC from flooding as well as spoofing.
|
||
That is, As a result, this will obstruct an attack as like DoS attack.
|
||
===============
|
||
042: userLogin:
|
||
043: userLogout:
|
||
===============
|
||
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
|
||
052: igmpGroupLeaved:
|
||
===============
|
||
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
|
||
054: dhcpIpaddressFree:
|
||
===============
|
||
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
|
||
056: doorClosed:
|
||
===============
|
||
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
|
||
A system is using AC power usually.
|
||
If there is any power problems as like a power failure,
|
||
a system is using battery instead of AC power.
|
||
058: powerModeChangedBatteryToPower:
|
||
===============
|
||
059: batterylowcapacity: To detect whether current battery capacity is less
|
||
capacity threshold according to battery usage or not.
|
||
The capacity of AC power is 16 voltage and battery is 20.
|
||
Capacity threshold is configured by H/W specification.
|
||
So operator can't change it.
|
||
060: batterynormalcapacity:
|
||
===============
|
||
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
|
||
062: batterynormalTemperature:
|
||
===============
|
||
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
|
||
064: authenticationNofail:
|
||
===============
|
||
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
|
||
greater than temperature threshold or not.
|
||
066: psuAcNormalTemperature:
|
||
===============
|
||
067: batteryRemoved: To detect whether battery is equipped at network system or not.
|
||
Battery is used as redundancy power service. So operator can decide the installation of battery.
|
||
068: batteryEquipped:
|
||
===============
|
||
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
|
||
12.5 volt value is configured by H/W specification. So operator can't change it.
|
||
070: batteryNormalVoltage:
|
||
===============
|
||
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
|
||
072: adminAccessLogout:
|
||
===============
|
||
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
|
||
074: cfgdReleased:
|
||
===============
|
||
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
|
||
076: sfgdReleased:
|
||
===============
|
||
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
|
||
078: swWatchdogNormalState:
|
||
===============
|
||
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
|
||
080: swWatchdogClearError:
|
||
===============
|
||
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
|
||
082: ppsControlReleased:
|
||
===============
|
||
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
|
||
084: gotDMITempHighFallAlarm:
|
||
===============
|
||
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
|
||
086: gotDMITempLowFallAlarm:
|
||
===============
|
||
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
|
||
088: gotDMITempHighFallWarning:
|
||
===============
|
||
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
|
||
090: gotDMITempLowFallWarning:
|
||
===============
|
||
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
|
||
092: gotDMIVolHighFallAlarm:
|
||
===============
|
||
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
|
||
094: gotDMIVolLowFallAlarm:
|
||
===============
|
||
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
|
||
096: gotDMIVolHighFallWarning:
|
||
===============
|
||
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
|
||
098: gotDMIVolLowFallWarning:
|
||
===============
|
||
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
|
||
100: gotDMITxBiasHighFallAlarm:
|
||
===============
|
||
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
|
||
102: gotDMITxBiasLowFallAlarm:
|
||
===============
|
||
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
|
||
104: gotDMITxBiasHighFallWarning:
|
||
===============
|
||
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
|
||
106: gotDMITxBiasLowFallWarning:
|
||
===============
|
||
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
|
||
108: gotDMITxPowerHighFallAlarm:
|
||
===============
|
||
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
|
||
110: gotDMITxPowerLowFallAlarm:
|
||
===============
|
||
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
|
||
112: gotDMITxPowerHighFallWarning:
|
||
===============
|
||
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
|
||
114: gotDMITxPowerLowFallWarning:
|
||
===============
|
||
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
|
||
116: gotDMIRxPowerHighFallAlarm:
|
||
===============
|
||
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
|
||
118: gotDMIRxPowerLowFallAlarm:
|
||
===============
|
||
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
|
||
120: gotDMIRxPowerHighFallWarning:
|
||
===============
|
||
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
|
||
122: gotDMIRxPowerLowFallWarning:
|
||
===============
|
||
123: nosRemoteUpgradeRequest:
|
||
124: nosRemoteUpgradeSuccess:
|
||
125: nosRemoteUpgradeFailAbort:
|
||
126: nosRemoteUpgradeFailHeaderError:
|
||
127: nosRemoteUpgradeFailDownloadError:
|
||
128: nosRemoteUpgradeFailFlashError:
|
||
129: nosRemoteUpgradeStart:
|
||
===============
|
||
130: systemDyingGasp:
|
||
===============
|
||
133: cliHistory: To detect whether CLI history is detected or not.
|
||
134: cliHistoryNo:
|
||
===============
|
||
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
|
||
136: ntpConnectionFailNo:
|
||
===============
|
||
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
|
||
===============
|
||
159: clockModuleRemoved: To detect whether clock module is removed or installed.
|
||
160: clockModuleInstalled:
|
||
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
|
||
162: clockModuleInitOk:
|
||
===============
|
||
163: cliHistoryLog: To detect whether CLI history log is over or not.
|
||
164: cliHistoryLogNo:
|
||
===============
|
||
165: slotActionEvent: To detect whether slot action is changed.
|
||
166: slotStateChange: To detect whether slot state is changed.
|
||
===============
|
||
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
|
||
168: interfaceAdminUp:
|
||
===============
|
||
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
|
||
170: slotPowerMonNormal:
|
||
===============
|
||
171: slotErrorLEDChanged: To detect whether error LED is changed.
|
||
===============
|
||
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
|
||
186: cpuPpsUnderThreshold:
|
||
===============
|
||
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
|
||
200: slotHealthStatusTimeoutCleared:
|
||
===============
|
||
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
|
||
202: advaTemperatureNo:
|
||
===============
|
||
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
|
||
204: advaPSUFailureNo:
|
||
===============
|
||
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
|
||
206: advaFanFailureNo:
|
||
===============
|
||
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
|
||
208: advaInterfaceReceiveFailureNo:
|
||
===============
|
||
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
|
||
less than optical threshold or not.
|
||
210: advaInterfaceOpticalThresholdNo:
|
||
===============
|
||
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
|
||
212: advaInterfaceTransmitFaultNo:
|
||
===============
|
||
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
|
||
214: advaInterfaceMisconfigurationNo:
|
||
===============
|
||
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
|
||
216: advaInterfaceSFPMismatchNo:
|
||
===============
|
||
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
|
||
218: advaVoltageLowNo:
|
||
===============
|
||
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
|
||
220: advaVoltageHighNo:
|
||
===============
|
||
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a node does not receive
|
||
any test packet at any of its ports for a period of 3 times.
|
||
302: erpDomainLotpNo:
|
||
===============
|
||
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a RM node of one domain does not
|
||
receive any test packet at one port for a period of 3 times.
|
||
304: erpDomainULotpNo:
|
||
===============
|
||
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
|
||
The defect is raised when a RM node receives its own test packets
|
||
with an Ack destination address field with a non-zero value.
|
||
306: erpDomainMultipleRMNo:
|
||
===============
|
||
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
|
||
The detection of multiple failures indicates that the ring is segmented and
|
||
that the RM Node is unreacheable.
|
||
This is only possible at normal ring nodes isolated from the RM node.
|
||
308: erpDomainRMNodeReacheablityNo:
|
||
===============
|
||
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
|
||
===============
|
||
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
|
||
That is, ONU that its operation is service on should be sent registration information to OLT.
|
||
402: eponOnuRegister:
|
||
===============
|
||
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
|
||
404: eponOnuNoRegistrationError:
|
||
===============
|
||
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
|
||
A message between ONU and OLT is encrypted using random encryption key.
|
||
There is that the encryption key is invalid as transmission failure from time to time.
|
||
406: eponNoBadEncryptionKey:
|
||
===============
|
||
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
|
||
On registering, ONU informs unique ID to OLT.
|
||
And then, all communication between ONU and OLT must use the unique ID.
|
||
The unique ID is called Llid.
|
||
408: eponNoLlidMismatch:
|
||
===============
|
||
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
|
||
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
|
||
410: eponNoTooManyRegister:
|
||
===============
|
||
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
|
||
A ONU could be changed to down state as a number of reasons.
|
||
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
|
||
then ONU's link would be changed to down.
|
||
412: eponNoDyingGASP:
|
||
===============
|
||
413: eponOnuErrFramePeriod:
|
||
414: eponOnuNoErrFramePeriod:
|
||
===============
|
||
415: eponOnuErrFrame:
|
||
416: eponOnuNoErrFrame:
|
||
===============
|
||
417: eponOnuErrFrameSecondSummary:
|
||
418: eponOnuNoErrFrameSecondSummary:
|
||
===============
|
||
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
|
||
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
|
||
420: eponOnuNoLastOnuDeregister:
|
||
===============
|
||
421: eponOltCableDown:
|
||
422: eponOltRecoverCableDown:
|
||
===============
|
||
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
|
||
502: autoCLINoStart:
|
||
===============
|
||
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
|
||
504: autoCLINoComplete:
|
||
===============
|
||
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
|
||
The reason that the result file is removed is that the configured file size for the result is
|
||
less than the stored result file size.
|
||
If so, the oldest file would be removed before everything.
|
||
506: autoCLINoRemoveOutputFile:
|
||
===============
|
||
507: autoResetSystem: To detect whether the system is restarted or not.
|
||
The conditions that system is restarted is that ping loss threshold is
|
||
less than current ping loss count during the configured interval and
|
||
that current free memory size is less than configured free memory size.
|
||
508: autoResetNoSystem:
|
||
===============
|
||
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
|
||
Operator designates any gateway system that can communicate to detect
|
||
current network environment.
|
||
System sends ICMP packet to the designated gateway system periodically.
|
||
If the system doesn't receive ping reply packet within any interval,
|
||
operator recognizes that the system can't communicate any more
|
||
because of some problems of the system.
|
||
510: autoResetNoPingReplyLoss:
|
||
===============
|
||
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
|
||
less than the configured free memory size or not.
|
||
Periodically, free memory size is checked to confirm system availability.
|
||
512: autoResetNoMemoryLeakDetect:
|
||
===============
|
||
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
|
||
602: arulePacketDropRelease:
|
||
===============
|
||
620: bME1CardNoDetect:
|
||
621: clearBME1CardNoDetect:
|
||
===============
|
||
622: bME1CardAFEerror:
|
||
623: clearBME1CardAFEerror:
|
||
===============
|
||
624: bME1CardIFEerror:
|
||
625: clearBME1CardIFEerror:
|
||
===============
|
||
626: bME1CardFWerror:
|
||
627: clearBME1CardFWerror:
|
||
===============
|
||
628: bME1CardPROVerror:
|
||
629: clearBME1CardPROVerror:
|
||
===============
|
||
630: bME1CrashDetect:
|
||
631: clearBME1CrashDetect:
|
||
===============
|
||
632: bME2CardNoDetect:
|
||
633: clearBME2CardNoDetect:
|
||
===============
|
||
634: bME2CardAFEerror:
|
||
635: clearBME2CardAFEerror:
|
||
===============
|
||
636: bME2CardIFEerror:
|
||
637: clearBME2CardIFEerror:
|
||
===============
|
||
638: bME2CardFWerror:
|
||
639: clearBME2CardFWerror:
|
||
===============
|
||
640: bME2CardPROVerror:
|
||
641: clearBME2CardPROVerror:
|
||
===============
|
||
642: bME2CrashDetect:
|
||
643: clearBME2CrashDetect:
|
||
===============
|
||
644: bME3CardNoDetect:
|
||
645: clearBME3CardNoDetect:
|
||
===============
|
||
646: bME3CardAFEerror:
|
||
647: clearBME3CardAFEerror:
|
||
===============
|
||
648: bME3CardIFEerror:
|
||
649: clearBME3CardIFEerror:
|
||
===============
|
||
650: bME3CardFWerror:
|
||
651: clearBME3CardFWerror:
|
||
===============
|
||
652: bME3CardPROVerror:
|
||
653: clearBME3CardPROVerror:
|
||
===============
|
||
654: bME3CrashDetect:
|
||
655: clearBME3CrashDetect:
|
||
===============
|
||
656: powerFromBattery:
|
||
657: clearPowerFromBattery:
|
||
===============
|
||
658: invalidBatteryStatus:
|
||
659: clearInvalidBatteryStatus:
|
||
===============
|
||
660: batteryChargeLow:
|
||
661: clearBatteryChargeLow:
|
||
===============
|
||
662: batteryNotPresent:
|
||
663: clearBatteryNotPresent:
|
||
===============
|
||
664: voltageLow:
|
||
665: clearVoltageLow:
|
||
===============
|
||
666: tempOverThreshold:
|
||
667: clearTempOverThreshold:
|
||
===============
|
||
668: tempUnderThreshold:
|
||
669: clearTempUnderThreshold:
|
||
===============
|
||
670: cpuOverThreshold:
|
||
671: clearCpuOverThreshold:
|
||
===============
|
||
672: trafficOverload:
|
||
673: clearTrafficOverload:
|
||
===============
|
||
674: gEPONModuleNotDetect:
|
||
675: clearGEPONModuleNotDetect:
|
||
===============
|
||
676: gEPONPortOperationDown:
|
||
677: clearGEPONPortOperationDown:
|
||
===============
|
||
678: gEPONNoIncomingTraffic:
|
||
679: clearGEPONNoIncomingTraffic:
|
||
===============
|
||
680: processCrashDetect:
|
||
681: clearProcessCrashDetect:
|
||
===============
|
||
682: memoryLeakDetect:
|
||
683: clearMemoryLeakDetect:
|
||
===============
|
||
684: memoryCorrupDetect:
|
||
685: clearMemoryCorrupDetect:
|
||
===============
|
||
686: memoryLowDetect:
|
||
687: clearMemoryLowDetect:
|
||
===============
|
||
688: dataLineerror:
|
||
689: clearDataLineerror:
|
||
===============
|
||
690: addressLineerror:
|
||
691: clearAddressLineerror:
|
||
===============
|
||
692: chipsetNotDetcet:
|
||
693: clearChipsetNotDetcet:
|
||
===============
|
||
694: pciBuserror:
|
||
695: clearPciBuserror:
|
||
===============
|
||
696: securityAdminConnect:
|
||
697: clearSecurityAdminConnect:
|
||
===============
|
||
698: oNUPowerDown:
|
||
699: clearONUPowerDown:
|
||
===============
|
||
700: oNUNotRegister:
|
||
701: clearONUNotRegister:
|
||
===============
|
||
702: oNTOpticPre:
|
||
703: clearONTOpticPre:
|
||
===============
|
||
800: switchoverInitiated:
|
||
===============
|
||
801: switchoverDone:
|
||
===============
|
||
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
|
||
===============
|
||
901: gponNoAuthCBU: To detect no auth CBU is detected.
|
||
902: gponDuplicateONU: To detect ONU is duplicated.
|
||
903: gponDyingGasp: To detect dying GASP is detected.
|
||
904: gponUpgradeComplete: To detect upgrade complete is detected.
|
||
905: gponDeregistered: To detect whether deregistered is detected or not.
|
||
906: gponRegistered:
|
||
907: gponRogueOnu: To detect rogue ONU is detected
|
||
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
|
||
909: clearGponOnuBetteryEvent:
|
||
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
|
||
911: gponTransceiverChanged: To detect transceiver is changed.
|
||
912: gponOltLosOn: To detect whether OLT LOS is on or off
|
||
913: gponOltLosOff:
|
||
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
|
||
915: gponOltLosiOff:
|
||
916: gponDyingGaspOn: To detect whether dying GASP is on or off
|
||
917: gponDyingGaspOff:
|
||
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
|
||
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
|
||
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
|
||
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
|
||
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
|
||
923: gponOnuTemperatureHighFallThreshold:
|
||
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
|
||
925: gponOnuTemperatureLowFallThreshold:
|
||
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
|
||
927: gponOnuCpuFallThreshold:
|
||
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
|
||
929: gponOnuMemoryFallThreshold:
|
||
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
|
||
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
|
||
932: gponOnuRxOpticLowThreshAlarmOff:
|
||
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
|
||
934: gponOnuRxOpticHighThreshAlarmOff:
|
||
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
|
||
936: gponOltLOFIOff:
|
||
937: gponOltDOWOn: To detect whether OLT DOW is on or off
|
||
938: gponOltDOWOff:
|
||
939: gponOltSFOn: To detect whether OLT SF is on or off
|
||
940: gponOltSFOff:
|
||
941: gponOltSDOn: To detect whether OLT SD is on or off
|
||
942: gponOltSDOff:
|
||
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
|
||
944: gponOltLCDGIOff:
|
||
945: gponOltRDOn: To detect whether OLT RD is on or off
|
||
946: gponOltRDOff:
|
||
947: gponOltSUFOn: To detect whether OLT SUF is on or off
|
||
948: gponOltSUFOff:
|
||
949: gponOltLOAOn: To detect whether OLT LOA is on or off
|
||
950: gponOltLOAOff:
|
||
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
|
||
952: gponOltLOAMIOff:
|
||
953: gponOltMEMOn: To detect whether OLT MEM is on or off
|
||
954: gponOltMEMOff:
|
||
955: gponOltPEEOn: To detect whether OLT PEE is on or off
|
||
956: gponOltPEEOff:
|
||
957: gponOltPSTOn: To detect whether OLT PST is on or off
|
||
958: gponOltPSTOff:
|
||
959: gponOltERROn: To detect whether OLT ERR is on or off
|
||
960: gponOltERROff:
|
||
961: gponOltREIOn: To detect whether OLT REI is on or off
|
||
962: gponOltREIOff:
|
||
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
|
||
964: gponAntiSpoofingDupPortOff:
|
||
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
|
||
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
|
||
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
|
||
968: gponOnuPortOpticModuleInstall:
|
||
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
|
||
970: gponOnuOMCCProblemCleared:
|
||
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
|
||
972: gponOltFixedTcontAlarmOff:
|
||
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
|
||
974: gponOltDynamicTcontAlarmOff:
|
||
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
|
||
976: gponOltPortCountAlarmOff:
|
||
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
|
||
978: gponOltCableDownAlarmOff:
|
||
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
|
||
980: gponOltDeactiveMonitorAlarmOff:
|
||
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
|
||
982: gponOltDfiOff:
|
||
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
|
||
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
|
||
986: gponOnuPortOperStatusUp::
|
||
===============
|
||
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
|
||
1102: emLogDefectCPUHighUnder:
|
||
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
|
||
1104: emLogTemperHighUnder:
|
||
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
|
||
1106: emLogTemperLowOver:
|
||
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
|
||
1108: emLogMemLowOver:
|
||
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
|
||
1110: emLogFanFailCleared:
|
||
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
|
||
1112: emLogPhyCRCFailCleared:
|
||
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
|
||
1114: emLogPhyDetectFailCleared:
|
||
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
|
||
1116: emLogSFUMateInitFailCleared:
|
||
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
|
||
1118: emLogDaemonHealthBadCleared:
|
||
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
|
||
1120: emLogGPIURavenLinkDownCleared:
|
||
===============
|
||
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
|
||
1152: slotNosUpgradeEnd:
|
||
===============
|
||
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
|
||
1332: gponOnuAniVoltageLowThreshAlarmOff:
|
||
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
|
||
1334: gponOnuAniVoltageHighThreshAlarmOff:
|
||
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
|
||
1336: gponOnuAniTemperatureLowThreshAlarmOff:
|
||
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
|
||
1338: gponOnuAniTemperatureHighThreshAlarmOff:
|
||
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
|
||
1340: gponOnuAniTxBiasLowThreshAlarmOff:
|
||
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
|
||
1342: gponOnuAniTxBiasHighThreshAlarmOff:
|
||
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
|
||
1344: gponOnuAniTxpowerLowThreshAlarmOff:
|
||
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
|
||
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
|
||
::= { sleAlarmSeverityEntry 1 }
|
||
|
||
|
||
sleAlarmSeverityValue OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleAlarmSeverityEntry 2 }
|
||
|
||
|
||
sleAlarmSeverityControl OBJECT IDENTIFIER ::= { sleAlarmSeverity 2 }
|
||
|
||
|
||
sleAlarmSeverityControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createAlarmSeveriity(1),
|
||
destroyAlarmSeveriity(2),
|
||
setAlarmSeveriity(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" This attribute identifies the control commands.
|
||
updateAlarmList:
|
||
the NE updates entries of alarms in the sleAlarmListTable
|
||
after having changed alarm severities of alarms
|
||
(due to change profile pointers in
|
||
managed entities or after modification of alarm severities
|
||
in profiles). This command should be applied once after having
|
||
finisled modifications of severties.
|
||
modifyAlarmSeverity:
|
||
modifies the severity of an alarm in specific profile.
|
||
createAlarmSeverityProfile:
|
||
creates a new profile with default severities.
|
||
The severities then have to be modified with command changeAlarmSeverity.
|
||
deleteAlarmSeverityProfile:
|
||
deletes a profile. Profile 1 is not allowed to be deleted.
|
||
|
||
Notifications : none "
|
||
::= { sleAlarmSeverityControl 1 }
|
||
|
||
|
||
sleAlarmSeverityControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleAlarmSeverityControl 2 }
|
||
|
||
|
||
sleAlarmSeverityControlTimer OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleAlarmSeverityControl 3 }
|
||
|
||
|
||
sleAlarmSeverityControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleAlarmSeverityControl 4 }
|
||
|
||
|
||
sleAlarmSeverityControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleAlarmSeverityControl 5 }
|
||
|
||
|
||
sleAlarmSeverityControlIndex OBJECT-TYPE
|
||
SYNTAX SpecificNum
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" A number identifying this alarm severity profile.
|
||
The following alarms is devided by the specific character, ===============.
|
||
The division basis is that alarms is bounded or released.
|
||
|
||
001: portDown: To detect whether physical or logical interface's link status is up or down.
|
||
002: portUp:
|
||
===============
|
||
003: portRemoved: To detect whether physical interface is installed or not.
|
||
004: portInstalled:
|
||
===============
|
||
005: powerFail: To detect whether power module's operation status is good or not.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
006: powerOK:
|
||
===============
|
||
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
008: powerInstalled:
|
||
===============
|
||
009: fanFail: To detect whether FAN module's operation status is good or not.
|
||
010: fanOK:
|
||
===============
|
||
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
|
||
012: fanInstalled:
|
||
===============
|
||
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
|
||
014: moduleInstalled:
|
||
===============
|
||
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
|
||
===============
|
||
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
|
||
(This alarm isn<73><6E>t used current)
|
||
===============
|
||
017: broadcastOver: To detect the receipt of broadcast packet.
|
||
(This alarm isn<73><6E>t used current)
|
||
018: broadcastUnder:
|
||
===============
|
||
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
|
||
020: cpuUnderLoad:
|
||
===============
|
||
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
|
||
022: memoryUnderUsed:
|
||
===============
|
||
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
|
||
less than delta value of current interface's InOctects or not.
|
||
024: portUnderThreshold:
|
||
===============
|
||
025: temperatureHigh: To detect whether the configured system's temperature threshold is
|
||
less than current temperature or not.
|
||
026: temperatureLow:
|
||
===============
|
||
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
|
||
028: mfgdReleased:
|
||
===============
|
||
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
|
||
030: ipUnconflict:
|
||
===============
|
||
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
|
||
sufficient or not.
|
||
032: dhcpLeaseSufficient:
|
||
===============
|
||
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
|
||
034: dhcpRemovedIllegalEntry:
|
||
===============
|
||
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not. But alarm generation
|
||
would be issued by means of event type in RMON event.
|
||
036: rmonAlarmNoRising:
|
||
===============
|
||
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not.
|
||
But alarm generation would be issued by means of event type in RMON event.
|
||
038: rmonAlarmNoFalling:
|
||
===============
|
||
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
|
||
So STP reconfiguration doesn't use this edge ports.
|
||
===============
|
||
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So, Root guard prevents a new inserted node from being root bridge as well as
|
||
receiving a superior BPDU from root bridge.
|
||
but this node participates in STP topology reconfiguration.
|
||
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
|
||
===============
|
||
041: portSecurity: To detect whether interface is configured for security or not.
|
||
This can be used to prevent MAC from flooding as well as spoofing.
|
||
That is, As a result, this will obstruct an attack as like DoS attack.
|
||
===============
|
||
042: userLogin:
|
||
043: userLogout:
|
||
===============
|
||
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
|
||
052: igmpGroupLeaved:
|
||
===============
|
||
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
|
||
054: dhcpIpaddressFree:
|
||
===============
|
||
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
|
||
056: doorClosed:
|
||
===============
|
||
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
|
||
A system is using AC power usually.
|
||
If there is any power problems as like a power failure,
|
||
a system is using battery instead of AC power.
|
||
058: powerModeChangedBatteryToPower:
|
||
===============
|
||
059: batterylowcapacity: To detect whether current battery capacity is less
|
||
capacity threshold according to battery usage or not.
|
||
The capacity of AC power is 16 voltage and battery is 20.
|
||
Capacity threshold is configured by H/W specification.
|
||
So operator can't change it.
|
||
060: batterynormalcapacity:
|
||
===============
|
||
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
|
||
062: batterynormalTemperature:
|
||
===============
|
||
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
|
||
064: authenticationNofail:
|
||
===============
|
||
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
|
||
greater than temperature threshold or not.
|
||
066: psuAcNormalTemperature:
|
||
===============
|
||
067: batteryRemoved: To detect whether battery is equipped at network system or not.
|
||
Battery is used as redundancy power service. So operator can decide the installation of battery.
|
||
068: batteryEquipped:
|
||
===============
|
||
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
|
||
12.5 volt value is configured by H/W specification. So operator can't change it.
|
||
070: batteryNormalVoltage:
|
||
===============
|
||
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
|
||
072: adminAccessLogout:
|
||
===============
|
||
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
|
||
074: cfgdReleased:
|
||
===============
|
||
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
|
||
076: sfgdReleased:
|
||
===============
|
||
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
|
||
078: swWatchdogNormalState:
|
||
===============
|
||
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
|
||
080: swWatchdogClearError:
|
||
===============
|
||
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
|
||
082: ppsControlReleased:
|
||
===============
|
||
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
|
||
084: gotDMITempHighFallAlarm:
|
||
===============
|
||
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
|
||
086: gotDMITempLowFallAlarm:
|
||
===============
|
||
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
|
||
088: gotDMITempHighFallWarning:
|
||
===============
|
||
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
|
||
090: gotDMITempLowFallWarning:
|
||
===============
|
||
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
|
||
092: gotDMIVolHighFallAlarm:
|
||
===============
|
||
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
|
||
094: gotDMIVolLowFallAlarm:
|
||
===============
|
||
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
|
||
096: gotDMIVolHighFallWarning:
|
||
===============
|
||
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
|
||
098: gotDMIVolLowFallWarning:
|
||
===============
|
||
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
|
||
100: gotDMITxBiasHighFallAlarm:
|
||
===============
|
||
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
|
||
102: gotDMITxBiasLowFallAlarm:
|
||
===============
|
||
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
|
||
104: gotDMITxBiasHighFallWarning:
|
||
===============
|
||
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
|
||
106: gotDMITxBiasLowFallWarning:
|
||
===============
|
||
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
|
||
108: gotDMITxPowerHighFallAlarm:
|
||
===============
|
||
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
|
||
110: gotDMITxPowerLowFallAlarm:
|
||
===============
|
||
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
|
||
112: gotDMITxPowerHighFallWarning:
|
||
===============
|
||
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
|
||
114: gotDMITxPowerLowFallWarning:
|
||
===============
|
||
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
|
||
116: gotDMIRxPowerHighFallAlarm:
|
||
===============
|
||
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
|
||
118: gotDMIRxPowerLowFallAlarm:
|
||
===============
|
||
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
|
||
120: gotDMIRxPowerHighFallWarning:
|
||
===============
|
||
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
|
||
122: gotDMIRxPowerLowFallWarning:
|
||
===============
|
||
123: nosRemoteUpgradeRequest:
|
||
124: nosRemoteUpgradeSuccess:
|
||
125: nosRemoteUpgradeFailAbort:
|
||
126: nosRemoteUpgradeFailHeaderError:
|
||
127: nosRemoteUpgradeFailDownloadError:
|
||
128: nosRemoteUpgradeFailFlashError:
|
||
129: nosRemoteUpgradeStart:
|
||
===============
|
||
130: systemDyingGasp:
|
||
===============
|
||
133: cliHistory: To detect whether CLI history is detected or not.
|
||
134: cliHistoryNo:
|
||
===============
|
||
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
|
||
136: ntpConnectionFailNo:
|
||
===============
|
||
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
|
||
===============
|
||
159: clockModuleRemoved: To detect whether clock module is removed or installed.
|
||
160: clockModuleInstalled:
|
||
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
|
||
162: clockModuleInitOk:
|
||
===============
|
||
163: cliHistoryLog: To detect whether CLI history log is over or not.
|
||
164: cliHistoryLogNo:
|
||
===============
|
||
165: slotActionEvent: To detect whether slot action is changed.
|
||
166: slotStateChange: To detect whether slot state is changed.
|
||
===============
|
||
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
|
||
168: interfaceAdminUp:
|
||
===============
|
||
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
|
||
170: slotPowerMonNormal:
|
||
===============
|
||
171: slotErrorLEDChanged: To detect whether error LED is changed.
|
||
===============
|
||
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
|
||
186: cpuPpsUnderThreshold:
|
||
===============
|
||
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
|
||
200: slotHealthStatusTimeoutCleared:
|
||
===============
|
||
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
|
||
202: advaTemperatureNo:
|
||
===============
|
||
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
|
||
204: advaPSUFailureNo:
|
||
===============
|
||
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
|
||
206: advaFanFailureNo:
|
||
===============
|
||
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
|
||
208: advaInterfaceReceiveFailureNo:
|
||
===============
|
||
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
|
||
less than optical threshold or not.
|
||
210: advaInterfaceOpticalThresholdNo:
|
||
===============
|
||
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
|
||
212: advaInterfaceTransmitFaultNo:
|
||
===============
|
||
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
|
||
214: advaInterfaceMisconfigurationNo:
|
||
===============
|
||
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
|
||
216: advaInterfaceSFPMismatchNo:
|
||
===============
|
||
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
|
||
218: advaVoltageLowNo:
|
||
===============
|
||
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
|
||
220: advaVoltageHighNo:
|
||
===============
|
||
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a node does not receive
|
||
any test packet at any of its ports for a period of 3 times.
|
||
302: erpDomainLotpNo:
|
||
===============
|
||
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a RM node of one domain does not
|
||
receive any test packet at one port for a period of 3 times.
|
||
304: erpDomainULotpNo:
|
||
===============
|
||
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
|
||
The defect is raised when a RM node receives its own test packets
|
||
with an Ack destination address field with a non-zero value.
|
||
306: erpDomainMultipleRMNo:
|
||
===============
|
||
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
|
||
The detection of multiple failures indicates that the ring is segmented and
|
||
that the RM Node is unreacheable.
|
||
This is only possible at normal ring nodes isolated from the RM node.
|
||
308: erpDomainRMNodeReacheablityNo:
|
||
===============
|
||
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
|
||
===============
|
||
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
|
||
That is, ONU that its operation is service on should be sent registration information to OLT.
|
||
402: eponOnuRegister:
|
||
===============
|
||
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
|
||
404: eponOnuNoRegistrationError:
|
||
===============
|
||
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
|
||
A message between ONU and OLT is encrypted using random encryption key.
|
||
There is that the encryption key is invalid as transmission failure from time to time.
|
||
406: eponNoBadEncryptionKey:
|
||
===============
|
||
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
|
||
On registering, ONU informs unique ID to OLT.
|
||
And then, all communication between ONU and OLT must use the unique ID.
|
||
The unique ID is called Llid.
|
||
408: eponNoLlidMismatch:
|
||
===============
|
||
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
|
||
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
|
||
410: eponNoTooManyRegister:
|
||
===============
|
||
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
|
||
A ONU could be changed to down state as a number of reasons.
|
||
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
|
||
then ONU's link would be changed to down.
|
||
412: eponNoDyingGASP:
|
||
===============
|
||
413: eponOnuErrFramePeriod:
|
||
414: eponOnuNoErrFramePeriod:
|
||
===============
|
||
415: eponOnuErrFrame:
|
||
416: eponOnuNoErrFrame:
|
||
===============
|
||
417: eponOnuErrFrameSecondSummary:
|
||
418: eponOnuNoErrFrameSecondSummary:
|
||
===============
|
||
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
|
||
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
|
||
420: eponOnuNoLastOnuDeregister:
|
||
===============
|
||
421: eponOltCableDown:
|
||
422: eponOltRecoverCableDown:
|
||
===============
|
||
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
|
||
502: autoCLINoStart:
|
||
===============
|
||
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
|
||
504: autoCLINoComplete:
|
||
===============
|
||
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
|
||
The reason that the result file is removed is that the configured file size for the result is
|
||
less than the stored result file size.
|
||
If so, the oldest file would be removed before everything.
|
||
506: autoCLINoRemoveOutputFile:
|
||
===============
|
||
507: autoResetSystem: To detect whether the system is restarted or not.
|
||
The conditions that system is restarted is that ping loss threshold is
|
||
less than current ping loss count during the configured interval and
|
||
that current free memory size is less than configured free memory size.
|
||
508: autoResetNoSystem:
|
||
===============
|
||
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
|
||
Operator designates any gateway system that can communicate to detect
|
||
current network environment.
|
||
System sends ICMP packet to the designated gateway system periodically.
|
||
If the system doesn't receive ping reply packet within any interval,
|
||
operator recognizes that the system can't communicate any more
|
||
because of some problems of the system.
|
||
510: autoResetNoPingReplyLoss:
|
||
===============
|
||
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
|
||
less than the configured free memory size or not.
|
||
Periodically, free memory size is checked to confirm system availability.
|
||
512: autoResetNoMemoryLeakDetect:
|
||
===============
|
||
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
|
||
602: arulePacketDropRelease:
|
||
===============
|
||
620: bME1CardNoDetect:
|
||
621: clearBME1CardNoDetect:
|
||
===============
|
||
622: bME1CardAFEerror:
|
||
623: clearBME1CardAFEerror:
|
||
===============
|
||
624: bME1CardIFEerror:
|
||
625: clearBME1CardIFEerror:
|
||
===============
|
||
626: bME1CardFWerror:
|
||
627: clearBME1CardFWerror:
|
||
===============
|
||
628: bME1CardPROVerror:
|
||
629: clearBME1CardPROVerror:
|
||
===============
|
||
630: bME1CrashDetect:
|
||
631: clearBME1CrashDetect:
|
||
===============
|
||
632: bME2CardNoDetect:
|
||
633: clearBME2CardNoDetect:
|
||
===============
|
||
634: bME2CardAFEerror:
|
||
635: clearBME2CardAFEerror:
|
||
===============
|
||
636: bME2CardIFEerror:
|
||
637: clearBME2CardIFEerror:
|
||
===============
|
||
638: bME2CardFWerror:
|
||
639: clearBME2CardFWerror:
|
||
===============
|
||
640: bME2CardPROVerror:
|
||
641: clearBME2CardPROVerror:
|
||
===============
|
||
642: bME2CrashDetect:
|
||
643: clearBME2CrashDetect:
|
||
===============
|
||
644: bME3CardNoDetect:
|
||
645: clearBME3CardNoDetect:
|
||
===============
|
||
646: bME3CardAFEerror:
|
||
647: clearBME3CardAFEerror:
|
||
===============
|
||
648: bME3CardIFEerror:
|
||
649: clearBME3CardIFEerror:
|
||
===============
|
||
650: bME3CardFWerror:
|
||
651: clearBME3CardFWerror:
|
||
===============
|
||
652: bME3CardPROVerror:
|
||
653: clearBME3CardPROVerror:
|
||
===============
|
||
654: bME3CrashDetect:
|
||
655: clearBME3CrashDetect:
|
||
===============
|
||
656: powerFromBattery:
|
||
657: clearPowerFromBattery:
|
||
===============
|
||
658: invalidBatteryStatus:
|
||
659: clearInvalidBatteryStatus:
|
||
===============
|
||
660: batteryChargeLow:
|
||
661: clearBatteryChargeLow:
|
||
===============
|
||
662: batteryNotPresent:
|
||
663: clearBatteryNotPresent:
|
||
===============
|
||
664: voltageLow:
|
||
665: clearVoltageLow:
|
||
===============
|
||
666: tempOverThreshold:
|
||
667: clearTempOverThreshold:
|
||
===============
|
||
668: tempUnderThreshold:
|
||
669: clearTempUnderThreshold:
|
||
===============
|
||
670: cpuOverThreshold:
|
||
671: clearCpuOverThreshold:
|
||
===============
|
||
672: trafficOverload:
|
||
673: clearTrafficOverload:
|
||
===============
|
||
674: gEPONModuleNotDetect:
|
||
675: clearGEPONModuleNotDetect:
|
||
===============
|
||
676: gEPONPortOperationDown:
|
||
677: clearGEPONPortOperationDown:
|
||
===============
|
||
678: gEPONNoIncomingTraffic:
|
||
679: clearGEPONNoIncomingTraffic:
|
||
===============
|
||
680: processCrashDetect:
|
||
681: clearProcessCrashDetect:
|
||
===============
|
||
682: memoryLeakDetect:
|
||
683: clearMemoryLeakDetect:
|
||
===============
|
||
684: memoryCorrupDetect:
|
||
685: clearMemoryCorrupDetect:
|
||
===============
|
||
686: memoryLowDetect:
|
||
687: clearMemoryLowDetect:
|
||
===============
|
||
688: dataLineerror:
|
||
689: clearDataLineerror:
|
||
===============
|
||
690: addressLineerror:
|
||
691: clearAddressLineerror:
|
||
===============
|
||
692: chipsetNotDetcet:
|
||
693: clearChipsetNotDetcet:
|
||
===============
|
||
694: pciBuserror:
|
||
695: clearPciBuserror:
|
||
===============
|
||
696: securityAdminConnect:
|
||
697: clearSecurityAdminConnect:
|
||
===============
|
||
698: oNUPowerDown:
|
||
699: clearONUPowerDown:
|
||
===============
|
||
700: oNUNotRegister:
|
||
701: clearONUNotRegister:
|
||
===============
|
||
702: oNTOpticPre:
|
||
703: clearONTOpticPre:
|
||
===============
|
||
800: switchoverInitiated:
|
||
===============
|
||
801: switchoverDone:
|
||
===============
|
||
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
|
||
===============
|
||
901: gponNoAuthCBU: To detect no auth CBU is detected.
|
||
902: gponDuplicateONU: To detect ONU is duplicated.
|
||
903: gponDyingGasp: To detect dying GASP is detected.
|
||
904: gponUpgradeComplete: To detect upgrade complete is detected.
|
||
905: gponDeregistered: To detect whether deregistered is detected or not.
|
||
906: gponRegistered:
|
||
907: gponRogueOnu: To detect rogue ONU is detected
|
||
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
|
||
909: clearGponOnuBetteryEvent:
|
||
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
|
||
911: gponTransceiverChanged: To detect transceiver is changed.
|
||
912: gponOltLosOn: To detect whether OLT LOS is on or off
|
||
913: gponOltLosOff:
|
||
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
|
||
915: gponOltLosiOff:
|
||
916: gponDyingGaspOn: To detect whether dying GASP is on or off
|
||
917: gponDyingGaspOff:
|
||
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
|
||
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
|
||
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
|
||
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
|
||
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
|
||
923: gponOnuTemperatureHighFallThreshold:
|
||
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
|
||
925: gponOnuTemperatureLowFallThreshold:
|
||
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
|
||
927: gponOnuCpuFallThreshold:
|
||
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
|
||
929: gponOnuMemoryFallThreshold:
|
||
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
|
||
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
|
||
932: gponOnuRxOpticLowThreshAlarmOff:
|
||
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
|
||
934: gponOnuRxOpticHighThreshAlarmOff:
|
||
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
|
||
936: gponOltLOFIOff:
|
||
937: gponOltDOWOn: To detect whether OLT DOW is on or off
|
||
938: gponOltDOWOff:
|
||
939: gponOltSFOn: To detect whether OLT SF is on or off
|
||
940: gponOltSFOff:
|
||
941: gponOltSDOn: To detect whether OLT SD is on or off
|
||
942: gponOltSDOff:
|
||
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
|
||
944: gponOltLCDGIOff:
|
||
945: gponOltRDOn: To detect whether OLT RD is on or off
|
||
946: gponOltRDOff:
|
||
947: gponOltSUFOn: To detect whether OLT SUF is on or off
|
||
948: gponOltSUFOff:
|
||
949: gponOltLOAOn: To detect whether OLT LOA is on or off
|
||
950: gponOltLOAOff:
|
||
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
|
||
952: gponOltLOAMIOff:
|
||
953: gponOltMEMOn: To detect whether OLT MEM is on or off
|
||
954: gponOltMEMOff:
|
||
955: gponOltPEEOn: To detect whether OLT PEE is on or off
|
||
956: gponOltPEEOff:
|
||
957: gponOltPSTOn: To detect whether OLT PST is on or off
|
||
958: gponOltPSTOff:
|
||
959: gponOltERROn: To detect whether OLT ERR is on or off
|
||
960: gponOltERROff:
|
||
961: gponOltREIOn: To detect whether OLT REI is on or off
|
||
962: gponOltREIOff:
|
||
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
|
||
964: gponAntiSpoofingDupPortOff:
|
||
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
|
||
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
|
||
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
|
||
968: gponOnuPortOpticModuleInstall:
|
||
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
|
||
970: gponOnuOMCCProblemCleared:
|
||
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
|
||
972: gponOltFixedTcontAlarmOff:
|
||
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
|
||
974: gponOltDynamicTcontAlarmOff:
|
||
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
|
||
976: gponOltPortCountAlarmOff:
|
||
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
|
||
978: gponOltCableDownAlarmOff:
|
||
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
|
||
980: gponOltDeactiveMonitorAlarmOff:
|
||
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
|
||
982: gponOltDfiOff:
|
||
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
|
||
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
|
||
986: gponOnuPortOperStatusUp::
|
||
===============
|
||
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
|
||
1102: emLogDefectCPUHighUnder:
|
||
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
|
||
1104: emLogTemperHighUnder:
|
||
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
|
||
1106: emLogTemperLowOver:
|
||
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
|
||
1108: emLogMemLowOver:
|
||
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
|
||
1110: emLogFanFailCleared:
|
||
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
|
||
1112: emLogPhyCRCFailCleared:
|
||
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
|
||
1114: emLogPhyDetectFailCleared:
|
||
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
|
||
1116: emLogSFUMateInitFailCleared:
|
||
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
|
||
1118: emLogDaemonHealthBadCleared:
|
||
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
|
||
1120: emLogGPIURavenLinkDownCleared:
|
||
===============
|
||
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
|
||
1152: slotNosUpgradeEnd:
|
||
===============
|
||
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
|
||
1332: gponOnuAniVoltageLowThreshAlarmOff:
|
||
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
|
||
1334: gponOnuAniVoltageHighThreshAlarmOff:
|
||
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
|
||
1336: gponOnuAniTemperatureLowThreshAlarmOff:
|
||
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
|
||
1338: gponOnuAniTemperatureHighThreshAlarmOff:
|
||
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
|
||
1340: gponOnuAniTxBiasLowThreshAlarmOff:
|
||
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
|
||
1342: gponOnuAniTxBiasHighThreshAlarmOff:
|
||
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
|
||
1344: gponOnuAniTxpowerLowThreshAlarmOff:
|
||
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
|
||
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
|
||
::= { sleAlarmSeverityControl 6 }
|
||
|
||
|
||
sleAlarmSeverityControlValue OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleAlarmSeverityControl 7 }
|
||
|
||
|
||
sleAlarmSeverityNotification OBJECT IDENTIFIER ::= { sleAlarmSeverity 3 }
|
||
|
||
|
||
sleAlarmSeveriityCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmSeverityNotification 1 }
|
||
|
||
|
||
sleAlarmSeveriityDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult, sleAlarmSeverityValue }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmSeverityNotification 2 }
|
||
|
||
|
||
sleAlarmSeverityChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmSeverityNotification 3 }
|
||
|
||
|
||
sleAlarmReport OBJECT IDENTIFIER ::= { sleFaultMgmt 3 }
|
||
|
||
|
||
sleAlarmReportTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAlarmReportEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The alarm list table is used to store all reported alarms. "
|
||
::= { sleAlarmReport 1 }
|
||
|
||
|
||
sleAlarmReportEntry OBJECT-TYPE
|
||
SYNTAX SleAlarmReportEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Entry of the alarm lis table. "
|
||
INDEX { sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource }
|
||
::= { sleAlarmReportTable 1 }
|
||
|
||
|
||
SleAlarmReportEntry ::=
|
||
SEQUENCE {
|
||
sleAlarmSpecificCode
|
||
SpecificNum,
|
||
sleAlarmReportingSourceType
|
||
INTEGER,
|
||
sleAlarmReportingSource
|
||
OCTET STRING,
|
||
sleAlarmSpecificSeverity
|
||
INTEGER,
|
||
sleAlarmSpecificProblem
|
||
Unsigned32,
|
||
sleAlarmSpecificProblemText
|
||
OCTET STRING,
|
||
sleAlarmTimeAndDate
|
||
Integer32,
|
||
sleAlarmSpecificSeqNum
|
||
Counter32,
|
||
sleAlarmReportPairType
|
||
INTEGER
|
||
}
|
||
|
||
sleAlarmSpecificCode OBJECT-TYPE
|
||
SYNTAX SpecificNum
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The OID of alarm.
|
||
The following alarms is devided by the specific character, ===============.
|
||
The division basis is that alarms is bounded or released.
|
||
|
||
001: portDown: To detect whether physical or logical interface's link status is up or down.
|
||
002: portUp:
|
||
===============
|
||
003: portRemoved: To detect whether physical interface is installed or not.
|
||
004: portInstalled:
|
||
===============
|
||
005: powerFail: To detect whether power module's operation status is good or not.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
006: powerOK:
|
||
===============
|
||
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
008: powerInstalled:
|
||
===============
|
||
009: fanFail: To detect whether FAN module's operation status is good or not.
|
||
010: fanOK:
|
||
===============
|
||
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
|
||
012: fanInstalled:
|
||
===============
|
||
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
|
||
014: moduleInstalled:
|
||
===============
|
||
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
|
||
===============
|
||
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
|
||
(This alarm isn<73><6E>t used current)
|
||
===============
|
||
017: broadcastOver: To detect the receipt of broadcast packet.
|
||
(This alarm isn<73><6E>t used current)
|
||
018: broadcastUnder:
|
||
===============
|
||
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
|
||
020: cpuUnderLoad:
|
||
===============
|
||
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
|
||
022: memoryUnderUsed:
|
||
===============
|
||
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
|
||
less than delta value of current interface's InOctects or not.
|
||
024: portUnderThreshold:
|
||
===============
|
||
025: temperatureHigh: To detect whether the configured system's temperature threshold is
|
||
less than current temperature or not.
|
||
026: temperatureLow:
|
||
===============
|
||
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
|
||
028: mfgdReleased:
|
||
===============
|
||
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
|
||
030: ipUnconflict:
|
||
===============
|
||
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
|
||
sufficient or not.
|
||
032: dhcpLeaseSufficient:
|
||
===============
|
||
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
|
||
034: dhcpRemovedIllegalEntry:
|
||
===============
|
||
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not. But alarm generation
|
||
would be issued by means of event type in RMON event.
|
||
036: rmonAlarmNoRising:
|
||
===============
|
||
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not.
|
||
But alarm generation would be issued by means of event type in RMON event.
|
||
038: rmonAlarmNoFalling:
|
||
===============
|
||
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
|
||
So STP reconfiguration doesn't use this edge ports.
|
||
===============
|
||
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So, Root guard prevents a new inserted node from being root bridge as well as
|
||
receiving a superior BPDU from root bridge.
|
||
but this node participates in STP topology reconfiguration.
|
||
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
|
||
===============
|
||
041: portSecurity: To detect whether interface is configured for security or not.
|
||
This can be used to prevent MAC from flooding as well as spoofing.
|
||
That is, As a result, this will obstruct an attack as like DoS attack.
|
||
===============
|
||
042: userLogin:
|
||
043: userLogout:
|
||
===============
|
||
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
|
||
052: igmpGroupLeaved:
|
||
===============
|
||
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
|
||
054: dhcpIpaddressFree:
|
||
===============
|
||
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
|
||
056: doorClosed:
|
||
===============
|
||
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
|
||
A system is using AC power usually.
|
||
If there is any power problems as like a power failure,
|
||
a system is using battery instead of AC power.
|
||
058: powerModeChangedBatteryToPower:
|
||
===============
|
||
059: batterylowcapacity: To detect whether current battery capacity is less
|
||
capacity threshold according to battery usage or not.
|
||
The capacity of AC power is 16 voltage and battery is 20.
|
||
Capacity threshold is configured by H/W specification.
|
||
So operator can't change it.
|
||
060: batterynormalcapacity:
|
||
===============
|
||
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
|
||
062: batterynormalTemperature:
|
||
===============
|
||
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
|
||
064: authenticationNofail:
|
||
===============
|
||
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
|
||
greater than temperature threshold or not.
|
||
066: psuAcNormalTemperature:
|
||
===============
|
||
067: batteryRemoved: To detect whether battery is equipped at network system or not.
|
||
Battery is used as redundancy power service. So operator can decide the installation of battery.
|
||
068: batteryEquipped:
|
||
===============
|
||
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
|
||
12.5 volt value is configured by H/W specification. So operator can't change it.
|
||
070: batteryNormalVoltage:
|
||
===============
|
||
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
|
||
072: adminAccessLogout:
|
||
===============
|
||
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
|
||
074: cfgdReleased:
|
||
===============
|
||
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
|
||
076: sfgdReleased:
|
||
===============
|
||
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
|
||
078: swWatchdogNormalState:
|
||
===============
|
||
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
|
||
080: swWatchdogClearError:
|
||
===============
|
||
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
|
||
082: ppsControlReleased:
|
||
===============
|
||
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
|
||
084: gotDMITempHighFallAlarm:
|
||
===============
|
||
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
|
||
086: gotDMITempLowFallAlarm:
|
||
===============
|
||
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
|
||
088: gotDMITempHighFallWarning:
|
||
===============
|
||
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
|
||
090: gotDMITempLowFallWarning:
|
||
===============
|
||
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
|
||
092: gotDMIVolHighFallAlarm:
|
||
===============
|
||
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
|
||
094: gotDMIVolLowFallAlarm:
|
||
===============
|
||
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
|
||
096: gotDMIVolHighFallWarning:
|
||
===============
|
||
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
|
||
098: gotDMIVolLowFallWarning:
|
||
===============
|
||
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
|
||
100: gotDMITxBiasHighFallAlarm:
|
||
===============
|
||
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
|
||
102: gotDMITxBiasLowFallAlarm:
|
||
===============
|
||
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
|
||
104: gotDMITxBiasHighFallWarning:
|
||
===============
|
||
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
|
||
106: gotDMITxBiasLowFallWarning:
|
||
===============
|
||
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
|
||
108: gotDMITxPowerHighFallAlarm:
|
||
===============
|
||
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
|
||
110: gotDMITxPowerLowFallAlarm:
|
||
===============
|
||
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
|
||
112: gotDMITxPowerHighFallWarning:
|
||
===============
|
||
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
|
||
114: gotDMITxPowerLowFallWarning:
|
||
===============
|
||
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
|
||
116: gotDMIRxPowerHighFallAlarm:
|
||
===============
|
||
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
|
||
118: gotDMIRxPowerLowFallAlarm:
|
||
===============
|
||
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
|
||
120: gotDMIRxPowerHighFallWarning:
|
||
===============
|
||
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
|
||
122: gotDMIRxPowerLowFallWarning:
|
||
===============
|
||
123: nosRemoteUpgradeRequest:
|
||
124: nosRemoteUpgradeSuccess:
|
||
125: nosRemoteUpgradeFailAbort:
|
||
126: nosRemoteUpgradeFailHeaderError:
|
||
127: nosRemoteUpgradeFailDownloadError:
|
||
128: nosRemoteUpgradeFailFlashError:
|
||
129: nosRemoteUpgradeStart:
|
||
===============
|
||
130: systemDyingGasp:
|
||
===============
|
||
133: cliHistory: To detect whether CLI history is detected or not.
|
||
134: cliHistoryNo:
|
||
===============
|
||
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
|
||
136: ntpConnectionFailNo:
|
||
===============
|
||
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
|
||
===============
|
||
159: clockModuleRemoved: To detect whether clock module is removed or installed.
|
||
160: clockModuleInstalled:
|
||
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
|
||
162: clockModuleInitOk:
|
||
===============
|
||
163: cliHistoryLog: To detect whether CLI history log is over or not.
|
||
164: cliHistoryLogNo:
|
||
===============
|
||
165: slotActionEvent: To detect whether slot action is changed.
|
||
166: slotStateChange: To detect whether slot state is changed.
|
||
===============
|
||
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
|
||
168: interfaceAdminUp:
|
||
===============
|
||
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
|
||
170: slotPowerMonNormal:
|
||
===============
|
||
171: slotErrorLEDChanged: To detect whether error LED is changed.
|
||
===============
|
||
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
|
||
186: cpuPpsUnderThreshold:
|
||
===============
|
||
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
|
||
200: slotHealthStatusTimeoutCleared:
|
||
===============
|
||
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
|
||
202: advaTemperatureNo:
|
||
===============
|
||
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
|
||
204: advaPSUFailureNo:
|
||
===============
|
||
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
|
||
206: advaFanFailureNo:
|
||
===============
|
||
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
|
||
208: advaInterfaceReceiveFailureNo:
|
||
===============
|
||
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
|
||
less than optical threshold or not.
|
||
210: advaInterfaceOpticalThresholdNo:
|
||
===============
|
||
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
|
||
212: advaInterfaceTransmitFaultNo:
|
||
===============
|
||
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
|
||
214: advaInterfaceMisconfigurationNo:
|
||
===============
|
||
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
|
||
216: advaInterfaceSFPMismatchNo:
|
||
===============
|
||
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
|
||
218: advaVoltageLowNo:
|
||
===============
|
||
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
|
||
220: advaVoltageHighNo:
|
||
===============
|
||
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a node does not receive
|
||
any test packet at any of its ports for a period of 3 times.
|
||
302: erpDomainLotpNo:
|
||
===============
|
||
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a RM node of one domain does not
|
||
receive any test packet at one port for a period of 3 times.
|
||
304: erpDomainULotpNo:
|
||
===============
|
||
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
|
||
The defect is raised when a RM node receives its own test packets
|
||
with an Ack destination address field with a non-zero value.
|
||
306: erpDomainMultipleRMNo:
|
||
===============
|
||
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
|
||
The detection of multiple failures indicates that the ring is segmented and
|
||
that the RM Node is unreacheable.
|
||
This is only possible at normal ring nodes isolated from the RM node.
|
||
308: erpDomainRMNodeReacheablityNo:
|
||
===============
|
||
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
|
||
===============
|
||
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
|
||
That is, ONU that its operation is service on should be sent registration information to OLT.
|
||
402: eponOnuRegister:
|
||
===============
|
||
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
|
||
404: eponOnuNoRegistrationError:
|
||
===============
|
||
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
|
||
A message between ONU and OLT is encrypted using random encryption key.
|
||
There is that the encryption key is invalid as transmission failure from time to time.
|
||
406: eponNoBadEncryptionKey:
|
||
===============
|
||
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
|
||
On registering, ONU informs unique ID to OLT.
|
||
And then, all communication between ONU and OLT must use the unique ID.
|
||
The unique ID is called Llid.
|
||
408: eponNoLlidMismatch:
|
||
===============
|
||
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
|
||
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
|
||
410: eponNoTooManyRegister:
|
||
===============
|
||
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
|
||
A ONU could be changed to down state as a number of reasons.
|
||
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
|
||
then ONU's link would be changed to down.
|
||
412: eponNoDyingGASP:
|
||
===============
|
||
413: eponOnuErrFramePeriod:
|
||
414: eponOnuNoErrFramePeriod:
|
||
===============
|
||
415: eponOnuErrFrame:
|
||
416: eponOnuNoErrFrame:
|
||
===============
|
||
417: eponOnuErrFrameSecondSummary:
|
||
418: eponOnuNoErrFrameSecondSummary:
|
||
===============
|
||
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
|
||
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
|
||
420: eponOnuNoLastOnuDeregister:
|
||
===============
|
||
421: eponOltCableDown:
|
||
422: eponOltRecoverCableDown:
|
||
===============
|
||
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
|
||
502: autoCLINoStart:
|
||
===============
|
||
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
|
||
504: autoCLINoComplete:
|
||
===============
|
||
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
|
||
The reason that the result file is removed is that the configured file size for the result is
|
||
less than the stored result file size.
|
||
If so, the oldest file would be removed before everything.
|
||
506: autoCLINoRemoveOutputFile:
|
||
===============
|
||
507: autoResetSystem: To detect whether the system is restarted or not.
|
||
The conditions that system is restarted is that ping loss threshold is
|
||
less than current ping loss count during the configured interval and
|
||
that current free memory size is less than configured free memory size.
|
||
508: autoResetNoSystem:
|
||
===============
|
||
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
|
||
Operator designates any gateway system that can communicate to detect
|
||
current network environment.
|
||
System sends ICMP packet to the designated gateway system periodically.
|
||
If the system doesn't receive ping reply packet within any interval,
|
||
operator recognizes that the system can't communicate any more
|
||
because of some problems of the system.
|
||
510: autoResetNoPingReplyLoss:
|
||
===============
|
||
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
|
||
less than the configured free memory size or not.
|
||
Periodically, free memory size is checked to confirm system availability.
|
||
512: autoResetNoMemoryLeakDetect:
|
||
===============
|
||
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
|
||
602: arulePacketDropRelease:
|
||
===============
|
||
620: bME1CardNoDetect:
|
||
621: clearBME1CardNoDetect:
|
||
===============
|
||
622: bME1CardAFEerror:
|
||
623: clearBME1CardAFEerror:
|
||
===============
|
||
624: bME1CardIFEerror:
|
||
625: clearBME1CardIFEerror:
|
||
===============
|
||
626: bME1CardFWerror:
|
||
627: clearBME1CardFWerror:
|
||
===============
|
||
628: bME1CardPROVerror:
|
||
629: clearBME1CardPROVerror:
|
||
===============
|
||
630: bME1CrashDetect:
|
||
631: clearBME1CrashDetect:
|
||
===============
|
||
632: bME2CardNoDetect:
|
||
633: clearBME2CardNoDetect:
|
||
===============
|
||
634: bME2CardAFEerror:
|
||
635: clearBME2CardAFEerror:
|
||
===============
|
||
636: bME2CardIFEerror:
|
||
637: clearBME2CardIFEerror:
|
||
===============
|
||
638: bME2CardFWerror:
|
||
639: clearBME2CardFWerror:
|
||
===============
|
||
640: bME2CardPROVerror:
|
||
641: clearBME2CardPROVerror:
|
||
===============
|
||
642: bME2CrashDetect:
|
||
643: clearBME2CrashDetect:
|
||
===============
|
||
644: bME3CardNoDetect:
|
||
645: clearBME3CardNoDetect:
|
||
===============
|
||
646: bME3CardAFEerror:
|
||
647: clearBME3CardAFEerror:
|
||
===============
|
||
648: bME3CardIFEerror:
|
||
649: clearBME3CardIFEerror:
|
||
===============
|
||
650: bME3CardFWerror:
|
||
651: clearBME3CardFWerror:
|
||
===============
|
||
652: bME3CardPROVerror:
|
||
653: clearBME3CardPROVerror:
|
||
===============
|
||
654: bME3CrashDetect:
|
||
655: clearBME3CrashDetect:
|
||
===============
|
||
656: powerFromBattery:
|
||
657: clearPowerFromBattery:
|
||
===============
|
||
658: invalidBatteryStatus:
|
||
659: clearInvalidBatteryStatus:
|
||
===============
|
||
660: batteryChargeLow:
|
||
661: clearBatteryChargeLow:
|
||
===============
|
||
662: batteryNotPresent:
|
||
663: clearBatteryNotPresent:
|
||
===============
|
||
664: voltageLow:
|
||
665: clearVoltageLow:
|
||
===============
|
||
666: tempOverThreshold:
|
||
667: clearTempOverThreshold:
|
||
===============
|
||
668: tempUnderThreshold:
|
||
669: clearTempUnderThreshold:
|
||
===============
|
||
670: cpuOverThreshold:
|
||
671: clearCpuOverThreshold:
|
||
===============
|
||
672: trafficOverload:
|
||
673: clearTrafficOverload:
|
||
===============
|
||
674: gEPONModuleNotDetect:
|
||
675: clearGEPONModuleNotDetect:
|
||
===============
|
||
676: gEPONPortOperationDown:
|
||
677: clearGEPONPortOperationDown:
|
||
===============
|
||
678: gEPONNoIncomingTraffic:
|
||
679: clearGEPONNoIncomingTraffic:
|
||
===============
|
||
680: processCrashDetect:
|
||
681: clearProcessCrashDetect:
|
||
===============
|
||
682: memoryLeakDetect:
|
||
683: clearMemoryLeakDetect:
|
||
===============
|
||
684: memoryCorrupDetect:
|
||
685: clearMemoryCorrupDetect:
|
||
===============
|
||
686: memoryLowDetect:
|
||
687: clearMemoryLowDetect:
|
||
===============
|
||
688: dataLineerror:
|
||
689: clearDataLineerror:
|
||
===============
|
||
690: addressLineerror:
|
||
691: clearAddressLineerror:
|
||
===============
|
||
692: chipsetNotDetcet:
|
||
693: clearChipsetNotDetcet:
|
||
===============
|
||
694: pciBuserror:
|
||
695: clearPciBuserror:
|
||
===============
|
||
696: securityAdminConnect:
|
||
697: clearSecurityAdminConnect:
|
||
===============
|
||
698: oNUPowerDown:
|
||
699: clearONUPowerDown:
|
||
===============
|
||
700: oNUNotRegister:
|
||
701: clearONUNotRegister:
|
||
===============
|
||
702: oNTOpticPre:
|
||
703: clearONTOpticPre:
|
||
===============
|
||
800: switchoverInitiated:
|
||
===============
|
||
801: switchoverDone:
|
||
===============
|
||
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
|
||
===============
|
||
901: gponNoAuthCBU: To detect no auth CBU is detected.
|
||
902: gponDuplicateONU: To detect ONU is duplicated.
|
||
903: gponDyingGasp: To detect dying GASP is detected.
|
||
904: gponUpgradeComplete: To detect upgrade complete is detected.
|
||
905: gponDeregistered: To detect whether deregistered is detected or not.
|
||
906: gponRegistered:
|
||
907: gponRogueOnu: To detect rogue ONU is detected
|
||
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
|
||
909: clearGponOnuBetteryEvent:
|
||
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
|
||
911: gponTransceiverChanged: To detect transceiver is changed.
|
||
912: gponOltLosOn: To detect whether OLT LOS is on or off
|
||
913: gponOltLosOff:
|
||
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
|
||
915: gponOltLosiOff:
|
||
916: gponDyingGaspOn: To detect whether dying GASP is on or off
|
||
917: gponDyingGaspOff:
|
||
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
|
||
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
|
||
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
|
||
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
|
||
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
|
||
923: gponOnuTemperatureHighFallThreshold:
|
||
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
|
||
925: gponOnuTemperatureLowFallThreshold:
|
||
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
|
||
927: gponOnuCpuFallThreshold:
|
||
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
|
||
929: gponOnuMemoryFallThreshold:
|
||
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
|
||
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
|
||
932: gponOnuRxOpticLowThreshAlarmOff:
|
||
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
|
||
934: gponOnuRxOpticHighThreshAlarmOff:
|
||
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
|
||
936: gponOltLOFIOff:
|
||
937: gponOltDOWOn: To detect whether OLT DOW is on or off
|
||
938: gponOltDOWOff:
|
||
939: gponOltSFOn: To detect whether OLT SF is on or off
|
||
940: gponOltSFOff:
|
||
941: gponOltSDOn: To detect whether OLT SD is on or off
|
||
942: gponOltSDOff:
|
||
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
|
||
944: gponOltLCDGIOff:
|
||
945: gponOltRDOn: To detect whether OLT RD is on or off
|
||
946: gponOltRDOff:
|
||
947: gponOltSUFOn: To detect whether OLT SUF is on or off
|
||
948: gponOltSUFOff:
|
||
949: gponOltLOAOn: To detect whether OLT LOA is on or off
|
||
950: gponOltLOAOff:
|
||
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
|
||
952: gponOltLOAMIOff:
|
||
953: gponOltMEMOn: To detect whether OLT MEM is on or off
|
||
954: gponOltMEMOff:
|
||
955: gponOltPEEOn: To detect whether OLT PEE is on or off
|
||
956: gponOltPEEOff:
|
||
957: gponOltPSTOn: To detect whether OLT PST is on or off
|
||
958: gponOltPSTOff:
|
||
959: gponOltERROn: To detect whether OLT ERR is on or off
|
||
960: gponOltERROff:
|
||
961: gponOltREIOn: To detect whether OLT REI is on or off
|
||
962: gponOltREIOff:
|
||
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
|
||
964: gponAntiSpoofingDupPortOff:
|
||
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
|
||
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
|
||
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
|
||
968: gponOnuPortOpticModuleInstall:
|
||
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
|
||
970: gponOnuOMCCProblemCleared:
|
||
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
|
||
972: gponOltFixedTcontAlarmOff:
|
||
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
|
||
974: gponOltDynamicTcontAlarmOff:
|
||
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
|
||
976: gponOltPortCountAlarmOff:
|
||
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
|
||
978: gponOltCableDownAlarmOff:
|
||
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
|
||
980: gponOltDeactiveMonitorAlarmOff:
|
||
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
|
||
982: gponOltDfiOff:
|
||
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
|
||
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
|
||
986: gponOnuPortOperStatusUp::
|
||
===============
|
||
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
|
||
1102: emLogDefectCPUHighUnder:
|
||
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
|
||
1104: emLogTemperHighUnder:
|
||
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
|
||
1106: emLogTemperLowOver:
|
||
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
|
||
1108: emLogMemLowOver:
|
||
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
|
||
1110: emLogFanFailCleared:
|
||
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
|
||
1112: emLogPhyCRCFailCleared:
|
||
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
|
||
1114: emLogPhyDetectFailCleared:
|
||
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
|
||
1116: emLogSFUMateInitFailCleared:
|
||
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
|
||
1118: emLogDaemonHealthBadCleared:
|
||
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
|
||
1120: emLogGPIURavenLinkDownCleared:
|
||
===============
|
||
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
|
||
1152: slotNosUpgradeEnd:
|
||
===============
|
||
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
|
||
1332: gponOnuAniVoltageLowThreshAlarmOff:
|
||
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
|
||
1334: gponOnuAniVoltageHighThreshAlarmOff:
|
||
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
|
||
1336: gponOnuAniTemperatureLowThreshAlarmOff:
|
||
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
|
||
1338: gponOnuAniTemperatureHighThreshAlarmOff:
|
||
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
|
||
1340: gponOnuAniTxBiasLowThreshAlarmOff:
|
||
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
|
||
1342: gponOnuAniTxBiasHighThreshAlarmOff:
|
||
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
|
||
1344: gponOnuAniTxpowerLowThreshAlarmOff:
|
||
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
|
||
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
|
||
::= { sleAlarmReportEntry 1 }
|
||
|
||
|
||
sleAlarmReportingSourceType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
entPhysicalEntity(1),
|
||
ifIndex(2),
|
||
vccTp(3),
|
||
macAddress(4),
|
||
ipv4(5),
|
||
ipv6(6),
|
||
threshold(7),
|
||
advaSource(8),
|
||
number(9),
|
||
general(10),
|
||
eponSource(11),
|
||
gponSource(12),
|
||
gponSourceTlv(13)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of Reporting source
|
||
|
||
In case of source type 13 gponSourceTlv,
|
||
It's shown as below.
|
||
sleAlarmReportingSourceType.A.B.C.D.E.F
|
||
A: sleAlarmSpecificCode
|
||
B: sleAlarmReportingSourceType 13
|
||
C: sleAlarmReportingSource's length
|
||
D: type 1-slot 2-port 3-vlan 4-MAC 5-ONU 6-UNI_type 7-UNI_index 255-etc
|
||
E: legth
|
||
F: value
|
||
"
|
||
::= { sleAlarmReportEntry 2 }
|
||
|
||
|
||
sleAlarmReportingSource OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..64))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The alarm severity of alarm.
|
||
|
||
In case of source type 13 gponSourceTlv,
|
||
It's shown as below.
|
||
sleAlarmReportingSourceType.A.B.C.D.E.F
|
||
A: sleAlarmSpecificCode
|
||
B: sleAlarmReportingSourceType 13
|
||
C: sleAlarmReportingSource's length
|
||
D: type 1-slot 2-port 3-vlan 4-MAC 5-ONU 6-UNI_type 7-UNI_index 255-etc
|
||
E: legth
|
||
F: value"
|
||
::= { sleAlarmReportEntry 3 }
|
||
|
||
|
||
sleAlarmSpecificSeverity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5),
|
||
cleared(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The alarm severity. The value cleared indicates the clearing of alarm."
|
||
::= { sleAlarmReportEntry 4 }
|
||
|
||
|
||
sleAlarmSpecificProblem OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Describes the spefic problems e.g. when a shePhysCardFailure is sent here the termperature alarm is specified"
|
||
::= { sleAlarmReportEntry 5 }
|
||
|
||
|
||
sleAlarmSpecificProblemText OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Textual description of specific problem reported by alarming.
|
||
To be discussed: Option is to define an alarm for every problem
|
||
"
|
||
::= { sleAlarmReportEntry 6 }
|
||
|
||
|
||
sleAlarmTimeAndDate OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The date and time when the alarm appeared or cleared"
|
||
::= { sleAlarmReportEntry 7 }
|
||
|
||
|
||
sleAlarmSpecificSeqNum OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sequence number for the alarm synchronization.
|
||
This value has a number to be used for the next alarm trap."
|
||
::= { sleAlarmReportEntry 8 }
|
||
|
||
|
||
sleAlarmReportPairType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
pair(0),
|
||
mono(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type is whether alarm trap is pair or mono."
|
||
::= { sleAlarmReportEntry 9 }
|
||
|
||
|
||
sleAlarmReportNotification OBJECT IDENTIFIER ::= { sleAlarmReport 2 }
|
||
|
||
|
||
sleAlarmReportNotified NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource, sleAlarmTimeAndDate, sleAlarmSpecificSeverity,
|
||
sleAlarmSpecificProblem, sleAlarmSpecificProblemText, sleAlarmSpecificSeqNum }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportNotification 1 }
|
||
|
||
|
||
sleAlarmReportControl OBJECT IDENTIFIER ::= { sleAlarmReport 3 }
|
||
|
||
|
||
sleAlarmReportControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clearAlarmReport(1),
|
||
delAlarmReport(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportControl 1 }
|
||
|
||
|
||
sleAlarmReportControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportControl 2 }
|
||
|
||
|
||
sleAlarmReportControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportControl 3 }
|
||
|
||
|
||
sleAlarmReportControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportControl 4 }
|
||
|
||
|
||
sleAlarmReportControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportControl 5 }
|
||
|
||
|
||
sleAlarmReportControlSpecificCode OBJECT-TYPE
|
||
SYNTAX SpecificNum
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm specific code"
|
||
::= { sleAlarmReportControl 6 }
|
||
|
||
|
||
sleAlarmReportControlSourceType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
entPhysicalEntity(1),
|
||
ifIndex(2),
|
||
vccTp(3),
|
||
macAddress(4),
|
||
ipv4(5),
|
||
ipv6(6),
|
||
threshold(7),
|
||
advaSource(8),
|
||
number(9),
|
||
general(10),
|
||
eponSource(11),
|
||
gponSource(12)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type of Reporting source"
|
||
::= { sleAlarmReportControl 7 }
|
||
|
||
|
||
sleAlarmReportControlSource OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..255))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The index of the failed component which reports the alarm.
|
||
It is the entPhysicalIndex in case of a card is reporting, or the ifIndex in case of an interface reporting"
|
||
::= { sleAlarmReportControl 8 }
|
||
|
||
|
||
sleAlarmReportNotifications OBJECT IDENTIFIER ::= { sleAlarmReport 4 }
|
||
|
||
|
||
sleAlarmReportCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmReportControlRequest, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportNotifications 1 }
|
||
|
||
|
||
sleAlarmReportDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmReportControlRequest, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult, sleAlarmReportControlSpecificCode, sleAlarmReportControlSourceType,
|
||
sleAlarmReportControlSource }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmReportNotifications 2 }
|
||
|
||
|
||
sleAlarmHistory OBJECT IDENTIFIER ::= { sleFaultMgmt 4 }
|
||
|
||
|
||
sleAlarmHistoryTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAlarmHistoryEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The alarm severity table.
|
||
The alarm severity table associates
|
||
profile index and AlarmID pairs with severities to be
|
||
used for alarm traps.
|
||
(Note that this table does not apply to cleared alarms). "
|
||
::= { sleAlarmHistory 1 }
|
||
|
||
|
||
sleAlarmHistoryEntry OBJECT-TYPE
|
||
SYNTAX SleAlarmHistoryEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" Entry of the alarm severity table. "
|
||
INDEX { sleAlarmHistoryIndex }
|
||
::= { sleAlarmHistoryTable 1 }
|
||
|
||
|
||
SleAlarmHistoryEntry ::=
|
||
SEQUENCE {
|
||
sleAlarmHistoryIndex
|
||
INTEGER,
|
||
sleAlarmHistorySpecific
|
||
SpecificNum,
|
||
sleAlarmHistorySeverity
|
||
INTEGER,
|
||
sleAlarmHistoryText
|
||
OCTET STRING,
|
||
sleAlarmHistoryTime
|
||
Integer32,
|
||
sleAlarmHistorySeqNum
|
||
Counter32,
|
||
sleAlarmHistoryPairType
|
||
INTEGER
|
||
}
|
||
|
||
sleAlarmHistoryIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The OID of alarm. "
|
||
::= { sleAlarmHistoryEntry 1 }
|
||
|
||
|
||
sleAlarmHistorySpecific OBJECT-TYPE
|
||
SYNTAX SpecificNum
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The OID of alarm.
|
||
The following alarms is devided by the specific character, ===============.
|
||
The division basis is that alarms is bounded or released.
|
||
|
||
001: portDown: To detect whether physical or logical interface's link status is up or down.
|
||
002: portUp:
|
||
===============
|
||
003: portRemoved: To detect whether physical interface is installed or not.
|
||
004: portInstalled:
|
||
===============
|
||
005: powerFail: To detect whether power module's operation status is good or not.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
006: powerOK:
|
||
===============
|
||
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
|
||
(Without doubt, more than 1 power module should be equipped.)
|
||
008: powerInstalled:
|
||
===============
|
||
009: fanFail: To detect whether FAN module's operation status is good or not.
|
||
010: fanOK:
|
||
===============
|
||
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
|
||
012: fanInstalled:
|
||
===============
|
||
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
|
||
014: moduleInstalled:
|
||
===============
|
||
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
|
||
===============
|
||
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
|
||
(This alarm isn<73><6E>t used current)
|
||
===============
|
||
017: broadcastOver: To detect the receipt of broadcast packet.
|
||
(This alarm isn<73><6E>t used current)
|
||
018: broadcastUnder:
|
||
===============
|
||
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
|
||
020: cpuUnderLoad:
|
||
===============
|
||
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
|
||
022: memoryUnderUsed:
|
||
===============
|
||
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
|
||
less than delta value of current interface's InOctects or not.
|
||
024: portUnderThreshold:
|
||
===============
|
||
025: temperatureHigh: To detect whether the configured system's temperature threshold is
|
||
less than current temperature or not.
|
||
026: temperatureLow:
|
||
===============
|
||
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
|
||
028: mfgdReleased:
|
||
===============
|
||
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
|
||
030: ipUnconflict:
|
||
===============
|
||
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
|
||
sufficient or not.
|
||
032: dhcpLeaseSufficient:
|
||
===============
|
||
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
|
||
034: dhcpRemovedIllegalEntry:
|
||
===============
|
||
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not. But alarm generation
|
||
would be issued by means of event type in RMON event.
|
||
036: rmonAlarmNoRising:
|
||
===============
|
||
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
|
||
less than current calculated value by alarm sample type or not.
|
||
But alarm generation would be issued by means of event type in RMON event.
|
||
038: rmonAlarmNoFalling:
|
||
===============
|
||
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
|
||
So STP reconfiguration doesn't use this edge ports.
|
||
===============
|
||
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
|
||
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
|
||
it will be disarrangement during a short time because of recognition a new inserted node
|
||
as root bridge.
|
||
So, Root guard prevents a new inserted node from being root bridge as well as
|
||
receiving a superior BPDU from root bridge.
|
||
but this node participates in STP topology reconfiguration.
|
||
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
|
||
===============
|
||
041: portSecurity: To detect whether interface is configured for security or not.
|
||
This can be used to prevent MAC from flooding as well as spoofing.
|
||
That is, As a result, this will obstruct an attack as like DoS attack.
|
||
===============
|
||
042: userLogin:
|
||
043: userLogout:
|
||
===============
|
||
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
|
||
052: igmpGroupLeaved:
|
||
===============
|
||
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
|
||
054: dhcpIpaddressFree:
|
||
===============
|
||
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
|
||
056: doorClosed:
|
||
===============
|
||
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
|
||
A system is using AC power usually.
|
||
If there is any power problems as like a power failure,
|
||
a system is using battery instead of AC power.
|
||
058: powerModeChangedBatteryToPower:
|
||
===============
|
||
059: batterylowcapacity: To detect whether current battery capacity is less
|
||
capacity threshold according to battery usage or not.
|
||
The capacity of AC power is 16 voltage and battery is 20.
|
||
Capacity threshold is configured by H/W specification.
|
||
So operator can't change it.
|
||
060: batterynormalcapacity:
|
||
===============
|
||
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
|
||
062: batterynormalTemperature:
|
||
===============
|
||
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
|
||
064: authenticationNofail:
|
||
===============
|
||
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
|
||
greater than temperature threshold or not.
|
||
066: psuAcNormalTemperature:
|
||
===============
|
||
067: batteryRemoved: To detect whether battery is equipped at network system or not.
|
||
Battery is used as redundancy power service. So operator can decide the installation of battery.
|
||
068: batteryEquipped:
|
||
===============
|
||
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
|
||
12.5 volt value is configured by H/W specification. So operator can't change it.
|
||
070: batteryNormalVoltage:
|
||
===============
|
||
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
|
||
072: adminAccessLogout:
|
||
===============
|
||
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
|
||
074: cfgdReleased:
|
||
===============
|
||
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
|
||
076: sfgdReleased:
|
||
===============
|
||
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
|
||
078: swWatchdogNormalState:
|
||
===============
|
||
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
|
||
080: swWatchdogClearError:
|
||
===============
|
||
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
|
||
082: ppsControlReleased:
|
||
===============
|
||
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
|
||
084: gotDMITempHighFallAlarm:
|
||
===============
|
||
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
|
||
086: gotDMITempLowFallAlarm:
|
||
===============
|
||
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
|
||
088: gotDMITempHighFallWarning:
|
||
===============
|
||
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
|
||
090: gotDMITempLowFallWarning:
|
||
===============
|
||
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
|
||
092: gotDMIVolHighFallAlarm:
|
||
===============
|
||
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
|
||
094: gotDMIVolLowFallAlarm:
|
||
===============
|
||
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
|
||
096: gotDMIVolHighFallWarning:
|
||
===============
|
||
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
|
||
098: gotDMIVolLowFallWarning:
|
||
===============
|
||
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
|
||
100: gotDMITxBiasHighFallAlarm:
|
||
===============
|
||
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
|
||
102: gotDMITxBiasLowFallAlarm:
|
||
===============
|
||
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
|
||
104: gotDMITxBiasHighFallWarning:
|
||
===============
|
||
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
|
||
106: gotDMITxBiasLowFallWarning:
|
||
===============
|
||
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
|
||
108: gotDMITxPowerHighFallAlarm:
|
||
===============
|
||
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
|
||
110: gotDMITxPowerLowFallAlarm:
|
||
===============
|
||
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
|
||
112: gotDMITxPowerHighFallWarning:
|
||
===============
|
||
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
|
||
114: gotDMITxPowerLowFallWarning:
|
||
===============
|
||
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
|
||
116: gotDMIRxPowerHighFallAlarm:
|
||
===============
|
||
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
|
||
118: gotDMIRxPowerLowFallAlarm:
|
||
===============
|
||
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
|
||
120: gotDMIRxPowerHighFallWarning:
|
||
===============
|
||
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
|
||
122: gotDMIRxPowerLowFallWarning:
|
||
===============
|
||
123: nosRemoteUpgradeRequest:
|
||
124: nosRemoteUpgradeSuccess:
|
||
125: nosRemoteUpgradeFailAbort:
|
||
126: nosRemoteUpgradeFailHeaderError:
|
||
127: nosRemoteUpgradeFailDownloadError:
|
||
128: nosRemoteUpgradeFailFlashError:
|
||
129: nosRemoteUpgradeStart:
|
||
===============
|
||
130: systemDyingGasp:
|
||
===============
|
||
133: cliHistory: To detect whether CLI history is detected or not.
|
||
134: cliHistoryNo:
|
||
===============
|
||
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
|
||
136: ntpConnectionFailNo:
|
||
===============
|
||
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
|
||
===============
|
||
159: clockModuleRemoved: To detect whether clock module is removed or installed.
|
||
160: clockModuleInstalled:
|
||
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
|
||
162: clockModuleInitOk:
|
||
===============
|
||
163: cliHistoryLog: To detect whether CLI history log is over or not.
|
||
164: cliHistoryLogNo:
|
||
===============
|
||
165: slotActionEvent: To detect whether slot action is changed.
|
||
166: slotStateChange: To detect whether slot state is changed.
|
||
===============
|
||
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
|
||
168: interfaceAdminUp:
|
||
===============
|
||
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
|
||
170: slotPowerMonNormal:
|
||
===============
|
||
171: slotErrorLEDChanged: To detect whether error LED is changed.
|
||
===============
|
||
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
|
||
186: cpuPpsUnderThreshold:
|
||
===============
|
||
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
|
||
200: slotHealthStatusTimeoutCleared:
|
||
===============
|
||
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
|
||
202: advaTemperatureNo:
|
||
===============
|
||
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
|
||
204: advaPSUFailureNo:
|
||
===============
|
||
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
|
||
206: advaFanFailureNo:
|
||
===============
|
||
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
|
||
208: advaInterfaceReceiveFailureNo:
|
||
===============
|
||
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
|
||
less than optical threshold or not.
|
||
210: advaInterfaceOpticalThresholdNo:
|
||
===============
|
||
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
|
||
212: advaInterfaceTransmitFaultNo:
|
||
===============
|
||
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
|
||
214: advaInterfaceMisconfigurationNo:
|
||
===============
|
||
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
|
||
216: advaInterfaceSFPMismatchNo:
|
||
===============
|
||
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
|
||
218: advaVoltageLowNo:
|
||
===============
|
||
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
|
||
220: advaVoltageHighNo:
|
||
===============
|
||
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a node does not receive
|
||
any test packet at any of its ports for a period of 3 times.
|
||
302: erpDomainLotpNo:
|
||
===============
|
||
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
|
||
The Loss of Test Packet defect is defined when a RM node of one domain does not
|
||
receive any test packet at one port for a period of 3 times.
|
||
304: erpDomainULotpNo:
|
||
===============
|
||
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
|
||
The defect is raised when a RM node receives its own test packets
|
||
with an Ack destination address field with a non-zero value.
|
||
306: erpDomainMultipleRMNo:
|
||
===============
|
||
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
|
||
The detection of multiple failures indicates that the ring is segmented and
|
||
that the RM Node is unreacheable.
|
||
This is only possible at normal ring nodes isolated from the RM node.
|
||
308: erpDomainRMNodeReacheablityNo:
|
||
===============
|
||
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
|
||
===============
|
||
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
|
||
That is, ONU that its operation is service on should be sent registration information to OLT.
|
||
402: eponOnuRegister:
|
||
===============
|
||
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
|
||
404: eponOnuNoRegistrationError:
|
||
===============
|
||
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
|
||
A message between ONU and OLT is encrypted using random encryption key.
|
||
There is that the encryption key is invalid as transmission failure from time to time.
|
||
406: eponNoBadEncryptionKey:
|
||
===============
|
||
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
|
||
On registering, ONU informs unique ID to OLT.
|
||
And then, all communication between ONU and OLT must use the unique ID.
|
||
The unique ID is called Llid.
|
||
408: eponNoLlidMismatch:
|
||
===============
|
||
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
|
||
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
|
||
410: eponNoTooManyRegister:
|
||
===============
|
||
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
|
||
A ONU could be changed to down state as a number of reasons.
|
||
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
|
||
then ONU's link would be changed to down.
|
||
412: eponNoDyingGASP:
|
||
===============
|
||
413: eponOnuErrFramePeriod:
|
||
414: eponOnuNoErrFramePeriod:
|
||
===============
|
||
415: eponOnuErrFrame:
|
||
416: eponOnuNoErrFrame:
|
||
===============
|
||
417: eponOnuErrFrameSecondSummary:
|
||
418: eponOnuNoErrFrameSecondSummary:
|
||
===============
|
||
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
|
||
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
|
||
420: eponOnuNoLastOnuDeregister:
|
||
===============
|
||
421: eponOltCableDown:
|
||
422: eponOltRecoverCableDown:
|
||
===============
|
||
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
|
||
502: autoCLINoStart:
|
||
===============
|
||
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
|
||
504: autoCLINoComplete:
|
||
===============
|
||
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
|
||
The reason that the result file is removed is that the configured file size for the result is
|
||
less than the stored result file size.
|
||
If so, the oldest file would be removed before everything.
|
||
506: autoCLINoRemoveOutputFile:
|
||
===============
|
||
507: autoResetSystem: To detect whether the system is restarted or not.
|
||
The conditions that system is restarted is that ping loss threshold is
|
||
less than current ping loss count during the configured interval and
|
||
that current free memory size is less than configured free memory size.
|
||
508: autoResetNoSystem:
|
||
===============
|
||
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
|
||
Operator designates any gateway system that can communicate to detect
|
||
current network environment.
|
||
System sends ICMP packet to the designated gateway system periodically.
|
||
If the system doesn't receive ping reply packet within any interval,
|
||
operator recognizes that the system can't communicate any more
|
||
because of some problems of the system.
|
||
510: autoResetNoPingReplyLoss:
|
||
===============
|
||
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
|
||
less than the configured free memory size or not.
|
||
Periodically, free memory size is checked to confirm system availability.
|
||
512: autoResetNoMemoryLeakDetect:
|
||
===============
|
||
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
|
||
602: arulePacketDropRelease:
|
||
===============
|
||
620: bME1CardNoDetect:
|
||
621: clearBME1CardNoDetect:
|
||
===============
|
||
622: bME1CardAFEerror:
|
||
623: clearBME1CardAFEerror:
|
||
===============
|
||
624: bME1CardIFEerror:
|
||
625: clearBME1CardIFEerror:
|
||
===============
|
||
626: bME1CardFWerror:
|
||
627: clearBME1CardFWerror:
|
||
===============
|
||
628: bME1CardPROVerror:
|
||
629: clearBME1CardPROVerror:
|
||
===============
|
||
630: bME1CrashDetect:
|
||
631: clearBME1CrashDetect:
|
||
===============
|
||
632: bME2CardNoDetect:
|
||
633: clearBME2CardNoDetect:
|
||
===============
|
||
634: bME2CardAFEerror:
|
||
635: clearBME2CardAFEerror:
|
||
===============
|
||
636: bME2CardIFEerror:
|
||
637: clearBME2CardIFEerror:
|
||
===============
|
||
638: bME2CardFWerror:
|
||
639: clearBME2CardFWerror:
|
||
===============
|
||
640: bME2CardPROVerror:
|
||
641: clearBME2CardPROVerror:
|
||
===============
|
||
642: bME2CrashDetect:
|
||
643: clearBME2CrashDetect:
|
||
===============
|
||
644: bME3CardNoDetect:
|
||
645: clearBME3CardNoDetect:
|
||
===============
|
||
646: bME3CardAFEerror:
|
||
647: clearBME3CardAFEerror:
|
||
===============
|
||
648: bME3CardIFEerror:
|
||
649: clearBME3CardIFEerror:
|
||
===============
|
||
650: bME3CardFWerror:
|
||
651: clearBME3CardFWerror:
|
||
===============
|
||
652: bME3CardPROVerror:
|
||
653: clearBME3CardPROVerror:
|
||
===============
|
||
654: bME3CrashDetect:
|
||
655: clearBME3CrashDetect:
|
||
===============
|
||
656: powerFromBattery:
|
||
657: clearPowerFromBattery:
|
||
===============
|
||
658: invalidBatteryStatus:
|
||
659: clearInvalidBatteryStatus:
|
||
===============
|
||
660: batteryChargeLow:
|
||
661: clearBatteryChargeLow:
|
||
===============
|
||
662: batteryNotPresent:
|
||
663: clearBatteryNotPresent:
|
||
===============
|
||
664: voltageLow:
|
||
665: clearVoltageLow:
|
||
===============
|
||
666: tempOverThreshold:
|
||
667: clearTempOverThreshold:
|
||
===============
|
||
668: tempUnderThreshold:
|
||
669: clearTempUnderThreshold:
|
||
===============
|
||
670: cpuOverThreshold:
|
||
671: clearCpuOverThreshold:
|
||
===============
|
||
672: trafficOverload:
|
||
673: clearTrafficOverload:
|
||
===============
|
||
674: gEPONModuleNotDetect:
|
||
675: clearGEPONModuleNotDetect:
|
||
===============
|
||
676: gEPONPortOperationDown:
|
||
677: clearGEPONPortOperationDown:
|
||
===============
|
||
678: gEPONNoIncomingTraffic:
|
||
679: clearGEPONNoIncomingTraffic:
|
||
===============
|
||
680: processCrashDetect:
|
||
681: clearProcessCrashDetect:
|
||
===============
|
||
682: memoryLeakDetect:
|
||
683: clearMemoryLeakDetect:
|
||
===============
|
||
684: memoryCorrupDetect:
|
||
685: clearMemoryCorrupDetect:
|
||
===============
|
||
686: memoryLowDetect:
|
||
687: clearMemoryLowDetect:
|
||
===============
|
||
688: dataLineerror:
|
||
689: clearDataLineerror:
|
||
===============
|
||
690: addressLineerror:
|
||
691: clearAddressLineerror:
|
||
===============
|
||
692: chipsetNotDetcet:
|
||
693: clearChipsetNotDetcet:
|
||
===============
|
||
694: pciBuserror:
|
||
695: clearPciBuserror:
|
||
===============
|
||
696: securityAdminConnect:
|
||
697: clearSecurityAdminConnect:
|
||
===============
|
||
698: oNUPowerDown:
|
||
699: clearONUPowerDown:
|
||
===============
|
||
700: oNUNotRegister:
|
||
701: clearONUNotRegister:
|
||
===============
|
||
702: oNTOpticPre:
|
||
703: clearONTOpticPre:
|
||
===============
|
||
800: switchoverInitiated:
|
||
===============
|
||
801: switchoverDone:
|
||
===============
|
||
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
|
||
===============
|
||
901: gponNoAuthCBU: To detect no auth CBU is detected.
|
||
902: gponDuplicateONU: To detect ONU is duplicated.
|
||
903: gponDyingGasp: To detect dying GASP is detected.
|
||
904: gponUpgradeComplete: To detect upgrade complete is detected.
|
||
905: gponDeregistered: To detect whether deregistered is detected or not.
|
||
906: gponRegistered:
|
||
907: gponRogueOnu: To detect rogue ONU is detected
|
||
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
|
||
909: clearGponOnuBetteryEvent:
|
||
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
|
||
911: gponTransceiverChanged: To detect transceiver is changed.
|
||
912: gponOltLosOn: To detect whether OLT LOS is on or off
|
||
913: gponOltLosOff:
|
||
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
|
||
915: gponOltLosiOff:
|
||
916: gponDyingGaspOn: To detect whether dying GASP is on or off
|
||
917: gponDyingGaspOff:
|
||
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
|
||
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
|
||
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
|
||
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
|
||
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
|
||
923: gponOnuTemperatureHighFallThreshold:
|
||
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
|
||
925: gponOnuTemperatureLowFallThreshold:
|
||
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
|
||
927: gponOnuCpuFallThreshold:
|
||
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
|
||
929: gponOnuMemoryFallThreshold:
|
||
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
|
||
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
|
||
932: gponOnuRxOpticLowThreshAlarmOff:
|
||
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
|
||
934: gponOnuRxOpticHighThreshAlarmOff:
|
||
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
|
||
936: gponOltLOFIOff:
|
||
937: gponOltDOWOn: To detect whether OLT DOW is on or off
|
||
938: gponOltDOWOff:
|
||
939: gponOltSFOn: To detect whether OLT SF is on or off
|
||
940: gponOltSFOff:
|
||
941: gponOltSDOn: To detect whether OLT SD is on or off
|
||
942: gponOltSDOff:
|
||
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
|
||
944: gponOltLCDGIOff:
|
||
945: gponOltRDOn: To detect whether OLT RD is on or off
|
||
946: gponOltRDOff:
|
||
947: gponOltSUFOn: To detect whether OLT SUF is on or off
|
||
948: gponOltSUFOff:
|
||
949: gponOltLOAOn: To detect whether OLT LOA is on or off
|
||
950: gponOltLOAOff:
|
||
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
|
||
952: gponOltLOAMIOff:
|
||
953: gponOltMEMOn: To detect whether OLT MEM is on or off
|
||
954: gponOltMEMOff:
|
||
955: gponOltPEEOn: To detect whether OLT PEE is on or off
|
||
956: gponOltPEEOff:
|
||
957: gponOltPSTOn: To detect whether OLT PST is on or off
|
||
958: gponOltPSTOff:
|
||
959: gponOltERROn: To detect whether OLT ERR is on or off
|
||
960: gponOltERROff:
|
||
961: gponOltREIOn: To detect whether OLT REI is on or off
|
||
962: gponOltREIOff:
|
||
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
|
||
964: gponAntiSpoofingDupPortOff:
|
||
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
|
||
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
|
||
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
|
||
968: gponOnuPortOpticModuleInstall:
|
||
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
|
||
970: gponOnuOMCCProblemCleared:
|
||
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
|
||
972: gponOltFixedTcontAlarmOff:
|
||
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
|
||
974: gponOltDynamicTcontAlarmOff:
|
||
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
|
||
976: gponOltPortCountAlarmOff:
|
||
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
|
||
978: gponOltCableDownAlarmOff:
|
||
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
|
||
980: gponOltDeactiveMonitorAlarmOff:
|
||
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
|
||
982: gponOltDfiOff:
|
||
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
|
||
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
|
||
986: gponOnuPortOperStatusUp::
|
||
===============
|
||
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
|
||
1102: emLogDefectCPUHighUnder:
|
||
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
|
||
1104: emLogTemperHighUnder:
|
||
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
|
||
1106: emLogTemperLowOver:
|
||
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
|
||
1108: emLogMemLowOver:
|
||
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
|
||
1110: emLogFanFailCleared:
|
||
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
|
||
1112: emLogPhyCRCFailCleared:
|
||
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
|
||
1114: emLogPhyDetectFailCleared:
|
||
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
|
||
1116: emLogSFUMateInitFailCleared:
|
||
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
|
||
1118: emLogDaemonHealthBadCleared:
|
||
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
|
||
1120: emLogGPIURavenLinkDownCleared:
|
||
===============
|
||
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
|
||
1152: slotNosUpgradeEnd:
|
||
===============
|
||
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
|
||
1332: gponOnuAniVoltageLowThreshAlarmOff:
|
||
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
|
||
1334: gponOnuAniVoltageHighThreshAlarmOff:
|
||
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
|
||
1336: gponOnuAniTemperatureLowThreshAlarmOff:
|
||
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
|
||
1338: gponOnuAniTemperatureHighThreshAlarmOff:
|
||
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
|
||
1340: gponOnuAniTxBiasLowThreshAlarmOff:
|
||
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
|
||
1342: gponOnuAniTxBiasHighThreshAlarmOff:
|
||
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
|
||
1344: gponOnuAniTxpowerLowThreshAlarmOff:
|
||
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
|
||
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
|
||
::= { sleAlarmHistoryEntry 2 }
|
||
|
||
|
||
sleAlarmHistorySeverity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
warning(4),
|
||
intermediate(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleAlarmHistoryEntry 3 }
|
||
|
||
|
||
sleAlarmHistoryText OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Textual description of specific problem reported by alarming.
|
||
To be discussed: Option is to define an alarm for every problem
|
||
"
|
||
::= { sleAlarmHistoryEntry 4 }
|
||
|
||
|
||
sleAlarmHistoryTime OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The severity of alarm. "
|
||
::= { sleAlarmHistoryEntry 5 }
|
||
|
||
|
||
sleAlarmHistorySeqNum OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sequence number for the alarm synchronization.
|
||
This value has a number to be used for the next alarm trap."
|
||
::= { sleAlarmHistoryEntry 6 }
|
||
|
||
|
||
sleAlarmHistoryPairType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
pair(0),
|
||
mono(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The type is whether alarm trap is pair or mono."
|
||
::= { sleAlarmHistoryEntry 7 }
|
||
|
||
|
||
sleAlarmHistoryControl OBJECT IDENTIFIER ::= { sleAlarmHistory 2 }
|
||
|
||
|
||
sleAlarmHistoryControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER { clearAlarmHistory(1) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" This attribute identifies the control commands.
|
||
updateAlarmList:
|
||
the NE updates entries of alarms in the sleAlarmListTable
|
||
after having changed alarm severities of alarms
|
||
(due to change profile pointers in
|
||
managed entities or after modification of alarm severities
|
||
in profiles). This command should be applied once after having
|
||
finisled modifications of severties.
|
||
modifyAlarmSeverity:
|
||
modifies the severity of an alarm in specific profile.
|
||
createAlarmSeverityProfile:
|
||
creates a new profile with default severities.
|
||
The severities then have to be modified with command changeAlarmSeverity.
|
||
deleteAlarmSeverityProfile:
|
||
deletes a profile. Profile 1 is not allowed to be deleted.
|
||
|
||
Notifications : none "
|
||
::= { sleAlarmHistoryControl 1 }
|
||
|
||
|
||
sleAlarmHistoryControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleAlarmHistoryControl 2 }
|
||
|
||
|
||
sleAlarmHistoryControlTimer OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleAlarmHistoryControl 3 }
|
||
|
||
|
||
sleAlarmHistoryControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleAlarmHistoryControl 4 }
|
||
|
||
|
||
sleAlarmHistoryControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleAlarmHistoryControl 5 }
|
||
|
||
|
||
sleAlarmHistoryNotification OBJECT IDENTIFIER ::= { sleAlarmHistory 3 }
|
||
|
||
|
||
sleAlarmHistoryCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmHistoryControlRequest, sleAlarmHistoryControlTimeStamp, sleAlarmHistoryControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmHistoryNotification 1 }
|
||
|
||
|
||
sleEfmOam OBJECT IDENTIFIER ::= { sleFaultMgmt 5 }
|
||
|
||
|
||
sleEfmOamTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleEfmOamEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOam 1 }
|
||
|
||
|
||
sleEfmOamEntry OBJECT-TYPE
|
||
SYNTAX SleEfmOamEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleOamPortIndex }
|
||
::= { sleEfmOamTable 1 }
|
||
|
||
|
||
SleEfmOamEntry ::=
|
||
SEQUENCE {
|
||
sleOamPortIndex
|
||
INTEGER,
|
||
sleOamMuxAction
|
||
INTEGER,
|
||
sleOamParAction
|
||
INTEGER,
|
||
sleOamAdminState
|
||
INTEGER,
|
||
sleOamMode
|
||
INTEGER,
|
||
sleOamUnidirectionMode
|
||
INTEGER,
|
||
sleOamFunctionsSupported
|
||
BITS,
|
||
sleOamPeerStatus
|
||
INTEGER,
|
||
sleOamPeerMacAddress
|
||
MacAddress,
|
||
sleOamPeerMode
|
||
INTEGER,
|
||
sleOamPeerFunctionsSupported
|
||
BITS,
|
||
sleOamRemLoopback
|
||
INTEGER,
|
||
sleOamRemLoopbackCnt
|
||
INTEGER,
|
||
sleOamLm
|
||
INTEGER,
|
||
sleOamLmAction
|
||
INTEGER,
|
||
sleOamLmFrameWindow
|
||
INTEGER,
|
||
sleOamLmFrameThresh
|
||
INTEGER,
|
||
sleOamLmFrameTotal
|
||
Counter64,
|
||
sleOamLmFramePeriodWindow
|
||
Integer32,
|
||
sleOamLmFramePeriodThresh
|
||
Integer32,
|
||
sleOamLmFramePeriodTotal
|
||
Counter64,
|
||
sleOamLmFrameSecondSummaryWindow
|
||
Integer32,
|
||
sleOamLmFrameSecondSummaryThresh
|
||
Integer32,
|
||
sleOamLmFrameSecondSummaryTotal
|
||
Counter64,
|
||
sleOamLmSymbolPeriodWindow
|
||
INTEGER,
|
||
sleOamLmSymbolPeriodThresh
|
||
INTEGER,
|
||
sleOamLmSymbolPeriodTotal
|
||
Counter64,
|
||
sleOamLmRemSeqNum
|
||
Integer32,
|
||
sleOamLmRemFrameLength
|
||
Integer32,
|
||
sleOamLmRemFrameTimeStamp
|
||
TimeTicks,
|
||
sleOamLmRemFrameWindow
|
||
Integer32,
|
||
sleOamLmRemFrameThresh
|
||
Integer32,
|
||
sleOamLmRemFrameErrors
|
||
Integer32,
|
||
sleOamLmRemFrameErrorRunTotal
|
||
Counter64,
|
||
sleOamLmRemFrameEventRunTotal
|
||
Integer32,
|
||
sleOamLmRemFramePeriodLength
|
||
Integer32,
|
||
sleOamLmRemFramePeriodTimeStamp
|
||
TimeTicks,
|
||
sleOamLmRemFramePeriodWindow
|
||
Integer32,
|
||
sleOamLmRemFramePeriodThresh
|
||
Integer32,
|
||
sleOamLmRemFramePeriodErrors
|
||
Integer32,
|
||
sleOamLmRemFramePeriodErrorRunTotal
|
||
Counter64,
|
||
sleOamLmRemFramePeriodEventRunTotal
|
||
Integer32,
|
||
sleOamLmRemFrameSecondSummaryLength
|
||
Integer32,
|
||
sleOamLmRemFrameSecondSummaryTimeStamp
|
||
TimeTicks,
|
||
sleOamLmRemFrameSecondSummaryWindow
|
||
Integer32,
|
||
sleOamLmRemFrameSecondSummaryThresh
|
||
Integer32,
|
||
sleOamLmRemFrameSecondSummaryErrors
|
||
Integer32,
|
||
sleOamLmRemFrameSecondSummaryErrorRunTotal
|
||
Integer32,
|
||
sleOamLmRemFrameSecondSummaryEventRunTotal
|
||
Integer32,
|
||
sleOamLmRemSymbolPeriodLength
|
||
Integer32,
|
||
sleOamLmRemSymbolPeriodTimeStamp
|
||
TimeTicks,
|
||
sleOamLmRemSymbolPeriodWindow
|
||
Counter64,
|
||
sleOamLmRemSymbolPeriodThresh
|
||
Counter64,
|
||
sleOamLmRemSymbolPeriodErrors
|
||
Counter64,
|
||
sleOamLmRemSymbolPeriodErrorRunTotal
|
||
Counter64,
|
||
sleOamLmRemSymbolPeriodEventRunTotal
|
||
Counter64
|
||
}
|
||
|
||
sleOamPortIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOamEntry 1 }
|
||
|
||
|
||
sleOamMuxAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
fwd(1),
|
||
discard(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value governs the flow of frames from
|
||
the MAC client to the Muliplexer function."
|
||
::= { sleEfmOamEntry 2 }
|
||
|
||
|
||
sleOamParAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
fwd(1),
|
||
lb(2),
|
||
discard(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value governs the flow of non-OAMPDUs
|
||
within the Parser function."
|
||
::= { sleEfmOamEntry 3 }
|
||
|
||
|
||
sleOamAdminState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object is used to provision the default
|
||
administrative OAM mode for this interface."
|
||
::= { sleEfmOamEntry 4 }
|
||
|
||
|
||
sleOamMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
passive(0),
|
||
active(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object configures the mode of OAM
|
||
operation for this Ethernet like interface."
|
||
::= { sleEfmOamEntry 5 }
|
||
|
||
|
||
sleOamUnidirectionMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
notAvaliable(-2),
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOamEntry 6 }
|
||
|
||
|
||
sleOamFunctionsSupported OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
unidirectionalSupport(0),
|
||
loopbackSupport(1),
|
||
eventSupport(2),
|
||
variableSupport(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The OAM functions supported on this
|
||
Ethernet like interface."
|
||
::= { sleEfmOamEntry 7 }
|
||
|
||
|
||
sleOamPeerStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
inactive(0),
|
||
active(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates whether the information
|
||
in this row should be considered valid."
|
||
::= { sleEfmOamEntry 8 }
|
||
|
||
|
||
sleOamPeerMacAddress OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MAC address of the peer OAM entity."
|
||
::= { sleEfmOamEntry 9 }
|
||
|
||
|
||
sleOamPeerMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
passive(0),
|
||
active(1),
|
||
unknown(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The mode Info of the OAM peer as reflected
|
||
in the latest Information OAMPDU received with
|
||
a Local Information TLV."
|
||
::= { sleEfmOamEntry 10 }
|
||
|
||
|
||
sleOamPeerFunctionsSupported OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
unidirectionalSupport(0),
|
||
loopbackSupport(1),
|
||
eventSupport(2),
|
||
variableSupport(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The OAM functions supported on this
|
||
Ethernet like interface."
|
||
::= { sleEfmOamEntry 11 }
|
||
|
||
|
||
sleOamRemLoopback OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOamEntry 12 }
|
||
|
||
|
||
sleOamRemLoopbackCnt OBJECT-TYPE
|
||
SYNTAX INTEGER (1..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of test Packet"
|
||
::= { sleEfmOamEntry 13 }
|
||
|
||
|
||
sleOamLm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value indicates whether Link-Monitor supports or not for port index."
|
||
::= { sleEfmOamEntry 14 }
|
||
|
||
|
||
sleOamLmAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
syslog(0),
|
||
snmpTrap(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Action of Link-Monitor for port index."
|
||
::= { sleEfmOamEntry 15 }
|
||
|
||
|
||
sleOamLmFrameWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (10..600)
|
||
UNITS "100 ms"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window size of Errored Frame.
|
||
Default : 10, Unit : 100ms
|
||
"
|
||
::= { sleEfmOamEntry 16 }
|
||
|
||
|
||
sleOamLmFrameThresh OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of Errored Frame.
|
||
Default: 1
|
||
"
|
||
::= { sleEfmOamEntry 17 }
|
||
|
||
|
||
sleOamLmFrameTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total Count of Errored Frame"
|
||
::= { sleEfmOamEntry 18 }
|
||
|
||
|
||
sleOamLmFramePeriodWindow OBJECT-TYPE
|
||
SYNTAX Integer32 (1000..200000000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is size of Errored Period Window.
|
||
Default : 1000000 frames
|
||
"
|
||
::= { sleEfmOamEntry 19 }
|
||
|
||
|
||
sleOamLmFramePeriodThresh OBJECT-TYPE
|
||
SYNTAX Integer32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is size of Errored Period Threshold.
|
||
Default : 10
|
||
"
|
||
::= { sleEfmOamEntry 20 }
|
||
|
||
|
||
sleOamLmFramePeriodTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total Count of Errored Period Frame"
|
||
::= { sleEfmOamEntry 21 }
|
||
|
||
|
||
sleOamLmFrameSecondSummaryWindow OBJECT-TYPE
|
||
SYNTAX Integer32 (10..900)
|
||
UNITS "seconds"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window size of errored frame in a second
|
||
Default : 60 secs
|
||
"
|
||
::= { sleEfmOamEntry 22 }
|
||
|
||
|
||
sleOamLmFrameSecondSummaryThresh OBJECT-TYPE
|
||
SYNTAX Integer32 (0..900)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of errored frame in a second
|
||
Default: 1
|
||
"
|
||
::= { sleEfmOamEntry 23 }
|
||
|
||
|
||
sleOamLmFrameSecondSummaryTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total Count of Errored Frame Second"
|
||
::= { sleEfmOamEntry 24 }
|
||
|
||
|
||
sleOamLmSymbolPeriodWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1000000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the window size of symbol errors.
|
||
Default: 625 millions, Unit: 1 million
|
||
"
|
||
::= { sleEfmOamEntry 25 }
|
||
|
||
|
||
sleOamLmSymbolPeriodThresh OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of symbol errors
|
||
Default : 1
|
||
"
|
||
::= { sleEfmOamEntry 26 }
|
||
|
||
|
||
sleOamLmSymbolPeriodTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total Count of Symbol errors"
|
||
::= { sleEfmOamEntry 27 }
|
||
|
||
|
||
sleOamLmRemSeqNum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Sequence Number for event"
|
||
::= { sleEfmOamEntry 28 }
|
||
|
||
|
||
sleOamLmRemFrameLength OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Length of Errored Frame"
|
||
::= { sleEfmOamEntry 29 }
|
||
|
||
|
||
sleOamLmRemFrameTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the TimeStamp of Errored Frame"
|
||
::= { sleEfmOamEntry 30 }
|
||
|
||
|
||
sleOamLmRemFrameWindow OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window Size of Errored Frame"
|
||
::= { sleEfmOamEntry 31 }
|
||
|
||
|
||
sleOamLmRemFrameThresh OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold Size of Errored Frame"
|
||
::= { sleEfmOamEntry 32 }
|
||
|
||
|
||
sleOamLmRemFrameErrors OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Count of Errored Frame"
|
||
::= { sleEfmOamEntry 33 }
|
||
|
||
|
||
sleOamLmRemFrameErrorRunTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Frame"
|
||
::= { sleEfmOamEntry 34 }
|
||
|
||
|
||
sleOamLmRemFrameEventRunTotal OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Frame Event"
|
||
::= { sleEfmOamEntry 35 }
|
||
|
||
|
||
sleOamLmRemFramePeriodLength OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Length of Errored Frame Period"
|
||
::= { sleEfmOamEntry 36 }
|
||
|
||
|
||
sleOamLmRemFramePeriodTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the TimeStamp of Errored Frame Period"
|
||
::= { sleEfmOamEntry 37 }
|
||
|
||
|
||
sleOamLmRemFramePeriodWindow OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window Size of Errored Frame Period"
|
||
::= { sleEfmOamEntry 38 }
|
||
|
||
|
||
sleOamLmRemFramePeriodThresh OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold Size of Errored Frame Period"
|
||
::= { sleEfmOamEntry 39 }
|
||
|
||
|
||
sleOamLmRemFramePeriodErrors OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Count of Errored Frame Period"
|
||
::= { sleEfmOamEntry 40 }
|
||
|
||
|
||
sleOamLmRemFramePeriodErrorRunTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Frame Period"
|
||
::= { sleEfmOamEntry 41 }
|
||
|
||
|
||
sleOamLmRemFramePeriodEventRunTotal OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Frame Period Event"
|
||
::= { sleEfmOamEntry 42 }
|
||
|
||
|
||
sleOamLmRemFrameSecondSummaryLength OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Length of Errored Frame Second Summary"
|
||
::= { sleEfmOamEntry 43 }
|
||
|
||
|
||
sleOamLmRemFrameSecondSummaryTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the TimeStamp of Errored Frame Second Summary"
|
||
::= { sleEfmOamEntry 44 }
|
||
|
||
|
||
sleOamLmRemFrameSecondSummaryWindow OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window size of Errored Frame Second Summary"
|
||
::= { sleEfmOamEntry 45 }
|
||
|
||
|
||
sleOamLmRemFrameSecondSummaryThresh OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of Errored Frame Second Summary"
|
||
::= { sleEfmOamEntry 46 }
|
||
|
||
|
||
sleOamLmRemFrameSecondSummaryErrors OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Count of Errored Frame Second Summary"
|
||
::= { sleEfmOamEntry 47 }
|
||
|
||
|
||
sleOamLmRemFrameSecondSummaryErrorRunTotal OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Frame Second Summary"
|
||
::= { sleEfmOamEntry 48 }
|
||
|
||
|
||
sleOamLmRemFrameSecondSummaryEventRunTotal OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Frame Second Summary Event"
|
||
::= { sleEfmOamEntry 49 }
|
||
|
||
|
||
sleOamLmRemSymbolPeriodLength OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Length of Errored Symbols"
|
||
::= { sleEfmOamEntry 50 }
|
||
|
||
|
||
sleOamLmRemSymbolPeriodTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the TimeStamp of Errored Symbols"
|
||
::= { sleEfmOamEntry 51 }
|
||
|
||
|
||
sleOamLmRemSymbolPeriodWindow OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window size of Errored Symbols"
|
||
::= { sleEfmOamEntry 52 }
|
||
|
||
|
||
sleOamLmRemSymbolPeriodThresh OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of Errored Symbols"
|
||
::= { sleEfmOamEntry 53 }
|
||
|
||
|
||
sleOamLmRemSymbolPeriodErrors OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Count of Errored Symbols"
|
||
::= { sleEfmOamEntry 54 }
|
||
|
||
|
||
sleOamLmRemSymbolPeriodErrorRunTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Symbols"
|
||
::= { sleEfmOamEntry 55 }
|
||
|
||
|
||
sleOamLmRemSymbolPeriodEventRunTotal OBJECT-TYPE
|
||
SYNTAX Counter64
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Total Count of Errored Symbols Event"
|
||
::= { sleEfmOamEntry 56 }
|
||
|
||
|
||
sleEfmOamControl OBJECT IDENTIFIER ::= { sleEfmOam 2 }
|
||
|
||
|
||
sleOamControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setEfmOamPortProfile(1),
|
||
setEfmOamPortRemLoopback(2),
|
||
setEfmOamPortLinkMonitor(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MIB object for the user command.."
|
||
::= { sleEfmOamControl 1 }
|
||
|
||
|
||
sleOamControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Describes the status of a user command group,
|
||
used for block commands while a command execution in process."
|
||
::= { sleEfmOamControl 2 }
|
||
|
||
|
||
sleOamControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum command duration time in case of long running"
|
||
::= { sleEfmOamControl 3 }
|
||
|
||
|
||
sleOamControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeStamp
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Time stamp attribute set at end of command."
|
||
::= { sleEfmOamControl 4 }
|
||
|
||
|
||
sleOamControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Command result attribute"
|
||
::= { sleEfmOamControl 5 }
|
||
|
||
|
||
sleOamControlIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOamControl 6 }
|
||
|
||
|
||
sleOamControlPortAdminState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object is used to provision the default
|
||
administrative OAM mode for this interface."
|
||
::= { sleEfmOamControl 7 }
|
||
|
||
|
||
sleOamControlPortMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
passive(0),
|
||
active(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object configures the mode of OAM
|
||
operation for this Ethernet like interface."
|
||
::= { sleEfmOamControl 8 }
|
||
|
||
|
||
sleOamControlPortUnidirectionMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
notAvaliable(-2),
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOamControl 9 }
|
||
|
||
|
||
sleOamControlPortRemLoopback OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1),
|
||
start(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value indicates an optional data link
|
||
layer frame-level loopback mode, which is
|
||
controlled remotely."
|
||
::= { sleEfmOamControl 10 }
|
||
|
||
|
||
sleOamControlRemLoopbackPkCnt OBJECT-TYPE
|
||
SYNTAX Integer32 (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of test Packet"
|
||
::= { sleEfmOamControl 11 }
|
||
|
||
|
||
sleOamControlLm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value indicates whether Link-Monitor supports or not for port index."
|
||
::= { sleEfmOamControl 12 }
|
||
|
||
|
||
sleOamControlLmAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
syslog(0),
|
||
snmpTrap(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Action of Link-Monitor for port index."
|
||
::= { sleEfmOamControl 13 }
|
||
|
||
|
||
sleOamControlLmFrameWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (10..600)
|
||
UNITS "seconds"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window size of Errored Frame.
|
||
Default : 30 secs
|
||
"
|
||
::= { sleEfmOamControl 14 }
|
||
|
||
|
||
sleOamControlLmFrameThresh OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of Errored Frame.
|
||
Default: 1
|
||
"
|
||
::= { sleEfmOamControl 15 }
|
||
|
||
|
||
sleOamControlLmFramePeriodWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (1000..200000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is size of Errored Period Window.
|
||
Default : 1000000 frames
|
||
"
|
||
::= { sleEfmOamControl 16 }
|
||
|
||
|
||
sleOamControlLmFramePeriodThresh OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is size of Errored Period Threshold.
|
||
Default : 10
|
||
"
|
||
::= { sleEfmOamControl 17 }
|
||
|
||
|
||
sleOamControlLmFrameSecondSummaryWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (10..900)
|
||
UNITS "seconds"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Window size of errored frame in a second
|
||
Default : 60 secs
|
||
"
|
||
::= { sleEfmOamControl 18 }
|
||
|
||
|
||
sleOamControlLmFrameSecondSummaryThresh OBJECT-TYPE
|
||
SYNTAX INTEGER (0..900)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of errored frame in a second
|
||
Default: 1
|
||
"
|
||
::= { sleEfmOamControl 19 }
|
||
|
||
|
||
sleOamControlLmSymbolPeriodWindow OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1000000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the window size of symbol errors.
|
||
Default: 625 millions, Unit: 1 million
|
||
"
|
||
::= { sleEfmOamControl 20 }
|
||
|
||
|
||
sleOamControlLmSymbolPeriodThresh OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is the Threshold size of symbol errors
|
||
Default : 1
|
||
|
||
"
|
||
::= { sleEfmOamControl 21 }
|
||
|
||
|
||
sleEfmOamNotification OBJECT IDENTIFIER ::= { sleEfmOam 3 }
|
||
|
||
|
||
sleEfmOamPortProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleOamControlReqResult, sleOamControlTimeStamp, sleOamControlRequest, sleOamAdminState, sleOamMode,
|
||
sleOamUnidirectionMode }
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleEfmOamNotification 1 }
|
||
|
||
|
||
sleEfmOamPortRemLoopback NOTIFICATION-TYPE
|
||
OBJECTS { sleOamControlRequest, sleOamControlReqResult, sleOamControlTimeStamp, sleOamRemLoopback, sleOamControlRemLoopbackPkCnt
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOamNotification 2 }
|
||
|
||
|
||
sleEfmOamPortLinkMonitorChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleOamControlRequest, sleOamControlReqResult, sleOamControlTimeStamp, sleOamLmFramePeriodThresh, sleOamLmFramePeriodWindow,
|
||
sleOamLmFrameThresh, sleOamLmFrameWindow, sleOamLmAction, sleOamLmSymbolPeriodThresh, sleOamLmSymbolPeriodWindow,
|
||
sleOamLmFrameSecondSummaryThresh, sleOamLmFrameSecondSummaryWindow, sleOamLm, sleOamPortIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEfmOamNotification 3 }
|
||
|
||
|
||
sleAdvaSystem OBJECT IDENTIFIER ::= { sleFaultMgmt 6 }
|
||
|
||
|
||
sleAdvaSystemTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAdvaSystemEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystem 1 }
|
||
|
||
|
||
sleAdvaSystemEntry OBJECT-TYPE
|
||
SYNTAX SleAdvaSystemEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleOamPortIndex }
|
||
::= { sleAdvaSystemTable 1 }
|
||
|
||
|
||
SleAdvaSystemEntry ::=
|
||
SEQUENCE {
|
||
sleAdvaFSPOperationMode
|
||
INTEGER,
|
||
sleAdvaActiveNetworkInterface
|
||
INTEGER,
|
||
sleAdvaForceNetworkInterface
|
||
INTEGER,
|
||
sleAdvaReportingInterval
|
||
INTEGER,
|
||
sleAdvaNEMIFitted
|
||
INTEGER,
|
||
sleAdvaForceReset
|
||
INTEGER,
|
||
sleAdvaManagerAddress
|
||
IpAddress,
|
||
sleAdvaMinRailVoltageThreshold
|
||
INTEGER,
|
||
sleAdvaMaxRailVoltageThreshold
|
||
INTEGER,
|
||
sleAdvaTemperatureThreshold
|
||
INTEGER,
|
||
sleAdvaPartNumber
|
||
OCTET STRING,
|
||
sleAdvaSerialNumber
|
||
OCTET STRING,
|
||
sleAdvaFirmwareVersion
|
||
OCTET STRING,
|
||
sleAdvaFPGAVersion
|
||
OCTET STRING,
|
||
sleAdvaHardwareRevision
|
||
OCTET STRING,
|
||
sleAdvaCLEICode
|
||
OCTET STRING,
|
||
sleAdvaTemperature
|
||
INTEGER,
|
||
sleAdvaRailVoltage
|
||
INTEGER,
|
||
sleAdvaPSUStates
|
||
INTEGER,
|
||
sleAdvaPSUType
|
||
INTEGER,
|
||
sleAdvaFansFitted
|
||
INTEGER,
|
||
sleAdvaFanState
|
||
INTEGER,
|
||
sleAdvaTransmitMode
|
||
INTEGER
|
||
}
|
||
|
||
sleAdvaFSPOperationMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
master(1),
|
||
slave(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mode in which the FSP 150 is to operate"
|
||
::= { sleAdvaSystemEntry 1 }
|
||
|
||
|
||
sleAdvaActiveNetworkInterface OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
both(0),
|
||
portA(1),
|
||
portB(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Which of the network interfaces is the active one"
|
||
::= { sleAdvaSystemEntry 2 }
|
||
|
||
|
||
sleAdvaForceNetworkInterface OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unforced(0),
|
||
forceA(1),
|
||
forceB(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemEntry 3 }
|
||
|
||
|
||
sleAdvaReportingInterval OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Repeat period in 1/10th seconds for Organisation Specific Alarm
|
||
Status OAMPDU. If non-zero and there are any alarms active,
|
||
repeat the last-sent AS after this interval from when it was
|
||
last sent.If zero then only send on changes.As a special action,
|
||
writing zero to this will cause the Alarm Status OAMPDU to be sent (poll)."
|
||
::= { sleAdvaSystemEntry 4 }
|
||
|
||
|
||
sleAdvaNEMIFitted OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicator as to whether a NEMI is fitted."
|
||
::= { sleAdvaSystemEntry 5 }
|
||
|
||
|
||
sleAdvaForceReset OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Writing True (1) causes the system to be reset."
|
||
::= { sleAdvaSystemEntry 6 }
|
||
|
||
|
||
sleAdvaManagerAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The IP address of the Management station monitoring this sytem."
|
||
::= { sleAdvaSystemEntry 7 }
|
||
|
||
|
||
sleAdvaMinRailVoltageThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Threshold in mV below which the Voltage low alarm will be
|
||
activated. (Alarm Configuration)"
|
||
::= { sleAdvaSystemEntry 8 }
|
||
|
||
|
||
sleAdvaMaxRailVoltageThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Threshold in mV above which the Voltage high alarm will be activated.
|
||
(Alarm Configuration)"
|
||
::= { sleAdvaSystemEntry 9 }
|
||
|
||
|
||
sleAdvaTemperatureThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Threshold in C above which the Temperature alarm will be activated. (Alarm Configuration)"
|
||
::= { sleAdvaSystemEntry 10 }
|
||
|
||
|
||
sleAdvaPartNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Part number for the chassis. (Chassis)"
|
||
::= { sleAdvaSystemEntry 11 }
|
||
|
||
|
||
sleAdvaSerialNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Serial number for the chassis. (Chassis)"
|
||
::= { sleAdvaSystemEntry 12 }
|
||
|
||
|
||
sleAdvaFirmwareVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Firmware version for the chassis. (Chassis)
|
||
(0-length string if unknown)."
|
||
::= { sleAdvaSystemEntry 13 }
|
||
|
||
|
||
sleAdvaFPGAVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"FPGA version for the chassis. (Chassis)
|
||
(0-length string if unknown)."
|
||
::= { sleAdvaSystemEntry 14 }
|
||
|
||
|
||
sleAdvaHardwareRevision OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..4))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Hardware revision for the chassis.
|
||
(Chassis)(0-length string if unknown)."
|
||
::= { sleAdvaSystemEntry 15 }
|
||
|
||
|
||
sleAdvaCLEICode OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"CLEI for the chassis. (Chassis)"
|
||
::= { sleAdvaSystemEntry 16 }
|
||
|
||
|
||
sleAdvaTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current chassis temperature in degrees C. (Chassis)"
|
||
::= { sleAdvaSystemEntry 17 }
|
||
|
||
|
||
sleAdvaRailVoltage OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current DC power rail voltage (mV). (Chassis)"
|
||
::= { sleAdvaSystemEntry 18 }
|
||
|
||
|
||
sleAdvaPSUStates OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Bit-mask representing the state of the PSUs.
|
||
Starting at the LSB, each failed PSU is indicated
|
||
by a bit set to '1'. (Chassis)"
|
||
::= { sleAdvaSystemEntry 19 }
|
||
|
||
|
||
sleAdvaPSUType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ac(1),
|
||
dc(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Type of PSUs fitted. (Chassis)"
|
||
::= { sleAdvaSystemEntry 20 }
|
||
|
||
|
||
sleAdvaFansFitted OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Bit-mask representing which fans are fitted.
|
||
Starting at the LSB, each bit set to '1' indicates a fitted fan.
|
||
Knowledge of which fans ought to be fitted is assumed. (Chassis)"
|
||
::= { sleAdvaSystemEntry 21 }
|
||
|
||
|
||
sleAdvaFanState OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Bit-mask representing the state of the fan.
|
||
Starting at the LSB, each failed fan is indicated by a
|
||
bit set to '1'. (Chassis)"
|
||
::= { sleAdvaSystemEntry 22 }
|
||
|
||
|
||
sleAdvaTransmitMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
halfDuplex(0),
|
||
fullDuplex(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Electrical Interface for remote instance 4"
|
||
::= { sleAdvaSystemEntry 23 }
|
||
|
||
|
||
sleAdvaSystemControl OBJECT IDENTIFIER ::= { sleAdvaSystem 2 }
|
||
|
||
|
||
sleAdvaSystemControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setAdvaSystemProfile(1),
|
||
setAdvaAlarmProfile(2),
|
||
setAdvaElectricalInterface(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MIB object for the user command.."
|
||
::= { sleAdvaSystemControl 1 }
|
||
|
||
|
||
sleAdvaSystemControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Describes the status of a user command group,
|
||
used for block commands while a command execution in process."
|
||
::= { sleAdvaSystemControl 2 }
|
||
|
||
|
||
sleAdvaSystemControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 3 }
|
||
|
||
|
||
sleAdvaSystemControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 4 }
|
||
|
||
|
||
sleAdvaSystemControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 5 }
|
||
|
||
|
||
sleAdvaSystemControlPortIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 6 }
|
||
|
||
|
||
sleAdvaSystemControlFSPOperationMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
master(1),
|
||
save(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 7 }
|
||
|
||
|
||
sleAdvaSystemControlForceNetworkInterface OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unforced(0),
|
||
forceA(1),
|
||
forceB(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 8 }
|
||
|
||
|
||
sleAdvaSystemControlReportingInterval OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 9 }
|
||
|
||
|
||
sleAdvaSystemControlForceReset OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 10 }
|
||
|
||
|
||
sleAdvaSystemControlMinRailVoltageThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 11 }
|
||
|
||
|
||
sleAdvaSystemControlMaxRailVoltageThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 12 }
|
||
|
||
|
||
sleAdvaSystemControlTemperatureThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 13 }
|
||
|
||
|
||
sleAdvaSystemControlTransmitMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
halfDuplex(0),
|
||
fullDuplex(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemControl 14 }
|
||
|
||
|
||
sleAdvaSystemNotification OBJECT IDENTIFIER ::= { sleAdvaSystem 3 }
|
||
|
||
|
||
sleAdvaSystemProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaFSPOperationMode, sleAdvaForceNetworkInterface,
|
||
sleAdvaReportingInterval, sleAdvaForceReset }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemNotification 1 }
|
||
|
||
|
||
sleAdvaAlarmProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaMinRailVoltageThreshold, sleAdvaMaxRailVoltageThreshold,
|
||
sleAdvaTemperatureThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemNotification 2 }
|
||
|
||
|
||
sleAdvaElectricalInterfaceChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaTransmitMode }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaSystemNotification 3 }
|
||
|
||
|
||
sleAdvaGeneral OBJECT IDENTIFIER ::= { sleFaultMgmt 7 }
|
||
|
||
|
||
sleAdvaGeneralTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAdvaGeneralEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneral 1 }
|
||
|
||
|
||
sleAdvaGeneralEntry OBJECT-TYPE
|
||
SYNTAX SleAdvaGeneralEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleOamPortIndex, sleAdvaRemInstance }
|
||
::= { sleAdvaGeneralTable 1 }
|
||
|
||
|
||
SleAdvaGeneralEntry ::=
|
||
SEQUENCE {
|
||
sleAdvaRemInstance
|
||
INTEGER,
|
||
sleAdvaOperationalStatus
|
||
INTEGER,
|
||
sleAdvaLineSpeed
|
||
Integer32,
|
||
sleAdvaMACAddress
|
||
MacAddress,
|
||
sleAdvaConnectorType
|
||
INTEGER,
|
||
sleAdvaAutonegiotation
|
||
INTEGER,
|
||
sleAdvaLinkLossForwarding
|
||
INTEGER,
|
||
sleAdvaAdminState
|
||
INTEGER,
|
||
sleAdvaRemoteInterfaceIndex
|
||
INTEGER,
|
||
sleAdvaUserDefinedString
|
||
OCTET STRING,
|
||
sleAdvaRemoteSignalling
|
||
INTEGER,
|
||
sleAdvaConfiguration
|
||
INTEGER,
|
||
sleAdvaLocalTechnologyAbility
|
||
BITS,
|
||
sleAdvaAdvertisedTechnologyAbility
|
||
BITS,
|
||
sleAdvaReceivedTechnologyAbility
|
||
BITS,
|
||
sleAdvaLocalSectorAbility
|
||
BITS,
|
||
sleAdvaAdvertisedSectorAbility
|
||
BITS,
|
||
sleAdvaReceivedSectorAbility
|
||
BITS,
|
||
sleAdvaDuplexCapabilities
|
||
INTEGER,
|
||
sleAdvaPHYType
|
||
INTEGER,
|
||
sleAdvaPHYTypeList
|
||
BITS,
|
||
sleAdvaMIIDetect
|
||
INTEGER,
|
||
sleAdvaPHYState
|
||
INTEGER,
|
||
sleAdvaGoodFramesTransmitted
|
||
Integer32,
|
||
sleAdvaSingleCollisionFrames
|
||
Integer32,
|
||
sleAdvaMultipleCollisionFrames
|
||
Integer32,
|
||
sleAdvaGoodFramesReceived
|
||
Integer32,
|
||
sleAdvaFCSErrors
|
||
Integer32,
|
||
sleAdvaAlignmentErrors
|
||
Integer32,
|
||
sleAdvaFramesTooLong
|
||
Integer32,
|
||
sleAdvaBytesTransmitted
|
||
Integer32,
|
||
sleAdvaBytesReceived
|
||
Integer32,
|
||
sleAdvaSymbolErrors
|
||
Integer32
|
||
}
|
||
|
||
sleAdvaRemInstance OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralEntry 1 }
|
||
|
||
|
||
sleAdvaOperationalStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
up(1),
|
||
down(2),
|
||
outofservice(3),
|
||
unknown(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"encoding TBD. (General)"
|
||
::= { sleAdvaGeneralEntry 2 }
|
||
|
||
|
||
sleAdvaLineSpeed OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Line speed in kbit/s. (General)"
|
||
::= { sleAdvaGeneralEntry 3 }
|
||
|
||
|
||
sleAdvaMACAddress OBJECT-TYPE
|
||
SYNTAX MacAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Ethernet address of the interface. (General)"
|
||
::= { sleAdvaGeneralEntry 4 }
|
||
|
||
|
||
sleAdvaConnectorType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
sc(1),
|
||
fc(2),
|
||
mu(3),
|
||
rj45(4),
|
||
lu(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"encoding TBD. (General)"
|
||
::= { sleAdvaGeneralEntry 5 }
|
||
|
||
|
||
sleAdvaAutonegiotation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegAdminState. (General)Enabled or disabled. "
|
||
::= { sleAdvaGeneralEntry 6 }
|
||
|
||
|
||
sleAdvaLinkLossForwarding OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"When enabled access interface is brought down, when both network interfaces are down. (General)"
|
||
::= { sleAdvaGeneralEntry 7 }
|
||
|
||
|
||
sleAdvaAdminState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
up(1),
|
||
down(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Whether the interface is available. (General)"
|
||
::= { sleAdvaGeneralEntry 8 }
|
||
|
||
|
||
sleAdvaRemoteInterfaceIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The index of the remote interface the interface is connected to. (General)"
|
||
::= { sleAdvaGeneralEntry 9 }
|
||
|
||
|
||
sleAdvaUserDefinedString OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..32))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User definable string associated with interface. (General)"
|
||
::= { sleAdvaGeneralEntry 10 }
|
||
|
||
|
||
sleAdvaRemoteSignalling OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
detected(1),
|
||
notdetected(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegRemoteSignalling. (AutoNego)"
|
||
::= { sleAdvaGeneralEntry 11 }
|
||
|
||
|
||
sleAdvaConfiguration OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
other(1),
|
||
configuring(2),
|
||
completed(3),
|
||
disabled(4),
|
||
parallelDetectFail(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegConfig.
|
||
(AutoNego)Indicates whether Auto-Negotiation
|
||
signaling is in progress or has completed."
|
||
::= { sleAdvaGeneralEntry 12 }
|
||
|
||
|
||
sleAdvaLocalTechnologyAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
global(0),
|
||
unknown(1),
|
||
base10T(2),
|
||
base10TFD(3),
|
||
base100T4(4),
|
||
base100TX(5),
|
||
base100TXFD(6),
|
||
fdxpause(7),
|
||
fdxapause(8),
|
||
fdxspause(9),
|
||
fdxbpause(10),
|
||
base100T2(11),
|
||
base100T2FD(12),
|
||
base1000X(13),
|
||
base1000XFD(14),
|
||
base1000T(15),
|
||
base1000TFD(16),
|
||
remFault1(17),
|
||
remFault2(18),
|
||
isoEthernet(19)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegLocalTechnologyAbility.
|
||
(AutoNego)This indicates the technology ability of the local device"
|
||
::= { sleAdvaGeneralEntry 13 }
|
||
|
||
|
||
sleAdvaAdvertisedTechnologyAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
global(0),
|
||
unknown(1),
|
||
base10T(2),
|
||
base10TFD(3),
|
||
base100T4(4),
|
||
base100TX(5),
|
||
base100TXFD(6),
|
||
fdxpause(7),
|
||
fdxapause(8),
|
||
fdxspause(9),
|
||
fdxbpause(10),
|
||
base100T2(11),
|
||
base100T2FD(12),
|
||
base1000X(13),
|
||
base1000XFD(14),
|
||
base1000T(15),
|
||
base1000TFD(16),
|
||
remFault1(17),
|
||
remFault2(18),
|
||
isoEthernet(19)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegAdvertisedTechnologyAbility.
|
||
(AutoNego)The advertised technology ability of the local device."
|
||
::= { sleAdvaGeneralEntry 14 }
|
||
|
||
|
||
sleAdvaReceivedTechnologyAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
global(0),
|
||
unknown(1),
|
||
base10T(2),
|
||
base10TFD(3),
|
||
base100T4(4),
|
||
base100TX(5),
|
||
base100TXFD(6),
|
||
fdxpause(7),
|
||
fdxapause(8),
|
||
fdxspause(9),
|
||
fdxbpause(10),
|
||
base100T2(11),
|
||
base100T2FD(12),
|
||
base1000X(13),
|
||
base1000XFD(14),
|
||
base1000T(15),
|
||
base1000TFD(16),
|
||
remFault1(17),
|
||
remFault2(18),
|
||
isoEthernet(19)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegReceivedTechnologyAbility.
|
||
(AutoNego)Indicates the advertised technology ability of the
|
||
remote hardware."
|
||
::= { sleAdvaGeneralEntry 15 }
|
||
|
||
|
||
sleAdvaLocalSectorAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
other(0),
|
||
ethernet(1),
|
||
isoethernet(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)"
|
||
::= { sleAdvaGeneralEntry 16 }
|
||
|
||
|
||
sleAdvaAdvertisedSectorAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
other(0),
|
||
ethernet(1),
|
||
isoethernet(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)"
|
||
::= { sleAdvaGeneralEntry 17 }
|
||
|
||
|
||
sleAdvaReceivedSectorAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
other(0),
|
||
ethernet(1),
|
||
isoethernet(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)"
|
||
::= { sleAdvaGeneralEntry 18 }
|
||
|
||
|
||
sleAdvaDuplexCapabilities OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
halfduplex(0),
|
||
fullduplex(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mandatory package - aMacCapabilities.
|
||
(PHY)The modes of duplex the access interface can support"
|
||
::= { sleAdvaGeneralEntry 19 }
|
||
|
||
|
||
sleAdvaPHYType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
other(1),
|
||
unknown(2),
|
||
none(3),
|
||
base10(4),
|
||
base100T4(5),
|
||
base100X(6),
|
||
base100T2(7),
|
||
base1000X(8),
|
||
base1000T(9)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Basic Package - aPhyType. (PHY)"
|
||
::= { sleAdvaGeneralEntry 20 }
|
||
|
||
|
||
sleAdvaPHYTypeList OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
other(0),
|
||
unknown(1),
|
||
none(2),
|
||
base10(3),
|
||
base100T4(4),
|
||
base100X(5),
|
||
base100T2(6),
|
||
base1000X(7),
|
||
base1000T(8)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Basic Package - aPhyTypeList. (PHY)"
|
||
::= { sleAdvaGeneralEntry 21 }
|
||
|
||
|
||
sleAdvaMIIDetect OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(1),
|
||
nothingConnected(2),
|
||
connected(3),
|
||
absent(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Basic Package - aMIIDetect. (PHY)"
|
||
::= { sleAdvaGeneralEntry 22 }
|
||
|
||
|
||
sleAdvaPHYState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralEntry 23 }
|
||
|
||
|
||
sleAdvaGoodFramesTransmitted OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mandatory package - aFramesTransmittedOK. (PHY)Non-resettable,
|
||
wrapping count of good frames transmitted since OAM enabled."
|
||
::= { sleAdvaGeneralEntry 24 }
|
||
|
||
|
||
sleAdvaSingleCollisionFrames OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mandatory package - aSingleCollisionFrames. (PHY)Non-resettable,
|
||
wrapping count of single collisions since OAM enabled."
|
||
::= { sleAdvaGeneralEntry 25 }
|
||
|
||
|
||
sleAdvaMultipleCollisionFrames OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mandatory package - aMultipleCollisionFrames. (PHY)Non-resettable,
|
||
wrapping count of multiple collisions since OAM enabled."
|
||
::= { sleAdvaGeneralEntry 26 }
|
||
|
||
|
||
sleAdvaGoodFramesReceived OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mandatory package - aFramesReceivedOKNon-resettable,
|
||
wrapping count of good frames received since OAM enabled"
|
||
::= { sleAdvaGeneralEntry 27 }
|
||
|
||
|
||
sleAdvaFCSErrors OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mandatory package - aFrameCheckSequenceErrors. (PHY)Non-resettable,
|
||
wrapping count of frames received with frame check sequence
|
||
error since OAM enabled."
|
||
::= { sleAdvaGeneralEntry 28 }
|
||
|
||
|
||
sleAdvaAlignmentErrors OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mandatory package - aAlignmentErrors. (PHY)Non-resettable,
|
||
wrapping count of frames received with alignment error since OAM enabled."
|
||
::= { sleAdvaGeneralEntry 29 }
|
||
|
||
|
||
sleAdvaFramesTooLong OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"aFrameTooLongErrors. (PHY)Non-resettable, wrapping count
|
||
of frames received longer than maxFrameSize"
|
||
::= { sleAdvaGeneralEntry 30 }
|
||
|
||
|
||
sleAdvaBytesTransmitted OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Non-resettable, wrapping count of bytes transmitted
|
||
since OAM enabled. (PHY)"
|
||
::= { sleAdvaGeneralEntry 31 }
|
||
|
||
|
||
sleAdvaBytesReceived OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Non-resettable, wrapping count of bytes received since OAM enabled. (PHY)"
|
||
::= { sleAdvaGeneralEntry 32 }
|
||
|
||
|
||
sleAdvaSymbolErrors OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Non-resettable, wrapping count of symbol errors received.
|
||
Note: some interfaces may only report one symbol error per frame. (PHY)"
|
||
::= { sleAdvaGeneralEntry 33 }
|
||
|
||
|
||
sleAdvaGeneralControl OBJECT IDENTIFIER ::= { sleAdvaGeneral 2 }
|
||
|
||
|
||
sleAdvaGeneralControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setAdvaGeneralProfile(1),
|
||
setAdvaAutonegProfile(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 1 }
|
||
|
||
|
||
sleAdvaGeneralControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 2 }
|
||
|
||
|
||
sleAdvaGeneralControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 3 }
|
||
|
||
|
||
sleAdvaGeneralControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 4 }
|
||
|
||
|
||
sleAdvaGeneralControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 5 }
|
||
|
||
|
||
sleAdvaGeneralControlPortIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 6 }
|
||
|
||
|
||
sleAdvaGeneralControlRemInstance OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 7 }
|
||
|
||
|
||
sleAdvaGeneralControlLineSpeed OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 8 }
|
||
|
||
|
||
sleAdvaGeneralControlAutonegiotation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 9 }
|
||
|
||
|
||
sleAdvaGeneralControlLinkLossForwarding OBJECT-TYPE
|
||
SYNTAX INTEGER (0..1)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 10 }
|
||
|
||
|
||
sleAdvaGeneralControlUserDefinedString OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..32))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 11 }
|
||
|
||
|
||
sleAdvaGeneralControlAdvertisedTechnologyAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
global(0),
|
||
unknown(1),
|
||
base10T(2),
|
||
base10TFD(3),
|
||
base100T4(4),
|
||
base100TX(5),
|
||
base100TXFD(6),
|
||
fdxpause(7),
|
||
fdxapause(8),
|
||
fdxspause(9),
|
||
fdxbpause(10),
|
||
base100T2(11),
|
||
base100T2FD(12),
|
||
base1000X(13),
|
||
base1000XFD(14),
|
||
base1000T(15),
|
||
base1000TFD(16),
|
||
remFault1(17),
|
||
remFault2(18),
|
||
isoEthernet(19)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 12 }
|
||
|
||
|
||
sleAdvaGeneralControlAdvertisedSectorAbility OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
other(0),
|
||
ethernet(1),
|
||
isoethernet(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralControl 13 }
|
||
|
||
|
||
sleAdvaGeneralNotification OBJECT IDENTIFIER ::= { sleAdvaGeneral 3 }
|
||
|
||
|
||
sleAdvaGeneralProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAdvaGeneralControlRequest, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlTimeStamp, sleAdvaLineSpeed, sleAdvaAutonegiotation,
|
||
sleAdvaLinkLossForwarding, sleAdvaUserDefinedString }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralNotification 1 }
|
||
|
||
|
||
sleAdvaAutonegProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAdvaGeneralControlRequest, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlTimeStamp, sleAdvaAdvertisedTechnologyAbility, sleAdvaAdvertisedSectorAbility
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaGeneralNotification 2 }
|
||
|
||
|
||
sleAdvaModule OBJECT IDENTIFIER ::= { sleFaultMgmt 8 }
|
||
|
||
|
||
sleAdvaModuleTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAdvaModuleEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaModule 1 }
|
||
|
||
|
||
sleAdvaModuleEntry OBJECT-TYPE
|
||
SYNTAX SleAdvaModuleEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleOamPortIndex, sleAdvaRemInstance }
|
||
::= { sleAdvaModuleTable 1 }
|
||
|
||
|
||
SleAdvaModuleEntry ::=
|
||
SEQUENCE {
|
||
sleAdvaModuleType
|
||
INTEGER,
|
||
sleAdvaModulePartNumber
|
||
OCTET STRING,
|
||
sleAdvaModuleSerialNumber
|
||
OCTET STRING,
|
||
sleAdvaModuleFirmwareVersion
|
||
OCTET STRING,
|
||
sleAdvaModuleSoftwareVersion
|
||
OCTET STRING,
|
||
sleAdvaModuleHardwareRevision
|
||
OCTET STRING,
|
||
sleAdvaModuleCLEICode
|
||
OCTET STRING
|
||
}
|
||
|
||
sleAdvaModuleType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
sfp(1),
|
||
nemi(2),
|
||
other(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"encoding TBD"
|
||
::= { sleAdvaModuleEntry 1 }
|
||
|
||
|
||
sleAdvaModulePartNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Part number for the module"
|
||
::= { sleAdvaModuleEntry 2 }
|
||
|
||
|
||
sleAdvaModuleSerialNumber OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Serial number for the module"
|
||
::= { sleAdvaModuleEntry 3 }
|
||
|
||
|
||
sleAdvaModuleFirmwareVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Firmware version for the module."
|
||
::= { sleAdvaModuleEntry 4 }
|
||
|
||
|
||
sleAdvaModuleSoftwareVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Software version for the module"
|
||
::= { sleAdvaModuleEntry 5 }
|
||
|
||
|
||
sleAdvaModuleHardwareRevision OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..4))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Hardware revision for the module."
|
||
::= { sleAdvaModuleEntry 6 }
|
||
|
||
|
||
sleAdvaModuleCLEICode OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..14))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"CLEI for the module."
|
||
::= { sleAdvaModuleEntry 7 }
|
||
|
||
|
||
sleAdvaOptical OBJECT IDENTIFIER ::= { sleFaultMgmt 9 }
|
||
|
||
|
||
sleAdvaOpticalTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAdvaOpticalEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOptical 1 }
|
||
|
||
|
||
sleAdvaOpticalEntry OBJECT-TYPE
|
||
SYNTAX SleAdvaOpticalEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleOamPortIndex, sleAdvaRemInstance }
|
||
::= { sleAdvaOpticalTable 1 }
|
||
|
||
|
||
SleAdvaOpticalEntry ::=
|
||
SEQUENCE {
|
||
sleAdvaOpticalThresholdLevel
|
||
INTEGER,
|
||
sleAdvaLinkLength1
|
||
INTEGER,
|
||
sleAdvaLinkLength2
|
||
INTEGER,
|
||
sleAdvaLinkLength3
|
||
INTEGER,
|
||
sleAdvaLinkLength4
|
||
INTEGER,
|
||
sleAdvaLinkLengthCu
|
||
INTEGER,
|
||
sleAdvaWaveLength
|
||
INTEGER,
|
||
sleAdvaLaserBias
|
||
INTEGER,
|
||
sleAdvaTransmitPower
|
||
INTEGER,
|
||
sleAdvaReceivePower
|
||
INTEGER,
|
||
sleAdvaLaserTxTemperature
|
||
INTEGER
|
||
}
|
||
|
||
sleAdvaOpticalThresholdLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Threshold for the receive power level in dBm below which
|
||
the Interface optical threshold alarm will be activated.Per interface."
|
||
::= { sleAdvaOpticalEntry 1 }
|
||
|
||
|
||
sleAdvaLinkLength1 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Link length supported for 9/125 mm fiber, units of km"
|
||
::= { sleAdvaOpticalEntry 2 }
|
||
|
||
|
||
sleAdvaLinkLength2 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Link length supported for 9/125 mm fiber, units of 100 m"
|
||
::= { sleAdvaOpticalEntry 3 }
|
||
|
||
|
||
sleAdvaLinkLength3 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Link length supported for 50/125 mm fiber, units of 10 m"
|
||
::= { sleAdvaOpticalEntry 4 }
|
||
|
||
|
||
sleAdvaLinkLength4 OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Link length supported for 62.5/125 mm fiber, units of 10 m"
|
||
::= { sleAdvaOpticalEntry 5 }
|
||
|
||
|
||
sleAdvaLinkLengthCu OBJECT-TYPE
|
||
SYNTAX INTEGER (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Link length supported for copper, units of meters"
|
||
::= { sleAdvaOpticalEntry 6 }
|
||
|
||
|
||
sleAdvaWaveLength OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Nominal wavelength in nm"
|
||
::= { sleAdvaOpticalEntry 7 }
|
||
|
||
|
||
sleAdvaLaserBias OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current laser bias current in mA."
|
||
::= { sleAdvaOpticalEntry 8 }
|
||
|
||
|
||
sleAdvaTransmitPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current transmit power in dBm as reported by optics."
|
||
::= { sleAdvaOpticalEntry 9 }
|
||
|
||
|
||
sleAdvaReceivePower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current receive power in dBm as reported by optics. "
|
||
::= { sleAdvaOpticalEntry 10 }
|
||
|
||
|
||
sleAdvaLaserTxTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current temperature of laser in degrees C."
|
||
::= { sleAdvaOpticalEntry 11 }
|
||
|
||
|
||
sleAdvaOpticalControl OBJECT IDENTIFIER ::= { sleAdvaOptical 2 }
|
||
|
||
|
||
sleAdvaOpticalControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER { setAdvaOpticalAlarm(1) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 1 }
|
||
|
||
|
||
sleAdvaOpticalControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 2 }
|
||
|
||
|
||
sleAdvaOpticalControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 3 }
|
||
|
||
|
||
sleAdvaOpticalControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 4 }
|
||
|
||
|
||
sleAdvaOpticalControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 5 }
|
||
|
||
|
||
sleAdvaOpticalControlPortIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 6 }
|
||
|
||
|
||
sleAdvaOpticalControlRemInstance OBJECT-TYPE
|
||
SYNTAX INTEGER (1..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 7 }
|
||
|
||
|
||
sleAdvaOpticalControlThresholdLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalControl 8 }
|
||
|
||
|
||
sleAdvaOpticalNotification OBJECT IDENTIFIER ::= { sleAdvaOptical 3 }
|
||
|
||
|
||
sleAdvaOpticalAlarmChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAdvaOpticalControlRequest, sleAdvaOpticalControlReqResult, sleAdvaOpticalControlTimeStamp, sleAdvaOpticalThresholdLevel }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOpticalNotification 1 }
|
||
|
||
|
||
sleAdvaOam OBJECT IDENTIFIER ::= { sleFaultMgmt 10 }
|
||
|
||
|
||
sleAdvaOamTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAdvaOamEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOam 1 }
|
||
|
||
|
||
sleAdvaOamEntry OBJECT-TYPE
|
||
SYNTAX SleAdvaOamEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleOamPortIndex, sleAdvaRemInstance }
|
||
::= { sleAdvaOamTable 1 }
|
||
|
||
|
||
SleAdvaOamEntry ::=
|
||
SEQUENCE {
|
||
sleAdvaAdminStatus
|
||
INTEGER,
|
||
sleAdvaMode
|
||
INTEGER,
|
||
sleAdvaRemMACAddress
|
||
OCTET STRING,
|
||
sleAdvaRemConfig
|
||
BITS,
|
||
sleAdvaRemPduConfig
|
||
INTEGER,
|
||
sleAdvaLocFlags
|
||
BITS,
|
||
sleAdvaRemFlags
|
||
BITS,
|
||
sleAdvaRemState
|
||
BITS,
|
||
sleAdvaRemVendorOUI
|
||
INTEGER,
|
||
sleAdvaRemDeviceNumber
|
||
INTEGER,
|
||
sleAdvaRemVendorVersion
|
||
INTEGER,
|
||
sleAdvaLocErrSymbolPeriodEventConfig
|
||
INTEGER,
|
||
sleAdvaLocErrFrameEventConfig
|
||
INTEGER,
|
||
sleAdvaLocErrFramePeriodEventConfig
|
||
INTEGER,
|
||
sleAdvaLocErrFrameSecsSummaryEventConfig
|
||
INTEGER,
|
||
sleAdvaPDUsTx
|
||
Integer32,
|
||
sleAdvaPDUsRx
|
||
Integer32,
|
||
sleAdvaUnsupportedCodesRx
|
||
Integer32,
|
||
sleAdvaInfoPDUsTx
|
||
Integer32,
|
||
sleAdvaInfoPDUsRx
|
||
Integer32,
|
||
sleAdvaEventNotificationPDUsTx
|
||
Integer32,
|
||
sleAdvaUniqueEventNotificationPDUsTx
|
||
Integer32,
|
||
sleAdvaDupEventNotificationPDUsTx
|
||
Integer32,
|
||
sleAdvaLoopbackControlPDUsTx
|
||
Integer32,
|
||
sleAdvaLoopbackControlPDUsRx
|
||
Integer32,
|
||
sleAdvaVariableRequestPDUsTx
|
||
Integer32,
|
||
sleAdvaVariableRequestPDUsRx
|
||
Integer32,
|
||
sleAdvaVariableResponsePDUsTx
|
||
Integer32,
|
||
sleAdvaVariableResponsePDUsRx
|
||
Integer32,
|
||
sleAdvaVendorPDUsTx
|
||
Integer32,
|
||
sleAdvaVendorPDUsRx
|
||
Integer32,
|
||
sleAdvaRemFramesLostDuetoOAMErr
|
||
Integer32,
|
||
sleAdvaLocErrSymbolPeriodEvent
|
||
Integer32,
|
||
sleAdvaLocErrFrameSecsEvent
|
||
Integer32,
|
||
sleAdvaLocErrFramePeriodEvent
|
||
Integer32,
|
||
sleAdvaLocErrFrameSecsSummaryEvent
|
||
Integer32,
|
||
sleAdvaRemErrSymbolPeriodEvent
|
||
Integer32,
|
||
sleAdvaRemErrFrameSecsEvent
|
||
Integer32,
|
||
sleAdvaRemoteErrorFramePeriodEvent
|
||
Integer32,
|
||
sleAdvaRemoteErrorFrameSecsSummaryEvent
|
||
Integer32
|
||
}
|
||
|
||
sleAdvaAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMAdminState (Configuration)Whether
|
||
the OAM sublayer is enabled or disabled."
|
||
::= { sleAdvaOamEntry 1 }
|
||
|
||
|
||
sleAdvaMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
passive(0),
|
||
active(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMMode. (Configuration)Mode of the OAM client"
|
||
::= { sleAdvaOamEntry 2 }
|
||
|
||
|
||
sleAdvaRemMACAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemoteMACAddress. (Configuration)"
|
||
::= { sleAdvaOamEntry 3 }
|
||
|
||
|
||
sleAdvaRemConfig OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
unidirSupport(0),
|
||
loopbackSupport(1),
|
||
linkEvents(2),
|
||
variableRetrieval(3),
|
||
orgSpecific(4),
|
||
orgSpecificEvents(5),
|
||
orgSpecificInfoTLV(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemoteConfiguration. (Configuration)Bit-mask
|
||
corresponding to the OAM configuration field:"
|
||
::= { sleAdvaOamEntry 4 }
|
||
|
||
|
||
sleAdvaRemPduConfig OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemotePDUConfiguration. (Configuration)The maximum
|
||
PDU size supported"
|
||
::= { sleAdvaOamEntry 5 }
|
||
|
||
|
||
sleAdvaLocFlags OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
linkFault(0),
|
||
dyingGasp(1),
|
||
criticalEvent(2),
|
||
localStableDiscovering(3),
|
||
localStable(4),
|
||
remoteStableDiscovering(5),
|
||
remoteStable(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMLocalFlags. (Configuration)Bit-mask corresponding
|
||
to the OAM flag field transmitted:"
|
||
::= { sleAdvaOamEntry 6 }
|
||
|
||
|
||
sleAdvaRemFlags OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
linkFault(0),
|
||
dyingGasp(1),
|
||
criticalEvent(2),
|
||
localStableDiscovering(3),
|
||
localStable(4),
|
||
remoteStableDiscovering(5),
|
||
remoteStable(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemoteFlags. (Configuration)Bit-mask corresponding
|
||
to the OAM flag field received"
|
||
::= { sleAdvaOamEntry 7 }
|
||
|
||
|
||
sleAdvaRemState OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
reserved(0),
|
||
parserAction1(1),
|
||
parserAction2(2),
|
||
muxAction(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemoteState. (Configuration)Bit-mask corresponding
|
||
to the OAM State field received"
|
||
::= { sleAdvaOamEntry 8 }
|
||
|
||
|
||
sleAdvaRemVendorOUI OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemoteVendorOUI. (Configuration)The value of
|
||
the OUI from the remote end of the OAM link."
|
||
::= { sleAdvaOamEntry 9 }
|
||
|
||
|
||
sleAdvaRemDeviceNumber OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemoteVendorIdDeviceNumber. (Configuration)
|
||
The value of the Device Identifier from the remote end of the OAM link."
|
||
::= { sleAdvaOamEntry 10 }
|
||
|
||
|
||
sleAdvaRemVendorVersion OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMRemoteVendorIdVersion. (Configuration)
|
||
The value of the Version Identifier from the remote end of the OAM link."
|
||
::= { sleAdvaOamEntry 11 }
|
||
|
||
|
||
sleAdvaLocErrSymbolPeriodEventConfig OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMLocalErrSymPeriodConfig. (Configuration)
|
||
Configuration for the event indicating the duration of
|
||
the period and the number of symbols that must be exceeded."
|
||
::= { sleAdvaOamEntry 12 }
|
||
|
||
|
||
sleAdvaLocErrFrameEventConfig OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMLocalErrFrameConfig. (Configuration)
|
||
Configuration for the event indicating the duration and
|
||
the number of errored frames that must be exceeded."
|
||
::= { sleAdvaOamEntry 13 }
|
||
|
||
|
||
sleAdvaLocErrFramePeriodEventConfig OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMLocalErrFramePeriodConfig. (Configuration)
|
||
Configuration for the event indicating the durationin terms of
|
||
minFrameSize that can be transmitted and that number of errored
|
||
frames that must be exceeded."
|
||
::= { sleAdvaOamEntry 14 }
|
||
|
||
|
||
sleAdvaLocErrFrameSecsSummaryEventConfig OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMLocalErrFrameSecsSummaryConfig. (Configuration)
|
||
Configuration for the evert indicating duration window and number
|
||
of errored frame seconds in that duration that must be exceeded."
|
||
::= { sleAdvaOamEntry 15 }
|
||
|
||
|
||
sleAdvaPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMPDUTx. (PDU Performance)Non-resettable,
|
||
wrapping count of OAM PDUs transmitted since OAM enabled."
|
||
::= { sleAdvaOamEntry 16 }
|
||
|
||
|
||
sleAdvaPDUsRx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMPDURx. (PDU Performance)Non-resettable,
|
||
wrapping count of OAM PDUs received since OAM enabled."
|
||
::= { sleAdvaOamEntry 17 }
|
||
|
||
|
||
sleAdvaUnsupportedCodesRx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMUnsupportedCodesRx. (PDU Performance)Non-resettable,
|
||
wrapping count of OAM PDUs received that are not supported by device
|
||
since OAM enabled."
|
||
::= { sleAdvaOamEntry 18 }
|
||
|
||
|
||
sleAdvaInfoPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMInformationTx. (PDU Performance)Non-resettable,
|
||
wrapping count of OAM Info PDUs transmitted since OAM enabled."
|
||
::= { sleAdvaOamEntry 19 }
|
||
|
||
|
||
sleAdvaInfoPDUsRx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMInformationRx. (PDU Performance)Non-resettable,
|
||
wrapping count of OAM Info PDUs received since OAM enabled."
|
||
::= { sleAdvaOamEntry 20 }
|
||
|
||
|
||
sleAdvaEventNotificationPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMEventNotificationTx. (PDU Performance)Non-resettable,
|
||
wrapping count of OAM Event PDUs transmitted since OAM enabled."
|
||
::= { sleAdvaOamEntry 21 }
|
||
|
||
|
||
sleAdvaUniqueEventNotificationPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMUniqueEventNotificationTx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Event PDUs received with
|
||
a different sequence number than previously since OAM enabled."
|
||
::= { sleAdvaOamEntry 22 }
|
||
|
||
|
||
sleAdvaDupEventNotificationPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMDuplicateEventNotificationTx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Event PDUs received with the
|
||
same sequence number as previously since OAM enabled."
|
||
::= { sleAdvaOamEntry 23 }
|
||
|
||
|
||
sleAdvaLoopbackControlPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMLoopbackControlTx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Loopback Control PDUs
|
||
transmitted since OAM enabled."
|
||
::= { sleAdvaOamEntry 24 }
|
||
|
||
|
||
sleAdvaLoopbackControlPDUsRx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMLoopbackControlRx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Loopback Control PDUs
|
||
received since OAM enabled."
|
||
::= { sleAdvaOamEntry 25 }
|
||
|
||
|
||
sleAdvaVariableRequestPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMVariableRequestTx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Variable Request PDUs
|
||
transmitted since OAM enabled."
|
||
::= { sleAdvaOamEntry 26 }
|
||
|
||
|
||
sleAdvaVariableRequestPDUsRx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMVariableRequestRx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Variable Request PDUs
|
||
received since OAM enabled."
|
||
::= { sleAdvaOamEntry 27 }
|
||
|
||
|
||
sleAdvaVariableResponsePDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMVariableResponseTx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Variable Response PDUs
|
||
transmitted since OAM enabled."
|
||
::= { sleAdvaOamEntry 28 }
|
||
|
||
|
||
sleAdvaVariableResponsePDUsRx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMVariableResponseRx. (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Variable Response PDUs
|
||
received since OAM enabled"
|
||
::= { sleAdvaOamEntry 29 }
|
||
|
||
|
||
sleAdvaVendorPDUsTx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMOrganizationSpecificTx . (PDU Performance)
|
||
Non-resettable, wrapping count of OAM Vendor PDUs transmitted
|
||
since OAM enabled."
|
||
::= { sleAdvaOamEntry 30 }
|
||
|
||
|
||
sleAdvaVendorPDUsRx OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aOAMOrganizationSpecificRx. (PDU Performance)"
|
||
::= { sleAdvaOamEntry 31 }
|
||
|
||
|
||
sleAdvaRemFramesLostDuetoOAMErr OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM package - aFramesLostDueToOAMError. (PDU Performance)
|
||
Non-resettable, wrapping count of frames that would have been
|
||
transmitted but for an OAM sublayer error."
|
||
::= { sleAdvaOamEntry 32 }
|
||
|
||
|
||
sleAdvaLocErrSymbolPeriodEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently transmitted event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 33 }
|
||
|
||
|
||
sleAdvaLocErrFrameSecsEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently transmitted event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 34 }
|
||
|
||
|
||
sleAdvaLocErrFramePeriodEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently transmitted event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 35 }
|
||
|
||
|
||
sleAdvaLocErrFrameSecsSummaryEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently transmitted event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 36 }
|
||
|
||
|
||
sleAdvaRemErrSymbolPeriodEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently received event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 37 }
|
||
|
||
|
||
sleAdvaRemErrFrameSecsEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently received event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 38 }
|
||
|
||
|
||
sleAdvaRemoteErrorFramePeriodEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently received event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 39 }
|
||
|
||
|
||
sleAdvaRemoteErrorFrameSecsSummaryEvent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The most recently received event of this type. (Error)"
|
||
::= { sleAdvaOamEntry 40 }
|
||
|
||
|
||
sleAdvaOamControl OBJECT IDENTIFIER ::= { sleAdvaOam 2 }
|
||
|
||
|
||
sleAdvaOamControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER { setAdvaOamProfile(1) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 1 }
|
||
|
||
|
||
sleAdvaOamControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 2 }
|
||
|
||
|
||
sleAdvaOamControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 3 }
|
||
|
||
|
||
sleAdvaOamControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 4 }
|
||
|
||
|
||
sleAdvaOamControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 5 }
|
||
|
||
|
||
sleAdvaOamControlPortIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 6 }
|
||
|
||
|
||
sleAdvaOamControlRemInstance OBJECT-TYPE
|
||
SYNTAX INTEGER (1..2)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 7 }
|
||
|
||
|
||
sleAdvaOamControlAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 8 }
|
||
|
||
|
||
sleAdvaOamControlMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
passive(0),
|
||
active(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamControl 9 }
|
||
|
||
|
||
sleAdvaOamNotification OBJECT IDENTIFIER ::= { sleAdvaOam 3 }
|
||
|
||
|
||
setAdvaOamProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAdvaOamControlRequest, sleAdvaOamControlReqResult, sleAdvaOamControlTimeStamp, sleAdvaAdminStatus, sleAdvaMode
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAdvaOamNotification 1 }
|
||
|
||
|
||
sleAlarmLED OBJECT IDENTIFIER ::= { sleFaultMgmt 11 }
|
||
|
||
|
||
sleAlarmLEDTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAlarmLEDEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLED 1 }
|
||
|
||
|
||
sleAlarmLEDEntry OBJECT-TYPE
|
||
SYNTAX SleAlarmLEDEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleAlarmLEDType }
|
||
::= { sleAlarmLEDTable 1 }
|
||
|
||
|
||
SleAlarmLEDEntry ::=
|
||
SEQUENCE {
|
||
sleAlarmLEDType
|
||
INTEGER,
|
||
sleAlarmLEDStatus
|
||
INTEGER,
|
||
sleAlarmLEDLevel
|
||
INTEGER
|
||
}
|
||
|
||
sleAlarmLEDType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
fanFail(1),
|
||
fanRemove(2),
|
||
memoryOver(3),
|
||
moduleRemove(4),
|
||
portLinkDown(5),
|
||
portRemove(6),
|
||
portThreadOver(7),
|
||
powerFail(8),
|
||
powerRemove(9),
|
||
temperatureHigh(10),
|
||
slotRemove(11),
|
||
ponLOS(12)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The alarm that LED indicate."
|
||
::= { sleAlarmLEDEntry 1 }
|
||
|
||
|
||
sleAlarmLEDStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2),
|
||
unknown(255)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of alarm LED."
|
||
::= { sleAlarmLEDEntry 2 }
|
||
|
||
|
||
sleAlarmLEDLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
unrated(255)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Level of alarm LED."
|
||
::= { sleAlarmLEDEntry 3 }
|
||
|
||
|
||
sleAlarmLEDLevelTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleAlarmLEDLevelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLED 2 }
|
||
|
||
|
||
sleAlarmLEDLevelEntry OBJECT-TYPE
|
||
SYNTAX SleAlarmLEDLevelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleAlarmLEDLevelIndex }
|
||
::= { sleAlarmLEDLevelTable 1 }
|
||
|
||
|
||
SleAlarmLEDLevelEntry ::=
|
||
SEQUENCE {
|
||
sleAlarmLEDLevelIndex
|
||
INTEGER,
|
||
sleAlarmLEDLevelBlock
|
||
INTEGER,
|
||
sleAlarmLEDLevelOperStatus
|
||
INTEGER
|
||
}
|
||
|
||
sleAlarmLEDLevelIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
error(4),
|
||
unrated(255)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"LED level index."
|
||
::= { sleAlarmLEDLevelEntry 1 }
|
||
|
||
|
||
sleAlarmLEDLevelBlock OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unblock(1),
|
||
block(2),
|
||
unknown(255)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"LED level block."
|
||
::= { sleAlarmLEDLevelEntry 2 }
|
||
|
||
|
||
sleAlarmLEDLevelOperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
on(1),
|
||
off(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Alarm current operation status."
|
||
::= { sleAlarmLEDLevelEntry 3 }
|
||
|
||
|
||
sleAlarmLEDControl OBJECT IDENTIFIER ::= { sleAlarmLED 3 }
|
||
|
||
|
||
sleAlarmLEDControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
alarmLedOff(1),
|
||
setAlarmLedLevel(2),
|
||
clearAlarmLed(3),
|
||
alarmLedBlock(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDControl 1 }
|
||
|
||
|
||
sleAlarmLEDControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDControl 2 }
|
||
|
||
|
||
sleAlarmLEDControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDControl 3 }
|
||
|
||
|
||
sleAlarmLEDControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDControl 4 }
|
||
|
||
|
||
sleAlarmLEDControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDControl 5 }
|
||
|
||
|
||
sleAlarmLEDControlType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
fanFail(1),
|
||
fanRemove(2),
|
||
memoryOver(3),
|
||
moduleRemove(4),
|
||
portLinkDown(5),
|
||
portRemove(6),
|
||
portThreadOver(7),
|
||
powerFail(8),
|
||
powerRemove(9),
|
||
temperatureHigh(10),
|
||
slotRemove(11),
|
||
ponLOS(12)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The alarm that LED indicate."
|
||
::= { sleAlarmLEDControl 6 }
|
||
|
||
|
||
sleAlarmLEDControlLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
critical(1),
|
||
major(2),
|
||
minor(3),
|
||
all(254)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Level of alarm LED."
|
||
::= { sleAlarmLEDControl 7 }
|
||
|
||
|
||
sleAlarmLEDControlBlock OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unblock(1),
|
||
block(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"LED level block."
|
||
::= { sleAlarmLEDControl 8 }
|
||
|
||
|
||
sleAlarmLEDNotification OBJECT IDENTIFIER ::= { sleAlarmLED 4 }
|
||
|
||
|
||
sleAlarmLEDOffChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlLevel }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDNotification 1 }
|
||
|
||
|
||
sleAlarmLEDLevelChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType, sleAlarmLEDControlLevel
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDNotification 2 }
|
||
|
||
|
||
sleAlarmLEDCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDNotification 3 }
|
||
|
||
|
||
sleAlarmLEDBlockChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlLevel, sleAlarmLEDControlBlock
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleAlarmLEDNotification 4 }
|
||
|
||
|
||
sleY1731Oam OBJECT IDENTIFIER ::= { sleFaultMgmt 12 }
|
||
|
||
|
||
sleY1731Base OBJECT IDENTIFIER ::= { sleY1731Oam 1 }
|
||
|
||
|
||
sleY1731BaseGroup OBJECT IDENTIFIER ::= { sleY1731Base 1 }
|
||
|
||
|
||
sleY1731Enable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Ddisables ITU-T Y.1731 OAM function"
|
||
::= { sleY1731BaseGroup 1 }
|
||
|
||
|
||
sleY1731TrunkEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables Y.1731 OAM on a trunk port"
|
||
::= { sleY1731BaseGroup 2 }
|
||
|
||
|
||
sleY1731LtrCacheHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that cache entries will be retained"
|
||
::= { sleY1731BaseGroup 3 }
|
||
|
||
|
||
sleY1731LtrCacheSize OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of entries in the traceroute cache"
|
||
::= { sleY1731BaseGroup 4 }
|
||
|
||
|
||
sleY1731SnmpServerTraps OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
rdi(0),
|
||
loc(1),
|
||
unp(2),
|
||
unm(3),
|
||
mmg(4),
|
||
unl(5),
|
||
ais(6),
|
||
lck(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the SNMP traps"
|
||
::= { sleY1731BaseGroup 5 }
|
||
|
||
|
||
sleY1731XcheckStartDelay OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the delay before the cross-check is started"
|
||
::= { sleY1731BaseGroup 6 }
|
||
|
||
|
||
sleY1731DefaultMegLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the level to be created dynamic MHF"
|
||
::= { sleY1731BaseGroup 7 }
|
||
|
||
|
||
sleY1731DefaultMegMhfCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
default(1),
|
||
explicit(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the mode of MHF creation"
|
||
::= { sleY1731BaseGroup 8 }
|
||
|
||
|
||
sleY1731PduToCfm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables changing from Y.1731 PDU format to CFM PDU format"
|
||
::= { sleY1731BaseGroup 9 }
|
||
|
||
|
||
sleY1731DedicatedVlan OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731BaseGroup 10 }
|
||
|
||
|
||
sleY1731RmepCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
dynamic(1),
|
||
static(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"RMEP creation mode"
|
||
::= { sleY1731BaseGroup 11 }
|
||
|
||
|
||
sleY1731CCIgnoreDefect OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"CC Ignore Defect Mode"
|
||
::= { sleY1731BaseGroup 12 }
|
||
|
||
|
||
sleY1731RapsFloodingBlock OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"R-APS Flooding Block Mode"
|
||
::= { sleY1731BaseGroup 13 }
|
||
|
||
|
||
sleY1731TlvPermission OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
chassis(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates TLV Permission"
|
||
::= { sleY1731BaseGroup 14 }
|
||
|
||
|
||
sleY1731BaseControl OBJECT IDENTIFIER ::= { sleY1731Base 2 }
|
||
|
||
|
||
sleY1731BaseControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setY1731Enable(1),
|
||
setY1731TrunkEnable(2),
|
||
setY1731LtrCacheProfile(3),
|
||
setY1731SnmpProfile(4),
|
||
setY1731XcheckProfile(5),
|
||
setY1731DefaultMegProfile(6),
|
||
setY1731PduToCfm(7),
|
||
setY1731DedicatedVlan(8),
|
||
destroyMipCcdb(9),
|
||
destroyLtrCache(10),
|
||
setRmepCreation(11),
|
||
setTrunkOamstatus(12),
|
||
setY1731CCIgnoreDefect(13),
|
||
setY1731RapsFloodingBlock(14),
|
||
setY1731TlvPermission(15)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" This attribute identifies the control commands.
|
||
updateAlarmList:
|
||
the NE updates entries of alarms in the sleAlarmListTable
|
||
after having changed alarm severities of alarms
|
||
(due to change profile pointers in
|
||
managed entities or after modification of alarm severities
|
||
in profiles). This command should be applied once after having
|
||
finisled modifications of severties.
|
||
modifyAlarmSeverity:
|
||
modifies the severity of an alarm in specific profile.
|
||
createAlarmSeverityProfile:
|
||
creates a new profile with default severities.
|
||
The severities then have to be modified with command changeAlarmSeverity.
|
||
deleteAlarmSeverityProfile:
|
||
deletes a profile. Profile 1 is not allowed to be deleted.
|
||
|
||
Notifications : none "
|
||
::= { sleY1731BaseControl 1 }
|
||
|
||
|
||
sleY1731BaseControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleY1731BaseControl 2 }
|
||
|
||
|
||
sleY1731BaseControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleY1731BaseControl 3 }
|
||
|
||
|
||
sleY1731BaseControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleY1731BaseControl 4 }
|
||
|
||
|
||
sleY1731BaseControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleY1731BaseControl 5 }
|
||
|
||
|
||
sleY1731BaseControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Ddisables ITU-T Y.1731 OAM function"
|
||
::= { sleY1731BaseControl 6 }
|
||
|
||
|
||
sleY1731BaseControlTrunkEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables Y.1731 OAM on a trunk port"
|
||
::= { sleY1731BaseControl 7 }
|
||
|
||
|
||
sleY1731BaseControlLtrCacheHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that cache entries will be retained"
|
||
::= { sleY1731BaseControl 8 }
|
||
|
||
|
||
sleY1731BaseControlLtrCacheSize OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of entries in the traceroute cache"
|
||
::= { sleY1731BaseControl 9 }
|
||
|
||
|
||
sleY1731BaseControlSnmpServerTraps OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
rdi(0),
|
||
loc(1),
|
||
unp(2),
|
||
unm(3),
|
||
mmg(4),
|
||
unl(5),
|
||
ais(6),
|
||
lck(7)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the SNMP traps"
|
||
::= { sleY1731BaseControl 10 }
|
||
|
||
|
||
sleY1731BaseControlXcheckStartDelay OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the delay before the cross-check is started"
|
||
::= { sleY1731BaseControl 11 }
|
||
|
||
|
||
sleY1731BaseControlDefaultMegLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the level to be created dynamic MHF"
|
||
::= { sleY1731BaseControl 12 }
|
||
|
||
|
||
sleY1731BaseControlDefaultMegMhfCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
default(1),
|
||
explicit(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the mode of MHF creation"
|
||
::= { sleY1731BaseControl 13 }
|
||
|
||
|
||
sleY1731BaseControlPduToCfm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731BaseControl 14 }
|
||
|
||
|
||
sleY1731BaseControlDedicatedVlan OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731BaseControl 15 }
|
||
|
||
|
||
sleY1731BaseControlRmepCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
dynamic(1),
|
||
static(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"RMEP creation mode"
|
||
::= { sleY1731BaseControl 16 }
|
||
|
||
|
||
sleY1731BaseControlTrunkIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Trunk Index"
|
||
::= { sleY1731BaseControl 17 }
|
||
|
||
|
||
sleY1731BaseControlTrunkOamStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM status per each Trunk port."
|
||
::= { sleY1731BaseControl 18 }
|
||
|
||
|
||
sleY1731BaseControlTrunkMeg OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"trunk port meg name."
|
||
::= { sleY1731BaseControl 19 }
|
||
|
||
|
||
sleY1731BaseControlCCIgnoreDefect OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"CC Ignore Defect Mode"
|
||
::= { sleY1731BaseControl 20 }
|
||
|
||
|
||
sleY1731BaseControlRapsFloodingBlock OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"R-APS Flooding Block Mode"
|
||
::= { sleY1731BaseControl 21 }
|
||
|
||
|
||
sleY1731BaseControlTlvPermission OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
chassis(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates TLV Permission"
|
||
::= { sleY1731BaseControl 22 }
|
||
|
||
|
||
sleY1731BaseNotification OBJECT IDENTIFIER ::= { sleY1731Base 3 }
|
||
|
||
|
||
sleY1731EnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731Enable"
|
||
::= { sleY1731BaseNotification 1 }
|
||
|
||
|
||
sleY1731TrunkEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTrunkEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731TrunkEnable"
|
||
::= { sleY1731BaseNotification 2 }
|
||
|
||
|
||
sleY1731LtrCacheProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlLtrCacheHoldTime, sleY1731BaseControlLtrCacheSize
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731LtrCacheProfile"
|
||
::= { sleY1731BaseNotification 3 }
|
||
|
||
|
||
sleY1731SnmpProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlSnmpServerTraps }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731SnmpProfile"
|
||
::= { sleY1731BaseNotification 4 }
|
||
|
||
|
||
sleY1731XcheckProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlXcheckStartDelay }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731XcheckProfile"
|
||
::= { sleY1731BaseNotification 5 }
|
||
|
||
|
||
sleY1731DefaultMegProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlDefaultMegLevel, sleY1731BaseControlDefaultMegMhfCreation
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731DefaultMegProfile"
|
||
::= { sleY1731BaseNotification 6 }
|
||
|
||
|
||
sleY1731PduToCfmChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlPduToCfm }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731BaseNotification 7 }
|
||
|
||
|
||
sleY1731DedicatedVlanChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlDedicatedVlan }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731BaseNotification 8 }
|
||
|
||
|
||
sleY1731MipCcdbDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyMipCcdb"
|
||
::= { sleY1731BaseNotification 9 }
|
||
|
||
|
||
sleY1731LtrCacheDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyLtrCache"
|
||
::= { sleY1731BaseNotification 10 }
|
||
|
||
|
||
sleY1731RmepCreationChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlRmepCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"sleY1731BaseControlRmepCreation"
|
||
::= { sleY1731BaseNotification 11 }
|
||
|
||
|
||
sleY1731TrunkOamStatusChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTrunkIndex, sleY1731BaseControlTrunkOamStatus,
|
||
sleY1731BaseControlTrunkMeg }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"sleY1731BaseControlTrunkIndex
|
||
sleY1731BaseControlTrunkOamStatus"
|
||
::= { sleY1731BaseNotification 12 }
|
||
|
||
|
||
sleY1731CCIgnoreDefectChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlCCIgnoreDefect }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"sleY1731BaseControlCCIgnoreDefect"
|
||
::= { sleY1731BaseNotification 13 }
|
||
|
||
|
||
sleY1731RapsFloodinBlockChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlRapsFloodingBlock }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"sleY1731BaseControlCCIgnoreDefect"
|
||
::= { sleY1731BaseNotification 14 }
|
||
|
||
|
||
sleY1731TlvPermissionChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTlvPermission }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731TlvPermission"
|
||
::= { sleY1731BaseNotification 15 }
|
||
|
||
|
||
sleY1731TrunkTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731TrunkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731Base 4 }
|
||
|
||
|
||
sleY1731TrunkEntry OBJECT-TYPE
|
||
SYNTAX SleY1731TrunkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731TrunkIndex }
|
||
::= { sleY1731TrunkTable 1 }
|
||
|
||
|
||
SleY1731TrunkEntry ::=
|
||
SEQUENCE {
|
||
sleY1731TrunkIndex
|
||
INTEGER,
|
||
sleY1731TrunkOamStatus
|
||
INTEGER,
|
||
sleY1731TrunkMeg
|
||
OCTET STRING
|
||
}
|
||
|
||
sleY1731TrunkIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"trunk port index."
|
||
::= { sleY1731TrunkEntry 1 }
|
||
|
||
|
||
sleY1731TrunkOamStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OAM status per each Trunk port."
|
||
::= { sleY1731TrunkEntry 2 }
|
||
|
||
|
||
sleY1731TrunkMeg OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"trunk port meg name."
|
||
::= { sleY1731TrunkEntry 3 }
|
||
|
||
|
||
sleY1731Meg OBJECT IDENTIFIER ::= { sleY1731Oam 2 }
|
||
|
||
|
||
sleY1731MegTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731MegEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731Meg 1 }
|
||
|
||
|
||
sleY1731MegEntry OBJECT-TYPE
|
||
SYNTAX SleY1731MegEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex }
|
||
::= { sleY1731MegTable 1 }
|
||
|
||
|
||
SleY1731MegEntry ::=
|
||
SEQUENCE {
|
||
sleY1731MegIndex
|
||
Integer32,
|
||
sleY1731MegName
|
||
OCTET STRING,
|
||
sleY1731MegLevel
|
||
Integer32,
|
||
sleY1731MegVid
|
||
Integer32,
|
||
sleY1731MegMepEnable
|
||
INTEGER,
|
||
sleY1731MegCcEnable
|
||
INTEGER,
|
||
sleY1731MegCcInterval
|
||
Integer32,
|
||
sleY1731MegCcPriority
|
||
Integer32,
|
||
sleY1731MegCcLossThreshold
|
||
Integer32,
|
||
sleY1731MegCcHoldTime
|
||
Integer32,
|
||
sleY1731MegFaultPriority
|
||
Integer32,
|
||
sleY1731MegFaultKeepTime
|
||
Integer32,
|
||
sleY1731MegFaultClearTime
|
||
Integer32,
|
||
sleY1731MegXcheckEnable
|
||
INTEGER,
|
||
sleY1731MegAisEnable
|
||
INTEGER,
|
||
sleY1731MegAisTransmitEnable
|
||
INTEGER,
|
||
sleY1731MegAisInterval
|
||
INTEGER,
|
||
sleY1731MegAisLevel
|
||
Integer32,
|
||
sleY1731MegAisPriority
|
||
Integer32,
|
||
sleY1731MegLckEnable
|
||
INTEGER,
|
||
sleY1731MegLckTransmitEnable
|
||
INTEGER,
|
||
sleY1731MegLckInterval
|
||
INTEGER,
|
||
sleY1731MegLckLevel
|
||
Integer32,
|
||
sleY1731MegLckPriority
|
||
Integer32,
|
||
sleY1731MegOutOfService
|
||
INTEGER,
|
||
sleY1731MegRapsEnable
|
||
INTEGER,
|
||
sleY1731MegRapsRplOwner
|
||
INTEGER,
|
||
sleY1731MegRapsEastPort
|
||
Integer32,
|
||
sleY1731MegRapsWestPort
|
||
Integer32,
|
||
sleY1731MegRapsRplPort
|
||
INTEGER,
|
||
sleY1731MegRapsHoldOffTime
|
||
Integer32,
|
||
sleY1731MegRapsGuardTime
|
||
Integer32,
|
||
sleY1731MegRapsWaitToRestore
|
||
Integer32,
|
||
sleY1731MegRapsState
|
||
INTEGER,
|
||
sleY1731MegRapsEastPortStatus
|
||
INTEGER,
|
||
sleY1731MegRapsWestPortStatus
|
||
INTEGER,
|
||
sleY1731MegRapsNonRevertive
|
||
INTEGER,
|
||
sleY1731MegRapsForcedSwitchEast
|
||
INTEGER,
|
||
sleY1731MegRapsForcedSwitchWest
|
||
INTEGER,
|
||
sleY1731MegMd
|
||
OCTET STRING
|
||
}
|
||
|
||
sleY1731MegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index"
|
||
::= { sleY1731MegEntry 1 }
|
||
|
||
|
||
sleY1731MegName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MEG's name: ICC (6 bytes) + UMC (6 bytes)"
|
||
::= { sleY1731MegEntry 2 }
|
||
|
||
|
||
sleY1731MegLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's level"
|
||
::= { sleY1731MegEntry 3 }
|
||
|
||
|
||
sleY1731MegVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's VID"
|
||
::= { sleY1731MegEntry 4 }
|
||
|
||
|
||
sleY1731MegMepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables Y.1731 OAM for MEPs"
|
||
::= { sleY1731MegEntry 5 }
|
||
|
||
|
||
sleY1731MegCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables MEPs to send Continuity Check messages"
|
||
::= { sleY1731MegEntry 6 }
|
||
|
||
|
||
sleY1731MegCcInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1 | 2..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between CCM transmissions"
|
||
::= { sleY1731MegEntry 7 }
|
||
|
||
|
||
sleY1731MegCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM or LTM Message Priority"
|
||
::= { sleY1731MegEntry 8 }
|
||
|
||
|
||
sleY1731MegCcLossThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (2..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
|
||
::= { sleY1731MegEntry 9 }
|
||
|
||
|
||
sleY1731MegCcHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that data of a missing MEP is kept"
|
||
::= { sleY1731MegEntry 10 }
|
||
|
||
|
||
sleY1731MegFaultPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the lowest priority for fault alarm"
|
||
::= { sleY1731MegEntry 11 }
|
||
|
||
|
||
sleY1731MegFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the keep time for the fault alarm"
|
||
::= { sleY1731MegEntry 12 }
|
||
|
||
|
||
sleY1731MegFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the clear time for the fault alarm"
|
||
::= { sleY1731MegEntry 13 }
|
||
|
||
|
||
sleY1731MegXcheckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables Y.1731 cross-check for a specific MEG"
|
||
::= { sleY1731MegEntry 14 }
|
||
|
||
|
||
sleY1731MegAisEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-AIS function"
|
||
::= { sleY1731MegEntry 15 }
|
||
|
||
|
||
sleY1731MegAisTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-AIS frame transmission on a MEP"
|
||
::= { sleY1731MegEntry 16 }
|
||
|
||
|
||
sleY1731MegAisInterval OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
oneSecond(4),
|
||
oneMinute(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between AIS transmissions"
|
||
::= { sleY1731MegEntry 17 }
|
||
|
||
|
||
sleY1731MegAisLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (1..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the client MEG's level"
|
||
::= { sleY1731MegEntry 18 }
|
||
|
||
|
||
sleY1731MegAisPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the AIS Message Priority"
|
||
::= { sleY1731MegEntry 19 }
|
||
|
||
|
||
sleY1731MegLckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-LCK function"
|
||
::= { sleY1731MegEntry 20 }
|
||
|
||
|
||
sleY1731MegLckTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-LCK frame transmission on a MEP"
|
||
::= { sleY1731MegEntry 21 }
|
||
|
||
|
||
sleY1731MegLckInterval OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
oneSecond(4),
|
||
oneMinute(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between LCK transmissions"
|
||
::= { sleY1731MegEntry 22 }
|
||
|
||
|
||
sleY1731MegLckLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (1..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the client MEG's level"
|
||
::= { sleY1731MegEntry 23 }
|
||
|
||
|
||
sleY1731MegLckPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the LCK Message Priority"
|
||
::= { sleY1731MegEntry 24 }
|
||
|
||
|
||
sleY1731MegOutOfService OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the out-of-service mode"
|
||
::= { sleY1731MegEntry 25 }
|
||
|
||
|
||
sleY1731MegRapsEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables R-APS node"
|
||
::= { sleY1731MegEntry 26 }
|
||
|
||
|
||
sleY1731MegRapsRplOwner OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the owner of the ring protection link"
|
||
::= { sleY1731MegEntry 27 }
|
||
|
||
|
||
sleY1731MegRapsEastPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the east port of R-APS node"
|
||
::= { sleY1731MegEntry 28 }
|
||
|
||
|
||
sleY1731MegRapsWestPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the west port of R-APS node"
|
||
::= { sleY1731MegEntry 29 }
|
||
|
||
|
||
sleY1731MegRapsRplPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(-1),
|
||
east(0),
|
||
west(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the RPL port of R-APS node"
|
||
::= { sleY1731MegEntry 30 }
|
||
|
||
|
||
sleY1731MegRapsHoldOffTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..10000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the hold-off time for verifying local SF"
|
||
::= { sleY1731MegEntry 31 }
|
||
|
||
|
||
sleY1731MegRapsGuardTime OBJECT-TYPE
|
||
SYNTAX Integer32 (10..2000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the guard time for verifying local clear SF"
|
||
::= { sleY1731MegEntry 32 }
|
||
|
||
|
||
sleY1731MegRapsWaitToRestore OBJECT-TYPE
|
||
SYNTAX Integer32 (5..720)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time for verifying remote SF"
|
||
::= { sleY1731MegEntry 33 }
|
||
|
||
|
||
sleY1731MegRapsState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
idle(1),
|
||
protection(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate the state of r-aps state machine"
|
||
::= { sleY1731MegEntry 34 }
|
||
|
||
|
||
sleY1731MegRapsEastPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
disabled(1),
|
||
forwarding(2),
|
||
blocking(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The port status of east port."
|
||
::= { sleY1731MegEntry 35 }
|
||
|
||
|
||
sleY1731MegRapsWestPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
disabled(1),
|
||
forwarding(2),
|
||
blocking(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The port status of west port."
|
||
::= { sleY1731MegEntry 36 }
|
||
|
||
|
||
sleY1731MegRapsNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"NonRevertive"
|
||
::= { sleY1731MegEntry 37 }
|
||
|
||
|
||
sleY1731MegRapsForcedSwitchEast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ForcedSwitchEast"
|
||
::= { sleY1731MegEntry 38 }
|
||
|
||
|
||
sleY1731MegRapsForcedSwitchWest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ForcedSwitchWest"
|
||
::= { sleY1731MegEntry 39 }
|
||
|
||
|
||
sleY1731MegMd OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MD name of MEG."
|
||
::= { sleY1731MegEntry 40 }
|
||
|
||
|
||
sleY1731MegControl OBJECT IDENTIFIER ::= { sleY1731Meg 2 }
|
||
|
||
|
||
sleY1731MegControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731Meg(1),
|
||
deleteY1731Meg(2),
|
||
setY1731MegMepEnable(3),
|
||
setY1731MegCcEnable(4),
|
||
setY1731MegCcProfile(5),
|
||
setY1731MegFaultProfile(6),
|
||
setY1731MegXcheckEnable(7),
|
||
setY1731MegAisEnable(8),
|
||
setY1731MegAisTransmitEnable(9),
|
||
setY1731MegAisProfile(10),
|
||
setY1731MegLckEnable(11),
|
||
setY1731MegLckTransmitEnable(12),
|
||
setY1731MegLckProfile(13),
|
||
setY1731MegOutOfService(14),
|
||
setY1731MegRapsEnable(15),
|
||
setY1731MegRapsRingports(16),
|
||
setY1731MegRapsRplPort(17),
|
||
setY1731MegRapsRplOwner(18),
|
||
setY1731MegRapsRplTimer(19),
|
||
destroyY1731MegRemoteMep(20),
|
||
destroyY1731MegError(21),
|
||
setY1731MegRapsNonRevertive(22),
|
||
setY1731MegRapsForcedSwitchEast(23),
|
||
setY1731MegRapsForcedSwitchWest(24),
|
||
addY1731MegMd(25),
|
||
delY1731MegMd(26)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegControl 1 }
|
||
|
||
|
||
sleY1731MegControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegControl 2 }
|
||
|
||
|
||
sleY1731MegControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegControl 3 }
|
||
|
||
|
||
sleY1731MegControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegControl 4 }
|
||
|
||
|
||
sleY1731MegControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegControl 5 }
|
||
|
||
|
||
sleY1731MegControlIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index"
|
||
::= { sleY1731MegControl 6 }
|
||
|
||
|
||
sleY1731MegControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MEG's name: ICC (6 bytes) + UMC (6 bytes)"
|
||
::= { sleY1731MegControl 7 }
|
||
|
||
|
||
sleY1731MegControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's level"
|
||
::= { sleY1731MegControl 8 }
|
||
|
||
|
||
sleY1731MegControlVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's VID"
|
||
::= { sleY1731MegControl 9 }
|
||
|
||
|
||
sleY1731MegControlMepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables Y.1731 OAM for MEPs"
|
||
::= { sleY1731MegControl 10 }
|
||
|
||
|
||
sleY1731MegControlCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables MEPs to send Continuity Check messages"
|
||
::= { sleY1731MegControl 11 }
|
||
|
||
|
||
sleY1731MegControlCcInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1 | 2..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between CCM transmissions"
|
||
::= { sleY1731MegControl 12 }
|
||
|
||
|
||
sleY1731MegControlCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM or LTM Message Priority"
|
||
::= { sleY1731MegControl 13 }
|
||
|
||
|
||
sleY1731MegControlCcLossThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (2..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
|
||
::= { sleY1731MegControl 14 }
|
||
|
||
|
||
sleY1731MegControlCcHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that data of a missing MEP is kept"
|
||
::= { sleY1731MegControl 15 }
|
||
|
||
|
||
sleY1731MegControlFaultPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the lowest priority for fault alarm"
|
||
::= { sleY1731MegControl 16 }
|
||
|
||
|
||
sleY1731MegControlFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the keep time for the fault alarm"
|
||
::= { sleY1731MegControl 17 }
|
||
|
||
|
||
sleY1731MegControlFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the clear time for the fault alarm"
|
||
::= { sleY1731MegControl 18 }
|
||
|
||
|
||
sleY1731MegControlXcheckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables Y.1731 cross-check for a specific MEG"
|
||
::= { sleY1731MegControl 19 }
|
||
|
||
|
||
sleY1731MegControlAisEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-AIS function"
|
||
::= { sleY1731MegControl 20 }
|
||
|
||
|
||
sleY1731MegControlAisTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-AIS frame transmission on a MEP"
|
||
::= { sleY1731MegControl 21 }
|
||
|
||
|
||
sleY1731MegControlAisInterval OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
oneSecond(4),
|
||
oneMinute(6)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between AIS transmissions"
|
||
::= { sleY1731MegControl 22 }
|
||
|
||
|
||
sleY1731MegControlAisLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (1..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the client MEG's level"
|
||
::= { sleY1731MegControl 23 }
|
||
|
||
|
||
sleY1731MegControlAisPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the AIS Message Priority"
|
||
::= { sleY1731MegControl 24 }
|
||
|
||
|
||
sleY1731MegControlLckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-LCK function"
|
||
::= { sleY1731MegControl 25 }
|
||
|
||
|
||
sleY1731MegControlLckTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables ETH-LCK frame transmission on a MEP"
|
||
::= { sleY1731MegControl 26 }
|
||
|
||
|
||
sleY1731MegControlLckInterval OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
oneSecond(4),
|
||
oneMinute(6)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between LCK transmissions"
|
||
::= { sleY1731MegControl 27 }
|
||
|
||
|
||
sleY1731MegControlLckLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (1..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the client MEG's level"
|
||
::= { sleY1731MegControl 28 }
|
||
|
||
|
||
sleY1731MegControlLckPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the LCK Message Priority"
|
||
::= { sleY1731MegControl 29 }
|
||
|
||
|
||
sleY1731MegControlOutOfService OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the out-of-service mode"
|
||
::= { sleY1731MegControl 30 }
|
||
|
||
|
||
sleY1731MegControlRapsEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables R-APS node"
|
||
::= { sleY1731MegControl 31 }
|
||
|
||
|
||
sleY1731MegControlRapsRplOwner OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the owner of the ring protection link"
|
||
::= { sleY1731MegControl 32 }
|
||
|
||
|
||
sleY1731MegControlRapsEastPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the east port of R-APS node
|
||
Set zero to delete east port"
|
||
::= { sleY1731MegControl 33 }
|
||
|
||
|
||
sleY1731MegControlRapsWestPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the west port of R-APS node
|
||
Set zero to delete west port"
|
||
::= { sleY1731MegControl 34 }
|
||
|
||
|
||
sleY1731MegControlRapsRplPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(-1),
|
||
east(0),
|
||
west(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the RPL port of R-APS node"
|
||
::= { sleY1731MegControl 35 }
|
||
|
||
|
||
sleY1731MegControlRapsHoldOffTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the hold-off time for verifying local SF
|
||
The hold-off time's step must be 100
|
||
"
|
||
::= { sleY1731MegControl 36 }
|
||
|
||
|
||
sleY1731MegControlRapsGuardTime OBJECT-TYPE
|
||
SYNTAX Integer32 (10..2000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the guard time for verifying local clear SF
|
||
The guard time's step must be 10
|
||
"
|
||
::= { sleY1731MegControl 37 }
|
||
|
||
|
||
sleY1731MegControlRapsWaitToRestore OBJECT-TYPE
|
||
SYNTAX Integer32 (5..720)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time for verifying remote SF
|
||
"
|
||
::= { sleY1731MegControl 38 }
|
||
|
||
|
||
sleY1731MegControlRapsNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"NonRevertive"
|
||
::= { sleY1731MegControl 39 }
|
||
|
||
|
||
sleY1731MegControlRapsForcedSwitchEast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ForcedSwitchEast"
|
||
::= { sleY1731MegControl 40 }
|
||
|
||
|
||
sleY1731MegControlRapsForcedSwitchWest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ForcedSwitchWest"
|
||
::= { sleY1731MegControl 41 }
|
||
|
||
|
||
sleY1731MegControlMd OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MD name of MEG."
|
||
::= { sleY1731MegControl 42 }
|
||
|
||
|
||
sleY1731MegNotification OBJECT IDENTIFIER ::= { sleY1731Meg 3 }
|
||
|
||
|
||
sleY1731MegCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlLevel,
|
||
sleY1731MegControlVid }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731Meg"
|
||
::= { sleY1731MegNotification 1 }
|
||
|
||
|
||
sleY1731MegDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731Meg"
|
||
::= { sleY1731MegNotification 2 }
|
||
|
||
|
||
sleY1731MegMepEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlMepEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731MepEnable"
|
||
::= { sleY1731MegNotification 3 }
|
||
|
||
|
||
sleY1731MegCcEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlCcEnable
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731CcEnable"
|
||
::= { sleY1731MegNotification 4 }
|
||
|
||
|
||
sleY1731MegCcProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlCcInterval, sleY1731MegControlCcPriority, sleY1731MegControlCcLossThreshold, sleY1731MegControlCcHoldTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731CcProfile"
|
||
::= { sleY1731MegNotification 5 }
|
||
|
||
|
||
sleY1731MegFaultProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlFaultPriority, sleY1731MegControlFaultKeepTime, sleY1731MegControlFaultClearTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731FaultProfile"
|
||
::= { sleY1731MegNotification 6 }
|
||
|
||
|
||
sleY1731MegXcheckEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlXcheckEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731XcheckEnable"
|
||
::= { sleY1731MegNotification 7 }
|
||
|
||
|
||
sleY1731MegAisEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlAisEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731AisEnable"
|
||
::= { sleY1731MegNotification 8 }
|
||
|
||
|
||
sleY1731MegAisTransmitEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlAisTransmitEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731AisTransmitEnable"
|
||
::= { sleY1731MegNotification 9 }
|
||
|
||
|
||
sleY1731MegAisProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlAisInterval, sleY1731MegControlAisLevel, sleY1731MegControlAisPriority }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731AisProfile"
|
||
::= { sleY1731MegNotification 10 }
|
||
|
||
|
||
sleY1731MegLckEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlLckEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731LckEnable"
|
||
::= { sleY1731MegNotification 11 }
|
||
|
||
|
||
sleY1731MegLckTransmitEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlLckTransmitEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731LckTransmitEnable"
|
||
::= { sleY1731MegNotification 12 }
|
||
|
||
|
||
sleY1731MegLckProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlLckInterval, sleY1731MegControlLckLevel, sleY1731MegControlLckPriority }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731LckProfile"
|
||
::= { sleY1731MegNotification 13 }
|
||
|
||
|
||
sleY1731MegOutOfServiceChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlOutOfService }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731OutOfService"
|
||
::= { sleY1731MegNotification 14 }
|
||
|
||
|
||
sleY1731MegRapsEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlRapsEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731RapsEnable"
|
||
::= { sleY1731MegNotification 15 }
|
||
|
||
|
||
sleY1731MegRapsRingportsChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlRapsEastPort, sleY1731MegControlRapsWestPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731RapsProfile"
|
||
::= { sleY1731MegNotification 16 }
|
||
|
||
|
||
sleY1731MegRapsRplPortChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlRapsRplPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegNotification 17 }
|
||
|
||
|
||
sleY1731MegRapsRplOwnerChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlRapsRplOwner }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegNotification 18 }
|
||
|
||
|
||
sleY1731MegRapsTimerChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
|
||
sleY1731MegControlRapsHoldOffTime, sleY1731MegControlRapsGuardTime, sleY1731MegControlRapsWaitToRestore }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MegNotification 19 }
|
||
|
||
|
||
sleY1731MegRemoteMepDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyRemoteMep"
|
||
::= { sleY1731MegNotification 20 }
|
||
|
||
|
||
sleY1731MegErrorDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyError"
|
||
::= { sleY1731MegNotification 21 }
|
||
|
||
|
||
sleY1731MegRapsNonRevertiveChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsNonRevertive
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"sleY1731MegRapsNonRevertiveChanged"
|
||
::= { sleY1731MegNotification 22 }
|
||
|
||
|
||
sleY1731MegRapsForcedSwitchEastChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsForcedSwitchEast
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"sleY1731MegRapsForcedSwitchEastChanged"
|
||
::= { sleY1731MegNotification 23 }
|
||
|
||
|
||
sleY1731MegRapsForcedSwitchWestChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsForcedSwitchWest
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"sleY1731MegRapsForcedSwitchWestChanged"
|
||
::= { sleY1731MegNotification 24 }
|
||
|
||
|
||
sleY1731MegMdAdded NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlMd
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731Meg"
|
||
::= { sleY1731MegNotification 25 }
|
||
|
||
|
||
sleY1731MegMdDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlMd
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731Meg"
|
||
::= { sleY1731MegNotification 26 }
|
||
|
||
|
||
sleY1731Mep OBJECT IDENTIFIER ::= { sleY1731Oam 3 }
|
||
|
||
|
||
sleY1731MepTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731MepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731Mep 1 }
|
||
|
||
|
||
sleY1731MepEntry OBJECT-TYPE
|
||
SYNTAX SleY1731MepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier }
|
||
::= { sleY1731MepTable 1 }
|
||
|
||
|
||
SleY1731MepEntry ::=
|
||
SEQUENCE {
|
||
sleY1731MepIdentifier
|
||
Integer32,
|
||
sleY1731MepIfIndex
|
||
Integer32,
|
||
sleY1731MepDirection
|
||
INTEGER,
|
||
sleY1731MepEnable
|
||
INTEGER,
|
||
sleY1731MepFngState
|
||
INTEGER,
|
||
sleY1731MepCcEnable
|
||
INTEGER,
|
||
sleY1731MepMacAddress
|
||
OCTET STRING,
|
||
sleY1731MepFaultPriority
|
||
INTEGER,
|
||
sleY1731MepFaultKeepTime
|
||
Integer32,
|
||
sleY1731MepFaultClearTime
|
||
Integer32,
|
||
sleY1731MepHighestPrDefect
|
||
INTEGER,
|
||
sleY1731MepAisEnable
|
||
INTEGER,
|
||
sleY1731MepAisTransmitEnable
|
||
INTEGER,
|
||
sleY1731MepLckEnable
|
||
INTEGER,
|
||
sleY1731MepLckTransmitEnable
|
||
INTEGER,
|
||
sleY1731MepOutOfService
|
||
INTEGER,
|
||
sleY1731MepDlmEnabledRmep
|
||
Integer32,
|
||
sleY1731MepDefects
|
||
BITS,
|
||
sleY1731MepCcmSequenceErrors
|
||
Counter32,
|
||
sleY1731MepCciSentCcms
|
||
Counter32,
|
||
sleY1731MepNextLbmTransId
|
||
Integer32,
|
||
sleY1731MepLbSuccessRate
|
||
Integer32,
|
||
sleY1731MepLbRoundtripMin
|
||
Counter32,
|
||
sleY1731MepLbRoundtripMax
|
||
Counter32,
|
||
sleY1731MepLbRoundtripAvg
|
||
Counter32,
|
||
sleY1731MepLbrIn
|
||
Counter32,
|
||
sleY1731MepLbrInOutOfOrder
|
||
Counter32,
|
||
sleY1731MepTstLbrInBitError
|
||
Counter32,
|
||
sleY1731MepTstLbrInCrcError
|
||
Counter32,
|
||
sleY1731MepLtmNextSeqNumber
|
||
Integer32,
|
||
sleY1731MepUnexpLtrIn
|
||
Counter32,
|
||
sleY1731MepLbrOut
|
||
Counter32,
|
||
sleY1731MepTmLbmCount
|
||
Integer32,
|
||
sleY1731MepTmLbrCount
|
||
Integer32,
|
||
sleY1731MepTmLbrFirstLostId
|
||
Integer32,
|
||
sleY1731MepTmLbrMaxRate
|
||
Integer32,
|
||
sleY1731MepTmTstCount
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossNearMin
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossNearMax
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossNearSum
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossFarMin
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossFarMax
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossFarSum
|
||
Integer32,
|
||
sleY1731MepPmEnable
|
||
INTEGER,
|
||
sleY1731MepCcmFrameLossNearRatio
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossNearAvgRatio
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossFarRatio
|
||
Integer32,
|
||
sleY1731MepCcmFrameLossFarAvgRatio
|
||
Integer32,
|
||
sleY1731MepRllcf
|
||
INTEGER,
|
||
sleY1731MepRllcfHoldOff
|
||
Integer32,
|
||
sleY1731MepRllcfGuardTime
|
||
Integer32
|
||
}
|
||
|
||
sleY1731MepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MEP Id"
|
||
::= { sleY1731MepEntry 1 }
|
||
|
||
|
||
sleY1731MepIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Brige Port Index whitch the MEP is attached"
|
||
::= { sleY1731MepEntry 2 }
|
||
|
||
|
||
sleY1731MepDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
down(0),
|
||
up(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The direction in which the MEP faces on the Bridge port"
|
||
::= { sleY1731MepEntry 3 }
|
||
|
||
|
||
sleY1731MepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Administrative state of the MEP"
|
||
::= { sleY1731MepEntry 4 }
|
||
|
||
|
||
sleY1731MepFngState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
reset(1),
|
||
defect(2),
|
||
reportDefect(3),
|
||
defectReported(4),
|
||
defectCearing(5),
|
||
defectCleared(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current state of the MEP Fault Notification Generator State Machine"
|
||
::= { sleY1731MepEntry 5 }
|
||
|
||
|
||
sleY1731MepCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP will generate CCM messages"
|
||
::= { sleY1731MepEntry 6 }
|
||
|
||
|
||
sleY1731MepMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MAC address of the MEP"
|
||
::= { sleY1731MepEntry 7 }
|
||
|
||
|
||
sleY1731MepFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdi(1),
|
||
loc(2),
|
||
unp(3),
|
||
unm(4),
|
||
mmg(5),
|
||
unl(6),
|
||
ais(7),
|
||
lck(8)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
|
||
::= { sleY1731MepEntry 8 }
|
||
|
||
|
||
sleY1731MepFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be present before a Fault Alarm is issued"
|
||
::= { sleY1731MepEntry 9 }
|
||
|
||
|
||
sleY1731MepFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be absent before resetting a Fault Alarm"
|
||
::= { sleY1731MepEntry 10 }
|
||
|
||
|
||
sleY1731MepHighestPrDefect OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdi(1),
|
||
loc(2),
|
||
unp(3),
|
||
unm(4),
|
||
mmg(5),
|
||
unl(6),
|
||
ais(7),
|
||
lck(8)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine was last in the FNG_RESET state"
|
||
::= { sleY1731MepEntry 11 }
|
||
|
||
|
||
sleY1731MepAisEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the AIS function for the MEP is enabled"
|
||
::= { sleY1731MepEntry 12 }
|
||
|
||
|
||
sleY1731MepAisTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP can generate AIS messages"
|
||
::= { sleY1731MepEntry 13 }
|
||
|
||
|
||
sleY1731MepLckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the LCK function for the MEP is enabled"
|
||
::= { sleY1731MepEntry 14 }
|
||
|
||
|
||
sleY1731MepLckTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP can generate LCK messages"
|
||
::= { sleY1731MepEntry 15 }
|
||
|
||
|
||
sleY1731MepOutOfService OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP is in out-of-service."
|
||
::= { sleY1731MepEntry 16 }
|
||
|
||
|
||
sleY1731MepDlmEnabledRmep OBJECT-TYPE
|
||
SYNTAX Integer32 (0..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RMEP identifier enabled DLM functin
|
||
If set to zero, disabled DLM function.
|
||
"
|
||
::= { sleY1731MepEntry 17 }
|
||
|
||
|
||
sleY1731MepDefects OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
rdi(0),
|
||
loc(1),
|
||
unp(2),
|
||
unm(3),
|
||
mmg(4),
|
||
unl(5),
|
||
ais(6),
|
||
lck(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A vector of Boolean defect conditions"
|
||
::= { sleY1731MepEntry 18 }
|
||
|
||
|
||
sleY1731MepCcmSequenceErrors OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of out-of-sequence CCMs received from all remote MEPs"
|
||
::= { sleY1731MepEntry 19 }
|
||
|
||
|
||
sleY1731MepCciSentCcms OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total number of Continuity Check messages transmitted"
|
||
::= { sleY1731MepEntry 20 }
|
||
|
||
|
||
sleY1731MepNextLbmTransId OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Next sequence number/transaction identifier to be sent in a Loopback message"
|
||
::= { sleY1731MepEntry 21 }
|
||
|
||
|
||
sleY1731MepLbSuccessRate OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Loopback Success rate"
|
||
::= { sleY1731MepEntry 22 }
|
||
|
||
|
||
sleY1731MepLbRoundtripMin OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The minimum round trip time of Loopback message"
|
||
::= { sleY1731MepEntry 23 }
|
||
|
||
|
||
sleY1731MepLbRoundtripMax OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum round trip time of Loopback message"
|
||
::= { sleY1731MepEntry 24 }
|
||
|
||
|
||
sleY1731MepLbRoundtripAvg OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The average round trip time of Loopback message"
|
||
::= { sleY1731MepEntry 25 }
|
||
|
||
|
||
sleY1731MepLbrIn OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total number of valid, in-order Loopback Replies received"
|
||
::= { sleY1731MepEntry 26 }
|
||
|
||
|
||
sleY1731MepLbrInOutOfOrder OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of valid, out-of-order Loopback Replies received"
|
||
::= { sleY1731MepEntry 27 }
|
||
|
||
|
||
sleY1731MepTstLbrInBitError OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of invalid, bit-error Loopback Replies received for diagnostic test"
|
||
::= { sleY1731MepEntry 28 }
|
||
|
||
|
||
sleY1731MepTstLbrInCrcError OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of invalid, crc-error Loopback Replies received for diagnostic test"
|
||
::= { sleY1731MepEntry 29 }
|
||
|
||
|
||
sleY1731MepLtmNextSeqNumber OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Next transaction identifier/sequence number to be sent in a Linktrace message."
|
||
::= { sleY1731MepEntry 30 }
|
||
|
||
|
||
sleY1731MepUnexpLtrIn OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of unexpected LTRs received"
|
||
::= { sleY1731MepEntry 31 }
|
||
|
||
|
||
sleY1731MepLbrOut OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total number of Loopback Replies transmitted"
|
||
::= { sleY1731MepEntry 32 }
|
||
|
||
|
||
sleY1731MepTmLbmCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the count of LBM frame for the throughput-measurement"
|
||
::= { sleY1731MepEntry 33 }
|
||
|
||
|
||
sleY1731MepTmLbrCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the count of LBM frame for the throughput-measurement"
|
||
::= { sleY1731MepEntry 34 }
|
||
|
||
|
||
sleY1731MepTmLbrFirstLostId OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the transaction identifier of first lost LBR frame for the throughput-measurement"
|
||
::= { sleY1731MepEntry 35 }
|
||
|
||
|
||
sleY1731MepTmLbrMaxRate OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maximum transmission rate"
|
||
::= { sleY1731MepEntry 36 }
|
||
|
||
|
||
sleY1731MepTmTstCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the count of TST message for the throughput-measurement"
|
||
::= { sleY1731MepEntry 37 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossNearMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum of dual-ended near-end frame loss"
|
||
::= { sleY1731MepEntry 38 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossNearMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maximum of dual-ended near-end frame loss"
|
||
::= { sleY1731MepEntry 39 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossNearSum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the sum of dual-ended near-end frame loss"
|
||
::= { sleY1731MepEntry 40 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossFarMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum of dual-ended far-end frame loss"
|
||
::= { sleY1731MepEntry 41 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossFarMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maximum of dual-ended far-end frame loss"
|
||
::= { sleY1731MepEntry 42 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossFarSum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the sum of dual-ended far-end frame loss"
|
||
::= { sleY1731MepEntry 43 }
|
||
|
||
|
||
sleY1731MepPmEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the PM(performance monitoring) of the MEP is enabled"
|
||
::= { sleY1731MepEntry 44 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossNearRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the ratio of dual-ended near-end frame loss"
|
||
::= { sleY1731MepEntry 45 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossNearAvgRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the average ratio of dual-ended near-end frame loss"
|
||
::= { sleY1731MepEntry 46 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossFarRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the ratio of dual-ended far-end frame loss"
|
||
::= { sleY1731MepEntry 47 }
|
||
|
||
|
||
sleY1731MepCcmFrameLossFarAvgRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the average ratio of dual-ended far-end frame loss"
|
||
::= { sleY1731MepEntry 48 }
|
||
|
||
|
||
sleY1731MepRllcf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP is a MEP of client link for remote link loss carry forward."
|
||
::= { sleY1731MepEntry 49 }
|
||
|
||
|
||
sleY1731MepRllcfHoldOff OBJECT-TYPE
|
||
SYNTAX Integer32 (10..3000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"It is a Hold-off time of Remote LLCF and its unit is millisecond, interval is 10ms."
|
||
::= { sleY1731MepEntry 50 }
|
||
|
||
|
||
sleY1731MepRllcfGuardTime OBJECT-TYPE
|
||
SYNTAX Integer32 (100..10000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"It is a Guard time of Remote LLCF and its unit is millisecond, interval is 100ms.(default:500)"
|
||
::= { sleY1731MepEntry 51 }
|
||
|
||
|
||
sleY1731MepControl OBJECT IDENTIFIER ::= { sleY1731Mep 2 }
|
||
|
||
|
||
sleY1731MepControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731Mep(1),
|
||
deleteY1731Mep(2),
|
||
setY1731MepEnable(3),
|
||
setY1731MepCcEnable(4),
|
||
setY1731MepFaultProfile(5),
|
||
setY1731MepAisEnable(6),
|
||
setY1731MepAisTransmitEnable(7),
|
||
setY1731MepLckEnable(8),
|
||
setY1731MepLckTransmitEnable(9),
|
||
setY1731MepOutOfService(10),
|
||
setY1731MepDlmEnable(11),
|
||
transmitY1731Lbm(12),
|
||
transmitY1731Ltm(13),
|
||
transmitY1731TstLbm(14),
|
||
transmitY1731TmLbm(15),
|
||
transmitY1731Tst(16),
|
||
receiveY1731Tst(17),
|
||
transmitY1731TmTst(18),
|
||
receiveY1731TmTst(19),
|
||
transmitY1731Lmm(20),
|
||
transmitY17311dm(21),
|
||
receiveY17311dm(22),
|
||
transmitY1731dmm(23),
|
||
setY1731MepPmEnable(24),
|
||
setY1731MepRllcf(25)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MepControl 1 }
|
||
|
||
|
||
sleY1731MepControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MepControl 2 }
|
||
|
||
|
||
sleY1731MepControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MepControl 3 }
|
||
|
||
|
||
sleY1731MepControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MepControl 4 }
|
||
|
||
|
||
sleY1731MepControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MepControl 5 }
|
||
|
||
|
||
sleY1731MepControlIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MEP Id"
|
||
::= { sleY1731MepControl 6 }
|
||
|
||
|
||
sleY1731MepControlMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A index of MEG table"
|
||
::= { sleY1731MepControl 7 }
|
||
|
||
|
||
sleY1731MepControlIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Bridge Port Index whitch the MEP is attached"
|
||
::= { sleY1731MepControl 8 }
|
||
|
||
|
||
sleY1731MepControlDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
down(0),
|
||
up(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The direction in which the MEP faces on the Bridge port"
|
||
::= { sleY1731MepControl 9 }
|
||
|
||
|
||
sleY1731MepControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Administrative state of the MEP"
|
||
::= { sleY1731MepControl 10 }
|
||
|
||
|
||
sleY1731MepControlCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP will generate CCM messages"
|
||
::= { sleY1731MepControl 11 }
|
||
|
||
|
||
sleY1731MepControlFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdi(1),
|
||
loc(2),
|
||
unp(3),
|
||
unm(4),
|
||
mmg(5),
|
||
unl(6),
|
||
ais(7),
|
||
lck(8)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
|
||
::= { sleY1731MepControl 12 }
|
||
|
||
|
||
sleY1731MepControlFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be present before a Fault Alarm is issued"
|
||
::= { sleY1731MepControl 13 }
|
||
|
||
|
||
sleY1731MepControlFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be absent before resetting a Fault Alarm"
|
||
::= { sleY1731MepControl 14 }
|
||
|
||
|
||
sleY1731MepControlAisEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the AIS function for the MEP is enabled"
|
||
::= { sleY1731MepControl 15 }
|
||
|
||
|
||
sleY1731MepControlAisTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP can generate AIS messages"
|
||
::= { sleY1731MepControl 16 }
|
||
|
||
|
||
sleY1731MepControlLckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the LCK function for the MEP is enabled"
|
||
::= { sleY1731MepControl 17 }
|
||
|
||
|
||
sleY1731MepControlLckTransmitEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP can generate LCK messages"
|
||
::= { sleY1731MepControl 18 }
|
||
|
||
|
||
sleY1731MepControlOutOfService OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP is in out-of-service."
|
||
::= { sleY1731MepControl 19 }
|
||
|
||
|
||
sleY1731MepControlDlmEnabledRmep OBJECT-TYPE
|
||
SYNTAX Integer32 (0..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RMEP identifier enabled DLM functin
|
||
If set to zero, disabled DLM function.
|
||
"
|
||
::= { sleY1731MepControl 20 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmIsUnicast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates transmitting unicast or multicast frame"
|
||
::= { sleY1731MepControl 21 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmDestMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Target MAC Address Field to be transmitted"
|
||
::= { sleY1731MepControl 22 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
|
||
::= { sleY1731MepControl 23 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmDestIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"True indicates that MEPID of the target MEP is used for Loopback transmission"
|
||
::= { sleY1731MepControl 24 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmCount OBJECT-TYPE
|
||
SYNTAX Integer32 (1..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of Loopback messages to be transmitted"
|
||
::= { sleY1731MepControl 25 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval for sending LBM"
|
||
::= { sleY1731MepControl 26 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the waiting time for receiving the expected LBR"
|
||
::= { sleY1731MepControl 27 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 28 }
|
||
|
||
|
||
sleY1731MepControlTransmitLbmLength OBJECT-TYPE
|
||
SYNTAX Integer32 (5..1400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the length of Data TLV"
|
||
::= { sleY1731MepControl 29 }
|
||
|
||
|
||
sleY1731MepControlTransmitLtmTargetMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Target MAC Address Field to be transmitted: A unicast destination MAC address."
|
||
::= { sleY1731MepControl 30 }
|
||
|
||
|
||
sleY1731MepControlTransmitLtmTargetMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An indication of the Target MAC Address Field to be transmitted"
|
||
::= { sleY1731MepControl 31 }
|
||
|
||
|
||
sleY1731MepControlTransmitLtmTargetIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"True indicates that MEPID of the target MEP is used for Linktrace transmission."
|
||
::= { sleY1731MepControl 32 }
|
||
|
||
|
||
sleY1731MepControlTransmitLtmFlags OBJECT-TYPE
|
||
SYNTAX BITS { useFDBonly(0) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The flags field for LTMs transmitted by the MEP"
|
||
::= { sleY1731MepControl 33 }
|
||
|
||
|
||
sleY1731MepControlTransmitLtmTtl OBJECT-TYPE
|
||
SYNTAX Integer32 (1..64)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The LTM TTL field"
|
||
::= { sleY1731MepControl 34 }
|
||
|
||
|
||
sleY1731MepControlTransmitLtmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 35 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLbmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
|
||
::= { sleY1731MepControl 36 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLbmDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to send LBM"
|
||
::= { sleY1731MepControl 37 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLbmInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval for sending LBM"
|
||
::= { sleY1731MepControl 38 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLbmTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the waiting time for receiving the expected LBR"
|
||
::= { sleY1731MepControl 39 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLbmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 40 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLbmLength OBJECT-TYPE
|
||
SYNTAX Integer32 (5..1400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the length of Test TLV"
|
||
::= { sleY1731MepControl 41 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLbmPattern OBJECT-TYPE
|
||
SYNTAX Integer32 (0..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the pattern of Test TLV used for diagnostic test"
|
||
::= { sleY1731MepControl 42 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
|
||
::= { sleY1731MepControl 43 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to send LBM"
|
||
::= { sleY1731MepControl 44 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmPartDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (1..5)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the part duration of LBM to be transmitted at the same transmission rate"
|
||
::= { sleY1731MepControl 45 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmStartRate OBJECT-TYPE
|
||
SYNTAX Integer32 (100..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the the number of LBMs to be transmitted per second at first time"
|
||
::= { sleY1731MepControl 46 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmIncRate OBJECT-TYPE
|
||
SYNTAX Integer32 (100..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the increment of number of LBMs to be transmitted"
|
||
::= { sleY1731MepControl 47 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the waiting time for receiving the expected LBR"
|
||
::= { sleY1731MepControl 48 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 49 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmLength OBJECT-TYPE
|
||
SYNTAX Integer32 (5..1400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the length of Test TLV"
|
||
::= { sleY1731MepControl 50 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmLbmPattern OBJECT-TYPE
|
||
SYNTAX Integer32 (0..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the pattern of Test TLV used for diagnostic test"
|
||
::= { sleY1731MepControl 51 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstIsUnicast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates transmitting unicast or multicast frame"
|
||
::= { sleY1731MepControl 52 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the TST is to be sent"
|
||
::= { sleY1731MepControl 53 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to send TST"
|
||
::= { sleY1731MepControl 54 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval for sending TST"
|
||
::= { sleY1731MepControl 55 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 56 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstLength OBJECT-TYPE
|
||
SYNTAX Integer32 (5..1400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the length of Test TLV"
|
||
::= { sleY1731MepControl 57 }
|
||
|
||
|
||
sleY1731MepControlTransmitTstPattern OBJECT-TYPE
|
||
SYNTAX Integer32 (0..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the pattern of Test TLV used for diagnostic test"
|
||
::= { sleY1731MepControl 58 }
|
||
|
||
|
||
sleY1731MepControlReceiveTstDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to receive TST"
|
||
::= { sleY1731MepControl 59 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstIsUnicast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates transmitting unicast or multicast frame"
|
||
::= { sleY1731MepControl 60 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the TST is to be sent"
|
||
::= { sleY1731MepControl 61 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to send TST"
|
||
::= { sleY1731MepControl 62 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstPartDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (1..5)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the part duration of TST to be transmitted at the same transmission rate"
|
||
::= { sleY1731MepControl 63 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstStartRate OBJECT-TYPE
|
||
SYNTAX Integer32 (100..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the the number of TSTs to be transmitted per second at first time"
|
||
::= { sleY1731MepControl 64 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstIncRate OBJECT-TYPE
|
||
SYNTAX Integer32 (100..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the increment of number of TSTs to be transmitted"
|
||
::= { sleY1731MepControl 65 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the waiting time for receiving the expected LBR"
|
||
::= { sleY1731MepControl 66 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 67 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstLength OBJECT-TYPE
|
||
SYNTAX Integer32 (5..1400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the length of Test TLV"
|
||
::= { sleY1731MepControl 68 }
|
||
|
||
|
||
sleY1731MepControlTransmitTmTstPattern OBJECT-TYPE
|
||
SYNTAX Integer32 (0..3)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the pattern of Test TLV used for diagnostic test"
|
||
::= { sleY1731MepControl 69 }
|
||
|
||
|
||
sleY1731MepControlReceiveTmTstDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to receive TST"
|
||
::= { sleY1731MepControl 70 }
|
||
|
||
|
||
sleY1731MepControlTransmitLmmIsUnicast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A flag to indicates transmitting unicast or multicast frame"
|
||
::= { sleY1731MepControl 71 }
|
||
|
||
|
||
sleY1731MepControlTransmitLmmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LMM is to be sent"
|
||
::= { sleY1731MepControl 72 }
|
||
|
||
|
||
sleY1731MepControlTransmitLmmDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to send LMM"
|
||
::= { sleY1731MepControl 73 }
|
||
|
||
|
||
sleY1731MepControlTransmitLmmInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval for sending LMM"
|
||
::= { sleY1731MepControl 74 }
|
||
|
||
|
||
sleY1731MepControlTransmitLmmTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the waiting time for receiving the expected LMM"
|
||
::= { sleY1731MepControl 75 }
|
||
|
||
|
||
sleY1731MepControlTransmitLmmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 76 }
|
||
|
||
|
||
sleY1731MepControlTransmit1dmIsUnicast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A flag to indicates transmitting unicast or multicast frame"
|
||
::= { sleY1731MepControl 77 }
|
||
|
||
|
||
sleY1731MepControlTransmit1dmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the 1DM is to be sent"
|
||
::= { sleY1731MepControl 78 }
|
||
|
||
|
||
sleY1731MepControlTransmit1dmDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to send 1DM"
|
||
::= { sleY1731MepControl 79 }
|
||
|
||
|
||
sleY1731MepControlTransmit1dmInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval for sending 1DM"
|
||
::= { sleY1731MepControl 80 }
|
||
|
||
|
||
sleY1731MepControlTransmit1dmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 81 }
|
||
|
||
|
||
sleY1731MepControlReceive1dmDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to receive 1DM"
|
||
::= { sleY1731MepControl 82 }
|
||
|
||
|
||
sleY1731MepControlTransmitDmmIsUnicast OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A flag to indicates transmitting unicast or multicast frame"
|
||
::= { sleY1731MepControl 83 }
|
||
|
||
|
||
sleY1731MepControlTransmitDmmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the DMM is to be sent"
|
||
::= { sleY1731MepControl 84 }
|
||
|
||
|
||
sleY1731MepControlTransmitDmmDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the duration to send DMM"
|
||
::= { sleY1731MepControl 85 }
|
||
|
||
|
||
sleY1731MepControlTransmitDmmInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval for sending DMM"
|
||
::= { sleY1731MepControl 86 }
|
||
|
||
|
||
sleY1731MepControlTransmitDmmTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the waiting time for receiving the expected DMM"
|
||
::= { sleY1731MepControl 87 }
|
||
|
||
|
||
sleY1731MepControlTransmitDmmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleY1731MepControl 88 }
|
||
|
||
|
||
sleY1731MepControlPmEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the PM(performance monitoring) of the MEP is enabled"
|
||
::= { sleY1731MepControl 89 }
|
||
|
||
|
||
sleY1731MepControlRllcf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP is a MEP of client link for remote link loss carry forward."
|
||
::= { sleY1731MepControl 90 }
|
||
|
||
|
||
sleY1731MepControlRllcfHoldOff OBJECT-TYPE
|
||
SYNTAX Integer32 (10..3000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"It is a Hold-off time of Remote LLCF and its unit is millisecond, interval is 10ms."
|
||
::= { sleY1731MepControl 91 }
|
||
|
||
|
||
sleY1731MepControlRllcfGuardTime OBJECT-TYPE
|
||
SYNTAX Integer32 (100..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"It is a Guard time of Remote LLCF and its unit is millisecond, interval is 100ms.(default:500)"
|
||
::= { sleY1731MepControl 92 }
|
||
|
||
|
||
sleY1731MepNotification OBJECT IDENTIFIER ::= { sleY1731Mep 3 }
|
||
|
||
|
||
sleY1731MepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlIfIndex, sleY1731MepControlDirection }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731Mep"
|
||
::= { sleY1731MepNotification 1 }
|
||
|
||
|
||
sleY1731MepDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731Mep"
|
||
::= { sleY1731MepNotification 2 }
|
||
|
||
|
||
sleY1731MepEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731MepEnable"
|
||
::= { sleY1731MepNotification 3 }
|
||
|
||
|
||
sleY1731MepCcEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlCcEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731CcEnable"
|
||
::= { sleY1731MepNotification 4 }
|
||
|
||
|
||
sleY1731MepFaultProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlFaultPriority, sleY1731MepControlFaultKeepTime, sleY1731MepControlFaultClearTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731FaultProfile"
|
||
::= { sleY1731MepNotification 5 }
|
||
|
||
|
||
sleY1731MepAisEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlAisEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731AisEnable"
|
||
::= { sleY1731MepNotification 6 }
|
||
|
||
|
||
sleY1731MepAisTransmitEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlAisTransmitEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731AisTransmitEnable"
|
||
::= { sleY1731MepNotification 7 }
|
||
|
||
|
||
sleY1731MepLckEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlLckEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731LckEnable"
|
||
::= { sleY1731MepNotification 8 }
|
||
|
||
|
||
sleY1731MepLckTransmitEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlLckTransmitEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731LckTransmitEnable"
|
||
::= { sleY1731MepNotification 9 }
|
||
|
||
|
||
sleY1731MepOutOfServiceChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlOutOfService }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731OutOfService"
|
||
::= { sleY1731MepNotification 10 }
|
||
|
||
|
||
sleY1731MepDlmEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlDlmEnabledRmep }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731DlmEnable"
|
||
::= { sleY1731MepNotification 11 }
|
||
|
||
|
||
sleY1731MepTransmitLbmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731Lbm"
|
||
::= { sleY1731MepNotification 12 }
|
||
|
||
|
||
sleY1731MepTransmitLtmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731Ltm"
|
||
::= { sleY1731MepNotification 13 }
|
||
|
||
|
||
sleY1731MepTransmitTstLbmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731TstLbm"
|
||
::= { sleY1731MepNotification 14 }
|
||
|
||
|
||
sleY1731MepTransmitTmLbmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731TmLbm"
|
||
::= { sleY1731MepNotification 15 }
|
||
|
||
|
||
sleY1731MepTransmitTstFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731Tst"
|
||
::= { sleY1731MepNotification 16 }
|
||
|
||
|
||
sleY1731MepReceiveTstFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"receiveY1731Tst"
|
||
::= { sleY1731MepNotification 17 }
|
||
|
||
|
||
sleY1731MepTransmitTmTstFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731TmTst"
|
||
::= { sleY1731MepNotification 18 }
|
||
|
||
|
||
sleY1731MepReceiveTmTstFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"receiveY1731TmTst"
|
||
::= { sleY1731MepNotification 19 }
|
||
|
||
|
||
sleY1731MepTransmitLmmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731Lmm"
|
||
::= { sleY1731MepNotification 20 }
|
||
|
||
|
||
sleY1731MepTransmit1dmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY17311dm"
|
||
::= { sleY1731MepNotification 21 }
|
||
|
||
|
||
sleY1731MepReceive1dmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"receiveY17311dm"
|
||
::= { sleY1731MepNotification 22 }
|
||
|
||
|
||
sleY1731MepTransmitDmmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"transmitY1731Dmm"
|
||
::= { sleY1731MepNotification 23 }
|
||
|
||
|
||
sleY1731MepPmEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlPmEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731PmEnable"
|
||
::= { sleY1731MepNotification 24 }
|
||
|
||
|
||
sleY1731MepRllcfChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
|
||
sleY1731MepControlRllcf, sleY1731MepControlRllcfHoldOff, sleY1731MepControlRllcfGuardTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731MepRllcf"
|
||
::= { sleY1731MepNotification 25 }
|
||
|
||
|
||
sleY1731Mip OBJECT IDENTIFIER ::= { sleY1731Oam 4 }
|
||
|
||
|
||
sleY1731MipTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731MipEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731Mip 1 }
|
||
|
||
|
||
sleY1731MipEntry OBJECT-TYPE
|
||
SYNTAX SleY1731MipEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MipPort }
|
||
::= { sleY1731MipTable 1 }
|
||
|
||
|
||
SleY1731MipEntry ::=
|
||
SEQUENCE {
|
||
sleY1731MipPort
|
||
Integer32,
|
||
sleY1731MipLevel
|
||
Integer32,
|
||
sleY1731MipType
|
||
INTEGER
|
||
}
|
||
|
||
sleY1731MipPort OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port number"
|
||
::= { sleY1731MipEntry 1 }
|
||
|
||
|
||
sleY1731MipLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MIP's level"
|
||
::= { sleY1731MipEntry 2 }
|
||
|
||
|
||
sleY1731MipType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
static(1),
|
||
dynamic(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate the MIP<49><50>s type"
|
||
::= { sleY1731MipEntry 3 }
|
||
|
||
|
||
sleY1731MipControl OBJECT IDENTIFIER ::= { sleY1731Mip 2 }
|
||
|
||
|
||
sleY1731MipControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731Mip(1),
|
||
deleteY1731Mip(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MipControl 1 }
|
||
|
||
|
||
sleY1731MipControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MipControl 2 }
|
||
|
||
|
||
sleY1731MipControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MipControl 3 }
|
||
|
||
|
||
sleY1731MipControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MipControl 4 }
|
||
|
||
|
||
sleY1731MipControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MipControl 5 }
|
||
|
||
|
||
sleY1731MipControlPort OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port number"
|
||
::= { sleY1731MipControl 6 }
|
||
|
||
|
||
sleY1731MipControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MIP's level"
|
||
::= { sleY1731MipControl 7 }
|
||
|
||
|
||
sleY1731MipNotification OBJECT IDENTIFIER ::= { sleY1731Mip 3 }
|
||
|
||
|
||
sleY1731MipCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MipControlRequest, sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort, sleY1731MipControlLevel
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731Mip"
|
||
::= { sleY1731MipNotification 1 }
|
||
|
||
|
||
sleY1731MipDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731MipControlRequest, sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731Mip"
|
||
::= { sleY1731MipNotification 2 }
|
||
|
||
|
||
sleY1731Xcheck OBJECT IDENTIFIER ::= { sleY1731Oam 5 }
|
||
|
||
|
||
sleY1731XcheckTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731XcheckEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731Xcheck 1 }
|
||
|
||
|
||
sleY1731XcheckEntry OBJECT-TYPE
|
||
SYNTAX SleY1731XcheckEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731XcheckMepIdentifier }
|
||
::= { sleY1731XcheckTable 1 }
|
||
|
||
|
||
SleY1731XcheckEntry ::=
|
||
SEQUENCE {
|
||
sleY1731XcheckMepIdentifier
|
||
Integer32,
|
||
sleY1731XcheckMepState
|
||
INTEGER
|
||
}
|
||
|
||
sleY1731XcheckMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the remote MEP's Id"
|
||
::= { sleY1731XcheckEntry 1 }
|
||
|
||
|
||
sleY1731XcheckMepState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(0),
|
||
missing(1),
|
||
up(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the cross-check MEP<45><50>s state"
|
||
::= { sleY1731XcheckEntry 2 }
|
||
|
||
|
||
sleY1731XcheckControl OBJECT IDENTIFIER ::= { sleY1731Xcheck 2 }
|
||
|
||
|
||
sleY1731XcheckControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731XcheckMep(1),
|
||
deleteY1731XcheckMep(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731XcheckControl 1 }
|
||
|
||
|
||
sleY1731XcheckControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731XcheckControl 2 }
|
||
|
||
|
||
sleY1731XcheckControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731XcheckControl 3 }
|
||
|
||
|
||
sleY1731XcheckControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731XcheckControl 4 }
|
||
|
||
|
||
sleY1731XcheckControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731XcheckControl 5 }
|
||
|
||
|
||
sleY1731XcheckControlMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the remote MEP's Id"
|
||
::= { sleY1731XcheckControl 6 }
|
||
|
||
|
||
sleY1731XcheckControlMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG<45><47>s Index"
|
||
::= { sleY1731XcheckControl 7 }
|
||
|
||
|
||
sleY1731XcheckNotification OBJECT IDENTIFIER ::= { sleY1731Xcheck 3 }
|
||
|
||
|
||
sleY1731XcheckMepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731XcheckControlRequest, sleY1731XcheckControlTimeStamp, sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731XcheckMep"
|
||
::= { sleY1731XcheckNotification 1 }
|
||
|
||
|
||
sleY1731XcheckMepDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731XcheckControlRequest, sleY1731XcheckControlTimeStamp, sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731XcheckMep"
|
||
::= { sleY1731XcheckNotification 2 }
|
||
|
||
|
||
sleY1731CcMac OBJECT IDENTIFIER ::= { sleY1731Oam 6 }
|
||
|
||
|
||
sleY1731CcMacTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731CcMacEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731CcMac 1 }
|
||
|
||
|
||
sleY1731CcMacEntry OBJECT-TYPE
|
||
SYNTAX SleY1731CcMacEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731CcMacAddress }
|
||
::= { sleY1731CcMacTable 1 }
|
||
|
||
|
||
SleY1731CcMacEntry ::=
|
||
SEQUENCE {
|
||
sleY1731CcMacAddress
|
||
OCTET STRING
|
||
}
|
||
|
||
sleY1731CcMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the unicast MAC address to send CCM"
|
||
::= { sleY1731CcMacEntry 1 }
|
||
|
||
|
||
sleY1731CcMacControl OBJECT IDENTIFIER ::= { sleY1731CcMac 2 }
|
||
|
||
|
||
sleY1731CcMacControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731CcMac(1),
|
||
deleteY1731CcMac(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731CcMacControl 1 }
|
||
|
||
|
||
sleY1731CcMacControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731CcMacControl 2 }
|
||
|
||
|
||
sleY1731CcMacControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731CcMacControl 3 }
|
||
|
||
|
||
sleY1731CcMacControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731CcMacControl 4 }
|
||
|
||
|
||
sleY1731CcMacControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result of the last command."
|
||
::= { sleY1731CcMacControl 5 }
|
||
|
||
|
||
sleY1731CcMacControlMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index"
|
||
::= { sleY1731CcMacControl 6 }
|
||
|
||
|
||
sleY1731CcMacControlMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MEP Id"
|
||
::= { sleY1731CcMacControl 7 }
|
||
|
||
|
||
sleY1731CcMacControlAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the unicast MAC address to send CCM
|
||
When running deleteY1731CcMac, if this is zero-length, delete all unicast mac."
|
||
::= { sleY1731CcMacControl 8 }
|
||
|
||
|
||
sleY1731CcMacNotification OBJECT IDENTIFIER ::= { sleY1731CcMac 3 }
|
||
|
||
|
||
sleY1731CcMacCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731CcMacControlRequest, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex, sleY1731CcMacControlMepIdentifier,
|
||
sleY1731CcMacControlAddress }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731CcMac"
|
||
::= { sleY1731CcMacNotification 1 }
|
||
|
||
|
||
sleY1731CcMacDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731CcMacControlRequest, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex, sleY1731CcMacControlMepIdentifier,
|
||
sleY1731CcMacControlAddress }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731CcMac"
|
||
::= { sleY1731CcMacNotification 2 }
|
||
|
||
|
||
sleY1731AisMac OBJECT IDENTIFIER ::= { sleY1731Oam 7 }
|
||
|
||
|
||
sleY1731AisMacTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731AisMacEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731AisMac 1 }
|
||
|
||
|
||
sleY1731AisMacEntry OBJECT-TYPE
|
||
SYNTAX SleY1731AisMacEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731AisMacAddress }
|
||
::= { sleY1731AisMacTable 1 }
|
||
|
||
|
||
SleY1731AisMacEntry ::=
|
||
SEQUENCE {
|
||
sleY1731AisMacAddress
|
||
OCTET STRING
|
||
}
|
||
|
||
sleY1731AisMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the unicast MAC address to send AIS"
|
||
::= { sleY1731AisMacEntry 1 }
|
||
|
||
|
||
sleY1731AisMacControl OBJECT IDENTIFIER ::= { sleY1731AisMac 2 }
|
||
|
||
|
||
sleY1731AisMacControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731AisMac(1),
|
||
deleteY1731AisMac(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731AisMacControl 1 }
|
||
|
||
|
||
sleY1731AisMacControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731AisMacControl 2 }
|
||
|
||
|
||
sleY1731AisMacControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731AisMacControl 3 }
|
||
|
||
|
||
sleY1731AisMacControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731AisMacControl 4 }
|
||
|
||
|
||
sleY1731AisMacControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731AisMacControl 5 }
|
||
|
||
|
||
sleY1731AisMacControlMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index"
|
||
::= { sleY1731AisMacControl 6 }
|
||
|
||
|
||
sleY1731AisMacControlMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MEP Id"
|
||
::= { sleY1731AisMacControl 7 }
|
||
|
||
|
||
sleY1731AisMacControlAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the unicast MAC address to send AIS
|
||
When running deleteY1731AisMac, if this is zero-length, delete all unicast mac."
|
||
::= { sleY1731AisMacControl 8 }
|
||
|
||
|
||
sleY1731AisMacNotification OBJECT IDENTIFIER ::= { sleY1731AisMac 3 }
|
||
|
||
|
||
sleY1731AisMacCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731AisMacControlRequest, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier,
|
||
sleY1731AisMacControlAddress }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731AisMac"
|
||
::= { sleY1731AisMacNotification 1 }
|
||
|
||
|
||
sleY1731AisMacDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731AisMacControlRequest, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier,
|
||
sleY1731AisMacControlAddress }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731AisMac"
|
||
::= { sleY1731AisMacNotification 2 }
|
||
|
||
|
||
sleY1731LckMac OBJECT IDENTIFIER ::= { sleY1731Oam 8 }
|
||
|
||
|
||
sleY1731LckMacTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731LckMacEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LckMac 1 }
|
||
|
||
|
||
sleY1731LckMacEntry OBJECT-TYPE
|
||
SYNTAX SleY1731LckMacEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LckMacAddress }
|
||
::= { sleY1731LckMacTable 1 }
|
||
|
||
|
||
SleY1731LckMacEntry ::=
|
||
SEQUENCE {
|
||
sleY1731LckMacAddress
|
||
OCTET STRING
|
||
}
|
||
|
||
sleY1731LckMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the unicast MAC address to send LCK"
|
||
::= { sleY1731LckMacEntry 1 }
|
||
|
||
|
||
sleY1731LckMacControl OBJECT IDENTIFIER ::= { sleY1731LckMac 2 }
|
||
|
||
|
||
sleY1731LckMacControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731LckMac(1),
|
||
deleteY1731LckMac(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LckMacControl 1 }
|
||
|
||
|
||
sleY1731LckMacControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LckMacControl 2 }
|
||
|
||
|
||
sleY1731LckMacControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LckMacControl 3 }
|
||
|
||
|
||
sleY1731LckMacControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LckMacControl 4 }
|
||
|
||
|
||
sleY1731LckMacControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LckMacControl 5 }
|
||
|
||
|
||
sleY1731LckMacControlMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index"
|
||
::= { sleY1731LckMacControl 6 }
|
||
|
||
|
||
sleY1731LckMacControlMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MEP Id"
|
||
::= { sleY1731LckMacControl 7 }
|
||
|
||
|
||
sleY1731LckMacControlAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the unicast MAC address to send LCK
|
||
When running deleteY1731LckMac, if this is zero-length, delete all unicast mac."
|
||
::= { sleY1731LckMacControl 8 }
|
||
|
||
|
||
sleY1731LckMacNotification OBJECT IDENTIFIER ::= { sleY1731LckMac 3 }
|
||
|
||
|
||
sleY1731LckMacCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731LckMacControlRequest, sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier,
|
||
sleY1731LckMacControlAddress }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731LckMac"
|
||
::= { sleY1731LckMacNotification 1 }
|
||
|
||
|
||
sleY1731LckMacDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731LckMacControlRequest, sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier,
|
||
sleY1731LckMacControlAddress }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731LckMac"
|
||
::= { sleY1731LckMacNotification 2 }
|
||
|
||
|
||
sleY1731Rmep OBJECT IDENTIFIER ::= { sleY1731Oam 9 }
|
||
|
||
|
||
sleY1731RmepTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731RmepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731Rmep 1 }
|
||
|
||
|
||
sleY1731RmepEntry OBJECT-TYPE
|
||
SYNTAX SleY1731RmepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731RmepIdentifier }
|
||
::= { sleY1731RmepTable 1 }
|
||
|
||
|
||
SleY1731RmepEntry ::=
|
||
SEQUENCE {
|
||
sleY1731RmepIdentifier
|
||
Integer32,
|
||
sleY1731RmepState
|
||
INTEGER,
|
||
sleY1731RmepFailedOkTime
|
||
TimeTicks,
|
||
sleY1731RmepMacAddress
|
||
OCTET STRING,
|
||
sleY1731RmepIfIndex
|
||
Integer32,
|
||
sleY1731RmepRdi
|
||
INTEGER,
|
||
sleY1731RmepLoc
|
||
INTEGER,
|
||
sleY1731RmepReceiveTstCount
|
||
Counter32,
|
||
sleY1731RmepReceiveTstOutOfOrder
|
||
Counter32,
|
||
sleY1731RmepReceiveTstBitError
|
||
Counter32,
|
||
sleY1731RmepReceiveTstCrcError
|
||
Counter32,
|
||
sleY1731RmepReceiveTmTstCount
|
||
Counter32,
|
||
sleY1731RmepReceiveTmTstLostId
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossNearMin
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossNearMax
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossNearSum
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossFarMin
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossFarMax
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossFarSum
|
||
Integer32,
|
||
sleY1731RmepReceive1dmCount
|
||
Counter32,
|
||
sleY1731Rmep1dmFrameDelayMin
|
||
Integer32,
|
||
sleY1731Rmep1dmFrameDelayMax
|
||
Integer32,
|
||
sleY1731Rmep1dmFrameDelayAvg
|
||
Integer32,
|
||
sleY1731Rmep1dmFrameDelayVar
|
||
Integer32,
|
||
sleY1731RmepReceiveDmrCount
|
||
Counter32,
|
||
sleY1731RmepDmrFrameDelayMin
|
||
Integer32,
|
||
sleY1731RmepDmrFrameDelayMax
|
||
Integer32,
|
||
sleY1731RmepDmrFrameDelayAvg
|
||
Integer32,
|
||
sleY1731RmepDmrFrameDelayVar
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossNearRatio
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossNearAvgRatio
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossFarRatio
|
||
Integer32,
|
||
sleY1731RmepLmrFrameLossFarAvgRatio
|
||
Integer32
|
||
}
|
||
|
||
sleY1731RmepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the remote MEP's Id"
|
||
::= { sleY1731RmepEntry 1 }
|
||
|
||
|
||
sleY1731RmepState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
start(1),
|
||
failed(2),
|
||
ok(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the operational state of the remote MEP State machines"
|
||
::= { sleY1731RmepEntry 2 }
|
||
|
||
|
||
sleY1731RmepFailedOkTime OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time (SysUpTime) at which the Remote MEP state machine last entered either the RMEP_FAILED or RMEP_OK state."
|
||
::= { sleY1731RmepEntry 3 }
|
||
|
||
|
||
sleY1731RmepMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MAC address of the remote MEP"
|
||
::= { sleY1731RmepEntry 4 }
|
||
|
||
|
||
sleY1731RmepIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port number of the remote MEP"
|
||
::= { sleY1731RmepEntry 5 }
|
||
|
||
|
||
sleY1731RmepRdi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received"
|
||
::= { sleY1731RmepEntry 6 }
|
||
|
||
|
||
sleY1731RmepLoc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates Loss-of-continuity"
|
||
::= { sleY1731RmepEntry 7 }
|
||
|
||
|
||
sleY1731RmepReceiveTstCount OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of received TST frame"
|
||
::= { sleY1731RmepEntry 8 }
|
||
|
||
|
||
sleY1731RmepReceiveTstOutOfOrder OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of received out-of-order TST frame"
|
||
::= { sleY1731RmepEntry 9 }
|
||
|
||
|
||
sleY1731RmepReceiveTstBitError OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of received bit-error TST frame"
|
||
::= { sleY1731RmepEntry 10 }
|
||
|
||
|
||
sleY1731RmepReceiveTstCrcError OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of received crc-error TST frame"
|
||
::= { sleY1731RmepEntry 11 }
|
||
|
||
|
||
sleY1731RmepReceiveTmTstCount OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of received TST frame for the throughput-measurement"
|
||
::= { sleY1731RmepEntry 12 }
|
||
|
||
|
||
sleY1731RmepReceiveTmTstLostId OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the transaction identifier of first lost TST frame for the throughput-measurement"
|
||
::= { sleY1731RmepEntry 13 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossNearMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum of single-ended near-end frame loss"
|
||
::= { sleY1731RmepEntry 14 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossNearMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maximum of single-ended near-end frame loss"
|
||
::= { sleY1731RmepEntry 15 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossNearSum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the sum of single-ended near-end frame loss"
|
||
::= { sleY1731RmepEntry 16 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossFarMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum of single-ended far-end frame loss"
|
||
::= { sleY1731RmepEntry 17 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossFarMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maximum of single-ended far-end frame loss"
|
||
::= { sleY1731RmepEntry 18 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossFarSum OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the sum of single-ended far-end frame loss"
|
||
::= { sleY1731RmepEntry 19 }
|
||
|
||
|
||
sleY1731RmepReceive1dmCount OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of received 1DM frames for the frame delay measurement"
|
||
::= { sleY1731RmepEntry 20 }
|
||
|
||
|
||
sleY1731Rmep1dmFrameDelayMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum of one-way frame delay"
|
||
::= { sleY1731RmepEntry 21 }
|
||
|
||
|
||
sleY1731Rmep1dmFrameDelayMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maximum of one-way frame delay"
|
||
::= { sleY1731RmepEntry 22 }
|
||
|
||
|
||
sleY1731Rmep1dmFrameDelayAvg OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the average of one-way frame delay"
|
||
::= { sleY1731RmepEntry 23 }
|
||
|
||
|
||
sleY1731Rmep1dmFrameDelayVar OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the variation of one-way frame delay"
|
||
::= { sleY1731RmepEntry 24 }
|
||
|
||
|
||
sleY1731RmepReceiveDmrCount OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of received DMR frames for the frame delay measurement"
|
||
::= { sleY1731RmepEntry 25 }
|
||
|
||
|
||
sleY1731RmepDmrFrameDelayMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum of two-way frame delay"
|
||
::= { sleY1731RmepEntry 26 }
|
||
|
||
|
||
sleY1731RmepDmrFrameDelayMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maximum of two-way frame delay"
|
||
::= { sleY1731RmepEntry 27 }
|
||
|
||
|
||
sleY1731RmepDmrFrameDelayAvg OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the average of two-way frame delay"
|
||
::= { sleY1731RmepEntry 28 }
|
||
|
||
|
||
sleY1731RmepDmrFrameDelayVar OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the variation of two-way frame delay"
|
||
::= { sleY1731RmepEntry 29 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossNearRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the ratio of single-ended near-end frame loss"
|
||
::= { sleY1731RmepEntry 30 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossNearAvgRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the average ratio of single-ended near-end frame loss"
|
||
::= { sleY1731RmepEntry 31 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossFarRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the ratio of single-ended far-end frame loss"
|
||
::= { sleY1731RmepEntry 32 }
|
||
|
||
|
||
sleY1731RmepLmrFrameLossFarAvgRatio OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the average ratio of single-ended far-end frame loss"
|
||
::= { sleY1731RmepEntry 33 }
|
||
|
||
|
||
sleY1731RmepControl OBJECT IDENTIFIER ::= { sleY1731Rmep 2 }
|
||
|
||
|
||
sleY1731RmepControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731Rmep(1),
|
||
deleteY1731Rmep(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731RmepControl 1 }
|
||
|
||
|
||
sleY1731RMepControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731RmepControl 2 }
|
||
|
||
|
||
sleY1731RmepControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731RmepControl 3 }
|
||
|
||
|
||
sleY1731RmepControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731RmepControl 4 }
|
||
|
||
|
||
sleY1731RmepControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731RmepControl 5 }
|
||
|
||
|
||
sleY1731RmepControlIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Remote MEP Id"
|
||
::= { sleY1731RmepControl 6 }
|
||
|
||
|
||
sleY1731RmepControlMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A index of MEG table"
|
||
::= { sleY1731RmepControl 7 }
|
||
|
||
|
||
sleY1731RmepControlIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Bridge Port Index whitch the MEP is attached"
|
||
::= { sleY1731RmepControl 8 }
|
||
|
||
|
||
sleY1731RmepNotification OBJECT IDENTIFIER ::= { sleY1731Rmep 3 }
|
||
|
||
|
||
sleY1731RmepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731RmepControlRequest, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier, sleY1731RmepControlMegIndex,
|
||
sleY1731RmepControlIfIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731RmepNotification 1 }
|
||
|
||
|
||
sleY1731RmepDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731RmepControlRequest, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier, sleY1731RmepControlMegIndex,
|
||
sleY1731RmepControlIfIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731RmepNotification 2 }
|
||
|
||
|
||
sleY1731LbrMcast OBJECT IDENTIFIER ::= { sleY1731Oam 10 }
|
||
|
||
|
||
sleY1731LbrMcastTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731LbrMcastEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LbrMcast 1 }
|
||
|
||
|
||
sleY1731LbrMcastEntry OBJECT-TYPE
|
||
SYNTAX SleY1731LbrMcastEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LbrReceiveOrder }
|
||
::= { sleY1731LbrMcastTable 1 }
|
||
|
||
|
||
SleY1731LbrMcastEntry ::=
|
||
SEQUENCE {
|
||
sleY1731LbrReceiveOrder
|
||
Integer32,
|
||
sleY1731LbrRemoteMacAddress
|
||
OCTET STRING
|
||
}
|
||
|
||
sleY1731LbrReceiveOrder OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates an index to distinguish among multiple LBRs"
|
||
::= { sleY1731LbrMcastEntry 1 }
|
||
|
||
|
||
sleY1731LbrRemoteMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MAC address of the remote MEP"
|
||
::= { sleY1731LbrMcastEntry 2 }
|
||
|
||
|
||
sleY1731LbrUcast OBJECT IDENTIFIER ::= { sleY1731Oam 11 }
|
||
|
||
|
||
sleY1731LbrUcastTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731LbrUcastEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LbrUcast 1 }
|
||
|
||
|
||
sleY1731LbrUcastEntry OBJECT-TYPE
|
||
SYNTAX SleY1731LbrUcastEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LbrTransId }
|
||
::= { sleY1731LbrUcastTable 1 }
|
||
|
||
|
||
SleY1731LbrUcastEntry ::=
|
||
SEQUENCE {
|
||
sleY1731LbrTransId
|
||
Integer32,
|
||
sleY1731LbrRoundTripTime
|
||
Integer32
|
||
}
|
||
|
||
sleY1731LbrTransId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the transaction identifier of LBR message."
|
||
::= { sleY1731LbrUcastEntry 1 }
|
||
|
||
|
||
sleY1731LbrRoundTripTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the round-trip time of LBR message."
|
||
::= { sleY1731LbrUcastEntry 2 }
|
||
|
||
|
||
sleY1731Ltr OBJECT IDENTIFIER ::= { sleY1731Oam 12 }
|
||
|
||
|
||
sleY1731LtrTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731LtrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731Ltr 1 }
|
||
|
||
|
||
sleY1731LtrEntry OBJECT-TYPE
|
||
SYNTAX SleY1731LtrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LtrSeqNumber, sleY1731LtrReceiveOrder }
|
||
::= { sleY1731LtrTable 1 }
|
||
|
||
|
||
SleY1731LtrEntry ::=
|
||
SEQUENCE {
|
||
sleY1731LtrSeqNumber
|
||
Integer32,
|
||
sleY1731LtrReceiveOrder
|
||
Integer32,
|
||
sleY1731LtrRoundTripTime
|
||
Integer32,
|
||
sleY1731LtrTtl
|
||
Integer32,
|
||
sleY1731LtrForwarded
|
||
INTEGER,
|
||
sleY1731LtrTerminalMep
|
||
INTEGER,
|
||
sleY1731LtrLastEgressIdentifier
|
||
OCTET STRING,
|
||
sleY1731LtrNextEgressIdentifier
|
||
OCTET STRING,
|
||
sleY1731LtrRelay
|
||
INTEGER,
|
||
sleY1731LtrIngress
|
||
INTEGER,
|
||
sleY1731LtrIngressMac
|
||
OCTET STRING,
|
||
sleY1731LtrIngressPort
|
||
Integer32,
|
||
sleY1731LtrEgress
|
||
INTEGER,
|
||
sleY1731LtrEgressMac
|
||
OCTET STRING,
|
||
sleY1731LtrEgressPort
|
||
Integer32
|
||
}
|
||
|
||
sleY1731LtrSeqNumber OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the LTM Transaction Identifier returned from a previous Transmit Linktrace Message command,
|
||
indicating the LTM entry to which the LTR entries will be attached
|
||
"
|
||
::= { sleY1731LtrEntry 1 }
|
||
|
||
|
||
sleY1731LtrReceiveOrder OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates an index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value"
|
||
::= { sleY1731LtrEntry 2 }
|
||
|
||
|
||
sleY1731LtrRoundTripTime OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the round-trip time of LTR message."
|
||
::= { sleY1731LtrEntry 3 }
|
||
|
||
|
||
sleY1731LtrTtl OBJECT-TYPE
|
||
SYNTAX Integer32 (1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates TTL field value for a returned LTR."
|
||
::= { sleY1731LtrEntry 4 }
|
||
|
||
|
||
sleY1731LtrForwarded OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field."
|
||
::= { sleY1731LtrEntry 5 }
|
||
|
||
|
||
sleY1731LtrTerminalMep OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates a boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field. "
|
||
::= { sleY1731LtrEntry 6 }
|
||
|
||
|
||
sleY1731LtrLastEgressIdentifier OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies the MEP Linktrace Initiator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response"
|
||
::= { sleY1731LtrEntry 7 }
|
||
|
||
|
||
sleY1731LtrNextEgressIdentifier OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop."
|
||
::= { sleY1731LtrEntry 8 }
|
||
|
||
|
||
sleY1731LtrRelay OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rlyHit(1),
|
||
rlyFDB(2),
|
||
rlyMPDB(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the value returned in the Ingress Action Field of the LTM"
|
||
::= { sleY1731LtrEntry 9 }
|
||
|
||
|
||
sleY1731LtrIngress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ingNoTlv(0),
|
||
ingOK(1),
|
||
ingDown(2),
|
||
ingBlocked(3),
|
||
ingVid(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the value returned in the Ingress Action Field of the LTM"
|
||
::= { sleY1731LtrEntry 10 }
|
||
|
||
|
||
sleY1731LtrIngressMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates MAC address returned in the ingress MAC address field."
|
||
::= { sleY1731LtrEntry 11 }
|
||
|
||
|
||
sleY1731LtrIngressPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates Ingress Port ID"
|
||
::= { sleY1731LtrEntry 12 }
|
||
|
||
|
||
sleY1731LtrEgress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
egrNoTlv(0),
|
||
egrOK(1),
|
||
egrDown(2),
|
||
egrBlocked(3),
|
||
egrVid(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the value returned in the Egress Action Field of the LTM"
|
||
::= { sleY1731LtrEntry 13 }
|
||
|
||
|
||
sleY1731LtrEgressMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates MAC address returned in the egress MAC address field."
|
||
::= { sleY1731LtrEntry 14 }
|
||
|
||
|
||
sleY1731LtrEgressPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates Egress Port ID"
|
||
::= { sleY1731LtrEntry 15 }
|
||
|
||
|
||
sleY1731ConfigError OBJECT IDENTIFIER ::= { sleY1731Oam 13 }
|
||
|
||
|
||
sleY1731ConfigErrorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731ConfigErrorEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731ConfigError 1 }
|
||
|
||
|
||
sleY1731ConfigErrorEntry OBJECT-TYPE
|
||
SYNTAX SleY1731ConfigErrorEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731ConfigErrorVid, sleY1731ConfigErrorIfIndex }
|
||
::= { sleY1731ConfigErrorTable 1 }
|
||
|
||
|
||
SleY1731ConfigErrorEntry ::=
|
||
SEQUENCE {
|
||
sleY1731ConfigErrorVid
|
||
Integer32,
|
||
sleY1731ConfigErrorIfIndex
|
||
Integer32,
|
||
sleY1731ConfigErrorType
|
||
BITS
|
||
}
|
||
|
||
sleY1731ConfigErrorVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Configuration Error VLAN Identifier"
|
||
::= { sleY1731ConfigErrorEntry 1 }
|
||
|
||
|
||
sleY1731ConfigErrorIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Configuration Error Port Number"
|
||
::= { sleY1731ConfigErrorEntry 2 }
|
||
|
||
|
||
sleY1731ConfigErrorType OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
y1731leak(0),
|
||
conflictingVids(1),
|
||
excessiveLevels(2),
|
||
overlappedLevels(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Configuration Error Type"
|
||
::= { sleY1731ConfigErrorEntry 3 }
|
||
|
||
|
||
sleY1731MipCcdb OBJECT IDENTIFIER ::= { sleY1731Oam 14 }
|
||
|
||
|
||
sleY1731MipCcdbTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731MipCcdbEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731MipCcdb 1 }
|
||
|
||
|
||
sleY1731MipCcdbEntry OBJECT-TYPE
|
||
SYNTAX SleY1731MipCcdbEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MipCcdbIndex }
|
||
::= { sleY1731MipCcdbTable 1 }
|
||
|
||
|
||
SleY1731MipCcdbEntry ::=
|
||
SEQUENCE {
|
||
sleY1731MipCcdbIndex
|
||
Integer32,
|
||
sleY1731MipCcdbVlanId
|
||
Integer32,
|
||
sleY1731MipCcdbMacAddr
|
||
OCTET STRING,
|
||
sleY1731MipCcdbPort
|
||
Integer32,
|
||
sleY1731MipCcdbKeepTime
|
||
TimeTicks
|
||
}
|
||
|
||
sleY1731MipCcdbIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MIP CCDB's Index"
|
||
::= { sleY1731MipCcdbEntry 1 }
|
||
|
||
|
||
sleY1731MipCcdbVlanId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"VLAN Id"
|
||
::= { sleY1731MipCcdbEntry 2 }
|
||
|
||
|
||
sleY1731MipCcdbMacAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates MAC address of the remote MEP"
|
||
::= { sleY1731MipCcdbEntry 3 }
|
||
|
||
|
||
sleY1731MipCcdbPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Port number that the CCM output"
|
||
::= { sleY1731MipCcdbEntry 4 }
|
||
|
||
|
||
sleY1731MipCcdbKeepTime OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates an up-date time of a entry"
|
||
::= { sleY1731MipCcdbEntry 5 }
|
||
|
||
|
||
sleY1731UplinkRedundancy OBJECT IDENTIFIER ::= { sleY1731Oam 15 }
|
||
|
||
|
||
sleY1731URTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731UREntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Y1731 Uplink-redundancy information table."
|
||
::= { sleY1731UplinkRedundancy 1 }
|
||
|
||
|
||
sleY1731UREntry OBJECT-TYPE
|
||
SYNTAX SleY1731UREntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"key: sleY1731URMegIndex"
|
||
INDEX { sleY1731URMegIndex }
|
||
::= { sleY1731URTable 1 }
|
||
|
||
|
||
SleY1731UREntry ::=
|
||
SEQUENCE {
|
||
sleY1731URMegIndex
|
||
INTEGER,
|
||
sleY1731URMegName
|
||
OCTET STRING,
|
||
sleY1731URDedicatedVlan
|
||
INTEGER,
|
||
sleY1731UREnableStatus
|
||
INTEGER,
|
||
sleY1731URConnectivityCheckMeg
|
||
OCTET STRING,
|
||
sleY1731URPrimaryMepId
|
||
INTEGER,
|
||
sleY1731URSecondaryMepId
|
||
INTEGER,
|
||
sleY1731URControlVlan
|
||
INTEGER,
|
||
sleY1731URNodeConf
|
||
INTEGER,
|
||
sleY1731URNodeConfPortNum
|
||
INTEGER,
|
||
sleY1731URNodeConfPortStatus
|
||
INTEGER,
|
||
sleY1731URNonRevertive
|
||
INTEGER,
|
||
sleY1731URTrustMemberCount
|
||
INTEGER,
|
||
sleY1731URWaitToRestore
|
||
INTEGER,
|
||
sleY1731URForceSwitch
|
||
INTEGER,
|
||
sleY1731URSFCondition
|
||
INTEGER,
|
||
sleY1731URTrafficVlan
|
||
OCTET STRING,
|
||
sleY1731URState
|
||
INTEGER,
|
||
sleY1731URManualSwitch
|
||
INTEGER
|
||
}
|
||
|
||
sleY1731URMegIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MEG index."
|
||
::= { sleY1731UREntry 1 }
|
||
|
||
|
||
sleY1731URMegName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MEG name."
|
||
::= { sleY1731UREntry 2 }
|
||
|
||
|
||
sleY1731URDedicatedVlan OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates R-APS node to use dedicated-VLAN
|
||
disable : all VLAN
|
||
enable : one VLAN"
|
||
::= { sleY1731UREntry 3 }
|
||
|
||
|
||
sleY1731UREnableStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Uplink-redundancy feature
|
||
0 : disable
|
||
1 : enable"
|
||
::= { sleY1731UREntry 4 }
|
||
|
||
|
||
sleY1731URConnectivityCheckMeg OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the connectivity check - MEG name."
|
||
::= { sleY1731UREntry 5 }
|
||
|
||
|
||
sleY1731URPrimaryMepId OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the connectivity check - primary MEP's ID"
|
||
::= { sleY1731UREntry 6 }
|
||
|
||
|
||
sleY1731URSecondaryMepId OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the connectivity check - secondary MEP's ID"
|
||
::= { sleY1731UREntry 7 }
|
||
|
||
|
||
sleY1731URControlVlan OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the control VLAN"
|
||
::= { sleY1731UREntry 8 }
|
||
|
||
|
||
sleY1731URNodeConf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
master(1),
|
||
slave(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the (master/slave) node of the redundancy"
|
||
::= { sleY1731UREntry 9 }
|
||
|
||
|
||
sleY1731URNodeConfPortNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The port number"
|
||
::= { sleY1731UREntry 10 }
|
||
|
||
|
||
sleY1731URNodeConfPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
disabled(1),
|
||
forwarding(2),
|
||
blocking(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The uplink port status
|
||
0: none
|
||
1: disabled
|
||
2: forwarding
|
||
3: blocking"
|
||
::= { sleY1731UREntry 11 }
|
||
|
||
|
||
sleY1731URNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
ture(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The non-revertive mode"
|
||
::= { sleY1731UREntry 12 }
|
||
|
||
|
||
sleY1731URTrustMemberCount OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the trust LOC count at link-aggregation port"
|
||
::= { sleY1731UREntry 13 }
|
||
|
||
|
||
sleY1731URWaitToRestore OBJECT-TYPE
|
||
SYNTAX INTEGER (5..720)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time ( 5 - 720 )"
|
||
::= { sleY1731UREntry 14 }
|
||
|
||
|
||
sleY1731URForceSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The forced-switch of uplink port
|
||
"
|
||
::= { sleY1731UREntry 15 }
|
||
|
||
|
||
sleY1731URSFCondition OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
loc(0),
|
||
locRdi(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The sf condition
|
||
"
|
||
::= { sleY1731UREntry 16 }
|
||
|
||
|
||
sleY1731URTrafficVlan OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Traffic vlan.
|
||
"
|
||
::= { sleY1731UREntry 17 }
|
||
|
||
|
||
sleY1731URState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unReady(0),
|
||
ready(1),
|
||
active(2),
|
||
standby(3),
|
||
preActive(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The uplink redundancy node state
|
||
none(0)
|
||
unReady(1)
|
||
ready(2)
|
||
active(3)
|
||
standby(4)
|
||
preActive(5)"
|
||
::= { sleY1731UREntry 18 }
|
||
|
||
|
||
sleY1731URManualSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The manual-switch of uplink port
|
||
"
|
||
::= { sleY1731UREntry 19 }
|
||
|
||
|
||
sleY1731URControl OBJECT IDENTIFIER ::= { sleY1731UplinkRedundancy 2 }
|
||
|
||
|
||
sleY1731URControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setDedicatedVlan(1),
|
||
setEnableStatus(2),
|
||
setCCPrimaryMepId(3),
|
||
clearCCPrimaryMepId(4),
|
||
setCCSecondaryMepId(5),
|
||
clearCCSecondaryMepId(6),
|
||
setControlVlan(7),
|
||
clearControlVlan(8),
|
||
setNodeConfiguration(9),
|
||
clearNodeConfiguration(10),
|
||
setNonRevertive(11),
|
||
setTrustMemberCount(12),
|
||
clearTrustMemberCount(13),
|
||
setWaitToRestore(14),
|
||
clearWaitToRestore(15),
|
||
setForceSwitch(16),
|
||
setManualSwitch(17),
|
||
setSFCondition(18),
|
||
setTrafficVlan(19),
|
||
clearTrafficVlan(20)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This attribute identifies the control commands.
|
||
updateAlarmList:
|
||
the NE updates entries of alarms in the sleAlarmListTable
|
||
after having changed alarm severities of alarms
|
||
(due to change profile pointers in
|
||
managed entities or after modification of alarm severities
|
||
in profiles). This command should be applied once after having
|
||
finisled modifications of severties.
|
||
modifyAlarmSeverity:
|
||
modifies the severity of an alarm in specific profile.
|
||
createAlarmSeverityProfile:
|
||
creates a new profile with default severities.
|
||
The severities then have to be modified with command changeAlarmSeverity.
|
||
deleteAlarmSeverityProfile:
|
||
deletes a profile. Profile 1 is not allowed to be deleted.
|
||
|
||
Notifications : none "
|
||
::= { sleY1731URControl 1 }
|
||
|
||
|
||
sleY1731URControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of a control request. "
|
||
::= { sleY1731URControl 2 }
|
||
|
||
|
||
sleY1731URControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleY1731URControl 3 }
|
||
|
||
|
||
sleY1731URControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleY1731URControl 4 }
|
||
|
||
|
||
sleY1731URControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The result of the last user command. "
|
||
::= { sleY1731URControl 5 }
|
||
|
||
|
||
sleY1731URControlMegIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MEG index."
|
||
::= { sleY1731URControl 6 }
|
||
|
||
|
||
sleY1731URControlMegName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MEG name."
|
||
::= { sleY1731URControl 7 }
|
||
|
||
|
||
sleY1731URControlDedicatedVlan OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates R-APS node to use dedicated-VLAN
|
||
disable : all VLAN
|
||
enable : one VLAN"
|
||
::= { sleY1731URControl 8 }
|
||
|
||
|
||
sleY1731URControlEnableStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Uplink-redundancy feature
|
||
0 : disable
|
||
1 : enable"
|
||
::= { sleY1731URControl 9 }
|
||
|
||
|
||
sleY1731URControlConnectivityCheckMeg OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the connectivity check - MEG name."
|
||
::= { sleY1731URControl 10 }
|
||
|
||
|
||
sleY1731URControlPrimaryMepId OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the connectivity check - primary MEP's ID"
|
||
::= { sleY1731URControl 11 }
|
||
|
||
|
||
sleY1731URControlSecondaryMepId OBJECT-TYPE
|
||
SYNTAX INTEGER (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the connectivity check - secondary MEP's ID"
|
||
::= { sleY1731URControl 12 }
|
||
|
||
|
||
sleY1731URControlControlVlan OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the control VLAN"
|
||
::= { sleY1731URControl 13 }
|
||
|
||
|
||
sleY1731URControlNodeConf OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
master(1),
|
||
slave(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the (master/slave) node of the redundancy"
|
||
::= { sleY1731URControl 14 }
|
||
|
||
|
||
sleY1731URControlNodeConfPortNum OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The port number"
|
||
::= { sleY1731URControl 15 }
|
||
|
||
|
||
sleY1731URControlNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
ture(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The non-revertive mode"
|
||
::= { sleY1731URControl 16 }
|
||
|
||
|
||
sleY1731URControlTrustMemberCount OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the trust LOC count at link-aggregation port"
|
||
::= { sleY1731URControl 17 }
|
||
|
||
|
||
sleY1731URControlWaitToRestore OBJECT-TYPE
|
||
SYNTAX INTEGER (5..720)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time ( 5 - 720 )"
|
||
::= { sleY1731URControl 18 }
|
||
|
||
|
||
sleY1731URControlForceSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The forced-switch of uplink port"
|
||
::= { sleY1731URControl 19 }
|
||
|
||
|
||
sleY1731URControlSFCondition OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
loc(0),
|
||
locRdi(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The sf condition"
|
||
::= { sleY1731URControl 20 }
|
||
|
||
|
||
sleY1731URControlTrafficVlan OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Traffic vlan"
|
||
::= { sleY1731URControl 21 }
|
||
|
||
|
||
sleY1731URControlManualSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The manual-switch of uplink port"
|
||
::= { sleY1731URControl 22 }
|
||
|
||
|
||
sleY1731URNotification OBJECT IDENTIFIER ::= { sleY1731UplinkRedundancy 3 }
|
||
|
||
|
||
sleY1731URDedicatedVlanChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlDedicatedVlan }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URDedicatedVlan"
|
||
::= { sleY1731URNotification 1 }
|
||
|
||
|
||
sleY1731UREnableStatusChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlEnableStatus }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731UREnableStatus"
|
||
::= { sleY1731URNotification 2 }
|
||
|
||
|
||
sleY1731URCCPrimaryMepIdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlConnectivityCheckMeg, sleY1731URControlPrimaryMepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URCCPrimaryMepId"
|
||
::= { sleY1731URNotification 3 }
|
||
|
||
|
||
sleY1731URCCPrimaryMepIdCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delY1731URCCPrimaryMepId"
|
||
::= { sleY1731URNotification 4 }
|
||
|
||
|
||
sleY1731URCCSecondaryMepIdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlConnectivityCheckMeg, sleY1731URControlSecondaryMepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URCCSecondaryMepId"
|
||
::= { sleY1731URNotification 5 }
|
||
|
||
|
||
sleY1731URCCSecondaryMepIdCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delY1731URCCSecondaryMepId"
|
||
::= { sleY1731URNotification 6 }
|
||
|
||
|
||
sleY1731URControlVlanChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlControlVlan }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URControlVlan"
|
||
::= { sleY1731URNotification 7 }
|
||
|
||
|
||
sleY1731URControlVlanCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delY1731URControlVlan"
|
||
::= { sleY1731URNotification 8 }
|
||
|
||
|
||
sleY1731URNodeConfChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlNodeConf, sleY1731URControlNodeConfPortNum }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URNodeConf"
|
||
::= { sleY1731URNotification 9 }
|
||
|
||
|
||
sleY1731URNodeConfCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlNodeConf }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delY1731URNodeConf"
|
||
::= { sleY1731URNotification 10 }
|
||
|
||
|
||
sleY1731URNonRevertiveChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlNonRevertive }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URNonRevertive"
|
||
::= { sleY1731URNotification 11 }
|
||
|
||
|
||
sleY1731URTrustMemberCountChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlTrustMemberCount }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URTrustMemberCount"
|
||
::= { sleY1731URNotification 12 }
|
||
|
||
|
||
sleY1731URTrustMemberCountCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delY1731URTrustMemberCount"
|
||
::= { sleY1731URNotification 13 }
|
||
|
||
|
||
sleY1731URWaitToRestoreChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlWaitToRestore }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setY1731URWaitToRestore"
|
||
::= { sleY1731URNotification 14 }
|
||
|
||
|
||
sleY1731URWaitToRestoreCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delY1731URWaitToRestore"
|
||
::= { sleY1731URNotification 15 }
|
||
|
||
|
||
sleY1731URForceSwitchChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlForceSwitch }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setForceSwitch"
|
||
::= { sleY1731URNotification 16 }
|
||
|
||
|
||
sleY1731URManualSwitchChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlManualSwitch }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setManualSwitch"
|
||
::= { sleY1731URNotification 17 }
|
||
|
||
|
||
sleY1731URSFConditionChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setSFCondition"
|
||
::= { sleY1731URNotification 18 }
|
||
|
||
|
||
sleY1731URTrafficVlanChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
|
||
sleY1731URControlTrafficVlan }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setTrafficVlan."
|
||
::= { sleY1731URNotification 19 }
|
||
|
||
|
||
sleY1731URTrafficVlanCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"clearTrafficVlan."
|
||
::= { sleY1731URNotification 20 }
|
||
|
||
|
||
sleY1731LocRefMep OBJECT IDENTIFIER ::= { sleY1731Oam 16 }
|
||
|
||
|
||
sleY1731LocRefMepTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleY1731LocRefMepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LocRefMep 1 }
|
||
|
||
|
||
sleY1731LocRefMepEntry OBJECT-TYPE
|
||
SYNTAX SleY1731LocRefMepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731CcMacAddress }
|
||
::= { sleY1731LocRefMepTable 1 }
|
||
|
||
|
||
SleY1731LocRefMepEntry ::=
|
||
SEQUENCE {
|
||
sleY1731LRMepIndex
|
||
Integer32,
|
||
sleY1731LRMepDMegIndex
|
||
Integer32,
|
||
sleY1731LRMepDMepIdentifier
|
||
Integer32,
|
||
sleY1731LRMepDRmepIdentifier
|
||
Integer32
|
||
}
|
||
|
||
sleY1731LRMepIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the index of the LOC reference MEP."
|
||
::= { sleY1731LocRefMepEntry 1 }
|
||
|
||
|
||
sleY1731LRMepDMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index of Down MEP"
|
||
::= { sleY1731LocRefMepEntry 2 }
|
||
|
||
|
||
sleY1731LRMepDMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the identifier of Down MEP."
|
||
::= { sleY1731LocRefMepEntry 3 }
|
||
|
||
|
||
sleY1731LRMepDRmepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the identifier of Remote MEP."
|
||
::= { sleY1731LocRefMepEntry 4 }
|
||
|
||
|
||
sleY1731LocRefMepControl OBJECT IDENTIFIER ::= { sleY1731LocRefMep 2 }
|
||
|
||
|
||
sleY1731LRMepControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createY1731LocRefMep(1),
|
||
deleteY1731LocRefMep(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LocRefMepControl 1 }
|
||
|
||
|
||
sleY1731LRMepControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LocRefMepControl 2 }
|
||
|
||
|
||
sleY1731LRMepControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LocRefMepControl 3 }
|
||
|
||
|
||
sleY1731LRMepControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleY1731LocRefMepControl 4 }
|
||
|
||
|
||
sleY1731LRMepControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result of the last command."
|
||
::= { sleY1731LocRefMepControl 5 }
|
||
|
||
|
||
sleY1731LRMepControlMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index of Up MEP."
|
||
::= { sleY1731LocRefMepControl 6 }
|
||
|
||
|
||
sleY1731LRMepControlMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the identifier of Up MEP."
|
||
::= { sleY1731LocRefMepControl 7 }
|
||
|
||
|
||
sleY1731LRMepControlRmepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the identifier of RMEP id of Up MEP."
|
||
::= { sleY1731LocRefMepControl 8 }
|
||
|
||
|
||
sleY1731LRMepControlDMegIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MEG's Index of Down MEP."
|
||
::= { sleY1731LocRefMepControl 9 }
|
||
|
||
|
||
sleY1731LRMepControlDMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the identifier of Down MEP."
|
||
::= { sleY1731LocRefMepControl 10 }
|
||
|
||
|
||
sleY1731LRMepControlDRmepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the identifier of RMEP id of Down MEP."
|
||
::= { sleY1731LocRefMepControl 11 }
|
||
|
||
|
||
sleY1731LocRefMepNotification OBJECT IDENTIFIER ::= { sleY1731LocRefMep 3 }
|
||
|
||
|
||
sleY1731LRMepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731LRMepControlRequest, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult, sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier,
|
||
sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier, sleY1731LRMepControlDRmepIdentifier }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createY1731LocRefMep"
|
||
::= { sleY1731LocRefMepNotification 1 }
|
||
|
||
|
||
sleY1731LRMEPDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleY1731LRMepControlRequest, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult, sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier,
|
||
sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier, sleY1731LRMepControlDRmepIdentifier }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteY1731LocRefMep"
|
||
::= { sleY1731LocRefMepNotification 3 }
|
||
|
||
|
||
sleCfmOam OBJECT IDENTIFIER ::= { sleFaultMgmt 13 }
|
||
|
||
|
||
sleCfmBase OBJECT IDENTIFIER ::= { sleCfmOam 1 }
|
||
|
||
|
||
sleCfmBaseGroup OBJECT IDENTIFIER ::= { sleCfmBase 1 }
|
||
|
||
|
||
sleCfmEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Ddisables IEEE 802.1ag CFM OAM function"
|
||
::= { sleCfmBaseGroup 1 }
|
||
|
||
|
||
sleCfmLtrCacheHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that cache entries will be retained"
|
||
::= { sleCfmBaseGroup 2 }
|
||
|
||
|
||
sleCfmLtrCacheSize OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of entries in the traceroute cache"
|
||
::= { sleCfmBaseGroup 3 }
|
||
|
||
|
||
sleCfmSnmpServerTraps OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
rdiccm(0),
|
||
macstatus(1),
|
||
remoteccm(2),
|
||
errorccm(3),
|
||
xconccm(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the SNMP traps"
|
||
::= { sleCfmBaseGroup 4 }
|
||
|
||
|
||
sleCfmXcheckStartDelay OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the delay before the cross-check is started"
|
||
::= { sleCfmBaseGroup 5 }
|
||
|
||
|
||
sleCfmBaseControl OBJECT IDENTIFIER ::= { sleCfmBase 2 }
|
||
|
||
|
||
sleCfmBaseControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setCfmEnable(1),
|
||
setCfmLtrCacheProfile(2),
|
||
setCfmSnmpProfile(3),
|
||
setCfmXcheckProfile(4),
|
||
destroyMipCcdb(5),
|
||
destroyLtrCache(6),
|
||
createCfmTrunkPort(7),
|
||
deleteCfmTrunkPort(8)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" This attribute identifies the control commands.
|
||
updateAlarmList:
|
||
the NE updates entries of alarms in the sleAlarmListTable
|
||
after having changed alarm severities of alarms
|
||
(due to change profile pointers in
|
||
managed entities or after modification of alarm severities
|
||
in profiles). This command should be applied once after having
|
||
finisled modifications of severties.
|
||
modifyAlarmSeverity:
|
||
modifies the severity of an alarm in specific profile.
|
||
createAlarmSeverityProfile:
|
||
creates a new profile with default severities.
|
||
The severities then have to be modified with command changeAlarmSeverity.
|
||
deleteAlarmSeverityProfile:
|
||
deletes a profile. Profile 1 is not allowed to be deleted.
|
||
|
||
Notifications : none "
|
||
::= { sleCfmBaseControl 1 }
|
||
|
||
|
||
sleCfmBaseControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleCfmBaseControl 2 }
|
||
|
||
|
||
sleCfmBaseControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleCfmBaseControl 3 }
|
||
|
||
|
||
sleCfmBaseControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleCfmBaseControl 4 }
|
||
|
||
|
||
sleCfmBaseControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleCfmBaseControl 5 }
|
||
|
||
|
||
sleCfmBaseControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Ddisables IEEE 802.1ag CFM OAM function"
|
||
::= { sleCfmBaseControl 6 }
|
||
|
||
|
||
sleCfmBaseControlLtrCacheHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that cache entries will be retained"
|
||
::= { sleCfmBaseControl 7 }
|
||
|
||
|
||
sleCfmBaseControlLtrCacheSize OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the number of entries in the traceroute cache"
|
||
::= { sleCfmBaseControl 8 }
|
||
|
||
|
||
sleCfmBaseControlSnmpServerTraps OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
ridccm(0),
|
||
macstatus(1),
|
||
remoteccm(2),
|
||
errorccm(3),
|
||
xconccm(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the SNMP traps"
|
||
::= { sleCfmBaseControl 9 }
|
||
|
||
|
||
sleCfmBaseControlXcheckStartDelay OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the delay before the cross-check is started"
|
||
::= { sleCfmBaseControl 10 }
|
||
|
||
|
||
sleCfmBaseControlTrunkIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Trunk Port Index"
|
||
::= { sleCfmBaseControl 11 }
|
||
|
||
|
||
sleCfmBaseControlTrunkMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"trunk port md name."
|
||
::= { sleCfmBaseControl 12 }
|
||
|
||
|
||
sleCfmBaseControlTrunkMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MA's VID"
|
||
::= { sleCfmBaseControl 13 }
|
||
|
||
|
||
sleCfmBaseNotification OBJECT IDENTIFIER ::= { sleCfmBase 3 }
|
||
|
||
|
||
sleCfmEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmEnable"
|
||
::= { sleCfmBaseNotification 1 }
|
||
|
||
|
||
sleCfmLtrCacheProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlLtrCacheHoldTime, sleCfmBaseControlLtrCacheSize
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmLtrCacheProfile"
|
||
::= { sleCfmBaseNotification 2 }
|
||
|
||
|
||
sleCfmSnmpServerTrapsChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlSnmpServerTraps }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmSnmpProfile"
|
||
::= { sleCfmBaseNotification 3 }
|
||
|
||
|
||
sleCfmXcheckStartDelayChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlXcheckStartDelay }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmXcheckProfile"
|
||
::= { sleCfmBaseNotification 4 }
|
||
|
||
|
||
sleCfmMipCcdbDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlRequest, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyMipCcdb"
|
||
::= { sleCfmBaseNotification 5 }
|
||
|
||
|
||
sleCfmLtrCacheDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlRequest, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyLtrCache"
|
||
::= { sleCfmBaseNotification 6 }
|
||
|
||
|
||
sleCfmTrunkPortCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlTrunkIndex, sleCfmBaseControlTrunkMdName,
|
||
sleCfmBaseControlTrunkMaVid }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createCfmTrunkPort"
|
||
::= { sleCfmBaseNotification 7 }
|
||
|
||
|
||
sleCfmTrunkPortDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlTrunkIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteCfmTrunkPort"
|
||
::= { sleCfmBaseNotification 8 }
|
||
|
||
|
||
sleCfmTrunkTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmTrunkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmBase 4 }
|
||
|
||
|
||
sleCfmTrunkEntry OBJECT-TYPE
|
||
SYNTAX SleCfmTrunkEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmTrunkIndex }
|
||
::= { sleCfmTrunkTable 1 }
|
||
|
||
|
||
SleCfmTrunkEntry ::=
|
||
SEQUENCE {
|
||
sleCfmTrunkIndex
|
||
INTEGER,
|
||
sleCfmTrunkMdName
|
||
OCTET STRING,
|
||
sleCfmTrunkMaVid
|
||
INTEGER
|
||
}
|
||
|
||
sleCfmTrunkIndex OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"trunk port index."
|
||
::= { sleCfmTrunkEntry 1 }
|
||
|
||
|
||
sleCfmTrunkMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"trunk port md name."
|
||
::= { sleCfmTrunkEntry 2 }
|
||
|
||
|
||
sleCfmTrunkMaVid OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MA's VID"
|
||
::= { sleCfmTrunkEntry 3 }
|
||
|
||
|
||
sleCfmMd OBJECT IDENTIFIER ::= { sleCfmOam 2 }
|
||
|
||
|
||
sleCfmMdTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmMdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMd 1 }
|
||
|
||
|
||
sleCfmMdEntry OBJECT-TYPE
|
||
SYNTAX SleCfmMdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMdIndex }
|
||
::= { sleCfmMdTable 1 }
|
||
|
||
|
||
SleCfmMdEntry ::=
|
||
SEQUENCE {
|
||
sleCfmMdIndex
|
||
Integer32,
|
||
sleCfmMdName
|
||
OCTET STRING,
|
||
sleCfmMdLevel
|
||
Integer32,
|
||
sleCfmMdMepEnable
|
||
INTEGER,
|
||
sleCfmMdCcEnable
|
||
INTEGER,
|
||
sleCfmMdCcInterval
|
||
Integer32,
|
||
sleCfmMdCcPriority
|
||
Integer32,
|
||
sleCfmMdCcLossThreshold
|
||
Integer32,
|
||
sleCfmMdCcHoldTime
|
||
Integer32,
|
||
sleCfmMdFaultPriority
|
||
INTEGER,
|
||
sleCfmMdFaultKeepTime
|
||
Integer32,
|
||
sleCfmMdFaultClearTime
|
||
Integer32,
|
||
sleCfmMdXcheckEnable
|
||
INTEGER
|
||
}
|
||
|
||
sleCfmMdIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MD's Index"
|
||
::= { sleCfmMdEntry 1 }
|
||
|
||
|
||
sleCfmMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MD's name"
|
||
::= { sleCfmMdEntry 2 }
|
||
|
||
|
||
sleCfmMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MD's level"
|
||
::= { sleCfmMdEntry 3 }
|
||
|
||
|
||
sleCfmMdMepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM OAM for MEPs"
|
||
::= { sleCfmMdEntry 4 }
|
||
|
||
|
||
sleCfmMdCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables MEPs to send Continuity Check messages"
|
||
::= { sleCfmMdEntry 5 }
|
||
|
||
|
||
sleCfmMdCcInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between CCM transmissions"
|
||
::= { sleCfmMdEntry 6 }
|
||
|
||
|
||
sleCfmMdCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM Priority"
|
||
::= { sleCfmMdEntry 7 }
|
||
|
||
|
||
sleCfmMdCcLossThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (2..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
|
||
::= { sleCfmMdEntry 8 }
|
||
|
||
|
||
sleCfmMdCcHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that data of a missing MEP is kept"
|
||
::= { sleCfmMdEntry 9 }
|
||
|
||
|
||
sleCfmMdFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdiccm(1),
|
||
macstatus(2),
|
||
remoteccm(3),
|
||
errorccm(4),
|
||
xconccm(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the lowest priority for fault alarm"
|
||
::= { sleCfmMdEntry 10 }
|
||
|
||
|
||
sleCfmMdFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the keep time for the fault alarm"
|
||
::= { sleCfmMdEntry 11 }
|
||
|
||
|
||
sleCfmMdFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the clear time for the fault alarm"
|
||
::= { sleCfmMdEntry 12 }
|
||
|
||
|
||
sleCfmMdXcheckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM cross-check for a specific MEG"
|
||
::= { sleCfmMdEntry 13 }
|
||
|
||
|
||
sleCfmMdControl OBJECT IDENTIFIER ::= { sleCfmMd 2 }
|
||
|
||
|
||
sleCfmMdControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmMd(1),
|
||
deleteCfmMd(2),
|
||
setCfmMdMepEnable(3),
|
||
setCfmMdCcEnable(4),
|
||
setCfmMdCcProfile(5),
|
||
setCfmMdFaultProfile(6),
|
||
setCfmMdXcheckEnable(7),
|
||
destroyCfmMdError(8),
|
||
destroyCfmMdRmep(9)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMdControl 1 }
|
||
|
||
|
||
sleCfmMdControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMdControl 2 }
|
||
|
||
|
||
sleCfmMdControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMdControl 3 }
|
||
|
||
|
||
sleCfmMdControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMdControl 4 }
|
||
|
||
|
||
sleCfmMdControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMdControl 5 }
|
||
|
||
|
||
sleCfmMdControlIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MD's Index"
|
||
::= { sleCfmMdControl 6 }
|
||
|
||
|
||
sleCfmMdControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MD's name"
|
||
::= { sleCfmMdControl 7 }
|
||
|
||
|
||
sleCfmMdControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MD's level"
|
||
::= { sleCfmMdControl 8 }
|
||
|
||
|
||
sleCfmMdControlMepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM OAM for MEPs"
|
||
::= { sleCfmMdControl 9 }
|
||
|
||
|
||
sleCfmMdControlCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables MEPs to send Continuity Check messages"
|
||
::= { sleCfmMdControl 10 }
|
||
|
||
|
||
sleCfmMdControlCcInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between CCM transmissions"
|
||
::= { sleCfmMdControl 11 }
|
||
|
||
|
||
sleCfmMdControlCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM Priority"
|
||
::= { sleCfmMdControl 12 }
|
||
|
||
|
||
sleCfmMdControlCcLossThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (2..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
|
||
::= { sleCfmMdControl 13 }
|
||
|
||
|
||
sleCfmMdControlCcHoldTime OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the time that data of a missing MEP is kept"
|
||
::= { sleCfmMdControl 14 }
|
||
|
||
|
||
sleCfmMdControlFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdiccm(1),
|
||
macstatus(2),
|
||
remoteccm(3),
|
||
errorccm(4),
|
||
xconccm(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the lowest priority for fault alarm"
|
||
::= { sleCfmMdControl 15 }
|
||
|
||
|
||
sleCfmMdControlFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the keep time for the fault alarm"
|
||
::= { sleCfmMdControl 16 }
|
||
|
||
|
||
sleCfmMdControlFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the clear time for the fault alarm"
|
||
::= { sleCfmMdControl 17 }
|
||
|
||
|
||
sleCfmMdControlXcheckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM cross-check for a specific MEG"
|
||
::= { sleCfmMdControl 18 }
|
||
|
||
|
||
sleCfmMdNotification OBJECT IDENTIFIER ::= { sleCfmMd 3 }
|
||
|
||
|
||
sleCfmMdCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlName, sleCfmMdControlLevel
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createCfmMd"
|
||
::= { sleCfmMdNotification 1 }
|
||
|
||
|
||
sleCfmMdDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteCfmMd"
|
||
::= { sleCfmMdNotification 2 }
|
||
|
||
|
||
sleCfmMdMepEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlMepEnable
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMepEnable"
|
||
::= { sleCfmMdNotification 3 }
|
||
|
||
|
||
sleCfmMdCcEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlCcEnable
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMdCcEnable"
|
||
::= { sleCfmMdNotification 4 }
|
||
|
||
|
||
sleCfmMdCcProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlCcInterval,
|
||
sleCfmMdControlCcPriority, sleCfmMdControlCcLossThreshold, sleCfmMdControlCcHoldTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMdCcProfile"
|
||
::= { sleCfmMdNotification 5 }
|
||
|
||
|
||
sleCfmMdFaultProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlFaultPriority,
|
||
sleCfmMdControlFaultKeepTime, sleCfmMdControlFaultClearTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMdFaultProfile"
|
||
::= { sleCfmMdNotification 6 }
|
||
|
||
|
||
sleCfmMdXcheckEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlXcheckEnable
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMdXcheckEnable"
|
||
::= { sleCfmMdNotification 7 }
|
||
|
||
|
||
sleCfmMdErrorDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyCfmMdError"
|
||
::= { sleCfmMdNotification 8 }
|
||
|
||
|
||
sleCfmMdRmepDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyCfmMdRmep"
|
||
::= { sleCfmMdNotification 9 }
|
||
|
||
|
||
sleCfmMa OBJECT IDENTIFIER ::= { sleCfmOam 3 }
|
||
|
||
|
||
sleCfmMaTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmMaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMa 1 }
|
||
|
||
|
||
sleCfmMaEntry OBJECT-TYPE
|
||
SYNTAX SleCfmMaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMdIndex, sleCfmMaIndex }
|
||
::= { sleCfmMaTable 1 }
|
||
|
||
|
||
SleCfmMaEntry ::=
|
||
SEQUENCE {
|
||
sleCfmMaIndex
|
||
Integer32,
|
||
sleCfmMaName
|
||
OCTET STRING,
|
||
sleCfmMaVid
|
||
Integer32,
|
||
sleCfmMaMepEnable
|
||
INTEGER,
|
||
sleCfmMaCcEnable
|
||
INTEGER,
|
||
sleCfmMaCcInterval
|
||
Integer32,
|
||
sleCfmMaCcPriority
|
||
Integer32,
|
||
sleCfmMaCcLossThreshold
|
||
Integer32,
|
||
sleCfmMaCcFaultPriority
|
||
INTEGER,
|
||
sleCfmMaCcFaultKeepTime
|
||
Integer32,
|
||
sleCfmMaCcFaultClearTime
|
||
Integer32,
|
||
sleCfmMaXcheckEnable
|
||
INTEGER
|
||
}
|
||
|
||
sleCfmMaIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MA's Index"
|
||
::= { sleCfmMaEntry 1 }
|
||
|
||
|
||
sleCfmMaName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MA's name"
|
||
::= { sleCfmMaEntry 2 }
|
||
|
||
|
||
sleCfmMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MA's VID"
|
||
::= { sleCfmMaEntry 3 }
|
||
|
||
|
||
sleCfmMaMepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM OAM for MEPs"
|
||
::= { sleCfmMaEntry 4 }
|
||
|
||
|
||
sleCfmMaCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables MEPs to send Continuity Check messages"
|
||
::= { sleCfmMaEntry 5 }
|
||
|
||
|
||
sleCfmMaCcInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between CCM transmissions"
|
||
::= { sleCfmMaEntry 6 }
|
||
|
||
|
||
sleCfmMaCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM Priority"
|
||
::= { sleCfmMaEntry 7 }
|
||
|
||
|
||
sleCfmMaCcLossThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (2..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
|
||
::= { sleCfmMaEntry 8 }
|
||
|
||
|
||
sleCfmMaCcFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdiccm(1),
|
||
macstatus(2),
|
||
remoteccm(3),
|
||
errorccm(4),
|
||
xconccm(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the lowest priority for fault alarm"
|
||
::= { sleCfmMaEntry 9 }
|
||
|
||
|
||
sleCfmMaCcFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the keep time for the fault alarm"
|
||
::= { sleCfmMaEntry 10 }
|
||
|
||
|
||
sleCfmMaCcFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the clear time for the fault alarm"
|
||
::= { sleCfmMaEntry 11 }
|
||
|
||
|
||
sleCfmMaXcheckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM cross-check for a specific MEG"
|
||
::= { sleCfmMaEntry 12 }
|
||
|
||
|
||
sleCfmMaControl OBJECT IDENTIFIER ::= { sleCfmMa 2 }
|
||
|
||
|
||
sleCfmMaControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmMa(1),
|
||
deleteCfmMa(2),
|
||
setCfmMaMepEnable(3),
|
||
setCfmMaCcEnable(4),
|
||
setCfmMaCcProfile(5),
|
||
setCfmMaFaultProfile(6),
|
||
setCfmMaXcheckEnable(7)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMaControl 1 }
|
||
|
||
|
||
sleCfmMaControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMaControl 2 }
|
||
|
||
|
||
sleCfmMaControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMaControl 3 }
|
||
|
||
|
||
sleCfmMaControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMaControl 4 }
|
||
|
||
|
||
sleCfmMaControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMaControl 5 }
|
||
|
||
|
||
sleCfmMaControlIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MA's Index"
|
||
::= { sleCfmMaControl 6 }
|
||
|
||
|
||
sleCfmMaControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..12))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MA's name."
|
||
::= { sleCfmMaControl 7 }
|
||
|
||
|
||
sleCfmMaControlVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MA's VID"
|
||
::= { sleCfmMaControl 8 }
|
||
|
||
|
||
sleCfmMaControlMdIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MD's Index"
|
||
::= { sleCfmMaControl 9 }
|
||
|
||
|
||
sleCfmMaControlMepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM OAM for MEPs"
|
||
::= { sleCfmMaControl 10 }
|
||
|
||
|
||
sleCfmMaControlCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables MEPs to send Continuity Check messages"
|
||
::= { sleCfmMaControl 11 }
|
||
|
||
|
||
sleCfmMaControlCcInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval between CCM transmissions"
|
||
::= { sleCfmMaControl 12 }
|
||
|
||
|
||
sleCfmMaControlCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM Priority"
|
||
::= { sleCfmMaControl 13 }
|
||
|
||
|
||
sleCfmMaControlCcLossThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (2..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
|
||
::= { sleCfmMaControl 14 }
|
||
|
||
|
||
sleCfmMaControlFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdiccm(1),
|
||
macstatus(2),
|
||
remoteccm(3),
|
||
errorccm(4),
|
||
xconccm(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the lowest priority for fault alarm"
|
||
::= { sleCfmMaControl 15 }
|
||
|
||
|
||
sleCfmMaControlFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the keep time for the fault alarm"
|
||
::= { sleCfmMaControl 16 }
|
||
|
||
|
||
sleCfmMaControlFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the clear time for the fault alarm"
|
||
::= { sleCfmMaControl 17 }
|
||
|
||
|
||
sleCfmMaControlXcheckEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables CFM cross-check for a specific MEG"
|
||
::= { sleCfmMaControl 18 }
|
||
|
||
|
||
sleCfmMaNotification OBJECT IDENTIFIER ::= { sleCfmMa 3 }
|
||
|
||
|
||
sleCfmMaCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlName, sleCfmMaControlMdIndex,
|
||
sleCfmMaControlVid }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createCfmMa"
|
||
::= { sleCfmMaNotification 1 }
|
||
|
||
|
||
sleCfmMaDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlName, sleCfmMaControlMdIndex
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteCfmMa"
|
||
::= { sleCfmMaNotification 2 }
|
||
|
||
|
||
sleCfmMaMepEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
|
||
sleCfmMaControlMepEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMaMepEnable"
|
||
::= { sleCfmMaNotification 3 }
|
||
|
||
|
||
sleCfmMaCcEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
|
||
sleCfmMaControlCcEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMaCcEnable"
|
||
::= { sleCfmMaNotification 4 }
|
||
|
||
|
||
sleCfmMaCcProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
|
||
sleCfmMaControlCcInterval, sleCfmMaControlCcPriority, sleCfmMaControlCcLossThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMaCcProfile"
|
||
::= { sleCfmMaNotification 5 }
|
||
|
||
|
||
sleCfmMaFaultProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
|
||
sleCfmMaControlFaultPriority, sleCfmMaControlFaultKeepTime, sleCfmMaControlFaultClearTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMaFaultProfile"
|
||
::= { sleCfmMaNotification 6 }
|
||
|
||
|
||
sleCfmMaXcheckEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
|
||
sleCfmMaControlXcheckEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMaXcheckEnable"
|
||
::= { sleCfmMaNotification 7 }
|
||
|
||
|
||
sleCfmMep OBJECT IDENTIFIER ::= { sleCfmOam 4 }
|
||
|
||
|
||
sleCfmMepTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmMepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMep 1 }
|
||
|
||
|
||
sleCfmMepEntry OBJECT-TYPE
|
||
SYNTAX SleCfmMepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIfIndex }
|
||
::= { sleCfmMepTable 1 }
|
||
|
||
|
||
SleCfmMepEntry ::=
|
||
SEQUENCE {
|
||
sleCfmMepIdentifier
|
||
Integer32,
|
||
sleCfmMepIfIndex
|
||
Integer32,
|
||
sleCfmMepDirection
|
||
INTEGER,
|
||
sleCfmMepEnable
|
||
INTEGER,
|
||
sleCfmMepFngState
|
||
INTEGER,
|
||
sleCfmMepCcEnable
|
||
INTEGER,
|
||
sleCfmMepMacAddress
|
||
OCTET STRING,
|
||
sleCfmMepCcPriority
|
||
Integer32,
|
||
sleCfmMepFaultPriority
|
||
INTEGER,
|
||
sleCfmMepFaultKeepTime
|
||
Integer32,
|
||
sleCfmMepFaultClearTime
|
||
Integer32,
|
||
sleCfmMepHighestPrDefect
|
||
INTEGER,
|
||
sleCfmMepDefects
|
||
BITS,
|
||
sleCfmMepCciSentCcms
|
||
Counter32,
|
||
sleCfmMepNextLbmTransId
|
||
Integer32,
|
||
sleCfmMepLbrIn
|
||
Counter32,
|
||
sleCfmMepLbrInOutOfOrder
|
||
Counter32,
|
||
sleCfmMepLtmNextSeqNumber
|
||
Integer32,
|
||
sleCfmMepUnexpLtrIn
|
||
Counter32
|
||
}
|
||
|
||
sleCfmMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MEP Id"
|
||
::= { sleCfmMepEntry 1 }
|
||
|
||
|
||
sleCfmMepIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Brige Port Index whitch the MEP is attached"
|
||
::= { sleCfmMepEntry 2 }
|
||
|
||
|
||
sleCfmMepDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
down(0),
|
||
up(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The direction in which the MEP faces on the Bridge port"
|
||
::= { sleCfmMepEntry 3 }
|
||
|
||
|
||
sleCfmMepEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Administrative state of the MEP"
|
||
::= { sleCfmMepEntry 4 }
|
||
|
||
|
||
sleCfmMepFngState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
reset(1),
|
||
defect(2),
|
||
reportDefect(3),
|
||
defectReported(4),
|
||
defectCearing(5),
|
||
defectCleared(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current state of the MEP Fault Notification Generator State Machine"
|
||
::= { sleCfmMepEntry 5 }
|
||
|
||
|
||
sleCfmMepCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP will generate CCM messages"
|
||
::= { sleCfmMepEntry 6 }
|
||
|
||
|
||
sleCfmMepMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MAC address of the MEP"
|
||
::= { sleCfmMepEntry 7 }
|
||
|
||
|
||
sleCfmMepCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM Priority"
|
||
::= { sleCfmMepEntry 8 }
|
||
|
||
|
||
sleCfmMepFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdiccm(1),
|
||
macstatus(2),
|
||
remoteccm(3),
|
||
errorccm(4),
|
||
xconccm(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
|
||
::= { sleCfmMepEntry 9 }
|
||
|
||
|
||
sleCfmMepFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be present before a Fault Alarm is issued"
|
||
::= { sleCfmMepEntry 10 }
|
||
|
||
|
||
sleCfmMepFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be absent before resetting a Fault Alarm"
|
||
::= { sleCfmMepEntry 11 }
|
||
|
||
|
||
sleCfmMepHighestPrDefect OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdiccm(1),
|
||
macstatus(2),
|
||
remoteccm(3),
|
||
errorccm(4),
|
||
xconccm(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine was last in the FNG_RESET state"
|
||
::= { sleCfmMepEntry 12 }
|
||
|
||
|
||
sleCfmMepDefects OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
rdiccm(0),
|
||
macstatus(1),
|
||
remoteccm(2),
|
||
errorccm(3),
|
||
xconccm(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A vector of Boolean defect conditions"
|
||
::= { sleCfmMepEntry 13 }
|
||
|
||
|
||
sleCfmMepCciSentCcms OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total number of Continuity Check messages transmitted"
|
||
::= { sleCfmMepEntry 14 }
|
||
|
||
|
||
sleCfmMepNextLbmTransId OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Next sequence number/transaction identifier to be sent in a Loopback message"
|
||
::= { sleCfmMepEntry 15 }
|
||
|
||
|
||
sleCfmMepLbrIn OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total number of valid, in-order Loopback Replies received"
|
||
::= { sleCfmMepEntry 16 }
|
||
|
||
|
||
sleCfmMepLbrInOutOfOrder OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of valid, out-of-order Loopback Replies received"
|
||
::= { sleCfmMepEntry 17 }
|
||
|
||
|
||
sleCfmMepLtmNextSeqNumber OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Next transaction identifier/sequence number to be sent in a Linktrace message."
|
||
::= { sleCfmMepEntry 18 }
|
||
|
||
|
||
sleCfmMepUnexpLtrIn OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The total number of unexpected LTRs received"
|
||
::= { sleCfmMepEntry 19 }
|
||
|
||
|
||
sleCfmMepControl OBJECT IDENTIFIER ::= { sleCfmMep 2 }
|
||
|
||
|
||
sleCfmMepControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmMep(1),
|
||
deleteCfmMep(2),
|
||
setCfmMepEnable(3),
|
||
setCfmMepCcEnable(4),
|
||
setCfmMepCcProfile(5),
|
||
setCfmMepFaultProfile(6),
|
||
transmitCfmLbm(7),
|
||
transmitCfmLtm(8)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMepControl 1 }
|
||
|
||
|
||
sleCfmMepControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMepControl 2 }
|
||
|
||
|
||
sleCfmMepControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMepControl 3 }
|
||
|
||
|
||
sleCfmMepControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMepControl 4 }
|
||
|
||
|
||
sleCfmMepControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMepControl 5 }
|
||
|
||
|
||
sleCfmMepControlIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"MEP Id"
|
||
::= { sleCfmMepControl 6 }
|
||
|
||
|
||
sleCfmMepControlMdIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A index of MD table"
|
||
::= { sleCfmMepControl 7 }
|
||
|
||
|
||
sleCfmMepControlMaIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MA's Index"
|
||
::= { sleCfmMepControl 8 }
|
||
|
||
|
||
sleCfmMepControlIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Bridge Port Index whitch the MEP is attached"
|
||
::= { sleCfmMepControl 9 }
|
||
|
||
|
||
sleCfmMepControlDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
down(0),
|
||
up(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The direction in which the MEP faces on the Bridge port"
|
||
::= { sleCfmMepControl 10 }
|
||
|
||
|
||
sleCfmMepControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Administrative state of the MEP"
|
||
::= { sleCfmMepControl 11 }
|
||
|
||
|
||
sleCfmMepControlCcEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If set to true, the MEP will generate CCM messages"
|
||
::= { sleCfmMepControl 12 }
|
||
|
||
|
||
sleCfmMepControlCcPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the CCM Priority"
|
||
::= { sleCfmMepControl 13 }
|
||
|
||
|
||
sleCfmMepControlFaultPriority OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rdiccm(1),
|
||
macstatus(2),
|
||
remoteccm(3),
|
||
errorccm(4),
|
||
xconccm(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
|
||
::= { sleCfmMepControl 14 }
|
||
|
||
|
||
sleCfmMepControlFaultKeepTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be present before a Fault Alarm is issued"
|
||
::= { sleCfmMepControl 15 }
|
||
|
||
|
||
sleCfmMepControlFaultClearTime OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time that defects must be absent before resetting a Fault Alarm"
|
||
::= { sleCfmMepControl 16 }
|
||
|
||
|
||
sleCfmMepControlTransmitLbmDestMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Target MAC Address Field to be transmitted"
|
||
::= { sleCfmMepControl 17 }
|
||
|
||
|
||
sleCfmMepControlTransmitLbmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
|
||
::= { sleCfmMepControl 18 }
|
||
|
||
|
||
sleCfmMepControlTransmitLbmDestIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"True indicates that MEPID of the target MEP is used for Loopback transmission"
|
||
::= { sleCfmMepControl 19 }
|
||
|
||
|
||
sleCfmMepControlTransmitLbmCount OBJECT-TYPE
|
||
SYNTAX Integer32 (1..6000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The number of Loopback messages to be transmitted"
|
||
::= { sleCfmMepControl 20 }
|
||
|
||
|
||
sleCfmMepControlTransmitLbmInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interval for sending LBM"
|
||
::= { sleCfmMepControl 21 }
|
||
|
||
|
||
sleCfmMepControlTransmitLbmTimeout OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the waiting time for receiving the expected LBR"
|
||
::= { sleCfmMepControl 22 }
|
||
|
||
|
||
sleCfmMepControlTransmitLbmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Priority. 3 bit value to be used in the VLAN tag"
|
||
::= { sleCfmMepControl 23 }
|
||
|
||
|
||
sleCfmMepControlTransmitLtmTargetMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Target MAC Address Field to be transmitted: A unicast destination MAC address."
|
||
::= { sleCfmMepControl 24 }
|
||
|
||
|
||
sleCfmMepControlTransmitLtmTargetMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An indication of the Target MAC Address Field to be transmitted"
|
||
::= { sleCfmMepControl 25 }
|
||
|
||
|
||
sleCfmMepControlTransmitLtmTargetIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"True indicates that MEPID of the target MEP is used for Linktrace transmission."
|
||
::= { sleCfmMepControl 26 }
|
||
|
||
|
||
sleCfmMepControlTransmitLtmFlags OBJECT-TYPE
|
||
SYNTAX BITS { useFDBonly(0) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The flags field for LTMs transmitted by the MEP"
|
||
::= { sleCfmMepControl 27 }
|
||
|
||
|
||
sleCfmMepControlTransmitLtmTtl OBJECT-TYPE
|
||
SYNTAX Integer32 (1..64)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The LTM TTL field"
|
||
::= { sleCfmMepControl 28 }
|
||
|
||
|
||
sleCfmMepNotification OBJECT IDENTIFIER ::= { sleCfmMep 3 }
|
||
|
||
|
||
sleCfmMepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
|
||
sleCfmMepControlMaIndex, sleCfmMepControlIfIndex, sleCfmMepControlDirection }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createCfmMep"
|
||
::= { sleCfmMepNotification 1 }
|
||
|
||
|
||
sleCfmMepDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
|
||
sleCfmMepControlMaIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteCfmMep"
|
||
::= { sleCfmMepNotification 2 }
|
||
|
||
|
||
sleCfmMepEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
|
||
sleCfmMepControlMaIndex, sleCfmMepControlEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMepEnable"
|
||
::= { sleCfmMepNotification 3 }
|
||
|
||
|
||
sleCfmMepCcEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
|
||
sleCfmMepControlMaIndex, sleCfmMepControlCcEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMepCcEnable"
|
||
::= { sleCfmMepNotification 4 }
|
||
|
||
|
||
sleCfmMepCcProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
|
||
sleCfmMepControlMaIndex, sleCfmMdControlCcPriority }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMepCcProfile"
|
||
::= { sleCfmMepNotification 5 }
|
||
|
||
|
||
sleCfmMepFaultProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
|
||
sleCfmMepControlMaIndex, sleCfmMepControlFaultPriority, sleCfmMepControlFaultKeepTime, sleCfmMepControlFaultClearTime }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setCfmMepFaultProfile"
|
||
::= { sleCfmMepNotification 6 }
|
||
|
||
|
||
sleCfmMip OBJECT IDENTIFIER ::= { sleCfmOam 5 }
|
||
|
||
|
||
sleCfmMipTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmMipEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMip 1 }
|
||
|
||
|
||
sleCfmMipEntry OBJECT-TYPE
|
||
SYNTAX SleCfmMipEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMipPort }
|
||
::= { sleCfmMipTable 1 }
|
||
|
||
|
||
SleCfmMipEntry ::=
|
||
SEQUENCE {
|
||
sleCfmMipPort
|
||
Integer32,
|
||
sleCfmMipLevel
|
||
Integer32,
|
||
sleCfmMipType
|
||
INTEGER
|
||
}
|
||
|
||
sleCfmMipPort OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port number"
|
||
::= { sleCfmMipEntry 1 }
|
||
|
||
|
||
sleCfmMipLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MIP's level"
|
||
::= { sleCfmMipEntry 2 }
|
||
|
||
|
||
sleCfmMipType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
static(1),
|
||
dynamic(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate the MIP<49><50>s type"
|
||
::= { sleCfmMipEntry 3 }
|
||
|
||
|
||
sleCfmMipControl OBJECT IDENTIFIER ::= { sleCfmMip 2 }
|
||
|
||
|
||
sleCfmMipControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmMip(1),
|
||
deleteCfmMip(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMipControl 1 }
|
||
|
||
|
||
sleCfmMipControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMipControl 2 }
|
||
|
||
|
||
sleCfmMipControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMipControl 3 }
|
||
|
||
|
||
sleCfmMipControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMipControl 4 }
|
||
|
||
|
||
sleCfmMipControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMipControl 5 }
|
||
|
||
|
||
sleCfmMipControlPort OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port number"
|
||
::= { sleCfmMipControl 6 }
|
||
|
||
|
||
sleCfmMipControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MIP's level"
|
||
::= { sleCfmMipControl 7 }
|
||
|
||
|
||
sleCfmMipNotification OBJECT IDENTIFIER ::= { sleCfmMip 3 }
|
||
|
||
|
||
sleCfmMipCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMipControlRequest, sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort, sleCfmMipControlLevel
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createCfmMip"
|
||
::= { sleCfmMipNotification 1 }
|
||
|
||
|
||
sleCfmMipDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmMipControlRequest, sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteCfmMip"
|
||
::= { sleCfmMipNotification 2 }
|
||
|
||
|
||
sleCfmXcheck OBJECT IDENTIFIER ::= { sleCfmOam 6 }
|
||
|
||
|
||
sleCfmXcheckTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmXcheckEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmXcheck 1 }
|
||
|
||
|
||
sleCfmXcheckEntry OBJECT-TYPE
|
||
SYNTAX SleCfmXcheckEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmXcheckMepIdentifier }
|
||
::= { sleCfmXcheckTable 1 }
|
||
|
||
|
||
SleCfmXcheckEntry ::=
|
||
SEQUENCE {
|
||
sleCfmXcheckMepIdentifier
|
||
Integer32,
|
||
sleCfmXcheckMepState
|
||
INTEGER
|
||
}
|
||
|
||
sleCfmXcheckMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the remote MEP's Id"
|
||
::= { sleCfmXcheckEntry 1 }
|
||
|
||
|
||
sleCfmXcheckMepState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(0),
|
||
missing(1),
|
||
up(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the cross-check MEP<45><50>s state"
|
||
::= { sleCfmXcheckEntry 2 }
|
||
|
||
|
||
sleCfmXcheckControl OBJECT IDENTIFIER ::= { sleCfmXcheck 2 }
|
||
|
||
|
||
sleCfmXcheckControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmXcheckMep(1),
|
||
deleteCfmXcheckMep(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmXcheckControl 1 }
|
||
|
||
|
||
sleCfmXcheckControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmXcheckControl 2 }
|
||
|
||
|
||
sleCfmXcheckControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmXcheckControl 3 }
|
||
|
||
|
||
sleCfmXcheckControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmXcheckControl 4 }
|
||
|
||
|
||
sleCfmXcheckControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmXcheckControl 5 }
|
||
|
||
|
||
sleCfmXcheckControlMepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the remote MEP's Id"
|
||
::= { sleCfmXcheckControl 6 }
|
||
|
||
|
||
sleCfmXcheckControlMdIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MD<4D><44>s Index"
|
||
::= { sleCfmXcheckControl 7 }
|
||
|
||
|
||
sleCfmXcheckControlMaIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MA's Index"
|
||
::= { sleCfmXcheckControl 8 }
|
||
|
||
|
||
sleCfmXcheckNotification OBJECT IDENTIFIER ::= { sleCfmXcheck 3 }
|
||
|
||
|
||
sleCfmXcheckMepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmXcheckControlRequest, sleCfmXcheckControlTimeStamp, sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex,
|
||
sleCfmXcheckControlMaIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createCfmXcheckMep"
|
||
::= { sleCfmXcheckNotification 1 }
|
||
|
||
|
||
sleCfmXcheckMepDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleCfmXcheckControlRequest, sleCfmXcheckControlTimeStamp, sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex,
|
||
sleCfmXcheckControlMaIndex }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteCfmXcheckMep"
|
||
::= { sleCfmXcheckNotification 2 }
|
||
|
||
|
||
sleCfmRmep OBJECT IDENTIFIER ::= { sleCfmOam 7 }
|
||
|
||
|
||
sleCfmRmepTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmRmepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmRmep 1 }
|
||
|
||
|
||
sleCfmRmepEntry OBJECT-TYPE
|
||
SYNTAX SleCfmRmepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIdentifier, sleCfmRmepIdentifier }
|
||
::= { sleCfmRmepTable 1 }
|
||
|
||
|
||
SleCfmRmepEntry ::=
|
||
SEQUENCE {
|
||
sleCfmRmepIdentifier
|
||
Integer32,
|
||
sleCfmRmepState
|
||
INTEGER,
|
||
sleCfmRmepMacAddress
|
||
OCTET STRING,
|
||
sleCfmRmepIfIndex
|
||
Integer32,
|
||
sleCfmRmepRdi
|
||
INTEGER,
|
||
sleCfmRmepPortStatus
|
||
INTEGER,
|
||
sleCfmRmepInterfaceStatus
|
||
INTEGER
|
||
}
|
||
|
||
sleCfmRmepIdentifier OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the remote MEP's Id"
|
||
::= { sleCfmRmepEntry 1 }
|
||
|
||
|
||
sleCfmRmepState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
idle(1),
|
||
start(2),
|
||
failed(3),
|
||
ok(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the operational state of the remote MEP State machines"
|
||
::= { sleCfmRmepEntry 2 }
|
||
|
||
|
||
sleCfmRmepMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MAC address of the remote MEP"
|
||
::= { sleCfmRmepEntry 3 }
|
||
|
||
|
||
sleCfmRmepIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port number of the remote MEP"
|
||
::= { sleCfmRmepEntry 4 }
|
||
|
||
|
||
sleCfmRmepRdi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received"
|
||
::= { sleCfmRmepEntry 5 }
|
||
|
||
|
||
sleCfmRmepPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
up(2),
|
||
down(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Port status of the remote MEP"
|
||
::= { sleCfmRmepEntry 6 }
|
||
|
||
|
||
sleCfmRmepInterfaceStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
up(2),
|
||
down(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the interface status of the remote MEP"
|
||
::= { sleCfmRmepEntry 7 }
|
||
|
||
|
||
sleCfmLtr OBJECT IDENTIFIER ::= { sleCfmOam 8 }
|
||
|
||
|
||
sleCfmLtrTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmLtrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmLtr 1 }
|
||
|
||
|
||
sleCfmLtrEntry OBJECT-TYPE
|
||
SYNTAX SleCfmLtrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIdentifier, sleCfmLtrSeqNumber, sleCfmLtrReceiveOrder
|
||
}
|
||
::= { sleCfmLtrTable 1 }
|
||
|
||
|
||
SleCfmLtrEntry ::=
|
||
SEQUENCE {
|
||
sleCfmLtrSeqNumber
|
||
Integer32,
|
||
sleCfmLtrReceiveOrder
|
||
Integer32,
|
||
sleCfmLtrTtl
|
||
Integer32,
|
||
sleCfmLtrForwarded
|
||
INTEGER,
|
||
sleCfmLtrTerminalMep
|
||
INTEGER,
|
||
sleCfmLtrLastEgressIdentifier
|
||
OCTET STRING,
|
||
sleCfmLtrNextEgressIdentifier
|
||
OCTET STRING,
|
||
sleCfmLtrRelay
|
||
INTEGER,
|
||
sleCfmLtrIngress
|
||
INTEGER,
|
||
sleCfmLtrIngressMac
|
||
OCTET STRING,
|
||
sleCfmLtrIngressPort
|
||
Integer32,
|
||
sleCfmLtrEgress
|
||
INTEGER,
|
||
sleCfmLtrEgressMac
|
||
OCTET STRING,
|
||
sleCfmLtrEgressPort
|
||
Integer32
|
||
}
|
||
|
||
sleCfmLtrSeqNumber OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the LTM Transaction Identifier returned from a previous Transmit Linktrace Message command,
|
||
indicating the LTM entry to which the LTR entries will be attached
|
||
"
|
||
::= { sleCfmLtrEntry 1 }
|
||
|
||
|
||
sleCfmLtrReceiveOrder OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates an index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value"
|
||
::= { sleCfmLtrEntry 2 }
|
||
|
||
|
||
sleCfmLtrTtl OBJECT-TYPE
|
||
SYNTAX Integer32 (1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates TTL field value for a returned LTR."
|
||
::= { sleCfmLtrEntry 3 }
|
||
|
||
|
||
sleCfmLtrForwarded OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field."
|
||
::= { sleCfmLtrEntry 4 }
|
||
|
||
|
||
sleCfmLtrTerminalMep OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates a boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field. "
|
||
::= { sleCfmLtrEntry 5 }
|
||
|
||
|
||
sleCfmLtrLastEgressIdentifier OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies the MEP Linktrace Initiator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response"
|
||
::= { sleCfmLtrEntry 6 }
|
||
|
||
|
||
sleCfmLtrNextEgressIdentifier OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (8))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop."
|
||
::= { sleCfmLtrEntry 7 }
|
||
|
||
|
||
sleCfmLtrRelay OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rlyHit(1),
|
||
rlyFDB(2),
|
||
rlyMPDB(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the value returned in the Ingress Action Field of the LTM"
|
||
::= { sleCfmLtrEntry 8 }
|
||
|
||
|
||
sleCfmLtrIngress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ingNoTlv(0),
|
||
ingOK(1),
|
||
ingDown(2),
|
||
ingBlocked(3),
|
||
ingVid(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the value returned in the Ingress Action Field of the LTM"
|
||
::= { sleCfmLtrEntry 9 }
|
||
|
||
|
||
sleCfmLtrIngressMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates MAC address returned in the ingress MAC address field."
|
||
::= { sleCfmLtrEntry 10 }
|
||
|
||
|
||
sleCfmLtrIngressPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates Ingress Port ID"
|
||
::= { sleCfmLtrEntry 11 }
|
||
|
||
|
||
sleCfmLtrEgress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
egrNoTlv(0),
|
||
egrOK(1),
|
||
egrDown(2),
|
||
egrBlocked(3),
|
||
egrVid(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the value returned in the Egress Action Field of the LTM"
|
||
::= { sleCfmLtrEntry 12 }
|
||
|
||
|
||
sleCfmLtrEgressMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates MAC address returned in the egress MAC address field."
|
||
::= { sleCfmLtrEntry 13 }
|
||
|
||
|
||
sleCfmLtrEgressPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates Egress Port ID"
|
||
::= { sleCfmLtrEntry 14 }
|
||
|
||
|
||
sleCfmConfigError OBJECT IDENTIFIER ::= { sleCfmOam 9 }
|
||
|
||
|
||
sleCfmConfigErrorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmConfigErrorEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmConfigError 1 }
|
||
|
||
|
||
sleCfmConfigErrorEntry OBJECT-TYPE
|
||
SYNTAX SleCfmConfigErrorEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmConfigErrorVid, sleCfmConfigErrorIfIndex }
|
||
::= { sleCfmConfigErrorTable 1 }
|
||
|
||
|
||
SleCfmConfigErrorEntry ::=
|
||
SEQUENCE {
|
||
sleCfmConfigErrorVid
|
||
Integer32,
|
||
sleCfmConfigErrorIfIndex
|
||
Integer32,
|
||
sleCfmConfigErrorType
|
||
BITS
|
||
}
|
||
|
||
sleCfmConfigErrorVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Configuration Error VLAN Identifier"
|
||
::= { sleCfmConfigErrorEntry 1 }
|
||
|
||
|
||
sleCfmConfigErrorIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Configuration Error Port Number"
|
||
::= { sleCfmConfigErrorEntry 2 }
|
||
|
||
|
||
sleCfmConfigErrorType OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
cfmleak(0),
|
||
conflictingVids(1),
|
||
excessiveLevels(2),
|
||
overlappedLevels(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Configuration Error Type"
|
||
::= { sleCfmConfigErrorEntry 3 }
|
||
|
||
|
||
sleCfmMipCcdb OBJECT IDENTIFIER ::= { sleCfmOam 10 }
|
||
|
||
|
||
sleCfmMipCcdbTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleCfmMipCcdbEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleCfmMipCcdb 1 }
|
||
|
||
|
||
sleCfmMipCcdbEntry OBJECT-TYPE
|
||
SYNTAX SleCfmMipCcdbEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleCfmMipCcdbIndex }
|
||
::= { sleCfmMipCcdbTable 1 }
|
||
|
||
|
||
SleCfmMipCcdbEntry ::=
|
||
SEQUENCE {
|
||
sleCfmMipCcdbIndex
|
||
Integer32,
|
||
sleCfmMipCcdbVlanId
|
||
Integer32,
|
||
sleCfmMipCcdbMacAddr
|
||
OCTET STRING,
|
||
sleCfmMipCcdbPort
|
||
Integer32,
|
||
sleCfmMipCcdbKeepTime
|
||
OCTET STRING
|
||
}
|
||
|
||
sleCfmMipCcdbIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the MIP CCDB's Index"
|
||
::= { sleCfmMipCcdbEntry 1 }
|
||
|
||
|
||
sleCfmMipCcdbVlanId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"VLAN Id"
|
||
::= { sleCfmMipCcdbEntry 2 }
|
||
|
||
|
||
sleCfmMipCcdbMacAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates MAC address of the remote MEP"
|
||
::= { sleCfmMipCcdbEntry 3 }
|
||
|
||
|
||
sleCfmMipCcdbPort OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Port number that the CCM output"
|
||
::= { sleCfmMipCcdbEntry 4 }
|
||
|
||
|
||
sleCfmMipCcdbKeepTime OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (1..20))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates an up-date time of a entry"
|
||
::= { sleCfmMipCcdbEntry 5 }
|
||
|
||
|
||
sleEMLog OBJECT IDENTIFIER ::= { sleFaultMgmt 14 }
|
||
|
||
|
||
sleEMLogInfo OBJECT IDENTIFIER ::= { sleEMLog 1 }
|
||
|
||
|
||
sleEMLogDisableStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"EM log disable."
|
||
::= { sleEMLogInfo 1 }
|
||
|
||
|
||
sleEMLogAction OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
syslog(0),
|
||
trap(1),
|
||
recover(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Generate syslog message or SNMP Trap or take a recover action
|
||
"
|
||
::= { sleEMLogInfo 2 }
|
||
|
||
|
||
sleEMLogInterval OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1440)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Action interval in minute (Default. 3 mins)"
|
||
::= { sleEMLogInfo 3 }
|
||
|
||
|
||
sleEMLogNAKLockStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of emlog nak-locking"
|
||
::= { sleEMLogInfo 4 }
|
||
|
||
|
||
sleEMLogNakCompensate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of emlog nak-compensate (shadow recovery)"
|
||
::= { sleEMLogInfo 5 }
|
||
|
||
|
||
sleEMLogRecoverActionMemLow OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
switchover(1),
|
||
none(255)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate recover action of memory low"
|
||
::= { sleEMLogInfo 6 }
|
||
|
||
|
||
sleEMLogRecoverActionNak OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
switchover(1),
|
||
none(255)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate recover action of NAK error"
|
||
::= { sleEMLogInfo 7 }
|
||
|
||
|
||
sleEMLogControl OBJECT IDENTIFIER ::= { sleEMLog 2 }
|
||
|
||
|
||
sleEMLogControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setDisableStatus(1),
|
||
setAction(2),
|
||
setInterval(3),
|
||
setNAKLock(4),
|
||
setNAKCompensate(5),
|
||
setRecoverActionMemLow(6),
|
||
setRecoverActionNAK(7)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" This attribute identifies the control commands.
|
||
updateAlarmList:
|
||
the NE updates entries of alarms in the sleAlarmListTable
|
||
after having changed alarm severities of alarms
|
||
(due to change profile pointers in
|
||
managed entities or after modification of alarm severities
|
||
in profiles). This command should be applied once after having
|
||
finisled modifications of severties.
|
||
modifyAlarmSeverity:
|
||
modifies the severity of an alarm in specific profile.
|
||
createAlarmSeverityProfile:
|
||
creates a new profile with default severities.
|
||
The severities then have to be modified with command changeAlarmSeverity.
|
||
deleteAlarmSeverityProfile:
|
||
deletes a profile. Profile 1 is not allowed to be deleted.
|
||
|
||
Notifications : none "
|
||
::= { sleEMLogControl 1 }
|
||
|
||
|
||
sleEMLogControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleEMLogControl 2 }
|
||
|
||
|
||
sleEMLogControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleEMLogControl 3 }
|
||
|
||
|
||
sleEMLogControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleEMLogControl 4 }
|
||
|
||
|
||
sleEMLogControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleEMLogControl 5 }
|
||
|
||
|
||
sleEMLogControlDisableStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"EM log disable."
|
||
::= { sleEMLogControl 6 }
|
||
|
||
|
||
sleEMLogControlAction OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
syslog(0),
|
||
trap(1),
|
||
recover(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Generate syslog message or SNMP trap."
|
||
::= { sleEMLogControl 7 }
|
||
|
||
|
||
sleEMLogControlInterval OBJECT-TYPE
|
||
SYNTAX INTEGER (1..1440)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Action interval in minute (Default. 3 mins)"
|
||
::= { sleEMLogControl 8 }
|
||
|
||
|
||
sleEMLogControlNAKLockStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of emlog nak-locking"
|
||
::= { sleEMLogControl 9 }
|
||
|
||
|
||
sleEMLogControlNAKCompensate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of emlog nak-compensate (shadow recovery)"
|
||
::= { sleEMLogControl 10 }
|
||
|
||
|
||
sleEMLogControlRecoverActionMemLow OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
switchover(1),
|
||
none(255)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate recover action of memory low"
|
||
::= { sleEMLogControl 11 }
|
||
|
||
|
||
sleEMLogControlRecoverActionNAK OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
switchover(1),
|
||
none(255)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate recover action of NAK error
|
||
"
|
||
::= { sleEMLogControl 12 }
|
||
|
||
|
||
sleEMLogNotification OBJECT IDENTIFIER ::= { sleEMLog 3 }
|
||
|
||
|
||
sleEMLogDisableStatusChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlDisableStatus }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEMLogNotification 1 }
|
||
|
||
|
||
sleEMLogActionChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlAction }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEMLogNotification 2 }
|
||
|
||
|
||
sleEMLogIntervalChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlInterval }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEMLogNotification 3 }
|
||
|
||
|
||
sleEMLogNAKLockChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlNAKLockStatus }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEMLogNotification 4 }
|
||
|
||
|
||
sleEMLogNAKCompensateChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlNAKCompensate }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEMLogNotification 5 }
|
||
|
||
|
||
sleEMLogRecoverActionMemLowChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlRecoverActionMemLow }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEMLogNotification 6 }
|
||
|
||
|
||
sleEMLogRecoverActionNAKChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlRecoverActionNAK }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleEMLogNotification 7 }
|
||
|
||
|
||
sleEMLogDefectInfo OBJECT IDENTIFIER ::= { sleEMLog 4 }
|
||
|
||
|
||
sleEMLogDefectCPUHigh OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The CPU high defection information."
|
||
::= { sleEMLogDefectInfo 1 }
|
||
|
||
|
||
sleEMLogTemperHigh OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The temperature hish defection information."
|
||
::= { sleEMLogDefectInfo 2 }
|
||
|
||
|
||
sleEMLogTemperLow OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The temperature low defection information."
|
||
::= { sleEMLogDefectInfo 3 }
|
||
|
||
|
||
sleEMLogMemLow OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The memory low defection information."
|
||
::= { sleEMLogDefectInfo 4 }
|
||
|
||
|
||
sleEMLogFanFail OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The fan failure defection information."
|
||
::= { sleEMLogDefectInfo 5 }
|
||
|
||
|
||
sleEMLogPhyCRCFail OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The PHY CRC failure defection information."
|
||
::= { sleEMLogDefectInfo 6 }
|
||
|
||
|
||
sleEMLogPhyDetectFail OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The PHY detection failure defection information."
|
||
::= { sleEMLogDefectInfo 7 }
|
||
|
||
|
||
sleEMLogSFUMateInitFail OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SFU mate init failure defection information"
|
||
::= { sleEMLogDefectInfo 8 }
|
||
|
||
|
||
sleEMLogDaemonHealthBad OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The daemon health bad defection information."
|
||
::= { sleEMLogDefectInfo 9 }
|
||
|
||
|
||
sleEMLogGPIURavenLinkDown OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The GPIU raven link down defection information."
|
||
::= { sleEMLogDefectInfo 10 }
|
||
|
||
|
||
sleEMLogFANRPMLow OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The FAN RPM Low defection information."
|
||
::= { sleEMLogDefectInfo 11 }
|
||
|
||
|
||
sleEMLogNAK OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
slot1(0),
|
||
slot2(1),
|
||
slot3(2),
|
||
slot4(3),
|
||
slot5(4),
|
||
slot6(5),
|
||
slot7(6),
|
||
slot8(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The NAK Error defection information."
|
||
::= { sleEMLogDefectInfo 12 }
|
||
|
||
|
||
sleRapsRing OBJECT IDENTIFIER ::= { sleFaultMgmt 15 }
|
||
|
||
|
||
sleRapsRingTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleRapsRingEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleRapsRing 1 }
|
||
|
||
|
||
sleRapsRingEntry OBJECT-TYPE
|
||
SYNTAX SleRapsRingEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleRapsRingId }
|
||
::= { sleRapsRingTable 1 }
|
||
|
||
|
||
SleRapsRingEntry ::=
|
||
SEQUENCE {
|
||
sleRapsRingId
|
||
Integer32,
|
||
sleRapsRingType
|
||
INTEGER,
|
||
sleRapsRingLevel
|
||
INTEGER,
|
||
sleRapsRingCtrlVlan
|
||
INTEGER,
|
||
sleRapsRingTrafficVlans
|
||
OCTET STRING,
|
||
sleRapsRingVirtualVlan
|
||
INTEGER,
|
||
sleRapsRingNodeId
|
||
OCTET STRING,
|
||
sleRapsRingEnable
|
||
INTEGER,
|
||
sleRapsRingBridgeRole
|
||
INTEGER,
|
||
sleRapsRingState
|
||
INTEGER,
|
||
sleRapsRingEastPort
|
||
Integer32,
|
||
sleRapsRingEastPortStatus
|
||
INTEGER,
|
||
sleRapsRingWestPort
|
||
Integer32,
|
||
sleRapsRingWestPortStatus
|
||
INTEGER,
|
||
sleRapsRingRplPort
|
||
INTEGER,
|
||
sleRapsRingIcPort
|
||
INTEGER,
|
||
sleRapsRingIcNode
|
||
INTEGER,
|
||
sleRapsRingMultipleFailure
|
||
INTEGER,
|
||
sleRapsRingPropagateTc
|
||
INTEGER,
|
||
sleRapsRingNonRevertive
|
||
INTEGER,
|
||
sleRapsRingForcedSwitch
|
||
INTEGER,
|
||
sleRapsRingManualSwitch
|
||
INTEGER,
|
||
sleRapsRingHoldOffTime
|
||
INTEGER,
|
||
sleRapsRingGuardTime
|
||
INTEGER,
|
||
sleRapsRingWaitToRestore
|
||
INTEGER,
|
||
sleRapsRingWaitToBlock
|
||
INTEGER,
|
||
sleRapsRingInstId
|
||
Integer32,
|
||
sleRapsRingChannel
|
||
INTEGER,
|
||
sleRapsRingPassThrough
|
||
INTEGER,
|
||
sleRapsRingVerifiedTime
|
||
INTEGER
|
||
}
|
||
|
||
sleRapsRingId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s ID"
|
||
::= { sleRapsRingEntry 1 }
|
||
|
||
|
||
sleRapsRingType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
major(1),
|
||
sub(2),
|
||
access(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s type"
|
||
::= { sleRapsRingEntry 2 }
|
||
|
||
|
||
sleRapsRingLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s level"
|
||
::= { sleRapsRingEntry 3 }
|
||
|
||
|
||
sleRapsRingCtrlVlan OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s control-vlan"
|
||
::= { sleRapsRingEntry 4 }
|
||
|
||
|
||
sleRapsRingTrafficVlans OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s traffic-vlans"
|
||
::= { sleRapsRingEntry 5 }
|
||
|
||
|
||
sleRapsRingVirtualVlan OBJECT-TYPE
|
||
SYNTAX INTEGER (0..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node's virtual-vlan"
|
||
::= { sleRapsRingEntry 6 }
|
||
|
||
|
||
sleRapsRingNodeId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s ID"
|
||
::= { sleRapsRingEntry 7 }
|
||
|
||
|
||
sleRapsRingEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/Disables Ring Node"
|
||
::= { sleRapsRingEntry 8 }
|
||
|
||
|
||
sleRapsRingBridgeRole OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
normal(0),
|
||
rplowner(1),
|
||
rplneighbour(2),
|
||
rplnextneighbour(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s Role"
|
||
::= { sleRapsRingEntry 9 }
|
||
|
||
|
||
sleRapsRingState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
idle(1),
|
||
protection(2),
|
||
manual(3),
|
||
forced(4),
|
||
pending(5),
|
||
required(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s State"
|
||
::= { sleRapsRingEntry 10 }
|
||
|
||
|
||
sleRapsRingEastPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s east port"
|
||
::= { sleRapsRingEntry 11 }
|
||
|
||
|
||
sleRapsRingEastPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
disabled(1),
|
||
forwarding(2),
|
||
blocking(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port status of east port"
|
||
::= { sleRapsRingEntry 12 }
|
||
|
||
|
||
sleRapsRingWestPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s west port"
|
||
::= { sleRapsRingEntry 13 }
|
||
|
||
|
||
sleRapsRingWestPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
disabled(1),
|
||
forwarding(2),
|
||
blocking(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the port status of west port"
|
||
::= { sleRapsRingEntry 14 }
|
||
|
||
|
||
sleRapsRingRplPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s RPL port"
|
||
::= { sleRapsRingEntry 15 }
|
||
|
||
|
||
sleRapsRingIcPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s interconnection port"
|
||
::= { sleRapsRingEntry 16 }
|
||
|
||
|
||
sleRapsRingIcNode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
primary(1),
|
||
secondary(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the primary/secondary node for the minimization of the segmentation"
|
||
::= { sleRapsRingEntry 17 }
|
||
|
||
|
||
sleRapsRingMultipleFailure OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
primary(1),
|
||
secondary(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The multiple failure mode"
|
||
::= { sleRapsRingEntry 18 }
|
||
|
||
|
||
sleRapsRingPropagateTc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The propagation TC(topology change)"
|
||
::= { sleRapsRingEntry 19 }
|
||
|
||
|
||
sleRapsRingNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Non-Revertive"
|
||
::= { sleRapsRingEntry 20 }
|
||
|
||
|
||
sleRapsRingForcedSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
east(1),
|
||
west(2),
|
||
both(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Forced Switch"
|
||
::= { sleRapsRingEntry 21 }
|
||
|
||
|
||
sleRapsRingManualSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Manual Switch"
|
||
::= { sleRapsRingEntry 22 }
|
||
|
||
|
||
sleRapsRingHoldOffTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the hold-off time"
|
||
::= { sleRapsRingEntry 23 }
|
||
|
||
|
||
sleRapsRingGuardTime OBJECT-TYPE
|
||
SYNTAX INTEGER (10..2000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the guard time"
|
||
::= { sleRapsRingEntry 24 }
|
||
|
||
|
||
sleRapsRingWaitToRestore OBJECT-TYPE
|
||
SYNTAX INTEGER (1..12)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time"
|
||
::= { sleRapsRingEntry 25 }
|
||
|
||
|
||
sleRapsRingWaitToBlock OBJECT-TYPE
|
||
SYNTAX INTEGER (5..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-block time"
|
||
::= { sleRapsRingEntry 26 }
|
||
|
||
|
||
sleRapsRingInstId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the ring instance ID."
|
||
::= { sleRapsRingEntry 27 }
|
||
|
||
|
||
sleRapsRingChannel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
virtual(1),
|
||
abstract(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the R-APS channel type."
|
||
::= { sleRapsRingEntry 28 }
|
||
|
||
|
||
sleRapsRingPassThrough OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the pass-through funtion."
|
||
::= { sleRapsRingEntry 29 }
|
||
|
||
|
||
sleRapsRingVerifiedTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the verified time"
|
||
::= { sleRapsRingEntry 30 }
|
||
|
||
|
||
sleRapsRingControl OBJECT IDENTIFIER ::= { sleRapsRing 2 }
|
||
|
||
|
||
sleRapsRingControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createRapsRing(1),
|
||
deleteRapsRing(2),
|
||
setRapsRingChannel(3),
|
||
setRapsRingEnable(4),
|
||
setRapsRingPorts(5),
|
||
destroyRapsRingPorts(6),
|
||
setRapsRingRplPort(7),
|
||
setRapsRingIcPort(8),
|
||
destroyRapsRingIcPort(9),
|
||
setRapsRingMultipleFailure(10),
|
||
setRapsRingPropagateTc(11),
|
||
setRapsRingNonRevertive(12),
|
||
setRapsRingForcedSwitch(13),
|
||
setRapsRingManualSwitch(14),
|
||
setRapsRingClearSwitch(15),
|
||
setRapsRingHoldOffTime(16),
|
||
setRapsRingGuardTime(17),
|
||
setRapsRingWtrTime(18),
|
||
setRapsRingWtbTime(19),
|
||
setRapsRingPassThrough(20),
|
||
setRapsRingVrfTime(21)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleRapsRingControl 1 }
|
||
|
||
|
||
sleRapsRingControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleRapsRingControl 2 }
|
||
|
||
|
||
sleRapsRingControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleRapsRingControl 3 }
|
||
|
||
|
||
sleRapsRingControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleRapsRingControl 4 }
|
||
|
||
|
||
sleRapsRingControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleRapsRingControl 5 }
|
||
|
||
|
||
sleRapsRingControlId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s ID"
|
||
::= { sleRapsRingControl 6 }
|
||
|
||
|
||
sleRapsRingControlType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
major(1),
|
||
sub(2),
|
||
access(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s type"
|
||
::= { sleRapsRingControl 7 }
|
||
|
||
|
||
sleRapsRingControlLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s level"
|
||
::= { sleRapsRingControl 8 }
|
||
|
||
|
||
sleRapsRingControlCtrlVlan OBJECT-TYPE
|
||
SYNTAX INTEGER (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s control-vlan"
|
||
::= { sleRapsRingControl 9 }
|
||
|
||
|
||
sleRapsRingControlTrafficVlans OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s traffic-vlans"
|
||
::= { sleRapsRingControl 10 }
|
||
|
||
|
||
sleRapsRingControlChannel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
virtual(1),
|
||
abstract(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node's channel"
|
||
::= { sleRapsRingControl 11 }
|
||
|
||
|
||
sleRapsRingControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IEnables/Disables Ring Node"
|
||
::= { sleRapsRingControl 12 }
|
||
|
||
|
||
sleRapsRingControlEastPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s east port"
|
||
::= { sleRapsRingControl 13 }
|
||
|
||
|
||
sleRapsRingControlWestPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64><65>s west port"
|
||
::= { sleRapsRingControl 14 }
|
||
|
||
|
||
sleRapsRingControlParamPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the rpl port, interconnection port, forced or manual switch port."
|
||
::= { sleRapsRingControl 15 }
|
||
|
||
|
||
sleRapsRingControlBridgeRole OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
rplowner(1),
|
||
neighbour(2),
|
||
nextneighbour(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E><67>s RPL port type"
|
||
::= { sleRapsRingControl 16 }
|
||
|
||
|
||
sleRapsRingControlIcNode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
primary(1),
|
||
secondary(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the primary/secondary node for the minimization of the segmentation"
|
||
::= { sleRapsRingControl 17 }
|
||
|
||
|
||
sleRapsRingControlMultipleFailure OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
primary(1),
|
||
secondary(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The multiple failure of Ring Node"
|
||
::= { sleRapsRingControl 18 }
|
||
|
||
|
||
sleRapsRingControlPropagateTc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The propagation TC"
|
||
::= { sleRapsRingControl 19 }
|
||
|
||
|
||
sleRapsRingControlNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Non-Revertive"
|
||
::= { sleRapsRingControl 20 }
|
||
|
||
|
||
sleRapsRingControlHoldOffTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the hold-off time.
|
||
The hold-off time's step must be 100
|
||
"
|
||
::= { sleRapsRingControl 21 }
|
||
|
||
|
||
sleRapsRingControlGuardTime OBJECT-TYPE
|
||
SYNTAX INTEGER (10..2000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the guard time.
|
||
The guard time's step must be 10.
|
||
"
|
||
::= { sleRapsRingControl 22 }
|
||
|
||
|
||
sleRapsRingControlWaitToRestore OBJECT-TYPE
|
||
SYNTAX INTEGER (1..12)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time
|
||
"
|
||
::= { sleRapsRingControl 23 }
|
||
|
||
|
||
sleRapsRingControlWaitToBlock OBJECT-TYPE
|
||
SYNTAX INTEGER (5..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-block time"
|
||
::= { sleRapsRingControl 24 }
|
||
|
||
|
||
sleRapsRingControlInstId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the ring instance ID."
|
||
::= { sleRapsRingControl 25 }
|
||
|
||
|
||
sleRapsRingControlPassThrough OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the pass-through function."
|
||
::= { sleRapsRingControl 26 }
|
||
|
||
|
||
sleRapsRingControlVerifiedTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the verified time."
|
||
::= { sleRapsRingControl 27 }
|
||
|
||
|
||
sleRapsRingNotification OBJECT IDENTIFIER ::= { sleRapsRing 3 }
|
||
|
||
|
||
sleRapsRingCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlId,
|
||
sleRapsRingControlType, sleRapsRingControlLevel, sleRapsRingControlCtrlVlan, sleRapsRingControlTrafficVlans }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createRapsRing"
|
||
::= { sleRapsRingNotification 1 }
|
||
|
||
|
||
sleRapsRingDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"deleteRapsRing"
|
||
::= { sleRapsRingNotification 2 }
|
||
|
||
|
||
sleRapsRingChannelChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlChannel
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingChannel"
|
||
::= { sleRapsRingNotification 3 }
|
||
|
||
|
||
sleRapsRingEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlEnable
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingEnable"
|
||
::= { sleRapsRingNotification 4 }
|
||
|
||
|
||
sleRapsRingPortsCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlEastPort,
|
||
sleRapsRingControlWestPort, sleRapsRingControlParamPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingPorts"
|
||
::= { sleRapsRingNotification 5 }
|
||
|
||
|
||
sleRapsRingPortsDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyRapsRingPorts"
|
||
::= { sleRapsRingNotification 6 }
|
||
|
||
|
||
sleRapsRingRplPortChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlBridgeRole,
|
||
sleRapsRingControlParamPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingRplPort"
|
||
::= { sleRapsRingNotification 7 }
|
||
|
||
|
||
sleRapsRingIcPortCreated NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlIcNode, sleRapsRingControlParamPort,
|
||
sleRapsRingControlInstId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingIcPort"
|
||
::= { sleRapsRingNotification 8 }
|
||
|
||
|
||
sleRapsRingIcPortDestroyed NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destroyRapsRingIcPort"
|
||
::= { sleRapsRingNotification 9 }
|
||
|
||
|
||
sleRapsRingMultipleFailureChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlMultipleFailure
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingMultipleFailure"
|
||
::= { sleRapsRingNotification 10 }
|
||
|
||
|
||
sleRapsRingPropagateTcChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlPropagateTc
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingPropagateTc"
|
||
::= { sleRapsRingNotification 11 }
|
||
|
||
|
||
sleRapsRingNonRevertiveChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlNonRevertive
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingNonRevertive"
|
||
::= { sleRapsRingNotification 12 }
|
||
|
||
|
||
sleRapsRingForcedSwitchChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlParamPort
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingForcedSwitch"
|
||
::= { sleRapsRingNotification 13 }
|
||
|
||
|
||
sleRapsRingManualSwitchChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlParamPort
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingManualSwitch"
|
||
::= { sleRapsRingNotification 14 }
|
||
|
||
|
||
sleRapsRingSwitchCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingClearSwitch"
|
||
::= { sleRapsRingNotification 15 }
|
||
|
||
|
||
sleRapsRingHoldOffTimeChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlHoldOffTime
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingHoldOffTime"
|
||
::= { sleRapsRingNotification 16 }
|
||
|
||
|
||
sleRapsRingGuardTimeChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlGuardTime
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingGuardTime"
|
||
::= { sleRapsRingNotification 17 }
|
||
|
||
|
||
sleRapsRingWtrTimeChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlWaitToRestore
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingWtrTime"
|
||
::= { sleRapsRingNotification 18 }
|
||
|
||
|
||
sleRapsRingWtbTimeChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlWaitToBlock
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingWtbTime"
|
||
::= { sleRapsRingNotification 19 }
|
||
|
||
|
||
sleRapsRingPassThroughChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlPassThrough
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingPassThrough"
|
||
::= { sleRapsRingNotification 20 }
|
||
|
||
|
||
sleRapsRingVrfTimeChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlVerifiedTime
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setRapsRingVrfTime"
|
||
::= { sleRapsRingNotification 21 }
|
||
|
||
|
||
sleFaultMonitor OBJECT IDENTIFIER ::= { sleFaultMgmt 16 }
|
||
|
||
|
||
sleFaultMonitorGlobal OBJECT IDENTIFIER ::= { sleFaultMonitor 1 }
|
||
|
||
|
||
sleFaultMonitorGlobalBase OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 1 }
|
||
|
||
|
||
sleFaultMonitorGlobalInspectInterval OBJECT-TYPE
|
||
SYNTAX INTEGER (3..86400)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"daemon Inspection value.
|
||
unit : sec, default : 5
|
||
"
|
||
::= { sleFaultMonitorGlobalBase 1 }
|
||
|
||
|
||
sleFaultMonitorGlobalStartupThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (100..1000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"daemon startup threshold value.
|
||
unit : sec, default : 100
|
||
|
||
"
|
||
::= { sleFaultMonitorGlobalBase 2 }
|
||
|
||
|
||
sleFaultMonitorGlobalNoKeepalive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
resetMate(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate action when don't receive keepalive msg.
|
||
"
|
||
::= { sleFaultMonitorGlobalBase 3 }
|
||
|
||
|
||
sleFaultMonitorGlobalControl OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 2 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setGlobalInspectInterval(1),
|
||
setGlobalStartupThreshold(2),
|
||
setNoKeepaliveAction(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleFaultMonitorGlobalControl 1 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleFaultMonitorGlobalControl 2 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlTimer OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleFaultMonitorGlobalControl 3 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleFaultMonitorGlobalControl 4 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleFaultMonitorGlobalControl 5 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlInspectInterval OBJECT-TYPE
|
||
SYNTAX INTEGER (3..86400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"daemon Inspection value.
|
||
unit : sec, default : 5
|
||
"
|
||
::= { sleFaultMonitorGlobalControl 6 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlStartupThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (100..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"daemon startup threshold value.
|
||
unit : sec, default : 100
|
||
"
|
||
::= { sleFaultMonitorGlobalControl 7 }
|
||
|
||
|
||
sleFaultMonitorGlobalControlNoKeepalive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
switchover(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate action when don't receive keepalive msg.
|
||
"
|
||
::= { sleFaultMonitorGlobalControl 8 }
|
||
|
||
|
||
sleFaultMonitorGlobalNotification OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 3 }
|
||
|
||
|
||
setFaultMonitorGlobalInspectIntervalChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlInspectInterval }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorGlobalNotification 1 }
|
||
|
||
|
||
setFaultMonitorGlobalStartupThresholdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlStartupThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorGlobalNotification 2 }
|
||
|
||
|
||
setFaultMonitorGlobalNoKeepaliveActionChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlNoKeepalive }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorGlobalNotification 3 }
|
||
|
||
|
||
sleFaultMonitorDaemonConfig OBJECT IDENTIFIER ::= { sleFaultMonitor 2 }
|
||
|
||
|
||
sleFaultMonitorDaemonTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleFaultMonitorDaemonEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonConfig 1 }
|
||
|
||
|
||
sleFaultMonitorDaemonEntry OBJECT-TYPE
|
||
SYNTAX SleFaultMonitorDaemonEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleFaultMonitorDaemonPid }
|
||
::= { sleFaultMonitorDaemonTable 1 }
|
||
|
||
|
||
SleFaultMonitorDaemonEntry ::=
|
||
SEQUENCE {
|
||
sleFaultMonitorDaemonName
|
||
OCTET STRING,
|
||
sleFaultMonitorDaemonPid
|
||
Integer32,
|
||
sleFaultMonitorDaemonAdminStatus
|
||
INTEGER,
|
||
sleFaultMonitorDaemonCrashAction
|
||
INTEGER,
|
||
sleFaultMonitorDaemonTimeoutAction
|
||
INTEGER,
|
||
sleFaultMonitorDaemonThreshold
|
||
Integer32,
|
||
sleFaultMonitorDaemonThresholded
|
||
Integer32,
|
||
sleFaultMonitorDaemonStartupThresholded
|
||
Integer32,
|
||
sleFaultMonitorDaemonWatchdogAdminStatus
|
||
INTEGER,
|
||
sleFaultMonitorDaemonWatchdogThreshold
|
||
Integer32,
|
||
sleFaultMonitorDaemonWatchdogCount
|
||
Integer32
|
||
}
|
||
|
||
sleFaultMonitorDaemonName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Daemon name"
|
||
::= { sleFaultMonitorDaemonEntry 1 }
|
||
|
||
|
||
sleFaultMonitorDaemonPid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Daemon PID
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 2 }
|
||
|
||
|
||
sleFaultMonitorDaemonAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Daemon Inspection admin status.
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 3 }
|
||
|
||
|
||
sleFaultMonitorDaemonCrashAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
restart(2),
|
||
switchover(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate action type when daemon is crashed
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 4 }
|
||
|
||
|
||
sleFaultMonitorDaemonTimeoutAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
restart(2),
|
||
switchover(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate action type when daemon is timeout
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 5 }
|
||
|
||
|
||
sleFaultMonitorDaemonThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate fault admin threshold.
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 6 }
|
||
|
||
|
||
sleFaultMonitorDaemonThresholded OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate fault accumulated threshold.
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 7 }
|
||
|
||
|
||
sleFaultMonitorDaemonStartupThresholded OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonEntry 8 }
|
||
|
||
|
||
sleFaultMonitorDaemonWatchdogAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate whether connect watchdog or not
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 9 }
|
||
|
||
|
||
sleFaultMonitorDaemonWatchdogThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (5..60)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate watchdog threshold of daemon.
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 10 }
|
||
|
||
|
||
sleFaultMonitorDaemonWatchdogCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate watchdog accumulated count.
|
||
"
|
||
::= { sleFaultMonitorDaemonEntry 11 }
|
||
|
||
|
||
sleFaultMonitorDaemonControl OBJECT IDENTIFIER ::= { sleFaultMonitorDaemonConfig 2 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setDaemonAdminStatus(1),
|
||
setDaemonFaultAction(2),
|
||
setDaemonThreshold(3),
|
||
setDaemonWatchdog(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleFaultMonitorDaemonControl 1 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleFaultMonitorDaemonControl 2 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlTimer OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleFaultMonitorDaemonControl 3 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleFaultMonitorDaemonControl 4 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleFaultMonitorDaemonControl 5 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonControl 6 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"daemon Inspection value.
|
||
unit : sec, default : 5
|
||
"
|
||
::= { sleFaultMonitorDaemonControl 7 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlCrashAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
restart(2),
|
||
switchover(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"daemon startup threshold value.
|
||
unit : sec, default : 100
|
||
"
|
||
::= { sleFaultMonitorDaemonControl 8 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlTimeoutAction OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
restart(2),
|
||
switchover(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate action when don't receive keepalive msg.
|
||
"
|
||
::= { sleFaultMonitorDaemonControl 9 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonControl 10 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlThreshed OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonControl 11 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlStartupThresh OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonControl 12 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlWatchdogAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonControl 13 }
|
||
|
||
|
||
sleFaultMonitorDaemonControlWatchdogThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (5..60)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonControl 14 }
|
||
|
||
|
||
sleFaultMonitorDaemonNotification OBJECT IDENTIFIER ::= { sleFaultMonitorDaemonConfig 4 }
|
||
|
||
|
||
setFaultMonitorDaemonAdminStatusChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlAdminStatus }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonNotification 1 }
|
||
|
||
|
||
setFaultMonitorDaemonFaultActionChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlCrashAction, sleFaultMonitorDaemonControlTimeoutAction
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonNotification 2 }
|
||
|
||
|
||
setFaultMonitorDaemonThresholdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonNotification 3 }
|
||
|
||
|
||
setFaultMonitorDaemonWatchdogchanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlWatchdogAdminStatus, sleFaultMonitorDaemonControlWatchdogThreshold
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorDaemonNotification 4 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinear OBJECT IDENTIFIER ::= { sleFaultMonitor 3 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearInfo OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 1 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate whether 2-points-linear monitoring is enabled or not
|
||
"
|
||
::= { sleFaultMonitor2pointsLinearInfo 1 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate 2-points-linear monitoring interval
|
||
default : 5, unit : sec
|
||
|
||
|
||
"
|
||
::= { sleFaultMonitor2pointsLinearInfo 2 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (1..60)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate 2-points-linear monitoring threshold
|
||
|
||
default : 8 times
|
||
"
|
||
::= { sleFaultMonitor2pointsLinearInfo 3 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearControl OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 2 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
set2PointsLinearAdminStatus(1),
|
||
set2PointsLinearInterval(2),
|
||
set2PointsLinearThreshold(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleFaultMonitor2pointsLinearControl 1 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleFaultMonitor2pointsLinearControl 2 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearControlTimer OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleFaultMonitor2pointsLinearControl 3 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleFaultMonitor2pointsLinearControl 4 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleFaultMonitor2pointsLinearControl 5 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearControlAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleFaultMonitor2pointsLinearControl 6 }
|
||
|
||
|
||
sleFaultMonitor2PonitsLinearControlInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate 2-points-linear monitoring interval
|
||
|
||
default : 5, unit : sec"
|
||
::= { sleFaultMonitor2pointsLinearControl 7 }
|
||
|
||
|
||
sleFaultMonitor2PointsLinearControlThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate 2-points-linear monitoring threshold
|
||
|
||
default : 8 times
|
||
"
|
||
::= { sleFaultMonitor2pointsLinearControl 8 }
|
||
|
||
|
||
sleFaultMonitor2pointsLinearNotification OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 3 }
|
||
|
||
|
||
sleFaultMonitor2PointsLinearAdminStatusChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2pointsLinearControlAdminStatus }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitor2pointsLinearNotification 1 }
|
||
|
||
|
||
sleFaultMonitor2PointsLinearIntervalChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2PonitsLinearControlInterval }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitor2pointsLinearNotification 2 }
|
||
|
||
|
||
sleFaultMonitor2PointsLinearThresholdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2PointsLinearControlThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitor2pointsLinearNotification 3 }
|
||
|
||
|
||
sleFaultMonitorRHM OBJECT IDENTIFIER ::= { sleFaultMonitor 4 }
|
||
|
||
|
||
sleFaultMonitorRHMInfo OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 1 }
|
||
|
||
|
||
sleFaultMonitorRHMAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM admin status"
|
||
::= { sleFaultMonitorRHMInfo 1 }
|
||
|
||
|
||
sleFaultMonitorRHMActionType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
switchover(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM action type
|
||
"
|
||
::= { sleFaultMonitorRHMInfo 2 }
|
||
|
||
|
||
sleFaultMonitorRHMActionThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (5..1000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM action threshold
|
||
"
|
||
::= { sleFaultMonitorRHMInfo 3 }
|
||
|
||
|
||
sleFaultMonitorRHMRebootThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (1..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM reboot threshold"
|
||
::= { sleFaultMonitorRHMInfo 4 }
|
||
|
||
|
||
sleFaultMonitorRHMRecoveryTime OBJECT-TYPE
|
||
SYNTAX Integer32 (10..14400)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM recovery time"
|
||
::= { sleFaultMonitorRHMInfo 5 }
|
||
|
||
|
||
sleFaultMonitorRHMFaultCounter OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM fault counter"
|
||
::= { sleFaultMonitorRHMInfo 6 }
|
||
|
||
|
||
sleFaultMonitorRHMRebootCounter OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM reboot counter"
|
||
::= { sleFaultMonitorRHMInfo 7 }
|
||
|
||
|
||
sleFaultMonitorRHMInterval OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMInfo 8 }
|
||
|
||
|
||
sleFaultMonitorRHMLiveThreshold OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMInfo 9 }
|
||
|
||
|
||
sleFaultMonitorRHMHostTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SleFaultMonitorRHMHostEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHM 2 }
|
||
|
||
|
||
sleFaultMonitorRHMHostEntry OBJECT-TYPE
|
||
SYNTAX SleFaultMonitorRHMHostEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sleFaultMonitorRHMHostAddr }
|
||
::= { sleFaultMonitorRHMHostTable 1 }
|
||
|
||
|
||
SleFaultMonitorRHMHostEntry ::=
|
||
SEQUENCE {
|
||
sleFaultMonitorRHMHostAddr
|
||
IpAddress
|
||
}
|
||
|
||
sleFaultMonitorRHMHostAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The target host or gateway address of RHM
|
||
"
|
||
::= { sleFaultMonitorRHMHostEntry 1 }
|
||
|
||
|
||
sleFaultMonitorRHMControl OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 3 }
|
||
|
||
|
||
sleFaultMonitorRHMControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setRHMStatus(1),
|
||
setRHMActionThreshold(2),
|
||
setRHMRebootThreshold(3),
|
||
setInterval(4),
|
||
setLiveThreshold(5),
|
||
clearRHMHost(6),
|
||
setRHMHost(7)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleFaultMonitorRHMControl 1 }
|
||
|
||
|
||
sleFaultMonitorRHMControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The status of a control request. "
|
||
::= { sleFaultMonitorRHMControl 2 }
|
||
|
||
|
||
sleFaultMonitorRHMControlTimer OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The maximum wait time for the manager for command ending.
|
||
For long running commands.
|
||
The manager reads this value from the DSLAM. "
|
||
::= { sleFaultMonitorRHMControl 3 }
|
||
|
||
|
||
sleFaultMonitorRHMControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The time stamp of the last command (end of command). "
|
||
::= { sleFaultMonitorRHMControl 4 }
|
||
|
||
|
||
sleFaultMonitorRHMControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The result of the last user command. "
|
||
::= { sleFaultMonitorRHMControl 5 }
|
||
|
||
|
||
sleFaultMonitorRHMControlAdminStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" "
|
||
::= { sleFaultMonitorRHMControl 6 }
|
||
|
||
|
||
sleFaultMonitorRHMControlActionType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
log(1),
|
||
switchover(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate 2-points-linear monitoring interval
|
||
|
||
default : 5, unit : sec"
|
||
::= { sleFaultMonitorRHMControl 7 }
|
||
|
||
|
||
sleFaultMonitorRHMControlActionThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (5..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM reboot threshold"
|
||
::= { sleFaultMonitorRHMControl 8 }
|
||
|
||
|
||
sleFaultMonitorRHMControlRebootThreshold OBJECT-TYPE
|
||
SYNTAX Integer32 (1..100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM reboot threshold"
|
||
::= { sleFaultMonitorRHMControl 9 }
|
||
|
||
|
||
sleFaultMonitorRHMControlRecoveryTime OBJECT-TYPE
|
||
SYNTAX Integer32 (10..14400)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The RHM recovery time"
|
||
::= { sleFaultMonitorRHMControl 10 }
|
||
|
||
|
||
sleFaultMonitorRHMControlInterval OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMControl 11 }
|
||
|
||
|
||
sleFaultMonitorRHMControlLiveThreshold OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMControl 12 }
|
||
|
||
|
||
sleFaultMonitorRHMControlHostAddr OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMControl 13 }
|
||
|
||
|
||
sleFaultMonitorRHMNotification OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 4 }
|
||
|
||
|
||
setRHMStatusChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlAdminStatus, sleFaultMonitorRHMControlActionType
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMNotification 1 }
|
||
|
||
|
||
setRHMActionThresholdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlActionThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMNotification 2 }
|
||
|
||
|
||
setRHMRebootThresholdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMNotification 3 }
|
||
|
||
|
||
setRHMHostAdded NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMNotification 4 }
|
||
|
||
|
||
setRHMHostCleared NOTIFICATION-TYPE
|
||
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMonitorRHMNotification 5 }
|
||
|
||
|
||
sle2EthernetCfm OBJECT IDENTIFIER ::= { sleFaultMgmt 17 }
|
||
|
||
|
||
sle2EthernetCfmBase OBJECT IDENTIFIER ::= { sle2EthernetCfm 1 }
|
||
|
||
|
||
sle2EthCfmBaseGroup OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 1 }
|
||
|
||
|
||
sle2EthCfmEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseGroup 1 }
|
||
|
||
|
||
sle2EthCfmLmmFrameCountSimStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
stop(0),
|
||
start(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseGroup 2 }
|
||
|
||
|
||
sle2EthCfmBaseControl OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 2 }
|
||
|
||
|
||
sle2EthCfmControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setCfmEnable(1),
|
||
setCfmLmmSimulator(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseControl 1 }
|
||
|
||
|
||
sle2EthCfmControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseControl 2 }
|
||
|
||
|
||
sle2EthCfmControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseControl 3 }
|
||
|
||
|
||
sle2EthCfmControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseControl 4 }
|
||
|
||
|
||
sle2EthCfmControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseControl 5 }
|
||
|
||
|
||
sle2EthCfmControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseControl 6 }
|
||
|
||
|
||
sle2EthCfmControlLmmFrameCountSimStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
stop(0),
|
||
start(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseControl 7 }
|
||
|
||
|
||
sle2EthCfmBaseNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 3 }
|
||
|
||
|
||
sle2EthCfmEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmControlRequest, sle2EthCfmControlReqResult, sle2EthCfmControlTimeStamp, sle2EthCfmEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseNotification 1 }
|
||
|
||
|
||
sle2EthCfmLmmFrameCountSimulatorChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmControlRequest, sle2EthCfmControlReqResult, sle2EthCfmControlTimeStamp, sle2EthCfmLmmFrameCountSimStatus }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBaseNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmBridge OBJECT IDENTIFIER ::= { sle2EthernetCfm 2 }
|
||
|
||
|
||
sle2EthCfmBridgeTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmBridgeEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmBridge 1 }
|
||
|
||
|
||
sle2EthCfmBridgeEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmBridgeEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId }
|
||
::= { sle2EthCfmBridgeTable 1 }
|
||
|
||
|
||
Sle2EthCfmBridgeEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmBridgeId
|
||
Integer32,
|
||
sle2EthCfmBridgeDefaultMdLevel
|
||
Integer32,
|
||
sle2EthCfmBridgeDefaultMepId
|
||
Integer32,
|
||
sle2EthCfmBridgeAutomatic
|
||
INTEGER,
|
||
sle2EthCfmBridgeConfigDefaultMdLevel
|
||
Integer32,
|
||
sle2EthCfmBridgeConfigDefaultMdMipCreation
|
||
INTEGER,
|
||
sle2EthCfmBridgeLtrCacheEnable
|
||
INTEGER,
|
||
sle2EthCfmBridgeLtrCacheSize
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 1 }
|
||
|
||
|
||
sle2EthCfmBridgeDefaultMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 2 }
|
||
|
||
|
||
sle2EthCfmBridgeDefaultMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 3 }
|
||
|
||
|
||
sle2EthCfmBridgeAutomatic OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 4 }
|
||
|
||
|
||
sle2EthCfmBridgeConfigDefaultMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 5 }
|
||
|
||
|
||
sle2EthCfmBridgeConfigDefaultMdMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 6 }
|
||
|
||
|
||
sle2EthCfmBridgeLtrCacheEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 7 }
|
||
|
||
|
||
sle2EthCfmBridgeLtrCacheSize OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeEntry 8 }
|
||
|
||
|
||
sle2EthCfmBridgeControl OBJECT IDENTIFIER ::= { sle2EthernetCfmBridge 2 }
|
||
|
||
|
||
sle2EthCfmBridgeControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setCfmBridgeProfile(1),
|
||
setCfmBridgeLtrCache(2),
|
||
clearCfmBridgeLtrChace(3),
|
||
setCfmBridgeAutomatic(4),
|
||
setCfmBridgeConfigDefaultMdLevel(5)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 1 }
|
||
|
||
|
||
sle2EthCfmBridgeControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 2 }
|
||
|
||
|
||
sle2EthCfmBridgeControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 3 }
|
||
|
||
|
||
sle2EthCfmBridgeControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 4 }
|
||
|
||
|
||
sle2EthCfmBridgeControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 5 }
|
||
|
||
|
||
sle2EthCfmBridgeControlId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 6 }
|
||
|
||
|
||
sle2EthCfmBridgeControlDefaultMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 7 }
|
||
|
||
|
||
sle2EthCfmBridgeControlDefaultMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 8 }
|
||
|
||
|
||
sle2EthCfmBridgeControlAutomatic OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 9 }
|
||
|
||
|
||
sle2EthCfmBridgeControlConfigDefaultMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 10 }
|
||
|
||
|
||
sle2EthCfmBridgeControlConfigDefaultMdMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 11 }
|
||
|
||
|
||
sle2EthCfmBridgeConntrolLtrCacheEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 12 }
|
||
|
||
|
||
sle2EthCfmBridgeControlLtrCacheSize OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeControl 13 }
|
||
|
||
|
||
sle2EthCfmBridgeNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmBridge 3 }
|
||
|
||
|
||
setCfmBridgeProfile NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeDefaultMdLevel,
|
||
sle2EthCfmBridgeDefaultMepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeNotification 1 }
|
||
|
||
|
||
setCfmBridgeLtrCacheEnable NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeLtrCacheSize,
|
||
sle2EthCfmBridgeLtrCacheEnable }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeNotification 2 }
|
||
|
||
|
||
clearCfmBridgeLtrCache NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeNotification 3 }
|
||
|
||
|
||
setCfmBridgeAutomatic NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeAutomatic
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeNotification 4 }
|
||
|
||
|
||
setCfmBridgeConfigDefaultMdLevel NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeConfigDefaultMdLevel,
|
||
sle2EthCfmBridgeConfigDefaultMdMipCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmBridgeNotification 5 }
|
||
|
||
|
||
sle2EhternetCfmVlan OBJECT IDENTIFIER ::= { sle2EthernetCfm 3 }
|
||
|
||
|
||
sle2EthernetCfmVlanConfig OBJECT IDENTIFIER ::= { sle2EhternetCfmVlan 1 }
|
||
|
||
|
||
sle2EthCfmVlanConfigTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmVlanConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmVlanConfig 1 }
|
||
|
||
|
||
sle2EthCfmVlanConfigEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmVlanConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmVlanConfigPrimaryVid, sle2EthCfmVlanConfigSecondaryVid }
|
||
::= { sle2EthCfmVlanConfigTable 1 }
|
||
|
||
|
||
Sle2EthCfmVlanConfigEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmVlanConfigPrimaryVid
|
||
Integer32,
|
||
sle2EthCfmVlanConfigSecondaryVid
|
||
Integer32,
|
||
sle2EthCfmVlanConfigSecondaryBridgeId
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmVlanConfigPrimaryVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigEntry 1 }
|
||
|
||
|
||
sle2EthCfmVlanConfigSecondaryVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigEntry 2 }
|
||
|
||
|
||
sle2EthCfmVlanConfigSecondaryBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigEntry 3 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControl OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanConfig 2 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
addCfmVlanConfVid(1),
|
||
delCfmVlanConfVid(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 1 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 2 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 3 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 4 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 5 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlPrimaryBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 6 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlPrimaryVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 7 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlSecondaryBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 8 }
|
||
|
||
|
||
sle2EthCfmVlanConfigControlSecondaryVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigControl 9 }
|
||
|
||
|
||
sle2EthCfmVlanConfigNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanConfig 3 }
|
||
|
||
|
||
addCfmVlanConfVid NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmVlanConfigPrimaryVid,
|
||
sle2EthCfmVlanConfigSecondaryVid, sle2EthCfmVlanConfigSecondaryBridgeId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigNotification 1 }
|
||
|
||
|
||
delCfmVlanConfVid NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmVlanConfigControlPrimaryBridgeId, sle2EthCfmVlanConfigControlPrimaryVid,
|
||
sle2EthCfmVlanConfigControlSecondaryBridgeId, sle2EthCfmVlanConfigControlSecondaryVid }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanConfigNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmVlanInfo OBJECT IDENTIFIER ::= { sle2EhternetCfmVlan 2 }
|
||
|
||
|
||
sle2EthCfmVlanInfoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmVlanInfoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmVlanInfo 1 }
|
||
|
||
|
||
sle2EthCfmVlanInfoEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmVlanInfoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmVlanInfoVid }
|
||
::= { sle2EthCfmVlanInfoTable 1 }
|
||
|
||
|
||
Sle2EthCfmVlanInfoEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmVlanInfoVid
|
||
Integer32,
|
||
sle2EthCfmVlanInfoPriority
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmVlanInfoVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoEntry 1 }
|
||
|
||
|
||
sle2EthCfmVlanInfoPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoEntry 2 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanInfo 2 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER { setCfmVlanPriority(1) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 1 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 2 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 3 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 4 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 5 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 6 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlVid OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 7 }
|
||
|
||
|
||
sle2EthCfmVlanInfoControlPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoControl 8 }
|
||
|
||
|
||
sle2EthCfmVlanInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanInfo 3 }
|
||
|
||
|
||
sle2EthCfmVlanPriorityChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmVlanInfoControlRequest, sle2EthCfmVlanInfoControlReqResult, sle2EthCfmVlanInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmVlanInfoVid,
|
||
sle2EthCfmVlanInfoPriority }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmVlanInfoNotification 1 }
|
||
|
||
|
||
sle2EthernetCfmDefMdLevelEntry OBJECT IDENTIFIER ::= { sle2EthernetCfm 4 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmDefMdLevelEntryEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmDefMdLevelEntry 1 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmDefMdLevelEntryEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmDefMdLevelEntryVid }
|
||
::= { sle2EthCfmDefMdLevelEntryTable 1 }
|
||
|
||
|
||
Sle2EthCfmDefMdLevelEntryEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmDefMdLevelEntryVid
|
||
Integer32,
|
||
sle2EthCfmDefMdLevelEntryLevel
|
||
Integer32,
|
||
sle2EthCfmDefMdLevelEntryMipCreation
|
||
INTEGER
|
||
}
|
||
|
||
sle2EthCfmDefMdLevelEntryVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryEntry 1 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryEntry 2 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryEntry 3 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControl OBJECT IDENTIFIER ::= { sle2EthernetCfmDefMdLevelEntry 2 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setCfmDefMdLevelEntry(1),
|
||
clearCfmDefMdLevelEntry(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 1 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 2 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 3 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 4 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 5 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 6 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 7 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 8 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryControlMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryControl 9 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmDefMdLevelEntry 3 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmDefMdLevelEntryControlRequest, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmDefMdLevelEntryVid,
|
||
sle2EthCfmDefMdLevelEntryLevel, sle2EthCfmDefMdLevelEntryMipCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryNotification 1 }
|
||
|
||
|
||
sle2EthCfmDefMdLevelEntryCleared NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmDefMdLevelEntryControlRequest, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmDefMdLevelEntryControlBridgeId, sle2EthCfmDefMdLevelEntryControlVid,
|
||
sle2EthCfmDefMdLevelEntryControlLevel, sle2EthCfmDefMdLevelEntryControlMipCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmDefMdLevelEntryNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmMd OBJECT IDENTIFIER ::= { sle2EthernetCfm 5 }
|
||
|
||
|
||
sle2EthCfmMdTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmMdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmMd 1 }
|
||
|
||
|
||
sle2EthCfmMdEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmMdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName }
|
||
::= { sle2EthCfmMdTable 1 }
|
||
|
||
|
||
Sle2EthCfmMdEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmMdName
|
||
OCTET STRING,
|
||
sle2EthCfmMdType
|
||
INTEGER,
|
||
sle2EthCfmMdLevel
|
||
Integer32,
|
||
sle2EthCfmMdMipCreation
|
||
INTEGER
|
||
}
|
||
|
||
sle2EthCfmMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdEntry 1 }
|
||
|
||
|
||
sle2EthCfmMdType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
noName(1),
|
||
dnsBased(2),
|
||
mac(3),
|
||
characterString(4),
|
||
ituT(32)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdEntry 2 }
|
||
|
||
|
||
sle2EthCfmMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdEntry 3 }
|
||
|
||
|
||
sle2EthCfmMdMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdEntry 4 }
|
||
|
||
|
||
sle2EthCfmMdControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMd 2 }
|
||
|
||
|
||
sle2EthCfmMdControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmMd(1),
|
||
destoryCfmMd(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 1 }
|
||
|
||
|
||
sle2EthCfmMdControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 2 }
|
||
|
||
|
||
sle2EthCfmMdControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 3 }
|
||
|
||
|
||
sle2EthCfmMdControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 4 }
|
||
|
||
|
||
sle2EthCfmMdControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 5 }
|
||
|
||
|
||
sle2EthCfmMdControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 6 }
|
||
|
||
|
||
sle2EthCfmMdControlType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
noName(1),
|
||
dnsBased(2),
|
||
mac(3),
|
||
characterString(4),
|
||
ituT(32)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 7 }
|
||
|
||
|
||
sle2EthCfmMdControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 8 }
|
||
|
||
|
||
sle2EthCfmMdControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 9 }
|
||
|
||
|
||
sle2EthCfmMdControlMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdControl 10 }
|
||
|
||
|
||
sle2EthCfmMdNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMd 3 }
|
||
|
||
|
||
sle2EthCfmMdCreated NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMdControlRequest, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMdType, sle2EthCfmMdLevel, sle2EthCfmMdMipCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdNotification 1 }
|
||
|
||
|
||
sle2EthCfmMdDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMdControlRequest, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlTimeStamp, sle2EthCfmMdControlBridgeId, sle2EthCfmMdControlName,
|
||
sle2EthCfmMdControlLevel, sle2EthCfmMdControlMipCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMdNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmMa OBJECT IDENTIFIER ::= { sle2EthernetCfm 6 }
|
||
|
||
|
||
sle2EthCfmMaTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmMaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmMa 1 }
|
||
|
||
|
||
sle2EthCfmMaEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmMaEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaName }
|
||
::= { sle2EthCfmMaTable 1 }
|
||
|
||
|
||
Sle2EthCfmMaEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmMaName
|
||
OCTET STRING,
|
||
sle2EthCfmMaVid
|
||
Integer32,
|
||
sle2EthCfmMaType
|
||
INTEGER,
|
||
sle2EthCfmMaMipCreation
|
||
INTEGER,
|
||
sle2EthCfmMaCcInterval
|
||
Integer32,
|
||
sle2EthCfmMaElmi
|
||
INTEGER,
|
||
sle2EthCfmMaConnectivityStatus
|
||
INTEGER,
|
||
sle2EthCfmMaConfiguredRmepCount
|
||
Integer32,
|
||
sle2EthCfmMaConvergedRmepCount
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmMaName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 1 }
|
||
|
||
|
||
sle2EthCfmMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 2 }
|
||
|
||
|
||
sle2EthCfmMaType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
primaryVid(1),
|
||
string(2),
|
||
integer(3),
|
||
vpnId(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 3 }
|
||
|
||
|
||
sle2EthCfmMaMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3),
|
||
defer(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 4 }
|
||
|
||
|
||
sle2EthCfmMaCcInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 5 }
|
||
|
||
|
||
sle2EthCfmMaElmi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 6 }
|
||
|
||
|
||
sle2EthCfmMaConnectivityStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknow(1),
|
||
active(2),
|
||
partiallyActive(3),
|
||
notActive(4),
|
||
error(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 7 }
|
||
|
||
|
||
sle2EthCfmMaConfiguredRmepCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 8 }
|
||
|
||
|
||
sle2EthCfmMaConvergedRmepCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaEntry 9 }
|
||
|
||
|
||
sle2EthCfmMaControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMa 2 }
|
||
|
||
|
||
sle2EthCfmMaControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmMa(1),
|
||
destoryCfmMa(2),
|
||
setCfmCcInterval(3),
|
||
setCfmElmi(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 1 }
|
||
|
||
|
||
sle2EthCfmMaControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 2 }
|
||
|
||
|
||
sle2EthCfmMaControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 3 }
|
||
|
||
|
||
sle2EthCfmMaControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 4 }
|
||
|
||
|
||
sle2EthCfmMaControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 5 }
|
||
|
||
|
||
sle2EthCfmMaControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 6 }
|
||
|
||
|
||
sle2EthCfmMaControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 7 }
|
||
|
||
|
||
sle2EthCfmMaControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 8 }
|
||
|
||
|
||
sle2EthCfmMaControlType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
primaryVid(1),
|
||
string(2),
|
||
integer(3),
|
||
vpnId(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 9 }
|
||
|
||
|
||
sle2EthCfmMaControlVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 10 }
|
||
|
||
|
||
sle2EthCfmMaControlMipCreation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(1),
|
||
default(2),
|
||
explicit(3),
|
||
defer(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 11 }
|
||
|
||
|
||
sle2EthCfmMaControlCcmInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 12 }
|
||
|
||
|
||
sle2EthCfmMaControlElmi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaControl 13 }
|
||
|
||
|
||
sle2EthCfmMaNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMa 3 }
|
||
|
||
|
||
sle2EthCfmMaCreated NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaName, sle2EthCfmMaVid, sle2EthCfmMaType, sle2EthCfmMaMipCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaNotification 1 }
|
||
|
||
|
||
sle2EthCfmMaDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmMaControlBridgeId, sle2EthCfmMaControlMdName,
|
||
sle2EthCfmMaControlName, sle2EthCfmMaControlVid, sle2EthCfmMaControlMipCreation }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaNotification 2 }
|
||
|
||
|
||
sle2EthCfmCcIntervalChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMaCcInterval }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaNotification 3 }
|
||
|
||
|
||
sle2EthCfmElmiChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaName, sle2EthCfmMaElmi }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMaNotification 4 }
|
||
|
||
|
||
sle2EthernetCfmMep OBJECT IDENTIFIER ::= { sle2EthernetCfm 7 }
|
||
|
||
|
||
sle2EthernetCfmMepInfo OBJECT IDENTIFIER ::= { sle2EthernetCfmMep 1 }
|
||
|
||
|
||
sle2EthCfmMepInfoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmMepInfoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmMepInfo 1 }
|
||
|
||
|
||
sle2EthCfmMepInfoEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmMepInfoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
|
||
::= { sle2EthCfmMepInfoTable 1 }
|
||
|
||
|
||
Sle2EthCfmMepInfoEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmMepInfoId
|
||
Integer32,
|
||
sle2EthCfmMepInfoIfindex
|
||
Integer32,
|
||
sle2EthCfmMepInfoLocalVid
|
||
Integer32,
|
||
sle2EthCfmMepInfoDirection
|
||
INTEGER,
|
||
sle2EthCfmMepInfoActive
|
||
INTEGER,
|
||
sle2EthCfmMepInfoUNI
|
||
INTEGER,
|
||
sle2EthCfmMepInfoCcmStatus
|
||
INTEGER,
|
||
sle2EthCfmMepInfoCcmType
|
||
INTEGER,
|
||
sle2EthCfmMepInfoCcmRmepId
|
||
Integer32,
|
||
sle2EthCfmMepInfoLocalMacAddr
|
||
OCTET STRING,
|
||
sle2EthCfmMepInfoRdi
|
||
INTEGER,
|
||
sle2EthCfmMepInfoService
|
||
INTEGER,
|
||
sle2EthCfmMepInfoLckLevel
|
||
Integer32,
|
||
sle2EthCfmMepInfoDlmState
|
||
INTEGER,
|
||
sle2EthCfmMepInfoDlmRmepId
|
||
Integer32,
|
||
sle2EthCfmMepInfoConnectivityStatus
|
||
INTEGER,
|
||
sle2EthCfmMepInfoInterval
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmMepInfoId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 1 }
|
||
|
||
|
||
sle2EthCfmMepInfoIfindex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 2 }
|
||
|
||
|
||
sle2EthCfmMepInfoLocalVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 3 }
|
||
|
||
|
||
sle2EthCfmMepInfoDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
down(1),
|
||
up(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 4 }
|
||
|
||
|
||
sle2EthCfmMepInfoActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 5 }
|
||
|
||
|
||
sle2EthCfmMepInfoUNI OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 6 }
|
||
|
||
|
||
sle2EthCfmMepInfoCcmStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 7 }
|
||
|
||
|
||
sle2EthCfmMepInfoCcmType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unicast(1),
|
||
multicast(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 8 }
|
||
|
||
|
||
sle2EthCfmMepInfoCcmRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 9 }
|
||
|
||
|
||
sle2EthCfmMepInfoLocalMacAddr OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 10 }
|
||
|
||
|
||
sle2EthCfmMepInfoRdi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 11 }
|
||
|
||
|
||
sle2EthCfmMepInfoService OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
inService(0),
|
||
outOfService(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 12 }
|
||
|
||
|
||
sle2EthCfmMepInfoLckLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 13 }
|
||
|
||
|
||
sle2EthCfmMepInfoDlmState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 14 }
|
||
|
||
|
||
sle2EthCfmMepInfoDlmRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 15 }
|
||
|
||
|
||
sle2EthCfmMepInfoConnectivityStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
isolated(1),
|
||
fully(2),
|
||
partially(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 16 }
|
||
|
||
|
||
sle2EthCfmMepInfoInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoEntry 17 }
|
||
|
||
|
||
sle2EthCfmMepInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMepInfo 2 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createEthCfmMep(1),
|
||
destoryEthCfmMep(2),
|
||
setEthCfmCcEnable(3),
|
||
setEthCfmService(4),
|
||
setEthCfmDlmm(5),
|
||
tarnsmitUnicastTst(6),
|
||
tarnsmitMulticastTst(7),
|
||
transmitUnicastLm(8),
|
||
transmitMulticastLm(9),
|
||
transmitUnicastDm(10),
|
||
transmitMulticastDm(11),
|
||
receive1Dm(12),
|
||
transmitTm(13),
|
||
receiveTm(14),
|
||
transmitExm(15),
|
||
transmitVsm(16),
|
||
transmitMcc(17)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 1 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 2 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 3 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 4 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 5 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 6 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 7 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 8 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlIfindex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 9 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 10 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlLocalVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 11 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlMepDirection OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
down(1),
|
||
up(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 12 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 13 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlUNI OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 14 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlCcmStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 15 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlFrameType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unicast(1),
|
||
multicast(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 16 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 17 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlService OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
inService(0),
|
||
outOfService(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 18 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlDlmState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 19 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlLckLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 20 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlTstPattern OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 21 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlTstRecursive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 22 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlDuration OBJECT-TYPE
|
||
SYNTAX Integer32 (5..60)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 23 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlTstTxInterval OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 24 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlTstLckInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1 | 60)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 25 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlLckRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoControl 26 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates interval value.
|
||
1: 100ms
|
||
2: 10ms
|
||
3: 1s
|
||
4: 10s
|
||
"
|
||
::= { sle2EthCfmMepInfoControl 27 }
|
||
|
||
|
||
sle2EthCfmMepInfoControlTransMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
oneDm(1),
|
||
dvm(2),
|
||
dmm(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the transmit mode."
|
||
::= { sle2EthCfmMepInfoControl 28 }
|
||
|
||
|
||
sle2EthCfmMepInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMepInfo 3 }
|
||
|
||
|
||
sle2EthCfmMepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoLocalVid, sle2EthCfmMepInfoDirection,
|
||
sle2EthCfmMepInfoActive, sle2EthCfmMepInfoUNI }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 1 }
|
||
|
||
|
||
sle2EthCfmMepDestory NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlIfindex, sle2EthCfmMepInfoControlMepDirection, sle2EthCfmMepInfoControlLocalVid
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 2 }
|
||
|
||
|
||
sle2EthCfmCcEnableChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoCcmFrameType, sle2EthCfmMepInfoCcmStatus, sle2EthCfmMepInfoCcmRmepId
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 3 }
|
||
|
||
|
||
sle2EthCfmServiceChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoService, sle2EthCfmMepInfoLckLevel }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 4 }
|
||
|
||
|
||
sle2EthCfmDualEndLmmChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoDlmState, sle2EthCfmMepInfoDlmRmepId
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 5 }
|
||
|
||
|
||
sle2EthCfmTransmitUnicastTstFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive,
|
||
sle2EthCfmMepInfoControlTstTxInterval, sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepInfoControlDuration
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 6 }
|
||
|
||
|
||
sle2EthCfmTransmitMulticastTstFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive, sle2EthCfmMepInfoControlTstTxInterval,
|
||
sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepInfoControlDuration }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 7 }
|
||
|
||
|
||
sle2EthCfmTransmitUnicastLmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 8 }
|
||
|
||
|
||
sle2EthCfmTransmitMulticastLmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 9 }
|
||
|
||
|
||
sle2EthCfmTransmitUnicastDmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTransMode, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlDuration,
|
||
sle2EthCfmMepInfoControlInterval }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 10 }
|
||
|
||
|
||
sle2EthCfmTransmitMuliticastDmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTransMode, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 11 }
|
||
|
||
|
||
sle2EthCfmReceive1DmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 12 }
|
||
|
||
|
||
sle2EthCfmTransmitTmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 13 }
|
||
|
||
|
||
sle2EthCfmReceiveTmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 14 }
|
||
|
||
|
||
sle2EthCfmTransmitExmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 15 }
|
||
|
||
|
||
sle2EthCfmTransmitVsmFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 16 }
|
||
|
||
|
||
sle2EthCfmTransmitMccFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlRmepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepInfoNotification 17 }
|
||
|
||
|
||
sle2EthernetCfmMepAttributs OBJECT IDENTIFIER ::= { sle2EthernetCfmMep 2 }
|
||
|
||
|
||
sle2EthCfmMepAttrTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmMepAttrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmMepAttributs 1 }
|
||
|
||
|
||
sle2EthCfmMepAttrEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmMepAttrEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
|
||
::= { sle2EthCfmMepAttrTable 1 }
|
||
|
||
|
||
Sle2EthCfmMepAttrEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmMepAttrActive
|
||
INTEGER,
|
||
sle2EthCfmMepAttrCcmLtmPriority
|
||
Integer32,
|
||
sle2EthCfmMepAttrLowPrDef
|
||
INTEGER,
|
||
sle2EthCfmMepAttrFngAlarmTime
|
||
Integer32,
|
||
sle2EthCfmMepAttrResetFngTime
|
||
Integer32,
|
||
sle2EthCfmMepAttrCcmLtmFlag
|
||
Integer32,
|
||
sle2EthCfmMepAttrTxLtmTargetMac
|
||
OCTET STRING,
|
||
sle2EthCfmMepAttrTxLtmTargetMepId
|
||
Integer32,
|
||
sle2EthCfmMepAttrTxLtmTargetIsMepId
|
||
INTEGER,
|
||
sle2EthCfmMepAttrTxLtmTtl
|
||
Integer32,
|
||
sle2EthCfmMepAttrTxLtmEgressId
|
||
OCTET STRING,
|
||
sle2EthCfmMepAttrTxLbmStatus
|
||
INTEGER,
|
||
sle2EthCfmMepAttrTxLbmDestMac
|
||
OCTET STRING,
|
||
sle2EthCfmMepAttrTxLbmDestMepId
|
||
Integer32,
|
||
sle2EthCfmMepAttrTxLbmDestIsMepId
|
||
INTEGER,
|
||
sle2EthCfmMepAttrTxLbmMessages
|
||
Integer32,
|
||
sle2EthCfmMepAttrTxLbmDataTlv
|
||
OCTET STRING,
|
||
sle2EthCfmMepAttrTxLbmVlanPriority
|
||
Integer32,
|
||
sle2EthCfmMepAttrTxLbmVlanDropEnable
|
||
INTEGER,
|
||
sle2EthCfmMepAttrTxLbmTimeOut
|
||
Integer32,
|
||
sle2EthCfmMepAttrLbrTimeOut
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmMepAttrActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 1 }
|
||
|
||
|
||
sle2EthCfmMepAttrCcmLtmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 2 }
|
||
|
||
|
||
sle2EthCfmMepAttrLowPrDef OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
allDef(1),
|
||
macRemErrXcon(2),
|
||
remErrXcon(3),
|
||
errXcon(4),
|
||
xcon(5),
|
||
noXcon(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 3 }
|
||
|
||
|
||
sle2EthCfmMepAttrFngAlarmTime OBJECT-TYPE
|
||
SYNTAX Integer32 (250..1000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 4 }
|
||
|
||
|
||
sle2EthCfmMepAttrResetFngTime OBJECT-TYPE
|
||
SYNTAX Integer32 (250..1000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 5 }
|
||
|
||
|
||
sle2EthCfmMepAttrCcmLtmFlag OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 6 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLtmTargetMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 7 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLtmTargetMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 8 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLtmTargetIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 9 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLtmTtl OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 10 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLtmEgressId OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 11 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 12 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmDestMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 13 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (0..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 14 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmDestIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 15 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmMessages OBJECT-TYPE
|
||
SYNTAX Integer32 (1..5)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 16 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmDataTlv OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 17 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmVlanPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 18 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmVlanDropEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 19 }
|
||
|
||
|
||
sle2EthCfmMepAttrTxLbmTimeOut OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 20 }
|
||
|
||
|
||
sle2EthCfmMepAttrLbrTimeOut OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrEntry 21 }
|
||
|
||
|
||
sle2EthCfmMepAttrControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMepAttributs 2 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setCfmFaultProfile(1),
|
||
setCfmTxLtmProfile(2),
|
||
setCfmTxLbmProfile(3),
|
||
clearAllCfmMepAttuributes(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 1 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 2 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 3 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 4 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 5 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 6 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 7 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (0..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 8 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 9 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 10 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlCcmLtmPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 11 }
|
||
|
||
|
||
sle2EthCfmMepAttrContrlLowPrDef OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
allDef(1),
|
||
macRemErrXcon(2),
|
||
remErrXcon(3),
|
||
errXcon(4),
|
||
xcon(5),
|
||
noXcon(6)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 12 }
|
||
|
||
|
||
sle2EthCfmMepAttrContrlFngAlarmTime OBJECT-TYPE
|
||
SYNTAX Integer32 (250..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 13 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlResetFngTime OBJECT-TYPE
|
||
SYNTAX Integer32 (250..1000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 14 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlCcmLtmFlag OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 15 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLtmTargetMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 16 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLtmTargetMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (0..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 17 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLtmTargetIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 18 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLtmTtl OBJECT-TYPE
|
||
SYNTAX Integer32 (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 19 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLtmEgressId OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 20 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 21 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmDestMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 22 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmDestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (0..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 23 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmDestIsMepId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 24 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmMessages OBJECT-TYPE
|
||
SYNTAX Integer32 (1..5)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 25 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmDataTlv OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 26 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmVlanPriority OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 27 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmVlanDropEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 28 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlTxLbmTimeOut OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 29 }
|
||
|
||
|
||
sle2EthCfmMepAttrControlLbrTimeOut OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrControl 30 }
|
||
|
||
|
||
sle2EthCfmMepAttrNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMepAttributs 3 }
|
||
|
||
|
||
sle2EthCfmMepFaultProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrCcmLtmPriority, sle2EthCfmMepAttrLowPrDef, sle2EthCfmMepAttrFngAlarmTime,
|
||
sle2EthCfmMepAttrResetFngTime, sle2EthCfmMepAttrActive }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrNotification 1 }
|
||
|
||
|
||
sle2EthCfmMepTxLtmProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrCcmLtmFlag, sle2EthCfmMepAttrTxLtmTargetMac, sle2EthCfmMepAttrTxLtmTargetMepId,
|
||
sle2EthCfmMepAttrTxLtmTargetIsMepId, sle2EthCfmMepAttrTxLtmTtl, sle2EthCfmMepAttrTxLtmEgressId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrNotification 2 }
|
||
|
||
|
||
sle2EthCfmMepTxLbmProfileChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrTxLbmStatus, sle2EthCfmMepAttrTxLbmDestMac, sle2EthCfmMepAttrTxLbmDestMepId,
|
||
sle2EthCfmMepAttrTxLbmDestIsMepId, sle2EthCfmMepAttrTxLbmMessages, sle2EthCfmMepAttrTxLbmDataTlv, sle2EthCfmMepAttrTxLbmVlanPriority, sle2EthCfmMepAttrTxLbmVlanDropEnable,
|
||
sle2EthCfmMepAttrTxLbmTimeOut, sle2EthCfmMepAttrLbrTimeOut }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrNotification 3 }
|
||
|
||
|
||
sle2EthCfmMepAuttributesAllCleared NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMepAttrNotification 4 }
|
||
|
||
|
||
sle2EthernetCfmXcheck OBJECT IDENTIFIER ::= { sle2EthernetCfm 8 }
|
||
|
||
|
||
sle2EthCfmXcheckTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmXcheckEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmXcheck 1 }
|
||
|
||
|
||
sle2EthCfmXcheckEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmXcheckEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmXcheckRmepId }
|
||
::= { sle2EthCfmXcheckTable 1 }
|
||
|
||
|
||
Sle2EthCfmXcheckEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmXcheckRmepId
|
||
Integer32,
|
||
sle2EthCfmXcheckRmepMac
|
||
OCTET STRING
|
||
}
|
||
|
||
sle2EthCfmXcheckRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckEntry 1 }
|
||
|
||
|
||
sle2EthCfmXcheckRmepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckEntry 2 }
|
||
|
||
|
||
sle2EthCfmXcheckControl OBJECT IDENTIFIER ::= { sle2EthernetCfmXcheck 2 }
|
||
|
||
|
||
sle2EthCfmXcheckControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createCfmXcheckMep(1),
|
||
destoryCfmXcheckMep(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 1 }
|
||
|
||
|
||
sle2EthCfmXcheckControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 2 }
|
||
|
||
|
||
sle2EthCfmXcheckControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 3 }
|
||
|
||
|
||
sle2EthCfmXcheckControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 4 }
|
||
|
||
|
||
sle2EthCfmXcheckControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 5 }
|
||
|
||
|
||
sle2EthCfmXcheckControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 6 }
|
||
|
||
|
||
sle2EthCfmXcheckControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 7 }
|
||
|
||
|
||
sle2EthCfmXcheckControlMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 8 }
|
||
|
||
|
||
sle2EthCfmXcheckControlRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 9 }
|
||
|
||
|
||
sle2EthCfmXcheckControlRmepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckControl 10 }
|
||
|
||
|
||
sle2EthCfmXcheckNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmXcheck 3 }
|
||
|
||
|
||
sle2EthCfmXcheckMepCreated NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlReqResult, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmXcheckRmepId, sle2EthCfmXcheckRmepMac }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckNotification 1 }
|
||
|
||
|
||
sle2EthCfmXcheckMepDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlReqResult, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmXcheckControlBridgeId, sle2EthCfmXcheckControlMdName,
|
||
sle2EthCfmXcheckControlMaVid, sle2EthCfmXcheckControlRmepId, sle2EthCfmXcheckControlRmepMac }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmXcheckNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmLoopback OBJECT IDENTIFIER ::= { sle2EthernetCfm 9 }
|
||
|
||
|
||
sle2EthCfmLoopbackTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmLoopbackEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmLoopback 1 }
|
||
|
||
|
||
sle2EthCfmLoopbackEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmLoopbackEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
|
||
::= { sle2EthCfmLoopbackTable 1 }
|
||
|
||
|
||
Sle2EthCfmLoopbackEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmLbFrameType
|
||
INTEGER,
|
||
sle2EthCfmLbReceivedCount
|
||
Integer32,
|
||
sle2EthCfmLbTxMessages
|
||
Integer32,
|
||
sle2EthCfmLbResponseCount
|
||
Integer32,
|
||
sle2EthCfmLbRemoteMacAddress
|
||
OCTET STRING
|
||
}
|
||
|
||
sle2EthCfmLbFrameType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unicast(1),
|
||
multicast(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackEntry 1 }
|
||
|
||
|
||
sle2EthCfmLbReceivedCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackEntry 2 }
|
||
|
||
|
||
sle2EthCfmLbTxMessages OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackEntry 3 }
|
||
|
||
|
||
sle2EthCfmLbResponseCount OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackEntry 4 }
|
||
|
||
|
||
sle2EthCfmLbRemoteMacAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackEntry 5 }
|
||
|
||
|
||
sle2EthCfmLoopbackControl OBJECT IDENTIFIER ::= { sle2EthernetCfmLoopback 2 }
|
||
|
||
|
||
sle2EthCfmLbControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
transmitMulticastLb(1),
|
||
transmitUnicastLb(2),
|
||
transmitMacLb(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 1 }
|
||
|
||
|
||
sle2EthCfmLbControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 2 }
|
||
|
||
|
||
sle2EthCfmLbControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 3 }
|
||
|
||
|
||
sle2EthCfmLbControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 4 }
|
||
|
||
|
||
sle2EthCfmLbControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 5 }
|
||
|
||
|
||
sle2EthCfmLbControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 6 }
|
||
|
||
|
||
sle2EthCfmLbControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 7 }
|
||
|
||
|
||
sle2EthCfmLbControlMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 8 }
|
||
|
||
|
||
sle2EthCfmLbControlMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 9 }
|
||
|
||
|
||
sle2EthCfmLbControlMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 10 }
|
||
|
||
|
||
sle2EthCfmLbControlRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 11 }
|
||
|
||
|
||
sle2EthCfmLbControlRmepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 12 }
|
||
|
||
|
||
sle2EthCfmLbControlTlvType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
tlvData(1),
|
||
tlvTest(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 13 }
|
||
|
||
|
||
sle2EthCfmLbControlTlvData OBJECT-TYPE
|
||
SYNTAX Integer32 (1..9000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 14 }
|
||
|
||
|
||
sle2EthCfmLbControlTlvTest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
pattern1(1),
|
||
pattern2(2),
|
||
pattern3(3),
|
||
pattern4(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 15 }
|
||
|
||
|
||
sle2EthCfmLbControlRecursive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackControl 16 }
|
||
|
||
|
||
sle2EthCfmLoopbackNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmLoopback 3 }
|
||
|
||
|
||
sle2EthCfmLbTransmitMulticastFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName,
|
||
sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlTlvType, sle2EthCfmLbControlTlvData,
|
||
sle2EthCfmLbControlTlvTest, sle2EthCfmLbControlRecursive }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackNotification 1 }
|
||
|
||
|
||
sle2EthCfmLbTransmitUnicastFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName,
|
||
sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepId, sle2EthCfmLbControlTlvType,
|
||
sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackNotification 2 }
|
||
|
||
|
||
sle2EthCfmLbTransmitMacFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName,
|
||
sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepMac, sle2EthCfmLbControlTlvType,
|
||
sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackNotification 3 }
|
||
|
||
|
||
sle2EthCfmLbrFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmLbFrameType, sle2EthCfmLbReceivedCount, sle2EthCfmLbRemoteMacAddress,
|
||
sle2EthCfmLbTxMessages, sle2EthCfmLbResponseCount }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLoopbackNotification 4 }
|
||
|
||
|
||
sle2EthernetCfmLinkTrace OBJECT IDENTIFIER ::= { sle2EthernetCfm 10 }
|
||
|
||
|
||
sle2EthCfmLinkTraceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmLinkTraceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmLinkTrace 1 }
|
||
|
||
|
||
sle2EthCfmLinkTraceEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmLinkTraceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
|
||
::= { sle2EthCfmLinkTraceTable 1 }
|
||
|
||
|
||
Sle2EthCfmLinkTraceEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmLtrMepMac
|
||
OCTET STRING,
|
||
sle2EthCfmLtrHops
|
||
Integer32,
|
||
sle2EthCfmLtrRelay
|
||
INTEGER,
|
||
sle2EthCfmLtrIngressEgress
|
||
INTEGER,
|
||
sle2EthCfmLtrIngress
|
||
INTEGER,
|
||
sle2EthCfmLtrEgress
|
||
INTEGER
|
||
}
|
||
|
||
sle2EthCfmLtrMepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceEntry 1 }
|
||
|
||
|
||
sle2EthCfmLtrHops OBJECT-TYPE
|
||
SYNTAX Integer32 (1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceEntry 2 }
|
||
|
||
|
||
sle2EthCfmLtrRelay OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(0),
|
||
rlyHit(1),
|
||
rlyFDB(2),
|
||
rlyMPDB(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceEntry 3 }
|
||
|
||
|
||
sle2EthCfmLtrIngressEgress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ingress(1),
|
||
egress(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceEntry 4 }
|
||
|
||
|
||
sle2EthCfmLtrIngress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
ingNoTlv(0),
|
||
ingOK(1),
|
||
ingDown(2),
|
||
ingBlocked(3),
|
||
ingVid(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceEntry 5 }
|
||
|
||
|
||
sle2EthCfmLtrEgress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
egrNoTlv(0),
|
||
egrOK(1),
|
||
egrDown(2),
|
||
egrBlocked(3),
|
||
egrVid(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceEntry 6 }
|
||
|
||
|
||
sle2EthCfmLinkTraceControl OBJECT IDENTIFIER ::= { sle2EthernetCfmLinkTrace 2 }
|
||
|
||
|
||
sle2EthCfmLtControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
transmitLtDomain(1),
|
||
transmitLtLevel(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 1 }
|
||
|
||
|
||
sle2EthCfmLtControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 2 }
|
||
|
||
|
||
sle2EthCfmLtControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 3 }
|
||
|
||
|
||
sle2EthCfmLtControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 4 }
|
||
|
||
|
||
sle2EthCfmLtControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 5 }
|
||
|
||
|
||
sle2EthCfmLtControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 6 }
|
||
|
||
|
||
sle2EthCfmLtControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 7 }
|
||
|
||
|
||
sle2EthCfmLtControlMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 8 }
|
||
|
||
|
||
sle2EthCfmLtControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 9 }
|
||
|
||
|
||
sle2EthCfmLtControlRmepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceControl 10 }
|
||
|
||
|
||
sle2EthCfmLtControlMepId OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"indicates mepid of local."
|
||
::= { sle2EthCfmLinkTraceControl 11 }
|
||
|
||
|
||
sle2EthCfmLinkTraceNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmLinkTrace 3 }
|
||
|
||
|
||
sle2EthCfmLtTransmitDomainFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMdName,
|
||
sle2EthCfmLtControlMaVid, sle2EthCfmLtControlRmepMac }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceNotification 1 }
|
||
|
||
|
||
sle2EthCfmLtTransmitLevelFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMaVid,
|
||
sle2EthCfmLtControlLevel, sle2EthCfmLtControlRmepMac }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceNotification 2 }
|
||
|
||
|
||
sle2EthCfmLtrFinished NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
|
||
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmLtrMepMac, sle2EthCfmLtrHops, sle2EthCfmLtrRelay,
|
||
sle2EthCfmLtrIngressEgress, sle2EthCfmLtrIngress, sle2EthCfmLtrEgress }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLinkTraceNotification 3 }
|
||
|
||
|
||
sle2EthernetCfmAis OBJECT IDENTIFIER ::= { sle2EthernetCfm 11 }
|
||
|
||
|
||
sle2EthernetCfmAisInfo OBJECT IDENTIFIER ::= { sle2EthernetCfmAis 1 }
|
||
|
||
|
||
sle2EthCfmAisInfoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmAisInfoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmAisInfo 1 }
|
||
|
||
|
||
sle2EthCfmAisInfoEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmAisInfoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoDefectConditions,
|
||
sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoRmepMac }
|
||
::= { sle2EthCfmAisInfoTable 1 }
|
||
|
||
|
||
Sle2EthCfmAisInfoEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmAisInfoStatus
|
||
INTEGER,
|
||
sle2EthCfmAisInfoDefectConditions
|
||
INTEGER,
|
||
sle2EthCfmAisInfoLevel
|
||
Integer32,
|
||
sle2EthCfmAisInfoFrameType
|
||
INTEGER,
|
||
sle2EthCfmAisInfoRmepMac
|
||
OCTET STRING,
|
||
sle2EthCfmAisInfoInterval
|
||
Integer32,
|
||
sle2EthCfmAisInfoReceivedDefectConditions
|
||
INTEGER,
|
||
sle2EthCfmAisInfoLastReceivedDefectCondition
|
||
INTEGER
|
||
}
|
||
|
||
sle2EthCfmAisInfoStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 1 }
|
||
|
||
|
||
sle2EthCfmAisInfoDefectConditions OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
all(1),
|
||
loc(2),
|
||
mismerge(3),
|
||
unexpectedMep(4),
|
||
unexpectedMegLevel(5),
|
||
unexpectedPeriod(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 2 }
|
||
|
||
|
||
sle2EthCfmAisInfoLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 3 }
|
||
|
||
|
||
sle2EthCfmAisInfoFrameType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unicast(1),
|
||
multicast(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 4 }
|
||
|
||
|
||
sle2EthCfmAisInfoRmepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 5 }
|
||
|
||
|
||
sle2EthCfmAisInfoInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 6 }
|
||
|
||
|
||
sle2EthCfmAisInfoReceivedDefectConditions OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
all(1),
|
||
loc(2),
|
||
mismerge(3),
|
||
unexpectedMep(4),
|
||
unexpectedMegLevel(5),
|
||
unexpectedPeriod(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 7 }
|
||
|
||
|
||
sle2EthCfmAisInfoLastReceivedDefectCondition OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
all(1),
|
||
loc(2),
|
||
mismerge(3),
|
||
unexpectedMep(4),
|
||
unexpectedMegLevel(5),
|
||
unexpectedPeriod(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoEntry 8 }
|
||
|
||
|
||
sle2EthCfmAisInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmAisInfo 2 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
setCfmAisInfoStatus(1),
|
||
setCfmAisInfoInterval(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 1 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 2 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 3 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 4 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 5 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 6 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 7 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 8 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 9 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 10 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlDefectConditions OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
all(1),
|
||
loc(2),
|
||
mismerge(3),
|
||
unexpectedMep(4),
|
||
unexpectedMegLevel(5),
|
||
unexpectedPeriod(6)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 11 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 12 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlFrameType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unicast(1),
|
||
multicast(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 13 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlRmepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 14 }
|
||
|
||
|
||
sle2EthCfmAisInfoControlInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoControl 15 }
|
||
|
||
|
||
sle2EthCfmAisInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmAisInfo 3 }
|
||
|
||
|
||
sle2EthCfmAisInfoStatusChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoStatus,
|
||
sle2EthCfmAisInfoDefectConditions, sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoFrameType, sle2EthCfmAisInfoRmepMac }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoNotification 1 }
|
||
|
||
|
||
sle2EthCfmAisInfoIntervalChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoInterval
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmAisInfoNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmSrvAis OBJECT IDENTIFIER ::= { sle2EthernetCfmAis 2 }
|
||
|
||
|
||
sle2EthCfmSrvAisTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmSrvAisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmSrvAis 1 }
|
||
|
||
|
||
sle2EthCfmSrvAisEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmSrvAisEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmSrvAisIfIndex }
|
||
::= { sle2EthCfmSrvAisTable 1 }
|
||
|
||
|
||
Sle2EthCfmSrvAisEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmSrvAisIfIndex
|
||
Integer32,
|
||
sle2EthCfmSrvAisEnable
|
||
INTEGER,
|
||
sle2EthCfmSrvAislevel
|
||
Integer32,
|
||
sle2EthCfmSrvAisInterval
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmSrvAisIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisEntry 1 }
|
||
|
||
|
||
sle2EthCfmSrvAisEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisEntry 2 }
|
||
|
||
|
||
sle2EthCfmSrvAislevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisEntry 3 }
|
||
|
||
|
||
sle2EthCfmSrvAisInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisEntry 4 }
|
||
|
||
|
||
sle2EthCfmSrvAisControl OBJECT IDENTIFIER ::= { sle2EthernetCfmSrvAis 2 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER { setCfmSrvAisEnable(1) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 1 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 2 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 3 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 4 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 5 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 6 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 7 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 8 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 9 }
|
||
|
||
|
||
sle2EthCfmSrvAisControlInterval OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisControl 10 }
|
||
|
||
|
||
sle2EthCfmSrvAisNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmSrvAis 3 }
|
||
|
||
|
||
sle2EthCfmSrvAisChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmBridgeId, sle2EthCfmSrvAisIfIndex, sle2EthCfmSrvAisEnable, sle2EthCfmSrvAislevel, sle2EthCfmSrvAisInterval
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmSrvAisNotification 1 }
|
||
|
||
|
||
sle2EthernetCfmLmStatus OBJECT IDENTIFIER ::= { sle2EthernetCfm 12 }
|
||
|
||
|
||
sle2EthCfmLmmStatusTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmLmmStatusEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmLmStatus 1 }
|
||
|
||
|
||
sle2EthCfmLmmStatusEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmLmmStatusEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
|
||
::= { sle2EthCfmLmmStatusTable 1 }
|
||
|
||
|
||
Sle2EthCfmLmmStatusEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmLmmStatusRmepId
|
||
Integer32,
|
||
sle2EthCfmLmmStatusStartTime
|
||
TimeTicks,
|
||
sle2EthCfmLmmStatusCurrentTime
|
||
TimeTicks,
|
||
sle2EthCfmLmmStatusEndTime
|
||
TimeTicks,
|
||
sle2EthCfmLmmStatusNeerLoss
|
||
Integer32,
|
||
sle2EthCfmLmmStatusFarLoss
|
||
Integer32,
|
||
sle2EthCfmLmmStatusCurNeerLoss
|
||
Integer32,
|
||
sle2EthCfmLmmStatusCurFarLoss
|
||
Integer32
|
||
}
|
||
|
||
sle2EthCfmLmmStatusRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 1 }
|
||
|
||
|
||
sle2EthCfmLmmStatusStartTime OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 2 }
|
||
|
||
|
||
sle2EthCfmLmmStatusCurrentTime OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 3 }
|
||
|
||
|
||
sle2EthCfmLmmStatusEndTime OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 4 }
|
||
|
||
|
||
sle2EthCfmLmmStatusNeerLoss OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 5 }
|
||
|
||
|
||
sle2EthCfmLmmStatusFarLoss OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 6 }
|
||
|
||
|
||
sle2EthCfmLmmStatusCurNeerLoss OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 7 }
|
||
|
||
|
||
sle2EthCfmLmmStatusCurFarLoss OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmLmmStatusEntry 8 }
|
||
|
||
|
||
sle2EthernetCfmRmep OBJECT IDENTIFIER ::= { sle2EthernetCfm 13 }
|
||
|
||
|
||
sle2EthCfmRmepTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmRmepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmRmep 1 }
|
||
|
||
|
||
sle2EthCfmRmepEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmRmepEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmRmepId }
|
||
::= { sle2EthCfmRmepTable 1 }
|
||
|
||
|
||
Sle2EthCfmRmepEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmRmepId
|
||
Integer32,
|
||
sle2EthCfmRempMepId
|
||
Integer32,
|
||
sle2EthCfmRmepLevel
|
||
Integer32,
|
||
sle2EthCfmRmepMaVid
|
||
Integer32,
|
||
sle2EthCfmRmepActiveState
|
||
INTEGER,
|
||
sle2EthCfmRmepRemoteMac
|
||
OCTET STRING,
|
||
sle2EthCfmRmepRdi
|
||
INTEGER,
|
||
sle2EthCfmRmepFlags
|
||
INTEGER
|
||
}
|
||
|
||
sle2EthCfmRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates mepid of remote."
|
||
::= { sle2EthCfmRmepEntry 1 }
|
||
|
||
|
||
sle2EthCfmRempMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmRmepEntry 2 }
|
||
|
||
|
||
sle2EthCfmRmepLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maintenance domain level."
|
||
::= { sle2EthCfmRmepEntry 3 }
|
||
|
||
|
||
sle2EthCfmRmepMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (0..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The VLAN Identifier.
|
||
0: default Ma vid
|
||
"
|
||
::= { sle2EthCfmRmepEntry 4 }
|
||
|
||
|
||
sle2EthCfmRmepActiveState OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates active status."
|
||
::= { sle2EthCfmRmepEntry 5 }
|
||
|
||
|
||
sle2EthCfmRmepRemoteMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the remote mac address."
|
||
::= { sle2EthCfmRmepEntry 6 }
|
||
|
||
|
||
sle2EthCfmRmepRdi OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
false(0),
|
||
true(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the RDI flags."
|
||
::= { sle2EthCfmRmepEntry 7 }
|
||
|
||
|
||
sle2EthCfmRmepFlags OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
configured(1),
|
||
configuredLearnt(2),
|
||
learnt(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates configure status"
|
||
::= { sle2EthCfmRmepEntry 8 }
|
||
|
||
|
||
sle2EthCfmRmepControl OBJECT IDENTIFIER ::= { sle2EthernetCfmRmep 2 }
|
||
|
||
|
||
sle2EthCfmRmepControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clearRmepDomain(1),
|
||
clearRmepLevel(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The request of a user command"
|
||
::= { sle2EthCfmRmepControl 1 }
|
||
|
||
|
||
sle2EthCfmRmepControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of user command"
|
||
::= { sle2EthCfmRmepControl 2 }
|
||
|
||
|
||
sle2EthCfmRmepControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum time for the manager for a long running user command"
|
||
::= { sle2EthCfmRmepControl 3 }
|
||
|
||
|
||
sle2EthCfmRmepControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time stamp of the last command(end of command)"
|
||
::= { sle2EthCfmRmepControl 4 }
|
||
|
||
|
||
sle2EthCfmRmepControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result of the last command."
|
||
::= { sle2EthCfmRmepControl 5 }
|
||
|
||
|
||
sle2EthCfmRmepControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates bridgegroup id
|
||
1: default bridge id
|
||
"
|
||
::= { sle2EthCfmRmepControl 6 }
|
||
|
||
|
||
sle2EthCfmRmepControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maintenance domain name."
|
||
::= { sle2EthCfmRmepControl 7 }
|
||
|
||
|
||
sle2EthCfmRmepControlMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maintenance domain level."
|
||
::= { sle2EthCfmRmepControl 8 }
|
||
|
||
|
||
sle2EthCfmRmepNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmRmep 3 }
|
||
|
||
|
||
sle2EthCfmRmepDomainCleared NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"clearRmepDomain"
|
||
::= { sle2EthCfmRmepNotification 1 }
|
||
|
||
|
||
sle2EthCfmRmepLevelCleared NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdLevel
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"clearRmepLevel"
|
||
::= { sle2EthCfmRmepNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmMip OBJECT IDENTIFIER ::= { sle2EthernetCfm 14 }
|
||
|
||
|
||
sle2EthCfmMipTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmMipEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmMip 1 }
|
||
|
||
|
||
sle2EthCfmMipEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmMipEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMipVid, sle2EthCfmMipMdLevel, sle2EthCfmMipIfindex }
|
||
::= { sle2EthCfmMipTable 1 }
|
||
|
||
|
||
Sle2EthCfmMipEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmMipVid
|
||
Integer32,
|
||
sle2EthCfmMipMdLevel
|
||
Integer32,
|
||
sle2EthCfmMipIfindex
|
||
Integer32,
|
||
sle2EthCfmMipLocalMac
|
||
OCTET STRING
|
||
}
|
||
|
||
sle2EthCfmMipVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthCfmMipEntry 1 }
|
||
|
||
|
||
sle2EthCfmMipMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the maintenance domain level."
|
||
::= { sle2EthCfmMipEntry 2 }
|
||
|
||
|
||
sle2EthCfmMipIfindex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indcates the port interface index."
|
||
::= { sle2EthCfmMipEntry 3 }
|
||
|
||
|
||
sle2EthCfmMipLocalMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The mac address of local mep."
|
||
::= { sle2EthCfmMipEntry 4 }
|
||
|
||
|
||
sle2EthernetCfmStatistics OBJECT IDENTIFIER ::= { sle2EthernetCfm 15 }
|
||
|
||
|
||
sle2EthCfmStatisticsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmStatisticsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmStatistics 1 }
|
||
|
||
|
||
sle2EthCfmStatisticsEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmStatisticsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
|
||
::= { sle2EthCfmStatisticsTable 1 }
|
||
|
||
|
||
Sle2EthCfmStatisticsEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmStatCcmSent
|
||
Gauge32,
|
||
sle2EthCfmStatCcmRevOutOfSeq
|
||
Gauge32,
|
||
sle2EthCfmStatLbrSent
|
||
Gauge32,
|
||
sle2EthCfmStatLbrRevValid
|
||
Gauge32,
|
||
sle2EthCfmStatLbrRevBadMsdu
|
||
Gauge32,
|
||
sle2EthCfmStatLbrRevOutOfSeq
|
||
Gauge32,
|
||
sle2EthCfmStatLtrRevUnexpected
|
||
Counter32
|
||
}
|
||
|
||
sle2EthCfmStatCcmSent OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the ccm packet number."
|
||
::= { sle2EthCfmStatisticsEntry 1 }
|
||
|
||
|
||
sle2EthCfmStatCcmRevOutOfSeq OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the received out of sequence number."
|
||
::= { sle2EthCfmStatisticsEntry 2 }
|
||
|
||
|
||
sle2EthCfmStatLbrSent OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the lbr packet number."
|
||
::= { sle2EthCfmStatisticsEntry 3 }
|
||
|
||
|
||
sle2EthCfmStatLbrRevValid OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the valid lbr packet number."
|
||
::= { sle2EthCfmStatisticsEntry 4 }
|
||
|
||
|
||
sle2EthCfmStatLbrRevBadMsdu OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the bad lbr packet number."
|
||
::= { sle2EthCfmStatisticsEntry 5 }
|
||
|
||
|
||
sle2EthCfmStatLbrRevOutOfSeq OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the received out of sequence number."
|
||
::= { sle2EthCfmStatisticsEntry 6 }
|
||
|
||
|
||
sle2EthCfmStatLtrRevUnexpected OBJECT-TYPE
|
||
SYNTAX Counter32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the unexected received lbr packet number."
|
||
::= { sle2EthCfmStatisticsEntry 7 }
|
||
|
||
|
||
sle2EthernetCfmActiveLevel OBJECT IDENTIFIER ::= { sle2EthernetCfm 16 }
|
||
|
||
|
||
sle2EthCfmActiveLevelTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmActiveLevelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmActiveLevel 1 }
|
||
|
||
|
||
sle2EthCfmActiveLevelEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmActiveLevelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMaVid, sle2EthCfmAcitveLevelIfIndex }
|
||
::= { sle2EthCfmActiveLevelTable 1 }
|
||
|
||
|
||
Sle2EthCfmActiveLevelEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmAcitveLevelIfIndex
|
||
Integer32,
|
||
sle2EthCfmActiveLevelStatus
|
||
BITS
|
||
}
|
||
|
||
sle2EthCfmAcitveLevelIfIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The interface index."
|
||
::= { sle2EthCfmActiveLevelEntry 1 }
|
||
|
||
|
||
sle2EthCfmActiveLevelStatus OBJECT-TYPE
|
||
SYNTAX BITS
|
||
{
|
||
level7(0),
|
||
level6(1),
|
||
level5(2),
|
||
level4(3),
|
||
level3(4),
|
||
level2(5),
|
||
level1(6),
|
||
level0(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates status of active level
|
||
|
||
"
|
||
::= { sle2EthCfmActiveLevelEntry 2 }
|
||
|
||
|
||
sle2EthernetCfmError OBJECT IDENTIFIER ::= { sle2EthernetCfm 17 }
|
||
|
||
|
||
sle2EthCfmErrorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmErrorEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmError 1 }
|
||
|
||
|
||
sle2EthCfmErrorEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmErrorEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmErrorIndex }
|
||
::= { sle2EthCfmErrorTable 1 }
|
||
|
||
|
||
Sle2EthCfmErrorEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmErrorIndex
|
||
Integer32,
|
||
sle2EthCfmErrorMdLevel
|
||
Integer32,
|
||
sle2EthCfmErrorMaVid
|
||
Integer32,
|
||
sle2EthCfmErrorMepId
|
||
Integer32,
|
||
sle2EthCfmErrorRmepMac
|
||
OCTET STRING,
|
||
sle2EthCfmErrorReason
|
||
INTEGER,
|
||
sle2EthCfmErrorServiceId
|
||
OCTET STRING
|
||
}
|
||
|
||
sle2EthCfmErrorIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the error index."
|
||
::= { sle2EthCfmErrorEntry 1 }
|
||
|
||
|
||
sle2EthCfmErrorMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates level of MD."
|
||
::= { sle2EthCfmErrorEntry 2 }
|
||
|
||
|
||
sle2EthCfmErrorMaVid OBJECT-TYPE
|
||
SYNTAX Integer32 (0..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The VLAN Identifier.
|
||
0: default Ma vid
|
||
"
|
||
::= { sle2EthCfmErrorEntry 3 }
|
||
|
||
|
||
sle2EthCfmErrorMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The MA end point ID."
|
||
::= { sle2EthCfmErrorEntry 4 }
|
||
|
||
|
||
sle2EthCfmErrorRmepMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates mac address of remote mep "
|
||
::= { sle2EthCfmErrorEntry 5 }
|
||
|
||
|
||
sle2EthCfmErrorReason OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
rmepDown(0),
|
||
confError(1),
|
||
fowardLoop(2),
|
||
crossConnect(3),
|
||
missingRmep(4),
|
||
unknownMep(5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates error reason."
|
||
::= { sle2EthCfmErrorEntry 6 }
|
||
|
||
|
||
sle2EthCfmErrorServiceId OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maintenance association name."
|
||
::= { sle2EthCfmErrorEntry 7 }
|
||
|
||
|
||
sle2EthCfmErrorControl OBJECT IDENTIFIER ::= { sle2EthernetCfmError 2 }
|
||
|
||
|
||
sle2EthCfmErrorControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clearCfmErrorDomain(1),
|
||
clearCfmErrorLevel(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The request of a user command"
|
||
::= { sle2EthCfmErrorControl 1 }
|
||
|
||
|
||
sle2EthCfmErrorControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of user command"
|
||
::= { sle2EthCfmErrorControl 2 }
|
||
|
||
|
||
sle2EthCfmErrorControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum time for the manager for a long running user command"
|
||
::= { sle2EthCfmErrorControl 3 }
|
||
|
||
|
||
sle2EthCfmErrorControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time stamp of the last command(end of command)"
|
||
::= { sle2EthCfmErrorControl 4 }
|
||
|
||
|
||
sle2EthCfmErrorControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result of the last command."
|
||
::= { sle2EthCfmErrorControl 5 }
|
||
|
||
|
||
sle2EthCfmErrorControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates bridgegroup id
|
||
1: default bridge id
|
||
"
|
||
::= { sle2EthCfmErrorControl 6 }
|
||
|
||
|
||
sle2EthCfmErrorControlMdName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maintenance domain name."
|
||
::= { sle2EthCfmErrorControl 7 }
|
||
|
||
|
||
sle2EthCfmErrorControlMdLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates level of MD."
|
||
::= { sle2EthCfmErrorControl 8 }
|
||
|
||
|
||
sle2EthCfmErrorNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmError 3 }
|
||
|
||
|
||
sle2EthCfmErrorDomainCleared NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"clearCfmErrorDomain"
|
||
::= { sle2EthCfmErrorNotification 1 }
|
||
|
||
|
||
sle2EthCfmErrorLevelCleared NOTIFICATION-TYPE
|
||
OBJECTS { sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmErrorMdLevel
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"clearCfmErrorLevel"
|
||
::= { sle2EthCfmErrorNotification 2 }
|
||
|
||
|
||
sle2EthernetCfmLtCache OBJECT IDENTIFIER ::= { sle2EthernetCfm 18 }
|
||
|
||
|
||
sle2EthCfmLtCacheTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2EthCfmLtCacheEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2EthernetCfmLtCache 1 }
|
||
|
||
|
||
sle2EthCfmLtCacheEntry OBJECT-TYPE
|
||
SYNTAX Sle2EthCfmLtCacheEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2EthCfmBridgeId, sle2EthCfmLtCacheIndex }
|
||
::= { sle2EthCfmLtCacheTable 1 }
|
||
|
||
|
||
Sle2EthCfmLtCacheEntry ::=
|
||
SEQUENCE {
|
||
sle2EthCfmLtCacheIndex
|
||
Integer32,
|
||
sle2EthCfmLtCacheSrcMac
|
||
OCTET STRING,
|
||
sle2EthCfmLtCacheHops
|
||
Integer32,
|
||
sle2EthCfmLtCacheRelay
|
||
INTEGER
|
||
}
|
||
|
||
sle2EthCfmLtCacheIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the linktrace cache index."
|
||
::= { sle2EthCfmLtCacheEntry 1 }
|
||
|
||
|
||
sle2EthCfmLtCacheSrcMac OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates MAC address.
|
||
(SIZE (6))"
|
||
::= { sle2EthCfmLtCacheEntry 2 }
|
||
|
||
|
||
sle2EthCfmLtCacheHops OBJECT-TYPE
|
||
SYNTAX Integer32 (1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates TTL field value for a returned LTR."
|
||
::= { sle2EthCfmLtCacheEntry 3 }
|
||
|
||
|
||
sle2EthCfmLtCacheRelay OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
unknown(0),
|
||
rlyHit(1),
|
||
rlyFDB(2),
|
||
rlyMPDB(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the value returned in the Relay Action field"
|
||
::= { sle2EthCfmLtCacheEntry 4 }
|
||
|
||
|
||
sle2Erps OBJECT IDENTIFIER ::= { sleFaultMgmt 18 }
|
||
|
||
|
||
sle2ErpsPhyRing OBJECT IDENTIFIER ::= { sle2Erps 1 }
|
||
|
||
|
||
sle2ErpsPhyRingTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2ErpsPhyRingEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsPhyRing 1 }
|
||
|
||
|
||
sle2ErpsPhyRingEntry OBJECT-TYPE
|
||
SYNTAX Sle2ErpsPhyRingEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName }
|
||
::= { sle2ErpsPhyRingTable 1 }
|
||
|
||
|
||
Sle2ErpsPhyRingEntry ::=
|
||
SEQUENCE {
|
||
sle2ErpsPhyRingBridgeId
|
||
Integer32,
|
||
sle2ErpsPhyRingName
|
||
OCTET STRING,
|
||
sle2ErpsPhyRingEastPort
|
||
Integer32,
|
||
sle2ErpsPhyRingEastMepId
|
||
Integer32,
|
||
sle2ErpsPhyRingEastRmepId
|
||
Integer32,
|
||
sle2ErpsPhyRingWestPort
|
||
Integer32,
|
||
sle2ErpsPhyRingWestMepId
|
||
Integer32,
|
||
sle2ErpsPhyRingWestRmepId
|
||
Integer32
|
||
}
|
||
|
||
sle2ErpsPhyRingBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates primary bridgegroup id
|
||
1: default bridge id
|
||
100: backbone"
|
||
::= { sle2ErpsPhyRingEntry 1 }
|
||
|
||
|
||
sle2ErpsPhyRingName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Physical ring name (maximum 37 characters)."
|
||
::= { sle2ErpsPhyRingEntry 2 }
|
||
|
||
|
||
sle2ErpsPhyRingEastPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s east port(ifindex)"
|
||
::= { sle2ErpsPhyRingEntry 3 }
|
||
|
||
|
||
sle2ErpsPhyRingEastMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsPhyRingEntry 4 }
|
||
|
||
|
||
sle2ErpsPhyRingEastRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsPhyRingEntry 5 }
|
||
|
||
|
||
sle2ErpsPhyRingWestPort OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s west port(ifindex)"
|
||
::= { sle2ErpsPhyRingEntry 6 }
|
||
|
||
|
||
sle2ErpsPhyRingWestMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsPhyRingEntry 7 }
|
||
|
||
|
||
sle2ErpsPhyRingWestRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsPhyRingEntry 8 }
|
||
|
||
|
||
sle2ErpsPhyRingControl OBJECT IDENTIFIER ::= { sle2ErpsPhyRing 2 }
|
||
|
||
|
||
sle2ErpsPhyRingControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createPhyRing(1),
|
||
destoryPhyRing(2),
|
||
addEastPort(3),
|
||
delEastPort(4),
|
||
addWestPort(5),
|
||
delWestPort(6),
|
||
addEastPortMepId(7),
|
||
delEastPortMepId(8),
|
||
addWestPortMepId(9),
|
||
delWestPortMepId(10)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The request of a user command"
|
||
::= { sle2ErpsPhyRingControl 1 }
|
||
|
||
|
||
sle2ErpsPhyRingControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of user command"
|
||
::= { sle2ErpsPhyRingControl 2 }
|
||
|
||
|
||
sle2ErpsPhyRingControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum time for the manager for a long running user command"
|
||
::= { sle2ErpsPhyRingControl 3 }
|
||
|
||
|
||
sle2ErpsPhyRingControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time stamp of the last command(end of command)"
|
||
::= { sle2ErpsPhyRingControl 4 }
|
||
|
||
|
||
sle2ErpsPhyRingControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlRequestResultType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result of the last command."
|
||
::= { sle2ErpsPhyRingControl 5 }
|
||
|
||
|
||
sle2ErpsPhyRingControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates primary bridgegroup id
|
||
1: default bridge id
|
||
100: backbone
|
||
"
|
||
::= { sle2ErpsPhyRingControl 6 }
|
||
|
||
|
||
sle2ErpsPhyRingControName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Physical ring name (maximum 37 characters)."
|
||
::= { sle2ErpsPhyRingControl 7 }
|
||
|
||
|
||
sle2ErpsPhyRingControEastPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s east interface index"
|
||
::= { sle2ErpsPhyRingControl 8 }
|
||
|
||
|
||
sle2ErpsPhyRingControWestPort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s west interface index"
|
||
::= { sle2ErpsPhyRingControl 9 }
|
||
|
||
|
||
sle2ErpsPhyRingControlMepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsPhyRingControl 10 }
|
||
|
||
|
||
sle2ErpsPhyRingControlRmepId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..8191)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsPhyRingControl 11 }
|
||
|
||
|
||
sleErpsPhyRingNotification OBJECT IDENTIFIER ::= { sle2ErpsPhyRing 3 }
|
||
|
||
|
||
sle2ErpsPhyRingCreated NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createPhyRing"
|
||
::= { sleErpsPhyRingNotification 1 }
|
||
|
||
|
||
sle2ErpsPhyRingDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destoryPhyRing"
|
||
::= { sleErpsPhyRingNotification 2 }
|
||
|
||
|
||
sle2ErpsPhyRingEastPortAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
|
||
sle2ErpsPhyRingEastPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 3 }
|
||
|
||
|
||
sle2ErpsPhyRingEastPortDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 4 }
|
||
|
||
|
||
sle2ErpsPhyRingWestPortAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
|
||
sle2ErpsPhyRingWestPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 5 }
|
||
|
||
|
||
sle2ErpsPhyRingWestPortDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 6 }
|
||
|
||
|
||
sle2ErpsPhyRingEastMepIdAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
|
||
sle2ErpsPhyRingEastMepId, sle2ErpsPhyRingEastRmepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 7 }
|
||
|
||
|
||
sle2ErpsPhyRingEastMepIdDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 8 }
|
||
|
||
|
||
sle2ErpsPhyRingWestMepIdAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
|
||
sle2ErpsPhyRingWestMepId, sle2ErpsPhyRingWestRmepId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 9 }
|
||
|
||
|
||
sle2ErpsPhyRingWestMepIdDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleErpsPhyRingNotification 10 }
|
||
|
||
|
||
sle2ErpsProfile OBJECT IDENTIFIER ::= { sle2Erps 2 }
|
||
|
||
|
||
sle2ErpsProfileTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2ErpsProfileEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsProfile 1 }
|
||
|
||
|
||
sle2ErpsProfileEntry OBJECT-TYPE
|
||
SYNTAX Sle2ErpsProfileEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2ErpsProfileBridgeId, sle2ErpsProfileName }
|
||
::= { sle2ErpsProfileTable 1 }
|
||
|
||
|
||
Sle2ErpsProfileEntry ::=
|
||
SEQUENCE {
|
||
sle2ErpsProfileBridgeId
|
||
Integer32,
|
||
sle2ErpsProfileName
|
||
OCTET STRING,
|
||
sle2ErpsProfileHoldOffTime
|
||
INTEGER,
|
||
sle2ErpsProfileGuardTime
|
||
INTEGER,
|
||
sle2ErpsProfileWaitToRestore
|
||
INTEGER,
|
||
sle2ErpsProfileNonRevertive
|
||
INTEGER
|
||
}
|
||
|
||
sle2ErpsProfileBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates primary bridgegroup id
|
||
1: default bridge id
|
||
100: backbone
|
||
"
|
||
::= { sle2ErpsProfileEntry 1 }
|
||
|
||
|
||
sle2ErpsProfileName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Profile name (maximum 32 characters)."
|
||
::= { sle2ErpsProfileEntry 2 }
|
||
|
||
|
||
sle2ErpsProfileHoldOffTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the hold-off time
|
||
default : 0
|
||
"
|
||
DEFVAL { 0 }
|
||
::= { sle2ErpsProfileEntry 3 }
|
||
|
||
|
||
sle2ErpsProfileGuardTime OBJECT-TYPE
|
||
SYNTAX INTEGER (10..2000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the guard time
|
||
default : 500
|
||
"
|
||
DEFVAL { 500 }
|
||
::= { sle2ErpsProfileEntry 4 }
|
||
|
||
|
||
sle2ErpsProfileWaitToRestore OBJECT-TYPE
|
||
SYNTAX INTEGER (1..12)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time
|
||
default : 5
|
||
"
|
||
DEFVAL { 5 }
|
||
::= { sle2ErpsProfileEntry 5 }
|
||
|
||
|
||
sle2ErpsProfileNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
revertive(0),
|
||
nonRevertive(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Non-Revertive or Revertive."
|
||
::= { sle2ErpsProfileEntry 6 }
|
||
|
||
|
||
sle2ErpsProfileControl OBJECT IDENTIFIER ::= { sle2ErpsProfile 2 }
|
||
|
||
|
||
sle2ErpsProfileControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createErpsProfile(1),
|
||
destroyErpsProfile(2),
|
||
setProfileTimer(3),
|
||
setNoneRevertive(4)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The request of a user command"
|
||
::= { sle2ErpsProfileControl 1 }
|
||
|
||
|
||
sle2ErpsProfileControlStatus OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of user command"
|
||
::= { sle2ErpsProfileControl 2 }
|
||
|
||
|
||
sle2ErpsProfileControlTimer OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum time for the manager for a long running user command"
|
||
::= { sle2ErpsProfileControl 3 }
|
||
|
||
|
||
sle2ErpsProfileControlTimeStamp OBJECT-TYPE
|
||
SYNTAX TimeTicks
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The time stamp of the last command(end of command)"
|
||
::= { sle2ErpsProfileControl 4 }
|
||
|
||
|
||
sle2ErpsProfileControlReqResult OBJECT-TYPE
|
||
SYNTAX SleControlStatusType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result of the last command."
|
||
::= { sle2ErpsProfileControl 5 }
|
||
|
||
|
||
sle2ErpsProfileControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates primary bridgegroup id
|
||
1: default bridge id
|
||
100: backbone
|
||
"
|
||
::= { sle2ErpsProfileControl 6 }
|
||
|
||
|
||
sle2ErpsProfileControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Profile name (maximum 32 characters)."
|
||
::= { sle2ErpsProfileControl 7 }
|
||
|
||
|
||
sle2ErpsProfileControlHoldOffTime OBJECT-TYPE
|
||
SYNTAX INTEGER (0..10000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the hold-off time
|
||
default : 0
|
||
"
|
||
DEFVAL { 0 }
|
||
::= { sle2ErpsProfileControl 8 }
|
||
|
||
|
||
sle2ErpsProfileControlGuardTime OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the guard time
|
||
default : 500
|
||
"
|
||
DEFVAL { 500 }
|
||
::= { sle2ErpsProfileControl 9 }
|
||
|
||
|
||
sle2ErpsProfileControlWaitToRestore OBJECT-TYPE
|
||
SYNTAX Integer32 (1..12)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the wait-to-restore time
|
||
default : 5
|
||
"
|
||
DEFVAL { 5 }
|
||
::= { sle2ErpsProfileControl 10 }
|
||
|
||
|
||
sle2ErpsProfileControlNonRevertive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
revertive(0),
|
||
nonRevertive(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Non-Revertive or Revertive."
|
||
::= { sle2ErpsProfileControl 11 }
|
||
|
||
|
||
sle2ErpsProfileNotification OBJECT IDENTIFIER ::= { sle2ErpsProfile 3 }
|
||
|
||
|
||
sle2ErpsProfileCreated NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createErpsProfile"
|
||
::= { sle2ErpsProfileNotification 1 }
|
||
|
||
|
||
sle2ErpsProfileDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileControlBridgeId, sle2ErpsProfileControlName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destoryPhyRing"
|
||
::= { sle2ErpsProfileNotification 2 }
|
||
|
||
|
||
sle2ErpsProfileTimerChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName,
|
||
sle2ErpsProfileHoldOffTime, sle2ErpsProfileGuardTime, sle2ErpsProfileWaitToRestore }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setProfileTimer"
|
||
::= { sle2ErpsProfileNotification 3 }
|
||
|
||
|
||
sle2ErpsProfileNoneRevertiveChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName,
|
||
sle2ErpsProfileNonRevertive }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setNoneRevertive"
|
||
::= { sle2ErpsProfileNotification 4 }
|
||
|
||
|
||
sle2ErpsInstance OBJECT IDENTIFIER ::= { sle2Erps 3 }
|
||
|
||
|
||
sle2ErpsInstanceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF Sle2ErpsInstanceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstance 1 }
|
||
|
||
|
||
sle2ErpsInstanceEntry OBJECT-TYPE
|
||
SYNTAX Sle2ErpsInstanceEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
INDEX { sle2ErpsInstBridgeId, sle2ErpsInstName }
|
||
::= { sle2ErpsInstanceTable 1 }
|
||
|
||
|
||
Sle2ErpsInstanceEntry ::=
|
||
SEQUENCE {
|
||
sle2ErpsInstBridgeId
|
||
Integer32,
|
||
sle2ErpsInstName
|
||
OCTET STRING,
|
||
sle2ErpsInstPhyRingName
|
||
OCTET STRING,
|
||
sle2ErpsInstProfileName
|
||
OCTET STRING,
|
||
sle2ErpsInstRingId
|
||
Integer32,
|
||
sle2ErpsInstLevel
|
||
Integer32,
|
||
sle2ErpsInstRplRole
|
||
INTEGER,
|
||
sle2ErpsInstRplRolePort
|
||
INTEGER,
|
||
sle2ErpsInstSubRingBlock
|
||
INTEGER,
|
||
sle2ErpsInstCtrlVlan
|
||
Integer32,
|
||
sle2ErpsInstTafficVlans
|
||
OCTET STRING,
|
||
sle2ErpsInstChannelMode
|
||
INTEGER,
|
||
sle2ErpsInstVChannelVid
|
||
Integer32,
|
||
sle2ErpsInstVChannelAttachInstName
|
||
OCTET STRING,
|
||
sle2ErpsInstPropagateTc
|
||
INTEGER,
|
||
sle2ErpsInstActive
|
||
INTEGER,
|
||
sle2ErpsInstStatus
|
||
INTEGER,
|
||
sle2ErpsInstEastIfindex
|
||
Integer32,
|
||
sle2ErpsInstEastPortStatus
|
||
INTEGER,
|
||
sle2ErpsInstWestIfindex
|
||
Integer32,
|
||
sle2ErpsInstWestPortStatus
|
||
INTEGER,
|
||
sle2ErpsInstVersion
|
||
INTEGER,
|
||
sle2ErpsInstDataTrafficInheritanceInstName
|
||
OCTET STRING
|
||
}
|
||
|
||
sle2ErpsInstBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates primary bridgegroup id
|
||
1: default bridge id
|
||
100: backbone
|
||
"
|
||
::= { sle2ErpsInstanceEntry 1 }
|
||
|
||
|
||
sle2ErpsInstName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The ERPS instance name."
|
||
::= { sle2ErpsInstanceEntry 2 }
|
||
|
||
|
||
sle2ErpsInstPhyRingName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Physical ring name (maximum 37 characters).
|
||
Indicates the sle2ErpsPhyRingName of sle2ErpsPhyRing table
|
||
"
|
||
::= { sle2ErpsInstanceEntry 3 }
|
||
|
||
|
||
sle2ErpsInstProfileName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Profile name (maximum 32 characters).
|
||
Indicates the sle2ErpsProfileName of sle2ErpsProfile Table.
|
||
"
|
||
::= { sle2ErpsInstanceEntry 4 }
|
||
|
||
|
||
sle2ErpsInstRingId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E>s ID"
|
||
::= { sle2ErpsInstanceEntry 5 }
|
||
|
||
|
||
sle2ErpsInstLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E>s Level"
|
||
::= { sle2ErpsInstanceEntry 6 }
|
||
|
||
|
||
sle2ErpsInstRplRole OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
owner(1),
|
||
neighbour(2),
|
||
nextNeighbor(3)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s Role"
|
||
::= { sle2ErpsInstanceEntry 7 }
|
||
|
||
|
||
sle2ErpsInstRplRolePort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E>s RPL port"
|
||
::= { sle2ErpsInstanceEntry 8 }
|
||
|
||
|
||
sle2ErpsInstSubRingBlock OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Sub-Ring<6E>s RPL port.
|
||
Indicates the Ring<6E>s interconnection port.
|
||
You should only give this command on interconnection nodes.
|
||
"
|
||
::= { sle2ErpsInstanceEntry 9 }
|
||
|
||
|
||
sle2ErpsInstCtrlVlan OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s control-vlan"
|
||
::= { sle2ErpsInstanceEntry 10 }
|
||
|
||
|
||
sle2ErpsInstTafficVlans OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s traffic-vlans"
|
||
::= { sle2ErpsInstanceEntry 11 }
|
||
|
||
|
||
sle2ErpsInstChannelMode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
nonVirtualChannel(1),
|
||
virtualChannel(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceEntry 12 }
|
||
|
||
|
||
sle2ErpsInstVChannelVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"VLAN identifier"
|
||
::= { sle2ErpsInstanceEntry 13 }
|
||
|
||
|
||
sle2ErpsInstVChannelAttachInstName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Major instance name."
|
||
::= { sle2ErpsInstanceEntry 14 }
|
||
|
||
|
||
sle2ErpsInstPropagateTc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceEntry 15 }
|
||
|
||
|
||
sle2ErpsInstActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceEntry 16 }
|
||
|
||
|
||
sle2ErpsInstStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
init(1),
|
||
pending(2),
|
||
idle(3),
|
||
foreced(4),
|
||
protected(5),
|
||
manual(6)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the erps instance status."
|
||
::= { sle2ErpsInstanceEntry 17 }
|
||
|
||
|
||
sle2ErpsInstEastIfindex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceEntry 18 }
|
||
|
||
|
||
sle2ErpsInstEastPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
unblocked(1),
|
||
blocked(2),
|
||
failed(3),
|
||
blockedFailed(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the east interface status."
|
||
::= { sle2ErpsInstanceEntry 19 }
|
||
|
||
|
||
sle2ErpsInstWestIfindex OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceEntry 20 }
|
||
|
||
|
||
sle2ErpsInstWestPortStatus OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
unblocked(1),
|
||
blocked(2),
|
||
failed(3),
|
||
blockedFailed(4)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the west interface status."
|
||
::= { sle2ErpsInstanceEntry 21 }
|
||
|
||
|
||
sle2ErpsInstVersion OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
version1(1),
|
||
version2(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the west interface erps version.
|
||
Version 1: ITU-T Recommendation G.8032/Y.1344 2008
|
||
Version 2: ITU-T Recommendation G.8032/Y.1344 2008
|
||
"
|
||
::= { sle2ErpsInstanceEntry 22 }
|
||
|
||
|
||
sle2ErpsInstDataTrafficInheritanceInstName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The inheritance ERPS instance name. (temporary)"
|
||
::= { sle2ErpsInstanceEntry 23 }
|
||
|
||
|
||
sle2ErpsInstanceControl OBJECT IDENTIFIER ::= { sle2ErpsInstance 2 }
|
||
|
||
|
||
sle2ErpsInstControlRequest OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
createErpsInstance(1),
|
||
destoryErpsInstance(2),
|
||
addErpsInstPhyRing(3),
|
||
delErpsInstPhyRing(4),
|
||
addErpsInstProfile(5),
|
||
delErpsInstProfile(6),
|
||
setErpsInstRingId(7),
|
||
setErpsInstLevel(8),
|
||
setErpsInstRpl(9),
|
||
addErpsInstSubRing(10),
|
||
delErpsInstSubRing(11),
|
||
addErpsInstCtrlVlan(12),
|
||
delErpsInstCtrlVlan(13),
|
||
addErpsInstTrafficVlan(14),
|
||
delErpsInstTrafficVlan(15),
|
||
addErpsInstVitrualChannel(16),
|
||
delErpsInstVitrualChannel(17),
|
||
addErpsInstNoneVirtualChanel(18),
|
||
delErpsInstNoneVirtualChanel(19),
|
||
setErpsInstForcedSwitch(20),
|
||
setErpsInstManualSwitch(21),
|
||
clearErpsInst(22),
|
||
setErpsInstPropagateTc(23),
|
||
setErpsInstVersion(24),
|
||
setErpsInstActive(25),
|
||
setVlanInheritanceDataTraffic(26),
|
||
delVlanInheritanceDataTraffic(27)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceControl 1 }
|
||
|
||
|
||
sle2ErpsInstControlStatus OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceControl 2 }
|
||
|
||
|
||
sle2ErpsInstControlTimer OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceControl 3 }
|
||
|
||
|
||
sle2ErpsInstControlTimeStamp OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceControl 4 }
|
||
|
||
|
||
sle2ErpsInstControlReqResult OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceControl 5 }
|
||
|
||
|
||
sle2ErpsInstControlBridgeId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32 | 100)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates primary bridgegroup id
|
||
1: default bridge id
|
||
100: backbone
|
||
"
|
||
::= { sle2ErpsInstanceControl 6 }
|
||
|
||
|
||
sle2ErpsInstControlName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The ERPS instance name."
|
||
::= { sle2ErpsInstanceControl 7 }
|
||
|
||
|
||
sle2ErpsInstControlPhyRingName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Physical ring name (maximum 37 characters).
|
||
Indicates the sle2ErpsPhyRingName of sle2ErpsPhyRing table
|
||
"
|
||
::= { sle2ErpsInstanceControl 8 }
|
||
|
||
|
||
sle2ErpsInstControlProfileName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Profile name (maximum 32 characters).
|
||
Indicates the sle2ErpsProfileName of sle2ErpsProfile Table.
|
||
"
|
||
::= { sle2ErpsInstanceControl 9 }
|
||
|
||
|
||
sle2ErpsInstControlRingId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E>s ID"
|
||
::= { sle2ErpsInstanceControl 10 }
|
||
|
||
|
||
sle2ErpsInstControlLevel OBJECT-TYPE
|
||
SYNTAX Integer32 (0..7)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E>s Level"
|
||
::= { sle2ErpsInstanceControl 11 }
|
||
|
||
|
||
sle2ErpsInstControlRplRole OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
none(0),
|
||
owner(1),
|
||
neighbour(2),
|
||
nextNeighbor(3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s Role"
|
||
::= { sle2ErpsInstanceControl 12 }
|
||
|
||
|
||
sle2ErpsInstControlRplRolePort OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring<6E>s RPL port"
|
||
::= { sle2ErpsInstanceControl 13 }
|
||
|
||
|
||
sle2ErpsInstControlSubRingBlock OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Sub-Ring<6E>s RPL port.
|
||
Indicates the Ring<6E>s interconnection port.
|
||
You should only give this command on interconnection nodes.
|
||
"
|
||
::= { sle2ErpsInstanceControl 14 }
|
||
|
||
|
||
sle2ErpsInstControlCtrlVlan OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node<64>s control-vlan"
|
||
::= { sle2ErpsInstanceControl 15 }
|
||
|
||
|
||
sle2ErpsInstControlTafficVlans OBJECT-TYPE
|
||
SYNTAX Integer32 (2..4092)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Ring Node traffic-vlans"
|
||
::= { sle2ErpsInstanceControl 16 }
|
||
|
||
|
||
sle2ErpsInstControlVChannelVid OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4094)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"VLAN identifier"
|
||
::= { sle2ErpsInstanceControl 17 }
|
||
|
||
|
||
sle2ErpsInstControlVChannelAttachInstName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Major instance name."
|
||
::= { sle2ErpsInstanceControl 18 }
|
||
|
||
|
||
sle2ErpsInstControlForcedSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Forced Switch"
|
||
::= { sle2ErpsInstanceControl 19 }
|
||
|
||
|
||
sle2ErpsInstControlManualSwitch OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
east(1),
|
||
west(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the Manual Switch"
|
||
::= { sle2ErpsInstanceControl 20 }
|
||
|
||
|
||
sle2ErpsInstControlPropagateTc OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceControl 21 }
|
||
|
||
|
||
sle2ErpsInstControlVersion OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
version1(1),
|
||
version2(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicates the version.
|
||
Version 0: ITU-T Recommendation G.8032/Y.1344 2008
|
||
Version 1: ITU-T Recommendation G.8032/Y.1344 2008
|
||
"
|
||
::= { sle2ErpsInstanceControl 22 }
|
||
|
||
|
||
sle2ErpsInstControlActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
disable(0),
|
||
enable(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceControl 23 }
|
||
|
||
|
||
sle2ErpsInstControlDataTrafficInheritanceInstName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The inheritance ERPS instance name. (temporary)"
|
||
::= { sle2ErpsInstanceControl 24 }
|
||
|
||
|
||
sle2ErpsInstanceNotification OBJECT IDENTIFIER ::= { sle2ErpsInstance 3 }
|
||
|
||
|
||
sle2ErpsInstCreated NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"createErpsInstance"
|
||
::= { sle2ErpsInstanceNotification 1 }
|
||
|
||
|
||
sle2ErpsInstDestoryed NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"destoryErpsInstance
|
||
"
|
||
::= { sle2ErpsInstanceNotification 2 }
|
||
|
||
|
||
sle2ErpsInstPhyRingAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstPhyRingName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsPhyRing"
|
||
::= { sle2ErpsInstanceNotification 3 }
|
||
|
||
|
||
sle2ErpsInstPhyRingDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceNotification 4 }
|
||
|
||
|
||
sle2ErpsInstProfileAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstProfileName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsProfile"
|
||
::= { sle2ErpsInstanceNotification 5 }
|
||
|
||
|
||
sle2ErpsInstProfileDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceNotification 6 }
|
||
|
||
|
||
sle2ErpsInstRingIdChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstRingId }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstRingId"
|
||
::= { sle2ErpsInstanceNotification 7 }
|
||
|
||
|
||
sle2ErpsInstLevelChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstLevel }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstLevel"
|
||
::= { sle2ErpsInstanceNotification 8 }
|
||
|
||
|
||
sle2ErpsInstRplRoleChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstRplRole, sle2ErpsInstRplRolePort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstRpl"
|
||
::= { sle2ErpsInstanceNotification 9 }
|
||
|
||
|
||
sle2ErpsInstSubRingAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstSubRingBlock }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"addErpsInstRubRing"
|
||
::= { sle2ErpsInstanceNotification 10 }
|
||
|
||
|
||
sle2ErpsInstSubRingDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delErpsInstRubRing"
|
||
::= { sle2ErpsInstanceNotification 11 }
|
||
|
||
|
||
sle2ErpsInstCtrlVlanAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstCtrlVlan }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"addErpsInstCtrlVlan"
|
||
::= { sle2ErpsInstanceNotification 12 }
|
||
|
||
|
||
sle2ErpsInstCtrlVlanDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
|
||
sle2ErpsInstControlCtrlVlan }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delErpsInstCtrlVlan"
|
||
::= { sle2ErpsInstanceNotification 13 }
|
||
|
||
|
||
sle2ErpsInstDataTrafficVlanAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstTafficVlans }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"addErpsInstTrafficVlan"
|
||
::= { sle2ErpsInstanceNotification 14 }
|
||
|
||
|
||
sle2ErpsInstDataTrafficVlanDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
|
||
sle2ErpsInstControlTafficVlans }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"delErpsInstTrafficVlan"
|
||
::= { sle2ErpsInstanceNotification 15 }
|
||
|
||
|
||
sle2ErpsInstVitrualChannelAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstVChannelVid, sle2ErpsInstVChannelAttachInstName, sle2ErpsInstChannelMode }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstVitrualChannel"
|
||
::= { sle2ErpsInstanceNotification 16 }
|
||
|
||
|
||
sle2ErpsInstVitrualChannelDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceNotification 17 }
|
||
|
||
|
||
sle2ErpsInstNoneVirtualChannelAdded NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstChannelMode }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstNoneVirtualChanel"
|
||
::= { sle2ErpsInstanceNotification 18 }
|
||
|
||
|
||
sle2ErpsInstNoneVirtualChannelDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceNotification 19 }
|
||
|
||
|
||
sle2ErpsInstForcedSwichChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
|
||
sle2ErpsInstControlForcedSwitch }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstForcedSwitch"
|
||
::= { sle2ErpsInstanceNotification 20 }
|
||
|
||
|
||
sle2ErpsInstManualSwichChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
|
||
sle2ErpsInstControlManualSwitch }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstManualSwitch"
|
||
::= { sle2ErpsInstanceNotification 21 }
|
||
|
||
|
||
sle2ErpsInstClearChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstClear"
|
||
::= { sle2ErpsInstanceNotification 22 }
|
||
|
||
|
||
sle2ErpsInstPropagateTcChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstPropagateTc }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstPropagateTc"
|
||
::= { sle2ErpsInstanceNotification 23 }
|
||
|
||
|
||
sle2ErpInstVersionChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstEastVersion, sle2ErpsInstWestVersion }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"setErpsInstVersion"
|
||
::= { sle2ErpsInstanceNotification 24 }
|
||
|
||
|
||
sle2ErpInstActiveChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstActive }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sle2ErpsInstanceNotification 25 }
|
||
|
||
|
||
sle2ErpInstDataTrafficInheritanceInstNameChanged NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstDataTrafficInheritanceInstName, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId,
|
||
sle2ErpsInstName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Temp"
|
||
::= { sle2ErpsInstanceNotification 26 }
|
||
|
||
|
||
sle2ErpInstDataTrafficInheritanceInstNameDeleted NOTIFICATION-TYPE
|
||
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstDataTrafficInheritanceInstName, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId,
|
||
sle2ErpsInstName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Temp"
|
||
::= { sle2ErpsInstanceNotification 27 }
|
||
|
||
|
||
sleFaultMgmtGroup OBJECT-GROUP
|
||
OBJECTS { sleFaultDefaultSeverity, sleFaultCriteriaSeverity, sleFaultNotifiyActivity, sleFaultControlRequest, sleFaultControlStatus,
|
||
sleFaultControlTimer, sleFaultControlTimeStamp, sleFaultControlReqResult, sleFaultControlDefaultSeverity, sleFaultControlCriteriaSeverity,
|
||
sleFaultControlNotifiyActivity, sleAlarmSeverityIndex, sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlStatus,
|
||
sleAlarmSeverityControlTimer, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult, sleAlarmSeverityControlIndex, sleAlarmSeverityControlValue,
|
||
sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource, sleAlarmSpecificSeverity, sleAlarmSpecificProblem,
|
||
sleAlarmSpecificProblemText, sleAlarmTimeAndDate, sleAlarmHistoryIndex, sleAlarmHistorySpecific, sleAlarmHistorySeverity,
|
||
sleAlarmHistoryText, sleAlarmHistoryTime, sleAlarmHistoryControlRequest, sleAlarmHistoryControlStatus, sleAlarmHistoryControlTimer,
|
||
sleAlarmHistoryControlTimeStamp, sleAlarmHistoryControlReqResult, sleOamPortIndex, sleOamMuxAction, sleOamParAction,
|
||
sleOamAdminState, sleOamMode, sleOamUnidirectionMode, sleOamFunctionsSupported, sleOamPeerStatus,
|
||
sleOamPeerMacAddress, sleOamPeerMode, sleOamPeerFunctionsSupported, sleOamRemLoopback, sleOamControlRequest,
|
||
sleOamControlStatus, sleOamControlTimer, sleOamControlTimeStamp, sleOamControlReqResult, sleOamControlIndex,
|
||
sleOamControlPortAdminState, sleOamControlPortMode, sleOamControlPortUnidirectionMode, sleOamControlPortRemLoopback, sleAdvaFSPOperationMode,
|
||
sleAdvaActiveNetworkInterface, sleAdvaForceNetworkInterface, sleAdvaReportingInterval, sleAdvaNEMIFitted, sleAdvaForceReset,
|
||
sleAdvaManagerAddress, sleAdvaMinRailVoltageThreshold, sleAdvaMaxRailVoltageThreshold, sleAdvaTemperatureThreshold, sleAdvaPartNumber,
|
||
sleAdvaSerialNumber, sleAdvaFirmwareVersion, sleAdvaFPGAVersion, sleAdvaHardwareRevision, sleAdvaCLEICode,
|
||
sleAdvaTemperature, sleAdvaRailVoltage, sleAdvaPSUStates, sleAdvaPSUType, sleAdvaFansFitted,
|
||
sleAdvaFanState, sleAdvaTransmitMode, sleAdvaSystemControlRequest, sleAdvaSystemControlStatus, sleAdvaSystemControlTimer,
|
||
sleAdvaSystemControlTimeStamp, sleAdvaSystemControlReqResult, sleAdvaSystemControlPortIndex, sleAdvaSystemControlFSPOperationMode, sleAdvaSystemControlForceNetworkInterface,
|
||
sleAdvaSystemControlReportingInterval, sleAdvaSystemControlForceReset, sleAdvaSystemControlMinRailVoltageThreshold, sleAdvaSystemControlMaxRailVoltageThreshold, sleAdvaSystemControlTemperatureThreshold,
|
||
sleAdvaSystemControlTransmitMode, sleAdvaRemInstance, sleAdvaOperationalStatus, sleAdvaLineSpeed, sleAdvaMACAddress,
|
||
sleAdvaConnectorType, sleAdvaAutonegiotation, sleAdvaLinkLossForwarding, sleAdvaAdminState, sleAdvaRemoteInterfaceIndex,
|
||
sleAdvaUserDefinedString, sleAdvaRemoteSignalling, sleAdvaConfiguration, sleAdvaLocalTechnologyAbility, sleAdvaAdvertisedTechnologyAbility,
|
||
sleAdvaReceivedTechnologyAbility, sleAdvaLocalSectorAbility, sleAdvaAdvertisedSectorAbility, sleAdvaReceivedSectorAbility, sleAdvaDuplexCapabilities,
|
||
sleAdvaPHYType, sleAdvaPHYTypeList, sleAdvaMIIDetect, sleAdvaPHYState, sleAdvaGoodFramesTransmitted,
|
||
sleAdvaSingleCollisionFrames, sleAdvaMultipleCollisionFrames, sleAdvaGoodFramesReceived, sleAdvaFCSErrors, sleAdvaAlignmentErrors,
|
||
sleAdvaFramesTooLong, sleAdvaBytesTransmitted, sleAdvaBytesReceived, sleAdvaSymbolErrors, sleAdvaGeneralControlRequest,
|
||
sleAdvaGeneralControlStatus, sleAdvaGeneralControlTimer, sleAdvaGeneralControlTimeStamp, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlPortIndex,
|
||
sleAdvaGeneralControlRemInstance, sleAdvaGeneralControlLineSpeed, sleAdvaGeneralControlAutonegiotation, sleAdvaGeneralControlLinkLossForwarding, sleAdvaGeneralControlUserDefinedString,
|
||
sleAdvaGeneralControlAdvertisedTechnologyAbility, sleAdvaGeneralControlAdvertisedSectorAbility, sleAdvaModuleType, sleAdvaModulePartNumber, sleAdvaModuleSerialNumber,
|
||
sleAdvaModuleFirmwareVersion, sleAdvaModuleSoftwareVersion, sleAdvaModuleHardwareRevision, sleAdvaModuleCLEICode, sleAdvaOpticalThresholdLevel,
|
||
sleAdvaLinkLength1, sleAdvaLinkLength2, sleAdvaLinkLength3, sleAdvaLinkLength4, sleAdvaLinkLengthCu,
|
||
sleAdvaWaveLength, sleAdvaLaserBias, sleAdvaTransmitPower, sleAdvaReceivePower, sleAdvaLaserTxTemperature,
|
||
sleAdvaOpticalControlRequest, sleAdvaOpticalControlStatus, sleAdvaOpticalControlTimer, sleAdvaOpticalControlTimeStamp, sleAdvaOpticalControlReqResult,
|
||
sleAdvaOpticalControlPortIndex, sleAdvaOpticalControlRemInstance, sleAdvaOpticalControlThresholdLevel, sleAdvaAdminStatus, sleAdvaMode,
|
||
sleAdvaRemMACAddress, sleAdvaRemConfig, sleAdvaRemPduConfig, sleAdvaLocFlags, sleAdvaRemFlags,
|
||
sleAdvaRemState, sleAdvaRemVendorOUI, sleAdvaRemDeviceNumber, sleAdvaRemVendorVersion, sleAdvaLocErrSymbolPeriodEventConfig,
|
||
sleAdvaLocErrFrameEventConfig, sleAdvaLocErrFramePeriodEventConfig, sleAdvaLocErrFrameSecsSummaryEventConfig, sleAdvaPDUsTx, sleAdvaPDUsRx,
|
||
sleAdvaUnsupportedCodesRx, sleAdvaInfoPDUsTx, sleAdvaInfoPDUsRx, sleAdvaEventNotificationPDUsTx, sleAdvaUniqueEventNotificationPDUsTx,
|
||
sleAdvaDupEventNotificationPDUsTx, sleAdvaLoopbackControlPDUsTx, sleAdvaLoopbackControlPDUsRx, sleAdvaVariableRequestPDUsTx, sleAdvaVariableRequestPDUsRx,
|
||
sleAdvaVariableResponsePDUsTx, sleAdvaVariableResponsePDUsRx, sleAdvaVendorPDUsTx, sleAdvaVendorPDUsRx, sleAdvaRemFramesLostDuetoOAMErr,
|
||
sleAdvaLocErrSymbolPeriodEvent, sleAdvaLocErrFrameSecsEvent, sleAdvaLocErrFramePeriodEvent, sleAdvaLocErrFrameSecsSummaryEvent, sleAdvaRemErrSymbolPeriodEvent,
|
||
sleAdvaRemErrFrameSecsEvent, sleAdvaRemoteErrorFramePeriodEvent, sleAdvaRemoteErrorFrameSecsSummaryEvent, sleAdvaOamControlRequest, sleAdvaOamControlStatus,
|
||
sleAdvaOamControlTimer, sleAdvaOamControlTimeStamp, sleAdvaOamControlReqResult, sleAdvaOamControlPortIndex, sleAdvaOamControlRemInstance,
|
||
sleAdvaOamControlAdminStatus, sleAlarmHistorySeqNum, sleAlarmSpecificSeqNum, sleFaultNextSeqNum, sleAlarmLEDType,
|
||
sleAlarmLEDStatus, sleAlarmLEDLevel, sleAlarmLEDLevelIndex, sleAlarmLEDLevelBlock, sleAlarmLEDControlRequest,
|
||
sleAlarmLEDControlStatus, sleAlarmLEDControlTimer, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType,
|
||
sleAlarmLEDControlLevel, sleAlarmLEDControlBlock, sleAlarmLEDLevelOperStatus, sleY1731Enable, sleY1731TrunkEnable,
|
||
sleY1731LtrCacheHoldTime, sleY1731LtrCacheSize, sleY1731SnmpServerTraps, sleY1731XcheckStartDelay, sleY1731DefaultMegLevel,
|
||
sleY1731DefaultMegMhfCreation, sleY1731PduToCfm, sleY1731DedicatedVlan, sleY1731BaseControlRequest, sleY1731BaseControlStatus,
|
||
sleY1731BaseControlTimer, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlEnable, sleY1731BaseControlTrunkEnable,
|
||
sleY1731BaseControlLtrCacheHoldTime, sleY1731BaseControlLtrCacheSize, sleY1731BaseControlSnmpServerTraps, sleY1731BaseControlXcheckStartDelay, sleY1731BaseControlDefaultMegLevel,
|
||
sleY1731BaseControlDefaultMegMhfCreation, sleY1731BaseControlPduToCfm, sleY1731BaseControlDedicatedVlan, sleY1731MegIndex, sleY1731MegName,
|
||
sleY1731MegLevel, sleY1731MegVid, sleY1731MegMepEnable, sleY1731MegCcEnable, sleY1731MegCcInterval,
|
||
sleY1731MegCcPriority, sleY1731MegCcLossThreshold, sleY1731MegCcHoldTime, sleY1731MegFaultPriority, sleY1731MegFaultKeepTime,
|
||
sleY1731MegFaultClearTime, sleY1731MegXcheckEnable, sleY1731MegAisEnable, sleY1731MegAisTransmitEnable, sleY1731MegAisInterval,
|
||
sleY1731MegAisLevel, sleY1731MegAisPriority, sleY1731MegLckEnable, sleY1731MegLckTransmitEnable, sleY1731MegLckInterval,
|
||
sleY1731MegLckLevel, sleY1731MegLckPriority, sleY1731MegOutOfService, sleY1731MegRapsEnable, sleY1731MegRapsRplOwner,
|
||
sleY1731MegRapsEastPort, sleY1731MegRapsWestPort, sleY1731MegRapsRplPort, sleY1731MegRapsHoldOffTime, sleY1731MegRapsGuardTime,
|
||
sleY1731MegRapsWaitToRestore, sleY1731MegRapsState, sleY1731MegControlRequest, sleY1731MegControlStatus, sleY1731MegControlTimer,
|
||
sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlLevel,
|
||
sleY1731MegControlVid, sleY1731MegControlMepEnable, sleY1731MegControlCcEnable, sleY1731MegControlCcInterval, sleY1731MegControlCcPriority,
|
||
sleY1731MegControlCcLossThreshold, sleY1731MegControlCcHoldTime, sleY1731MegControlFaultPriority, sleY1731MegControlFaultKeepTime, sleY1731MegControlFaultClearTime,
|
||
sleY1731MegControlXcheckEnable, sleY1731MegControlAisEnable, sleY1731MegControlAisTransmitEnable, sleY1731MegControlAisInterval, sleY1731MegControlAisLevel,
|
||
sleY1731MegControlAisPriority, sleY1731MegControlLckEnable, sleY1731MegControlLckTransmitEnable, sleY1731MegControlLckInterval, sleY1731MegControlLckLevel,
|
||
sleY1731MegControlLckPriority, sleY1731MegControlOutOfService, sleY1731MegControlRapsEnable, sleY1731MegControlRapsRplOwner, sleY1731MegControlRapsEastPort,
|
||
sleY1731MegControlRapsWestPort, sleY1731MegControlRapsRplPort, sleY1731MegControlRapsHoldOffTime, sleY1731MegControlRapsGuardTime, sleY1731MegControlRapsWaitToRestore,
|
||
sleY1731MepIdentifier, sleY1731MepIfIndex, sleY1731MepDirection, sleY1731MepEnable, sleY1731MepFngState,
|
||
sleY1731MepCcEnable, sleY1731MepMacAddress, sleY1731MepFaultPriority, sleY1731MepFaultKeepTime, sleY1731MepFaultClearTime,
|
||
sleY1731MepHighestPrDefect, sleY1731MepAisEnable, sleY1731MepAisTransmitEnable, sleY1731MepLckEnable, sleY1731MepLckTransmitEnable,
|
||
sleY1731MepOutOfService, sleY1731MepDlmEnabledRmep, sleY1731MepDefects, sleY1731MepCcmSequenceErrors, sleY1731MepCciSentCcms,
|
||
sleY1731MepNextLbmTransId, sleY1731MepLbrIn, sleY1731MepLbrInOutOfOrder, sleY1731MepTstLbrInBitError, sleY1731MepTstLbrInCrcError,
|
||
sleY1731MepLtmNextSeqNumber, sleY1731MepUnexpLtrIn, sleY1731MepLbrOut, sleY1731MepTmLbrFirstLostId, sleY1731MepTmLbrMaxRate,
|
||
sleY1731MepCcmFrameLossNearMin, sleY1731MepCcmFrameLossNearMax, sleY1731MepCcmFrameLossNearSum, sleY1731MepCcmFrameLossFarMin, sleY1731MepCcmFrameLossFarMax,
|
||
sleY1731MepCcmFrameLossFarSum, sleY1731MepControlRequest, sleY1731MepControlStatus, sleY1731MepControlTimer, sleY1731MepControlTimeStamp,
|
||
sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlIfIndex, sleY1731MepControlDirection,
|
||
sleY1731MepControlEnable, sleY1731MepControlCcEnable, sleY1731MepControlFaultPriority, sleY1731MepControlFaultKeepTime, sleY1731MepControlFaultClearTime,
|
||
sleY1731MepControlAisEnable, sleY1731MepControlAisTransmitEnable, sleY1731MepControlLckEnable, sleY1731MepControlLckTransmitEnable, sleY1731MepControlOutOfService,
|
||
sleY1731MepControlDlmEnabledRmep, sleY1731MepControlTransmitLbmIsUnicast, sleY1731MepControlTransmitLbmDestMacAddress, sleY1731MepControlTransmitLbmDestMepId, sleY1731MepControlTransmitLbmDestIsMepId,
|
||
sleY1731MepControlTransmitLbmCount, sleY1731MepControlTransmitLbmInterval, sleY1731MepControlTransmitLbmTimeout, sleY1731MepControlTransmitLbmPriority, sleY1731MepControlTransmitLbmLength,
|
||
sleY1731MepControlTransmitLtmTargetMacAddress, sleY1731MepControlTransmitLtmTargetMepId, sleY1731MepControlTransmitLtmTargetIsMepId, sleY1731MepControlTransmitLtmFlags, sleY1731MepControlTransmitLtmTtl,
|
||
sleY1731MepControlTransmitLtmPriority, sleY1731MepControlTransmitTstLbmDestMepId, sleY1731MepControlTransmitTstLbmDuration, sleY1731MepControlTransmitTstLbmInterval, sleY1731MepControlTransmitTstLbmTimeout,
|
||
sleY1731MepControlTransmitTstLbmPriority, sleY1731MepControlTransmitTstLbmLength, sleY1731MepControlTransmitTstLbmPattern, sleY1731MepControlTransmitTmLbmDestMepId, sleY1731MepControlTransmitTmLbmDuration,
|
||
sleY1731MepControlTransmitTmLbmPartDuration, sleY1731MepControlTransmitTmLbmStartRate, sleY1731MepControlTransmitTmLbmIncRate, sleY1731MepControlTransmitTmLbmTimeout, sleY1731MepControlTransmitTmLbmPriority,
|
||
sleY1731MepControlTransmitTmLbmLength, sleY1731MepControlTransmitTmLbmPattern, sleY1731MepControlTransmitTstIsUnicast, sleY1731MepControlTransmitTstDestMepId, sleY1731MepControlTransmitTstDuration,
|
||
sleY1731MepControlTransmitTstInterval, sleY1731MepControlTransmitTstPriority, sleY1731MepControlTransmitTstLength, sleY1731MepControlTransmitTstPattern, sleY1731MepControlReceiveTstDuration,
|
||
sleY1731MepControlTransmitTmTstIsUnicast, sleY1731MepControlTransmitTmTstDestMepId, sleY1731MepControlTransmitTmTstDuration, sleY1731MepControlTransmitTmTstPartDuration, sleY1731MepControlTransmitTmTstStartRate,
|
||
sleY1731MepControlTransmitTmTstIncRate, sleY1731MepControlTransmitTmTstTimeout, sleY1731MepControlTransmitTmTstPriority, sleY1731MepControlTransmitTmTstLength, sleY1731MepControlTransmitTmTstPattern,
|
||
sleY1731MepControlReceiveTmTstDuration, sleY1731MepControlTransmitLmmIsUnicast, sleY1731MepControlTransmitLmmDestMepId, sleY1731MepControlTransmitLmmDuration, sleY1731MepControlTransmitLmmInterval,
|
||
sleY1731MepControlTransmitLmmTimeout, sleY1731MepControlTransmitLmmPriority, sleY1731MepControlTransmit1dmIsUnicast, sleY1731MepControlTransmit1dmDestMepId, sleY1731MepControlTransmit1dmDuration,
|
||
sleY1731MepControlTransmit1dmInterval, sleY1731MepControlTransmit1dmPriority, sleY1731MepControlReceive1dmDuration, sleY1731MepControlTransmitDmmIsUnicast, sleY1731MepControlTransmitDmmDestMepId,
|
||
sleY1731MepControlTransmitDmmDuration, sleY1731MepControlTransmitDmmInterval, sleY1731MepControlTransmitDmmTimeout, sleY1731MepControlTransmitDmmPriority, sleY1731MipPort,
|
||
sleY1731MipLevel, sleY1731MipType, sleY1731MipControlRequest, sleY1731MipControlStatus, sleY1731MipControlTimer,
|
||
sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort, sleY1731MipControlLevel, sleY1731XcheckMepIdentifier,
|
||
sleY1731XcheckMepState, sleY1731XcheckControlRequest, sleY1731XcheckControlStatus, sleY1731XcheckControlTimer, sleY1731XcheckControlTimeStamp,
|
||
sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex, sleY1731CcMacAddress, sleY1731CcMacControlRequest,
|
||
sleY1731CcMacControlStatus, sleY1731CcMacControlTimer, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex,
|
||
sleY1731CcMacControlMepIdentifier, sleY1731CcMacControlAddress, sleY1731AisMacAddress, sleY1731AisMacControlRequest, sleY1731AisMacControlStatus,
|
||
sleY1731AisMacControlTimer, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier,
|
||
sleY1731AisMacControlAddress, sleY1731LckMacAddress, sleY1731LckMacControlRequest, sleY1731LckMacControlStatus, sleY1731LckMacControlTimer,
|
||
sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier, sleY1731LckMacControlAddress,
|
||
sleY1731RmepIdentifier, sleY1731RmepState, sleY1731RmepFailedOkTime, sleY1731RmepMacAddress, sleY1731RmepIfIndex,
|
||
sleY1731RmepRdi, sleY1731RmepLoc, sleY1731RmepReceiveTstCount, sleY1731RmepReceiveTstOutOfOrder, sleY1731RmepReceiveTstBitError,
|
||
sleY1731RmepReceiveTstCrcError, sleY1731RmepReceiveTmTstCount, sleY1731RmepReceiveTmTstLostId, sleY1731RmepLmrFrameLossNearMin, sleY1731RmepLmrFrameLossNearMax,
|
||
sleY1731RmepLmrFrameLossNearSum, sleY1731RmepLmrFrameLossFarMin, sleY1731RmepLmrFrameLossFarMax, sleY1731RmepLmrFrameLossFarSum, sleY1731RmepReceive1dmCount,
|
||
sleY1731Rmep1dmFrameDelayMin, sleY1731Rmep1dmFrameDelayMax, sleY1731Rmep1dmFrameDelayAvg, sleY1731Rmep1dmFrameDelayVar, sleY1731RmepReceiveDmrCount,
|
||
sleY1731RmepDmrFrameDelayMin, sleY1731RmepDmrFrameDelayMax, sleY1731RmepDmrFrameDelayAvg, sleY1731RmepDmrFrameDelayVar, sleY1731LbrReceiveOrder,
|
||
sleY1731LbrRemoteMacAddress, sleY1731LtrSeqNumber, sleY1731LtrReceiveOrder, sleY1731LtrForwarded, sleY1731LtrTerminalMep,
|
||
sleY1731LtrLastEgressIdentifier, sleY1731LtrNextEgressIdentifier, sleY1731LtrRelay, sleY1731LtrIngress, sleY1731LtrIngressMac,
|
||
sleY1731LtrIngressPort, sleY1731LtrEgress, sleY1731LtrEgressMac, sleY1731LtrEgressPort, sleY1731ConfigErrorVid,
|
||
sleY1731ConfigErrorIfIndex, sleY1731ConfigErrorType, sleY1731MipCcdbIndex, sleY1731MipCcdbVlanId, sleY1731MipCcdbMacAddr,
|
||
sleY1731MipCcdbPort, sleY1731MipCcdbKeepTime, sleY1731RmepCreation, sleY1731BaseControlRmepCreation, sleY1731BaseControlTrunkIndex,
|
||
sleY1731BaseControlTrunkOamStatus, sleY1731TrunkIndex, sleY1731TrunkOamStatus, sleY1731BaseControlTrunkMeg, sleY1731TrunkMeg,
|
||
sleY1731MepLbSuccessRate, sleY1731MepTmLbmCount, sleY1731MepTmLbrCount, sleY1731MepTmTstCount, sleY1731RmepControlRequest,
|
||
sleY1731RMepControlStatus, sleY1731RmepControlTimer, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier,
|
||
sleY1731RmepControlMegIndex, sleY1731RmepControlIfIndex, sleY1731MegRapsEastPortStatus, sleY1731MegRapsWestPortStatus, sleY1731MegRapsNonRevertive,
|
||
sleY1731MegRapsForcedSwitchEast, sleY1731MegRapsForcedSwitchWest, sleY1731MegControlRapsNonRevertive, sleY1731MegControlRapsForcedSwitchEast, sleY1731MegControlRapsForcedSwitchWest,
|
||
sleY1731URMegName, sleY1731URDedicatedVlan, sleY1731UREnableStatus, sleY1731URConnectivityCheckMeg, sleY1731URPrimaryMepId,
|
||
sleY1731URSecondaryMepId, sleY1731URControlVlan, sleY1731URNodeConf, sleY1731URNodeConfPortNum, sleY1731URNonRevertive,
|
||
sleY1731URTrustMemberCount, sleY1731URWaitToRestore, sleY1731URControlRequest, sleY1731URControlStatus, sleY1731URControlTimer,
|
||
sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegName, sleY1731URControlDedicatedVlan, sleY1731URControlEnableStatus,
|
||
sleY1731URControlConnectivityCheckMeg, sleY1731URControlPrimaryMepId, sleY1731URControlSecondaryMepId, sleY1731URControlControlVlan, sleY1731URControlNodeConf,
|
||
sleY1731URControlNodeConfPortNum, sleY1731URControlNonRevertive, sleY1731URControlTrustMemberCount, sleY1731URControlWaitToRestore, sleY1731URMegIndex,
|
||
sleY1731URControlMegIndex, sleY1731URNodeConfPortStatus, sleY1731CCIgnoreDefect, sleY1731RapsFloodingBlock, sleY1731BaseControlCCIgnoreDefect,
|
||
sleY1731BaseControlRapsFloodingBlock, sleEMLogDisableStatus, sleEMLogAction, sleEMLogInterval, sleEMLogControlRequest,
|
||
sleEMLogControlStatus, sleEMLogControlTimer, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlDisableStatus,
|
||
sleEMLogControlAction, sleEMLogControlInterval, sleY1731MepLbRoundtripMin, sleY1731MepLbRoundtripMax, sleY1731MepLbRoundtripAvg,
|
||
sleCfmEnable, sleCfmLtrCacheHoldTime, sleCfmLtrCacheSize, sleCfmSnmpServerTraps, sleCfmXcheckStartDelay,
|
||
sleCfmBaseControlRequest, sleCfmBaseControlStatus, sleCfmBaseControlTimer, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult,
|
||
sleCfmBaseControlEnable, sleCfmBaseControlLtrCacheHoldTime, sleCfmBaseControlLtrCacheSize, sleCfmBaseControlSnmpServerTraps, sleCfmBaseControlXcheckStartDelay,
|
||
sleCfmBaseControlTrunkIndex, sleCfmBaseControlTrunkMdName, sleCfmBaseControlTrunkMaVid, sleCfmTrunkIndex, sleCfmTrunkMdName,
|
||
sleCfmTrunkMaVid, sleCfmMdIndex, sleCfmMdName, sleCfmMdLevel, sleCfmMdMepEnable,
|
||
sleCfmMdCcEnable, sleCfmMdCcInterval, sleCfmMdCcPriority, sleCfmMdCcLossThreshold, sleCfmMdCcHoldTime,
|
||
sleCfmMdFaultPriority, sleCfmMdFaultKeepTime, sleCfmMdFaultClearTime, sleCfmMdXcheckEnable, sleCfmMdControlRequest,
|
||
sleCfmMdControlStatus, sleCfmMdControlTimer, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex,
|
||
sleCfmMdControlName, sleCfmMdControlLevel, sleCfmMdControlMepEnable, sleCfmMdControlCcEnable, sleCfmMdControlCcInterval,
|
||
sleCfmMdControlCcPriority, sleCfmMdControlCcLossThreshold, sleCfmMdControlCcHoldTime, sleCfmMdControlFaultPriority, sleCfmMdControlFaultKeepTime,
|
||
sleCfmMdControlFaultClearTime, sleCfmMdControlXcheckEnable, sleCfmMaIndex, sleCfmMaName, sleCfmMaVid,
|
||
sleCfmMaMepEnable, sleCfmMaCcEnable, sleCfmMaCcInterval, sleCfmMaCcPriority, sleCfmMaCcLossThreshold,
|
||
sleCfmMaCcFaultPriority, sleCfmMaCcFaultKeepTime, sleCfmMaCcFaultClearTime, sleCfmMaXcheckEnable, sleCfmMaControlRequest,
|
||
sleCfmMaControlStatus, sleCfmMaControlTimer, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex,
|
||
sleCfmMaControlName, sleCfmMaControlVid, sleCfmMaControlMdIndex, sleCfmMaControlMepEnable, sleCfmMaControlCcEnable,
|
||
sleCfmMaControlCcInterval, sleCfmMaControlCcPriority, sleCfmMaControlCcLossThreshold, sleCfmMaControlFaultPriority, sleCfmMaControlFaultKeepTime,
|
||
sleCfmMaControlFaultClearTime, sleCfmMaControlXcheckEnable, sleCfmMepIdentifier, sleCfmMepIfIndex, sleCfmMepDirection,
|
||
sleCfmMepEnable, sleCfmMepFngState, sleCfmMepCcEnable, sleCfmMepMacAddress, sleCfmMepCcPriority,
|
||
sleCfmMepFaultPriority, sleCfmMepFaultKeepTime, sleCfmMepFaultClearTime, sleCfmMepHighestPrDefect, sleCfmMepDefects,
|
||
sleCfmMepCciSentCcms, sleCfmMepNextLbmTransId, sleCfmMepLbrIn, sleCfmMepLbrInOutOfOrder, sleCfmMepLtmNextSeqNumber,
|
||
sleCfmMepUnexpLtrIn, sleCfmMepControlRequest, sleCfmMepControlStatus, sleCfmMepControlTimer, sleCfmMepControlTimeStamp,
|
||
sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMepControlIfIndex,
|
||
sleCfmMepControlDirection, sleCfmMepControlEnable, sleCfmMepControlCcEnable, sleCfmMepControlCcPriority, sleCfmMepControlFaultPriority,
|
||
sleCfmMepControlFaultKeepTime, sleCfmMepControlFaultClearTime, sleCfmMepControlTransmitLbmDestMacAddress, sleCfmMepControlTransmitLbmDestMepId, sleCfmMepControlTransmitLbmDestIsMepId,
|
||
sleCfmMepControlTransmitLbmCount, sleCfmMepControlTransmitLbmInterval, sleCfmMepControlTransmitLbmTimeout, sleCfmMepControlTransmitLbmPriority, sleCfmMepControlTransmitLtmTargetMacAddress,
|
||
sleCfmMepControlTransmitLtmTargetMepId, sleCfmMepControlTransmitLtmTargetIsMepId, sleCfmMepControlTransmitLtmFlags, sleCfmMepControlTransmitLtmTtl, sleCfmMipPort,
|
||
sleCfmMipLevel, sleCfmMipType, sleCfmMipControlRequest, sleCfmMipControlStatus, sleCfmMipControlTimer,
|
||
sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort, sleCfmMipControlLevel, sleCfmXcheckMepIdentifier,
|
||
sleCfmXcheckMepState, sleCfmXcheckControlRequest, sleCfmXcheckControlStatus, sleCfmXcheckControlTimer, sleCfmXcheckControlTimeStamp,
|
||
sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex, sleCfmXcheckControlMaIndex, sleCfmRmepIdentifier,
|
||
sleCfmRmepState, sleCfmRmepMacAddress, sleCfmRmepIfIndex, sleCfmRmepRdi, sleCfmRmepPortStatus,
|
||
sleCfmRmepInterfaceStatus, sleCfmLtrSeqNumber, sleCfmLtrReceiveOrder, sleCfmLtrTtl, sleCfmLtrForwarded,
|
||
sleCfmLtrTerminalMep, sleCfmLtrLastEgressIdentifier, sleCfmLtrNextEgressIdentifier, sleCfmLtrRelay, sleCfmLtrIngress,
|
||
sleCfmLtrIngressMac, sleCfmLtrIngressPort, sleCfmLtrEgress, sleCfmLtrEgressMac, sleCfmLtrEgressPort,
|
||
sleCfmConfigErrorVid, sleCfmConfigErrorIfIndex, sleCfmConfigErrorType, sleCfmMipCcdbIndex, sleCfmMipCcdbVlanId,
|
||
sleCfmMipCcdbMacAddr, sleCfmMipCcdbPort, sleCfmMipCcdbKeepTime, sleRapsRingId, sleRapsRingType,
|
||
sleRapsRingLevel, sleRapsRingCtrlVlan, sleRapsRingTrafficVlans, sleRapsRingNodeId, sleRapsRingEnable,
|
||
sleRapsRingBridgeRole, sleRapsRingState, sleRapsRingEastPort, sleRapsRingEastPortStatus, sleRapsRingWestPort,
|
||
sleRapsRingWestPortStatus, sleRapsRingRplPort, sleRapsRingIcPort, sleRapsRingMultipleFailure, sleRapsRingPropagateTc,
|
||
sleRapsRingNonRevertive, sleRapsRingForcedSwitch, sleRapsRingHoldOffTime, sleRapsRingGuardTime, sleRapsRingWaitToRestore,
|
||
sleRapsRingWaitToBlock, sleRapsRingControlRequest, sleRapsRingControlStatus, sleRapsRingControlTimer, sleRapsRingControlTimeStamp,
|
||
sleRapsRingControlReqResult, sleRapsRingControlId, sleRapsRingControlType, sleRapsRingControlLevel, sleRapsRingControlCtrlVlan,
|
||
sleRapsRingControlTrafficVlans, sleRapsRingControlEnable, sleRapsRingControlEastPort, sleRapsRingControlWestPort, sleRapsRingControlBridgeRole,
|
||
sleRapsRingControlMultipleFailure, sleRapsRingControlPropagateTc, sleRapsRingControlNonRevertive, sleRapsRingControlHoldOffTime, sleRapsRingControlGuardTime,
|
||
sleRapsRingControlWaitToRestore, sleRapsRingControlWaitToBlock, sleY1731LbrTransId, sleY1731LbrRoundTripTime, sleY1731TlvPermission,
|
||
sleY1731BaseControlTlvPermission, sleY1731MepPmEnable, sleY1731MepCcmFrameLossNearRatio, sleY1731MepCcmFrameLossNearAvgRatio, sleY1731MepCcmFrameLossFarRatio,
|
||
sleY1731MepCcmFrameLossFarAvgRatio, sleY1731MepControlPmEnable, sleY1731RmepLmrFrameLossNearRatio, sleY1731RmepLmrFrameLossNearAvgRatio, sleY1731RmepLmrFrameLossFarRatio,
|
||
sleY1731RmepLmrFrameLossFarAvgRatio, sleY1731URSFCondition, sleY1731URControlSFCondition, sleAdvaOamControlMode, sleAlarmReportControlRequest,
|
||
sleAlarmReportControlStatus, sleAlarmReportControlTimer, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult, sleY1731URForceSwitch,
|
||
sleY1731URControlForceSwitch, sleEMLogDefectCPUHigh, sleEMLogTemperHigh, sleEMLogTemperLow, sleEMLogMemLow,
|
||
sleEMLogFanFail, sleEMLogPhyCRCFail, sleEMLogPhyDetectFail, sleEMLogSFUMateInitFail, sleEMLogDaemonHealthBad,
|
||
sleY1731LtrTtl, sleY1731LRMepIndex, sleY1731LRMepDMegIndex, sleY1731LRMepDMepIdentifier, sleY1731LRMepDRmepIdentifier,
|
||
sleY1731LRMepControlRequest, sleY1731LRMepControlStatus, sleY1731LRMepControlTimer, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult,
|
||
sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier, sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier,
|
||
sleY1731LRMepControlDRmepIdentifier, sleEMLogGPIURavenLinkDown, sleY1731MepRllcfGuardTime, sleY1731MepControlRllcfGuardTime, sleOamRemLoopbackCnt,
|
||
sleOamLm, sleOamLmAction, sleOamLmFrameWindow, sleOamLmFrameThresh, sleOamLmFrameTotal,
|
||
sleOamLmFramePeriodWindow, sleOamLmFramePeriodThresh, sleOamLmFramePeriodTotal, sleOamLmFrameSecondSummaryWindow, sleOamLmFrameSecondSummaryThresh,
|
||
sleOamLmFrameSecondSummaryTotal, sleOamLmSymbolPeriodWindow, sleOamLmSymbolPeriodThresh, sleOamLmSymbolPeriodTotal, sleOamLmRemSeqNum,
|
||
sleOamLmRemFrameLength, sleOamLmRemFrameTimeStamp, sleOamLmRemFrameWindow, sleOamLmRemFrameThresh, sleOamLmRemFrameErrors,
|
||
sleOamLmRemFrameErrorRunTotal, sleOamLmRemFrameEventRunTotal, sleOamLmRemFramePeriodLength, sleOamLmRemFramePeriodTimeStamp, sleOamLmRemFramePeriodWindow,
|
||
sleOamLmRemFramePeriodThresh, sleOamLmRemFramePeriodErrors, sleOamLmRemFramePeriodErrorRunTotal, sleOamLmRemFramePeriodEventRunTotal, sleOamLmRemFrameSecondSummaryLength,
|
||
sleOamLmRemFrameSecondSummaryTimeStamp, sleOamLmRemFrameSecondSummaryWindow, sleOamLmRemFrameSecondSummaryThresh, sleOamLmRemFrameSecondSummaryErrors, sleOamLmRemFrameSecondSummaryErrorRunTotal,
|
||
sleOamLmRemFrameSecondSummaryEventRunTotal, sleOamLmRemSymbolPeriodLength, sleOamLmRemSymbolPeriodTimeStamp, sleOamLmRemSymbolPeriodWindow, sleOamLmRemSymbolPeriodThresh,
|
||
sleOamLmRemSymbolPeriodErrors, sleOamLmRemSymbolPeriodErrorRunTotal, sleOamLmRemSymbolPeriodEventRunTotal, sleOamControlRemLoopbackPkCnt, sleOamControlLm,
|
||
sleOamControlLmAction, sleOamControlLmFrameWindow, sleOamControlLmFrameThresh, sleOamControlLmFramePeriodWindow, sleOamControlLmFramePeriodThresh,
|
||
sleOamControlLmFrameSecondSummaryWindow, sleOamControlLmFrameSecondSummaryThresh, sleOamControlLmSymbolPeriodWindow, sleOamControlLmSymbolPeriodThresh, sleY1731LtrRoundTripTime,
|
||
sleY1731MepRllcf, sleY1731MepRllcfHoldOff, sleY1731MepControlRllcf, sleY1731MepControlRllcfHoldOff, sleRapsRingInstId,
|
||
sleRapsRingChannel, sleRapsRingPassThrough, sleRapsRingManualSwitch, sleRapsRingVerifiedTime, sleRapsRingControlInstId,
|
||
sleRapsRingVirtualVlan, sleRapsRingIcNode, sleY1731URTrafficVlan, sleY1731URState, sleY1731URControlTrafficVlan,
|
||
sleAlarmReportPairType, sleAlarmHistoryPairType, sleY1731URManualSwitch, sleY1731URControlManualSwitch, sleEMLogNAKLockStatus,
|
||
sleEMLogNakCompensate, sleEMLogRecoverActionMemLow, sleEMLogRecoverActionNak, sleEMLogControlNAKLockStatus, sleEMLogControlNAKCompensate,
|
||
sleEMLogControlRecoverActionMemLow, sleEMLogControlRecoverActionNAK, sleEMLogNAK, sleFaultMonitorGlobalInspectInterval, sleFaultMonitorGlobalStartupThreshold,
|
||
sleFaultMonitorGlobalNoKeepalive, sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlStatus, sleFaultMonitorGlobalControlTimer, sleFaultMonitorGlobalControlTimeStamp,
|
||
sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlInspectInterval, sleFaultMonitorGlobalControlStartupThreshold, sleFaultMonitorGlobalControlNoKeepalive, sleFaultMonitorDaemonName,
|
||
sleFaultMonitorDaemonPid, sleFaultMonitorDaemonAdminStatus, sleFaultMonitorDaemonCrashAction, sleFaultMonitorDaemonTimeoutAction, sleFaultMonitorDaemonThreshold,
|
||
sleFaultMonitorDaemonThresholded, sleFaultMonitorDaemonStartupThresholded, sleFaultMonitorDaemonWatchdogAdminStatus, sleFaultMonitorDaemonWatchdogThreshold, sleFaultMonitorDaemonWatchdogCount,
|
||
sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlStatus, sleFaultMonitorDaemonControlTimer, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult,
|
||
sleFaultMonitorDaemonControlAdminStatus, sleFaultMonitorDaemonControlCrashAction, sleFaultMonitorDaemonControlTimeoutAction, sleFaultMonitorDaemonControlThreshold, sleFaultMonitorDaemonControlWatchdogAdminStatus,
|
||
sleFaultMonitorDaemonControlWatchdogThreshold, sleFaultMonitor2pointsLinearAdminStatus, sleFaultMonitor2pointsLinearInterval, sleFaultMonitor2pointsLinearThreshold, sleFaultMonitor2pointsLinearControlRequest,
|
||
sleFaultMonitor2pointsLinearControlStatus, sleFaultMonitor2pointsLinearControlTimer, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2pointsLinearControlAdminStatus,
|
||
sleFaultMonitor2PonitsLinearControlInterval, sleFaultMonitor2PointsLinearControlThreshold, sleFaultMonitorRHMAdminStatus, sleFaultMonitorRHMActionType, sleFaultMonitorRHMActionThreshold,
|
||
sleFaultMonitorRHMRebootThreshold, sleFaultMonitorRHMRecoveryTime, sleFaultMonitorRHMFaultCounter, sleFaultMonitorRHMRebootCounter, sleFaultMonitorRHMHostAddr,
|
||
sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlStatus, sleFaultMonitorRHMControlTimer, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult,
|
||
sleFaultMonitorRHMControlAdminStatus, sleFaultMonitorRHMControlActionType, sleFaultMonitorRHMControlActionThreshold, sleFaultMonitorRHMControlRebootThreshold, sleFaultMonitorRHMControlRecoveryTime,
|
||
sleFaultMonitorRHMControlHostAddr, sleEMLogFANRPMLow, sleFaultMonitorRHMInterval, sleFaultMonitorRHMLiveThreshold, sleFaultMonitorRHMControlInterval,
|
||
sleFaultMonitorRHMControlLiveThreshold, sleY1731MegMd, sleY1731MegControlMd, sleFaultMonitorDaemonControlName, sleFaultMonitorDaemonControlThreshed,
|
||
sleFaultMonitorDaemonControlStartupThresh, sleAlarmReportControlSpecificCode, sleAlarmReportControlSourceType, sleAlarmReportControlSource, sle2EthCfmEnable,
|
||
sle2EthCfmLmmFrameCountSimStatus, sle2EthCfmControlRequest, sle2EthCfmControlStatus, sle2EthCfmControlTimer, sle2EthCfmControlTimeStamp,
|
||
sle2EthCfmControlReqResult, sle2EthCfmControlEnable, sle2EthCfmControlLmmFrameCountSimStatus, sle2EthCfmBridgeId, sle2EthCfmBridgeDefaultMdLevel,
|
||
sle2EthCfmBridgeDefaultMepId, sle2EthCfmBridgeAutomatic, sle2EthCfmBridgeConfigDefaultMdLevel, sle2EthCfmBridgeConfigDefaultMdMipCreation, sle2EthCfmBridgeLtrCacheEnable,
|
||
sle2EthCfmBridgeLtrCacheSize, sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlStatus, sle2EthCfmBridgeControlTimer, sle2EthCfmBridgeControlTimeStamp,
|
||
sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlId, sle2EthCfmBridgeControlDefaultMdLevel, sle2EthCfmBridgeControlDefaultMepId, sle2EthCfmBridgeControlAutomatic,
|
||
sle2EthCfmBridgeControlConfigDefaultMdLevel, sle2EthCfmBridgeControlConfigDefaultMdMipCreation, sle2EthCfmBridgeConntrolLtrCacheEnable, sle2EthCfmBridgeControlLtrCacheSize, sle2EthCfmVlanConfigPrimaryVid,
|
||
sle2EthCfmVlanConfigSecondaryVid, sle2EthCfmVlanConfigSecondaryBridgeId, sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlStatus, sle2EthCfmVlanConfigControlTimer,
|
||
sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlPrimaryBridgeId, sle2EthCfmVlanConfigControlPrimaryVid, sle2EthCfmVlanConfigControlSecondaryBridgeId,
|
||
sle2EthCfmVlanConfigControlSecondaryVid, sle2EthCfmVlanInfoVid, sle2EthCfmVlanInfoPriority, sle2EthCfmVlanInfoControlRequest, sle2EthCfmVlanInfoControlStatus,
|
||
sle2EthCfmVlanInfoControlTimer, sle2EthCfmVlanInfoControlTimeStamp, sle2EthCfmVlanInfoControlReqResult, sle2EthCfmVlanInfoControlBridgeId, sle2EthCfmVlanInfoControlVid,
|
||
sle2EthCfmVlanInfoControlPriority, sle2EthCfmDefMdLevelEntryVid, sle2EthCfmDefMdLevelEntryLevel, sle2EthCfmDefMdLevelEntryMipCreation, sle2EthCfmDefMdLevelEntryControlRequest,
|
||
sle2EthCfmDefMdLevelEntryControlStatus, sle2EthCfmDefMdLevelEntryControlTimer, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlBridgeId,
|
||
sle2EthCfmDefMdLevelEntryControlVid, sle2EthCfmDefMdLevelEntryControlLevel, sle2EthCfmDefMdLevelEntryControlMipCreation, sle2EthCfmMdName, sle2EthCfmMdType,
|
||
sle2EthCfmMdLevel, sle2EthCfmMdMipCreation, sle2EthCfmMdControlRequest, sle2EthCfmMdControlStatus, sle2EthCfmMdControlTimer,
|
||
sle2EthCfmMdControlTimeStamp, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlBridgeId, sle2EthCfmMdControlType, sle2EthCfmMdControlName,
|
||
sle2EthCfmMdControlLevel, sle2EthCfmMdControlMipCreation, sle2EthCfmMaName, sle2EthCfmMaVid, sle2EthCfmMaType,
|
||
sle2EthCfmMaMipCreation, sle2EthCfmMaCcInterval, sle2EthCfmMaElmi, sle2EthCfmMaConnectivityStatus, sle2EthCfmMaConfiguredRmepCount,
|
||
sle2EthCfmMaConvergedRmepCount, sle2EthCfmMaControlRequest, sle2EthCfmMaControlStatus, sle2EthCfmMaControlTimer, sle2EthCfmMaControlTimeStamp,
|
||
sle2EthCfmMaControlReqResult, sle2EthCfmMaControlBridgeId, sle2EthCfmMaControlMdName, sle2EthCfmMaControlName, sle2EthCfmMaControlType,
|
||
sle2EthCfmMaControlVid, sle2EthCfmMaControlMipCreation, sle2EthCfmMaControlCcmInterval, sle2EthCfmMaControlElmi, sle2EthCfmMepInfoId,
|
||
sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoLocalVid, sle2EthCfmMepInfoDirection, sle2EthCfmMepInfoActive, sle2EthCfmMepInfoUNI,
|
||
sle2EthCfmMepInfoCcmStatus, sle2EthCfmMepInfoCcmType, sle2EthCfmMepInfoCcmRmepId, sle2EthCfmMepInfoLocalMacAddr, sle2EthCfmMepInfoRdi,
|
||
sle2EthCfmMepInfoService, sle2EthCfmMepInfoLckLevel, sle2EthCfmMepInfoConnectivityStatus, sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlStatus,
|
||
sle2EthCfmMepInfoControlTimer, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
|
||
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlIfindex, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlLocalVid, sle2EthCfmMepInfoControlMepDirection,
|
||
sle2EthCfmMepInfoControlActive, sle2EthCfmMepInfoControlUNI, sle2EthCfmMepInfoControlCcmStatus, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlRmepId,
|
||
sle2EthCfmMepInfoControlService, sle2EthCfmMepInfoControlLckLevel, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive, sle2EthCfmMepInfoControlTstTxInterval,
|
||
sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepAttrActive, sle2EthCfmMepAttrCcmLtmPriority, sle2EthCfmMepAttrLowPrDef,
|
||
sle2EthCfmMepAttrFngAlarmTime, sle2EthCfmMepAttrResetFngTime, sle2EthCfmMepAttrCcmLtmFlag, sle2EthCfmMepAttrTxLtmTargetMac, sle2EthCfmMepAttrTxLtmTargetMepId,
|
||
sle2EthCfmMepAttrTxLtmTargetIsMepId, sle2EthCfmMepAttrTxLtmTtl, sle2EthCfmMepAttrTxLtmEgressId, sle2EthCfmMepAttrTxLbmStatus, sle2EthCfmMepAttrTxLbmDestMac,
|
||
sle2EthCfmMepAttrTxLbmDestMepId, sle2EthCfmMepAttrTxLbmDestIsMepId, sle2EthCfmMepAttrTxLbmMessages, sle2EthCfmMepAttrTxLbmDataTlv, sle2EthCfmMepAttrTxLbmVlanPriority,
|
||
sle2EthCfmMepAttrTxLbmVlanDropEnable, sle2EthCfmMepAttrTxLbmTimeOut, sle2EthCfmMepAttrLbrTimeOut, sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlStatus,
|
||
sle2EthCfmMepAttrControlTimer, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlBridgeId, sle2EthCfmMepAttrControlMdName,
|
||
sle2EthCfmMepAttrControlMaVid, sle2EthCfmMepAttrControlMepId, sle2EthCfmMepAttrControlActive, sle2EthCfmMepAttrControlCcmLtmPriority, sle2EthCfmMepAttrContrlLowPrDef,
|
||
sle2EthCfmMepAttrContrlFngAlarmTime, sle2EthCfmMepAttrControlResetFngTime, sle2EthCfmMepAttrControlCcmLtmFlag, sle2EthCfmMepAttrControlTxLtmTargetMac, sle2EthCfmMepAttrControlTxLtmTargetMepId,
|
||
sle2EthCfmMepAttrControlTxLtmTargetIsMepId, sle2EthCfmMepAttrControlTxLtmTtl, sle2EthCfmMepAttrControlTxLtmEgressId, sle2EthCfmMepAttrControlTxLbmStatus, sle2EthCfmMepAttrControlTxLbmDestMacAddress,
|
||
sle2EthCfmMepAttrControlTxLbmDestMepId, sle2EthCfmMepAttrControlTxLbmDestIsMepId, sle2EthCfmMepAttrControlTxLbmMessages, sle2EthCfmMepAttrControlTxLbmDataTlv, sle2EthCfmMepAttrControlTxLbmVlanPriority,
|
||
sle2EthCfmMepAttrControlTxLbmVlanDropEnable, sle2EthCfmMepAttrControlTxLbmTimeOut, sle2EthCfmMepAttrControlLbrTimeOut, sle2EthCfmXcheckRmepId, sle2EthCfmXcheckRmepMac,
|
||
sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlStatus, sle2EthCfmXcheckControlTimer, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmXcheckControlReqResult,
|
||
sle2EthCfmXcheckControlBridgeId, sle2EthCfmXcheckControlMdName, sle2EthCfmXcheckControlMaVid, sle2EthCfmXcheckControlRmepId, sle2EthCfmXcheckControlRmepMac,
|
||
sle2EthCfmLbReceivedCount, sle2EthCfmLbRemoteMacAddress, sle2EthCfmLbTxMessages, sle2EthCfmLbResponseCount, sle2EthCfmLbControlRequest,
|
||
sle2EthCfmLbControlStatus, sle2EthCfmLbControlTimer, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlBridgeId,
|
||
sle2EthCfmLbControlMdName, sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepId,
|
||
sle2EthCfmLbControlRmepMac, sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest, sle2EthCfmLbControlRecursive, sle2EthCfmLtrMepMac,
|
||
sle2EthCfmLtrHops, sle2EthCfmLtrRelay, sle2EthCfmLtrIngressEgress, sle2EthCfmLtrIngress, sle2EthCfmLtrEgress,
|
||
sle2EthCfmLtControlRequest, sle2EthCfmLtControlStatus, sle2EthCfmLtControlTimer, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlReqResult,
|
||
sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMdName, sle2EthCfmLtControlMaVid, sle2EthCfmLtControlLevel, sle2EthCfmLtControlRmepMac,
|
||
sle2EthCfmAisInfoStatus, sle2EthCfmAisInfoDefectConditions, sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoFrameType, sle2EthCfmAisInfoRmepMac,
|
||
sle2EthCfmAisInfoInterval, sle2EthCfmAisInfoReceivedDefectConditions, sle2EthCfmAisInfoLastReceivedDefectCondition, sle2EthCfmAisInfoControlRequest, sle2EthCfmAisInfoControlStatus,
|
||
sle2EthCfmAisInfoControlTimer, sle2EthCfmAisInfoControlTimeStamp, sle2EthCfmAisInfoControlReqResult, sle2EthCfmAisInfoControlBridgeId, sle2EthCfmAisInfoControlMdName,
|
||
sle2EthCfmAisInfoControlMaVid, sle2EthCfmAisInfoControlMepId, sle2EthCfmAisInfoControlEnable, sle2EthCfmAisInfoControlDefectConditions, sle2EthCfmAisInfoControlLevel,
|
||
sle2EthCfmAisInfoControlFrameType, sle2EthCfmAisInfoControlRmepMac, sle2EthCfmAisInfoControlInterval, sle2EthCfmSrvAisIfIndex, sle2EthCfmSrvAisEnable,
|
||
sle2EthCfmSrvAislevel, sle2EthCfmSrvAisInterval, sle2EthCfmSrvAisControlRequest, sle2EthCfmSrvAisControlStatus, sle2EthCfmSrvAisControlTimer,
|
||
sle2EthCfmSrvAisControlTimeStamp, sle2EthCfmSrvAisControlReqResult, sle2EthCfmSrvAisControlBridgeId, sle2EthCfmSrvAisControlIfIndex, sle2EthCfmSrvAisControlEnable,
|
||
sle2EthCfmSrvAisControlLevel, sle2EthCfmSrvAisControlInterval, sle2EthCfmLmmStatusRmepId, sle2EthCfmLmmStatusStartTime, sle2EthCfmLmmStatusCurrentTime,
|
||
sle2EthCfmLmmStatusEndTime, sle2EthCfmLmmStatusNeerLoss, sle2EthCfmLmmStatusFarLoss, sle2EthCfmLmmStatusCurNeerLoss, sle2EthCfmLmmStatusCurFarLoss,
|
||
sle2EthCfmRmepId, sle2EthCfmRempMepId, sle2EthCfmRmepLevel, sle2EthCfmRmepMaVid, sle2EthCfmRmepActiveState,
|
||
sle2EthCfmRmepRemoteMac, sle2EthCfmRmepRdi, sle2EthCfmRmepFlags, sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlStatus,
|
||
sle2EthCfmRmepControlTimer, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdName,
|
||
sle2EthCfmRmepControlMdLevel, sle2EthCfmMipVid, sle2EthCfmMipMdLevel, sle2EthCfmMipIfindex, sle2EthCfmMipLocalMac,
|
||
sle2EthCfmStatCcmSent, sle2EthCfmStatCcmRevOutOfSeq, sle2EthCfmStatLbrSent, sle2EthCfmStatLbrRevValid, sle2EthCfmStatLbrRevBadMsdu,
|
||
sle2EthCfmStatLbrRevOutOfSeq, sle2EthCfmStatLtrRevUnexpected, sle2EthCfmAcitveLevelIfIndex, sle2EthCfmActiveLevelStatus, sle2EthCfmErrorIndex,
|
||
sle2EthCfmErrorMdLevel, sle2EthCfmErrorMaVid, sle2EthCfmErrorMepId, sle2EthCfmErrorRmepMac, sle2EthCfmErrorReason,
|
||
sle2EthCfmErrorServiceId, sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlStatus, sle2EthCfmErrorControlTimer, sle2EthCfmErrorControlTimeStamp,
|
||
sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlBridgeId, sle2EthCfmErrorControlMdName, sle2EthCfmErrorControlMdLevel, sle2EthCfmLtCacheIndex,
|
||
sle2EthCfmLtCacheSrcMac, sle2EthCfmLtCacheHops, sle2EthCfmLtCacheRelay, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
|
||
sle2ErpsPhyRingEastPort, sle2ErpsPhyRingWestPort, sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlStatus, sle2ErpsPhyRingControlTimer,
|
||
sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName, sle2ErpsPhyRingControEastPort,
|
||
sle2ErpsPhyRingControWestPort, sle2ErpsProfileBridgeId, sle2ErpsProfileName, sle2ErpsProfileHoldOffTime, sle2ErpsProfileGuardTime,
|
||
sle2ErpsProfileWaitToRestore, sle2ErpsProfileNonRevertive, sle2ErpsProfileControlRequest, sle2ErpsProfileControlStatus, sle2ErpsProfileControlTimer,
|
||
sle2ErpsProfileControlTimeStamp, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlBridgeId, sle2ErpsProfileControlName, sle2ErpsProfileControlHoldOffTime,
|
||
sle2ErpsProfileControlGuardTime, sle2ErpsProfileControlWaitToRestore, sle2ErpsProfileControlNonRevertive, sle2ErpsInstBridgeId, sle2ErpsInstName,
|
||
sle2ErpsInstPhyRingName, sle2ErpsInstProfileName, sle2ErpsInstRingId, sle2ErpsInstLevel, sle2ErpsInstRplRole,
|
||
sle2ErpsInstRplRolePort, sle2ErpsInstSubRingBlock, sle2ErpsInstCtrlVlan, sle2ErpsInstTafficVlans, sle2ErpsInstVChannelVid,
|
||
sle2ErpsInstVChannelAttachInstName, sle2ErpsInstPropagateTc, sle2ErpsInstStatus, sle2ErpsInstEastPortStatus, sle2ErpsInstWestPortStatus,
|
||
sle2ErpsInstControlRequest, sle2ErpsInstControlStatus, sle2ErpsInstControlTimer, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlReqResult,
|
||
sle2ErpsInstControlBridgeId, sle2ErpsInstControlName, sle2ErpsInstControlPhyRingName, sle2ErpsInstControlProfileName, sle2ErpsInstControlRingId,
|
||
sle2ErpsInstControlLevel, sle2ErpsInstControlRplRole, sle2ErpsInstControlRplRolePort, sle2ErpsInstControlSubRingBlock, sle2ErpsInstControlCtrlVlan,
|
||
sle2ErpsInstControlTafficVlans, sle2ErpsInstControlVChannelVid, sle2ErpsInstControlVChannelAttachInstName, sle2ErpsInstControlForcedSwitch, sle2ErpsInstControlManualSwitch,
|
||
sle2ErpsInstControlPropagateTc, sle2ErpsInstControlVersion, sleRapsRingControlIcNode, sleRapsRingControlChannel, sleRapsRingControlParamPort,
|
||
sleRapsRingControlPassThrough, sleRapsRingControlVerifiedTime, sle2EthCfmMepInfoDlmState, sle2EthCfmMepInfoDlmRmepId, sle2EthCfmMepInfoControlDlmState,
|
||
sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval, sle2EthCfmMepInfoControlTransMode, sle2EthCfmLbFrameType, sle2EthCfmLbControlTlvType,
|
||
sle2ErpsPhyRingEastMepId, sle2ErpsPhyRingEastRmepId, sle2ErpsPhyRingWestMepId, sle2ErpsPhyRingWestRmepId, sle2ErpsPhyRingControlMepId,
|
||
sle2ErpsPhyRingControlRmepId, sle2ErpsInstChannelMode, sle2ErpsInstActive, sle2ErpsInstEastIfindex, sle2ErpsInstWestIfindex,
|
||
sle2EthCfmMepInfoInterval, sle2ErpsInstControlActive, sle2EthCfmLtControlMepId, sle2ErpsInstVersion, sle2ErpsInstDataTrafficInheritanceInstName,
|
||
sle2ErpsInstControlDataTrafficInheritanceInstName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMgmt 19 }
|
||
|
||
|
||
sleFaultMgmtNotificationGroup NOTIFICATION-GROUP
|
||
NOTIFICATIONS { sleAlarmDefaultSeverityChanged, sleAlarmDefaultCriteriaChanged, sleNotificationActivityChanged, sleAlarmSeveriityCreated, sleAlarmSeveriityDestroyed,
|
||
sleAlarmSeverityChanged, sleAlarmReportNotified, sleAlarmHistoryCleared, sleEfmOamPortProfileChanged, sleEfmOamPortRemLoopback,
|
||
sleAdvaSystemProfileChanged, sleAdvaAlarmProfileChanged, sleAdvaElectricalInterfaceChanged, sleAdvaGeneralProfileChanged, sleAdvaAutonegProfileChanged,
|
||
sleAdvaOpticalAlarmChanged, sleAlarmLEDOffChanged, sleAlarmLEDLevelChanged, sleAlarmLEDCleared, sleAlarmLEDBlockChanged,
|
||
sleY1731EnableChanged, sleY1731TrunkEnableChanged, sleY1731LtrCacheProfileChanged, sleY1731SnmpProfileChanged, sleY1731XcheckProfileChanged,
|
||
sleY1731DefaultMegProfileChanged, sleY1731PduToCfmChanged, sleY1731DedicatedVlanChanged, sleY1731MipCcdbDestroyed, sleY1731LtrCacheDestroyed,
|
||
sleY1731MegCreated, sleY1731MegDeleted, sleY1731MegMepEnableChanged, sleY1731MegCcEnableChanged, sleY1731MegCcProfileChanged,
|
||
sleY1731MegFaultProfileChanged, sleY1731MegXcheckEnableChanged, sleY1731MegAisEnableChanged, sleY1731MegAisTransmitEnableChanged, sleY1731MegAisProfileChanged,
|
||
sleY1731MegLckEnableChanged, sleY1731MegLckTransmitEnableChanged, sleY1731MegLckProfileChanged, sleY1731MegOutOfServiceChanged, sleY1731MegRapsEnableChanged,
|
||
sleY1731MegRapsRingportsChanged, sleY1731MegRapsRplPortChanged, sleY1731MegRapsRplOwnerChanged, sleY1731MegRapsTimerChanged, sleY1731MegRemoteMepDestroyed,
|
||
sleY1731MegErrorDestroyed, sleY1731MepCreated, sleY1731MepDeleted, sleY1731MepEnableChanged, sleY1731MepCcEnableChanged,
|
||
sleY1731MepFaultProfileChanged, sleY1731MepAisEnableChanged, sleY1731MepAisTransmitEnableChanged, sleY1731MepLckEnableChanged, sleY1731MepLckTransmitEnableChanged,
|
||
sleY1731MepOutOfServiceChanged, sleY1731MepDlmEnableChanged, sleY1731MepTransmitLbmFinished, sleY1731MepTransmitLtmFinished, sleY1731MepTransmitTstLbmFinished,
|
||
sleY1731MepTransmitTmLbmFinished, sleY1731MepTransmitTstFinished, sleY1731MepReceiveTstFinished, sleY1731MepTransmitTmTstFinished, sleY1731MepReceiveTmTstFinished,
|
||
sleY1731MepTransmitLmmFinished, sleY1731MepTransmit1dmFinished, sleY1731MepReceive1dmFinished, sleY1731MepTransmitDmmFinished, sleY1731MipCreated,
|
||
sleY1731MipDeleted, sleY1731XcheckMepCreated, sleY1731XcheckMepDeleted, sleY1731CcMacCreated, sleY1731CcMacDeleted,
|
||
sleY1731AisMacCreated, sleY1731AisMacDeleted, sleY1731LckMacCreated, sleY1731LckMacDeleted, sleY1731RmepCreationChanged,
|
||
sleY1731TrunkOamStatusChanged, sleY1731RmepCreated, sleY1731RmepDeleted, sleY1731MegRapsNonRevertiveChanged, sleY1731MegRapsForcedSwitchEastChanged,
|
||
sleY1731MegRapsForcedSwitchWestChanged, sleY1731URDedicatedVlanChanged, sleY1731UREnableStatusChanged, sleY1731URCCPrimaryMepIdChanged, sleY1731URCCPrimaryMepIdCleared,
|
||
sleY1731URCCSecondaryMepIdChanged, sleY1731URCCSecondaryMepIdCleared, sleY1731URControlVlanChanged, sleY1731URNodeConfChanged, sleY1731URNodeConfCleared,
|
||
sleY1731URNonRevertiveChanged, sleY1731URTrustMemberCountChanged, sleY1731URTrustMemberCountCleared, sleY1731URWaitToRestoreChanged, sleY1731URWaitToRestoreCleared,
|
||
sleY1731URControlVlanCleared, sleY1731URForceSwitchChanged, sleY1731URManualSwitchChanged, sleY1731CCIgnoreDefectChanged, sleY1731RapsFloodinBlockChanged,
|
||
sleEMLogDisableStatusChanged, sleEMLogActionChanged, sleEMLogIntervalChanged, sleCfmEnableChanged, sleCfmLtrCacheProfileChanged,
|
||
sleCfmSnmpServerTrapsChanged, sleCfmXcheckStartDelayChanged, sleCfmMipCcdbDestroyed, sleCfmLtrCacheDestroyed, sleCfmTrunkPortCreated,
|
||
sleCfmTrunkPortDeleted, sleCfmMdCreated, sleCfmMdDeleted, sleCfmMdMepEnableChanged, sleCfmMdCcEnableChanged,
|
||
sleCfmMdCcProfileChanged, sleCfmMdFaultProfileChanged, sleCfmMdXcheckEnableChanged, sleCfmMdErrorDestoryed, sleCfmMdRmepDestoryed,
|
||
sleCfmMaCreated, sleCfmMaDeleted, sleCfmMaMepEnableChanged, sleCfmMaCcEnableChanged, sleCfmMaCcProfileChanged,
|
||
sleCfmMaFaultProfileChanged, sleCfmMaXcheckEnableChanged, sleCfmMepCreated, sleCfmMepDeleted, sleCfmMepEnableChanged,
|
||
sleCfmMepCcEnableChanged, sleCfmMepCcProfileChanged, sleCfmMepFaultProfileChanged, sleCfmMipCreated, sleCfmMipDeleted,
|
||
sleCfmXcheckMepCreated, sleCfmXcheckMepDeleted, sleRapsRingCreated, sleRapsRingDeleted, sleRapsRingEnableChanged,
|
||
sleRapsRingPortsCreated, sleRapsRingPortsDestroyed, sleRapsRingRplPortChanged, sleRapsRingMultipleFailureChanged, sleRapsRingPropagateTcChanged,
|
||
sleRapsRingNonRevertiveChanged, sleRapsRingForcedSwitchChanged, sleRapsRingManualSwitchChanged, sleRapsRingSwitchCleared, sleRapsRingHoldOffTimeChanged,
|
||
sleRapsRingGuardTimeChanged, sleRapsRingWtrTimeChanged, sleRapsRingWtbTimeChanged, sleY1731TlvPermissionChanged, sleY1731MepPmEnableChanged,
|
||
sleY1731LRMepCreated, sleY1731LRMEPDeleted, setAdvaOamProfileChanged, sleAlarmReportCleared, sleEfmOamPortLinkMonitorChanged,
|
||
sleRapsRingIcPortCreated, sleRapsRingIcPortDestroyed, sleY1731URTrafficVlanChanged, sleY1731URTrafficVlanCleared, sleEMLogNAKLockChanged,
|
||
sleEMLogNAKCompensateChanged, sleEMLogRecoverActionMemLowChanged, sleEMLogRecoverActionNAKChanged, setFaultMonitorGlobalInspectIntervalChanged, setFaultMonitorGlobalStartupThresholdChanged,
|
||
setFaultMonitorGlobalNoKeepaliveActionChanged, setFaultMonitorDaemonAdminStatusChanged, setFaultMonitorDaemonFaultActionChanged, setFaultMonitorDaemonThresholdChanged, setFaultMonitorDaemonWatchdogchanged,
|
||
sleFaultMonitor2PointsLinearAdminStatusChanged, sleFaultMonitor2PointsLinearIntervalChanged, sleFaultMonitor2PointsLinearThresholdChanged, setRHMStatusChanged, setRHMActionThresholdChanged,
|
||
setRHMRebootThresholdChanged, setRHMHostAdded, setRHMHostCleared, sleY1731MegMdAdded, sleY1731MegMdDeleted,
|
||
sleAlarmReportDeleted, sle2EthCfmEnableChanged, sle2EthCfmLmmFrameCountSimulatorChanged, setCfmBridgeProfile, setCfmBridgeLtrCacheEnable,
|
||
clearCfmBridgeLtrCache, setCfmBridgeAutomatic, setCfmBridgeConfigDefaultMdLevel, addCfmVlanConfVid, delCfmVlanConfVid,
|
||
sle2EthCfmVlanPriorityChanged, sle2EthCfmDefMdLevelEntryChanged, sle2EthCfmDefMdLevelEntryCleared, sle2EthCfmMdCreated, sle2EthCfmMdDestoryed,
|
||
sle2EthCfmMaCreated, sle2EthCfmMaDestoryed, sle2EthCfmCcIntervalChanged, sle2EthCfmElmiChanged, sle2EthCfmMepCreated,
|
||
sle2EthCfmMepDestory, sle2EthCfmCcEnableChanged, sle2EthCfmServiceChanged, sle2EthCfmTransmitUnicastTstFinished, sle2EthCfmTransmitMulticastTstFinished,
|
||
sle2EthCfmTransmitExmFinished, sle2EthCfmTransmitVsmFinished, sle2EthCfmTransmitMccFinished, sle2EthCfmMepFaultProfileChanged, sle2EthCfmMepTxLtmProfileChanged,
|
||
sle2EthCfmMepTxLbmProfileChanged, sle2EthCfmMepAuttributesAllCleared, sle2EthCfmXcheckMepCreated, sle2EthCfmXcheckMepDestoryed, sle2EthCfmLbTransmitMulticastFinished,
|
||
sle2EthCfmLbTransmitUnicastFinished, sle2EthCfmLbTransmitMacFinished, sle2EthCfmLbrFinished, sle2EthCfmLtTransmitDomainFinished, sle2EthCfmLtTransmitLevelFinished,
|
||
sle2EthCfmLtrFinished, sle2EthCfmAisInfoStatusChanged, sle2EthCfmAisInfoIntervalChanged, sle2EthCfmSrvAisChanged, sle2EthCfmRmepDomainCleared,
|
||
sle2EthCfmRmepLevelCleared, sle2EthCfmErrorDomainCleared, sle2EthCfmErrorLevelCleared, sle2ErpsPhyRingCreated, sle2ErpsPhyRingDestoryed,
|
||
sle2ErpsPhyRingEastPortAdded, sle2ErpsPhyRingEastPortDeleted, sle2ErpsPhyRingWestPortAdded, sle2ErpsPhyRingWestPortDeleted, sle2ErpsProfileCreated,
|
||
sle2ErpsProfileDestoryed, sle2ErpsProfileTimerChanged, sle2ErpsProfileNoneRevertiveChanged, sle2ErpsInstCreated, sle2ErpsInstDestoryed,
|
||
sle2ErpsInstRingIdChanged, sle2ErpsInstLevelChanged, sle2ErpsInstRplRoleChanged, sle2ErpsInstSubRingAdded, sle2ErpsInstSubRingDeleted,
|
||
sle2ErpsInstCtrlVlanAdded, sle2ErpsInstCtrlVlanDeleted, sle2ErpsInstDataTrafficVlanAdded, sle2ErpsInstDataTrafficVlanDeleted, sle2ErpsInstForcedSwichChanged,
|
||
sle2ErpsInstManualSwichChanged, sle2ErpsInstClearChanged, sle2ErpsInstPropagateTcChanged, sle2ErpInstVersionChanged, sle2ErpInstDataTrafficInheritanceInstNameChanged,
|
||
sle2ErpInstDataTrafficInheritanceInstNameDeleted, sleY1731URSFConditionChanged, sleY1731MepRllcfChanged, sleRapsRingChannelChanged, sleRapsRingPassThroughChanged,
|
||
sleRapsRingVrfTimeChanged, sle2EthCfmDualEndLmmChanged, sle2EthCfmTransmitUnicastLmFinished, sle2EthCfmTransmitMulticastLmFinished, sle2EthCfmTransmitUnicastDmFinished,
|
||
sle2EthCfmTransmitMuliticastDmFinished, sle2EthCfmReceive1DmFinished, sle2EthCfmTransmitTmFinished, sle2EthCfmReceiveTmFinished, sle2ErpsPhyRingEastMepIdAdded,
|
||
sle2ErpsPhyRingEastMepIdDeleted, sle2ErpsPhyRingWestMepIdAdded, sle2ErpsPhyRingWestMepIdDeleted, sle2ErpsInstPhyRingAdded, sle2ErpsInstPhyRingDeleted,
|
||
sle2ErpsInstProfileAdded, sle2ErpsInstProfileDeleted, sle2ErpsInstVitrualChannelAdded, sle2ErpsInstVitrualChannelDeleted, sle2ErpsInstNoneVirtualChannelAdded,
|
||
sle2ErpsInstNoneVirtualChannelDeleted, sle2ErpInstActiveChanged }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Description."
|
||
::= { sleFaultMgmt 20 }
|
||
|
||
|
||
|
||
END
|
||
|
||
--
|
||