mibs/MIBS/dasan/SLE-FAULTMGMT-MIB
2023-12-05 12:25:34 +01:00

26276 lines
746 KiB
Plaintext
Raw Blame History

--
-- sle-faultmgmt-mib.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
-- Tuesday, April 12, 2016 at 17:15:30
--
SLE-FAULTMGMT-MIB DEFINITIONS ::= BEGIN
IMPORTS
sleMgmt
FROM DASAN-SMI
SleControlStatusType, SleControlRequestResultType
FROM SLE-TC-MIB
OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TimeTicks, IpAddress, Integer32, Unsigned32, Gauge32,
Counter32, Counter64, BITS, OBJECT-TYPE, MODULE-IDENTITY,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
MacAddress, TimeStamp, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
sleFaultMgmt MODULE-IDENTITY
LAST-UPDATED "201008130000Z" -- August 13, 2010 at 00:00 GMT
ORGANIZATION
" DASAN Networks"
CONTACT-INFO
"
"
DESCRIPTION
"The MIB module representing multiple logical
entities for the SLE alarm management. "
REVISION "190412080000Z" -- December 08, 1904 at 00:00 GMT
DESCRIPTION
" "
::= { sleMgmt 4 }
--
-- Textual conventions
--
SpecificNum ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Description."
SYNTAX INTEGER
{
portDown(1),
portUp(2),
portRemoved(3),
portInstalled(4),
powerFail(5),
powerOK(6),
powerRemoved(7),
powerInstalled(8),
fanFail(9),
fanOK(10),
fanRemoved(11),
fanInstalled(12),
moduleRemoved(13),
moduleInstalled(14),
systemRestart(15),
systemStart(16),
broadcastOver(17),
broadcastUnder(18),
cpuOverLoad(19),
cpuUnderLoad(20),
memoryOverUsed(21),
memoryUnderUsed(22),
portOverThreshold(23),
portUnderThreshold(24),
temperatureHigh(25),
temperatureLow(26),
mfgdBlocked(27),
mfgdReleased(28),
ipConflict(29),
ipUnconflict(30),
dhcpLeaseShortage(31),
dhcpLeaseSufficient(32),
dhcpOccuredIllegalEntry(33),
dhcpRemovedIllegalEntry(34),
rmonAlarmRising(35),
rmonAlarmNoRising(36),
rmonAlarmFalling(37),
rmonAlarmNoFalling(38),
bpduGuardDisabled(39),
rootGuardDisabled(40),
portSecurity(41),
userLogin(42),
userLogout(43),
systemWarmStart(44),
igmpGroupJoined(51),
igmpGroupLeaved(52),
dhcpIpaddressBound(53),
dhcpIpaddressFree(54),
doorOpened(55),
doorClosed(56),
powerModeChangedPowerToBattery(57),
powerModeChangedBatteryToPower(58),
batterylowcapacity(59),
batterynormalcapacity(60),
batteryhighTemperature(61),
batterynormalTemperature(62),
authenticationFail(63),
authenticationNoFail(64),
psuAcHighTemperature(65),
psuAcNormalTemperature(66),
batteryRemoved(67),
batteryEquipped(68),
batteryLowVoltage(69),
batteryNormalVoltage(70),
adminAccessLogin(71),
adminAccessLogout(72),
cfgdBlocked(73),
cfgdReleased(74),
sfgdBlocked(75),
sfgdReleased(76),
swWatchdogAbnomalState(77),
swWatchdogNomalState(78),
swWatchdogDetectError(79),
swWatchdogClearError(80),
ppsControlBlocked(81),
ppsControlReleased(82),
gotDMITempHighOverAlarm(83),
gotDMITempHighFallAlarm(84),
gotDMITempLowOverAlarm(85),
gotDMITempLowFallAlarm(86),
gotDMITempHighOverWarning(87),
gotDMITempHighFallWarning(88),
gotDMITempLowOverWarning(89),
gotDMITempLowFallWarning(90),
gotDMIVolHighOverAlarm(91),
gotDMIVolHighFallAlarm(92),
gotDMIVolLowOverAlarm(93),
gotDMIVolLowFallAlarm(94),
gotDMIVolHighOverWarning(95),
gotDMIVolHighFallWarning(96),
gotDMIVolLowOverWarning(97),
gotDMIVolLowFallWarning(98),
gotDMITxBiasHighOverAlarm(99),
gotDMITxBiasHighFallAlarm(100),
gotDMITxBiasLowOverAlarm(101),
gotDMITxBiasLowFallAlarm(102),
gotDMITxBiasHighOverWarning(103),
gotDMITxBiasHighFallWarning(104),
gotDMITxBiasLowOverWarning(105),
gotDMITxBiasLowFallWarning(106),
gotDMITxPowerHighOverAlarm(107),
gotDMITxPowerHighFallAlarm(108),
gotDMITxPowerLowOverAlarm(109),
gotDMITxPowerLowFallAlarm(110),
gotDMITxPowerHighOverWarning(111),
gotDMITxPowerHighFallWarning(112),
gotDMITxPowerLowOverWarning(113),
gotDMITxPowerLowFallWarning(114),
gotDMIRxPowerHighOverAlarm(115),
gotDMIRxPowerHighFallAlarm(116),
gotDMIRxPowerLowOverAlarm(117),
gotDMIRxPowerLowFallAlarm(118),
gotDMIRxPowerHighOverWarning(119),
gotDMIRxPowerHighFallWarning(120),
gotDMIRxPowerLowOverWarning(121),
gotDMIRxPowerLowFallWarning(122),
nosRemoteUpgradeRequest(123),
nosRemoteUpgradeSuccess(124),
nosRemoteUpgradeFailAbort(125),
nosRemoteUpgradeFailHeaderError(126),
nosRemoteUpgradeFailDownloadError(127),
nosRemoteUpgradeFailFlashError(128),
nosRemoteUpgradeStart(129),
systemDyingGasp(130),
remoteOamDyingGasp(131),
remoteOamDyingGaspRestoration(132),
cliHistory(133),
cliHistoryNo(134),
ntpConnectionFail(135),
nmsConnectionTypeChanged(137),
fanSpeedFallUnderThreshold(138),
fanSpeedRisingOverThreshold(139),
userLoginFail(140),
temperatureHighContinued(142),
swWatchdogInetAbnormalState(150),
swWatchdogInetNormalState(151),
swWatchdogInetDetectError(152),
swWatchdogInetClearError(153),
swWatchdogPonAbnormalState(154),
swWatchdogPonNormalState(155),
swWatchdogPonDetectError(156),
swWatchdogPonClearError(157),
arpInspectInvalid(158),
clockModuleRemoved(159),
clockModuleInstalled(160),
clockModuleInitFail(161),
clockModuleInitOk(162),
cliHistoryLog(163),
cliHistoryLogNo(164),
slotActionEvent(165),
slotStateChange(166),
interfaceAdminDown(167),
interfaceAdminUp(168),
slotPowerMonAbnormal(169),
slotPowerMonNormal(170),
slotErrorLEDChanged(171),
bfdSessionStateChanged(172),
clockModuleOPModeChanged(173),
clockModuleRefChanged(174),
clockModuleInSrcStatusChanged(175),
clockModuleInSrcAISStatusChanged(176),
clockModuleInSrcLoSStatusChanged(177),
clockModuleInSrcLSDCStatusChanged(178),
clockModuleInSrcNtrClockChanged(179),
portRxOverThreshold(181),
portRxUnderThreshold(182),
portTxOverThreshold(183),
portTxUnderThreshold(184),
cpuPpsOverThreshold(185),
cpuPpsUnderThreshold(186),
pairFanPowerOff(191),
pairFanPowerOn(192),
slotHealthStatusTimeout(199),
slotHealthStatusTimeoutCleared(200),
advaTemperature(201),
advaTemperatureNo(202),
advaPSUFailure(203),
advaPSUFailureNo(204),
advaFanFailure(205),
advaFanFailureNo(206),
advaInterfaceReceiveFailure(207),
advaInterfaceReceiveFailureNo(208),
advaInterfaceOpticalThreshold(209),
advaInterfaceOpticalThresholdNo(210),
advaInterfaceTransmitFault(211),
advaInterfaceTransmitFaultNo(212),
advaInterfaceMisconfiguration(213),
advaInterfaceMisconfigurationNo(214),
advaInterfaceSFPMismatch(215),
advaInterfaceSFPMismatchNo(216),
advaVoltageLow(217),
advaVoltageLowNo(218),
advaVoltageHigh(219),
advaVoltageHighNo(220),
criticalAlarmLedOn(251),
criticalAlarmLedOff(252),
majorAlarmLedOn(253),
majorAlarmLedOff(254),
minorAlarmLedOn(255),
minorAlarmLedOff(256),
systemTemperPowerCutOff(291),
systemTemperPowerCutoffCleared(292),
slotTemperPowerCutOff(294),
erpDomainLotp(301),
erpDomainLotpNo(302),
erpDomainULotp(303),
erpDomainULotpNo(304),
erpDomainMultipleRM(305),
erpDomainMultipleRMNo(306),
erpDomainRMNodeReacheablity(307),
erpDomainRMNodeReacheablityNo(308),
startupConfigLoadEnded(391),
eponOnuDeregister(401),
eponOnuRegister(402),
eponOnuRegistrationError(403),
eponOnuNoRegistrationError(404),
eponBadEncryptionKey(405),
eponNoBadEncryptionKey(406),
eponLlidMistmatch(407),
eponNoLlidMismatch(408),
eponTooManyRegister(409),
eponNoTooManyRegister(410),
eponDyingGASP(411),
eponNoDyingGASP(412),
eponOnuErrFramePeriod(413),
eponOnuNoErrFramePeriod(414),
eponOnuErrFrame(415),
eponOnuNoErrFrame(416),
eponOnuErrFrameSecondSummary(417),
eponOnuNoErrFrameSecondSummary(418),
eponOnuLastOnuDeregister(419),
eponOnuNoLastOnuDeregister(420),
eponOltCableDown(421),
eponOltRecoverCableDown(422),
eponOltHealthCheckError(423),
eponOnuOpticSignalErr(424),
eponOnuRecoverOpticSignalErr(425),
standardLinkFault(428),
standardLinkFaultCleared(429),
lossOfSignal(430),
lossOfSignalCleared(431),
transmitFail(432),
transmitFailCleared(433),
macLearningOverflow(434),
macLearningOverflowCleared(435),
loopback(436),
loopbackCleared(437),
standardDyinggasp(438),
standardDyinggaspCleared(439),
externalDyinggasp(440),
externalDyinggaspCleared(441),
standardCriticalEvent(442),
standardCriticalEventCleared(443),
externalCriticalEvent(444),
externalCriticalEventCleared(445),
eponStandbyLos(446),
eponStandbyLosCleared(447),
eponOnuPingTest(448),
eponOnuDmiThresholdTemperOverHighWarn(450),
clearEponOnuDmiThresholdTemperOverHighWarn(451),
eponOnuDmiThresholdTemperFallLowWarn(452),
clearEponOnuDmiThresholdTemperFallLowWarn(453),
eponOnuDmiThresholdTemperOverHighAlarm(454),
clearEponOnuDmiThresholdTemperOverHighAlarm(455),
eponOnuDmiThresholdTemperFallLowAlarm(456),
clearEponOnuDmiThresholdTemperFallLowAlarm(457),
eponOnuDmiThresholdVoltageOverHighWarn(458),
clearEponOnuDmiThresholdVoltageOverHighWarn(459),
eponOnuDmiThresholdVoltageFallLowWarn(460),
clearEponOnuDmiThresholdVoltageFallLowWarn(461),
eponOnuDmiThresholdVoltageOverHighAlarm(462),
clearEponOnuDmiThresholdVoltageOverHighAlarm(463),
eponOnuDmiThresholdVoltageFallLowAlarm(464),
clearEponOnuDmiThresholdVoltageFallLowAlarm(465),
eponOnuDmiThresholdTxbiasOverHighWarn(466),
clearEponOnuDmiThresholdTxbiasOverHighWarn(467),
eponOnuDmiThresholdTxbiasFallLowWarn(468),
clearEponOnuDmiThresholdTxbiasFallLowWarn(469),
eponOnuDmiThresholdTxbiasOverHighAlarm(470),
clearEponOnuDmiThresholdTxbiasOverHighAlarm(471),
eponOnuDmiThresholdTxbiasFallLowAlarm(472),
clearEponOnuDmiThresholdTxbiasFallLowAlarm(473),
eponOnuDmiThresholdTxpowerOverHighWarn(474),
clearEponOnuDmiThresholdTxpowerOverHighWarn(475),
eponOnuDmiThresholdTxpowerFallLowWarn(476),
clearEponOnuDmiThresholdTxpowerFallLowWarn(477),
eponOnuDmiThresholdTxpowerOverHighAlarm(478),
clearEponOnuDmiThresholdTxpowerOverHighAlarm(479),
eponOnuDmiThresholdTxpowerFallLowAlarm(480),
clearEponOnuDmiThresholdTxpowerFallLowAlarm(481),
eponOnuDmiThresholdRxpowerOverHighWarn(482),
clearEponOnuDmiThresholdRxpowerOverHighWarn(483),
eponOnuDmiThresholdRxpowerFallLowWarn(484),
clearEponOnuDmiThresholdRxpowerFallLowWarn(485),
eponOnuDmiThresholdRxpowerOverHighAlarm(486),
clearEponOnuDmiThresholdRxpowerOverHighAlarm(487),
eponOnuDmiThresholdRxpowerFallLowAlarm(488),
clearEponOnuDmiThresholdRxpowerFallLowAlarm(489),
eponDetectRouge(490),
clearEpoonDetectRouge(491),
eponDetectRougeOnuPowerOff(492),
eponDetectRougeOnuPowerOffFailed(493),
eponDetectRougeOnuDeregisterSuccess(494),
eponDetectRougeOnuDeregisterFailed(495),
eponDetectRougeOnuFoundFailed(496),
eponOltRedundancyDetectRxpower(497),
clearEponOltRedundancyDetectRxpower(498),
eponOltRedundancySwitchoverReasonForce(499),
eponOltRedundancySwitchoverReasonLos(500),
autoCLIStart(501),
autoCLINoStart(502),
autoCLIComplete(503),
autoCLINoComplete(504),
autoCLIRemoveOutputFile(505),
autoCLINoRemoveOutputFile(506),
autoResetSystem(507),
autoResetNoSystem(508),
autoResetPingReplyLoss(509),
autoResetNoPingReplyLoss(510),
autoResetMemoryLeakDetect(511),
autoResetNoMemoryLeakDetect(512),
loopDetectBlocked(551),
loopDetectUnBlockedByExpireTimer(552),
loopDetectUnBlockedByLinkDown(553),
loopDetectUnBlockedByClearCmd(554),
oamRemoteTestLoopback(562),
arulePacketDropDetect(601),
arulePacketDropRelease(602),
autoCpeUpgradeStart(605),
autoCpeUpgradeFail(607),
autoCpeUpgradeSuccess(609),
batteryUnderTemper(611),
batteryTemperUnderToNormal(612),
batteryCellAbnormal(613),
batteryCellNormal(614),
batteryCellTestChargeStarted(615),
batteryCellTestChargeFinished(616),
batteryAcPowerFault(617),
batteryAcPowerOk(618),
bME1CardNoDetect(620),
clearBME1CardNoDetect(621),
bME1CardAFEerror(622),
clearBME1CardAFEerror(623),
bME1CardIFEerror(624),
clearBME1CardIFEerror(625),
bME1CardFWerror(626),
clearBME1CardFWerror(627),
bME1CardPROVerror(628),
clearBME1CardPROVerror(629),
bME1CrashDetect(630),
clearBME1CrashDetect(631),
bME2CardNoDetect(632),
clearBME2CardNoDetect(633),
bME2CardAFEerror(634),
clearBME2CardAFEerror(635),
bME2CardIFEerror(636),
clearBME2CardIFEerror(637),
bME2CardFWerror(638),
clearBME2CardFWerror(639),
bME2CardPROVerror(640),
clearBME2CardPROVerror(641),
bME2CrashDetect(642),
clearBME2CrashDetect(643),
bME3CardNoDetect(644),
clearBME3CardNoDetect(645),
bME3CardAFEerror(646),
clearBME3CardAFEerror(647),
bME3CardIFEerror(648),
clearBME3CardIFEerror(649),
bME3CardFWerror(650),
clearBME3CardFWerror(651),
bME3CardPROVerror(652),
clearBME3CardPROVerror(653),
bME3CrashDetect(654),
clearBME3CrashDetect(655),
powerFromBattery(656),
clearPowerFromBattery(657),
invalidBatteryStatus(658),
clearInvalidBatteryStatus(659),
batteryChargeLow(660),
clearBatteryChargeLow(661),
batteryNotPresent(662),
clearBatteryNotPresent(663),
voltageLow(664),
clearVoltageLow(665),
tempOverThreshold(666),
clearTempOverThreshold(667),
tempUnderThreshold(668),
clearTempUnderThreshold(669),
cpuOverThreshold(670),
clearCpuOverThreshold(671),
trafficOverload(672),
clearTrafficOverload(673),
gEPONModuleNotDetect(674),
clearGEPONModuleNotDetect(675),
gEPONPortOperationDown(676),
clearGEPONPortOperationDown(677),
gEPONNoIncomingTraffic(678),
clearGEPONNoIncomingTraffic(679),
processCrashDetect(680),
clearProcessCrashDetect(681),
memoryLeakDetect(682),
clearMemoryLeakDetect(683),
memoryCorrupDetect(684),
clearMemoryCorrupDetect(685),
memoryLowDetect(686),
clearMemoryLowDetect(687),
dataLineerror(688),
clearDataLineerror(689),
addressLineerror(690),
clearAddressLineerror(691),
chipsetNotDetcet(692),
clearChipsetNotDetcet(693),
pciBuserror(694),
clearPciBuserror(695),
securityAdminConnect(696),
clearSecurityAdminConnect(697),
oNUPowerDown(698),
clearONUPowerDown(699),
oNUNotRegister(700),
clearONUNotRegister(701),
oNTOpticPre(702),
clearONTOpticPre(703),
writeMemroyFailSeveralTimes(721),
writeMemroyFailSeveralTimesCleared(722),
switchoverInitiated(800),
switchoverDone(801),
boardChangeState(802),
redConfigurationMisMatch(803),
aiuAlarmInput1(851),
aiuAlarmInput1Cleared(852),
aiuAlarmInput2(853),
aiuAlarmInput2Cleared(854),
aiuAlarmInput3(855),
aiuAlarmInput3Cleared(856),
aiuAlarmInput4(857),
aiuAlarmInput4Cleared(858),
aiuSlotUninstalled(859),
aiuSlotInstalled(860),
gponNoAuthCBU(901),
gponDuplicateONU(902),
gponDyingGasp(903),
gponUpgradeComplete(904),
gponDeregistered(905),
gponRegistered(906),
gponRogueOnu(907),
gponOnuBatteryEvent(908),
clearGponOnuBetteryEvent(909),
gponOnuPortOperStatus(910),
gponTransceiverChanged(911),
gponOltLosOn(912),
gponOltLosOff(913),
gponOltLosiOn(914),
gponOltLosiOff(915),
gponDyingGaspOn(916),
gponDyingGaspOff(917),
gponOntOSUpgradeStatus(918),
gponOntBLUpgradeStatus(919),
gponOltRxPowerLoss(920),
gponOltRxPowerDetected(921),
gponOnuTemperatureHighOverThreshold(922),
gponOnuTemperatureHighFallThreshold(923),
gponOnuTemperatureLowOverThreshold(924),
gponOnuTemperatureLowFallThreshold(925),
gponOnuCpuOverThreshold(926),
gponOnuCpuFallThreshold(927),
gponOnuMemoryOverThreshold(928),
gponOnuMemoryFallThreshold(929),
gponOnuI2cFail(930),
gponOnuRxOpticLowThreshAlarmOn(931),
gponOnuRxOpticLowThreshAlarmOff(932),
gponOnuRxOpticHighThreshAlarmOn(933),
gponOnuRxOpticHighThreshAlarmOff(934),
gponOltLOFIOn(935),
gponOltLOFIOff(936),
gponOltDOWOn(937),
gponOltDOWOff(938),
gponOltSFOn(939),
gponOltSFOff(940),
gponOltSDOn(941),
gponOltSDOff(942),
gponOltLCDGIOn(943),
gponOltLCDGIOff(944),
gponOltRDOn(945),
gponOltRDOff(946),
gponOltSUFOn(947),
gponOltSUFOff(948),
gponOltLOAOn(949),
gponOltLOAOff(950),
gponOltLOAMIOn(951),
gponOltLOAMIOff(952),
gponOltMEMOn(953),
gponOltMEMOff(954),
gponOltPEEOn(955),
gponOltPEEOff(956),
gponOltPSTOn(957),
gponOltPSTOff(958),
gponOltERROn(959),
gponOltERROff(960),
gponOltREIOn(961),
gponOltREIOff(962),
gponAntiSpoofingDupPortOn(963),
gponAntiSpoofingDupPortOff(964),
gponRedundancySwitchOver(965),
gponDuplicatedRangingResponse(966),
gponOnuPortOpticModuleRemove(967),
gponOnuPortOpticModuleInstall(968),
gponOnuOMCCProblemDetected(969),
gponOnuOMCCProblemCleared(970),
gponOltFixedTcontAlarmOn(971),
gponOltFixedTcontAlarmOff(972),
gponOltDynamicTcontAlarmOn(973),
gponOltDynamicTcontAlarmOff(974),
gponOltPortCountAlarmOn(975),
gponOltPortCountAlarmOff(976),
gponOltCableDownAlarmOn(977),
gponOltCableDownAlarmOff(978),
gponOltDeactiveMonitorAlarmOn(979),
gponOltDeactiveMonitorAlarmOff(980),
gponOltDfiOn(981),
gponOltDfiOff(982),
gponOltTransceiverPortChanged(984),
gponOnuPortOperStatusDown(985),
gponOnuPortOperStatusUp(986),
gponOltRxPowerHighOver(987),
gponOltRxPowerHighCleared(988),
gponOltRxPowerLowUnder(989),
gponOltRxPowerLowCleared(990),
oamRapsEastPortStatusChanged(1001),
oamRapsWestPortStatusChanged(1002),
oamURNodePortStatusChanged(1003),
oamRemoteLlcfLinkDown(1008),
oamRemoteLlcfLinkUp(1009),
oamInterfaceStatusChanged(1010),
oamMepRDIDetected(1011),
oamMepRDICleared(1012),
oamMepLOCDetected(1013),
oamMepLOCCleared(1014),
oamMepUNPDetected(1015),
oamMepUNPCleared(1016),
oamMepUNMDetected(1017),
oamMepUNMCleared(1018),
oamMepMMGDetected(1019),
oamMepMMGCleared(1020),
oamMepUNLDetected(1021),
oamMepUNLCleared(1022),
oamMepAISDetected(1023),
oamMepAISCleared(1024),
oamMepLCKDetected(1025),
oamMepLCKCleared(1026),
oamMepMISSINGDetected(1027),
oamMepMISSINGCleared(1028),
voipPortStatusEnabled(1051),
voipPortStatusDisabled(1052),
emLogDefectCPUHighOver(1101),
emLogDefectCPUHighUnder(1102),
emLogTemperHighOver(1103),
emLogTemperHighUnder(1104),
emLogTemperLowUnder(1105),
emLogTemperLowOver(1106),
emLogMemLowUnder(1107),
emLogMemLowOver(1108),
emLogFanFail(1109),
emLogFanFailCleared(1110),
emLogPhyCRCFail(1111),
emLogPhyCRCFailCleared(1112),
emLogPhyDetectFail(1113),
emLogPhyDetectFailCleared(1114),
emLogSFUMateInitFail(1115),
emLogSFUMateInitFailCleared(1116),
emLogDaemonHealthBad(1117),
emLogDaemonHealthBadCleared(1118),
emLogGPIURavenLinkDown(1119),
emLogGPIURavenLinkDownCleared(1120),
emLogRPMLow(1121),
emLogRPMLowCleared(1122),
emLogNAKError(1123),
emLogNAKErrorCleared(1124),
snmpAllConfCleared(1141),
slotNosUpgradeStart(1151),
slotNosUpgradeEnd(1152),
autonegoMissmatedSpeed(1171),
autonegoMissmatedDuplex(1172),
autonegoMismatched(1174),
dmiTempHighOverDurationAlarmOld(1201),
dmiTempLowFallDurationAlarmOld(1202),
dmiTempHighOverDurationWarningOld(1203),
dmiTempLowFallDurationWarningOld(1204),
dmiVolHighOverDurationAlarmOld(1205),
dmiVolLowFallDurationAlarmOld(1206),
dmiVolHighOverDurationWarningOld(1207),
dmiVolLowFallDurationWarningOld(1208),
dmiTxBiasHighOverDurationAlarmOld(1209),
dmiTxBiasLowFallDurationAlarmOld(1210),
dmiTxBiasHighOverDurationWarningOld(1211),
dmiTxBiasLowFallDurationWarningOld(1212),
dmiTxPowerHighOverDurationAlarmOld(1213),
dmiTxPowerLowFallDurationAlarmOld(1214),
dmiTxPowerHighOverDurationWarningOld(1215),
dmiTxPowerLowFallDurationWarningOld(1216),
dmiRxPowerHighOverDurationAlarmOld(1217),
dmiRxPowerLowFallDurationAlarmOld(1218),
dmiRxPowerHighOverDurationWarningOld(1219),
dmiRxPowerLowFallDurationWarningOld(1220),
attackGuard(1221),
attackGuardNo(1222),
activeLinkDown(1223),
activeLinkDownNo(1224),
activeLinkUp(1225),
activeLinkUpNo(1226),
redundantLinkDown(1227),
redundantLinkDownNo(1228),
redundantLinkUp(1229),
redundantLinkUpNo(1230),
inputErrorThreshold(1231),
inputErrorThresholdNo(1232),
overSizeFrameThreshold(1233),
overSizeFrameThresholdNo(1234),
configLoadFail(1235),
configLoadFailNo(1236),
nosLoadFail(1237),
nosLoadFailNo(1238),
securityViolation(1239),
securityViolationNo(1240),
selfTestCompleted(1241),
selfTestCompletedNo(1242),
risingAlarm(1243),
risingAlarmNo(1244),
fallingAlarm(1245),
fallingAlarmNo(1246),
newRoot(1247),
newRootNo(1248),
topologyChange(1249),
topologyChangeNo(1250),
broadcastStormStart(1251),
broadcastStormStartNo(1252),
broadcastStormEnd(1253),
broadcastStormEndNo(1254),
duplicateMac(1255),
duplicateMacNo(1256),
trapLog(1257),
trapLogNo(1258),
scriptLoadFail(1259),
scriptLoadFailNo(1260),
monitorEvent(1261),
monitorEventNo(1262),
powerDetectFail(1263),
powerDetectOk(1264),
underSizeFrameThreshold(1265),
underSizeFrameThresholdNo(1266),
runtFrameThreshold(1267),
runtFrameThresholdNo(1268),
dyingGasp(1269),
dyingGaspNo(1270),
voipPortStatusEnable(1271),
voipPortStatusDisable(1272),
fanStop(1281),
fanRun(1282),
mllcfLinkDown(1301),
mllcfLinkUp(1302),
gponOnuAniVoltageLowThreshAlarmOn(1331),
gponOnuAniVoltageLowThreshAlarmOff(1332),
gponOnuAniVoltageHighThreshAlarmOn(1333),
gponOnuAniVoltageHighThreshAlarmOff(1334),
gponOnuAniTemperatureLowThreshAlarmOn(1335),
gponOnuAniTemperatureLowThreshAlarmOff(1336),
gponOnuAniTemperatureHighThreshAlarmOn(1337),
gponOnuAniTemperatureHighThreshAlarmOff(1338),
gponOnuAniTxBiasLowThreshAlarmOn(1339),
gponOnuAniTxBiasLowThreshAlarmOff(1340),
gponOnuAniTxBiasHighThreshAlarmOn(1341),
gponOnuAniTxBiasHighThreshAlarmOff(1342),
gponOnuAniTxpowerLowThreshAlarmOn(1343),
gponOnuAniTxpowerLowThreshAlarmOff(1344),
gponOnuAniTxpowerHighThreshAlarmOn(1345),
gponOnuAniTxpowerHighThreshAlarmOff(1346),
gponOnuServiceOpModeAlarm(1347),
gponOnuServiceOpModeAlarmCleared(1348),
gponOnuAuthErrorReasonUpdated(1350),
portThresholdTxOverAlarm(1351),
portThresholdTxOverAlarmCleared(1352),
portThresholdTxOverWarn(1353),
portThresholdTxOverWarnCleared(1354),
portThresholdRxOverAlarm(1355),
portThresholdRxOverAlarmCleared(1356),
portThresholdRxOverWarn(1357),
portThresholdRxOverWarnCleared(1358),
tempThresholdHighOverAlarm(1361),
tempThresholdHighOverAlarmCleared(1362),
tempThresholdLowOverAlarm(1363),
tempThresholdLowOverAlarmCleared(1364),
tempThresholdHighOverWarn(1365),
tempThresholdHighOverWarnCleared(1366),
tempThresholdLowOverWarn(1367),
tempThresholdLowOverWarnCleared(1368),
moduleDmiReadError(1381),
moduleDmiReadErrorCleared(1382),
stormControlRxOver(1391),
stormControlRxOverCleared(1392),
rmonCrcAlignErrorRising(1401),
rmonCrcAlignErrorRisingCleared(1402),
rmonJabberRising(1403),
rmonJabberRisingCleared(1404),
rmonOversizePacketRising(1405),
rmonOversizePacketRisingCleared(1406),
rmonUndersizePacketRising(1407),
rmonUndersizePacketRisingCleared(1408),
rmonFragmentRising(1409),
rmonFragmentRisingCleared(1410),
rmonDropEventRising(1411),
rmonDropEventRisingCleared(1412),
rmonCollisionRising(1413),
rmonCollisionRisingCleared(1414),
rmonIfInDiscardsRising(1415),
rmonIfInDiscardsRisingCleared(1416),
rmonIfInErrosRising(1417),
rmonIfInErrosRisingCleared(1418),
rmonIfOutDiscardsRising(1419),
rmonIfOutDiscardsRisingCleared(1420),
rmonIfOutErrosRising(1421),
rmonIfOutErrosRisingCleared(1422),
rmonIfInPauseFrameRising(1423),
rmonIfInPauseFrameRisingCleared(1424),
rmonIfOutPauseFrameRising(1425),
rmonIfOutPauseFrameRisingCleared(1426),
rmonQueueTransmitRising(1427),
rmonQueueTransmitRisingCleared(1428),
rmonQueueDropRising(1429),
rmonQueueDropRisingCleared(1430),
eponOltRedundancySwitchoverReasonSlotRemove(1500),
eponOltRedundancySwitchoverReasonSlotRestart(1501),
eponOltRedundancySwitchoverReasonAutoDetect(1502),
eponOltRedundancySwitchoverReasonWtrDetect(1503),
eponOnuCrcUpStreamAlarmErr(1504),
eponOnuCrcUpStreamAlarmErrClean(1505),
eponOnuTooFrequentlyRegisteredErr(1506),
eponOnuTooFrequentlyRegisteredErrClean(1507),
eponOnuCrcDownStreamAlarmErr(1508),
eponOnuCrcDownStreamAlarmErrClean(1509),
eponOnuOpticPowerAlarmErr(1510),
eponOnuOpticPowerAlarmErrClean(1511),
eponOnuDcVoltageAlarmErr(1512),
eponOnuDcVoltageAlarmErrClean(1513),
eponOnuLoopingAlarmErr(1514),
eponOnuLoopingAlarmErrClean(1515),
eponOltRedundancyStandbyOltRxPowerOverHighThresholdAlarm(1516),
eponOltRedundancyStandbyOltRxPowerUnderLowThresholdAlarm(1517),
eponOnuBroadcastStormLlidUpAlarmErr(1518),
eponOnuBroadcastStormLlidUpAlarmErrClean(1519),
eponOnuBroadcastStormLlidDnAlarmErr(1520),
eponOnuBroadcastStormLlidDnAlarmErrClean(1521),
eponOnuBroadcastStormUniUpAlarmErr(1522),
eponOnuBroadcastStormUniUpAlarmErrClean(1523),
eponDetectRogueOnuTurn(1530),
eponDetectRogueOnuTurnClean(1531),
eponOnuLoopDetectErr(1532),
eponOnuRecoverDetectErr(1533),
eponThresholdAlarmLoopDetectErr(1534),
eponThresholdAlarmRecoverLoopDetectErr(1535),
eponThresholdAlarmOpticAlarmErr(1536),
eponThresholdAlarmRecoverOpticAlarmErr(1537),
eponThresholdAlarmOverVoltageErr(1538),
eponThresholdAlarmRecoverOverVoltageErr(1539),
eponOLTSFPModuleInstalled(1540),
eponOLTSFPModuleRemoved(1541),
eponOnuDailyRxPowerAlarm(1542),
fiberLengthChangedWarningAlarm(1561),
fiberLengthChangedWarningAlarmCleared(1562),
cfmOnuMepRdiCcmDetected(1601),
cfmOnuMepRdiCcmCleared(1602),
cfmOnuMepMacStatusDetected(1603),
cfmOnuMepMacStatusCleared(1604),
cfmOnuMepRemoteCcmDetected(1605),
cfmOnuMepRemoteCcmCleared(1606),
cfmOnuMepErrorCcmDetected(1607),
cfmOnuMepErrprCcmCleared(1608),
cfmOnuMepXconCcmDetected(1609),
cfmOnuMepXconCcmCleared(1610),
cfmOnuMepUnexpectedPeriodDetected(1611),
cfmOnuMepUnexpectedPeriodCleared(1612),
cfmOnuMepAisDetected(1613),
cfmOnuMepAisCleared(1614),
tcpDosAttack(2001),
tcpDosAttackCleared(2002),
tcpPortFlooding(2003),
tcpPortFloodingCleared(2004),
tcpHostRandomFlooding(2005),
tcpHostRandomFloodingCleared(2006),
tcpHostScanning(2007),
tcpHostScanningCleared(2008),
ipSppfing(2009),
ipSppfingCleared(2010),
udpDosAttack(2011),
udpDosAttackCleared(2012),
udpPortFlooding(2013),
udpPortFloodingCleared(2014),
udpHostRandomFlooding(2015),
udpHostRandomFloodingCleared(2016),
udpHostScanning(2017),
udpHostScanningCleared(2018),
udpIPSppfing(2019),
udpIPSppfingCleared(2020),
icmpDosAttack(2021),
icmpDosAttackCleared(2022),
icmpIPSppfing(2023),
icmpIPSppfingCleared(2024),
icmpHostScanning(2025),
icmpHostScanningCleared(2026),
arpMacFlooding(2027),
arpMacFloodingCleared(2028),
arpSpoofing(2029),
arpSpoofingCleared(2030),
decoySnare(2031),
decoySnareCleared(2032),
hostScan(2033),
hostScanCleared(2034),
portScan(2035),
portScanCleared(2036),
tcpPortScanning(2037),
tcpPortScanningCleared(2038),
udpPortScanning(2039),
udpPortScanningCleared(2040),
staticAttack(2041),
staticAttackCleared(2042),
dmiTempHighOverDurationAlarm(2101),
dmiTempHighOverDurationAlarmCleared(2102),
dmiTempLowOverDurationAlarm(2103),
dmiTempLowOverDurationAlarmCleared(2104),
dmiTempHighOverDurationWarning(2105),
dmiTempHighOverDurationWarningCleared(2106),
dmiTempLowOverDurationWarning(2107),
dmiTempLowOverDurationWarningCleared(2108),
dmiVolHighOverDurationAlarm(2109),
dmiVolHighOverDurationAlarmCleared(2110),
dmiVolLowOverDurationAlarm(2111),
dmiVolLowOverDurationAlarmCleared(2112),
dmiVolHighOverDurationWarning(2113),
dmiVolHighOverDurationWarningCleared(2114),
dmiVolLowOverDurationWarning(2115),
dmiVolLowOverDurationWarningCleared(2116),
dmiTxBiasHighOverDurationAlarm(2117),
dmiTxBiasHighOverDurationAlarmCleared(2118),
dmiTxBiasLowOverDurationAlarm(2119),
dmiTxBiasLowOverDurationAlarmCleared(2120),
dmiTxBiasHighOverDurationWarning(2121),
dmiTxBiasHighOverDurationWarningCleared(2122),
dmiTxBiasLowOverDurationWarning(2123),
dmiTxBiasLowOverDurationWarningCleared(2124),
dmiTxPowerHighOverDurationAlarm(2125),
dmiTxPowerHighOverDurationAlarmCleared(2126),
dmiTxPowerLowOverDurationAlarm(2127),
dmiTxPowerLowOverDurationAlarmCleared(2128),
dmiTxPowerHighOverDurationWarning(2129),
dmiTxPowerHighOverDurationWarningCleared(2130),
dmiTxPowerLowOverDurationWarning(2131),
dmiTxPowerLowOverDurationWarningCleared(2132),
dmiRxPowerHighOverDurationAlarm(2133),
dmiRxPowerHighOverDurationAlarmCleared(2134),
dmiRxPowerLowOverDurationAlarm(2135),
dmiRxPowerLowOverDurationAlarmCleared(2136),
dmiRxPowerHighOverDurationWarning(2137),
dmiRxPowerHighOverDurationWarningCleared(2138),
dmiRxPowerLowOverDurationWarning(2139),
dmiRxPowerLowOverDurationWarningCleared(2140),
reloadMateInitiated(2201),
reloadMateDone(2202),
reloadSIUInitiated(2203),
reloadSIUDone(2204)
}
--
-- Node definitions
--
sleFaultMgmtBase OBJECT IDENTIFIER ::= { sleFaultMgmt 1 }
sleFaultMgmtBaseGroup OBJECT IDENTIFIER ::= { sleFaultMgmtBase 1 }
sleFaultDefaultSeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleFaultMgmtBaseGroup 1 }
sleFaultCriteriaSeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleFaultMgmtBaseGroup 2 }
sleFaultNotifiyActivity OBJECT-TYPE
SYNTAX INTEGER
{
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleFaultMgmtBaseGroup 3 }
sleFaultNextSeqNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sequence number for the alarm synchronization.
This value has a number to be used for the next alarm trap."
::= { sleFaultMgmtBaseGroup 4 }
sleFaultMgmtBaseControl OBJECT IDENTIFIER ::= { sleFaultMgmtBase 2 }
sleFaultControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setAlarmDefaultSeverity(1),
setAlarmCriteriaSeverity(2),
setNotificationActivity(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This attribute identifies the control commands.
updateAlarmList:
the NE updates entries of alarms in the sleAlarmListTable
after having changed alarm severities of alarms
(due to change profile pointers in
managed entities or after modification of alarm severities
in profiles). This command should be applied once after having
finisled modifications of severties.
modifyAlarmSeverity:
modifies the severity of an alarm in specific profile.
createAlarmSeverityProfile:
creates a new profile with default severities.
The severities then have to be modified with command changeAlarmSeverity.
deleteAlarmSeverityProfile:
deletes a profile. Profile 1 is not allowed to be deleted.
Notifications : none "
::= { sleFaultMgmtBaseControl 1 }
sleFaultControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleFaultMgmtBaseControl 2 }
sleFaultControlTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleFaultMgmtBaseControl 3 }
sleFaultControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleFaultMgmtBaseControl 4 }
sleFaultControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleFaultMgmtBaseControl 5 }
sleFaultControlDefaultSeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleFaultMgmtBaseControl 6 }
sleFaultControlCriteriaSeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleFaultMgmtBaseControl 7 }
sleFaultControlNotifiyActivity OBJECT-TYPE
SYNTAX INTEGER
{
diabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleFaultMgmtBaseControl 8 }
sleFaultMgmtBaseNotification OBJECT IDENTIFIER ::= { sleFaultMgmtBase 3 }
sleAlarmDefaultSeverityChanged NOTIFICATION-TYPE
OBJECTS { sleFaultDefaultSeverity, sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMgmtBaseNotification 1 }
sleAlarmDefaultCriteriaChanged NOTIFICATION-TYPE
OBJECTS { sleFaultCriteriaSeverity, sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMgmtBaseNotification 2 }
sleNotificationActivityChanged NOTIFICATION-TYPE
OBJECTS { sleFaultControlRequest, sleFaultControlTimeStamp, sleFaultControlReqResult, sleFaultNotifiyActivity }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMgmtBaseNotification 3 }
sleAlarmSeverity OBJECT IDENTIFIER ::= { sleFaultMgmt 2 }
sleAlarmSeverityTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAlarmSeverityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The alarm severity table.
The alarm severity table associates
profile index and AlarmID pairs with severities to be
used for alarm traps.
(Note that this table does not apply to cleared alarms). "
::= { sleAlarmSeverity 1 }
sleAlarmSeverityEntry OBJECT-TYPE
SYNTAX SleAlarmSeverityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Entry of the alarm severity table. "
INDEX { sleAlarmSeverityIndex }
::= { sleAlarmSeverityTable 1 }
SleAlarmSeverityEntry ::=
SEQUENCE {
sleAlarmSeverityIndex
SpecificNum,
sleAlarmSeverityValue
INTEGER
}
sleAlarmSeverityIndex OBJECT-TYPE
SYNTAX SpecificNum
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following alarms is devided by the specific character, ===============.
The division basis is that alarms is bounded or released.
001: portDown: To detect whether physical or logical interface's link status is up or down.
002: portUp:
===============
003: portRemoved: To detect whether physical interface is installed or not.
004: portInstalled:
===============
005: powerFail: To detect whether power module's operation status is good or not.
(Without doubt, more than 1 power module should be equipped.)
006: powerOK:
===============
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
(Without doubt, more than 1 power module should be equipped.)
008: powerInstalled:
===============
009: fanFail: To detect whether FAN module's operation status is good or not.
010: fanOK:
===============
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
012: fanInstalled:
===============
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
014: moduleInstalled:
===============
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
===============
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
(This alarm isn<73><6E>t used current)
===============
017: broadcastOver: To detect the receipt of broadcast packet.
(This alarm isn<73><6E>t used current)
018: broadcastUnder:
===============
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
020: cpuUnderLoad:
===============
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
022: memoryUnderUsed:
===============
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
less than delta value of current interface's InOctects or not.
024: portUnderThreshold:
===============
025: temperatureHigh: To detect whether the configured system's temperature threshold is
less than current temperature or not.
026: temperatureLow:
===============
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
028: mfgdReleased:
===============
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
030: ipUnconflict:
===============
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
sufficient or not.
032: dhcpLeaseSufficient:
===============
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
034: dhcpRemovedIllegalEntry:
===============
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not. But alarm generation
would be issued by means of event type in RMON event.
036: rmonAlarmNoRising:
===============
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not.
But alarm generation would be issued by means of event type in RMON event.
038: rmonAlarmNoFalling:
===============
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
So STP reconfiguration doesn't use this edge ports.
===============
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So, Root guard prevents a new inserted node from being root bridge as well as
receiving a superior BPDU from root bridge.
but this node participates in STP topology reconfiguration.
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
===============
041: portSecurity: To detect whether interface is configured for security or not.
This can be used to prevent MAC from flooding as well as spoofing.
That is, As a result, this will obstruct an attack as like DoS attack.
===============
042: userLogin:
043: userLogout:
===============
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
052: igmpGroupLeaved:
===============
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
054: dhcpIpaddressFree:
===============
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
056: doorClosed:
===============
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
A system is using AC power usually.
If there is any power problems as like a power failure,
a system is using battery instead of AC power.
058: powerModeChangedBatteryToPower:
===============
059: batterylowcapacity: To detect whether current battery capacity is less
capacity threshold according to battery usage or not.
The capacity of AC power is 16 voltage and battery is 20.
Capacity threshold is configured by H/W specification.
So operator can't change it.
060: batterynormalcapacity:
===============
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
062: batterynormalTemperature:
===============
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
064: authenticationNofail:
===============
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
greater than temperature threshold or not.
066: psuAcNormalTemperature:
===============
067: batteryRemoved: To detect whether battery is equipped at network system or not.
Battery is used as redundancy power service. So operator can decide the installation of battery.
068: batteryEquipped:
===============
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
12.5 volt value is configured by H/W specification. So operator can't change it.
070: batteryNormalVoltage:
===============
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
072: adminAccessLogout:
===============
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
074: cfgdReleased:
===============
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
076: sfgdReleased:
===============
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
078: swWatchdogNormalState:
===============
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
080: swWatchdogClearError:
===============
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
082: ppsControlReleased:
===============
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
084: gotDMITempHighFallAlarm:
===============
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
086: gotDMITempLowFallAlarm:
===============
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
088: gotDMITempHighFallWarning:
===============
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
090: gotDMITempLowFallWarning:
===============
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
092: gotDMIVolHighFallAlarm:
===============
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
094: gotDMIVolLowFallAlarm:
===============
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
096: gotDMIVolHighFallWarning:
===============
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
098: gotDMIVolLowFallWarning:
===============
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
100: gotDMITxBiasHighFallAlarm:
===============
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
102: gotDMITxBiasLowFallAlarm:
===============
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
104: gotDMITxBiasHighFallWarning:
===============
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
106: gotDMITxBiasLowFallWarning:
===============
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
108: gotDMITxPowerHighFallAlarm:
===============
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
110: gotDMITxPowerLowFallAlarm:
===============
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
112: gotDMITxPowerHighFallWarning:
===============
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
114: gotDMITxPowerLowFallWarning:
===============
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
116: gotDMIRxPowerHighFallAlarm:
===============
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
118: gotDMIRxPowerLowFallAlarm:
===============
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
120: gotDMIRxPowerHighFallWarning:
===============
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
122: gotDMIRxPowerLowFallWarning:
===============
123: nosRemoteUpgradeRequest:
124: nosRemoteUpgradeSuccess:
125: nosRemoteUpgradeFailAbort:
126: nosRemoteUpgradeFailHeaderError:
127: nosRemoteUpgradeFailDownloadError:
128: nosRemoteUpgradeFailFlashError:
129: nosRemoteUpgradeStart:
===============
130: systemDyingGasp:
===============
133: cliHistory: To detect whether CLI history is detected or not.
134: cliHistoryNo:
===============
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
136: ntpConnectionFailNo:
===============
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
===============
159: clockModuleRemoved: To detect whether clock module is removed or installed.
160: clockModuleInstalled:
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
162: clockModuleInitOk:
===============
163: cliHistoryLog: To detect whether CLI history log is over or not.
164: cliHistoryLogNo:
===============
165: slotActionEvent: To detect whether slot action is changed.
166: slotStateChange: To detect whether slot state is changed.
===============
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
168: interfaceAdminUp:
===============
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
170: slotPowerMonNormal:
===============
171: slotErrorLEDChanged: To detect whether error LED is changed.
===============
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
186: cpuPpsUnderThreshold:
===============
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
200: slotHealthStatusTimeoutCleared:
===============
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
202: advaTemperatureNo:
===============
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
204: advaPSUFailureNo:
===============
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
206: advaFanFailureNo:
===============
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
208: advaInterfaceReceiveFailureNo:
===============
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
less than optical threshold or not.
210: advaInterfaceOpticalThresholdNo:
===============
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
212: advaInterfaceTransmitFaultNo:
===============
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
214: advaInterfaceMisconfigurationNo:
===============
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
216: advaInterfaceSFPMismatchNo:
===============
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
218: advaVoltageLowNo:
===============
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
220: advaVoltageHighNo:
===============
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a node does not receive
any test packet at any of its ports for a period of 3 times.
302: erpDomainLotpNo:
===============
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a RM node of one domain does not
receive any test packet at one port for a period of 3 times.
304: erpDomainULotpNo:
===============
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
The defect is raised when a RM node receives its own test packets
with an Ack destination address field with a non-zero value.
306: erpDomainMultipleRMNo:
===============
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
The detection of multiple failures indicates that the ring is segmented and
that the RM Node is unreacheable.
This is only possible at normal ring nodes isolated from the RM node.
308: erpDomainRMNodeReacheablityNo:
===============
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
===============
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
That is, ONU that its operation is service on should be sent registration information to OLT.
402: eponOnuRegister:
===============
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
404: eponOnuNoRegistrationError:
===============
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
A message between ONU and OLT is encrypted using random encryption key.
There is that the encryption key is invalid as transmission failure from time to time.
406: eponNoBadEncryptionKey:
===============
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
On registering, ONU informs unique ID to OLT.
And then, all communication between ONU and OLT must use the unique ID.
The unique ID is called Llid.
408: eponNoLlidMismatch:
===============
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
410: eponNoTooManyRegister:
===============
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
A ONU could be changed to down state as a number of reasons.
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
then ONU's link would be changed to down.
412: eponNoDyingGASP:
===============
413: eponOnuErrFramePeriod:
414: eponOnuNoErrFramePeriod:
===============
415: eponOnuErrFrame:
416: eponOnuNoErrFrame:
===============
417: eponOnuErrFrameSecondSummary:
418: eponOnuNoErrFrameSecondSummary:
===============
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
420: eponOnuNoLastOnuDeregister:
===============
421: eponOltCableDown:
422: eponOltRecoverCableDown:
===============
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
502: autoCLINoStart:
===============
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
504: autoCLINoComplete:
===============
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
The reason that the result file is removed is that the configured file size for the result is
less than the stored result file size.
If so, the oldest file would be removed before everything.
506: autoCLINoRemoveOutputFile:
===============
507: autoResetSystem: To detect whether the system is restarted or not.
The conditions that system is restarted is that ping loss threshold is
less than current ping loss count during the configured interval and
that current free memory size is less than configured free memory size.
508: autoResetNoSystem:
===============
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
Operator designates any gateway system that can communicate to detect
current network environment.
System sends ICMP packet to the designated gateway system periodically.
If the system doesn't receive ping reply packet within any interval,
operator recognizes that the system can't communicate any more
because of some problems of the system.
510: autoResetNoPingReplyLoss:
===============
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
less than the configured free memory size or not.
Periodically, free memory size is checked to confirm system availability.
512: autoResetNoMemoryLeakDetect:
===============
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
602: arulePacketDropRelease:
===============
620: bME1CardNoDetect:
621: clearBME1CardNoDetect:
===============
622: bME1CardAFEerror:
623: clearBME1CardAFEerror:
===============
624: bME1CardIFEerror:
625: clearBME1CardIFEerror:
===============
626: bME1CardFWerror:
627: clearBME1CardFWerror:
===============
628: bME1CardPROVerror:
629: clearBME1CardPROVerror:
===============
630: bME1CrashDetect:
631: clearBME1CrashDetect:
===============
632: bME2CardNoDetect:
633: clearBME2CardNoDetect:
===============
634: bME2CardAFEerror:
635: clearBME2CardAFEerror:
===============
636: bME2CardIFEerror:
637: clearBME2CardIFEerror:
===============
638: bME2CardFWerror:
639: clearBME2CardFWerror:
===============
640: bME2CardPROVerror:
641: clearBME2CardPROVerror:
===============
642: bME2CrashDetect:
643: clearBME2CrashDetect:
===============
644: bME3CardNoDetect:
645: clearBME3CardNoDetect:
===============
646: bME3CardAFEerror:
647: clearBME3CardAFEerror:
===============
648: bME3CardIFEerror:
649: clearBME3CardIFEerror:
===============
650: bME3CardFWerror:
651: clearBME3CardFWerror:
===============
652: bME3CardPROVerror:
653: clearBME3CardPROVerror:
===============
654: bME3CrashDetect:
655: clearBME3CrashDetect:
===============
656: powerFromBattery:
657: clearPowerFromBattery:
===============
658: invalidBatteryStatus:
659: clearInvalidBatteryStatus:
===============
660: batteryChargeLow:
661: clearBatteryChargeLow:
===============
662: batteryNotPresent:
663: clearBatteryNotPresent:
===============
664: voltageLow:
665: clearVoltageLow:
===============
666: tempOverThreshold:
667: clearTempOverThreshold:
===============
668: tempUnderThreshold:
669: clearTempUnderThreshold:
===============
670: cpuOverThreshold:
671: clearCpuOverThreshold:
===============
672: trafficOverload:
673: clearTrafficOverload:
===============
674: gEPONModuleNotDetect:
675: clearGEPONModuleNotDetect:
===============
676: gEPONPortOperationDown:
677: clearGEPONPortOperationDown:
===============
678: gEPONNoIncomingTraffic:
679: clearGEPONNoIncomingTraffic:
===============
680: processCrashDetect:
681: clearProcessCrashDetect:
===============
682: memoryLeakDetect:
683: clearMemoryLeakDetect:
===============
684: memoryCorrupDetect:
685: clearMemoryCorrupDetect:
===============
686: memoryLowDetect:
687: clearMemoryLowDetect:
===============
688: dataLineerror:
689: clearDataLineerror:
===============
690: addressLineerror:
691: clearAddressLineerror:
===============
692: chipsetNotDetcet:
693: clearChipsetNotDetcet:
===============
694: pciBuserror:
695: clearPciBuserror:
===============
696: securityAdminConnect:
697: clearSecurityAdminConnect:
===============
698: oNUPowerDown:
699: clearONUPowerDown:
===============
700: oNUNotRegister:
701: clearONUNotRegister:
===============
702: oNTOpticPre:
703: clearONTOpticPre:
===============
800: switchoverInitiated:
===============
801: switchoverDone:
===============
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
===============
901: gponNoAuthCBU: To detect no auth CBU is detected.
902: gponDuplicateONU: To detect ONU is duplicated.
903: gponDyingGasp: To detect dying GASP is detected.
904: gponUpgradeComplete: To detect upgrade complete is detected.
905: gponDeregistered: To detect whether deregistered is detected or not.
906: gponRegistered:
907: gponRogueOnu: To detect rogue ONU is detected
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
909: clearGponOnuBetteryEvent:
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
911: gponTransceiverChanged: To detect transceiver is changed.
912: gponOltLosOn: To detect whether OLT LOS is on or off
913: gponOltLosOff:
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
915: gponOltLosiOff:
916: gponDyingGaspOn: To detect whether dying GASP is on or off
917: gponDyingGaspOff:
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
923: gponOnuTemperatureHighFallThreshold:
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
925: gponOnuTemperatureLowFallThreshold:
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
927: gponOnuCpuFallThreshold:
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
929: gponOnuMemoryFallThreshold:
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
932: gponOnuRxOpticLowThreshAlarmOff:
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
934: gponOnuRxOpticHighThreshAlarmOff:
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
936: gponOltLOFIOff:
937: gponOltDOWOn: To detect whether OLT DOW is on or off
938: gponOltDOWOff:
939: gponOltSFOn: To detect whether OLT SF is on or off
940: gponOltSFOff:
941: gponOltSDOn: To detect whether OLT SD is on or off
942: gponOltSDOff:
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
944: gponOltLCDGIOff:
945: gponOltRDOn: To detect whether OLT RD is on or off
946: gponOltRDOff:
947: gponOltSUFOn: To detect whether OLT SUF is on or off
948: gponOltSUFOff:
949: gponOltLOAOn: To detect whether OLT LOA is on or off
950: gponOltLOAOff:
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
952: gponOltLOAMIOff:
953: gponOltMEMOn: To detect whether OLT MEM is on or off
954: gponOltMEMOff:
955: gponOltPEEOn: To detect whether OLT PEE is on or off
956: gponOltPEEOff:
957: gponOltPSTOn: To detect whether OLT PST is on or off
958: gponOltPSTOff:
959: gponOltERROn: To detect whether OLT ERR is on or off
960: gponOltERROff:
961: gponOltREIOn: To detect whether OLT REI is on or off
962: gponOltREIOff:
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
964: gponAntiSpoofingDupPortOff:
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
968: gponOnuPortOpticModuleInstall:
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
970: gponOnuOMCCProblemCleared:
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
972: gponOltFixedTcontAlarmOff:
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
974: gponOltDynamicTcontAlarmOff:
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
976: gponOltPortCountAlarmOff:
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
978: gponOltCableDownAlarmOff:
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
980: gponOltDeactiveMonitorAlarmOff:
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
982: gponOltDfiOff:
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
986: gponOnuPortOperStatusUp::
===============
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
1102: emLogDefectCPUHighUnder:
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
1104: emLogTemperHighUnder:
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
1106: emLogTemperLowOver:
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
1108: emLogMemLowOver:
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
1110: emLogFanFailCleared:
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
1112: emLogPhyCRCFailCleared:
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
1114: emLogPhyDetectFailCleared:
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
1116: emLogSFUMateInitFailCleared:
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
1118: emLogDaemonHealthBadCleared:
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
1120: emLogGPIURavenLinkDownCleared:
===============
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
1152: slotNosUpgradeEnd:
===============
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
1332: gponOnuAniVoltageLowThreshAlarmOff:
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
1334: gponOnuAniVoltageHighThreshAlarmOff:
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
1336: gponOnuAniTemperatureLowThreshAlarmOff:
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
1338: gponOnuAniTemperatureHighThreshAlarmOff:
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
1340: gponOnuAniTxBiasLowThreshAlarmOff:
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
1342: gponOnuAniTxBiasHighThreshAlarmOff:
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
1344: gponOnuAniTxpowerLowThreshAlarmOff:
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
::= { sleAlarmSeverityEntry 1 }
sleAlarmSeverityValue OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleAlarmSeverityEntry 2 }
sleAlarmSeverityControl OBJECT IDENTIFIER ::= { sleAlarmSeverity 2 }
sleAlarmSeverityControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createAlarmSeveriity(1),
destroyAlarmSeveriity(2),
setAlarmSeveriity(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This attribute identifies the control commands.
updateAlarmList:
the NE updates entries of alarms in the sleAlarmListTable
after having changed alarm severities of alarms
(due to change profile pointers in
managed entities or after modification of alarm severities
in profiles). This command should be applied once after having
finisled modifications of severties.
modifyAlarmSeverity:
modifies the severity of an alarm in specific profile.
createAlarmSeverityProfile:
creates a new profile with default severities.
The severities then have to be modified with command changeAlarmSeverity.
deleteAlarmSeverityProfile:
deletes a profile. Profile 1 is not allowed to be deleted.
Notifications : none "
::= { sleAlarmSeverityControl 1 }
sleAlarmSeverityControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleAlarmSeverityControl 2 }
sleAlarmSeverityControlTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleAlarmSeverityControl 3 }
sleAlarmSeverityControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleAlarmSeverityControl 4 }
sleAlarmSeverityControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleAlarmSeverityControl 5 }
sleAlarmSeverityControlIndex OBJECT-TYPE
SYNTAX SpecificNum
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" A number identifying this alarm severity profile.
The following alarms is devided by the specific character, ===============.
The division basis is that alarms is bounded or released.
001: portDown: To detect whether physical or logical interface's link status is up or down.
002: portUp:
===============
003: portRemoved: To detect whether physical interface is installed or not.
004: portInstalled:
===============
005: powerFail: To detect whether power module's operation status is good or not.
(Without doubt, more than 1 power module should be equipped.)
006: powerOK:
===============
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
(Without doubt, more than 1 power module should be equipped.)
008: powerInstalled:
===============
009: fanFail: To detect whether FAN module's operation status is good or not.
010: fanOK:
===============
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
012: fanInstalled:
===============
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
014: moduleInstalled:
===============
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
===============
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
(This alarm isn<73><6E>t used current)
===============
017: broadcastOver: To detect the receipt of broadcast packet.
(This alarm isn<73><6E>t used current)
018: broadcastUnder:
===============
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
020: cpuUnderLoad:
===============
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
022: memoryUnderUsed:
===============
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
less than delta value of current interface's InOctects or not.
024: portUnderThreshold:
===============
025: temperatureHigh: To detect whether the configured system's temperature threshold is
less than current temperature or not.
026: temperatureLow:
===============
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
028: mfgdReleased:
===============
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
030: ipUnconflict:
===============
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
sufficient or not.
032: dhcpLeaseSufficient:
===============
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
034: dhcpRemovedIllegalEntry:
===============
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not. But alarm generation
would be issued by means of event type in RMON event.
036: rmonAlarmNoRising:
===============
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not.
But alarm generation would be issued by means of event type in RMON event.
038: rmonAlarmNoFalling:
===============
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
So STP reconfiguration doesn't use this edge ports.
===============
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So, Root guard prevents a new inserted node from being root bridge as well as
receiving a superior BPDU from root bridge.
but this node participates in STP topology reconfiguration.
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
===============
041: portSecurity: To detect whether interface is configured for security or not.
This can be used to prevent MAC from flooding as well as spoofing.
That is, As a result, this will obstruct an attack as like DoS attack.
===============
042: userLogin:
043: userLogout:
===============
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
052: igmpGroupLeaved:
===============
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
054: dhcpIpaddressFree:
===============
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
056: doorClosed:
===============
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
A system is using AC power usually.
If there is any power problems as like a power failure,
a system is using battery instead of AC power.
058: powerModeChangedBatteryToPower:
===============
059: batterylowcapacity: To detect whether current battery capacity is less
capacity threshold according to battery usage or not.
The capacity of AC power is 16 voltage and battery is 20.
Capacity threshold is configured by H/W specification.
So operator can't change it.
060: batterynormalcapacity:
===============
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
062: batterynormalTemperature:
===============
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
064: authenticationNofail:
===============
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
greater than temperature threshold or not.
066: psuAcNormalTemperature:
===============
067: batteryRemoved: To detect whether battery is equipped at network system or not.
Battery is used as redundancy power service. So operator can decide the installation of battery.
068: batteryEquipped:
===============
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
12.5 volt value is configured by H/W specification. So operator can't change it.
070: batteryNormalVoltage:
===============
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
072: adminAccessLogout:
===============
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
074: cfgdReleased:
===============
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
076: sfgdReleased:
===============
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
078: swWatchdogNormalState:
===============
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
080: swWatchdogClearError:
===============
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
082: ppsControlReleased:
===============
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
084: gotDMITempHighFallAlarm:
===============
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
086: gotDMITempLowFallAlarm:
===============
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
088: gotDMITempHighFallWarning:
===============
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
090: gotDMITempLowFallWarning:
===============
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
092: gotDMIVolHighFallAlarm:
===============
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
094: gotDMIVolLowFallAlarm:
===============
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
096: gotDMIVolHighFallWarning:
===============
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
098: gotDMIVolLowFallWarning:
===============
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
100: gotDMITxBiasHighFallAlarm:
===============
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
102: gotDMITxBiasLowFallAlarm:
===============
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
104: gotDMITxBiasHighFallWarning:
===============
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
106: gotDMITxBiasLowFallWarning:
===============
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
108: gotDMITxPowerHighFallAlarm:
===============
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
110: gotDMITxPowerLowFallAlarm:
===============
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
112: gotDMITxPowerHighFallWarning:
===============
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
114: gotDMITxPowerLowFallWarning:
===============
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
116: gotDMIRxPowerHighFallAlarm:
===============
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
118: gotDMIRxPowerLowFallAlarm:
===============
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
120: gotDMIRxPowerHighFallWarning:
===============
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
122: gotDMIRxPowerLowFallWarning:
===============
123: nosRemoteUpgradeRequest:
124: nosRemoteUpgradeSuccess:
125: nosRemoteUpgradeFailAbort:
126: nosRemoteUpgradeFailHeaderError:
127: nosRemoteUpgradeFailDownloadError:
128: nosRemoteUpgradeFailFlashError:
129: nosRemoteUpgradeStart:
===============
130: systemDyingGasp:
===============
133: cliHistory: To detect whether CLI history is detected or not.
134: cliHistoryNo:
===============
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
136: ntpConnectionFailNo:
===============
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
===============
159: clockModuleRemoved: To detect whether clock module is removed or installed.
160: clockModuleInstalled:
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
162: clockModuleInitOk:
===============
163: cliHistoryLog: To detect whether CLI history log is over or not.
164: cliHistoryLogNo:
===============
165: slotActionEvent: To detect whether slot action is changed.
166: slotStateChange: To detect whether slot state is changed.
===============
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
168: interfaceAdminUp:
===============
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
170: slotPowerMonNormal:
===============
171: slotErrorLEDChanged: To detect whether error LED is changed.
===============
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
186: cpuPpsUnderThreshold:
===============
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
200: slotHealthStatusTimeoutCleared:
===============
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
202: advaTemperatureNo:
===============
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
204: advaPSUFailureNo:
===============
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
206: advaFanFailureNo:
===============
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
208: advaInterfaceReceiveFailureNo:
===============
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
less than optical threshold or not.
210: advaInterfaceOpticalThresholdNo:
===============
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
212: advaInterfaceTransmitFaultNo:
===============
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
214: advaInterfaceMisconfigurationNo:
===============
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
216: advaInterfaceSFPMismatchNo:
===============
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
218: advaVoltageLowNo:
===============
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
220: advaVoltageHighNo:
===============
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a node does not receive
any test packet at any of its ports for a period of 3 times.
302: erpDomainLotpNo:
===============
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a RM node of one domain does not
receive any test packet at one port for a period of 3 times.
304: erpDomainULotpNo:
===============
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
The defect is raised when a RM node receives its own test packets
with an Ack destination address field with a non-zero value.
306: erpDomainMultipleRMNo:
===============
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
The detection of multiple failures indicates that the ring is segmented and
that the RM Node is unreacheable.
This is only possible at normal ring nodes isolated from the RM node.
308: erpDomainRMNodeReacheablityNo:
===============
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
===============
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
That is, ONU that its operation is service on should be sent registration information to OLT.
402: eponOnuRegister:
===============
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
404: eponOnuNoRegistrationError:
===============
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
A message between ONU and OLT is encrypted using random encryption key.
There is that the encryption key is invalid as transmission failure from time to time.
406: eponNoBadEncryptionKey:
===============
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
On registering, ONU informs unique ID to OLT.
And then, all communication between ONU and OLT must use the unique ID.
The unique ID is called Llid.
408: eponNoLlidMismatch:
===============
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
410: eponNoTooManyRegister:
===============
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
A ONU could be changed to down state as a number of reasons.
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
then ONU's link would be changed to down.
412: eponNoDyingGASP:
===============
413: eponOnuErrFramePeriod:
414: eponOnuNoErrFramePeriod:
===============
415: eponOnuErrFrame:
416: eponOnuNoErrFrame:
===============
417: eponOnuErrFrameSecondSummary:
418: eponOnuNoErrFrameSecondSummary:
===============
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
420: eponOnuNoLastOnuDeregister:
===============
421: eponOltCableDown:
422: eponOltRecoverCableDown:
===============
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
502: autoCLINoStart:
===============
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
504: autoCLINoComplete:
===============
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
The reason that the result file is removed is that the configured file size for the result is
less than the stored result file size.
If so, the oldest file would be removed before everything.
506: autoCLINoRemoveOutputFile:
===============
507: autoResetSystem: To detect whether the system is restarted or not.
The conditions that system is restarted is that ping loss threshold is
less than current ping loss count during the configured interval and
that current free memory size is less than configured free memory size.
508: autoResetNoSystem:
===============
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
Operator designates any gateway system that can communicate to detect
current network environment.
System sends ICMP packet to the designated gateway system periodically.
If the system doesn't receive ping reply packet within any interval,
operator recognizes that the system can't communicate any more
because of some problems of the system.
510: autoResetNoPingReplyLoss:
===============
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
less than the configured free memory size or not.
Periodically, free memory size is checked to confirm system availability.
512: autoResetNoMemoryLeakDetect:
===============
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
602: arulePacketDropRelease:
===============
620: bME1CardNoDetect:
621: clearBME1CardNoDetect:
===============
622: bME1CardAFEerror:
623: clearBME1CardAFEerror:
===============
624: bME1CardIFEerror:
625: clearBME1CardIFEerror:
===============
626: bME1CardFWerror:
627: clearBME1CardFWerror:
===============
628: bME1CardPROVerror:
629: clearBME1CardPROVerror:
===============
630: bME1CrashDetect:
631: clearBME1CrashDetect:
===============
632: bME2CardNoDetect:
633: clearBME2CardNoDetect:
===============
634: bME2CardAFEerror:
635: clearBME2CardAFEerror:
===============
636: bME2CardIFEerror:
637: clearBME2CardIFEerror:
===============
638: bME2CardFWerror:
639: clearBME2CardFWerror:
===============
640: bME2CardPROVerror:
641: clearBME2CardPROVerror:
===============
642: bME2CrashDetect:
643: clearBME2CrashDetect:
===============
644: bME3CardNoDetect:
645: clearBME3CardNoDetect:
===============
646: bME3CardAFEerror:
647: clearBME3CardAFEerror:
===============
648: bME3CardIFEerror:
649: clearBME3CardIFEerror:
===============
650: bME3CardFWerror:
651: clearBME3CardFWerror:
===============
652: bME3CardPROVerror:
653: clearBME3CardPROVerror:
===============
654: bME3CrashDetect:
655: clearBME3CrashDetect:
===============
656: powerFromBattery:
657: clearPowerFromBattery:
===============
658: invalidBatteryStatus:
659: clearInvalidBatteryStatus:
===============
660: batteryChargeLow:
661: clearBatteryChargeLow:
===============
662: batteryNotPresent:
663: clearBatteryNotPresent:
===============
664: voltageLow:
665: clearVoltageLow:
===============
666: tempOverThreshold:
667: clearTempOverThreshold:
===============
668: tempUnderThreshold:
669: clearTempUnderThreshold:
===============
670: cpuOverThreshold:
671: clearCpuOverThreshold:
===============
672: trafficOverload:
673: clearTrafficOverload:
===============
674: gEPONModuleNotDetect:
675: clearGEPONModuleNotDetect:
===============
676: gEPONPortOperationDown:
677: clearGEPONPortOperationDown:
===============
678: gEPONNoIncomingTraffic:
679: clearGEPONNoIncomingTraffic:
===============
680: processCrashDetect:
681: clearProcessCrashDetect:
===============
682: memoryLeakDetect:
683: clearMemoryLeakDetect:
===============
684: memoryCorrupDetect:
685: clearMemoryCorrupDetect:
===============
686: memoryLowDetect:
687: clearMemoryLowDetect:
===============
688: dataLineerror:
689: clearDataLineerror:
===============
690: addressLineerror:
691: clearAddressLineerror:
===============
692: chipsetNotDetcet:
693: clearChipsetNotDetcet:
===============
694: pciBuserror:
695: clearPciBuserror:
===============
696: securityAdminConnect:
697: clearSecurityAdminConnect:
===============
698: oNUPowerDown:
699: clearONUPowerDown:
===============
700: oNUNotRegister:
701: clearONUNotRegister:
===============
702: oNTOpticPre:
703: clearONTOpticPre:
===============
800: switchoverInitiated:
===============
801: switchoverDone:
===============
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
===============
901: gponNoAuthCBU: To detect no auth CBU is detected.
902: gponDuplicateONU: To detect ONU is duplicated.
903: gponDyingGasp: To detect dying GASP is detected.
904: gponUpgradeComplete: To detect upgrade complete is detected.
905: gponDeregistered: To detect whether deregistered is detected or not.
906: gponRegistered:
907: gponRogueOnu: To detect rogue ONU is detected
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
909: clearGponOnuBetteryEvent:
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
911: gponTransceiverChanged: To detect transceiver is changed.
912: gponOltLosOn: To detect whether OLT LOS is on or off
913: gponOltLosOff:
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
915: gponOltLosiOff:
916: gponDyingGaspOn: To detect whether dying GASP is on or off
917: gponDyingGaspOff:
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
923: gponOnuTemperatureHighFallThreshold:
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
925: gponOnuTemperatureLowFallThreshold:
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
927: gponOnuCpuFallThreshold:
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
929: gponOnuMemoryFallThreshold:
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
932: gponOnuRxOpticLowThreshAlarmOff:
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
934: gponOnuRxOpticHighThreshAlarmOff:
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
936: gponOltLOFIOff:
937: gponOltDOWOn: To detect whether OLT DOW is on or off
938: gponOltDOWOff:
939: gponOltSFOn: To detect whether OLT SF is on or off
940: gponOltSFOff:
941: gponOltSDOn: To detect whether OLT SD is on or off
942: gponOltSDOff:
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
944: gponOltLCDGIOff:
945: gponOltRDOn: To detect whether OLT RD is on or off
946: gponOltRDOff:
947: gponOltSUFOn: To detect whether OLT SUF is on or off
948: gponOltSUFOff:
949: gponOltLOAOn: To detect whether OLT LOA is on or off
950: gponOltLOAOff:
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
952: gponOltLOAMIOff:
953: gponOltMEMOn: To detect whether OLT MEM is on or off
954: gponOltMEMOff:
955: gponOltPEEOn: To detect whether OLT PEE is on or off
956: gponOltPEEOff:
957: gponOltPSTOn: To detect whether OLT PST is on or off
958: gponOltPSTOff:
959: gponOltERROn: To detect whether OLT ERR is on or off
960: gponOltERROff:
961: gponOltREIOn: To detect whether OLT REI is on or off
962: gponOltREIOff:
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
964: gponAntiSpoofingDupPortOff:
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
968: gponOnuPortOpticModuleInstall:
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
970: gponOnuOMCCProblemCleared:
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
972: gponOltFixedTcontAlarmOff:
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
974: gponOltDynamicTcontAlarmOff:
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
976: gponOltPortCountAlarmOff:
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
978: gponOltCableDownAlarmOff:
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
980: gponOltDeactiveMonitorAlarmOff:
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
982: gponOltDfiOff:
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
986: gponOnuPortOperStatusUp::
===============
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
1102: emLogDefectCPUHighUnder:
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
1104: emLogTemperHighUnder:
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
1106: emLogTemperLowOver:
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
1108: emLogMemLowOver:
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
1110: emLogFanFailCleared:
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
1112: emLogPhyCRCFailCleared:
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
1114: emLogPhyDetectFailCleared:
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
1116: emLogSFUMateInitFailCleared:
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
1118: emLogDaemonHealthBadCleared:
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
1120: emLogGPIURavenLinkDownCleared:
===============
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
1152: slotNosUpgradeEnd:
===============
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
1332: gponOnuAniVoltageLowThreshAlarmOff:
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
1334: gponOnuAniVoltageHighThreshAlarmOff:
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
1336: gponOnuAniTemperatureLowThreshAlarmOff:
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
1338: gponOnuAniTemperatureHighThreshAlarmOff:
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
1340: gponOnuAniTxBiasLowThreshAlarmOff:
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
1342: gponOnuAniTxBiasHighThreshAlarmOff:
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
1344: gponOnuAniTxpowerLowThreshAlarmOff:
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
::= { sleAlarmSeverityControl 6 }
sleAlarmSeverityControlValue OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleAlarmSeverityControl 7 }
sleAlarmSeverityNotification OBJECT IDENTIFIER ::= { sleAlarmSeverity 3 }
sleAlarmSeveriityCreated NOTIFICATION-TYPE
OBJECTS { sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmSeverityNotification 1 }
sleAlarmSeveriityDestroyed NOTIFICATION-TYPE
OBJECTS { sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult, sleAlarmSeverityValue }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmSeverityNotification 2 }
sleAlarmSeverityChanged NOTIFICATION-TYPE
OBJECTS { sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmSeverityNotification 3 }
sleAlarmReport OBJECT IDENTIFIER ::= { sleFaultMgmt 3 }
sleAlarmReportTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAlarmReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The alarm list table is used to store all reported alarms. "
::= { sleAlarmReport 1 }
sleAlarmReportEntry OBJECT-TYPE
SYNTAX SleAlarmReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Entry of the alarm lis table. "
INDEX { sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource }
::= { sleAlarmReportTable 1 }
SleAlarmReportEntry ::=
SEQUENCE {
sleAlarmSpecificCode
SpecificNum,
sleAlarmReportingSourceType
INTEGER,
sleAlarmReportingSource
OCTET STRING,
sleAlarmSpecificSeverity
INTEGER,
sleAlarmSpecificProblem
Unsigned32,
sleAlarmSpecificProblemText
OCTET STRING,
sleAlarmTimeAndDate
Integer32,
sleAlarmSpecificSeqNum
Counter32,
sleAlarmReportPairType
INTEGER
}
sleAlarmSpecificCode OBJECT-TYPE
SYNTAX SpecificNum
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The OID of alarm.
The following alarms is devided by the specific character, ===============.
The division basis is that alarms is bounded or released.
001: portDown: To detect whether physical or logical interface's link status is up or down.
002: portUp:
===============
003: portRemoved: To detect whether physical interface is installed or not.
004: portInstalled:
===============
005: powerFail: To detect whether power module's operation status is good or not.
(Without doubt, more than 1 power module should be equipped.)
006: powerOK:
===============
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
(Without doubt, more than 1 power module should be equipped.)
008: powerInstalled:
===============
009: fanFail: To detect whether FAN module's operation status is good or not.
010: fanOK:
===============
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
012: fanInstalled:
===============
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
014: moduleInstalled:
===============
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
===============
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
(This alarm isn<73><6E>t used current)
===============
017: broadcastOver: To detect the receipt of broadcast packet.
(This alarm isn<73><6E>t used current)
018: broadcastUnder:
===============
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
020: cpuUnderLoad:
===============
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
022: memoryUnderUsed:
===============
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
less than delta value of current interface's InOctects or not.
024: portUnderThreshold:
===============
025: temperatureHigh: To detect whether the configured system's temperature threshold is
less than current temperature or not.
026: temperatureLow:
===============
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
028: mfgdReleased:
===============
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
030: ipUnconflict:
===============
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
sufficient or not.
032: dhcpLeaseSufficient:
===============
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
034: dhcpRemovedIllegalEntry:
===============
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not. But alarm generation
would be issued by means of event type in RMON event.
036: rmonAlarmNoRising:
===============
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not.
But alarm generation would be issued by means of event type in RMON event.
038: rmonAlarmNoFalling:
===============
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
So STP reconfiguration doesn't use this edge ports.
===============
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So, Root guard prevents a new inserted node from being root bridge as well as
receiving a superior BPDU from root bridge.
but this node participates in STP topology reconfiguration.
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
===============
041: portSecurity: To detect whether interface is configured for security or not.
This can be used to prevent MAC from flooding as well as spoofing.
That is, As a result, this will obstruct an attack as like DoS attack.
===============
042: userLogin:
043: userLogout:
===============
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
052: igmpGroupLeaved:
===============
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
054: dhcpIpaddressFree:
===============
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
056: doorClosed:
===============
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
A system is using AC power usually.
If there is any power problems as like a power failure,
a system is using battery instead of AC power.
058: powerModeChangedBatteryToPower:
===============
059: batterylowcapacity: To detect whether current battery capacity is less
capacity threshold according to battery usage or not.
The capacity of AC power is 16 voltage and battery is 20.
Capacity threshold is configured by H/W specification.
So operator can't change it.
060: batterynormalcapacity:
===============
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
062: batterynormalTemperature:
===============
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
064: authenticationNofail:
===============
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
greater than temperature threshold or not.
066: psuAcNormalTemperature:
===============
067: batteryRemoved: To detect whether battery is equipped at network system or not.
Battery is used as redundancy power service. So operator can decide the installation of battery.
068: batteryEquipped:
===============
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
12.5 volt value is configured by H/W specification. So operator can't change it.
070: batteryNormalVoltage:
===============
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
072: adminAccessLogout:
===============
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
074: cfgdReleased:
===============
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
076: sfgdReleased:
===============
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
078: swWatchdogNormalState:
===============
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
080: swWatchdogClearError:
===============
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
082: ppsControlReleased:
===============
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
084: gotDMITempHighFallAlarm:
===============
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
086: gotDMITempLowFallAlarm:
===============
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
088: gotDMITempHighFallWarning:
===============
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
090: gotDMITempLowFallWarning:
===============
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
092: gotDMIVolHighFallAlarm:
===============
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
094: gotDMIVolLowFallAlarm:
===============
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
096: gotDMIVolHighFallWarning:
===============
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
098: gotDMIVolLowFallWarning:
===============
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
100: gotDMITxBiasHighFallAlarm:
===============
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
102: gotDMITxBiasLowFallAlarm:
===============
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
104: gotDMITxBiasHighFallWarning:
===============
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
106: gotDMITxBiasLowFallWarning:
===============
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
108: gotDMITxPowerHighFallAlarm:
===============
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
110: gotDMITxPowerLowFallAlarm:
===============
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
112: gotDMITxPowerHighFallWarning:
===============
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
114: gotDMITxPowerLowFallWarning:
===============
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
116: gotDMIRxPowerHighFallAlarm:
===============
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
118: gotDMIRxPowerLowFallAlarm:
===============
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
120: gotDMIRxPowerHighFallWarning:
===============
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
122: gotDMIRxPowerLowFallWarning:
===============
123: nosRemoteUpgradeRequest:
124: nosRemoteUpgradeSuccess:
125: nosRemoteUpgradeFailAbort:
126: nosRemoteUpgradeFailHeaderError:
127: nosRemoteUpgradeFailDownloadError:
128: nosRemoteUpgradeFailFlashError:
129: nosRemoteUpgradeStart:
===============
130: systemDyingGasp:
===============
133: cliHistory: To detect whether CLI history is detected or not.
134: cliHistoryNo:
===============
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
136: ntpConnectionFailNo:
===============
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
===============
159: clockModuleRemoved: To detect whether clock module is removed or installed.
160: clockModuleInstalled:
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
162: clockModuleInitOk:
===============
163: cliHistoryLog: To detect whether CLI history log is over or not.
164: cliHistoryLogNo:
===============
165: slotActionEvent: To detect whether slot action is changed.
166: slotStateChange: To detect whether slot state is changed.
===============
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
168: interfaceAdminUp:
===============
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
170: slotPowerMonNormal:
===============
171: slotErrorLEDChanged: To detect whether error LED is changed.
===============
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
186: cpuPpsUnderThreshold:
===============
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
200: slotHealthStatusTimeoutCleared:
===============
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
202: advaTemperatureNo:
===============
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
204: advaPSUFailureNo:
===============
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
206: advaFanFailureNo:
===============
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
208: advaInterfaceReceiveFailureNo:
===============
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
less than optical threshold or not.
210: advaInterfaceOpticalThresholdNo:
===============
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
212: advaInterfaceTransmitFaultNo:
===============
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
214: advaInterfaceMisconfigurationNo:
===============
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
216: advaInterfaceSFPMismatchNo:
===============
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
218: advaVoltageLowNo:
===============
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
220: advaVoltageHighNo:
===============
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a node does not receive
any test packet at any of its ports for a period of 3 times.
302: erpDomainLotpNo:
===============
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a RM node of one domain does not
receive any test packet at one port for a period of 3 times.
304: erpDomainULotpNo:
===============
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
The defect is raised when a RM node receives its own test packets
with an Ack destination address field with a non-zero value.
306: erpDomainMultipleRMNo:
===============
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
The detection of multiple failures indicates that the ring is segmented and
that the RM Node is unreacheable.
This is only possible at normal ring nodes isolated from the RM node.
308: erpDomainRMNodeReacheablityNo:
===============
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
===============
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
That is, ONU that its operation is service on should be sent registration information to OLT.
402: eponOnuRegister:
===============
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
404: eponOnuNoRegistrationError:
===============
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
A message between ONU and OLT is encrypted using random encryption key.
There is that the encryption key is invalid as transmission failure from time to time.
406: eponNoBadEncryptionKey:
===============
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
On registering, ONU informs unique ID to OLT.
And then, all communication between ONU and OLT must use the unique ID.
The unique ID is called Llid.
408: eponNoLlidMismatch:
===============
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
410: eponNoTooManyRegister:
===============
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
A ONU could be changed to down state as a number of reasons.
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
then ONU's link would be changed to down.
412: eponNoDyingGASP:
===============
413: eponOnuErrFramePeriod:
414: eponOnuNoErrFramePeriod:
===============
415: eponOnuErrFrame:
416: eponOnuNoErrFrame:
===============
417: eponOnuErrFrameSecondSummary:
418: eponOnuNoErrFrameSecondSummary:
===============
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
420: eponOnuNoLastOnuDeregister:
===============
421: eponOltCableDown:
422: eponOltRecoverCableDown:
===============
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
502: autoCLINoStart:
===============
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
504: autoCLINoComplete:
===============
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
The reason that the result file is removed is that the configured file size for the result is
less than the stored result file size.
If so, the oldest file would be removed before everything.
506: autoCLINoRemoveOutputFile:
===============
507: autoResetSystem: To detect whether the system is restarted or not.
The conditions that system is restarted is that ping loss threshold is
less than current ping loss count during the configured interval and
that current free memory size is less than configured free memory size.
508: autoResetNoSystem:
===============
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
Operator designates any gateway system that can communicate to detect
current network environment.
System sends ICMP packet to the designated gateway system periodically.
If the system doesn't receive ping reply packet within any interval,
operator recognizes that the system can't communicate any more
because of some problems of the system.
510: autoResetNoPingReplyLoss:
===============
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
less than the configured free memory size or not.
Periodically, free memory size is checked to confirm system availability.
512: autoResetNoMemoryLeakDetect:
===============
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
602: arulePacketDropRelease:
===============
620: bME1CardNoDetect:
621: clearBME1CardNoDetect:
===============
622: bME1CardAFEerror:
623: clearBME1CardAFEerror:
===============
624: bME1CardIFEerror:
625: clearBME1CardIFEerror:
===============
626: bME1CardFWerror:
627: clearBME1CardFWerror:
===============
628: bME1CardPROVerror:
629: clearBME1CardPROVerror:
===============
630: bME1CrashDetect:
631: clearBME1CrashDetect:
===============
632: bME2CardNoDetect:
633: clearBME2CardNoDetect:
===============
634: bME2CardAFEerror:
635: clearBME2CardAFEerror:
===============
636: bME2CardIFEerror:
637: clearBME2CardIFEerror:
===============
638: bME2CardFWerror:
639: clearBME2CardFWerror:
===============
640: bME2CardPROVerror:
641: clearBME2CardPROVerror:
===============
642: bME2CrashDetect:
643: clearBME2CrashDetect:
===============
644: bME3CardNoDetect:
645: clearBME3CardNoDetect:
===============
646: bME3CardAFEerror:
647: clearBME3CardAFEerror:
===============
648: bME3CardIFEerror:
649: clearBME3CardIFEerror:
===============
650: bME3CardFWerror:
651: clearBME3CardFWerror:
===============
652: bME3CardPROVerror:
653: clearBME3CardPROVerror:
===============
654: bME3CrashDetect:
655: clearBME3CrashDetect:
===============
656: powerFromBattery:
657: clearPowerFromBattery:
===============
658: invalidBatteryStatus:
659: clearInvalidBatteryStatus:
===============
660: batteryChargeLow:
661: clearBatteryChargeLow:
===============
662: batteryNotPresent:
663: clearBatteryNotPresent:
===============
664: voltageLow:
665: clearVoltageLow:
===============
666: tempOverThreshold:
667: clearTempOverThreshold:
===============
668: tempUnderThreshold:
669: clearTempUnderThreshold:
===============
670: cpuOverThreshold:
671: clearCpuOverThreshold:
===============
672: trafficOverload:
673: clearTrafficOverload:
===============
674: gEPONModuleNotDetect:
675: clearGEPONModuleNotDetect:
===============
676: gEPONPortOperationDown:
677: clearGEPONPortOperationDown:
===============
678: gEPONNoIncomingTraffic:
679: clearGEPONNoIncomingTraffic:
===============
680: processCrashDetect:
681: clearProcessCrashDetect:
===============
682: memoryLeakDetect:
683: clearMemoryLeakDetect:
===============
684: memoryCorrupDetect:
685: clearMemoryCorrupDetect:
===============
686: memoryLowDetect:
687: clearMemoryLowDetect:
===============
688: dataLineerror:
689: clearDataLineerror:
===============
690: addressLineerror:
691: clearAddressLineerror:
===============
692: chipsetNotDetcet:
693: clearChipsetNotDetcet:
===============
694: pciBuserror:
695: clearPciBuserror:
===============
696: securityAdminConnect:
697: clearSecurityAdminConnect:
===============
698: oNUPowerDown:
699: clearONUPowerDown:
===============
700: oNUNotRegister:
701: clearONUNotRegister:
===============
702: oNTOpticPre:
703: clearONTOpticPre:
===============
800: switchoverInitiated:
===============
801: switchoverDone:
===============
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
===============
901: gponNoAuthCBU: To detect no auth CBU is detected.
902: gponDuplicateONU: To detect ONU is duplicated.
903: gponDyingGasp: To detect dying GASP is detected.
904: gponUpgradeComplete: To detect upgrade complete is detected.
905: gponDeregistered: To detect whether deregistered is detected or not.
906: gponRegistered:
907: gponRogueOnu: To detect rogue ONU is detected
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
909: clearGponOnuBetteryEvent:
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
911: gponTransceiverChanged: To detect transceiver is changed.
912: gponOltLosOn: To detect whether OLT LOS is on or off
913: gponOltLosOff:
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
915: gponOltLosiOff:
916: gponDyingGaspOn: To detect whether dying GASP is on or off
917: gponDyingGaspOff:
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
923: gponOnuTemperatureHighFallThreshold:
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
925: gponOnuTemperatureLowFallThreshold:
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
927: gponOnuCpuFallThreshold:
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
929: gponOnuMemoryFallThreshold:
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
932: gponOnuRxOpticLowThreshAlarmOff:
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
934: gponOnuRxOpticHighThreshAlarmOff:
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
936: gponOltLOFIOff:
937: gponOltDOWOn: To detect whether OLT DOW is on or off
938: gponOltDOWOff:
939: gponOltSFOn: To detect whether OLT SF is on or off
940: gponOltSFOff:
941: gponOltSDOn: To detect whether OLT SD is on or off
942: gponOltSDOff:
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
944: gponOltLCDGIOff:
945: gponOltRDOn: To detect whether OLT RD is on or off
946: gponOltRDOff:
947: gponOltSUFOn: To detect whether OLT SUF is on or off
948: gponOltSUFOff:
949: gponOltLOAOn: To detect whether OLT LOA is on or off
950: gponOltLOAOff:
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
952: gponOltLOAMIOff:
953: gponOltMEMOn: To detect whether OLT MEM is on or off
954: gponOltMEMOff:
955: gponOltPEEOn: To detect whether OLT PEE is on or off
956: gponOltPEEOff:
957: gponOltPSTOn: To detect whether OLT PST is on or off
958: gponOltPSTOff:
959: gponOltERROn: To detect whether OLT ERR is on or off
960: gponOltERROff:
961: gponOltREIOn: To detect whether OLT REI is on or off
962: gponOltREIOff:
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
964: gponAntiSpoofingDupPortOff:
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
968: gponOnuPortOpticModuleInstall:
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
970: gponOnuOMCCProblemCleared:
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
972: gponOltFixedTcontAlarmOff:
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
974: gponOltDynamicTcontAlarmOff:
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
976: gponOltPortCountAlarmOff:
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
978: gponOltCableDownAlarmOff:
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
980: gponOltDeactiveMonitorAlarmOff:
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
982: gponOltDfiOff:
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
986: gponOnuPortOperStatusUp::
===============
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
1102: emLogDefectCPUHighUnder:
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
1104: emLogTemperHighUnder:
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
1106: emLogTemperLowOver:
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
1108: emLogMemLowOver:
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
1110: emLogFanFailCleared:
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
1112: emLogPhyCRCFailCleared:
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
1114: emLogPhyDetectFailCleared:
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
1116: emLogSFUMateInitFailCleared:
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
1118: emLogDaemonHealthBadCleared:
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
1120: emLogGPIURavenLinkDownCleared:
===============
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
1152: slotNosUpgradeEnd:
===============
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
1332: gponOnuAniVoltageLowThreshAlarmOff:
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
1334: gponOnuAniVoltageHighThreshAlarmOff:
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
1336: gponOnuAniTemperatureLowThreshAlarmOff:
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
1338: gponOnuAniTemperatureHighThreshAlarmOff:
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
1340: gponOnuAniTxBiasLowThreshAlarmOff:
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
1342: gponOnuAniTxBiasHighThreshAlarmOff:
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
1344: gponOnuAniTxpowerLowThreshAlarmOff:
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
::= { sleAlarmReportEntry 1 }
sleAlarmReportingSourceType OBJECT-TYPE
SYNTAX INTEGER
{
entPhysicalEntity(1),
ifIndex(2),
vccTp(3),
macAddress(4),
ipv4(5),
ipv6(6),
threshold(7),
advaSource(8),
number(9),
general(10),
eponSource(11),
gponSource(12),
gponSourceTlv(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Reporting source
In case of source type 13 gponSourceTlv,
It's shown as below.
sleAlarmReportingSourceType.A.B.C.D.E.F
A: sleAlarmSpecificCode
B: sleAlarmReportingSourceType 13
C: sleAlarmReportingSource's length
D: type 1-slot 2-port 3-vlan 4-MAC 5-ONU 6-UNI_type 7-UNI_index 255-etc
E: legth
F: value
"
::= { sleAlarmReportEntry 2 }
sleAlarmReportingSource OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The alarm severity of alarm.
In case of source type 13 gponSourceTlv,
It's shown as below.
sleAlarmReportingSourceType.A.B.C.D.E.F
A: sleAlarmSpecificCode
B: sleAlarmReportingSourceType 13
C: sleAlarmReportingSource's length
D: type 1-slot 2-port 3-vlan 4-MAC 5-ONU 6-UNI_type 7-UNI_index 255-etc
E: legth
F: value"
::= { sleAlarmReportEntry 3 }
sleAlarmSpecificSeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5),
cleared(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm severity. The value cleared indicates the clearing of alarm."
::= { sleAlarmReportEntry 4 }
sleAlarmSpecificProblem OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the spefic problems e.g. when a shePhysCardFailure is sent here the termperature alarm is specified"
::= { sleAlarmReportEntry 5 }
sleAlarmSpecificProblemText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of specific problem reported by alarming.
To be discussed: Option is to define an alarm for every problem
"
::= { sleAlarmReportEntry 6 }
sleAlarmTimeAndDate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the alarm appeared or cleared"
::= { sleAlarmReportEntry 7 }
sleAlarmSpecificSeqNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sequence number for the alarm synchronization.
This value has a number to be used for the next alarm trap."
::= { sleAlarmReportEntry 8 }
sleAlarmReportPairType OBJECT-TYPE
SYNTAX INTEGER
{
pair(0),
mono(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type is whether alarm trap is pair or mono."
::= { sleAlarmReportEntry 9 }
sleAlarmReportNotification OBJECT IDENTIFIER ::= { sleAlarmReport 2 }
sleAlarmReportNotified NOTIFICATION-TYPE
OBJECTS { sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource, sleAlarmTimeAndDate, sleAlarmSpecificSeverity,
sleAlarmSpecificProblem, sleAlarmSpecificProblemText, sleAlarmSpecificSeqNum }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportNotification 1 }
sleAlarmReportControl OBJECT IDENTIFIER ::= { sleAlarmReport 3 }
sleAlarmReportControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
clearAlarmReport(1),
delAlarmReport(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportControl 1 }
sleAlarmReportControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportControl 2 }
sleAlarmReportControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportControl 3 }
sleAlarmReportControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportControl 4 }
sleAlarmReportControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportControl 5 }
sleAlarmReportControlSpecificCode OBJECT-TYPE
SYNTAX SpecificNum
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm specific code"
::= { sleAlarmReportControl 6 }
sleAlarmReportControlSourceType OBJECT-TYPE
SYNTAX INTEGER
{
entPhysicalEntity(1),
ifIndex(2),
vccTp(3),
macAddress(4),
ipv4(5),
ipv6(6),
threshold(7),
advaSource(8),
number(9),
general(10),
eponSource(11),
gponSource(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of Reporting source"
::= { sleAlarmReportControl 7 }
sleAlarmReportControlSource OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The index of the failed component which reports the alarm.
It is the entPhysicalIndex in case of a card is reporting, or the ifIndex in case of an interface reporting"
::= { sleAlarmReportControl 8 }
sleAlarmReportNotifications OBJECT IDENTIFIER ::= { sleAlarmReport 4 }
sleAlarmReportCleared NOTIFICATION-TYPE
OBJECTS { sleAlarmReportControlRequest, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportNotifications 1 }
sleAlarmReportDeleted NOTIFICATION-TYPE
OBJECTS { sleAlarmReportControlRequest, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult, sleAlarmReportControlSpecificCode, sleAlarmReportControlSourceType,
sleAlarmReportControlSource }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmReportNotifications 2 }
sleAlarmHistory OBJECT IDENTIFIER ::= { sleFaultMgmt 4 }
sleAlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAlarmHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The alarm severity table.
The alarm severity table associates
profile index and AlarmID pairs with severities to be
used for alarm traps.
(Note that this table does not apply to cleared alarms). "
::= { sleAlarmHistory 1 }
sleAlarmHistoryEntry OBJECT-TYPE
SYNTAX SleAlarmHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Entry of the alarm severity table. "
INDEX { sleAlarmHistoryIndex }
::= { sleAlarmHistoryTable 1 }
SleAlarmHistoryEntry ::=
SEQUENCE {
sleAlarmHistoryIndex
INTEGER,
sleAlarmHistorySpecific
SpecificNum,
sleAlarmHistorySeverity
INTEGER,
sleAlarmHistoryText
OCTET STRING,
sleAlarmHistoryTime
Integer32,
sleAlarmHistorySeqNum
Counter32,
sleAlarmHistoryPairType
INTEGER
}
sleAlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The OID of alarm. "
::= { sleAlarmHistoryEntry 1 }
sleAlarmHistorySpecific OBJECT-TYPE
SYNTAX SpecificNum
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The OID of alarm.
The following alarms is devided by the specific character, ===============.
The division basis is that alarms is bounded or released.
001: portDown: To detect whether physical or logical interface's link status is up or down.
002: portUp:
===============
003: portRemoved: To detect whether physical interface is installed or not.
004: portInstalled:
===============
005: powerFail: To detect whether power module's operation status is good or not.
(Without doubt, more than 1 power module should be equipped.)
006: powerOK:
===============
007: powerRemoved: To detect whether power module is installed or not, through the PLD access.
(Without doubt, more than 1 power module should be equipped.)
008: powerInstalled:
===============
009: fanFail: To detect whether FAN module's operation status is good or not.
010: fanOK:
===============
011: fanRemoved: To detect whether FAN module is installed or not, through the PLD access.
012: fanInstalled:
===============
013: moduleRemoved: To detect whether physical interface module is installed or not, through the S/W I2C
014: moduleInstalled:
===============
015: systemRestart: Network system is restarted by operator. This is not H/W start but S/W start.
===============
016: systemStart: Network system is restarted by operator or system status. This is not S/W start but H/W start.
(This alarm isn<73><6E>t used current)
===============
017: broadcastOver: To detect the receipt of broadcast packet.
(This alarm isn<73><6E>t used current)
018: broadcastUnder:
===============
019: cpuOverLoad: To detect whether the configured CPU load threshold is less than current CPU load usage or not.
020: cpuUnderLoad:
===============
021: memoryOverUsed: To detect whether the configured memory threshold is less than current memory usage or not.
022: memoryUnderUsed:
===============
023: portOverThreshold: To detect whether the configured physical or logical interface threshold is
less than delta value of current interface's InOctects or not.
024: portUnderThreshold:
===============
025: temperatureHigh: To detect whether the configured system's temperature threshold is
less than current temperature or not.
026: temperatureLow:
===============
027: mfgdBlocked: To detect whether the specific MAC by MAC flood guard is blocked or not.
028: mfgdReleased:
===============
029: ipConflict: To detect whether the same IP address on different network node is configured or not.
030: ipUnconflict:
===============
031: dhcpLeaseShortage: To detect whether IP address that can be assigned to subscriber by DHCP server is
sufficient or not.
032: dhcpLeaseSufficient:
===============
033: dhcpOccuredIllegalEntry: To detect whether a subsceiber is using a static IP address or not.
034: dhcpRemovedIllegalEntry:
===============
035: rmonAlarmRising: To detect whether rising threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not. But alarm generation
would be issued by means of event type in RMON event.
036: rmonAlarmNoRising:
===============
037: rmonAlarmFalling: To detect whether falling threshold of a specific MO in RMON alarm sampling is
less than current calculated value by alarm sample type or not.
But alarm generation would be issued by means of event type in RMON event.
038: rmonAlarmNoFalling:
===============
039: bpduGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So these edge ports is guarded, and then edge ports is blocked about all superior BPDU.
So STP reconfiguration doesn't use this edge ports.
===============
040: rootGuardDisabled: To detect whether edge ports is guarded about superior BPDU or not.
In case of insertion edge node with 0 or lower priority than priority of current root bridge node,
it will be disarrangement during a short time because of recognition a new inserted node
as root bridge.
So, Root guard prevents a new inserted node from being root bridge as well as
receiving a superior BPDU from root bridge.
but this node participates in STP topology reconfiguration.
If root bridge does not send a superior BPDU, then this node acts usually though STP state change.
===============
041: portSecurity: To detect whether interface is configured for security or not.
This can be used to prevent MAC from flooding as well as spoofing.
That is, As a result, this will obstruct an attack as like DoS attack.
===============
042: userLogin:
043: userLogout:
===============
051: igmpGroupJoined: To detect whether a subscriber is joined a multicast group or not.
052: igmpGroupLeaved:
===============
053: dhcpIpaddressBound: To detect wether a dynamic IP address is assigned to a subscriber or not.
054: dhcpIpaddressFree:
===============
055: doorOpened: To detect whether outer door is opeded or not, as external alarm.
056: doorClosed:
===============
057: powerModeChangedPowerToBattery: To detect whether a system is using AC power or battery.
A system is using AC power usually.
If there is any power problems as like a power failure,
a system is using battery instead of AC power.
058: powerModeChangedBatteryToPower:
===============
059: batterylowcapacity: To detect whether current battery capacity is less
capacity threshold according to battery usage or not.
The capacity of AC power is 16 voltage and battery is 20.
Capacity threshold is configured by H/W specification.
So operator can't change it.
060: batterynormalcapacity:
===============
061: batteryhighTemperature: To detect whether current temperature of battery is greater than temperature threshold or not.
062: batterynormalTemperature:
===============
063: authenticationFail: To detect whether the connected user is authentic or non-authentic.
064: authenticationNofail:
===============
065: psuAcHighTemperature: To detect whether current temperature of Power Supply Unit is
greater than temperature threshold or not.
066: psuAcNormalTemperature:
===============
067: batteryRemoved: To detect whether battery is equipped at network system or not.
Battery is used as redundancy power service. So operator can decide the installation of battery.
068: batteryEquipped:
===============
069: batteryLowVoltage: To detect whether battery voltage is less than 12.5 volt or not.
12.5 volt value is configured by H/W specification. So operator can't change it.
070: batteryNormalVoltage:
===============
071: adminAccessLogin: To detect whether a operator connects at this network system or not.
072: adminAccessLogout:
===============
073: cfgdBlocked: To detect whether it is blocked flood to CPU or not.
074: cfgdReleased:
===============
075: sfgdBlocked: To detect whether it is blocked flood to system or not.
076: sfgdReleased:
===============
077: swWatchdogAbnormalState: To detect whether a specific process acts normally or not.
078: swWatchdogNormalState:
===============
079: swWatchdogDetectError: To detect whether a specific process is detected a error related to itself or cleared.
080: swWatchdogClearError:
===============
081: ppsControlBlocked: To detect whether it is blocked by pps-control or not.
082: ppsControlReleased:
===============
083: gotDMITempHighOverAlarm: To detect whether internal temperature exceeds high alarm level or not.
084: gotDMITempHighFallAlarm:
===============
085: gotDMITempLowOverAlarm: To detect whether internal temperature is below low alarm level or not.
086: gotDMITempLowFallAlarm:
===============
087: gotDMITempHighOverWarning: To detect whether internal temperature exceeds high warning level or not.
088: gotDMITempHighFallWarning:
===============
089: gotDMITempLowOverWarning: To detect whether internal temperature is below low warning level or not.
090: gotDMITempLowFallWarning:
===============
091: gotDMIVolHighOverAlarm: To detect whether internal supply voltage exceeds high alarm level or not.
092: gotDMIVolHighFallAlarm:
===============
093: gotDMIVolLowOverAlarm: To detect whether internal supply voltage is below low alarm level or not.
094: gotDMIVolLowFallAlarm:
===============
095: gotDMIVolHighOverWarning: To detect whether internal supply voltage exceeds high warning level or not.
096: gotDMIVolHighFallWarning:
===============
097: gotDMIVolLowOverWarning: To detect whether internal supply voltage is below low warning level or not.
098: gotDMIVolLowFallWarning:
===============
099: gotDMITxBiasHighOverAlarm: To detect whether TX Bias current exceeds high alarm level or not.
100: gotDMITxBiasHighFallAlarm:
===============
101: gotDMITxBiasLowOverAlarm: To detect whether TX Bias current is below low alarm level or not.
102: gotDMITxBiasLowFallAlarm:
===============
103: gotDMITxBiasHighOverWarning: To detect whether TX Bias current exceeds high warning level or not.
104: gotDMITxBiasHighFallWarning:
===============
105: gotDMITxBiasLowOverWarning: To detect whether TX Bias current is below low warning level or not.
106: gotDMITxBiasLowFallWarning:
===============
107: gotDMITxPowerHighOverAlarm: To detect whether TX output power exceeds high alarm level or not.
108: gotDMITxPowerHighFallAlarm:
===============
109: gotDMITxPowerLowOverAlarm: To detect whether TX output power is below low alarm level or not.
110: gotDMITxPowerLowFallAlarm:
===============
111: gotDMITxPowerHighOverWarning: To detect whether TX output power exceeds high warning level or not.
112: gotDMITxPowerHighFallWarning:
===============
113: gotDMITxPowerLowOverWarning: To detect whether TX output power is below low warning level or not.
114: gotDMITxPowerLowFallWarning:
===============
115: gotDMIRxPowerHighOverAlarm: To detect whether RX output power exceeds high alarm level or not.
116: gotDMIRxPowerHighFallAlarm:
===============
117: gotDMIRxPowerLowOverAlarm: To detect whether RX output power is below low alarm level or not.
118: gotDMIRxPowerLowFallAlarm:
===============
119: gotDMIRxPowerHighOverWarning: To detect whether RX output power exceeds high warning level or not.
120: gotDMIRxPowerHighFallWarning:
===============
121: gotDMIRxPowerLowOverWarning: To detect whether RX output power is below low warning level or not.
122: gotDMIRxPowerLowFallWarning:
===============
123: nosRemoteUpgradeRequest:
124: nosRemoteUpgradeSuccess:
125: nosRemoteUpgradeFailAbort:
126: nosRemoteUpgradeFailHeaderError:
127: nosRemoteUpgradeFailDownloadError:
128: nosRemoteUpgradeFailFlashError:
129: nosRemoteUpgradeStart:
===============
130: systemDyingGasp:
===============
133: cliHistory: To detect whether CLI history is detected or not.
134: cliHistoryNo:
===============
135: ntpConnectionFail: To detect whether NTP connection is failed or not.
136: ntpConnectionFailNo:
===============
137: nmsConnectionTypeChanged: To detect whether NMS connection type is changed.
===============
159: clockModuleRemoved: To detect whether clock module is removed or installed.
160: clockModuleInstalled:
161: clockModuleInitFail: To detect whether clock module initiolization is failed or not.
162: clockModuleInitOk:
===============
163: cliHistoryLog: To detect whether CLI history log is over or not.
164: cliHistoryLogNo:
===============
165: slotActionEvent: To detect whether slot action is changed.
166: slotStateChange: To detect whether slot state is changed.
===============
167: interfaceAdminDown: To detect whether physical or logical interface's admin link status is up or down.
168: interfaceAdminUp:
===============
169: slotPowerMonAbnormal: To detect whether slot power monitor abnormal or normal is detected.
170: slotPowerMonNormal:
===============
171: slotErrorLEDChanged: To detect whether error LED is changed.
===============
185: cpuPpsOverThreshold: To detect whether PPS is over threshold or not.
186: cpuPpsUnderThreshold:
===============
199: slotHealthStatusTimeout: To detect whether slot health status is time out or not.
200: slotHealthStatusTimeoutCleared:
===============
201: advaTemperature: To detect whether current chassis temperature is less than chassis temperature threshold or not.
202: advaTemperatureNo:
===============
203: advaPSUFailure: To detect whether ADVA system's power supply unit has a failure or not.
204: advaPSUFailureNo:
===============
205: advaFanFailure: To detect whether ADVA system's FAN has a failure or not.
206: advaFanFailureNo:
===============
207: advaInterfaceReceiveFailure: To detect whether ADVA system's receipt has a failure or not.
208: advaInterfaceReceiveFailureNo:
===============
209: advaInterfaceOpticalThreshold: To detect whether Adva system's optical receive power level is
less than optical threshold or not.
210: advaInterfaceOpticalThresholdNo:
===============
211: advaInterfaceTransmitFault: To detect whether ADVA system's transmission has a failure or not.
212: advaInterfaceTransmitFaultNo:
===============
213: dvaInterfaceMisconfiguration: To detect whether ADVA system's interface is configured rightly or not.
214: advaInterfaceMisconfigurationNo:
===============
215: advaInterfaceSFPMismatch: To detect whether ADVA system's SFP interface is mismatched or not.
216: advaInterfaceSFPMismatchNo:
===============
217: advaVoltageLow: To detect whether ADVA system's current voltage is less than voltage threshold or not.
218: advaVoltageLowNo:
===============
219: advaVoltageHigh: To detect whether ADVA system's current voltage is greater than voltage threshold or not.
220: advaVoltageHighNo:
===============
301: erpDomainLotp: To detect whether LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a node does not receive
any test packet at any of its ports for a period of 3 times.
302: erpDomainLotpNo:
===============
303: erpDomainULotp: To detect whether undirectional LOTP(Loss of Test Packet) exists a domain of ERP or not.
The Loss of Test Packet defect is defined when a RM node of one domain does not
receive any test packet at one port for a period of 3 times.
304: erpDomainULotpNo:
===============
305: erpDomainMultipleRM: To detect whether Multiple RM node is supported or not.
The defect is raised when a RM node receives its own test packets
with an Ack destination address field with a non-zero value.
306: erpDomainMultipleRMNo:
===============
307: erpDomainRMNodeReacheablity: To detect whether RM reachability is raised or not.
The detection of multiple failures indicates that the ring is segmented and
that the RM Node is unreacheable.
This is only possible at normal ring nodes isolated from the RM node.
308: erpDomainRMNodeReacheablityNo:
===============
391: startupConfigLoadEnded: To detect whether startup configuration load is ended.
===============
401: eponOnuDeregister: To detect whether ONU is registered into OLT or not.
That is, ONU that its operation is service on should be sent registration information to OLT.
402: eponOnuRegister:
===============
403: eponOnuRegistrationError: To detect whether ONU is failed registeration process into OLT.
404: eponOnuNoRegistrationError:
===============
405: eponBadEncryptionKey: To detect wwhether the encryption key is valid or not.
A message between ONU and OLT is encrypted using random encryption key.
There is that the encryption key is invalid as transmission failure from time to time.
406: eponNoBadEncryptionKey:
===============
407: eponLlidMistmatch: To detect whether Llid of message between ONU and OLT is valid or not.
On registering, ONU informs unique ID to OLT.
And then, all communication between ONU and OLT must use the unique ID.
The unique ID is called Llid.
408: eponNoLlidMismatch:
===============
409: eponTooManyRegister: To detect whether the registered ONU per 1 OLT is greater than 32 or not.
That is, ONU can be registered from 1 to the maximum 32 at 1 OLT.
410: eponNoTooManyRegister:
===============
411: eponDyingGASP: To detect whether a ONU is down from dying gasp or not.
A ONU could be changed to down state as a number of reasons.
By the way, ONU that is changed to down as dying gasp would be sent dying gasp signal to OLT and
then ONU's link would be changed to down.
412: eponNoDyingGASP:
===============
413: eponOnuErrFramePeriod:
414: eponOnuNoErrFramePeriod:
===============
415: eponOnuErrFrame:
416: eponOnuNoErrFrame:
===============
417: eponOnuErrFrameSecondSummary:
418: eponOnuNoErrFrameSecondSummary:
===============
419: eponOnuLastOnuDeregister: To detect whether a deregistered ONU is last ONU or not.
If a deregistered ONU is last ONU, the OLT would be changed to serviceable status.
420: eponOnuNoLastOnuDeregister:
===============
421: eponOltCableDown:
422: eponOltRecoverCableDown:
===============
501: autoCLIStart: To detect whether the scheduled auto CLI is started or not.
502: autoCLINoStart:
===============
503: autoCLIComplete: To detect whether the scheduled auto CLI is completed or not.
504: autoCLINoComplete:
===============
505: autoCLIRemoveOutputFile: To detect whether the result file of the scheduled auto CLI is removed or not.
The reason that the result file is removed is that the configured file size for the result is
less than the stored result file size.
If so, the oldest file would be removed before everything.
506: autoCLINoRemoveOutputFile:
===============
507: autoResetSystem: To detect whether the system is restarted or not.
The conditions that system is restarted is that ping loss threshold is
less than current ping loss count during the configured interval and
that current free memory size is less than configured free memory size.
508: autoResetNoSystem:
===============
509: autoResetPingReplyLoss: To detect whether ping reply from the designated network node is received or not.
Operator designates any gateway system that can communicate to detect
current network environment.
System sends ICMP packet to the designated gateway system periodically.
If the system doesn't receive ping reply packet within any interval,
operator recognizes that the system can't communicate any more
because of some problems of the system.
510: autoResetNoPingReplyLoss:
===============
511: autoResetMemoryLeakDetect: To detect whether current free memory size is
less than the configured free memory size or not.
Periodically, free memory size is checked to confirm system availability.
512: autoResetNoMemoryLeakDetect:
===============
601: arulePacketDropDetect: To detect whether it is dropped some packet by arule or not.
602: arulePacketDropRelease:
===============
620: bME1CardNoDetect:
621: clearBME1CardNoDetect:
===============
622: bME1CardAFEerror:
623: clearBME1CardAFEerror:
===============
624: bME1CardIFEerror:
625: clearBME1CardIFEerror:
===============
626: bME1CardFWerror:
627: clearBME1CardFWerror:
===============
628: bME1CardPROVerror:
629: clearBME1CardPROVerror:
===============
630: bME1CrashDetect:
631: clearBME1CrashDetect:
===============
632: bME2CardNoDetect:
633: clearBME2CardNoDetect:
===============
634: bME2CardAFEerror:
635: clearBME2CardAFEerror:
===============
636: bME2CardIFEerror:
637: clearBME2CardIFEerror:
===============
638: bME2CardFWerror:
639: clearBME2CardFWerror:
===============
640: bME2CardPROVerror:
641: clearBME2CardPROVerror:
===============
642: bME2CrashDetect:
643: clearBME2CrashDetect:
===============
644: bME3CardNoDetect:
645: clearBME3CardNoDetect:
===============
646: bME3CardAFEerror:
647: clearBME3CardAFEerror:
===============
648: bME3CardIFEerror:
649: clearBME3CardIFEerror:
===============
650: bME3CardFWerror:
651: clearBME3CardFWerror:
===============
652: bME3CardPROVerror:
653: clearBME3CardPROVerror:
===============
654: bME3CrashDetect:
655: clearBME3CrashDetect:
===============
656: powerFromBattery:
657: clearPowerFromBattery:
===============
658: invalidBatteryStatus:
659: clearInvalidBatteryStatus:
===============
660: batteryChargeLow:
661: clearBatteryChargeLow:
===============
662: batteryNotPresent:
663: clearBatteryNotPresent:
===============
664: voltageLow:
665: clearVoltageLow:
===============
666: tempOverThreshold:
667: clearTempOverThreshold:
===============
668: tempUnderThreshold:
669: clearTempUnderThreshold:
===============
670: cpuOverThreshold:
671: clearCpuOverThreshold:
===============
672: trafficOverload:
673: clearTrafficOverload:
===============
674: gEPONModuleNotDetect:
675: clearGEPONModuleNotDetect:
===============
676: gEPONPortOperationDown:
677: clearGEPONPortOperationDown:
===============
678: gEPONNoIncomingTraffic:
679: clearGEPONNoIncomingTraffic:
===============
680: processCrashDetect:
681: clearProcessCrashDetect:
===============
682: memoryLeakDetect:
683: clearMemoryLeakDetect:
===============
684: memoryCorrupDetect:
685: clearMemoryCorrupDetect:
===============
686: memoryLowDetect:
687: clearMemoryLowDetect:
===============
688: dataLineerror:
689: clearDataLineerror:
===============
690: addressLineerror:
691: clearAddressLineerror:
===============
692: chipsetNotDetcet:
693: clearChipsetNotDetcet:
===============
694: pciBuserror:
695: clearPciBuserror:
===============
696: securityAdminConnect:
697: clearSecurityAdminConnect:
===============
698: oNUPowerDown:
699: clearONUPowerDown:
===============
700: oNUNotRegister:
701: clearONUNotRegister:
===============
702: oNTOpticPre:
703: clearONTOpticPre:
===============
800: switchoverInitiated:
===============
801: switchoverDone:
===============
803: redConfigurationMisMatch: To detect whether redundancy configuration is mismatched.
===============
901: gponNoAuthCBU: To detect no auth CBU is detected.
902: gponDuplicateONU: To detect ONU is duplicated.
903: gponDyingGasp: To detect dying GASP is detected.
904: gponUpgradeComplete: To detect upgrade complete is detected.
905: gponDeregistered: To detect whether deregistered is detected or not.
906: gponRegistered:
907: gponRogueOnu: To detect rogue ONU is detected
908: gponOnuBatteryEvent: To detect whether ONU battery event is detected or not.
909: clearGponOnuBetteryEvent:
910: gponOnuPortOperStatus: To detectONU port operation statue is chagned.
911: gponTransceiverChanged: To detect transceiver is changed.
912: gponOltLosOn: To detect whether OLT LOS is on or off
913: gponOltLosOff:
914: gponOltLosiOn: To detect whether OLT LOSI is on or off
915: gponOltLosiOff:
916: gponDyingGaspOn: To detect whether dying GASP is on or off
917: gponDyingGaspOff:
918: gponOntOSUpgradeStatus: To detect ONT OS upgrade status is changed.
919: gponOntBLUpgradeStatus: To detect BL upgrade status is changed.
920: gponOltRxPowerLoss: To detect OLT RX power is loss.
921: gponOltRxPowerDetected: To detect OLT RX power status is changed.
922: gponOnuTemperatureHighOverThreshold: To detect whether ONU temperature exceeds high threshold or not.
923: gponOnuTemperatureHighFallThreshold:
924: gponOnuTemperatureLowOverThreshold: To detect whether ONU temperature belows low threshold or not.
925: gponOnuTemperatureLowFallThreshold:
926: gponOnuCpuOverThreshold: To detect whether ONU CPU exceeds threshold or not.
927: gponOnuCpuFallThreshold:
928: gponOnuMemoryOverThreshold: To detect whether memory exceeds threshold or not.
929: gponOnuMemoryFallThreshold:
930: gponOnuI2cFail: To detect ONU L2C fail is detected.
931: gponOnuRxOpticLowThreshAlarmOn: To detect whether ONU RX optic belows low threshold or not.
932: gponOnuRxOpticLowThreshAlarmOff:
933: gponOnuRxOpticHighThreshAlarmOn: To detect whether ONU RX optic exceeds high threshold or not.
934: gponOnuRxOpticHighThreshAlarmOff:
935: gponOltLOFIOn: To detect whether OLT LOFL is on or off
936: gponOltLOFIOff:
937: gponOltDOWOn: To detect whether OLT DOW is on or off
938: gponOltDOWOff:
939: gponOltSFOn: To detect whether OLT SF is on or off
940: gponOltSFOff:
941: gponOltSDOn: To detect whether OLT SD is on or off
942: gponOltSDOff:
943: gponOltLCDGIOn: To detect whether OLT LCDGL is on or off
944: gponOltLCDGIOff:
945: gponOltRDOn: To detect whether OLT RD is on or off
946: gponOltRDOff:
947: gponOltSUFOn: To detect whether OLT SUF is on or off
948: gponOltSUFOff:
949: gponOltLOAOn: To detect whether OLT LOA is on or off
950: gponOltLOAOff:
951: gponOltLOAMIOn: To detect whether OLT LOAML is on or off
952: gponOltLOAMIOff:
953: gponOltMEMOn: To detect whether OLT MEM is on or off
954: gponOltMEMOff:
955: gponOltPEEOn: To detect whether OLT PEE is on or off
956: gponOltPEEOff:
957: gponOltPSTOn: To detect whether OLT PST is on or off
958: gponOltPSTOff:
959: gponOltERROn: To detect whether OLT ERR is on or off
960: gponOltERROff:
961: gponOltREIOn: To detect whether OLT REI is on or off
962: gponOltREIOff:
963: gponAntiSpoofingDupPortOn: To detect whether anti spoofing port is duplicated or not.
964: gponAntiSpoofingDupPortOff:
965: gponRedundancySwitchOver: To detect redundancy switchover is changed.
966: gponDuplicatedRangingResponse: To detect ranging response is changed.
967: gponOnuPortOpticModuleRemove: To detect whether ONU port optic module is removed or installed.
968: gponOnuPortOpticModuleInstall:
969: gponOnuOMCCProblemDetected: To detect whether ONU OMCC problem is detected or not.
970: gponOnuOMCCProblemCleared:
971: gponOltFixedTcontAlarmOn: To detect whether OLT fixed Tcont alarm is on or off.
972: gponOltFixedTcontAlarmOff:
973: gponOltDynamicTcontAlarmOn: To detect whether OLT dynamic Tcont alarm is on or off.
974: gponOltDynamicTcontAlarmOff:
975: gponOltPortCountAlarmOn: To detect whether OLT port count alarm is on or off.
976: gponOltPortCountAlarmOff:
977: gponOltCableDownAlarmOn: To detect whether OLT cable down alarm is on or off.
978: gponOltCableDownAlarmOff:
979: gponOltDeactiveMonitorAlarmOn: To detect whether deactive monitor alarm is on or off.
980: gponOltDeactiveMonitorAlarmOff:
981: gponOltDfiOn: To detect whether OLT DFI is on or off.
982: gponOltDfiOff:
984: gponOltTransceiverPortChanged: To detect OLT transeiver port is changed.
985: gponOnuPortOperStatusDown: To detect whether ONU port operation status is down or up.
986: gponOnuPortOperStatusUp::
===============
1101: emLogDefectCPUHighOver: To detect whether EM log detect CPU exceeds threshold or not.
1102: emLogDefectCPUHighUnder:
1103: emLogTemperHighOver: To detect whether EM log temperature exceeds high threshold or not.
1104: emLogTemperHighUnder:
1105: emLogTemperLowUnder: To detect whether EM log CPU belows low threshold or not.
1106: emLogTemperLowOver:
1107: emLogMemLowUnder: To detect whether EM log memory belows low threshold or not.
1108: emLogMemLowOver:
1109: emLogFanFail: To detect whether EM log fan status is failed or not.
1110: emLogFanFailCleared:
1111: emLogPhyCRCFail: To detect whether EM log physical CRC is failed or not.
1112: emLogPhyCRCFailCleared:
1113: emLogPhyDetectFail: To detect whether EM log physical status is failed or not.
1114: emLogPhyDetectFailCleared:
1115: emLogSFUMateInitFail: To detect whether EM log SFU mate initialization is failed or not.
1116: emLogSFUMateInitFailCleared:
1117: emLogDaemonHealthBad: To detect whether EM log daemon health is bad or not.
1118: emLogDaemonHealthBadCleared:
1119: emLogGPIURavenLinkDown: To detect whether EM log GPIU RAVEN link is down or not.
1120: emLogGPIURavenLinkDownCleared:
===============
1151: slotNosUpgradeStart: To detect whether slot NOS upgrade is started or ended.
1152: slotNosUpgradeEnd:
===============
1331: gponOnuAniVoltageLowThreshAlarmOn: To detect whether ONU ANI voltage belows low threshold or not.
1332: gponOnuAniVoltageLowThreshAlarmOff:
1333: gponOnuAniVoltageHighThreshAlarmOn: To detect whether ONU ANI voltage exceeds high threshold or not.
1334: gponOnuAniVoltageHighThreshAlarmOff:
1335: gponOnuAniTemperatureLowThreshAlarmOn: To detect whether ONU ANI temperature belows low threshold or not.
1336: gponOnuAniTemperatureLowThreshAlarmOff:
1337: gponOnuAniTemperatureHighThreshAlarmOn: To detect whether ONU ANI temperature exceeds high threshold or not.
1338: gponOnuAniTemperatureHighThreshAlarmOff:
1339: gponOnuAniTxBiasLowThreshAlarmOn: To detect whether ONU ANI TX bias belows low threshold or not.
1340: gponOnuAniTxBiasLowThreshAlarmOff:
1341: gponOnuAniTxBiasHighThreshAlarmOn: To detect whether ONU ANI TX bias exceeds high threshold or not.
1342: gponOnuAniTxBiasHighThreshAlarmOff:
1343: gponOnuAniTxpowerLowThreshAlarmOn: To detect whether ONU ANI TX power belows low threshold or not.
1344: gponOnuAniTxpowerLowThreshAlarmOff:
1345: gponOnuAniTxpowerHighThreshAlarmOn: To detect whether ONU ANI TX power exceeds high threshold or not.
1346: gponOnuAniTxpowerHighThreshAlarmOff:"
::= { sleAlarmHistoryEntry 2 }
sleAlarmHistorySeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleAlarmHistoryEntry 3 }
sleAlarmHistoryText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of specific problem reported by alarming.
To be discussed: Option is to define an alarm for every problem
"
::= { sleAlarmHistoryEntry 4 }
sleAlarmHistoryTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The severity of alarm. "
::= { sleAlarmHistoryEntry 5 }
sleAlarmHistorySeqNum OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sequence number for the alarm synchronization.
This value has a number to be used for the next alarm trap."
::= { sleAlarmHistoryEntry 6 }
sleAlarmHistoryPairType OBJECT-TYPE
SYNTAX INTEGER
{
pair(0),
mono(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type is whether alarm trap is pair or mono."
::= { sleAlarmHistoryEntry 7 }
sleAlarmHistoryControl OBJECT IDENTIFIER ::= { sleAlarmHistory 2 }
sleAlarmHistoryControlRequest OBJECT-TYPE
SYNTAX INTEGER { clearAlarmHistory(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This attribute identifies the control commands.
updateAlarmList:
the NE updates entries of alarms in the sleAlarmListTable
after having changed alarm severities of alarms
(due to change profile pointers in
managed entities or after modification of alarm severities
in profiles). This command should be applied once after having
finisled modifications of severties.
modifyAlarmSeverity:
modifies the severity of an alarm in specific profile.
createAlarmSeverityProfile:
creates a new profile with default severities.
The severities then have to be modified with command changeAlarmSeverity.
deleteAlarmSeverityProfile:
deletes a profile. Profile 1 is not allowed to be deleted.
Notifications : none "
::= { sleAlarmHistoryControl 1 }
sleAlarmHistoryControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleAlarmHistoryControl 2 }
sleAlarmHistoryControlTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleAlarmHistoryControl 3 }
sleAlarmHistoryControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleAlarmHistoryControl 4 }
sleAlarmHistoryControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleAlarmHistoryControl 5 }
sleAlarmHistoryNotification OBJECT IDENTIFIER ::= { sleAlarmHistory 3 }
sleAlarmHistoryCleared NOTIFICATION-TYPE
OBJECTS { sleAlarmHistoryControlRequest, sleAlarmHistoryControlTimeStamp, sleAlarmHistoryControlReqResult }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmHistoryNotification 1 }
sleEfmOam OBJECT IDENTIFIER ::= { sleFaultMgmt 5 }
sleEfmOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleEfmOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOam 1 }
sleEfmOamEntry OBJECT-TYPE
SYNTAX SleEfmOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleOamPortIndex }
::= { sleEfmOamTable 1 }
SleEfmOamEntry ::=
SEQUENCE {
sleOamPortIndex
INTEGER,
sleOamMuxAction
INTEGER,
sleOamParAction
INTEGER,
sleOamAdminState
INTEGER,
sleOamMode
INTEGER,
sleOamUnidirectionMode
INTEGER,
sleOamFunctionsSupported
BITS,
sleOamPeerStatus
INTEGER,
sleOamPeerMacAddress
MacAddress,
sleOamPeerMode
INTEGER,
sleOamPeerFunctionsSupported
BITS,
sleOamRemLoopback
INTEGER,
sleOamRemLoopbackCnt
INTEGER,
sleOamLm
INTEGER,
sleOamLmAction
INTEGER,
sleOamLmFrameWindow
INTEGER,
sleOamLmFrameThresh
INTEGER,
sleOamLmFrameTotal
Counter64,
sleOamLmFramePeriodWindow
Integer32,
sleOamLmFramePeriodThresh
Integer32,
sleOamLmFramePeriodTotal
Counter64,
sleOamLmFrameSecondSummaryWindow
Integer32,
sleOamLmFrameSecondSummaryThresh
Integer32,
sleOamLmFrameSecondSummaryTotal
Counter64,
sleOamLmSymbolPeriodWindow
INTEGER,
sleOamLmSymbolPeriodThresh
INTEGER,
sleOamLmSymbolPeriodTotal
Counter64,
sleOamLmRemSeqNum
Integer32,
sleOamLmRemFrameLength
Integer32,
sleOamLmRemFrameTimeStamp
TimeTicks,
sleOamLmRemFrameWindow
Integer32,
sleOamLmRemFrameThresh
Integer32,
sleOamLmRemFrameErrors
Integer32,
sleOamLmRemFrameErrorRunTotal
Counter64,
sleOamLmRemFrameEventRunTotal
Integer32,
sleOamLmRemFramePeriodLength
Integer32,
sleOamLmRemFramePeriodTimeStamp
TimeTicks,
sleOamLmRemFramePeriodWindow
Integer32,
sleOamLmRemFramePeriodThresh
Integer32,
sleOamLmRemFramePeriodErrors
Integer32,
sleOamLmRemFramePeriodErrorRunTotal
Counter64,
sleOamLmRemFramePeriodEventRunTotal
Integer32,
sleOamLmRemFrameSecondSummaryLength
Integer32,
sleOamLmRemFrameSecondSummaryTimeStamp
TimeTicks,
sleOamLmRemFrameSecondSummaryWindow
Integer32,
sleOamLmRemFrameSecondSummaryThresh
Integer32,
sleOamLmRemFrameSecondSummaryErrors
Integer32,
sleOamLmRemFrameSecondSummaryErrorRunTotal
Integer32,
sleOamLmRemFrameSecondSummaryEventRunTotal
Integer32,
sleOamLmRemSymbolPeriodLength
Integer32,
sleOamLmRemSymbolPeriodTimeStamp
TimeTicks,
sleOamLmRemSymbolPeriodWindow
Counter64,
sleOamLmRemSymbolPeriodThresh
Counter64,
sleOamLmRemSymbolPeriodErrors
Counter64,
sleOamLmRemSymbolPeriodErrorRunTotal
Counter64,
sleOamLmRemSymbolPeriodEventRunTotal
Counter64
}
sleOamPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOamEntry 1 }
sleOamMuxAction OBJECT-TYPE
SYNTAX INTEGER
{
fwd(1),
discard(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value governs the flow of frames from
the MAC client to the Muliplexer function."
::= { sleEfmOamEntry 2 }
sleOamParAction OBJECT-TYPE
SYNTAX INTEGER
{
fwd(1),
lb(2),
discard(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value governs the flow of non-OAMPDUs
within the Parser function."
::= { sleEfmOamEntry 3 }
sleOamAdminState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to provision the default
administrative OAM mode for this interface."
::= { sleEfmOamEntry 4 }
sleOamMode OBJECT-TYPE
SYNTAX INTEGER
{
passive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object configures the mode of OAM
operation for this Ethernet like interface."
::= { sleEfmOamEntry 5 }
sleOamUnidirectionMode OBJECT-TYPE
SYNTAX INTEGER
{
notAvaliable(-2),
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOamEntry 6 }
sleOamFunctionsSupported OBJECT-TYPE
SYNTAX BITS
{
unidirectionalSupport(0),
loopbackSupport(1),
eventSupport(2),
variableSupport(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM functions supported on this
Ethernet like interface."
::= { sleEfmOamEntry 7 }
sleOamPeerStatus OBJECT-TYPE
SYNTAX INTEGER
{
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether the information
in this row should be considered valid."
::= { sleEfmOamEntry 8 }
sleOamPeerMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the peer OAM entity."
::= { sleEfmOamEntry 9 }
sleOamPeerMode OBJECT-TYPE
SYNTAX INTEGER
{
passive(0),
active(1),
unknown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mode Info of the OAM peer as reflected
in the latest Information OAMPDU received with
a Local Information TLV."
::= { sleEfmOamEntry 10 }
sleOamPeerFunctionsSupported OBJECT-TYPE
SYNTAX BITS
{
unidirectionalSupport(0),
loopbackSupport(1),
eventSupport(2),
variableSupport(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM functions supported on this
Ethernet like interface."
::= { sleEfmOamEntry 11 }
sleOamRemLoopback OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOamEntry 12 }
sleOamRemLoopbackCnt OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of test Packet"
::= { sleEfmOamEntry 13 }
sleOamLm OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates whether Link-Monitor supports or not for port index."
::= { sleEfmOamEntry 14 }
sleOamLmAction OBJECT-TYPE
SYNTAX INTEGER
{
syslog(0),
snmpTrap(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Action of Link-Monitor for port index."
::= { sleEfmOamEntry 15 }
sleOamLmFrameWindow OBJECT-TYPE
SYNTAX INTEGER (10..600)
UNITS "100 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Window size of Errored Frame.
Default : 10, Unit : 100ms
"
::= { sleEfmOamEntry 16 }
sleOamLmFrameThresh OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Threshold size of Errored Frame.
Default: 1
"
::= { sleEfmOamEntry 17 }
sleOamLmFrameTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Count of Errored Frame"
::= { sleEfmOamEntry 18 }
sleOamLmFramePeriodWindow OBJECT-TYPE
SYNTAX Integer32 (1000..200000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is size of Errored Period Window.
Default : 1000000 frames
"
::= { sleEfmOamEntry 19 }
sleOamLmFramePeriodThresh OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is size of Errored Period Threshold.
Default : 10
"
::= { sleEfmOamEntry 20 }
sleOamLmFramePeriodTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Count of Errored Period Frame"
::= { sleEfmOamEntry 21 }
sleOamLmFrameSecondSummaryWindow OBJECT-TYPE
SYNTAX Integer32 (10..900)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Window size of errored frame in a second
Default : 60 secs
"
::= { sleEfmOamEntry 22 }
sleOamLmFrameSecondSummaryThresh OBJECT-TYPE
SYNTAX Integer32 (0..900)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Threshold size of errored frame in a second
Default: 1
"
::= { sleEfmOamEntry 23 }
sleOamLmFrameSecondSummaryTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Count of Errored Frame Second"
::= { sleEfmOamEntry 24 }
sleOamLmSymbolPeriodWindow OBJECT-TYPE
SYNTAX INTEGER (1..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the window size of symbol errors.
Default: 625 millions, Unit: 1 million
"
::= { sleEfmOamEntry 25 }
sleOamLmSymbolPeriodThresh OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Threshold size of symbol errors
Default : 1
"
::= { sleEfmOamEntry 26 }
sleOamLmSymbolPeriodTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Count of Symbol errors"
::= { sleEfmOamEntry 27 }
sleOamLmRemSeqNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Sequence Number for event"
::= { sleEfmOamEntry 28 }
sleOamLmRemFrameLength OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Length of Errored Frame"
::= { sleEfmOamEntry 29 }
sleOamLmRemFrameTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the TimeStamp of Errored Frame"
::= { sleEfmOamEntry 30 }
sleOamLmRemFrameWindow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Window Size of Errored Frame"
::= { sleEfmOamEntry 31 }
sleOamLmRemFrameThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Threshold Size of Errored Frame"
::= { sleEfmOamEntry 32 }
sleOamLmRemFrameErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Count of Errored Frame"
::= { sleEfmOamEntry 33 }
sleOamLmRemFrameErrorRunTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Frame"
::= { sleEfmOamEntry 34 }
sleOamLmRemFrameEventRunTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Frame Event"
::= { sleEfmOamEntry 35 }
sleOamLmRemFramePeriodLength OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Length of Errored Frame Period"
::= { sleEfmOamEntry 36 }
sleOamLmRemFramePeriodTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the TimeStamp of Errored Frame Period"
::= { sleEfmOamEntry 37 }
sleOamLmRemFramePeriodWindow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Window Size of Errored Frame Period"
::= { sleEfmOamEntry 38 }
sleOamLmRemFramePeriodThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Threshold Size of Errored Frame Period"
::= { sleEfmOamEntry 39 }
sleOamLmRemFramePeriodErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Count of Errored Frame Period"
::= { sleEfmOamEntry 40 }
sleOamLmRemFramePeriodErrorRunTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Frame Period"
::= { sleEfmOamEntry 41 }
sleOamLmRemFramePeriodEventRunTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Frame Period Event"
::= { sleEfmOamEntry 42 }
sleOamLmRemFrameSecondSummaryLength OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Length of Errored Frame Second Summary"
::= { sleEfmOamEntry 43 }
sleOamLmRemFrameSecondSummaryTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the TimeStamp of Errored Frame Second Summary"
::= { sleEfmOamEntry 44 }
sleOamLmRemFrameSecondSummaryWindow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Window size of Errored Frame Second Summary"
::= { sleEfmOamEntry 45 }
sleOamLmRemFrameSecondSummaryThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Threshold size of Errored Frame Second Summary"
::= { sleEfmOamEntry 46 }
sleOamLmRemFrameSecondSummaryErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Count of Errored Frame Second Summary"
::= { sleEfmOamEntry 47 }
sleOamLmRemFrameSecondSummaryErrorRunTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Frame Second Summary"
::= { sleEfmOamEntry 48 }
sleOamLmRemFrameSecondSummaryEventRunTotal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Frame Second Summary Event"
::= { sleEfmOamEntry 49 }
sleOamLmRemSymbolPeriodLength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Length of Errored Symbols"
::= { sleEfmOamEntry 50 }
sleOamLmRemSymbolPeriodTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the TimeStamp of Errored Symbols"
::= { sleEfmOamEntry 51 }
sleOamLmRemSymbolPeriodWindow OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Window size of Errored Symbols"
::= { sleEfmOamEntry 52 }
sleOamLmRemSymbolPeriodThresh OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Threshold size of Errored Symbols"
::= { sleEfmOamEntry 53 }
sleOamLmRemSymbolPeriodErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Count of Errored Symbols"
::= { sleEfmOamEntry 54 }
sleOamLmRemSymbolPeriodErrorRunTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Symbols"
::= { sleEfmOamEntry 55 }
sleOamLmRemSymbolPeriodEventRunTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the Total Count of Errored Symbols Event"
::= { sleEfmOamEntry 56 }
sleEfmOamControl OBJECT IDENTIFIER ::= { sleEfmOam 2 }
sleOamControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setEfmOamPortProfile(1),
setEfmOamPortRemLoopback(2),
setEfmOamPortLinkMonitor(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MIB object for the user command.."
::= { sleEfmOamControl 1 }
sleOamControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the status of a user command group,
used for block commands while a command execution in process."
::= { sleEfmOamControl 2 }
sleOamControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum command duration time in case of long running"
::= { sleEfmOamControl 3 }
sleOamControlTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time stamp attribute set at end of command."
::= { sleEfmOamControl 4 }
sleOamControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Command result attribute"
::= { sleEfmOamControl 5 }
sleOamControlIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOamControl 6 }
sleOamControlPortAdminState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to provision the default
administrative OAM mode for this interface."
::= { sleEfmOamControl 7 }
sleOamControlPortMode OBJECT-TYPE
SYNTAX INTEGER
{
passive(0),
active(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the mode of OAM
operation for this Ethernet like interface."
::= { sleEfmOamControl 8 }
sleOamControlPortUnidirectionMode OBJECT-TYPE
SYNTAX INTEGER
{
notAvaliable(-2),
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOamControl 9 }
sleOamControlPortRemLoopback OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value indicates an optional data link
layer frame-level loopback mode, which is
controlled remotely."
::= { sleEfmOamControl 10 }
sleOamControlRemLoopbackPkCnt OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of test Packet"
::= { sleEfmOamControl 11 }
sleOamControlLm OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates whether Link-Monitor supports or not for port index."
::= { sleEfmOamControl 12 }
sleOamControlLmAction OBJECT-TYPE
SYNTAX INTEGER
{
syslog(0),
snmpTrap(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Action of Link-Monitor for port index."
::= { sleEfmOamControl 13 }
sleOamControlLmFrameWindow OBJECT-TYPE
SYNTAX INTEGER (10..600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the Window size of Errored Frame.
Default : 30 secs
"
::= { sleEfmOamControl 14 }
sleOamControlLmFrameThresh OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the Threshold size of Errored Frame.
Default: 1
"
::= { sleEfmOamControl 15 }
sleOamControlLmFramePeriodWindow OBJECT-TYPE
SYNTAX INTEGER (1000..200000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is size of Errored Period Window.
Default : 1000000 frames
"
::= { sleEfmOamControl 16 }
sleOamControlLmFramePeriodThresh OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is size of Errored Period Threshold.
Default : 10
"
::= { sleEfmOamControl 17 }
sleOamControlLmFrameSecondSummaryWindow OBJECT-TYPE
SYNTAX INTEGER (10..900)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the Window size of errored frame in a second
Default : 60 secs
"
::= { sleEfmOamControl 18 }
sleOamControlLmFrameSecondSummaryThresh OBJECT-TYPE
SYNTAX INTEGER (0..900)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the Threshold size of errored frame in a second
Default: 1
"
::= { sleEfmOamControl 19 }
sleOamControlLmSymbolPeriodWindow OBJECT-TYPE
SYNTAX INTEGER (1..1000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the window size of symbol errors.
Default: 625 millions, Unit: 1 million
"
::= { sleEfmOamControl 20 }
sleOamControlLmSymbolPeriodThresh OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is the Threshold size of symbol errors
Default : 1
"
::= { sleEfmOamControl 21 }
sleEfmOamNotification OBJECT IDENTIFIER ::= { sleEfmOam 3 }
sleEfmOamPortProfileChanged NOTIFICATION-TYPE
OBJECTS { sleOamControlReqResult, sleOamControlTimeStamp, sleOamControlRequest, sleOamAdminState, sleOamMode,
sleOamUnidirectionMode }
STATUS current
DESCRIPTION
" "
::= { sleEfmOamNotification 1 }
sleEfmOamPortRemLoopback NOTIFICATION-TYPE
OBJECTS { sleOamControlRequest, sleOamControlReqResult, sleOamControlTimeStamp, sleOamRemLoopback, sleOamControlRemLoopbackPkCnt
}
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOamNotification 2 }
sleEfmOamPortLinkMonitorChanged NOTIFICATION-TYPE
OBJECTS { sleOamControlRequest, sleOamControlReqResult, sleOamControlTimeStamp, sleOamLmFramePeriodThresh, sleOamLmFramePeriodWindow,
sleOamLmFrameThresh, sleOamLmFrameWindow, sleOamLmAction, sleOamLmSymbolPeriodThresh, sleOamLmSymbolPeriodWindow,
sleOamLmFrameSecondSummaryThresh, sleOamLmFrameSecondSummaryWindow, sleOamLm, sleOamPortIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleEfmOamNotification 3 }
sleAdvaSystem OBJECT IDENTIFIER ::= { sleFaultMgmt 6 }
sleAdvaSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAdvaSystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystem 1 }
sleAdvaSystemEntry OBJECT-TYPE
SYNTAX SleAdvaSystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleOamPortIndex }
::= { sleAdvaSystemTable 1 }
SleAdvaSystemEntry ::=
SEQUENCE {
sleAdvaFSPOperationMode
INTEGER,
sleAdvaActiveNetworkInterface
INTEGER,
sleAdvaForceNetworkInterface
INTEGER,
sleAdvaReportingInterval
INTEGER,
sleAdvaNEMIFitted
INTEGER,
sleAdvaForceReset
INTEGER,
sleAdvaManagerAddress
IpAddress,
sleAdvaMinRailVoltageThreshold
INTEGER,
sleAdvaMaxRailVoltageThreshold
INTEGER,
sleAdvaTemperatureThreshold
INTEGER,
sleAdvaPartNumber
OCTET STRING,
sleAdvaSerialNumber
OCTET STRING,
sleAdvaFirmwareVersion
OCTET STRING,
sleAdvaFPGAVersion
OCTET STRING,
sleAdvaHardwareRevision
OCTET STRING,
sleAdvaCLEICode
OCTET STRING,
sleAdvaTemperature
INTEGER,
sleAdvaRailVoltage
INTEGER,
sleAdvaPSUStates
INTEGER,
sleAdvaPSUType
INTEGER,
sleAdvaFansFitted
INTEGER,
sleAdvaFanState
INTEGER,
sleAdvaTransmitMode
INTEGER
}
sleAdvaFSPOperationMode OBJECT-TYPE
SYNTAX INTEGER
{
master(1),
slave(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mode in which the FSP 150 is to operate"
::= { sleAdvaSystemEntry 1 }
sleAdvaActiveNetworkInterface OBJECT-TYPE
SYNTAX INTEGER
{
both(0),
portA(1),
portB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which of the network interfaces is the active one"
::= { sleAdvaSystemEntry 2 }
sleAdvaForceNetworkInterface OBJECT-TYPE
SYNTAX INTEGER
{
unforced(0),
forceA(1),
forceB(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemEntry 3 }
sleAdvaReportingInterval OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Repeat period in 1/10th seconds for Organisation Specific Alarm
Status OAMPDU. If non-zero and there are any alarms active,
repeat the last-sent AS after this interval from when it was
last sent.If zero then only send on changes.As a special action,
writing zero to this will cause the Alarm Status OAMPDU to be sent (poll)."
::= { sleAdvaSystemEntry 4 }
sleAdvaNEMIFitted OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator as to whether a NEMI is fitted."
::= { sleAdvaSystemEntry 5 }
sleAdvaForceReset OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Writing True (1) causes the system to be reset."
::= { sleAdvaSystemEntry 6 }
sleAdvaManagerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the Management station monitoring this sytem."
::= { sleAdvaSystemEntry 7 }
sleAdvaMinRailVoltageThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Threshold in mV below which the Voltage low alarm will be
activated. (Alarm Configuration)"
::= { sleAdvaSystemEntry 8 }
sleAdvaMaxRailVoltageThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Threshold in mV above which the Voltage high alarm will be activated.
(Alarm Configuration)"
::= { sleAdvaSystemEntry 9 }
sleAdvaTemperatureThreshold OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Threshold in C above which the Temperature alarm will be activated. (Alarm Configuration)"
::= { sleAdvaSystemEntry 10 }
sleAdvaPartNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Part number for the chassis. (Chassis)"
::= { sleAdvaSystemEntry 11 }
sleAdvaSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number for the chassis. (Chassis)"
::= { sleAdvaSystemEntry 12 }
sleAdvaFirmwareVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Firmware version for the chassis. (Chassis)
(0-length string if unknown)."
::= { sleAdvaSystemEntry 13 }
sleAdvaFPGAVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FPGA version for the chassis. (Chassis)
(0-length string if unknown)."
::= { sleAdvaSystemEntry 14 }
sleAdvaHardwareRevision OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware revision for the chassis.
(Chassis)(0-length string if unknown)."
::= { sleAdvaSystemEntry 15 }
sleAdvaCLEICode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..14))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CLEI for the chassis. (Chassis)"
::= { sleAdvaSystemEntry 16 }
sleAdvaTemperature OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current chassis temperature in degrees C. (Chassis)"
::= { sleAdvaSystemEntry 17 }
sleAdvaRailVoltage OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current DC power rail voltage (mV). (Chassis)"
::= { sleAdvaSystemEntry 18 }
sleAdvaPSUStates OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit-mask representing the state of the PSUs.
Starting at the LSB, each failed PSU is indicated
by a bit set to '1'. (Chassis)"
::= { sleAdvaSystemEntry 19 }
sleAdvaPSUType OBJECT-TYPE
SYNTAX INTEGER
{
ac(1),
dc(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of PSUs fitted. (Chassis)"
::= { sleAdvaSystemEntry 20 }
sleAdvaFansFitted OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit-mask representing which fans are fitted.
Starting at the LSB, each bit set to '1' indicates a fitted fan.
Knowledge of which fans ought to be fitted is assumed. (Chassis)"
::= { sleAdvaSystemEntry 21 }
sleAdvaFanState OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit-mask representing the state of the fan.
Starting at the LSB, each failed fan is indicated by a
bit set to '1'. (Chassis)"
::= { sleAdvaSystemEntry 22 }
sleAdvaTransmitMode OBJECT-TYPE
SYNTAX INTEGER
{
halfDuplex(0),
fullDuplex(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Electrical Interface for remote instance 4"
::= { sleAdvaSystemEntry 23 }
sleAdvaSystemControl OBJECT IDENTIFIER ::= { sleAdvaSystem 2 }
sleAdvaSystemControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setAdvaSystemProfile(1),
setAdvaAlarmProfile(2),
setAdvaElectricalInterface(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MIB object for the user command.."
::= { sleAdvaSystemControl 1 }
sleAdvaSystemControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the status of a user command group,
used for block commands while a command execution in process."
::= { sleAdvaSystemControl 2 }
sleAdvaSystemControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 3 }
sleAdvaSystemControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 4 }
sleAdvaSystemControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 5 }
sleAdvaSystemControlPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 6 }
sleAdvaSystemControlFSPOperationMode OBJECT-TYPE
SYNTAX INTEGER
{
master(1),
save(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 7 }
sleAdvaSystemControlForceNetworkInterface OBJECT-TYPE
SYNTAX INTEGER
{
unforced(0),
forceA(1),
forceB(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 8 }
sleAdvaSystemControlReportingInterval OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 9 }
sleAdvaSystemControlForceReset OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 10 }
sleAdvaSystemControlMinRailVoltageThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 11 }
sleAdvaSystemControlMaxRailVoltageThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 12 }
sleAdvaSystemControlTemperatureThreshold OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 13 }
sleAdvaSystemControlTransmitMode OBJECT-TYPE
SYNTAX INTEGER
{
halfDuplex(0),
fullDuplex(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemControl 14 }
sleAdvaSystemNotification OBJECT IDENTIFIER ::= { sleAdvaSystem 3 }
sleAdvaSystemProfileChanged NOTIFICATION-TYPE
OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaFSPOperationMode, sleAdvaForceNetworkInterface,
sleAdvaReportingInterval, sleAdvaForceReset }
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemNotification 1 }
sleAdvaAlarmProfileChanged NOTIFICATION-TYPE
OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaMinRailVoltageThreshold, sleAdvaMaxRailVoltageThreshold,
sleAdvaTemperatureThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemNotification 2 }
sleAdvaElectricalInterfaceChanged NOTIFICATION-TYPE
OBJECTS { sleAdvaSystemControlRequest, sleAdvaSystemControlReqResult, sleAdvaSystemControlTimeStamp, sleAdvaTransmitMode }
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaSystemNotification 3 }
sleAdvaGeneral OBJECT IDENTIFIER ::= { sleFaultMgmt 7 }
sleAdvaGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAdvaGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneral 1 }
sleAdvaGeneralEntry OBJECT-TYPE
SYNTAX SleAdvaGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleOamPortIndex, sleAdvaRemInstance }
::= { sleAdvaGeneralTable 1 }
SleAdvaGeneralEntry ::=
SEQUENCE {
sleAdvaRemInstance
INTEGER,
sleAdvaOperationalStatus
INTEGER,
sleAdvaLineSpeed
Integer32,
sleAdvaMACAddress
MacAddress,
sleAdvaConnectorType
INTEGER,
sleAdvaAutonegiotation
INTEGER,
sleAdvaLinkLossForwarding
INTEGER,
sleAdvaAdminState
INTEGER,
sleAdvaRemoteInterfaceIndex
INTEGER,
sleAdvaUserDefinedString
OCTET STRING,
sleAdvaRemoteSignalling
INTEGER,
sleAdvaConfiguration
INTEGER,
sleAdvaLocalTechnologyAbility
BITS,
sleAdvaAdvertisedTechnologyAbility
BITS,
sleAdvaReceivedTechnologyAbility
BITS,
sleAdvaLocalSectorAbility
BITS,
sleAdvaAdvertisedSectorAbility
BITS,
sleAdvaReceivedSectorAbility
BITS,
sleAdvaDuplexCapabilities
INTEGER,
sleAdvaPHYType
INTEGER,
sleAdvaPHYTypeList
BITS,
sleAdvaMIIDetect
INTEGER,
sleAdvaPHYState
INTEGER,
sleAdvaGoodFramesTransmitted
Integer32,
sleAdvaSingleCollisionFrames
Integer32,
sleAdvaMultipleCollisionFrames
Integer32,
sleAdvaGoodFramesReceived
Integer32,
sleAdvaFCSErrors
Integer32,
sleAdvaAlignmentErrors
Integer32,
sleAdvaFramesTooLong
Integer32,
sleAdvaBytesTransmitted
Integer32,
sleAdvaBytesReceived
Integer32,
sleAdvaSymbolErrors
Integer32
}
sleAdvaRemInstance OBJECT-TYPE
SYNTAX INTEGER (0..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralEntry 1 }
sleAdvaOperationalStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2),
outofservice(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"encoding TBD. (General)"
::= { sleAdvaGeneralEntry 2 }
sleAdvaLineSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line speed in kbit/s. (General)"
::= { sleAdvaGeneralEntry 3 }
sleAdvaMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Ethernet address of the interface. (General)"
::= { sleAdvaGeneralEntry 4 }
sleAdvaConnectorType OBJECT-TYPE
SYNTAX INTEGER
{
sc(1),
fc(2),
mu(3),
rj45(4),
lu(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"encoding TBD. (General)"
::= { sleAdvaGeneralEntry 5 }
sleAdvaAutonegiotation OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegAdminState. (General)Enabled or disabled. "
::= { sleAdvaGeneralEntry 6 }
sleAdvaLinkLossForwarding OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When enabled access interface is brought down, when both network interfaces are down. (General)"
::= { sleAdvaGeneralEntry 7 }
sleAdvaAdminState OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the interface is available. (General)"
::= { sleAdvaGeneralEntry 8 }
sleAdvaRemoteInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the remote interface the interface is connected to. (General)"
::= { sleAdvaGeneralEntry 9 }
sleAdvaUserDefinedString OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User definable string associated with interface. (General)"
::= { sleAdvaGeneralEntry 10 }
sleAdvaRemoteSignalling OBJECT-TYPE
SYNTAX INTEGER
{
detected(1),
notdetected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegRemoteSignalling. (AutoNego)"
::= { sleAdvaGeneralEntry 11 }
sleAdvaConfiguration OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
configuring(2),
completed(3),
disabled(4),
parallelDetectFail(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegConfig.
(AutoNego)Indicates whether Auto-Negotiation
signaling is in progress or has completed."
::= { sleAdvaGeneralEntry 12 }
sleAdvaLocalTechnologyAbility OBJECT-TYPE
SYNTAX BITS
{
global(0),
unknown(1),
base10T(2),
base10TFD(3),
base100T4(4),
base100TX(5),
base100TXFD(6),
fdxpause(7),
fdxapause(8),
fdxspause(9),
fdxbpause(10),
base100T2(11),
base100T2FD(12),
base1000X(13),
base1000XFD(14),
base1000T(15),
base1000TFD(16),
remFault1(17),
remFault2(18),
isoEthernet(19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegLocalTechnologyAbility.
(AutoNego)This indicates the technology ability of the local device"
::= { sleAdvaGeneralEntry 13 }
sleAdvaAdvertisedTechnologyAbility OBJECT-TYPE
SYNTAX BITS
{
global(0),
unknown(1),
base10T(2),
base10TFD(3),
base100T4(4),
base100TX(5),
base100TXFD(6),
fdxpause(7),
fdxapause(8),
fdxspause(9),
fdxbpause(10),
base100T2(11),
base100T2FD(12),
base1000X(13),
base1000XFD(14),
base1000T(15),
base1000TFD(16),
remFault1(17),
remFault2(18),
isoEthernet(19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegAdvertisedTechnologyAbility.
(AutoNego)The advertised technology ability of the local device."
::= { sleAdvaGeneralEntry 14 }
sleAdvaReceivedTechnologyAbility OBJECT-TYPE
SYNTAX BITS
{
global(0),
unknown(1),
base10T(2),
base10TFD(3),
base100T4(4),
base100TX(5),
base100TXFD(6),
fdxpause(7),
fdxapause(8),
fdxspause(9),
fdxbpause(10),
base100T2(11),
base100T2FD(12),
base1000X(13),
base1000XFD(14),
base1000T(15),
base1000TFD(16),
remFault1(17),
remFault2(18),
isoEthernet(19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegReceivedTechnologyAbility.
(AutoNego)Indicates the advertised technology ability of the
remote hardware."
::= { sleAdvaGeneralEntry 15 }
sleAdvaLocalSectorAbility OBJECT-TYPE
SYNTAX BITS
{
other(0),
ethernet(1),
isoethernet(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)"
::= { sleAdvaGeneralEntry 16 }
sleAdvaAdvertisedSectorAbility OBJECT-TYPE
SYNTAX BITS
{
other(0),
ethernet(1),
isoethernet(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)"
::= { sleAdvaGeneralEntry 17 }
sleAdvaReceivedSectorAbility OBJECT-TYPE
SYNTAX BITS
{
other(0),
ethernet(1),
isoethernet(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Autonegiotation package - aAutoNegLocalSectorAbility. (AutoNego)"
::= { sleAdvaGeneralEntry 18 }
sleAdvaDuplexCapabilities OBJECT-TYPE
SYNTAX INTEGER
{
halfduplex(0),
fullduplex(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mandatory package - aMacCapabilities.
(PHY)The modes of duplex the access interface can support"
::= { sleAdvaGeneralEntry 19 }
sleAdvaPHYType OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
unknown(2),
none(3),
base10(4),
base100T4(5),
base100X(6),
base100T2(7),
base1000X(8),
base1000T(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Basic Package - aPhyType. (PHY)"
::= { sleAdvaGeneralEntry 20 }
sleAdvaPHYTypeList OBJECT-TYPE
SYNTAX BITS
{
other(0),
unknown(1),
none(2),
base10(3),
base100T4(4),
base100X(5),
base100T2(6),
base1000X(7),
base1000T(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Basic Package - aPhyTypeList. (PHY)"
::= { sleAdvaGeneralEntry 21 }
sleAdvaMIIDetect OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
nothingConnected(2),
connected(3),
absent(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Basic Package - aMIIDetect. (PHY)"
::= { sleAdvaGeneralEntry 22 }
sleAdvaPHYState OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralEntry 23 }
sleAdvaGoodFramesTransmitted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mandatory package - aFramesTransmittedOK. (PHY)Non-resettable,
wrapping count of good frames transmitted since OAM enabled."
::= { sleAdvaGeneralEntry 24 }
sleAdvaSingleCollisionFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mandatory package - aSingleCollisionFrames. (PHY)Non-resettable,
wrapping count of single collisions since OAM enabled."
::= { sleAdvaGeneralEntry 25 }
sleAdvaMultipleCollisionFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mandatory package - aMultipleCollisionFrames. (PHY)Non-resettable,
wrapping count of multiple collisions since OAM enabled."
::= { sleAdvaGeneralEntry 26 }
sleAdvaGoodFramesReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mandatory package - aFramesReceivedOKNon-resettable,
wrapping count of good frames received since OAM enabled"
::= { sleAdvaGeneralEntry 27 }
sleAdvaFCSErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mandatory package - aFrameCheckSequenceErrors. (PHY)Non-resettable,
wrapping count of frames received with frame check sequence
error since OAM enabled."
::= { sleAdvaGeneralEntry 28 }
sleAdvaAlignmentErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mandatory package - aAlignmentErrors. (PHY)Non-resettable,
wrapping count of frames received with alignment error since OAM enabled."
::= { sleAdvaGeneralEntry 29 }
sleAdvaFramesTooLong OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"aFrameTooLongErrors. (PHY)Non-resettable, wrapping count
of frames received longer than maxFrameSize"
::= { sleAdvaGeneralEntry 30 }
sleAdvaBytesTransmitted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Non-resettable, wrapping count of bytes transmitted
since OAM enabled. (PHY)"
::= { sleAdvaGeneralEntry 31 }
sleAdvaBytesReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Non-resettable, wrapping count of bytes received since OAM enabled. (PHY)"
::= { sleAdvaGeneralEntry 32 }
sleAdvaSymbolErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Non-resettable, wrapping count of symbol errors received.
Note: some interfaces may only report one symbol error per frame. (PHY)"
::= { sleAdvaGeneralEntry 33 }
sleAdvaGeneralControl OBJECT IDENTIFIER ::= { sleAdvaGeneral 2 }
sleAdvaGeneralControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setAdvaGeneralProfile(1),
setAdvaAutonegProfile(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 1 }
sleAdvaGeneralControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 2 }
sleAdvaGeneralControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 3 }
sleAdvaGeneralControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 4 }
sleAdvaGeneralControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 5 }
sleAdvaGeneralControlPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 6 }
sleAdvaGeneralControlRemInstance OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 7 }
sleAdvaGeneralControlLineSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 8 }
sleAdvaGeneralControlAutonegiotation OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 9 }
sleAdvaGeneralControlLinkLossForwarding OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 10 }
sleAdvaGeneralControlUserDefinedString OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 11 }
sleAdvaGeneralControlAdvertisedTechnologyAbility OBJECT-TYPE
SYNTAX BITS
{
global(0),
unknown(1),
base10T(2),
base10TFD(3),
base100T4(4),
base100TX(5),
base100TXFD(6),
fdxpause(7),
fdxapause(8),
fdxspause(9),
fdxbpause(10),
base100T2(11),
base100T2FD(12),
base1000X(13),
base1000XFD(14),
base1000T(15),
base1000TFD(16),
remFault1(17),
remFault2(18),
isoEthernet(19)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 12 }
sleAdvaGeneralControlAdvertisedSectorAbility OBJECT-TYPE
SYNTAX BITS
{
other(0),
ethernet(1),
isoethernet(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralControl 13 }
sleAdvaGeneralNotification OBJECT IDENTIFIER ::= { sleAdvaGeneral 3 }
sleAdvaGeneralProfileChanged NOTIFICATION-TYPE
OBJECTS { sleAdvaGeneralControlRequest, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlTimeStamp, sleAdvaLineSpeed, sleAdvaAutonegiotation,
sleAdvaLinkLossForwarding, sleAdvaUserDefinedString }
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralNotification 1 }
sleAdvaAutonegProfileChanged NOTIFICATION-TYPE
OBJECTS { sleAdvaGeneralControlRequest, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlTimeStamp, sleAdvaAdvertisedTechnologyAbility, sleAdvaAdvertisedSectorAbility
}
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaGeneralNotification 2 }
sleAdvaModule OBJECT IDENTIFIER ::= { sleFaultMgmt 8 }
sleAdvaModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAdvaModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaModule 1 }
sleAdvaModuleEntry OBJECT-TYPE
SYNTAX SleAdvaModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleOamPortIndex, sleAdvaRemInstance }
::= { sleAdvaModuleTable 1 }
SleAdvaModuleEntry ::=
SEQUENCE {
sleAdvaModuleType
INTEGER,
sleAdvaModulePartNumber
OCTET STRING,
sleAdvaModuleSerialNumber
OCTET STRING,
sleAdvaModuleFirmwareVersion
OCTET STRING,
sleAdvaModuleSoftwareVersion
OCTET STRING,
sleAdvaModuleHardwareRevision
OCTET STRING,
sleAdvaModuleCLEICode
OCTET STRING
}
sleAdvaModuleType OBJECT-TYPE
SYNTAX INTEGER
{
sfp(1),
nemi(2),
other(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"encoding TBD"
::= { sleAdvaModuleEntry 1 }
sleAdvaModulePartNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Part number for the module"
::= { sleAdvaModuleEntry 2 }
sleAdvaModuleSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number for the module"
::= { sleAdvaModuleEntry 3 }
sleAdvaModuleFirmwareVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Firmware version for the module."
::= { sleAdvaModuleEntry 4 }
sleAdvaModuleSoftwareVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software version for the module"
::= { sleAdvaModuleEntry 5 }
sleAdvaModuleHardwareRevision OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware revision for the module."
::= { sleAdvaModuleEntry 6 }
sleAdvaModuleCLEICode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..14))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CLEI for the module."
::= { sleAdvaModuleEntry 7 }
sleAdvaOptical OBJECT IDENTIFIER ::= { sleFaultMgmt 9 }
sleAdvaOpticalTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAdvaOpticalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOptical 1 }
sleAdvaOpticalEntry OBJECT-TYPE
SYNTAX SleAdvaOpticalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleOamPortIndex, sleAdvaRemInstance }
::= { sleAdvaOpticalTable 1 }
SleAdvaOpticalEntry ::=
SEQUENCE {
sleAdvaOpticalThresholdLevel
INTEGER,
sleAdvaLinkLength1
INTEGER,
sleAdvaLinkLength2
INTEGER,
sleAdvaLinkLength3
INTEGER,
sleAdvaLinkLength4
INTEGER,
sleAdvaLinkLengthCu
INTEGER,
sleAdvaWaveLength
INTEGER,
sleAdvaLaserBias
INTEGER,
sleAdvaTransmitPower
INTEGER,
sleAdvaReceivePower
INTEGER,
sleAdvaLaserTxTemperature
INTEGER
}
sleAdvaOpticalThresholdLevel OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Threshold for the receive power level in dBm below which
the Interface optical threshold alarm will be activated.Per interface."
::= { sleAdvaOpticalEntry 1 }
sleAdvaLinkLength1 OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link length supported for 9/125 mm fiber, units of km"
::= { sleAdvaOpticalEntry 2 }
sleAdvaLinkLength2 OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link length supported for 9/125 mm fiber, units of 100 m"
::= { sleAdvaOpticalEntry 3 }
sleAdvaLinkLength3 OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link length supported for 50/125 mm fiber, units of 10 m"
::= { sleAdvaOpticalEntry 4 }
sleAdvaLinkLength4 OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link length supported for 62.5/125 mm fiber, units of 10 m"
::= { sleAdvaOpticalEntry 5 }
sleAdvaLinkLengthCu OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link length supported for copper, units of meters"
::= { sleAdvaOpticalEntry 6 }
sleAdvaWaveLength OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal wavelength in nm"
::= { sleAdvaOpticalEntry 7 }
sleAdvaLaserBias OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current laser bias current in mA."
::= { sleAdvaOpticalEntry 8 }
sleAdvaTransmitPower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit power in dBm as reported by optics."
::= { sleAdvaOpticalEntry 9 }
sleAdvaReceivePower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive power in dBm as reported by optics. "
::= { sleAdvaOpticalEntry 10 }
sleAdvaLaserTxTemperature OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current temperature of laser in degrees C."
::= { sleAdvaOpticalEntry 11 }
sleAdvaOpticalControl OBJECT IDENTIFIER ::= { sleAdvaOptical 2 }
sleAdvaOpticalControlRequest OBJECT-TYPE
SYNTAX INTEGER { setAdvaOpticalAlarm(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 1 }
sleAdvaOpticalControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 2 }
sleAdvaOpticalControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 3 }
sleAdvaOpticalControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 4 }
sleAdvaOpticalControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 5 }
sleAdvaOpticalControlPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 6 }
sleAdvaOpticalControlRemInstance OBJECT-TYPE
SYNTAX INTEGER (1..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 7 }
sleAdvaOpticalControlThresholdLevel OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalControl 8 }
sleAdvaOpticalNotification OBJECT IDENTIFIER ::= { sleAdvaOptical 3 }
sleAdvaOpticalAlarmChanged NOTIFICATION-TYPE
OBJECTS { sleAdvaOpticalControlRequest, sleAdvaOpticalControlReqResult, sleAdvaOpticalControlTimeStamp, sleAdvaOpticalThresholdLevel }
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOpticalNotification 1 }
sleAdvaOam OBJECT IDENTIFIER ::= { sleFaultMgmt 10 }
sleAdvaOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAdvaOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOam 1 }
sleAdvaOamEntry OBJECT-TYPE
SYNTAX SleAdvaOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleOamPortIndex, sleAdvaRemInstance }
::= { sleAdvaOamTable 1 }
SleAdvaOamEntry ::=
SEQUENCE {
sleAdvaAdminStatus
INTEGER,
sleAdvaMode
INTEGER,
sleAdvaRemMACAddress
OCTET STRING,
sleAdvaRemConfig
BITS,
sleAdvaRemPduConfig
INTEGER,
sleAdvaLocFlags
BITS,
sleAdvaRemFlags
BITS,
sleAdvaRemState
BITS,
sleAdvaRemVendorOUI
INTEGER,
sleAdvaRemDeviceNumber
INTEGER,
sleAdvaRemVendorVersion
INTEGER,
sleAdvaLocErrSymbolPeriodEventConfig
INTEGER,
sleAdvaLocErrFrameEventConfig
INTEGER,
sleAdvaLocErrFramePeriodEventConfig
INTEGER,
sleAdvaLocErrFrameSecsSummaryEventConfig
INTEGER,
sleAdvaPDUsTx
Integer32,
sleAdvaPDUsRx
Integer32,
sleAdvaUnsupportedCodesRx
Integer32,
sleAdvaInfoPDUsTx
Integer32,
sleAdvaInfoPDUsRx
Integer32,
sleAdvaEventNotificationPDUsTx
Integer32,
sleAdvaUniqueEventNotificationPDUsTx
Integer32,
sleAdvaDupEventNotificationPDUsTx
Integer32,
sleAdvaLoopbackControlPDUsTx
Integer32,
sleAdvaLoopbackControlPDUsRx
Integer32,
sleAdvaVariableRequestPDUsTx
Integer32,
sleAdvaVariableRequestPDUsRx
Integer32,
sleAdvaVariableResponsePDUsTx
Integer32,
sleAdvaVariableResponsePDUsRx
Integer32,
sleAdvaVendorPDUsTx
Integer32,
sleAdvaVendorPDUsRx
Integer32,
sleAdvaRemFramesLostDuetoOAMErr
Integer32,
sleAdvaLocErrSymbolPeriodEvent
Integer32,
sleAdvaLocErrFrameSecsEvent
Integer32,
sleAdvaLocErrFramePeriodEvent
Integer32,
sleAdvaLocErrFrameSecsSummaryEvent
Integer32,
sleAdvaRemErrSymbolPeriodEvent
Integer32,
sleAdvaRemErrFrameSecsEvent
Integer32,
sleAdvaRemoteErrorFramePeriodEvent
Integer32,
sleAdvaRemoteErrorFrameSecsSummaryEvent
Integer32
}
sleAdvaAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMAdminState (Configuration)Whether
the OAM sublayer is enabled or disabled."
::= { sleAdvaOamEntry 1 }
sleAdvaMode OBJECT-TYPE
SYNTAX INTEGER
{
passive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMMode. (Configuration)Mode of the OAM client"
::= { sleAdvaOamEntry 2 }
sleAdvaRemMACAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemoteMACAddress. (Configuration)"
::= { sleAdvaOamEntry 3 }
sleAdvaRemConfig OBJECT-TYPE
SYNTAX BITS
{
unidirSupport(0),
loopbackSupport(1),
linkEvents(2),
variableRetrieval(3),
orgSpecific(4),
orgSpecificEvents(5),
orgSpecificInfoTLV(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemoteConfiguration. (Configuration)Bit-mask
corresponding to the OAM configuration field:"
::= { sleAdvaOamEntry 4 }
sleAdvaRemPduConfig OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemotePDUConfiguration. (Configuration)The maximum
PDU size supported"
::= { sleAdvaOamEntry 5 }
sleAdvaLocFlags OBJECT-TYPE
SYNTAX BITS
{
linkFault(0),
dyingGasp(1),
criticalEvent(2),
localStableDiscovering(3),
localStable(4),
remoteStableDiscovering(5),
remoteStable(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMLocalFlags. (Configuration)Bit-mask corresponding
to the OAM flag field transmitted:"
::= { sleAdvaOamEntry 6 }
sleAdvaRemFlags OBJECT-TYPE
SYNTAX BITS
{
linkFault(0),
dyingGasp(1),
criticalEvent(2),
localStableDiscovering(3),
localStable(4),
remoteStableDiscovering(5),
remoteStable(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemoteFlags. (Configuration)Bit-mask corresponding
to the OAM flag field received"
::= { sleAdvaOamEntry 7 }
sleAdvaRemState OBJECT-TYPE
SYNTAX BITS
{
reserved(0),
parserAction1(1),
parserAction2(2),
muxAction(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemoteState. (Configuration)Bit-mask corresponding
to the OAM State field received"
::= { sleAdvaOamEntry 8 }
sleAdvaRemVendorOUI OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemoteVendorOUI. (Configuration)The value of
the OUI from the remote end of the OAM link."
::= { sleAdvaOamEntry 9 }
sleAdvaRemDeviceNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemoteVendorIdDeviceNumber. (Configuration)
The value of the Device Identifier from the remote end of the OAM link."
::= { sleAdvaOamEntry 10 }
sleAdvaRemVendorVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMRemoteVendorIdVersion. (Configuration)
The value of the Version Identifier from the remote end of the OAM link."
::= { sleAdvaOamEntry 11 }
sleAdvaLocErrSymbolPeriodEventConfig OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMLocalErrSymPeriodConfig. (Configuration)
Configuration for the event indicating the duration of
the period and the number of symbols that must be exceeded."
::= { sleAdvaOamEntry 12 }
sleAdvaLocErrFrameEventConfig OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMLocalErrFrameConfig. (Configuration)
Configuration for the event indicating the duration and
the number of errored frames that must be exceeded."
::= { sleAdvaOamEntry 13 }
sleAdvaLocErrFramePeriodEventConfig OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMLocalErrFramePeriodConfig. (Configuration)
Configuration for the event indicating the durationin terms of
minFrameSize that can be transmitted and that number of errored
frames that must be exceeded."
::= { sleAdvaOamEntry 14 }
sleAdvaLocErrFrameSecsSummaryEventConfig OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMLocalErrFrameSecsSummaryConfig. (Configuration)
Configuration for the evert indicating duration window and number
of errored frame seconds in that duration that must be exceeded."
::= { sleAdvaOamEntry 15 }
sleAdvaPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMPDUTx. (PDU Performance)Non-resettable,
wrapping count of OAM PDUs transmitted since OAM enabled."
::= { sleAdvaOamEntry 16 }
sleAdvaPDUsRx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMPDURx. (PDU Performance)Non-resettable,
wrapping count of OAM PDUs received since OAM enabled."
::= { sleAdvaOamEntry 17 }
sleAdvaUnsupportedCodesRx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMUnsupportedCodesRx. (PDU Performance)Non-resettable,
wrapping count of OAM PDUs received that are not supported by device
since OAM enabled."
::= { sleAdvaOamEntry 18 }
sleAdvaInfoPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMInformationTx. (PDU Performance)Non-resettable,
wrapping count of OAM Info PDUs transmitted since OAM enabled."
::= { sleAdvaOamEntry 19 }
sleAdvaInfoPDUsRx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMInformationRx. (PDU Performance)Non-resettable,
wrapping count of OAM Info PDUs received since OAM enabled."
::= { sleAdvaOamEntry 20 }
sleAdvaEventNotificationPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMEventNotificationTx. (PDU Performance)Non-resettable,
wrapping count of OAM Event PDUs transmitted since OAM enabled."
::= { sleAdvaOamEntry 21 }
sleAdvaUniqueEventNotificationPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMUniqueEventNotificationTx. (PDU Performance)
Non-resettable, wrapping count of OAM Event PDUs received with
a different sequence number than previously since OAM enabled."
::= { sleAdvaOamEntry 22 }
sleAdvaDupEventNotificationPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMDuplicateEventNotificationTx. (PDU Performance)
Non-resettable, wrapping count of OAM Event PDUs received with the
same sequence number as previously since OAM enabled."
::= { sleAdvaOamEntry 23 }
sleAdvaLoopbackControlPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMLoopbackControlTx. (PDU Performance)
Non-resettable, wrapping count of OAM Loopback Control PDUs
transmitted since OAM enabled."
::= { sleAdvaOamEntry 24 }
sleAdvaLoopbackControlPDUsRx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMLoopbackControlRx. (PDU Performance)
Non-resettable, wrapping count of OAM Loopback Control PDUs
received since OAM enabled."
::= { sleAdvaOamEntry 25 }
sleAdvaVariableRequestPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMVariableRequestTx. (PDU Performance)
Non-resettable, wrapping count of OAM Variable Request PDUs
transmitted since OAM enabled."
::= { sleAdvaOamEntry 26 }
sleAdvaVariableRequestPDUsRx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMVariableRequestRx. (PDU Performance)
Non-resettable, wrapping count of OAM Variable Request PDUs
received since OAM enabled."
::= { sleAdvaOamEntry 27 }
sleAdvaVariableResponsePDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMVariableResponseTx. (PDU Performance)
Non-resettable, wrapping count of OAM Variable Response PDUs
transmitted since OAM enabled."
::= { sleAdvaOamEntry 28 }
sleAdvaVariableResponsePDUsRx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMVariableResponseRx. (PDU Performance)
Non-resettable, wrapping count of OAM Variable Response PDUs
received since OAM enabled"
::= { sleAdvaOamEntry 29 }
sleAdvaVendorPDUsTx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMOrganizationSpecificTx . (PDU Performance)
Non-resettable, wrapping count of OAM Vendor PDUs transmitted
since OAM enabled."
::= { sleAdvaOamEntry 30 }
sleAdvaVendorPDUsRx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aOAMOrganizationSpecificRx. (PDU Performance)"
::= { sleAdvaOamEntry 31 }
sleAdvaRemFramesLostDuetoOAMErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM package - aFramesLostDueToOAMError. (PDU Performance)
Non-resettable, wrapping count of frames that would have been
transmitted but for an OAM sublayer error."
::= { sleAdvaOamEntry 32 }
sleAdvaLocErrSymbolPeriodEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently transmitted event of this type. (Error)"
::= { sleAdvaOamEntry 33 }
sleAdvaLocErrFrameSecsEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently transmitted event of this type. (Error)"
::= { sleAdvaOamEntry 34 }
sleAdvaLocErrFramePeriodEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently transmitted event of this type. (Error)"
::= { sleAdvaOamEntry 35 }
sleAdvaLocErrFrameSecsSummaryEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently transmitted event of this type. (Error)"
::= { sleAdvaOamEntry 36 }
sleAdvaRemErrSymbolPeriodEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently received event of this type. (Error)"
::= { sleAdvaOamEntry 37 }
sleAdvaRemErrFrameSecsEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently received event of this type. (Error)"
::= { sleAdvaOamEntry 38 }
sleAdvaRemoteErrorFramePeriodEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently received event of this type. (Error)"
::= { sleAdvaOamEntry 39 }
sleAdvaRemoteErrorFrameSecsSummaryEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recently received event of this type. (Error)"
::= { sleAdvaOamEntry 40 }
sleAdvaOamControl OBJECT IDENTIFIER ::= { sleAdvaOam 2 }
sleAdvaOamControlRequest OBJECT-TYPE
SYNTAX INTEGER { setAdvaOamProfile(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 1 }
sleAdvaOamControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 2 }
sleAdvaOamControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 3 }
sleAdvaOamControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 4 }
sleAdvaOamControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 5 }
sleAdvaOamControlPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 6 }
sleAdvaOamControlRemInstance OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 7 }
sleAdvaOamControlAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 8 }
sleAdvaOamControlMode OBJECT-TYPE
SYNTAX INTEGER
{
passive(0),
active(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamControl 9 }
sleAdvaOamNotification OBJECT IDENTIFIER ::= { sleAdvaOam 3 }
setAdvaOamProfileChanged NOTIFICATION-TYPE
OBJECTS { sleAdvaOamControlRequest, sleAdvaOamControlReqResult, sleAdvaOamControlTimeStamp, sleAdvaAdminStatus, sleAdvaMode
}
STATUS current
DESCRIPTION
"Description."
::= { sleAdvaOamNotification 1 }
sleAlarmLED OBJECT IDENTIFIER ::= { sleFaultMgmt 11 }
sleAlarmLEDTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAlarmLEDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLED 1 }
sleAlarmLEDEntry OBJECT-TYPE
SYNTAX SleAlarmLEDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleAlarmLEDType }
::= { sleAlarmLEDTable 1 }
SleAlarmLEDEntry ::=
SEQUENCE {
sleAlarmLEDType
INTEGER,
sleAlarmLEDStatus
INTEGER,
sleAlarmLEDLevel
INTEGER
}
sleAlarmLEDType OBJECT-TYPE
SYNTAX INTEGER
{
fanFail(1),
fanRemove(2),
memoryOver(3),
moduleRemove(4),
portLinkDown(5),
portRemove(6),
portThreadOver(7),
powerFail(8),
powerRemove(9),
temperatureHigh(10),
slotRemove(11),
ponLOS(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm that LED indicate."
::= { sleAlarmLEDEntry 1 }
sleAlarmLEDStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2),
unknown(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of alarm LED."
::= { sleAlarmLEDEntry 2 }
sleAlarmLEDLevel OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
unrated(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Level of alarm LED."
::= { sleAlarmLEDEntry 3 }
sleAlarmLEDLevelTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleAlarmLEDLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLED 2 }
sleAlarmLEDLevelEntry OBJECT-TYPE
SYNTAX SleAlarmLEDLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleAlarmLEDLevelIndex }
::= { sleAlarmLEDLevelTable 1 }
SleAlarmLEDLevelEntry ::=
SEQUENCE {
sleAlarmLEDLevelIndex
INTEGER,
sleAlarmLEDLevelBlock
INTEGER,
sleAlarmLEDLevelOperStatus
INTEGER
}
sleAlarmLEDLevelIndex OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
error(4),
unrated(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LED level index."
::= { sleAlarmLEDLevelEntry 1 }
sleAlarmLEDLevelBlock OBJECT-TYPE
SYNTAX INTEGER
{
unblock(1),
block(2),
unknown(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LED level block."
::= { sleAlarmLEDLevelEntry 2 }
sleAlarmLEDLevelOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm current operation status."
::= { sleAlarmLEDLevelEntry 3 }
sleAlarmLEDControl OBJECT IDENTIFIER ::= { sleAlarmLED 3 }
sleAlarmLEDControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
alarmLedOff(1),
setAlarmLedLevel(2),
clearAlarmLed(3),
alarmLedBlock(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDControl 1 }
sleAlarmLEDControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDControl 2 }
sleAlarmLEDControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDControl 3 }
sleAlarmLEDControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDControl 4 }
sleAlarmLEDControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDControl 5 }
sleAlarmLEDControlType OBJECT-TYPE
SYNTAX INTEGER
{
fanFail(1),
fanRemove(2),
memoryOver(3),
moduleRemove(4),
portLinkDown(5),
portRemove(6),
portThreadOver(7),
powerFail(8),
powerRemove(9),
temperatureHigh(10),
slotRemove(11),
ponLOS(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alarm that LED indicate."
::= { sleAlarmLEDControl 6 }
sleAlarmLEDControlLevel OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
all(254)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Level of alarm LED."
::= { sleAlarmLEDControl 7 }
sleAlarmLEDControlBlock OBJECT-TYPE
SYNTAX INTEGER
{
unblock(1),
block(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LED level block."
::= { sleAlarmLEDControl 8 }
sleAlarmLEDNotification OBJECT IDENTIFIER ::= { sleAlarmLED 4 }
sleAlarmLEDOffChanged NOTIFICATION-TYPE
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlLevel }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDNotification 1 }
sleAlarmLEDLevelChanged NOTIFICATION-TYPE
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType, sleAlarmLEDControlLevel
}
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDNotification 2 }
sleAlarmLEDCleared NOTIFICATION-TYPE
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType }
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDNotification 3 }
sleAlarmLEDBlockChanged NOTIFICATION-TYPE
OBJECTS { sleAlarmLEDControlRequest, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlLevel, sleAlarmLEDControlBlock
}
STATUS current
DESCRIPTION
"Description."
::= { sleAlarmLEDNotification 4 }
sleY1731Oam OBJECT IDENTIFIER ::= { sleFaultMgmt 12 }
sleY1731Base OBJECT IDENTIFIER ::= { sleY1731Oam 1 }
sleY1731BaseGroup OBJECT IDENTIFIER ::= { sleY1731Base 1 }
sleY1731Enable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Ddisables ITU-T Y.1731 OAM function"
::= { sleY1731BaseGroup 1 }
sleY1731TrunkEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables Y.1731 OAM on a trunk port"
::= { sleY1731BaseGroup 2 }
sleY1731LtrCacheHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time that cache entries will be retained"
::= { sleY1731BaseGroup 3 }
sleY1731LtrCacheSize OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of entries in the traceroute cache"
::= { sleY1731BaseGroup 4 }
sleY1731SnmpServerTraps OBJECT-TYPE
SYNTAX BITS
{
rdi(0),
loc(1),
unp(2),
unm(3),
mmg(4),
unl(5),
ais(6),
lck(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the SNMP traps"
::= { sleY1731BaseGroup 5 }
sleY1731XcheckStartDelay OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the delay before the cross-check is started"
::= { sleY1731BaseGroup 6 }
sleY1731DefaultMegLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the level to be created dynamic MHF"
::= { sleY1731BaseGroup 7 }
sleY1731DefaultMegMhfCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
default(1),
explicit(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the mode of MHF creation"
::= { sleY1731BaseGroup 8 }
sleY1731PduToCfm OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables changing from Y.1731 PDU format to CFM PDU format"
::= { sleY1731BaseGroup 9 }
sleY1731DedicatedVlan OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731BaseGroup 10 }
sleY1731RmepCreation OBJECT-TYPE
SYNTAX INTEGER
{
dynamic(1),
static(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RMEP creation mode"
::= { sleY1731BaseGroup 11 }
sleY1731CCIgnoreDefect OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CC Ignore Defect Mode"
::= { sleY1731BaseGroup 12 }
sleY1731RapsFloodingBlock OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"R-APS Flooding Block Mode"
::= { sleY1731BaseGroup 13 }
sleY1731TlvPermission OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
chassis(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates TLV Permission"
::= { sleY1731BaseGroup 14 }
sleY1731BaseControl OBJECT IDENTIFIER ::= { sleY1731Base 2 }
sleY1731BaseControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setY1731Enable(1),
setY1731TrunkEnable(2),
setY1731LtrCacheProfile(3),
setY1731SnmpProfile(4),
setY1731XcheckProfile(5),
setY1731DefaultMegProfile(6),
setY1731PduToCfm(7),
setY1731DedicatedVlan(8),
destroyMipCcdb(9),
destroyLtrCache(10),
setRmepCreation(11),
setTrunkOamstatus(12),
setY1731CCIgnoreDefect(13),
setY1731RapsFloodingBlock(14),
setY1731TlvPermission(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This attribute identifies the control commands.
updateAlarmList:
the NE updates entries of alarms in the sleAlarmListTable
after having changed alarm severities of alarms
(due to change profile pointers in
managed entities or after modification of alarm severities
in profiles). This command should be applied once after having
finisled modifications of severties.
modifyAlarmSeverity:
modifies the severity of an alarm in specific profile.
createAlarmSeverityProfile:
creates a new profile with default severities.
The severities then have to be modified with command changeAlarmSeverity.
deleteAlarmSeverityProfile:
deletes a profile. Profile 1 is not allowed to be deleted.
Notifications : none "
::= { sleY1731BaseControl 1 }
sleY1731BaseControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleY1731BaseControl 2 }
sleY1731BaseControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleY1731BaseControl 3 }
sleY1731BaseControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleY1731BaseControl 4 }
sleY1731BaseControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleY1731BaseControl 5 }
sleY1731BaseControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Ddisables ITU-T Y.1731 OAM function"
::= { sleY1731BaseControl 6 }
sleY1731BaseControlTrunkEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables Y.1731 OAM on a trunk port"
::= { sleY1731BaseControl 7 }
sleY1731BaseControlLtrCacheHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the time that cache entries will be retained"
::= { sleY1731BaseControl 8 }
sleY1731BaseControlLtrCacheSize OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the number of entries in the traceroute cache"
::= { sleY1731BaseControl 9 }
sleY1731BaseControlSnmpServerTraps OBJECT-TYPE
SYNTAX BITS
{
rdi(0),
loc(1),
unp(2),
unm(3),
mmg(4),
unl(5),
ais(6),
lck(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the SNMP traps"
::= { sleY1731BaseControl 10 }
sleY1731BaseControlXcheckStartDelay OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the delay before the cross-check is started"
::= { sleY1731BaseControl 11 }
sleY1731BaseControlDefaultMegLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the level to be created dynamic MHF"
::= { sleY1731BaseControl 12 }
sleY1731BaseControlDefaultMegMhfCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
default(1),
explicit(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the mode of MHF creation"
::= { sleY1731BaseControl 13 }
sleY1731BaseControlPduToCfm OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731BaseControl 14 }
sleY1731BaseControlDedicatedVlan OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731BaseControl 15 }
sleY1731BaseControlRmepCreation OBJECT-TYPE
SYNTAX INTEGER
{
dynamic(1),
static(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RMEP creation mode"
::= { sleY1731BaseControl 16 }
sleY1731BaseControlTrunkIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk Index"
::= { sleY1731BaseControl 17 }
sleY1731BaseControlTrunkOamStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM status per each Trunk port."
::= { sleY1731BaseControl 18 }
sleY1731BaseControlTrunkMeg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"trunk port meg name."
::= { sleY1731BaseControl 19 }
sleY1731BaseControlCCIgnoreDefect OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CC Ignore Defect Mode"
::= { sleY1731BaseControl 20 }
sleY1731BaseControlRapsFloodingBlock OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"R-APS Flooding Block Mode"
::= { sleY1731BaseControl 21 }
sleY1731BaseControlTlvPermission OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
chassis(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates TLV Permission"
::= { sleY1731BaseControl 22 }
sleY1731BaseNotification OBJECT IDENTIFIER ::= { sleY1731Base 3 }
sleY1731EnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlEnable }
STATUS current
DESCRIPTION
"setY1731Enable"
::= { sleY1731BaseNotification 1 }
sleY1731TrunkEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTrunkEnable }
STATUS current
DESCRIPTION
"setY1731TrunkEnable"
::= { sleY1731BaseNotification 2 }
sleY1731LtrCacheProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlLtrCacheHoldTime, sleY1731BaseControlLtrCacheSize
}
STATUS current
DESCRIPTION
"setY1731LtrCacheProfile"
::= { sleY1731BaseNotification 3 }
sleY1731SnmpProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlSnmpServerTraps }
STATUS current
DESCRIPTION
"setY1731SnmpProfile"
::= { sleY1731BaseNotification 4 }
sleY1731XcheckProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlXcheckStartDelay }
STATUS current
DESCRIPTION
"setY1731XcheckProfile"
::= { sleY1731BaseNotification 5 }
sleY1731DefaultMegProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlDefaultMegLevel, sleY1731BaseControlDefaultMegMhfCreation
}
STATUS current
DESCRIPTION
"setY1731DefaultMegProfile"
::= { sleY1731BaseNotification 6 }
sleY1731PduToCfmChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlPduToCfm }
STATUS current
DESCRIPTION
"Description."
::= { sleY1731BaseNotification 7 }
sleY1731DedicatedVlanChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlDedicatedVlan }
STATUS current
DESCRIPTION
"Description."
::= { sleY1731BaseNotification 8 }
sleY1731MipCcdbDestroyed NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult }
STATUS current
DESCRIPTION
"destroyMipCcdb"
::= { sleY1731BaseNotification 9 }
sleY1731LtrCacheDestroyed NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult }
STATUS current
DESCRIPTION
"destroyLtrCache"
::= { sleY1731BaseNotification 10 }
sleY1731RmepCreationChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlRmepCreation }
STATUS current
DESCRIPTION
"sleY1731BaseControlRmepCreation"
::= { sleY1731BaseNotification 11 }
sleY1731TrunkOamStatusChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTrunkIndex, sleY1731BaseControlTrunkOamStatus,
sleY1731BaseControlTrunkMeg }
STATUS current
DESCRIPTION
"sleY1731BaseControlTrunkIndex
sleY1731BaseControlTrunkOamStatus"
::= { sleY1731BaseNotification 12 }
sleY1731CCIgnoreDefectChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlCCIgnoreDefect }
STATUS current
DESCRIPTION
"sleY1731BaseControlCCIgnoreDefect"
::= { sleY1731BaseNotification 13 }
sleY1731RapsFloodinBlockChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlRapsFloodingBlock }
STATUS current
DESCRIPTION
"sleY1731BaseControlCCIgnoreDefect"
::= { sleY1731BaseNotification 14 }
sleY1731TlvPermissionChanged NOTIFICATION-TYPE
OBJECTS { sleY1731BaseControlRequest, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlTlvPermission }
STATUS current
DESCRIPTION
"setY1731TlvPermission"
::= { sleY1731BaseNotification 15 }
sleY1731TrunkTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731TrunkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731Base 4 }
sleY1731TrunkEntry OBJECT-TYPE
SYNTAX SleY1731TrunkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731TrunkIndex }
::= { sleY1731TrunkTable 1 }
SleY1731TrunkEntry ::=
SEQUENCE {
sleY1731TrunkIndex
INTEGER,
sleY1731TrunkOamStatus
INTEGER,
sleY1731TrunkMeg
OCTET STRING
}
sleY1731TrunkIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"trunk port index."
::= { sleY1731TrunkEntry 1 }
sleY1731TrunkOamStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OAM status per each Trunk port."
::= { sleY1731TrunkEntry 2 }
sleY1731TrunkMeg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"trunk port meg name."
::= { sleY1731TrunkEntry 3 }
sleY1731Meg OBJECT IDENTIFIER ::= { sleY1731Oam 2 }
sleY1731MegTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731MegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731Meg 1 }
sleY1731MegEntry OBJECT-TYPE
SYNTAX SleY1731MegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex }
::= { sleY1731MegTable 1 }
SleY1731MegEntry ::=
SEQUENCE {
sleY1731MegIndex
Integer32,
sleY1731MegName
OCTET STRING,
sleY1731MegLevel
Integer32,
sleY1731MegVid
Integer32,
sleY1731MegMepEnable
INTEGER,
sleY1731MegCcEnable
INTEGER,
sleY1731MegCcInterval
Integer32,
sleY1731MegCcPriority
Integer32,
sleY1731MegCcLossThreshold
Integer32,
sleY1731MegCcHoldTime
Integer32,
sleY1731MegFaultPriority
Integer32,
sleY1731MegFaultKeepTime
Integer32,
sleY1731MegFaultClearTime
Integer32,
sleY1731MegXcheckEnable
INTEGER,
sleY1731MegAisEnable
INTEGER,
sleY1731MegAisTransmitEnable
INTEGER,
sleY1731MegAisInterval
INTEGER,
sleY1731MegAisLevel
Integer32,
sleY1731MegAisPriority
Integer32,
sleY1731MegLckEnable
INTEGER,
sleY1731MegLckTransmitEnable
INTEGER,
sleY1731MegLckInterval
INTEGER,
sleY1731MegLckLevel
Integer32,
sleY1731MegLckPriority
Integer32,
sleY1731MegOutOfService
INTEGER,
sleY1731MegRapsEnable
INTEGER,
sleY1731MegRapsRplOwner
INTEGER,
sleY1731MegRapsEastPort
Integer32,
sleY1731MegRapsWestPort
Integer32,
sleY1731MegRapsRplPort
INTEGER,
sleY1731MegRapsHoldOffTime
Integer32,
sleY1731MegRapsGuardTime
Integer32,
sleY1731MegRapsWaitToRestore
Integer32,
sleY1731MegRapsState
INTEGER,
sleY1731MegRapsEastPortStatus
INTEGER,
sleY1731MegRapsWestPortStatus
INTEGER,
sleY1731MegRapsNonRevertive
INTEGER,
sleY1731MegRapsForcedSwitchEast
INTEGER,
sleY1731MegRapsForcedSwitchWest
INTEGER,
sleY1731MegMd
OCTET STRING
}
sleY1731MegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MEG's Index"
::= { sleY1731MegEntry 1 }
sleY1731MegName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MEG's name: ICC (6 bytes) + UMC (6 bytes)"
::= { sleY1731MegEntry 2 }
sleY1731MegLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MEG's level"
::= { sleY1731MegEntry 3 }
sleY1731MegVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MEG's VID"
::= { sleY1731MegEntry 4 }
sleY1731MegMepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables Y.1731 OAM for MEPs"
::= { sleY1731MegEntry 5 }
sleY1731MegCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables MEPs to send Continuity Check messages"
::= { sleY1731MegEntry 6 }
sleY1731MegCcInterval OBJECT-TYPE
SYNTAX Integer32 (1 | 2..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interval between CCM transmissions"
::= { sleY1731MegEntry 7 }
sleY1731MegCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the CCM or LTM Message Priority"
::= { sleY1731MegEntry 8 }
sleY1731MegCcLossThreshold OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
::= { sleY1731MegEntry 9 }
sleY1731MegCcHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time that data of a missing MEP is kept"
::= { sleY1731MegEntry 10 }
sleY1731MegFaultPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the lowest priority for fault alarm"
::= { sleY1731MegEntry 11 }
sleY1731MegFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the keep time for the fault alarm"
::= { sleY1731MegEntry 12 }
sleY1731MegFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the clear time for the fault alarm"
::= { sleY1731MegEntry 13 }
sleY1731MegXcheckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables Y.1731 cross-check for a specific MEG"
::= { sleY1731MegEntry 14 }
sleY1731MegAisEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables ETH-AIS function"
::= { sleY1731MegEntry 15 }
sleY1731MegAisTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables ETH-AIS frame transmission on a MEP"
::= { sleY1731MegEntry 16 }
sleY1731MegAisInterval OBJECT-TYPE
SYNTAX INTEGER
{
oneSecond(4),
oneMinute(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interval between AIS transmissions"
::= { sleY1731MegEntry 17 }
sleY1731MegAisLevel OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the client MEG's level"
::= { sleY1731MegEntry 18 }
sleY1731MegAisPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the AIS Message Priority"
::= { sleY1731MegEntry 19 }
sleY1731MegLckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables ETH-LCK function"
::= { sleY1731MegEntry 20 }
sleY1731MegLckTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables ETH-LCK frame transmission on a MEP"
::= { sleY1731MegEntry 21 }
sleY1731MegLckInterval OBJECT-TYPE
SYNTAX INTEGER
{
oneSecond(4),
oneMinute(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interval between LCK transmissions"
::= { sleY1731MegEntry 22 }
sleY1731MegLckLevel OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the client MEG's level"
::= { sleY1731MegEntry 23 }
sleY1731MegLckPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the LCK Message Priority"
::= { sleY1731MegEntry 24 }
sleY1731MegOutOfService OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the out-of-service mode"
::= { sleY1731MegEntry 25 }
sleY1731MegRapsEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables R-APS node"
::= { sleY1731MegEntry 26 }
sleY1731MegRapsRplOwner OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the owner of the ring protection link"
::= { sleY1731MegEntry 27 }
sleY1731MegRapsEastPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the east port of R-APS node"
::= { sleY1731MegEntry 28 }
sleY1731MegRapsWestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the west port of R-APS node"
::= { sleY1731MegEntry 29 }
sleY1731MegRapsRplPort OBJECT-TYPE
SYNTAX INTEGER
{
none(-1),
east(0),
west(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the RPL port of R-APS node"
::= { sleY1731MegEntry 30 }
sleY1731MegRapsHoldOffTime OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the hold-off time for verifying local SF"
::= { sleY1731MegEntry 31 }
sleY1731MegRapsGuardTime OBJECT-TYPE
SYNTAX Integer32 (10..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the guard time for verifying local clear SF"
::= { sleY1731MegEntry 32 }
sleY1731MegRapsWaitToRestore OBJECT-TYPE
SYNTAX Integer32 (5..720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time for verifying remote SF"
::= { sleY1731MegEntry 33 }
sleY1731MegRapsState OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
idle(1),
protection(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the state of r-aps state machine"
::= { sleY1731MegEntry 34 }
sleY1731MegRapsEastPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
disabled(1),
forwarding(2),
blocking(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port status of east port."
::= { sleY1731MegEntry 35 }
sleY1731MegRapsWestPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
disabled(1),
forwarding(2),
blocking(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port status of west port."
::= { sleY1731MegEntry 36 }
sleY1731MegRapsNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NonRevertive"
::= { sleY1731MegEntry 37 }
sleY1731MegRapsForcedSwitchEast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ForcedSwitchEast"
::= { sleY1731MegEntry 38 }
sleY1731MegRapsForcedSwitchWest OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ForcedSwitchWest"
::= { sleY1731MegEntry 39 }
sleY1731MegMd OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MD name of MEG."
::= { sleY1731MegEntry 40 }
sleY1731MegControl OBJECT IDENTIFIER ::= { sleY1731Meg 2 }
sleY1731MegControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731Meg(1),
deleteY1731Meg(2),
setY1731MegMepEnable(3),
setY1731MegCcEnable(4),
setY1731MegCcProfile(5),
setY1731MegFaultProfile(6),
setY1731MegXcheckEnable(7),
setY1731MegAisEnable(8),
setY1731MegAisTransmitEnable(9),
setY1731MegAisProfile(10),
setY1731MegLckEnable(11),
setY1731MegLckTransmitEnable(12),
setY1731MegLckProfile(13),
setY1731MegOutOfService(14),
setY1731MegRapsEnable(15),
setY1731MegRapsRingports(16),
setY1731MegRapsRplPort(17),
setY1731MegRapsRplOwner(18),
setY1731MegRapsRplTimer(19),
destroyY1731MegRemoteMep(20),
destroyY1731MegError(21),
setY1731MegRapsNonRevertive(22),
setY1731MegRapsForcedSwitchEast(23),
setY1731MegRapsForcedSwitchWest(24),
addY1731MegMd(25),
delY1731MegMd(26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegControl 1 }
sleY1731MegControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegControl 2 }
sleY1731MegControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegControl 3 }
sleY1731MegControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegControl 4 }
sleY1731MegControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegControl 5 }
sleY1731MegControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's Index"
::= { sleY1731MegControl 6 }
sleY1731MegControlName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MEG's name: ICC (6 bytes) + UMC (6 bytes)"
::= { sleY1731MegControl 7 }
sleY1731MegControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's level"
::= { sleY1731MegControl 8 }
sleY1731MegControlVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's VID"
::= { sleY1731MegControl 9 }
sleY1731MegControlMepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables Y.1731 OAM for MEPs"
::= { sleY1731MegControl 10 }
sleY1731MegControlCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables MEPs to send Continuity Check messages"
::= { sleY1731MegControl 11 }
sleY1731MegControlCcInterval OBJECT-TYPE
SYNTAX Integer32 (1 | 2..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval between CCM transmissions"
::= { sleY1731MegControl 12 }
sleY1731MegControlCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the CCM or LTM Message Priority"
::= { sleY1731MegControl 13 }
sleY1731MegControlCcLossThreshold OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
::= { sleY1731MegControl 14 }
sleY1731MegControlCcHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the time that data of a missing MEP is kept"
::= { sleY1731MegControl 15 }
sleY1731MegControlFaultPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the lowest priority for fault alarm"
::= { sleY1731MegControl 16 }
sleY1731MegControlFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the keep time for the fault alarm"
::= { sleY1731MegControl 17 }
sleY1731MegControlFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the clear time for the fault alarm"
::= { sleY1731MegControl 18 }
sleY1731MegControlXcheckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables Y.1731 cross-check for a specific MEG"
::= { sleY1731MegControl 19 }
sleY1731MegControlAisEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables ETH-AIS function"
::= { sleY1731MegControl 20 }
sleY1731MegControlAisTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables ETH-AIS frame transmission on a MEP"
::= { sleY1731MegControl 21 }
sleY1731MegControlAisInterval OBJECT-TYPE
SYNTAX INTEGER
{
oneSecond(4),
oneMinute(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval between AIS transmissions"
::= { sleY1731MegControl 22 }
sleY1731MegControlAisLevel OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the client MEG's level"
::= { sleY1731MegControl 23 }
sleY1731MegControlAisPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the AIS Message Priority"
::= { sleY1731MegControl 24 }
sleY1731MegControlLckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables ETH-LCK function"
::= { sleY1731MegControl 25 }
sleY1731MegControlLckTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables ETH-LCK frame transmission on a MEP"
::= { sleY1731MegControl 26 }
sleY1731MegControlLckInterval OBJECT-TYPE
SYNTAX INTEGER
{
oneSecond(4),
oneMinute(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval between LCK transmissions"
::= { sleY1731MegControl 27 }
sleY1731MegControlLckLevel OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the client MEG's level"
::= { sleY1731MegControl 28 }
sleY1731MegControlLckPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the LCK Message Priority"
::= { sleY1731MegControl 29 }
sleY1731MegControlOutOfService OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the out-of-service mode"
::= { sleY1731MegControl 30 }
sleY1731MegControlRapsEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables R-APS node"
::= { sleY1731MegControl 31 }
sleY1731MegControlRapsRplOwner OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the owner of the ring protection link"
::= { sleY1731MegControl 32 }
sleY1731MegControlRapsEastPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the east port of R-APS node
Set zero to delete east port"
::= { sleY1731MegControl 33 }
sleY1731MegControlRapsWestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the west port of R-APS node
Set zero to delete west port"
::= { sleY1731MegControl 34 }
sleY1731MegControlRapsRplPort OBJECT-TYPE
SYNTAX INTEGER
{
none(-1),
east(0),
west(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the RPL port of R-APS node"
::= { sleY1731MegControl 35 }
sleY1731MegControlRapsHoldOffTime OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the hold-off time for verifying local SF
The hold-off time's step must be 100
"
::= { sleY1731MegControl 36 }
sleY1731MegControlRapsGuardTime OBJECT-TYPE
SYNTAX Integer32 (10..2000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the guard time for verifying local clear SF
The guard time's step must be 10
"
::= { sleY1731MegControl 37 }
sleY1731MegControlRapsWaitToRestore OBJECT-TYPE
SYNTAX Integer32 (5..720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time for verifying remote SF
"
::= { sleY1731MegControl 38 }
sleY1731MegControlRapsNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NonRevertive"
::= { sleY1731MegControl 39 }
sleY1731MegControlRapsForcedSwitchEast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ForcedSwitchEast"
::= { sleY1731MegControl 40 }
sleY1731MegControlRapsForcedSwitchWest OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ForcedSwitchWest"
::= { sleY1731MegControl 41 }
sleY1731MegControlMd OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MD name of MEG."
::= { sleY1731MegControl 42 }
sleY1731MegNotification OBJECT IDENTIFIER ::= { sleY1731Meg 3 }
sleY1731MegCreated NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlLevel,
sleY1731MegControlVid }
STATUS current
DESCRIPTION
"createY1731Meg"
::= { sleY1731MegNotification 1 }
sleY1731MegDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName }
STATUS current
DESCRIPTION
"deleteY1731Meg"
::= { sleY1731MegNotification 2 }
sleY1731MegMepEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlMepEnable }
STATUS current
DESCRIPTION
"setY1731MepEnable"
::= { sleY1731MegNotification 3 }
sleY1731MegCcEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlCcEnable
}
STATUS current
DESCRIPTION
"setY1731CcEnable"
::= { sleY1731MegNotification 4 }
sleY1731MegCcProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlCcInterval, sleY1731MegControlCcPriority, sleY1731MegControlCcLossThreshold, sleY1731MegControlCcHoldTime }
STATUS current
DESCRIPTION
"setY1731CcProfile"
::= { sleY1731MegNotification 5 }
sleY1731MegFaultProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlFaultPriority, sleY1731MegControlFaultKeepTime, sleY1731MegControlFaultClearTime }
STATUS current
DESCRIPTION
"setY1731FaultProfile"
::= { sleY1731MegNotification 6 }
sleY1731MegXcheckEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlXcheckEnable }
STATUS current
DESCRIPTION
"setY1731XcheckEnable"
::= { sleY1731MegNotification 7 }
sleY1731MegAisEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlAisEnable }
STATUS current
DESCRIPTION
"setY1731AisEnable"
::= { sleY1731MegNotification 8 }
sleY1731MegAisTransmitEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlAisTransmitEnable }
STATUS current
DESCRIPTION
"setY1731AisTransmitEnable"
::= { sleY1731MegNotification 9 }
sleY1731MegAisProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlAisInterval, sleY1731MegControlAisLevel, sleY1731MegControlAisPriority }
STATUS current
DESCRIPTION
"setY1731AisProfile"
::= { sleY1731MegNotification 10 }
sleY1731MegLckEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlLckEnable }
STATUS current
DESCRIPTION
"setY1731LckEnable"
::= { sleY1731MegNotification 11 }
sleY1731MegLckTransmitEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlLckTransmitEnable }
STATUS current
DESCRIPTION
"setY1731LckTransmitEnable"
::= { sleY1731MegNotification 12 }
sleY1731MegLckProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlLckInterval, sleY1731MegControlLckLevel, sleY1731MegControlLckPriority }
STATUS current
DESCRIPTION
"setY1731LckProfile"
::= { sleY1731MegNotification 13 }
sleY1731MegOutOfServiceChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlOutOfService }
STATUS current
DESCRIPTION
"setY1731OutOfService"
::= { sleY1731MegNotification 14 }
sleY1731MegRapsEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlRapsEnable }
STATUS current
DESCRIPTION
"setY1731RapsEnable"
::= { sleY1731MegNotification 15 }
sleY1731MegRapsRingportsChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlRapsEastPort, sleY1731MegControlRapsWestPort }
STATUS current
DESCRIPTION
"setY1731RapsProfile"
::= { sleY1731MegNotification 16 }
sleY1731MegRapsRplPortChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlRapsRplPort }
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegNotification 17 }
sleY1731MegRapsRplOwnerChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlRapsRplOwner }
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegNotification 18 }
sleY1731MegRapsTimerChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName,
sleY1731MegControlRapsHoldOffTime, sleY1731MegControlRapsGuardTime, sleY1731MegControlRapsWaitToRestore }
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MegNotification 19 }
sleY1731MegRemoteMepDestroyed NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex }
STATUS current
DESCRIPTION
"destroyRemoteMep"
::= { sleY1731MegNotification 20 }
sleY1731MegErrorDestroyed NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex }
STATUS current
DESCRIPTION
"destroyError"
::= { sleY1731MegNotification 21 }
sleY1731MegRapsNonRevertiveChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsNonRevertive
}
STATUS current
DESCRIPTION
"sleY1731MegRapsNonRevertiveChanged"
::= { sleY1731MegNotification 22 }
sleY1731MegRapsForcedSwitchEastChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsForcedSwitchEast
}
STATUS current
DESCRIPTION
"sleY1731MegRapsForcedSwitchEastChanged"
::= { sleY1731MegNotification 23 }
sleY1731MegRapsForcedSwitchWestChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlRapsForcedSwitchWest
}
STATUS current
DESCRIPTION
"sleY1731MegRapsForcedSwitchWestChanged"
::= { sleY1731MegNotification 24 }
sleY1731MegMdAdded NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlMd
}
STATUS current
DESCRIPTION
"createY1731Meg"
::= { sleY1731MegNotification 25 }
sleY1731MegMdDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731MegControlRequest, sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlName, sleY1731MegControlMd
}
STATUS current
DESCRIPTION
"createY1731Meg"
::= { sleY1731MegNotification 26 }
sleY1731Mep OBJECT IDENTIFIER ::= { sleY1731Oam 3 }
sleY1731MepTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731MepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731Mep 1 }
sleY1731MepEntry OBJECT-TYPE
SYNTAX SleY1731MepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier }
::= { sleY1731MepTable 1 }
SleY1731MepEntry ::=
SEQUENCE {
sleY1731MepIdentifier
Integer32,
sleY1731MepIfIndex
Integer32,
sleY1731MepDirection
INTEGER,
sleY1731MepEnable
INTEGER,
sleY1731MepFngState
INTEGER,
sleY1731MepCcEnable
INTEGER,
sleY1731MepMacAddress
OCTET STRING,
sleY1731MepFaultPriority
INTEGER,
sleY1731MepFaultKeepTime
Integer32,
sleY1731MepFaultClearTime
Integer32,
sleY1731MepHighestPrDefect
INTEGER,
sleY1731MepAisEnable
INTEGER,
sleY1731MepAisTransmitEnable
INTEGER,
sleY1731MepLckEnable
INTEGER,
sleY1731MepLckTransmitEnable
INTEGER,
sleY1731MepOutOfService
INTEGER,
sleY1731MepDlmEnabledRmep
Integer32,
sleY1731MepDefects
BITS,
sleY1731MepCcmSequenceErrors
Counter32,
sleY1731MepCciSentCcms
Counter32,
sleY1731MepNextLbmTransId
Integer32,
sleY1731MepLbSuccessRate
Integer32,
sleY1731MepLbRoundtripMin
Counter32,
sleY1731MepLbRoundtripMax
Counter32,
sleY1731MepLbRoundtripAvg
Counter32,
sleY1731MepLbrIn
Counter32,
sleY1731MepLbrInOutOfOrder
Counter32,
sleY1731MepTstLbrInBitError
Counter32,
sleY1731MepTstLbrInCrcError
Counter32,
sleY1731MepLtmNextSeqNumber
Integer32,
sleY1731MepUnexpLtrIn
Counter32,
sleY1731MepLbrOut
Counter32,
sleY1731MepTmLbmCount
Integer32,
sleY1731MepTmLbrCount
Integer32,
sleY1731MepTmLbrFirstLostId
Integer32,
sleY1731MepTmLbrMaxRate
Integer32,
sleY1731MepTmTstCount
Integer32,
sleY1731MepCcmFrameLossNearMin
Integer32,
sleY1731MepCcmFrameLossNearMax
Integer32,
sleY1731MepCcmFrameLossNearSum
Integer32,
sleY1731MepCcmFrameLossFarMin
Integer32,
sleY1731MepCcmFrameLossFarMax
Integer32,
sleY1731MepCcmFrameLossFarSum
Integer32,
sleY1731MepPmEnable
INTEGER,
sleY1731MepCcmFrameLossNearRatio
Integer32,
sleY1731MepCcmFrameLossNearAvgRatio
Integer32,
sleY1731MepCcmFrameLossFarRatio
Integer32,
sleY1731MepCcmFrameLossFarAvgRatio
Integer32,
sleY1731MepRllcf
INTEGER,
sleY1731MepRllcfHoldOff
Integer32,
sleY1731MepRllcfGuardTime
Integer32
}
sleY1731MepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MEP Id"
::= { sleY1731MepEntry 1 }
sleY1731MepIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Brige Port Index whitch the MEP is attached"
::= { sleY1731MepEntry 2 }
sleY1731MepDirection OBJECT-TYPE
SYNTAX INTEGER
{
down(0),
up(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction in which the MEP faces on the Bridge port"
::= { sleY1731MepEntry 3 }
sleY1731MepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Administrative state of the MEP"
::= { sleY1731MepEntry 4 }
sleY1731MepFngState OBJECT-TYPE
SYNTAX INTEGER
{
reset(1),
defect(2),
reportDefect(3),
defectReported(4),
defectCearing(5),
defectCleared(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of the MEP Fault Notification Generator State Machine"
::= { sleY1731MepEntry 5 }
sleY1731MepCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the MEP will generate CCM messages"
::= { sleY1731MepEntry 6 }
sleY1731MepMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MEP"
::= { sleY1731MepEntry 7 }
sleY1731MepFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdi(1),
loc(2),
unp(3),
unm(4),
mmg(5),
unl(6),
ais(7),
lck(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
::= { sleY1731MepEntry 8 }
sleY1731MepFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that defects must be present before a Fault Alarm is issued"
::= { sleY1731MepEntry 9 }
sleY1731MepFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that defects must be absent before resetting a Fault Alarm"
::= { sleY1731MepEntry 10 }
sleY1731MepHighestPrDefect OBJECT-TYPE
SYNTAX INTEGER
{
rdi(1),
loc(2),
unp(3),
unm(4),
mmg(5),
unl(6),
ais(7),
lck(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine was last in the FNG_RESET state"
::= { sleY1731MepEntry 11 }
sleY1731MepAisEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the AIS function for the MEP is enabled"
::= { sleY1731MepEntry 12 }
sleY1731MepAisTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the MEP can generate AIS messages"
::= { sleY1731MepEntry 13 }
sleY1731MepLckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the LCK function for the MEP is enabled"
::= { sleY1731MepEntry 14 }
sleY1731MepLckTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the MEP can generate LCK messages"
::= { sleY1731MepEntry 15 }
sleY1731MepOutOfService OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the MEP is in out-of-service."
::= { sleY1731MepEntry 16 }
sleY1731MepDlmEnabledRmep OBJECT-TYPE
SYNTAX Integer32 (0..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RMEP identifier enabled DLM functin
If set to zero, disabled DLM function.
"
::= { sleY1731MepEntry 17 }
sleY1731MepDefects OBJECT-TYPE
SYNTAX BITS
{
rdi(0),
loc(1),
unp(2),
unm(3),
mmg(4),
unl(5),
ais(6),
lck(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A vector of Boolean defect conditions"
::= { sleY1731MepEntry 18 }
sleY1731MepCcmSequenceErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of out-of-sequence CCMs received from all remote MEPs"
::= { sleY1731MepEntry 19 }
sleY1731MepCciSentCcms OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Continuity Check messages transmitted"
::= { sleY1731MepEntry 20 }
sleY1731MepNextLbmTransId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next sequence number/transaction identifier to be sent in a Loopback message"
::= { sleY1731MepEntry 21 }
sleY1731MepLbSuccessRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loopback Success rate"
::= { sleY1731MepEntry 22 }
sleY1731MepLbRoundtripMin OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum round trip time of Loopback message"
::= { sleY1731MepEntry 23 }
sleY1731MepLbRoundtripMax OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum round trip time of Loopback message"
::= { sleY1731MepEntry 24 }
sleY1731MepLbRoundtripAvg OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip time of Loopback message"
::= { sleY1731MepEntry 25 }
sleY1731MepLbrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, in-order Loopback Replies received"
::= { sleY1731MepEntry 26 }
sleY1731MepLbrInOutOfOrder OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid, out-of-order Loopback Replies received"
::= { sleY1731MepEntry 27 }
sleY1731MepTstLbrInBitError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of invalid, bit-error Loopback Replies received for diagnostic test"
::= { sleY1731MepEntry 28 }
sleY1731MepTstLbrInCrcError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of invalid, crc-error Loopback Replies received for diagnostic test"
::= { sleY1731MepEntry 29 }
sleY1731MepLtmNextSeqNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next transaction identifier/sequence number to be sent in a Linktrace message."
::= { sleY1731MepEntry 30 }
sleY1731MepUnexpLtrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of unexpected LTRs received"
::= { sleY1731MepEntry 31 }
sleY1731MepLbrOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Loopback Replies transmitted"
::= { sleY1731MepEntry 32 }
sleY1731MepTmLbmCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the count of LBM frame for the throughput-measurement"
::= { sleY1731MepEntry 33 }
sleY1731MepTmLbrCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the count of LBM frame for the throughput-measurement"
::= { sleY1731MepEntry 34 }
sleY1731MepTmLbrFirstLostId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the transaction identifier of first lost LBR frame for the throughput-measurement"
::= { sleY1731MepEntry 35 }
sleY1731MepTmLbrMaxRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum transmission rate"
::= { sleY1731MepEntry 36 }
sleY1731MepTmTstCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the count of TST message for the throughput-measurement"
::= { sleY1731MepEntry 37 }
sleY1731MepCcmFrameLossNearMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum of dual-ended near-end frame loss"
::= { sleY1731MepEntry 38 }
sleY1731MepCcmFrameLossNearMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum of dual-ended near-end frame loss"
::= { sleY1731MepEntry 39 }
sleY1731MepCcmFrameLossNearSum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the sum of dual-ended near-end frame loss"
::= { sleY1731MepEntry 40 }
sleY1731MepCcmFrameLossFarMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum of dual-ended far-end frame loss"
::= { sleY1731MepEntry 41 }
sleY1731MepCcmFrameLossFarMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum of dual-ended far-end frame loss"
::= { sleY1731MepEntry 42 }
sleY1731MepCcmFrameLossFarSum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the sum of dual-ended far-end frame loss"
::= { sleY1731MepEntry 43 }
sleY1731MepPmEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the PM(performance monitoring) of the MEP is enabled"
::= { sleY1731MepEntry 44 }
sleY1731MepCcmFrameLossNearRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ratio of dual-ended near-end frame loss"
::= { sleY1731MepEntry 45 }
sleY1731MepCcmFrameLossNearAvgRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the average ratio of dual-ended near-end frame loss"
::= { sleY1731MepEntry 46 }
sleY1731MepCcmFrameLossFarRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ratio of dual-ended far-end frame loss"
::= { sleY1731MepEntry 47 }
sleY1731MepCcmFrameLossFarAvgRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the average ratio of dual-ended far-end frame loss"
::= { sleY1731MepEntry 48 }
sleY1731MepRllcf OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the MEP is a MEP of client link for remote link loss carry forward."
::= { sleY1731MepEntry 49 }
sleY1731MepRllcfHoldOff OBJECT-TYPE
SYNTAX Integer32 (10..3000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is a Hold-off time of Remote LLCF and its unit is millisecond, interval is 10ms."
::= { sleY1731MepEntry 50 }
sleY1731MepRllcfGuardTime OBJECT-TYPE
SYNTAX Integer32 (100..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"It is a Guard time of Remote LLCF and its unit is millisecond, interval is 100ms.(default:500)"
::= { sleY1731MepEntry 51 }
sleY1731MepControl OBJECT IDENTIFIER ::= { sleY1731Mep 2 }
sleY1731MepControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731Mep(1),
deleteY1731Mep(2),
setY1731MepEnable(3),
setY1731MepCcEnable(4),
setY1731MepFaultProfile(5),
setY1731MepAisEnable(6),
setY1731MepAisTransmitEnable(7),
setY1731MepLckEnable(8),
setY1731MepLckTransmitEnable(9),
setY1731MepOutOfService(10),
setY1731MepDlmEnable(11),
transmitY1731Lbm(12),
transmitY1731Ltm(13),
transmitY1731TstLbm(14),
transmitY1731TmLbm(15),
transmitY1731Tst(16),
receiveY1731Tst(17),
transmitY1731TmTst(18),
receiveY1731TmTst(19),
transmitY1731Lmm(20),
transmitY17311dm(21),
receiveY17311dm(22),
transmitY1731dmm(23),
setY1731MepPmEnable(24),
setY1731MepRllcf(25)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MepControl 1 }
sleY1731MepControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MepControl 2 }
sleY1731MepControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MepControl 3 }
sleY1731MepControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MepControl 4 }
sleY1731MepControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MepControl 5 }
sleY1731MepControlIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MEP Id"
::= { sleY1731MepControl 6 }
sleY1731MepControlMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A index of MEG table"
::= { sleY1731MepControl 7 }
sleY1731MepControlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridge Port Index whitch the MEP is attached"
::= { sleY1731MepControl 8 }
sleY1731MepControlDirection OBJECT-TYPE
SYNTAX INTEGER
{
down(0),
up(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The direction in which the MEP faces on the Bridge port"
::= { sleY1731MepControl 9 }
sleY1731MepControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative state of the MEP"
::= { sleY1731MepControl 10 }
sleY1731MepControlCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the MEP will generate CCM messages"
::= { sleY1731MepControl 11 }
sleY1731MepControlFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdi(1),
loc(2),
unp(3),
unm(4),
mmg(5),
unl(6),
ais(7),
lck(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
::= { sleY1731MepControl 12 }
sleY1731MepControlFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time that defects must be present before a Fault Alarm is issued"
::= { sleY1731MepControl 13 }
sleY1731MepControlFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time that defects must be absent before resetting a Fault Alarm"
::= { sleY1731MepControl 14 }
sleY1731MepControlAisEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the AIS function for the MEP is enabled"
::= { sleY1731MepControl 15 }
sleY1731MepControlAisTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the MEP can generate AIS messages"
::= { sleY1731MepControl 16 }
sleY1731MepControlLckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the LCK function for the MEP is enabled"
::= { sleY1731MepControl 17 }
sleY1731MepControlLckTransmitEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the MEP can generate LCK messages"
::= { sleY1731MepControl 18 }
sleY1731MepControlOutOfService OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the MEP is in out-of-service."
::= { sleY1731MepControl 19 }
sleY1731MepControlDlmEnabledRmep OBJECT-TYPE
SYNTAX Integer32 (0..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RMEP identifier enabled DLM functin
If set to zero, disabled DLM function.
"
::= { sleY1731MepControl 20 }
sleY1731MepControlTransmitLbmIsUnicast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates transmitting unicast or multicast frame"
::= { sleY1731MepControl 21 }
sleY1731MepControlTransmitLbmDestMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted"
::= { sleY1731MepControl 22 }
sleY1731MepControlTransmitLbmDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
::= { sleY1731MepControl 23 }
sleY1731MepControlTransmitLbmDestIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True indicates that MEPID of the target MEP is used for Loopback transmission"
::= { sleY1731MepControl 24 }
sleY1731MepControlTransmitLbmCount OBJECT-TYPE
SYNTAX Integer32 (1..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of Loopback messages to be transmitted"
::= { sleY1731MepControl 25 }
sleY1731MepControlTransmitLbmInterval OBJECT-TYPE
SYNTAX Integer32 (2..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending LBM"
::= { sleY1731MepControl 26 }
sleY1731MepControlTransmitLbmTimeout OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the waiting time for receiving the expected LBR"
::= { sleY1731MepControl 27 }
sleY1731MepControlTransmitLbmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 28 }
sleY1731MepControlTransmitLbmLength OBJECT-TYPE
SYNTAX Integer32 (5..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the length of Data TLV"
::= { sleY1731MepControl 29 }
sleY1731MepControlTransmitLtmTargetMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted: A unicast destination MAC address."
::= { sleY1731MepControl 30 }
sleY1731MepControlTransmitLtmTargetMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An indication of the Target MAC Address Field to be transmitted"
::= { sleY1731MepControl 31 }
sleY1731MepControlTransmitLtmTargetIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True indicates that MEPID of the target MEP is used for Linktrace transmission."
::= { sleY1731MepControl 32 }
sleY1731MepControlTransmitLtmFlags OBJECT-TYPE
SYNTAX BITS { useFDBonly(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The flags field for LTMs transmitted by the MEP"
::= { sleY1731MepControl 33 }
sleY1731MepControlTransmitLtmTtl OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LTM TTL field"
::= { sleY1731MepControl 34 }
sleY1731MepControlTransmitLtmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 35 }
sleY1731MepControlTransmitTstLbmDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
::= { sleY1731MepControl 36 }
sleY1731MepControlTransmitTstLbmDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to send LBM"
::= { sleY1731MepControl 37 }
sleY1731MepControlTransmitTstLbmInterval OBJECT-TYPE
SYNTAX Integer32 (2..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending LBM"
::= { sleY1731MepControl 38 }
sleY1731MepControlTransmitTstLbmTimeout OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the waiting time for receiving the expected LBR"
::= { sleY1731MepControl 39 }
sleY1731MepControlTransmitTstLbmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 40 }
sleY1731MepControlTransmitTstLbmLength OBJECT-TYPE
SYNTAX Integer32 (5..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the length of Test TLV"
::= { sleY1731MepControl 41 }
sleY1731MepControlTransmitTstLbmPattern OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the pattern of Test TLV used for diagnostic test"
::= { sleY1731MepControl 42 }
sleY1731MepControlTransmitTmLbmDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
::= { sleY1731MepControl 43 }
sleY1731MepControlTransmitTmLbmDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to send LBM"
::= { sleY1731MepControl 44 }
sleY1731MepControlTransmitTmLbmPartDuration OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the part duration of LBM to be transmitted at the same transmission rate"
::= { sleY1731MepControl 45 }
sleY1731MepControlTransmitTmLbmStartRate OBJECT-TYPE
SYNTAX Integer32 (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the the number of LBMs to be transmitted per second at first time"
::= { sleY1731MepControl 46 }
sleY1731MepControlTransmitTmLbmIncRate OBJECT-TYPE
SYNTAX Integer32 (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the increment of number of LBMs to be transmitted"
::= { sleY1731MepControl 47 }
sleY1731MepControlTransmitTmLbmTimeout OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the waiting time for receiving the expected LBR"
::= { sleY1731MepControl 48 }
sleY1731MepControlTransmitTmLbmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 49 }
sleY1731MepControlTransmitTmLbmLength OBJECT-TYPE
SYNTAX Integer32 (5..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the length of Test TLV"
::= { sleY1731MepControl 50 }
sleY1731MepControlTransmitTmLbmPattern OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the pattern of Test TLV used for diagnostic test"
::= { sleY1731MepControl 51 }
sleY1731MepControlTransmitTstIsUnicast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates transmitting unicast or multicast frame"
::= { sleY1731MepControl 52 }
sleY1731MepControlTransmitTstDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the TST is to be sent"
::= { sleY1731MepControl 53 }
sleY1731MepControlTransmitTstDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to send TST"
::= { sleY1731MepControl 54 }
sleY1731MepControlTransmitTstInterval OBJECT-TYPE
SYNTAX Integer32 (2..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending TST"
::= { sleY1731MepControl 55 }
sleY1731MepControlTransmitTstPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 56 }
sleY1731MepControlTransmitTstLength OBJECT-TYPE
SYNTAX Integer32 (5..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the length of Test TLV"
::= { sleY1731MepControl 57 }
sleY1731MepControlTransmitTstPattern OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the pattern of Test TLV used for diagnostic test"
::= { sleY1731MepControl 58 }
sleY1731MepControlReceiveTstDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to receive TST"
::= { sleY1731MepControl 59 }
sleY1731MepControlTransmitTmTstIsUnicast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates transmitting unicast or multicast frame"
::= { sleY1731MepControl 60 }
sleY1731MepControlTransmitTmTstDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the TST is to be sent"
::= { sleY1731MepControl 61 }
sleY1731MepControlTransmitTmTstDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to send TST"
::= { sleY1731MepControl 62 }
sleY1731MepControlTransmitTmTstPartDuration OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the part duration of TST to be transmitted at the same transmission rate"
::= { sleY1731MepControl 63 }
sleY1731MepControlTransmitTmTstStartRate OBJECT-TYPE
SYNTAX Integer32 (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the the number of TSTs to be transmitted per second at first time"
::= { sleY1731MepControl 64 }
sleY1731MepControlTransmitTmTstIncRate OBJECT-TYPE
SYNTAX Integer32 (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the increment of number of TSTs to be transmitted"
::= { sleY1731MepControl 65 }
sleY1731MepControlTransmitTmTstTimeout OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the waiting time for receiving the expected LBR"
::= { sleY1731MepControl 66 }
sleY1731MepControlTransmitTmTstPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 67 }
sleY1731MepControlTransmitTmTstLength OBJECT-TYPE
SYNTAX Integer32 (5..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the length of Test TLV"
::= { sleY1731MepControl 68 }
sleY1731MepControlTransmitTmTstPattern OBJECT-TYPE
SYNTAX Integer32 (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the pattern of Test TLV used for diagnostic test"
::= { sleY1731MepControl 69 }
sleY1731MepControlReceiveTmTstDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to receive TST"
::= { sleY1731MepControl 70 }
sleY1731MepControlTransmitLmmIsUnicast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A flag to indicates transmitting unicast or multicast frame"
::= { sleY1731MepControl 71 }
sleY1731MepControlTransmitLmmDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LMM is to be sent"
::= { sleY1731MepControl 72 }
sleY1731MepControlTransmitLmmDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to send LMM"
::= { sleY1731MepControl 73 }
sleY1731MepControlTransmitLmmInterval OBJECT-TYPE
SYNTAX Integer32 (2..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending LMM"
::= { sleY1731MepControl 74 }
sleY1731MepControlTransmitLmmTimeout OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the waiting time for receiving the expected LMM"
::= { sleY1731MepControl 75 }
sleY1731MepControlTransmitLmmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 76 }
sleY1731MepControlTransmit1dmIsUnicast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A flag to indicates transmitting unicast or multicast frame"
::= { sleY1731MepControl 77 }
sleY1731MepControlTransmit1dmDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the 1DM is to be sent"
::= { sleY1731MepControl 78 }
sleY1731MepControlTransmit1dmDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to send 1DM"
::= { sleY1731MepControl 79 }
sleY1731MepControlTransmit1dmInterval OBJECT-TYPE
SYNTAX Integer32 (2..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending 1DM"
::= { sleY1731MepControl 80 }
sleY1731MepControlTransmit1dmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 81 }
sleY1731MepControlReceive1dmDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to receive 1DM"
::= { sleY1731MepControl 82 }
sleY1731MepControlTransmitDmmIsUnicast OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A flag to indicates transmitting unicast or multicast frame"
::= { sleY1731MepControl 83 }
sleY1731MepControlTransmitDmmDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the DMM is to be sent"
::= { sleY1731MepControl 84 }
sleY1731MepControlTransmitDmmDuration OBJECT-TYPE
SYNTAX Integer32 (5..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duration to send DMM"
::= { sleY1731MepControl 85 }
sleY1731MepControlTransmitDmmInterval OBJECT-TYPE
SYNTAX Integer32 (2..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending DMM"
::= { sleY1731MepControl 86 }
sleY1731MepControlTransmitDmmTimeout OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the waiting time for receiving the expected DMM"
::= { sleY1731MepControl 87 }
sleY1731MepControlTransmitDmmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleY1731MepControl 88 }
sleY1731MepControlPmEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the PM(performance monitoring) of the MEP is enabled"
::= { sleY1731MepControl 89 }
sleY1731MepControlRllcf OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the MEP is a MEP of client link for remote link loss carry forward."
::= { sleY1731MepControl 90 }
sleY1731MepControlRllcfHoldOff OBJECT-TYPE
SYNTAX Integer32 (10..3000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is a Hold-off time of Remote LLCF and its unit is millisecond, interval is 10ms."
::= { sleY1731MepControl 91 }
sleY1731MepControlRllcfGuardTime OBJECT-TYPE
SYNTAX Integer32 (100..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is a Guard time of Remote LLCF and its unit is millisecond, interval is 100ms.(default:500)"
::= { sleY1731MepControl 92 }
sleY1731MepNotification OBJECT IDENTIFIER ::= { sleY1731Mep 3 }
sleY1731MepCreated NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlIfIndex, sleY1731MepControlDirection }
STATUS current
DESCRIPTION
"createY1731Mep"
::= { sleY1731MepNotification 1 }
sleY1731MepDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"deleteY1731Mep"
::= { sleY1731MepNotification 2 }
sleY1731MepEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlEnable }
STATUS current
DESCRIPTION
"setY1731MepEnable"
::= { sleY1731MepNotification 3 }
sleY1731MepCcEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlCcEnable }
STATUS current
DESCRIPTION
"setY1731CcEnable"
::= { sleY1731MepNotification 4 }
sleY1731MepFaultProfileChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlFaultPriority, sleY1731MepControlFaultKeepTime, sleY1731MepControlFaultClearTime }
STATUS current
DESCRIPTION
"setY1731FaultProfile"
::= { sleY1731MepNotification 5 }
sleY1731MepAisEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlAisEnable }
STATUS current
DESCRIPTION
"setY1731AisEnable"
::= { sleY1731MepNotification 6 }
sleY1731MepAisTransmitEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlAisTransmitEnable }
STATUS current
DESCRIPTION
"setY1731AisTransmitEnable"
::= { sleY1731MepNotification 7 }
sleY1731MepLckEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlLckEnable }
STATUS current
DESCRIPTION
"setY1731LckEnable"
::= { sleY1731MepNotification 8 }
sleY1731MepLckTransmitEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlLckTransmitEnable }
STATUS current
DESCRIPTION
"setY1731LckTransmitEnable"
::= { sleY1731MepNotification 9 }
sleY1731MepOutOfServiceChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlOutOfService }
STATUS current
DESCRIPTION
"setY1731OutOfService"
::= { sleY1731MepNotification 10 }
sleY1731MepDlmEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlDlmEnabledRmep }
STATUS current
DESCRIPTION
"setY1731DlmEnable"
::= { sleY1731MepNotification 11 }
sleY1731MepTransmitLbmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731Lbm"
::= { sleY1731MepNotification 12 }
sleY1731MepTransmitLtmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731Ltm"
::= { sleY1731MepNotification 13 }
sleY1731MepTransmitTstLbmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731TstLbm"
::= { sleY1731MepNotification 14 }
sleY1731MepTransmitTmLbmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731TmLbm"
::= { sleY1731MepNotification 15 }
sleY1731MepTransmitTstFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731Tst"
::= { sleY1731MepNotification 16 }
sleY1731MepReceiveTstFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"receiveY1731Tst"
::= { sleY1731MepNotification 17 }
sleY1731MepTransmitTmTstFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731TmTst"
::= { sleY1731MepNotification 18 }
sleY1731MepReceiveTmTstFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"receiveY1731TmTst"
::= { sleY1731MepNotification 19 }
sleY1731MepTransmitLmmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731Lmm"
::= { sleY1731MepNotification 20 }
sleY1731MepTransmit1dmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY17311dm"
::= { sleY1731MepNotification 21 }
sleY1731MepReceive1dmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"receiveY17311dm"
::= { sleY1731MepNotification 22 }
sleY1731MepTransmitDmmFinished NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex
}
STATUS current
DESCRIPTION
"transmitY1731Dmm"
::= { sleY1731MepNotification 23 }
sleY1731MepPmEnableChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlPmEnable }
STATUS current
DESCRIPTION
"setY1731PmEnable"
::= { sleY1731MepNotification 24 }
sleY1731MepRllcfChanged NOTIFICATION-TYPE
OBJECTS { sleY1731MepControlRequest, sleY1731MepControlTimeStamp, sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex,
sleY1731MepControlRllcf, sleY1731MepControlRllcfHoldOff, sleY1731MepControlRllcfGuardTime }
STATUS current
DESCRIPTION
"setY1731MepRllcf"
::= { sleY1731MepNotification 25 }
sleY1731Mip OBJECT IDENTIFIER ::= { sleY1731Oam 4 }
sleY1731MipTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731MipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731Mip 1 }
sleY1731MipEntry OBJECT-TYPE
SYNTAX SleY1731MipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MipPort }
::= { sleY1731MipTable 1 }
SleY1731MipEntry ::=
SEQUENCE {
sleY1731MipPort
Integer32,
sleY1731MipLevel
Integer32,
sleY1731MipType
INTEGER
}
sleY1731MipPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the port number"
::= { sleY1731MipEntry 1 }
sleY1731MipLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MIP's level"
::= { sleY1731MipEntry 2 }
sleY1731MipType OBJECT-TYPE
SYNTAX INTEGER
{
static(1),
dynamic(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the MIP<49><50>s type"
::= { sleY1731MipEntry 3 }
sleY1731MipControl OBJECT IDENTIFIER ::= { sleY1731Mip 2 }
sleY1731MipControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731Mip(1),
deleteY1731Mip(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MipControl 1 }
sleY1731MipControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MipControl 2 }
sleY1731MipControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MipControl 3 }
sleY1731MipControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MipControl 4 }
sleY1731MipControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MipControl 5 }
sleY1731MipControlPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the port number"
::= { sleY1731MipControl 6 }
sleY1731MipControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MIP's level"
::= { sleY1731MipControl 7 }
sleY1731MipNotification OBJECT IDENTIFIER ::= { sleY1731Mip 3 }
sleY1731MipCreated NOTIFICATION-TYPE
OBJECTS { sleY1731MipControlRequest, sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort, sleY1731MipControlLevel
}
STATUS current
DESCRIPTION
"createY1731Mip"
::= { sleY1731MipNotification 1 }
sleY1731MipDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731MipControlRequest, sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort }
STATUS current
DESCRIPTION
"deleteY1731Mip"
::= { sleY1731MipNotification 2 }
sleY1731Xcheck OBJECT IDENTIFIER ::= { sleY1731Oam 5 }
sleY1731XcheckTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731XcheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731Xcheck 1 }
sleY1731XcheckEntry OBJECT-TYPE
SYNTAX SleY1731XcheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731XcheckMepIdentifier }
::= { sleY1731XcheckTable 1 }
SleY1731XcheckEntry ::=
SEQUENCE {
sleY1731XcheckMepIdentifier
Integer32,
sleY1731XcheckMepState
INTEGER
}
sleY1731XcheckMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the remote MEP's Id"
::= { sleY1731XcheckEntry 1 }
sleY1731XcheckMepState OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
missing(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the cross-check MEP<45><50>s state"
::= { sleY1731XcheckEntry 2 }
sleY1731XcheckControl OBJECT IDENTIFIER ::= { sleY1731Xcheck 2 }
sleY1731XcheckControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731XcheckMep(1),
deleteY1731XcheckMep(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731XcheckControl 1 }
sleY1731XcheckControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731XcheckControl 2 }
sleY1731XcheckControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731XcheckControl 3 }
sleY1731XcheckControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731XcheckControl 4 }
sleY1731XcheckControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731XcheckControl 5 }
sleY1731XcheckControlMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the remote MEP's Id"
::= { sleY1731XcheckControl 6 }
sleY1731XcheckControlMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG<45><47>s Index"
::= { sleY1731XcheckControl 7 }
sleY1731XcheckNotification OBJECT IDENTIFIER ::= { sleY1731Xcheck 3 }
sleY1731XcheckMepCreated NOTIFICATION-TYPE
OBJECTS { sleY1731XcheckControlRequest, sleY1731XcheckControlTimeStamp, sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex
}
STATUS current
DESCRIPTION
"createY1731XcheckMep"
::= { sleY1731XcheckNotification 1 }
sleY1731XcheckMepDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731XcheckControlRequest, sleY1731XcheckControlTimeStamp, sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex
}
STATUS current
DESCRIPTION
"deleteY1731XcheckMep"
::= { sleY1731XcheckNotification 2 }
sleY1731CcMac OBJECT IDENTIFIER ::= { sleY1731Oam 6 }
sleY1731CcMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731CcMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731CcMac 1 }
sleY1731CcMacEntry OBJECT-TYPE
SYNTAX SleY1731CcMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731CcMacAddress }
::= { sleY1731CcMacTable 1 }
SleY1731CcMacEntry ::=
SEQUENCE {
sleY1731CcMacAddress
OCTET STRING
}
sleY1731CcMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the unicast MAC address to send CCM"
::= { sleY1731CcMacEntry 1 }
sleY1731CcMacControl OBJECT IDENTIFIER ::= { sleY1731CcMac 2 }
sleY1731CcMacControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731CcMac(1),
deleteY1731CcMac(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731CcMacControl 1 }
sleY1731CcMacControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731CcMacControl 2 }
sleY1731CcMacControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731CcMacControl 3 }
sleY1731CcMacControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731CcMacControl 4 }
sleY1731CcMacControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the last command."
::= { sleY1731CcMacControl 5 }
sleY1731CcMacControlMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's Index"
::= { sleY1731CcMacControl 6 }
sleY1731CcMacControlMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MEP Id"
::= { sleY1731CcMacControl 7 }
sleY1731CcMacControlAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the unicast MAC address to send CCM
When running deleteY1731CcMac, if this is zero-length, delete all unicast mac."
::= { sleY1731CcMacControl 8 }
sleY1731CcMacNotification OBJECT IDENTIFIER ::= { sleY1731CcMac 3 }
sleY1731CcMacCreated NOTIFICATION-TYPE
OBJECTS { sleY1731CcMacControlRequest, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex, sleY1731CcMacControlMepIdentifier,
sleY1731CcMacControlAddress }
STATUS current
DESCRIPTION
"createY1731CcMac"
::= { sleY1731CcMacNotification 1 }
sleY1731CcMacDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731CcMacControlRequest, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex, sleY1731CcMacControlMepIdentifier,
sleY1731CcMacControlAddress }
STATUS current
DESCRIPTION
"deleteY1731CcMac"
::= { sleY1731CcMacNotification 2 }
sleY1731AisMac OBJECT IDENTIFIER ::= { sleY1731Oam 7 }
sleY1731AisMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731AisMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731AisMac 1 }
sleY1731AisMacEntry OBJECT-TYPE
SYNTAX SleY1731AisMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731AisMacAddress }
::= { sleY1731AisMacTable 1 }
SleY1731AisMacEntry ::=
SEQUENCE {
sleY1731AisMacAddress
OCTET STRING
}
sleY1731AisMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the unicast MAC address to send AIS"
::= { sleY1731AisMacEntry 1 }
sleY1731AisMacControl OBJECT IDENTIFIER ::= { sleY1731AisMac 2 }
sleY1731AisMacControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731AisMac(1),
deleteY1731AisMac(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731AisMacControl 1 }
sleY1731AisMacControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731AisMacControl 2 }
sleY1731AisMacControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731AisMacControl 3 }
sleY1731AisMacControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731AisMacControl 4 }
sleY1731AisMacControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731AisMacControl 5 }
sleY1731AisMacControlMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's Index"
::= { sleY1731AisMacControl 6 }
sleY1731AisMacControlMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MEP Id"
::= { sleY1731AisMacControl 7 }
sleY1731AisMacControlAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the unicast MAC address to send AIS
When running deleteY1731AisMac, if this is zero-length, delete all unicast mac."
::= { sleY1731AisMacControl 8 }
sleY1731AisMacNotification OBJECT IDENTIFIER ::= { sleY1731AisMac 3 }
sleY1731AisMacCreated NOTIFICATION-TYPE
OBJECTS { sleY1731AisMacControlRequest, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier,
sleY1731AisMacControlAddress }
STATUS current
DESCRIPTION
"createY1731AisMac"
::= { sleY1731AisMacNotification 1 }
sleY1731AisMacDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731AisMacControlRequest, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier,
sleY1731AisMacControlAddress }
STATUS current
DESCRIPTION
"deleteY1731AisMac"
::= { sleY1731AisMacNotification 2 }
sleY1731LckMac OBJECT IDENTIFIER ::= { sleY1731Oam 8 }
sleY1731LckMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731LckMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LckMac 1 }
sleY1731LckMacEntry OBJECT-TYPE
SYNTAX SleY1731LckMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LckMacAddress }
::= { sleY1731LckMacTable 1 }
SleY1731LckMacEntry ::=
SEQUENCE {
sleY1731LckMacAddress
OCTET STRING
}
sleY1731LckMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the unicast MAC address to send LCK"
::= { sleY1731LckMacEntry 1 }
sleY1731LckMacControl OBJECT IDENTIFIER ::= { sleY1731LckMac 2 }
sleY1731LckMacControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731LckMac(1),
deleteY1731LckMac(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LckMacControl 1 }
sleY1731LckMacControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LckMacControl 2 }
sleY1731LckMacControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LckMacControl 3 }
sleY1731LckMacControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LckMacControl 4 }
sleY1731LckMacControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LckMacControl 5 }
sleY1731LckMacControlMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's Index"
::= { sleY1731LckMacControl 6 }
sleY1731LckMacControlMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MEP Id"
::= { sleY1731LckMacControl 7 }
sleY1731LckMacControlAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the unicast MAC address to send LCK
When running deleteY1731LckMac, if this is zero-length, delete all unicast mac."
::= { sleY1731LckMacControl 8 }
sleY1731LckMacNotification OBJECT IDENTIFIER ::= { sleY1731LckMac 3 }
sleY1731LckMacCreated NOTIFICATION-TYPE
OBJECTS { sleY1731LckMacControlRequest, sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier,
sleY1731LckMacControlAddress }
STATUS current
DESCRIPTION
"createY1731LckMac"
::= { sleY1731LckMacNotification 1 }
sleY1731LckMacDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731LckMacControlRequest, sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier,
sleY1731LckMacControlAddress }
STATUS current
DESCRIPTION
"deleteY1731LckMac"
::= { sleY1731LckMacNotification 2 }
sleY1731Rmep OBJECT IDENTIFIER ::= { sleY1731Oam 9 }
sleY1731RmepTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731RmepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731Rmep 1 }
sleY1731RmepEntry OBJECT-TYPE
SYNTAX SleY1731RmepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731RmepIdentifier }
::= { sleY1731RmepTable 1 }
SleY1731RmepEntry ::=
SEQUENCE {
sleY1731RmepIdentifier
Integer32,
sleY1731RmepState
INTEGER,
sleY1731RmepFailedOkTime
TimeTicks,
sleY1731RmepMacAddress
OCTET STRING,
sleY1731RmepIfIndex
Integer32,
sleY1731RmepRdi
INTEGER,
sleY1731RmepLoc
INTEGER,
sleY1731RmepReceiveTstCount
Counter32,
sleY1731RmepReceiveTstOutOfOrder
Counter32,
sleY1731RmepReceiveTstBitError
Counter32,
sleY1731RmepReceiveTstCrcError
Counter32,
sleY1731RmepReceiveTmTstCount
Counter32,
sleY1731RmepReceiveTmTstLostId
Integer32,
sleY1731RmepLmrFrameLossNearMin
Integer32,
sleY1731RmepLmrFrameLossNearMax
Integer32,
sleY1731RmepLmrFrameLossNearSum
Integer32,
sleY1731RmepLmrFrameLossFarMin
Integer32,
sleY1731RmepLmrFrameLossFarMax
Integer32,
sleY1731RmepLmrFrameLossFarSum
Integer32,
sleY1731RmepReceive1dmCount
Counter32,
sleY1731Rmep1dmFrameDelayMin
Integer32,
sleY1731Rmep1dmFrameDelayMax
Integer32,
sleY1731Rmep1dmFrameDelayAvg
Integer32,
sleY1731Rmep1dmFrameDelayVar
Integer32,
sleY1731RmepReceiveDmrCount
Counter32,
sleY1731RmepDmrFrameDelayMin
Integer32,
sleY1731RmepDmrFrameDelayMax
Integer32,
sleY1731RmepDmrFrameDelayAvg
Integer32,
sleY1731RmepDmrFrameDelayVar
Integer32,
sleY1731RmepLmrFrameLossNearRatio
Integer32,
sleY1731RmepLmrFrameLossNearAvgRatio
Integer32,
sleY1731RmepLmrFrameLossFarRatio
Integer32,
sleY1731RmepLmrFrameLossFarAvgRatio
Integer32
}
sleY1731RmepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the remote MEP's Id"
::= { sleY1731RmepEntry 1 }
sleY1731RmepState OBJECT-TYPE
SYNTAX INTEGER
{
start(1),
failed(2),
ok(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the operational state of the remote MEP State machines"
::= { sleY1731RmepEntry 2 }
sleY1731RmepFailedOkTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time (SysUpTime) at which the Remote MEP state machine last entered either the RMEP_FAILED or RMEP_OK state."
::= { sleY1731RmepEntry 3 }
sleY1731RmepMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MAC address of the remote MEP"
::= { sleY1731RmepEntry 4 }
sleY1731RmepIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the port number of the remote MEP"
::= { sleY1731RmepEntry 5 }
sleY1731RmepRdi OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received"
::= { sleY1731RmepEntry 6 }
sleY1731RmepLoc OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Loss-of-continuity"
::= { sleY1731RmepEntry 7 }
sleY1731RmepReceiveTstCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of received TST frame"
::= { sleY1731RmepEntry 8 }
sleY1731RmepReceiveTstOutOfOrder OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of received out-of-order TST frame"
::= { sleY1731RmepEntry 9 }
sleY1731RmepReceiveTstBitError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of received bit-error TST frame"
::= { sleY1731RmepEntry 10 }
sleY1731RmepReceiveTstCrcError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of received crc-error TST frame"
::= { sleY1731RmepEntry 11 }
sleY1731RmepReceiveTmTstCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of received TST frame for the throughput-measurement"
::= { sleY1731RmepEntry 12 }
sleY1731RmepReceiveTmTstLostId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the transaction identifier of first lost TST frame for the throughput-measurement"
::= { sleY1731RmepEntry 13 }
sleY1731RmepLmrFrameLossNearMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum of single-ended near-end frame loss"
::= { sleY1731RmepEntry 14 }
sleY1731RmepLmrFrameLossNearMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum of single-ended near-end frame loss"
::= { sleY1731RmepEntry 15 }
sleY1731RmepLmrFrameLossNearSum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the sum of single-ended near-end frame loss"
::= { sleY1731RmepEntry 16 }
sleY1731RmepLmrFrameLossFarMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum of single-ended far-end frame loss"
::= { sleY1731RmepEntry 17 }
sleY1731RmepLmrFrameLossFarMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum of single-ended far-end frame loss"
::= { sleY1731RmepEntry 18 }
sleY1731RmepLmrFrameLossFarSum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the sum of single-ended far-end frame loss"
::= { sleY1731RmepEntry 19 }
sleY1731RmepReceive1dmCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of received 1DM frames for the frame delay measurement"
::= { sleY1731RmepEntry 20 }
sleY1731Rmep1dmFrameDelayMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum of one-way frame delay"
::= { sleY1731RmepEntry 21 }
sleY1731Rmep1dmFrameDelayMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum of one-way frame delay"
::= { sleY1731RmepEntry 22 }
sleY1731Rmep1dmFrameDelayAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the average of one-way frame delay"
::= { sleY1731RmepEntry 23 }
sleY1731Rmep1dmFrameDelayVar OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the variation of one-way frame delay"
::= { sleY1731RmepEntry 24 }
sleY1731RmepReceiveDmrCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of received DMR frames for the frame delay measurement"
::= { sleY1731RmepEntry 25 }
sleY1731RmepDmrFrameDelayMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum of two-way frame delay"
::= { sleY1731RmepEntry 26 }
sleY1731RmepDmrFrameDelayMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum of two-way frame delay"
::= { sleY1731RmepEntry 27 }
sleY1731RmepDmrFrameDelayAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the average of two-way frame delay"
::= { sleY1731RmepEntry 28 }
sleY1731RmepDmrFrameDelayVar OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the variation of two-way frame delay"
::= { sleY1731RmepEntry 29 }
sleY1731RmepLmrFrameLossNearRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ratio of single-ended near-end frame loss"
::= { sleY1731RmepEntry 30 }
sleY1731RmepLmrFrameLossNearAvgRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the average ratio of single-ended near-end frame loss"
::= { sleY1731RmepEntry 31 }
sleY1731RmepLmrFrameLossFarRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ratio of single-ended far-end frame loss"
::= { sleY1731RmepEntry 32 }
sleY1731RmepLmrFrameLossFarAvgRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the average ratio of single-ended far-end frame loss"
::= { sleY1731RmepEntry 33 }
sleY1731RmepControl OBJECT IDENTIFIER ::= { sleY1731Rmep 2 }
sleY1731RmepControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731Rmep(1),
deleteY1731Rmep(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731RmepControl 1 }
sleY1731RMepControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731RmepControl 2 }
sleY1731RmepControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731RmepControl 3 }
sleY1731RmepControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731RmepControl 4 }
sleY1731RmepControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731RmepControl 5 }
sleY1731RmepControlIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote MEP Id"
::= { sleY1731RmepControl 6 }
sleY1731RmepControlMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A index of MEG table"
::= { sleY1731RmepControl 7 }
sleY1731RmepControlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridge Port Index whitch the MEP is attached"
::= { sleY1731RmepControl 8 }
sleY1731RmepNotification OBJECT IDENTIFIER ::= { sleY1731Rmep 3 }
sleY1731RmepCreated NOTIFICATION-TYPE
OBJECTS { sleY1731RmepControlRequest, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier, sleY1731RmepControlMegIndex,
sleY1731RmepControlIfIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleY1731RmepNotification 1 }
sleY1731RmepDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731RmepControlRequest, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier, sleY1731RmepControlMegIndex,
sleY1731RmepControlIfIndex }
STATUS current
DESCRIPTION
"Description."
::= { sleY1731RmepNotification 2 }
sleY1731LbrMcast OBJECT IDENTIFIER ::= { sleY1731Oam 10 }
sleY1731LbrMcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731LbrMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LbrMcast 1 }
sleY1731LbrMcastEntry OBJECT-TYPE
SYNTAX SleY1731LbrMcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LbrReceiveOrder }
::= { sleY1731LbrMcastTable 1 }
SleY1731LbrMcastEntry ::=
SEQUENCE {
sleY1731LbrReceiveOrder
Integer32,
sleY1731LbrRemoteMacAddress
OCTET STRING
}
sleY1731LbrReceiveOrder OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates an index to distinguish among multiple LBRs"
::= { sleY1731LbrMcastEntry 1 }
sleY1731LbrRemoteMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MAC address of the remote MEP"
::= { sleY1731LbrMcastEntry 2 }
sleY1731LbrUcast OBJECT IDENTIFIER ::= { sleY1731Oam 11 }
sleY1731LbrUcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731LbrUcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LbrUcast 1 }
sleY1731LbrUcastEntry OBJECT-TYPE
SYNTAX SleY1731LbrUcastEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LbrTransId }
::= { sleY1731LbrUcastTable 1 }
SleY1731LbrUcastEntry ::=
SEQUENCE {
sleY1731LbrTransId
Integer32,
sleY1731LbrRoundTripTime
Integer32
}
sleY1731LbrTransId OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the transaction identifier of LBR message."
::= { sleY1731LbrUcastEntry 1 }
sleY1731LbrRoundTripTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the round-trip time of LBR message."
::= { sleY1731LbrUcastEntry 2 }
sleY1731Ltr OBJECT IDENTIFIER ::= { sleY1731Oam 12 }
sleY1731LtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731LtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731Ltr 1 }
sleY1731LtrEntry OBJECT-TYPE
SYNTAX SleY1731LtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731LtrSeqNumber, sleY1731LtrReceiveOrder }
::= { sleY1731LtrTable 1 }
SleY1731LtrEntry ::=
SEQUENCE {
sleY1731LtrSeqNumber
Integer32,
sleY1731LtrReceiveOrder
Integer32,
sleY1731LtrRoundTripTime
Integer32,
sleY1731LtrTtl
Integer32,
sleY1731LtrForwarded
INTEGER,
sleY1731LtrTerminalMep
INTEGER,
sleY1731LtrLastEgressIdentifier
OCTET STRING,
sleY1731LtrNextEgressIdentifier
OCTET STRING,
sleY1731LtrRelay
INTEGER,
sleY1731LtrIngress
INTEGER,
sleY1731LtrIngressMac
OCTET STRING,
sleY1731LtrIngressPort
Integer32,
sleY1731LtrEgress
INTEGER,
sleY1731LtrEgressMac
OCTET STRING,
sleY1731LtrEgressPort
Integer32
}
sleY1731LtrSeqNumber OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the LTM Transaction Identifier returned from a previous Transmit Linktrace Message command,
indicating the LTM entry to which the LTR entries will be attached
"
::= { sleY1731LtrEntry 1 }
sleY1731LtrReceiveOrder OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates an index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value"
::= { sleY1731LtrEntry 2 }
sleY1731LtrRoundTripTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the round-trip time of LTR message."
::= { sleY1731LtrEntry 3 }
sleY1731LtrTtl OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates TTL field value for a returned LTR."
::= { sleY1731LtrEntry 4 }
sleY1731LtrForwarded OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field."
::= { sleY1731LtrEntry 5 }
sleY1731LtrTerminalMep OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates a boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field. "
::= { sleY1731LtrEntry 6 }
sleY1731LtrLastEgressIdentifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the MEP Linktrace Initiator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response"
::= { sleY1731LtrEntry 7 }
sleY1731LtrNextEgressIdentifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop."
::= { sleY1731LtrEntry 8 }
sleY1731LtrRelay OBJECT-TYPE
SYNTAX INTEGER
{
rlyHit(1),
rlyFDB(2),
rlyMPDB(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value returned in the Ingress Action Field of the LTM"
::= { sleY1731LtrEntry 9 }
sleY1731LtrIngress OBJECT-TYPE
SYNTAX INTEGER
{
ingNoTlv(0),
ingOK(1),
ingDown(2),
ingBlocked(3),
ingVid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value returned in the Ingress Action Field of the LTM"
::= { sleY1731LtrEntry 10 }
sleY1731LtrIngressMac OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates MAC address returned in the ingress MAC address field."
::= { sleY1731LtrEntry 11 }
sleY1731LtrIngressPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Ingress Port ID"
::= { sleY1731LtrEntry 12 }
sleY1731LtrEgress OBJECT-TYPE
SYNTAX INTEGER
{
egrNoTlv(0),
egrOK(1),
egrDown(2),
egrBlocked(3),
egrVid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value returned in the Egress Action Field of the LTM"
::= { sleY1731LtrEntry 13 }
sleY1731LtrEgressMac OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates MAC address returned in the egress MAC address field."
::= { sleY1731LtrEntry 14 }
sleY1731LtrEgressPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Egress Port ID"
::= { sleY1731LtrEntry 15 }
sleY1731ConfigError OBJECT IDENTIFIER ::= { sleY1731Oam 13 }
sleY1731ConfigErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731ConfigErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731ConfigError 1 }
sleY1731ConfigErrorEntry OBJECT-TYPE
SYNTAX SleY1731ConfigErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731ConfigErrorVid, sleY1731ConfigErrorIfIndex }
::= { sleY1731ConfigErrorTable 1 }
SleY1731ConfigErrorEntry ::=
SEQUENCE {
sleY1731ConfigErrorVid
Integer32,
sleY1731ConfigErrorIfIndex
Integer32,
sleY1731ConfigErrorType
BITS
}
sleY1731ConfigErrorVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Configuration Error VLAN Identifier"
::= { sleY1731ConfigErrorEntry 1 }
sleY1731ConfigErrorIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Configuration Error Port Number"
::= { sleY1731ConfigErrorEntry 2 }
sleY1731ConfigErrorType OBJECT-TYPE
SYNTAX BITS
{
y1731leak(0),
conflictingVids(1),
excessiveLevels(2),
overlappedLevels(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Configuration Error Type"
::= { sleY1731ConfigErrorEntry 3 }
sleY1731MipCcdb OBJECT IDENTIFIER ::= { sleY1731Oam 14 }
sleY1731MipCcdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731MipCcdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731MipCcdb 1 }
sleY1731MipCcdbEntry OBJECT-TYPE
SYNTAX SleY1731MipCcdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MipCcdbIndex }
::= { sleY1731MipCcdbTable 1 }
SleY1731MipCcdbEntry ::=
SEQUENCE {
sleY1731MipCcdbIndex
Integer32,
sleY1731MipCcdbVlanId
Integer32,
sleY1731MipCcdbMacAddr
OCTET STRING,
sleY1731MipCcdbPort
Integer32,
sleY1731MipCcdbKeepTime
TimeTicks
}
sleY1731MipCcdbIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MIP CCDB's Index"
::= { sleY1731MipCcdbEntry 1 }
sleY1731MipCcdbVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN Id"
::= { sleY1731MipCcdbEntry 2 }
sleY1731MipCcdbMacAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates MAC address of the remote MEP"
::= { sleY1731MipCcdbEntry 3 }
sleY1731MipCcdbPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Port number that the CCM output"
::= { sleY1731MipCcdbEntry 4 }
sleY1731MipCcdbKeepTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates an up-date time of a entry"
::= { sleY1731MipCcdbEntry 5 }
sleY1731UplinkRedundancy OBJECT IDENTIFIER ::= { sleY1731Oam 15 }
sleY1731URTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731UREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Y1731 Uplink-redundancy information table."
::= { sleY1731UplinkRedundancy 1 }
sleY1731UREntry OBJECT-TYPE
SYNTAX SleY1731UREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"key: sleY1731URMegIndex"
INDEX { sleY1731URMegIndex }
::= { sleY1731URTable 1 }
SleY1731UREntry ::=
SEQUENCE {
sleY1731URMegIndex
INTEGER,
sleY1731URMegName
OCTET STRING,
sleY1731URDedicatedVlan
INTEGER,
sleY1731UREnableStatus
INTEGER,
sleY1731URConnectivityCheckMeg
OCTET STRING,
sleY1731URPrimaryMepId
INTEGER,
sleY1731URSecondaryMepId
INTEGER,
sleY1731URControlVlan
INTEGER,
sleY1731URNodeConf
INTEGER,
sleY1731URNodeConfPortNum
INTEGER,
sleY1731URNodeConfPortStatus
INTEGER,
sleY1731URNonRevertive
INTEGER,
sleY1731URTrustMemberCount
INTEGER,
sleY1731URWaitToRestore
INTEGER,
sleY1731URForceSwitch
INTEGER,
sleY1731URSFCondition
INTEGER,
sleY1731URTrafficVlan
OCTET STRING,
sleY1731URState
INTEGER,
sleY1731URManualSwitch
INTEGER
}
sleY1731URMegIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MEG index."
::= { sleY1731UREntry 1 }
sleY1731URMegName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MEG name."
::= { sleY1731UREntry 2 }
sleY1731URDedicatedVlan OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates R-APS node to use dedicated-VLAN
disable : all VLAN
enable : one VLAN"
::= { sleY1731UREntry 3 }
sleY1731UREnableStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Uplink-redundancy feature
0 : disable
1 : enable"
::= { sleY1731UREntry 4 }
sleY1731URConnectivityCheckMeg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the connectivity check - MEG name."
::= { sleY1731UREntry 5 }
sleY1731URPrimaryMepId OBJECT-TYPE
SYNTAX INTEGER (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the connectivity check - primary MEP's ID"
::= { sleY1731UREntry 6 }
sleY1731URSecondaryMepId OBJECT-TYPE
SYNTAX INTEGER (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the connectivity check - secondary MEP's ID"
::= { sleY1731UREntry 7 }
sleY1731URControlVlan OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the control VLAN"
::= { sleY1731UREntry 8 }
sleY1731URNodeConf OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
master(1),
slave(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the (master/slave) node of the redundancy"
::= { sleY1731UREntry 9 }
sleY1731URNodeConfPortNum OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number"
::= { sleY1731UREntry 10 }
sleY1731URNodeConfPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
disabled(1),
forwarding(2),
blocking(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The uplink port status
0: none
1: disabled
2: forwarding
3: blocking"
::= { sleY1731UREntry 11 }
sleY1731URNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
ture(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The non-revertive mode"
::= { sleY1731UREntry 12 }
sleY1731URTrustMemberCount OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the trust LOC count at link-aggregation port"
::= { sleY1731UREntry 13 }
sleY1731URWaitToRestore OBJECT-TYPE
SYNTAX INTEGER (5..720)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time ( 5 - 720 )"
::= { sleY1731UREntry 14 }
sleY1731URForceSwitch OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The forced-switch of uplink port
"
::= { sleY1731UREntry 15 }
sleY1731URSFCondition OBJECT-TYPE
SYNTAX INTEGER
{
loc(0),
locRdi(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sf condition
"
::= { sleY1731UREntry 16 }
sleY1731URTrafficVlan OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Traffic vlan.
"
::= { sleY1731UREntry 17 }
sleY1731URState OBJECT-TYPE
SYNTAX INTEGER
{
unReady(0),
ready(1),
active(2),
standby(3),
preActive(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The uplink redundancy node state
none(0)
unReady(1)
ready(2)
active(3)
standby(4)
preActive(5)"
::= { sleY1731UREntry 18 }
sleY1731URManualSwitch OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manual-switch of uplink port
"
::= { sleY1731UREntry 19 }
sleY1731URControl OBJECT IDENTIFIER ::= { sleY1731UplinkRedundancy 2 }
sleY1731URControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setDedicatedVlan(1),
setEnableStatus(2),
setCCPrimaryMepId(3),
clearCCPrimaryMepId(4),
setCCSecondaryMepId(5),
clearCCSecondaryMepId(6),
setControlVlan(7),
clearControlVlan(8),
setNodeConfiguration(9),
clearNodeConfiguration(10),
setNonRevertive(11),
setTrustMemberCount(12),
clearTrustMemberCount(13),
setWaitToRestore(14),
clearWaitToRestore(15),
setForceSwitch(16),
setManualSwitch(17),
setSFCondition(18),
setTrafficVlan(19),
clearTrafficVlan(20)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute identifies the control commands.
updateAlarmList:
the NE updates entries of alarms in the sleAlarmListTable
after having changed alarm severities of alarms
(due to change profile pointers in
managed entities or after modification of alarm severities
in profiles). This command should be applied once after having
finisled modifications of severties.
modifyAlarmSeverity:
modifies the severity of an alarm in specific profile.
createAlarmSeverityProfile:
creates a new profile with default severities.
The severities then have to be modified with command changeAlarmSeverity.
deleteAlarmSeverityProfile:
deletes a profile. Profile 1 is not allowed to be deleted.
Notifications : none "
::= { sleY1731URControl 1 }
sleY1731URControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of a control request. "
::= { sleY1731URControl 2 }
sleY1731URControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleY1731URControl 3 }
sleY1731URControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleY1731URControl 4 }
sleY1731URControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The result of the last user command. "
::= { sleY1731URControl 5 }
sleY1731URControlMegIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MEG index."
::= { sleY1731URControl 6 }
sleY1731URControlMegName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MEG name."
::= { sleY1731URControl 7 }
sleY1731URControlDedicatedVlan OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates R-APS node to use dedicated-VLAN
disable : all VLAN
enable : one VLAN"
::= { sleY1731URControl 8 }
sleY1731URControlEnableStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Uplink-redundancy feature
0 : disable
1 : enable"
::= { sleY1731URControl 9 }
sleY1731URControlConnectivityCheckMeg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the connectivity check - MEG name."
::= { sleY1731URControl 10 }
sleY1731URControlPrimaryMepId OBJECT-TYPE
SYNTAX INTEGER (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the connectivity check - primary MEP's ID"
::= { sleY1731URControl 11 }
sleY1731URControlSecondaryMepId OBJECT-TYPE
SYNTAX INTEGER (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the connectivity check - secondary MEP's ID"
::= { sleY1731URControl 12 }
sleY1731URControlControlVlan OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the control VLAN"
::= { sleY1731URControl 13 }
sleY1731URControlNodeConf OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
master(1),
slave(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the (master/slave) node of the redundancy"
::= { sleY1731URControl 14 }
sleY1731URControlNodeConfPortNum OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number"
::= { sleY1731URControl 15 }
sleY1731URControlNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
ture(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The non-revertive mode"
::= { sleY1731URControl 16 }
sleY1731URControlTrustMemberCount OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the trust LOC count at link-aggregation port"
::= { sleY1731URControl 17 }
sleY1731URControlWaitToRestore OBJECT-TYPE
SYNTAX INTEGER (5..720)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time ( 5 - 720 )"
::= { sleY1731URControl 18 }
sleY1731URControlForceSwitch OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The forced-switch of uplink port"
::= { sleY1731URControl 19 }
sleY1731URControlSFCondition OBJECT-TYPE
SYNTAX INTEGER
{
loc(0),
locRdi(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The sf condition"
::= { sleY1731URControl 20 }
sleY1731URControlTrafficVlan OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Traffic vlan"
::= { sleY1731URControl 21 }
sleY1731URControlManualSwitch OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manual-switch of uplink port"
::= { sleY1731URControl 22 }
sleY1731URNotification OBJECT IDENTIFIER ::= { sleY1731UplinkRedundancy 3 }
sleY1731URDedicatedVlanChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlDedicatedVlan }
STATUS current
DESCRIPTION
"setY1731URDedicatedVlan"
::= { sleY1731URNotification 1 }
sleY1731UREnableStatusChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlEnableStatus }
STATUS current
DESCRIPTION
"setY1731UREnableStatus"
::= { sleY1731URNotification 2 }
sleY1731URCCPrimaryMepIdChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlConnectivityCheckMeg, sleY1731URControlPrimaryMepId }
STATUS current
DESCRIPTION
"setY1731URCCPrimaryMepId"
::= { sleY1731URNotification 3 }
sleY1731URCCPrimaryMepIdCleared NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
}
STATUS current
DESCRIPTION
"delY1731URCCPrimaryMepId"
::= { sleY1731URNotification 4 }
sleY1731URCCSecondaryMepIdChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlConnectivityCheckMeg, sleY1731URControlSecondaryMepId }
STATUS current
DESCRIPTION
"setY1731URCCSecondaryMepId"
::= { sleY1731URNotification 5 }
sleY1731URCCSecondaryMepIdCleared NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
}
STATUS current
DESCRIPTION
"delY1731URCCSecondaryMepId"
::= { sleY1731URNotification 6 }
sleY1731URControlVlanChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlControlVlan }
STATUS current
DESCRIPTION
"setY1731URControlVlan"
::= { sleY1731URNotification 7 }
sleY1731URControlVlanCleared NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
}
STATUS current
DESCRIPTION
"delY1731URControlVlan"
::= { sleY1731URNotification 8 }
sleY1731URNodeConfChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlNodeConf, sleY1731URControlNodeConfPortNum }
STATUS current
DESCRIPTION
"setY1731URNodeConf"
::= { sleY1731URNotification 9 }
sleY1731URNodeConfCleared NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlNodeConf }
STATUS current
DESCRIPTION
"delY1731URNodeConf"
::= { sleY1731URNotification 10 }
sleY1731URNonRevertiveChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlNonRevertive }
STATUS current
DESCRIPTION
"setY1731URNonRevertive"
::= { sleY1731URNotification 11 }
sleY1731URTrustMemberCountChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlTrustMemberCount }
STATUS current
DESCRIPTION
"setY1731URTrustMemberCount"
::= { sleY1731URNotification 12 }
sleY1731URTrustMemberCountCleared NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
}
STATUS current
DESCRIPTION
"delY1731URTrustMemberCount"
::= { sleY1731URNotification 13 }
sleY1731URWaitToRestoreChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlWaitToRestore }
STATUS current
DESCRIPTION
"setY1731URWaitToRestore"
::= { sleY1731URNotification 14 }
sleY1731URWaitToRestoreCleared NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
}
STATUS current
DESCRIPTION
"delY1731URWaitToRestore"
::= { sleY1731URNotification 15 }
sleY1731URForceSwitchChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlForceSwitch }
STATUS current
DESCRIPTION
"setForceSwitch"
::= { sleY1731URNotification 16 }
sleY1731URManualSwitchChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlManualSwitch }
STATUS current
DESCRIPTION
"setManualSwitch"
::= { sleY1731URNotification 17 }
sleY1731URSFConditionChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName
}
STATUS current
DESCRIPTION
"setSFCondition"
::= { sleY1731URNotification 18 }
sleY1731URTrafficVlanChanged NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex, sleY1731URControlMegName,
sleY1731URControlTrafficVlan }
STATUS current
DESCRIPTION
"setTrafficVlan."
::= { sleY1731URNotification 19 }
sleY1731URTrafficVlanCleared NOTIFICATION-TYPE
OBJECTS { sleY1731URControlRequest, sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegIndex }
STATUS current
DESCRIPTION
"clearTrafficVlan."
::= { sleY1731URNotification 20 }
sleY1731LocRefMep OBJECT IDENTIFIER ::= { sleY1731Oam 16 }
sleY1731LocRefMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleY1731LocRefMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LocRefMep 1 }
sleY1731LocRefMepEntry OBJECT-TYPE
SYNTAX SleY1731LocRefMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleY1731MegIndex, sleY1731MepIdentifier, sleY1731CcMacAddress }
::= { sleY1731LocRefMepTable 1 }
SleY1731LocRefMepEntry ::=
SEQUENCE {
sleY1731LRMepIndex
Integer32,
sleY1731LRMepDMegIndex
Integer32,
sleY1731LRMepDMepIdentifier
Integer32,
sleY1731LRMepDRmepIdentifier
Integer32
}
sleY1731LRMepIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the index of the LOC reference MEP."
::= { sleY1731LocRefMepEntry 1 }
sleY1731LRMepDMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MEG's Index of Down MEP"
::= { sleY1731LocRefMepEntry 2 }
sleY1731LRMepDMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the identifier of Down MEP."
::= { sleY1731LocRefMepEntry 3 }
sleY1731LRMepDRmepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the identifier of Remote MEP."
::= { sleY1731LocRefMepEntry 4 }
sleY1731LocRefMepControl OBJECT IDENTIFIER ::= { sleY1731LocRefMep 2 }
sleY1731LRMepControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createY1731LocRefMep(1),
deleteY1731LocRefMep(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LocRefMepControl 1 }
sleY1731LRMepControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LocRefMepControl 2 }
sleY1731LRMepControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LocRefMepControl 3 }
sleY1731LRMepControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleY1731LocRefMepControl 4 }
sleY1731LRMepControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the last command."
::= { sleY1731LocRefMepControl 5 }
sleY1731LRMepControlMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's Index of Up MEP."
::= { sleY1731LocRefMepControl 6 }
sleY1731LRMepControlMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the identifier of Up MEP."
::= { sleY1731LocRefMepControl 7 }
sleY1731LRMepControlRmepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the identifier of RMEP id of Up MEP."
::= { sleY1731LocRefMepControl 8 }
sleY1731LRMepControlDMegIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MEG's Index of Down MEP."
::= { sleY1731LocRefMepControl 9 }
sleY1731LRMepControlDMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the identifier of Down MEP."
::= { sleY1731LocRefMepControl 10 }
sleY1731LRMepControlDRmepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the identifier of RMEP id of Down MEP."
::= { sleY1731LocRefMepControl 11 }
sleY1731LocRefMepNotification OBJECT IDENTIFIER ::= { sleY1731LocRefMep 3 }
sleY1731LRMepCreated NOTIFICATION-TYPE
OBJECTS { sleY1731LRMepControlRequest, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult, sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier,
sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier, sleY1731LRMepControlDRmepIdentifier }
STATUS current
DESCRIPTION
"createY1731LocRefMep"
::= { sleY1731LocRefMepNotification 1 }
sleY1731LRMEPDeleted NOTIFICATION-TYPE
OBJECTS { sleY1731LRMepControlRequest, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult, sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier,
sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier, sleY1731LRMepControlDRmepIdentifier }
STATUS current
DESCRIPTION
"deleteY1731LocRefMep"
::= { sleY1731LocRefMepNotification 3 }
sleCfmOam OBJECT IDENTIFIER ::= { sleFaultMgmt 13 }
sleCfmBase OBJECT IDENTIFIER ::= { sleCfmOam 1 }
sleCfmBaseGroup OBJECT IDENTIFIER ::= { sleCfmBase 1 }
sleCfmEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Ddisables IEEE 802.1ag CFM OAM function"
::= { sleCfmBaseGroup 1 }
sleCfmLtrCacheHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time that cache entries will be retained"
::= { sleCfmBaseGroup 2 }
sleCfmLtrCacheSize OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of entries in the traceroute cache"
::= { sleCfmBaseGroup 3 }
sleCfmSnmpServerTraps OBJECT-TYPE
SYNTAX BITS
{
rdiccm(0),
macstatus(1),
remoteccm(2),
errorccm(3),
xconccm(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the SNMP traps"
::= { sleCfmBaseGroup 4 }
sleCfmXcheckStartDelay OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the delay before the cross-check is started"
::= { sleCfmBaseGroup 5 }
sleCfmBaseControl OBJECT IDENTIFIER ::= { sleCfmBase 2 }
sleCfmBaseControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setCfmEnable(1),
setCfmLtrCacheProfile(2),
setCfmSnmpProfile(3),
setCfmXcheckProfile(4),
destroyMipCcdb(5),
destroyLtrCache(6),
createCfmTrunkPort(7),
deleteCfmTrunkPort(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This attribute identifies the control commands.
updateAlarmList:
the NE updates entries of alarms in the sleAlarmListTable
after having changed alarm severities of alarms
(due to change profile pointers in
managed entities or after modification of alarm severities
in profiles). This command should be applied once after having
finisled modifications of severties.
modifyAlarmSeverity:
modifies the severity of an alarm in specific profile.
createAlarmSeverityProfile:
creates a new profile with default severities.
The severities then have to be modified with command changeAlarmSeverity.
deleteAlarmSeverityProfile:
deletes a profile. Profile 1 is not allowed to be deleted.
Notifications : none "
::= { sleCfmBaseControl 1 }
sleCfmBaseControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleCfmBaseControl 2 }
sleCfmBaseControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleCfmBaseControl 3 }
sleCfmBaseControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleCfmBaseControl 4 }
sleCfmBaseControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleCfmBaseControl 5 }
sleCfmBaseControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Ddisables IEEE 802.1ag CFM OAM function"
::= { sleCfmBaseControl 6 }
sleCfmBaseControlLtrCacheHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the time that cache entries will be retained"
::= { sleCfmBaseControl 7 }
sleCfmBaseControlLtrCacheSize OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the number of entries in the traceroute cache"
::= { sleCfmBaseControl 8 }
sleCfmBaseControlSnmpServerTraps OBJECT-TYPE
SYNTAX BITS
{
ridccm(0),
macstatus(1),
remoteccm(2),
errorccm(3),
xconccm(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the SNMP traps"
::= { sleCfmBaseControl 9 }
sleCfmBaseControlXcheckStartDelay OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the delay before the cross-check is started"
::= { sleCfmBaseControl 10 }
sleCfmBaseControlTrunkIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk Port Index"
::= { sleCfmBaseControl 11 }
sleCfmBaseControlTrunkMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"trunk port md name."
::= { sleCfmBaseControl 12 }
sleCfmBaseControlTrunkMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MA's VID"
::= { sleCfmBaseControl 13 }
sleCfmBaseNotification OBJECT IDENTIFIER ::= { sleCfmBase 3 }
sleCfmEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlEnable }
STATUS current
DESCRIPTION
"setCfmEnable"
::= { sleCfmBaseNotification 1 }
sleCfmLtrCacheProfileChanged NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlLtrCacheHoldTime, sleCfmBaseControlLtrCacheSize
}
STATUS current
DESCRIPTION
"setCfmLtrCacheProfile"
::= { sleCfmBaseNotification 2 }
sleCfmSnmpServerTrapsChanged NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlSnmpServerTraps }
STATUS current
DESCRIPTION
"setCfmSnmpProfile"
::= { sleCfmBaseNotification 3 }
sleCfmXcheckStartDelayChanged NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlXcheckStartDelay }
STATUS current
DESCRIPTION
"setCfmXcheckProfile"
::= { sleCfmBaseNotification 4 }
sleCfmMipCcdbDestroyed NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlRequest, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult }
STATUS current
DESCRIPTION
"destroyMipCcdb"
::= { sleCfmBaseNotification 5 }
sleCfmLtrCacheDestroyed NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlRequest, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult }
STATUS current
DESCRIPTION
"destroyLtrCache"
::= { sleCfmBaseNotification 6 }
sleCfmTrunkPortCreated NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlTrunkIndex, sleCfmBaseControlTrunkMdName,
sleCfmBaseControlTrunkMaVid }
STATUS current
DESCRIPTION
"createCfmTrunkPort"
::= { sleCfmBaseNotification 7 }
sleCfmTrunkPortDeleted NOTIFICATION-TYPE
OBJECTS { sleCfmBaseControlStatus, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult, sleCfmBaseControlTrunkIndex }
STATUS current
DESCRIPTION
"deleteCfmTrunkPort"
::= { sleCfmBaseNotification 8 }
sleCfmTrunkTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmTrunkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmBase 4 }
sleCfmTrunkEntry OBJECT-TYPE
SYNTAX SleCfmTrunkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmTrunkIndex }
::= { sleCfmTrunkTable 1 }
SleCfmTrunkEntry ::=
SEQUENCE {
sleCfmTrunkIndex
INTEGER,
sleCfmTrunkMdName
OCTET STRING,
sleCfmTrunkMaVid
INTEGER
}
sleCfmTrunkIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"trunk port index."
::= { sleCfmTrunkEntry 1 }
sleCfmTrunkMdName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"trunk port md name."
::= { sleCfmTrunkEntry 2 }
sleCfmTrunkMaVid OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MA's VID"
::= { sleCfmTrunkEntry 3 }
sleCfmMd OBJECT IDENTIFIER ::= { sleCfmOam 2 }
sleCfmMdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMd 1 }
sleCfmMdEntry OBJECT-TYPE
SYNTAX SleCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMdIndex }
::= { sleCfmMdTable 1 }
SleCfmMdEntry ::=
SEQUENCE {
sleCfmMdIndex
Integer32,
sleCfmMdName
OCTET STRING,
sleCfmMdLevel
Integer32,
sleCfmMdMepEnable
INTEGER,
sleCfmMdCcEnable
INTEGER,
sleCfmMdCcInterval
Integer32,
sleCfmMdCcPriority
Integer32,
sleCfmMdCcLossThreshold
Integer32,
sleCfmMdCcHoldTime
Integer32,
sleCfmMdFaultPriority
INTEGER,
sleCfmMdFaultKeepTime
Integer32,
sleCfmMdFaultClearTime
Integer32,
sleCfmMdXcheckEnable
INTEGER
}
sleCfmMdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MD's Index"
::= { sleCfmMdEntry 1 }
sleCfmMdName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MD's name"
::= { sleCfmMdEntry 2 }
sleCfmMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MD's level"
::= { sleCfmMdEntry 3 }
sleCfmMdMepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables CFM OAM for MEPs"
::= { sleCfmMdEntry 4 }
sleCfmMdCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables MEPs to send Continuity Check messages"
::= { sleCfmMdEntry 5 }
sleCfmMdCcInterval OBJECT-TYPE
SYNTAX Integer32 (2..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interval between CCM transmissions"
::= { sleCfmMdEntry 6 }
sleCfmMdCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the CCM Priority"
::= { sleCfmMdEntry 7 }
sleCfmMdCcLossThreshold OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
::= { sleCfmMdEntry 8 }
sleCfmMdCcHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the time that data of a missing MEP is kept"
::= { sleCfmMdEntry 9 }
sleCfmMdFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdiccm(1),
macstatus(2),
remoteccm(3),
errorccm(4),
xconccm(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the lowest priority for fault alarm"
::= { sleCfmMdEntry 10 }
sleCfmMdFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the keep time for the fault alarm"
::= { sleCfmMdEntry 11 }
sleCfmMdFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the clear time for the fault alarm"
::= { sleCfmMdEntry 12 }
sleCfmMdXcheckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables CFM cross-check for a specific MEG"
::= { sleCfmMdEntry 13 }
sleCfmMdControl OBJECT IDENTIFIER ::= { sleCfmMd 2 }
sleCfmMdControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmMd(1),
deleteCfmMd(2),
setCfmMdMepEnable(3),
setCfmMdCcEnable(4),
setCfmMdCcProfile(5),
setCfmMdFaultProfile(6),
setCfmMdXcheckEnable(7),
destroyCfmMdError(8),
destroyCfmMdRmep(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMdControl 1 }
sleCfmMdControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMdControl 2 }
sleCfmMdControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMdControl 3 }
sleCfmMdControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMdControl 4 }
sleCfmMdControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMdControl 5 }
sleCfmMdControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MD's Index"
::= { sleCfmMdControl 6 }
sleCfmMdControlName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MD's name"
::= { sleCfmMdControl 7 }
sleCfmMdControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MD's level"
::= { sleCfmMdControl 8 }
sleCfmMdControlMepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables CFM OAM for MEPs"
::= { sleCfmMdControl 9 }
sleCfmMdControlCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables MEPs to send Continuity Check messages"
::= { sleCfmMdControl 10 }
sleCfmMdControlCcInterval OBJECT-TYPE
SYNTAX Integer32 (2..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval between CCM transmissions"
::= { sleCfmMdControl 11 }
sleCfmMdControlCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the CCM Priority"
::= { sleCfmMdControl 12 }
sleCfmMdControlCcLossThreshold OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
::= { sleCfmMdControl 13 }
sleCfmMdControlCcHoldTime OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the time that data of a missing MEP is kept"
::= { sleCfmMdControl 14 }
sleCfmMdControlFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdiccm(1),
macstatus(2),
remoteccm(3),
errorccm(4),
xconccm(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the lowest priority for fault alarm"
::= { sleCfmMdControl 15 }
sleCfmMdControlFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the keep time for the fault alarm"
::= { sleCfmMdControl 16 }
sleCfmMdControlFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the clear time for the fault alarm"
::= { sleCfmMdControl 17 }
sleCfmMdControlXcheckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables CFM cross-check for a specific MEG"
::= { sleCfmMdControl 18 }
sleCfmMdNotification OBJECT IDENTIFIER ::= { sleCfmMd 3 }
sleCfmMdCreated NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlName, sleCfmMdControlLevel
}
STATUS current
DESCRIPTION
"createCfmMd"
::= { sleCfmMdNotification 1 }
sleCfmMdDeleted NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlName }
STATUS current
DESCRIPTION
"deleteCfmMd"
::= { sleCfmMdNotification 2 }
sleCfmMdMepEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlMepEnable
}
STATUS current
DESCRIPTION
"setCfmMepEnable"
::= { sleCfmMdNotification 3 }
sleCfmMdCcEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlCcEnable
}
STATUS current
DESCRIPTION
"setCfmMdCcEnable"
::= { sleCfmMdNotification 4 }
sleCfmMdCcProfileChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlCcInterval,
sleCfmMdControlCcPriority, sleCfmMdControlCcLossThreshold, sleCfmMdControlCcHoldTime }
STATUS current
DESCRIPTION
"setCfmMdCcProfile"
::= { sleCfmMdNotification 5 }
sleCfmMdFaultProfileChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlFaultPriority,
sleCfmMdControlFaultKeepTime, sleCfmMdControlFaultClearTime }
STATUS current
DESCRIPTION
"setCfmMdFaultProfile"
::= { sleCfmMdNotification 6 }
sleCfmMdXcheckEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex, sleCfmMdControlXcheckEnable
}
STATUS current
DESCRIPTION
"setCfmMdXcheckEnable"
::= { sleCfmMdNotification 7 }
sleCfmMdErrorDestoryed NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex }
STATUS current
DESCRIPTION
"destroyCfmMdError"
::= { sleCfmMdNotification 8 }
sleCfmMdRmepDestoryed NOTIFICATION-TYPE
OBJECTS { sleCfmMdControlRequest, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex }
STATUS current
DESCRIPTION
"destroyCfmMdRmep"
::= { sleCfmMdNotification 9 }
sleCfmMa OBJECT IDENTIFIER ::= { sleCfmOam 3 }
sleCfmMaTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMa 1 }
sleCfmMaEntry OBJECT-TYPE
SYNTAX SleCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMdIndex, sleCfmMaIndex }
::= { sleCfmMaTable 1 }
SleCfmMaEntry ::=
SEQUENCE {
sleCfmMaIndex
Integer32,
sleCfmMaName
OCTET STRING,
sleCfmMaVid
Integer32,
sleCfmMaMepEnable
INTEGER,
sleCfmMaCcEnable
INTEGER,
sleCfmMaCcInterval
Integer32,
sleCfmMaCcPriority
Integer32,
sleCfmMaCcLossThreshold
Integer32,
sleCfmMaCcFaultPriority
INTEGER,
sleCfmMaCcFaultKeepTime
Integer32,
sleCfmMaCcFaultClearTime
Integer32,
sleCfmMaXcheckEnable
INTEGER
}
sleCfmMaIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MA's Index"
::= { sleCfmMaEntry 1 }
sleCfmMaName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MA's name"
::= { sleCfmMaEntry 2 }
sleCfmMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MA's VID"
::= { sleCfmMaEntry 3 }
sleCfmMaMepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables CFM OAM for MEPs"
::= { sleCfmMaEntry 4 }
sleCfmMaCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables MEPs to send Continuity Check messages"
::= { sleCfmMaEntry 5 }
sleCfmMaCcInterval OBJECT-TYPE
SYNTAX Integer32 (2..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interval between CCM transmissions"
::= { sleCfmMaEntry 6 }
sleCfmMaCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the CCM Priority"
::= { sleCfmMaEntry 7 }
sleCfmMaCcLossThreshold OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
::= { sleCfmMaEntry 8 }
sleCfmMaCcFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdiccm(1),
macstatus(2),
remoteccm(3),
errorccm(4),
xconccm(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the lowest priority for fault alarm"
::= { sleCfmMaEntry 9 }
sleCfmMaCcFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the keep time for the fault alarm"
::= { sleCfmMaEntry 10 }
sleCfmMaCcFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the clear time for the fault alarm"
::= { sleCfmMaEntry 11 }
sleCfmMaXcheckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables CFM cross-check for a specific MEG"
::= { sleCfmMaEntry 12 }
sleCfmMaControl OBJECT IDENTIFIER ::= { sleCfmMa 2 }
sleCfmMaControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmMa(1),
deleteCfmMa(2),
setCfmMaMepEnable(3),
setCfmMaCcEnable(4),
setCfmMaCcProfile(5),
setCfmMaFaultProfile(6),
setCfmMaXcheckEnable(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMaControl 1 }
sleCfmMaControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMaControl 2 }
sleCfmMaControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMaControl 3 }
sleCfmMaControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMaControl 4 }
sleCfmMaControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMaControl 5 }
sleCfmMaControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MA's Index"
::= { sleCfmMaControl 6 }
sleCfmMaControlName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MA's name."
::= { sleCfmMaControl 7 }
sleCfmMaControlVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MA's VID"
::= { sleCfmMaControl 8 }
sleCfmMaControlMdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MD's Index"
::= { sleCfmMaControl 9 }
sleCfmMaControlMepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables CFM OAM for MEPs"
::= { sleCfmMaControl 10 }
sleCfmMaControlCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables MEPs to send Continuity Check messages"
::= { sleCfmMaControl 11 }
sleCfmMaControlCcInterval OBJECT-TYPE
SYNTAX Integer32 (2..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval between CCM transmissions"
::= { sleCfmMaControl 12 }
sleCfmMaControlCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the CCM Priority"
::= { sleCfmMaControl 13 }
sleCfmMaControlCcLossThreshold OBJECT-TYPE
SYNTAX Integer32 (2..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the minimum number of CCMs that can be missed before declaring that a MEP is down"
::= { sleCfmMaControl 14 }
sleCfmMaControlFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdiccm(1),
macstatus(2),
remoteccm(3),
errorccm(4),
xconccm(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the lowest priority for fault alarm"
::= { sleCfmMaControl 15 }
sleCfmMaControlFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the keep time for the fault alarm"
::= { sleCfmMaControl 16 }
sleCfmMaControlFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the clear time for the fault alarm"
::= { sleCfmMaControl 17 }
sleCfmMaControlXcheckEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/Disables CFM cross-check for a specific MEG"
::= { sleCfmMaControl 18 }
sleCfmMaNotification OBJECT IDENTIFIER ::= { sleCfmMa 3 }
sleCfmMaCreated NOTIFICATION-TYPE
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlName, sleCfmMaControlMdIndex,
sleCfmMaControlVid }
STATUS current
DESCRIPTION
"createCfmMa"
::= { sleCfmMaNotification 1 }
sleCfmMaDeleted NOTIFICATION-TYPE
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlName, sleCfmMaControlMdIndex
}
STATUS current
DESCRIPTION
"deleteCfmMa"
::= { sleCfmMaNotification 2 }
sleCfmMaMepEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
sleCfmMaControlMepEnable }
STATUS current
DESCRIPTION
"setCfmMaMepEnable"
::= { sleCfmMaNotification 3 }
sleCfmMaCcEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
sleCfmMaControlCcEnable }
STATUS current
DESCRIPTION
"setCfmMaCcEnable"
::= { sleCfmMaNotification 4 }
sleCfmMaCcProfileChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
sleCfmMaControlCcInterval, sleCfmMaControlCcPriority, sleCfmMaControlCcLossThreshold }
STATUS current
DESCRIPTION
"setCfmMaCcProfile"
::= { sleCfmMaNotification 5 }
sleCfmMaFaultProfileChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
sleCfmMaControlFaultPriority, sleCfmMaControlFaultKeepTime, sleCfmMaControlFaultClearTime }
STATUS current
DESCRIPTION
"setCfmMaFaultProfile"
::= { sleCfmMaNotification 6 }
sleCfmMaXcheckEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMaControlRequest, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex, sleCfmMaControlMdIndex,
sleCfmMaControlXcheckEnable }
STATUS current
DESCRIPTION
"setCfmMaXcheckEnable"
::= { sleCfmMaNotification 7 }
sleCfmMep OBJECT IDENTIFIER ::= { sleCfmOam 4 }
sleCfmMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMep 1 }
sleCfmMepEntry OBJECT-TYPE
SYNTAX SleCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIfIndex }
::= { sleCfmMepTable 1 }
SleCfmMepEntry ::=
SEQUENCE {
sleCfmMepIdentifier
Integer32,
sleCfmMepIfIndex
Integer32,
sleCfmMepDirection
INTEGER,
sleCfmMepEnable
INTEGER,
sleCfmMepFngState
INTEGER,
sleCfmMepCcEnable
INTEGER,
sleCfmMepMacAddress
OCTET STRING,
sleCfmMepCcPriority
Integer32,
sleCfmMepFaultPriority
INTEGER,
sleCfmMepFaultKeepTime
Integer32,
sleCfmMepFaultClearTime
Integer32,
sleCfmMepHighestPrDefect
INTEGER,
sleCfmMepDefects
BITS,
sleCfmMepCciSentCcms
Counter32,
sleCfmMepNextLbmTransId
Integer32,
sleCfmMepLbrIn
Counter32,
sleCfmMepLbrInOutOfOrder
Counter32,
sleCfmMepLtmNextSeqNumber
Integer32,
sleCfmMepUnexpLtrIn
Counter32
}
sleCfmMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MEP Id"
::= { sleCfmMepEntry 1 }
sleCfmMepIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Brige Port Index whitch the MEP is attached"
::= { sleCfmMepEntry 2 }
sleCfmMepDirection OBJECT-TYPE
SYNTAX INTEGER
{
down(0),
up(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction in which the MEP faces on the Bridge port"
::= { sleCfmMepEntry 3 }
sleCfmMepEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Administrative state of the MEP"
::= { sleCfmMepEntry 4 }
sleCfmMepFngState OBJECT-TYPE
SYNTAX INTEGER
{
reset(1),
defect(2),
reportDefect(3),
defectReported(4),
defectCearing(5),
defectCleared(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of the MEP Fault Notification Generator State Machine"
::= { sleCfmMepEntry 5 }
sleCfmMepCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, the MEP will generate CCM messages"
::= { sleCfmMepEntry 6 }
sleCfmMepMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MEP"
::= { sleCfmMepEntry 7 }
sleCfmMepCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the CCM Priority"
::= { sleCfmMepEntry 8 }
sleCfmMepFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdiccm(1),
macstatus(2),
remoteccm(3),
errorccm(4),
xconccm(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
::= { sleCfmMepEntry 9 }
sleCfmMepFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that defects must be present before a Fault Alarm is issued"
::= { sleCfmMepEntry 10 }
sleCfmMepFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that defects must be absent before resetting a Fault Alarm"
::= { sleCfmMepEntry 11 }
sleCfmMepHighestPrDefect OBJECT-TYPE
SYNTAX INTEGER
{
rdiccm(1),
macstatus(2),
remoteccm(3),
errorccm(4),
xconccm(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine was last in the FNG_RESET state"
::= { sleCfmMepEntry 12 }
sleCfmMepDefects OBJECT-TYPE
SYNTAX BITS
{
rdiccm(0),
macstatus(1),
remoteccm(2),
errorccm(3),
xconccm(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A vector of Boolean defect conditions"
::= { sleCfmMepEntry 13 }
sleCfmMepCciSentCcms OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Continuity Check messages transmitted"
::= { sleCfmMepEntry 14 }
sleCfmMepNextLbmTransId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next sequence number/transaction identifier to be sent in a Loopback message"
::= { sleCfmMepEntry 15 }
sleCfmMepLbrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, in-order Loopback Replies received"
::= { sleCfmMepEntry 16 }
sleCfmMepLbrInOutOfOrder OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid, out-of-order Loopback Replies received"
::= { sleCfmMepEntry 17 }
sleCfmMepLtmNextSeqNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next transaction identifier/sequence number to be sent in a Linktrace message."
::= { sleCfmMepEntry 18 }
sleCfmMepUnexpLtrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of unexpected LTRs received"
::= { sleCfmMepEntry 19 }
sleCfmMepControl OBJECT IDENTIFIER ::= { sleCfmMep 2 }
sleCfmMepControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmMep(1),
deleteCfmMep(2),
setCfmMepEnable(3),
setCfmMepCcEnable(4),
setCfmMepCcProfile(5),
setCfmMepFaultProfile(6),
transmitCfmLbm(7),
transmitCfmLtm(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMepControl 1 }
sleCfmMepControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMepControl 2 }
sleCfmMepControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMepControl 3 }
sleCfmMepControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMepControl 4 }
sleCfmMepControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMepControl 5 }
sleCfmMepControlIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MEP Id"
::= { sleCfmMepControl 6 }
sleCfmMepControlMdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A index of MD table"
::= { sleCfmMepControl 7 }
sleCfmMepControlMaIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MA's Index"
::= { sleCfmMepControl 8 }
sleCfmMepControlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridge Port Index whitch the MEP is attached"
::= { sleCfmMepControl 9 }
sleCfmMepControlDirection OBJECT-TYPE
SYNTAX INTEGER
{
down(0),
up(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The direction in which the MEP faces on the Bridge port"
::= { sleCfmMepControl 10 }
sleCfmMepControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative state of the MEP"
::= { sleCfmMepControl 11 }
sleCfmMepControlCcEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If set to true, the MEP will generate CCM messages"
::= { sleCfmMepControl 12 }
sleCfmMepControlCcPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the CCM Priority"
::= { sleCfmMepControl 13 }
sleCfmMepControlFaultPriority OBJECT-TYPE
SYNTAX INTEGER
{
rdiccm(1),
macstatus(2),
remoteccm(3),
errorccm(4),
xconccm(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An integer value specifying the lowest priority defect that is allowed to generate fault alarm"
::= { sleCfmMepControl 14 }
sleCfmMepControlFaultKeepTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time that defects must be present before a Fault Alarm is issued"
::= { sleCfmMepControl 15 }
sleCfmMepControlFaultClearTime OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time that defects must be absent before resetting a Fault Alarm"
::= { sleCfmMepControl 16 }
sleCfmMepControlTransmitLbmDestMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted"
::= { sleCfmMepControl 17 }
sleCfmMepControlTransmitLbmDestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent"
::= { sleCfmMepControl 18 }
sleCfmMepControlTransmitLbmDestIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True indicates that MEPID of the target MEP is used for Loopback transmission"
::= { sleCfmMepControl 19 }
sleCfmMepControlTransmitLbmCount OBJECT-TYPE
SYNTAX Integer32 (1..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of Loopback messages to be transmitted"
::= { sleCfmMepControl 20 }
sleCfmMepControlTransmitLbmInterval OBJECT-TYPE
SYNTAX Integer32 (2..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending LBM"
::= { sleCfmMepControl 21 }
sleCfmMepControlTransmitLbmTimeout OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the waiting time for receiving the expected LBR"
::= { sleCfmMepControl 22 }
sleCfmMepControlTransmitLbmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag"
::= { sleCfmMepControl 23 }
sleCfmMepControlTransmitLtmTargetMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted: A unicast destination MAC address."
::= { sleCfmMepControl 24 }
sleCfmMepControlTransmitLtmTargetMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An indication of the Target MAC Address Field to be transmitted"
::= { sleCfmMepControl 25 }
sleCfmMepControlTransmitLtmTargetIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True indicates that MEPID of the target MEP is used for Linktrace transmission."
::= { sleCfmMepControl 26 }
sleCfmMepControlTransmitLtmFlags OBJECT-TYPE
SYNTAX BITS { useFDBonly(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The flags field for LTMs transmitted by the MEP"
::= { sleCfmMepControl 27 }
sleCfmMepControlTransmitLtmTtl OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The LTM TTL field"
::= { sleCfmMepControl 28 }
sleCfmMepNotification OBJECT IDENTIFIER ::= { sleCfmMep 3 }
sleCfmMepCreated NOTIFICATION-TYPE
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
sleCfmMepControlMaIndex, sleCfmMepControlIfIndex, sleCfmMepControlDirection }
STATUS current
DESCRIPTION
"createCfmMep"
::= { sleCfmMepNotification 1 }
sleCfmMepDeleted NOTIFICATION-TYPE
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
sleCfmMepControlMaIndex }
STATUS current
DESCRIPTION
"deleteCfmMep"
::= { sleCfmMepNotification 2 }
sleCfmMepEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
sleCfmMepControlMaIndex, sleCfmMepControlEnable }
STATUS current
DESCRIPTION
"setCfmMepEnable"
::= { sleCfmMepNotification 3 }
sleCfmMepCcEnableChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
sleCfmMepControlMaIndex, sleCfmMepControlCcEnable }
STATUS current
DESCRIPTION
"setCfmMepCcEnable"
::= { sleCfmMepNotification 4 }
sleCfmMepCcProfileChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
sleCfmMepControlMaIndex, sleCfmMdControlCcPriority }
STATUS current
DESCRIPTION
"setCfmMepCcProfile"
::= { sleCfmMepNotification 5 }
sleCfmMepFaultProfileChanged NOTIFICATION-TYPE
OBJECTS { sleCfmMepControlRequest, sleCfmMepControlTimeStamp, sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex,
sleCfmMepControlMaIndex, sleCfmMepControlFaultPriority, sleCfmMepControlFaultKeepTime, sleCfmMepControlFaultClearTime }
STATUS current
DESCRIPTION
"setCfmMepFaultProfile"
::= { sleCfmMepNotification 6 }
sleCfmMip OBJECT IDENTIFIER ::= { sleCfmOam 5 }
sleCfmMipTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMip 1 }
sleCfmMipEntry OBJECT-TYPE
SYNTAX SleCfmMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMipPort }
::= { sleCfmMipTable 1 }
SleCfmMipEntry ::=
SEQUENCE {
sleCfmMipPort
Integer32,
sleCfmMipLevel
Integer32,
sleCfmMipType
INTEGER
}
sleCfmMipPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the port number"
::= { sleCfmMipEntry 1 }
sleCfmMipLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MIP's level"
::= { sleCfmMipEntry 2 }
sleCfmMipType OBJECT-TYPE
SYNTAX INTEGER
{
static(1),
dynamic(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the MIP<49><50>s type"
::= { sleCfmMipEntry 3 }
sleCfmMipControl OBJECT IDENTIFIER ::= { sleCfmMip 2 }
sleCfmMipControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmMip(1),
deleteCfmMip(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMipControl 1 }
sleCfmMipControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMipControl 2 }
sleCfmMipControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMipControl 3 }
sleCfmMipControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMipControl 4 }
sleCfmMipControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMipControl 5 }
sleCfmMipControlPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the port number"
::= { sleCfmMipControl 6 }
sleCfmMipControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MIP's level"
::= { sleCfmMipControl 7 }
sleCfmMipNotification OBJECT IDENTIFIER ::= { sleCfmMip 3 }
sleCfmMipCreated NOTIFICATION-TYPE
OBJECTS { sleCfmMipControlRequest, sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort, sleCfmMipControlLevel
}
STATUS current
DESCRIPTION
"createCfmMip"
::= { sleCfmMipNotification 1 }
sleCfmMipDeleted NOTIFICATION-TYPE
OBJECTS { sleCfmMipControlRequest, sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort }
STATUS current
DESCRIPTION
"deleteCfmMip"
::= { sleCfmMipNotification 2 }
sleCfmXcheck OBJECT IDENTIFIER ::= { sleCfmOam 6 }
sleCfmXcheckTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmXcheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmXcheck 1 }
sleCfmXcheckEntry OBJECT-TYPE
SYNTAX SleCfmXcheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmXcheckMepIdentifier }
::= { sleCfmXcheckTable 1 }
SleCfmXcheckEntry ::=
SEQUENCE {
sleCfmXcheckMepIdentifier
Integer32,
sleCfmXcheckMepState
INTEGER
}
sleCfmXcheckMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the remote MEP's Id"
::= { sleCfmXcheckEntry 1 }
sleCfmXcheckMepState OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
missing(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the cross-check MEP<45><50>s state"
::= { sleCfmXcheckEntry 2 }
sleCfmXcheckControl OBJECT IDENTIFIER ::= { sleCfmXcheck 2 }
sleCfmXcheckControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmXcheckMep(1),
deleteCfmXcheckMep(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmXcheckControl 1 }
sleCfmXcheckControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmXcheckControl 2 }
sleCfmXcheckControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleCfmXcheckControl 3 }
sleCfmXcheckControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmXcheckControl 4 }
sleCfmXcheckControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleCfmXcheckControl 5 }
sleCfmXcheckControlMepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the remote MEP's Id"
::= { sleCfmXcheckControl 6 }
sleCfmXcheckControlMdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MD<4D><44>s Index"
::= { sleCfmXcheckControl 7 }
sleCfmXcheckControlMaIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the MA's Index"
::= { sleCfmXcheckControl 8 }
sleCfmXcheckNotification OBJECT IDENTIFIER ::= { sleCfmXcheck 3 }
sleCfmXcheckMepCreated NOTIFICATION-TYPE
OBJECTS { sleCfmXcheckControlRequest, sleCfmXcheckControlTimeStamp, sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex,
sleCfmXcheckControlMaIndex }
STATUS current
DESCRIPTION
"createCfmXcheckMep"
::= { sleCfmXcheckNotification 1 }
sleCfmXcheckMepDeleted NOTIFICATION-TYPE
OBJECTS { sleCfmXcheckControlRequest, sleCfmXcheckControlTimeStamp, sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex,
sleCfmXcheckControlMaIndex }
STATUS current
DESCRIPTION
"deleteCfmXcheckMep"
::= { sleCfmXcheckNotification 2 }
sleCfmRmep OBJECT IDENTIFIER ::= { sleCfmOam 7 }
sleCfmRmepTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmRmepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmRmep 1 }
sleCfmRmepEntry OBJECT-TYPE
SYNTAX SleCfmRmepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIdentifier, sleCfmRmepIdentifier }
::= { sleCfmRmepTable 1 }
SleCfmRmepEntry ::=
SEQUENCE {
sleCfmRmepIdentifier
Integer32,
sleCfmRmepState
INTEGER,
sleCfmRmepMacAddress
OCTET STRING,
sleCfmRmepIfIndex
Integer32,
sleCfmRmepRdi
INTEGER,
sleCfmRmepPortStatus
INTEGER,
sleCfmRmepInterfaceStatus
INTEGER
}
sleCfmRmepIdentifier OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the remote MEP's Id"
::= { sleCfmRmepEntry 1 }
sleCfmRmepState OBJECT-TYPE
SYNTAX INTEGER
{
idle(1),
start(2),
failed(3),
ok(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the operational state of the remote MEP State machines"
::= { sleCfmRmepEntry 2 }
sleCfmRmepMacAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MAC address of the remote MEP"
::= { sleCfmRmepEntry 3 }
sleCfmRmepIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the port number of the remote MEP"
::= { sleCfmRmepEntry 4 }
sleCfmRmepRdi OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received"
::= { sleCfmRmepEntry 5 }
sleCfmRmepPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Port status of the remote MEP"
::= { sleCfmRmepEntry 6 }
sleCfmRmepInterfaceStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interface status of the remote MEP"
::= { sleCfmRmepEntry 7 }
sleCfmLtr OBJECT IDENTIFIER ::= { sleCfmOam 8 }
sleCfmLtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmLtr 1 }
sleCfmLtrEntry OBJECT-TYPE
SYNTAX SleCfmLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMdIndex, sleCfmMaIndex, sleCfmMepIdentifier, sleCfmLtrSeqNumber, sleCfmLtrReceiveOrder
}
::= { sleCfmLtrTable 1 }
SleCfmLtrEntry ::=
SEQUENCE {
sleCfmLtrSeqNumber
Integer32,
sleCfmLtrReceiveOrder
Integer32,
sleCfmLtrTtl
Integer32,
sleCfmLtrForwarded
INTEGER,
sleCfmLtrTerminalMep
INTEGER,
sleCfmLtrLastEgressIdentifier
OCTET STRING,
sleCfmLtrNextEgressIdentifier
OCTET STRING,
sleCfmLtrRelay
INTEGER,
sleCfmLtrIngress
INTEGER,
sleCfmLtrIngressMac
OCTET STRING,
sleCfmLtrIngressPort
Integer32,
sleCfmLtrEgress
INTEGER,
sleCfmLtrEgressMac
OCTET STRING,
sleCfmLtrEgressPort
Integer32
}
sleCfmLtrSeqNumber OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the LTM Transaction Identifier returned from a previous Transmit Linktrace Message command,
indicating the LTM entry to which the LTR entries will be attached
"
::= { sleCfmLtrEntry 1 }
sleCfmLtrReceiveOrder OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates an index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value"
::= { sleCfmLtrEntry 2 }
sleCfmLtrTtl OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates TTL field value for a returned LTR."
::= { sleCfmLtrEntry 3 }
sleCfmLtrForwarded OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field."
::= { sleCfmLtrEntry 4 }
sleCfmLtrTerminalMep OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates a boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field. "
::= { sleCfmLtrEntry 5 }
sleCfmLtrLastEgressIdentifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the MEP Linktrace Initiator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response"
::= { sleCfmLtrEntry 6 }
sleCfmLtrNextEgressIdentifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop."
::= { sleCfmLtrEntry 7 }
sleCfmLtrRelay OBJECT-TYPE
SYNTAX INTEGER
{
rlyHit(1),
rlyFDB(2),
rlyMPDB(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value returned in the Ingress Action Field of the LTM"
::= { sleCfmLtrEntry 8 }
sleCfmLtrIngress OBJECT-TYPE
SYNTAX INTEGER
{
ingNoTlv(0),
ingOK(1),
ingDown(2),
ingBlocked(3),
ingVid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value returned in the Ingress Action Field of the LTM"
::= { sleCfmLtrEntry 9 }
sleCfmLtrIngressMac OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates MAC address returned in the ingress MAC address field."
::= { sleCfmLtrEntry 10 }
sleCfmLtrIngressPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Ingress Port ID"
::= { sleCfmLtrEntry 11 }
sleCfmLtrEgress OBJECT-TYPE
SYNTAX INTEGER
{
egrNoTlv(0),
egrOK(1),
egrDown(2),
egrBlocked(3),
egrVid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value returned in the Egress Action Field of the LTM"
::= { sleCfmLtrEntry 12 }
sleCfmLtrEgressMac OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates MAC address returned in the egress MAC address field."
::= { sleCfmLtrEntry 13 }
sleCfmLtrEgressPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Egress Port ID"
::= { sleCfmLtrEntry 14 }
sleCfmConfigError OBJECT IDENTIFIER ::= { sleCfmOam 9 }
sleCfmConfigErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmConfigErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmConfigError 1 }
sleCfmConfigErrorEntry OBJECT-TYPE
SYNTAX SleCfmConfigErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmConfigErrorVid, sleCfmConfigErrorIfIndex }
::= { sleCfmConfigErrorTable 1 }
SleCfmConfigErrorEntry ::=
SEQUENCE {
sleCfmConfigErrorVid
Integer32,
sleCfmConfigErrorIfIndex
Integer32,
sleCfmConfigErrorType
BITS
}
sleCfmConfigErrorVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Configuration Error VLAN Identifier"
::= { sleCfmConfigErrorEntry 1 }
sleCfmConfigErrorIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Configuration Error Port Number"
::= { sleCfmConfigErrorEntry 2 }
sleCfmConfigErrorType OBJECT-TYPE
SYNTAX BITS
{
cfmleak(0),
conflictingVids(1),
excessiveLevels(2),
overlappedLevels(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Configuration Error Type"
::= { sleCfmConfigErrorEntry 3 }
sleCfmMipCcdb OBJECT IDENTIFIER ::= { sleCfmOam 10 }
sleCfmMipCcdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleCfmMipCcdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleCfmMipCcdb 1 }
sleCfmMipCcdbEntry OBJECT-TYPE
SYNTAX SleCfmMipCcdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleCfmMipCcdbIndex }
::= { sleCfmMipCcdbTable 1 }
SleCfmMipCcdbEntry ::=
SEQUENCE {
sleCfmMipCcdbIndex
Integer32,
sleCfmMipCcdbVlanId
Integer32,
sleCfmMipCcdbMacAddr
OCTET STRING,
sleCfmMipCcdbPort
Integer32,
sleCfmMipCcdbKeepTime
OCTET STRING
}
sleCfmMipCcdbIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the MIP CCDB's Index"
::= { sleCfmMipCcdbEntry 1 }
sleCfmMipCcdbVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN Id"
::= { sleCfmMipCcdbEntry 2 }
sleCfmMipCcdbMacAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates MAC address of the remote MEP"
::= { sleCfmMipCcdbEntry 3 }
sleCfmMipCcdbPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Port number that the CCM output"
::= { sleCfmMipCcdbEntry 4 }
sleCfmMipCcdbKeepTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates an up-date time of a entry"
::= { sleCfmMipCcdbEntry 5 }
sleEMLog OBJECT IDENTIFIER ::= { sleFaultMgmt 14 }
sleEMLogInfo OBJECT IDENTIFIER ::= { sleEMLog 1 }
sleEMLogDisableStatus OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"EM log disable."
::= { sleEMLogInfo 1 }
sleEMLogAction OBJECT-TYPE
SYNTAX BITS
{
syslog(0),
trap(1),
recover(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Generate syslog message or SNMP Trap or take a recover action
"
::= { sleEMLogInfo 2 }
sleEMLogInterval OBJECT-TYPE
SYNTAX INTEGER (1..1440)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Action interval in minute (Default. 3 mins)"
::= { sleEMLogInfo 3 }
sleEMLogNAKLockStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of emlog nak-locking"
::= { sleEMLogInfo 4 }
sleEMLogNakCompensate OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of emlog nak-compensate (shadow recovery)"
::= { sleEMLogInfo 5 }
sleEMLogRecoverActionMemLow OBJECT-TYPE
SYNTAX INTEGER
{
switchover(1),
none(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate recover action of memory low"
::= { sleEMLogInfo 6 }
sleEMLogRecoverActionNak OBJECT-TYPE
SYNTAX INTEGER
{
switchover(1),
none(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate recover action of NAK error"
::= { sleEMLogInfo 7 }
sleEMLogControl OBJECT IDENTIFIER ::= { sleEMLog 2 }
sleEMLogControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setDisableStatus(1),
setAction(2),
setInterval(3),
setNAKLock(4),
setNAKCompensate(5),
setRecoverActionMemLow(6),
setRecoverActionNAK(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This attribute identifies the control commands.
updateAlarmList:
the NE updates entries of alarms in the sleAlarmListTable
after having changed alarm severities of alarms
(due to change profile pointers in
managed entities or after modification of alarm severities
in profiles). This command should be applied once after having
finisled modifications of severties.
modifyAlarmSeverity:
modifies the severity of an alarm in specific profile.
createAlarmSeverityProfile:
creates a new profile with default severities.
The severities then have to be modified with command changeAlarmSeverity.
deleteAlarmSeverityProfile:
deletes a profile. Profile 1 is not allowed to be deleted.
Notifications : none "
::= { sleEMLogControl 1 }
sleEMLogControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleEMLogControl 2 }
sleEMLogControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleEMLogControl 3 }
sleEMLogControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleEMLogControl 4 }
sleEMLogControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleEMLogControl 5 }
sleEMLogControlDisableStatus OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"EM log disable."
::= { sleEMLogControl 6 }
sleEMLogControlAction OBJECT-TYPE
SYNTAX BITS
{
syslog(0),
trap(1),
recover(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Generate syslog message or SNMP trap."
::= { sleEMLogControl 7 }
sleEMLogControlInterval OBJECT-TYPE
SYNTAX INTEGER (1..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Action interval in minute (Default. 3 mins)"
::= { sleEMLogControl 8 }
sleEMLogControlNAKLockStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of emlog nak-locking"
::= { sleEMLogControl 9 }
sleEMLogControlNAKCompensate OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of emlog nak-compensate (shadow recovery)"
::= { sleEMLogControl 10 }
sleEMLogControlRecoverActionMemLow OBJECT-TYPE
SYNTAX INTEGER
{
switchover(1),
none(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate recover action of memory low"
::= { sleEMLogControl 11 }
sleEMLogControlRecoverActionNAK OBJECT-TYPE
SYNTAX INTEGER
{
switchover(1),
none(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate recover action of NAK error
"
::= { sleEMLogControl 12 }
sleEMLogNotification OBJECT IDENTIFIER ::= { sleEMLog 3 }
sleEMLogDisableStatusChanged NOTIFICATION-TYPE
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlDisableStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleEMLogNotification 1 }
sleEMLogActionChanged NOTIFICATION-TYPE
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlAction }
STATUS current
DESCRIPTION
"Description."
::= { sleEMLogNotification 2 }
sleEMLogIntervalChanged NOTIFICATION-TYPE
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlInterval }
STATUS current
DESCRIPTION
"Description."
::= { sleEMLogNotification 3 }
sleEMLogNAKLockChanged NOTIFICATION-TYPE
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlNAKLockStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleEMLogNotification 4 }
sleEMLogNAKCompensateChanged NOTIFICATION-TYPE
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlNAKCompensate }
STATUS current
DESCRIPTION
"Description."
::= { sleEMLogNotification 5 }
sleEMLogRecoverActionMemLowChanged NOTIFICATION-TYPE
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlRecoverActionMemLow }
STATUS current
DESCRIPTION
"Description."
::= { sleEMLogNotification 6 }
sleEMLogRecoverActionNAKChanged NOTIFICATION-TYPE
OBJECTS { sleEMLogControlRequest, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlRecoverActionNAK }
STATUS current
DESCRIPTION
"Description."
::= { sleEMLogNotification 7 }
sleEMLogDefectInfo OBJECT IDENTIFIER ::= { sleEMLog 4 }
sleEMLogDefectCPUHigh OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU high defection information."
::= { sleEMLogDefectInfo 1 }
sleEMLogTemperHigh OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature hish defection information."
::= { sleEMLogDefectInfo 2 }
sleEMLogTemperLow OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature low defection information."
::= { sleEMLogDefectInfo 3 }
sleEMLogMemLow OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The memory low defection information."
::= { sleEMLogDefectInfo 4 }
sleEMLogFanFail OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fan failure defection information."
::= { sleEMLogDefectInfo 5 }
sleEMLogPhyCRCFail OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PHY CRC failure defection information."
::= { sleEMLogDefectInfo 6 }
sleEMLogPhyDetectFail OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PHY detection failure defection information."
::= { sleEMLogDefectInfo 7 }
sleEMLogSFUMateInitFail OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFU mate init failure defection information"
::= { sleEMLogDefectInfo 8 }
sleEMLogDaemonHealthBad OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The daemon health bad defection information."
::= { sleEMLogDefectInfo 9 }
sleEMLogGPIURavenLinkDown OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The GPIU raven link down defection information."
::= { sleEMLogDefectInfo 10 }
sleEMLogFANRPMLow OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The FAN RPM Low defection information."
::= { sleEMLogDefectInfo 11 }
sleEMLogNAK OBJECT-TYPE
SYNTAX BITS
{
slot1(0),
slot2(1),
slot3(2),
slot4(3),
slot5(4),
slot6(5),
slot7(6),
slot8(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The NAK Error defection information."
::= { sleEMLogDefectInfo 12 }
sleRapsRing OBJECT IDENTIFIER ::= { sleFaultMgmt 15 }
sleRapsRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleRapsRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleRapsRing 1 }
sleRapsRingEntry OBJECT-TYPE
SYNTAX SleRapsRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleRapsRingId }
::= { sleRapsRingTable 1 }
SleRapsRingEntry ::=
SEQUENCE {
sleRapsRingId
Integer32,
sleRapsRingType
INTEGER,
sleRapsRingLevel
INTEGER,
sleRapsRingCtrlVlan
INTEGER,
sleRapsRingTrafficVlans
OCTET STRING,
sleRapsRingVirtualVlan
INTEGER,
sleRapsRingNodeId
OCTET STRING,
sleRapsRingEnable
INTEGER,
sleRapsRingBridgeRole
INTEGER,
sleRapsRingState
INTEGER,
sleRapsRingEastPort
Integer32,
sleRapsRingEastPortStatus
INTEGER,
sleRapsRingWestPort
Integer32,
sleRapsRingWestPortStatus
INTEGER,
sleRapsRingRplPort
INTEGER,
sleRapsRingIcPort
INTEGER,
sleRapsRingIcNode
INTEGER,
sleRapsRingMultipleFailure
INTEGER,
sleRapsRingPropagateTc
INTEGER,
sleRapsRingNonRevertive
INTEGER,
sleRapsRingForcedSwitch
INTEGER,
sleRapsRingManualSwitch
INTEGER,
sleRapsRingHoldOffTime
INTEGER,
sleRapsRingGuardTime
INTEGER,
sleRapsRingWaitToRestore
INTEGER,
sleRapsRingWaitToBlock
INTEGER,
sleRapsRingInstId
Integer32,
sleRapsRingChannel
INTEGER,
sleRapsRingPassThrough
INTEGER,
sleRapsRingVerifiedTime
INTEGER
}
sleRapsRingId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s ID"
::= { sleRapsRingEntry 1 }
sleRapsRingType OBJECT-TYPE
SYNTAX INTEGER
{
major(1),
sub(2),
access(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s type"
::= { sleRapsRingEntry 2 }
sleRapsRingLevel OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s level"
::= { sleRapsRingEntry 3 }
sleRapsRingCtrlVlan OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s control-vlan"
::= { sleRapsRingEntry 4 }
sleRapsRingTrafficVlans OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s traffic-vlans"
::= { sleRapsRingEntry 5 }
sleRapsRingVirtualVlan OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node's virtual-vlan"
::= { sleRapsRingEntry 6 }
sleRapsRingNodeId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s ID"
::= { sleRapsRingEntry 7 }
sleRapsRingEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables/Disables Ring Node"
::= { sleRapsRingEntry 8 }
sleRapsRingBridgeRole OBJECT-TYPE
SYNTAX INTEGER
{
normal(0),
rplowner(1),
rplneighbour(2),
rplnextneighbour(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s Role"
::= { sleRapsRingEntry 9 }
sleRapsRingState OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
idle(1),
protection(2),
manual(3),
forced(4),
pending(5),
required(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s State"
::= { sleRapsRingEntry 10 }
sleRapsRingEastPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s east port"
::= { sleRapsRingEntry 11 }
sleRapsRingEastPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
disabled(1),
forwarding(2),
blocking(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the port status of east port"
::= { sleRapsRingEntry 12 }
sleRapsRingWestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s west port"
::= { sleRapsRingEntry 13 }
sleRapsRingWestPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
disabled(1),
forwarding(2),
blocking(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the port status of west port"
::= { sleRapsRingEntry 14 }
sleRapsRingRplPort OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
east(1),
west(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s RPL port"
::= { sleRapsRingEntry 15 }
sleRapsRingIcPort OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
east(1),
west(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s interconnection port"
::= { sleRapsRingEntry 16 }
sleRapsRingIcNode OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
primary(1),
secondary(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the primary/secondary node for the minimization of the segmentation"
::= { sleRapsRingEntry 17 }
sleRapsRingMultipleFailure OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
primary(1),
secondary(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The multiple failure mode"
::= { sleRapsRingEntry 18 }
sleRapsRingPropagateTc OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The propagation TC(topology change)"
::= { sleRapsRingEntry 19 }
sleRapsRingNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Non-Revertive"
::= { sleRapsRingEntry 20 }
sleRapsRingForcedSwitch OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
east(1),
west(2),
both(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Forced Switch"
::= { sleRapsRingEntry 21 }
sleRapsRingManualSwitch OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
east(1),
west(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Manual Switch"
::= { sleRapsRingEntry 22 }
sleRapsRingHoldOffTime OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the hold-off time"
::= { sleRapsRingEntry 23 }
sleRapsRingGuardTime OBJECT-TYPE
SYNTAX INTEGER (10..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the guard time"
::= { sleRapsRingEntry 24 }
sleRapsRingWaitToRestore OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time"
::= { sleRapsRingEntry 25 }
sleRapsRingWaitToBlock OBJECT-TYPE
SYNTAX INTEGER (5..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the wait-to-block time"
::= { sleRapsRingEntry 26 }
sleRapsRingInstId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ring instance ID."
::= { sleRapsRingEntry 27 }
sleRapsRingChannel OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
virtual(1),
abstract(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the R-APS channel type."
::= { sleRapsRingEntry 28 }
sleRapsRingPassThrough OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the pass-through funtion."
::= { sleRapsRingEntry 29 }
sleRapsRingVerifiedTime OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the verified time"
::= { sleRapsRingEntry 30 }
sleRapsRingControl OBJECT IDENTIFIER ::= { sleRapsRing 2 }
sleRapsRingControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createRapsRing(1),
deleteRapsRing(2),
setRapsRingChannel(3),
setRapsRingEnable(4),
setRapsRingPorts(5),
destroyRapsRingPorts(6),
setRapsRingRplPort(7),
setRapsRingIcPort(8),
destroyRapsRingIcPort(9),
setRapsRingMultipleFailure(10),
setRapsRingPropagateTc(11),
setRapsRingNonRevertive(12),
setRapsRingForcedSwitch(13),
setRapsRingManualSwitch(14),
setRapsRingClearSwitch(15),
setRapsRingHoldOffTime(16),
setRapsRingGuardTime(17),
setRapsRingWtrTime(18),
setRapsRingWtbTime(19),
setRapsRingPassThrough(20),
setRapsRingVrfTime(21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleRapsRingControl 1 }
sleRapsRingControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleRapsRingControl 2 }
sleRapsRingControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleRapsRingControl 3 }
sleRapsRingControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleRapsRingControl 4 }
sleRapsRingControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleRapsRingControl 5 }
sleRapsRingControlId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s ID"
::= { sleRapsRingControl 6 }
sleRapsRingControlType OBJECT-TYPE
SYNTAX INTEGER
{
major(1),
sub(2),
access(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s type"
::= { sleRapsRingControl 7 }
sleRapsRingControlLevel OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s level"
::= { sleRapsRingControl 8 }
sleRapsRingControlCtrlVlan OBJECT-TYPE
SYNTAX INTEGER (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s control-vlan"
::= { sleRapsRingControl 9 }
sleRapsRingControlTrafficVlans OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s traffic-vlans"
::= { sleRapsRingControl 10 }
sleRapsRingControlChannel OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
virtual(1),
abstract(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node's channel"
::= { sleRapsRingControl 11 }
sleRapsRingControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IEnables/Disables Ring Node"
::= { sleRapsRingControl 12 }
sleRapsRingControlEastPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s east port"
::= { sleRapsRingControl 13 }
sleRapsRingControlWestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64><65>s west port"
::= { sleRapsRingControl 14 }
sleRapsRingControlParamPort OBJECT-TYPE
SYNTAX INTEGER
{
east(1),
west(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the rpl port, interconnection port, forced or manual switch port."
::= { sleRapsRingControl 15 }
sleRapsRingControlBridgeRole OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
rplowner(1),
neighbour(2),
nextneighbour(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring<6E><67>s RPL port type"
::= { sleRapsRingControl 16 }
sleRapsRingControlIcNode OBJECT-TYPE
SYNTAX INTEGER
{
primary(1),
secondary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the primary/secondary node for the minimization of the segmentation"
::= { sleRapsRingControl 17 }
sleRapsRingControlMultipleFailure OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
primary(1),
secondary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The multiple failure of Ring Node"
::= { sleRapsRingControl 18 }
sleRapsRingControlPropagateTc OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The propagation TC"
::= { sleRapsRingControl 19 }
sleRapsRingControlNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Non-Revertive"
::= { sleRapsRingControl 20 }
sleRapsRingControlHoldOffTime OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the hold-off time.
The hold-off time's step must be 100
"
::= { sleRapsRingControl 21 }
sleRapsRingControlGuardTime OBJECT-TYPE
SYNTAX INTEGER (10..2000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the guard time.
The guard time's step must be 10.
"
::= { sleRapsRingControl 22 }
sleRapsRingControlWaitToRestore OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time
"
::= { sleRapsRingControl 23 }
sleRapsRingControlWaitToBlock OBJECT-TYPE
SYNTAX INTEGER (5..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the wait-to-block time"
::= { sleRapsRingControl 24 }
sleRapsRingControlInstId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the ring instance ID."
::= { sleRapsRingControl 25 }
sleRapsRingControlPassThrough OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the pass-through function."
::= { sleRapsRingControl 26 }
sleRapsRingControlVerifiedTime OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the verified time."
::= { sleRapsRingControl 27 }
sleRapsRingNotification OBJECT IDENTIFIER ::= { sleRapsRing 3 }
sleRapsRingCreated NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlId,
sleRapsRingControlType, sleRapsRingControlLevel, sleRapsRingControlCtrlVlan, sleRapsRingControlTrafficVlans }
STATUS current
DESCRIPTION
"createRapsRing"
::= { sleRapsRingNotification 1 }
sleRapsRingDeleted NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId }
STATUS current
DESCRIPTION
"deleteRapsRing"
::= { sleRapsRingNotification 2 }
sleRapsRingChannelChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlChannel
}
STATUS current
DESCRIPTION
"setRapsRingChannel"
::= { sleRapsRingNotification 3 }
sleRapsRingEnableChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlEnable
}
STATUS current
DESCRIPTION
"setRapsRingEnable"
::= { sleRapsRingNotification 4 }
sleRapsRingPortsCreated NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlEastPort,
sleRapsRingControlWestPort, sleRapsRingControlParamPort }
STATUS current
DESCRIPTION
"setRapsRingPorts"
::= { sleRapsRingNotification 5 }
sleRapsRingPortsDestroyed NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId }
STATUS current
DESCRIPTION
"destroyRapsRingPorts"
::= { sleRapsRingNotification 6 }
sleRapsRingRplPortChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlBridgeRole,
sleRapsRingControlParamPort }
STATUS current
DESCRIPTION
"setRapsRingRplPort"
::= { sleRapsRingNotification 7 }
sleRapsRingIcPortCreated NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlIcNode, sleRapsRingControlParamPort,
sleRapsRingControlInstId }
STATUS current
DESCRIPTION
"setRapsRingIcPort"
::= { sleRapsRingNotification 8 }
sleRapsRingIcPortDestroyed NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlId }
STATUS current
DESCRIPTION
"destroyRapsRingIcPort"
::= { sleRapsRingNotification 9 }
sleRapsRingMultipleFailureChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlMultipleFailure
}
STATUS current
DESCRIPTION
"setRapsRingMultipleFailure"
::= { sleRapsRingNotification 10 }
sleRapsRingPropagateTcChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlPropagateTc
}
STATUS current
DESCRIPTION
"setRapsRingPropagateTc"
::= { sleRapsRingNotification 11 }
sleRapsRingNonRevertiveChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlNonRevertive
}
STATUS current
DESCRIPTION
"setRapsRingNonRevertive"
::= { sleRapsRingNotification 12 }
sleRapsRingForcedSwitchChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlParamPort
}
STATUS current
DESCRIPTION
"setRapsRingForcedSwitch"
::= { sleRapsRingNotification 13 }
sleRapsRingManualSwitchChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlParamPort
}
STATUS current
DESCRIPTION
"setRapsRingManualSwitch"
::= { sleRapsRingNotification 14 }
sleRapsRingSwitchCleared NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId }
STATUS current
DESCRIPTION
"setRapsRingClearSwitch"
::= { sleRapsRingNotification 15 }
sleRapsRingHoldOffTimeChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlHoldOffTime
}
STATUS current
DESCRIPTION
"setRapsRingHoldOffTime"
::= { sleRapsRingNotification 16 }
sleRapsRingGuardTimeChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlGuardTime
}
STATUS current
DESCRIPTION
"setRapsRingGuardTime"
::= { sleRapsRingNotification 17 }
sleRapsRingWtrTimeChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlWaitToRestore
}
STATUS current
DESCRIPTION
"setRapsRingWtrTime"
::= { sleRapsRingNotification 18 }
sleRapsRingWtbTimeChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlWaitToBlock
}
STATUS current
DESCRIPTION
"setRapsRingWtbTime"
::= { sleRapsRingNotification 19 }
sleRapsRingPassThroughChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlPassThrough
}
STATUS current
DESCRIPTION
"setRapsRingPassThrough"
::= { sleRapsRingNotification 20 }
sleRapsRingVrfTimeChanged NOTIFICATION-TYPE
OBJECTS { sleRapsRingControlRequest, sleRapsRingControlTimeStamp, sleRapsRingControlReqResult, sleRapsRingControlInstId, sleRapsRingControlVerifiedTime
}
STATUS current
DESCRIPTION
"setRapsRingVrfTime"
::= { sleRapsRingNotification 21 }
sleFaultMonitor OBJECT IDENTIFIER ::= { sleFaultMgmt 16 }
sleFaultMonitorGlobal OBJECT IDENTIFIER ::= { sleFaultMonitor 1 }
sleFaultMonitorGlobalBase OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 1 }
sleFaultMonitorGlobalInspectInterval OBJECT-TYPE
SYNTAX INTEGER (3..86400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"daemon Inspection value.
unit : sec, default : 5
"
::= { sleFaultMonitorGlobalBase 1 }
sleFaultMonitorGlobalStartupThreshold OBJECT-TYPE
SYNTAX INTEGER (100..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"daemon startup threshold value.
unit : sec, default : 100
"
::= { sleFaultMonitorGlobalBase 2 }
sleFaultMonitorGlobalNoKeepalive OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
resetMate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate action when don't receive keepalive msg.
"
::= { sleFaultMonitorGlobalBase 3 }
sleFaultMonitorGlobalControl OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 2 }
sleFaultMonitorGlobalControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setGlobalInspectInterval(1),
setGlobalStartupThreshold(2),
setNoKeepaliveAction(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { sleFaultMonitorGlobalControl 1 }
sleFaultMonitorGlobalControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleFaultMonitorGlobalControl 2 }
sleFaultMonitorGlobalControlTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleFaultMonitorGlobalControl 3 }
sleFaultMonitorGlobalControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleFaultMonitorGlobalControl 4 }
sleFaultMonitorGlobalControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleFaultMonitorGlobalControl 5 }
sleFaultMonitorGlobalControlInspectInterval OBJECT-TYPE
SYNTAX INTEGER (3..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"daemon Inspection value.
unit : sec, default : 5
"
::= { sleFaultMonitorGlobalControl 6 }
sleFaultMonitorGlobalControlStartupThreshold OBJECT-TYPE
SYNTAX INTEGER (100..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"daemon startup threshold value.
unit : sec, default : 100
"
::= { sleFaultMonitorGlobalControl 7 }
sleFaultMonitorGlobalControlNoKeepalive OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
switchover(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate action when don't receive keepalive msg.
"
::= { sleFaultMonitorGlobalControl 8 }
sleFaultMonitorGlobalNotification OBJECT IDENTIFIER ::= { sleFaultMonitorGlobal 3 }
setFaultMonitorGlobalInspectIntervalChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlInspectInterval }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorGlobalNotification 1 }
setFaultMonitorGlobalStartupThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlStartupThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorGlobalNotification 2 }
setFaultMonitorGlobalNoKeepaliveActionChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlTimeStamp, sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlNoKeepalive }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorGlobalNotification 3 }
sleFaultMonitorDaemonConfig OBJECT IDENTIFIER ::= { sleFaultMonitor 2 }
sleFaultMonitorDaemonTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleFaultMonitorDaemonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonConfig 1 }
sleFaultMonitorDaemonEntry OBJECT-TYPE
SYNTAX SleFaultMonitorDaemonEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleFaultMonitorDaemonPid }
::= { sleFaultMonitorDaemonTable 1 }
SleFaultMonitorDaemonEntry ::=
SEQUENCE {
sleFaultMonitorDaemonName
OCTET STRING,
sleFaultMonitorDaemonPid
Integer32,
sleFaultMonitorDaemonAdminStatus
INTEGER,
sleFaultMonitorDaemonCrashAction
INTEGER,
sleFaultMonitorDaemonTimeoutAction
INTEGER,
sleFaultMonitorDaemonThreshold
Integer32,
sleFaultMonitorDaemonThresholded
Integer32,
sleFaultMonitorDaemonStartupThresholded
Integer32,
sleFaultMonitorDaemonWatchdogAdminStatus
INTEGER,
sleFaultMonitorDaemonWatchdogThreshold
Integer32,
sleFaultMonitorDaemonWatchdogCount
Integer32
}
sleFaultMonitorDaemonName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daemon name"
::= { sleFaultMonitorDaemonEntry 1 }
sleFaultMonitorDaemonPid OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daemon PID
"
::= { sleFaultMonitorDaemonEntry 2 }
sleFaultMonitorDaemonAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Daemon Inspection admin status.
"
::= { sleFaultMonitorDaemonEntry 3 }
sleFaultMonitorDaemonCrashAction OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
restart(2),
switchover(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate action type when daemon is crashed
"
::= { sleFaultMonitorDaemonEntry 4 }
sleFaultMonitorDaemonTimeoutAction OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
restart(2),
switchover(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate action type when daemon is timeout
"
::= { sleFaultMonitorDaemonEntry 5 }
sleFaultMonitorDaemonThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate fault admin threshold.
"
::= { sleFaultMonitorDaemonEntry 6 }
sleFaultMonitorDaemonThresholded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate fault accumulated threshold.
"
::= { sleFaultMonitorDaemonEntry 7 }
sleFaultMonitorDaemonStartupThresholded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonEntry 8 }
sleFaultMonitorDaemonWatchdogAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate whether connect watchdog or not
"
::= { sleFaultMonitorDaemonEntry 9 }
sleFaultMonitorDaemonWatchdogThreshold OBJECT-TYPE
SYNTAX Integer32 (5..60)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate watchdog threshold of daemon.
"
::= { sleFaultMonitorDaemonEntry 10 }
sleFaultMonitorDaemonWatchdogCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate watchdog accumulated count.
"
::= { sleFaultMonitorDaemonEntry 11 }
sleFaultMonitorDaemonControl OBJECT IDENTIFIER ::= { sleFaultMonitorDaemonConfig 2 }
sleFaultMonitorDaemonControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setDaemonAdminStatus(1),
setDaemonFaultAction(2),
setDaemonThreshold(3),
setDaemonWatchdog(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { sleFaultMonitorDaemonControl 1 }
sleFaultMonitorDaemonControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleFaultMonitorDaemonControl 2 }
sleFaultMonitorDaemonControlTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleFaultMonitorDaemonControl 3 }
sleFaultMonitorDaemonControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleFaultMonitorDaemonControl 4 }
sleFaultMonitorDaemonControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleFaultMonitorDaemonControl 5 }
sleFaultMonitorDaemonControlName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonControl 6 }
sleFaultMonitorDaemonControlAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"daemon Inspection value.
unit : sec, default : 5
"
::= { sleFaultMonitorDaemonControl 7 }
sleFaultMonitorDaemonControlCrashAction OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
restart(2),
switchover(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"daemon startup threshold value.
unit : sec, default : 100
"
::= { sleFaultMonitorDaemonControl 8 }
sleFaultMonitorDaemonControlTimeoutAction OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
restart(2),
switchover(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate action when don't receive keepalive msg.
"
::= { sleFaultMonitorDaemonControl 9 }
sleFaultMonitorDaemonControlThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonControl 10 }
sleFaultMonitorDaemonControlThreshed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonControl 11 }
sleFaultMonitorDaemonControlStartupThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonControl 12 }
sleFaultMonitorDaemonControlWatchdogAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonControl 13 }
sleFaultMonitorDaemonControlWatchdogThreshold OBJECT-TYPE
SYNTAX Integer32 (5..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonControl 14 }
sleFaultMonitorDaemonNotification OBJECT IDENTIFIER ::= { sleFaultMonitorDaemonConfig 4 }
setFaultMonitorDaemonAdminStatusChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlAdminStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonNotification 1 }
setFaultMonitorDaemonFaultActionChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlCrashAction, sleFaultMonitorDaemonControlTimeoutAction
}
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonNotification 2 }
setFaultMonitorDaemonThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonNotification 3 }
setFaultMonitorDaemonWatchdogchanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult, sleFaultMonitorDaemonControlWatchdogAdminStatus, sleFaultMonitorDaemonControlWatchdogThreshold
}
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorDaemonNotification 4 }
sleFaultMonitor2pointsLinear OBJECT IDENTIFIER ::= { sleFaultMonitor 3 }
sleFaultMonitor2pointsLinearInfo OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 1 }
sleFaultMonitor2pointsLinearAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate whether 2-points-linear monitoring is enabled or not
"
::= { sleFaultMonitor2pointsLinearInfo 1 }
sleFaultMonitor2pointsLinearInterval OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate 2-points-linear monitoring interval
default : 5, unit : sec
"
::= { sleFaultMonitor2pointsLinearInfo 2 }
sleFaultMonitor2pointsLinearThreshold OBJECT-TYPE
SYNTAX Integer32 (1..60)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate 2-points-linear monitoring threshold
default : 8 times
"
::= { sleFaultMonitor2pointsLinearInfo 3 }
sleFaultMonitor2pointsLinearControl OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 2 }
sleFaultMonitor2pointsLinearControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
set2PointsLinearAdminStatus(1),
set2PointsLinearInterval(2),
set2PointsLinearThreshold(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { sleFaultMonitor2pointsLinearControl 1 }
sleFaultMonitor2pointsLinearControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleFaultMonitor2pointsLinearControl 2 }
sleFaultMonitor2pointsLinearControlTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleFaultMonitor2pointsLinearControl 3 }
sleFaultMonitor2pointsLinearControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleFaultMonitor2pointsLinearControl 4 }
sleFaultMonitor2pointsLinearControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleFaultMonitor2pointsLinearControl 5 }
sleFaultMonitor2pointsLinearControlAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { sleFaultMonitor2pointsLinearControl 6 }
sleFaultMonitor2PonitsLinearControlInterval OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate 2-points-linear monitoring interval
default : 5, unit : sec"
::= { sleFaultMonitor2pointsLinearControl 7 }
sleFaultMonitor2PointsLinearControlThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate 2-points-linear monitoring threshold
default : 8 times
"
::= { sleFaultMonitor2pointsLinearControl 8 }
sleFaultMonitor2pointsLinearNotification OBJECT IDENTIFIER ::= { sleFaultMonitor2pointsLinear 3 }
sleFaultMonitor2PointsLinearAdminStatusChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2pointsLinearControlAdminStatus }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitor2pointsLinearNotification 1 }
sleFaultMonitor2PointsLinearIntervalChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2PonitsLinearControlInterval }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitor2pointsLinearNotification 2 }
sleFaultMonitor2PointsLinearThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitor2pointsLinearControlRequest, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2PointsLinearControlThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitor2pointsLinearNotification 3 }
sleFaultMonitorRHM OBJECT IDENTIFIER ::= { sleFaultMonitor 4 }
sleFaultMonitorRHMInfo OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 1 }
sleFaultMonitorRHMAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RHM admin status"
::= { sleFaultMonitorRHMInfo 1 }
sleFaultMonitorRHMActionType OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
switchover(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RHM action type
"
::= { sleFaultMonitorRHMInfo 2 }
sleFaultMonitorRHMActionThreshold OBJECT-TYPE
SYNTAX Integer32 (5..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RHM action threshold
"
::= { sleFaultMonitorRHMInfo 3 }
sleFaultMonitorRHMRebootThreshold OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RHM reboot threshold"
::= { sleFaultMonitorRHMInfo 4 }
sleFaultMonitorRHMRecoveryTime OBJECT-TYPE
SYNTAX Integer32 (10..14400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RHM recovery time"
::= { sleFaultMonitorRHMInfo 5 }
sleFaultMonitorRHMFaultCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RHM fault counter"
::= { sleFaultMonitorRHMInfo 6 }
sleFaultMonitorRHMRebootCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RHM reboot counter"
::= { sleFaultMonitorRHMInfo 7 }
sleFaultMonitorRHMInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMInfo 8 }
sleFaultMonitorRHMLiveThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMInfo 9 }
sleFaultMonitorRHMHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF SleFaultMonitorRHMHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHM 2 }
sleFaultMonitorRHMHostEntry OBJECT-TYPE
SYNTAX SleFaultMonitorRHMHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sleFaultMonitorRHMHostAddr }
::= { sleFaultMonitorRHMHostTable 1 }
SleFaultMonitorRHMHostEntry ::=
SEQUENCE {
sleFaultMonitorRHMHostAddr
IpAddress
}
sleFaultMonitorRHMHostAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The target host or gateway address of RHM
"
::= { sleFaultMonitorRHMHostEntry 1 }
sleFaultMonitorRHMControl OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 3 }
sleFaultMonitorRHMControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setRHMStatus(1),
setRHMActionThreshold(2),
setRHMRebootThreshold(3),
setInterval(4),
setLiveThreshold(5),
clearRHMHost(6),
setRHMHost(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { sleFaultMonitorRHMControl 1 }
sleFaultMonitorRHMControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The status of a control request. "
::= { sleFaultMonitorRHMControl 2 }
sleFaultMonitorRHMControlTimer OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The maximum wait time for the manager for command ending.
For long running commands.
The manager reads this value from the DSLAM. "
::= { sleFaultMonitorRHMControl 3 }
sleFaultMonitorRHMControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The time stamp of the last command (end of command). "
::= { sleFaultMonitorRHMControl 4 }
sleFaultMonitorRHMControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The result of the last user command. "
::= { sleFaultMonitorRHMControl 5 }
sleFaultMonitorRHMControlAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
::= { sleFaultMonitorRHMControl 6 }
sleFaultMonitorRHMControlActionType OBJECT-TYPE
SYNTAX INTEGER
{
log(1),
switchover(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate 2-points-linear monitoring interval
default : 5, unit : sec"
::= { sleFaultMonitorRHMControl 7 }
sleFaultMonitorRHMControlActionThreshold OBJECT-TYPE
SYNTAX Integer32 (5..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RHM reboot threshold"
::= { sleFaultMonitorRHMControl 8 }
sleFaultMonitorRHMControlRebootThreshold OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RHM reboot threshold"
::= { sleFaultMonitorRHMControl 9 }
sleFaultMonitorRHMControlRecoveryTime OBJECT-TYPE
SYNTAX Integer32 (10..14400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RHM recovery time"
::= { sleFaultMonitorRHMControl 10 }
sleFaultMonitorRHMControlInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMControl 11 }
sleFaultMonitorRHMControlLiveThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMControl 12 }
sleFaultMonitorRHMControlHostAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMControl 13 }
sleFaultMonitorRHMNotification OBJECT IDENTIFIER ::= { sleFaultMonitorRHM 4 }
setRHMStatusChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlAdminStatus, sleFaultMonitorRHMControlActionType
}
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMNotification 1 }
setRHMActionThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlActionThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMNotification 2 }
setRHMRebootThresholdChanged NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMNotification 3 }
setRHMHostAdded NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMNotification 4 }
setRHMHostCleared NOTIFICATION-TYPE
OBJECTS { sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult, sleFaultMonitorRHMControlRebootThreshold }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMonitorRHMNotification 5 }
sle2EthernetCfm OBJECT IDENTIFIER ::= { sleFaultMgmt 17 }
sle2EthernetCfmBase OBJECT IDENTIFIER ::= { sle2EthernetCfm 1 }
sle2EthCfmBaseGroup OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 1 }
sle2EthCfmEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseGroup 1 }
sle2EthCfmLmmFrameCountSimStatus OBJECT-TYPE
SYNTAX INTEGER
{
stop(0),
start(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseGroup 2 }
sle2EthCfmBaseControl OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 2 }
sle2EthCfmControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setCfmEnable(1),
setCfmLmmSimulator(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseControl 1 }
sle2EthCfmControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseControl 2 }
sle2EthCfmControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseControl 3 }
sle2EthCfmControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseControl 4 }
sle2EthCfmControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseControl 5 }
sle2EthCfmControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseControl 6 }
sle2EthCfmControlLmmFrameCountSimStatus OBJECT-TYPE
SYNTAX INTEGER
{
stop(0),
start(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseControl 7 }
sle2EthCfmBaseNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmBase 3 }
sle2EthCfmEnableChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmControlRequest, sle2EthCfmControlReqResult, sle2EthCfmControlTimeStamp, sle2EthCfmEnable }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseNotification 1 }
sle2EthCfmLmmFrameCountSimulatorChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmControlRequest, sle2EthCfmControlReqResult, sle2EthCfmControlTimeStamp, sle2EthCfmLmmFrameCountSimStatus }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBaseNotification 2 }
sle2EthernetCfmBridge OBJECT IDENTIFIER ::= { sle2EthernetCfm 2 }
sle2EthCfmBridgeTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmBridgeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmBridge 1 }
sle2EthCfmBridgeEntry OBJECT-TYPE
SYNTAX Sle2EthCfmBridgeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId }
::= { sle2EthCfmBridgeTable 1 }
Sle2EthCfmBridgeEntry ::=
SEQUENCE {
sle2EthCfmBridgeId
Integer32,
sle2EthCfmBridgeDefaultMdLevel
Integer32,
sle2EthCfmBridgeDefaultMepId
Integer32,
sle2EthCfmBridgeAutomatic
INTEGER,
sle2EthCfmBridgeConfigDefaultMdLevel
Integer32,
sle2EthCfmBridgeConfigDefaultMdMipCreation
INTEGER,
sle2EthCfmBridgeLtrCacheEnable
INTEGER,
sle2EthCfmBridgeLtrCacheSize
Integer32
}
sle2EthCfmBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 1 }
sle2EthCfmBridgeDefaultMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 2 }
sle2EthCfmBridgeDefaultMepId OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 3 }
sle2EthCfmBridgeAutomatic OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 4 }
sle2EthCfmBridgeConfigDefaultMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 5 }
sle2EthCfmBridgeConfigDefaultMdMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 6 }
sle2EthCfmBridgeLtrCacheEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 7 }
sle2EthCfmBridgeLtrCacheSize OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeEntry 8 }
sle2EthCfmBridgeControl OBJECT IDENTIFIER ::= { sle2EthernetCfmBridge 2 }
sle2EthCfmBridgeControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setCfmBridgeProfile(1),
setCfmBridgeLtrCache(2),
clearCfmBridgeLtrChace(3),
setCfmBridgeAutomatic(4),
setCfmBridgeConfigDefaultMdLevel(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 1 }
sle2EthCfmBridgeControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 2 }
sle2EthCfmBridgeControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 3 }
sle2EthCfmBridgeControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 4 }
sle2EthCfmBridgeControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 5 }
sle2EthCfmBridgeControlId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 6 }
sle2EthCfmBridgeControlDefaultMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 7 }
sle2EthCfmBridgeControlDefaultMepId OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 8 }
sle2EthCfmBridgeControlAutomatic OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 9 }
sle2EthCfmBridgeControlConfigDefaultMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 10 }
sle2EthCfmBridgeControlConfigDefaultMdMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 11 }
sle2EthCfmBridgeConntrolLtrCacheEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 12 }
sle2EthCfmBridgeControlLtrCacheSize OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeControl 13 }
sle2EthCfmBridgeNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmBridge 3 }
setCfmBridgeProfile NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeDefaultMdLevel,
sle2EthCfmBridgeDefaultMepId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeNotification 1 }
setCfmBridgeLtrCacheEnable NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeLtrCacheSize,
sle2EthCfmBridgeLtrCacheEnable }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeNotification 2 }
clearCfmBridgeLtrCache NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeNotification 3 }
setCfmBridgeAutomatic NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeAutomatic
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeNotification 4 }
setCfmBridgeConfigDefaultMdLevel NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmBridgeConfigDefaultMdLevel,
sle2EthCfmBridgeConfigDefaultMdMipCreation }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmBridgeNotification 5 }
sle2EhternetCfmVlan OBJECT IDENTIFIER ::= { sle2EthernetCfm 3 }
sle2EthernetCfmVlanConfig OBJECT IDENTIFIER ::= { sle2EhternetCfmVlan 1 }
sle2EthCfmVlanConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmVlanConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmVlanConfig 1 }
sle2EthCfmVlanConfigEntry OBJECT-TYPE
SYNTAX Sle2EthCfmVlanConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmVlanConfigPrimaryVid, sle2EthCfmVlanConfigSecondaryVid }
::= { sle2EthCfmVlanConfigTable 1 }
Sle2EthCfmVlanConfigEntry ::=
SEQUENCE {
sle2EthCfmVlanConfigPrimaryVid
Integer32,
sle2EthCfmVlanConfigSecondaryVid
Integer32,
sle2EthCfmVlanConfigSecondaryBridgeId
Integer32
}
sle2EthCfmVlanConfigPrimaryVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigEntry 1 }
sle2EthCfmVlanConfigSecondaryVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigEntry 2 }
sle2EthCfmVlanConfigSecondaryBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigEntry 3 }
sle2EthCfmVlanConfigControl OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanConfig 2 }
sle2EthCfmVlanConfigControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
addCfmVlanConfVid(1),
delCfmVlanConfVid(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 1 }
sle2EthCfmVlanConfigControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 2 }
sle2EthCfmVlanConfigControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 3 }
sle2EthCfmVlanConfigControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 4 }
sle2EthCfmVlanConfigControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 5 }
sle2EthCfmVlanConfigControlPrimaryBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 6 }
sle2EthCfmVlanConfigControlPrimaryVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 7 }
sle2EthCfmVlanConfigControlSecondaryBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 8 }
sle2EthCfmVlanConfigControlSecondaryVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigControl 9 }
sle2EthCfmVlanConfigNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanConfig 3 }
addCfmVlanConfVid NOTIFICATION-TYPE
OBJECTS { sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmVlanConfigPrimaryVid,
sle2EthCfmVlanConfigSecondaryVid, sle2EthCfmVlanConfigSecondaryBridgeId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigNotification 1 }
delCfmVlanConfVid NOTIFICATION-TYPE
OBJECTS { sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmVlanConfigControlPrimaryBridgeId, sle2EthCfmVlanConfigControlPrimaryVid,
sle2EthCfmVlanConfigControlSecondaryBridgeId, sle2EthCfmVlanConfigControlSecondaryVid }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanConfigNotification 2 }
sle2EthernetCfmVlanInfo OBJECT IDENTIFIER ::= { sle2EhternetCfmVlan 2 }
sle2EthCfmVlanInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmVlanInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmVlanInfo 1 }
sle2EthCfmVlanInfoEntry OBJECT-TYPE
SYNTAX Sle2EthCfmVlanInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmVlanInfoVid }
::= { sle2EthCfmVlanInfoTable 1 }
Sle2EthCfmVlanInfoEntry ::=
SEQUENCE {
sle2EthCfmVlanInfoVid
Integer32,
sle2EthCfmVlanInfoPriority
Integer32
}
sle2EthCfmVlanInfoVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoEntry 1 }
sle2EthCfmVlanInfoPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoEntry 2 }
sle2EthCfmVlanInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanInfo 2 }
sle2EthCfmVlanInfoControlRequest OBJECT-TYPE
SYNTAX INTEGER { setCfmVlanPriority(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 1 }
sle2EthCfmVlanInfoControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 2 }
sle2EthCfmVlanInfoControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 3 }
sle2EthCfmVlanInfoControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 4 }
sle2EthCfmVlanInfoControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 5 }
sle2EthCfmVlanInfoControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 6 }
sle2EthCfmVlanInfoControlVid OBJECT-TYPE
SYNTAX Integer32 (2..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 7 }
sle2EthCfmVlanInfoControlPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoControl 8 }
sle2EthCfmVlanInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmVlanInfo 3 }
sle2EthCfmVlanPriorityChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmVlanInfoControlRequest, sle2EthCfmVlanInfoControlReqResult, sle2EthCfmVlanInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmVlanInfoVid,
sle2EthCfmVlanInfoPriority }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmVlanInfoNotification 1 }
sle2EthernetCfmDefMdLevelEntry OBJECT IDENTIFIER ::= { sle2EthernetCfm 4 }
sle2EthCfmDefMdLevelEntryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmDefMdLevelEntryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmDefMdLevelEntry 1 }
sle2EthCfmDefMdLevelEntryEntry OBJECT-TYPE
SYNTAX Sle2EthCfmDefMdLevelEntryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmDefMdLevelEntryVid }
::= { sle2EthCfmDefMdLevelEntryTable 1 }
Sle2EthCfmDefMdLevelEntryEntry ::=
SEQUENCE {
sle2EthCfmDefMdLevelEntryVid
Integer32,
sle2EthCfmDefMdLevelEntryLevel
Integer32,
sle2EthCfmDefMdLevelEntryMipCreation
INTEGER
}
sle2EthCfmDefMdLevelEntryVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryEntry 1 }
sle2EthCfmDefMdLevelEntryLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryEntry 2 }
sle2EthCfmDefMdLevelEntryMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryEntry 3 }
sle2EthCfmDefMdLevelEntryControl OBJECT IDENTIFIER ::= { sle2EthernetCfmDefMdLevelEntry 2 }
sle2EthCfmDefMdLevelEntryControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setCfmDefMdLevelEntry(1),
clearCfmDefMdLevelEntry(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 1 }
sle2EthCfmDefMdLevelEntryControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 2 }
sle2EthCfmDefMdLevelEntryControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 3 }
sle2EthCfmDefMdLevelEntryControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 4 }
sle2EthCfmDefMdLevelEntryControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 5 }
sle2EthCfmDefMdLevelEntryControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 6 }
sle2EthCfmDefMdLevelEntryControlVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 7 }
sle2EthCfmDefMdLevelEntryControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 8 }
sle2EthCfmDefMdLevelEntryControlMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryControl 9 }
sle2EthCfmDefMdLevelEntryNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmDefMdLevelEntry 3 }
sle2EthCfmDefMdLevelEntryChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmDefMdLevelEntryControlRequest, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmDefMdLevelEntryVid,
sle2EthCfmDefMdLevelEntryLevel, sle2EthCfmDefMdLevelEntryMipCreation }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryNotification 1 }
sle2EthCfmDefMdLevelEntryCleared NOTIFICATION-TYPE
OBJECTS { sle2EthCfmDefMdLevelEntryControlRequest, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmDefMdLevelEntryControlBridgeId, sle2EthCfmDefMdLevelEntryControlVid,
sle2EthCfmDefMdLevelEntryControlLevel, sle2EthCfmDefMdLevelEntryControlMipCreation }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmDefMdLevelEntryNotification 2 }
sle2EthernetCfmMd OBJECT IDENTIFIER ::= { sle2EthernetCfm 5 }
sle2EthCfmMdTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmMd 1 }
sle2EthCfmMdEntry OBJECT-TYPE
SYNTAX Sle2EthCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName }
::= { sle2EthCfmMdTable 1 }
Sle2EthCfmMdEntry ::=
SEQUENCE {
sle2EthCfmMdName
OCTET STRING,
sle2EthCfmMdType
INTEGER,
sle2EthCfmMdLevel
Integer32,
sle2EthCfmMdMipCreation
INTEGER
}
sle2EthCfmMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdEntry 1 }
sle2EthCfmMdType OBJECT-TYPE
SYNTAX INTEGER
{
noName(1),
dnsBased(2),
mac(3),
characterString(4),
ituT(32)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdEntry 2 }
sle2EthCfmMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdEntry 3 }
sle2EthCfmMdMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdEntry 4 }
sle2EthCfmMdControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMd 2 }
sle2EthCfmMdControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmMd(1),
destoryCfmMd(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 1 }
sle2EthCfmMdControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 2 }
sle2EthCfmMdControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 3 }
sle2EthCfmMdControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 4 }
sle2EthCfmMdControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 5 }
sle2EthCfmMdControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 6 }
sle2EthCfmMdControlType OBJECT-TYPE
SYNTAX INTEGER
{
noName(1),
dnsBased(2),
mac(3),
characterString(4),
ituT(32)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 7 }
sle2EthCfmMdControlName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 8 }
sle2EthCfmMdControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 9 }
sle2EthCfmMdControlMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdControl 10 }
sle2EthCfmMdNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMd 3 }
sle2EthCfmMdCreated NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMdControlRequest, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMdType, sle2EthCfmMdLevel, sle2EthCfmMdMipCreation }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdNotification 1 }
sle2EthCfmMdDestoryed NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMdControlRequest, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlTimeStamp, sle2EthCfmMdControlBridgeId, sle2EthCfmMdControlName,
sle2EthCfmMdControlLevel, sle2EthCfmMdControlMipCreation }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMdNotification 2 }
sle2EthernetCfmMa OBJECT IDENTIFIER ::= { sle2EthernetCfm 6 }
sle2EthCfmMaTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmMa 1 }
sle2EthCfmMaEntry OBJECT-TYPE
SYNTAX Sle2EthCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaName }
::= { sle2EthCfmMaTable 1 }
Sle2EthCfmMaEntry ::=
SEQUENCE {
sle2EthCfmMaName
OCTET STRING,
sle2EthCfmMaVid
Integer32,
sle2EthCfmMaType
INTEGER,
sle2EthCfmMaMipCreation
INTEGER,
sle2EthCfmMaCcInterval
Integer32,
sle2EthCfmMaElmi
INTEGER,
sle2EthCfmMaConnectivityStatus
INTEGER,
sle2EthCfmMaConfiguredRmepCount
Integer32,
sle2EthCfmMaConvergedRmepCount
Integer32
}
sle2EthCfmMaName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 1 }
sle2EthCfmMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 2 }
sle2EthCfmMaType OBJECT-TYPE
SYNTAX INTEGER
{
primaryVid(1),
string(2),
integer(3),
vpnId(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 3 }
sle2EthCfmMaMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3),
defer(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 4 }
sle2EthCfmMaCcInterval OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 5 }
sle2EthCfmMaElmi OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 6 }
sle2EthCfmMaConnectivityStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknow(1),
active(2),
partiallyActive(3),
notActive(4),
error(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 7 }
sle2EthCfmMaConfiguredRmepCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 8 }
sle2EthCfmMaConvergedRmepCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaEntry 9 }
sle2EthCfmMaControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMa 2 }
sle2EthCfmMaControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmMa(1),
destoryCfmMa(2),
setCfmCcInterval(3),
setCfmElmi(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 1 }
sle2EthCfmMaControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 2 }
sle2EthCfmMaControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 3 }
sle2EthCfmMaControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 4 }
sle2EthCfmMaControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 5 }
sle2EthCfmMaControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 6 }
sle2EthCfmMaControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 7 }
sle2EthCfmMaControlName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 8 }
sle2EthCfmMaControlType OBJECT-TYPE
SYNTAX INTEGER
{
primaryVid(1),
string(2),
integer(3),
vpnId(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 9 }
sle2EthCfmMaControlVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 10 }
sle2EthCfmMaControlMipCreation OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
default(2),
explicit(3),
defer(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 11 }
sle2EthCfmMaControlCcmInterval OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 12 }
sle2EthCfmMaControlElmi OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaControl 13 }
sle2EthCfmMaNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMa 3 }
sle2EthCfmMaCreated NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaName, sle2EthCfmMaVid, sle2EthCfmMaType, sle2EthCfmMaMipCreation }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaNotification 1 }
sle2EthCfmMaDestoryed NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmMaControlBridgeId, sle2EthCfmMaControlMdName,
sle2EthCfmMaControlName, sle2EthCfmMaControlVid, sle2EthCfmMaControlMipCreation }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaNotification 2 }
sle2EthCfmCcIntervalChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMaCcInterval }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaNotification 3 }
sle2EthCfmElmiChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMaControlRequest, sle2EthCfmMaControlReqResult, sle2EthCfmMaControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaName, sle2EthCfmMaElmi }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMaNotification 4 }
sle2EthernetCfmMep OBJECT IDENTIFIER ::= { sle2EthernetCfm 7 }
sle2EthernetCfmMepInfo OBJECT IDENTIFIER ::= { sle2EthernetCfmMep 1 }
sle2EthCfmMepInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmMepInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmMepInfo 1 }
sle2EthCfmMepInfoEntry OBJECT-TYPE
SYNTAX Sle2EthCfmMepInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
::= { sle2EthCfmMepInfoTable 1 }
Sle2EthCfmMepInfoEntry ::=
SEQUENCE {
sle2EthCfmMepInfoId
Integer32,
sle2EthCfmMepInfoIfindex
Integer32,
sle2EthCfmMepInfoLocalVid
Integer32,
sle2EthCfmMepInfoDirection
INTEGER,
sle2EthCfmMepInfoActive
INTEGER,
sle2EthCfmMepInfoUNI
INTEGER,
sle2EthCfmMepInfoCcmStatus
INTEGER,
sle2EthCfmMepInfoCcmType
INTEGER,
sle2EthCfmMepInfoCcmRmepId
Integer32,
sle2EthCfmMepInfoLocalMacAddr
OCTET STRING,
sle2EthCfmMepInfoRdi
INTEGER,
sle2EthCfmMepInfoService
INTEGER,
sle2EthCfmMepInfoLckLevel
Integer32,
sle2EthCfmMepInfoDlmState
INTEGER,
sle2EthCfmMepInfoDlmRmepId
Integer32,
sle2EthCfmMepInfoConnectivityStatus
INTEGER,
sle2EthCfmMepInfoInterval
Integer32
}
sle2EthCfmMepInfoId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 1 }
sle2EthCfmMepInfoIfindex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 2 }
sle2EthCfmMepInfoLocalVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 3 }
sle2EthCfmMepInfoDirection OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 4 }
sle2EthCfmMepInfoActive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 5 }
sle2EthCfmMepInfoUNI OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 6 }
sle2EthCfmMepInfoCcmStatus OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 7 }
sle2EthCfmMepInfoCcmType OBJECT-TYPE
SYNTAX INTEGER
{
unicast(1),
multicast(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 8 }
sle2EthCfmMepInfoCcmRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 9 }
sle2EthCfmMepInfoLocalMacAddr OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 10 }
sle2EthCfmMepInfoRdi OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 11 }
sle2EthCfmMepInfoService OBJECT-TYPE
SYNTAX INTEGER
{
inService(0),
outOfService(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 12 }
sle2EthCfmMepInfoLckLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 13 }
sle2EthCfmMepInfoDlmState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 14 }
sle2EthCfmMepInfoDlmRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 15 }
sle2EthCfmMepInfoConnectivityStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
isolated(1),
fully(2),
partially(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 16 }
sle2EthCfmMepInfoInterval OBJECT-TYPE
SYNTAX Integer32 (1..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoEntry 17 }
sle2EthCfmMepInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMepInfo 2 }
sle2EthCfmMepInfoControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createEthCfmMep(1),
destoryEthCfmMep(2),
setEthCfmCcEnable(3),
setEthCfmService(4),
setEthCfmDlmm(5),
tarnsmitUnicastTst(6),
tarnsmitMulticastTst(7),
transmitUnicastLm(8),
transmitMulticastLm(9),
transmitUnicastDm(10),
transmitMulticastDm(11),
receive1Dm(12),
transmitTm(13),
receiveTm(14),
transmitExm(15),
transmitVsm(16),
transmitMcc(17)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 1 }
sle2EthCfmMepInfoControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 2 }
sle2EthCfmMepInfoControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 3 }
sle2EthCfmMepInfoControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 4 }
sle2EthCfmMepInfoControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 5 }
sle2EthCfmMepInfoControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 6 }
sle2EthCfmMepInfoControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 7 }
sle2EthCfmMepInfoControlMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 8 }
sle2EthCfmMepInfoControlIfindex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 9 }
sle2EthCfmMepInfoControlId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 10 }
sle2EthCfmMepInfoControlLocalVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 11 }
sle2EthCfmMepInfoControlMepDirection OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 12 }
sle2EthCfmMepInfoControlActive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 13 }
sle2EthCfmMepInfoControlUNI OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 14 }
sle2EthCfmMepInfoControlCcmStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 15 }
sle2EthCfmMepInfoControlFrameType OBJECT-TYPE
SYNTAX INTEGER
{
unicast(1),
multicast(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 16 }
sle2EthCfmMepInfoControlRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 17 }
sle2EthCfmMepInfoControlService OBJECT-TYPE
SYNTAX INTEGER
{
inService(0),
outOfService(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 18 }
sle2EthCfmMepInfoControlDlmState OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 19 }
sle2EthCfmMepInfoControlLckLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 20 }
sle2EthCfmMepInfoControlTstPattern OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 21 }
sle2EthCfmMepInfoControlTstRecursive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 22 }
sle2EthCfmMepInfoControlDuration OBJECT-TYPE
SYNTAX Integer32 (5..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 23 }
sle2EthCfmMepInfoControlTstTxInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 24 }
sle2EthCfmMepInfoControlTstLckInterval OBJECT-TYPE
SYNTAX Integer32 (1 | 60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 25 }
sle2EthCfmMepInfoControlLckRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoControl 26 }
sle2EthCfmMepInfoControlInterval OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates interval value.
1: 100ms
2: 10ms
3: 1s
4: 10s
"
::= { sle2EthCfmMepInfoControl 27 }
sle2EthCfmMepInfoControlTransMode OBJECT-TYPE
SYNTAX INTEGER
{
oneDm(1),
dvm(2),
dmm(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the transmit mode."
::= { sle2EthCfmMepInfoControl 28 }
sle2EthCfmMepInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMepInfo 3 }
sle2EthCfmMepCreated NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoLocalVid, sle2EthCfmMepInfoDirection,
sle2EthCfmMepInfoActive, sle2EthCfmMepInfoUNI }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 1 }
sle2EthCfmMepDestory NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlIfindex, sle2EthCfmMepInfoControlMepDirection, sle2EthCfmMepInfoControlLocalVid
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 2 }
sle2EthCfmCcEnableChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoCcmFrameType, sle2EthCfmMepInfoCcmStatus, sle2EthCfmMepInfoCcmRmepId
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 3 }
sle2EthCfmServiceChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoService, sle2EthCfmMepInfoLckLevel }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 4 }
sle2EthCfmDualEndLmmChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoDlmState, sle2EthCfmMepInfoDlmRmepId
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 5 }
sle2EthCfmTransmitUnicastTstFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive,
sle2EthCfmMepInfoControlTstTxInterval, sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepInfoControlDuration
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 6 }
sle2EthCfmTransmitMulticastTstFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive, sle2EthCfmMepInfoControlTstTxInterval,
sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepInfoControlDuration }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 7 }
sle2EthCfmTransmitUnicastLmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 8 }
sle2EthCfmTransmitMulticastLmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 9 }
sle2EthCfmTransmitUnicastDmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTransMode, sle2EthCfmMepInfoControlRmepId, sle2EthCfmMepInfoControlDuration,
sle2EthCfmMepInfoControlInterval }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 10 }
sle2EthCfmTransmitMuliticastDmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlTransMode, sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 11 }
sle2EthCfmReceive1DmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 12 }
sle2EthCfmTransmitTmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 13 }
sle2EthCfmReceiveTmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlDuration }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 14 }
sle2EthCfmTransmitExmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 15 }
sle2EthCfmTransmitVsmFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlRmepId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 16 }
sle2EthCfmTransmitMccFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlRmepId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepInfoNotification 17 }
sle2EthernetCfmMepAttributs OBJECT IDENTIFIER ::= { sle2EthernetCfmMep 2 }
sle2EthCfmMepAttrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmMepAttrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmMepAttributs 1 }
sle2EthCfmMepAttrEntry OBJECT-TYPE
SYNTAX Sle2EthCfmMepAttrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
::= { sle2EthCfmMepAttrTable 1 }
Sle2EthCfmMepAttrEntry ::=
SEQUENCE {
sle2EthCfmMepAttrActive
INTEGER,
sle2EthCfmMepAttrCcmLtmPriority
Integer32,
sle2EthCfmMepAttrLowPrDef
INTEGER,
sle2EthCfmMepAttrFngAlarmTime
Integer32,
sle2EthCfmMepAttrResetFngTime
Integer32,
sle2EthCfmMepAttrCcmLtmFlag
Integer32,
sle2EthCfmMepAttrTxLtmTargetMac
OCTET STRING,
sle2EthCfmMepAttrTxLtmTargetMepId
Integer32,
sle2EthCfmMepAttrTxLtmTargetIsMepId
INTEGER,
sle2EthCfmMepAttrTxLtmTtl
Integer32,
sle2EthCfmMepAttrTxLtmEgressId
OCTET STRING,
sle2EthCfmMepAttrTxLbmStatus
INTEGER,
sle2EthCfmMepAttrTxLbmDestMac
OCTET STRING,
sle2EthCfmMepAttrTxLbmDestMepId
Integer32,
sle2EthCfmMepAttrTxLbmDestIsMepId
INTEGER,
sle2EthCfmMepAttrTxLbmMessages
Integer32,
sle2EthCfmMepAttrTxLbmDataTlv
OCTET STRING,
sle2EthCfmMepAttrTxLbmVlanPriority
Integer32,
sle2EthCfmMepAttrTxLbmVlanDropEnable
INTEGER,
sle2EthCfmMepAttrTxLbmTimeOut
Integer32,
sle2EthCfmMepAttrLbrTimeOut
Integer32
}
sle2EthCfmMepAttrActive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 1 }
sle2EthCfmMepAttrCcmLtmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 2 }
sle2EthCfmMepAttrLowPrDef OBJECT-TYPE
SYNTAX INTEGER
{
allDef(1),
macRemErrXcon(2),
remErrXcon(3),
errXcon(4),
xcon(5),
noXcon(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 3 }
sle2EthCfmMepAttrFngAlarmTime OBJECT-TYPE
SYNTAX Integer32 (250..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 4 }
sle2EthCfmMepAttrResetFngTime OBJECT-TYPE
SYNTAX Integer32 (250..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 5 }
sle2EthCfmMepAttrCcmLtmFlag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 6 }
sle2EthCfmMepAttrTxLtmTargetMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 7 }
sle2EthCfmMepAttrTxLtmTargetMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 8 }
sle2EthCfmMepAttrTxLtmTargetIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 9 }
sle2EthCfmMepAttrTxLtmTtl OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 10 }
sle2EthCfmMepAttrTxLtmEgressId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 11 }
sle2EthCfmMepAttrTxLbmStatus OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 12 }
sle2EthCfmMepAttrTxLbmDestMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 13 }
sle2EthCfmMepAttrTxLbmDestMepId OBJECT-TYPE
SYNTAX Integer32 (0..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 14 }
sle2EthCfmMepAttrTxLbmDestIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 15 }
sle2EthCfmMepAttrTxLbmMessages OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 16 }
sle2EthCfmMepAttrTxLbmDataTlv OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 17 }
sle2EthCfmMepAttrTxLbmVlanPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 18 }
sle2EthCfmMepAttrTxLbmVlanDropEnable OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 19 }
sle2EthCfmMepAttrTxLbmTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 20 }
sle2EthCfmMepAttrLbrTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrEntry 21 }
sle2EthCfmMepAttrControl OBJECT IDENTIFIER ::= { sle2EthernetCfmMepAttributs 2 }
sle2EthCfmMepAttrControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setCfmFaultProfile(1),
setCfmTxLtmProfile(2),
setCfmTxLbmProfile(3),
clearAllCfmMepAttuributes(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 1 }
sle2EthCfmMepAttrControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 2 }
sle2EthCfmMepAttrControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 3 }
sle2EthCfmMepAttrControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 4 }
sle2EthCfmMepAttrControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 5 }
sle2EthCfmMepAttrControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 6 }
sle2EthCfmMepAttrControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 7 }
sle2EthCfmMepAttrControlMaVid OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 8 }
sle2EthCfmMepAttrControlMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 9 }
sle2EthCfmMepAttrControlActive OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 10 }
sle2EthCfmMepAttrControlCcmLtmPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 11 }
sle2EthCfmMepAttrContrlLowPrDef OBJECT-TYPE
SYNTAX INTEGER
{
allDef(1),
macRemErrXcon(2),
remErrXcon(3),
errXcon(4),
xcon(5),
noXcon(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 12 }
sle2EthCfmMepAttrContrlFngAlarmTime OBJECT-TYPE
SYNTAX Integer32 (250..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 13 }
sle2EthCfmMepAttrControlResetFngTime OBJECT-TYPE
SYNTAX Integer32 (250..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 14 }
sle2EthCfmMepAttrControlCcmLtmFlag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 15 }
sle2EthCfmMepAttrControlTxLtmTargetMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 16 }
sle2EthCfmMepAttrControlTxLtmTargetMepId OBJECT-TYPE
SYNTAX Integer32 (0..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 17 }
sle2EthCfmMepAttrControlTxLtmTargetIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 18 }
sle2EthCfmMepAttrControlTxLtmTtl OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 19 }
sle2EthCfmMepAttrControlTxLtmEgressId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 20 }
sle2EthCfmMepAttrControlTxLbmStatus OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 21 }
sle2EthCfmMepAttrControlTxLbmDestMacAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 22 }
sle2EthCfmMepAttrControlTxLbmDestMepId OBJECT-TYPE
SYNTAX Integer32 (0..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 23 }
sle2EthCfmMepAttrControlTxLbmDestIsMepId OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 24 }
sle2EthCfmMepAttrControlTxLbmMessages OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 25 }
sle2EthCfmMepAttrControlTxLbmDataTlv OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 26 }
sle2EthCfmMepAttrControlTxLbmVlanPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 27 }
sle2EthCfmMepAttrControlTxLbmVlanDropEnable OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 28 }
sle2EthCfmMepAttrControlTxLbmTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 29 }
sle2EthCfmMepAttrControlLbrTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrControl 30 }
sle2EthCfmMepAttrNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmMepAttributs 3 }
sle2EthCfmMepFaultProfileChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrCcmLtmPriority, sle2EthCfmMepAttrLowPrDef, sle2EthCfmMepAttrFngAlarmTime,
sle2EthCfmMepAttrResetFngTime, sle2EthCfmMepAttrActive }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrNotification 1 }
sle2EthCfmMepTxLtmProfileChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrCcmLtmFlag, sle2EthCfmMepAttrTxLtmTargetMac, sle2EthCfmMepAttrTxLtmTargetMepId,
sle2EthCfmMepAttrTxLtmTargetIsMepId, sle2EthCfmMepAttrTxLtmTtl, sle2EthCfmMepAttrTxLtmEgressId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrNotification 2 }
sle2EthCfmMepTxLbmProfileChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmMepAttrTxLbmStatus, sle2EthCfmMepAttrTxLbmDestMac, sle2EthCfmMepAttrTxLbmDestMepId,
sle2EthCfmMepAttrTxLbmDestIsMepId, sle2EthCfmMepAttrTxLbmMessages, sle2EthCfmMepAttrTxLbmDataTlv, sle2EthCfmMepAttrTxLbmVlanPriority, sle2EthCfmMepAttrTxLbmVlanDropEnable,
sle2EthCfmMepAttrTxLbmTimeOut, sle2EthCfmMepAttrLbrTimeOut }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrNotification 3 }
sle2EthCfmMepAuttributesAllCleared NOTIFICATION-TYPE
OBJECTS { sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMepAttrNotification 4 }
sle2EthernetCfmXcheck OBJECT IDENTIFIER ::= { sle2EthernetCfm 8 }
sle2EthCfmXcheckTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmXcheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmXcheck 1 }
sle2EthCfmXcheckEntry OBJECT-TYPE
SYNTAX Sle2EthCfmXcheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmXcheckRmepId }
::= { sle2EthCfmXcheckTable 1 }
Sle2EthCfmXcheckEntry ::=
SEQUENCE {
sle2EthCfmXcheckRmepId
Integer32,
sle2EthCfmXcheckRmepMac
OCTET STRING
}
sle2EthCfmXcheckRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckEntry 1 }
sle2EthCfmXcheckRmepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckEntry 2 }
sle2EthCfmXcheckControl OBJECT IDENTIFIER ::= { sle2EthernetCfmXcheck 2 }
sle2EthCfmXcheckControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createCfmXcheckMep(1),
destoryCfmXcheckMep(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 1 }
sle2EthCfmXcheckControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 2 }
sle2EthCfmXcheckControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 3 }
sle2EthCfmXcheckControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 4 }
sle2EthCfmXcheckControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 5 }
sle2EthCfmXcheckControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 6 }
sle2EthCfmXcheckControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 7 }
sle2EthCfmXcheckControlMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 8 }
sle2EthCfmXcheckControlRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 9 }
sle2EthCfmXcheckControlRmepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckControl 10 }
sle2EthCfmXcheckNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmXcheck 3 }
sle2EthCfmXcheckMepCreated NOTIFICATION-TYPE
OBJECTS { sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlReqResult, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmXcheckRmepId, sle2EthCfmXcheckRmepMac }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckNotification 1 }
sle2EthCfmXcheckMepDestoryed NOTIFICATION-TYPE
OBJECTS { sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlReqResult, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmXcheckControlBridgeId, sle2EthCfmXcheckControlMdName,
sle2EthCfmXcheckControlMaVid, sle2EthCfmXcheckControlRmepId, sle2EthCfmXcheckControlRmepMac }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmXcheckNotification 2 }
sle2EthernetCfmLoopback OBJECT IDENTIFIER ::= { sle2EthernetCfm 9 }
sle2EthCfmLoopbackTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmLoopback 1 }
sle2EthCfmLoopbackEntry OBJECT-TYPE
SYNTAX Sle2EthCfmLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
::= { sle2EthCfmLoopbackTable 1 }
Sle2EthCfmLoopbackEntry ::=
SEQUENCE {
sle2EthCfmLbFrameType
INTEGER,
sle2EthCfmLbReceivedCount
Integer32,
sle2EthCfmLbTxMessages
Integer32,
sle2EthCfmLbResponseCount
Integer32,
sle2EthCfmLbRemoteMacAddress
OCTET STRING
}
sle2EthCfmLbFrameType OBJECT-TYPE
SYNTAX INTEGER
{
unicast(1),
multicast(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackEntry 1 }
sle2EthCfmLbReceivedCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackEntry 2 }
sle2EthCfmLbTxMessages OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackEntry 3 }
sle2EthCfmLbResponseCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackEntry 4 }
sle2EthCfmLbRemoteMacAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackEntry 5 }
sle2EthCfmLoopbackControl OBJECT IDENTIFIER ::= { sle2EthernetCfmLoopback 2 }
sle2EthCfmLbControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
transmitMulticastLb(1),
transmitUnicastLb(2),
transmitMacLb(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 1 }
sle2EthCfmLbControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 2 }
sle2EthCfmLbControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 3 }
sle2EthCfmLbControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 4 }
sle2EthCfmLbControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 5 }
sle2EthCfmLbControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 6 }
sle2EthCfmLbControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 7 }
sle2EthCfmLbControlMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 8 }
sle2EthCfmLbControlMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 9 }
sle2EthCfmLbControlMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 10 }
sle2EthCfmLbControlRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 11 }
sle2EthCfmLbControlRmepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 12 }
sle2EthCfmLbControlTlvType OBJECT-TYPE
SYNTAX INTEGER
{
tlvData(1),
tlvTest(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 13 }
sle2EthCfmLbControlTlvData OBJECT-TYPE
SYNTAX Integer32 (1..9000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 14 }
sle2EthCfmLbControlTlvTest OBJECT-TYPE
SYNTAX INTEGER
{
pattern1(1),
pattern2(2),
pattern3(3),
pattern4(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 15 }
sle2EthCfmLbControlRecursive OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackControl 16 }
sle2EthCfmLoopbackNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmLoopback 3 }
sle2EthCfmLbTransmitMulticastFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName,
sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlTlvType, sle2EthCfmLbControlTlvData,
sle2EthCfmLbControlTlvTest, sle2EthCfmLbControlRecursive }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackNotification 1 }
sle2EthCfmLbTransmitUnicastFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName,
sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepId, sle2EthCfmLbControlTlvType,
sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackNotification 2 }
sle2EthCfmLbTransmitMacFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlBridgeId, sle2EthCfmLbControlMdName,
sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepMac, sle2EthCfmLbControlTlvType,
sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackNotification 3 }
sle2EthCfmLbrFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmLbControlRequest, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmLbFrameType, sle2EthCfmLbReceivedCount, sle2EthCfmLbRemoteMacAddress,
sle2EthCfmLbTxMessages, sle2EthCfmLbResponseCount }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLoopbackNotification 4 }
sle2EthernetCfmLinkTrace OBJECT IDENTIFIER ::= { sle2EthernetCfm 10 }
sle2EthCfmLinkTraceTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmLinkTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmLinkTrace 1 }
sle2EthCfmLinkTraceEntry OBJECT-TYPE
SYNTAX Sle2EthCfmLinkTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
::= { sle2EthCfmLinkTraceTable 1 }
Sle2EthCfmLinkTraceEntry ::=
SEQUENCE {
sle2EthCfmLtrMepMac
OCTET STRING,
sle2EthCfmLtrHops
Integer32,
sle2EthCfmLtrRelay
INTEGER,
sle2EthCfmLtrIngressEgress
INTEGER,
sle2EthCfmLtrIngress
INTEGER,
sle2EthCfmLtrEgress
INTEGER
}
sle2EthCfmLtrMepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceEntry 1 }
sle2EthCfmLtrHops OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceEntry 2 }
sle2EthCfmLtrRelay OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
rlyHit(1),
rlyFDB(2),
rlyMPDB(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceEntry 3 }
sle2EthCfmLtrIngressEgress OBJECT-TYPE
SYNTAX INTEGER
{
ingress(1),
egress(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceEntry 4 }
sle2EthCfmLtrIngress OBJECT-TYPE
SYNTAX INTEGER
{
ingNoTlv(0),
ingOK(1),
ingDown(2),
ingBlocked(3),
ingVid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceEntry 5 }
sle2EthCfmLtrEgress OBJECT-TYPE
SYNTAX INTEGER
{
egrNoTlv(0),
egrOK(1),
egrDown(2),
egrBlocked(3),
egrVid(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceEntry 6 }
sle2EthCfmLinkTraceControl OBJECT IDENTIFIER ::= { sle2EthernetCfmLinkTrace 2 }
sle2EthCfmLtControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
transmitLtDomain(1),
transmitLtLevel(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 1 }
sle2EthCfmLtControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 2 }
sle2EthCfmLtControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 3 }
sle2EthCfmLtControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 4 }
sle2EthCfmLtControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 5 }
sle2EthCfmLtControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 6 }
sle2EthCfmLtControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 7 }
sle2EthCfmLtControlMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 8 }
sle2EthCfmLtControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 9 }
sle2EthCfmLtControlRmepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceControl 10 }
sle2EthCfmLtControlMepId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"indicates mepid of local."
::= { sle2EthCfmLinkTraceControl 11 }
sle2EthCfmLinkTraceNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmLinkTrace 3 }
sle2EthCfmLtTransmitDomainFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMdName,
sle2EthCfmLtControlMaVid, sle2EthCfmLtControlRmepMac }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceNotification 1 }
sle2EthCfmLtTransmitLevelFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMaVid,
sle2EthCfmLtControlLevel, sle2EthCfmLtControlRmepMac }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceNotification 2 }
sle2EthCfmLtrFinished NOTIFICATION-TYPE
OBJECTS { sle2EthCfmLtControlRequest, sle2EthCfmLtControlReqResult, sle2EthCfmLtControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName,
sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmLtrMepMac, sle2EthCfmLtrHops, sle2EthCfmLtrRelay,
sle2EthCfmLtrIngressEgress, sle2EthCfmLtrIngress, sle2EthCfmLtrEgress }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLinkTraceNotification 3 }
sle2EthernetCfmAis OBJECT IDENTIFIER ::= { sle2EthernetCfm 11 }
sle2EthernetCfmAisInfo OBJECT IDENTIFIER ::= { sle2EthernetCfmAis 1 }
sle2EthCfmAisInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmAisInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmAisInfo 1 }
sle2EthCfmAisInfoEntry OBJECT-TYPE
SYNTAX Sle2EthCfmAisInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoDefectConditions,
sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoRmepMac }
::= { sle2EthCfmAisInfoTable 1 }
Sle2EthCfmAisInfoEntry ::=
SEQUENCE {
sle2EthCfmAisInfoStatus
INTEGER,
sle2EthCfmAisInfoDefectConditions
INTEGER,
sle2EthCfmAisInfoLevel
Integer32,
sle2EthCfmAisInfoFrameType
INTEGER,
sle2EthCfmAisInfoRmepMac
OCTET STRING,
sle2EthCfmAisInfoInterval
Integer32,
sle2EthCfmAisInfoReceivedDefectConditions
INTEGER,
sle2EthCfmAisInfoLastReceivedDefectCondition
INTEGER
}
sle2EthCfmAisInfoStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 1 }
sle2EthCfmAisInfoDefectConditions OBJECT-TYPE
SYNTAX INTEGER
{
all(1),
loc(2),
mismerge(3),
unexpectedMep(4),
unexpectedMegLevel(5),
unexpectedPeriod(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 2 }
sle2EthCfmAisInfoLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 3 }
sle2EthCfmAisInfoFrameType OBJECT-TYPE
SYNTAX INTEGER
{
unicast(1),
multicast(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 4 }
sle2EthCfmAisInfoRmepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 5 }
sle2EthCfmAisInfoInterval OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 6 }
sle2EthCfmAisInfoReceivedDefectConditions OBJECT-TYPE
SYNTAX INTEGER
{
all(1),
loc(2),
mismerge(3),
unexpectedMep(4),
unexpectedMegLevel(5),
unexpectedPeriod(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 7 }
sle2EthCfmAisInfoLastReceivedDefectCondition OBJECT-TYPE
SYNTAX INTEGER
{
all(1),
loc(2),
mismerge(3),
unexpectedMep(4),
unexpectedMegLevel(5),
unexpectedPeriod(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoEntry 8 }
sle2EthCfmAisInfoControl OBJECT IDENTIFIER ::= { sle2EthernetCfmAisInfo 2 }
sle2EthCfmAisInfoControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
setCfmAisInfoStatus(1),
setCfmAisInfoInterval(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 1 }
sle2EthCfmAisInfoControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 2 }
sle2EthCfmAisInfoControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 3 }
sle2EthCfmAisInfoControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 4 }
sle2EthCfmAisInfoControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 5 }
sle2EthCfmAisInfoControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 6 }
sle2EthCfmAisInfoControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 7 }
sle2EthCfmAisInfoControlMaVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 8 }
sle2EthCfmAisInfoControlMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 9 }
sle2EthCfmAisInfoControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 10 }
sle2EthCfmAisInfoControlDefectConditions OBJECT-TYPE
SYNTAX INTEGER
{
all(1),
loc(2),
mismerge(3),
unexpectedMep(4),
unexpectedMegLevel(5),
unexpectedPeriod(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 11 }
sle2EthCfmAisInfoControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 12 }
sle2EthCfmAisInfoControlFrameType OBJECT-TYPE
SYNTAX INTEGER
{
unicast(1),
multicast(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 13 }
sle2EthCfmAisInfoControlRmepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 14 }
sle2EthCfmAisInfoControlInterval OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoControl 15 }
sle2EthCfmAisInfoNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmAisInfo 3 }
sle2EthCfmAisInfoStatusChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoStatus,
sle2EthCfmAisInfoDefectConditions, sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoFrameType, sle2EthCfmAisInfoRmepMac }
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoNotification 1 }
sle2EthCfmAisInfoIntervalChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId, sle2EthCfmAisInfoInterval
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmAisInfoNotification 2 }
sle2EthernetCfmSrvAis OBJECT IDENTIFIER ::= { sle2EthernetCfmAis 2 }
sle2EthCfmSrvAisTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmSrvAisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmSrvAis 1 }
sle2EthCfmSrvAisEntry OBJECT-TYPE
SYNTAX Sle2EthCfmSrvAisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmSrvAisIfIndex }
::= { sle2EthCfmSrvAisTable 1 }
Sle2EthCfmSrvAisEntry ::=
SEQUENCE {
sle2EthCfmSrvAisIfIndex
Integer32,
sle2EthCfmSrvAisEnable
INTEGER,
sle2EthCfmSrvAislevel
Integer32,
sle2EthCfmSrvAisInterval
Integer32
}
sle2EthCfmSrvAisIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisEntry 1 }
sle2EthCfmSrvAisEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisEntry 2 }
sle2EthCfmSrvAislevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisEntry 3 }
sle2EthCfmSrvAisInterval OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisEntry 4 }
sle2EthCfmSrvAisControl OBJECT IDENTIFIER ::= { sle2EthernetCfmSrvAis 2 }
sle2EthCfmSrvAisControlRequest OBJECT-TYPE
SYNTAX INTEGER { setCfmSrvAisEnable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 1 }
sle2EthCfmSrvAisControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 2 }
sle2EthCfmSrvAisControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 3 }
sle2EthCfmSrvAisControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 4 }
sle2EthCfmSrvAisControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 5 }
sle2EthCfmSrvAisControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 6 }
sle2EthCfmSrvAisControlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 7 }
sle2EthCfmSrvAisControlEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 8 }
sle2EthCfmSrvAisControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 9 }
sle2EthCfmSrvAisControlInterval OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisControl 10 }
sle2EthCfmSrvAisNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmSrvAis 3 }
sle2EthCfmSrvAisChanged NOTIFICATION-TYPE
OBJECTS { sle2EthCfmBridgeId, sle2EthCfmSrvAisIfIndex, sle2EthCfmSrvAisEnable, sle2EthCfmSrvAislevel, sle2EthCfmSrvAisInterval
}
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmSrvAisNotification 1 }
sle2EthernetCfmLmStatus OBJECT IDENTIFIER ::= { sle2EthernetCfm 12 }
sle2EthCfmLmmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmLmmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmLmStatus 1 }
sle2EthCfmLmmStatusEntry OBJECT-TYPE
SYNTAX Sle2EthCfmLmmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
::= { sle2EthCfmLmmStatusTable 1 }
Sle2EthCfmLmmStatusEntry ::=
SEQUENCE {
sle2EthCfmLmmStatusRmepId
Integer32,
sle2EthCfmLmmStatusStartTime
TimeTicks,
sle2EthCfmLmmStatusCurrentTime
TimeTicks,
sle2EthCfmLmmStatusEndTime
TimeTicks,
sle2EthCfmLmmStatusNeerLoss
Integer32,
sle2EthCfmLmmStatusFarLoss
Integer32,
sle2EthCfmLmmStatusCurNeerLoss
Integer32,
sle2EthCfmLmmStatusCurFarLoss
Integer32
}
sle2EthCfmLmmStatusRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 1 }
sle2EthCfmLmmStatusStartTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 2 }
sle2EthCfmLmmStatusCurrentTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 3 }
sle2EthCfmLmmStatusEndTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 4 }
sle2EthCfmLmmStatusNeerLoss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 5 }
sle2EthCfmLmmStatusFarLoss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 6 }
sle2EthCfmLmmStatusCurNeerLoss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 7 }
sle2EthCfmLmmStatusCurFarLoss OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmLmmStatusEntry 8 }
sle2EthernetCfmRmep OBJECT IDENTIFIER ::= { sle2EthernetCfm 13 }
sle2EthCfmRmepTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmRmepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmRmep 1 }
sle2EthCfmRmepEntry OBJECT-TYPE
SYNTAX Sle2EthCfmRmepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmRmepId }
::= { sle2EthCfmRmepTable 1 }
Sle2EthCfmRmepEntry ::=
SEQUENCE {
sle2EthCfmRmepId
Integer32,
sle2EthCfmRempMepId
Integer32,
sle2EthCfmRmepLevel
Integer32,
sle2EthCfmRmepMaVid
Integer32,
sle2EthCfmRmepActiveState
INTEGER,
sle2EthCfmRmepRemoteMac
OCTET STRING,
sle2EthCfmRmepRdi
INTEGER,
sle2EthCfmRmepFlags
INTEGER
}
sle2EthCfmRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates mepid of remote."
::= { sle2EthCfmRmepEntry 1 }
sle2EthCfmRempMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmRmepEntry 2 }
sle2EthCfmRmepLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maintenance domain level."
::= { sle2EthCfmRmepEntry 3 }
sle2EthCfmRmepMaVid OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN Identifier.
0: default Ma vid
"
::= { sle2EthCfmRmepEntry 4 }
sle2EthCfmRmepActiveState OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates active status."
::= { sle2EthCfmRmepEntry 5 }
sle2EthCfmRmepRemoteMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the remote mac address."
::= { sle2EthCfmRmepEntry 6 }
sle2EthCfmRmepRdi OBJECT-TYPE
SYNTAX INTEGER
{
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the RDI flags."
::= { sle2EthCfmRmepEntry 7 }
sle2EthCfmRmepFlags OBJECT-TYPE
SYNTAX INTEGER
{
configured(1),
configuredLearnt(2),
learnt(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates configure status"
::= { sle2EthCfmRmepEntry 8 }
sle2EthCfmRmepControl OBJECT IDENTIFIER ::= { sle2EthernetCfmRmep 2 }
sle2EthCfmRmepControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
clearRmepDomain(1),
clearRmepLevel(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sle2EthCfmRmepControl 1 }
sle2EthCfmRmepControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of user command"
::= { sle2EthCfmRmepControl 2 }
sle2EthCfmRmepControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sle2EthCfmRmepControl 3 }
sle2EthCfmRmepControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sle2EthCfmRmepControl 4 }
sle2EthCfmRmepControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Result of the last command."
::= { sle2EthCfmRmepControl 5 }
sle2EthCfmRmepControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates bridgegroup id
1: default bridge id
"
::= { sle2EthCfmRmepControl 6 }
sle2EthCfmRmepControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maintenance domain name."
::= { sle2EthCfmRmepControl 7 }
sle2EthCfmRmepControlMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the maintenance domain level."
::= { sle2EthCfmRmepControl 8 }
sle2EthCfmRmepNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmRmep 3 }
sle2EthCfmRmepDomainCleared NOTIFICATION-TYPE
OBJECTS { sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdName
}
STATUS current
DESCRIPTION
"clearRmepDomain"
::= { sle2EthCfmRmepNotification 1 }
sle2EthCfmRmepLevelCleared NOTIFICATION-TYPE
OBJECTS { sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdLevel
}
STATUS current
DESCRIPTION
"clearRmepLevel"
::= { sle2EthCfmRmepNotification 2 }
sle2EthernetCfmMip OBJECT IDENTIFIER ::= { sle2EthernetCfm 14 }
sle2EthCfmMipTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmMip 1 }
sle2EthCfmMipEntry OBJECT-TYPE
SYNTAX Sle2EthCfmMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMipVid, sle2EthCfmMipMdLevel, sle2EthCfmMipIfindex }
::= { sle2EthCfmMipTable 1 }
Sle2EthCfmMipEntry ::=
SEQUENCE {
sle2EthCfmMipVid
Integer32,
sle2EthCfmMipMdLevel
Integer32,
sle2EthCfmMipIfindex
Integer32,
sle2EthCfmMipLocalMac
OCTET STRING
}
sle2EthCfmMipVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2EthCfmMipEntry 1 }
sle2EthCfmMipMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maintenance domain level."
::= { sle2EthCfmMipEntry 2 }
sle2EthCfmMipIfindex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indcates the port interface index."
::= { sle2EthCfmMipEntry 3 }
sle2EthCfmMipLocalMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mac address of local mep."
::= { sle2EthCfmMipEntry 4 }
sle2EthernetCfmStatistics OBJECT IDENTIFIER ::= { sle2EthernetCfm 15 }
sle2EthCfmStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmStatistics 1 }
sle2EthCfmStatisticsEntry OBJECT-TYPE
SYNTAX Sle2EthCfmStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmMaVid, sle2EthCfmMepInfoId }
::= { sle2EthCfmStatisticsTable 1 }
Sle2EthCfmStatisticsEntry ::=
SEQUENCE {
sle2EthCfmStatCcmSent
Gauge32,
sle2EthCfmStatCcmRevOutOfSeq
Gauge32,
sle2EthCfmStatLbrSent
Gauge32,
sle2EthCfmStatLbrRevValid
Gauge32,
sle2EthCfmStatLbrRevBadMsdu
Gauge32,
sle2EthCfmStatLbrRevOutOfSeq
Gauge32,
sle2EthCfmStatLtrRevUnexpected
Counter32
}
sle2EthCfmStatCcmSent OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the ccm packet number."
::= { sle2EthCfmStatisticsEntry 1 }
sle2EthCfmStatCcmRevOutOfSeq OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the received out of sequence number."
::= { sle2EthCfmStatisticsEntry 2 }
sle2EthCfmStatLbrSent OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the lbr packet number."
::= { sle2EthCfmStatisticsEntry 3 }
sle2EthCfmStatLbrRevValid OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the valid lbr packet number."
::= { sle2EthCfmStatisticsEntry 4 }
sle2EthCfmStatLbrRevBadMsdu OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the bad lbr packet number."
::= { sle2EthCfmStatisticsEntry 5 }
sle2EthCfmStatLbrRevOutOfSeq OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the received out of sequence number."
::= { sle2EthCfmStatisticsEntry 6 }
sle2EthCfmStatLtrRevUnexpected OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the unexected received lbr packet number."
::= { sle2EthCfmStatisticsEntry 7 }
sle2EthernetCfmActiveLevel OBJECT IDENTIFIER ::= { sle2EthernetCfm 16 }
sle2EthCfmActiveLevelTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmActiveLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmActiveLevel 1 }
sle2EthCfmActiveLevelEntry OBJECT-TYPE
SYNTAX Sle2EthCfmActiveLevelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMaVid, sle2EthCfmAcitveLevelIfIndex }
::= { sle2EthCfmActiveLevelTable 1 }
Sle2EthCfmActiveLevelEntry ::=
SEQUENCE {
sle2EthCfmAcitveLevelIfIndex
Integer32,
sle2EthCfmActiveLevelStatus
BITS
}
sle2EthCfmAcitveLevelIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interface index."
::= { sle2EthCfmActiveLevelEntry 1 }
sle2EthCfmActiveLevelStatus OBJECT-TYPE
SYNTAX BITS
{
level7(0),
level6(1),
level5(2),
level4(3),
level3(4),
level2(5),
level1(6),
level0(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates status of active level
"
::= { sle2EthCfmActiveLevelEntry 2 }
sle2EthernetCfmError OBJECT IDENTIFIER ::= { sle2EthernetCfm 17 }
sle2EthCfmErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmError 1 }
sle2EthCfmErrorEntry OBJECT-TYPE
SYNTAX Sle2EthCfmErrorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmMdName, sle2EthCfmErrorIndex }
::= { sle2EthCfmErrorTable 1 }
Sle2EthCfmErrorEntry ::=
SEQUENCE {
sle2EthCfmErrorIndex
Integer32,
sle2EthCfmErrorMdLevel
Integer32,
sle2EthCfmErrorMaVid
Integer32,
sle2EthCfmErrorMepId
Integer32,
sle2EthCfmErrorRmepMac
OCTET STRING,
sle2EthCfmErrorReason
INTEGER,
sle2EthCfmErrorServiceId
OCTET STRING
}
sle2EthCfmErrorIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the error index."
::= { sle2EthCfmErrorEntry 1 }
sle2EthCfmErrorMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of MD."
::= { sle2EthCfmErrorEntry 2 }
sle2EthCfmErrorMaVid OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VLAN Identifier.
0: default Ma vid
"
::= { sle2EthCfmErrorEntry 3 }
sle2EthCfmErrorMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MA end point ID."
::= { sle2EthCfmErrorEntry 4 }
sle2EthCfmErrorRmepMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates mac address of remote mep "
::= { sle2EthCfmErrorEntry 5 }
sle2EthCfmErrorReason OBJECT-TYPE
SYNTAX INTEGER
{
rmepDown(0),
confError(1),
fowardLoop(2),
crossConnect(3),
missingRmep(4),
unknownMep(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates error reason."
::= { sle2EthCfmErrorEntry 6 }
sle2EthCfmErrorServiceId OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maintenance association name."
::= { sle2EthCfmErrorEntry 7 }
sle2EthCfmErrorControl OBJECT IDENTIFIER ::= { sle2EthernetCfmError 2 }
sle2EthCfmErrorControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
clearCfmErrorDomain(1),
clearCfmErrorLevel(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sle2EthCfmErrorControl 1 }
sle2EthCfmErrorControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of user command"
::= { sle2EthCfmErrorControl 2 }
sle2EthCfmErrorControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sle2EthCfmErrorControl 3 }
sle2EthCfmErrorControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sle2EthCfmErrorControl 4 }
sle2EthCfmErrorControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Result of the last command."
::= { sle2EthCfmErrorControl 5 }
sle2EthCfmErrorControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates bridgegroup id
1: default bridge id
"
::= { sle2EthCfmErrorControl 6 }
sle2EthCfmErrorControlMdName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maintenance domain name."
::= { sle2EthCfmErrorControl 7 }
sle2EthCfmErrorControlMdLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates level of MD."
::= { sle2EthCfmErrorControl 8 }
sle2EthCfmErrorNotification OBJECT IDENTIFIER ::= { sle2EthernetCfmError 3 }
sle2EthCfmErrorDomainCleared NOTIFICATION-TYPE
OBJECTS { sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmMdName
}
STATUS current
DESCRIPTION
"clearCfmErrorDomain"
::= { sle2EthCfmErrorNotification 1 }
sle2EthCfmErrorLevelCleared NOTIFICATION-TYPE
OBJECTS { sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlTimeStamp, sle2EthCfmBridgeId, sle2EthCfmErrorMdLevel
}
STATUS current
DESCRIPTION
"clearCfmErrorLevel"
::= { sle2EthCfmErrorNotification 2 }
sle2EthernetCfmLtCache OBJECT IDENTIFIER ::= { sle2EthernetCfm 18 }
sle2EthCfmLtCacheTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2EthCfmLtCacheEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2EthernetCfmLtCache 1 }
sle2EthCfmLtCacheEntry OBJECT-TYPE
SYNTAX Sle2EthCfmLtCacheEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2EthCfmBridgeId, sle2EthCfmLtCacheIndex }
::= { sle2EthCfmLtCacheTable 1 }
Sle2EthCfmLtCacheEntry ::=
SEQUENCE {
sle2EthCfmLtCacheIndex
Integer32,
sle2EthCfmLtCacheSrcMac
OCTET STRING,
sle2EthCfmLtCacheHops
Integer32,
sle2EthCfmLtCacheRelay
INTEGER
}
sle2EthCfmLtCacheIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the linktrace cache index."
::= { sle2EthCfmLtCacheEntry 1 }
sle2EthCfmLtCacheSrcMac OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates MAC address.
(SIZE (6))"
::= { sle2EthCfmLtCacheEntry 2 }
sle2EthCfmLtCacheHops OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates TTL field value for a returned LTR."
::= { sle2EthCfmLtCacheEntry 3 }
sle2EthCfmLtCacheRelay OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
rlyHit(1),
rlyFDB(2),
rlyMPDB(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value returned in the Relay Action field"
::= { sle2EthCfmLtCacheEntry 4 }
sle2Erps OBJECT IDENTIFIER ::= { sleFaultMgmt 18 }
sle2ErpsPhyRing OBJECT IDENTIFIER ::= { sle2Erps 1 }
sle2ErpsPhyRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2ErpsPhyRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsPhyRing 1 }
sle2ErpsPhyRingEntry OBJECT-TYPE
SYNTAX Sle2ErpsPhyRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName }
::= { sle2ErpsPhyRingTable 1 }
Sle2ErpsPhyRingEntry ::=
SEQUENCE {
sle2ErpsPhyRingBridgeId
Integer32,
sle2ErpsPhyRingName
OCTET STRING,
sle2ErpsPhyRingEastPort
Integer32,
sle2ErpsPhyRingEastMepId
Integer32,
sle2ErpsPhyRingEastRmepId
Integer32,
sle2ErpsPhyRingWestPort
Integer32,
sle2ErpsPhyRingWestMepId
Integer32,
sle2ErpsPhyRingWestRmepId
Integer32
}
sle2ErpsPhyRingBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates primary bridgegroup id
1: default bridge id
100: backbone"
::= { sle2ErpsPhyRingEntry 1 }
sle2ErpsPhyRingName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical ring name (maximum 37 characters)."
::= { sle2ErpsPhyRingEntry 2 }
sle2ErpsPhyRingEastPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s east port(ifindex)"
::= { sle2ErpsPhyRingEntry 3 }
sle2ErpsPhyRingEastMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsPhyRingEntry 4 }
sle2ErpsPhyRingEastRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsPhyRingEntry 5 }
sle2ErpsPhyRingWestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s west port(ifindex)"
::= { sle2ErpsPhyRingEntry 6 }
sle2ErpsPhyRingWestMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsPhyRingEntry 7 }
sle2ErpsPhyRingWestRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsPhyRingEntry 8 }
sle2ErpsPhyRingControl OBJECT IDENTIFIER ::= { sle2ErpsPhyRing 2 }
sle2ErpsPhyRingControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createPhyRing(1),
destoryPhyRing(2),
addEastPort(3),
delEastPort(4),
addWestPort(5),
delWestPort(6),
addEastPortMepId(7),
delEastPortMepId(8),
addWestPortMepId(9),
delWestPortMepId(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sle2ErpsPhyRingControl 1 }
sle2ErpsPhyRingControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of user command"
::= { sle2ErpsPhyRingControl 2 }
sle2ErpsPhyRingControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sle2ErpsPhyRingControl 3 }
sle2ErpsPhyRingControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sle2ErpsPhyRingControl 4 }
sle2ErpsPhyRingControlReqResult OBJECT-TYPE
SYNTAX SleControlRequestResultType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Result of the last command."
::= { sle2ErpsPhyRingControl 5 }
sle2ErpsPhyRingControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates primary bridgegroup id
1: default bridge id
100: backbone
"
::= { sle2ErpsPhyRingControl 6 }
sle2ErpsPhyRingControName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical ring name (maximum 37 characters)."
::= { sle2ErpsPhyRingControl 7 }
sle2ErpsPhyRingControEastPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s east interface index"
::= { sle2ErpsPhyRingControl 8 }
sle2ErpsPhyRingControWestPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s west interface index"
::= { sle2ErpsPhyRingControl 9 }
sle2ErpsPhyRingControlMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsPhyRingControl 10 }
sle2ErpsPhyRingControlRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsPhyRingControl 11 }
sleErpsPhyRingNotification OBJECT IDENTIFIER ::= { sle2ErpsPhyRing 3 }
sle2ErpsPhyRingCreated NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName
}
STATUS current
DESCRIPTION
"createPhyRing"
::= { sleErpsPhyRingNotification 1 }
sle2ErpsPhyRingDestoryed NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
}
STATUS current
DESCRIPTION
"destoryPhyRing"
::= { sleErpsPhyRingNotification 2 }
sle2ErpsPhyRingEastPortAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
sle2ErpsPhyRingEastPort }
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 3 }
sle2ErpsPhyRingEastPortDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
}
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 4 }
sle2ErpsPhyRingWestPortAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
sle2ErpsPhyRingWestPort }
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 5 }
sle2ErpsPhyRingWestPortDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
}
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 6 }
sle2ErpsPhyRingEastMepIdAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
sle2ErpsPhyRingEastMepId, sle2ErpsPhyRingEastRmepId }
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 7 }
sle2ErpsPhyRingEastMepIdDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
}
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 8 }
sle2ErpsPhyRingWestMepIdAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
sle2ErpsPhyRingWestMepId, sle2ErpsPhyRingWestRmepId }
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 9 }
sle2ErpsPhyRingWestMepIdDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName
}
STATUS current
DESCRIPTION
"Description."
::= { sleErpsPhyRingNotification 10 }
sle2ErpsProfile OBJECT IDENTIFIER ::= { sle2Erps 2 }
sle2ErpsProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2ErpsProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsProfile 1 }
sle2ErpsProfileEntry OBJECT-TYPE
SYNTAX Sle2ErpsProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2ErpsProfileBridgeId, sle2ErpsProfileName }
::= { sle2ErpsProfileTable 1 }
Sle2ErpsProfileEntry ::=
SEQUENCE {
sle2ErpsProfileBridgeId
Integer32,
sle2ErpsProfileName
OCTET STRING,
sle2ErpsProfileHoldOffTime
INTEGER,
sle2ErpsProfileGuardTime
INTEGER,
sle2ErpsProfileWaitToRestore
INTEGER,
sle2ErpsProfileNonRevertive
INTEGER
}
sle2ErpsProfileBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates primary bridgegroup id
1: default bridge id
100: backbone
"
::= { sle2ErpsProfileEntry 1 }
sle2ErpsProfileName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Profile name (maximum 32 characters)."
::= { sle2ErpsProfileEntry 2 }
sle2ErpsProfileHoldOffTime OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the hold-off time
default : 0
"
DEFVAL { 0 }
::= { sle2ErpsProfileEntry 3 }
sle2ErpsProfileGuardTime OBJECT-TYPE
SYNTAX INTEGER (10..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the guard time
default : 500
"
DEFVAL { 500 }
::= { sle2ErpsProfileEntry 4 }
sle2ErpsProfileWaitToRestore OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time
default : 5
"
DEFVAL { 5 }
::= { sle2ErpsProfileEntry 5 }
sle2ErpsProfileNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
revertive(0),
nonRevertive(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Non-Revertive or Revertive."
::= { sle2ErpsProfileEntry 6 }
sle2ErpsProfileControl OBJECT IDENTIFIER ::= { sle2ErpsProfile 2 }
sle2ErpsProfileControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createErpsProfile(1),
destroyErpsProfile(2),
setProfileTimer(3),
setNoneRevertive(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The request of a user command"
::= { sle2ErpsProfileControl 1 }
sle2ErpsProfileControlStatus OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of user command"
::= { sle2ErpsProfileControl 2 }
sle2ErpsProfileControlTimer OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time for the manager for a long running user command"
::= { sle2ErpsProfileControl 3 }
sle2ErpsProfileControlTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time stamp of the last command(end of command)"
::= { sle2ErpsProfileControl 4 }
sle2ErpsProfileControlReqResult OBJECT-TYPE
SYNTAX SleControlStatusType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Result of the last command."
::= { sle2ErpsProfileControl 5 }
sle2ErpsProfileControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates primary bridgegroup id
1: default bridge id
100: backbone
"
::= { sle2ErpsProfileControl 6 }
sle2ErpsProfileControlName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile name (maximum 32 characters)."
::= { sle2ErpsProfileControl 7 }
sle2ErpsProfileControlHoldOffTime OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the hold-off time
default : 0
"
DEFVAL { 0 }
::= { sle2ErpsProfileControl 8 }
sle2ErpsProfileControlGuardTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the guard time
default : 500
"
DEFVAL { 500 }
::= { sle2ErpsProfileControl 9 }
sle2ErpsProfileControlWaitToRestore OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the wait-to-restore time
default : 5
"
DEFVAL { 5 }
::= { sle2ErpsProfileControl 10 }
sle2ErpsProfileControlNonRevertive OBJECT-TYPE
SYNTAX INTEGER
{
revertive(0),
nonRevertive(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Non-Revertive or Revertive."
::= { sle2ErpsProfileControl 11 }
sle2ErpsProfileNotification OBJECT IDENTIFIER ::= { sle2ErpsProfile 3 }
sle2ErpsProfileCreated NOTIFICATION-TYPE
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName
}
STATUS current
DESCRIPTION
"createErpsProfile"
::= { sle2ErpsProfileNotification 1 }
sle2ErpsProfileDestoryed NOTIFICATION-TYPE
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileControlBridgeId, sle2ErpsProfileControlName
}
STATUS current
DESCRIPTION
"destoryPhyRing"
::= { sle2ErpsProfileNotification 2 }
sle2ErpsProfileTimerChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName,
sle2ErpsProfileHoldOffTime, sle2ErpsProfileGuardTime, sle2ErpsProfileWaitToRestore }
STATUS current
DESCRIPTION
"setProfileTimer"
::= { sle2ErpsProfileNotification 3 }
sle2ErpsProfileNoneRevertiveChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsProfileControlRequest, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlTimeStamp, sle2ErpsProfileBridgeId, sle2ErpsProfileName,
sle2ErpsProfileNonRevertive }
STATUS current
DESCRIPTION
"setNoneRevertive"
::= { sle2ErpsProfileNotification 4 }
sle2ErpsInstance OBJECT IDENTIFIER ::= { sle2Erps 3 }
sle2ErpsInstanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sle2ErpsInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstance 1 }
sle2ErpsInstanceEntry OBJECT-TYPE
SYNTAX Sle2ErpsInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { sle2ErpsInstBridgeId, sle2ErpsInstName }
::= { sle2ErpsInstanceTable 1 }
Sle2ErpsInstanceEntry ::=
SEQUENCE {
sle2ErpsInstBridgeId
Integer32,
sle2ErpsInstName
OCTET STRING,
sle2ErpsInstPhyRingName
OCTET STRING,
sle2ErpsInstProfileName
OCTET STRING,
sle2ErpsInstRingId
Integer32,
sle2ErpsInstLevel
Integer32,
sle2ErpsInstRplRole
INTEGER,
sle2ErpsInstRplRolePort
INTEGER,
sle2ErpsInstSubRingBlock
INTEGER,
sle2ErpsInstCtrlVlan
Integer32,
sle2ErpsInstTafficVlans
OCTET STRING,
sle2ErpsInstChannelMode
INTEGER,
sle2ErpsInstVChannelVid
Integer32,
sle2ErpsInstVChannelAttachInstName
OCTET STRING,
sle2ErpsInstPropagateTc
INTEGER,
sle2ErpsInstActive
INTEGER,
sle2ErpsInstStatus
INTEGER,
sle2ErpsInstEastIfindex
Integer32,
sle2ErpsInstEastPortStatus
INTEGER,
sle2ErpsInstWestIfindex
Integer32,
sle2ErpsInstWestPortStatus
INTEGER,
sle2ErpsInstVersion
INTEGER,
sle2ErpsInstDataTrafficInheritanceInstName
OCTET STRING
}
sle2ErpsInstBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates primary bridgegroup id
1: default bridge id
100: backbone
"
::= { sle2ErpsInstanceEntry 1 }
sle2ErpsInstName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ERPS instance name."
::= { sle2ErpsInstanceEntry 2 }
sle2ErpsInstPhyRingName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical ring name (maximum 37 characters).
Indicates the sle2ErpsPhyRingName of sle2ErpsPhyRing table
"
::= { sle2ErpsInstanceEntry 3 }
sle2ErpsInstProfileName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Profile name (maximum 32 characters).
Indicates the sle2ErpsProfileName of sle2ErpsProfile Table.
"
::= { sle2ErpsInstanceEntry 4 }
sle2ErpsInstRingId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E>s ID"
::= { sle2ErpsInstanceEntry 5 }
sle2ErpsInstLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E>s Level"
::= { sle2ErpsInstanceEntry 6 }
sle2ErpsInstRplRole OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
owner(1),
neighbour(2),
nextNeighbor(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s Role"
::= { sle2ErpsInstanceEntry 7 }
sle2ErpsInstRplRolePort OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
east(1),
west(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring<6E>s RPL port"
::= { sle2ErpsInstanceEntry 8 }
sle2ErpsInstSubRingBlock OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
east(1),
west(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Sub-Ring<6E>s RPL port.
Indicates the Ring<6E>s interconnection port.
You should only give this command on interconnection nodes.
"
::= { sle2ErpsInstanceEntry 9 }
sle2ErpsInstCtrlVlan OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s control-vlan"
::= { sle2ErpsInstanceEntry 10 }
sle2ErpsInstTafficVlans OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s traffic-vlans"
::= { sle2ErpsInstanceEntry 11 }
sle2ErpsInstChannelMode OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
nonVirtualChannel(1),
virtualChannel(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceEntry 12 }
sle2ErpsInstVChannelVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN identifier"
::= { sle2ErpsInstanceEntry 13 }
sle2ErpsInstVChannelAttachInstName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Major instance name."
::= { sle2ErpsInstanceEntry 14 }
sle2ErpsInstPropagateTc OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceEntry 15 }
sle2ErpsInstActive OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceEntry 16 }
sle2ErpsInstStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
init(1),
pending(2),
idle(3),
foreced(4),
protected(5),
manual(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the erps instance status."
::= { sle2ErpsInstanceEntry 17 }
sle2ErpsInstEastIfindex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceEntry 18 }
sle2ErpsInstEastPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
unblocked(1),
blocked(2),
failed(3),
blockedFailed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the east interface status."
::= { sle2ErpsInstanceEntry 19 }
sle2ErpsInstWestIfindex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceEntry 20 }
sle2ErpsInstWestPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
unblocked(1),
blocked(2),
failed(3),
blockedFailed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the west interface status."
::= { sle2ErpsInstanceEntry 21 }
sle2ErpsInstVersion OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
version1(1),
version2(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the west interface erps version.
Version 1: ITU-T Recommendation G.8032/Y.1344 2008
Version 2: ITU-T Recommendation G.8032/Y.1344 2008
"
::= { sle2ErpsInstanceEntry 22 }
sle2ErpsInstDataTrafficInheritanceInstName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The inheritance ERPS instance name. (temporary)"
::= { sle2ErpsInstanceEntry 23 }
sle2ErpsInstanceControl OBJECT IDENTIFIER ::= { sle2ErpsInstance 2 }
sle2ErpsInstControlRequest OBJECT-TYPE
SYNTAX INTEGER
{
createErpsInstance(1),
destoryErpsInstance(2),
addErpsInstPhyRing(3),
delErpsInstPhyRing(4),
addErpsInstProfile(5),
delErpsInstProfile(6),
setErpsInstRingId(7),
setErpsInstLevel(8),
setErpsInstRpl(9),
addErpsInstSubRing(10),
delErpsInstSubRing(11),
addErpsInstCtrlVlan(12),
delErpsInstCtrlVlan(13),
addErpsInstTrafficVlan(14),
delErpsInstTrafficVlan(15),
addErpsInstVitrualChannel(16),
delErpsInstVitrualChannel(17),
addErpsInstNoneVirtualChanel(18),
delErpsInstNoneVirtualChanel(19),
setErpsInstForcedSwitch(20),
setErpsInstManualSwitch(21),
clearErpsInst(22),
setErpsInstPropagateTc(23),
setErpsInstVersion(24),
setErpsInstActive(25),
setVlanInheritanceDataTraffic(26),
delVlanInheritanceDataTraffic(27)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceControl 1 }
sle2ErpsInstControlStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceControl 2 }
sle2ErpsInstControlTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceControl 3 }
sle2ErpsInstControlTimeStamp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceControl 4 }
sle2ErpsInstControlReqResult OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceControl 5 }
sle2ErpsInstControlBridgeId OBJECT-TYPE
SYNTAX Integer32 (1..32 | 100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates primary bridgegroup id
1: default bridge id
100: backbone
"
::= { sle2ErpsInstanceControl 6 }
sle2ErpsInstControlName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ERPS instance name."
::= { sle2ErpsInstanceControl 7 }
sle2ErpsInstControlPhyRingName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physical ring name (maximum 37 characters).
Indicates the sle2ErpsPhyRingName of sle2ErpsPhyRing table
"
::= { sle2ErpsInstanceControl 8 }
sle2ErpsInstControlProfileName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile name (maximum 32 characters).
Indicates the sle2ErpsProfileName of sle2ErpsProfile Table.
"
::= { sle2ErpsInstanceControl 9 }
sle2ErpsInstControlRingId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring<6E>s ID"
::= { sle2ErpsInstanceControl 10 }
sle2ErpsInstControlLevel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring<6E>s Level"
::= { sle2ErpsInstanceControl 11 }
sle2ErpsInstControlRplRole OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
owner(1),
neighbour(2),
nextNeighbor(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s Role"
::= { sle2ErpsInstanceControl 12 }
sle2ErpsInstControlRplRolePort OBJECT-TYPE
SYNTAX INTEGER
{
east(1),
west(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring<6E>s RPL port"
::= { sle2ErpsInstanceControl 13 }
sle2ErpsInstControlSubRingBlock OBJECT-TYPE
SYNTAX INTEGER
{
east(1),
west(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Sub-Ring<6E>s RPL port.
Indicates the Ring<6E>s interconnection port.
You should only give this command on interconnection nodes.
"
::= { sle2ErpsInstanceControl 14 }
sle2ErpsInstControlCtrlVlan OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node<64>s control-vlan"
::= { sle2ErpsInstanceControl 15 }
sle2ErpsInstControlTafficVlans OBJECT-TYPE
SYNTAX Integer32 (2..4092)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Ring Node traffic-vlans"
::= { sle2ErpsInstanceControl 16 }
sle2ErpsInstControlVChannelVid OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN identifier"
::= { sle2ErpsInstanceControl 17 }
sle2ErpsInstControlVChannelAttachInstName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Major instance name."
::= { sle2ErpsInstanceControl 18 }
sle2ErpsInstControlForcedSwitch OBJECT-TYPE
SYNTAX INTEGER
{
east(1),
west(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Forced Switch"
::= { sle2ErpsInstanceControl 19 }
sle2ErpsInstControlManualSwitch OBJECT-TYPE
SYNTAX INTEGER
{
east(1),
west(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the Manual Switch"
::= { sle2ErpsInstanceControl 20 }
sle2ErpsInstControlPropagateTc OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceControl 21 }
sle2ErpsInstControlVersion OBJECT-TYPE
SYNTAX INTEGER
{
version1(1),
version2(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the version.
Version 0: ITU-T Recommendation G.8032/Y.1344 2008
Version 1: ITU-T Recommendation G.8032/Y.1344 2008
"
::= { sle2ErpsInstanceControl 22 }
sle2ErpsInstControlActive OBJECT-TYPE
SYNTAX INTEGER
{
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceControl 23 }
sle2ErpsInstControlDataTrafficInheritanceInstName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The inheritance ERPS instance name. (temporary)"
::= { sle2ErpsInstanceControl 24 }
sle2ErpsInstanceNotification OBJECT IDENTIFIER ::= { sle2ErpsInstance 3 }
sle2ErpsInstCreated NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName
}
STATUS current
DESCRIPTION
"createErpsInstance"
::= { sle2ErpsInstanceNotification 1 }
sle2ErpsInstDestoryed NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
}
STATUS current
DESCRIPTION
"destoryErpsInstance
"
::= { sle2ErpsInstanceNotification 2 }
sle2ErpsInstPhyRingAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstPhyRingName }
STATUS current
DESCRIPTION
"setErpsPhyRing"
::= { sle2ErpsInstanceNotification 3 }
sle2ErpsInstPhyRingDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
}
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceNotification 4 }
sle2ErpsInstProfileAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstProfileName }
STATUS current
DESCRIPTION
"setErpsProfile"
::= { sle2ErpsInstanceNotification 5 }
sle2ErpsInstProfileDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
}
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceNotification 6 }
sle2ErpsInstRingIdChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstRingId }
STATUS current
DESCRIPTION
"setErpsInstRingId"
::= { sle2ErpsInstanceNotification 7 }
sle2ErpsInstLevelChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstLevel }
STATUS current
DESCRIPTION
"setErpsInstLevel"
::= { sle2ErpsInstanceNotification 8 }
sle2ErpsInstRplRoleChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstRplRole, sle2ErpsInstRplRolePort }
STATUS current
DESCRIPTION
"setErpsInstRpl"
::= { sle2ErpsInstanceNotification 9 }
sle2ErpsInstSubRingAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstSubRingBlock }
STATUS current
DESCRIPTION
"addErpsInstRubRing"
::= { sle2ErpsInstanceNotification 10 }
sle2ErpsInstSubRingDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
}
STATUS current
DESCRIPTION
"delErpsInstRubRing"
::= { sle2ErpsInstanceNotification 11 }
sle2ErpsInstCtrlVlanAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstCtrlVlan }
STATUS current
DESCRIPTION
"addErpsInstCtrlVlan"
::= { sle2ErpsInstanceNotification 12 }
sle2ErpsInstCtrlVlanDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
sle2ErpsInstControlCtrlVlan }
STATUS current
DESCRIPTION
"delErpsInstCtrlVlan"
::= { sle2ErpsInstanceNotification 13 }
sle2ErpsInstDataTrafficVlanAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstTafficVlans }
STATUS current
DESCRIPTION
"addErpsInstTrafficVlan"
::= { sle2ErpsInstanceNotification 14 }
sle2ErpsInstDataTrafficVlanDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
sle2ErpsInstControlTafficVlans }
STATUS current
DESCRIPTION
"delErpsInstTrafficVlan"
::= { sle2ErpsInstanceNotification 15 }
sle2ErpsInstVitrualChannelAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstVChannelVid, sle2ErpsInstVChannelAttachInstName, sle2ErpsInstChannelMode }
STATUS current
DESCRIPTION
"setErpsInstVitrualChannel"
::= { sle2ErpsInstanceNotification 16 }
sle2ErpsInstVitrualChannelDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
}
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceNotification 17 }
sle2ErpsInstNoneVirtualChannelAdded NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstChannelMode }
STATUS current
DESCRIPTION
"setErpsInstNoneVirtualChanel"
::= { sle2ErpsInstanceNotification 18 }
sle2ErpsInstNoneVirtualChannelDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName
}
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceNotification 19 }
sle2ErpsInstForcedSwichChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
sle2ErpsInstControlForcedSwitch }
STATUS current
DESCRIPTION
"setErpsInstForcedSwitch"
::= { sle2ErpsInstanceNotification 20 }
sle2ErpsInstManualSwichChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlBridgeId, sle2ErpsInstControlName,
sle2ErpsInstControlManualSwitch }
STATUS current
DESCRIPTION
"setErpsInstManualSwitch"
::= { sle2ErpsInstanceNotification 21 }
sle2ErpsInstClearChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName
}
STATUS current
DESCRIPTION
"setErpsInstClear"
::= { sle2ErpsInstanceNotification 22 }
sle2ErpsInstPropagateTcChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstPropagateTc }
STATUS current
DESCRIPTION
"setErpsInstPropagateTc"
::= { sle2ErpsInstanceNotification 23 }
sle2ErpInstVersionChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstEastVersion, sle2ErpsInstWestVersion }
STATUS current
DESCRIPTION
"setErpsInstVersion"
::= { sle2ErpsInstanceNotification 24 }
sle2ErpInstActiveChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstActive }
STATUS current
DESCRIPTION
"Description."
::= { sle2ErpsInstanceNotification 25 }
sle2ErpInstDataTrafficInheritanceInstNameChanged NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstDataTrafficInheritanceInstName, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId,
sle2ErpsInstName }
STATUS current
DESCRIPTION
"Temp"
::= { sle2ErpsInstanceNotification 26 }
sle2ErpInstDataTrafficInheritanceInstNameDeleted NOTIFICATION-TYPE
OBJECTS { sle2ErpsInstControlRequest, sle2ErpsInstControlReqResult, sle2ErpsInstDataTrafficInheritanceInstName, sle2ErpsInstControlTimeStamp, sle2ErpsInstBridgeId,
sle2ErpsInstName }
STATUS current
DESCRIPTION
"Temp"
::= { sle2ErpsInstanceNotification 27 }
sleFaultMgmtGroup OBJECT-GROUP
OBJECTS { sleFaultDefaultSeverity, sleFaultCriteriaSeverity, sleFaultNotifiyActivity, sleFaultControlRequest, sleFaultControlStatus,
sleFaultControlTimer, sleFaultControlTimeStamp, sleFaultControlReqResult, sleFaultControlDefaultSeverity, sleFaultControlCriteriaSeverity,
sleFaultControlNotifiyActivity, sleAlarmSeverityIndex, sleAlarmSeverityValue, sleAlarmSeverityControlRequest, sleAlarmSeverityControlStatus,
sleAlarmSeverityControlTimer, sleAlarmSeverityControlTimeStamp, sleAlarmSeverityControlReqResult, sleAlarmSeverityControlIndex, sleAlarmSeverityControlValue,
sleAlarmSpecificCode, sleAlarmReportingSourceType, sleAlarmReportingSource, sleAlarmSpecificSeverity, sleAlarmSpecificProblem,
sleAlarmSpecificProblemText, sleAlarmTimeAndDate, sleAlarmHistoryIndex, sleAlarmHistorySpecific, sleAlarmHistorySeverity,
sleAlarmHistoryText, sleAlarmHistoryTime, sleAlarmHistoryControlRequest, sleAlarmHistoryControlStatus, sleAlarmHistoryControlTimer,
sleAlarmHistoryControlTimeStamp, sleAlarmHistoryControlReqResult, sleOamPortIndex, sleOamMuxAction, sleOamParAction,
sleOamAdminState, sleOamMode, sleOamUnidirectionMode, sleOamFunctionsSupported, sleOamPeerStatus,
sleOamPeerMacAddress, sleOamPeerMode, sleOamPeerFunctionsSupported, sleOamRemLoopback, sleOamControlRequest,
sleOamControlStatus, sleOamControlTimer, sleOamControlTimeStamp, sleOamControlReqResult, sleOamControlIndex,
sleOamControlPortAdminState, sleOamControlPortMode, sleOamControlPortUnidirectionMode, sleOamControlPortRemLoopback, sleAdvaFSPOperationMode,
sleAdvaActiveNetworkInterface, sleAdvaForceNetworkInterface, sleAdvaReportingInterval, sleAdvaNEMIFitted, sleAdvaForceReset,
sleAdvaManagerAddress, sleAdvaMinRailVoltageThreshold, sleAdvaMaxRailVoltageThreshold, sleAdvaTemperatureThreshold, sleAdvaPartNumber,
sleAdvaSerialNumber, sleAdvaFirmwareVersion, sleAdvaFPGAVersion, sleAdvaHardwareRevision, sleAdvaCLEICode,
sleAdvaTemperature, sleAdvaRailVoltage, sleAdvaPSUStates, sleAdvaPSUType, sleAdvaFansFitted,
sleAdvaFanState, sleAdvaTransmitMode, sleAdvaSystemControlRequest, sleAdvaSystemControlStatus, sleAdvaSystemControlTimer,
sleAdvaSystemControlTimeStamp, sleAdvaSystemControlReqResult, sleAdvaSystemControlPortIndex, sleAdvaSystemControlFSPOperationMode, sleAdvaSystemControlForceNetworkInterface,
sleAdvaSystemControlReportingInterval, sleAdvaSystemControlForceReset, sleAdvaSystemControlMinRailVoltageThreshold, sleAdvaSystemControlMaxRailVoltageThreshold, sleAdvaSystemControlTemperatureThreshold,
sleAdvaSystemControlTransmitMode, sleAdvaRemInstance, sleAdvaOperationalStatus, sleAdvaLineSpeed, sleAdvaMACAddress,
sleAdvaConnectorType, sleAdvaAutonegiotation, sleAdvaLinkLossForwarding, sleAdvaAdminState, sleAdvaRemoteInterfaceIndex,
sleAdvaUserDefinedString, sleAdvaRemoteSignalling, sleAdvaConfiguration, sleAdvaLocalTechnologyAbility, sleAdvaAdvertisedTechnologyAbility,
sleAdvaReceivedTechnologyAbility, sleAdvaLocalSectorAbility, sleAdvaAdvertisedSectorAbility, sleAdvaReceivedSectorAbility, sleAdvaDuplexCapabilities,
sleAdvaPHYType, sleAdvaPHYTypeList, sleAdvaMIIDetect, sleAdvaPHYState, sleAdvaGoodFramesTransmitted,
sleAdvaSingleCollisionFrames, sleAdvaMultipleCollisionFrames, sleAdvaGoodFramesReceived, sleAdvaFCSErrors, sleAdvaAlignmentErrors,
sleAdvaFramesTooLong, sleAdvaBytesTransmitted, sleAdvaBytesReceived, sleAdvaSymbolErrors, sleAdvaGeneralControlRequest,
sleAdvaGeneralControlStatus, sleAdvaGeneralControlTimer, sleAdvaGeneralControlTimeStamp, sleAdvaGeneralControlReqResult, sleAdvaGeneralControlPortIndex,
sleAdvaGeneralControlRemInstance, sleAdvaGeneralControlLineSpeed, sleAdvaGeneralControlAutonegiotation, sleAdvaGeneralControlLinkLossForwarding, sleAdvaGeneralControlUserDefinedString,
sleAdvaGeneralControlAdvertisedTechnologyAbility, sleAdvaGeneralControlAdvertisedSectorAbility, sleAdvaModuleType, sleAdvaModulePartNumber, sleAdvaModuleSerialNumber,
sleAdvaModuleFirmwareVersion, sleAdvaModuleSoftwareVersion, sleAdvaModuleHardwareRevision, sleAdvaModuleCLEICode, sleAdvaOpticalThresholdLevel,
sleAdvaLinkLength1, sleAdvaLinkLength2, sleAdvaLinkLength3, sleAdvaLinkLength4, sleAdvaLinkLengthCu,
sleAdvaWaveLength, sleAdvaLaserBias, sleAdvaTransmitPower, sleAdvaReceivePower, sleAdvaLaserTxTemperature,
sleAdvaOpticalControlRequest, sleAdvaOpticalControlStatus, sleAdvaOpticalControlTimer, sleAdvaOpticalControlTimeStamp, sleAdvaOpticalControlReqResult,
sleAdvaOpticalControlPortIndex, sleAdvaOpticalControlRemInstance, sleAdvaOpticalControlThresholdLevel, sleAdvaAdminStatus, sleAdvaMode,
sleAdvaRemMACAddress, sleAdvaRemConfig, sleAdvaRemPduConfig, sleAdvaLocFlags, sleAdvaRemFlags,
sleAdvaRemState, sleAdvaRemVendorOUI, sleAdvaRemDeviceNumber, sleAdvaRemVendorVersion, sleAdvaLocErrSymbolPeriodEventConfig,
sleAdvaLocErrFrameEventConfig, sleAdvaLocErrFramePeriodEventConfig, sleAdvaLocErrFrameSecsSummaryEventConfig, sleAdvaPDUsTx, sleAdvaPDUsRx,
sleAdvaUnsupportedCodesRx, sleAdvaInfoPDUsTx, sleAdvaInfoPDUsRx, sleAdvaEventNotificationPDUsTx, sleAdvaUniqueEventNotificationPDUsTx,
sleAdvaDupEventNotificationPDUsTx, sleAdvaLoopbackControlPDUsTx, sleAdvaLoopbackControlPDUsRx, sleAdvaVariableRequestPDUsTx, sleAdvaVariableRequestPDUsRx,
sleAdvaVariableResponsePDUsTx, sleAdvaVariableResponsePDUsRx, sleAdvaVendorPDUsTx, sleAdvaVendorPDUsRx, sleAdvaRemFramesLostDuetoOAMErr,
sleAdvaLocErrSymbolPeriodEvent, sleAdvaLocErrFrameSecsEvent, sleAdvaLocErrFramePeriodEvent, sleAdvaLocErrFrameSecsSummaryEvent, sleAdvaRemErrSymbolPeriodEvent,
sleAdvaRemErrFrameSecsEvent, sleAdvaRemoteErrorFramePeriodEvent, sleAdvaRemoteErrorFrameSecsSummaryEvent, sleAdvaOamControlRequest, sleAdvaOamControlStatus,
sleAdvaOamControlTimer, sleAdvaOamControlTimeStamp, sleAdvaOamControlReqResult, sleAdvaOamControlPortIndex, sleAdvaOamControlRemInstance,
sleAdvaOamControlAdminStatus, sleAlarmHistorySeqNum, sleAlarmSpecificSeqNum, sleFaultNextSeqNum, sleAlarmLEDType,
sleAlarmLEDStatus, sleAlarmLEDLevel, sleAlarmLEDLevelIndex, sleAlarmLEDLevelBlock, sleAlarmLEDControlRequest,
sleAlarmLEDControlStatus, sleAlarmLEDControlTimer, sleAlarmLEDControlTimeStamp, sleAlarmLEDControlReqResult, sleAlarmLEDControlType,
sleAlarmLEDControlLevel, sleAlarmLEDControlBlock, sleAlarmLEDLevelOperStatus, sleY1731Enable, sleY1731TrunkEnable,
sleY1731LtrCacheHoldTime, sleY1731LtrCacheSize, sleY1731SnmpServerTraps, sleY1731XcheckStartDelay, sleY1731DefaultMegLevel,
sleY1731DefaultMegMhfCreation, sleY1731PduToCfm, sleY1731DedicatedVlan, sleY1731BaseControlRequest, sleY1731BaseControlStatus,
sleY1731BaseControlTimer, sleY1731BaseControlTimeStamp, sleY1731BaseControlReqResult, sleY1731BaseControlEnable, sleY1731BaseControlTrunkEnable,
sleY1731BaseControlLtrCacheHoldTime, sleY1731BaseControlLtrCacheSize, sleY1731BaseControlSnmpServerTraps, sleY1731BaseControlXcheckStartDelay, sleY1731BaseControlDefaultMegLevel,
sleY1731BaseControlDefaultMegMhfCreation, sleY1731BaseControlPduToCfm, sleY1731BaseControlDedicatedVlan, sleY1731MegIndex, sleY1731MegName,
sleY1731MegLevel, sleY1731MegVid, sleY1731MegMepEnable, sleY1731MegCcEnable, sleY1731MegCcInterval,
sleY1731MegCcPriority, sleY1731MegCcLossThreshold, sleY1731MegCcHoldTime, sleY1731MegFaultPriority, sleY1731MegFaultKeepTime,
sleY1731MegFaultClearTime, sleY1731MegXcheckEnable, sleY1731MegAisEnable, sleY1731MegAisTransmitEnable, sleY1731MegAisInterval,
sleY1731MegAisLevel, sleY1731MegAisPriority, sleY1731MegLckEnable, sleY1731MegLckTransmitEnable, sleY1731MegLckInterval,
sleY1731MegLckLevel, sleY1731MegLckPriority, sleY1731MegOutOfService, sleY1731MegRapsEnable, sleY1731MegRapsRplOwner,
sleY1731MegRapsEastPort, sleY1731MegRapsWestPort, sleY1731MegRapsRplPort, sleY1731MegRapsHoldOffTime, sleY1731MegRapsGuardTime,
sleY1731MegRapsWaitToRestore, sleY1731MegRapsState, sleY1731MegControlRequest, sleY1731MegControlStatus, sleY1731MegControlTimer,
sleY1731MegControlTimeStamp, sleY1731MegControlReqResult, sleY1731MegControlIndex, sleY1731MegControlName, sleY1731MegControlLevel,
sleY1731MegControlVid, sleY1731MegControlMepEnable, sleY1731MegControlCcEnable, sleY1731MegControlCcInterval, sleY1731MegControlCcPriority,
sleY1731MegControlCcLossThreshold, sleY1731MegControlCcHoldTime, sleY1731MegControlFaultPriority, sleY1731MegControlFaultKeepTime, sleY1731MegControlFaultClearTime,
sleY1731MegControlXcheckEnable, sleY1731MegControlAisEnable, sleY1731MegControlAisTransmitEnable, sleY1731MegControlAisInterval, sleY1731MegControlAisLevel,
sleY1731MegControlAisPriority, sleY1731MegControlLckEnable, sleY1731MegControlLckTransmitEnable, sleY1731MegControlLckInterval, sleY1731MegControlLckLevel,
sleY1731MegControlLckPriority, sleY1731MegControlOutOfService, sleY1731MegControlRapsEnable, sleY1731MegControlRapsRplOwner, sleY1731MegControlRapsEastPort,
sleY1731MegControlRapsWestPort, sleY1731MegControlRapsRplPort, sleY1731MegControlRapsHoldOffTime, sleY1731MegControlRapsGuardTime, sleY1731MegControlRapsWaitToRestore,
sleY1731MepIdentifier, sleY1731MepIfIndex, sleY1731MepDirection, sleY1731MepEnable, sleY1731MepFngState,
sleY1731MepCcEnable, sleY1731MepMacAddress, sleY1731MepFaultPriority, sleY1731MepFaultKeepTime, sleY1731MepFaultClearTime,
sleY1731MepHighestPrDefect, sleY1731MepAisEnable, sleY1731MepAisTransmitEnable, sleY1731MepLckEnable, sleY1731MepLckTransmitEnable,
sleY1731MepOutOfService, sleY1731MepDlmEnabledRmep, sleY1731MepDefects, sleY1731MepCcmSequenceErrors, sleY1731MepCciSentCcms,
sleY1731MepNextLbmTransId, sleY1731MepLbrIn, sleY1731MepLbrInOutOfOrder, sleY1731MepTstLbrInBitError, sleY1731MepTstLbrInCrcError,
sleY1731MepLtmNextSeqNumber, sleY1731MepUnexpLtrIn, sleY1731MepLbrOut, sleY1731MepTmLbrFirstLostId, sleY1731MepTmLbrMaxRate,
sleY1731MepCcmFrameLossNearMin, sleY1731MepCcmFrameLossNearMax, sleY1731MepCcmFrameLossNearSum, sleY1731MepCcmFrameLossFarMin, sleY1731MepCcmFrameLossFarMax,
sleY1731MepCcmFrameLossFarSum, sleY1731MepControlRequest, sleY1731MepControlStatus, sleY1731MepControlTimer, sleY1731MepControlTimeStamp,
sleY1731MepControlReqResult, sleY1731MepControlIdentifier, sleY1731MepControlMegIndex, sleY1731MepControlIfIndex, sleY1731MepControlDirection,
sleY1731MepControlEnable, sleY1731MepControlCcEnable, sleY1731MepControlFaultPriority, sleY1731MepControlFaultKeepTime, sleY1731MepControlFaultClearTime,
sleY1731MepControlAisEnable, sleY1731MepControlAisTransmitEnable, sleY1731MepControlLckEnable, sleY1731MepControlLckTransmitEnable, sleY1731MepControlOutOfService,
sleY1731MepControlDlmEnabledRmep, sleY1731MepControlTransmitLbmIsUnicast, sleY1731MepControlTransmitLbmDestMacAddress, sleY1731MepControlTransmitLbmDestMepId, sleY1731MepControlTransmitLbmDestIsMepId,
sleY1731MepControlTransmitLbmCount, sleY1731MepControlTransmitLbmInterval, sleY1731MepControlTransmitLbmTimeout, sleY1731MepControlTransmitLbmPriority, sleY1731MepControlTransmitLbmLength,
sleY1731MepControlTransmitLtmTargetMacAddress, sleY1731MepControlTransmitLtmTargetMepId, sleY1731MepControlTransmitLtmTargetIsMepId, sleY1731MepControlTransmitLtmFlags, sleY1731MepControlTransmitLtmTtl,
sleY1731MepControlTransmitLtmPriority, sleY1731MepControlTransmitTstLbmDestMepId, sleY1731MepControlTransmitTstLbmDuration, sleY1731MepControlTransmitTstLbmInterval, sleY1731MepControlTransmitTstLbmTimeout,
sleY1731MepControlTransmitTstLbmPriority, sleY1731MepControlTransmitTstLbmLength, sleY1731MepControlTransmitTstLbmPattern, sleY1731MepControlTransmitTmLbmDestMepId, sleY1731MepControlTransmitTmLbmDuration,
sleY1731MepControlTransmitTmLbmPartDuration, sleY1731MepControlTransmitTmLbmStartRate, sleY1731MepControlTransmitTmLbmIncRate, sleY1731MepControlTransmitTmLbmTimeout, sleY1731MepControlTransmitTmLbmPriority,
sleY1731MepControlTransmitTmLbmLength, sleY1731MepControlTransmitTmLbmPattern, sleY1731MepControlTransmitTstIsUnicast, sleY1731MepControlTransmitTstDestMepId, sleY1731MepControlTransmitTstDuration,
sleY1731MepControlTransmitTstInterval, sleY1731MepControlTransmitTstPriority, sleY1731MepControlTransmitTstLength, sleY1731MepControlTransmitTstPattern, sleY1731MepControlReceiveTstDuration,
sleY1731MepControlTransmitTmTstIsUnicast, sleY1731MepControlTransmitTmTstDestMepId, sleY1731MepControlTransmitTmTstDuration, sleY1731MepControlTransmitTmTstPartDuration, sleY1731MepControlTransmitTmTstStartRate,
sleY1731MepControlTransmitTmTstIncRate, sleY1731MepControlTransmitTmTstTimeout, sleY1731MepControlTransmitTmTstPriority, sleY1731MepControlTransmitTmTstLength, sleY1731MepControlTransmitTmTstPattern,
sleY1731MepControlReceiveTmTstDuration, sleY1731MepControlTransmitLmmIsUnicast, sleY1731MepControlTransmitLmmDestMepId, sleY1731MepControlTransmitLmmDuration, sleY1731MepControlTransmitLmmInterval,
sleY1731MepControlTransmitLmmTimeout, sleY1731MepControlTransmitLmmPriority, sleY1731MepControlTransmit1dmIsUnicast, sleY1731MepControlTransmit1dmDestMepId, sleY1731MepControlTransmit1dmDuration,
sleY1731MepControlTransmit1dmInterval, sleY1731MepControlTransmit1dmPriority, sleY1731MepControlReceive1dmDuration, sleY1731MepControlTransmitDmmIsUnicast, sleY1731MepControlTransmitDmmDestMepId,
sleY1731MepControlTransmitDmmDuration, sleY1731MepControlTransmitDmmInterval, sleY1731MepControlTransmitDmmTimeout, sleY1731MepControlTransmitDmmPriority, sleY1731MipPort,
sleY1731MipLevel, sleY1731MipType, sleY1731MipControlRequest, sleY1731MipControlStatus, sleY1731MipControlTimer,
sleY1731MipControlTimeStamp, sleY1731MipControlReqResult, sleY1731MipControlPort, sleY1731MipControlLevel, sleY1731XcheckMepIdentifier,
sleY1731XcheckMepState, sleY1731XcheckControlRequest, sleY1731XcheckControlStatus, sleY1731XcheckControlTimer, sleY1731XcheckControlTimeStamp,
sleY1731XcheckControlReqResult, sleY1731XcheckControlMepIdentifier, sleY1731XcheckControlMegIndex, sleY1731CcMacAddress, sleY1731CcMacControlRequest,
sleY1731CcMacControlStatus, sleY1731CcMacControlTimer, sleY1731CcMacControlTimeStamp, sleY1731CcMacControlReqResult, sleY1731CcMacControlMegIndex,
sleY1731CcMacControlMepIdentifier, sleY1731CcMacControlAddress, sleY1731AisMacAddress, sleY1731AisMacControlRequest, sleY1731AisMacControlStatus,
sleY1731AisMacControlTimer, sleY1731AisMacControlTimeStamp, sleY1731AisMacControlReqResult, sleY1731AisMacControlMegIndex, sleY1731AisMacControlMepIdentifier,
sleY1731AisMacControlAddress, sleY1731LckMacAddress, sleY1731LckMacControlRequest, sleY1731LckMacControlStatus, sleY1731LckMacControlTimer,
sleY1731LckMacControlTimeStamp, sleY1731LckMacControlReqResult, sleY1731LckMacControlMegIndex, sleY1731LckMacControlMepIdentifier, sleY1731LckMacControlAddress,
sleY1731RmepIdentifier, sleY1731RmepState, sleY1731RmepFailedOkTime, sleY1731RmepMacAddress, sleY1731RmepIfIndex,
sleY1731RmepRdi, sleY1731RmepLoc, sleY1731RmepReceiveTstCount, sleY1731RmepReceiveTstOutOfOrder, sleY1731RmepReceiveTstBitError,
sleY1731RmepReceiveTstCrcError, sleY1731RmepReceiveTmTstCount, sleY1731RmepReceiveTmTstLostId, sleY1731RmepLmrFrameLossNearMin, sleY1731RmepLmrFrameLossNearMax,
sleY1731RmepLmrFrameLossNearSum, sleY1731RmepLmrFrameLossFarMin, sleY1731RmepLmrFrameLossFarMax, sleY1731RmepLmrFrameLossFarSum, sleY1731RmepReceive1dmCount,
sleY1731Rmep1dmFrameDelayMin, sleY1731Rmep1dmFrameDelayMax, sleY1731Rmep1dmFrameDelayAvg, sleY1731Rmep1dmFrameDelayVar, sleY1731RmepReceiveDmrCount,
sleY1731RmepDmrFrameDelayMin, sleY1731RmepDmrFrameDelayMax, sleY1731RmepDmrFrameDelayAvg, sleY1731RmepDmrFrameDelayVar, sleY1731LbrReceiveOrder,
sleY1731LbrRemoteMacAddress, sleY1731LtrSeqNumber, sleY1731LtrReceiveOrder, sleY1731LtrForwarded, sleY1731LtrTerminalMep,
sleY1731LtrLastEgressIdentifier, sleY1731LtrNextEgressIdentifier, sleY1731LtrRelay, sleY1731LtrIngress, sleY1731LtrIngressMac,
sleY1731LtrIngressPort, sleY1731LtrEgress, sleY1731LtrEgressMac, sleY1731LtrEgressPort, sleY1731ConfigErrorVid,
sleY1731ConfigErrorIfIndex, sleY1731ConfigErrorType, sleY1731MipCcdbIndex, sleY1731MipCcdbVlanId, sleY1731MipCcdbMacAddr,
sleY1731MipCcdbPort, sleY1731MipCcdbKeepTime, sleY1731RmepCreation, sleY1731BaseControlRmepCreation, sleY1731BaseControlTrunkIndex,
sleY1731BaseControlTrunkOamStatus, sleY1731TrunkIndex, sleY1731TrunkOamStatus, sleY1731BaseControlTrunkMeg, sleY1731TrunkMeg,
sleY1731MepLbSuccessRate, sleY1731MepTmLbmCount, sleY1731MepTmLbrCount, sleY1731MepTmTstCount, sleY1731RmepControlRequest,
sleY1731RMepControlStatus, sleY1731RmepControlTimer, sleY1731RmepControlTimeStamp, sleY1731RmepControlReqResult, sleY1731RmepControlIdentifier,
sleY1731RmepControlMegIndex, sleY1731RmepControlIfIndex, sleY1731MegRapsEastPortStatus, sleY1731MegRapsWestPortStatus, sleY1731MegRapsNonRevertive,
sleY1731MegRapsForcedSwitchEast, sleY1731MegRapsForcedSwitchWest, sleY1731MegControlRapsNonRevertive, sleY1731MegControlRapsForcedSwitchEast, sleY1731MegControlRapsForcedSwitchWest,
sleY1731URMegName, sleY1731URDedicatedVlan, sleY1731UREnableStatus, sleY1731URConnectivityCheckMeg, sleY1731URPrimaryMepId,
sleY1731URSecondaryMepId, sleY1731URControlVlan, sleY1731URNodeConf, sleY1731URNodeConfPortNum, sleY1731URNonRevertive,
sleY1731URTrustMemberCount, sleY1731URWaitToRestore, sleY1731URControlRequest, sleY1731URControlStatus, sleY1731URControlTimer,
sleY1731URControlTimeStamp, sleY1731URControlReqResult, sleY1731URControlMegName, sleY1731URControlDedicatedVlan, sleY1731URControlEnableStatus,
sleY1731URControlConnectivityCheckMeg, sleY1731URControlPrimaryMepId, sleY1731URControlSecondaryMepId, sleY1731URControlControlVlan, sleY1731URControlNodeConf,
sleY1731URControlNodeConfPortNum, sleY1731URControlNonRevertive, sleY1731URControlTrustMemberCount, sleY1731URControlWaitToRestore, sleY1731URMegIndex,
sleY1731URControlMegIndex, sleY1731URNodeConfPortStatus, sleY1731CCIgnoreDefect, sleY1731RapsFloodingBlock, sleY1731BaseControlCCIgnoreDefect,
sleY1731BaseControlRapsFloodingBlock, sleEMLogDisableStatus, sleEMLogAction, sleEMLogInterval, sleEMLogControlRequest,
sleEMLogControlStatus, sleEMLogControlTimer, sleEMLogControlTimeStamp, sleEMLogControlReqResult, sleEMLogControlDisableStatus,
sleEMLogControlAction, sleEMLogControlInterval, sleY1731MepLbRoundtripMin, sleY1731MepLbRoundtripMax, sleY1731MepLbRoundtripAvg,
sleCfmEnable, sleCfmLtrCacheHoldTime, sleCfmLtrCacheSize, sleCfmSnmpServerTraps, sleCfmXcheckStartDelay,
sleCfmBaseControlRequest, sleCfmBaseControlStatus, sleCfmBaseControlTimer, sleCfmBaseControlTimeStamp, sleCfmBaseControlReqResult,
sleCfmBaseControlEnable, sleCfmBaseControlLtrCacheHoldTime, sleCfmBaseControlLtrCacheSize, sleCfmBaseControlSnmpServerTraps, sleCfmBaseControlXcheckStartDelay,
sleCfmBaseControlTrunkIndex, sleCfmBaseControlTrunkMdName, sleCfmBaseControlTrunkMaVid, sleCfmTrunkIndex, sleCfmTrunkMdName,
sleCfmTrunkMaVid, sleCfmMdIndex, sleCfmMdName, sleCfmMdLevel, sleCfmMdMepEnable,
sleCfmMdCcEnable, sleCfmMdCcInterval, sleCfmMdCcPriority, sleCfmMdCcLossThreshold, sleCfmMdCcHoldTime,
sleCfmMdFaultPriority, sleCfmMdFaultKeepTime, sleCfmMdFaultClearTime, sleCfmMdXcheckEnable, sleCfmMdControlRequest,
sleCfmMdControlStatus, sleCfmMdControlTimer, sleCfmMdControlTimeStamp, sleCfmMdControlReqResult, sleCfmMdControlIndex,
sleCfmMdControlName, sleCfmMdControlLevel, sleCfmMdControlMepEnable, sleCfmMdControlCcEnable, sleCfmMdControlCcInterval,
sleCfmMdControlCcPriority, sleCfmMdControlCcLossThreshold, sleCfmMdControlCcHoldTime, sleCfmMdControlFaultPriority, sleCfmMdControlFaultKeepTime,
sleCfmMdControlFaultClearTime, sleCfmMdControlXcheckEnable, sleCfmMaIndex, sleCfmMaName, sleCfmMaVid,
sleCfmMaMepEnable, sleCfmMaCcEnable, sleCfmMaCcInterval, sleCfmMaCcPriority, sleCfmMaCcLossThreshold,
sleCfmMaCcFaultPriority, sleCfmMaCcFaultKeepTime, sleCfmMaCcFaultClearTime, sleCfmMaXcheckEnable, sleCfmMaControlRequest,
sleCfmMaControlStatus, sleCfmMaControlTimer, sleCfmMaControlTimeStamp, sleCfmMaControlReqResult, sleCfmMaControlIndex,
sleCfmMaControlName, sleCfmMaControlVid, sleCfmMaControlMdIndex, sleCfmMaControlMepEnable, sleCfmMaControlCcEnable,
sleCfmMaControlCcInterval, sleCfmMaControlCcPriority, sleCfmMaControlCcLossThreshold, sleCfmMaControlFaultPriority, sleCfmMaControlFaultKeepTime,
sleCfmMaControlFaultClearTime, sleCfmMaControlXcheckEnable, sleCfmMepIdentifier, sleCfmMepIfIndex, sleCfmMepDirection,
sleCfmMepEnable, sleCfmMepFngState, sleCfmMepCcEnable, sleCfmMepMacAddress, sleCfmMepCcPriority,
sleCfmMepFaultPriority, sleCfmMepFaultKeepTime, sleCfmMepFaultClearTime, sleCfmMepHighestPrDefect, sleCfmMepDefects,
sleCfmMepCciSentCcms, sleCfmMepNextLbmTransId, sleCfmMepLbrIn, sleCfmMepLbrInOutOfOrder, sleCfmMepLtmNextSeqNumber,
sleCfmMepUnexpLtrIn, sleCfmMepControlRequest, sleCfmMepControlStatus, sleCfmMepControlTimer, sleCfmMepControlTimeStamp,
sleCfmMepControlReqResult, sleCfmMepControlIdentifier, sleCfmMepControlMdIndex, sleCfmMepControlMaIndex, sleCfmMepControlIfIndex,
sleCfmMepControlDirection, sleCfmMepControlEnable, sleCfmMepControlCcEnable, sleCfmMepControlCcPriority, sleCfmMepControlFaultPriority,
sleCfmMepControlFaultKeepTime, sleCfmMepControlFaultClearTime, sleCfmMepControlTransmitLbmDestMacAddress, sleCfmMepControlTransmitLbmDestMepId, sleCfmMepControlTransmitLbmDestIsMepId,
sleCfmMepControlTransmitLbmCount, sleCfmMepControlTransmitLbmInterval, sleCfmMepControlTransmitLbmTimeout, sleCfmMepControlTransmitLbmPriority, sleCfmMepControlTransmitLtmTargetMacAddress,
sleCfmMepControlTransmitLtmTargetMepId, sleCfmMepControlTransmitLtmTargetIsMepId, sleCfmMepControlTransmitLtmFlags, sleCfmMepControlTransmitLtmTtl, sleCfmMipPort,
sleCfmMipLevel, sleCfmMipType, sleCfmMipControlRequest, sleCfmMipControlStatus, sleCfmMipControlTimer,
sleCfmMipControlTimeStamp, sleCfmMipControlReqResult, sleCfmMipControlPort, sleCfmMipControlLevel, sleCfmXcheckMepIdentifier,
sleCfmXcheckMepState, sleCfmXcheckControlRequest, sleCfmXcheckControlStatus, sleCfmXcheckControlTimer, sleCfmXcheckControlTimeStamp,
sleCfmXcheckControlReqResult, sleCfmXcheckControlMepIdentifier, sleCfmXcheckControlMdIndex, sleCfmXcheckControlMaIndex, sleCfmRmepIdentifier,
sleCfmRmepState, sleCfmRmepMacAddress, sleCfmRmepIfIndex, sleCfmRmepRdi, sleCfmRmepPortStatus,
sleCfmRmepInterfaceStatus, sleCfmLtrSeqNumber, sleCfmLtrReceiveOrder, sleCfmLtrTtl, sleCfmLtrForwarded,
sleCfmLtrTerminalMep, sleCfmLtrLastEgressIdentifier, sleCfmLtrNextEgressIdentifier, sleCfmLtrRelay, sleCfmLtrIngress,
sleCfmLtrIngressMac, sleCfmLtrIngressPort, sleCfmLtrEgress, sleCfmLtrEgressMac, sleCfmLtrEgressPort,
sleCfmConfigErrorVid, sleCfmConfigErrorIfIndex, sleCfmConfigErrorType, sleCfmMipCcdbIndex, sleCfmMipCcdbVlanId,
sleCfmMipCcdbMacAddr, sleCfmMipCcdbPort, sleCfmMipCcdbKeepTime, sleRapsRingId, sleRapsRingType,
sleRapsRingLevel, sleRapsRingCtrlVlan, sleRapsRingTrafficVlans, sleRapsRingNodeId, sleRapsRingEnable,
sleRapsRingBridgeRole, sleRapsRingState, sleRapsRingEastPort, sleRapsRingEastPortStatus, sleRapsRingWestPort,
sleRapsRingWestPortStatus, sleRapsRingRplPort, sleRapsRingIcPort, sleRapsRingMultipleFailure, sleRapsRingPropagateTc,
sleRapsRingNonRevertive, sleRapsRingForcedSwitch, sleRapsRingHoldOffTime, sleRapsRingGuardTime, sleRapsRingWaitToRestore,
sleRapsRingWaitToBlock, sleRapsRingControlRequest, sleRapsRingControlStatus, sleRapsRingControlTimer, sleRapsRingControlTimeStamp,
sleRapsRingControlReqResult, sleRapsRingControlId, sleRapsRingControlType, sleRapsRingControlLevel, sleRapsRingControlCtrlVlan,
sleRapsRingControlTrafficVlans, sleRapsRingControlEnable, sleRapsRingControlEastPort, sleRapsRingControlWestPort, sleRapsRingControlBridgeRole,
sleRapsRingControlMultipleFailure, sleRapsRingControlPropagateTc, sleRapsRingControlNonRevertive, sleRapsRingControlHoldOffTime, sleRapsRingControlGuardTime,
sleRapsRingControlWaitToRestore, sleRapsRingControlWaitToBlock, sleY1731LbrTransId, sleY1731LbrRoundTripTime, sleY1731TlvPermission,
sleY1731BaseControlTlvPermission, sleY1731MepPmEnable, sleY1731MepCcmFrameLossNearRatio, sleY1731MepCcmFrameLossNearAvgRatio, sleY1731MepCcmFrameLossFarRatio,
sleY1731MepCcmFrameLossFarAvgRatio, sleY1731MepControlPmEnable, sleY1731RmepLmrFrameLossNearRatio, sleY1731RmepLmrFrameLossNearAvgRatio, sleY1731RmepLmrFrameLossFarRatio,
sleY1731RmepLmrFrameLossFarAvgRatio, sleY1731URSFCondition, sleY1731URControlSFCondition, sleAdvaOamControlMode, sleAlarmReportControlRequest,
sleAlarmReportControlStatus, sleAlarmReportControlTimer, sleAlarmReportControlTimeStamp, sleAlarmReportControlReqResult, sleY1731URForceSwitch,
sleY1731URControlForceSwitch, sleEMLogDefectCPUHigh, sleEMLogTemperHigh, sleEMLogTemperLow, sleEMLogMemLow,
sleEMLogFanFail, sleEMLogPhyCRCFail, sleEMLogPhyDetectFail, sleEMLogSFUMateInitFail, sleEMLogDaemonHealthBad,
sleY1731LtrTtl, sleY1731LRMepIndex, sleY1731LRMepDMegIndex, sleY1731LRMepDMepIdentifier, sleY1731LRMepDRmepIdentifier,
sleY1731LRMepControlRequest, sleY1731LRMepControlStatus, sleY1731LRMepControlTimer, sleY1731LRMepControlTimeStamp, sleY1731LRMepControlReqResult,
sleY1731LRMepControlMegIndex, sleY1731LRMepControlMepIdentifier, sleY1731LRMepControlRmepIdentifier, sleY1731LRMepControlDMegIndex, sleY1731LRMepControlDMepIdentifier,
sleY1731LRMepControlDRmepIdentifier, sleEMLogGPIURavenLinkDown, sleY1731MepRllcfGuardTime, sleY1731MepControlRllcfGuardTime, sleOamRemLoopbackCnt,
sleOamLm, sleOamLmAction, sleOamLmFrameWindow, sleOamLmFrameThresh, sleOamLmFrameTotal,
sleOamLmFramePeriodWindow, sleOamLmFramePeriodThresh, sleOamLmFramePeriodTotal, sleOamLmFrameSecondSummaryWindow, sleOamLmFrameSecondSummaryThresh,
sleOamLmFrameSecondSummaryTotal, sleOamLmSymbolPeriodWindow, sleOamLmSymbolPeriodThresh, sleOamLmSymbolPeriodTotal, sleOamLmRemSeqNum,
sleOamLmRemFrameLength, sleOamLmRemFrameTimeStamp, sleOamLmRemFrameWindow, sleOamLmRemFrameThresh, sleOamLmRemFrameErrors,
sleOamLmRemFrameErrorRunTotal, sleOamLmRemFrameEventRunTotal, sleOamLmRemFramePeriodLength, sleOamLmRemFramePeriodTimeStamp, sleOamLmRemFramePeriodWindow,
sleOamLmRemFramePeriodThresh, sleOamLmRemFramePeriodErrors, sleOamLmRemFramePeriodErrorRunTotal, sleOamLmRemFramePeriodEventRunTotal, sleOamLmRemFrameSecondSummaryLength,
sleOamLmRemFrameSecondSummaryTimeStamp, sleOamLmRemFrameSecondSummaryWindow, sleOamLmRemFrameSecondSummaryThresh, sleOamLmRemFrameSecondSummaryErrors, sleOamLmRemFrameSecondSummaryErrorRunTotal,
sleOamLmRemFrameSecondSummaryEventRunTotal, sleOamLmRemSymbolPeriodLength, sleOamLmRemSymbolPeriodTimeStamp, sleOamLmRemSymbolPeriodWindow, sleOamLmRemSymbolPeriodThresh,
sleOamLmRemSymbolPeriodErrors, sleOamLmRemSymbolPeriodErrorRunTotal, sleOamLmRemSymbolPeriodEventRunTotal, sleOamControlRemLoopbackPkCnt, sleOamControlLm,
sleOamControlLmAction, sleOamControlLmFrameWindow, sleOamControlLmFrameThresh, sleOamControlLmFramePeriodWindow, sleOamControlLmFramePeriodThresh,
sleOamControlLmFrameSecondSummaryWindow, sleOamControlLmFrameSecondSummaryThresh, sleOamControlLmSymbolPeriodWindow, sleOamControlLmSymbolPeriodThresh, sleY1731LtrRoundTripTime,
sleY1731MepRllcf, sleY1731MepRllcfHoldOff, sleY1731MepControlRllcf, sleY1731MepControlRllcfHoldOff, sleRapsRingInstId,
sleRapsRingChannel, sleRapsRingPassThrough, sleRapsRingManualSwitch, sleRapsRingVerifiedTime, sleRapsRingControlInstId,
sleRapsRingVirtualVlan, sleRapsRingIcNode, sleY1731URTrafficVlan, sleY1731URState, sleY1731URControlTrafficVlan,
sleAlarmReportPairType, sleAlarmHistoryPairType, sleY1731URManualSwitch, sleY1731URControlManualSwitch, sleEMLogNAKLockStatus,
sleEMLogNakCompensate, sleEMLogRecoverActionMemLow, sleEMLogRecoverActionNak, sleEMLogControlNAKLockStatus, sleEMLogControlNAKCompensate,
sleEMLogControlRecoverActionMemLow, sleEMLogControlRecoverActionNAK, sleEMLogNAK, sleFaultMonitorGlobalInspectInterval, sleFaultMonitorGlobalStartupThreshold,
sleFaultMonitorGlobalNoKeepalive, sleFaultMonitorGlobalControlRequest, sleFaultMonitorGlobalControlStatus, sleFaultMonitorGlobalControlTimer, sleFaultMonitorGlobalControlTimeStamp,
sleFaultMonitorGlobalControlReqResult, sleFaultMonitorGlobalControlInspectInterval, sleFaultMonitorGlobalControlStartupThreshold, sleFaultMonitorGlobalControlNoKeepalive, sleFaultMonitorDaemonName,
sleFaultMonitorDaemonPid, sleFaultMonitorDaemonAdminStatus, sleFaultMonitorDaemonCrashAction, sleFaultMonitorDaemonTimeoutAction, sleFaultMonitorDaemonThreshold,
sleFaultMonitorDaemonThresholded, sleFaultMonitorDaemonStartupThresholded, sleFaultMonitorDaemonWatchdogAdminStatus, sleFaultMonitorDaemonWatchdogThreshold, sleFaultMonitorDaemonWatchdogCount,
sleFaultMonitorDaemonControlRequest, sleFaultMonitorDaemonControlStatus, sleFaultMonitorDaemonControlTimer, sleFaultMonitorDaemonControlTimeStamp, sleFaultMonitorDaemonControlReqResult,
sleFaultMonitorDaemonControlAdminStatus, sleFaultMonitorDaemonControlCrashAction, sleFaultMonitorDaemonControlTimeoutAction, sleFaultMonitorDaemonControlThreshold, sleFaultMonitorDaemonControlWatchdogAdminStatus,
sleFaultMonitorDaemonControlWatchdogThreshold, sleFaultMonitor2pointsLinearAdminStatus, sleFaultMonitor2pointsLinearInterval, sleFaultMonitor2pointsLinearThreshold, sleFaultMonitor2pointsLinearControlRequest,
sleFaultMonitor2pointsLinearControlStatus, sleFaultMonitor2pointsLinearControlTimer, sleFaultMonitor2pointsLinearControlTimeStamp, sleFaultMonitor2pointsLinearControlReqResult, sleFaultMonitor2pointsLinearControlAdminStatus,
sleFaultMonitor2PonitsLinearControlInterval, sleFaultMonitor2PointsLinearControlThreshold, sleFaultMonitorRHMAdminStatus, sleFaultMonitorRHMActionType, sleFaultMonitorRHMActionThreshold,
sleFaultMonitorRHMRebootThreshold, sleFaultMonitorRHMRecoveryTime, sleFaultMonitorRHMFaultCounter, sleFaultMonitorRHMRebootCounter, sleFaultMonitorRHMHostAddr,
sleFaultMonitorRHMControlRequest, sleFaultMonitorRHMControlStatus, sleFaultMonitorRHMControlTimer, sleFaultMonitorRHMControlTimeStamp, sleFaultMonitorRHMControlReqResult,
sleFaultMonitorRHMControlAdminStatus, sleFaultMonitorRHMControlActionType, sleFaultMonitorRHMControlActionThreshold, sleFaultMonitorRHMControlRebootThreshold, sleFaultMonitorRHMControlRecoveryTime,
sleFaultMonitorRHMControlHostAddr, sleEMLogFANRPMLow, sleFaultMonitorRHMInterval, sleFaultMonitorRHMLiveThreshold, sleFaultMonitorRHMControlInterval,
sleFaultMonitorRHMControlLiveThreshold, sleY1731MegMd, sleY1731MegControlMd, sleFaultMonitorDaemonControlName, sleFaultMonitorDaemonControlThreshed,
sleFaultMonitorDaemonControlStartupThresh, sleAlarmReportControlSpecificCode, sleAlarmReportControlSourceType, sleAlarmReportControlSource, sle2EthCfmEnable,
sle2EthCfmLmmFrameCountSimStatus, sle2EthCfmControlRequest, sle2EthCfmControlStatus, sle2EthCfmControlTimer, sle2EthCfmControlTimeStamp,
sle2EthCfmControlReqResult, sle2EthCfmControlEnable, sle2EthCfmControlLmmFrameCountSimStatus, sle2EthCfmBridgeId, sle2EthCfmBridgeDefaultMdLevel,
sle2EthCfmBridgeDefaultMepId, sle2EthCfmBridgeAutomatic, sle2EthCfmBridgeConfigDefaultMdLevel, sle2EthCfmBridgeConfigDefaultMdMipCreation, sle2EthCfmBridgeLtrCacheEnable,
sle2EthCfmBridgeLtrCacheSize, sle2EthCfmBridgeControlRequest, sle2EthCfmBridgeControlStatus, sle2EthCfmBridgeControlTimer, sle2EthCfmBridgeControlTimeStamp,
sle2EthCfmBridgeControlReqResult, sle2EthCfmBridgeControlId, sle2EthCfmBridgeControlDefaultMdLevel, sle2EthCfmBridgeControlDefaultMepId, sle2EthCfmBridgeControlAutomatic,
sle2EthCfmBridgeControlConfigDefaultMdLevel, sle2EthCfmBridgeControlConfigDefaultMdMipCreation, sle2EthCfmBridgeConntrolLtrCacheEnable, sle2EthCfmBridgeControlLtrCacheSize, sle2EthCfmVlanConfigPrimaryVid,
sle2EthCfmVlanConfigSecondaryVid, sle2EthCfmVlanConfigSecondaryBridgeId, sle2EthCfmVlanConfigControlRequest, sle2EthCfmVlanConfigControlStatus, sle2EthCfmVlanConfigControlTimer,
sle2EthCfmVlanConfigControlTimeStamp, sle2EthCfmVlanConfigControlReqResult, sle2EthCfmVlanConfigControlPrimaryBridgeId, sle2EthCfmVlanConfigControlPrimaryVid, sle2EthCfmVlanConfigControlSecondaryBridgeId,
sle2EthCfmVlanConfigControlSecondaryVid, sle2EthCfmVlanInfoVid, sle2EthCfmVlanInfoPriority, sle2EthCfmVlanInfoControlRequest, sle2EthCfmVlanInfoControlStatus,
sle2EthCfmVlanInfoControlTimer, sle2EthCfmVlanInfoControlTimeStamp, sle2EthCfmVlanInfoControlReqResult, sle2EthCfmVlanInfoControlBridgeId, sle2EthCfmVlanInfoControlVid,
sle2EthCfmVlanInfoControlPriority, sle2EthCfmDefMdLevelEntryVid, sle2EthCfmDefMdLevelEntryLevel, sle2EthCfmDefMdLevelEntryMipCreation, sle2EthCfmDefMdLevelEntryControlRequest,
sle2EthCfmDefMdLevelEntryControlStatus, sle2EthCfmDefMdLevelEntryControlTimer, sle2EthCfmDefMdLevelEntryControlTimeStamp, sle2EthCfmDefMdLevelEntryControlReqResult, sle2EthCfmDefMdLevelEntryControlBridgeId,
sle2EthCfmDefMdLevelEntryControlVid, sle2EthCfmDefMdLevelEntryControlLevel, sle2EthCfmDefMdLevelEntryControlMipCreation, sle2EthCfmMdName, sle2EthCfmMdType,
sle2EthCfmMdLevel, sle2EthCfmMdMipCreation, sle2EthCfmMdControlRequest, sle2EthCfmMdControlStatus, sle2EthCfmMdControlTimer,
sle2EthCfmMdControlTimeStamp, sle2EthCfmMdControlReqResult, sle2EthCfmMdControlBridgeId, sle2EthCfmMdControlType, sle2EthCfmMdControlName,
sle2EthCfmMdControlLevel, sle2EthCfmMdControlMipCreation, sle2EthCfmMaName, sle2EthCfmMaVid, sle2EthCfmMaType,
sle2EthCfmMaMipCreation, sle2EthCfmMaCcInterval, sle2EthCfmMaElmi, sle2EthCfmMaConnectivityStatus, sle2EthCfmMaConfiguredRmepCount,
sle2EthCfmMaConvergedRmepCount, sle2EthCfmMaControlRequest, sle2EthCfmMaControlStatus, sle2EthCfmMaControlTimer, sle2EthCfmMaControlTimeStamp,
sle2EthCfmMaControlReqResult, sle2EthCfmMaControlBridgeId, sle2EthCfmMaControlMdName, sle2EthCfmMaControlName, sle2EthCfmMaControlType,
sle2EthCfmMaControlVid, sle2EthCfmMaControlMipCreation, sle2EthCfmMaControlCcmInterval, sle2EthCfmMaControlElmi, sle2EthCfmMepInfoId,
sle2EthCfmMepInfoIfindex, sle2EthCfmMepInfoLocalVid, sle2EthCfmMepInfoDirection, sle2EthCfmMepInfoActive, sle2EthCfmMepInfoUNI,
sle2EthCfmMepInfoCcmStatus, sle2EthCfmMepInfoCcmType, sle2EthCfmMepInfoCcmRmepId, sle2EthCfmMepInfoLocalMacAddr, sle2EthCfmMepInfoRdi,
sle2EthCfmMepInfoService, sle2EthCfmMepInfoLckLevel, sle2EthCfmMepInfoConnectivityStatus, sle2EthCfmMepInfoControlRequest, sle2EthCfmMepInfoControlStatus,
sle2EthCfmMepInfoControlTimer, sle2EthCfmMepInfoControlTimeStamp, sle2EthCfmMepInfoControlReqResult, sle2EthCfmMepInfoControlBridgeId, sle2EthCfmMepInfoControlMdName,
sle2EthCfmMepInfoControlMaVid, sle2EthCfmMepInfoControlIfindex, sle2EthCfmMepInfoControlId, sle2EthCfmMepInfoControlLocalVid, sle2EthCfmMepInfoControlMepDirection,
sle2EthCfmMepInfoControlActive, sle2EthCfmMepInfoControlUNI, sle2EthCfmMepInfoControlCcmStatus, sle2EthCfmMepInfoControlFrameType, sle2EthCfmMepInfoControlRmepId,
sle2EthCfmMepInfoControlService, sle2EthCfmMepInfoControlLckLevel, sle2EthCfmMepInfoControlTstPattern, sle2EthCfmMepInfoControlTstRecursive, sle2EthCfmMepInfoControlTstTxInterval,
sle2EthCfmMepInfoControlTstLckInterval, sle2EthCfmMepInfoControlLckRmepId, sle2EthCfmMepAttrActive, sle2EthCfmMepAttrCcmLtmPriority, sle2EthCfmMepAttrLowPrDef,
sle2EthCfmMepAttrFngAlarmTime, sle2EthCfmMepAttrResetFngTime, sle2EthCfmMepAttrCcmLtmFlag, sle2EthCfmMepAttrTxLtmTargetMac, sle2EthCfmMepAttrTxLtmTargetMepId,
sle2EthCfmMepAttrTxLtmTargetIsMepId, sle2EthCfmMepAttrTxLtmTtl, sle2EthCfmMepAttrTxLtmEgressId, sle2EthCfmMepAttrTxLbmStatus, sle2EthCfmMepAttrTxLbmDestMac,
sle2EthCfmMepAttrTxLbmDestMepId, sle2EthCfmMepAttrTxLbmDestIsMepId, sle2EthCfmMepAttrTxLbmMessages, sle2EthCfmMepAttrTxLbmDataTlv, sle2EthCfmMepAttrTxLbmVlanPriority,
sle2EthCfmMepAttrTxLbmVlanDropEnable, sle2EthCfmMepAttrTxLbmTimeOut, sle2EthCfmMepAttrLbrTimeOut, sle2EthCfmMepAttrControlRequest, sle2EthCfmMepAttrControlStatus,
sle2EthCfmMepAttrControlTimer, sle2EthCfmMepAttrControlTimeStamp, sle2EthCfmMepAttrControlReqResult, sle2EthCfmMepAttrControlBridgeId, sle2EthCfmMepAttrControlMdName,
sle2EthCfmMepAttrControlMaVid, sle2EthCfmMepAttrControlMepId, sle2EthCfmMepAttrControlActive, sle2EthCfmMepAttrControlCcmLtmPriority, sle2EthCfmMepAttrContrlLowPrDef,
sle2EthCfmMepAttrContrlFngAlarmTime, sle2EthCfmMepAttrControlResetFngTime, sle2EthCfmMepAttrControlCcmLtmFlag, sle2EthCfmMepAttrControlTxLtmTargetMac, sle2EthCfmMepAttrControlTxLtmTargetMepId,
sle2EthCfmMepAttrControlTxLtmTargetIsMepId, sle2EthCfmMepAttrControlTxLtmTtl, sle2EthCfmMepAttrControlTxLtmEgressId, sle2EthCfmMepAttrControlTxLbmStatus, sle2EthCfmMepAttrControlTxLbmDestMacAddress,
sle2EthCfmMepAttrControlTxLbmDestMepId, sle2EthCfmMepAttrControlTxLbmDestIsMepId, sle2EthCfmMepAttrControlTxLbmMessages, sle2EthCfmMepAttrControlTxLbmDataTlv, sle2EthCfmMepAttrControlTxLbmVlanPriority,
sle2EthCfmMepAttrControlTxLbmVlanDropEnable, sle2EthCfmMepAttrControlTxLbmTimeOut, sle2EthCfmMepAttrControlLbrTimeOut, sle2EthCfmXcheckRmepId, sle2EthCfmXcheckRmepMac,
sle2EthCfmXcheckControlRequest, sle2EthCfmXcheckControlStatus, sle2EthCfmXcheckControlTimer, sle2EthCfmXcheckControlTimeStamp, sle2EthCfmXcheckControlReqResult,
sle2EthCfmXcheckControlBridgeId, sle2EthCfmXcheckControlMdName, sle2EthCfmXcheckControlMaVid, sle2EthCfmXcheckControlRmepId, sle2EthCfmXcheckControlRmepMac,
sle2EthCfmLbReceivedCount, sle2EthCfmLbRemoteMacAddress, sle2EthCfmLbTxMessages, sle2EthCfmLbResponseCount, sle2EthCfmLbControlRequest,
sle2EthCfmLbControlStatus, sle2EthCfmLbControlTimer, sle2EthCfmLbControlTimeStamp, sle2EthCfmLbControlReqResult, sle2EthCfmLbControlBridgeId,
sle2EthCfmLbControlMdName, sle2EthCfmLbControlMaVid, sle2EthCfmLbControlMepId, sle2EthCfmLbControlMdLevel, sle2EthCfmLbControlRmepId,
sle2EthCfmLbControlRmepMac, sle2EthCfmLbControlTlvData, sle2EthCfmLbControlTlvTest, sle2EthCfmLbControlRecursive, sle2EthCfmLtrMepMac,
sle2EthCfmLtrHops, sle2EthCfmLtrRelay, sle2EthCfmLtrIngressEgress, sle2EthCfmLtrIngress, sle2EthCfmLtrEgress,
sle2EthCfmLtControlRequest, sle2EthCfmLtControlStatus, sle2EthCfmLtControlTimer, sle2EthCfmLtControlTimeStamp, sle2EthCfmLtControlReqResult,
sle2EthCfmLtControlBridgeId, sle2EthCfmLtControlMdName, sle2EthCfmLtControlMaVid, sle2EthCfmLtControlLevel, sle2EthCfmLtControlRmepMac,
sle2EthCfmAisInfoStatus, sle2EthCfmAisInfoDefectConditions, sle2EthCfmAisInfoLevel, sle2EthCfmAisInfoFrameType, sle2EthCfmAisInfoRmepMac,
sle2EthCfmAisInfoInterval, sle2EthCfmAisInfoReceivedDefectConditions, sle2EthCfmAisInfoLastReceivedDefectCondition, sle2EthCfmAisInfoControlRequest, sle2EthCfmAisInfoControlStatus,
sle2EthCfmAisInfoControlTimer, sle2EthCfmAisInfoControlTimeStamp, sle2EthCfmAisInfoControlReqResult, sle2EthCfmAisInfoControlBridgeId, sle2EthCfmAisInfoControlMdName,
sle2EthCfmAisInfoControlMaVid, sle2EthCfmAisInfoControlMepId, sle2EthCfmAisInfoControlEnable, sle2EthCfmAisInfoControlDefectConditions, sle2EthCfmAisInfoControlLevel,
sle2EthCfmAisInfoControlFrameType, sle2EthCfmAisInfoControlRmepMac, sle2EthCfmAisInfoControlInterval, sle2EthCfmSrvAisIfIndex, sle2EthCfmSrvAisEnable,
sle2EthCfmSrvAislevel, sle2EthCfmSrvAisInterval, sle2EthCfmSrvAisControlRequest, sle2EthCfmSrvAisControlStatus, sle2EthCfmSrvAisControlTimer,
sle2EthCfmSrvAisControlTimeStamp, sle2EthCfmSrvAisControlReqResult, sle2EthCfmSrvAisControlBridgeId, sle2EthCfmSrvAisControlIfIndex, sle2EthCfmSrvAisControlEnable,
sle2EthCfmSrvAisControlLevel, sle2EthCfmSrvAisControlInterval, sle2EthCfmLmmStatusRmepId, sle2EthCfmLmmStatusStartTime, sle2EthCfmLmmStatusCurrentTime,
sle2EthCfmLmmStatusEndTime, sle2EthCfmLmmStatusNeerLoss, sle2EthCfmLmmStatusFarLoss, sle2EthCfmLmmStatusCurNeerLoss, sle2EthCfmLmmStatusCurFarLoss,
sle2EthCfmRmepId, sle2EthCfmRempMepId, sle2EthCfmRmepLevel, sle2EthCfmRmepMaVid, sle2EthCfmRmepActiveState,
sle2EthCfmRmepRemoteMac, sle2EthCfmRmepRdi, sle2EthCfmRmepFlags, sle2EthCfmRmepControlRequest, sle2EthCfmRmepControlStatus,
sle2EthCfmRmepControlTimer, sle2EthCfmRmepControlTimeStamp, sle2EthCfmRmepControlReqResult, sle2EthCfmRmepControlBridgeId, sle2EthCfmRmepControlMdName,
sle2EthCfmRmepControlMdLevel, sle2EthCfmMipVid, sle2EthCfmMipMdLevel, sle2EthCfmMipIfindex, sle2EthCfmMipLocalMac,
sle2EthCfmStatCcmSent, sle2EthCfmStatCcmRevOutOfSeq, sle2EthCfmStatLbrSent, sle2EthCfmStatLbrRevValid, sle2EthCfmStatLbrRevBadMsdu,
sle2EthCfmStatLbrRevOutOfSeq, sle2EthCfmStatLtrRevUnexpected, sle2EthCfmAcitveLevelIfIndex, sle2EthCfmActiveLevelStatus, sle2EthCfmErrorIndex,
sle2EthCfmErrorMdLevel, sle2EthCfmErrorMaVid, sle2EthCfmErrorMepId, sle2EthCfmErrorRmepMac, sle2EthCfmErrorReason,
sle2EthCfmErrorServiceId, sle2EthCfmErrorControlRequest, sle2EthCfmErrorControlStatus, sle2EthCfmErrorControlTimer, sle2EthCfmErrorControlTimeStamp,
sle2EthCfmErrorControlReqResult, sle2EthCfmErrorControlBridgeId, sle2EthCfmErrorControlMdName, sle2EthCfmErrorControlMdLevel, sle2EthCfmLtCacheIndex,
sle2EthCfmLtCacheSrcMac, sle2EthCfmLtCacheHops, sle2EthCfmLtCacheRelay, sle2ErpsPhyRingBridgeId, sle2ErpsPhyRingName,
sle2ErpsPhyRingEastPort, sle2ErpsPhyRingWestPort, sle2ErpsPhyRingControlRequest, sle2ErpsPhyRingControlStatus, sle2ErpsPhyRingControlTimer,
sle2ErpsPhyRingControlTimeStamp, sle2ErpsPhyRingControlReqResult, sle2ErpsPhyRingControlBridgeId, sle2ErpsPhyRingControName, sle2ErpsPhyRingControEastPort,
sle2ErpsPhyRingControWestPort, sle2ErpsProfileBridgeId, sle2ErpsProfileName, sle2ErpsProfileHoldOffTime, sle2ErpsProfileGuardTime,
sle2ErpsProfileWaitToRestore, sle2ErpsProfileNonRevertive, sle2ErpsProfileControlRequest, sle2ErpsProfileControlStatus, sle2ErpsProfileControlTimer,
sle2ErpsProfileControlTimeStamp, sle2ErpsProfileControlReqResult, sle2ErpsProfileControlBridgeId, sle2ErpsProfileControlName, sle2ErpsProfileControlHoldOffTime,
sle2ErpsProfileControlGuardTime, sle2ErpsProfileControlWaitToRestore, sle2ErpsProfileControlNonRevertive, sle2ErpsInstBridgeId, sle2ErpsInstName,
sle2ErpsInstPhyRingName, sle2ErpsInstProfileName, sle2ErpsInstRingId, sle2ErpsInstLevel, sle2ErpsInstRplRole,
sle2ErpsInstRplRolePort, sle2ErpsInstSubRingBlock, sle2ErpsInstCtrlVlan, sle2ErpsInstTafficVlans, sle2ErpsInstVChannelVid,
sle2ErpsInstVChannelAttachInstName, sle2ErpsInstPropagateTc, sle2ErpsInstStatus, sle2ErpsInstEastPortStatus, sle2ErpsInstWestPortStatus,
sle2ErpsInstControlRequest, sle2ErpsInstControlStatus, sle2ErpsInstControlTimer, sle2ErpsInstControlTimeStamp, sle2ErpsInstControlReqResult,
sle2ErpsInstControlBridgeId, sle2ErpsInstControlName, sle2ErpsInstControlPhyRingName, sle2ErpsInstControlProfileName, sle2ErpsInstControlRingId,
sle2ErpsInstControlLevel, sle2ErpsInstControlRplRole, sle2ErpsInstControlRplRolePort, sle2ErpsInstControlSubRingBlock, sle2ErpsInstControlCtrlVlan,
sle2ErpsInstControlTafficVlans, sle2ErpsInstControlVChannelVid, sle2ErpsInstControlVChannelAttachInstName, sle2ErpsInstControlForcedSwitch, sle2ErpsInstControlManualSwitch,
sle2ErpsInstControlPropagateTc, sle2ErpsInstControlVersion, sleRapsRingControlIcNode, sleRapsRingControlChannel, sleRapsRingControlParamPort,
sleRapsRingControlPassThrough, sleRapsRingControlVerifiedTime, sle2EthCfmMepInfoDlmState, sle2EthCfmMepInfoDlmRmepId, sle2EthCfmMepInfoControlDlmState,
sle2EthCfmMepInfoControlDuration, sle2EthCfmMepInfoControlInterval, sle2EthCfmMepInfoControlTransMode, sle2EthCfmLbFrameType, sle2EthCfmLbControlTlvType,
sle2ErpsPhyRingEastMepId, sle2ErpsPhyRingEastRmepId, sle2ErpsPhyRingWestMepId, sle2ErpsPhyRingWestRmepId, sle2ErpsPhyRingControlMepId,
sle2ErpsPhyRingControlRmepId, sle2ErpsInstChannelMode, sle2ErpsInstActive, sle2ErpsInstEastIfindex, sle2ErpsInstWestIfindex,
sle2EthCfmMepInfoInterval, sle2ErpsInstControlActive, sle2EthCfmLtControlMepId, sle2ErpsInstVersion, sle2ErpsInstDataTrafficInheritanceInstName,
sle2ErpsInstControlDataTrafficInheritanceInstName }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMgmt 19 }
sleFaultMgmtNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { sleAlarmDefaultSeverityChanged, sleAlarmDefaultCriteriaChanged, sleNotificationActivityChanged, sleAlarmSeveriityCreated, sleAlarmSeveriityDestroyed,
sleAlarmSeverityChanged, sleAlarmReportNotified, sleAlarmHistoryCleared, sleEfmOamPortProfileChanged, sleEfmOamPortRemLoopback,
sleAdvaSystemProfileChanged, sleAdvaAlarmProfileChanged, sleAdvaElectricalInterfaceChanged, sleAdvaGeneralProfileChanged, sleAdvaAutonegProfileChanged,
sleAdvaOpticalAlarmChanged, sleAlarmLEDOffChanged, sleAlarmLEDLevelChanged, sleAlarmLEDCleared, sleAlarmLEDBlockChanged,
sleY1731EnableChanged, sleY1731TrunkEnableChanged, sleY1731LtrCacheProfileChanged, sleY1731SnmpProfileChanged, sleY1731XcheckProfileChanged,
sleY1731DefaultMegProfileChanged, sleY1731PduToCfmChanged, sleY1731DedicatedVlanChanged, sleY1731MipCcdbDestroyed, sleY1731LtrCacheDestroyed,
sleY1731MegCreated, sleY1731MegDeleted, sleY1731MegMepEnableChanged, sleY1731MegCcEnableChanged, sleY1731MegCcProfileChanged,
sleY1731MegFaultProfileChanged, sleY1731MegXcheckEnableChanged, sleY1731MegAisEnableChanged, sleY1731MegAisTransmitEnableChanged, sleY1731MegAisProfileChanged,
sleY1731MegLckEnableChanged, sleY1731MegLckTransmitEnableChanged, sleY1731MegLckProfileChanged, sleY1731MegOutOfServiceChanged, sleY1731MegRapsEnableChanged,
sleY1731MegRapsRingportsChanged, sleY1731MegRapsRplPortChanged, sleY1731MegRapsRplOwnerChanged, sleY1731MegRapsTimerChanged, sleY1731MegRemoteMepDestroyed,
sleY1731MegErrorDestroyed, sleY1731MepCreated, sleY1731MepDeleted, sleY1731MepEnableChanged, sleY1731MepCcEnableChanged,
sleY1731MepFaultProfileChanged, sleY1731MepAisEnableChanged, sleY1731MepAisTransmitEnableChanged, sleY1731MepLckEnableChanged, sleY1731MepLckTransmitEnableChanged,
sleY1731MepOutOfServiceChanged, sleY1731MepDlmEnableChanged, sleY1731MepTransmitLbmFinished, sleY1731MepTransmitLtmFinished, sleY1731MepTransmitTstLbmFinished,
sleY1731MepTransmitTmLbmFinished, sleY1731MepTransmitTstFinished, sleY1731MepReceiveTstFinished, sleY1731MepTransmitTmTstFinished, sleY1731MepReceiveTmTstFinished,
sleY1731MepTransmitLmmFinished, sleY1731MepTransmit1dmFinished, sleY1731MepReceive1dmFinished, sleY1731MepTransmitDmmFinished, sleY1731MipCreated,
sleY1731MipDeleted, sleY1731XcheckMepCreated, sleY1731XcheckMepDeleted, sleY1731CcMacCreated, sleY1731CcMacDeleted,
sleY1731AisMacCreated, sleY1731AisMacDeleted, sleY1731LckMacCreated, sleY1731LckMacDeleted, sleY1731RmepCreationChanged,
sleY1731TrunkOamStatusChanged, sleY1731RmepCreated, sleY1731RmepDeleted, sleY1731MegRapsNonRevertiveChanged, sleY1731MegRapsForcedSwitchEastChanged,
sleY1731MegRapsForcedSwitchWestChanged, sleY1731URDedicatedVlanChanged, sleY1731UREnableStatusChanged, sleY1731URCCPrimaryMepIdChanged, sleY1731URCCPrimaryMepIdCleared,
sleY1731URCCSecondaryMepIdChanged, sleY1731URCCSecondaryMepIdCleared, sleY1731URControlVlanChanged, sleY1731URNodeConfChanged, sleY1731URNodeConfCleared,
sleY1731URNonRevertiveChanged, sleY1731URTrustMemberCountChanged, sleY1731URTrustMemberCountCleared, sleY1731URWaitToRestoreChanged, sleY1731URWaitToRestoreCleared,
sleY1731URControlVlanCleared, sleY1731URForceSwitchChanged, sleY1731URManualSwitchChanged, sleY1731CCIgnoreDefectChanged, sleY1731RapsFloodinBlockChanged,
sleEMLogDisableStatusChanged, sleEMLogActionChanged, sleEMLogIntervalChanged, sleCfmEnableChanged, sleCfmLtrCacheProfileChanged,
sleCfmSnmpServerTrapsChanged, sleCfmXcheckStartDelayChanged, sleCfmMipCcdbDestroyed, sleCfmLtrCacheDestroyed, sleCfmTrunkPortCreated,
sleCfmTrunkPortDeleted, sleCfmMdCreated, sleCfmMdDeleted, sleCfmMdMepEnableChanged, sleCfmMdCcEnableChanged,
sleCfmMdCcProfileChanged, sleCfmMdFaultProfileChanged, sleCfmMdXcheckEnableChanged, sleCfmMdErrorDestoryed, sleCfmMdRmepDestoryed,
sleCfmMaCreated, sleCfmMaDeleted, sleCfmMaMepEnableChanged, sleCfmMaCcEnableChanged, sleCfmMaCcProfileChanged,
sleCfmMaFaultProfileChanged, sleCfmMaXcheckEnableChanged, sleCfmMepCreated, sleCfmMepDeleted, sleCfmMepEnableChanged,
sleCfmMepCcEnableChanged, sleCfmMepCcProfileChanged, sleCfmMepFaultProfileChanged, sleCfmMipCreated, sleCfmMipDeleted,
sleCfmXcheckMepCreated, sleCfmXcheckMepDeleted, sleRapsRingCreated, sleRapsRingDeleted, sleRapsRingEnableChanged,
sleRapsRingPortsCreated, sleRapsRingPortsDestroyed, sleRapsRingRplPortChanged, sleRapsRingMultipleFailureChanged, sleRapsRingPropagateTcChanged,
sleRapsRingNonRevertiveChanged, sleRapsRingForcedSwitchChanged, sleRapsRingManualSwitchChanged, sleRapsRingSwitchCleared, sleRapsRingHoldOffTimeChanged,
sleRapsRingGuardTimeChanged, sleRapsRingWtrTimeChanged, sleRapsRingWtbTimeChanged, sleY1731TlvPermissionChanged, sleY1731MepPmEnableChanged,
sleY1731LRMepCreated, sleY1731LRMEPDeleted, setAdvaOamProfileChanged, sleAlarmReportCleared, sleEfmOamPortLinkMonitorChanged,
sleRapsRingIcPortCreated, sleRapsRingIcPortDestroyed, sleY1731URTrafficVlanChanged, sleY1731URTrafficVlanCleared, sleEMLogNAKLockChanged,
sleEMLogNAKCompensateChanged, sleEMLogRecoverActionMemLowChanged, sleEMLogRecoverActionNAKChanged, setFaultMonitorGlobalInspectIntervalChanged, setFaultMonitorGlobalStartupThresholdChanged,
setFaultMonitorGlobalNoKeepaliveActionChanged, setFaultMonitorDaemonAdminStatusChanged, setFaultMonitorDaemonFaultActionChanged, setFaultMonitorDaemonThresholdChanged, setFaultMonitorDaemonWatchdogchanged,
sleFaultMonitor2PointsLinearAdminStatusChanged, sleFaultMonitor2PointsLinearIntervalChanged, sleFaultMonitor2PointsLinearThresholdChanged, setRHMStatusChanged, setRHMActionThresholdChanged,
setRHMRebootThresholdChanged, setRHMHostAdded, setRHMHostCleared, sleY1731MegMdAdded, sleY1731MegMdDeleted,
sleAlarmReportDeleted, sle2EthCfmEnableChanged, sle2EthCfmLmmFrameCountSimulatorChanged, setCfmBridgeProfile, setCfmBridgeLtrCacheEnable,
clearCfmBridgeLtrCache, setCfmBridgeAutomatic, setCfmBridgeConfigDefaultMdLevel, addCfmVlanConfVid, delCfmVlanConfVid,
sle2EthCfmVlanPriorityChanged, sle2EthCfmDefMdLevelEntryChanged, sle2EthCfmDefMdLevelEntryCleared, sle2EthCfmMdCreated, sle2EthCfmMdDestoryed,
sle2EthCfmMaCreated, sle2EthCfmMaDestoryed, sle2EthCfmCcIntervalChanged, sle2EthCfmElmiChanged, sle2EthCfmMepCreated,
sle2EthCfmMepDestory, sle2EthCfmCcEnableChanged, sle2EthCfmServiceChanged, sle2EthCfmTransmitUnicastTstFinished, sle2EthCfmTransmitMulticastTstFinished,
sle2EthCfmTransmitExmFinished, sle2EthCfmTransmitVsmFinished, sle2EthCfmTransmitMccFinished, sle2EthCfmMepFaultProfileChanged, sle2EthCfmMepTxLtmProfileChanged,
sle2EthCfmMepTxLbmProfileChanged, sle2EthCfmMepAuttributesAllCleared, sle2EthCfmXcheckMepCreated, sle2EthCfmXcheckMepDestoryed, sle2EthCfmLbTransmitMulticastFinished,
sle2EthCfmLbTransmitUnicastFinished, sle2EthCfmLbTransmitMacFinished, sle2EthCfmLbrFinished, sle2EthCfmLtTransmitDomainFinished, sle2EthCfmLtTransmitLevelFinished,
sle2EthCfmLtrFinished, sle2EthCfmAisInfoStatusChanged, sle2EthCfmAisInfoIntervalChanged, sle2EthCfmSrvAisChanged, sle2EthCfmRmepDomainCleared,
sle2EthCfmRmepLevelCleared, sle2EthCfmErrorDomainCleared, sle2EthCfmErrorLevelCleared, sle2ErpsPhyRingCreated, sle2ErpsPhyRingDestoryed,
sle2ErpsPhyRingEastPortAdded, sle2ErpsPhyRingEastPortDeleted, sle2ErpsPhyRingWestPortAdded, sle2ErpsPhyRingWestPortDeleted, sle2ErpsProfileCreated,
sle2ErpsProfileDestoryed, sle2ErpsProfileTimerChanged, sle2ErpsProfileNoneRevertiveChanged, sle2ErpsInstCreated, sle2ErpsInstDestoryed,
sle2ErpsInstRingIdChanged, sle2ErpsInstLevelChanged, sle2ErpsInstRplRoleChanged, sle2ErpsInstSubRingAdded, sle2ErpsInstSubRingDeleted,
sle2ErpsInstCtrlVlanAdded, sle2ErpsInstCtrlVlanDeleted, sle2ErpsInstDataTrafficVlanAdded, sle2ErpsInstDataTrafficVlanDeleted, sle2ErpsInstForcedSwichChanged,
sle2ErpsInstManualSwichChanged, sle2ErpsInstClearChanged, sle2ErpsInstPropagateTcChanged, sle2ErpInstVersionChanged, sle2ErpInstDataTrafficInheritanceInstNameChanged,
sle2ErpInstDataTrafficInheritanceInstNameDeleted, sleY1731URSFConditionChanged, sleY1731MepRllcfChanged, sleRapsRingChannelChanged, sleRapsRingPassThroughChanged,
sleRapsRingVrfTimeChanged, sle2EthCfmDualEndLmmChanged, sle2EthCfmTransmitUnicastLmFinished, sle2EthCfmTransmitMulticastLmFinished, sle2EthCfmTransmitUnicastDmFinished,
sle2EthCfmTransmitMuliticastDmFinished, sle2EthCfmReceive1DmFinished, sle2EthCfmTransmitTmFinished, sle2EthCfmReceiveTmFinished, sle2ErpsPhyRingEastMepIdAdded,
sle2ErpsPhyRingEastMepIdDeleted, sle2ErpsPhyRingWestMepIdAdded, sle2ErpsPhyRingWestMepIdDeleted, sle2ErpsInstPhyRingAdded, sle2ErpsInstPhyRingDeleted,
sle2ErpsInstProfileAdded, sle2ErpsInstProfileDeleted, sle2ErpsInstVitrualChannelAdded, sle2ErpsInstVitrualChannelDeleted, sle2ErpsInstNoneVirtualChannelAdded,
sle2ErpsInstNoneVirtualChannelDeleted, sle2ErpInstActiveChanged }
STATUS current
DESCRIPTION
"Description."
::= { sleFaultMgmt 20 }
END
--
-- sle-faultmgmt-mib.mib
--